Sample records for obtained results compared

  1. Comparing Results from Constant Comparative and Computer Software Methods: A Reflection about Qualitative Data Analysis

    ERIC Educational Resources Information Center

    Putten, Jim Vander; Nolen, Amanda L.

    2010-01-01

    This study compared qualitative research results obtained by manual constant comparative analysis with results obtained by computer software analysis of the same data. An investigated about issues of trustworthiness and accuracy ensued. Results indicated that the inductive constant comparative data analysis generated 51 codes and two coding levels…

  2. International normalized ratio (INR) testing in Europe: between-laboratory comparability of test results obtained by Quick and Owren reagents.

    PubMed

    Meijer, Piet; Kynde, Karin; van den Besselaar, Antonius M H P; Van Blerk, Marjan; Woods, Timothy A L

    2018-04-12

    This study was designed to obtain an overview of the analytical quality of the prothrombin time, reported as international normalized ratio (INR) and to assess the variation of INR results between European laboratories, the difference between Quick-type and Owren-type methods and the effect of using local INR calibration or not. In addition, we assessed the variation in INR results obtained for a single donation in comparison with a pool of several plasmas. A set of four different lyophilized plasma samples were distributed via national EQA organizations to participating laboratories for INR measurement. Between-laboratory variation was lower in the Owren group than in the Quick group (on average: 6.7% vs. 8.1%, respectively). Differences in the mean INR value between the Owren and Quick group were relatively small (<0.20 INR). Between-laboratory variation was lower after local INR calibration (CV: 6.7% vs. 8.6%). For laboratories performing local calibration, the between-laboratory variation was quite similar for the Owren and Quick group (on average: 6.5% and 6.7%, respectively). Clinically significant differences in INR results (difference in INR>0.5) were observed between different reagents. No systematic significant differences in the between-laboratory variation for a single-plasma sample and a pooled plasma sample were observed. The comparability for laboratories using local calibration of their thromboplastin reagent is better than for laboratories not performing local calibration. Implementing local calibration is strongly recommended for the measurement of INR.

  3. Comparison of Anaerobic Susceptibility Results Obtained by Different Methods

    PubMed Central

    Rosenblatt, J. E.; Murray, P. R.; Sonnenwirth, A. C.; Joyce, J. L.

    1979-01-01

    Susceptibility tests using 7 antimicrobial agents (carbenicillin, chloramphenicol, clindamycin, penicillin, cephalothin, metronidazole, and tetracycline) were run against 35 anaerobes including Bacteroides fragilis (17), other gram-negative bacilli (7), clostridia (5), peptococci (4), and eubacteria (2). Results in triplicate obtained by the microbroth dilution method and the aerobic modification of the broth disk method were compared with those obtained with an agar dilution method using Wilkins-Chalgren agar. Media used in the microbroth dilution method included Wilkins-Chalgren broth, brain heart infusion broth, brucella broth, tryptic soy broth, thioglycolate broth, and Schaedler's broth. A result differing by more than one dilution from the Wilkins-Chalgren agar result was considered a discrepancy, and when there was a change in susceptibility status this was termed a significant discrepancy. The microbroth dilution method using Wilkins-Chalgren broth and thioglycolate broth produced the fewest total discrepancies (22 and 24, respectively), and Wilkins-Chalgren broth, thioglycolate, and Schaedler's broth had the fewest significant discrepancies (6, 5, and 5, respectively). With the broth disk method, there were 15 significant discrepancies, although half of these were with tetracycline, which was the antimicrobial agent associated with the highest number of significant discrepancies (33), considering all of the test methods and media. PMID:464560

  4. Using Internet Search Engines to Obtain Medical Information: A Comparative Study

    PubMed Central

    Wang, Liupu; Wang, Juexin; Wang, Michael; Li, Yong; Liang, Yanchun

    2012-01-01

    Background The Internet has become one of the most important means to obtain health and medical information. It is often the first step in checking for basic information about a disease and its treatment. The search results are often useful to general users. Various search engines such as Google, Yahoo!, Bing, and Ask.com can play an important role in obtaining medical information for both medical professionals and lay people. However, the usability and effectiveness of various search engines for medical information have not been comprehensively compared and evaluated. Objective To compare major Internet search engines in their usability of obtaining medical and health information. Methods We applied usability testing as a software engineering technique and a standard industry practice to compare the four major search engines (Google, Yahoo!, Bing, and Ask.com) in obtaining health and medical information. For this purpose, we searched the keyword breast cancer in Google, Yahoo!, Bing, and Ask.com and saved the results of the top 200 links from each search engine. We combined nonredundant links from the four search engines and gave them to volunteer users in an alphabetical order. The volunteer users evaluated the websites and scored each website from 0 to 10 (lowest to highest) based on the usefulness of the content relevant to breast cancer. A medical expert identified six well-known websites related to breast cancer in advance as standards. We also used five keywords associated with breast cancer defined in the latest release of Systematized Nomenclature of Medicine-Clinical Terms (SNOMED CT) and analyzed their occurrence in the websites. Results Each search engine provided rich information related to breast cancer in the search results. All six standard websites were among the top 30 in search results of all four search engines. Google had the best search validity (in terms of whether a website could be opened), followed by Bing, Ask.com, and Yahoo!. The search

  5. Using Internet search engines to obtain medical information: a comparative study.

    PubMed

    Wang, Liupu; Wang, Juexin; Wang, Michael; Li, Yong; Liang, Yanchun; Xu, Dong

    2012-05-16

    The Internet has become one of the most important means to obtain health and medical information. It is often the first step in checking for basic information about a disease and its treatment. The search results are often useful to general users. Various search engines such as Google, Yahoo!, Bing, and Ask.com can play an important role in obtaining medical information for both medical professionals and lay people. However, the usability and effectiveness of various search engines for medical information have not been comprehensively compared and evaluated. To compare major Internet search engines in their usability of obtaining medical and health information. We applied usability testing as a software engineering technique and a standard industry practice to compare the four major search engines (Google, Yahoo!, Bing, and Ask.com) in obtaining health and medical information. For this purpose, we searched the keyword breast cancer in Google, Yahoo!, Bing, and Ask.com and saved the results of the top 200 links from each search engine. We combined nonredundant links from the four search engines and gave them to volunteer users in an alphabetical order. The volunteer users evaluated the websites and scored each website from 0 to 10 (lowest to highest) based on the usefulness of the content relevant to breast cancer. A medical expert identified six well-known websites related to breast cancer in advance as standards. We also used five keywords associated with breast cancer defined in the latest release of Systematized Nomenclature of Medicine-Clinical Terms (SNOMED CT) and analyzed their occurrence in the websites. Each search engine provided rich information related to breast cancer in the search results. All six standard websites were among the top 30 in search results of all four search engines. Google had the best search validity (in terms of whether a website could be opened), followed by Bing, Ask.com, and Yahoo!. The search results highly overlapped between the

  6. Information Uncertainty to Compare Qualitative Reasoning Security Risk Assessment Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chavez, Gregory M; Key, Brian P; Zerkle, David K

    2009-01-01

    The security risk associated with malevolent acts such as those of terrorism are often void of the historical data required for a traditional PRA. Most information available to conduct security risk assessments for these malevolent acts is obtained from subject matter experts as subjective judgements. Qualitative reasoning approaches such as approximate reasoning and evidential reasoning are useful for modeling the predicted risk from information provided by subject matter experts. Absent from these approaches is a consistent means to compare the security risk assessment results. Associated with each predicted risk reasoning result is a quantifiable amount of information uncertainty which canmore » be measured and used to compare the results. This paper explores using entropy measures to quantify the information uncertainty associated with conflict and non-specificity in the predicted reasoning results. The measured quantities of conflict and non-specificity can ultimately be used to compare qualitative reasoning results which are important in triage studies and ultimately resource allocation. Straight forward extensions of previous entropy measures are presented here to quantify the non-specificity and conflict associated with security risk assessment results obtained from qualitative reasoning models.« less

  7. Comparative evaluation of ibuprofen/beta-cyclodextrin complexes obtained by supercritical carbon dioxide and other conventional methods.

    PubMed

    Hussein, Khaled; Türk, Michael; Wahl, Martin A

    2007-03-01

    The preparation of drug/cyclodextrin complexes is a suitable method to improve the dissolution of poor soluble drugs. The efficacy of the Controlled Particle Deposition (CPD) as a new developed method to prepare these complexes in a single stage process using supercritical carbon dioxide is therefore compared with other conventional methods. Ibuprofen/beta-cyclodextrin complexes were prepared with different techniques and characterized using FTIR-ATR spectroscopy, powder X-ray diffractometry (PXRD), differential scanning calorimetry (DSC) and scanning electron microscopy (SEM). In addition, the influences of the processing technique on the drug content (HPLC) and the dissolution behavior were studied. Employing the CPD-process resulted in a drug content of 2.8+/-0.22 wt.% in the carrier. The material obtained by CPD showed an improved dissolution rate of ibuprofen at pH 5 compared with the pure drug and its physical mixture with beta-cyclodextrin. In addition CPD material displays the highest dissolution (93.5+/- 2.89% after 75 min) compared to material obtained by co-precipitation (61.3 +/-0.52%) or freeze-drying (90.6 +/-2.54%). This study presents the CPD-technique as a well suitable method to prepare a drug/beta-cyclodextrin complex with improved drug dissolution compared to the pure drug and materials obtained by other methods.

  8. Comparison of results obtained with various sensors used to measure fluctuating quantities in jets.

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P.; Massier, P. F.; Cuffel, R. F.

    1973-01-01

    An experimental investigation has been conducted to compare the results obtained with six different instruments that sense fluctuating quantities in free jets. These sensors are typical of those that have recently been used by various investigators who are engaged in experimental studies of jet noise. Intensity distributions and two-point correlations with space separation and time delay were obtained. The static pressure, density, and velocity fluctuations are well correlated over the entire cross section of the jet and the cross-correlations persist for several jet diameters along the flow direction. The eddies appear to be flattened in the flow direction by a ratio of 0.4.

  9. Globular-cluster stars - Results of theoretical evolution and pulsation studies compared with the observations.

    NASA Technical Reports Server (NTRS)

    Iben, I., Jr.

    1971-01-01

    Survey of recently published studies on globular clusters, and comparison of stellar evolution and pulsation theory with reported observations. The theory of stellar evolution is shown to be capable of describing, in principle, the behavior of a star through all quasi-static stages. Yet, as might be expected, estimates of bulk properties obtained by comparing observations with results of pulsation and stellar atmosphere theory differ somewhat from estimates of these same properties obtained by comparing observations with results of evolution theory. A description is given of how such estimates are obtained, and suggestions are offered as to where the weak points in each theory may lie.

  10. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results

    PubMed Central

    Tonyushkina, Ksenia; Nichols, James H.

    2009-01-01

    Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy

  11. Legionella in water samples: how can you interpret the results obtained by quantitative PCR?

    PubMed

    Ditommaso, Savina; Ricciardi, Elisa; Giacomuzzi, Monica; Arauco Rivera, Susan R; Zotti, Carla M

    2015-02-01

    Evaluation of the potential risk associated with Legionella has traditionally been determined from culture-based methods. Quantitative polymerase chain reaction (qPCR) is an alternative tool that offers rapid, sensitive and specific detection of Legionella in environmental water samples. In this study we compare the results obtained by conventional qPCR (iQ-Check™ Quanti Legionella spp.; Bio-Rad) and by culture method on artificial samples prepared in Page's saline by addiction of Legionella pneumophila serogroup 1 (ATCC 33152) and we analyse the selective quantification of viable Legionella cells by the qPCR-PMA method. The amount of Legionella DNA (GU) determined by qPCR was 28-fold higher than the load detected by culture (CFU). Applying the qPCR combined with PMA treatment we obtained a reduction of 98.5% of the qPCR signal from dead cells. We observed a dissimilarity in the ability of PMA to suppress the PCR signal in samples with different amounts of bacteria: the effective elimination of detection signals by PMA depended on the concentration of GU and increasing amounts of cells resulted in higher values of reduction. Using the results from this study we created an algorithm to facilitate the interpretation of viable cell level estimation with qPCR-PMA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Comparing Ultraviolet Spectra Against Calculations: First Results

    NASA Technical Reports Server (NTRS)

    Peterson, Ruth C.

    2003-01-01

    The five-year goal of this effort is to calculate high fidelity mid-UV spectra for individual stars and stellar systems for a wide range of ages, abundances, and abundance ratios. In this first year, the emphasis was placed on revising the list of atomic line parameters used to calculate mid-UV spectra. First, new identifications of atomic lines and measurements of their transition probabilities were obtained for lines of the first and second ionization stages of iron-peak elements. Second, observed mid-UV and optical spectra for standard stars were re-analyzed and compared to new calculations, to refine the determination of transition probabilities and to estimate the identity of lines still missing from the laboratory lists. As evidenced by the figures, a dramatic improvement has resulted in the reproduction of the spectra of standard stars by the calculations.

  13. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    PubMed

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  14. Comparison of Theoretical Stresses and Deflections of Multicell Wings with Experimental Results Obtained from Plastic Models

    NASA Technical Reports Server (NTRS)

    Zender, George W

    1956-01-01

    The experimental deflections and stresses of six plastic multicell-wing models of unswept, delta, and swept plan form are presented and compared with previously published theoretical results obtained by the electrical analog method. The comparisons indicate that the theory is reliable except for the evaluation of stresses in the vicinity of the leading edge of delta wings and the leading and trailing edges of swept wings. The stresses in these regions are questionable, apparently because of simplifications employed in idealizing the actual structure for theoretical purposes and because of local effects of concentrated loads.

  15. Water vapor over Europe obtained from remote sensors and compared with a hydrostatic NWP model

    NASA Astrophysics Data System (ADS)

    Johnsen, K.-P.; Kidder, S. Q.

    Due to its high-variability water vapor is a crucial parameter in short-term numerical weather prediction. Integrated water vapor (IWV) data obtained from a network of groundbased Global Positioning System (GPS) receivers mainly over Germany and passive microwave measurements of the Advanced Microwave Sounding Unit (AMSU-A) are compared with the high-resolution regional weather forecast model HRM of the Deutscher Wetterdienst (DWD). Time series of the IWV at 74 GPS stations obtained during the first complete year of the GFZ/GPS network between May 2000 and April 2001 are applied together with colocated forecasts of the HRM model. The low bias (0.08 kg/m 2) between the HRM model and the GPS data can mainly be explained by the bias between the ECMWF analysis data used to initilize the HRM model and the GPS data. The IWV standard deviation between the HRM model and the GPS data during that time is about 2.47 kg/ m2. GPS stations equipped with surface pressure sensors show about 0.29 kg/ m2 lower standard deviation compared with GPS stations with interpolated surface pressure from synoptic stations. The NOAA/NESDIS Total Precipitable Water algorithm is applied to obtain the IWV and to validate the model above the sea. While the mean IWV obtained from the HRM model is about 2.1 kg/ m2 larger than from the AMSU-A data, the standard deviations are 2.46 kg/ m2 (NOAA-15) and 2.29 kg/ m2 (NOAA-16) similar to the IWV standard deviation between HRM and GPS data.

  16. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    PubMed

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  17. Preliminary comparative assessment of PM10 hourly measurement results from new monitoring stations type using stochastic and exploratory methodology and models

    NASA Astrophysics Data System (ADS)

    Czechowski, Piotr Oskar; Owczarek, Tomasz; Badyda, Artur; Majewski, Grzegorz; Rogulski, Mariusz; Ogrodnik, Paweł

    2018-01-01

    The paper presents selected preliminary stage key issues proposed extended equivalence measurement results assessment for new portable devices - the comparability PM10 concentration results hourly series with reference station measurement results with statistical methods. In article presented new portable meters technical aspects. The emphasis was placed on the comparability the results using the stochastic and exploratory methods methodology concept. The concept is based on notice that results series simple comparability in the time domain is insufficient. The comparison of regularity should be done in three complementary fields of statistical modeling: time, frequency and space. The proposal is based on model's results of five annual series measurement results new mobile devices and WIOS (Provincial Environmental Protection Inspectorate) reference station located in Nowy Sacz city. The obtained results indicate both the comparison methodology completeness and the high correspondence obtained new measurements results devices with reference.

  18. Different Techniques For Producing Precision Holes (>20 mm) In Hardened Steel—Comparative Results

    NASA Astrophysics Data System (ADS)

    Coelho, R. T.; Tanikawa, S. T.

    2009-11-01

    High speed machining (HSM), or high performance machining, has been one of the most recent technological advances. When applied to milling operations, using adequate machines, CAM programs and tooling, it allows cutting hardened steels, which was not feasible just a couple of years ago. The use of very stiff and precision machines has created the possibilities of machining holes in hardened steels, such as AISI H13 with 48-50 HRC, using helical interpolations, for example. Such process is particularly useful for holes with diameter bigger than normal solid carbide drills commercially available, around 20 mm, or higher. Such holes may need narrow tolerances, fine surface finishing, which can be obtained just by end milling operations. The present work compares some of the strategies used to obtain such holes by end milling, and also some techniques employed to finish them, by milling, boring and also by fine grinding at the same machine. Results indicate that it is possible to obtain holes with less than 0.36 m in circularity, 7.41 m in cylindricity and 0.12 m in surface roughness Ra. Additionally, there is less possibilities of obtaining heat affected layers when using such technique.

  19. Results obtained with a low cost software-based audiometer for hearing screening.

    PubMed

    Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis

    2013-07-01

     The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening.  To evaluate the TS audiometer for conducting audiometric screening.  A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated.  For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively.  The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.

  20. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): A Transversal, descriptive, and comparative study

    PubMed Central

    2010-01-01

    Background To assess the reliability of the measurements obtained with the PalmScan™, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Methods Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan™ A2000 and Eye Cubed™) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. Results 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed™ of AL and ACD were shorter than the measurements taken by the PalmScan™. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan™ measurements were shorter, but not statistically significantly (p < 0.2). Conclusions The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon. PMID:20334670

  1. The Comparing Options for Management: Patient-centered Results for Uterine Fibroids (COMPARE-UF) Registry: Rationale and Design.

    PubMed

    Stewart, Elizabeth A; Lytle, Barbara L; Thomas, Laine; Wegienka, Ganesa R; Jacoby, Vanessa; Diamond, Michael P; Nicholson, Wanda K; Anchan, Raymond M; Venable, Sateria; Wallace, Kedra; Marsh, Erica E; Maxwell, George L; Borah, Bijan J; Catherino, William H; Myers, Evan R

    2018-05-08

    To design and establish a uterine fibroid (UF) registry based in the United States (US) to provide comparative effectiveness data regarding UF treatment. We report here the design and initial recruitment for the Comparing Options for Management: Patient-centered Results for Uterine Fibroids (COMPARE-UF) registry (Clinicaltrials.gov, NCT02260752), funded by the Agency for Healthcare Research and Quality (AHRQ) in collaboration with the-Patient-Centered Outcomes Research Institute (PCORI). COMPARE-UF is designed to help answer critical questions about treatment options for women with symptomatic UF. Women undergoing a procedure for UF (hysterectomy, myomectomy [abdominal, hysteroscopic, vaginal and laparoscopic/robotic], endometrial ablation, radiofrequency fibroid ablation, uterine artery embolization, magnetic resonance guided focused ultrasound or progestin-releasing intrauterine device insertion) at one of the COMPARE-UF sites are invited to participate in a prospective registry with three years follow-up for post-procedural outcomes. Enrolled participants provide annual follow-up through an online portal or through traditional phone contact. A central data abstraction center provides information obtained from imaging, operative or procedural notes and pathology reports. Women with uterine fibroids and other stakeholders are a key part of the COMPARE-UF registry and participate at all points from study design to dissemination of results. We built a network of nine clinical sites across the US with expertise in the care of women with UF to capture geographic, racial, ethnic and procedural diversity. Of the initial 2031 women enrolled in COMPARE-UF, 42% are self-identified as Black or African-American and 40% are age 40 years or younger with 16% of participants under age 35. Women undergoing myomectomy comprise the largest treatment group at 46% of all procedures with laparoscopic or robotic myomectomy comprising the largest subset of myomectomies at 19% of all

  2. Comparative Analysis of 3D Bladder Tumor Spheroids Obtained by Forced Floating and Hanging Drop Methods for Drug Screening.

    PubMed

    Amaral, Robson L F; Miranda, Mariza; Marcato, Priscyla D; Swiech, Kamilla

    2017-01-01

    Introduction: Cell-based assays using three-dimensional (3D) cell cultures may reflect the antitumor activity of compounds more accurately, since these models reproduce the tumor microenvironment better. Methods: Here, we report a comparative analysis of cell behavior in the two most widely employed methods for 3D spheroid culture, forced floating (Ultra-low Attachment, ULA, plates), and hanging drop (HD) methods, using the RT4 human bladder cancer cell line as a model. The morphology parameters and growth/metabolism of the spheroids generated were first characterized, using four different cell-seeding concentrations (0.5, 1.25, 2.5, and 3.75 × 10 4 cells/mL), and then, subjected to drug resistance evaluation. Results: Both methods generated spheroids with a smooth surface and round shape in a spheroidization time of about 48 h, regardless of the cell-seeding concentration used. Reduced cell growth and metabolism was observed in 3D cultures compared to two-dimensional (2D) cultures. The optimal range of spheroid diameter (300-500 μm) was obtained using cultures initiated with 0.5 and 1.25 × 10 4 cells/mL for the ULA method and 2.5 and 3.75 × 10 4 cells/mL for the HD method. RT4 cells cultured under 3D conditions also exhibited a higher resistance to doxorubicin (IC 50 of 1.00 and 0.83 μg/mL for the ULA and HD methods, respectively) compared to 2D cultures (IC 50 ranging from 0.39 to 0.43). Conclusions: Comparing the results, we concluded that the forced floating method using ULA plates was considered more suitable and straightforward to generate RT4 spheroids for drug screening/cytotoxicity assays. The results presented here also contribute to the improvement in the standardization of the 3D cultures required for widespread application.

  3. Comparative Analysis of 3D Bladder Tumor Spheroids Obtained by Forced Floating and Hanging Drop Methods for Drug Screening

    PubMed Central

    Amaral, Robson L. F.; Miranda, Mariza; Marcato, Priscyla D.; Swiech, Kamilla

    2017-01-01

    Introduction: Cell-based assays using three-dimensional (3D) cell cultures may reflect the antitumor activity of compounds more accurately, since these models reproduce the tumor microenvironment better. Methods: Here, we report a comparative analysis of cell behavior in the two most widely employed methods for 3D spheroid culture, forced floating (Ultra-low Attachment, ULA, plates), and hanging drop (HD) methods, using the RT4 human bladder cancer cell line as a model. The morphology parameters and growth/metabolism of the spheroids generated were first characterized, using four different cell-seeding concentrations (0.5, 1.25, 2.5, and 3.75 × 104 cells/mL), and then, subjected to drug resistance evaluation. Results: Both methods generated spheroids with a smooth surface and round shape in a spheroidization time of about 48 h, regardless of the cell-seeding concentration used. Reduced cell growth and metabolism was observed in 3D cultures compared to two-dimensional (2D) cultures. The optimal range of spheroid diameter (300–500 μm) was obtained using cultures initiated with 0.5 and 1.25 × 104 cells/mL for the ULA method and 2.5 and 3.75 × 104 cells/mL for the HD method. RT4 cells cultured under 3D conditions also exhibited a higher resistance to doxorubicin (IC50 of 1.00 and 0.83 μg/mL for the ULA and HD methods, respectively) compared to 2D cultures (IC50 ranging from 0.39 to 0.43). Conclusions: Comparing the results, we concluded that the forced floating method using ULA plates was considered more suitable and straightforward to generate RT4 spheroids for drug screening/cytotoxicity assays. The results presented here also contribute to the improvement in the standardization of the 3D cultures required for widespread application. PMID:28878686

  4. Results of the 2013 UT modeling benchmark obtained with models implemented in CIVA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toullelan, Gwénaël; Raillon, Raphaële; Chatillon, Sylvain

    The 2013 Ultrasonic Testing (UT) modeling benchmark concerns direct echoes from side drilled holes (SDH), flat bottom holes (FBH) and corner echoes from backwall breaking artificial notches inspected with a matrix phased array probe. This communication presents the results obtained with the models implemented in the CIVA software: the pencilmodel is used to compute the field radiated by the probe, the Kirchhoff approximation is applied to predict the response of FBH and notches and the SOV (Separation Of Variables) model is used for the SDH responses. The comparison between simulated and experimental results are presented and discussed.

  5. The Comparability of Focus Group and Survey Results: Three Case Studies.

    ERIC Educational Resources Information Center

    Ward, Victoria M.; And Others

    1991-01-01

    Focus group findings were compared with survey findings for three studies in which both methods were used. Studies conducted on voluntary sterilization in Guatemala, Honduras, and Zaire with over 2,000 subjects confirm that focus groups yield information similar to that obtained from surveys and are useful in program planning. (SLD)

  6. Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children.

    PubMed

    Kocabeyoglu, Sibel; Uzun, Salih; Mocan, Mehmet Cem; Bozkurt, Banu; Irkec, Murat; Orhan, Mehmet

    2013-10-01

    The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. This prospective study included 55 healthy children without ocular or systemic disorders who underwent both SAP and frequency doubling technology (FDT) perimetry visual field testing. Visual field test reliability indices, test duration, global indices (mean deviation [MD], and pattern standard deviation [PSD]) were compared between the 2 tests using the Wilcoxon signed-rank test and paired t-test. The performance of the Humphrey field analyzer (HFA) 24-2 SITA-standard and frequency-doubling technology Matrix 24-2 tests between genders were compared with Mann-Whitney U-test. Fifty-five healthy children with a mean age of 12.2 ± 1.9 years (range from 8 years to 16 years) were included in this prospective study. The test durations of SAP and FDT were similar (5.2 ± 0.5 and 5.1 ± 0.2 min, respectively, P = 0.651). MD and the PSD values obtained via FDT Matrix were significantly higher than those obtained via SAP (P < 0.001), and fixation losses and false negative errors were significantly less with SAP (P < 0.05). A weak positive correlation between the two tests in terms of MD (r = 0.352, P = 0.008) and PSD (r = 0.329, P = 0.014) was observed. Children were able to complete both the visual test algorithms successfully within 6 min. However, SAP testing appears to be associated with less depression of the visual field indices of healthy children. FDT Matrix and SAP should not be used interchangeably in the follow-up of children.

  7. Using Riemannian geometry to obtain new results on Dikin and Karmarkar methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliveira, P.; Joao, X.; Piaui, T.

    1994-12-31

    We are motivated by a 1990 Karmarkar paper on Riemannian geometry and Interior Point Methods. In this talk we show 3 results. (1) Karmarkar direction can be derived from the Dikin one. This is obtained by constructing a certain Z(x) representation of the null space of the unitary simplex (e, x) = 1; then the projective direction is the image under Z(x) of the affine-scaling one, when it is restricted to that simplex. (2) Second order information on Dikin and Karmarkar methods. We establish computable Hessians for each of the metrics corresponding to both directions, thus permitting the generation ofmore » {open_quotes}second order{close_quotes} methods. (3) Dikin and Karmarkar geodesic descent methods. For those directions, we make computable the theoretical Luenberger geodesic descent method, since we are able to explicit very accurate expressions of the corresponding geodesics. Convergence results are given.« less

  8. Comparative and Joint Analysis of Two Metagenomic Datasets from a Biogas Fermenter Obtained by 454-Pyrosequencing

    PubMed Central

    Jaenicke, Sebastian; Ander, Christina; Bekel, Thomas; Bisdorf, Regina; Dröge, Marcus; Gartemann, Karl-Heinz; Jünemann, Sebastian; Kaiser, Olaf; Krause, Lutz; Tille, Felix; Zakrzewski, Martha; Pühler, Alfred

    2011-01-01

    Biogas production from renewable resources is attracting increased attention as an alternative energy source due to the limited availability of traditional fossil fuels. Many countries are promoting the use of alternative energy sources for sustainable energy production. In this study, a metagenome from a production-scale biogas fermenter was analysed employing Roche's GS FLX Titanium technology and compared to a previous dataset obtained from the same community DNA sample that was sequenced on the GS FLX platform. Taxonomic profiling based on 16S rRNA-specific sequences and an Environmental Gene Tag (EGT) analysis employing CARMA demonstrated that both approaches benefit from the longer read lengths obtained on the Titanium platform. Results confirmed Clostridia as the most prevalent taxonomic class, whereas species of the order Methanomicrobiales are dominant among methanogenic Archaea. However, the analyses also identified additional taxa that were missed by the previous study, including members of the genera Streptococcus, Acetivibrio, Garciella, Tissierella, and Gelria, which might also play a role in the fermentation process leading to the formation of methane. Taking advantage of the CARMA feature to correlate taxonomic information of sequences with their assigned functions, it appeared that Firmicutes, followed by Bacteroidetes and Proteobacteria, dominate within the functional context of polysaccharide degradation whereas Methanomicrobiales represent the most abundant taxonomic group responsible for methane production. Clostridia is the most important class involved in the reductive CoA pathway (Wood-Ljungdahl pathway) that is characteristic for acetogenesis. Based on binning of 16S rRNA-specific sequences allocated to the dominant genus Methanoculleus, it could be shown that this genus is represented by several different species. Phylogenetic analysis of these sequences placed them in close proximity to the hydrogenotrophic methanogen Methanoculleus

  9. Near-Infrared Scintillation of Liquid Argon: Recent Results Obtained with the NIR Facility at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Escobar, C. O.; Rubinov, P.; Tilly, E.

    After a short review of previous attempts to observe and measure the near-infrared scintillation in liquid argon, we present new results obtained with NIR, a dedicated cryostat at the Fermilab Proton Assembly Building (PAB). The new results give confidence that the near-infrared light can be used as the much needed light signal in large liquid argon time projection chambers.11 pages,

  10. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    PubMed

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  11. Results of Investigative Tests of Gas Turbine Engine Compressor Blades Obtained by Electrochemical Machining

    NASA Astrophysics Data System (ADS)

    Kozhina, T. D.; Kurochkin, A. V.

    2016-04-01

    The paper highlights results of the investigative tests of GTE compressor Ti-alloy blades obtained by the method of electrochemical machining with oscillating tool-electrodes, carried out in order to define the optimal parameters of the ECM process providing attainment of specified blade quality parameters given in the design documentation, while providing maximal performance. The new technological methods suggested based on the results of the tests; in particular application of vibrating tool-electrodes and employment of locating elements made of high-strength materials, significantly extend the capabilities of this method.

  12. An assessment of consistence of exhaust gas emission test results obtained under controlled NEDC conditions

    NASA Astrophysics Data System (ADS)

    Balawender, K.; Jaworski, A.; Kuszewski, H.; Lejda, K.; Ustrzycki, A.

    2016-09-01

    Measurements concerning emissions of pollutants contained in automobile combustion engine exhaust gases is of primary importance in view of their harmful impact on the natural environment. This paper presents results of tests aimed at determining exhaust gas pollutant emissions from a passenger car engine obtained under repeatable conditions on a chassis dynamometer. The test set-up was installed in a controlled climate chamber allowing to maintain the temperature conditions within the range from -20°C to +30°C. The analysis covered emissions of such components as CO, CO2, NOx, CH4, THC, and NMHC. The purpose of the study was to assess repeatability of results obtained in a number of tests performed as per NEDC test plan. The study is an introductory stage of a wider research project concerning the effect of climate conditions and fuel type on emission of pollutants contained in exhaust gases generated by automotive vehicles.

  13. Comparing synthetic imagery with real imagery for visible signature analysis: human observer results

    NASA Astrophysics Data System (ADS)

    Culpepper, Joanne B.; Richards, Noel; Madden, Christopher S.; Winter, Neal; Wheaton, Vivienne C.

    2017-10-01

    Synthetic imagery could potentially enhance visible signature analysis by providing a wider range of target images in differing environmental conditions than would be feasible to collect in field trials. Achieving this requires a method for generating synthetic imagery that is both verified to be realistic and produces the same visible signature analysis results as real images. Is target detectability as measured by image metrics the same for real images and synthetic images of the same scene? Is target detectability as measured by human observer trials the same for real images and synthetic images of the same scene, and how realistic do the synthetic images need to be? In this paper we present the results of a small scale exploratory study on the second question: a photosimulation experiment conducted using digital photographs and synthetic images generated of the same scene. Two sets of synthetic images were created: a high fidelity set created using an image generation tool, E-on Vue, and a low fidelity set created using a gaming engine, Unity 3D. The target detection results obtained using digital photographs were compared with those obtained using the two sets of synthetic images. There was a moderate correlation between the high fidelity synthetic image set and the real images in both the probability of correct detection (Pd: PCC = 0.58, SCC = 0.57) and mean search time (MST: PCC = 0.63, SCC = 0.61). There was no correlation between the low fidelity synthetic image set and the real images for the Pd, but a moderate correlation for MST (PCC = 0.67, SCC = 0.55).

  14. easyGWAS: A Cloud-Based Platform for Comparing the Results of Genome-Wide Association Studies.

    PubMed

    Grimm, Dominik G; Roqueiro, Damian; Salomé, Patrice A; Kleeberger, Stefan; Greshake, Bastian; Zhu, Wangsheng; Liu, Chang; Lippert, Christoph; Stegle, Oliver; Schölkopf, Bernhard; Weigel, Detlef; Borgwardt, Karsten M

    2017-01-01

    The ever-growing availability of high-quality genotypes for a multitude of species has enabled researchers to explore the underlying genetic architecture of complex phenotypes at an unprecedented level of detail using genome-wide association studies (GWAS). The systematic comparison of results obtained from GWAS of different traits opens up new possibilities, including the analysis of pleiotropic effects. Other advantages that result from the integration of multiple GWAS are the ability to replicate GWAS signals and to increase statistical power to detect such signals through meta-analyses. In order to facilitate the simple comparison of GWAS results, we present easyGWAS, a powerful, species-independent online resource for computing, storing, sharing, annotating, and comparing GWAS. The easyGWAS tool supports multiple species, the uploading of private genotype data and summary statistics of existing GWAS, as well as advanced methods for comparing GWAS results across different experiments and data sets in an interactive and user-friendly interface. easyGWAS is also a public data repository for GWAS data and summary statistics and already includes published data and results from several major GWAS. We demonstrate the potential of easyGWAS with a case study of the model organism Arabidopsis thaliana , using flowering and growth-related traits. © 2016 American Society of Plant Biologists. All rights reserved.

  15. Airglow during ionospheric modifications by the sura facility radiation. experimental results obtained in 2010

    NASA Astrophysics Data System (ADS)

    Grach, S. M.; Klimenko, V. V.; Shindin, A. V.; Nasyrov, I. A.; Sergeev, E. N.; A. Yashnov, V.; A. Pogorelko, N.

    2012-06-01

    We present the results of studying the structure and dynamics of the HF-heated volume above the Sura facility obtained in 2010 by measurements of ionospheric airglow in the red (λ = 630 nm) and green (λ = 557.7 nm) lines of atomic oxygen. Vertical sounding of the ionosphere (followed by modeling of the pump-wave propagation) and measurements of stimulated electromagnetic emission were used for additional diagnostics of ionospheric parameters and the processes occurring in the heated volume.

  16. Health Outcomes of Obtaining Housing Among Older Homeless Adults

    PubMed Central

    Miao, Yinghui; Mitchell, Susan L.; Bharel, Monica; Patel, Mitkumar; Ard, Kevin L.; Grande, Laura J.; Blazey-Martin, Deborah; Floru, Daniella; Steinman, Michael A.

    2015-01-01

    Objectives. We determined the impact of obtaining housing on geriatric conditions and acute care utilization among older homeless adults. Methods. We conducted a 12-month prospective cohort study of 250 older homeless adults recruited from shelters in Boston, Massachusetts, between January and June 2010. We determined housing status at follow-up, determined number of emergency department visits and hospitalizations over 12 months, and examined 4 measures of geriatric conditions at baseline and 12 months. Using multivariable regression models, we evaluated the association between obtaining housing and our outcomes of interest. Results. At 12-month follow-up, 41% of participants had obtained housing. Compared with participants who remained homeless, those with housing had fewer depressive symptoms. Other measures of health status did not differ by housing status. Participants who obtained housing had a lower rate of acute care use, with an adjusted annualized rate of acute care visits of 2.5 per year among participants who obtained housing and 5.3 per year among participants who remained homeless. Conclusions. Older homeless adults who obtained housing experienced improved depressive symptoms and reduced acute care utilization compared with those who remained homeless. PMID:25973822

  17. Comparative study of the results from conventional cervico-vaginal oncotic cytology and liquid-based cytology.

    PubMed

    Stabile, Sueli Aparecida Batista; Evangelista, Dilson Henrique Ramos; Talamonte, Valdely Helena; Lippi, Umberto Gazi; Lopes, Reginaldo Guedes Coelho

    2012-01-01

    To compare two oncotic cervical cytology techniques, the conventional and the liquid-based cytology, in low risk patients for uterine cervical cancer. Comparative prospective study with 100 patients who came to their annual gynecological exam, and were submitted simultaneously to both techniques. We used the McNemar test, with a significance level of p < 0.05 to compare the results obtained related to adequacy of the smear quality, descriptive diagnosis prevalence, guided biopsy confirmation and histology. Adequacy of the smear was similar for both methods. The quality with squamocolumnar junction in 93% of conventional cytology and in 84% of the liquid-based cytology had statistical significance. As for the diagnosis of atypical cells they were detected in 3% of conventional cytology and in 10% of liquid-based cytology (p = 0.06). Atypical squamous cells of undetermined significance were the most prevalent abnormality. The liquid-based cytology performance was better when compared with colposcopy (guided biopsy), presenting sensitivity of 66.7% and specificity of 100%. There was no cytological and histological concordance for the conventional cytology. Liquid-based cytology had a better performance to diagnose atypical cells and the cytohistological concordance was higher than in the conventional cytology.

  18. Spinning Characteristics of the XN2Y-1 Airplane Obtained from the Spinning Balance and Compared with Results from the Spinning Tunnel and from Flight Tests

    NASA Technical Reports Server (NTRS)

    Bamber, M J; House, R O

    1937-01-01

    Report presents the results of tests of a 1/10-scale model of the XN2Y-1 airplane tested in the NACA 5-foot vertical wind tunnel in which the six components of forces and moments were measured. The model was tested in 17 attitudes in which the full-scale airplane had been observed to spin, in order to determine the effects of scale, tunnel, and interference. In addition, a series of tests was made to cover the range of angles of attack, angles of sideslip, rates of rotation, and control setting likely to be encountered by a spinning airplane. The data were used to estimate the probable attitudes in steady spins of an airplane in flight and of a model in the free-spinning tunnel. The estimated attitudes of steady spin were compared with attitudes measured in flight and in the spinning tunnel. The results indicate that corrections for certain scale and tunnel effects are necessary to estimate full-scale spinning attitudes from model results.

  19. Comparative proteomic analysis using samples obtained with laser microdissection and saturation dye labelling.

    PubMed

    Wilson, Kate E; Marouga, Rita; Prime, John E; Pashby, D Paul; Orange, Paul R; Crosier, Steven; Keith, Alexander B; Lathe, Richard; Mullins, John; Estibeiro, Peter; Bergling, Helene; Hawkins, Edward; Morris, Christopher M

    2005-10-01

    Comparative proteomic methods are rapidly being applied to many different biological systems including complex tissues. One pitfall of these methods is that in some cases, such as oncology and neuroscience, tissue complexity requires isolation of specific cell types and sample is limited. Laser microdissection (LMD) is commonly used for obtaining such samples for proteomic studies. We have combined LMD with sensitive thiol-reactive saturation dye labelling of protein samples and 2-D DIGE to identify protein changes in a test system, the isolated CA1 pyramidal neurone layer of a transgenic (Tg) rat carrying a human amyloid precursor protein transgene. Saturation dye labelling proved to be extremely sensitive with a spot map of over 5,000 proteins being readily produced from 5 mug total protein, with over 100 proteins being significantly altered at p < 0.0005. Of the proteins identified, all showed coherent changes associated with transgene expression. It was, however, difficult to identify significantly different proteins using PMF and MALDI-TOF on gels containing less than 500 mug total protein. The use of saturation dye labelling of limiting samples will therefore require the use of highly sensitive MS techniques to identify the significantly altered proteins isolated using methods such as LMD.

  20. Optimization of the parameters for obtaining zirconia-alumina coatings, made by flame spraying from results of numerical simulation

    NASA Astrophysics Data System (ADS)

    Ferrer, M.; Vargas, F.; Peña, G.

    2017-12-01

    The K-Sommerfeld values (K) and the melting percentage (% F) obtained by numerical simulation using the Jets et Poudres software were used to find the projection parameters of zirconia-alumina coatings by thermal spraying flame, in order to obtain coatings with good morphological and structural properties to be used as thermal insulation. The experimental results show the relationship between the Sommerfeld parameter and the porosity of the zirconia-alumina coatings. It is found that the lowest porosity is obtained when the K-Sommerfeld value is close to 45 with an oxidant flame, on the contrary, when superoxidant flames are used K values are close 52, which improve wear resistance.

  1. New high-definition thickness data obtained at tropical glaciers: preliminary results from Antisana volcano (Ecuador) using GPR prospection

    NASA Astrophysics Data System (ADS)

    Zapata, Camilo; Andrade, Daniel; Córdova, Jorge; Maisincho, Luis; Carvajal, Juan; Calispa, Marlon; Villacís, Marcos

    2014-05-01

    The study of tropical glaciers has been a significant contribution to the understanding of glacier dynamics and climate change. Much of the data and results have been obtained by analyzing plan-view images obtained by air- and space-borne sensors, as well as depth data obtained by diverse methodologies at selected points on the glacier surface. However, the measurement of glacier thicknesses has remained an elusive task in tropical glaciers, often located in rough terrains where the application of geophysical surveys (i.e. seismic surveys) requires logistics sometimes hardly justified by the amount of obtained data. In the case of Ecuador, however, where most glaciers have developed on active volcanoes and represent sources/reservoirs of fresh water, the precise knowledge of such information is fundamental for scientific research but also in order to better assess key aspects for the society. The relatively recent but fast development of the GPR technology has helped to obtain new highdefinition thickness data at Antisana volcano that will be used to: 1) better understand the dynamics and fate of tropical glaciers; 2) better estimate the amount of fresh water stored in the glaciers; 3) better assess the hazards associated with the sudden widespread melting of glaciers during volcanic eruptions. The measurements have been obtained at glaciers 12 and 15 of Antisana volcano, with the help of a commercial GPR equipped with a 25 MHz antenna. A total of 30 transects have been obtained, covering a distance of more than 3 km, from the glacier ablation zone, located at ~ 4600 masl, up to the level of 5200 masl. The preliminary results show a positive correlation between altitude and glacier thickness, with maximum and minimum calculated values reaching up to 80 m, and down to 15 m, respectively. The experience gained at Antisana volcano will be used to prepare a more widespread GPR survey in the glaciers of Cotopaxi volcano, whose implications in terms of volcanic hazards

  2. Comparison of the results of refractometric measurements in the process of diffusion, obtained by means of the backgroundoriented schlieren method and the holographic interferometry method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kraiskii, A V; Mironova, T V

    2015-08-31

    The results of the study of interdiffusion of two liquids, obtained using the holographic recording scheme with a nonstationary reference wave with the frequency linearly varying in space and time are compared with the results of correlation processing of digital photographs, made with a random background screen. The spatio-temporal behaviour of the signal in four basic representations ('space – temporal frequency', 'space – time', 'spatial frequency – temporal frequency' and 'spatial frequency – time') is found in the holographic experiment and calculated (in the appropriate coordinates) based on the background-oriented schlieren method. Practical coincidence of the results of the correlationmore » analysis and the holographic double-exposure interferometry is demonstrated. (interferometry)« less

  3. A Conversion Formula for Comparing Pulse Oximeter Desaturation Rates Obtained with Different Averaging Times

    PubMed Central

    Vagedes, Jan; Bialkowski, Anja; Wiechers, Cornelia; Poets, Christian F.; Dietz, Klaus

    2014-01-01

    Objective The number of desaturations determined in recordings of pulse oximeter saturation (SpO2) primarily depends on the time over which values are averaged. As the averaging time in pulse oximeters is not standardized, it varies considerably between centers. To make SpO2 data comparable, it is thus desirable to have a formula that allows conversion between desaturation rates obtained using different averaging times for various desaturation levels and minimal durations. Methods Oxygen saturation was measured for 170 hours in 12 preterm infants with a mean number of 65 desaturations <90% per hour of arbitrary duration by using a pulse oximeter in a 2–4 s averaging mode. Using 7 different averaging times between 3 and 16 seconds, the raw red-to-infrared data were reprocessed to determine the number of desaturations (D). The whole procedure was carried out for 7 different minimal desaturation durations (≥1, ≥5, ≥10, ≥15, ≥20, ≥25, ≥30 s) below SpO2 threshold values of 80%, 85% or 90% to finally reach a conversion formula. The formula was validated by splitting the infants into two groups of six children each and using one group each as a training set and the other one as a test set. Results Based on the linear relationship found between the logarithm of the desaturation rate and the logarithm of the averaging time, the conversion formula is: D2 = D1 (T2/T1)c, where D2 is the desaturation rate for the desired averaging time T2, and D1 is the desaturation rate for the original averaging time T1, with the exponent c depending on the desaturation threshold and the minimal desaturation duration. The median error when applying this formula was 2.6%. Conclusion This formula enables the conversion of desaturation rates between different averaging times for various desaturation thresholds and minimal desaturation durations. PMID:24489887

  4. GHM method for obtaining rationalsolutions of nonlinear differential equations.

    PubMed

    Vazquez-Leal, Hector; Sarmiento-Reyes, Arturo

    2015-01-01

    In this paper, we propose the application of the general homotopy method (GHM) to obtain rational solutions of nonlinear differential equations. It delivers a high precision representation of the nonlinear differential equation using a few linear algebraic terms. In order to assess the benefits of this proposal, three nonlinear problems are solved and compared against other semi-analytic methods or numerical methods. The obtained results show that GHM is a powerful tool, capable to generate highly accurate rational solutions. AMS subject classification 34L30.

  5. Geodetic results from ISAGEX data. [for obtaining center of mass coordinates for geodetic camera sites

    NASA Technical Reports Server (NTRS)

    Marsh, J. G.; Douglas, B. C.; Walls, D. M.

    1974-01-01

    Laser and camera data taken during the International Satellite Geodesy Experiment (ISAGEX) were used in dynamical solutions to obtain center-of-mass coordinates for the Astro-Soviet camera sites at Helwan, Egypt, and Oulan Bator, Mongolia, as well as the East European camera sites at Potsdam, German Democratic Republic, and Ondrejov, Czechoslovakia. The results are accurate to about 20m in each coordinate. The orbit of PEOLE (i=15) was also determined from ISAGEX data. Mean Kepler elements suitable for geodynamic investigations are presented.

  6. Comparing the rankings obtained from two biodiversity indices: the Fair Proportion Index and the Shapley Value.

    PubMed

    Wicke, Kristina; Fischer, Mareike

    2017-10-07

    The Shapley Value and the Fair Proportion Index of phylogenetic trees have been frequently discussed as prioritization tools in conservation biology. Both indices rank species according to their contribution to total phylogenetic diversity, allowing for a simple conservation criterion. While both indices have their specific advantages and drawbacks, it has recently been shown that both values are closely related. However, as different authors use different definitions of the Shapley Value, the specific degree of relatedness depends on the specific version of the Shapley Value - it ranges from a high correlation index to equality of the indices. In this note, we first give an overview of the different indices. Then we turn our attention to the mere ranking order provided by either of the indices. We compare the rankings obtained from different versions of the Shapley Value for a phylogenetic tree of European amphibians and illustrate their differences. We then undertake further analyses on simulated data and show that even though the chance of two rankings being exactly identical (when obtained from different versions of the Shapley Value) decreases with an increasing number of taxa, the distance between the two rankings converges to zero, i.e., the rankings are becoming more and more alike. Moreover, we introduce our freely available software package FairShapley, which was implemented in Perl and with which all calculations have been performed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Main results and experience obtained on Mir space station and experiment program for Russian segment of ISS.

    PubMed

    Utkin, V F; Lukjashchenko, V I; Borisov, V V; Suvorov, V V; Tsymbalyuk, M M

    2003-07-01

    This article presents main scientific and practical results obtained in course of scientific and applied research and experiments on Mir space station. Based on Mir experience, processes of research program formation for the Russian Segment of the ISS are briefly described. The major trends of activities planned in the frames of these programs as well as preliminary results of increment research programs implementation in the ISS' first missions are also presented. c2003 Elsevier Science Ltd. All rights reserved.

  8. 25 CFR 162.539 - Must I obtain a WEEL before obtaining a WSR lease?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... AND PERMITS Wind and Solar Resource Leases Wsr Leases § 162.539 Must I obtain a WEEL before obtaining... direct result of energy resource information gathered from a WEEL activity, obtaining a WEEL is not a...

  9. 25 CFR 162.539 - Must I obtain a WEEL before obtaining a WSR lease?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... AND PERMITS Wind and Solar Resource Leases Wsr Leases § 162.539 Must I obtain a WEEL before obtaining... direct result of energy resource information gathered from a WEEL activity, obtaining a WEEL is not a...

  10. Comparing association of preoperative transrectal ultrasound prostate weight with prostate weight obtained after radical prostatectomy after adjustment for other prognostic factors in a subset of the Northwestern University Prostate SPORE database

    NASA Astrophysics Data System (ADS)

    Helenowski, Irene; Jovanovic, Borko; Gurley, Michael; Leikin, Robin; Catalona, William; Roston, Arden; Kuzel, Timothy

    Transrectal ultrasound (TRUS) is a non-invasive approach to measure prostate size as a surrogate (density =1.0) for prostate weight with implications in prostate cancer prognosis. But the question is how reliable is this preoperative measurement compared to other measures of prostate weight. This work presents the correlations between preoperative TRUS prostate weight and prostate weight obtained after radical prostatectomy in 434 patients with mean TRUS weight 36g (range: 10g-120g) and the mean prostate weight obtained after radical prostatectomy 51g (range: 16g-180g) from the Northwestern University Prostate SPORE database. 311 patients with weight obtained by digital rectal exam (DRE) were also compared to the TRUS prostate weights with mean and range of DRE weights 33g (10g - 78g). Correlations were adjusted by age, BMI, an indicator variable for a pathological stage of III or greater, and for Gleason score greater than 7. Correlations were also computed for separately for European American and Other Race populations. Differences in means were evaluated via the paired t-test. Results indicate TRUS measures obtained via ultrasound as promising but improvement in the technology still appears needed.

  11. Comparative energy content and amino acid digestibility of barley obtained from diverse sources fed to growing pigs.

    PubMed

    Wang, Hong Liang; Shi, Meng; Xu, Xiao; Ma, Xiao Kang; Liu, Ling; Piao, Xiang Shu

    2017-07-01

    Two experiments were conducted to determine the content of digestible energy (DE) and metabolizable energy (ME) as well as the apparent ileal digestibility (AID) and standardized ileal digestibility (SID) of crude protein (CP) and amino acids (AA) in barley grains obtained from Australia, France or Canada. In Exp. 1, 18 growing barrows (Duroc×Landrace×Yorkshire; 31.5±3.2 kg) were individually placed in stainless-steel metabolism crates (1.4×0.7×0.6 m) and randomly allotted to 1 of 3 test diets. In Exp. 2, eight crossbred pigs (30.9±1.8 kg) were allotted to a replicate 3×4 Youden Square designed experiment with three periods and four diets. Two pigs received each diet during each test period. The diets included one nitrogen-free diet and three test diets. The relative amounts of gross energy (GE), CP, and all AA in the Canadian barley were higher than those in Australian and French barley while higher concentrations of neutral detergent fiber, acid detergent fiber, total dietary fiber, insoluble dietary fiber and β-glucan as well as lower concentrations of GE and ether extract were observed in the French barley compared with the other two barley sources. The DE and ME as well as the SID of histidine, isoleucine, leucine and phenylalanine in Canadian barley were higher (p<0.05) than those in French barley but did not differ from Australian barley. Differences in the chemical composition, energy content and the SID and AID of AA were observed among barley sources obtained from three countries. The feeding value of barley from Canada and Australia was superior to barley obtained from France which is important information in developing feeding systems for growing pigs where imported grains are used.

  12. Comparative study of aerogels obtained from differently prepared nanocellulose fibers.

    PubMed

    Chen, Wenshuai; Li, Qing; Wang, Youcheng; Yi, Xin; Zeng, Jie; Yu, Haipeng; Liu, Yixing; Li, Jian

    2014-01-01

    This article describes the fabrication of nanocellulose fibers (NCFs) with different morphologies and surface properties from biomass resources as well as their self-aggregation into lightweight aerogels. By carefully modulating the nanofibrillation process, four types of NCFs could be readily fabricated, including long aggregated nanofiber bundles, long individualized nanofibers with surface C6 -carboxylate groups, short aggregated nanofibers, and short individualized nanofibers with surface sulfate groups. Free-standing lightweight aerogels were obtained from the corresponding aqueous NCF suspensions through freeze-drying. The structure of the aerogels could be controlled by manipulating the type of NCFs and the concentration of their suspensions. A possible mechanism for the self-aggregation of NCFs into two- or three-dimensional aerogel nanostructures was further proposed. Owing to web-like structure, high porosity, and high surface reactivity, the NCF aerogels exhibited high mechanical flexibility and ductility, and excellent properties for water uptake, removal of dye pollutants, and the use as thermal insulation materials. The aerogels also displayed sound-adsorption capability at high frequencies. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Bipolar mixed features - Results from the comparative effectiveness for bipolar disorder (Bipolar CHOICE) study.

    PubMed

    Tohen, Mauricio; Gold, Alexandra K; Sylvia, Louisa G; Montana, Rebecca E; McElroy, Susan L; Thase, Michael E; Rabideau, Dustin J; Nierenberg, Andrew A; Reilly-Harrington, Noreen A; Friedman, Edward S; Shelton, Richard C; Bowden, Charles L; Singh, Vivek; Deckersbach, Thilo; Ketter, Terence A; Calabrese, Joseph R; Bobo, William V; McInnis, Melvin G

    2017-08-01

    DSM-5 changed the criteria from DSM-IV for mixed features in mood disorder episodes to include non-overlapping symptoms of depression and hypomania/mania. It is unknown if, by changing these criteria, the same group would qualify for mixed features. We assessed how those meeting DSM-5 criteria for mixed features compare to those meeting DSM-IV criteria. We analyzed data from 482 adult bipolar patients in Bipolar CHOICE, a randomized comparative effectiveness trial. Bipolar diagnoses were confirmed through the MINI International Neuropsychiatric Interview (MINI). Presence and severity of mood symptoms were collected with the Bipolar Inventory of Symptoms Scale (BISS) and linked to DSM-5 and DSM-IV mixed features criteria. Baseline demographics and clinical variables were compared between mood episode groups using ANOVA for continuous variables and chi-square tests for categorical variables. At baseline, the frequency of DSM-IV mixed episodes diagnoses obtained with the MINI was 17% and with the BISS was 20%. Using DSM-5 criteria, 9% of participants met criteria for hypomania/mania with mixed features and 12% met criteria for a depressive episode with mixed features. Symptom severity was also associated with increased mixed features with a high rate of mixed features in patients with mania/hypomania (63.8%) relative to those with depression (8.0%). Data on mixed features were collected at baseline only and thus do not reflect potential patterns in mixed features within this sample across the study duration. The DSM-5 narrower, non-overlapping definition of mixed episodes resulted in fewer patients who met mixed criteria compared to DSM-IV. Copyright © 2017. Published by Elsevier B.V.

  14. Effect of windowing on lithosphere elastic thickness estimates obtained via the coherence method: Results from northern South America

    NASA Astrophysics Data System (ADS)

    Ojeda, GermáN. Y.; Whitman, Dean

    2002-11-01

    The effective elastic thickness (Te) of the lithosphere is a parameter that describes the flexural strength of a plate. A method routinely used to quantify this parameter is to calculate the coherence between the two-dimensional gravity and topography spectra. Prior to spectra calculation, data grids must be "windowed" in order to avoid edge effects. We investigated the sensitivity of Te estimates obtained via the coherence method to mirroring, Hanning and multitaper windowing techniques on synthetic data as well as on data from northern South America. These analyses suggest that the choice of windowing technique plays an important role in Te estimates and may result in discrepancies of several kilometers depending on the selected windowing method. Te results from mirrored grids tend to be greater than those from Hanning smoothed or multitapered grids. Results obtained from mirrored grids are likely to be over-estimates. This effect may be due to artificial long wavelengths introduced into the data at the time of mirroring. Coherence estimates obtained from three subareas in northern South America indicate that the average effective elastic thickness is in the range of 29-30 km, according to Hanning and multitaper windowed data. Lateral variations across the study area could not be unequivocally determined from this study. We suggest that the resolution of the coherence method does not permit evaluation of small (i.e., ˜5 km), local Te variations. However, the efficiency and robustness of the coherence method in rendering continent-scale estimates of elastic thickness has been confirmed.

  15. An Update on Phased Array Results Obtained on the GE Counter-Rotating Open Rotor Model

    NASA Technical Reports Server (NTRS)

    Podboy, Gary; Horvath, Csaba; Envia, Edmane

    2013-01-01

    Beamform maps have been generated from 1) simulated data generated by the LINPROP code and 2) actual experimental phased array data obtained on the GE Counter-rotating open rotor model. The beamform maps show that many of the tones in the experimental data come from their corresponding Mach radius. If the phased array points to the Mach radius associated with a tone then it is likely that the tone is a result of the loading and thickness noise on the blades. In this case, the phased array correctly points to where the noise is coming from and indicates the axial location of the loudest source in the image but not necessarily the correct vertical location. If the phased array does not point to the Mach radius associated with a tone then some mechanism other than loading and thickness noise may control the amplitude of the tone. In this case, the phased array may or may not point to the actual source. If the source is not rotating it is likely that the phased array points to the source. If the source is rotating it is likely that the phased array indicates the axial location of the loudest source but not necessarily the correct vertical location. These results indicate that you have to be careful in how you interpret phased array data obtained on an open rotor since they may show the tones coming from a location other than the source location. With a subsonic tip speed open rotor the tones can come form locations outboard of the blade tips. This has implications regarding noise shielding.

  16. Results of the 1979 NACUBO Comparative Performance Study and Investment Questionnaire.

    ERIC Educational Resources Information Center

    Dresner, Bruce M.

    Results of the 1979 Comparative Performance Study of the National Association of College and Business Officers are presented. The study is designed to aid administrators in evaluating the performance of their investment pools. The report covers comparative performance information and related investment performance statistics and other endowment…

  17. [Bad results obtained from the current public health policies and recommendations of hydration].

    PubMed

    San Mauro Martín, Ismael; Romo Orozco, Denisse Aracely; Mendive Dubourdieu, Paula; Garicano Vilar, Elena; Valente, Ana; Betancor, Fabiana; Morales Hurtado, Alexis Daniel; Garagarza, Cristina

    2016-07-19

    Achieving an adequate intake of water is crucial within a balanced diet. For that purpose, dietary guidelines for healthy eating and drinking are an important consideration and need to be updated and disseminated to the population. We aimed to evaluate the liquid intake habits of a Mediterranean and Latin American population (Spain-Portugal and Mexico-Uruguay) and if they support the current recommendations of hydration by the EFSA. A record of fluid intake was obtained from 1168 participants from 4 countries above; and then compared with current consensus about hydration 1600 mL/day (female) and 2000 mL/day (male). The average fluid intake slightly surpassed the recommended: mean of 2049 mL/day (2,223 mL in males, 1,938 mL in females). Portugal stood out due to its lower intake (mean of 1,365 mL/day). Water contributed the largest part to total fluid intake (37%) in all countries (mean of 1365 mL/day). Hot beverages (18%) and milk and derivates (17%) follow water in highest consumption. The 20% of males and only 0.3% of females knew recommendations of hydration, while 63.3% of males and 62% of females followed them. Only 8.4% of people who follow the recommendations know them. The people studied surpassed the recommendation, although majority they didn´t know it. Future research should examine actual beverage consumption patterns and evaluate if the current consensuses are correctly adapted to the population needs. Hydration's policies should be transmitted to the population for their knowledge and adequate compliance.

  18. Recent results obtained on the APEX 12 m antenna with the ArTeMiS prototype camera

    NASA Astrophysics Data System (ADS)

    Talvard, M.; André, P.; Rodriguez, L.; Le-Pennec, Y.; De Breuck, C.; Revéret, V.; Agnèse, P.; Boulade, O.; Doumayrou, E.; Dubreuil, D.; Ercolani, E.; Gallais, P.; Horeau, B.; Lagage, PO; Leriche, B.; Lortholary, M.; Martignac, J.; Minier, V.; Pantin, E.; Rabanus, D.; Relland, J.; Willmann, G.

    2008-07-01

    ArTeMiS is a camera designed to operate on large ground based submillimetric telescopes in the 3 atmospheric windows 200, 350 and 450 µm. The focal plane of this camera will be equipped with 5760 bolometric pixels cooled down at 300 mK with an autonomous cryogenic system. The pixels have been manufactured, based on the same technology processes as used for the Herschel-PACS space photometer. We review in this paper the present status and the future plans of this project. A prototype camera, named P-ArTeMiS, has been developed and successfully tested on the KOSMA telescope in 2006 at Gornergrat 3100m, Switzerland. Preliminary results were presented at the previous SPIE conference in Orlando (Talvard et al, 2006). Since then, the prototype camera has been proposed and successfully installed on APEX, a 12 m antenna operated by the Max Planck Institute für Radioastronomie, the European Southern Observatory and the Onsala Space Observatory on the Chajnantor site at 5100 m altitude in Chile. Two runs have been achieved in 2007, first in March and the latter in November. We present in the second part of this paper the first processed images obtained on star forming regions and on circumstellar and debris disks. Calculated sensitivities are compared with expectations. These illustrate the improvements achieved on P-ArTeMiS during the 3 experimental campaigns.

  19. Understanding AlN Obtaining Through Computational Thermodynamics Combined with Experimental Investigation

    NASA Astrophysics Data System (ADS)

    Florea, R. M.

    2017-06-01

    Basic material concept, technology and some results of studies on aluminum matrix composite with dispersive aluminum nitride reinforcement was shown. Studied composites were manufactured by „in situ” technique. Aluminum nitride (AlN) has attracted large interest recently, because of its high thermal conductivity, good dielectric properties, high flexural strength, thermal expansion coefficient matches that of Si and its non-toxic nature, as a suitable material for hybrid integrated circuit substrates. AlMg alloys are the best matrix for AlN obtaining. Al2O3-AlMg, AlN-Al2O3, and AlN-AlMg binary diagrams were thermodynamically modelled. The obtained Gibbs free energies of components, solution parameters and stoichiometric phases were used to build a thermodynamic database of AlN- Al2O3-AlMg system. Obtaining of AlN with Liquid-phase of AlMg as matrix has been studied and compared with the thermodynamic results. The secondary phase microstructure has a significant effect on the final thermal conductivity of the obtained AlN. Thermodynamic modelling of AlN-Al2O3-AlMg system provided an important basis for understanding the obtaining behavior and interpreting the experimental results.

  20. Comparison of the identification results of Candida species obtained by BD Phoenix™ and Maldi-TOF (Bruker Microflex LT Biotyper 3.1).

    PubMed

    Marucco, Andrea P; Minervini, Patricia; Snitman, Gabriela V; Sorge, Adriana; Guelfand, Liliana I; Moral, Laura López

    2018-02-05

    In patients with invasive fungal infections, the accurate and rapid identification of the genus Candida is of utmost importance since antimycotic sensitivity is closely related to the species. The aim of the present study was to compare the identification results of species of the genus Candida obtained by BD Phoenix™ (Becton Dickinson [BD]) and Maldi-TOF MS (Bruker Microflex LT Biotyper 3.1). A total of 192 isolates from the strain collection belonging to the Mycology Network of the Autonomous City of Buenos Aires, Argentina, were analyzed. The observed concordance was 95%. Only 10 strains (5%) were not correctly identified by the BD Phoenix™ system. The average identification time with the Yeast ID panels was 8h 22min. The BD Phoenix™ system proved to be a simple, reliable and effective method for identifying the main species of the genus Candida. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. How To Obtain Aerial Photographs

    USGS Publications Warehouse

    ,

    1999-01-01

    The U.S. Geological Survey (USGS) maintains an informational data base of aerial photographic coverage of the United States and its territories that dates back to the 1940?s. This information describes photographic projects from the USGS, other Federal, State, and local government agencies, and commercial firms. The pictures on this page show a part of a standard 9- by 9-inch photograph and the results obtained by enlarging the original photograph two and four times. Compare the size of the Qualcomm Stadium, Jack Murphy Field, in San Diego, Calif, and the adjacent parking lot and freeways shown at the different scales. USGS Earth Science Information Center (ESIC) representatives will assist you in locating and ordering photographs. Please submit the completed checklist and a marked map showing your area of interest to any ESIC.

  2. Trained nurses can obtain satisfactory bone marrow aspirates and trephine biopsies.

    PubMed Central

    Lawson, S; Aston, S; Baker, L; Fegan, C D; Milligan, D W

    1999-01-01

    AIMS: To assess the feasibility of training nurse practitioners to perform bone marrow aspiration and trephine biopsy, and to compare the quality of these samples with those obtained by medical staff. METHODS: A retrospective audit was undertaken of nurse practitioner and medical staff performance in bone marrow procedures in a busy haematology day unit. RESULTS: Nurse practitioners fared favourably in comparison with medical staff in performing bone marrow trephine biopsies, with mean biopsy lengths of 11 mm and 10.7 mm respectively. However, only 78% of the smears obtained by the nurses were judged technically satisfactory, compared with 91% prepared by doctors. This discrepancy was thought to be due largely to the quality of slide spreading. CONCLUSIONS: With motivated staff and a structured educational and training programme it is possible for nurse practitioners to perform the techniques of bone marrow aspiration and biopsy, and obtain specimens of satisfactory quality, thus improving efficiency of the haematology day unit and increasing quality of patient care. Images PMID:10396248

  3. Evaluation of a statistics-based Ames mutagenicity QSAR model and interpretation of the results obtained.

    PubMed

    Barber, Chris; Cayley, Alex; Hanser, Thierry; Harding, Alex; Heghes, Crina; Vessey, Jonathan D; Werner, Stephane; Weiner, Sandy K; Wichard, Joerg; Giddings, Amanda; Glowienke, Susanne; Parenty, Alexis; Brigo, Alessandro; Spirkl, Hans-Peter; Amberg, Alexander; Kemper, Ray; Greene, Nigel

    2016-04-01

    The relative wealth of bacterial mutagenicity data available in the public literature means that in silico quantitative/qualitative structure activity relationship (QSAR) systems can readily be built for this endpoint. A good means of evaluating the performance of such systems is to use private unpublished data sets, which generally represent a more distinct chemical space than publicly available test sets and, as a result, provide a greater challenge to the model. However, raw performance metrics should not be the only factor considered when judging this type of software since expert interpretation of the results obtained may allow for further improvements in predictivity. Enough information should be provided by a QSAR to allow the user to make general, scientifically-based arguments in order to assess and overrule predictions when necessary. With all this in mind, we sought to validate the performance of the statistics-based in vitro bacterial mutagenicity prediction system Sarah Nexus (version 1.1) against private test data sets supplied by nine different pharmaceutical companies. The results of these evaluations were then analysed in order to identify findings presented by the model which would be useful for the user to take into consideration when interpreting the results and making their final decision about the mutagenic potential of a given compound. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The relative ease of obtaining a dermatologic appointment in Boston: how methods drive results.

    PubMed

    Weingold, David Howard; Lack, Michael Dweight; Yanowitz, Karen Leslie

    2009-06-01

    Recent reports have indicated long wait times for dermatologic appointments even for changing moles. Our objective was to determine the wait time for a person willing to make multiple calls and accept an appointment from any dermatologist at any satellite location for a changing mole from a dermatologist who advertised in a Boston, MA, telephone book. We telephoned each practice listed in a Boston, MA, telephone book. Patients making one call to each dermatologic practice on average obtained an appointment in 18 days. Patients calling two practices were offered an appointment on average in 7 days. Patients calling 3 practices were also offered an appointment in 1 week. We only telephoned practices listed in a Boston, MA, telephone book and we only surveyed one urban area. These results suggest that a reasonable concerned patient who was willing to make multiple calls to different providers in Boston, MA, can be seen in a timely fashion.

  5. Quantitative assessment of the impact of biomedical image acquisition on the results obtained from image analysis and processing.

    PubMed

    Koprowski, Robert

    2014-07-04

    Dedicated, automatic algorithms for image analysis and processing are becoming more and more common in medical diagnosis. When creating dedicated algorithms, many factors must be taken into consideration. They are associated with selecting the appropriate algorithm parameters and taking into account the impact of data acquisition on the results obtained. An important feature of algorithms is the possibility of their use in other medical units by other operators. This problem, namely operator's (acquisition) impact on the results obtained from image analysis and processing, has been shown on a few examples. The analysed images were obtained from a variety of medical devices such as thermal imaging, tomography devices and those working in visible light. The objects of imaging were cellular elements, the anterior segment and fundus of the eye, postural defects and others. In total, almost 200'000 images coming from 8 different medical units were analysed. All image analysis algorithms were implemented in C and Matlab. For various algorithms and methods of medical imaging, the impact of image acquisition on the results obtained is different. There are different levels of algorithm sensitivity to changes in the parameters, for example: (1) for microscope settings and the brightness assessment of cellular elements there is a difference of 8%; (2) for the thyroid ultrasound images there is a difference in marking the thyroid lobe area which results in a brightness assessment difference of 2%. The method of image acquisition in image analysis and processing also affects: (3) the accuracy of determining the temperature in the characteristic areas on the patient's back for the thermal method - error of 31%; (4) the accuracy of finding characteristic points in photogrammetric images when evaluating postural defects - error of 11%; (5) the accuracy of performing ablative and non-ablative treatments in cosmetology - error of 18% for the nose, 10% for the cheeks, and 7% for the

  6. Improved dielectric functions in metallic films obtained via template stripping

    NASA Astrophysics Data System (ADS)

    Hyuk Park, Jong; Nagpal, Prashant; Oh, Sang-Hyun; Norris, David J.

    2012-02-01

    We compare the dielectric functions of silver interfaces obtained via thermal evaporation with those obtained with template stripping. Ellipsometry measurements show that the smoother template-stripped surfaces exhibit effective dielectric functions with a more negative real component and a smaller imaginary component, implying higher conductivity and less energy loss, respectively. These results agree with the relation between dielectric function and surface roughness derived from combining the effective-medium model and the Drude-Lorentz model. The improvement in the effective dielectric properties shows that metallic films prepared via template stripping can be favorable for applications in electronics, nanophotonics, and plasmonics.

  7. Saturn gravity results obtained from Pioneer 11 tracking data and earth-based Saturn satellite data

    NASA Technical Reports Server (NTRS)

    Null, G. W.; Lau, E. L.; Biller, E. D.; Anderson, J. D.

    1981-01-01

    Improved gravity coefficients for Saturn, its satellites and rings are calculated on the basis of a combination of Pioneer 11 spacecraft Doppler tracking data and earth-based determinations of Saturn natural satellite apse and node rates. Solutions are first obtained separately from the coherent Doppler tracking data obtained for the interval from August 20 to September 4, surrounding the time of closest approach, with the effects of solar plasma on radio signal propagation taken into account, and from secular rates for Mimas, Enceladus, Tethys, Dione, Rhea and Titan determined from astrometric data by Kozai (1957, 1976) and Garcia (1972). Combination of the data by the use of the Pioneer solution and corresponding unadjusted covariance matrix as a priori information for a secular rate analysis results in values for the total ring mass of essentially zero at a standard error level of 1.7 x 10 to the -6th Saturn masses, a ratio of solar mass to that of the Saturn system of 3498.09 + or - 0.22, masses of Rhea, Titan and Iapetus of 4.0 + or - 0.9, 238.8 + or - 3, and 3.4 + or - 1.3 x 10 to the -6th Saturn masses, respectively, and second and fourth zonal harmonics of 16,479 + or - 18 and -937 + or - 38, respectively. The harmonic coefficients are noted to be important as boundary conditions in the modeling of the Saturn interior.

  8. Ink dating using thermal desorption and gas chromatography/mass spectrometry: comparison of results obtained in two laboratories.

    PubMed

    Koenig, Agnès; Bügler, Jürgen; Kirsch, Dieter; Köhler, Fritz; Weyermann, Céline

    2015-01-01

    An ink dating method based on solvent analysis was recently developed using thermal desorption followed by gas chromatography/mass spectrometry (GC/MS) and is currently implemented in several forensic laboratories. The main aims of this work were to implement this method in a new laboratory to evaluate whether results were comparable at three levels: (i) validation criteria, (ii) aging curves, and (iii) results interpretation. While the results were indeed comparable in terms of validation, the method proved to be very sensitive to maintenances. Moreover, the aging curves were influenced by ink composition, as well as storage conditions (particularly when the samples were not stored in "normal" room conditions). Finally, as current interpretation models showed limitations, an alternative model based on slope calculation was proposed. However, in the future, a probabilistic approach may represent a better solution to deal with ink sample inhomogeneity. © 2014 American Academy of Forensic Science.

  9. Measurement results obtained from air quality monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracowmore » area could be more intelligible.« less

  10. Comparative data compression techniques and multi-compression results

    NASA Astrophysics Data System (ADS)

    Hasan, M. R.; Ibrahimy, M. I.; Motakabber, S. M. A.; Ferdaus, M. M.; Khan, M. N. H.

    2013-12-01

    Data compression is very necessary in business data processing, because of the cost savings that it offers and the large volume of data manipulated in many business applications. It is a method or system for transmitting a digital image (i.e., an array of pixels) from a digital data source to a digital data receiver. More the size of the data be smaller, it provides better transmission speed and saves time. In this communication, we always want to transmit data efficiently and noise freely. This paper will provide some compression techniques for lossless text type data compression and comparative result of multiple and single compression, that will help to find out better compression output and to develop compression algorithms.

  11. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques.

    PubMed

    Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed

    2017-01-01

    Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.

  12. Comparing measurement response and inverted results of electrical resistivity tomography instruments

    USGS Publications Warehouse

    Parsekian, Andrew D.; Claes, Niels; Singha, Kamini; Minsley, Burke J.; Carr, Bradley; Voytek, Emily; Harmon, Ryan; Kass, Andy; Carey, Austin; Thayer, Drew; Flinchum, Brady

    2017-01-01

    In this investigation, we compare the results of electrical resistivity measurements made by six commercially available instruments on the same line of electrodes to determine if there are differences in the measured data or inverted results. These comparisons are important to determine whether measurements made between different instruments are consistent. We also degraded contact resistance on one quarter of the electrodes to study how each instrument responds to different electrical connection with the ground. We find that each instrument produced statistically similar apparent resistivity results, and that any conservative assessment of the final inverted resistivity models would result in a similar interpretation for each. We also note that inversions, as expected, are affected by measurement error weights. Increased measurement errors were most closely associated with degraded contact resistance in this set of experiments. In a separate test we recorded the full measured waveform for a single four-electrode array to show how poor electrode contact and instrument-specific recording settings can lead to systematic measurement errors. We find that it would be acceptable to use more than one instrument during an investigation with the expectation that the results would be comparable assuming contact resistance remained consistent.

  13. Wood-Polymer composites obtained by gamma irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gago, J.; Lopez, A.; Rodriguez, J.

    2007-10-26

    In this work we impregnate three Peruvian woods (Calycophy spruceanum Be, Aniba amazonica Meiz and Hura crepitans L) with styrene-polyester resin and methyl methacrylate. The polymerization of the system was promoted by gamma radiation and the experimental optimal condition was obtained with styrene-polyester 1:1 and 15 kGy. The obtained composites show reduced water absorption and better mechanical properties compared to the original wood. The structure of the wood-polymer composites was studied by light microscopy. Water absorption and hardness were also obtained.

  14. Experimental Results Obtained with Air Liquide Cold Compression System: CERN LHC and SNS Projects

    NASA Astrophysics Data System (ADS)

    Delcayre, F.; Courty, J.-C.; Hamber, F.; Hilbert, B.; Monneret, E.; Toia, J.-L.

    2006-04-01

    Large scale collider facilities will make intensive use of superconducting magnets, operating below 2.0 K. This dictates high-capacity refrigeration systems operating below 2.0 K. These systems, making use of cryogenic centrifugal compressors in a series arrangement with room temperature screw compressors will be coupled to a refrigerator, providing a certain power at 4.5 K. A first Air Liquide Cold Compression System (CCS) unit was built and delivered to CERN in 2001. Installed at the beginning of 2002, it was commissioned and tested successfully during year 2002. A series of four sets of identical CCS were then tested in 2004. Another set of four cryogenic centrifugal compressors (CCC) has been delivered to Thomas Jefferson National Accelerator Facility (JLAB) for the Spallation Neutron Source (SNS) in 2002. These compressors were tested and commissioned from December 2004 to July 2005. The experimental results obtained with these systems will be presented and discussed: the characteristics of the CCC will be detailed. The principles of control for the CCC in series will be detailed.

  15. Quality assessment of DInSAR deformation measurements in volcanic areas by comparing GPS and SBAS results

    NASA Astrophysics Data System (ADS)

    Bonforte, A.; Casu, F.; de Martino, P.; Guglielmino, F.; Lanari, R.; Manzo, M.; Obrizzo, F.; Puglisi, G.; Sansosti, E.; Tammaro, U.

    2009-04-01

    Differential Synthetic Aperture Radar Interferometry (DInSAR) is a methodology able to measure ground deformation rates and time series of relatively large areas. Several different approaches have been developed over the past few years: they all have in common the capability to measure deformations on a relatively wide area (say 100 km by 100 km) with a high density of the measuring points. For these reasons, DInSAR represents a very useful tool for investigating geophysical phenomena, with particular reference to volcanic areas. As for any measuring technique, the knowledge of the attainable accuracy is of fundamental importance. In the case of DInSAR technology, we have several error sources, such as orbital inaccuracies, phase unwrapping errors, atmospheric artifacts, effects related to the reference point selection, thus making very difficult to define a theoretical error model. A practical way to obtain assess the accuracy is to compare DInSAR results with independent measurements, such as GPS or levelling. Here we present an in-deep comparison between the deformation measurement obtained by exploiting the DInSAR technique referred to as Small BAseline Subset (SBAS) algorithm and by continuous GPS stations. The selected volcanic test-sites are Etna, Vesuvio and Campi Flegrei, in Italy. From continuous GPS data, solutions are computed at the same days SAR data are acquired for direct comparison. Moreover, three dimensional GPS displacement vectors are projected along the radar line of sight of both ascending and descending acquisition orbits. GPS data are then compared with the coherent DInSAR pixels closest to the GPS station. Relevant statistics of the differences between the two measurements are computed and correlated to some scene parameter that may affect DInSAR accuracy (altitude, terrain slope, etc.).

  16. Comparative Soot Diagnostics: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Urban, David L.; Griffin, DeVon W.; Gard, Melissa Y.

    1997-01-01

    The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be

  17. Can different primary care databases produce comparable estimates of burden of disease: results of a study exploring venous leg ulceration.

    PubMed

    Petherick, Emily S; Pickett, Kate E; Cullum, Nicky A

    2015-08-01

    Primary care databases from the UK have been widely used to produce evidence on the epidemiology and health service usage of a wide range of conditions. To date there have been few evaluations of the comparability of estimates between different sources of these data. To estimate the comparability of two widely used primary care databases, the Health Improvement Network Database (THIN) and the General Practice Research Database (GPRD) using venous leg ulceration as an exemplar condition. Cross prospective cohort comparison. GPRD and the THIN databases using data from 1998 to 2006. A data set was extracted from both databases containing all cases of persons aged 20 years or greater with a database diagnosis of venous leg ulceration recorded in the databases for the period 1998-2006. Annual rates of incidence and prevalence of venous leg ulceration were calculated within each database and standardized to the European standard population and compared using standardized rate ratios. Comparable estimates of venous leg ulcer incidence from the GPRD and THIN databases could be obtained using data from 2000 to 2006 and of prevalence using data from 2001 to 2006. Recent data collected by these two databases are more likely to produce comparable results of the burden venous leg ulceration. These results require confirmation in other disease areas to enable researchers to have confidence in the comparability of findings from these two widely used primary care research resources. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Paternity tests in Mexico: Results obtained in 3005 cases.

    PubMed

    García-Aceves, M E; Romero Rentería, O; Díaz-Navarro, X X; Rangel-Villalobos, H

    2018-04-01

    National and international reports regarding the paternity testing activity scarcely include information from Mexico and other Latin American countries. Therefore, we report different results from the analysis of 3005 paternity cases analyzed during a period of five years in a Mexican paternity testing laboratory. Motherless tests were the most frequent (77.27%), followed by trio cases (20.70%); the remaining 2.04% included different cases of kinship reconstruction. The paternity exclusion rate was 29.58%, higher but into the range reported by the American Association of Blood Banks (average 24.12%). We detected 65 mutations, most of them involving one-step (93.8% and the remaining were two-step mutations (6.2%) thus, we were able to estimate the paternal mutation rate for 17 different STR loci: 0.0018 (95% CI 0.0005-0.0047). Five triallelic patterns and 12 suspected null alleles were detected during this period; however, re-amplification of these samples with a different Human Identification (HID) kit confirmed the homozygous genotypes, which suggests that most of these exclusions actually are one-step mutations. HID kits with ≥20 STRs detected more exclusions, diminishing the rate of inconclusive results with isolated exclusions (<3 loci), and leading to higher paternity indexes (PI). However, the Powerplex 21 kit (20 STRs) and Powerplex Fusion kit (22 STRs) offered similar PI (p = 0.379) and average number of exclusions (PE) (p = 0.339) when a daughter was involved in motherless tests. In brief, besides to report forensic parameters from paternity tests in Mexico, results describe improvements to solve motherless paternity tests using HID kits with ≥20 STRs instead of one including 15 STRs. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  19. Comparative morphometry of facial surface models obtained from a stereo vision system in a healthy population

    NASA Astrophysics Data System (ADS)

    López, Leticia; Gastélum, Alfonso; Chan, Yuk Hin; Delmas, Patrice; Escorcia, Lilia; Márquez, Jorge

    2014-11-01

    Our goal is to obtain three-dimensional measurements of craniofacial morphology in a healthy population, using standard landmarks established by a physical-anthropology specialist and picked from computer reconstructions of the face of each subject. To do this, we designed a multi-stereo vision system that will be used to create a data base of human faces surfaces from a healthy population, for eventual applications in medicine, forensic sciences and anthropology. The acquisition process consists of obtaining the depth map information from three points of views, each depth map is obtained from a calibrated pair of cameras. The depth maps are used to build a complete, frontal, triangular-surface representation of the subject face. The triangular surface is used to locate the landmarks and the measurements are analyzed with a MATLAB script. The classification of the subjects was done with the aid of a specialist anthropologist that defines specific subject indices, according to the lengths, areas, ratios, etc., of the different structures and the relationships among facial features. We studied a healthy population and the indices from this population will be used to obtain representative averages that later help with the study and classification of possible pathologies.

  20. Feasibility and accuracy of molecular testing in specimens obtained with small biopsy forceps: comparison with the results of surgical specimens.

    PubMed

    Oki, Masahide; Yatabe, Yasushi; Saka, Hideo; Kitagawa, Chiyoe; Kogure, Yoshihito; Ichihara, Shu; Moritani, Suzuko

    2015-01-01

    During bronchoscopy, small biopsy forceps are increasingly used for the diagnosis of peripheral pulmonary lesions. However, it is unclear whether the formalin-fixed paraffin-embedded specimens sampled with the small biopsy forceps are suitable for the determination of genotypes which become indispensable for the management decision regarding patients with non-small cell lung cancer. The aim of this study was to evaluate the feasibility and accuracy of molecular testing in the specimens obtained with 1.5-mm small biopsy forceps. We examined specimens in 91 patients, who were enrolled in our previous 3 studies on the usefulness of thin bronchoscopes and given a diagnosis of non-small cell lung cancer by bronchoscopy with the 1.5-mm biopsy forceps, and then underwent surgical resection. An experienced pathologist examined paraffin-embedded specimens obtained by bronchoscopic biopsy or surgical resection in a blind fashion on epidermal growth factor receptor (EGFR) mutations, anaplastic lymphoma kinase (ALK) rearrangements and KRAS mutations. Twenty-five (27%), 2 (2%) and 5 (5%) patients had an EGFR mutation, ALK rearrangement and KRAS mutation, respectively, based on the results in surgical specimens. EGFR, ALK and KRAS testing with bronchoscopic specimens was feasible in 82 (90%), 86 (95%) and 83 (91%) patients, respectively. If molecular testing was feasible, the accuracy of EGFR, ALK and KRAS testing with bronchoscopic specimens for the results with surgical specimens was 98, 100 and 98%, respectively. The results of molecular testing in the formalin-fixed paraffin-embedded specimens obtained with the small forceps, in which the genotype could be evaluated, correlated well with those in surgically resected specimens.

  1. A validation study comparing self-reported travel diaries and objective data obtained from in-vehicle monitoring devices in older drivers with bilateral cataract.

    PubMed

    Agramunt, Seraina; Meuleners, Lynn; Chow, Kyle Chi; Ng, Jonathon Q; Morlet, Nigel

    2017-09-01

    Advances in technology have made it possible to examine real-world driving using naturalistic data obtained from in-vehicle monitoring devices. These devices overcome the weaknesses of self-report methods and can provide comprehensive insights into driving exposure, habits and practices of older drivers. The aim of this study is to compare self-reported and objectively measured driving exposure, habits and practices using a travel diary and an in-vehicle driver monitoring device in older drivers with bilateral cataract. A cross-sectional study was undertaken. Forty seven participants aged 58-89 years old (mean=74.1; S.D.=7.73) were recruited from three eye clinics over a one year period. Data collection consisted of a cognitive test, a researcher-administered questionnaire, a travel diary and an in-vehicle monitoring device. Participants' driving exposure and patterns were recorded for one week using in-vehicle monitoring devices. They also completed a travel diary each time they drove a motor vehicle as the driver. Paired t-tests were used to examine differences/agreement between the two instruments under different driving circumstances. The data from the older drivers' travel diaries significantly underestimated the number of overall trips (p<0.001), weekend trips (p=0.002) and trips during peak hour (p=0.004). The travel diaries also significantly overestimated overall driving duration (p<0.001) and weekend driving duration (p=0.003), compared to the data obtained from the in-vehicle monitoring devices. No significant differences were found between instruments for kilometres travelled under any of the driving circumstances. The results of this study found that relying solely on self-reported travel diaries to assess driving outcomes may not be accurate, particularly for estimates of the number of trips made and duration of trips. The clear advantages of using in-vehicle monitoring devices over travel diaries to monitor driving habits and exposure among an older

  2. Comparison of the Calculations Results of Heat Exchange Between a Single-Family Building and the Ground Obtained with the Quasi-Stationary and 3-D Transient Models. Part 2: Intermittent and Reduced Heating Mode

    NASA Astrophysics Data System (ADS)

    Staszczuk, Anna

    2017-03-01

    The paper provides comparative results of calculations of heat exchange between ground and typical residential buildings using simplified (quasi-stationary) and more accurate (transient, three-dimensional) methods. Such characteristics as building's geometry, basement hollow and construction of ground touching assemblies were considered including intermittent and reduced heating mode. The calculations with simplified methods were conducted in accordance with currently valid norm: PN-EN ISO 13370:2008. Thermal performance of buildings. Heat transfer via the ground. Calculation methods. Comparative estimates concerning transient, 3-D, heat flow were performed with computer software WUFI®plus. The differences of heat exchange obtained using more exact and simplified methods have been specified as a result of the analysis.

  3. Comparison between Measurements Obtained with three Different Perineometers

    PubMed Central

    Barbosa, Patrícia Brentegani; Franco, Maíra Menezes; de Oliveira Souza, Flaviane; Antônio, Flávia Ignácio; Montezuma, Thaís; Ferreira, Cristine Homsi Jorge

    2009-01-01

    OBJECTIVE: To analyze the results obtained in the evaluation of intra-vaginal pressure using three different brands of perineometers in nulliparous volunteers. MATERIALS AND METHODS: Twenty nulliparous women with no anatomical alterations and/or dysfunction of the pelvic floor were enrolled in our study. All the women had the ability to voluntarily contract their PFM (Pelvic Floor Muscles), as assessed by digital palpation. The intra-vaginal pressure was assessed using three different brands of perineometer (Neurodyn Evolution™, SensuPower™ and Peritron™). Each volunteer was evaluated on three alternate days by a single examiner using a single brand of perineometer on each day. In the assessment, the volunteers were required to pull (contract) their PFM in and up as strongly as possible 3 times and to sustain the contraction for 5 seconds, with an interval of 30 seconds between each pull. For the statistical analysis, a concordance correlation coefficient was used to compare the values that were obtained with each brand of perineometer. RESULTS: A moderate concordance (0.51) was found between the results from the Peritron™ and Neurodyn™ perineometers, a fair concordance (0.21) between the Peritron™ and SensuPower™ brands and a poor concordance (0.19) between the Neurodyn™ and SensuPower™ brands. CONCLUSION: The concordance of the measurements of the intra-vaginal pressure ranged from poor to moderate, suggesting that perineometers of different brands generate different results. PMID:19578656

  4. First results obtained within the European 'LAMA' programme (Large Active Mirrors in Aluminium)

    NASA Astrophysics Data System (ADS)

    Rozelot, J.-P.

    1993-11-01

    To investigate the feasibility of large size aluminum mirrors, studies have been undertaken in cooperation with European Southern Observatory (ESO), in the framework of a European program. The first phase, which is just now ended, addressed the following items: (1) tests to select the best aluminum alloy, (2) aluminum welding, homogeneity and stability, (3) aluminum high-precision machining, (4) nickel coating, (5) polishing of the nickel layer, (6) active optics. Furthermore, tests have been conducted to demonstrate that the quality of the mirrors is not altered at various temperatures and after a large number of aluminizing and cleaning cycles (corresponding to about 50 years' life). The mirror shape (whose specifications are fully compliant with those of the Very Large Telescope (VLT), as the program is conducted in cooperation with ESO) was computed under several causes of deformations: evidencing gravity as the predominant effect, and very low distortions as the high thermal conductivity limits the thermal transverse gradient to 0.025 C. Results show that it is quite possible to obtain high optical quality mirrors, mainly due to recent progress both in metallurgical processes (high precision machining -7 microns rms-) and active optics, that permit to correct residual aberrations of the surface. Such an alternative to classical glass mirrors will presently stand as a safe, economical solution that saves manufacturing time, for monolithic or segmented mirrors for innovative telescopes (e.g., lunar interferometric network).

  5. Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study.

    PubMed

    Piscaglia, Fabio; Salvatore, Veronica; Mulazzani, Lorenzo; Cantisani, Vito; Colecchia, Antonio; Di Donato, Roberto; Felicani, Cristina; Ferrarini, Alessia; Gamal, Nesrine; Grasso, Valentina; Marasco, Giovanni; Mazzotta, Elena; Ravaioli, Federico; Ruggieri, Giacomo; Serio, Ilaria; Sitouok Nkamgho, Joules Fabrice; Serra, Carla; Festi, Davide; Schiavone, Cosima; Bolondi, Luigi

    2017-07-01

    Whether Fibroscan thresholds can be immediately adopted for none, some or all other shear wave elastography techniques has not been tested. The aim of the present study was to test the concordance of the findings obtained from 7 of the most recent ultrasound elastography machines with respect to Fibroscan. Sixteen hepatitis C virus-related patients with fibrosis ≥2 and having reliable results at Fibroscan were investigated in two intercostal spaces using 7 different elastography machines. Coefficients of both precision (an index of data dispersion) and accuracy (an index of bias correction factors expressing different magnitudes of changes in comparison to the reference) were calculated. Median stiffness values differed among the different machines as did coefficients of both precision (range 0.54-0.72) and accuracy (range 0.28-0.87). When the average of the measurements of two intercostal spaces was considered, coefficients of precision significantly increased with all machines (range 0.72-0.90) whereas of accuracy improved more scatteredly and by a smaller degree (range 0.40-0.99). The present results showed only moderate concordance of the majority of elastography machines with the Fibroscan results, preventing the possibility of the immediate universal adoption of Fibroscan thresholds for defining liver fibrosis staging for all new machines. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  6. Results from CrIS/ATMS Obtained Using an AIRS "Version-6 Like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena

    2015-01-01

    We have tested and evaluated Version-6.22 AIRS and Version-6.22 CrIS products on a single day, December 4, 2013, and compared results to those derived using AIRS Version-6. AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6All AIRS and CrIS products agree reasonably well with each other CrIS Version-6.22 T(p) and q(p) results are slightly poorer than AIRS under very cloudy conditions. Both AIRS and CrIS Version-6.22 run now at JPL. Our short term plans are to analyze many common months at JPL in the near future using Version-6.22 or a further improved algorithm to assess the compatibility of AIRS and CrIS monthly mean products and their interannual differencesUpdates to the calibration of both CrIS and ATMS are still being finalized. JPL plans, in collaboration with the Goddard DISC, to reprocess all AIRS data using a still to be finalized Version-7 retrieval algorithm, and to reprocess all recalibrated CrISATMS data using Version-7 as well.

  7. Results from CrIS/ATMS Obtained Using an AIRS "Version-6 like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena

    2015-01-01

    We tested and evaluated Version-6.22 AIRS and Version-6.22 CrIS products on a single day, December 4, 2013, and compared results to those derived using AIRS Version-6. AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6All AIRS and CrIS products agree reasonably well with each other. CrIS Version-6.22 T(p) and q(p) results are slightly poorer than AIRS over land, especially under very cloudy conditions. Both AIRS and CrIS Version-6.22 run now at JPL. Our short term plans are to analyze many common months at JPL in the near future using Version-6.22 or a further improved algorithm to assess the compatibility of AIRS and CrIS monthly mean products and their interannual differences. Updates to the calibration of both CrIS and ATMS are still being finalized. JPL plans, in collaboration with the Goddard DISC, to reprocess all AIRS data using a still to be finalized Version-7 retrieval algorithm, and to reprocess all recalibrated CrISATMS data using Version-7 as well.

  8. Standardization of a fluconazole bioassay and correlation of results with those obtained by high-pressure liquid chromatography.

    PubMed Central

    Rex, J H; Hanson, L H; Amantea, M A; Stevens, D A; Bennett, J E

    1991-01-01

    An improved bioassay for fluconazole was developed. This assay is sensitive in the clinically relevant range (2 to 40 micrograms/ml) and analyzes plasma, serum, and cerebrospinal fluid specimens; bioassay results correlate with results obtained by high-pressure liquid chromatography (HPLC). Bioassay and HPLC analyses of spiked plasma, serum, and cerebrospinal fluid samples (run as unknowns) gave good agreement with expected values. Analysis of specimens from patients gave equivalent results by both HPLC and bioassay. HPLC had a lower within-run coefficient of variation (less than 2.5% for HPLC versus less than 11% for bioassay) and a lower between-run coefficient of variation (less than 5% versus less than 12% for bioassay) and was more sensitive (lower limit of detection, 0.1 micrograms/ml [versus 2 micrograms/ml for bioassay]). The bioassay is, however, sufficiently accurate and sensitive for clinical specimens, and its relative simplicity, low sample volume requirement, and low equipment cost should make it the technique of choice for analysis of routine clinical specimens. PMID:1854166

  9. Comparison of the depth of an optic nerve head obtained using stereo retinal images and HRT

    NASA Astrophysics Data System (ADS)

    Nakagawa, Toshiaki; Hayashi, Yoshinori; Hatanaka, Yuji; Aoyama, Akira; Hara, Takeshi; Kakogawa, Masakatsu; Fujita, Hiroshi; Yamamoto, Tetsuya

    2007-03-01

    The analysis of the optic nerve head (ONH) in the retinal fundus is important for the early detection of glaucoma. In this study, we investigate an automatic reconstruction method for producing the 3-D structure of the ONH from a stereo retinal image pair; the depth value of the ONH measured by using this method was compared with the measurement results determined from the Heidelberg Retina Tomograph (HRT). We propose a technique to obtain the depth value from the stereo image pair, which mainly consists of four steps: (1) cutout of the ONH region from the retinal images, (2) registration of the stereo pair, (3) disparity detection, and (4) depth calculation. In order to evaluate the accuracy of this technique, the shape of the depression of an eyeball phantom that had a circular dent as generated from the stereo image pair and used to model the ONH was compared with a physically measured quantity. The measurement results obtained when the eyeball phantom was used were approximately consistent. The depth of the ONH obtained using the stereo retinal images was in accordance with the results obtained using the HRT. These results indicate that the stereo retinal images could be useful for assessing the depth of the ONH for the diagnosis of glaucoma.

  10. An innovative recycling process to obtain pure polyethylene and polypropylene from household waste.

    PubMed

    Serranti, Silvia; Luciani, Valentina; Bonifazi, Giuseppe; Hu, Bin; Rem, Peter C

    2015-01-01

    An innovative recycling process, based on magnetic density separation (MDS) and hyperspectral imaging (HSI), to obtain high quality polypropylene and polyethylene as secondary raw materials, is presented. More in details, MDS was applied to two different polyolefin mixtures coming from household waste. The quality of the two separated PP and PE streams, in terms of purity, was evaluated by a classification procedure based on HSI working in the near infrared range (1000-1700 nm). The classification model was built using known PE and PP samples as training set. The results obtained by HSI were compared with those obtained by classical density analysis carried in laboratory on the same polymers. The results obtained by MDS and the quality assessment of the plastic products by HSI showed that the combined action of these two technologies is a valid solution that can be implemented at industrial level. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Social inclusion of the people with mental health issues: Compare international results.

    PubMed

    Santos, Jussara Carvalho Dos; Barros, Sônia; Huxley, Peter John

    2018-06-01

    Social inclusion of people with mental health issues is an aim of the World Health Organisation. Many countries have adopted that objective, including Brazil and the United Kingdom and both have focused treatment in the community. The aim of this article is to compare international results using the same inclusion instrument. The samples in this study were 225 people with mental health issues in community services in São Paulo, Brazil. Their results are compared to findings from 168 people with similar mental health issues in Hong Kong, China, and from the United Kingdom - a nationally representative sample of 212 people without mental health issues. The instrument used to measure a social inclusion called Social and Communities Opportunities Profile (SCOPE) has been validated for use in the United Kingdom, China and Brazil. The results are that people with mental health issues have worse social inclusion when compared to general population. Between the people with mental health issues, the sample of São Paulo has the lowest social inclusion index but, in relation to access to the Brazilian revised mental health services, that sample has a similarly high inclusion rating to the general population of the United Kingdom. Findings are important to understand mental health in the community context, as well as their adversities and potentialities.

  12. Health Outcomes of Obtaining Housing Among Older Homeless Adults.

    PubMed

    Brown, Rebecca T; Miao, Yinghui; Mitchell, Susan L; Bharel, Monica; Patel, Mitkumar; Ard, Kevin L; Grande, Laura J; Blazey-Martin, Deborah; Floru, Daniella; Steinman, Michael A

    2015-07-01

    We determined the impact of obtaining housing on geriatric conditions and acute care utilization among older homeless adults. We conducted a 12-month prospective cohort study of 250 older homeless adults recruited from shelters in Boston, Massachusetts, between January and June 2010. We determined housing status at follow-up, determined number of emergency department visits and hospitalizations over 12 months, and examined 4 measures of geriatric conditions at baseline and 12 months. Using multivariable regression models, we evaluated the association between obtaining housing and our outcomes of interest. At 12-month follow-up, 41% of participants had obtained housing. Compared with participants who remained homeless, those with housing had fewer depressive symptoms. Other measures of health status did not differ by housing status. Participants who obtained housing had a lower rate of acute care use, with an adjusted annualized rate of acute care visits of 2.5 per year among participants who obtained housing and 5.3 per year among participants who remained homeless. Older homeless adults who obtained housing experienced improved depressive symptoms and reduced acute care utilization compared with those who remained homeless.

  13. A conversion formula for comparing pulse oximeter desaturation rates obtained with different averaging times.

    PubMed

    Vagedes, Jan; Bialkowski, Anja; Wiechers, Cornelia; Poets, Christian F; Dietz, Klaus

    2014-01-01

    The number of desaturations determined in recordings of pulse oximeter saturation (SpO2) primarily depends on the time over which values are averaged. As the averaging time in pulse oximeters is not standardized, it varies considerably between centers. To make SpO2 data comparable, it is thus desirable to have a formula that allows conversion between desaturation rates obtained using different averaging times for various desaturation levels and minimal durations. Oxygen saturation was measured for 170 hours in 12 preterm infants with a mean number of 65 desaturations <90% per hour of arbitrary duration by using a pulse oximeter in a 2-4 s averaging mode. Using 7 different averaging times between 3 and 16 seconds, the raw red-to-infrared data were reprocessed to determine the number of desaturations (D). The whole procedure was carried out for 7 different minimal desaturation durations (≥ 1, ≥ 5, ≥ 10, ≥ 15, ≥ 20, ≥ 25, ≥ 30 s) below SpO2 threshold values of 80%, 85% or 90% to finally reach a conversion formula. The formula was validated by splitting the infants into two groups of six children each and using one group each as a training set and the other one as a test set. Based on the linear relationship found between the logarithm of the desaturation rate and the logarithm of the averaging time, the conversion formula is: D2 = D1 (T2/T1)(c), where D2 is the desaturation rate for the desired averaging time T2, and D1 is the desaturation rate for the original averaging time T1, with the exponent c depending on the desaturation threshold and the minimal desaturation duration. The median error when applying this formula was 2.6%. This formula enables the conversion of desaturation rates between different averaging times for various desaturation thresholds and minimal desaturation durations.

  14. Thermoelectric generator based on composites obtained by sintering of detonation nanodiamonds

    NASA Astrophysics Data System (ADS)

    Eidelman, E. D.; Meilakhs, A. P.; Semak, B. V.; Shakhov, F. M.

    2017-11-01

    A model of a thermoelectric generator is proposed, in which composite materials obtained by sintering diamond nanoparticles are used as the main component. To increase the useful conversion of heat into electric current, it is proposed to use the effect of electron drag by ballistic phonons. To reduce the ineffective heat spread, it is proposed to use the effect of thermal resistance of the boundaries between the graphite-like and diamond-like phases of the composite. An experimental confirmation of the existence of an optimal volume ratio between graphite-like and diamond-like phases of the composite is predicted and obtained. The highest achieved value of thermoelectric coefficient in the actual structure is 80 µV K-1 (which means 20 times increase compared to that of composites not of the optimal structure), with a thermal conductivity of 50 W m-1 K-1. These results were obtained with constant electrical conductivity. The combined influence of these two effects in case of the ideal composite structure should result in an increase of the thermoelectric efficiency parameter by three orders of magnitude.

  15. Breastfeeding, Infant Formula, and Introduction to Complementary Foods-Comparing Data Obtained by Questionnaires and Health Visitors' Reports to Weekly Short Message Service Text Messages.

    PubMed

    Bruun, Signe; Buhl, Susanne; Husby, Steffen; Jacobsen, Lotte Neergaard; Michaelsen, Kim F; Sørensen, Jan; Zachariassen, Gitte

    2017-11-01

    Studies on prevalence and effects of breastfeeding call for reliable and precise data collection to optimize infant nutrition, growth, and health. Data on breastfeeding and infant nutrition are at risk of, for example, recall bias or social desirability bias. The aim of the present analysis was to compare data on infant nutrition, that is, breastfeeding, use of infant formula, and introduction to complementary foods, obtained by four different methods. We assumed that weekly short message service (SMS) questions were the most reliable method, to which the other methods were compared. The study population was part of the Odense Child Cohort. The four methods used were: (a) self-administered questionnaire 3 months postpartum, (b) self-administered questionnaire 18 months postpartum, (c) registrations from health visitors visiting the families several times within the first year of life, and (d) weekly SMS questions introduced shortly after birth. In total, 639 singleton mothers with data from all four methods were included. The proportion of mothers initiating breastfeeding varied from 86% to 97%, the mean duration of exclusive breastfeeding from 12 to 19 weeks, and the mean age when introduced to complementary foods from 19 to 21 weeks. The mean duration of any breastfeeding was 33 weeks across methods. Compared with the weekly SMS questions, the self-administered questionnaires and the health visitors' reports resulted in a greater proportion of mothers with an unknown breastfeeding status, a longer duration of exclusive breastfeeding and later introduction to complementary foods, while the duration of any breastfeeding did not differ.

  16. Consideration on the Long Ecological Half-Life Component of (137)Cs in Demersal Fish Based on Field Observation Results Obtained after the Fukushima Accident.

    PubMed

    Tagami, Keiko; Uchida, Shigeo

    2016-02-16

    Radiocesium concentrations in most marine fish collected off the coast of Fukushima and surrounding prefectures have decreased with time, and four years after the Fukushima Daiichi Nuclear Power Plant accident occurred, radiocesium concentrations have generally fallen below the detectable level (ca. < 10 Bq kg(-1)-raw). Only in some demersal fish species have detectable concentration levels still been found, and even these species have showed slow radiocesium decreases. The food web was considered as the major factor causing this phenomenon; however, slow elimination rates of radiocesium from these fish species also could be the cause. The latter effect was examined by considering that the (137)Cs concentration decreasing trend in fish could be fit with a set of three exponentially decreasing components; that is, having short, intermediate, and long biological half-lives. The long ecological half-life component was calculated using a 400-1500 d period of monitoring results for Japanese rockfish (Sebastes cheni) and compared with previous reported laboratory results for biological half-life. The obtained ecological half-lives ranged from 274-365 d, and these values agreed with the biological half-life of this fish species. This result implied that the long biological half-lives of radiocesium in some demersal fish species made their radiocesium contamination periods longer.

  17. Aircraft and ground vehicle friction correlation test results obtained under winter runway conditions during joint FAA/NASA Runway Friction Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.; Vogler, William A.; Baldasare, Paul

    1988-01-01

    Aircraft and ground vehicle friction data collected during the Joint FAA/NASA Runway Friction Program under winter runway conditions are discussed and test results are summarized. The relationship between the different ground vehicle friction measurements obtained on compacted snow- and ice-covered conditions is defined together with the correlation to aircraft tire friction performance under similar runway conditions.

  18. The LANDSAT system operated in Brazil by CNPq/INPE - results obtained in the area of mapping and future perspectives

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Barbosa, M. N.

    1981-01-01

    The LANDSAT system, operated in the country by CNPg/INPE since 1973, systematically acquires, produces, and distributes both multispectral and panchromatic images obtained through remote sensing satellites to thousands of researchers and technicians involved in the natural resources survey. To cooperate in the solution of national problems, CNPq/INPE is developing efforts in the area of manipulation of those images with the objective of making them useful as planimetric bases for the simple revision of already published maps or for its utilization as basic material in regions not yet reliability mapped. The results obtained from performed tests are presented and the existing limitations are discussed. The new system purchased to handle data from the next series of LANDSAT as well as from MAPSAT and SPOT which will be in operation within the 80's decade, and are designed not only for natural resources survey but also for the solution of cartographic problems.

  19. Carbon nanofibers obtained from electrospinning process

    NASA Astrophysics Data System (ADS)

    Bovi de Oliveira, Juliana; Müller Guerrini, Lília; Sizuka Oishi, Silvia; Rogerio de Oliveira Hein, Luis; dos Santos Conejo, Luíza; Cerqueira Rezende, Mirabel; Cocchieri Botelho, Edson

    2018-02-01

    In recent years, reinforcements consisting of carbon nanostructures, such as carbon nanotubes, fullerenes, graphenes, and carbon nanofibers have received significant attention due mainly to their chemical inertness and good mechanical, electrical and thermal properties. Since carbon nanofibers comprise a continuous reinforcing with high specific surface area, associated with the fact that they can be obtained at a low cost and in a large amount, they have shown to be advantageous compared to traditional carbon nanotubes. The main objective of this work is the processing of carbon nanofibers, using polyacrylonitrile (PAN) as a precursor, obtained by the electrospinning process via polymer solution, with subsequent use for airspace applications as reinforcement in polymer composites. In this work, firstly PAN nanofibers were produced by electrospinning with diameters in the range of (375 ± 85) nm, using a dimethylformamide solution. Using a furnace, the PAN nanofiber was converted into carbon nanofiber. Morphologies and structures of PAN and carbon nanofibers were investigated by scanning electron microscopy, Raman Spectroscopy, thermogravimetric analyses and differential scanning calorimeter. The resulting residual weight after carbonization was approximately 38% in weight, with a diameters reduction of 50%, and the same showed a carbon yield of 25%. From the analysis of the crystalline structure of the carbonized material, it was found that the material presented a disordered structure.

  20. Comparison of orbital volume obtained by tomography and rapid prototyping.

    PubMed

    Roça, Guilherme Berto; Foggiatto, José Aguiomar; Ono, Maria Cecilia Closs; Ono, Sergio Eiji; da Silva Freitas, Renato

    2013-11-01

    This study aims to compare orbital volume obtained by helical tomography and rapid prototyping. The study sample was composed of 6 helical tomography scans. Eleven healthy orbits were identified to have their volumes measured. The volumetric analysis with the helical tomography utilized the same protocol developed by the Plastic Surgery Unit of the Federal University of Paraná. From the CT images, 11 prototypes were created, and their respective volumes were analyzed in 2 ways: using software by SolidWorks and by direct analysis, when the prototype was filled with saline solution. For statistical analysis, the results of the volumes of the 11 orbits were considered independent. The average orbital volume measurements obtained by the method of Ono et al was 20.51 cm, the average obtained by the SolidWorks program was 20.64 cm, and the average measured using the prototype method was 21.81 cm. The 3 methods demonstrated a strong correlation between the measurements. The right and left orbits of each patient had similar volumes. The tomographic method for the analysis of orbital volume using the Ono protocol yielded consistent values, and by combining this method with rapid prototyping, both reliability validations of results were enhanced.

  1. An affordable method to obtain cultured endothelial cells from peripheral blood

    PubMed Central

    Bueno-Betí, Carlos; Novella, Susana; Lázaro-Franco, Macarena; Pérez-Cremades, Daniel; Heras, Magda; Sanchís, Juan; Hermenegildo, Carlos

    2013-01-01

    The culture of endothelial progenitor cells (EPC) provides an excellent tool to research on EPC biology and vascular regeneration and vasculogenesis. The use of different protocols to obtain EPC cultures makes it difficult to obtain comparable results in different groups. This work offers a systematic comparison of the main variables of most commonly used protocols for EPC isolation, culture and functional evaluation. Peripheral blood samples from healthy individuals were recovered and mononuclear cells were cultured. Different recovery and culture conditions were tested: blood volume, blood anticoagulant, coating matrix and percentage of foetal bovine serum (FBS) in culture media. The success of culture procedure, first colonies of endothelial cells appearance time, correlation with number of circulating EPC (cEPC) and functional comparison with human umbilical vein endothelial cells (HUVEC) were studied. The use of heparin, a minimum blood volume of 30 ml, fibronectin as a coating matrix and endothelial growing media-2 supplemented with 20% FBS increased the success of obtaining EPC cultures up to 80% of the processed samples while reducing EPC colony appearance mean time to a minimum of 13 days. Blood samples exhibiting higher cEPC numbers resulted in reduced EPC colony appearance mean time. Cells isolated by using this combination were endothelial cell-like EPCs morphological and phenotypically. Functionally, cultured EPC showed decreased growing and vasculogenic capacity when compared to HUVEC. Thus, above-mentioned conditions allow the isolation and culture of EPC with smaller blood volumes and shorter times than currently used protocols. PMID:24118735

  2. Obtaining high resolution XUV coronal images

    NASA Technical Reports Server (NTRS)

    Golub, L.; Spiller, E.

    1992-01-01

    Photographs obtained during three flights of an 11 inch diameter normal incident soft X-ray (wavelength 63.5 A) telescope are analyzed and the data are compared to the results expected from tests of the mirror surfaces. Multilayer coated X ray telescopes have the potential for 0.01 arcsec resolution, and there is optimism that such high quality mirrors can be built. Some of the factors which enter into the performance actually achieved in practice are as follows: quality of the mirror substrate, quality of the multilayer coating, and number of photons collected. Measurements of multilayer mirrors show that the actual performance achieved in the solar X-ray images demonstrates a reduction in the scattering compared to that calculated from the topography of the top surface of the multilayer. In the brief duration of a rocket flight, the resolution is also limited by counting statistics from the number of photons collected. At X-ray Ultraviolet (XUV) wavelengths from 171 to 335 A the photon flux should be greater than 10(exp 10) ph/sec, so that a resolution better than 0.1 arcsec might be achieved, if mirror quality does not provide a limit first. In a satellite, a large collecting area will be needed for the highest resolution.

  3. Results of in vivo measurements of strontium-90 body-burden in Urals residents: analyses of data obtained 2006-2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolstykh, E. I.; Bougrov, N. G.; Krivoshchapov, Victor A.

    2012-06-01

    A part of the Urals territory was contaminated with 90Sr and 137Cs in the 1950s as a result of accidents at the "Mayak" Production Association. The paper describes the analysis of in vivo 90Sr measurements in Urals residents. The measurements were performed with the use of whole-body-counter SICH-9.1M in 2006-2012. Totally 5840 measurements for 4876 persons were performed from 2006 to 2012; maximal measured value was 24 kBq. Earlier, similar measurements were performed with SICH-9.1 (1974-1997). Comparison of the results obtained with SICH-9.1 and SICH-9.1M has shown a good agreement of the two data sets.

  4. Gravity Changes and Internal Processes: Some Results Obtained from Observations at Three Volcanoes

    NASA Astrophysics Data System (ADS)

    Jentzsch, Gerhard; Weise, Adelheid; Rey, Carlos; Gerstenecker, Carl

    Temporal gravity changes provide information about mass and/or density variations within and below the volcano edifice. Three active volcanoes have been under investigation; each of them related to a plate boundary: Mayon/Luzon/Philippines, Merapi/Java/Indonesia, and Galeras/Colombia. The observed gravity changes are smaller than previously expected but significant. For the three volcanoes under investigation, and within the observation period, mainly the increase of gravity is observed, ranging from 1,000 nm-2 to 1,600 nms-2. Unexpectedly, the gravity increase is confined to a rather small area with radii of 5 to 8 km around the summit. At Mayon and Merapi the parallel GPS measurements yield no significant elevation changes. This is crucial for the interpretation, as the internal pressure variations do not lead to significant deformation at the surface. Thus the classical Mogi-model for a shallow extending magma reservoir cannot apply. To confine the possible models, the attraction due to changes of groundwater level or soil moisture is estimated along the slope of Merapi exemplarily by 2-D modelling. Mass redistribution or density changes were evaluated within the vent as well as deeper fluid processes to explain the gravity variations; the results are compared to the model incorporating the additional effect of elastic deformation.

  5. Mercury's plasma belt: hybrid simulations results compared to in-situ measurements

    NASA Astrophysics Data System (ADS)

    Hercik, D.; Travnicek, P. M.; Schriver, D.; Hellinger, P.

    2012-12-01

    The presence of plasma belt and trapped particles region in the Mercury's inner magnetosphere has been questionable due to small dimensions of the magnetosphere of Mercury compared to Earth, where these regions are formed. Numerical simulations of the solar wind interaction with Mercury's magnetic field suggested that such a structure could be found also in the vicinity of Mercury. These results has been recently confirmed also by MESSENGER observations. Here we present more detailed analysis of the plasma belt structure and quasi-trapped particle population characteristics and behaviour under different orientations of the interplanetary magnetic field.The plasma belt region is constantly supplied with solar wind protons via magnetospheric flanks and tail current sheet region. Protons inside the plasma belt region are quasi-trapped in the magnetic field of Mercury and perform westward drift along the planet. This region is well separated by a magnetic shell and has higher average temperatures and lower bulk proton current densities than surrounding area. On the day side the population exhibits loss cone distribution function matching the theoretical loss cone angle. Simulations results are also compared to in-situ measurements acquired by MESSENGER MAG and FIPS instruments.

  6. XCluSim: a visual analytics tool for interactively comparing multiple clustering results of bioinformatics data

    PubMed Central

    2015-01-01

    Background Though cluster analysis has become a routine analytic task for bioinformatics research, it is still arduous for researchers to assess the quality of a clustering result. To select the best clustering method and its parameters for a dataset, researchers have to run multiple clustering algorithms and compare them. However, such a comparison task with multiple clustering results is cognitively demanding and laborious. Results In this paper, we present XCluSim, a visual analytics tool that enables users to interactively compare multiple clustering results based on the Visual Information Seeking Mantra. We build a taxonomy for categorizing existing techniques of clustering results visualization in terms of the Gestalt principles of grouping. Using the taxonomy, we choose the most appropriate interactive visualizations for presenting individual clustering results from different types of clustering algorithms. The efficacy of XCluSim is shown through case studies with a bioinformatician. Conclusions Compared to other relevant tools, XCluSim enables users to compare multiple clustering results in a more scalable manner. Moreover, XCluSim supports diverse clustering algorithms and dedicated visualizations and interactions for different types of clustering results, allowing more effective exploration of details on demand. Through case studies with a bioinformatics researcher, we received positive feedback on the functionalities of XCluSim, including its ability to help identify stably clustered items across multiple clustering results. PMID:26328893

  7. Some Results on Sea Ice Rheology for the Seasonal Ice Zone, Obtained from the Deformation Field of Sea Ice Drift Pattern

    NASA Astrophysics Data System (ADS)

    Toyota, T.; Kimura, N.

    2017-12-01

    Sea ice rheology which relates sea ice stress to the large-scale deformation of the ice cover has been a big issue to numerical sea ice modelling. At present the treatment of internal stress within sea ice area is based mostly on the rheology formulated by Hibler (1979), where the whole sea ice area behaves like an isotropic and plastic matter under the ordinary stress with the yield curve given by an ellipse with an aspect ratio (e) of 2, irrespective of sea ice area and horizontal resolution of the model. However, this formulation was initially developed to reproduce the seasonal variation of the perennial ice in the Arctic Ocean. As for its applicability to the seasonal ice zones (SIZ), where various types of sea ice are present, it still needs validation from observational data. In this study, the validity of this rheology was examined for the Sea of Okhotsk ice, typical of the SIZ, based on the AMSR-derived ice drift pattern in comparison with the result obtained for the Beaufort Sea. To examine the dependence on a horizontal scale, the coastal radar data operated near the Hokkaido coast, Japan, were also used. Ice drift pattern was obtained by a maximum cross-correlation method with grid spacings of 37.5 km from the 89 GHz brightness temperature of AMSR-E for the entire Sea of Okhotsk and the Beaufort Sea and 1.3 km from the coastal radar for the near-shore Sea of Okhotsk. The validity of this rheology was investigated from a standpoint of work rate done by deformation field, following the theory of Rothrock (1975). In analysis, the relative rates of convergence were compared between theory and observation to check the shape of yield curve, and the strain ellipse at each grid cell was estimated to see the horizontal variation of deformation field. The result shows that the ellipse of e=1.7-2.0 as the yield curve represents the observed relative conversion rates well for all the ice areas. Since this result corresponds with the yield criterion by Tresca and

  8. Comparative Paleomagnetic Study of the Quaternary-Pliocene Sedimentation Rates in the Arctic Basin: First Results

    NASA Astrophysics Data System (ADS)

    Elkina, D.; Piskarev, A.

    2017-12-01

    Accurate dating of marine sediments from the Arctic Basin continues to remain a subject of great debates over the last decades. Due to the lack of adequate materials for biostratigraphy, and isotope analyses, paleomagnetic reconstructions came on line here but still yielded ambivalent interpretations. Moreover, sedimentation rates, estimated for isolated morphological features in the Arctic Ocean, are often extended to the whole Basin and, therefore, lead to significant approximations of the sedimentation pattern distribution. Paleomagnetic study of two sediment cores up to 8 meter long, collected at the Mendeleev Rise, and the Lomonosov Ridge, have provided the opportunity to compare sedimentation regimes on these two profound structures of the Arctic Basin. Cores PS72/396 and PS87/023 were carried out along the cruises of RV Polarstern at the Mendeleev Rise (Stein et. al, 2010), and the Lomonosov Ridge (Stein, 2015) respectively. Measurements of natural remanent magnetization (NRM) and anhysteretic remanence (ARM) acquisition with the following alternating field (AF) demagnetization were performed on u-channel samples, obtained from the cores, at the Center for Geo-Environmental Research and Modeling (GEOMODEL) of the Research Park, St. Petersburg State University. According to preliminary results, core PS72/396 has shown a change from positive to negative inclinations at ca. 120 cm below sea floor (cmbsf), prevailed up to ca. 360 cmbsf where it gets back to the positive ones. This trend is comparable with some previous paleomagnetic results, conducted on cores from the Mendeleev Rise (Piskarev et al., 2013; Elkina, 2014). In contrast, for core PS87/023, a relevant drop to negative inclinations can be observed only after 330 cmbsf. That could signify a dramatic difference in sedimentation rates between the sites during the Quaternary and Pliocene. Nevertheless, a rather complicated picture of the AF data assumes effects of secondary overprints, having influenced

  9. TEPC measurements obtained on the Mir space station.

    PubMed

    Bottollier-Depois, J F; Siegrist, M; Petrov, V M; Shurshakov, V V; Bengin, V; Koslova, S B

    2002-10-01

    Measurements of the radiation environment inside the Mir space station were performed with a tissue equivalent proportional counter (TEPC) during the Antares mission in 1992, and over a long period following it. Interesting results concerning radiation measurements show (a) the South Atlantic Anomaly crossing, (b) the increase of radiation near the poles, and (c) the effects of solar particle events (the most important one occurring in early November 1992). This data also provides information about the dose and the quality factor of the radiation to which the cosmonauts were exposed during different missions. These data are compared with measurements obtained using a solid state detector. c2002 Elsevier Science Ltd. All rights reserved.

  10. The Radial Distribution Function (RDF) of Amorphous Selenium Obtained through the Vacuum Evaporator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guda, Bardhyl; Dede, Marie

    2010-01-21

    After the amorphous selenium obtained through the vacuum evaporator, the relevant diffraction intensity is taken and its processing is made. Further on the interferential function is calculated and the radial density function is defined. For determining these functions are used two methods, which were compared with each other and finally are received results for amorphous selenium RDF.

  11. Prospective study comparing laparoscopic and open adenomectomy: Surgical and functional results.

    PubMed

    Garcia-Segui, A; Angulo, J C

    Open adenomectomy (OA) is the surgery of choice for large volume benign prostatic hyperplasia, and laparoscopic adenomectomy (LA) represents a minimally invasive alternative. We present a long-term, prospective study comparing both techniques. The study consecutively included 199 patients with benign prostatic hyperplasia and prostate volumes>80g who were followed for more than 12 months. The patients underwent OA (n=97) or LA (n=102). We recorded and compared demographic and perioperative data, functional results and complications using a descriptive statistical analysis. The mean age was 69.2±7.7 years (range 42-87), and the mean prostate volume (measured by TRUS) was 112.1±32.7mL (range 78-260). There were no baseline differences among the groups in terms of age, ASA scale, prostate volume, PSA levels, Qmax, IPSS, QoL or treatments prior to the surgery. The surgical time (P<.0001) and catheter time (P<.0002) were longer in the LA group. Operative bleeding (P<.0001), transfusion rate (P=.0015) and mean stay (P<.0001) were significantly lower in the LA group. The LA group had a lower rate of complications (P=.04), but there were no significant differences between the groups in terms of major complications (Clavien score≥3) (P=.13) or in the rate of late complications (at one year) (P=.66). There were also no differences between the groups in the functional postoperative results: IPSS (P=.17), QoL (P=.3) and Qmax (P=.17). LA is a reasonable, safe and effective alternative that results in less bleeding, fewer transfusions, shorter hospital stays and lower morbidity than OA. LA has similar functional results to OA, at the expense of longer surgical times and longer catheter times. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Four methods of attitude determination for spin-stabilized spacecraft with applications and comparative results

    NASA Technical Reports Server (NTRS)

    Smith, G. A.

    1975-01-01

    The attitude of a spacecraft is determined by specifying independent parameters which relate the spacecraft axes to an inertial coordinate system. Sensors which measure angles between spin axis and other vectors directed to objects or fields external to the spacecraft are discussed. For the spin-stabilized spacecraft considered, the spin axis is constant over at least an orbit, but separate solutions based on sensor angle measurements are different due to propagation of errors. Sensor-angle solution methods are described which minimize the propagated errors by making use of least squares techniques over many sensor angle measurements and by solving explicitly (in closed form) for the spin axis coordinates. These methods are compared with star observation solutions to determine if satisfactory accuracy is obtained by each method.

  13. [Comparability study of analytical results between a group of clinical laboratories].

    PubMed

    Alsius-Serra, A; Ballbé-Anglada, M; López-Yeste, M L; Buxeda-Figuerola, M; Guillén-Campuzano, E; Juan-Pereira, L; Colomé-Mallolas, C; Caballé-Martín, I

    2015-01-01

    To describe the study of the comparability of the measurements levels of biological tests processed in biochemistry in Catlab's 4 laboratories. Quality requirements, coefficients of variation and total error (CV% and TE %) were established. Controls were verified with the precision requirements (CV%) in each test and each individual laboratory analyser. Fresh serum samples were used for the comparability study. The differences were analysed using a Microsoft Access® application that produces modified Bland-Altman plots. The comparison of 32 biological parameters that are performed in more than one laboratory and/or analyser generated 306 Bland-Altman graphs. Of these, 101 (33.1%) fell within the accepted range of values based on biological variability, and 205 (66.9%) required revision. Data were re-analysed based on consensus minimum specifications for analytical quality (consensus of the Asociación Española de Farmacéuticos Analistas (AEFA), the Sociedad Española de Bioquímica Clínica y Patología Molecular (SEQC), the Asociación Española de Biopatología Médica (AEBM) and the Sociedad Española de Hematología y Hemoterapia (SEHH), October 2013). With the new specifications, 170 comparisons (56%) fitted the requirements and 136 (44%) required additional review. Taking into account the number of points that exceeded the requirement, random errors, range of results in which discrepancies were detected, and range of clinical decision, it was shown that the 44% that required review were acceptable, and the 32 tests were comparable in all laboratories and analysers. The analysis of the results showed that the consensus requirements of the 4 scientific societies were met. However, each laboratory should aim to meet stricter criteria for total error. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  14. KRAS mutation testing in colorectal cancer: comparison of the results obtained using 3 different methods for the analysis of codons G12 and G13.

    PubMed

    Bihl, Michel P; Hoeller, Sylvia; Andreozzi, Maria Carla; Foerster, Anja; Rufle, Alexander; Tornillo, Luigi; Terracciano, Luigi

    2012-03-01

    Targeting the epidermal growth factor receptor (EGFR) is a new therapeutic option for patients with metastatic colorectal or lung carcinoma. However, the therapy efficiency highly depends on the KRAS mutation status in the given tumour. Therefore a reliable and secure KRAS mutation testing is crucial. Here we investigated 100 colorectal carcinoma samples with known KRAS mutation status (62 mutated cases and 38 wild type cases) in a comparative manner with three different KRAS mutation testing techniques (Pyrosequencing, Dideoxysequencing and INFINITI) in order to test their reliability and sensitivity. For the large majority of samples (96/100, 96%), the KRAS mutation status obtained by all three methods was the same. Only two cases with clear discrepancies were observed. One case was reported as wild type by the INFINITI method while the two other methods detected a G13C mutation. In the second case the mutation could be detected by the Pyrosequencing and INFINITI method (15% and 15%), while no signal for mutation could be observed with the Dideoxysequencing method. Additional two unclear results were due to a detection of a G12V with the INFINITI method, which was below cut-off when repeated and which was not detectable by the other two methods and very weak signals in a G12V mutated case with the Dideoxy- and Pyroseqencing method compared to the INFINITI method, respectively. In summary all three methods are reliable and robust methods in detecting KRAS mutations. INFINITI, however seems to be slightly more sensitive compared to Dideoxy- and Pyrosequencing.

  15. Porous titanium obtained by a new powder metallurgy technique: Preliminary results of human osteoblast adhesion on surface polished substrates.

    PubMed

    Biasotto, M; Ricceri, R; Scuor, N; Schmid, C; Sandrucci, M A; Di Lenarda, R; Matteazzi, P

    2003-01-01

    This study concerns a novel powder metallurgy method for producing porous titanium (pTi) exhibiting high mechanical properties. The preparation procedure consisted of the following stages: first, the preparation of Ti and titanium hydride (TiH2) powder mixtures and their consolidation with a cold isostatic press, followed by a sintering of the green bodies performed with hot isostatic press (HIP) equipment. Thermal decomposition in controlled environment of the TiH2 phase results in the foam structure. The resulting porosity percolates with a volume fraction of approximately 20%. The final material exhibits interesting mechanical properties, comparable to those of full density titanium (between grade 2 and grade 3), with the advantage of a minor density. The samples produced were tested to verify their biological response by studying the effectiveness of osteoblast adhesion and growth. In this preliminary study, osteoblastic cell morphology was investigated and compared to that observed on fully dense commercially pure titanium (Ti-cp) (ASTM, grade 3). The preliminary results were promising regarding cellular adhesion and spreading. (Journal of Applied Biomaterials & Biomechanics 2003; 1: 172-7).

  16. Breast volume assessment: comparing five different techniques.

    PubMed

    Bulstrode, N; Bellamy, E; Shrotria, S

    2001-04-01

    Breast volume assessment is not routinely performed pre-operatively because as yet there is no accepted technique. There have been a variety of methods published, but this is the first study to compare these techniques. We compared volume measurements obtained from mammograms (previously compared to mastectomy specimens) with estimates of volume obtained from four other techniques: thermoplastic moulding, magnetic resonance imaging, Archimedes principle and anatomical measurements. We also assessed the acceptability of each method to the patient. Measurements were performed on 10 women, which produced results for 20 breasts. We were able to calculate regression lines between volume measurements obtained from mammography to the other four methods: (1) magnetic resonance imaging (MRI), 379+(0.75 MRI) [r=0.48], (2) Thermoplastic moulding, 132+(1.46 Thermoplastic moulding) [r=0.82], (3) Anatomical measurements, 168+(1.55 Anatomical measurements) [r=0.83]. (4) Archimedes principle, 359+(0.6 Archimedes principle) [r=0.61] all units in cc. The regression curves for the different techniques are variable and it is difficult to reliably compare results. A standard method of volume measurement should be used when comparing volumes before and after intervention or between individual patients, and it is unreliable to compare volume measurements using different methods. Calculating the breast volume from mammography has previously been compared to mastectomy samples and shown to be reasonably accurate. However we feel thermoplastic moulding shows promise and should be further investigated as it gives not only a volume assessment but a three-dimensional impression of the breast shape, which may be valuable in assessing cosmesis following breast-conserving-surgery.

  17. Comparative studies on single-layer reduced graphene oxide films obtained by electrochemical reduction and hydrazine vapor reduction

    NASA Astrophysics Data System (ADS)

    Wang, Zhijuan; Wu, Shixin; Zhang, Juan; Chen, Peng; Yang, Guocheng; Zhou, Xiaozhu; Zhang, Qichun; Yan, Qingyu; Zhang, Hua

    2012-02-01

    The comparison between two kinds of single-layer reduced graphene oxide (rGO) sheets, obtained by reduction of graphene oxide (GO) with the electrochemical method and hydrazine vapor reduction, referred to as E-rGO and C-rGO, respectively, is systematically studied. Although there is no morphology difference between the E-rGO and C-rGO films adsorbed on solid substrates observed by AFM, the reduction process to obtain the E-rGO and C-rGO films is quite different. In the hydrazine vapor reduction, the nitrogen element is incorporated into the obtained C-rGO film, while no additional element is introduced to the E-rGO film during the electrochemical reduction. Moreover, Raman spectra show that the electrochemical method is more effective than the hydrazine vapor reduction method to reduce the GO films. In addition, E-rGO shows better electrocatalysis towards dopamine than does C-rGO. This study is helpful for researchers to understand these two different reduction methods and choose a suitable one to reduce GO based on their experimental requirements.

  18. Analysis of genomic alterations in neuroblastoma by multiplex ligation-dependent probe amplification and array comparative genomic hybridization: a comparison of results.

    PubMed

    Combaret, Valérie; Iacono, Isabelle; Bréjon, Stéphanie; Schleiermacher, Gudrun; Pierron, Gäelle; Couturier, Jérôme; Bergeron, Christophe; Blay, Jean-Yves

    2012-12-01

    In cases of neuroblastoma, recurring genetic alterations--losses of the 1p, 3p, 4p, and 11q and/or gains of 1q, 2p, and 17q chromosome arms--are currently used to define the therapeutic strategy in therapeutic protocols for low- and intermediate-risk patients. Different genome-wide analysis techniques, such as array comparative genomic hybridization (aCGH) or multiplex ligation-dependent probe amplification (MLPA), have been suggested for detecting chromosome segmental abnormalities. In this study, we compared the results of the two technologies in the analyses of the DNA of tumor samples from 91 neuroblastoma patients. Similar results were obtained with the two techniques for 75 samples (82%). In five cases (5.5%), the MLPA results were not interpretable. Discrepancies between the aCGH and MLPA results were observed in 11 cases (12%). Among the discrepancies, a 18q21.2-qter gain and 16p11.2 and 11q14.1-q14.3 losses were detected only by aCGH. The MLPA results showed that the 7p, 7q, and 14q chromosome arms were affected in six cases, while in two cases, 2p and 17q gains were observed; these results were confirmed by neither aCGH nor fluorescence in situ hybridization (FISH) analysis. Because of the higher sensitivity and specificity of genome-wide information, reasonable cost, and shorter time of aCGH analysis, we recommend the aCGH procedure for the analysis of genomic alterations in neuroblastoma. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Incident CTS in a large pooled cohort study: associations obtained by a Job Exposure Matrix versus associations obtained from observed exposures.

    PubMed

    Dale, Ann Marie; Ekenga, Christine C; Buckner-Petty, Skye; Merlino, Linda; Thiese, Matthew S; Bao, Stephen; Meyers, Alysha Rose; Harris-Adamson, Carisa; Kapellusch, Jay; Eisen, Ellen A; Gerr, Fred; Hegmann, Kurt T; Silverstein, Barbara; Garg, Arun; Rempel, David; Zeringue, Angelique; Evanoff, Bradley A

    2018-03-29

    There is growing use of a job exposure matrix (JEM) to provide exposure estimates in studies of work-related musculoskeletal disorders; few studies have examined the validity of such estimates, nor did compare associations obtained with a JEM with those obtained using other exposures. This study estimated upper extremity exposures using a JEM derived from a publicly available data set (Occupational Network, O*NET), and compared exposure-disease associations for incident carpal tunnel syndrome (CTS) with those obtained using observed physical exposure measures in a large prospective study. 2393 workers from several industries were followed for up to 2.8 years (5.5 person-years). Standard Occupational Classification (SOC) codes were assigned to the job at enrolment. SOC codes linked to physical exposures for forceful hand exertion and repetitive activities were extracted from O*NET. We used multivariable Cox proportional hazards regression models to describe exposure-disease associations for incident CTS for individually observed physical exposures and JEM exposures from O*NET. Both exposure methods found associations between incident CTS and exposures of force and repetition, with evidence of dose-response. Observed associations were similar across the two methods, with somewhat wider CIs for HRs calculated using the JEM method. Exposures estimated using a JEM provided similar exposure-disease associations for CTS when compared with associations obtained using the 'gold standard' method of individual observation. While JEMs have a number of limitations, in some studies they can provide useful exposure estimates in the absence of individual-level observed exposures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Quantitative Comparison of Tandem Mass Spectra Obtained on Various Instruments

    NASA Astrophysics Data System (ADS)

    Bazsó, Fanni Laura; Ozohanics, Oliver; Schlosser, Gitta; Ludányi, Krisztina; Vékey, Károly; Drahos, László

    2016-08-01

    The similarity between two tandem mass spectra, which were measured on different instruments, was compared quantitatively using the similarity index (SI), defined as the dot product of the square root of peak intensities in the respective spectra. This function was found to be useful for comparing energy-dependent tandem mass spectra obtained on various instruments. Spectral comparisons show the similarity index in a 2D "heat map", indicating which collision energy combinations result in similar spectra, and how good this agreement is. The results and methodology can be used in the pharma industry to design experiments and equipment well suited for good reproducibility. We suggest that to get good long-term reproducibility, it is best to adjust the collision energy to yield a spectrum very similar to a reference spectrum. It is likely to yield better results than using the same tuning file, which, for example, does not take into account that contamination of the ion source due to extended use may influence instrument tuning. The methodology may be used to characterize energy dependence on various instrument types, to optimize instrumentation, and to study the influence or correlation between various experimental parameters.

  1. Comparing Two Examination Results Using Means of Sample Means and Control Charts

    ERIC Educational Resources Information Center

    Alabi-Labaika, A. Bisi; Ahani, E.

    2015-01-01

    Some examination candidates submit their scripts first, sometimes, for recognition as being brilliant, and some do for not knowing what to write. However, some equally submit last because they want to dot i's and cross t's. The objective of this research is to compare the results of both the earliest and latest submissions with the aim of finding…

  2. Improved Correction of Atmospheric Pressure Data Obtained by Smartphones through Machine Learning

    PubMed Central

    Kim, Yong-Hyuk; Ha, Ji-Hun; Kim, Na-Young; Im, Hyo-Hyuc; Sim, Sangjin; Choi, Reno K. Y.

    2016-01-01

    A correction method using machine learning aims to improve the conventional linear regression (LR) based method for correction of atmospheric pressure data obtained by smartphones. The method proposed in this study conducts clustering and regression analysis with time domain classification. Data obtained in Gyeonggi-do, one of the most populous provinces in South Korea surrounding Seoul with the size of 10,000 km2, from July 2014 through December 2014, using smartphones were classified with respect to time of day (daytime or nighttime) as well as day of the week (weekday or weekend) and the user's mobility, prior to the expectation-maximization (EM) clustering. Subsequently, the results were analyzed for comparison by applying machine learning methods such as multilayer perceptron (MLP) and support vector regression (SVR). The results showed a mean absolute error (MAE) 26% lower on average when regression analysis was performed through EM clustering compared to that obtained without EM clustering. For machine learning methods, the MAE for SVR was around 31% lower for LR and about 19% lower for MLP. It is concluded that pressure data from smartphones are as good as the ones from national automatic weather station (AWS) network. PMID:27524999

  3. A new warfarin dosing algorithm including VKORC1 3730 G > A polymorphism: comparison with results obtained by other published algorithms.

    PubMed

    Cini, Michela; Legnani, Cristina; Cosmi, Benilde; Guazzaloca, Giuliana; Valdrè, Lelia; Frascaro, Mirella; Palareti, Gualtiero

    2012-08-01

    Warfarin dosing is affected by clinical and genetic variants, but the contribution of the genotype associated with warfarin resistance in pharmacogenetic algorithms has not been well assessed yet. We developed a new dosing algorithm including polymorphisms associated both with warfarin sensitivity and resistance in the Italian population, and its performance was compared with those of eight previously published algorithms. Clinical and genetic data (CYP2C9*2, CYP2C9*3, VKORC1 -1639 G > A, and VKORC1 3730 G > A) were used to elaborate the new algorithm. Derivation and validation groups comprised 55 (58.2% men, mean age 69 years) and 40 (57.5% men, mean age 70 years) patients, respectively, who were on stable anticoagulation therapy for at least 3 months with different oral anticoagulation therapy (OAT) indications. Performance of the new algorithm, evaluated with mean absolute error (MAE) defined as the absolute value of the difference between observed daily maintenance dose and predicted daily dose, correlation with the observed dose and R(2) value, was comparable with or slightly lower than that obtained using the other algorithms. The new algorithm could correctly assign 53.3%, 50.0%, and 57.1% of patients to the low (≤25 mg/week), intermediate (26-44 mg/week) and high (≥ 45 mg/week) dosing range, respectively. Our data showed a significant increase in predictive accuracy among patients requiring high warfarin dose compared with the other algorithms (ranging from 0% to 28.6%). The algorithm including VKORC1 3730 G > A, associated with warfarin resistance, allowed a more accurate identification of resistant patients who require higher warfarin dosage.

  4. Probabilistic techniques for obtaining accurate patient counts in Clinical Data Warehouses

    PubMed Central

    Myers, Risa B.; Herskovic, Jorge R.

    2011-01-01

    Proposal and execution of clinical trials, computation of quality measures and discovery of correlation between medical phenomena are all applications where an accurate count of patients is needed. However, existing sources of this type of patient information, including Clinical Data Warehouses (CDW) may be incomplete or inaccurate. This research explores applying probabilistic techniques, supported by the MayBMS probabilistic database, to obtain accurate patient counts from a clinical data warehouse containing synthetic patient data. We present a synthetic clinical data warehouse (CDW), and populate it with simulated data using a custom patient data generation engine. We then implement, evaluate and compare different techniques for obtaining patients counts. We model billing as a test for the presence of a condition. We compute billing’s sensitivity and specificity both by conducting a “Simulated Expert Review” where a representative sample of records are reviewed and labeled by experts, and by obtaining the ground truth for every record. We compute the posterior probability of a patient having a condition through a “Bayesian Chain”, using Bayes’ Theorem to calculate the probability of a patient having a condition after each visit. The second method is a “one-shot” approach that computes the probability of a patient having a condition based on whether the patient is ever billed for the condition Our results demonstrate the utility of probabilistic approaches, which improve on the accuracy of raw counts. In particular, the simulated review paired with a single application of Bayes’ Theorem produces the best results, with an average error rate of 2.1% compared to 43.7% for the straightforward billing counts. Overall, this research demonstrates that Bayesian probabilistic approaches improve patient counts on simulated patient populations. We believe that total patient counts based on billing data are one of the many possible applications of our

  5. Comparative studies on adsorptive removal of heavy metal ions by biosorbent, bio-char and activated carbon obtained from low cost agro-residue.

    PubMed

    Kırbıyık, Çisem; Pütün, Ayşe Eren; Pütün, Ersan

    2016-01-01

    In this study, Fe(III) and Cr(III) metal ion adsorption processes were carried out with three adsorbents in batch experiments and their adsorption performance was compared. These adsorbents were sesame stalk without pretreatment, bio-char derived from thermal decomposition of biomass, and activated carbon which was obtained from chemical activation of biomass. Scanning electron microscopy and Fourier transform-infrared techniques were used for characterization of adsorbents. The optimum conditions for the adsorption process were obtained by observing the influences of solution pH, adsorbent dosage, initial solution concentration, contact time and temperature. The optimum adsorption efficiencies were determined at pH 2.8 and pH 4.0 for Fe(III) and Cr(III) metal ion solutions, respectively. The experimental data were modelled by different isotherm models and the equilibriums were well described by the Langmuir adsorption isotherm model. The pseudo-first-order, pseudo-second-order kinetic, intra-particle diffusion and Elovich models were applied to analyze the kinetic data and to evaluate rate constants. The pseudo-second-order kinetic model gave a better fit than the others. The thermodynamic parameters, such as Gibbs free energy change ΔG°, standard enthalpy change ΔH° and standard entropy change ΔS° were evaluated. The thermodynamic study showed the adsorption was a spontaneous endothermic process.

  6. A method to obtain static potential for electron-molecule scattering

    NASA Astrophysics Data System (ADS)

    Srivastava, Rajesh; Das, Tapasi; Stauffer, Allan

    2014-05-01

    Electron scattering from molecules is complicated by the fact that molecules are a multi-centered target with the nuclei of the constituent atoms being a center of charge. One of the most important parts of a scattering calculation is to obtain the static potential which represents the interaction of the incident electron with the unperturbed charge distribution of the molecule. A common way to represent the charge distribution of molecules is with Gaussian orbitals centered on the various nuclei. We have derived a way to calculate spherically-averaged molecular static potentials using this form of molecular wave function which is mostly analytic. This method has been applied to elastic electron scattering from water molecules and we obtained differential cross sections which are compared with previous experimental and theoretical results. The method can be extended to more complex molecules. One of us (RS) is thankful to IAEA, Vienna, Austria and DAE-BRNS, Mumbai, India for financial support.

  7. A novel comparator featured with input data characteristic

    NASA Astrophysics Data System (ADS)

    Jiang, Xiaobo; Ye, Desheng; Xu, Xiangmin; Zheng, Shuai

    2016-03-01

    Two types of low-power asynchronous comparators featured with input data statistical characteristic are proposed in this article. The asynchronous ripple comparator stops comparing at the first unequal bit but delivers the result to the least significant bit. The pre-stop asynchronous comparator can completely stop comparing and obtain results immediately. The proposed and contrastive comparators were implemented in SMIC 0.18 μm process with different bit widths. Simulation shows that the proposed pre-stop asynchronous comparator features the lowest power consumption, shortest average propagation delay and highest area efficiency among the comparators. Data path of low-density parity check decoder using the proposed pre-stop asynchronous comparators are most power efficient compared with other data paths with synthesised, clock gating and bitwise competition logic comparators.

  8. A Comparative Analysis of Master Casts Obtained using Different Surface Treatments on Impression Copings for Single Tooth Implant Replacement -An In vitro Study.

    PubMed

    Abrol, Surbhi; Nagpal, Archana; Kaur, Rupandeep; Verma, Ramit; Katna, Vishal; Gupt, Parikshit

    2017-08-01

    Minor rotation of impression coping secured in the impression is an avoidable error that needs to be minimized to ensure precise positioning of implant analog in master cast. The aim of the study was to compare the precision in obtaining master casts by improving the stability of impression copings in the impression with the use of tray adhesive along various surface treatments to increase surface area and by mechanical locking. A total of 60 samples were made (15 samples for each group). A total of 15 samples for Group I were prepared with untreated impression copings, 15 samples for Group II with impression copings treated and modified by application of tray adhesive only. Group III includes 15 samples which were fabricated with impression copings modified by making four vertical grooves on surface of impression coping and coated with adhesive. Group IV had 15 samples which were fabricated with impression copings sandblasted with 50 μm aluminum oxide powder and coated with adhesive. Profile projector was used to evaluate the rotational accuracy of the implant analogs by comparing Molar Implant Angle (MIA) and Premolar Implant Angle (PIA) of test samples with reference model. One-way ANOVA and Student t-test were used to analyze the data. One-way ANOVA didn't show any significant differences for both MIA and PIA between the Groups I, II, III and IV. Student's unpaired t-test revealed no significant difference in the mean MIA and mean PIA. Conclusion: Though results were statistically non-significant, all types of surface treatments of the impression copings showed more accurate transfer than those with no treatment. Sandblasted and adhesive coated impression copings showed minimum amount of rotation followed by those with vertical slots and adhesive coated impression copings.

  9. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNBmore » with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.« less

  10. The similia principle: results obtained in a cellular model system.

    PubMed

    Wiegant, Fred; Van Wijk, Roeland

    2010-01-01

    This paper describes the results of a research program focused on the beneficial effect of low dose stress conditions that were applied according to the similia principle to cells previously disturbed by more severe stress conditions. In first instance, we discuss criteria for research on the similia principle at the cellular level. Then, the homologous ('isopathic') approach is reviewed, in which the initial (high dose) stress used to disturb cellular physiology and the subsequent (low dose) stress are identical. Beneficial effects of low dose stress are described in terms of increased cellular survival capacity and at the molecular level as an increase in the synthesis of heat shock proteins (hsps). Both phenomena reflect a stimulation of the endogenous cellular self-recovery capacity. Low dose stress conditions applied in a homologous approach stimulate the synthesis of hsps and enhance survival in comparison with stressed cells that were incubated in the absence of low dose stress conditions. Thirdly, the specificity of the low dose stress condition is described where the initial (high dose) stress is different in nature from the subsequently applied (low dose) stress; the heterologous or 'heteropathic' approach. The results support the similia principle at the cellular level and add to understanding of how low dose stress conditions influence the regulatory processes underlying self-recovery. In addition, the phenomenon of 'symptom aggravation' which is also observed at the cellular level, is discussed in the context of self-recovery. Finally, the difference in efficiency between the homologous and the heterologous approach is discussed; a perspective is indicated for further research; and the relationship between studies on the similia principle and the recently introduced concept of 'postconditioning hormesis' is emphasized. Copyright 2009 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.

  11. A comparison of results obtained from foil chaff clouds at 69 deg northern latitude during winter, summer and autumn

    NASA Technical Reports Server (NTRS)

    Widdel, H. U.; Vonzahn, U.

    1989-01-01

    Results from high resolution foil chaff experiments flown during the campaigns MAP/WINE (December 83 to February 84), MAC/SINE (June to July 1987) and Epsilon (October to November 1987) at Andenes (Northern Norway) are compared to each other and the differences in wind direction and wave activity during the different seasons are worked out.

  12. Initial Results Obtained with the First TWIN VLBI Radio Telescope at the Geodetic Observatory Wettzell

    PubMed Central

    Schüler, Torben; Kronschnabl, Gerhard; Plötz, Christian; Neidhardt, Alexander; Bertarini, Alessandra; Bernhart, Simone; la Porta, Laura; Halsig, Sebastian; Nothnagel, Axel

    2015-01-01

    Geodetic Very Long Baseline Interferometry (VLBI) uses radio telescopes as sensor networks to determine Earth orientation parameters and baseline vectors between the telescopes. The TWIN Telescope Wettzell 1 (TTW1), the first of the new 13.2 m diameter telescope pair at the Geodetic Observatory Wettzell, Germany, is currently in its commissioning phase. The technology behind this radio telescope including the receiving system and the tri-band feed horn is depicted. Since VLBI telescopes must operate at least in pairs, the existing 20 m diameter Radio Telescope Wettzell (RTW) is used together with TTW1 for practical tests. In addition, selected long baseline setups are investigated. Correlation results portraying the data quality achieved during first initial experiments are discussed. Finally, the local 123 m baseline between the old RTW telescope and the new TTW1 is analyzed and compared with an existing high-precision local survey. Our initial results are very satisfactory for X-band group delays featuring a 3D distance agreement between VLBI data analysis and local ties of 1 to 2 mm in the majority of the experiments. However, S-band data, which suffer much from local radio interference due to WiFi and mobile communications, are about 10 times less precise than X-band data and require further analysis, but evidence is provided that S-band data are well-usable over long baselines where local radio interference patterns decorrelate. PMID:26263991

  13. Scientific results obtained by the Busot observatory

    NASA Astrophysics Data System (ADS)

    García-Lozano, R.; Rodes, J. J.; Torrejón, J. M.; Bernabéu, G.; Berná, J. Á.

    2016-12-01

    We present the discovery of three new W UMa systems by our group as a part of a photometric follow-up of variable stars carried out with the Busot observatory 36 cm robotic telescope in collaboration with the X-ray astronomy group at University of Alicante (Alicante, Spain). Specifically we show the high limiting magnitude to detect moving objects (V˜ 21 mag), and the high stability and accuracy attained in photometry which allow us to measure very shallow planet transits.

  14. Feather keratin hydrolysates obtained from microbial keratinases: effect on hair fiber

    PubMed Central

    2013-01-01

    Background Hair is composed mainly of keratin protein and a small amount of lipid. Protein hydrolysates, in particular those with low molecular weight distribution have been known to protect hair against chemical and environmental damage. Many types of protein hydrolysates from plants and animals have been used in hair and personal care such as keratin hydrolysates obtained from nails, horns and wool. Most of these hydrolysates are obtained by chemical hydrolysis and hydrothermal methods, but recently hydrolyzed hair keratin, feather keratin peptides, and feather meal peptides have been obtained by enzymatic hydrolysis using Bacillus spp in submerged fermentation. Results Keratin peptides were obtained by enzymatic hydrolysis of keratinases using Bacillus subtilis AMR. The microorganism was grown on a feather medium, pH 8.0 (1% feathers) and supplemented with 0.01% of yeast extract, for 5 days, at 28°C with agitation. The supernatant containing the hydrolysates was colleted by centrifugation and ultra filtered in an AMICON system using nano–membranes (Millipore – YC05). The Proteins and peptides were analyzed using HPTLC and MALDI-TOF-MS. Commercial preparations of keratin hydrolysates were used as a comparative standard. After five days the feather had been degraded (90-95%) by the peptidases and keratinases of the microorganism. MALDI-TOF mass spectrometry showed multiple peaks that correspond to peptides in the range of 800 to 1079 Daltons and the commercial hydrolysate was in the range of 900 to 1400 Da. HPTLC showed lower molecular mass peptides and amino acids in the enzymatic hydrolysate when compared with the commercial hydrolysate . A mild shampoo and a rinse off conditioner were formulated with the enzymatic hydrolysate and applied to hair fibers to evaluate the hydration, with and without heat, using a Corneometer® CM 825. The hydration was more efficient with heat, suggesting a more complete incorporation of hydrolysates into the fibers

  15. Validation of Observations Obtained with a Liquid Mirror Telescope by Comparison with Sloan Digital Sky Survey Observations

    NASA Astrophysics Data System (ADS)

    Borra, E. F.

    2015-06-01

    The results of a search for peculiar astronomical objects using very low resolution spectra obtained with the NASA Orbital Debris Observatory (NODO) 3 m diameter liquid mirror telescope (LMT) are compared with results of spectra obtained with the Sloan Digital Sky Survey (SDSS). The main purpose of this comparison is to verify whether observations taken with this novel type of telescope are reliable. This comparison is important because LMTs are an inexpensive novel type of telescope that is very useful for astronomical surveys, particularly surveys in the time domain, and validation of the data taken with an LMT by comparison with data from a classical telescope will validate their reliability. We start from a published data analysis that classified as peculiar only 206 of the 18,000 astronomical objects observed with the NODO LMT. A total of 29 of these 206 objects were found in the SDSS. The reliability of the NODO data can be seen through the results of the detailed analysis that, in practice, incorrectly identified less than 0.3% of the 18,000 spectra as peculiar objects, most likely because they are variable stars. We conclude that the LMT gave reliable observations, comparable to those that would have been obtained with a telescope using a glass mirror.

  16. Coating multilayer material with improved tribological properties obtained by magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Mateescu, A. O.; Mateescu, G.; Balasoiu, M.; Pompilian, G. O.; Lungu, M.

    2017-02-01

    This work is based on the Patent no. RO 128094 B1, granted by the Romanian State Office for Inventions and Trademarks. The goal of the work is to obtain for investigations tribological coatings with multilayer structure with improved tribological properties, deposited by magnetron sputtering process from three materials (sputtering targets). Starting from compound chemical materials (TiC, TiB2 and WC), as sputtering targets, by deposition in argon atmosphere on polished stainless steel, we have obtained, based on the claims of the above patent, thin films of multilayer design with promising results regarding their hardness, elastic modulus, adherence, coefficient of friction and wear resistance. The sputtering process took place in a special sequence in order to ensure better tribological properties to the coating, comparing to those of the individual component materials. The tribological properties, such as the coefficient of friction, are evaluated using the tribometer test.

  17. [Properties of pectolitic phytopathogenic bacteria isolates obtained in Ukraine].

    PubMed

    Maksimenko, L A; Parkhomenko, N I; Moroz, S N; Gorb, T E

    2013-01-01

    Bacteria obtained from potato tubers having symptoms of soft rot and grown in different regions of Ukraine are identified as Pectobacterium carotovorum subsp. carotovorum. These bacteria strains are able to produce bacteriocines. Their killer activity in respect of P. carotovorum and Esherichia coli has been studied. The sensitivity to bactericines has been shown. Purified fractions of bacteriocines having high molecular weight (MCTV) have been obtained. The difference in composition of proteins from phage tails as compared to the ones in P. carotovorum J2 has been studied by the method of electrophoresis. It was found that the composition of MCTV major proteins of studied isolates mostly corresponds to P. carotovorum J2. The set of enzyme minor fractions has some different compositions as compared to P. carotovorum J2. It has been hypothesized that this difference is responsible for killer specificity.

  18. [Evaluation of the depth of infiltration of urothelial carcinoma in the vesical wall obtained by transurethral intravesical echotomography].

    PubMed

    Milosević, Radovan; Milović, Novak; Stijelja, Borislav; Dokić, Milan; Campara, Zoran; Mocović, Dejan

    2007-10-01

    Transitional cell carcinoma (TCC) is the most frequent tumor of the bladder and represents 95-98% of blader neoplasams and 2-3% of all carcinomas in the body. In urogenital oncology more frequent is only prostatic cancer. Evaluation of the depth of infiltration of urothelial carcinoma in the vesical wall represents the clinical base in treatment planning and prognosis. Clinical investigation and convential radiological procedures have a low level of accuracy in estimating the local growth of the tumor. The aims of our investigation were to determine the depth of infiltration of urothelial carcinoma in the vesical wall in the investigated group of patients by transurethral intravesical echotomography (TIE) and computerised tomography (CT scan) and to compare results obtained by both methods with pathohistological (PH) results, and, based on the difference of the results determine which method was more accurate in the evaluation of the depth of infiltration of urothelial carcinoma in the vesical wall. Thirty patients with TCC of the bladder both genders, aged 51-81 years were involved in our investigation. In all of these patients, radical cystectomy (RC) was performed. This was neccessary to provide the defintive PH result. Transurethral intravesical echotomography was performed by ultrasound scanner type 1846 Bruel and Kjaer, sond type 1850, and the CT scan was perfomed by Pace plus, General Electric, U.S.A. The specimen for the definitive PH result obtained by RC includes all standards of the TNM classification. Using CT scan, the most frequent was T1 stage (17 patients or 56.68%). Using TIE, the most frequent was T2 stage (22 patients or 73.33%). After RC the most frequent was T2 stage (21 patients or 70%). The Kolmogorov-Smirnov test, showed a high significant difference between the results obtained using CT and definitive PH results after RC. The same test showed no statistically significant difference between the results obtained using TIE and definitive PH

  19. Comparative Analysis of Different Measurement Techniques for MLC Characterization: Preliminary Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larraga-Gutierrez, J. M.; Ballesteros-Zebadua, P.; Garcia-Garduno, O. A.

    2008-08-11

    Radiation transmission, leakage and beam penumbra are essential dosimetric parameters related to the commissioning of a multileaf collimation system. This work shows a comparative analysis of commonly used film detectors: X-OMAT V2 and EDR2 radiographic films, and GafChromic EBT registered radiochromic film. The results show that X-OMAT over-estimates radiation leakage and 80-20% beam penumbra. However, according to the reference values reported by the manufacturer for these dosimetric parameters, all three films are adequate for MLC dosimetric characterization, but special care must be taken when X-OMAT V2 film is used due to its low energy photon dependence.

  20. A 1 kg Mass Comparator Using Flexure-Strip Suspensions: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Quinn, T. J.; Speake, C. C.; Davis, R. S.

    1986-01-01

    This paper describes the design and construction of a novel form of equal-arm balance. The balance has been designed to study the performance of flexure strips for use as pivots in a 1 kg mass comparator working at the highest accuracy. The beam of the balance is servo controlled using optical detection of angular position and electromagnetic control. Small mass differences are measured in terms of the differences in the servo currents required to reproduce the same position of the beam. Preliminary results using this prototype balance indicate that an accuracy in mass comparison of about 5 parts in 1010 can be achieved.

  1. Comparative cost analysis of inpatient integrative medicine-Results of a pilot study.

    PubMed

    Ostermann, Thomas; Lauche, Romy; Cramer, Holger; Dobos, Gustav

    2017-06-01

    Costs of integrative treatment alone and in comparison with other treatment approaches have scarcely been reported in the past. This study presents results of a comparative cost analysis of an inpatient integrative medicine treatment costs. Data from 2006 for inpatients referred to a Department of Integrative Medicine in Germany were used. Case-related treatment costs were calculated, and transformed into Casemix-Indices and revenues per DRG. Costs were compared between departments at the same hospital and between different hospitals using univariate statistics and Chi-Square tests. In total 1253 inpatients (81.4% female, 61.1±14.4years) were included in the current analysis. Most patients were treated for diseases of the musculoskeletal system (57.2%), followed by diseases of the digestive system (11.4%), and diseases of the nervous system (10.4%). The department received an additional payment for most of the patients (88.0%), which led to an effective appreciation of 10.8% per case compared to the standardized Casemix-Index. In-house comparisons with other departments found the department in close vicinity to the departments of Internal medicine with regards to CMI and mean revenue, however the Patient Clinical Complexity Level was significantly lower in the Integrative medicine department. The interhospital comparison revealed comparable Casemix-Index and DRG-revenue, however the additional payment increased the mean revenue significantly. Modern integrative in-patient treatment is mostly cost-equivalent to conventional treatment. Cost effectiveness studies should be considered to further investigate the potential of integrative in patient treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A multi-scale methodology for comparing GCM and RCM results over the Eastern Mediterranean

    NASA Astrophysics Data System (ADS)

    Samuels, Rana; Krichak, Simon; Breitgand, Joseph; Alpert, Pinhas

    2010-05-01

    The importance of skillful climate modeling is increasingly being realized as results are being incorporated into environmental, economic, and even business planning. Global circulation models (GCMs) employed by the IPCC provide results at spatial scales of hundreds of kilometers, which is useful for understanding global trends but not appropriate for use as input into regional and local impacts models used to inform policy and development. To address this shortcoming, regional climate models (RCMs) which dynamically downscale the results of the GCMs are used. In this study we present first results of a dynamically downscaled RCM focusing on the Eastern Mediterranean region. For the historical 1960-2000 time period, results at a spatial scale of both 25 km and 50 km are compared with historical station data from 5 locations across Israel as well as with the results of 3 GCM models (ECHAM5, NOAA GFDL, and CCCMA) at annual, monthly and daily time scales. Results from a recently completed Japanese GCM at a spatial scale of 20 km are also included. For the historical validation period, we show that as spatial scale increases the skill in capturing annual and inter-annual temperature and rainfall also increases. However, for intra-seasonal rainfall characteristics important for hydrological and agricultural planning (eg. dry and wet spells, number of rain days) the GCM results (including the 20 km Japanese model) capture the historical trends better than the dynamically downscaled RegCM. For future scenarios of temperature and precipitation changes, we compare results across the models for the available time periods, generating a range of future trends.

  3. Gold nanoparticle assemblies of controllable size obtained by hydroxylamine reduction at room temperature

    NASA Astrophysics Data System (ADS)

    Tódor, István Sz.; Szabó, László; Marişca, Oana T.; Chiş, Vasile; Leopold, Nicolae

    2014-12-01

    Colloidal nanoparticle assemblies (NPAs) were obtained in a one-step procedure, by reduction of HAuCl4 by hydroxylamine hydrochloride, at room temperature, without the use of any additional nucleating agent. By changing the order of the reactants, NPAs with mean size of 20 and 120 nm were obtained. Because of their size and irregular popcorn like shape, the larger size NPAs show absorption in the NIR spectral region. The building blocks of the resulted nanoassemblies are spherical nanoparticles with diameters of 4-8 and 10-30 nm, respectively. Moreover, by stabilizing the colloid with bovine serum albumin at different time moments after synthesis, NPAs of controlled size between 20 and 120 nm, could be obtained. The NPAs were characterized using UV-Vis spectroscopy, TEM and SEM electron microscopies. In addition, the possibility of using the here proposed NPAs as surface-enhanced Raman scattering (SERS) substrate was assessed and found to provide a higher enhancement compared to conventional citrate-reduced nanoparticles.

  4. Synthesis and characterization of hematite pigment obtained from a steel waste industry.

    PubMed

    Prim, S R; Folgueras, M V; de Lima, M A; Hotza, D

    2011-09-15

    Pigments that meet environmental and technology requirements are the focus of the research in the ceramic sector. This study focuses on the synthesis of ceramic pigment by encapsulation of hematite in crystalline and amorphous silica matrix. Iron oxide from a metal sheet rolling process was used as chromophore. A different content of hematite and silica was homogenized by conventional and high energy milling. The powders obtained after calcinations between 1050 and 1200 °C for 2h were characterized by X-ray diffraction and SEM analysis. The pigments were applied to ceramic enamel and porcelain body. The effect of pigment was measured by comparing L*a*b* values of the heated samples. Results showed that the color developed is influenced by variables such as oxide content employed, conditions of milling and processing temperature. The results showed that the use of pigment developed does not interfere in microstructural characteristics of pigmented material. The best hue was obtained from samples with 15 wt% of chromophore, heated at 1200 °C in amorphous silica matrix. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Preliminary Results from Duplex Procedure for Obtain of Fe Based Materials for Automotive Applications

    NASA Astrophysics Data System (ADS)

    Crăciun, R. C.; Stanciu, S.; Geantă, V.; Voiculescu, I.; Manole, V.; Gârneţ, I. A.; Alexandru, A.; Cimpoesu, N.; Săndulache, F.

    2017-06-01

    Abstract Iron based materials still represent a high percentage from metallic materials used in industry, in general, and in automotive industry, in particular. In this case we used a duplex process in order to obtain the FeMnSiAl experimental alloy for a more efficient use of various units. In the first stage iron, manganese, silicon and aluminum were melted and mixed together using arc melting technology and for the second stage the alloy was re-melt for homogeneity in an induction furnace. Chemical composition, after each melting step, was analyzed using EDS Bruker detector for various areas and microstructural characterization using SEM, VegaTescan LMH II with SE detector, equipment. This alloy is proposed as a metallic approach of mechanical dumpers used in automotive industry for low and medium impact contacts.

  6. Αntioxidant activity of Cynara scolymus L. and Cynara cardunculus L. extracts obtained by different extraction techniques.

    PubMed

    Kollia, Eleni; Markaki, Panagiota; Zoumpoulakis, Panagiotis; Proestos, Charalampos

    2017-05-01

    Extracts of different parts (heads, bracts and stems) of Cynara cardunculus L. (cardoon) and Cynara scolymus L. (globe artichoke), obtained by two different extraction techniques (Ultrasound-Assisted Extraction (UAE) and classical extraction (CE)) were examined and compared for their total phenolic content (TPC) and their antioxidant activity. Moreover, infusions of the plant's parts were also analysed and compared to aforementioned samples. Results showed that cardoon's heads extract (obtained by Ultrasound-Assisted Extraction) displayed the highest TPC values (1.57 mg Gallic Acid Equivalents (GAE) g -1 fresh weight (fw)), the highest DPPH • scavenging activity (IC50; 0.91 mg ml -1 ) and the highest ABTS •+ radical scavenging capacity (2.08 mg Trolox Equivalents (TE) g -1 fw) compared to infusions and other extracts studied. Moreover, Ultrasound-Assisted Extraction technique proved to be more appropriate and effective for the extraction of antiradical and phenolic compounds.

  7. Methodological approaches to conducting pilot and proof tests on reverse-osmosis systems: Results of comparative studies

    NASA Astrophysics Data System (ADS)

    Panteleev, A. A.; Bobinkin, V. V.; Larionov, S. Yu.; Ryabchikov, B. E.; Smirnov, V. B.; Shapovalov, D. A.

    2017-10-01

    When designing large-scale water-treatment plants based on reverse-osmosis systems, it is proposed to conduct experimental-industrial or pilot tests for validated simulation of the operation of the equipment. It is shown that such tests allow establishing efficient operating conditions and characteristics of the plant under design. It is proposed to conduct pilot tests of the reverse-osmosis systems on pilot membrane plants (PMPs) and test membrane plants (TMPs). The results of a comparative experimental study of pilot and test membrane plants are exemplified by simulating the operating parameters of the membrane elements of an industrial plant. It is concluded that the reliability of the data obtained on the TMP may not be sufficient to design industrial water-treatment plants, while the PMPs are capable of providing reliable data that can be used for full-scale simulation of the operation of industrial reverse-osmosis systems. The test membrane plants allow simulation of the operating conditions of individual industrial plant systems; therefore, potential areas of their application are shown. A method for numerical calculation and experimental determination of the true selectivity and the salt passage are proposed. An expression has been derived that describes the functional dependence between the observed and true salt passage. The results of the experiments conducted on a test membrane plant to determine the true value of the salt passage of a reverse-osmosis membrane are exemplified by magnesium sulfate solution at different initial operating parameters. It is shown that the initial content of a particular solution component has a significant effect on the change in the true salt passage of the membrane.

  8. Comparative Analysis of the Principal Characteristics of Microsilica Obtained from Silicon Manufacture Wastes and Used in Concrete Production Technologies

    NASA Astrophysics Data System (ADS)

    Balabanov, V. B.; Putsenko, K. N.

    2017-11-01

    On the basis of the survey of foreign and domestic literature over the past 65 years devoted to the study of the properties and the technology of applying microsilica in the capacity of modifying additives to concretes. Microsilica obtained as a by-product from the waste of ferroalloy plants and from the plants involved in production of silicon compounds is discussed. Analysis of the principal characteristics of different types of microsilica obtained from different sources is conducted.

  9. Obtaining orthotropic elasticity tensor using entries zeroing method.

    NASA Astrophysics Data System (ADS)

    Gierlach, Bartosz; Danek, Tomasz

    2017-04-01

    A generally anisotropic elasticity tensor obtained from measurements can be represented by a tensor belonging to one of eight material symmetry classes. Knowledge of symmetry class and orientation is helpful for describing physical properties of a medium. For each non-trivial symmetry class except isotropic this problem is nonlinear. A common method of obtaining effective tensor is a choosing its non-trivial symmetry class and minimizing Frobenius norm between measured and effective tensor in the same coordinate system. Global optimization algorithm has to be used to determine the best rotation of a tensor. In this contribution, we propose a new approach to obtain optimal tensor, with the assumption that it is orthotropic (or at least has a similar shape to the orthotropic one). In orthotropic form tensor 24 out of 36 entries are zeros. The idea is to minimize the sum of squared entries which are supposed to be equal to zero through rotation calculated with optimization algorithm - in this case Particle Swarm Optimization (PSO) algorithm. Quaternions were used to parametrize rotations in 3D space to improve computational efficiency. In order to avoid a choice of local minima we apply PSO several times and only if we obtain similar results for the third time we consider it as a correct value and finish computations. To analyze obtained results Monte-Carlo method was used. After thousands of single runs of PSO optimization, we obtained values of quaternion parts and plot them. Points concentrate in several points of the graph following the regular pattern. It suggests the existence of more complex symmetry in the analyzed tensor. Then thousands of realizations of generally anisotropic tensor were generated - each tensor entry was replaced with a random value drawn from normal distribution having a mean equal to measured tensor entry and standard deviation of the measurement. Each of these tensors was subject of PSO based optimization delivering quaternion for optimal

  10. Free-radical scavenging activity and antibacterial impact of Greek oregano isolates obtained by SFE.

    PubMed

    Stamenic, Marko; Vulic, Jelena; Djilas, Sonja; Misic, Dusan; Tadic, Vanja; Petrovic, Slobodan; Zizovic, Irena

    2014-12-15

    The antioxidant and antibacterial properties of Greek oregano extracts obtained by fractional supercritical fluid extraction (SFE) with carbon dioxide were investigated and compared with the properties of essential oil obtained by hydrodistillation. According to DPPH, hydroxyl radical and superoxide anion radical scavenging activity assays, the supercritical extracts expressed stronger antioxidant activity comparing to the essential oil. The most effective was the supercritical extract obtained by fractional extraction at 30 MPa and 100°C after the volatile fraction had been extracted at lower pressure. At the same time this extract showed strong antibacterial activity against staphylococci, including MRSA strain, but did not affect Escherichia coli of normal intestinal flora. The essential oil obtained by hydrodistillation showed stronger antibacterial activity against E. coli, Salmonella and Klebsiella pneumoniae, comparing to the supercritical extracts but at the same affected the normal gut flora. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Image enhancement by spatial frequency post-processing of images obtained with pupil filters

    NASA Astrophysics Data System (ADS)

    Estévez, Irene; Escalera, Juan C.; Stefano, Quimey Pears; Iemmi, Claudio; Ledesma, Silvia; Yzuel, María J.; Campos, Juan

    2016-12-01

    The use of apodizing or superresolving filters improves the performance of an optical system in different frequency bands. This improvement can be seen as an increase in the OTF value compared to the OTF for the clear aperture. In this paper we propose a method to enhance the contrast of an image in both its low and its high frequencies. The method is based on the generation of a synthetic Optical Transfer Function, by multiplexing the OTFs given by the use of different non-uniform transmission filters on the pupil. We propose to capture three images, one obtained with a clear pupil, one obtained with an apodizing filter that enhances the low frequencies and another one taken with a superresolving filter that improves the high frequencies. In the Fourier domain the three spectra are combined by using smoothed passband filters, and then the inverse transform is performed. We show that we can create an enhanced image better than the image obtained with the clear aperture. To evaluate the performance of the method, bar tests (sinusoidal tests) with different frequency content are used. The results show that a contrast improvement in the high and low frequencies is obtained.

  12. [Difference between perinatal mortality in multiple pregnancies obtained spontaneously versus assisted reproduction].

    PubMed

    del Rayo Rivas-Ortiz, Yazmín; Hernández-Herrera, Ricardo Jorge

    2010-06-01

    Recently assisted reproduction techniques are more common, which increases multiple pregnancies and adverse perinatal outcomes. Some authors report increased mortality in multiple pregnancies products obtained by techniques of assisted reproduction vs. conceived spontaneously, although other authors found no significant difference. To evaluate mortality rate of multiple pregnancies comparing those obtained by assisted reproduction vs. spontaneous conception. Retrospective, observational and comparative study. We included pregnant women with 3 or more products that went to the Unidad Médica de Alta Especialidad No. 23, IMSS, in Monterrey, NL (Mexico), between 2002-2008. We compared the number of complicated pregnancies and dead products obtained by a technique of assisted reproduction vs. spontaneous. 68 multiple pregnancies were included. On average, spontaneously conceived fetuses had more weeks of gestation and more birth weight than those achieved by assisted reproduction techniques (p = ns). 20.5% (14/68) of multiple pregnancies had one or more fatal events: 10/40 (25%) by assisted reproduction techniques vs. 4/28 (14%) of spontaneous multiple pregnancies (p = 0.22). 21/134 (16%) of the products conceived by assisted reproduction techniques and 6/88 (7%) of spontaneous (p < 0.03) died. 60% of all multiple pregnancies were obtained by a technique of assisted reproduction and 21% of the cases had one or more fatal events (11% more in pregnancies achieved by assisted reproduction techniques). 12% of the products of multiple pregnancies died (9% more in those obtained by a technique of assisted reproduction).

  13. Method for obtaining structure and interactions from oriented lipid bilayers

    PubMed Central

    Lyatskaya, Yulia; Liu, Yufeng; Tristram-Nagle, Stephanie; Katsaras, John; Nagle, John F.

    2009-01-01

    Precise calculations are made of the scattering intensity I(q) from an oriented stack of lipid bilayers using a realistic model of fluctuations. The quantities of interest include the bilayer bending modulus Kc , the interbilayer interaction modulus B, and bilayer structure through the form factor F(qz). It is shown how Kc and B may be obtained from data at large qz where fluctuations dominate. Good estimates of F(qz) can be made over wide ranges of qz by using I(q) in q regions away from the peaks and for qr≠0 where details of the scattering domains play little role. Rough estimates of domain sizes can also be made from smaller qz data. Results are presented for data taken on fully hydrated, oriented DOPC bilayers in the Lα phase. These results illustrate the advantages of oriented samples compared to powder samples. PMID:11304287

  14. A comparative study of Sephadex, glass wool and Percoll separation techniques on sperm quality and IVF results for cryopreserved bovine semen.

    PubMed

    Lee, Hae-Lee; Kim, Sue-Hee; Ji, Dong-Beom; Kim, Yong-Jun

    2009-09-01

    The aim of this study was to compare the effects of spermatozoa separation techniques on sperm quality and in-vitro fertilization (IVF) results for cryopreserved bovine semen. Sephadex, glass wool and Percoll gradient separation techniques were used for sperm separation and sperm motility, morphology and membrane integrity were evaluated before and after separation. Also, cleavage and blastocyst developmental rate were investigated after IVF with sperm recovered by each separation technique. The motility of samples obtained by the three separation techniques were greater compared to the control samples (p < 0.05). The percentage of spermatozoa with intact plasma-membrane integrity, identified by 6-carboxyfluoresceindiacetate/ propidium iodide fluorescent staining and the hypo-osmotic swelling test, was highest in the glass wool filtration samples (p < 0.05). The cleavage and blastocyst rate of total oocytes produced from glass wool filtration samples were also higher than the control and Sephadex filtration samples (p < 0.05), but were not significantly different from Percoll separation samples. However, a significantly greater number of cleaved embryos produced by glass wool filtration developed to blastocyst stage than those produced by Percoll separation (p < 0.05). These results indicate that spermatozoa with good quality can be achieved by these three separation techniques and can be used for bovine IVF. In particular, it suggests that glass wool filtration would be the most effective method of the three for improving sperm quality and embryo production for cryopreserved bovine spermatozoa.

  15. Techniques for obtaining subjective response to vertical vibration

    NASA Technical Reports Server (NTRS)

    Clarke, M. J.; Oborne, D. J.

    1975-01-01

    Laboratory experiments were performed to validate the techniques used for obtaining ratings in the field surveys carried out by the University College of Swansea. In addition, attempts were made to evaluate the basic form of the human response to vibration. Some of the results obtained by different methods are described.

  16. Yes, one can obtain better quality structures from routine X-ray data collection.

    PubMed

    Sanjuan-Szklarz, W Fabiola; Hoser, Anna A; Gutmann, Matthias; Madsen, Anders Østergaard; Woźniak, Krzysztof

    2016-01-01

    Single-crystal X-ray diffraction structural results for benzidine dihydrochloride, hydrated and protonated N,N,N,N-peri(dimethylamino)naphthalene chloride, triptycene, dichlorodimethyltriptycene and decamethylferrocene have been analysed. A critical discussion of the dependence of structural and thermal parameters on resolution for these compounds is presented. Results of refinements against X-ray data, cut off to different resolutions from the high-resolution data files, are compared to structural models derived from neutron diffraction experiments. The Independent Atom Model (IAM) and the Transferable Aspherical Atom Model (TAAM) are tested. The average differences between the X-ray and neutron structural parameters (with the exception of valence angles defined by H atoms) decrease with the increasing 2θmax angle. The scale of differences between X-ray and neutron geometrical parameters can be significantly reduced when data are collected to the higher, than commonly used, 2θmax diffraction angles (for Mo Kα 2θmax > 65°). The final structural and thermal parameters obtained for the studied compounds using TAAM refinement are in better agreement with the neutron values than the IAM results for all resolutions and all compounds. By using TAAM, it is still possible to obtain accurate results even from low-resolution X-ray data. This is particularly important as TAAM is easy to apply and can routinely be used to improve the quality of structural investigations [Dominiak (2015 ▸). LSDB from UBDB. University of Buffalo, USA]. We can recommend that, in order to obtain more adequate (more accurate and precise) structural and displacement parameters during the IAM model refinement, data should be collected up to the larger diffraction angles, at least, for Mo Kα radiation to 2θmax = 65° (sin θmax/λ < 0.75 Å(-1)). The TAAM approach is a very good option to obtain more adequate results even using data collected to the lower 2θmax angles. Also

  17. Spectroscopy of Cosmic Carbon Analogs in Inert-Gas Matrices and in the Gas-Phase: Comparative Results and Perspectives for Astrophysics

    NASA Technical Reports Server (NTRS)

    Salama, Farid; DeVincenzi, Donald L. (Technical Monitor)

    2001-01-01

    Recent studies of the spectroscopy of large (up to approx. 50 carbon atoms) neutral and Ionized polycyclic aromatic hydrocarbons (PAHs) and Fullerenes isolated in inert gas matrices will be presented. The advantages and the limitations of matrix isolation spectroscopy for the study of the molecular spectroscopy of interstellar dust analogs will be discussed. The laboratory data will be compared to the astronomical spectra (the interstellar extinction, the diffuse interstellar bands). Finally, the spectra of PAH ions isolated in neon/argon matrices will be compared to the spectra obtained for PAH ion seeded in a supersonic expansion. The astrophysical implications and future perspectives will be discussed.

  18. Comparative effectiveness of colony-stimulating factors in febrile neutropenia prophylaxis: how results are affected by research design.

    PubMed

    Henk, Henry J; Li, Xiaoyan; Becker, Laura K; Xu, Hairong; Gong, Qi; Deeter, Robert G; Barron, Richard L

    2015-01-01

    To examine the impact of research design on results in two published comparative effectiveness studies. Guidelines for comparative effectiveness research have recommended incorporating disease process in study design. Based on the recommendations, we develop a checklist of considerations and apply the checklist in review of two published studies on comparative effectiveness of colony-stimulating factors. Both studies used similar administrative claims data, but different methods, which resulted in directionally different estimates. Major design differences between the two studies include: whether the timing of intervention in disease process was identified and whether study cohort and outcome assessment period were defined based on this temporal relationship. Disease process and timing of intervention should be incorporated into the design of comparative effectiveness studies.

  19. Three-Dimensional Temperature and Wind Profiles Obtained Using UAV-Based Acoustic Atmospheric Tomography

    NASA Astrophysics Data System (ADS)

    Finn, A.

    2017-12-01

    The natural sound generated by an unmanned aerial vehicle is used in conjunction with tomography to remotely sense atmospheric temperature and wind profiles simultaneously. Sound fields recorded onboard the aircraft and by an array of microphones on the ground are compared and converted to sound speed estimates for the ray paths intersecting the intervening medium. Tomographic inversion is then used to transform these sound speed values into vertical cross-sections and 3D volumes of virtual temperature and wind vectors, which enables the atmosphere to be visualised and monitored over time up to altitudes of 1,200m and over baselines of up to 600m. This paper reports on results from two short campaigns during which 2D and 3D profiles of wind and temperature obtained in this way were compared to: measurements taken by co-located mid-range Doppler SODAR and LIDAR; and temperature measurements made by instruments carried by unmanned aircraft flying through the intervening atmosphere. Large eddy simulation of daytime atmospheric boundary layers were also used to examine the anticipated performance of the instruments and the nature of any errors. The observations obtained using all systems are shown to correspond closely.

  20. Innovative Formulation Combining Al, Zr and Si Precursors to Obtain Anticorrosion Hybrid Sol-Gel Coating.

    PubMed

    Genet, Clément; Menu, Marie-Joëlle; Gavard, Olivier; Ansart, Florence; Gressier, Marie; Montpellaz, Robin

    2018-05-10

    The aim of our study is to improve the aluminium alloy corrosion resistance with Organic-Inorganic Hybrid (OIH) sol-gel coating. Coatings are obtained from unusual formulation with precursors mixing: glycidoxypropyltrimethoxysilane (GPTMS), zirconium (IV) propoxide (TPOZ) and aluminium tri-sec-butoxide (ASB). This formulation was characterized and compared with sol formulations GPTMS/TPOZ and GPTMS/ASB. In each formulation, a corrosion inhibitor, cerium (III) nitrate hexahydrate, is employed to improve the corrosion performance. Coatings obtained from sol based on GPTMS/TPOZ/ASB have good anti-corrosion performances with Natural Salt Spray (NSS) resistance of 500 h for a thickness lower than 4 µm. Contact angle measurement showed a coating hydrophobic behaviour. To understand these performances, nuclear magnetic resonance (NMR) analyses were performed, results make sol-gel coating condensation evident and are in very good agreement with previous results.

  1. Analysis of single-breath profiles of exhaled nitric oxide in children with allergy and asthma: guideline-derived plateau concentrations compared to results of automatic evaluation by two analyzers.

    PubMed

    Chládková, Jirina; Havlínová, Zuzana; Chyba, Tomás; Krcmová, Irena; Chládek, Jaroslav

    2008-11-01

    Current guidelines recommend the single-breath measurement of fractional concentration of exhaled nitric oxide (FE(NO)) at the expiratory flow rate of 50 mL/s as a gold standard. The time profile of exhaled FE(NO) consists of a washout phase followed by a plateau phase with a stable concentration. This study performed measurements of FE(NO) using a chemiluminescence analyzer Ecomedics CLD88sp and an electrochemical monitor NIOX MINO in 82 children and adolescents (44 males) from 4.9 to 18.7 years of age with corticosteroid-treated allergic rhinitis (N = 58) and/or asthma (N = 59). Duration of exhalation was 6 seconds for children less than 12 years of age and 10 seconds for older children. The first aim was to compare the evaluation of FE(NO)-time profiles from Ecomedics by its software in fixed intervals of 7 to 10 seconds (older children) and 2 to 4 seconds (younger children) since the start of exhalation (method A) with the guideline-based analysis of plateau concentrations at variable time intervals (method B). The second aim was to assess the between-analyzer agreement. In children over 12 years of age, the median ratio of FE(NO) concentrations of 1.00 (95% CI: 0.99-1.02) indicated an excellent agreement between the methods A and B. Compared with NIOX MINO, the Ecomedics results were higher by 11% (95% CI: 1-22) (method A) and 14% (95% CI: 4-26) (method B), respectively. In children less than 12 years of age, the FE(NO) concentrations obtained by the method B were 34% (95% CI: 21-48) higher and more reproducible (p < 0.02) compared to the method A. The Ecomedics results of the method A were 11% lower (95% CI: 2-20) than NIOX MINO concentrations while the method B gave 21% higher concentrations (95% CI: 9-35). We conclude that in children less than 12 years of age, the guideline-based analysis of FE(NO)-time profiles from Ecomedics at variable times obtains FE(NO) concentrations that are higher and more reproducible than those from the fixed interval of 2 to 4

  2. Quantity and quality of black carbon molecular markers as obtained by two chromatographic methods (GC-FID and HPLC-DAD) - How do results compare?

    NASA Astrophysics Data System (ADS)

    Schneider, M. P. W.; Smittenberg, R. H.; Dittmar, T.; Schmidt, M. W. I.

    2009-04-01

    Chars produced by wildfires are an important source of black carbon (BC) in the environment. After their deposition on the soil surface they can be distributed into rivers, marine waters and sediments. The analysis of benzenepolycarboxylic acids (BPCAs) as a quantitative measure for black carbon (BC) in soil and sediment samples is a well-established method (Glaser et al., 1998; Brodowski et al., 2005). Briefly, the nitric acid oxidation of fused aromatic ring systems in BC forms eight molecular markers (BPCAs), which can be assigned to BC, and which subsequently can be quantified by GC-FID (gas chromatography with flame ionization detector). Recently, this method was modified for the quantification of BC in seawater samples using HPLC-DAD (High performance liquid chromatography with diode array detector) for the determination of individual BPCAs (Dittmar, 2008). A direct comparison of both analytical techniques is lacking but would be important for future data comparison aimed at the calculation of global BC budgets. Here we present a systematic comparison of the two BPCA quantification methods. We prepared chars under well-defined laboratory conditions. In order to cover a broad spectrum of char properties we used two sources of biomass and a wide range of pyrolysis temperatures. Chestnut hardwood chips (Castanea sativa) and rice straw (Oryza sativa) were pyrolysed at temperatures between 200 and 1000°C under a constant N2 stream. The maximum temperatures were held constant for 5 hours (Hammes et al., 2006). The BC contents of the chars have been analysed using the BPCA extraction method followed by either GC-FID or HPLC-DAD quantification. Preliminary results suggest that both methods yield similar total quantities of BPCA, and also the proportions of the individual markers are similar. Ongoing experiments will allow for a more detailed comparison of the two methods. The BPCA composition of chars formed at different temperatures and from different precursor

  3. Surgical treatment of chronic pancreatitis and its complications. Comparative analysis of results in 91 patients.

    PubMed

    Marinov, V; Draganov, K; Gaydarski, R; Katev, N N

    2013-01-01

    There is a large variety of proposed conservative, invasive, endoscopic and surgical methods for treatment of chronic pancreatitis and its complications. This study presents a comparative analysis of the results from each group of patients subjected to drainage, resection, denervation and other operative techniques for a total of 91 patients with chronic pancreatitis and its complications. Drainage and resection operative techniques yield comparable results in terms of postoperative pain control 93.1% and 100%, perioperative mortality--3.17% and 5.8%, perioperative morbidity--7.9% and 11.7%, respectively. There is a significant increase in the instances of diabetes in the resection group. Right-side semilunar ganglionectomy is a good method for pain control as an accompanying procedure in the course of another main operative technique.

  4. Comparative lifetesting results for microchannel plates in windowless EUV photon detectors

    NASA Technical Reports Server (NTRS)

    Malina, R. F.; Coburn, K. R.

    1984-01-01

    Microchannel plates (MCPs) from seven manufacturers were subjected to a series of tests to determine their suitability for the Extreme Ultraviolet Explorer satellite. Comparative data are presented for sixteen MCP tandem pairs with channel length to diameter ratios (l/d) ranging from 40:1 to 60:1 and for two saturable (curved channel) MCPs with l/d's of 80:1. Results for MCPs with funnelled channel throats are also discussed. Properties of the MCPs which were monitored include: background count rate, output charge pulse height distribution (PHD), modal gain, PHD full width half maximum (FWHM), and extreme ultraviolet (EUV) photon quantum efficiency. Five detectors were chosen for further lifetime testing consisting of a mild bake to 100 C, and charge extraction to 0.01 coulombs, repeated high voltage cycling and reexposure to one atmosphere conditions. The results of these tests and their implications for the flight detectors are discussed. Erratic events in the detector background were recorded, probably due to field emission from high voltage surfaces or the absorption of water vapor into the electrode following exposure to air. The steps taken to control the detector background are discussed.

  5. Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA

    NASA Astrophysics Data System (ADS)

    Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.

    2018-03-01

    Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.

  6. Packaging and Labeling of Pharmaceutical Products Obtained from the Internet

    PubMed Central

    2011-01-01

    Background For patients, the prescription container label may be the only source of instructions on how to take their medicines. In the United States, the legal requirements for a prescription label are set by federal law and state statutes. The container should be comparable to that which manufacturers use to package drug products and should preserve a product’s identity, strength, quality, and purity and prevent contamination. Safety features such as a child-resistant closure should be provided. Pharmaceutical products purchased from international online pharmacies are not approved by the Food and Drug Administration (FDA) and may not meet US guidelines for labeling and packaging. Objective The study objective was to determine whether commonly purchased pharmaceutical products obtained from international online pharmacies are comparable to products dispensed in the United States with regard to labeling and packaging. Methods During March 2006 through January 2007, 41 pharmaceutical oral dosage form samples were obtained from international Internet pharmacy websites for evaluation: 18 generic simvastatin samples, 18 generic amlodipine samples, and 5 generic sildenafil samples. Contents for each package were observed and recorded and comparison of the prescription labeling and packaging of these products was made with prescription labeling and packaging requirements in the United States. Results Of the 41 drug products obtained from online pharmacies from 12 different countries, only 1 product (from Canada) would meet both labeling and packaging guidelines for products dispensed in the United States. Of those not meeting the requirements, 7 were dispensed in paper envelopes with label affixed that was either handwritten or typed and contained missing information such as name and address of dispenser, name of prescriber, name of patient, and directions for use. Another 3 products did not have a label affixed to the drug product, but information was printed on a

  7. Preliminary results of the comparative study between EO-1/Hyperion and ALOS/PALSAR

    NASA Astrophysics Data System (ADS)

    Koizumi, E.; Furuta, R.; Yamamoto, A.

    2011-12-01

    [Introduction]Hyper-spectral remote sensing images have been used for land-cover classification due to their high spectral resolutions. Synthetic Aperture Radar (SAR) remote sensing data are also useful to probe surface condition because radar image reflects surface geometry, although there are not so many reports about the land-cover detection with combination use of both hyper-spectral data and SAR data. Among SAR sensors, L-band SAR is thought to be useful tool to find physical properties because its comparatively long wave length can through small objects on surface. We are comparing the result of land cover classification and/or physical values from hyper-spectral and L-band SAR data to find the relationship between these two quite different sensors and to confirm the possibility of the combined analysis of hyper-spectral and L-band SAR data, and in this presentation we will report the preliminary result of this study. There are only few sources of both hyper-spectral and L-band SAR data from the space in this time, however, several space organizations plan to launch new satellites on which hyper-spectral or L-band SAR equipments are mounted in next few years. So, the importance of the combined analysis will increase more than ever. [Target Area]We are performing and planning analyses on the following areas in this study. (a)South of Cairo, Nile river area, Egypt, for sand, sandstone, limestone, river, crops. (b)Mount Sakurajima, Japan, for igneous rock and other related geological property. [Methods and Results]EO-1 Hyperion data are analyzed in this study as hyper-spectral data. The Hyperion equipment has 242 channels but some of them include full noise or have no data. We selected channels for analysis by checking each channel, and select about 150 channels (depend on the area). Before analysis, the atmospheric correction of ATCOR-3 was applied for the selected channels. The corrected data were analyzed by unsupervised classification or principal component

  8. Comparing spatial series of soil bulk electrical conductivity as obtained by Time Domain Reflectometry and Electrical Resistivity Tomography

    NASA Astrophysics Data System (ADS)

    Saeed, Ali; Dragonetti, Giovanna; Comegna, Allessandro; Garre, Sarah; Lamaddalena, Nicola; Coppola, Antonio

    2016-04-01

    Conventional ground survey of soil root zone salinity by direct soil sampling are time consuming, costly and destructive. Alternatively, soil salinity can be evaluated by measuring the bulk electrical conductivity, σb, in the field. This approach is faster and cheaper, and allows a more intensive surveying. Measurements of σb can be made either in situ or with remote devices. Time domain reflectometry (TDR) sensors allow simultaneous measurements of water content, θ, and σb. They may be calibrated for estimating the electrical conductivity of the soil solution (σw). However, they have a relatively small observation window and thus they are thought to only provide local-scale measurements. The spatial range of the sensors is limited to tens of centimeters and extension of the information to a large area can be problematic. Also, information on the vertical distribution of the σb soil profile may only be obtained by installing sensors at different depths. In this sense, the TDR may be considered as an invasive technique. Compared to the TDR, other geophysical methods based for example on the Electrical Resistivity Tomography (ERT) techniques represent an alternative in respect to those traditional for soil salinity characterization. In order to deduce the actual distribution of the bulk electrical conductivity, σb, in the soil profile, one needs to invert the signal coming from ERT sensors. The latter, in turn, depends on the specific depth distribution of the σb, as well as on the electrical configuration of the sensor used. With these premises, the main aim of this study is to estimate the vertical σb distribution starting from resistivity data series measured using the ERT method under different salinity conditions and using TDR data as ground-truth data for calibration and validation of the ERT sensor. This way, limited measured TDR data may be used for translating extensive ERT apparent electrical conductivity, σa, measurements to estimate depth

  9. Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase A Study

    NASA Astrophysics Data System (ADS)

    Tagliaferri, G.; Basso, S.; Borghi, G.; Burkert, W.; Citterio, O.; Civitani, M.; Conconi, P.; Cotroneo, V.; Freyberg, M.; Garoli, D.; Gorenstein, P.; Hartner, G.; Mattarello, V.; Orlandi, A.; Pareschi, G.; Romaine, S.; Spiga, D.; Valsecchi, G.; Vernani, D.

    2009-05-01

    Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong improvement both in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. The superb hard X-ray imaging capability will be guaranteed by a mirror module of 100 electroformed Nickel shells with a multilayer reflecting coating. Here we will describe the technogical development and solutions adopted for the fabrication of the mirror module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A, terminated at the end of 2008, we have developed three engineering models with two, two and three shells, respectively. The most critical aspects in the development of the Simbol-X mirrors are i) the production of the 100 mandrels with very good surface quality within the timeline of the mission, ii) the replication of shells that must be very thin (a factor of 2 thinner than those of XMM-Newton) and still have very good image quality up to 80 keV, iii) the development of an integration process that allows us to integrate these very thin mirrors maintaining their intrinsic good image quality. The Phase A study has shown that we can fabricate the mandrels with the needed quality and that we have developed a valid integration process. The shells that we have produced so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and effective area. However, we still need to make some improvements to reach the requirements. We will briefly present these results and discuss the possible improvements that we will investigate during phase B.

  10. A comparison of the results obtained with traditional phlebotomy and with therapeutic erythrocytapheresis in patients with erythrocytosis

    PubMed Central

    Vecchio, Sisto; Leonardo, Patrizia; Musuraca, Vittoria; D'Ettoris, Anna Rita; Geremicca, Walter

    2007-01-01

    Background Phlebotomy is the most commonly treatment used for erythrocytosis and polycythaemia. After the introduction in the medical practice of cell separators, erythrocytapheresis has been also introduced. The aim of the study was to compare the clinical results of the two kinds of treatment. Patients and methods We analysed 98 patients affected by different forms of erythrocytosis, divided into three treatment groups: 1) patients undergoing phlebotomy; 2) patients treated only with therapeutic erythrocytapheresis; 3) patients who underwent phlebotomy treatment for a certain period and who were then switched to apheresis treatment. The haematocrit in these patients was maintained at about 45% and they were treated when the haematocrit exceeded the critical threshold of 50%. Results The interval between two therapeutic interventions was assumed as indicator. In 80% of the patients treated only with phlebotomy the interval was between 20 days and 2 months, in subjects treated with only erythrocytapheresis the intevals were between 2 and 7 months. In the third group of patients, the switch from phlebotomy to erythrocytapheresis considerably prolonged the interval. Conclusions The data showed that erythrocytapheresis was clearly superior to traditional phlebotomy in terms of prolonging the period between one treatment and another, independently of the type of erythrocytosis and of the treatment group. PMID:19204747

  11. Efficacy and tolerability of brivaracetam compared to lacosamide, eslicarbazepine acetate, and perampanel as adjunctive treatments in uncontrolled focal epilepsy: Results of an indirect comparison meta-analysis of RCTs.

    PubMed

    Brigo, Francesco; Bragazzi, Nicola Luigi; Nardone, Raffaele; Trinka, Eugen

    2016-11-01

    Brivaracetam (BRV), eslicarbazepine acetate (ESL), lacosamide (LCM), and perampanel (PER) have been recently marketed as adjunctive treatments for focal onset seizures. To date, no randomized controlled trial (RCT) has directly compared BRV with ESL, LCM, or PER. To compare BRV with the other add-on AEDs in patients with uncontrolled focal epilepsy, estimating their efficacy and tolerability through an adjusted, common-reference based indirect comparison meta-analysis. We systematically searched RCTs in which add-on treatment with ESL or LCM in patients with focal onset seizures have been compared with placebo. Efficacy and tolerability outcomes were considered. Random-effects Mantel-Haenszel meta-analyses were performed to obtain odds ratios (ORs) for the efficacy of BRV, LCM, ESL, or PER versus placebo. Adjusted indirect comparisons were then made between BRV and the other three AEDs using the obtained results, comparing the minimum and the highest effective recommended daily dose of each drug. Seventeen RCTs, with a total of 4971 patients were included. After adjusting for dose-effects, indirect comparisons showed no difference between BRV and LCM, ESL, or PER for responder rate and seizure freedom. Lower adverse events were observed with high dose BRV compared to high dose ESL or PER, but no difference was found in withdrawing because of adverse events. Indirect comparisons do not demonstrate a significant difference in efficacy between add-on BRV and LCM, ESL, or PER in focal epilepsy, and might suggest a better tolerability of BRV than ESL, and possibly also PER, at the highest effective recommended dose. Copyright © 2016 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  12. Antimicrobial activity and composition profile of grape (Vitis vinifera) pomace extracts obtained by supercritical fluids.

    PubMed

    Oliveira, Daniela A; Salvador, Ana Augusta; Smânia, Artur; Smânia, Elza F A; Maraschin, Marcelo; Ferreira, Sandra R S

    2013-04-10

    The possibility of increasing the aggregated value of the huge amount of residues generated by wineries around the world foment studies using the grape pomace - the residue from the wine production, composed by seed, skin and stems - to obtain functional ingredients. Nowadays, consumers in general prefer natural and safe products mainly for food and cosmetic fields, where the supercritical fluid extraction is of great importance due to the purity of the extracts provided. Therefore, the objective of this work is to evaluate the global extraction yield, the antimicrobial activity and the composition profile of Merlot and Syrah grape pomace extracts obtained by supercritical CO2 (SC-CO2) and CO2 added with co-solvent at pressures up to 300 bar and temperatures of 50 and 60 °C. The results were compared with the ones obtained by Soxhlet and by ultrasound-assisted leaching extraction methods. The main components from the extracts, identified by HPLC, were gallic acid, p-OH-benzoic acid, vanillic acid and epicatechin. The antibacterial and antifungal activities of the extracts were evaluated using four strains of bacteria (Staphylococcus aureus, Bacillus cereus, Escherichia coli and Pseudomonas aeruginosa) and three fungi strains (Candida albicans, Candida parapsilosis, Candida krusei). Despite lower extraction yield results, the supercritical fluid extracts presented the highest antimicrobial effectiveness compared to the other grape pomace extracts due to the presence of antimicrobial active compounds. Syrah extracts were less efficient against the microorganisms tested and Merlot extracts were more active against Gram-positive bacteria. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Correlation between radio-induced lymphocyte apoptosis measurements obtained from two French centres.

    PubMed

    Mirjolet, C; Merlin, J L; Dalban, C; Maingon, P; Azria, D

    2016-07-01

    In the era of modern treatment delivery, increasing the dose delivered to the target to improve local control might be modulated by the patient's intrinsic radio-sensitivity. A predictive assay based on radio-induced lymphocyte apoptosis quantification highlighted the significant correlation between CD4 and CD8 T-lymphocyte apoptosis and grade 2 or 3 radiation-induced late toxicities. By conducting this assay at several technical platforms, the aim of this study was to demonstrate that radio-induced lymphocyte apoptosis values obtained from two different platforms were comparable. For 25 patients included in the PARATOXOR trial running in Dijon the radio-induced lymphocyte apoptosis results obtained from the laboratory of Montpellier (IRCM, Inserm U1194, France), considered as the reference (referred to as Lab 1), were compared with those from the laboratory located at the Institut de cancérologie de Lorraine (ICL, France), referred to as Lab 2. Different statistical methods were used to measure the agreement between the radio-induced lymphocyte apoptosis data from the two laboratories (quantitative data). The Bland-Altman plot was used to identify potential bias. All statistical tests demonstrated good agreement between radio-induced lymphocyte apoptosis values obtained from both sites and no major bias was identified. Since radio-induced lymphocyte apoptosis values, which predict tolerance to radiotherapy, could be assessed by two laboratories and showed a high level of robustness and consistency, we can suggest that this assay be extended to any laboratories that use the same technique. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  14. A new look on anomalous thermal gradient values obtained in South Portugal

    NASA Astrophysics Data System (ADS)

    Duque, M. R.; Malico, I.

    2012-04-01

    depend on water ascending velocity, permeability values and depth of the aquifer. Comparing the results of our model with the measured values we can obtain information about aquifer depth and temperature.

  15. Disk Diffusion Testing Using Candida sp. Colonies Taken Directly from CHROMagar Candida Medium May Decrease Time Required To Obtain Results

    PubMed Central

    Klevay, Michael; Ebinger, Alex; Diekema, Daniel; Messer, Shawn; Hollis, Richard; Pfaller, Michael

    2005-01-01

    We compared results of disk diffusion antifungal susceptibility testing from Candida sp. strains passaged on CHROMagar and on potato dextrose agar. The overall categorical agreements for fluconazole and voriconazole disk testing were 95% and 98% with 0% and 0.5% very major errors, respectively. Disk diffusion testing by the CLSI (formerly NCCLS) M44-A method can be performed accurately by taking inocula directly from CHROMagar. PMID:16000489

  16. A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model

    PubMed Central

    Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam

    2017-01-01

    Aims and Objective: The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Materials and Methods: Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t-test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Results: Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. Conclusion: CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis. PMID:28852639

  17. Comparing bulk electrical conductivities spatial series obtained by Time Domain Reflectometry and Electromagnetic Induction sensors

    NASA Astrophysics Data System (ADS)

    Saeed, Ali; Ajeel, Ali; dragonetti, giovanna; Comegna, Alessandro; Lamaddalena, Nicola; Coppola, Antonio

    2016-04-01

    The ability to determine and monitor the effects of salts on soils and plants, are of great importance to agriculture. To control its harmful effects, soil salinity needs to be monitored in space and time. This requires knowledge of its magnitude, temporal dynamics, and spatial variability. Conventional ground survey procedures by direct soil sampling are time consuming, costly and destructive. Alternatively, soil salinity can be evaluated by measuring the bulk electrical conductivity (σb) directly in the field. Time domain reflectometry (TDR) sensors allow simultaneous measurements of water content, θ, and σb. They may be calibrated for estimating the electrical conductivity of the soil solution (σw). However, they have a relatively small observation window and thus they are thought to only provide local-scale measurements. The spatial range of the sensors is limited to tens of centimeters and extension of the information to a large area can be problematic. Also, information on the vertical distribution of the σb soil profile may only be obtained by installing sensors at different depths. In this sense, the TDR may be considered as an invasive technique. Compared to the TDR, other geophysical methods based for example on Electromagnetic Induction (EMI) techniques are non-invasive methods and represent a viable alternative to traditional techniques for soil characterization. The problem is that all these techniques give depth-weighted apparent electrical conductivity (σa) measurements, depending on the specific depth distribution of the σb, as well as on the depth response function of the sensor used. In order to deduce the actual distribution of the bulk electrical conductivity, σb, in the soil profile, one needs to invert the signal coming from EMI. Because of their relatively lower observation window, TDR sensors provide quasi-point values and do not adequately integrate the spatial variability of the chemical concentration distribution in the soil

  18. Are Bibliographic Management Software Search Interfaces Reliable?: A Comparison between Search Results Obtained Using Database Interfaces and the EndNote Online Search Function

    ERIC Educational Resources Information Center

    Fitzgibbons, Megan; Meert, Deborah

    2010-01-01

    The use of bibliographic management software and its internal search interfaces is now pervasive among researchers. This study compares the results between searches conducted in academic databases' search interfaces versus the EndNote search interface. The results show mixed search reliability, depending on the database and type of search…

  19. Comparative Analysis of River Flow Modelling by Using Supervised Learning Technique

    NASA Astrophysics Data System (ADS)

    Ismail, Shuhaida; Mohamad Pandiahi, Siraj; Shabri, Ani; Mustapha, Aida

    2018-04-01

    The goal of this research is to investigate the efficiency of three supervised learning algorithms for forecasting monthly river flow of the Indus River in Pakistan, spread over 550 square miles or 1800 square kilometres. The algorithms include the Least Square Support Vector Machine (LSSVM), Artificial Neural Network (ANN) and Wavelet Regression (WR). The forecasting models predict the monthly river flow obtained from the three models individually for river flow data and the accuracy of the all models were then compared against each other. The monthly river flow of the said river has been forecasted using these three models. The obtained results were compared and statistically analysed. Then, the results of this analytical comparison showed that LSSVM model is more precise in the monthly river flow forecasting. It was found that LSSVM has he higher r with the value of 0.934 compared to other models. This indicate that LSSVM is more accurate and efficient as compared to the ANN and WR model.

  20. [Comparative results of preimplantation genetic screening by array comparative genomic hybridization and new-generation sequencing].

    PubMed

    Aleksandrova, N V; Shubina, E S; Ekimov, A N; Kodyleva, T A; Mukosey, I S; Makarova, N P; Kulakova, E V; Levkov, L A; Barkov, I Yu; Trofimov, D Yu; Sukhikh, G T

    2017-01-01

    Aneuploidies as quantitative chromosome abnormalities are a main cause of failed development of morphologically normal embryos, implantation failures, and early reproductive losses. Preimplantation genetic screening (PGS) allows a preselection of embryos with a normal karyotype, thus increasing the implantation rate and reducing the frequency of early pregnancy loss after IVF. Modern PGS technologies are based on a genome-wide analysis of the embryo. The first pilot study in Russia was performed to assess the possibility of using semiconductor new-generation sequencing (NGS) as a PGS method. NGS data were collected for 38 biopsied embryos and compared with the data from array comparative genomic hybridization (array-CGH). The concordance between the NGS and array-CGH data was 94.8%. Two samples showed the karyotype 47,XXY by array-CGH and a normal karyotype by NGS. The discrepancies may be explained by loss of efficiency of array-CGH amplicon labeling.

  1. How does a bilingual environment affect the results in children with cochlear implants compared to monolingual-matched children? An Italian follow-up study.

    PubMed

    Forli, Francesca; Giuntini, Giada; Ciabotti, Annalisa; Bruschini, Luca; Löfkvist, Ulrika; Berrettini, Stefano

    2018-02-01

    To compare the results after cochlear implantation achieved by monolingual and bilingual deaf children implanted at our Institution, with the aim of understanding if there are any differences between the two groups and if there is a correlation between the outcomes and some patients' variables. The study group was composed by 14 bilingual deaf children and the control group by the same number of monolingual children implanted at our Institution. The control group was obtained by matching to each bilingual child a monolingual one with a similar clinical history regarding age at hearing loss diagnosis, age at first hearing-aids fitting and age at CI procedure. Children received a speech perception and linguistic development evaluation through specific structured tests. The linguistic competence of the patients both in mainstream and native language was determined by the Student Oral Language Observation Matrix (SOLOM). We did not find any statistically significant differences between bilingual and monolingual children in speech perception outcomes. Nevertheless, we obtained different results concerning language skills: bilingual implanted children scored lower at structured language tests, even if the difference was not statistically relevant. Bilingual children scored significantly lower than monolingual ones at the SOLOM scale for linguistic competence. The results reported in the present study show better language skills after cochlear implant in Italian monolingual cases than in bilingual ones. This seems to be related to the condition of bilingualism in Italy, mainly related to immigration, and frequently associated with low socio-economic levels, poor competence in the mainstream language and poor social integration, with a suboptimal exposure to the mainstream language and difficulties in following the rehabilitative program. Copyright © 2017. Published by Elsevier B.V.

  2. Comparative study between the results of effective index based matrix method and characterization of fabricated SU-8 waveguide

    NASA Astrophysics Data System (ADS)

    Samanta, Swagata; Dey, Pradip Kumar; Banerji, Pallab; Ganguly, Pranabendu

    2017-01-01

    A study regarding the validity of effective-index based matrix method (EIMM) for the fabricated SU-8 channel waveguides is reported. The design method is extremely fast compared to other existing numerical techniques, such as, BPM and FDTD. In EIMM, the effective index method was applied in depth direction of the waveguide and the resulted lateral index profile was analyzed by a transfer matrix method. By EIMM one can compute the guided mode propagation constants and mode profiles for each mode for any dimensions of the waveguides. The technique may also be used to design single mode waveguide. SU-8 waveguide fabrication was carried out by continuous-wave direct laser writing process at 375 nm wavelength. The measured propagation losses of these wire waveguides having air and PDMS as superstrates were 0.51 dB/mm and 0.3 dB/mm respectively. The number of guided modes, obtained theoretically as well as experimentally, for air-cladded waveguide was much more than that of PDMS-cladded waveguide. We were able to excite the isolated fundamental mode for the later by precise fiber positioning, and mode image was recorded. The mode profiles, mode indices, and refractive index profiles were extracted from this mode image of the fundamental mode which matched remarkably well with the theoretical predictions.

  3. Psychological stress and health in undergraduate dental students: fifth year outcomes compared with first year baseline results from five European dental schools.

    PubMed

    Gorter, R; Freeman, R; Hammen, S; Murtomaa, H; Blinkhorn, A; Humphris, G

    2008-05-01

    Psychological stress in undergraduate dental students: fifth year outcomes compared with first year baseline results from five European dental schools. To compare the levels of a series of health-related indicators from a cohort of fifth year dental students from five European schools with their first year scores, and to investigate the relationship between these follow-up measures. Burnout was measured using the Maslach Burnout Inventory (MBI), consisting of three scales: Emotional Exhaustion (EE, alpha = 0.90), Depersonalisation (alpha = 0.80) and Personal Accomplishment (alpha = 0.72). Physical health was measured by the Physical Symptoms Questionnaire (alpha = 0.82), psychological distress was measured using the General Health Questionnaire (GHQ, alpha = 0.89) and student stress was captured using seven subscales of the Dental Environment Stress questionnaire (DES, alpha = 0.92). A total of 132 fifth year students responded from five dental schools (Manchester, Belfast, Cork, Helsinki and Amsterdam), a 51% response. Fifth year students showed relatively high mean MBI scores when compared with first year results, especially on EE; 39% could be labelled 'high scorers'; 44% of the students met the criteria for 'cases' on the GHQ. Highest mean scores on the DES were obtained on the subscales: Study Obligations, Patient-Related Aspects and Study Pressure respectively. Between schools interesting differences were detected on all variables. As hypothesised, a clear direct effect of stress on both burnout and physical symptoms was shown. An indirect effect of stress on mental health via burnout was shown. Dental students showed a negative development through the years from first to fifth year with regard to EE and psychological distress. Both burnout constructs related to physical and mental health. It is recommended that dental faculty focus on the importance of prevention and intervention of stress amongst undergraduates.

  4. [Comparative assessment of results in cervical vertigo pharmacotherapy vs physiotherapy treatment].

    PubMed

    Olszewski, Jurek; Repetowski, Marcin; Kuśmierczyk, Krzysztof

    2007-01-01

    The aim of the study was to assess the effectiveness of pharmacotherapy and physiotherapy in cervical vertigo treatment. 80 patients with cervical vertigo (41 women and 39 men), aged 20 to 85, were treated by pharmacotherapy or physiotherapy. There were two groups: group I was treated by pharmacotherapy and group II was treated by physiotherapy and kinesitherapy. The effects of vertigo treatment were assessed by positional nystagmus testing according to Cawthorne and Rosen; cervical nystagmus testing in neck rotation test; by everyday task self-control cards and vertigo staging system according to Silvoniemi (0-4 points). The effects of treatment were assessed before therapy, 6 and 12 weeks after therapy. Patients from group I were treated by Nootropil and Betaserc; group II received magnetic Fidel, laserotherapy, massage and kinesitherapy exercises. The obtained results showed that the most useful methods of cervical vertigo diagnosis were neck rotation test and Rose method. The average number of points (according to Silvoniemi scale) on the basis of ten everyday activities, was lower after 6 weeks of treatment than before the treatment and the lowest after 12 weeks of treatment. The difference was higher in group II than in group I. Patients treated by physiotherapy (group II) performed better in everyday activities than the patients treated by pharmacotherapy (group I). Cervical vertigo treatment by physiotherapy is cheap and underestimated method.

  5. Spectral inversion of frequency-domain IP data obtained in Haenam, South Korea

    NASA Astrophysics Data System (ADS)

    Kim, B.; Nam, M. J.; Son, J. S.

    2017-12-01

    Spectral induced polarization (SIP) method using a range of source frequencies have been performed for not only exploring minerals resources, but also engineering or environmental application. SIP interpretation first makes inversion of individual frequency data to obtain complex resistivity structures, which will further analyzed employing Cole-Cole model to explain the frequency-dependent characteristics. However, due to the difficulty in fitting Cole-Cole model, there is a movement to interpret complex resistivity structure inverted only from a single frequency data: that is so-called "complex resistivity survey". Further, simultaneous inversion of multi-frequency SIP data, rather than making a single frequency SIP data, has been studied to improve ambiguity and artefacts of independent single frequency inversion in obtaining a complex resistivity structure, even though the dispersion characteristics of complex resistivity with respect to source frequency. Employing the simultaneous inversion method, this study makes inversion of field SIP data obtained over epithermal mineralized area, Haenam, in the southernmost tip of South Korea. The area has a polarizable structure because of extensive hydrothermal alteration, gold-silver deposits. After the inversion, we compare between inversion results considering multi-frequency data and single frequency data set to evaluate the performance of simultaneous inversion of multi-frequency SIP data.

  6. Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes

    NASA Astrophysics Data System (ADS)

    Ali, Saima; Hannula, Simo-Pekka

    2017-05-01

    Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO4) solution (Process 1), and ethylene glycol (EG) mixture with HClO4 and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted to nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25-600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m2 g-1 is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes.

  7. Continuous H/V spectral ratio analysis of ambient noise: a necessity to understand microzonation results obtained by mobile stations

    NASA Astrophysics Data System (ADS)

    Van Noten, Koen; Lecocq, Thomas

    2016-04-01

    Estimating the resonance frequency (f0) and amplification factor of unconsolidated sediments by H/V spectral ratio (HVSR) analysis of seismic ambient noise has been widely used since Nakamura's proposal in 1989. To measure f0 properly, Nakamura suggested to perform microzonation surveys at night when the artificial microtremor is small and does not fully disrupt the ambient seismic noise. As nightly fieldwork is not always a reasonable demand, we propose an alternative workflow of Nakamura's technique to improve the quality of HVSR results obtained by ambient noise measurements of mobile stations during the day. This new workflow includes the automated H/V calculation of continuous seismic data of a stationary or permanent station installed near the microzonation site for as long as the survey lasts in order to control the error in the HVSR analysis obtained by the mobile stations. In this presentation, we apply this workflow on one year of seismic data at two different case studies; i.e. a rural site with a shallow bedrock depth of 30 m and an urban site (Brussels, capital of Belgium, bedrock depth of 110 m) where human activity is continuous 24h/day. By means of an automated python script, the fundamental peak frequency and the H/V amplitude are automatically picked from H/V spectra that are calculated from 50% overlapping, 30 minute windows during the whole year. Afterwards, the f0 and amplitude picks are averaged per hour/per day for the whole year. In both case studies, the H/V amplitude and the fundamental frequencies range considerable, up to ˜15% difference between the daily and nightly measurements. As bedrock depth is known from boreholes at both sites, we concluded that the nightly picked f0 is the true one. Our results thus suggest that changes in the determined f0 and H/V amplitude are dominantly caused by the human behaviour which is stored in the ambient seismic noise (e.g. later onset of traffic in a weekend, quiet Sundays, differences between

  8. Discrepancy between results and abstract conclusions in industry- vs nonindustry-funded studies comparing topical prostaglandins.

    PubMed

    Alasbali, Tariq; Smith, Michael; Geffen, Noa; Trope, Graham E; Flanagan, John G; Jin, Yaping; Buys, Yvonne M

    2009-01-01

    To investigate the relationship between industry- vs nonindustry-funded publications comparing the efficacy of topical prostaglandin analogs by evaluating the correspondence between the statistical significance of the publication's main outcome measure and its abstract conclusions. Retrospective, observational cohort study. English publications comparing the ocular hypotensive efficacy between any or all of latanoprost, travoprost, and bimatoprost were searched from the MEDLINE database. Each article was reviewed by three independent observers and was evaluated for source of funding, study quality, statistically significant main outcome measure, correspondence between results of main outcome measure and abstract conclusion, number of intraocular pressure outcomes compared, and journal impact factor. Funding was determined by published disclosure or, in cases of no documented disclosure, the corresponding author was contacted directly to confirm industry funding. Discrepancies were resolved by consensus. The main outcome measure was correspondence between abstract conclusion and reported statistical significance of the publications' main outcome measure. Thirty-nine publications were included, of which 29 were industry funded and 10 were nonindustry funded. The published abstract conclusion was not consistent with the results of the main outcome measure in 18 (62%) of 29 of the industry-funded studies compared with zero (0%) of 10 of the nonindustry-funded studies (P = .0006). Twenty-six (90%) of the industry-funded studies had proindustry abstract conclusions. Twenty-four percent of the industry-funded publications had a statistically significant main outcome measure; however, 90% of the industry-funded studies had proindustry abstract conclusions. Both readers and reviewers should scrutinize publications carefully to ensure that data support the authors' conclusions.

  9. Immediate toe-to-hand transfer in acute hand injuries: overall results, compared with results for elective cases.

    PubMed

    Woo, Sang-Hyun; Kim, Joo-Sung; Seul, Jung-Hyun

    2004-03-01

    In the past 5 years, 25 mutilated digits were reconstructed with immediate toe-to-hand transfers after acute hand injuries, for 21 patients. The overall results of the immediate toe-to-hand transfers were evaluated and compared with the results of 65 elective procedures performed during the same period by the same surgeon. There were 15 cases of great toe-to-hand transfer for thumb reconstruction, two cases of second toe transfer for index finger reconstruction, and four cases of simultaneous two-toe transfer for reconstruction of multiple-digit amputations. Two cases (two of 25 cases, 8 percent) were successfully salvaged with emergency reexploration. The incidences of emergency reexploration and postoperative infection were not significantly different from those for elective toe-to-hand transfer cases. The duration of industrial insurance coverage was much shorter than for elective cases, averaging 225 days (p < 0.001). Approximately 44 percent of the patients maintained their original jobs after immediate toe-to-hand transfer. The subjective satisfaction self-assessment scores of aesthetic appearance and function for the newly reconstructed thumb averaged 80 and 88 (of a total score of 100), respectively. Although satisfaction was lower than for elective reconstruction (p < 0.001), it was higher than for reconstruction of other digits. The donor-site appearance after great toe harvesting was mostly unsatisfactory. Immediate toe-to-hand transfer provides many advantages over the elective procedure in acute hand injuries, including single-stage reconstruction, shortened convalescence, early return to work, and socioeconomic efficiency. Because there were no significant differences in the success rates, frequencies of complications, or ultimate functional results, immediate toe-to-hand transfer is a safe and reliable procedure that is indicated for specific cases of acute digital amputation.

  10. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States.

    PubMed

    Othman, Noordin; Vitry, Agnes I; Roughead, Elizabeth E

    2010-05-29

    Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%). In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P < 0.001). However, the unambiguous claims were supported by more references than other claims (80%). Most evidence was obtained from at least one randomized controlled trial, a systematic review or meta-analysis (Australia, 84%, Malaysia, 81%, US, 76%) with journal articles being the most commonly cited references in all countries. Data on file were significantly more likely to be cited in the US (17%) than in Australia (2%) and Malaysia (4%) (P < 0.001). Advertisements that provided quantitative information reported risk results exclusively as a relative risk reduction. The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and independently reviewed in the US compared

  11. Results from CrIS-ATMS Obtained Using the AIRS Science Team Retrieval Methodology

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis C.; Iredell, Lena

    2013-01-01

    AIRS was launched on EOS Aqua in May 2002, together with AMSU-A and HSB (which subsequently failed early in the mission), to form a next generation polar orbiting infrared and microwave atmospheric sounding system. AIRS/AMSU had two primary objectives. The first objective was to provide real-time data products available for use by the operational Numerical Weather Prediction Centers in a data assimilation mode to improve the skill of their subsequent forecasts. The second objective was to provide accurate unbiased sounding products with good spatial coverage that are used to generate stable multi-year climate data sets to study the earth's interannual variability, climate processes, and possibly long-term trends. AIRS/AMSU data for all time periods are now being processed using the state of the art AIRS Science Team Version-6 retrieval methodology. The Suomi-NPP mission was launched in October 2011 as part of a sequence of Low Earth Orbiting satellite missions under the "Joint Polar Satellite System" (JPSS). NPP carries CrIS and ATMS, which are advanced infra-red and microwave atmospheric sounders that were designed as follow-ons to the AIRS and AMSU instruments. The main objective of this work is to assess whether CrIS/ATMS will be an adequate replacement for AIRS/AMSU from the perspective of the generation of accurate and consistent long term climate data records, or if improved instruments should be developed for future flight. It is critical for CrIS/ATMS to be processed using an algorithm similar to, or at least comparable to, AIRS Version-6 before such an assessment can be made. We have been conducting research to optimize products derived from CrIS/ATMS observations using a scientific approach analogous to the AIRS Version-6 retrieval algorithm. Our latest research uses Version-5.70 of the CrIS/ATMS retrieval algorithm, which is otherwise analogous to AIRS Version-6, but does not yet contain the benefit of use of a Neural-Net first guess start-up system

  12. Results of the 1978 NACUBO Comparative Performance Study and Investment Questionnaire.

    ERIC Educational Resources Information Center

    Dresner, Bruce M.

    Information from the 1978 Comparative Performance Study and investment questionnaire conducted by the National Association of College and University Business Officers is presented. One hundred forty-four institutions provided information about 164 investment pools. The Comparative Performance Study provides participating institutions with…

  13. Mechanical behaviour of pressed and sintered titanium alloys obtained from master alloy addition powders.

    PubMed

    Bolzoni, L; Esteban, P G; Ruiz-Navas, E M; Gordo, E

    2012-11-01

    The fabrication of the workhorse Ti-6Al-4V alloy and of the Ti-3Al-2.5V alloy was studied considering the master alloy addition variant of the blending elemental approach conventionally used for titanium powder metallurgy. The powders were characterised by means thermal analysis and X-ray diffraction and shaped by means of uniaxial pressing. The microstructural evolution with the sintering temperature (900-1400 °C) was evaluated by SEM and EDS was used to study the composition. XRD patterns as well as the density by Archimedes method were also obtained. The results indicate that master alloy addition is a suitable way to fabricate well developed titanium alloy but also to produce alloy with the desired composition, not available commercially. Density of 4.3 g/cm³ can be obtained where a temperature higher than 1200 °C is needed for the complete diffusion of the alloying elements. Flexural properties comparable to those specified for wrought Ti-6Al-4V medical devices are, generally, obtained. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Development of a Method to Obtain More Accurate General and Oral Health Related Information Retrospectively

    PubMed Central

    A, Golkari; A, Sabokseir; D, Blane; A, Sheiham; RG, Watt

    2017-01-01

    Statement of Problem: Early childhood is a crucial period of life as it affects one’s future health. However, precise data on adverse events during this period is usually hard to access or collect, especially in developing countries. Objectives: This paper first reviews the existing methods for retrospective data collection in health and social sciences, and then introduces a new method/tool for obtaining more accurate general and oral health related information from early childhood retrospectively. Materials and Methods: The Early Childhood Events Life-Grid (ECEL) was developed to collect information on the type and time of health-related adverse events during the early years of life, by questioning the parents. The validity of ECEL and the accuracy of information obtained by this method were assessed in a pilot study and in a main study of 30 parents of 8 to 11 year old children from Shiraz (Iran). Responses obtained from parents using the final ECEL were compared with the recorded health insurance documents. Results: There was an almost perfect agreement between the health insurance and ECEL data sets (Kappa value=0.95 and p < 0.001). Interviewees remembered the important events more accurately (100% exact timing match in case of hospitalization). Conclusions: The Early Childhood Events Life-Grid method proved to be highly accurate when compared with recorded medical documents. PMID:28959773

  15. Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy.

    PubMed

    Jha, Ashish Kumar A; Zade, Anand A; Rangarajan, Venkatesh; Purandare, Nilendu; Shah, Sneha A; Agrawal, Archi; Kulkarni, Suyash S; Shetty, Nitin

    2012-05-01

    (99m)Tc macroaggregate albumin (MAA) scintigraphy is routinely used to estimate the hepatopulmonary shunt (HPS) of (90)Y microspheres because of their comparable average particle sizes (20-30 µm). However, the MAA particle size can vary from 10 to 90 µm. Therefore, HPS computed from (99m)Tc MAA scintigraphy may not accurately represent the HPS of (90)Y microspheres. In view of this, the present study was undertaken to investigate the accuracy of (99m)Tc MAA scintigraphy in estimating the HPS of (90)Y microspheres. Nineteen sessions of transarterial radioembolization using (90)Y therasphere were carried out in 17 patients for hepatic malignancies (both primary and secondary). For each session of therapy, a pretherapeutic (99m)Tc MAA scintigraphy and post-therapeutic (90)Y Bremsstrahlung scintigraphy were performed. The HPSs obtained from these images were compared. The mean HPS fractions calculated from the pretherapeutic (99m)Tc MAA study and the post-therapeutic (90)Y Bremsstrahlung images were 4.77 ± 2.81 and 4.52 ± 2.5%, respectively. The coefficient of correlation (r) was 0.96. (99m)Tc MAA scintigraphy accurately predicts the HPS of (90)Y microspheres.

  16. Results of the 1980 NACUBO Comparative Performance Study and Investment Questionnaire.

    ERIC Educational Resources Information Center

    Dresner, Bruce M.

    The purpose of the annual National Association of College and University Business Officers' (NACUBO) Comparative Performance Study is to aid administrators in evaluating the performance of their investment pools. The 1980 study contains two parts: (1) comparative performance information and related investment performance statistics; and (2) other…

  17. Vibrational properties of gold nanoparticles obtained by green synthesis

    NASA Astrophysics Data System (ADS)

    Alvarez, Ramón A. B.; Cortez-Valadez, M.; Bueno, L. Oscar Neira; Britto Hurtado, R.; Rocha-Rocha, O.; Delgado-Beleño, Y.; Martinez-Nuñez, C. E.; Serrano-Corrales, Luis Ivan; Arizpe-Chávez, H.; Flores-Acosta, M.

    2016-10-01

    This study reports the synthesis and characterization of gold nanoparticles through an ecological method to obtain nanostructures from the extract of the plant Opuntia ficus-indica. Colloidal nanoparticles show sizes that vary between 10-20 nm, and present various geometric morphologies. The samples were characterized through optical absorption, Raman Spectroscopy and Transmission Electron Microscopy (TEM). Additionally, low energy metallic clusters of Aun (n=2-20 atoms) were modeled by computational quantum chemistry. The theoretical results were obtained with Density Functional Theory (DFT). The predicted results of Au clusters show a tendency and are correlated with the experimental results concerning the optical absorption bands and Raman spectroscopy in gold nanoparticles.

  18. Obtaining Parts

    Science.gov Websites

    The Cosmic Connection Parts for the Berkeley Detector Suppliers: Scintillator Eljen Technology 1 obtain the components needed to build the Berkeley Detector. These companies have helped previous the last update. He estimates that the cost to build a detector varies from $1500 to $2700 depending

  19. Band-gap engineering and comparative investigation of Ti2Nb10O29 photocatalysts obtained by Various synthetic routes

    NASA Astrophysics Data System (ADS)

    Xie, Meiling; Zhu, Hekai; Fang, Minghao; Huang, Zhaohui; Liu, Yan'gai; Wu, Xiaowen

    2018-03-01

    Ti2Nb10O29 photocatalysts were successfully synthesized by three different methods. Ti2Nb10O29 fabricated by the solvothermal method (ST-TNO) exhibited unique microspheres compared to the larger irregular particles observed for the samples annealed in air (Air-TNO) and Ar (Ar-TNO). X-ray Photoelectron Spectroscopy (XPS) results revealed that a partial reduction process from Ti4+ into Ti3+ occurs in Ar-TNO, because of the introduction of oxygen defects. Ar-TNO exhibited visible-light absorption with a band gap of 2.85 eV, while the absorption edges of Air-TNO and ST-TNO were approximately 400 nm. Under UV light irradiation (λ < 420 nm), Ar-TNO exhibited a photocatalytic activity 2.1 times greater than that of Air-TNO, corresponding to the highest activity. The results indicated that the preparation method is crucial for determining the band gap and photocatalytic activity of semiconductors. Moreover, the novel semiconductor photocatalyst can be further applied for constructing the heterojunction and designing the band structure.

  20. Students' Progression in Monitoring Anomalous Results Obtained in Inquiry-Based Laboratory Tasks

    NASA Astrophysics Data System (ADS)

    Crujeiras-Pérez, Beatriz; Jiménez-Aleixandre, Maria Pilar

    2017-07-01

    This paper examines students' engagement in monitoring anomalous results across a 2-year longitudinal study with 9th and 10th graders (14-15 and 15-16 years of age). The context is a set of five inquiry-based laboratory tasks, requiring students to plan and carry out investigations. The study seeks to examine students' interpretation of data, in particular anomalous results generated by them during the process of solving the tasks, and their ability to monitor them. Data collected include video and audio recordings as well as students' written products. For the analysis, two rubrics were developed drawing on Chinn and Brewer (Cognition and Instruction, 19, 323-393, 2001) and Hmelo-Silver et al. (Science Education, 86, 219-243, 2002). The findings point to a pattern of progress in students' responses across the 2 years: (a) responses revealing a low capacity of monitoring due to not recognizing the data as anomalous or recognizing it as anomalous but being unable to explain their causes are more frequent in the first tasks and (b) responses revealing an improved capacity of monitoring are more frequent in the last tasks. The factors influencing students' regulation of their performances, as the requirement of planning, and specific scaffolding based on activity theory are discussed.

  1. Investigation of Properties of Nanocomposite Polyimide Samples Obtained by Fused Deposition Modeling

    NASA Astrophysics Data System (ADS)

    Polyakov, I. V.; Vaganov, G. V.; Yudin, V. E.; Ivan'kova, E. M.; Popova, E. N.; Elokhovskii, V. Yu.

    2018-03-01

    Nanomodified polyimide samples were obtained by fused deposition modeling (FDM) using an experimental setup for 3D printing of highly heat-resistant plastics. The mechanical properties and structure of these samples were studied by viscosimetry, differential scanning calorimetry, and scanning electron microscopy. A comparative estimation of the mechanical properties of laboratory samples obtained from a nanocomposite based on heat-resistant polyetherimide by FDM and injection molding is presented.

  2. [Sensitivity to change of questionnaires measuring subjective health--results of a prospective comparative study].

    PubMed

    Igl, W; Zwingmann, C; Faller, H

    2006-08-01

    Questionnaires measuring patients' subjective health or health-related quality of life are indispensable tools for the evaluation of effects revealed by intervention studies in the field of medical rehabilitation. These patient-reported outcomes should appropriately reflect change over time. Unfortunately, "sensitivity to change" has so far not been adequately examined for German health-related quality of life questionnaires, especially not in a comparative way. Therefore, indices of sensitivity to change for three widespread generic assessment tools have been determined: IRES-3, SF-36, scales of the SCL-90-R. A prospective comparative study was conducted in n = 1145 inpatients with orthopaedic/rheumatologic and cardiac diseases from 16 rehabilitation clinics. All patients received usual care. Their subjective health-status was assessed at two to four weeks before admission (t0), admission (t1), discharge (t2), and three months after discharge (t3). At each time point, they completed the IRES-3, SF-36, and relevant scales of the SCL-90-R. For the time interval t1-t2, Guyatt's responsiveness index (GRI) was calculated and compared across scales and instruments. Virtually all GRI coefficients for scales and aggregated scores, respectively, reached statistical significance. With respect to the GRI distributions of the diagnostic groups, most coefficients were located in a middle to upper range. While the results for the scales do not clearly indicate which assessment instrument should be preferred, GRI coefficients for higher aggregated scores suggest the IRES-3 to be most sensitive to change. These results can be helpful in selecting a health-related quality of life instrument or certain subscales for evaluation studies in the field of medical rehabilitation.

  3. Results of a simulator test comparing two display concepts for piloted flight-path-angle control

    NASA Technical Reports Server (NTRS)

    Kelley, W. W.

    1978-01-01

    Results of a simulator experiment which was conducted in order to compare pilot gamma-control performance using two display formats are reported. Pilots flew a variable flight path angle tracking task in the landing configuration. Pilot and airplane performance parameters were recorded and pilot comments noted for each case.

  4. In Vivo Efficacy of Gum Obtained Pistacia Atlantica in Experimental Treatment of Cutaneous Leishmaniasis

    PubMed Central

    Taran, M; Mohebali, M; Esmaeli, J

    2010-01-01

    Background: Recent circumstantial evidences are suggesting that an increasing number of Iranian patients with cutaneous leishmaniasis are unresponsive to meglumine antimoniate (Glucantime®). Pistacia atlantica is native plant in Iran (central, western, and eastern regions). Gum obtained Pistacia atlantica has been reported to possess considerable in vitro antimicrobial activity. In this study, we aimed to investigate antileishmanial activity of P. atlantica. Methods Male BALB/c mice were inoculated subcutaneously 2×106 L. major Promastigotes (MHROM/IR/75/ER) at the base of tail in 2007. Mice were randomly divided into 3 groups. in group 1 Glucantime® was administered to the BALB/c mice in regimen of 60 mg per kg of body weight for 28 days by intraperitoneal injections per day, in group 2 the gum of P. atlantica var. Kurdica were tested by rubbing of local lesions for 28 days, group 3 infected but non-treated. Comparisons of treated groups and untreated group were done by two-way analysis of variance (ANOVA) Results Topically rubbing administration of gum obtained P. atlantica var. kurdica daily for 28 days like Glucantime® decreased skin lesion size in the BALB/c mice infected with L. major compared with that in the control (P< 0.01). Treatment BALB/c mice with gum obtained P. atlantica var. kurdica and Glucantime® causes decrease number of parasitologicaly positive mice (P< 0.05). Conclusion Our results show that gum obtained P. atlantica var. kurdica can be used for controlling cutaneous leishmaniasis caused by L. major and inhibiting development of cutaneous leishmaniasis lesions. PMID:23112988

  5. The self-adjusting file instrumentation results in less debris extrusion apically when compared to WaveOne and ProTaper NEXT

    PubMed Central

    Pawar, Ajinkya M.; Pawar, Mansing G.; Metzger, Zvi; Kokate, Sharad R.

    2015-01-01

    Aim: The present ex vivo study aimed to evaluate the debris extrusion after instrumenting the root canals by three different files systems. Materials and Methods: Sixty extracted human mandibular premolars with single canals were selected and randomly divided into three groups (n = 20) for instrumentation with three different files. Group 1: WaveOne (primary) single reciprocating file (WO; Dentsply Maillefer, Ballaigues, Switzerland) (25/08), Group 2: Self-adjusting file (SAF; ReDent-Nova, Ra’anana, Israel) (1.5 mm), and Group 3: ProTaper NEXT X1 and X2 (PTN; Dentsply Tulsa Dental, Tulsa, OK) (25/06). Debris extruding by instrumentation were collected into pre-weighed Eppendorf tubes. These tubes were then stored in an incubator at 70°C for 5 days. The tubes were then weighed to obtain the final weight, with the extruded debris. Statistical analysis for the debris extruded apically was performed using one-way analysis of variance and post hoc Tukey's test. Results: The statistical analysis showed a significant difference between all the three groups tested (P < 0.01). The following post hoc Tukey's test confirmed that Group 2 (SAF) exhibited significantly least (P < 0.01) debris extrusion between the three groups tested. Conclusions: The SAF resulted in significantly less extrusion of debris when compared to reciprocating WO and rotary PTN. PMID:25829683

  6. Cytotoxic, anti-cancer, and anti-microbial effects of different extracts obtained from Artemisia rupestris.

    PubMed

    Nokerbek, Shamshabanu; Sakipova, Zuriyadda; Chalupová, Marta; Nejezchlebová, Marcela; Hošek, Jan

    2017-01-01

    Artemisia rupestris is a part of traditional Kazakh folk medicine. Extracts obtained from this plant are used to treat various diseases, including cancer. This study evaluates the anti-microbial, cytotoxic, and anti-cancer effects of different extracts of the plant. Different extraction techniques were used and the resultant activities were compared. Extracts of A. rupestris were prepared from the flowers plus the leaves and from the stems. The antimicrobial activity against Candida albicans and Staphylococcus aureus was quantified. Cell lines L1210 and THP-1 were used to evaluate the cytotoxic potential of these extracts in vitro. The anti-cancer effect was tested using L1210-induced tumorgenesis in mouse model. The aqueous extract of stems was the most active against C. albicans, whereas the methanolic extract of flowers plus leaves especially inhibited the growth of S. aureus. The aqueous extracts were found to be non-cytotoxic for both cell lines, whereas the lipophilic extracts showed cytotoxic effects. The extract obtained from flowers plus leaves was more cytotoxic than that from stems. The tested extracts showed no anti-cancer potential. The results obtained testify to the relatively safe consumption of aqueous extracts of A. rupestris, but lipophilic extracts showed toxic effects and their consumption should be considered more carefully.Key words: L1210 cell line THP-1 cell line microwave-assisted extraction ultrasonic-assisted extraction Candida albicans Staphylococcus aureus.

  7. Significant results from the HCMM program

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The major objectives of the HCMM program for applications in geology, agriculture, water studies, and the effects of climate on metropolitan areas are summarized. Results obtained by Principal Investigators in each of these disciplines are presented, discussed, and supported with figures and tables. In order to compare the types of observations and applications that can be derived from HCMM data with some remote sensing standard or framework for each discipline, the principal results already achieved with the LANDSAT system are included.

  8. Results from CrIS/ATMS Obtained Using an "AIRS Version-6 Like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena

    2015-01-01

    A main objective of AIRS/AMSU on EOS is to provide accurate sounding products that are used to generate climate data sets. Suomi NPP carries CrIS/ATMS that were designed as follow-ons to AIRS/AMSU. Our objective is to generate a long term climate data set of products derived from CrIS/ATMS to serve as a continuation of the AIRS/AMSU products. We have modified an improved version of the operational AIRS Version-6 retrieval algorithm for use with CrIS/ATMS. CrIS/ATMS products are of very good quality, and are comparable to, and consistent with, those of AIRS.

  9. First archeointensity results from Portuguese potteries (1550-1750 AD)

    NASA Astrophysics Data System (ADS)

    Hartmann, Gelvam A.; Trindade, Ricardo I. F.; Goguitchaichvili, Avto; Etchevarne, Carlos; Morales, Juan; Afonso, Marisa C.

    2009-01-01

    Geomagnetic field variations at archeomagnetic timescales can be obtained from well-dated heated structures and archeological potsherds. Here, we present the first archeointensity results obtained on Portuguese ceramics (1550 to 1750 AD) collected at Brazilian archeological sites. The results are compared to those obtained from Western Europe and currently available geomagnetic field models. Continuous thermomagnetic and IRM acquisitions curves indicate that Ti-poor titanomagnetite is responsible for the remanence in these ceramic fragments. Five fragments (24 samples) out of twelve analyzed yielded reliable intensity estimates. The row archeointensity data were corrected for TRM anisotropy and cooling rate effect. The mean dipole moments are obtained for three different age intervals: 1550±30 AD, 1600±30 AD and 1750±50 AD. Mean intensities vary from 37.9±4.2 μT to 54.8±7.6 μT in agreement with the previously reported data for 1550 AD and 1750 AD. Relatively weaker, but still highly dispersed, values were obtained for 1600 AD ceramics.

  10. Results of a Study Investigating the Plant Uptake of Explosive Residues From Compost of Explosives-Contaminated Soil Obtained from the Umatilla Army Depot Activity

    DTIC Science & Technology

    1998-11-01

    Avoid contact with samples. Be aware of broken containers, corrosives, irritants, biohazards, flammability, pyrophoricity , reactivity, radioactivity...Revision RO 9/23/97 Page 3 NOj-N by Flow Injection Analysis 6.2.2.2 Low results may be obtained for samples that contain high concentrations of iron ...however, for analytes such as iron that may be found at high concentration, a more appropriate test would be to use a concentration near the upper

  11. Gonadal steroidogenesis in vitro from juvenile alligators obtained from contaminated or control lakes.

    PubMed Central

    Guillette, L J; Gross, T S; Gross, D A; Rooney, A A; Percival, H F

    1995-01-01

    The ubiquitous distribution of many contaminants and the nonlethal, multigenerational effects of such contaminants on reproductive, endocrine, and immune systems have led to concerns that wildlife worldwide are affected. Although the causal agents and effects are known for some species, the underlying physiological mechanisms associated with contaminant-induced reproductive modifications are still poorly understood and require extensive research. We describe a study examining the steroidogenic activity of gonads removed from juvenile alligators (Alligator mississippiensis) obtained from contaminated or control lakes in central Florida. Synthesis of estradiol-17 beta (E2) was significantly different when ovaries from the contaminated and control lakes were compared in vitro. Additionally, testes from males obtained from the contaminated lake. Lake Apopka, synthesized significantly higher concentrations of E2 when compared to testes obtained from control males. In contrast, testosterone (T) synthesis from all testes examined in this study displayed a normal pattern and produced concentrations greater than that observed from ovaries obtained from either lake. Interestingly, the pattern of gonadal steroidogenesis differs from previously reported plasma concentrations of these hormones obtained from the same individuals. We suggest that the differences between the in vivo and in vitro patterns are due to modifications in the hepatic degradation of plasma sex steroid hormones. PMID:7556021

  12. Comparison of five pretreatments for the production of fermentable sugars obtained from Pinus pseudostrobus L. wood

    PubMed Central

    Farías-Sánchez, Juan Carlos; López-Miranda, Javier; Castro-Montoya, Agustín Jaime; Saucedo-Luna, Jaime; Carrillo-Parra, Artemio; López-Albarrán, Pablo; Pineda-Pimentel, María Guadalupe; Rutiaga-Quiñones, José Guadalupe

    2015-01-01

    To benefit from the use of a waste product such as pine sawdust from a sawmill in Michoacán, Mexico, five different pretreatments for the production of reducing sugars by enzymatic hydrolysis were evaluated (sodium hydroxide, sulfuric acid, steam explosion, organosolv and combined method nitric acid / sodium hydroxide). The main finding of the study was that the pretreatment with 6 % HNO3 and 1 % NaOH led to better yields than those obtained with sodium hydroxide, dilute sulfuric acid, steam explosion, and organosolv pretreatments. Also, HNO3 yields were maximized by the factorial method. With those results the maxima concentration of reducing sugar found was 97.83 ± 1.59, obtained after pretreatment with 7.5 % HNO3 at 120 °C for 30 minutes; followed by 1 % of NaOH at 90 °C for 30 minutes at pH 4.5 for 168 hours with a load enzyme of 25 FPU/g of total carbohydrates. Comparing the results obtained by the authors with those reported in the literature, the combined method was found to be suitable for use in the exploitation of sawdust. PMID:26535036

  13. Comparison of five pretreatments for the production of fermentable sugars obtained from Pinus pseudostrobus L. wood.

    PubMed

    Farías-Sánchez, Juan Carlos; López-Miranda, Javier; Castro-Montoya, Agustín Jaime; Saucedo-Luna, Jaime; Carrillo-Parra, Artemio; López-Albarrán, Pablo; Pineda-Pimentel, María Guadalupe; Rutiaga-Quiñones, José Guadalupe

    2015-01-01

    To benefit from the use of a waste product such as pine sawdust from a sawmill in Michoacán, Mexico, five different pretreatments for the production of reducing sugars by enzymatic hydrolysis were evaluated (sodium hydroxide, sulfuric acid, steam explosion, organosolv and combined method nitric acid / sodium hydroxide). The main finding of the study was that the pretreatment with 6 % HNO3 and 1 % NaOH led to better yields than those obtained with sodium hydroxide, dilute sulfuric acid, steam explosion, and organosolv pretreatments. Also, HNO3 yields were maximized by the factorial method. With those results the maxima concentration of reducing sugar found was 97.83 ± 1.59, obtained after pretreatment with 7.5 % HNO3 at 120 °C for 30 minutes; followed by 1 % of NaOH at 90 °C for 30 minutes at pH 4.5 for 168 hours with a load enzyme of 25 FPU/g of total carbohydrates. Comparing the results obtained by the authors with those reported in the literature, the combined method was found to be suitable for use in the exploitation of sawdust.

  14. Comparison of results of fluconazole disk diffusion testing for Candida species with results from a central reference laboratory in the ARTEMIS global antifungal surveillance program.

    PubMed

    Pfaller, M A; Hazen, K C; Messer, S A; Boyken, L; Tendolkar, S; Hollis, R J; Diekema, D J

    2004-08-01

    The accuracy of antifungal susceptibility tests is important for accurate resistance surveillance and for the clinical management of patients with serious infections. Our main objective was to compare the results of fluconazole disk diffusion testing of Candida spp. performed by ARTEMIS participating centers with disk diffusion and MIC results obtained by the central reference laboratory. A total of 2,949 isolates of Candida spp. were tested by NCCLS disk diffusion and reference broth microdilution methods in the central reference laboratory. These results were compared to the results of disk diffusion testing performed in the 54 participating centers. All tests were performed and interpreted following NCCLS recommendations. Overall categorical agreement between participant disk diffusion test results and reference laboratory MIC results was 87.4%, with 0.2% very major errors (VME) and 3.3% major errors (ME). The categorical agreement between the disk diffusion test results obtained in the reference laboratory with the MIC test results was similar: 92.8%. Likewise, good agreement was observed between participant disk diffusion test results and reference laboratory disk diffusion test results: 90.4%, 0.4% VME, and 3.4% ME. The disk diffusion test was especially reliable in detecting those isolates of Candida spp. that were characterized as resistant by reference MIC testing. External quality assurance data obtained by surveillance programs such as the ARTEMIS Global Antifungal Surveillance Program ensure the generation of useful surveillance data and result in the continued improvement of antifungal susceptibility testing practices.

  15. Quality of claims, references and the presentation of risk results in medical journal advertising: a comparative study in Australia, Malaysia and the United States

    PubMed Central

    2010-01-01

    Background Journal advertising is used by pharmaceutical companies to disseminate medicine information to doctors. The quality of claims, references and the presentation of risk results in Australia and the US has been questioned in several studies. No recent evidence is available on the quality of claims, references and the presentation of risk results in journal advertising in Australia and the US and no Malaysian data have been published. The aim of this study was to compare the quality of claims, references and the presentation of risk results in journal advertising in these three countries. Methods A consecutive sample of 85 unique advertisements from each country was selected from journal advertising published between January 2004 to December 2006. Claims, references and the presentation of risk results in medical journal advertising were compared between the three countries. Results Less than one-third of the claims were unambiguous claims (Australia, 30%, Malaysia 17%, US, 23%). In Malaysia significantly less unambiguous claims were provided than in Australia and the US (P < 0.001). However, the unambiguous claims were supported by more references than other claims (80%). Most evidence was obtained from at least one randomized controlled trial, a systematic review or meta-analysis (Australia, 84%, Malaysia, 81%, US, 76%) with journal articles being the most commonly cited references in all countries. Data on file were significantly more likely to be cited in the US (17%) than in Australia (2%) and Malaysia (4%) (P < 0.001). Advertisements that provided quantitative information reported risk results exclusively as a relative risk reduction Conclusions The majority of claims were vague suggesting poor quality of claims in journal advertising in these three countries. Evidence from a randomized controlled trial, systematic review or meta- analysis was commonly cited to support claims. However, the more frequent use of data that have not been published and

  16. Magnetic resonance imaging screening results compared with explantation results in poly implant prothèse silicone breast implants, recalled from the European market in 2010.

    PubMed

    Maijers, Maria C; Niessen, Francisus B; Veldhuizen, Jacob F H; Ritt, Marco J P F; Manoliu, Radu A

    2014-02-01

    In a prospective cohort study, the authors followed 112 women whose Poly Implant Prothèse silicone breast implants were recalled. Magnetic resonance imaging results and clinical consequences were previously published. The authors compared magnetic resonance imaging screening with explantation results to study the diagnostic value of magnetic resonance imaging in this unique unselected and nonbiased group. women with 224 proven Poly Implant Prothèse implants after a mean implantation time of 10 years were enrolled in 2011. All women underwent magnetic resonance imaging screening and were offered explantation. The explantation details of 107 women could be compared with magnetic resonance imaging results. Of 107 women, 29 (27 percent) had at least one ruptured implant at explantation, and 44 of 214 explanted implants (21 percent) were ruptured. The magnetic resonance imaging results correctly diagnosed 154 intact and 35 ruptured implants. Sensitivity and specificity were 80 percent and 91 percent, respectively. The positive predictive value was 69 percent, and the negative predictive value was 95 percent. The accuracy of magnetic resonance imaging is comparable to previously published data from other manufacturers of modern silicone implants but lower than that of some recent validation studies in selected symptomatic women. The authors believe that this study is representative of common daily practice as they followed normal day-to-day magnetic resonance imaging protocol without using multiple independent readers. The authors hope that this study will contribute to the ongoing discussion to screen asymptomatic women with modern silicone breast implants. Diagnostic, II.

  17. Comparing Medline citations using modified N-grams

    PubMed Central

    Nawab, Rao Muhammad Adeel; Stevenson, Mark; Clough, Paul

    2014-01-01

    Objective We aim to identify duplicate pairs of Medline citations, particularly when the documents are not identical but contain similar information. Materials and methods Duplicate pairs of citations are identified by comparing word n-grams in pairs of documents. N-grams are modified using two approaches which take account of the fact that the document may have been altered. These are: (1) deletion, an item in the n-gram is removed; and (2) substitution, an item in the n-gram is substituted with a similar term obtained from the Unified Medical Language System  Metathesaurus. N-grams are also weighted using a score derived from a language model. Evaluation is carried out using a set of 520 Medline citation pairs, including a set of 260 manually verified duplicate pairs obtained from the Deja Vu database. Results The approach accurately detects duplicate Medline document pairs with an F1 measure score of 0.99. Allowing for word deletions and substitution improves performance. The best results are obtained by combining scores for n-grams of length 1–5 words. Discussion Results show that the detection of duplicate Medline citations can be improved by modifying n-grams and that high performance can also be obtained using only unigrams (F1=0.959), particularly when allowing for substitutions of alternative phrases. PMID:23715801

  18. Results from CrIS/ATMS Obtained Using an "AIRS Version-6 Like" Retrieval Algorithm

    NASA Technical Reports Server (NTRS)

    Susskind, Joel; Kouvaris, Louis; Iredell, Lena; Blaisdell, John

    2015-01-01

    AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6.Monthly mean August 2014 Version-6.22 AIRS and CrIS products agree reasonably well with OMPS, CERES, and witheach other. JPL plans to process AIRS and CrIS for many months and compare interannual differences. Updates to thecalibration of both CrIS and ATMS are still being finalized. We are also working with JPL to develop a joint AIRS/CrISlevel-1 to level-3 processing system using a still to be finalized Version-7 retrieval algorithm. The NASA Goddard DISCwill eventually use this system to reprocess all AIRS and recalibrated CrIS/ATMS. .

  19. The conclusion of a comparative efficacy study of fluralaner and sarolaner against the tick Amblyomma americanum on dogs is based on results obtained at study times that are outside the fluralaner label recommendations.

    PubMed

    Armstrong, Rob

    2017-03-24

    The only fluralaner-related conclusion presented in a study comparing the efficacy of fluralaner and sarolaner for control of the tick Amblyomma americanum on dogs is based on study times that are outside the label administration recommendations. Label recommendations for fluralaner treatment of A. americanum on dogs in the USA require re-administration at 56 days. This 56 day re-administration was not conducted in the study; therefore, all assessed time points following 56 days post-treatment in the study present comparisons that are not consistent with fluralaner administration recommendations. The only comparative time point assessed prior to 56 days showing a difference between treatments was at 42 days post-administration, a time point when methodological problems were identified by the investigators. Therefore, the only comparative study conclusion that a difference was shown between fluralaner and sarolaner beyond 6 weeks (42 days) after treatment is not based on recommended product use. Furthermore, if the study does not show that there is a difference between the treatments at times when the products are used as recommended, then there also can be no comparative discussion of the risk of tick-borne pathogen transmission risk between treatments.

  20. Comparative Study Of Image Enhancement Algorithms For Digital And Film Mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delgado-Gonzalez, A.; Sanmiguel, R. E.

    2008-08-11

    Here we discuss the application of edge enhancement algorithms on images obtained with a Mammography System which has a Selenium Detector and on the other hand, on images obtained from digitized film mammography. Comparative analysis of such images includes the study of technical aspects of image acquisition, storage, compression and display. A protocol for a local database has been created as a result of this study.

  1. Reflectance confocal microscopy of tinea nigra: comparing images with dermoscopy and mycological examination results.

    PubMed

    Veasey, John Verrinder; Avila, Ricardo Bertozzi de; Ferreira, Marcus Antônio Maia de Olivas; Lazzarini, Rosana

    2017-01-01

    Tinea nigra is a superficial mycosis whose diagnosis is confirmed by isolating the infectious agent Hortae werneckii through mycological examinations. In vivo reflectance confocal microscopy, initially used in melanocytic dermatosis, has been used with skin infectious diseases to identify the parasite at the cellular level. We report, for the first time in the scientific literature, the use of reflectance confocal microscopy in a case of tinea nigra and compare its findings to dermoscopy and mycological examination results.

  2. Reflectance confocal microscopy of tinea nigra: comparing images with dermoscopy and mycological examination results*

    PubMed Central

    Veasey, John Verrinder; de Avila, Ricardo Bertozzi; Ferreira, Marcus Antônio Maia de Olivas; Lazzarini, Rosana

    2017-01-01

    Tinea nigra is a superficial mycosis whose diagnosis is confirmed by isolating the infectious agent Hortae werneckii through mycological examinations. In vivo reflectance confocal microscopy, initially used in melanocytic dermatosis, has been used with skin infectious diseases to identify the parasite at the cellular level. We report, for the first time in the scientific literature, the use of reflectance confocal microscopy in a case of tinea nigra and compare its findings to dermoscopy and mycological examination results. PMID:28954116

  3. NMR permeability estimators in 'chalk' carbonate rocks obtained under different relaxation times and MICP size scalings

    NASA Astrophysics Data System (ADS)

    Rios, Edmilson Helton; Figueiredo, Irineu; Moss, Adam Keith; Pritchard, Timothy Neil; Glassborow, Brent Anthony; Guedes Domingues, Ana Beatriz; Bagueira de Vasconcellos Azeredo, Rodrigo

    2016-07-01

    The effect of the selection of different nuclear magnetic resonance (NMR) relaxation times for permeability estimation is investigated for a set of fully brine-saturated rocks acquired from Cretaceous carbonate reservoirs in the North Sea and Middle East. Estimators that are obtained from the relaxation times based on the Pythagorean means are compared with estimators that are obtained from the relaxation times based on the concept of a cumulative saturation cut-off. Select portions of the longitudinal (T1) and transverse (T2) relaxation-time distributions are systematically evaluated by applying various cut-offs, analogous to the Winland-Pittman approach for mercury injection capillary pressure (MICP) curves. Finally, different approaches to matching the NMR and MICP distributions using different mean-based scaling factors are validated based on the performance of the related size-scaled estimators. The good results that were obtained demonstrate possible alternatives to the commonly adopted logarithmic mean estimator and reinforce the importance of NMR-MICP integration to improving carbonate permeability estimates.

  4. A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model.

    PubMed

    Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam

    2017-01-01

    The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t -test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis.

  5. Gonorrhoea and Syphilis Epidemiology in Flemish General Practice 2009–2013: Results from a Registry-based Retrospective Cohort Study Compared with Mandatory Notification

    PubMed Central

    Schweikardt, Christoph; Goderis, Geert; Elli, Steven; Coppieters, Yves

    2016-01-01

    Background The number of newly diagnosed gonorrhoea and syphilis cases has increased in Flanders in recent years. Our aim was to investigate, to which extent these diagnoses were registered by general practitioners (GPs), and to examine opportunities and limits of the Intego database in this regard. Methods Data from a retrospective cohort study based on the Flemish Intego general practice database was analyzed for the years 2009–2013. Case definitions were applied. Due to small case numbers obtained, cases were pooled and averaged over the observation period. Frequencies were compared with those calculated from figures of mandatory notification. Results A total of 91 gonorrhoea and 23 syphilis cases were registered. The average Intego annual frequency of gonorrhoea cases obtained was 11.9 (95% Poisson confidence interval (CI) 9.6; 14.7) per 100,000 population, and for syphilis 3.0 (CI 1.9; 4.5), respectively, while mandatory notification was calculated at 14.0 (CI: 13.6, 14.4) and 7.0 (CI: 6.7, 7.3), respectively. Conclusion In spite of limitations such as small numbers and different case definitions, comparison with mandatory notification suggests that the GP was involved in the large majority of gonorrhoea cases, while the majority of new syphilis cases did not come to the knowledge of the GP. PMID:29546196

  6. Drying effects on the antioxidant properties of polysaccharides obtained from Agaricus blazei Murrill.

    PubMed

    Wu, Songhai; Li, Feng; Jia, Shaoyi; Ren, Haitao; Gong, Guili; Wang, Yanyan; Lv, Zesheng; Liu, Yong

    2014-03-15

    Three polysaccharides (ABMP-F, ABMP-V, ABMP-A) were obtained from Agaricus blazei Murrill via methods such as freeze drying, vacuum drying and air drying, respectively. Their chemical compositions were examined, and antioxidant activities were investigated on the basis of assay for hydroxyl radical, DPPH radical, ABTS free radical scavenging ability and assay for Fe(2+)-chelating ability. Results showed that the three ABMPs have different physicochemical and antioxidant properties. Compared with air drying and vacuum drying methods, freeze drying method resulted to ABMP with higher neutral sugar, polysaccharide yield, uronic acid content, and stronger antioxidant abilities of hydroxyl radical, DPPH radical, ABTS radical scavenging and Fe(2+)-chelating. As a result, Agaricus blazei Murrill polysaccharides are natural antioxidant and freeze drying method serves as a good choice for the preparation of such polysaccharides and should be used to produce antioxidants for food industry. Copyright © 2014. Published by Elsevier Ltd.

  7. Thermal Effusivity of Vegetable Oils Obtained by a Photothermal Technique

    NASA Astrophysics Data System (ADS)

    Cervantes-Espinosa, L. M.; de L. Castillo-Alvarado, F.; Lara-Hernández, G.; Cruz-Orea, A.; Hernández-Aguilar, C.; Domínguez-Pacheco, A.

    2014-10-01

    Thermal properties of several vegetable oils such as soy, corn, and avocado commercial oils were obtained by using a photopyroelectric technique. The inverse photopyroelectric configuration was used in order to obtain the thermal effusivity of the oil samples. The theoretical equation for the photopyroelectric signal in this configuration, as a function of the incident light modulation frequency, was fitted to the experimental data in order to obtain the thermal effusivity of these samples. The obtained results are in good agreement with the thermal effusivity reported for other vegetable oils. All measurements were done at room temperature.

  8. Subordinate females in the cooperatively breeding Seychelles warbler obtain direct benefits by joining unrelated groups.

    PubMed

    Groenewoud, Frank; Kingma, Sjouke A; Hammers, Martijn; Dugdale, Hannah L; Burke, Terry; Richardson, David S; Komdeur, Jan

    2018-05-11

    -breeders, obtaining maternity in the new territory, and were likely to inherit the territory in the future, leading to higher lifetime reproductive success compared to females that floated. Males never reproduced as subordinates, which may be one explanation why subordinate between-group dispersal by males is rare. 6.Our results suggest that subordinate between-group dispersal is used by females to obtain reproductive benefits when options to disperse to an independent breeding position are limited. This provides important insight into the additional strategies that individuals can use to obtain reproductive benefits. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

    PubMed

    Ender, Andreas; Mehl, Albert

    2015-01-01

    To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.

  10. Comparative Flight Performance with an NACA Roots Supercharger and a Turbocentrifugal Supercharger

    NASA Technical Reports Server (NTRS)

    Schey, Oscar W; Young, Alfred W

    1931-01-01

    This report presents the comparative flight results of a roots supercharger and a turbocentrifugal supercharger. The tests were conducted using a modified DH-4M2 airplane. The rate of climb and the high speed in level flight of the airplane were obtained for each supercharger from sea level to the ceiling. The unsupercharged performance with each supercharger mounted in place was also determined. The results of these tests show that the ceiling and rate of climb obtained were nearly the same for each supercharger, but that the high speed obtained with the turbocentrifugal was better than that obtained with the roots. The high-speed performance at 21,000 feet was 122 and 142 miles per hour for the roots and turbocentrifugal, respectively.

  11. Non-invasive method to obtain DNA from freshwater mussels (Bivalvia: Unionidae)

    USGS Publications Warehouse

    Henley, W.F.; Grobler, P.J.; Neves, R.J.

    2006-01-01

    To determine whether DNA could be isolated from tissues obtained by brush-swabbing the mantle, viscera and foot, mantle-clips and swabbed cells were obtained from eight Quadrula pustulosa (Lea, 1831). DNA yields from clips and swabbings were 447.0 and 975.3 ??g/??L, respectively. Furthermore, comparisons of sequences from the ND-1 mitochondrial gene region showed a 100% sequence agreement of DNA from cells obtained by clips and swabs. To determine the number of swabs needed to obtain adequate yields of DNA for analyses, the visceras and feet of 5 Q. pustulosa each were successively swabbed 2, 4 and 6 times. DNA yields from the 2, 4 and 6 swabbed mussel groups were 399.4, 833.8 and 852.6 ng/??L, respectively. ND-1 sequences from the lowest yield still provided 846-901 bp for the ND-1 region. Nevertheless, to ensure adequate DNA yield from cell samples obtained by swabbing, we recommend that 4 swab-strokes of the viscera and foot be obtained. The use of integumental swabbing for collection of cells for determination of genetic relationships among freshwater mussels is noninvasive, when compared with tissue collection by mantle-clipping. Therefore, its use is recommended for freshwater mussels, especially state-protected or federally listed mussel species.

  12. Effect of diet on results obtained by use of two commercial test kits for detection of occult blood in feces of dogs.

    PubMed

    Cook, A K; Gilson, S D; Fischer, W D; Kass, P H

    1992-10-01

    To evaluate the effect of diet on results obtained by use of 2 commercial test kits for detection of occult blood in feces, 5 dogs were fed 7 diets in randomized sequence. Dry and canned diets with various principal ingredients were evaluated. Each diet was offered twice over a 24-hour period, followed by a 36-hour nonfeeding period. Fecal specimens were collected twice daily, and tests for occult blood were performed within 12 hours. The dietary origin of fecal specimens was confirmed by use of colored markers fed with each diet, and was correlated with estimates of gastrointestinal tract transit time. A modified guaiac paper test and an o-tolidine tablet test were performed on each specimen. Of 59 specimens, 4 were positive for occult blood, using the o-tolidine tablet test. Three positive results were associated with a mutton-based canned diet, and 1 positive result was associated with a canned beef-based diet. Of 59 specimens, 11 were positive for occult blood, using the modified guaiac paper test. Four positive results were associated with the mutton diet, and 3 positive results were associated with the beef diet. Of the remaining 5 diets, 4 caused 1 positive reaction. Results were inconsistent with the null hypothesis that the distribution of positive occult blood test results is not affected by diet (P < 0.025), and indicate that diet can affect the specificity of peroxidase-based tests for detection of occult blood in canine feces. Diet modification prior to testing is recommended.

  13. Comparing Medline citations using modified N-grams.

    PubMed

    Nawab, Rao Muhammad Adeel; Stevenson, Mark; Clough, Paul

    2014-01-01

    We aim to identify duplicate pairs of Medline citations, particularly when the documents are not identical but contain similar information. Duplicate pairs of citations are identified by comparing word n-grams in pairs of documents. N-grams are modified using two approaches which take account of the fact that the document may have been altered. These are: (1) deletion, an item in the n-gram is removed; and (2) substitution, an item in the n-gram is substituted with a similar term obtained from the Unified Medical Language System Metathesaurus. N-grams are also weighted using a score derived from a language model. Evaluation is carried out using a set of 520 Medline citation pairs, including a set of 260 manually verified duplicate pairs obtained from the Deja Vu database. The approach accurately detects duplicate Medline document pairs with an F1 measure score of 0.99. Allowing for word deletions and substitution improves performance. The best results are obtained by combining scores for n-grams of length 1-5 words. Results show that the detection of duplicate Medline citations can be improved by modifying n-grams and that high performance can also be obtained using only unigrams (F1=0.959), particularly when allowing for substitutions of alternative phrases.

  14. Comparison of Temperature Measurements in the Middle Atmosphere by Satellite with Profiles Obtained by Meteorological Rockets

    NASA Technical Reports Server (NTRS)

    Goldberg, Richard A.; Schmidlin, Francis J.; Feofilov, Artem; Bedrick, M.; Rose, R. Lynn

    2012-01-01

    Measurements using the inflatable falling sphere technique have occasionally been used to obtain temperature results from density data and thereby provide comparison with temperature profiles obtained by satellite sounders in the mesosphere and stratosphere. To insure density measurements within narrow time frames and close in space, the inflatable falling sphere is launched within seconds of the nearly overhead satellite pass. Sphere measurements can be used to validate remotely measured temperatures but also have the advantage of measuring small-scale atmospheric features. Even so, with the dearth of remaining falling spheres available (the manufacture of these systems has been discontinued), it may be time to consider whether the remote measurements are mature enough to stand alone. Three field studies are considered, one in 2003 from Northern Sweden, and two in 2010 from the vicinity of Kwajalein Atoll in the South Pacific and from Barking Sands, Hawaii. All three sites are used to compare temperature retrievals between satellite and in situ falling spheres. The major satellite instruments employed are SABER, MLS, and AIRS. The comparisons indicate that remotely measured temperatures mimic the sphere temperature measurements quite well. The data also confirm that satellite retrievals, while not always at the exact location required for detailed studies in space and time, compare sufficiently well to be highly useful. Although the falling sphere will provide a measurement at a specific location and time, satellites only pass a given location daily or less frequently. This report reveals that averaged satellite measurements can provide temperatures and densities comparable to those obtained from the falling sphere, thereby providing a reliable measure of global temperature

  15. Scintigraphic results in patients with lung transplants: a prospective comparative study.

    PubMed

    Humplik, B I; Sandrock, D; Aurisch, R; Richter, W-St; Ewert, R; Munz, D L

    2005-04-01

    We addressed the feasibility of scintigraphy in the postoperative monitoring of lung transplants. 37 patients (22 women, 15 men, 37 +/- 15 years) in good clinical condition were examined after lung transplantation. Scintigraphic procedures for assessing ventilation (133Xe), perfusion (99mTc microspheres) and aerosol-inhalation (99mTc aerosol) were performed for all patients. The findings were compared with those of established diagnostic modalities. All lung transplants showed homogeneous ventilation but with a non-physiologic difference of over 20% between both pulmonary lobes in one-third of the cases. There was a difference between the impairement of perfusion and ventilation in the presence of an impaired Euler-Liljestrand reflex in 14/37 (38%) patients. Furthermore, bronchoscopy and aerosol-inhalation scans often did not correlate, e. g. a bronchoscopically evident stenosis was not necessarily associated with an increased activity, and vice versa. Although peripheral mucociliary clearance was preserved after transplantation, stasis in central airways resulted in significantly impaired global clearance. Ventilation and perfusion scintigraphy reveal in a significant number of lung recipients pathologic findings and therefore can be recommended for postoperative monitoring. From a clinical point of view aerosol-inhalation scintigraphy (clearance) is not of any additional value.

  16. Remanence anisotropy effect on the palaeointensity results obtained from various archaeological materials, excluding pottery

    NASA Astrophysics Data System (ADS)

    Kovacheva, M.; Chauvin, A.; Jordanova, N.; Lanos, P.; Karloukovski, V.

    2009-06-01

    The effect of magnetic anisotropy on the palaeointensity results has been evaluated in different materials, including samples from archaeological structures of various ages, such as baked clay from prehistoric domestic ovens or pottery kilns, burnt soil from ancient fires, and bricks and bricks or tiles used in the kiln's construction. The remanence anisotropy was estimated by the thermoremanent (TRM) anisotropy tensor and isothermal remanence (IRM) tensor methods. The small anisotropy effect (less than 5%) observed in the palaeointensity results of baked clay from the relatively thin prehistoric oven's floors estimated previously through IRM anisotropy was confirmed by TRM anisotropy of this material. The new results demonstrate the possibility of using IRM anisotropy evaluation to correct baked clay palaeointensity data instead of the more difficult to determine TRM anisotropy ellipsoid. This is not always the case for the palaeointensity results from bricks and tiles. The anisotropy correction to palaeointensity results seems negligible for materials other than pottery. It would therefore appear that the palaeointensity determination is more sensitive to the degree of remanence anisotropy P and the angle between the natural remanent magnetization (NRM) vector and the laboratory field direction, than to the angle between the NRM and the maximum axis of the remanence anisotropy ellipsoid (Kmax).

  17. Comparison of ozone profiles obtained with NIES DIAL and SAGE II measurements

    NASA Technical Reports Server (NTRS)

    Nakane, Hideaki; Sasano, Yasuhiro; Hayashida-Amano, Sachiko; Sugimoto, Nobuo; Matsui, Ichiro; Minato, Atsushi; Mccormick, M. P.

    1993-01-01

    Ozone profiles obtained with the Differential Absorption Lidar (DIAL) system at the National Institute for Environmental Studies (NIES) (Tsukuba, Japan) were compared with data provided by the satellite sensor SAGE II. The SAGE II data were selected based on criteria of spatial and temporal differences between the DIAL and the SAGE II measurements: five degrees in latitude and 15 degrees in longitude, within a latitudinal band from 31 deg to 41 deg N, and within one, three and five days after or before the DIAL measurements. Results show very good agreement for the individual and the zonal-mean profiles. The average mean difference between the DIAL and the SAGE II measurements over the altitudes 15-50 km was about 10 percent.

  18. Jumbo forceps are superior to standard large-capacity forceps in obtaining diagnostically adequate inflammatory bowel disease surveillance biopsy specimens.

    PubMed

    Elmunzer, B Joseph; Higgins, Peter D R; Kwon, Yong M; Golembeski, Christopher; Greenson, Joel K; Korsnes, Sheryl J; Elta, Grace H

    2008-08-01

    In inflammatory bowel disease (IBD) surveillance colonoscopy, an increased number of biopsy specimens correlates with a higher dysplasia detection rate. Larger biopsy specimens may also increase the diagnostic yield. To compare a new jumbo forceps with a standard large-capacity forceps in obtaining diagnostically adequate IBD surveillance biopsy specimens. Prospective single-center study. Twenty-four patients who were undergoing an IBD surveillance colonoscopy were enrolled. As part of standard IBD surveillance, 8 paired biopsy specimens were obtained from the rectosigmoid by using the jumbo forceps and a standard large-capacity forceps. Biopsy specimens were deemed adequate if they met all 3 of the following criteria: (1) length > or =3 mm, (2) penetration into the muscularis mucosa, and (3) < 20% crush artifact. The proportion of adequate biopsy specimens obtained with the jumbo forceps was significantly higher than that obtained with the large-capacity control forceps (67% vs 48%, P < .0001). The average length of the biopsy specimen obtained with the jumbo forceps was 4.00 mm (95% CI, 3.81-4.20 mm) compared with 3.19 mm (95% CI, 2.99-3.38 mm) with the large-capacity (control) forceps. (1) No validated outcome measurement for the quality of GI biopsy specimens exists and (2) in this study, interobserver variability between pathologists was high. The jumbo forceps was superior to a standard large-capacity forceps in obtaining diagnostically adequate IBD surveillance biopsy specimens. Because biopsy specimens obtained with the jumbo forceps were larger, the use of this forceps for IBD surveillance will allow the endoscopist to sample a larger colonic mucosal surface area, potentially resulting in an increased dysplasia detection rate.

  19. Packaging and labeling of pharmaceutical products obtained from the internet.

    PubMed

    Veronin, Michael

    2011-02-15

    For patients, the prescription container label may be the only source of instructions on how to take their medicines. In the United States, the legal requirements for a prescription label are set by federal law and state statutes. The container should be comparable to that which manufacturers use to package drug products and should preserve a product's identity, strength, quality, and purity and prevent contamination. Safety features such as a child-resistant closure should be provided. Pharmaceutical products purchased from international online pharmacies are not approved by the Food and Drug Administration (FDA) and may not meet US guidelines for labeling and packaging. The study objective was to determine whether commonly purchased pharmaceutical products obtained from international online pharmacies are comparable to products dispensed in the United States with regard to labeling and packaging. During March 2006 through January 2007, 41 pharmaceutical oral dosage form samples were obtained from international Internet pharmacy websites for evaluation: 18 generic simvastatin samples, 18 generic amlodipine samples, and 5 generic sildenafil samples. Contents for each package were observed and recorded and comparison of the prescription labeling and packaging of these products was made with prescription labeling and packaging requirements in the United States. Of the 41 drug products obtained from online pharmacies from 12 different countries, only 1 product (from Canada) would meet both labeling and packaging guidelines for products dispensed in the United States. Of those not meeting the requirements, 7 were dispensed in paper envelopes with label affixed that was either handwritten or typed and contained missing information such as name and address of dispenser, name of prescriber, name of patient, and directions for use. Another 3 products did not have a label affixed to the drug product, but information was printed on a paper document enclosed in the shipping

  20. Butter increased total and LDL cholesterol compared with olive oil but resulted in higher HDL cholesterol compared with a habitual diet.

    PubMed

    Engel, Sara; Tholstrup, Tine

    2015-08-01

    Butter is known to have a cholesterol-raising effect and, therefore, has often been included as a negative control in dietary studies, whereas the effect of moderate butter intake has not been elucidated to our knowledge. We compared the effects of moderate butter intake, moderate olive oil intake, and a habitual diet on blood lipids, high-sensitivity C-reactive protein (hsCRP), glucose, and insulin. The study was a controlled, double-blinded, randomized 2 × 5-wk crossover dietary intervention study with a 14-d run-in period during which subjects consumed their habitual diets. The study included 47 healthy men and women (mean ± SD total cholesterol: 5.22 ± 0.90 mmol/L) who substituted a part of their habitual diets with 4.5% of energy from butter or refined olive oil. Study subjects were 70% women with a mean age and body mass index (in kg/m²) of 40.4 y and 23.5, respectively. Butter intake increased total cholesterol and LDL cholesterol more than did olive oil intake (P < 0.05) and the run-in period (P < 0.005 and P < 0.05, respectively) and increased HDL cholesterol compared with the run-in period (P < 0.05). No difference in effects was observed for triacylglycerol, hsCRP, insulin, and glucose concentrations. The intake of saturated fatty acids was significantly higher in the butter period than in the olive oil and run-in periods (P < 0.0001). Moderate intake of butter resulted in increases in total cholesterol and LDL cholesterol compared with the effects of olive oil intake and a habitual diet (run-in period). Furthermore, moderate butter intake was also followed by an increase in HDL cholesterol compared with the habitual diet. We conclude that hypercholesterolemic people should keep their consumption of butter to a minimum, whereas moderate butter intake may be considered part of the diet in the normocholesterolemic population. © 2015 American Society for Nutrition.

  1. Obtaining an equivalent beam

    NASA Technical Reports Server (NTRS)

    Butler, Thomas G.

    1990-01-01

    In modeling a complex structure the researcher was faced with a component that would have logical appeal if it were modeled as a beam. The structure was a mast of a robot controlled gantry crane. The structure up to this point already had a large number of degrees of freedom, so the idea of conserving grid points by modeling the mast as a beam was attractive. The researcher decided to make a separate problem of of the mast and model it in three dimensions with plates, then extract the equivalent beam properties by setting up the loading to simulate beam-like deformation and constraints. The results could then be used to represent the mast as a beam in the full model. A comparison was made of properties derived from models of different constraints versus manual calculations. The researcher shows that the three-dimensional model is ineffective in trying to conform to the requirements of an equivalent beam representation. If a full 3-D plate model were used in the complete representation of the crane structure, good results would be obtained. Since the attempt is to economize on the size of the model, a better way to achieve the same results is to use substructuring and condense the mast to equivalent end boundary and intermediate mass points.

  2. Obstetrician–Gynecologists’ Objections to and Willingness to Help Patients Obtain an Abortion

    PubMed Central

    Harris, Lisa H; Cooper, Alexandra; Rasinski, Kenneth A; Curlin, Farr A; Lyerly, Anne Drapkin

    2014-01-01

    Objective To describe obstetrician–gynecologists’ (ob-gyns) views and willingness to help women seeking abortion in a variety of clinical scenarios. Methods We conducted a mailed survey of 1,800 U.S. ob-gyns. We presented seven scenarios in which patients sought abortion. For each, respondents indicated if they morally objected to abortion and if they would help patients obtain an abortion. We analyzed predictors of objection and assistance. Results The response rate was 66%. Objection to abortion ranged from 16% (cardiopulmonary disease) to 82% (sex selection); willingness to assist ranged from 64% (sex selection) to 93% (cardiopulmonary disease). Excluding sex selection, objection was less likely among ob-gyns who were female (odds ratio [OR] 0.5, 95% confidence interval [CI] 0.4–0.8), urban (OR 0.3, CI 0.1–0.7), or Jewish (OR 0.3, CI 0.1–0.7) compared to male, rural, or unaffiliated ob-gyns. Objection was more likely among ob-gyns from the South (OR 1.9, CI 1.2–3.0) or Midwest (OR 1.9, CI 1.2–3.1), and among Catholic, evangelical Protestant, or Muslim ob-gyns, or those for whom religion was most important, compared to reference. Among ob-gyns who objected to abortion in a given case, approximately two-thirds nevertheless help patients obtain an abortion. Excluding sex selection, assistance despite objection was more likely among female (OR 1.8, CI 1.1–2.9) and US-born ob-gyns (OR 2.2, CI 1.1–4.7), and less likely among Southern ob-gyns (OR 0.3, CI 0.2–0.6), or those for whom religion was most important (OR 0.3, CI 0.1–0.7). Conclusions Most ob-gyns help patients obtain an abortion even when they morally object to abortion in that case. Willingness to assist varies by clinical context and physician characteristics. PMID:21934455

  3. Results of multiple drilling compared with those of conventional methods of core decompression.

    PubMed

    Song, Won Seok; Yoo, Jeong Joon; Kim, Young-Min; Kim, Hee Joong

    2007-01-01

    We performed multiple drilling as a femoral head-preserving procedure for osteonecrosis of the femoral head thinking the therapeutic effects of core decompression could be achieved by this simpler procedure than core decompression. We retrospectively reviewed 136 patients (163 hips) who had multiple drilling using 9/64-inch Steinmann pins for treatment of nontraumatic osteonecrosis of the femoral head. The mean followup for patients who did not require additional surgery (113 hips) was 87 months (range, 60-134 months). We defined failure as the need for additional surgery or a Harris hip score less than 75. After a minimum 5-year followup, 79% (31/39) of patients with Stage I disease and 77% (62/81) of patients with Stage II disease had no additional surgery. All (15/15) small lesions (<25% involvement) and 84% (37/44) of medium-sized lesions (25-50% involvement) were considered successful. Survival rates of patients with Ficat Stages I or II lesions were greater than survival rates for patients with Stage III lesions. Hips with a large necrotic area had poor results. We had one instance of subtrochanteric fracture through drill entry holes. Multiple drilling is straightforward with few complications and produces results comparable to results of other core decompression techniques.

  4. Obtaining Reimbursement in France and Italy for New Diabetes Products

    PubMed Central

    Schaefer, Elmar; Sonsalla, Jessica

    2015-01-01

    Manufacturers launching next-generation or innovative medical devices in Europe face a very heterogeneous reimbursement landscape, with each country having its own pathways, timing, requirements and success factors. We selected 2 markets for a deeper look into the reimbursement landscape: France, representing a country with central decision making with defined processes, and Italy, which delegates reimbursement decisions to the regional level, resulting in a less transparent approach to reimbursement. Based on our experience in working on various new product launches and analyzing recent reimbursement decisions, we found that payers in both countries do not reward improved next-generation products with incremental reimbursement. Looking at innovations, we observe that manufacturers face a challenging and lengthy process to obtain reimbursement. In addition, requirements and key success factors differ by country: In France, comparative clinical evidence and budget impact very much drive reimbursement decisions in terms of pricing and restrictions, whereas in Italy, regional key opinion leader (KOL) support and additional local observational data are key. PMID:25550411

  5. Investigation of the Maximum Spin-Up Coefficients of Friction Obtained During Tests of a Landing Gear Having a Static-Load Rating of 20,000 Pounds

    NASA Technical Reports Server (NTRS)

    Batterson, Sidney A.

    1959-01-01

    An experimental investigation was made at the Langley landing loads track to obtain data on the maximum spin-up coefficients of friction developed by a landing gear having a static-load rating of 20,000 pounds. The forward speeds ranged from 0 to approximately 180 feet per second and the sinking speeds, from 2.7 feet per second to 9.4 feet per second. The results indicated the variation of the maximum spin-up coefficient of friction with forward speed and vertical load. Data obtained during this investigation are also compared with some results previously obtained for nonrolling tires to show the effect of forward speed.

  6. Supercritical CO2/Co-solvents Extraction of Porogen and Surfactant to Obtain

    NASA Astrophysics Data System (ADS)

    Lubguban, Jorge

    2005-03-01

    A method of pore generation by supercritical CO2 (SCCO2)/co-solvents extraction for the preparation of nanoporous organosilicate thin films for ultralow dielectric constant materials is investigated. A nanohybrid film was prepared from poly (propylene glycol) (PPG) and poly(methylsilsesquioxane) (PMSSQ) whereby the PPG porogen are entrapped within the crosslinked PMSSQ matrix. Another set of thin films was produced by liquid crystal templating whereby non-ionic (polyoxyethylene 10 stearyl ether) (Brij76) and ionic (cetyltrimethylammonium bromide) (CTAB) surfactant were used as sacrificial templates in a tetraethoxy silane (TEOS) and methyltrimethoxy silane (MTMS) based matrix. These two types of films were treated with SCCO2/co-solvents to remove porogen and surfactant templates. As a comparison, porous structures generated by thermal decomposition were also evaluated. It is found that SCCO2/co-solvents treatment produced closely comparable results with thermal decomposition. The results were evident from Fourier Transform Infrared (FT- IR) spectroscopy and optical constants data obtained from variable angle spectroscopic ellipsometry (VASE).

  7. Commercial programs' online weight loss claims as compared to results from randomized controlled trials

    PubMed Central

    Vakil, Rachit M.; Chaudhry, Zoobia W.; Doshi, Ruchi S.; Clark, Jeanne M.; Gudzune, Kimberly A.

    2017-01-01

    Objective To characterize weight-loss claims and disclaimers present on websites for commercial weight-loss programs and compare them to results from published randomized controlled trials (RCT). Methods We performed a content analysis of all homepages and testimonials available on the websites of 24 randomly selected programs. Two team members independently reviewed each page and abstracted information from text and images to capture relevant content including demographics, weight loss, and disclaimers. We performed a systematic review to evaluate the efficacy of these programs by searching MEDLINE and Cochrane Database of Systematic Reviews, and abstracted mean weight change from each included RCT. Results Overall, the amount of weight loss portrayed in the testimonials was extreme across all programs examined (range median weight loss 10.7 to 49.5 kg). Only 10 out of the 24 programs had eligible RCTs. Median weight losses reported in testimonials exceeded that achieved by trial participants. Most programs with RCTs (78%) provided disclaimers stating that the testimonial's results were non-typical and/or giving a range of typical weight loss. Conclusion Weight loss claims within testimonials were higher than results from RCTs. Future studies should examine whether commercial programs' advertising practices influence patients' expectations or satisfaction with modest weight loss results. PMID:28865085

  8. In vitro and in vivo tissue harmonic images obtained with parallel transmit beamforming by means of orthogonal frequency division multiplexing.

    PubMed

    Demi, Libertario; Ramalli, Alessandro; Giannini, Gabriele; Mischi, Massimo

    2015-01-01

    In classic pulse-echo ultrasound imaging, the data acquisition rate is limited by the speed of sound. To overcome this, parallel beamforming techniques in transmit (PBT) and in receive (PBR) mode have been proposed. In particular, PBT techniques, based on the transmission of focused beams, are more suitable for harmonic imaging because they are capable of generating stronger harmonics. Recently, orthogonal frequency division multiplexing (OFDM) has been investigated as a means to obtain parallel beamformed tissue harmonic images. To date, only numerical studies and experiments in water have been performed, hence neglecting the effect of frequencydependent absorption. Here we present the first in vitro and in vivo tissue harmonic images obtained with PBT by means of OFDM, and we compare the results with classic B-mode tissue harmonic imaging. The resulting contrast-to-noise ratio, here used as a performance metric, is comparable. A reduction by 2 dB is observed for the case in which three parallel lines are reconstructed. In conclusion, the applicability of this technique to ultrasonography as a means to improve the data acquisition rate is confirmed.

  9. Obtaining land cover changes information from multitemporal analysis of Landsat-TM images: results from a case study in West African dryland

    NASA Astrophysics Data System (ADS)

    Nutini, F.; Boschetti, M.; Brivio, P. A.; Antoninetti, M.

    2012-04-01

    The Sahelian belt of West Africa is a semiarid region characterized by wide climate variations, which can in turn affect the livelihood of local populations particularly in rangeland areas, as happens during the dramatic food crisis in the 70-80s caused by rainfall scarcity. The monitoring of natural resources and rainfed agricultural activities, with the aim to provide information to support Sahelian food security action, needs the production of detailed thematic maps as emphasized by several scientific papers. In this framework, a study was conducted to develop a method to exploit time series of remote sensed satellite data to 1) provide reliable land cover (LC) map at local scale in a dry region and 2) obtain a LC change (LCC) map that contribute to identify the plausible causes of local environmental instability. Satellite images used for this work consist in a time series of Landsat Thematic Mapper (TM) (path row 195-50) acquired in the 2000 (6 scenes) and 2007 (9 scenes) from February (Dry season) to September (end of wet season). The study investigates the different contribution provided by spectra information of a single Landsat TM image and by time series of derived NDVI. Different tests have been conducted with different combination of data set (spectral and temporal)in order to identify the best approach to obtain a LC map in five classes of interest: Shrubland, Cultivated Land, Water body, Herbaceous vegetation and Bare soil. The best classification approach is exposed and applied on two years in the last decade. The comparison between this two LC results in land cover change map, that displays the changes of vegetation patterns that have been characterized the area. The discussed results show a largely stable dryland region, but locally characterized by hot-spot of decreasing in natural vegetation inside the rangelands and an increasing of cultivations along fossil valleys where human activities are slightly intense. The discussion shows that this hot

  10. A comparative study between shielded and open coplanar waveguide discontinuities

    NASA Technical Reports Server (NTRS)

    Dib, Nihad I.; Harokopus, W. P., Jr.; Ponchak, G. E.; Katehi, L. P. B.

    1993-01-01

    A comparative study between open and shielded coplanar waveguide (CPW) discontinuities is presented. The space domain integral equation method is used to characterize several discontinuities such as the open-end CPW and CPW series stubs. Two different geometries of CPW series stubs (straight and bent stubs) are compared with respect to resonant frequency and radiation loss. In addition, the encountered radiation loss due to different CPW shunt stubs is evaluated experimentally. The notion of forced radiation simulation is presented, and the results of such a simulation are compared to the actual radiation loss obtained rigorously. It is shown that such a simulation cannot give reliable results concerning radiation loss from printed circuits.

  11. Gestational Weight Gain: Results from the Delta Healthy Sprouts Comparative Impact Trial.

    PubMed

    Thomson, Jessica L; Tussing-Humphreys, Lisa M; Goodman, Melissa H; Olender, Sarah E

    2016-01-01

    Introduction. Delta Healthy Sprouts trial was designed to test the comparative impact of two home visiting programs on weight status, dietary intake, and health behaviors of Southern African American women and their infants. Results pertaining to the primary outcome, gestational weight gain, are reported. Methods. Participants (n = 82), enrolled early in their second trimester of pregnancy, were randomly assigned to one of two treatment arms. Gestational weight gain, measured at six monthly home visits, was calculated by subtracting measured weight at each visit from self-reported prepregnancy weight. Weight gain was classified as under, within, or exceeding the Institute of Medicine recommendations based on prepregnancy body mass index. Chi-square tests and generalized linear mixed models were used to test for significant differences in percentages of participants within recommended weight gain ranges. Results. Differences in percentages of participants within the gestational weight gain guidelines were not significant between treatment arms across all visits. Conclusions. Enhancing the gestational nutrition and physical activity components of an existing home visiting program is feasible in a high risk population of primarily low income African American women. The impact of these enhancements on appropriate gestational weight gain is questionable given the more basic living needs of such women. This trial is registered with ClinicalTrials.gov NCT01746394, registered 4 December 2012.

  12. Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Saima, E-mail: saima.ali@aalto.fi; Hannula, Simo-Pekka

    Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO{sub 4}) solution (Process 1), and ethylene glycol (EG) mixture with HClO{sub 4} and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted tomore » nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25–600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m{sup 2} g{sup −1} is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes. - Graphical

  13. Recent Advances in Solid Catalysts Obtained by Metalloporphyrins Immobilization on Layered Anionic Exchangers: A Short Review and Some New Catalytic Results.

    PubMed

    Nakagaki, Shirley; Mantovani, Karen Mary; Machado, Guilherme Sippel; Castro, Kelly Aparecida Dias de Freitas; Wypych, Fernando

    2016-02-29

    Layered materials are a very interesting class of compounds obtained by stacking of two-dimensional layers along the basal axis. A remarkable property of these materials is their capacity to interact with a variety of chemical species, irrespective of their charge (neutral, cationic or anionic). These species can be grafted onto the surface of the layered materials or intercalated between the layers, to expand or contract the interlayer distance. Metalloporphyrins, which are typically soluble oxidation catalysts, are examples of molecules that can interact with layered materials. This work presents a short review of the studies involving metalloporphyrin immobilization on two different anionic exchangers, Layered Double Hydroxides (LDHs) and Layered Hydroxide Salts (LHSs), published over the past year. After immobilization of anionic porphyrins, the resulting solids behave as reusable catalysts for heterogeneous oxidation processes. Although a large number of publications involving metalloporphyrin immobilization on LDHs exist, only a few papers have dealt with LHSs as supports, so metalloporphyrins immobilized on LHSs represent a new and promising research field. This work also describes new results on an anionic manganese porphyrin (MnP) immobilized on Mg/Al-LDH solids with different nominal Mg/Al molar ratios (2:1, 3:1 and 4:1) and intercalated with different anions (CO₃(2-) or NO₃(-)). The influence of the support composition on the MnP immobilization rates and the catalytic performance of the resulting solid in cyclooctene oxidation reactions will be reported.

  14. Whole-comparative genomic hybridization in domestic sheep (Ovis aries) breeds.

    PubMed

    Dávila-Rodríguez, M I; Cortés-Gutiérrez, E I; López-Fernández, C; Pita, M; Mezzanotte, R; Gosálvez, J

    2009-01-01

    Whole-comparative genomic hybridization (W-CGH) allows identification of chromosomal polymorphisms related to highly repetitive DNA sequences localized in constitutive heterochromatin. Such polymorphisms are detected establishing competition between genomic DNAs in an in situ hybridization environment without subtraction of highly repetitive DNA sequences, when comparing two species from closely related taxa (same species, sub-species, or breeds) or somewhat related taxa. This experimental approach was applied to investigating differences in highly repetitive sequences of three sheep breeds (Castellana, Ojalada, and Assaf). To this end, W-CGH was carried out using mouflon (sheep ancestor) chromosomes as a common target to co-hybridize equimolar quantities of two genomic DNAs obtained from either Castellana, Ojalada or Assaf sheep breeds. The results showed that the amount of constitutive heterochromatin is greater in all pericentromeric heterochromatin regions of acrocentric chromosomes than in metacentric or sex chromosomes. Additionally, when W-CGH was performed using DNAs from the Iberian breeds Castellana and Ojalada, chromosomal pericentromeric regions revealed quantitatively and qualitatively a presence of DNA families similar to that obtained from any of the above-cited breeds. On the contrary, when the DNA used in W-CGH experiments was obtained from Assaf, as compared to either Castellana or Ojalada, two different pericentromeric DNA families of highly repetitive sequences could be detected. Lastly, sex chromosomes were shown to be homogeneous among all breeds and thus revealed no detectable constitutive heterochromatin. W-CGH results were confirmed using DNA breakage detection-FISH experiments (DBD-FISH) carried out on lymphocytes. As a whole, the results showed that two different repetitive DNA families are present in the pericentromeric heterochromatin of the sheep breeds studied here. Additionally, they suggest a differential presence of these distinct

  15. Results of community deliberation about social impacts of ecological restoration: comparing public input of self-selected versus actively engaged community members.

    PubMed

    Harris, Charles C; Nielsen, Erik A; Becker, Dennis R; Blahna, Dale J; McLaughlin, William J

    2012-08-01

    Participatory processes for obtaining residents' input about community impacts of proposed environmental management actions have long raised concerns about who participates in public involvement efforts and whose interests they represent. This study explored methods of broad-based involvement and the role of deliberation in social impact assessment. Interactive community forums were conducted in 27 communities to solicit public input on proposed alternatives for recovering wild salmon in the Pacific Northwest US. Individuals identified by fellow residents as most active and involved in community affairs ("AE residents") were invited to participate in deliberations about likely social impacts of proposed engineering and ecological actions such as dam removal. Judgments of these AE participants about community impacts were compared with the judgments of residents motivated to attend a forum out of personal interest, who were designated as self-selected ("SS") participants. While the magnitude of impacts rated by SS participants across all communities differed significantly from AE participants' ratings, in-depth analysis of results from two community case studies found that both AE and SS participants identified a large and diverse set of unique impacts, as well as many of the same kinds of impacts. Thus, inclusion of both kinds of residents resulted in a greater range of impacts for consideration in the environmental impact study. The case study results also found that the extent to which similar kinds of impacts are specified by AE and SS group members can differ by type of community. Study results caution against simplistic conclusions drawn from this approach to community-wide public participation. Nonetheless, the results affirm that deliberative methods for community-based impact assessment involving both AE and SS residents can provide a more complete picture of perceived impacts of proposed restoration activities.

  16. Results of Community Deliberation About Social Impacts of Ecological Restoration: Comparing Public Input of Self-Selected Versus Actively Engaged Community Members

    NASA Astrophysics Data System (ADS)

    Harris, Charles C.; Nielsen, Erik A.; Becker, Dennis R.; Blahna, Dale J.; McLaughlin, William J.

    2012-08-01

    Participatory processes for obtaining residents' input about community impacts of proposed environmental management actions have long raised concerns about who participates in public involvement efforts and whose interests they represent. This study explored methods of broad-based involvement and the role of deliberation in social impact assessment. Interactive community forums were conducted in 27 communities to solicit public input on proposed alternatives for recovering wild salmon in the Pacific Northwest US. Individuals identified by fellow residents as most active and involved in community affairs ("AE residents") were invited to participate in deliberations about likely social impacts of proposed engineering and ecological actions such as dam removal. Judgments of these AE participants about community impacts were compared with the judgments of residents motivated to attend a forum out of personal interest, who were designated as self-selected ("SS") participants. While the magnitude of impacts rated by SS participants across all communities differed significantly from AE participants' ratings, in-depth analysis of results from two community case studies found that both AE and SS participants identified a large and diverse set of unique impacts, as well as many of the same kinds of impacts. Thus, inclusion of both kinds of residents resulted in a greater range of impacts for consideration in the environmental impact study. The case study results also found that the extent to which similar kinds of impacts are specified by AE and SS group members can differ by type of community. Study results caution against simplistic conclusions drawn from this approach to community-wide public participation. Nonetheless, the results affirm that deliberative methods for community-based impact assessment involving both AE and SS residents can provide a more complete picture of perceived impacts of proposed restoration activities.

  17. Obtaining identical results with double precision global accuracy on different numbers of processors in parallel particle Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleveland, Mathew A., E-mail: cleveland7@llnl.gov; Brunner, Thomas A.; Gentile, Nicholas A.

    2013-10-15

    We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositionsmore » will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.« less

  18. Comparative optical analysis of cylindrical solar concentrators.

    PubMed

    Durán, J C; Nicolás, R O

    1987-02-01

    A comparison of the intensity distribution in the receiver plane for five different types of cylindrical concentrators is made. To this end, our previous 2-D optical analysis for nonperfect concentrators with plane receivers is used. Values of the local and mean concentration factors for a characteristic set of parameters of each concentrator are obtained and compared. The results show that the cylindrical-parabolic concentrator attains the highest concentration factors among the concentrators considered.

  19. Micrometric precision of prosthetic dental crowns obtained by optical scanning and computer-aided designing/computer-aided manufacturing system

    NASA Astrophysics Data System (ADS)

    das Neves, Flávio Domingues; de Almeida Prado Naves Carneiro, Thiago; do Prado, Célio Jesus; Prudente, Marcel Santana; Zancopé, Karla; Davi, Letícia Resende; Mendonça, Gustavo; Soares, Carlos José

    2014-08-01

    The current study evaluated prosthetic dental crowns obtained by optical scanning and a computer-aided designing/computer-aided manufacturing system using micro-computed tomography to compare the marginal fit. The virtual models were obtained with four different scanning surfaces: typodont (T), regular impressions (RI), master casts (MC), and powdered master casts (PMC). Five virtual models were obtained for each group. For each model, a crown was designed on the software and milled from feldspathic ceramic blocks. Micro-CT images were obtained for marginal gap measurements and the data were statistically analyzed by one-way analysis of variance followed by Tukey's test. The mean vertical misfit was T=62.6±65.2 μm; MC=60.4±38.4 μm; PMC=58.1±38.0 μm, and RI=89.8±62.8 μm. Considering a percentage of vertical marginal gap of up to 75 μm, the results were T=71.5%, RI=49.2%, MC=69.6%, and PMC=71.2%. The percentages of horizontal overextension were T=8.5%, RI=0%, MC=0.8%, and PMC=3.8%. Based on the results, virtual model acquisition by scanning the typodont (simulated mouth) or MC, with or without powder, showed acceptable values for the marginal gap. The higher result of marginal gap of the RI group suggests that it is preferable to scan this directly from the mouth or from MC.

  20. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    PubMed

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (<50 or ≥60 years) and BP (<140/90 mm Hg or ≥140/90 mm Hg). Three simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (P<.01). However, the first sequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, P<.01 for both). Within-visit reproducibility was identical (both r=0.60). Simultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  1. Life test results for the advanced very high resolution radiometer scanner

    NASA Technical Reports Server (NTRS)

    Lenz, James

    1996-01-01

    The following paper reports the results obtained during a 3.33-year life test on the TIROS Advanced Very High Resolution Radiometer/3 (AVHRR/3) Scanner. The bearing drag torque and lubricant loss over life will be compared to predicted values developed through modeling. The condition of the lubricant at the end of the test will be described and a theory presented to explain the results obtained. The differences (if any) in the predicted and measured values of drag torque and lubricant loss will be discussed and possible reasons for these examined.

  2. Uncertainties in obtaining high reliability from stress-strength models

    NASA Technical Reports Server (NTRS)

    Neal, Donald M.; Matthews, William T.; Vangel, Mark G.

    1992-01-01

    There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.

  3. SU-E-T-212: Comparison of TG-43 Dosimetric Parameters of Low and High Energy Brachytherapy Sources Obtained by MCNP Code Versions of 4C, X and 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zehtabian, M; Zaker, N; Sina, S

    2015-06-15

    Purpose: Different versions of MCNP code are widely used for dosimetry purposes. The purpose of this study is to compare different versions of the MCNP codes in dosimetric evaluation of different brachytherapy sources. Methods: The TG-43 parameters such as dose rate constant, radial dose function, and anisotropy function of different brachytherapy sources, i.e. Pd-103, I-125, Ir-192, and Cs-137 were calculated in water phantom. The results obtained by three versions of Monte Carlo codes (MCNP4C, MCNPX, MCNP5) were compared for low and high energy brachytherapy sources. Then the cross section library of MCNP4C code was changed to ENDF/B-VI release 8 whichmore » is used in MCNP5 and MCNPX codes. Finally, the TG-43 parameters obtained using the MCNP4C-revised code, were compared with other codes. Results: The results of these investigations indicate that for high energy sources, the differences in TG-43 parameters between the codes are less than 1% for Ir-192 and less than 0.5% for Cs-137. However for low energy sources like I-125 and Pd-103, large discrepancies are observed in the g(r) values obtained by MCNP4C and the two other codes. The differences between g(r) values calculated using MCNP4C and MCNP5 at the distance of 6cm were found to be about 17% and 28% for I-125 and Pd-103 respectively. The results obtained with MCNP4C-revised and MCNPX were similar. However, the maximum difference between the results obtained with the MCNP5 and MCNP4C-revised codes was 2% at 6cm. Conclusion: The results indicate that using MCNP4C code for dosimetry of low energy brachytherapy sources can cause large errors in the results. Therefore it is recommended not to use this code for low energy sources, unless its cross section library is changed. Since the results obtained with MCNP4C-revised and MCNPX were similar, it is concluded that the difference between MCNP4C and MCNPX is their cross section libraries.« less

  4. Kinetic study of Candida antarctica lipase B immobilization using poly(methyl methacrylate) nanoparticles obtained by miniemulsion polymerization as support.

    PubMed

    Valério, Alexsandra; Nicoletti, Gabrieli; Cipolatti, Eliane P; Ninow, Jorge L; Araújo, Pedro H H; Sayer, Cláudia; de Oliveira, Débora

    2015-03-01

    With the objective to obtain immobilized Candida antarctica lipase B (CalB) with good activity and improved utilization rate, this study evaluated the influence of enzyme and crodamol concentrations and initiator type on the CalB enzyme immobilization in nanoparticles consisting of poly(methyl methacrylate) (PMMA) obtained by miniemulsion polymerization. The kinetic study of immobilized CalB enzyme in PMMA nanoparticles was evaluated in terms of monomer conversion, particle size, zeta potential, and relative activity. The optimum immobilization condition for CalB was compared with free enzyme in the p-NPL hydrolysis activity measurement. Results showed a higher CalB enzyme stability after 20 hydrolysis cycles compared with free CalB enzyme; in particular, the relative immobilized enzyme activity was maintained up to 40%. In conclusion, PMMA nanoparticles proved to be a good support for the CalB enzyme immobilization and may be used as a feasible alternative catalyst in industrial processes.

  5. Serial isoelectric focusing as an effective and economic way to obtain maximal resolution and high-throughput in 2D-based comparative proteomics of scarce samples: proof-of-principle.

    PubMed

    Farhoud, Murtada H; Wessels, Hans J C T; Wevers, Ron A; van Engelen, Baziel G; van den Heuvel, Lambert P; Smeitink, Jan A

    2005-01-01

    In 2D-based comparative proteomics of scarce samples, such as limited patient material, established methods for prefractionation and subsequent use of different narrow range IPG strips to increase overall resolution are difficult to apply. Also, a high number of samples, a prerequisite for drawing meaningful conclusions when pathological and control samples are considered, will increase the associated amount of work almost exponentially. Here, we introduce a novel, effective, and economic method designed to obtain maximum 2D resolution while maintaining the high throughput necessary to perform large-scale comparative proteomics studies. The method is based on connecting different IPG strips serially head-to-tail so that a complete line of different IPG strips with sequential pH regions can be focused in the same experiment. We show that when 3 IPG strips (covering together the pH range of 3-11) are connected head-to-tail an optimal resolution is achieved along the whole pH range. Sample consumption, time required, and associated costs are reduced by almost 70%, and the workload is reduced significantly.

  6. High viscosity environments: an unexpected route to obtain true atomic resolution with atomic force microscopy.

    PubMed

    Weber, Stefan A L; Kilpatrick, Jason I; Brosnan, Timothy M; Jarvis, Suzanne P; Rodriguez, Brian J

    2014-05-02

    Atomic force microscopy (AFM) is widely used in liquid environments, where true atomic resolution at the solid-liquid interface can now be routinely achieved. It is generally expected that AFM operation in more viscous environments results in an increased noise contribution from the thermal motion of the cantilever, thereby reducing the signal-to-noise ratio (SNR). Thus, viscous fluids such as ionic and organic liquids have been generally avoided for high-resolution AFM studies despite their relevance to, e.g. energy applications. Here, we investigate the thermal noise limitations of dynamic AFM operation in both low and high viscosity environments theoretically, deriving expressions for the amplitude, phase and frequency noise resulting from the thermal motion of the cantilever, thereby defining the performance limits of amplitude modulation, phase modulation and frequency modulation AFM. We show that the assumption of a reduced SNR in viscous environments is not inherent to the technique and demonstrate that SNR values comparable to ultra-high vacuum systems can be obtained in high viscosity environments under certain conditions. Finally, we have obtained true atomic resolution images of highly ordered pyrolytic graphite and mica surfaces, thus revealing the potential of high-resolution imaging in high viscosity environments.

  7. High viscosity environments: an unexpected route to obtain true atomic resolution with atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Weber, Stefan A. L.; Kilpatrick, Jason I.; Brosnan, Timothy M.; Jarvis, Suzanne P.; Rodriguez, Brian J.

    2014-05-01

    Atomic force microscopy (AFM) is widely used in liquid environments, where true atomic resolution at the solid-liquid interface can now be routinely achieved. It is generally expected that AFM operation in more viscous environments results in an increased noise contribution from the thermal motion of the cantilever, thereby reducing the signal-to-noise ratio (SNR). Thus, viscous fluids such as ionic and organic liquids have been generally avoided for high-resolution AFM studies despite their relevance to, e.g. energy applications. Here, we investigate the thermal noise limitations of dynamic AFM operation in both low and high viscosity environments theoretically, deriving expressions for the amplitude, phase and frequency noise resulting from the thermal motion of the cantilever, thereby defining the performance limits of amplitude modulation, phase modulation and frequency modulation AFM. We show that the assumption of a reduced SNR in viscous environments is not inherent to the technique and demonstrate that SNR values comparable to ultra-high vacuum systems can be obtained in high viscosity environments under certain conditions. Finally, we have obtained true atomic resolution images of highly ordered pyrolytic graphite and mica surfaces, thus revealing the potential of high-resolution imaging in high viscosity environments.

  8. The Intra-cluster medium: recent results and future prospects

    NASA Astrophysics Data System (ADS)

    Molendi, Silvano

    2010-07-01

    This comunication is divided in two parts: in the first I present some recent observational results obtained by my group; in the second I list what I consider to be the top priorities in terms of X-ray instrumentation for cluster science and compare them with missions currently under development.

  9. Comparative Studies on Dyeability with Direct, Acid and Reactive Dyes after Chemical Modification of Jute with Mixed Amino Acids Obtained from Extract of Waste Soya Bean Seeds

    NASA Astrophysics Data System (ADS)

    Bhaumik, Nilendu Sekhar; Konar, Adwaita; Roy, Alok Nath; Samanta, Ashis Kumar

    2017-12-01

    Jute fabric was treated with mixed natural amino acids obtained from waste soya bean seed extract for chemical modification of jute for its cataionization and to enhance its dyeability with anionic dyes (like direct, reactive and acid dye) as well enabling soya modified jute for salt free dyeing with anionic reactive dyes maintaining its eco-friendliness. Colour interaction parameters including surface colour strength were assessed and compared for both bleached and soya-modified jute fabric for reactive dyeing and compared with direct and acid dye. Improvement in K/S value (surface colour strength) was observed for soya-modified jute even in absence of salt applied in dye bath for reactive dyes as well as for direct and acid dyes. In addition, reactive dye also shows good dyeability even in acid bath in salt free conditions. Colour fastness to wash was evaluated for bleached and soya-modified jute fabric after dyeing with direct, acid and reactive dyes are reported. Treatment of jute with soya-extracted mixed natural amino acids showed anchoring of some amino/aldemine groups on jute cellulosic polymer evidenced from Fourier Transform Infra-Red (FTIR) Spectroscopy. This amino or aldemine group incorporation in bleached jute causes its cationization and hence when dyed in acid bath for reactive dye (instead of conventional alkali bath) showed dye uptake for reactive dyes. Study of surface morphology by Scanning Electron Microscopy (SEM) of said soya-modified jute as compared to bleached jute was studied and reported.

  10. Using the Viking biology experimental results to obtain chemical information about Martian regolith

    NASA Technical Reports Server (NTRS)

    Plumb, Robert C.

    1992-01-01

    Although initially formulated as biology experiments, most of the results produced by the Viking Labeled Release (LR), Gas Exchange (GEX), and Pyrolytic Release (PR) experiments have been reproduced by chemical means. The experiments do not need more study as 'biological' phenomena, but they do deserve much more careful consideration from a chemical viewpoint. They are the only 'wet-chemical' experiments that scientists have performed on another planet, but they have not found very general use as sources of scientific information. There is a large set of potentially useful chemical observations, e.g., the three resolvable and precisely measured kinetic components of the release of C-14-labeled gases, the thermal sensitivity and magnitudes of the oxidation reaction(s) of the LR experiments, the kinetics and magnitude of the O2 and CO2 release of the GEX experiments, the thermal sensitivity of the GEX results, the differences between the thermal sensitivity of the GEX and the thermal sensitivity of the LR responses, and the kinetics and magnitudes of the LR successive injection reabsorption effect. It should be possible to test many chemical aspects of hypothetical martian phenomena in experiments using the biology experimental configurations and derive much valuable information by comparisons with the Viking observations.

  11. Ion cyclotron instability at Io: Hybrid simulation results compared to in situ observations

    NASA Astrophysics Data System (ADS)

    Šebek, Ondřej; Trávníček, Pavel M.; Walker, Raymond J.; Hellinger, Petr

    2016-08-01

    We present analysis of global three-dimensional hybrid simulations of Io's interaction with Jovian magnetospheric plasma. We apply a single-species model with simplified neutral-plasma chemistry and downscale Io in order to resolve the ion kinetic scales. We consider charge exchange, electron impact ionization, and photoionization by using variable rates of these processes to investigate their impact. Our results are in a good qualitative agreement with the in situ magnetic field measurements for five Galileo flybys around Io. The hybrid model describes ion kinetics self-consistently. This allows us to assess the distribution of temperature anisotropies around Io and thereby determine the possible triggering mechanism for waves observed near Io. We compare simulated dynamic spectra of magnetic fluctuations with in situ observations made by Galileo. Our results are consistent with both the spatial distribution and local amplitude of magnetic fluctuations found in the observations. Cyclotron waves, triggered probably by the growth of ion cyclotron instability, are observed mainly downstream of Io and on the flanks in regions farther from Io where the ion pickup rate is relatively low. Growth of the ion cyclotron instability is governed mainly by the charge exchange rate.

  12. Comparative study of the microstructural and magnetic properties of fly ashes obtained from different thermal power plants in West Bengal, India.

    PubMed

    Bhattacharjee, Ashis; Mandal, Haradhan; Roy, Madhusudan; Kusz, Joachim; Hofmeister, Wolfgang

    2013-10-01

    This paper deals with the physical nature of the fly ashes obtained from two thermal power plants, situated in West Bengal, India. The fly ash samples are characterized by using comprehensive techniques with an emphasis on their ultrafine nature. The particle sizes of the samples are estimated using scanning electron microcopy (SEM) and found to lie within 0.18-5.90 μm. For morphology and compositional analysis, we also use SEM coupled with energy dispersive X-ray spectrometry. From X-ray study of the fly ashes the nature of conglomeration is seen to be crystalline, and the major components are mullite (Al6Si2O13) and quartz (SiO2). The magnetic measurement of the fly ash samples was carried out by SQUID magnetometer. (57)Fe Mössbauer spectra are obtained using a conventional constant-acceleration spectrometer with a (57)Co/Rh Mössbauer source. The hyperfine parameters obtained, in general, support the findings as made from XRD analysis and provide a quantitative measure of different iron ions present in the samples. The paper presents experimental data on the physical aspects of the fly ash samples of the thermal power plants which comprise coarse, fine, and ultrafine magnetic particulate materials and attempts to provide an exhaustive analysis.

  13. Comparison of Thellier-type and multispecimen absolute paleointensities obtained on Miocene to historical lava flows from Lanzarote (Canary Islands, Spain)

    NASA Astrophysics Data System (ADS)

    Calvo-Rathert, M.; Morales, J.; Carrancho, Á.; Gogichaishvili, A.

    2015-12-01

    A paleomagnetic, rock-magnetic and paleointensity study has been carried out on 16 Miocene, Pleistocene, Quaternary and historical lava flows from Lanzarote (Canary Islands, Spain) with two main goals: (i) Compare paleointensity results obtained with two different techniques (Thellier-type and multispecimen) and (ii) obtain new paleointensity data. Initial rock-magnetic experiments on selected samples from each site were carried out to find out the carriers of remanence and to determine their thermal stability and grain size. They included the measurement of thermomagnetic curves, hysteresis parameters and IRM acquisition curves. Mostly reversible but also non-reversible curves were recorded in thermomagnetic experiments, with low-Ti titanomagnetite being the main carrier of remanence in most studied flows. Paleomagnetic analysis showed in most cases a single component and a characteristic component could be determined in 15 flows, all displaying normal-polarity. 83 samples from 13 flows were chosen for paleointensity experiments. In order to compare paleointensity results from exactly the same samples, they were cut into smaller specimens so that in each case a specimen was available to be used for a Thellier-type paleointensity determination, another one for a multispecimen paleointensity experiment and another one for rock-magnetic experiments. Thermomagnetic curves could be therefore measured on all samples subjected to paleointensity experiments. Thellier-type paleointensity determinations were performed with the Coe method between room temperature and 581°C on small (0.9 cm diameter and 1 to 2.5 cm length) specimens. After heating, samples were left cooling down naturally during several hours. Multispecimen paleointensity determinations were carried out using the method of Dekkers and Böhnel. The aforementioned sub-samples were cut into 8 specimens and pressed into salt pellets in order to obtain standard cylindrical specimens. A set of eight experiments

  14. Method for obtaining electron energy-density functions from Langmuir-probe data using a card-programmable calculator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Longhurst, G.R.

    This paper presents a method for obtaining electron energy density functions from Langmuir probe data taken in cool, dense plasmas where thin-sheath criteria apply and where magnetic effects are not severe. Noise is filtered out by using regression of orthogonal polynomials. The method requires only a programmable calculator (TI-59 or equivalent) to implement and can be used for the most general, nonequilibrium electron energy distribution plasmas. Data from a mercury ion source analyzed using this method are presented and compared with results for the same data using standard numerical techniques.

  15. Effect of thermal treatment on TL response of CaSO₄:Dy obtained using a new preparation method.

    PubMed

    González, P R; Cruz-Zaragoza, E; Furetta, C; Azorín, J; Alcántara, B C

    2013-05-01

    We report the effect of thermal treatment on thermoluminescent (TL) sensitivity property of CaSO4:Dy obtained by a new preparation method at Instituto Nacional de Investigaciones Nucleares (ININ) of Mexico. Samples of phosphor powder were subjected to different thermal treatments respectively at 773, 873, 973 and 1,173K for 1h and then irradiated from 0.1 to 1,000 Gy gamma doses. Low energy dependence was analyzed too by irradiating with X-rays in the range of 16-145 keV. The results were normalized to the energy (1,252 keV) of (60)Co and they were compared with those obtained using the commercial dosimeters TLD-100. Also the kinetic parameters were determined by deconvolution of glow curve. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Comparing the similarity of responses received from studies in Amazon's Mechanical Turk to studies conducted online and with direct recruitment.

    PubMed

    Bartneck, Christoph; Duenser, Andreas; Moltchanova, Elena; Zawieska, Karolina

    2015-01-01

    Computer and internet based questionnaires have become a standard tool in Human-Computer Interaction research and other related fields, such as psychology and sociology. Amazon's Mechanical Turk (AMT) service is a new method of recruiting participants and conducting certain types of experiments. This study compares whether participants recruited through AMT give different responses than participants recruited through an online forum or recruited directly on a university campus. Moreover, we compare whether a study conducted within AMT results in different responses compared to a study for which participants are recruited through AMT but which is conducted using an external online questionnaire service. The results of this study show that there is a statistical difference between results obtained from participants recruited through AMT compared to the results from the participant recruited on campus or through online forums. We do, however, argue that this difference is so small that it has no practical consequence. There was no significant difference between running the study within AMT compared to running it with an online questionnaire service. There was no significant difference between results obtained directly from within AMT compared to results obtained in the campus and online forum condition. This may suggest that AMT is a viable and economical option for recruiting participants and for conducting studies as setting up and running a study with AMT generally requires less effort and time compared to other frequently used methods. We discuss our findings as well as limitations of using AMT for empirical studies.

  17. Comparative hybrid and digital simulation studies of the behaviour of a wind generator equipped with a static frequency converter

    NASA Astrophysics Data System (ADS)

    Dube, B.; Lefebvre, S.; Perocheau, A.; Nakra, H. L.

    1988-01-01

    This paper describes the comparative results obtained from digital and hybrid simulation studies on a variable speed wind generator interconnected to the utility grid. The wind generator is a vertical-axis Darrieus type coupled to a synchronous machine by a gear-box; the synchronous machine is connected to the AC utility grid through a static frequency converter. Digital simulation results have been obtained using CSMP software; these results are compared with those obtained from a real-time hybrid simulator that in turn uses a part of the IREQ HVDC simulator. The agreement between hybrid and digital simulation results is generally good. The results demonstrate that the digital simulation reproduces the dynamic behavior of the system in a satisfactory manner and thus constitutes a valid tool for the design of the control systems of the wind generator.

  18. Comparative Study of Green Sub- and Supercritical Processes to Obtain Carnosic Acid and Carnosol-Enriched Rosemary Extracts with in Vitro Anti-Proliferative Activity on Colon Cancer Cells.

    PubMed

    Sánchez-Camargo, Andrea Del Pilar; García-Cañas, Virginia; Herrero, Miguel; Cifuentes, Alejandro; Ibáñez, Elena

    2016-12-07

    In the present work, four green processes have been compared to evaluate their potential to obtain rosemary extracts with in vitro anti-proliferative activity against two colon cancer cell lines (HT-29 and HCT116). The processes, carried out under optimal conditions, were: (1) pressurized liquid extraction (PLE, using an hydroalcoholic mixture as solvent) at lab-scale; (2) Single-step supercritical fluid extraction (SFE) at pilot scale; (3) Intensified two-step sequential SFE at pilot scale; (4) Integrated PLE plus supercritical antisolvent fractionation (SAF) at pilot scale. Although higher extraction yields were achieved by using PLE (38.46% dry weight), this extract provided the lowest anti-proliferative activity with no observed cytotoxic effects at the assayed concentrations. On the other hand, extracts obtained using the PLE + SAF process provided the most active rosemary extracts against both colon cancer cell lines, with LC 50 ranging from 11.2 to 12.4 µg/mL and from 21.8 to 31.9 µg/mL for HCT116 and HT-29, respectively. In general, active rosemary extracts were characterized by containing carnosic acid (CA) and carnosol (CS) at concentrations above 263.7 and 33.9 mg/g extract, respectively. Some distinct compounds have been identified in the SAF extracts (rosmaridiphenol and safficinolide), suggesting their possible role as additional contributors to the observed strong anti-proliferative activity of CA and CS in SAF extracts.

  19. 48 CFR 53.107 - Obtaining forms.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 2 2012-10-01 2012-10-01 false Obtaining forms. 53.107 Section 53.107 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS General 53.107 Obtaining forms. (a) Executive agencies shall obtain standard and...

  20. 48 CFR 53.107 - Obtaining forms.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 2 2013-10-01 2013-10-01 false Obtaining forms. 53.107 Section 53.107 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS General 53.107 Obtaining forms. (a) Executive agencies shall obtain standard and...

  1. 48 CFR 53.107 - Obtaining forms.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Obtaining forms. 53.107 Section 53.107 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS General 53.107 Obtaining forms. (a) Executive agencies shall obtain standard and...

  2. 48 CFR 53.107 - Obtaining forms.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 2 2011-10-01 2011-10-01 false Obtaining forms. 53.107 Section 53.107 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS General 53.107 Obtaining forms. (a) Executive agencies shall obtain standard and...

  3. 48 CFR 53.107 - Obtaining forms.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 2 2014-10-01 2014-10-01 false Obtaining forms. 53.107 Section 53.107 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS General 53.107 Obtaining forms. (a) Executive agencies shall obtain standard and...

  4. Results of Radiocarbon Dating of Holocene Deposits from the Sea of Azov

    NASA Astrophysics Data System (ADS)

    Matishov, G. G.; Kovaleva, G. V.; Arslanov, Kh. A.; Dyuzhova, K. V.; Polshin, V. V.; Zolotareva, A. E.

    2018-04-01

    New data on the absolute age of Quaternary bottom deposits from the Sea of Azov based on the results of radiocarbon analysis (14C) are presented. Overall, 67 radiocarbon dating of bottom deposits of New and Ancient Azov Ages were obtained. The thickness of sediments of the New Azov Age and their distribution over different areas of the Sea of Azov was determined during the study; the results obtained were compared with the reference data available. An integrated approach to the study of deposits, based on the combination of the biostratigraphy methods and the results of absolute age dating, was applied.

  5. Comparison of bacterial counts obtained from naturally contaminated foods by means of Stomacher and blender.

    PubMed

    Purvis, U; Sharpe, A N; Bergener, D M; Lachapelle, G; Milling, M; Spiring, F

    1987-01-01

    Four Regional Health Protection Branch laboratories each compared aerobic colony counts obtained after "stomaching" and blending, for a minimum of 10 samples in each of the seven food groups: dry pastas; chocolate and cocoa powders; frozen entrees (macaroni and cheese, chow mein, chop suey, fried rice, seafood casseroles, and Salisbury steak); nonfat dry milk; shrimp and crabmeats; spices; and breakfast sausages. Overall, counts obtained after using the Stomacher were equivalent to or higher than counts obtained after using the blender in 73% of the comparisons (alpha = 0.05). Where differences existed, counts obtained after using the Stomacher tended to be higher than counts obtained after using the blender from milk powder and lower from sausage. Aerobic colony counts from these foods are not unacceptably biased when obtained by Stomacher.

  6. [Using neural networks based template matching method to obtain redshifts of normal galaxies].

    PubMed

    Xu, Xin; Luo, A-li; Wu, Fu-chao; Zhao, Yong-heng

    2005-06-01

    Galaxies can be divided into two classes: normal galaxy (NG) and active galaxy (AG). In order to determine NG redshifts, an automatic effective method is proposed in this paper, which consists of the following three main steps: (1) From the template of normal galaxy, the two sets of samples are simulated, one with the redshift of 0.0-0.3, the other of 0.3-0.5, then the PCA is used to extract the main components, and train samples are projected to the main component subspace to obtain characteristic spectra. (2) The characteristic spectra are used to train a Probabilistic Neural Network to obtain a Bayes classifier. (3) An unknown real NG spectrum is first inputted to this Bayes classifier to determine the possible range of redshift, then the template matching is invoked to locate the redshift value within the estimated range. Compared with the traditional template matching technique with an unconstrained range, our proposed method not only halves the computational load, but also increases the estimation accuracy. As a result, the proposed method is particularly useful for automatic spectrum processing produced from a large-scale sky survey project.

  7. Survival of modern knee tumor megaprostheses: failures, functional results, and a comparative statistical analysis.

    PubMed

    Pala, Elisa; Trovarelli, Giulia; Calabrò, Teresa; Angelini, Andrea; Abati, Caterina N; Ruggieri, Pietro

    2015-03-01

    Modular megaprostheses are now the most common method of reconstruction after segmental resection of the long bones in the lower extremities. Previous studies reported variable outcome and failure rates after knee megaprosthetic reconstructions. The objectives of this study were to analyze the results of a modular tumor prosthesis after resection of bone tumor around the knee with respect to (1) survivorship; (2) failure rate; (3) comparative survivorship against different sites of reconstructions and of primary and revision implants; and (4) functional results on the Musculoskeletal Tumor Society (MSTS) scoring system. Between 2003 and 2010, 247 rotating-hinge Global Modular Reconstruction System (GMRS) knee prostheses were implanted in our institute for malignant and aggressive benign tumors. During this time, that group represented 23% of the patients who had oncologic megaprosthesis reconstruction about the knee after resection of primary or metastatic bone tumors (247 of 1086 patients). In the other 77% of cases we used other types of oncologic prostheses. Before 2003 we used the older Howmedica Modular Resection System and Kotz Modular Femur/Tibia Replacement from 2003 we used mostly the GMRS but we continued to use the HMRS in some cases such as patients with poor prognoses, elderly patients, or metastatic patients. Sites included 187 distal femurs and 60 proximal tibias. Causes of megaprosthesis failure were classified according to Henderson et al. in five types: Type 1 (soft tissue failure), Type 2 (aseptic loosening), Type 3 (structural failure), Type 4 (infection), and Type 5 (tumor progression). Followup was at a minimum oncologic followup of 2 years (mean, 4 years; range, 2-8 years). Kaplan-Meier actuarial curves of implant survival to major failures were done. Functional results were analyzed according to the MSTS II system; 223 of the 247 were available for functional scoring (81%). At latest followup, among 175 treated patients for primary

  8. Towards routine determination of focal mechanisms obtained from first motion P-wave arrivals

    NASA Astrophysics Data System (ADS)

    Lentas, K.

    2018-03-01

    The Bulletin of the International Seismological Centre (ISC) contains information on earthquake mechanisms collected from many different sources including national and global agencies, resulting in a satisfactory coverage over a wide magnitude range (M ˜2-9). Nevertheless, there are still a vast number of earthquakes with no reported source mechanisms especially for magnitudes up to 5. This study investigates the possibility of calculating earthquake focal mechanisms in a routine and systematic way based on P-wave first motion polarities. Any available parametric data in the ISC database is being used, as well as auto-picked polarities from waveform data up to teleseismic epicentral distances (90°) for stations that are not reported to the ISC. The determination of the earthquake mechanisms is carried out with a modified version of the HASH algorithm that is compatible with a wide range of epicentral distances and takes into account the ellipsoids defined by the ISC location errors, and the Earth's structure uncertainties. Initially, benchmark tests for a set of ISC reviewed earthquakes (mb > 4.5) are carried out and the HASH mechanism classification scheme is used to define the mechanism quality. Focal mechanisms of quality A, B and C with an azimuthal gap up to 90° compare well to the benchmark mechanisms. Nevertheless, the majority of the obtained mechanisms fall into class D as a result of limited polarity data from stations in local/regional epicentral distances. Specifically, the computation of the minimum rotation angle between the obtained mechanisms and the benchmarks, reveals that 41 per cent of the examined earthquakes show rotation angles up to 35°. Finally, the current technique is applied to a small set of earthquakes from the reviewed ISC bulletin where 62 earthquakes, with no previously reported source mechanisms, are successfully obtained.

  9. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    PubMed

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  10. Innovative plasticized alginate obtained by thermo-mechanical mixing: Effect of different biobased polyols systems.

    PubMed

    Gao, Chengcheng; Pollet, Eric; Avérous, Luc

    2017-02-10

    Plasticized alginate films with different biobased polyols (glycerol and sorbitol) and their mixtures were successfully prepared by thermo-mechanical mixing instead of the usual casting-evaporation procedure. The microstructure and properties of the different plasticized alginate formulations were investigated by SEM, FTIR, XRD, DMTA and uniaxial tensile tests. SEM and XRD results showed that native alginate particles were largely destructured with the plasticizers (polyols and water), under a thermo-mechanical input. With increasing amount of plasticizers, the samples showed enhanced homogeneity while their thermal and mechanical properties decreased. Compared to sorbitol, glycerol resulted in alginate films with a higher flexibility due to its better plasticization efficiency resulting from its smaller size and higher hydrophilic character. Glycerol and sorbitol mixtures seemed to be an optimum to obtain the best properties. This work showed that thermo-mechanical mixing is a promising method to produce, at large scale, plasticized alginate-based films with improved properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Comparative spectral analysis of veterinary powder product by continuous wavelet and derivative transforms

    NASA Astrophysics Data System (ADS)

    Dinç, Erdal; Kanbur, Murat; Baleanu, Dumitru

    2007-10-01

    Comparative simultaneous determination of chlortetracycline and benzocaine in the commercial veterinary powder product was carried out by continuous wavelet transform (CWT) and classical derivative transform (or classical derivative spectrophotometry). In this quantitative spectral analysis, two proposed analytical methods do not require any chemical separation process. In the first step, several wavelet families were tested to find an optimal CWT for the overlapping signal processing of the analyzed compounds. Subsequently, we observed that the coiflets (COIF-CWT) method with dilation parameter, a = 400, gives suitable results for this analytical application. For a comparison, the classical derivative spectrophotometry (CDS) approach was also applied to the simultaneous quantitative resolution of the same analytical problem. Calibration functions were obtained by measuring the transform amplitudes corresponding to zero-crossing points for both CWT and CDS methods. The utility of these two analytical approaches were verified by analyzing various synthetic mixtures consisting of chlortetracycline and benzocaine and they were applied to the real samples consisting of veterinary powder formulation. The experimental results obtained from the COIF-CWT approach were statistically compared with those obtained by classical derivative spectrophotometry and successful results were reported.

  12. Heavy flavor results at RHIC - A comparative overview

    DOE PAGES

    Dong, Xin

    2012-01-01

    I review the latest heavy flavor measurements at RHIC experiments. Measurements from RHIC together with preliminary results from LHC offer us an opportunity to systematically study the sQGP medium properties. In the end, I will outlook a prospective future on precision heavy flavor measurements with detector upgrades at RHIC.

  13. In vivo organ mass of Korean adults obtained from whole-body magnetic resonance data.

    PubMed

    Park, S; Lee, J K; Kim, J I; Lee, Y J; Lim, Y K; Kim, C S; Lee, C

    2006-01-01

    In vivo organ mass of the Korean adult, male and female were presented for the purpose of radiation protection. A total of 121 healthy volunteers (66 males and 55 females), whose body dimensions were close to that of average Korean adults, were recruited for this study. Whole-body magnetic resonance (MR) images were obtained, and contours of 15 organs (brain, eye, gall bladder, heart, kidney, liver, lung, pancreas, stomach, spleen, testes, thymus, thyroid, urinary bladder and uterus) and 9 bones (femur, tibia + fibula, humerus, radius + ulna, pelvis, cervical spine, thoracic and lumber spine, skull and clavicle) were segmented for organ volume rendering by anatomists using commercial software. Organ and bone masses were calculated by multiplying the Asian reference densities of the corresponding organs and bones by the measured volumes. The resulting organ and bone masses were compared with those of the International Commission of Radiological Protection (ICRP) and the Asian reference data. Significantly large standard deviation was shown in the moving organs of the respiratory and circulatory systems and in the alimentary and urogenital organs that are variable in volume in a single person. Gall bladder and pancreas showed unique Korean organ masses compared with those of ICRP and the Asian reference adults. Different from anatomical data based on autopsy, the in vivo volume and mass in this study can more exactly describe the organ volume of a living human subject for radiation protection. A larger sample size would be required for obtaining statistically more reliable results. It is also needed to establish the reference organ mass of younger age groups for which it is difficult to recruit volunteers and to immobilise the subjects for long-time MR scanning. At present, the data from this study will contribute to the establishment of a Korean reference database.

  14. Metallosupramolecular Architectures Obtained from Poly-N-heterocyclic Carbene Ligands.

    PubMed

    Sinha, Narayan; Hahn, F Ekkehardt

    2017-09-19

    photochemically induced single or double [2 + 2] cycloaddition to form dinuclear tetracarbene complexes featuring cyclobutane units. Even three-dimensional cage-like structures can be prepared by this postsynthetic strategy. Cylinder-like trinuclear, tetranuclear, and hexanuclear (M = Ag I , Au I , Cu I , Hg II , Pd II ) complexes have been obtained from benzene-bridged tris-, tetrakis-, or hexakis-NHC ligands. These complexes resemble polynuclear assemblies obtained from related polydentate Werner-type ligands. Contrary to the Werner-type complexes, cylinder-like assemblies with three, four, or six silver(I) ions sandwiched in between two tris-, tetrakis-, or hexakis-NHC ligands undergo a facile transmetalation reaction to give the complexes featuring more stable M-C NHC bonds, normally with retention of the metallosupramolecular structure. This unique behavior of NHC-Ag + complexes allows the prepration of assemblies containing various metals from the poly-NHC silver(I) assemblies. Narcissistic self-sorting phenomena have also been observed for mixtures of selected poly-NHC ligands and silver(I) ions. Even a very early type of metallosupramolecular assembly, the tetranuclear molecular square, can be prepared from four bridging dicarbene ligands and four transition metal ions either by a stepwise assembly or by a single-step protocol. At this point, it appears that procedures for the synthesis of metallosupramolecular assemblies using polydentate Werner-type ligands and metal ions can be transferred to organometallic chemistry by using suitable poly-NHC ligands. The resulting structures feature stable M-C NHC bonds (with the exception of the labile C NHC -Ag + bond) when compared to M-N/M-O bonds in classical Werner-type complexes. The generally good solubility of the compounds and the presence of the often catalytically active {M(NHC) n } moiety make organometallic supramolecular complexes a promising new class of molecular hosts for catalytic transformations and encapsulation

  15. [Effect of a multidisciplinar protocol on the clinical results obtained after bariatric surgery].

    PubMed

    Cánovas Gaillemin, B; Sastre Martos, J; Moreno Segura, G; Llamazares Iglesias, O; Familiar Casado, C; Abad de Castro, S; López Pardo, R; Sánchez-Cabezudo Muñoz, M A

    2011-01-01

    Bariatric surgery has been shown to be an effective therapy for weight loss in patients with severe obesity, and the implementation of a multidisciplinar management protocol is recommended. To assess the usefulness of the implementation of a management protocol in obesity surgery based on the Spanish Consensus Document of the SEEDO. Retrospective comparative study of the outcomes in patients previously operated (51 patients) and after the implementation of the protocol (66 patients). The following data were gathered: anthropometry, pre-and post-surgery comorbidities, post-surgical nutritional and surgical complications, validated Quality of Life questionnaire, and dietary habits. Withdrawals (l7.6%) and alcoholism (5.8%) were higher in patients pre- versus post-implementation of the protocol (4.5% vs. 3%, respectively), the differences being statistically significant. The mortality rate was 2% in the pre-protocol group and 0% in the postprotocol group. The dietary habits were better in the post-protocol group, the pre-protocol group presenting a higher percentage of feeding-behavior disorders (5.1%) although not reaching a statistical significance. The improvement in quality of life was higher in the post-protocol group for all items, but only reaching statistical significance in sexual activity (p = 0.004). In the pre-protocol group, 70.5% of the patients had more than one nutritional complication vs. 32.8% in the post-protocol group (p < 0.05). There were no differences regarding the percentage of weight in excess lost at two years (> 50% in 81.3% in the pre-protocol group vs. 74.8% in the pos-protocol group) or the comorbidities. Bariatric surgery achieves excellent outcomes in weight loss, comorbidities, and quality of life, but presents nutritional, surgical, and psychiatric complications that require a protocol-based and multidisciplinary approach. Our protocol improves the outcomes regarding the withdrawal rates, feeding-behavior disorders, dietary habits

  16. Comparative study on direct burning of oil shale and coal

    NASA Astrophysics Data System (ADS)

    Hammad, Ahmad; Al Asfar, Jamil

    2017-07-01

    A comparative study of the direct burning processes of oil shale and coal in a circulating fluidized bed (CFB) was done in this study using ANSYS Fluent software to solve numerically the governing equations of continuity, momentum, energy and mass diffusion using finite volume method. The model was built based on an existing experimental combustion burner unit. The model was validated by comparing the theoretical results of oil shale with proved experimental results from the combustion unit. It was found that the temperature contours of the combustion process showed that the adiabatic flame temperature was 1080 K for oil shale compared with 2260 K for coal, while the obtained experimental results of temperatures at various locations of burner during the direct burning of oil shale showed that the maximum temperature reached 962 K for oil shale. These results were used in economic and environmental analysis which show that oil shale may be used as alternative fuel for coal in cement industry in Jordan.

  17. Obtaining reimbursement in France and Italy for new diabetes products.

    PubMed

    Schaefer, Elmar; Schnell, Gerald; Sonsalla, Jessica

    2015-01-01

    Manufacturers launching next-generation or innovative medical devices in Europe face a very heterogeneous reimbursement landscape, with each country having its own pathways, timing, requirements and success factors. We selected 2 markets for a deeper look into the reimbursement landscape: France, representing a country with central decision making with defined processes, and Italy, which delegates reimbursement decisions to the regional level, resulting in a less transparent approach to reimbursement. Based on our experience in working on various new product launches and analyzing recent reimbursement decisions, we found that payers in both countries do not reward improved next-generation products with incremental reimbursement. Looking at innovations, we observe that manufacturers face a challenging and lengthy process to obtain reimbursement. In addition, requirements and key success factors differ by country: In France, comparative clinical evidence and budget impact very much drive reimbursement decisions in terms of pricing and restrictions, whereas in Italy, regional key opinion leader (KOL) support and additional local observational data are key. © 2015 Diabetes Technology Society.

  18. Comparison of urine and bladder or urethral mucosal biopsy culture obtained by transurethral cystoscopy in dogs with chronic lower urinary tract disease: 41 cases (2002 to 2011).

    PubMed

    Sycamore, K F; Poorbaugh, V R; Pullin, S S; Ward, C R

    2014-07-01

    To compare aerobic bacterial culture of urine to cystoscopically obtained mucosal biopsies of the lower urinary tract in dogs. Retrospective review of case records from dogs that had transurethral cystoscopy at a veterinary teaching hospital between 2002 and 2011. Dogs that had culture results from cystocentesis obtained urine and transurethral cystoscopically obtained mucosal samples were included in the study. Pathogens identified were compared between sampling methods. Forty dogs underwent transurethral cystoscopy for lower urinary tract disease on 41 occasions. There was significant (P = 0 · 0003) agreement between urine and mucosal biopsy cultures. Both cultures were negative in 66% and positive in 17% of dogs. There was a 17% disagreement between the sampling methods. Although not statistically significant, more mucosal samples than urine cultures were positive for Escherichia coli. There was a good agreement between pathogen identification from urine and lower urinary tract mucosal cultures. These results do not support the utilisation of transurethral cystoscopy to obtain biopsy samples for culture in dogs with urinary tract infection and positive urine culture. Individual cases with possible chronic urinary tract infection and negative urine culture may benefit from transurethral cystoscopy to obtain biopsies for culture. © 2014 British Small Animal Veterinary Association.

  19. Quantitative phase analysis and microstructure characterization of magnetite nanocrystals obtained by microwave assisted non-hydrolytic sol–gel synthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sciancalepore, Corrado, E-mail: corrado.sciancalepore@unimore.it; Bondioli, Federica; INSTM Consortium, Via G. Giusti 9, 51121 Firenze

    2015-02-15

    An innovative preparation procedure, based on microwave assisted non-hydrolytic sol–gel synthesis, to obtain spherical magnetite nanoparticles was reported together with a detailed quantitative phase analysis and microstructure characterization of the synthetic products. The nanoparticle growth was analyzed as a function of the synthesis time and was described in terms of crystallization degree employing the Rietveld method on the magnetic nanostructured system for the determination of the amorphous content using hematite as internal standard. Product crystallinity increases as the microwave thermal treatment is increased and reaches very high percentages for synthesis times longer than 1 h. Microstructural evolution of nanocrystals wasmore » followed by the integral breadth methods to obtain information on the crystallite size-strain distribution. The results of diffraction line profile analysis were compared with nanoparticle grain distribution estimated by dimensional analysis of the transmission electron microscopy (TEM) images. A variation both in the average grain size and in the distribution of the coherently diffraction domains is evidenced, allowing to suppose a relationship between the two quantities. The traditional integral breadth methods have proven to be valid for a rapid assessment of the diffraction line broadening effects in the above-mentioned nanostructured systems and the basic assumption for the correct use of these methods are discussed as well. - Highlights: • Fe{sub 3}O{sub 4} nanocrystals were obtained by MW-assisted non-hydrolytic sol–gel synthesis. • Quantitative phase analysis revealed that crystallinity up to 95% was reached. • The strategy of Rietveld refinements was discussed in details. • Dimensional analysis showed nanoparticles ranging from 4 to 8 nm. • Results of integral breadth methods were compared with microscopic analysis.« less

  20. Preliminary Results Obtained in Integrated Safety Analysis of NASA Aviation Safety Program Technologies

    NASA Technical Reports Server (NTRS)

    Reveley, Mary S.

    2003-01-01

    The goal of the NASA Aviation Safety Program (AvSP) is to develop and demonstrate technologies that contribute to a reduction in the aviation fatal accident rate by a factor of 5 by the year 2007 and by a factor of 10 by the year 2022. Integrated safety analysis of day-to-day operations and risks within those operations will provide an understanding of the Aviation Safety Program portfolio. Safety benefits analyses are currently being conducted. Preliminary results for the Synthetic Vision Systems (SVS) and Weather Accident Prevention (WxAP) projects of the AvSP have been completed by the Logistics Management Institute under a contract with the NASA Glenn Research Center. These analyses include both a reliability analysis and a computer simulation model. The integrated safety analysis method comprises two principal components: a reliability model and a simulation model. In the reliability model, the results indicate how different technologies and systems will perform in normal, degraded, and failed modes of operation. In the simulation, an operational scenario is modeled. The primary purpose of the SVS project is to improve safety by providing visual-flightlike situation awareness during instrument conditions. The current analyses are an estimate of the benefits of SVS in avoiding controlled flight into terrain. The scenario modeled has an aircraft flying directly toward a terrain feature. When the flight crew determines that the aircraft is headed toward an obstruction, the aircraft executes a level turn at speed. The simulation is ended when the aircraft completes the turn.

  1. Compared to Palliative Care, Working in Intensive Care More than Doubles the Chances of Burnout: Results from a Nationwide Comparative Study

    PubMed Central

    Teixeira, Carla Margarida; Carvalho, Ana Sofia; Hernández-Marrero, Pablo

    2016-01-01

    Introduction Professionals working in intensive and palliative care units, hence caring for patients at the end-of-life, are at risk of developing burnout. Workplace conditions are determinant factors to develop this syndrome among professionals providing end-of-life care. Objectives To identify and compare burnout levels between professionals working in intensive and palliative care units; and to assess which workplace experiences are associated with burnout. Methods A nationwide, multicentre quantitative comparative survey study was conducted in Portugal using the following instruments: Maslach Burnout Inventory–Human Services Survey, Questionnaire of workplace experiences and ethical decisions, and Questionnaire of socio-demographic and professional characteristics. A total of 355 professionals from 10 intensive care and 9 palliative care units participated in the survey. A series of univariate and multivariate logistic regression analyses were performed; odds ratio sidelong with 95% confidence intervals were calculated. Results 27% of the professionals exhibited burnout. This was more frequent in intensive care units (OR = 2.525, 95% CI: 1.025–6.221, p = .006). Univariate regression analyses showed that higher burnout levels were significantly associated with conflicts, decisions to withhold/withdraw treatment, and implementing palliative sedation. When controlling for socio-demographic and educational characteristics, and setting (intensive care units versus palliative care units), higher burnout levels were significantly and positively associated with experiencing conflicts in the workplace. Having post-graduate education in intensive/palliative care was significantly but inversely associated to higher burnout levels. Conclusions Compared to palliative care, working in intensive care units more than doubled the likelihood of exhibiting burnout. Experiencing conflicts (e.g., with patients and/or families, intra and/or inter-teams) was the most significant

  2. Organizational Culture at High Schools in TRNC: A Comparative Case Study

    ERIC Educational Resources Information Center

    Silman, Fatos; Ozmatyatli, Icim Ozenli; Birol, Cem; Caglar, Mehmet

    2012-01-01

    This study was conducted to compare the organizational culture in two TRNC schools by using influencing factors of metaphors, physical environment, values, norms, rituals, language, legends and reward systems. To obtain data, a triangulation of participant interviews, observations and written sources were used. Results appear to display that the…

  3. Technical and technological solution for vegetal bio-stimulants obtaining

    NASA Astrophysics Data System (ADS)

    Anghelache, D. G.; Diaconescu, I.; Pătraşcu, R.

    2017-08-01

    The paper presents a modern technology for bio fertilizers resulted from waste plant mass after harvesting crops Experimental products were obtained rich in nutrients, but unstable in terms of existing microorganisms. Therefore, they conducted further studies to obtaining bio fungicide herb, so in all investigations undertaken so far in the laboratory, were able to conclude that the introduction of medicinal plant extracts with fungicidal effect into the bio fertilizers obtained by degradation of plant material post-harvest can get various bio-stimulants with nourishing effect upon the plants. Following this technology the paper’s objective is to identify a flux scheme for experimental equipment which can produce as final outcome this type of bio-stimulant. Also, in this work, this equipment will be chosen and will be designed following and obeying to the request of every step of the above technology.

  4. Attractive results obtained in Mexico cementing with turbulent flow and in fracturing marginal wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1970-02-01

    The cementing with turbulent flow and the fracturing at high rates of injection have borne appreciable fruit in a gas-producing region of Mexico, known as the NE. Front District, with headquarters in Reynosa. By cementing with turbulent flow, Petroleos Mexicanos (Pemex) has increased to nearly 90% the success ratio of casing cementing. In the same general area, due to hydraulic fracturing, gas fields which before were considered marginal, have become good producers. The fracturing jobs must be well-planned and well-executed. The results in these Eocene formations show considerable variance, from good to extraordinary. The results show a low productivity ofmore » increase of 66.3% and a high productivity of 326%, following frac treatment. Graphical representations show cementing with turbulent flow; and the effect of fracturing.« less

  5. Comparative analysis of methods for concentrating venom from jellyfish Rhopilema esculentum Kishinouye

    NASA Astrophysics Data System (ADS)

    Li, Cuiping; Yu, Huahua; Feng, Jinhua; Chen, Xiaolin; Li, Pengcheng

    2009-02-01

    In this study, several methods were compared for the efficiency to concentrate venom from the tentacles of jellyfish Rhopilema esculentum Kishinouye. The results show that the methods using either freezing-dry or gel absorption to remove water to concentrate venom are not applicable due to the low concentration of the compounds dissolved. Although the recovery efficiency and the total venom obtained using the dialysis dehydration method are high, some proteins can be lost during the concentrating process. Comparing to the lyophilization method, ultrafiltration is a simple way to concentrate the compounds at high percentage but the hemolytic activities of the proteins obtained by ultrafiltration appear to be lower. Our results suggest that overall lyophilization is the best and recommended method to concentrate venom from the tentacles of jellyfish. It shows not only the high recovery efficiency for the venoms but high hemolytic activities as well.

  6. Simplest chronoscope. III. Further comparisons between reaction times obtained by meterstick versus machine.

    PubMed

    Montare, Alberto

    2013-06-01

    The three classical Donders' reaction time (RT) tasks (simple, choice, and discriminative RTs) were employed to compare reaction time scores from college students obtained by use of Montare's simplest chronoscope (meterstick) methodology to scores obtained by use of a digital-readout multi-choice reaction timer (machine). Five hypotheses were tested. Simple RT, choice RT, and discriminative RT were faster when obtained by meterstick than by machine. The meterstick method showed higher reliability than the machine method and was less variable. The meterstick method of the simplest chronoscope may help to alleviate the longstanding problems of low reliability and high variability of reaction time performances; while at the same time producing faster performance on Donders' simple, choice and discriminative RT tasks than the machine method.

  7. Long-term results of sequential vein coronary artery bypass grafting compared with totally arterial myocardial revascularization: a propensity score-matched follow-up study†.

    PubMed

    Garatti, Andrea; Castelvecchio, Serenella; Canziani, Alberto; Corain, Livio; Generali, Tommaso; Mossuto, Eugenio; Gagliardotto, Piervincenzo; Anastasia, Luigi; Salmaso, Luigi; Giacomazzi, Francesca; Menicanti, Lorenzo

    2014-12-01

    The aim of the study was to analyse the early and long-term outcomes of a consecutive series of patients who underwent sequential coronary artery bypass grafting (CABG) and to compare them with a matched population of totally arterial revascularized patients. From January 1994 to December 1996, 209 patients underwent total arterial myocardial revascularization at our institution [arterial (ART) group]. In the same period, 2097 patients underwent CABG with left internal thoracic artery on left anterior descending and great saphenous vein on the right and circumflex branches sequentially [sequential vein (SV) group]. The propensity score methodology was used to obtain risk-adjusted outcome comparisons between the two groups (209 vs 243 patients in the ART group and SV group, respectively). In-hospital mortality was 1% in the ART group and 0.4% in the SV group (P = 0.86). Mean follow-up was 14 ± 4 years. Long-term survival was comparable among the two study groups [actuarial 5- and 15-year survival rates were 97 vs 93% and 82 vs 79% in the ART group and the SV group, respectively (P = 0.29)]. At follow-up, recurrence of angina (17 vs 18%; P = 0.99), acute myocardial infarction (MI) (3 vs 5%; P = 0.72) and repeated percutaneous coronary intervention (19 vs 21%; P = 0.69) were similar in the ART group compared with the SV group. In the Cox regression analysis, type of revascularization was not an independent predictor of any long-term outcomes (death or major adverse cardiac events). In asymptomatic patients, exercise stress test at follow-up was comparable between the two groups (P = 0.14). Sequential vein CABG appears to have good early and long-term clinical outcomes. Also, early and long-term incidence of acute MI was not significantly higher in the SV group. However, further studies with a larger population are warranted in order to confirm the present results. © The Author 2014. Published by Oxford University Press on behalf of the European Association for

  8. Thermodynamic States of the Mixed Spin 1/2 and Spin 1 Hexagonal Nanowire System Obtained from a Seven-Site Cluster Within an Improved Mean Field Approximation

    NASA Astrophysics Data System (ADS)

    Mendes, R. G. B.; Barreto, F. C. Sá; Santos, J. P.

    2018-04-01

    The mean field approximation results in the mixedspin 1/2 Ising model and spin 1 Blume-Capel model, in the hexagonal nanowire system, are obtained from the Bogoliubov inequality. The Gibbs free energy, magnetization, and critical frontiers are obtained. Besides the stable branches of the order parameters, we obtain the metastable and unstable parts of these curves and also find phase transitions of the metastable branches of the order parameters. The classification of the stable, metastable, and unstable states is made by comparing the free energy values of these states.

  9. A rapid spin through oil results in higher cell-associated concentrations of antiretrovirals compared with conventional cell washing

    PubMed Central

    Cory, Theodore J; Winchester, Lee C; Robbins, Brian L; Fletcher, Courtney V

    2015-01-01

    Background: Determination of cell-associated antiretroviral drug concentrations is necessary for research into reservoirs of HIV. Variation exists in cell-associated drug concentrations among research groups. One cause for this may be washing cells during processing. We explored spinning cells through oil to minimize this variability. Methods & results: Raltegravir, atazanavir, darunavir, efavirenz, lopinavir and ritonavir concentrations were assessed in CEM.ss T cells washed with HBSS and oil-spun cells. Oil-spun cells had significantly higher concentrations for all drugs compared with samples washed with HBSS. Conclusion: The decline in cell-associated drug concentrations with saline washes compared with a single spin through oil shows the utility of a spin through oil. Oil centrifugation results in high cell-associated drug concentrations, and can be done in a fast, efficient manner. PMID:26168252

  10. Strategies for Obtaining Probability Samples of Homeless Youth

    ERIC Educational Resources Information Center

    Golinelli, Daniela; Tucker, Joan S.; Ryan, Gery W.; Wenzel, Suzanne L.

    2015-01-01

    Studies of homeless individuals typically sample subjects from few types of sites or regions within a metropolitan area. This article focuses on the biases that can result from such a practice. We obtained a probability sample of 419 homeless youth from 41 sites (shelters, drop-in centers, and streets) in four regions of Los Angeles County (LAC).…

  11. Comparison of the dose distribution obtained from dosimetric systems with intensity modulated radiotherapy planning system in the treatment of prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gökçe, M., E-mail: mgokce@adu.edu.tr; Uslu, D. Koçyiğit; Ertunç, C.

    The aim of this study is to compare Intensity Modulated Radiation Therapy (IMRT) plan of prostate cancer patients with different dose verification systems in dosimetric aspects and to compare these systems with each other in terms of reliability, applicability and application time. Dosimetric control processes of IMRT plan of three prostate cancer patients were carried out using thermoluminescent dosimeter (TLD), ion chamber (IC) and 2D Array detector systems. The difference between the dose values obtained from the dosimetric systems and treatment planning system (TPS) were found to be about % 5. For the measured (TLD) and calculated (TPS) doses %3more » percentage differences were obtained for the points close to center while percentage differences increased at the field edges. It was found that TLD and IC measurements will increase the precision and reliability of the results of 2D Array.« less

  12. Evaluation of several microcrystalline celluloses obtained from agricultural by-products

    PubMed Central

    Rojas, John; Lopez, Alvin; Guisao, Santiago; Ortiz, Carlos

    2011-01-01

    Microcrystalline cellulose (MCCI) has been widely used as an excipient for direct compression due to its good flowability, compressibility, and compactibility. In this study, MCCI was obtained from agricultural by-products, such as corn cob, sugar cane bagasse, rice husk, and cotton by pursuing acid hydrolysis, neutralization, clarification, and drying steps. Further, infrared spectroscopy (IR), X-ray diffraction (XRD), optical microscopy, degree of polymerization (DP), and powder and tableting properties were evaluated and compared to those of Avicel PH101, Avicel PH102, and Avicel PH200. Except for the commercial products, all materials showed a DP from 55 to 97. Particles of commercial products and corn cob had an irregular shape, whereas bagasse particles were elongated and thick. Rice and cotton particles exhibited a flake-like and fiber-like shape, respectively. MCCI as obtained from rice husk and cotton was the most densified material, while that produced from corn cob and bagasse was bulky, porous, and more compressible. All products had a moisture content of less than 10% and yields from 7.4% to 60.4%. MCCI as obtained from bagasse was the most porous and compressible material among all materials. This product also showed the best tableting properties along with Avicel products. Likewise, all MCCI products obtained from the above-mentioned sources showed a more rapid disintegration time than that of Avicel products. These materials can be used as a potential source of MCCI in the production of solid dosage forms. PMID:22171310

  13. Perceived concern about the new strain of the influenza and obtaining the vaccine in China, Japan and South Korea.

    PubMed

    Kamimura, Akiko; Armenta, Bianca A; Nourian, Maziar M; Wright, Lindsey; Rathi, Naveen; Chernenko, Alla

    This study compares the factors, which influence individuals from the countries of China, Japan and South Korea to obtain any type of influenza vaccines and their perceived concerns about the new strain of the influenza - pandemic (H1N1) 2009. The data analyzed was from the East Asian Social Survey (EASS), Cross-National Survey Data Sets: Health and Society in East Asia, 2010 (ICPSR 34608) (N=7938). The results of this study suggest that individuals who are concerned about the new strain of influenza are more likely to have obtained influenza vaccine. In these countries, perceived concerns may be directly related to vaccine-related behaviors. The results of this study also indicate that there are variations within each country regarding as to why individuals do or do not obtain the influenza vaccine. Over all, this project provides new insights about the acquisition of the influenza vaccine within China, Japan and South Korea, which will be useful for medical practice within these countries and future research. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  14. Soft Biometrics; Human Identification Using Comparative Descriptions.

    PubMed

    Reid, Daniel A; Nixon, Mark S; Stevenage, Sarah V

    2014-06-01

    Soft biometrics are a new form of biometric identification which use physical or behavioral traits that can be naturally described by humans. Unlike other biometric approaches, this allows identification based solely on verbal descriptions, bridging the semantic gap between biometrics and human description. To permit soft biometric identification the description must be accurate, yet conventional human descriptions comprising of absolute labels and estimations are often unreliable. A novel method of obtaining human descriptions will be introduced which utilizes comparative categorical labels to describe differences between subjects. This innovative approach has been shown to address many problems associated with absolute categorical labels-most critically, the descriptions contain more objective information and have increased discriminatory capabilities. Relative measurements of the subjects' traits can be inferred from comparative human descriptions using the Elo rating system. The resulting soft biometric signatures have been demonstrated to be robust and allow accurate recognition of subjects. Relative measurements can also be obtained from other forms of human representation. This is demonstrated using a support vector machine to determine relative measurements from gait biometric signatures-allowing retrieval of subjects from video footage by using human comparisons, bridging the semantic gap.

  15. Correlation of the Drag Characteristics of a Typical Pursuit Airplane Obtained from High-Speed Wind-Tunnel and Flight Tests

    NASA Technical Reports Server (NTRS)

    Nissen, James M; Gadebero, Burnett L; Hamilton, William T

    1948-01-01

    In order to obtain a correlation of drag data from wind-tunnel and flight tests at high Mach numbers, a typical pursuit airplane, with the propeller removed, was tested in flight at Mach numbers up to 0.755, and the results were compared with wind-tunnel tests of a 1/3-scale model of the airplane. The tests results show that the drag characteristics of the test airplane can be predicted with satisfactory accuracy from tests in the Ames 16-foot high-speed wind tunnel of the Ames Aeronautical Laboratory at both high and low Mach numbers. It is considered that this result is not unique with the airplane.

  16. Microbiologic Data in Acute Cholecystitis: Ten Years' Experience from Bile Cultures Obtained during Percutaneous Cholecystostomy.

    PubMed

    Nitzan, Orna; Brodsky, Yuri; Edelstein, Hana; Hershko, Dan; Saliba, Walid; Keness, Yoram; Peretz, Avi; Chazan, Bibiana

    2017-04-01

    The aim of the study was to describe the microbiology and susceptibility patterns in acute cholecystitis by examining bile culture results from patients who underwent percutaneous cholecystostomy and examine concordance with empiric treatment. A total of 124 patients with acute cholecystitis underwent percutaneous cholecystostomy between 2003 and 2012 at Emek Medical Center, Israel. Data on bile and blood culture results, isolate susceptibility, and clinical outcomes were retrieved from patient files. Bile cultures obtained from 116 patients were positive in 70 (60.3%) patients. Blood cultures obtained from 77 patients were positive in 23 (31.1%). Escherichia coli was the most common isolate in 28.6% of bile cultures and 43.5% of blood cultures. The concordance between empiric treatment coverage and culture isolate susceptibility was 67.6%. In most discordant cases, the isolates were Enterobacter spp. (40.9%) and Enterococcus spp. (31.8%). Overall, the in-hospital mortality rate was 7%: 2% in patients with concordant treatment compared with 14% in patients with discordant treatment (p = 0.09). Empiric antibiotic regimens were adequate in only two-thirds of patients. There might be a trend for poorer outcome in patients treated with inadequate antibiotic agents, emphasizing the importance of tailoring antibiotic treatment.

  17. Simulation of an active solar energy system integrated in a passive building in order to obtain system efficiency

    NASA Astrophysics Data System (ADS)

    Ceacaru, Mihai C.

    2012-11-01

    In this work we present a simulation of an active solar energy system. This system belongs to the first passive office building (2086 square meters) in Romania and it is used for water heating consumption. This office building was opened in February 2009 and was built based on passive house design solutions. For this simulation, we use Solar Water Heating module, which belongs to the software RETSCREEN and this simulation is done for several cities in Romania. Results obtained will be compared graphically.

  18. Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

    NASA Technical Reports Server (NTRS)

    Chipera, S. J.; Vaniman, D. T.; Bish, D. L.; Sarrazin, P.; Feldman, S.; Blake, D. F.; Bearman, G.; Bar-Cohen, Y.

    2004-01-01

    A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

  19. Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rondahl, Stina Holmgren; Pointurier, Fabien; Ahlinder, Linnea

    This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2, U 3O 8 and an intermediate species U 3Omore » 7 in the third material.« less

  20. Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise

    DOE PAGES

    Rondahl, Stina Holmgren; Pointurier, Fabien; Ahlinder, Linnea; ...

    2018-01-24

    This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2, U 3O 8 and an intermediate species U 3Omore » 7 in the third material.« less

  1. Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise.

    PubMed

    Rondahl, Stina Holmgren; Pointurier, Fabien; Ahlinder, Linnea; Ramebäck, Henrik; Marie, Olivier; Ravat, Brice; Delaunay, François; Young, Emma; Blagojevic, Ned; Hester, James R; Thorogood, Gordon; Nelwamondo, Aubrey N; Ntsoane, Tshepo P; Roberts, Sarah K; Holliday, Kiel S

    2018-01-01

    This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2 , U 3 O 8 and an intermediate species U 3 O 7 in the third material.

  2. Comparative Study of Green Sub- and Supercritical Processes to Obtain Carnosic Acid and Carnosol-Enriched Rosemary Extracts with in Vitro Anti-Proliferative Activity on Colon Cancer Cells

    PubMed Central

    Sánchez-Camargo, Andrea del Pilar; García-Cañas, Virginia; Herrero, Miguel; Cifuentes, Alejandro; Ibáñez, Elena

    2016-01-01

    In the present work, four green processes have been compared to evaluate their potential to obtain rosemary extracts with in vitro anti-proliferative activity against two colon cancer cell lines (HT-29 and HCT116). The processes, carried out under optimal conditions, were: (1) pressurized liquid extraction (PLE, using an hydroalcoholic mixture as solvent) at lab-scale; (2) Single-step supercritical fluid extraction (SFE) at pilot scale; (3) Intensified two-step sequential SFE at pilot scale; (4) Integrated PLE plus supercritical antisolvent fractionation (SAF) at pilot scale. Although higher extraction yields were achieved by using PLE (38.46% dry weight), this extract provided the lowest anti-proliferative activity with no observed cytotoxic effects at the assayed concentrations. On the other hand, extracts obtained using the PLE + SAF process provided the most active rosemary extracts against both colon cancer cell lines, with LC50 ranging from 11.2 to 12.4 µg/mL and from 21.8 to 31.9 µg/mL for HCT116 and HT-29, respectively. In general, active rosemary extracts were characterized by containing carnosic acid (CA) and carnosol (CS) at concentrations above 263.7 and 33.9 mg/g extract, respectively. Some distinct compounds have been identified in the SAF extracts (rosmaridiphenol and safficinolide), suggesting their possible role as additional contributors to the observed strong anti-proliferative activity of CA and CS in SAF extracts. PMID:27941607

  3. Finite element modelling of FRC beams containing PVA and Basalt fibres: A comparative study

    NASA Astrophysics Data System (ADS)

    Ayub, Tehmina; Khan, Sadaqat Ullah

    2017-09-01

    The endeavour of current study is to compare the flexural behaviour and three dimensional (3D) finite element analysis (FEA) and the results of FEM are compared with the experimental results of 07 HPFRC beams. Out of seven (07), 01 beam of plain concrete without fibres was cast as a control beam. Three (03) beams containing 1, 2 and 3% volume of PVA fibres were prepared by using HPFRC mixes while, the remaining other three (03) beams were prepared using HPFRC mixes containing 1, 2 and 3% volume of Basalt fibres. In order to ensure flexural failure, three-point bending load was applied at the mid span of all beams. The maximum flexural load and corresponding deflection and strains at the mid span attained prior to the failure were obtained as flexural test results. The FEM results were obtained by simulating all beams in ATENA 3D program and verified through flexural test results. Both of the results of FEM and Experiment showed good agreement with each other.

  4. Directional wave navigation radar measurements compared with pitch-roll buoy data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A.-Munoyerro, M.A.; Borge, J.C.N.

    1997-02-01

    The knowledge of the spectral behavior of a specific sea region is complete when one knows surface elevations and directional wave movements. Usually, sea directional descriptions have been made using pitch-roll buoys, which can provide one with several wave characteristic time series. Alternatively, there are other measure systems, which belong to remote sensing technics, such as shipboard navigation radars. The aim of the present work is to compare results obtained from pitch-roll data and ship radar wave measurements obtained during a campaign in the Cantabric Sea.

  5. [Comparative study of unidirectional transducers for invasive blood pressure monitoring].

    PubMed

    Matzek, F; Boenick, U; Frucht, U; Schroeder, P M

    1989-03-01

    This paper reports on the results of a study in which the offset drift, sensitivity error and drift, as well as the linearity error of six DPT's were investigated under normal ambient conditions and varying conditions of temperature, light, operating time and variation of supply voltage. In addition, the dynamic response, and the influence of storage at extreme temperatures, and resterilisation, was examined. The electrical and mechanical safety/reliability of DPT's was also investigated. The results obtained are compared.

  6. Comparing Cognitive Interviewing and Online Probing: Do They Find Similar Results?

    ERIC Educational Resources Information Center

    Meitinger, Katharina; Behr, Dorothée

    2016-01-01

    This study compares the application of probing techniques in cognitive interviewing (CI) and online probing (OP). Even though the probing is similar, the methods differ regarding typical mode setting, sample size, level of interactivity, and goals. We analyzed probing answers to the International Social Survey Programme item battery on specific…

  7. Lateral Load Capacity of Piles: A Comparative Study Between Indian Standards and Theoretical Approach

    NASA Astrophysics Data System (ADS)

    Jayasree, P. K.; Arun, K. V.; Oormila, R.; Sreelakshmi, H.

    2018-05-01

    As per Indian Standards, laterally loaded piles are usually analysed using the method adopted by IS 2911-2010 (Part 1/Section 2). But the practising engineers are of the opinion that the IS method is very conservative in design. This work aims at determining the extent to which the conventional IS design approach is conservative. This is done through a comparative study between IS approach and the theoretical model based on Vesic's equation. Bore log details for six different bridges were collected from the Kerala Public Works Department. Cast in situ fixed head piles embedded in three soil conditions both end bearing as well as friction piles were considered and analyzed separately. Piles were also modelled in STAAD.Pro software based on IS approach and the results were validated using Matlock and Reese (In Proceedings of fifth international conference on soil mechanics and foundation engineering, 1961) equation. The results were presented as the percentage variation in values of bending moment and deflection obtained by different methods. The results obtained from the mathematical model based on Vesic's equation and that obtained as per the IS approach were compared and the IS method was found to be uneconomical and conservative.

  8. Comparative Study on Different Slot Forms of Prestressed Anchor Blocks

    NASA Astrophysics Data System (ADS)

    Fan, Rong; Si, Jianhui; Jian, Zheng

    2018-03-01

    In this paper, two models of prestressed pier, rectangular cavity anchor block and arch hollow anchor block are established. The ABAQUS software was used to calculate the stress of the surface of the neck of the pier and the cavity of the anchor block, through comparative analysis. The results show that compared with the rectangular cavity anchor block, the stress of the pier and the cavity can be effectively reduced when the arch hole is used, and the amount of prestressed anchor can be reduced, so as to obtain obvious economic benefits.

  9. results obtained by the application of two different methods for the calculation of optimal coplanar orbital maneuvers with time limit

    NASA Astrophysics Data System (ADS)

    Rocco, Emr; Prado, Afbap; Souza, Mlos

    In this work, the problem of bi-impulsive orbital transfers between coplanar elliptical orbits with minimum fuel consumption but with a time limit for this transfer is studied. As a first method, the equations presented by Lawden (1993) were used. Those equations furnishes the optimal transfer orbit with fixed time for this transfer, between two elliptical coplanar orbits considering fixed terminal points. The method was adapted to cases with free terminal points and those equations was solved to develop a software for orbital maneuvers. As a second method, the equations presented by Eckel and Vinh (1984) were used, those equations provide the transfer orbit between non-coplanar elliptical orbits with minimum fuel and fixed time transfer, or minimum time transfer for a prescribed fuel consumption, considering free terminal points. But in this work only the problem with fixed time transfer was considered, the case of minimum time for a prescribed fuel consumption was already studied in Rocco et al. (2000). Then, the method was modified to consider cases of coplanar orbital transfer, and develop a software for orbital maneuvers. Therefore, two software that solve the same problem using different methods were developed. The first method, presented by Lawden, uses the primer vector theory. The second method, presented by Eckel and Vinh, uses the ordinary theory of maxima and minima. So, to test the methods we choose the same terminal orbits and the same time as input. We could verify that we didn't obtain exactly the same result. In this work, that is an extension of Rocco et al. (2002), these differences in the results are explored with objective of determining the reason of the occurrence of these differences and which modifications should be done to eliminate them.

  10. Hydrodesulfurization and hydrodenitrogenation catalysts obtained from coal mineral matter

    DOEpatents

    Liu, Kindtoken H. D.; Hamrin, Jr., Charles E.

    1982-01-01

    A hydrotreating catalyst is prepared from coal mineral matter obtained by low temperature ashing coals of relatively low bassanite content by the steps of: (a) depositing on the low temperature ash 0.25-3 grams of an iron or nickel salt in water per gram of ash and drying a resulting slurry; (b) crushing and sizing a resulting solid; and (c) heating the thus-sized solid powder in hydrogen.

  11. Effect of 25(OH) vitamin D reference method procedure (RMP) alignment on clinical measurements obtained with the IDS-iSYS chemiluminescent-based automated analyzer.

    PubMed

    Simpson, Christine A; Cusano, Anna Maria; Bihuniak, Jessica; Walker, Joanne; Insogna, Karl L

    2015-04-01

    The Vitamin D Standardization Program (VDSP) has identified ID-LC/MS/MS as the reference method procedure (RMP) for 25(OH) vitamin D and NIST Standard SRM2972 as the standard reference material (SRM). As manufacturers align their products to the RMP and NIST standard, a concern is that results obtained in aligned assays will be divergent from those obtained with pre-alignment assays. The Immunodiagnostic Systems Ltd., chemiluminescent, 25(OH) vitamin D iSYS platform assay, was recently harmonized to the RMP. To determine the impact of standardization on results obtained with iSYS reagents, 119 single donor serum samples from eight different disease categories were analyzed in four non-standardized and two standardized iSYS assays. There were strong correlations between the four non-standardized and two standardized assays with Spearman's rank r values between 0.975 and 0.961 and four of the eight r values were >0.97. R(2) values for the eight best-fit linear regression equations ranging between 0.947 and 0.916. None of the slopes were found to be significantly different from one another. Bland-Altman plots showed that the bias was comparable when each of the four non-standardized assays was compared to either of the standardized assays. When the data were segregated in values between 6 and 49ng/mL (15-122nmol/L) or between 50 and 100ng/mL (125-250nmol/L) significant associations remained between results obtained with non-standardized and standardized calibrators regardless of the absolute value. When five recent DEQAS unknowns were analyzed in one non-standardized and one standardized assay the mean percent difference from the NIST target in values obtained using standardized vs. non-standardized calibrators were not significantly different. Finally, strong and statistically significant associations between the results were obtained using non-standardized and standardized assays for six of eight clinical conditions. The only exceptions were hypocalcemia and breast

  12. Comparative study of open and arthroscopic coracoid transfer for shoulder anterior instability (Latarjet)-clinical results at short term follow-up.

    PubMed

    Kordasiewicz, Bartłomiej; Małachowski, Konrad; Kicinski, Maciej; Chaberek, Sławomir; Pomianowski, Stanisław

    2017-05-01

    The aim of this study was to compare early clinical results after open and arthroscopic Latarjet stabilisation in anterior shoulder instability. Our hypothesis was the results of arthroscopic stabilisation were comparable with the results of open procedure. The clinical results of the patients after primary Latarjet procedure were analysed. Patients operated on between 2006 and 2011 using an open technique composed the OPEN group and patients operated on arthroscopically between 2011 and 2013 composed the ARTHRO group; 48 out of 55 shoulders (87%) in OPEN and 62 out of 64 shoulders (97%) in ARTHRO were available to follow-up. The average age at surgery was 28 years in OPEN and 26 years in ARTHRO. The mean follow-up was 54.2 months in OPEN and 23.4 months in ARTHRO. Intra-operative data were analysed regarding time of surgery, concomitant lesions and complications. Patient results were assessed with Walch-Duplay, Rowe, VAS scores and subjective self-evaluation of satisfaction and shoulder function. Computed tomography scan evaluation was used to assess the graft healing. Average time of surgery was significantly shorter in ARTHRO than OPEN: respectively 110 and 120 minutes. The number of intra-operative complications was six (12.5%) in OPEN and five (8.1%) in ARTHRO. The results were comparable in both groups, with no significant difference between OPEN and ARTHRO group: satisfaction rate - 96.8% and 91.9%, shoulder function - 92.2% and 90%, Walch-Duplay score - 83.9 and 76.7 respecively. A significant difference was reported in Rowe score: 87.8 in OPEN and 78.9 in ARTHRO. Another significant difference was found in the presence of "subjective apprehension"-a term referring to the subjective perception of instability with no signs of instability at clinical examination - 28.7% in OPEN and 50% in ARTHRO. Range of motion in both groups were comparable, however patients in OPEN had significantly lower loss of external rotation in adduction to the side comparing to the

  13. Leachates from solid wastes: chemical and eco(geno)toxicological differences between leachates obtained from fresh and stabilized industrial organic sludge.

    PubMed

    Chiochetta, Claudete G; Goetten, Luís C; Almeida, Sônia M; Quaranta, Gaetana; Cotelle, Sylvie; Radetski, Claudemir M

    2014-01-01

    The chemical and ecotoxicological characteristics of fresh and stabilized industrial organic sludge leachates were compared to obtain information regarding how the stabilization process can influence the ecotoxic potential of this industrial waste, which could be used for the amendment of degraded soil. Physicochemical analysis of the sludge leachates, as well as a battery of eco(geno)toxicity tests on bacteria, algae, daphnids, and higher plants (including Vicia faba genotoxicity test) and the determination of hydrolytic enzyme activity, was performed according to standard methods. The chemical comparison of the two types of leachate showed that the samples obtained from stabilized sludge had a lower organic content and higher metal content than leachates of the fresh sludge. The eco(geno)toxicological results obtained with aquatic organisms showed that the stabilized sludge leachate was more toxic than the fresh sludge leachate, both originating from the same industrial organic sludge sample. Nevertheless, phytotoxicity tests carried out with a reference peat soil irrigated with stabilized sludge leachate showed the same toxicity as the fresh sludge leachate. In the case of the industrial solid organic sludge studied, stabilization through a biodegradation process promoted a higher metal mobility/bioavailability/eco(geno)toxicity in the stabilized sludge leachate compared to the fresh sludge leachate.

  14. Results of the 1974 NACUBO Comparative Performance Study and Investment Questionnaire.

    ERIC Educational Resources Information Center

    National Association of College and University Business Officers, Washington, DC.

    The 1974 Comparative Performance Study includes 150 endowment pools representing 136 institutions. The market value of the pools which provided information as of June 30, 1974, was 6.9 billion dollars. The study identifies endowment pools by code and indicates each pool's investment objective, approximate market value, the percentage in cash and…

  15. Histology of periapical lesions obtained during apical surgery.

    PubMed

    Schulz, Malte; von Arx, Thomas; Altermatt, Hans Jörg; Bosshardt, Dieter

    2009-05-01

    The aim of this was to evaluate the histology of periapical lesions in teeth treated with periapical surgery. After root-end resection, the root tip was removed together with the periapical pathological tissue. Histologic sectioning was performed on calcified specimens embedded in methylmethacrylate (MMA) and on demineralized specimens embedded in LR White (Fluka, Buchs, Switzerland). The samples were evaluated with light and transmission electron microscopy (TEM). The histologic findings were classified into periapical abscesses, granulomas, or cystic lesions (true or pocket cysts). The final material comprised 70% granulomas, 23% cysts and 5% abscesses, 1% scar tissues, and 1% keratocysts. Six of 125 samples could not be used. The cystic lesions could not be subdivided into pocket or true cysts. All cysts had an epithelium-lined cavity, two of them with cilia-lined epithelium. These results show the high incidence of periapical granulomas among periapical lesions obtained during apical surgery. Periapical abscesses were a rare occasion. The histologic findings from samples obtained during apical surgery may differ from findings obtained by teeth extractions. A determination between pocket and true apical cysts is hardly possible when collecting samples by apical surgery.

  16. Decline in placebo-controlled trial results suggests new directions for comparative effectiveness research.

    PubMed

    Olfson, Mark; Marcus, Steven C

    2013-06-01

    The Affordable Care Act offers strong support for comparative effectiveness research, which entails comparisons among active treatments, to provide the foundation for evidence-based practice. Traditionally, a key form of research into the effectiveness of therapeutic treatments has been placebo-controlled trials, in which a specified treatment is compared to placebo. These trials feature high-contrast comparisons between treatments. Historical trends in placebo-controlled trials have been evaluated to help guide the comparative effectiveness research agenda. We investigated placebo-controlled trials reported in four leading medical journals between 1966 and 2010. We found that there was a significant decline in average effect size or average difference in efficacy (the ability to produce a desired effect) between the active treatment and placebo. On average, recently studied treatments offered only small benefits in efficacy over placebo. A decline in effect sizes in conventional placebo-controlled trials supports an increased emphasis on other avenues of research, including comparative studies on the safety, tolerability, and cost of treatments with established efficacy.

  17. A Comparison of Medication Histories Obtained by a Pharmacy Technician Versus Nurses in the Emergency Department

    PubMed Central

    Markovic, Marija; Mathis, A. Scott; Ghin, Hoytin Lee; Gardiner, Michelle; Fahim, Germin

    2017-01-01

    Purpose: To compare the medication history error rate of the emergency department (ED) pharmacy technician with that of nursing staff and to describe the workflow environment. Methods: Fifty medication histories performed by an ED nurse followed by the pharmacy technician were evaluated for discrepancies (RN-PT group). A separate 50 medication histories performed by the pharmacy technician and observed with necessary intervention by the ED pharmacist were evaluated for discrepancies (PT-RPh group). Discrepancies were totaled and categorized by type of error and therapeutic category of the medication. The workflow description was obtained by observation and staff interview. Results: A total of 474 medications in the RN-PT group and 521 in the PT-RPh group were evaluated. Nurses made at least one error in all 50 medication histories (100%), compared to 18 medication histories for the pharmacy technician (36%). In the RN-PT group, 408 medications had at least one error, corresponding to an accuracy rate of 14% for nurses. In the PT-RPh group, 30 medications had an error, corresponding to an accuracy rate of 94.4% for the pharmacy technician (P < 0.0001). The most common error made by nurses was a missing medication (n = 109), while the most common error for the pharmacy technician was a wrong medication frequency (n = 19). The most common drug class with documented errors for ED nurses was cardiovascular medications (n = 100), while the pharmacy technician made the most errors in gastrointestinal medications (n = 11). Conclusion: Medication histories obtained by the pharmacy technician were significantly more accurate than those obtained by nurses in the emergency department. PMID:28090164

  18. First results from stellar occultations in the "GAIA era"

    NASA Astrophysics Data System (ADS)

    Benedetti-Rossi, G.; Vieira-Martins, R.; Sicardy, B.

    2017-09-01

    Stellar occultation is a powerful technique to study distant solar system bodies. It allows high angular resolution of the occulting body from the analysis of a light curve acquired with high temporal resolution with uncertainties comparable as probes. In the "GAIA era", stellar occultations is now able to obtain even more impressive results such as the presence of atmosphere, rings and topographic features.

  19. Comparing the Similarity of Responses Received from Studies in Amazon’s Mechanical Turk to Studies Conducted Online and with Direct Recruitment

    PubMed Central

    Bartneck, Christoph; Duenser, Andreas; Moltchanova, Elena; Zawieska, Karolina

    2015-01-01

    Computer and internet based questionnaires have become a standard tool in Human-Computer Interaction research and other related fields, such as psychology and sociology. Amazon’s Mechanical Turk (AMT) service is a new method of recruiting participants and conducting certain types of experiments. This study compares whether participants recruited through AMT give different responses than participants recruited through an online forum or recruited directly on a university campus. Moreover, we compare whether a study conducted within AMT results in different responses compared to a study for which participants are recruited through AMT but which is conducted using an external online questionnaire service. The results of this study show that there is a statistical difference between results obtained from participants recruited through AMT compared to the results from the participant recruited on campus or through online forums. We do, however, argue that this difference is so small that it has no practical consequence. There was no significant difference between running the study within AMT compared to running it with an online questionnaire service. There was no significant difference between results obtained directly from within AMT compared to results obtained in the campus and online forum condition. This may suggest that AMT is a viable and economical option for recruiting participants and for conducting studies as setting up and running a study with AMT generally requires less effort and time compared to other frequently used methods. We discuss our findings as well as limitations of using AMT for empirical studies. PMID:25876027

  20. Quantitative Radiology: Automated CT Liver Volumetry Compared With Interactive Volumetry and Manual Volumetry

    PubMed Central

    Suzuki, Kenji; Epstein, Mark L.; Kohlbrenner, Ryan; Garg, Shailesh; Hori, Masatoshi; Oto, Aytekin; Baron, Richard L.

    2014-01-01

    OBJECTIVE The purpose of this study was to evaluate automated CT volumetry in the assessment of living-donor livers for transplant and to compare this technique with software-aided interactive volumetry and manual volumetry. MATERIALS AND METHODS Hepatic CT scans of 18 consecutively registered prospective liver donors were obtained under a liver transplant protocol. Automated liver volumetry was developed on the basis of 3D active-contour segmentation. To establish reference standard liver volumes, a radiologist manually traced the contour of the liver on each CT slice. We compared the results obtained with automated and interactive volumetry with those obtained with the reference standard for this study, manual volumetry. RESULTS The average interactive liver volume was 1553 ± 343 cm3, and the average automated liver volume was 1520 ± 378 cm3. The average manual volume was 1486 ± 343 cm3. Both interactive and automated volumetric results had excellent agreement with manual volumetric results (intraclass correlation coefficients, 0.96 and 0.94). The average user time for automated volumetry was 0.57 ± 0.06 min/case, whereas those for interactive and manual volumetry were 27.3 ± 4.6 and 39.4 ± 5.5 min/case, the difference being statistically significant (p < 0.05). CONCLUSION Both interactive and automated volumetry are accurate for measuring liver volume with CT, but automated volumetry is substantially more efficient. PMID:21940543

  1. Dimeric spectra analysis in Microsoft Excel: a comparative study.

    PubMed

    Gilani, A Ghanadzadeh; Moghadam, M; Zakerhamidi, M S

    2011-11-01

    The purpose of this work is to introduce the reader to an Add-in implementation, Decom. This implementation provides the whole processing requirements for analysis of dimeric spectra. General linear and nonlinear decomposition algorithms were integrated as an Excel Add-in for easy installation and usage. In this work, the results of several samples investigations were compared to those obtained by Datan. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. The application of parameter estimation to flight measurements to obtain lateral-directional stability derivatives of an augmented jet-flap STOL airplane

    NASA Technical Reports Server (NTRS)

    Stephenson, J. D.

    1983-01-01

    Flight experiments with an augmented jet flap STOL aircraft provided data from which the lateral directional stability and control derivatives were calculated by applying a linear regression parameter estimation procedure. The tests, which were conducted with the jet flaps set at a 65 deg deflection, covered a large range of angles of attack and engine power settings. The effect of changing the angle of the jet thrust vector was also investigated. Test results are compared with stability derivatives that had been predicted. The roll damping derived from the tests was significantly larger than had been predicted, whereas the other derivatives were generally in agreement with the predictions. Results obtained using a maximum likelihood estimation procedure are compared with those from the linear regression solutions.

  3. A comparison of defect size and film quality obtained from Film digitized image and digital image radiographs

    NASA Astrophysics Data System (ADS)

    Kamlangkeng, Poramate; Asa, Prateepasen; Mai, Noipitak

    2014-06-01

    Digital radiographic testing is an acceptable premature nondestructive examination technique. Its performance and limitation comparing to the old technique are still not widely well known. In this paper conducted the study on the comparison of the accuracy of the defect size measurement and film quality obtained from film and digital radiograph techniques by testing in specimens and known size sample defect. Initially, one specimen was built with three types of internal defect; which are longitudinal cracking, lack of fusion, and porosity. For the known size sample defect, it was machined various geometrical size for comparing the accuracy of the measuring defect size to the real size in both film and digital images. To compare the image quality by considering at smallest detectable wire and the three defect images. In this research used Image Quality Indicator (IQI) of wire type 10/16 FE EN BS EN-462-1-1994. The radiographic films were produced by X-ray and gamma ray using Kodak AA400 size 3.5x8 inches, while the digital images were produced by Fuji image plate type ST-VI with 100 micrometers resolution. During the tests, a radiator GE model MF3 was implemented. The applied energy is varied from 120 to 220 kV and the current from 1.2 to 3.0 mA. The intensity of Iridium 192 gamma ray is in the range of 24-25 Curie. Under the mentioned conditions, the results showed that the deviation of the defect size measurement comparing to the real size obtained from the digital image radiographs is below than that of the film digitized, whereas the quality of film digitizer radiographs is higher in comparison.

  4. Obtaining coincident image observations for Mission to Planet Earth science data return

    NASA Technical Reports Server (NTRS)

    Newman, Lauri Kraft; Folta, David C.; Farrell, James P.

    1994-01-01

    One objective of the Mission to Planet Earth (MTPE) program involves comparing data from various instruments on multiple spacecraft to obtain a total picture of the Earth's systems. To correlate image data from instruments on different spacecraft, these spacecraft must be able to image the same location on the Earth at approximately the same time. Depending on the orbits of the spacecraft involved, complicated operational details must be considered to obtain such observations. If the spacecraft are in similar orbits, close formation flying or synchronization techniques may be used to assure coincident observations. If the orbits are dissimilar, the launch time of the second satellite may need to be restricted in order to align its orbit with that of the first satellite launched. This paper examines strategies for obtaining coincident observations for spacecraft in both similar and dissimilar orbits. Although these calculations may be performed easily for coplanar spacecraft, the non-coplanar case involves additional considerations which are incorporated into the algorithms presented herein.

  5. A quantum algorithm for obtaining the lowest eigenstate of a Hamiltonian assisted with an ancillary qubit system

    NASA Astrophysics Data System (ADS)

    Bang, Jeongho; Lee, Seung-Woo; Lee, Chang-Woo; Jeong, Hyunseok

    2015-01-01

    We propose a quantum algorithm to obtain the lowest eigenstate of any Hamiltonian simulated by a quantum computer. The proposed algorithm begins with an arbitrary initial state of the simulated system. A finite series of transforms is iteratively applied to the initial state assisted with an ancillary qubit. The fraction of the lowest eigenstate in the initial state is then amplified up to 1. We prove that our algorithm can faithfully work for any arbitrary Hamiltonian in the theoretical analysis. Numerical analyses are also carried out. We firstly provide a numerical proof-of-principle demonstration with a simple Hamiltonian in order to compare our scheme with the so-called "Demon-like algorithmic cooling (DLAC)", recently proposed in Xu (Nat Photonics 8:113, 2014). The result shows a good agreement with our theoretical analysis, exhibiting the comparable behavior to the best `cooling' with the DLAC method. We then consider a random Hamiltonian model for further analysis of our algorithm. By numerical simulations, we show that the total number of iterations is proportional to , where is the difference between the two lowest eigenvalues and is an error defined as the probability that the finally obtained system state is in an unexpected (i.e., not the lowest) eigenstate.

  6. Exploratory study on a statistical method to analyse time resolved data obtained during nanomaterial exposure measurements

    NASA Astrophysics Data System (ADS)

    Clerc, F.; Njiki-Menga, G.-H.; Witschger, O.

    2013-04-01

    Most of the measurement strategies that are suggested at the international level to assess workplace exposure to nanomaterials rely on devices measuring, in real time, airborne particles concentrations (according different metrics). Since none of the instruments to measure aerosols can distinguish a particle of interest to the background aerosol, the statistical analysis of time resolved data requires special attention. So far, very few approaches have been used for statistical analysis in the literature. This ranges from simple qualitative analysis of graphs to the implementation of more complex statistical models. To date, there is still no consensus on a particular approach and the current period is always looking for an appropriate and robust method. In this context, this exploratory study investigates a statistical method to analyse time resolved data based on a Bayesian probabilistic approach. To investigate and illustrate the use of the this statistical method, particle number concentration data from a workplace study that investigated the potential for exposure via inhalation from cleanout operations by sandpapering of a reactor producing nanocomposite thin films have been used. In this workplace study, the background issue has been addressed through the near-field and far-field approaches and several size integrated and time resolved devices have been used. The analysis of the results presented here focuses only on data obtained with two handheld condensation particle counters. While one was measuring at the source of the released particles, the other one was measuring in parallel far-field. The Bayesian probabilistic approach allows a probabilistic modelling of data series, and the observed task is modelled in the form of probability distributions. The probability distributions issuing from time resolved data obtained at the source can be compared with the probability distributions issuing from the time resolved data obtained far-field, leading in a

  7. Research of obtaining TiO2 by sol-gel method using titanium isopropoxide TIP and tetra-n-butyl orthotitanate TNB

    NASA Astrophysics Data System (ADS)

    Gómez de Salazar, J. M.; Nutescu Duduman, C.; Juárez Gonzalez, M.; Palamarciuc, I.; Barrena Pérez, M. I.; Carcea, I.

    2016-08-01

    Titanium dioxide crystallises in three polymorphs: anatase, rutile and brookite. Rutile is most stable form of the TiO2 polymorphs. In this paper we concentrate on obtaining rutile and anatase, both used in various applications. The chosen method is sol-gel, which is a reliable method used for obtaining titanium oxides. We prepared titanium dioxide with using titanium isopropoxide (TIP) with chemical construction (C12H28O4Ti) and tetra-n-butyl orthotitanate (TNB) with chemical construction (C16H36O4Ti). The experiments were carried out in order to compare the results of the samples with similar reaction conditions, but with different precursors, thus concluding which precursor gives best results. Using different analysis techniques as X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and Thermogravimetric Analysis (TGA) we characterised the samples morphologically and structurally.

  8. Deploying and sharing U-Compare workflows as web services

    PubMed Central

    2013-01-01

    Background U-Compare is a text mining platform that allows the construction, evaluation and comparison of text mining workflows. U-Compare contains a large library of components that are tuned to the biomedical domain. Users can rapidly develop biomedical text mining workflows by mixing and matching U-Compare’s components. Workflows developed using U-Compare can be exported and sent to other users who, in turn, can import and re-use them. However, the resulting workflows are standalone applications, i.e., software tools that run and are accessible only via a local machine, and that can only be run with the U-Compare platform. Results We address the above issues by extending U-Compare to convert standalone workflows into web services automatically, via a two-click process. The resulting web services can be registered on a central server and made publicly available. Alternatively, users can make web services available on their own servers, after installing the web application framework, which is part of the extension to U-Compare. We have performed a user-oriented evaluation of the proposed extension, by asking users who have tested the enhanced functionality of U-Compare to complete questionnaires that assess its functionality, reliability, usability, efficiency and maintainability. The results obtained reveal that the new functionality is well received by users. Conclusions The web services produced by U-Compare are built on top of open standards, i.e., REST and SOAP protocols, and therefore, they are decoupled from the underlying platform. Exported workflows can be integrated with any application that supports these open standards. We demonstrate how the newly extended U-Compare enhances the cross-platform interoperability of workflows, by seamlessly importing a number of text mining workflow web services exported from U-Compare into Taverna, i.e., a generic scientific workflow construction platform. PMID:23419017

  9. Evaluation of agreement between temporal series obtained from electrocardiogram and pulse wave.

    NASA Astrophysics Data System (ADS)

    Leikan, GM; Rossi, E.; Sanz, MCuadra; Delisle Rodríguez, D.; Mántaras, MC; Nicolet, J.; Zapata, D.; Lapyckyj, I.; Siri, L. Nicola; Perrone, MS

    2016-04-01

    Heart rate variability allows to study the cardiovascular autonomic nervous system modulation. Usually, this signal is obtained from the electrocardiogram (ECG). A simpler method for recording the pulse wave (PW) is by means of finger photoplethysmography (PPG), which also provides information about the duration of the cardiac cycle. In this study, the correlation and agreement between the time series of the intervals between heartbeats obtained from the ECG with those obtained from the PPG, were studied. Signals analyzed were obtained from young, healthy and resting subjects. For statistical analysis, the Pearson correlation coefficient and the Bland and Altman limits of agreement were used. Results show that the time series constructed from the PW would not replace the ones obtained from ECG.

  10. Comparative Study of Several Energy Dissipating Devices

    NASA Astrophysics Data System (ADS)

    Abdul-Latif, A.

    2011-11-01

    Large plastic lateral collapse problem of two geometrically identical hollow cylinders under compressive load is of particular interest in this work, since, the energy absorbed can be characterized by a smooth loaded deflection relation, and these tubes are also easier to build than most other devices. Cylinders of various geometrical parameters (i.e., inside/outside diameter ratios: R = di/do ranging from 0 to 0.473) are used having the same cross-sectional area and length. Superplastic material used in this study has a considerably sensitivity to the quasi-static strain rate in the range of (10-5 to 10-3/s). Hence, this material could be employed as a representative material to simulate the classical engineering material behavior under high strain rate. Comparative study of different structural situations is conducted using four energy dissipating devices designed and investigated by the author in previous works. They are: (1) two geometrically identical cylinders made of superplastic tin-lead alloy can freely expand along their sides and lengths; (2) two cylinders are the same as in (1) but not allowed to expand along their sides and lengths; (3) one cylinder is made from superplastic and the other made from steel and free to deform along its sides and length; (4) the same as in (3) but the cylinder is not allowed to expand along its sides and length. Based on the obtained experimental results, the features of each device in dissipating the energy during the large plastic collapse are investigated. It is concluded that the energy absorbed for a given system decreases with the increase of the R ratio. It is recognized that the highest absorbed energy is obtained in the constrained situation with deformable non-deformable compared to the other situations. Moreover, through the finite element simulations, the flow mechanism in each device is studied and compared to the experimental results.

  11. Case Studies Comparing System Advisor Model (SAM) Results to Real Performance Data: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blair, N.; Dobos, A.; Sather, N.

    2012-06-01

    NREL has completed a series of detailed case studies comparing the simulations of the System Advisor Model (SAM) and measured performance data or published performance expectations. These case studies compare PV measured performance data with simulated performance data using appropriate weather data. The measured data sets were primarily taken from NREL onsite PV systems and weather monitoring stations.

  12. Description of a Pressure Measurement Technique for Obtaining Surface Static Pressures of a Radial Turbine

    NASA Technical Reports Server (NTRS)

    Dicicco, L. Danielle; Nowlin, Brent C.; Tirres, Lizet

    1992-01-01

    The aerodynamic performance of a solid uncooled version of a cooled radial turbine was evaluated in the Small Engine Components Test Facility Turbine rig at the NASA Lewis Research Center. Specifically, an experiment was conducted to rotor surface static pressures. This was the first time surface static pressures had been measured on a radial turbine at NASA Lewis. These pressures were measured by a modified Rotating Data Package (RDP), a standard product manufactured by Scanivalve, Inc. Described here are the RDP, and the modifications that were made, as well as the checkout, installation, and testing procedures. The data presented are compared to analytical results obtained from NASA's MERIDL TSONIC BLAYER (MTSB) code.

  13. Description of a pressure measurement technique for obtaining surface static pressures of a radial turbine

    NASA Technical Reports Server (NTRS)

    Dicicco, L. D.; Nowlin, Brent C.; Tirres, Lizet

    1992-01-01

    The aerodynamic performance of a solid uncooled version of a cooled radial turbine was evaluated in the Small Engine Components Test Facility Turbine rig at the NASA Lewis Research Center. Specifically, an experiment was conducted to rotor surface static pressures. This was the first time surface static pressures had been measured on a radial turbine at NASA Lewis. These pressures were measured by a modified Rotating Data Package (RDP), a standard product manufactured by Scanivalve, Inc. Described here are the RDP, and the modifications that were made, as well as the checkout, installation, and testing procedures. The data presented are compared to analytical results obtained from NASA's MERIDL TSONIC BLAYER (MTSB) code.

  14. Photoluminescence of silicon nanowires obtained by epitaxial chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Demichel, O.; Oehler, F.; Calvo, V.; Noé, P.; Pauc, N.; Gentile, P.; Ferret, P.; Baron, T.; Magnea, N.

    2009-05-01

    We have carried out photoluminescence measurements of silicon nanowires (SiNWs) obtained by the chemical vapor deposition method with a copper-catalyzed vapor-liquid-solid mechanism. The nanowires have a typical diameter of 200 nm. Spectrum of the as-grown SiNWs exhibits radiative states below the energy bandgap and a small contribution near the silicon gap energy at 1.08 eV. A thermal oxidation allows to decrease the intensity at low energy and to enhance the intensity of the 1.08 eV contribution. The behavior of this contribution as a function of the pump power is correlated to a free carrier recombination. Furthermore, the spatial confinement of the carriers in SiNWs could explain the difference of shape and recombination energy of this contribution compared to the recombination of free exciton in the bulk silicon. The electronic system seems to be in an electron-hole plasma (ehp), as it has already been shown in SOI structures [M. Tajima, et al., J. Appl. Phys. 84 (1998) 2224]. A simulation of the radiative emission of an ehp is performed and results are discussed.

  15. Statistical correlation analysis for comparing vibration data from test and analysis

    NASA Technical Reports Server (NTRS)

    Butler, T. G.; Strang, R. F.; Purves, L. R.; Hershfeld, D. J.

    1986-01-01

    A theory was developed to compare vibration modes obtained by NASTRAN analysis with those obtained experimentally. Because many more analytical modes can be obtained than experimental modes, the analytical set was treated as expansion functions for putting both sources in comparative form. The dimensional symmetry was developed for three general cases: nonsymmetric whole model compared with a nonsymmetric whole structural test, symmetric analytical portion compared with a symmetric experimental portion, and analytical symmetric portion with a whole experimental test. The theory was coded and a statistical correlation program was installed as a utility. The theory is established with small classical structures.

  16. Achieving equal pay for comparable worth through arbitration.

    PubMed

    Wisniewski, S C

    1982-01-01

    Traditional "women's jobs" often pay relatively low wages because of the effects of institutionalized stereotypes concerning women and their role in the work place. One way of dealing with sex discrimination that results in job segregation is to narrow the existing wage differential between "men's jobs" and "women's jobs." Where the jobs are dissimilar on their face, this narrowing of pay differences involves implementing the concept of "equal pay for jobs of comparable worth." Some time in the future, far-reaching, perhaps even industrywide, reductions in male-female pay differentials may be achieved by pursuing legal remedies based on equal pay for comparable worth. However, as the author demonstrates, immediate, albeit more limited, relief for sex-based pay inequities found in specific work places can be obtained by implementing equal pay for jobs of comparable worth through the collective bargaining and arbitration processes.

  17. Magnetic biocatalysts and their uses to obtain bioproducts

    NASA Astrophysics Data System (ADS)

    López, Carmen; Cruz-Izquierdo, Álvaro; Picó, Enrique; García-Bárcena, Teresa; Villarroel, Noelia; Llama, María; Serra, Juan

    2014-08-01

    Nanobiocatalysis, as the synergistic combination of nanotechnology and biocatalysis, is rapidly emerging as a new frontier of biotechnology. The use of immobilized enzymes in industrial applications often presents advantages over their soluble counterparts, mainly in view of stability, reusability and simpler operational processing. Because of their singular properties, such as biocompatibility, large and modifiable surface and easy recovery, iron oxide magnetic nanoparticles (MNPs) are attractive super-paramagnetic materials that serve as a support for enzyme immobilization and facilitate separations by applying an external magnetic field. Cross-linked enzyme aggregates (CLEAs) have several benefits in the context of industrial applications since they can be cheaply and easily prepared from unpurified enzyme extracts and show improved storage and operational stability against denaturation by heat and organic solvents. In this work, by using the aforementioned advantages of MNPs of magnetite and CLEAs, we prepared two robust magnetically-separable types of nanobiocatalysts by binding either soluble enzyme onto the surface of MNPs functionalized with amino groups or by cross-linking aggregates of enzyme among them and to MNPs to obtain magnetic CLEAs. For this purpose the lipase B of Candida antarctica (CALB) was used. The hydrolytic and biosynthetic activities of the resulting magnetic nanobiocatalysts were assessed in aqueous and organic media and compared between them and to those showed by the corresponding soluble enzyme. Thus, the hydrolysis of triglycerides or the transesterification reactions to synthesize biodiesel and biosurfactants were studied using magnetic CLEAs of CALB.

  18. Comparing and Contrasting Consensus versus Empirical Domains

    PubMed Central

    Jason, Leonard A.; Kot, Bobby; Sunnquist, Madison; Brown, Abigail; Reed, Jordan; Furst, Jacob; Newton, Julia L.; Strand, Elin Bolle; Vernon, Suzanne D.

    2015-01-01

    Background Since the publication of the CFS case definition [1], there have been a number of other criteria proposed including the Canadian Consensus Criteria [2] and the Myalgic Encephalomyelitis: International Consensus Criteria. [3] Purpose The current study compared these domains that were developed through consensus methods to one obtained through more empirical approaches using factor analysis. Methods Using data mining, we compared and contrasted fundamental features of consensus-based criteria versus empirical latent factors. In general, these approaches found the domain of Fatigue/Post-exertional malaise as best differentiating patients from controls. Results Findings indicated that the Fukuda et al. criteria had the worst sensitivity and specificity. Conclusions These outcomes might help both theorists and researchers better determine which fundamental domains to be used for the case definition. PMID:26977374

  19. [The importance of memory bias in obtaining age of menarche by recall method in Brazilian adolescents].

    PubMed

    Castilho, Silvia Diez; Nucci, Luciana Bertoldi; Assuino, Samanta Ramos; Hansen, Lucca Ortolan

    2014-06-01

    To compare the age at menarche obtained by recall method according to the time elapsed since the event, in order to verify the importance of the recall bias. Were evaluated 1,671 girls (7-18 years) at schools in Campinas-SP regarding the occurrence of menarche by the status quo method (menarche: yes or no) and the recall method (date of menarche, for those who mentioned it). The age at menarche obtained by the status quo method was calculated by logit, which considers the whole group, and the age obtained by the recall method was calculated as the average of the mentioned age at menarche. In this group, the age at menarche was obtained by the difference between the date of the event and the date of birth. Girls who reported menarche (883, 52.8%) were divided into four groups according to the time elapsed since the event. To analyze the results, we used ANOVA and logistic regression for the analysis, with a significance level of 0.05. The age at menarche calculated by logit was 12.14 y/o (95% CI 12.08 to 12.20). Mean ages obtained by recall were: for those who experienced menarche within the previous year 12.26 y/o (±1.14), between > 1-2 years before, 12.29 y (±1.22); between > 2-3 years before, 12.23 y/o (±1.27); and more than 3 years before, 11.55y/o (±1.24), p < 0.001. The age at menarche obtained by the recall method was similar for girls who menstruated within the previous 3 years (and approaches the age calculated by logit); when more than 3 years have passed, the recall bias was significant.

  20. Comparative homology agreement search: An effective combination of homology-search methods

    PubMed Central

    Alam, Intikhab; Dress, Andreas; Rehmsmeier, Marc; Fuellen, Georg

    2004-01-01

    Many methods have been developed to search for homologous members of a protein family in databases, and the reliability of results and conclusions may be compromised if only one method is used, neglecting the others. Here we introduce a general scheme for combining such methods. Based on this scheme, we implemented a tool called comparative homology agreement search (chase) that integrates different search strategies to obtain a combined “E value.” Our results show that a consensus method integrating distinct strategies easily outperforms any of its component algorithms. More specifically, an evaluation based on the Structural Classification of Proteins database reveals that, on average, a coverage of 47% can be obtained in searches for distantly related homologues (i.e., members of the same superfamily but not the same family, which is a very difficult task), accepting only 10 false positives, whereas the individual methods obtain a coverage of 28–38%. PMID:15367730

  1. A blended design in acute care training: similar learning results, less training costs compared with a traditional format.

    PubMed

    Dankbaar, Mary E W; Storm, Diana J; Teeuwen, Irene C; Schuit, Stephanie C E

    2014-09-01

    Introduction There is a demand for more attractive and efficient training programmes in postgraduate health care training. This retrospective study aims to show the effectiveness of a blended versus traditional face-to-face training design. For nurses in postgraduate Acute and Intensive Care training, the effectiveness of a blended course design was compared with a traditional design. Methods In a first pilot study 57 students took a traditional course (2-h lecture and 2-h workshop) and 46 students took a blended course (2-h lecture and 2-h online self-study material). Test results were compared for both groups. After positive results in the pilot study, the design was replicated for the complete programme in Acute and Intensive Care. Now 16 students followed the traditional programme (11 days face-to-face education) and 31 students did the blended programme (7 days face-to-face and 40 h online self-study). An evaluation was done after the pilot and course costs were calculated. Results Results show that the traditional and blended groups were similar regarding the main characteristics and did not differ in learning results for both the pilot and the complete programme. Student evaluations of both designs were positive; however, the blended group were more confident that they had achieved the learning objectives. Training costs were reduced substantially. Conclusion The blended training design offers an effective and attractive training solution, leading to a significant reduction in costs.

  2. Thermosensitivity of a barosensitive Saccharomyces cerevisiae mutant obtained by UV mutagenesis

    NASA Astrophysics Data System (ADS)

    Shigematsu, Toru; Nomura, Kazuki; Nasuhara, Yusuke; Ikarashi, Kenta; Nagai, Gen; Hirayama, Masao; Hayashi, Mayumi; Ueno, Shigeaki; Fujii, Tomoyuki

    2010-12-01

    Using UV mutagenesis, a high pressure (HP)-sensitive (barosensitive) mutant of Saccharomyces cerevisiae was obtained. The mutant strain a924E1 showed a significant loss of viability at HP levels of 175 to 250 MPa at 20 °C compared with the parent strain. This strain also showed a significant loss of viability following heat treatment at 50-58 °C at 0.1 MPa. These results showed that the mutation caused a significant thermosensitivity as well as barosensitivity. The activation volume and activation energy values for the inactivation of strain a924E1 were equivalent to those of the parent strain. This suggested that the mechanism for the HP and thermal inactivation reaction of strain a924E1 was basically the same as that of the parent strain. Strain a924E1 showed no deficiency in growth and fermentation ability as well as auxotrophic property. Although the identification of the genetic sites of mutation introduced is underway, these phenotypes are favorable for the application of HP treatment and heat-assisted HP treatment on fermentation control.

  3. Correlation between DNA ploidy, metaphase high-resolution comparative genomic hybridization results and clinical outcome of synovial sarcoma

    PubMed Central

    2011-01-01

    Background Although synovial sarcoma is the 3rd most commonly occurring mesenchymal tumor in young adults, usually with a highly aggressive clinical course; remarkable differences can be seen regarding the clinical outcome. According to comparative genomic hybridization (CGH) data published in the literature, the simple and complex karyotypes show a correlation between the prognosis and clinical outcome. In addition, the connection between DNA ploidy and clinical course is controversial. The aim of this study was using a fine-tuning interpretation of our DNA ploidy results and to compare these with metaphase high-resolution CGH (HR-CGH) results. Methods DNA ploidy was determined on Feulgen-stained smears in 56 synovial sarcoma cases by image cytometry; follow up was available in 46 cases (average: 78 months). In 9 cases HR-CGH analysis was also available. Results 10 cases were found DNA-aneuploid, 46 were DNA-diploid by image cytometry. With fine-tuning of the diploid cases according to the 5c exceeding events (single cell aneuploidy), 33 cases were so called "simple-diploid" (without 5c exceeding events) and 13 cases were "complex-diploid"; containing 5c exceeding events (any number). Aneuploid tumors contained large numbers of genetic alterations with the sum gain of at least 2 chromosomes (A-, B- or C-group) detected by HR-CGH. In the "simple-diploid" cases no or few genetic alterations could be detected, whereas the "complex-diploid" samples numerous aberrations (equal or more than 3) could be found. Conclusions Our results show a correlation between the DNA-ploidy, a fine-tuned DNA-ploidy and the HR-CGH results. Furthermore, we found significant correlation between the different ploidy groups and the clinical outcome (p < 0.05). PMID:22053830

  4. COMPARATIVE TOXICITY OF SIZE FRACTIONATED AIRBORNE PARTICULATE MATTER OBTAINED FROM DIFFERENT CITIES IN THE USA

    EPA Science Inventory

    This paper is the result of a collaboration to assess effects of size fractionated PM from different locations on murine pulmonary inflammatory responses. In the course of this, they also determined the chemical makeup of each of the samples.

  5. An exploration of how Mexican American WIC mothers obtain information about behaviors associated with childhood obesity risk

    PubMed Central

    Cole, Suzanne M.; McKenney-Shubert, Shannon J.; Jones, Sonya J.; Peterson, Karen E.

    2016-01-01

    Objective To explore how a sample of Mexican American mothers with preschool-aged children recruited from a Midwestern WIC clinic obtain information about 4 behaviors associated with childhood obesity risk: eating, physical activity, screen time and sleep. Methods One-on-1, structured interviews, in which participants were asked how they communicated with family, learned to take care of their first infant and obtained information about the 4 targeted behaviors for their preschool-aged child. Setting An urban WIC clinic in the Midwest. Participants Forty Mexican-descent WIC mothers with children ages 3–4. Phenomenon of Interest Exposure to information about the 4 targeted behaviors among Mexican-descent mothers participating in WIC. Analysis Quantitative and qualitative data were used to characterize and compare across participants. Results Participants primarily obtained information from their child’s maternal grandmother during their first child’s infancy and from health professionals for their preschool-aged child. Participants typically obtained information through interpersonal communication, television and magazines. Participants were most interested in healthy eating information and least interested in screen time information. Some participants did not seek information. Conclusions Participants engaged in different patterns of information seeking across their child’s development and the 4 behaviors, suggesting that future research should be behaviorally specific. Findings from this study suggest several hypotheses to test in future research. PMID:27876321

  6. Evaluation of two transport aircraft and several ground test vehicle friction measurements obtained for various runway surface types and conditions. A summary of test results from joint FAA/NASA Runway Friction Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.; Vogler, William A.; Baldasare, Paul

    1990-01-01

    Tests with specially instrumented NASA Boeing 737 and 727 aircraft together with several different ground friction measuring devices were conducted for a variety of runway surface types and conditions. These tests are part of joint FAA/NASA Aircraft/Ground Vehicle Runway Friction Program aimed at obtaining a better understanding of aircraft ground handling performance under adverse weather conditions and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow and ice-covered runway conditions is discussed as well as ground vehicle friction data obtained under similar runway conditions. For a given contaminated runway surface condition, the correlation between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, type and amount of surface contaminant, and ambient temperature are discussed. The effect of surface type on wet friction levels is also evaluated from comparative data collected on grooved and ungrooved concrete and asphalt surfaces.

  7. [Comparative study of three series of neuro-cutaneous flaps used for coverage of leg defects].

    PubMed

    Jecan, C R; Alecu, L; Costan, I S

    2011-01-01

    The purpose of the trial was to compare three groups of neurocutaneous flaps used to cover defects in the calf, in terms of preoperative characteristics and postoperative results. The main objective was to evaluate the effectiveness of surgical method by testing the hypothesis: neurocutaneous flaps can be applied with clinical results comparable to other surgical methods. The results were presented in the text, through graphic figures and tables. Statistical comparisons were performed according to the results obtained from three series of neurocutaneous flaps in terms of demographic characteristics and those describing postoperative results. The results obtained in the three types of flaps were compared with studies published by other authors, confirming the working hypothesis. The most important results are: the neurocutaneous sural flap is a distal pedicled flap with increased vascular resistance; age and co-morbidities may influence the degree of immediate complications but not the final success rate; the covered defect surface (p = 0.035) is higher for the sural and saphenous flap; the number of days of hospitalization is significantly lower than for microsurgical transfer flaps (p = 0.022). The frequency of complications and reintervention rates were similar (p = 0.022). The study concludes that the sural neurocutaneous flap can be used to cover defects of up to 200 cm2 in the calf with similar results to those of microsurgical transfer flaps.

  8. Results of a prospective randomized control trial comparing hydrophilic to uncoated catheters in children with neurogenic bladder.

    PubMed

    DeFoor, William; Reddy, Pramod; Reed, Melissa; VanderBrink, Brian; Jackson, Elizabeth; Zhang, Bin; Denlinger, Julie; Noh, Paul; Minevich, Eugene; Sheldon, Curtis

    2017-08-01

    Children with neurogenic bladder (NGB) often require a lifetime of clean intermittent catheterization (CIC), typically using uncoated catheters (UCs). Hydrophilic catheters (HCs) have lower friction than UCs with reported less damage to the urethra. The purpose of this study is to compare outcomes between these catheters. An investigator-initiated, prospective, randomized clinical trial was conducted to compare HCs versus UCs. Children aged 2-17 years with NGB on CIC were enrolled for 1 year. Block randomization was used. Dexterity scores were obtained in those who perform self-catheterization. Outcomes were UTI, difficulty passing the catheter, urethral injury, and patient satisfaction. Demographic data is presented in the Table. Seventy-eight patients were enrolled. Age and gender were similar between the groups. Fifteen patients in each group performed CIC via an abdominal wall stoma. Eight and 15 patients withdrew from the UC and HC groups, respectively. The HC group overall had more problems with the catheter, mainly difficulty with handling. There were no differences for passing the catheter, pain, hematuria, or urethral injuries. There were two urinary tract infections (UTIs) in two HC patients and 17 UTIs in seven UC patients (p = 0.003). Patients with UTIs in the HC group went from 16% in the previous year to 5% during the study. Three children in the HC group had three or more UTIs in the year before enrollment and none during the study. The patients that completed the study with HC were overall satisfied and many requested to continue with the HC. HCs may decrease the risk of UTI in children with NGB. Urethral complications were low in both groups. Most HC patients were pleased but some found the slippery coating difficult to handle. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  9. [Anxiety in eating disorders: a comparative study].

    PubMed

    Solano Pinto, Natalia; Cano Vindel, Antonio

    2012-01-01

    Scientific literature shows that anxiety is an important factor in eating disorders. The aim of this case-control study was to compare the anxiety manifestations obtained by means of the Anxiety Situations and Responses Inventory of in a clinical sample of 74 females (46, anorexia nervosa; 28, bulimia) to those obtained by a control group (130 girls without disorders). The between-group ANOVA results showed higher anxiety scores in the clinical group with a medium effect size for the anxiety trait, finding a flat profile (within-group ANOVA) for the three response systems (cognitive, physiological and motor) and the four specific anxiety traits (test, interpersonal, phobic, and daily life situations). Moreover, high scores in anxiety involved a greater risk of being diagnosed with an eating disorder in the 8 bivariate comparisons. The estimations were more precise for cognitive anxiety and for the specific interpersonal anxiety trait.

  10. Quantification of active pharmaceutical ingredient and impurities in sildenafil citrate obtained from the Internet

    PubMed Central

    Nutan, Mohammad T.; Dodla, Uday Krishna Reddy

    2014-01-01

    Background: The accessibility of prescription drugs produced outside of the United States, most notably sildenafil citrate (innovator product, Viagra®), has been made much easier by the Internet. Of greatest concern to clinicians and policymakers is product quality and patient safety. The US Food and Drug Administration (FDA) has issued warnings to potential buyers that the safety of drugs purchased from the Internet cannot be guaranteed, and may present a health risk to consumers from substandard products. Objective: The objective of this study was to determine whether generic sildenafil citrate tablets from international markets obtained via the Internet are equivalent to the US innovator product regarding major aspects of pharmaceutical quality: potency, accuracy of labeling, and presence and level of impurities. This will help identify aspects of drug quality that may impact public health risks. Methods: A total of 15 sildenafil citrate tablets were obtained for pharmaceutical analysis: 14 generic samples from international Internet pharmacy websites and the US innovator product. According to US Pharmacopeial guidelines, tablet samples were tested using high-performance liquid chromatography for potency of active pharmaceutical ingredient (API) and levels of impurities (impurities A, B, C, and D). Impurity levels were compared with International Conference on Harmonisation (ICH) limits. Results: Among the 15 samples, 4 samples possessed higher impurity B levels than the ICH qualification threshold, 8 samples possessed higher impurity C levels than the ICH qualification threshold, and 4 samples possessed more than 1% impurity quantity of maximum daily dose (MDD). For API, 6 of the samples failed to fall within the 5% assay limit. Conclusions: Quality assurance tests are often used to detect formulation defects of drug products during the manufacturing and/or storage process. Results suggest that manufacturing standards for sildenafil citrate generic drug

  11. Working harder to obtain more snack foods when wanting to eat less.

    PubMed

    Giesen, Janneke C A H; Havermans, Remco C; Nederkoorn, Chantal; Strafaci, Silvana; Jansen, Anita

    2009-01-01

    This study investigates individual differences in the reinforcing value of snack food. More specifically, it was investigated whether differences in restraint status are associated with differences in working for high-caloric snack food. Thirty-six unrestrained non-dieters, twenty restrained non-dieters and fifteen current dieters performed a concurrent schedules task in which they had the option to work for points for either snack food or fruit and vegetables. By progressively increasing the "price" of the snack foods (i.e., the amount of work required to obtain extra snack points) the relative reinforcing value of snack food was determined. As hypothesized, restrained non-dieters worked harder and current dieters worked less hard to obtain snack food as compared to unrestrained non-dieters.

  12. Monoscopic photogrammetry to obtain 3D models by a mobile device: a method for making facial prostheses.

    PubMed

    Salazar-Gamarra, Rodrigo; Seelaus, Rosemary; da Silva, Jorge Vicente Lopes; da Silva, Airton Moreira; Dib, Luciano Lauria

    2016-05-25

    The aim of this study is to present the development of a new technique to obtain 3D models using photogrammetry by a mobile device and free software, as a method for making digital facial impressions of patients with maxillofacial defects for the final purpose of 3D printing of facial prostheses. With the use of a mobile device, free software and a photo capture protocol, 2D captures of the anatomy of a patient with a facial defect were transformed into a 3D model. The resultant digital models were evaluated for visual and technical integrity. The technical process and resultant models were described and analyzed for technical and clinical usability. Generating 3D models to make digital face impressions was possible by the use of photogrammetry with photos taken by a mobile device. The facial anatomy of the patient was reproduced by a *.3dp and a *.stl file with no major irregularities. 3D printing was possible. An alternative method for capturing facial anatomy is possible using a mobile device for the purpose of obtaining and designing 3D models for facial rehabilitation. Further studies must be realized to compare 3D modeling among different techniques and systems. Free software and low cost equipment could be a feasible solution to obtain 3D models for making digital face impressions for maxillofacial prostheses, improving access for clinical centers that do not have high cost technology considered as a prior acquisition.

  13. Structure and properties of composite iron-based coatings obtained by the electromechanical technique

    NASA Astrophysics Data System (ADS)

    Dubinskii, N. A.

    2007-09-01

    The influence of the electrolyte temperature and current density on the content of inclusions of powder particles in composite coatings obtained by the electrochemical technique has been investigated. It has been found that the wear resistance of iron coatings with inclusions of powder particles of aluminum, kaolin, and calcium silicate increases from 5 to 10 times compared to coating without inclusions of disperse particles, and the friction coefficient therewith decreases from 0.097 to 0.026. It has been shown that the mechanical properties of iron obtained by the method of electrochemical deposition depend on their fine structure. The regimes of deposition of iron-based coatings have been optimized.

  14. Electrochemical Cell for Obtaining Oxygen from Carbon Dioxide Atmospheres

    NASA Technical Reports Server (NTRS)

    Hooker, Matthew; Rast, H. Edward; Rogers, Darren K.; Borja, Luis; Clark, Kevin; Fleming, Kimberly; Mcgurren, Michael; Oldaker, Tom; Sweet, Nanette

    1989-01-01

    To support human life on the Martian surface, an electrochemical device will be required to obtain oxygen from the carbon dioxide rich atmosphere. The electrolyte employed in such a device must be constructed from extremely thin, dense membranes to efficiently acquire the oxygen necessary to support life. A forming process used industrially in the production of multilayer capacitors and electronic substrates was adapted to form the thin membranes required. The process, known as the tape casting, involves the suspension consisting of solvents and binders. The suspension is passed under a blade, resulting in the production of ceramic membranes between 0.1 and 0.5 mm thick. Once fired, the stabilized zirconia membranes were assembled into the cell design by employing a zirconium phosphate solution as the sealing agent. The resulting ceramic-to-ceramic seals were found to be structurally sound and gas-tight. Furthermore, by using a zirconia-based solution to assemble the cell, the problem of a thermal expansion mismatch was alleviated. By adopting an industrial forming process to produce thin membranes, an electrochemical cell for obtaining oxygen from carbon dioxide was produced. The proposed cell design is unique in that it does not require a complicated manifold system for separating the various gases present in this process, nor does it require a series of complex electrical connections. Thus, the device can reliably obtain the vital oxygen supply from the toxic carbon dioxide atmosphere.

  15. Novel bismuth tri-iodide nanostructures obtained by the hydrothermal method and electron beam irradiation

    NASA Astrophysics Data System (ADS)

    Aguiar, Ivana; Olivera, Alvaro; Mombrú, Maia; Bentos Pereira, Heinkel; Fornaro, Laura

    2017-01-01

    Bismuth tri-iodide is a layered compound semiconductor which has suitable properties as material for ionizing radiation detection devices. Monocrystals and polycrystalline thin films have been studied for this application, but only recently, the development of nanostructures of this compound has emerged as an interesting alternative for using such nanostructures in new types of radiation detectors or for including them in other applications. Considering this, we present in this work BiI3 nanoparticles successfully synthesized by the hydrothermal method, using a Teflon-lined stainless steel autoclave, at a temperature of 180 °C during 8-20 h, with BiCl3 and NaI as source materials. We characterized the nanoparticles by X-ray diffraction (XRD), transmission electron microscopy (TEM) and electron dispersive spectroscopy (EDS). We obtained small rounded or hexagonal particles (10-20 nm in size) and larger structures. The maximum orientation of the nanostructures is along the (0 0 l) family planes and occurs after 16 h of synthesis, which arises as the best condition for obtaining BiI3 oriented nanostructures. When a 100 kV TEM electron beam was converged on the larger structures, we obtained highly oriented BiI3 hexagonal and rod shaped nanostructures. We found that particles' shape does not depend on the synthesis time. In addition, results were compared with the ones obtained for nanoparticles synthesized from solution. The present work is an advance in the synthesis of BiI3 nanostructures by the hydrothermal method, and is also the first step on seeking the amenable control of morphology and size of such structures using electron beam irradiation. This last process may be particularly appropriate for producing nanostructures for future applications in new devices.

  16. An effect size filter improves the reproducibility in spectral counting-based comparative proteomics.

    PubMed

    Gregori, Josep; Villarreal, Laura; Sánchez, Alex; Baselga, José; Villanueva, Josep

    2013-12-16

    The microarray community has shown that the low reproducibility observed in gene expression-based biomarker discovery studies is partially due to relying solely on p-values to get the lists of differentially expressed genes. Their conclusions recommended complementing the p-value cutoff with the use of effect-size criteria. The aim of this work was to evaluate the influence of such an effect-size filter on spectral counting-based comparative proteomic analysis. The results proved that the filter increased the number of true positives and decreased the number of false positives and the false discovery rate of the dataset. These results were confirmed by simulation experiments where the effect size filter was used to evaluate systematically variable fractions of differentially expressed proteins. Our results suggest that relaxing the p-value cut-off followed by a post-test filter based on effect size and signal level thresholds can increase the reproducibility of statistical results obtained in comparative proteomic analysis. Based on our work, we recommend using a filter consisting of a minimum absolute log2 fold change of 0.8 and a minimum signal of 2-4 SpC on the most abundant condition for the general practice of comparative proteomics. The implementation of feature filtering approaches could improve proteomic biomarker discovery initiatives by increasing the reproducibility of the results obtained among independent laboratories and MS platforms. Quality control analysis of microarray-based gene expression studies pointed out that the low reproducibility observed in the lists of differentially expressed genes could be partially attributed to the fact that these lists are generated relying solely on p-values. Our study has established that the implementation of an effect size post-test filter improves the statistical results of spectral count-based quantitative proteomics. The results proved that the filter increased the number of true positives whereas decreased

  17. Analysis of the Quality of Information Obtained About Uterine Artery Embolization From the Internet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tavare, Aniket N.; Alsafi, Ali, E-mail: ali.alsafi03@imperial.ac.uk; Hamady, Mohamad S.

    Purpose: The Internet is widely used by patients to source health care-related information. We sought to analyse the quality of information available on the Internet about uterine artery embolization (UAE). Materials and Methods: We searched three major search engines for the phrase 'uterine artery embolization' and compiled the top 50 results from each engine. After excluding repeated sites, scientific articles, and links to documents, the remaining 50 sites were assessed using the LIDA instrument, which scores sites across the domains of accessibility, usability, and reliability. The Fleisch reading ease score (FRES) was calculated for each of the sites. Finally, wemore » checked the country of origin and the presence of certification by the Health On the Net Foundation (HONcode) as well as their effect on LIDA and FRES scores.ResultsThe following mean scores were obtained: accessibility 48/60 (80%), usability 42/54 (77%), reliability 20/51 (39%), total LIDA 110/165 (67%), and FRES 42/100 (42%). Nine sites had HONcode certification, and this was associated with significantly greater (p < 0.05) reliability and total LIDA and FRES scores. When comparing sites between United Kingdom and United States, there was marked variation in the quality of results obtained when searching for information on UAE (p < 0.05). Conclusion: In general, sites were well designed and easy to use. However, many scored poorly on the reliability of their information either because they were produced in a non-evidence-based way or because they lacking currency. It is important that patients are guided to reputable, location-specific sources of information online, especially because prominent search engine rank does not guarantee reliability of information.« less

  18. Physical Conditions in the Solar Corona Derived from the Total Solar Eclipse Observations obtained on 2017 August 21 Using a Polarization Camera

    NASA Astrophysics Data System (ADS)

    Gopalswamy, N.; Yashiro, Seiji; Reginald, Nelson; Thakur, Neeharika; Thompson, Barbara J.; Gong, Qian

    2018-01-01

    We present preliminary results obtained by observing the solar corona during the 2017 August 21 total solar eclipse using a polarization camera mounted on an eight-inch Schmidt-Cassegrain telescope. The observations were made from Madras Oregon during 17:19 to 17:21 UT. Total and polarized brightness images were obtained at four wavelengths (385, 398.5, 410, and 423 nm). The polarization camera had a polarization mask mounted on a 2048x2048 pixel CCD with a pixel size of 7.4 microns. The resulting images had a size of 975x975 pixels because four neighboring pixels were summed to yield the polarization and total brightness images. The ratio of 410 and 385 nm images is a measure of the coronal temperature, while that at 423 and 398.5 nm images is a measure of the coronal flow speed. We compared the temperature map from the eclipse observations with that obtained from the Solar Dynamics Observatory’s Atmospheric Imaging Assembly images at six EUV wavelengths, yielding consistent temperature information of the corona.

  19. The Role of Comparative Pedagogy in Evaluating Education Systems of Different Countries

    ERIC Educational Resources Information Center

    Hnatiuk, Michal

    2017-01-01

    The article presents the definition of comparative pedagogy according to comparisons from different parts of the world. The subject of the pedagogical sub-disciplinary study, which in its own particular way relates to the research method, has been presented. The obtained results provide the basis for the argument that the scope of comparative…

  20. Acceleration and torque feedback for robotic control - Experimental results

    NASA Technical Reports Server (NTRS)

    Mclnroy, John E.; Saridis, George N.

    1990-01-01

    Gross motion control of robotic manipulators typically requires significant on-line computations to compensate for nonlinear dynamics due to gravity, Coriolis, centripetal, and friction nonlinearities. One controller proposed by Luo and Saridis avoids these computations by feeding back joint acceleration and torque. This study implements the controller on a Puma 600 robotic manipulator. Joint acceleration measurement is obtained by measuring linear accelerations of each joint, and deriving a computationally efficient transformation from the linear measurements to the angular accelerations. Torque feedback is obtained by using the previous torque sent to the joints. The implementation has stability problems on the Puma 600 due to the extremely high gains inherent in the feedback structure. Since these high gains excite frequency modes in the Puma 600, the algorithm is modified to decrease the gain inherent in the feedback structure. The resulting compensator is stable and insensitive to high frequency unmodeled dynamics. Moreover, a second compensator is proposed which uses acceleration and torque feedback, but still allows nonlinear terms to be fed forward. Thus, by feeding the increment in the easily calculated gravity terms forward, improved responses are obtained. Both proposed compensators are implemented, and the real time results are compared to those obtained with the computed torque algorithm.

  1. Deploying and sharing U-Compare workflows as web services.

    PubMed

    Kontonatsios, Georgios; Korkontzelos, Ioannis; Kolluru, Balakrishna; Thompson, Paul; Ananiadou, Sophia

    2013-02-18

    U-Compare is a text mining platform that allows the construction, evaluation and comparison of text mining workflows. U-Compare contains a large library of components that are tuned to the biomedical domain. Users can rapidly develop biomedical text mining workflows by mixing and matching U-Compare's components. Workflows developed using U-Compare can be exported and sent to other users who, in turn, can import and re-use them. However, the resulting workflows are standalone applications, i.e., software tools that run and are accessible only via a local machine, and that can only be run with the U-Compare platform. We address the above issues by extending U-Compare to convert standalone workflows into web services automatically, via a two-click process. The resulting web services can be registered on a central server and made publicly available. Alternatively, users can make web services available on their own servers, after installing the web application framework, which is part of the extension to U-Compare. We have performed a user-oriented evaluation of the proposed extension, by asking users who have tested the enhanced functionality of U-Compare to complete questionnaires that assess its functionality, reliability, usability, efficiency and maintainability. The results obtained reveal that the new functionality is well received by users. The web services produced by U-Compare are built on top of open standards, i.e., REST and SOAP protocols, and therefore, they are decoupled from the underlying platform. Exported workflows can be integrated with any application that supports these open standards. We demonstrate how the newly extended U-Compare enhances the cross-platform interoperability of workflows, by seamlessly importing a number of text mining workflow web services exported from U-Compare into Taverna, i.e., a generic scientific workflow construction platform.

  2. 38 CFR 21.5725 - Obtaining benefits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Obtaining benefits. 21... benefits. (a) Actions required of the individual. In order to obtain benefits under the educational assistance and subsistence allowance program, an individual must— (1) File a claim for benefits with VA, and...

  3. 38 CFR 21.5725 - Obtaining benefits.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Obtaining benefits. 21... benefits. (a) Actions required of the individual. In order to obtain benefits under the educational assistance and subsistence allowance program, an individual must— (1) File a claim for benefits with VA, and...

  4. 38 CFR 21.5725 - Obtaining benefits.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Obtaining benefits. 21... benefits. (a) Actions required of the individual. In order to obtain benefits under the educational assistance and subsistence allowance program, an individual must— (1) File a claim for benefits with VA, and...

  5. 38 CFR 21.5725 - Obtaining benefits.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Obtaining benefits. 21... benefits. (a) Actions required of the individual. In order to obtain benefits under the educational assistance and subsistence allowance program, an individual must— (1) File a claim for benefits with VA, and...

  6. 38 CFR 21.5725 - Obtaining benefits.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Obtaining benefits. 21... benefits. (a) Actions required of the individual. In order to obtain benefits under the educational assistance and subsistence allowance program, an individual must— (1) File a claim for benefits with VA, and...

  7. [Lymphoscintigrams with anatomical landmarks obtained with vector graphics].

    PubMed

    Rubini, Giuseppe; Antonica, Filippo; Renna, Maria Antonia; Ferrari, Cristina; Iuele, Francesca; Stabile Ianora, Antonio Amato; Losco, Matteo; Niccoli Asabella, Artor

    2012-11-01

    Nuclear medicine images are difficult to interpret because they do not include anatomical details. The aim of this study was to obtain lymphoscintigrams with anatomical landmarks that could be easily interpreted by General Physicians. Traditional lymphoscintigrams were processed with Adobe© Photoshop® CS6 and converted into vector images created by Illustrator®. The combination with a silhouette vector improved image interpretation, without resulting in longer radiation exposure or acquisition times.

  8. Quantitative radiology: automated CT liver volumetry compared with interactive volumetry and manual volumetry.

    PubMed

    Suzuki, Kenji; Epstein, Mark L; Kohlbrenner, Ryan; Garg, Shailesh; Hori, Masatoshi; Oto, Aytekin; Baron, Richard L

    2011-10-01

    The purpose of this study was to evaluate automated CT volumetry in the assessment of living-donor livers for transplant and to compare this technique with software-aided interactive volumetry and manual volumetry. Hepatic CT scans of 18 consecutively registered prospective liver donors were obtained under a liver transplant protocol. Automated liver volumetry was developed on the basis of 3D active-contour segmentation. To establish reference standard liver volumes, a radiologist manually traced the contour of the liver on each CT slice. We compared the results obtained with automated and interactive volumetry with those obtained with the reference standard for this study, manual volumetry. The average interactive liver volume was 1553 ± 343 cm(3), and the average automated liver volume was 1520 ± 378 cm(3). The average manual volume was 1486 ± 343 cm(3). Both interactive and automated volumetric results had excellent agreement with manual volumetric results (intraclass correlation coefficients, 0.96 and 0.94). The average user time for automated volumetry was 0.57 ± 0.06 min/case, whereas those for interactive and manual volumetry were 27.3 ± 4.6 and 39.4 ± 5.5 min/case, the difference being statistically significant (p < 0.05). Both interactive and automated volumetry are accurate for measuring liver volume with CT, but automated volumetry is substantially more efficient.

  9. The GLOBE Contrail Protocol: Initial Analysis of Results

    NASA Technical Reports Server (NTRS)

    Chambers, Lin; Duda, David

    2004-01-01

    The GLOBE contrail protocol was launched in March 2003 to obtain surface observer reports of contrail occurrence to complement satellite and model studies underway at NASA Langley, among others. During the first year, more than 30,000 ground observations of contrails were submitted to GLOBE. An initial analysis comparing the GLOBE observations to weather prediction model results for relative humidity at flight altitudes is in progress. This paper reports on the findings to date from this effort.

  10. Electrohydrodynamic direct printing on hydrogel: a novel method to obtain fine fibers

    NASA Astrophysics Data System (ADS)

    Liu, Yuanyuan; Jiang, Chen; Liu, Yi; Li, Dongdong; Hu, Qingxi

    2016-09-01

    In this study, we proposed a novel method to obtain fine fibers: electrohydrodynamic (EHD) direct printing PCL on hydrogel. The effects of applied voltage, flow rate, plotting speed, hydrogel viscosity on the EHD direct writing process were investigated to obtain the most appropriate set of process conditions. We also compared the fibers obtained from this method with traditional EHD which deposited on aluminum and ethanol-based collectors. We found that fibers collected on the hydrogel were thinner and exhibited pores on the surface due to the hydrogel's facilitation of organic solvents' volatilization in the PCL fibers, which can benefit the attachment of cells. Besides, in our previous study, we found the freeze-thaw crosslinking process could greatly increase mechanical properties of the hydrogel used in our research, so this integration will not only mimic the composition of ECM which is a composite structure with a combination of fibrous proteins within a gelatinous grounded substance but also improve the mechanical properties of the scaffold. This novel method will broaden the application of EHD technology in the field of tissue engineering and other related areas.

  11. Socio-Political Influences on EFL Motivation and Attitudes: Comparative Surveys of Korean High School Students

    ERIC Educational Resources Information Center

    Kim, Tae-Young

    2010-01-01

    This paper investigates Korean high school students' English learning motivation and attitudes. In this regard, the results of a 2002 study were compared with those of a 2006 study. Questionnaire data were obtained from a total of 1,037 high school students in a major city in South Korea, and the data were compared with those on the students'…

  12. Comparative evaluation of power factor impovement techniques for squirrel cage induction motors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spee, R.; Wallace, A.K.

    1992-04-01

    This paper describes the results obtained from a series of tests of relatively simple methods of improving the power factor of squirrel-cage induction motors. The methods, which are evaluated under controlled laboratory conditions for a 10-hp, high-efficiency motor, include terminal voltage reduction; terminal static capacitors; and a floating'' winding with static capacitors. The test results are compared with equivalent circuit model predictions that are then used to identify optimum conditions for each of the power factor improvement techniques compared with the basic induction motor. Finally, the relative economic value, and the implications of component failures, of the three methods aremore » discussed.« less

  13. ANTIRADICAL AND ANTIMICROBIAL ACTIVITY OF PHENOLIC FRACTIONS OBTAINED FROM HONEYS.

    PubMed

    Mazol, Irena; Sroka, Zbigniew; Sowa, Alina; Ostrowska, Anna; Dryś, Andrzej; Gamian, Andrzej

    2016-01-01

    Honey is a natural product consisting of multiple components which determine its dietary and medicinal properties. In this work there were studied methanol fractions obtained from seven honeys from Lower Silesia (Poland) collected in different seasons of three successive years. Melissopalynologic studies revealed that two of them were polyfloral, and five were classified as monofloral (two buckwheat and three rapes). The amount of phenolic compounds in honeys varied from 0.09 to 0.38 mg per g of honey. Honeys harvested in 2010 were the richest in phenolic compounds and especially rich was buckwheat honey, comparing to 2011- 2012. Determination of antioxidant potential with the DPPH radical revealed that the strongest antiradical activity was exhibited by extracts obtained from polyfloral (1.22 TAU(515/mg)) and buckwheat (1.06 TAU(515lmg)) honeys, while the highest number of antiradical units was observed for rape honey (3.64 TAU(515/g)). Polyphenolic fractions exhibited various bactericidal activities against Klebsiella pneumoniae and Staphylococcus aureus and weak or no activity was observed against Pseudomonas aeruginosa.

  14. Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cubic meters (175 cubic feet) tank

    NASA Technical Reports Server (NTRS)

    Taylor, William J.; Chato, David J.

    1993-01-01

    The NASA Lewis Research Center (NASA/LeRC) have been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 m and 0.142 cubic m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 cubic m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to over predict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

  15. Partition coefficients of methylated DNA bases obtained from free energy calculations with molecular electron density derived atomic charges.

    PubMed

    Lara, A; Riquelme, M; Vöhringer-Martinez, E

    2018-05-11

    Partition coefficients serve in various areas as pharmacology and environmental sciences to predict the hydrophobicity of different substances. Recently, they have also been used to address the accuracy of force fields for various organic compounds and specifically the methylated DNA bases. In this study, atomic charges were derived by different partitioning methods (Hirshfeld and Minimal Basis Iterative Stockholder) directly from the electron density obtained by electronic structure calculations in a vacuum, with an implicit solvation model or with explicit solvation taking the dynamics of the solute and the solvent into account. To test the ability of these charges to describe electrostatic interactions in force fields for condensed phases, the original atomic charges of the AMBER99 force field were replaced with the new atomic charges and combined with different solvent models to obtain the hydration and chloroform solvation free energies by molecular dynamics simulations. Chloroform-water partition coefficients derived from the obtained free energies were compared to experimental and previously reported values obtained with the GAFF or the AMBER-99 force field. The results show that good agreement with experimental data is obtained when the polarization of the electron density by the solvent has been taken into account, and when the energy needed to polarize the electron density of the solute has been considered in the transfer free energy. These results were further confirmed by hydration free energies of polar and aromatic amino acid side chain analogs. Comparison of the two partitioning methods, Hirshfeld-I and Minimal Basis Iterative Stockholder (MBIS), revealed some deficiencies in the Hirshfeld-I method related to the unstable isolated anionic nitrogen pro-atom used in the method. Hydration free energies and partitioning coefficients obtained with atomic charges from the MBIS partitioning method accounting for polarization by the implicit solvation model

  16. Mitochondrial dysfunction in myocardium obtained from clinically normal dogs, clinically normal anesthetized dogs, and dogs with dilated cardiomyopathy.

    PubMed

    Sleeper, Meg M; Rosato, Bradley P; Bansal, Seema; Avadhani, Narayan G

    2012-11-01

    To compare mitochondrial complex I and complex IV activity in myocardial mitochondria of clinically normal dogs, clinically normal dogs exposed to inhalation anesthesia, and dogs affected with dilated cardiomyopathy. Myocardial samples obtained from 21 euthanized dogs (6 clinically normal [control] dogs, 5 clinically normal dogs subjected to inhalation anesthesia with isoflurane prior to euthanasia, 5 dogs with juvenile-onset dilated cardiomyopathy, and 5 dogs with adult-onset dilated cardiomyopathy). Activity of mitochondrial complex I and complex IV was assayed spectrophotometrically in isolated mitochondria from left ventricular tissue obtained from the 4 groups of dogs. Activity of complex I and complex IV was significantly decreased in anesthetized dogs, compared with activities in the control dogs and dogs with juvenile-onset or adult-onset dilated cardiomyopathy. Inhalation anesthesia disrupted the electron transport chain in the dogs, which potentially led to an outburst of reactive oxygen species that caused mitochondrial dysfunction. Inhalation anesthesia depressed mitochondrial function in dogs, similar to results reported in other species. This effect is important to consider when anesthetizing animals with myocardial disease and suggested that antioxidant treatments may be beneficial in some animals. Additionally, this effect should be considered when designing studies in which mitochondrial enzyme activity will be measured. Additional studies that include a larger number of animals are warranted.

  17. Accuracy of electron densities obtained via Koopmans-compliant hybrid functionals

    NASA Astrophysics Data System (ADS)

    Elmaslmane, A. R.; Wetherell, J.; Hodgson, M. J. P.; McKenna, K. P.; Godby, R. W.

    2018-04-01

    We evaluate the accuracy of electron densities and quasiparticle energy gaps given by hybrid functionals by directly comparing these to the exact quantities obtained from solving the many-electron Schrödinger equation. We determine the admixture of Hartree-Fock exchange to approximate exchange-correlation in our hybrid functional via one of several physically justified constraints, including the generalized Koopmans' theorem. We find that hybrid functionals yield strikingly accurate electron densities and gaps in both exchange-dominated and correlated systems. We also discuss the role of the screened Fock operator in the success of hybrid functionals.

  18. Hybrid Biodegradable Hydrogels Obtained from Nanoclay and Carboxymethylcellulose Polysaccharide: Hydrophilic, Kinetic, Spectroscopic and Morphological Properties.

    PubMed

    Nascimento, Denis W S; de Moura, Márcia R; Mattoso, Luiz H C; Aouada, Fauze A

    2017-01-01

    In this paper, series of novel nanocomposite hydrogels based on polyacrylamide (PAAm), carboxymethylcellulose (CMC) and nanoclay were synthesized. Hydrophilic, kinetic, spectroscopic and morphological properties were investigated as function of their constituents. Spectroscopic properties confirmed the obtaining of the nanocomposites. It was also observed that the nanocomposites have walls of pores with a more rugged morphology compared with the morphology of the hydrogel without clay, contributing to repel the water molecules. Besides, the results showed that the velocity and quantity of water uptake may be controlled by adjusting of matrix rigidity, i.e., nanoclay content into polymeric matrix. This behavior is required to future application in agriculture fields, specifically as carrier vehicle in controlled release of agrochemicals. Thus, these nanocomposites have technological application.

  19. Comparing the IRT Pre-equating and Section Pre-equating: A Simulation Study.

    ERIC Educational Resources Information Center

    Hwang, Chi-en; Cleary, T. Anne

    The results obtained from two basic types of pre-equatings of tests were compared: the item response theory (IRT) pre-equating and section pre-equating (SPE). The simulated data were generated from a modified three-parameter logistic model with a constant guessing parameter. Responses of two replication samples of 3000 examinees on two 72-item…

  20. [Health literacy in Czech population results of the comparative representative research].

    PubMed

    Kučera, Zdeněk; Pelikan, Jurgen; Šteflová, Alena

    Health literacy survey was carried out at the end of 2014 in the context of preparation of implementation strategy of the Program Health 2020 in the Czech Republic. The survey was conducted by the National Institute of Public Health with financial support from the Ministry of Health and the Czech WHO office. Sociological survey replicated comparative research conducted in eight EU countries in the first half of this decade. Representative survey in 1037 respondents in the age over 16 years, selected in all regions of the country. The identical methodology as used in the original study was utilized. Health literacy was measured in the areas of health care, disease prevention and health promotion.We found that 59,4 % of respondents showed limited general health literacy; health literacy in health care is proved to be 49.5 % of the population, in the area of disease prevention it was 54.1 % respondents and in health promotion it was even even 64.3 % of respondents. Compared to the other countries surveyed, Czech Republic occupies the eighth, penultimate place. Health literacy is correlated negatively with age and positively with education. We found a strong social gradient of health literacy which rises with social status. Health literacy quite significantly influences the health status and health behaviors.Key words: health literacy, health behaviour, health promotion, social determinants of health.

  1. Overall Survival and Updated Results for Sunitinib Compared With Interferon Alfa in Patients With Metastatic Renal Cell Carcinoma

    PubMed Central

    Motzer, Robert J.; Hutson, Thomas E.; Tomczak, Piotr; Michaelson, M. Dror; Bukowski, Ronald M.; Oudard, Stéphane; Negrier, Sylvie; Szczylik, Cezary; Pili, Roberto; Bjarnason, Georg A.; Garcia-del-Muro, Xavier; Sosman, Jeffrey A.; Solska, Ewa; Wilding, George; Thompson, John A.; Kim, Sindy T.; Chen, Isan; Huang, Xin; Figlin, Robert A.

    2009-01-01

    Purpose A randomized, phase III trial demonstrated superiority of sunitinib over interferon alfa (IFN-α) in progression-free survival (primary end point) as first-line treatment for metastatic renal cell carcinoma (RCC). Final survival analyses and updated results are reported. Patients and Methods Seven hundred fifty treatment-naïve patients with metastatic clear cell RCC were randomly assigned to sunitinib 50 mg orally once daily on a 4 weeks on, 2 weeks off dosing schedule or to IFN-α 9 MU subcutaneously thrice weekly. Overall survival was compared by two-sided log-rank and Wilcoxon tests. Progression-free survival, response, and safety end points were assessed with updated follow-up. Results Median overall survival was greater in the sunitinib group than in the IFN-α group (26.4 v 21.8 months, respectively; hazard ratio [HR] = 0.821; 95% CI, 0.673 to 1.001; P = .051) per the primary analysis of unstratified log-rank test (P = .013 per unstratified Wilcoxon test). By stratified log-rank test, the HR was 0.818 (95% CI, 0.669 to 0.999; P = .049). Within the IFN-α group, 33% of patients received sunitinib, and 32% received other vascular endothelial growth factor–signaling inhibitors after discontinuation from the trial. Median progression-free survival was 11 months for sunitinib compared with 5 months for IFN-α (P < .001). Objective response rate was 47% for sunitinib compared with 12% for IFN-α (P < .001). The most commonly reported sunitinib-related grade 3 adverse events included hypertension (12%), fatigue (11%), diarrhea (9%), and hand-foot syndrome (9%). Conclusion Sunitinib demonstrates longer overall survival compared with IFN-α plus improvement in response and progression-free survival in the first-line treatment of patients with metastatic RCC. The overall survival highlights an improved prognosis in patients with RCC in the era of targeted therapy. PMID:19487381

  2. The reliability and validity of a three-camera foot image system for obtaining foot anthropometrics.

    PubMed

    O'Meara, Damien; Vanwanseele, Benedicte; Hunt, Adrienne; Smith, Richard

    2010-08-01

    The purpose was to develop a foot image capture and measurement system with web cameras (the 3-FIS) to provide reliable and valid foot anthropometric measures with efficiency comparable to that of the conventional method of using a handheld anthropometer. Eleven foot measures were obtained from 10 subjects using both methods. Reliability of each method was determined over 3 consecutive days using the intraclass correlation coefficient and root mean square error (RMSE). Reliability was excellent for both the 3-FIS and the handheld anthropometer for the same 10 variables, and good for the fifth metatarsophalangeal joint height. The RMSE values over 3 days ranged from 0.9 to 2.2 mm for the handheld anthropometer, and from 0.8 to 3.6 mm for the 3-FIS. The RMSE values between the 3-FIS and the handheld anthropometer were between 2.3 and 7.4 mm. The 3-FIS required less time to collect and obtain the final variables than the handheld anthropometer. The 3-FIS provided accurate and reproducible results for each of the foot variables and in less time than the conventional approach of a handheld anthropometer.

  3. Nanostructured Thin Films Obtained from Fischer Aminocarbene Complexes

    PubMed Central

    Lazo-Jiménez, Rosa E.; Ortega-Alfaro, M. Carmen; López-Cortés, José G.; Alvarez-Toledano, Cecilio; Chávez-Carvayar, José Á.; Ignés-Mullol, Jordi; González-Torres, Maykel; Carreón-Castro, Pilar

    2016-01-01

    The synthesis of four amphiphilic organometallic complexes with the general formula RC = M(CO)5NH(CH2)15CH3, where R is a ferrocenyl 2(a-b) or a phenyl 4(a-b) group as a donor moiety and a Fischer carbene of chromium (0) or tungsten (0) as an acceptor group, are reported. These four push-pull systems formed Langmuir (L) monolayers at the air-water interface, which were characterized by isotherms of surface pressure versus molecular area and compression/expansion cycles (hysteresis curves); Brewster angle microscopic images were also obtained. By using the Langmuir–Blodgett (LB) method, molecular monolayers were transferred onto glass substrates forming Z-type multilayers. LB films were characterized through ultraviolet-visible spectroscopy, atomic force microscopy and X-ray diffraction techniques. Results indicated that films obtained from 2b complex [(Ferrocenyl)(hexadecylamine)methylidene] pentacarbonyl tungsten (0) are the most stable and homogeneous; due to their properties, these materials may be incorporated into organic electronic devices. PMID:28773289

  4. Individual differences and subjective workload assessment - Comparing pilots to nonpilots

    NASA Technical Reports Server (NTRS)

    Vidulich, Michael A.; Pandit, Parimal

    1987-01-01

    Results by two groups of subjects, pilots and nonpilots, for two subjective workload assessment techniques (the SWAT and NASA-TLX tests) intended to evaluate individual differences in the perception and reporting of subjective workload are compared with results obtained for several traditional personality tests. The personality tests were found to discriminate between the groups while the workload tests did not. It is concluded that although the workload tests may provide useful information with respect to the interaction between tasks and personality, they are not effective as pure tests of individual differences.

  5. For reliable urine cultures in the detection of complicated urinary tract infection, do we use urine specimens obtained with urethral catheter or a nephrostomy tube?

    PubMed

    Dede, Gülay; Deveci, Özcan; Dede, Onur; Utanğac, Mazhar; Dağgulli, Mansur; Penbegül, Necmettin; Hatipoğlu, Namık Kemal

    2016-12-01

    The aim of this study was to compare the results of urine cultures obtained either from urethral, and percutaneous nephrostomy (PCN) catheters. This study included 328 consecutive patients that underwent PCN at our institution with complicated urinary tract infections (UTIs) between July 2010 and April 2015. Results of urine cultures obtained from the urethral and nephrostomy catheters were compared. This study included 152 male and 176 female patients. Mean age of the patients was 46.2±24.3 years. The main indications were obstructive uropathy due to urolithiasis complicated with pyonephrosis 145 (44%), malignant disease (n=87; 26%), pregnancy (n=26; 8%), and anatomical abnormality (n=23; 7%). One hundred and twenty three patients had diabetes mellitus. The most common causative organisms were Escherichia coli , Klebsiella pneumoniae , and Pseudomonas aeruginosa . Blood cultures showed the same results for the PCN and bladder urine cultures. The bladder urine culture was positive in 304 patients, while the PCN urine culture in 314 patients. PCN is an important treatment for the management of pyonephrosis. Cultures from the PCN yield valuable information that is not available from urethral urine cultures, and is a guiding tool for antibiotic therapy selection.

  6. Cost-effectiveness of dronedarone and standard of care compared with standard of care alone: US results of an ATHENA lifetime model.

    PubMed

    Reynolds, Matthew R; Nilsson, Jonas; Akerborg, Orjan; Jhaveri, Mehul; Lindgren, Peter

    2013-01-01

    The first antiarrhythmic drug to demonstrate a reduced rate of cardiovascular hospitalization in atrial fibrillation/flutter (AF/AFL) patients was dronedarone in a placebo-controlled, double-blind, parallel arm Trial to assess the efficacy of dronedarone 400 mg bid for the prevention of cardiovascular Hospitalization or death from any cause in patiENts with Atrial fibrillation/atrial flutter (ATHENA trial). The potential cost-effectiveness of dronedarone in this patient population has not been reported in a US context. This study assesses the cost-effectiveness of dronedarone from a US health care payers' perspective. ATHENA patient data were applied to a patient-level health state transition model. Probabilities of health state transitions were derived from ATHENA and published data. Associated costs used in the model (2010 values) were obtained from published sources when trial data were not available. The base-case model assumed that patients were treated with dronedarone for the duration of ATHENA (mean 21 months) and were followed over a lifetime. Cost-effectiveness, from the payers' perspective, was determined using a Monte Carlo microsimulation (1 million fictitious patients). Dronedarone plus standard care provided 0.13 life years gained (LYG), and 0.11 quality-adjusted life years (QALYs), over standard care alone; cost/QALY was $19,520 and cost/LYG was $16,930. Compared to lower risk patients, patients at higher risk of stroke (Congestive heart failure, history of Hypertension, Age ≥ 75 years, Diabetes mellitus, and past history of Stroke or transient ischemic attack (CHADS(2)) scores 3-6 versus 0) had a lower cost/QALY ($9580-$16,000 versus $26,450). Cost/QALY was highest in scenarios assuming lifetime dronedarone therapy, no cardiovascular mortality benefit, no cost associated with AF/AFL recurrence on standard care, and when discounting of 5% was compared with 0%. By extrapolating the results of a large, multicenter, randomized clinical trial (ATHENA

  7. Usefulness of in-house obtained recombinant proteins Yop of Yersinia enterocolitica as highly specific antigens in ELISA and recom-dot performed in the serodiagnosis of yersiniosis.

    PubMed

    Rastawicki, Waldemar; Smietafiska, Karolina; Chrost, Anna; Wolkowicz, Tomasz; Rokosz-Chudziak, Natalia

    Proper analysis of the human immune response is crucial in the laboratory diagnosis of many bacterial infections-The current serological diagnosis of yersiniosis often is carried out using ELISA with native antigens. However, recombinant proteins increase the specificity of the serological assays, particularly in patients with chronic, non- specific infections. The aim of the present study was to evaluate the usefulness of in-house obtained recombinant proteins Yop of Yersinia enterocolitica as highly specific antigens in ELISA and recom-dot performed in the serodiagnosis of yersiniosis. Recombinant YopD, YopB, YopE and V-Ag proteins of Y enterocolitica were expressing in E. coli BL21 (DE3) using the pET-30 Ek/LIC expression vector (Novagen). Purification was accomplished by immobilized metal (Ni2) affinity column chromatography (His-trap). The proteins were used as antigens in standard ELISA and recom-dot assay, which was performed on nitrocellulose strips. The study population, used for characterization of the humoral immune response to the recombinant proteins, consisted of 74 patients suspected for Y enterocolitica infection and 41 clinically healthy blood donors. Some of the results obtained by ELISA and recom-dot were compared with results obtained by commercial western-blot Yersinia (Virotech). In the group of patients suspected for yersiniosis in clinical investigation the most positive results were obtained in ELISA with the recombinant protein YopD (IgA respectively 25 (42.4%), IgG 41 (69.5%), IgM 24 (40.7%). The percentage ofpositive results in the group of blood donors did not exceed 10.0% in IgG and 5.0% in IgA/IgM classes of immunoglobulin. The results obtained in the recom-dot assay showed that among 74 tested serum samples obtained from individuals suspected of yersiniosis the most common IgA, IgG and IgM antibodies were found for recombinant protein YopD (respectively IgG in 60.8%, IgA in 37.8% and IgM in 33.8% of serum samples). IgG antibodies to

  8. Statistical evaluation of fatty acid profile and cholesterol content in fish (common carp) lipids obtained by different sample preparation procedures.

    PubMed

    Spiric, Aurelija; Trbovic, Dejana; Vranic, Danijela; Djinovic, Jasna; Petronijevic, Radivoj; Matekalo-Sverak, Vesna

    2010-07-05

    Studies performed on lipid extraction from animal and fish tissues do not provide information on its influence on fatty acid composition of the extracted lipids as well as on cholesterol content. Data presented in this paper indicate the impact of extraction procedures on fatty acid profile of fish lipids extracted by the modified Soxhlet and ASE (accelerated solvent extraction) procedure. Cholesterol was also determined by direct saponification method, too. Student's paired t-test used for comparison of the total fat content in carp fish population obtained by two extraction methods shows that differences between values of the total fat content determined by ASE and modified Soxhlet method are not statistically significant. Values obtained by three different methods (direct saponification, ASE and modified Soxhlet method), used for determination of cholesterol content in carp, were compared by one-way analysis of variance (ANOVA). The obtained results show that modified Soxhlet method gives results which differ significantly from the results obtained by direct saponification and ASE method. However the results obtained by direct saponification and ASE method do not differ significantly from each other. The highest quantities for cholesterol (37.65 to 65.44 mg/100 g) in the analyzed fish muscle were obtained by applying direct saponification method, as less destructive one, followed by ASE (34.16 to 52.60 mg/100 g) and modified Soxhlet extraction method (10.73 to 30.83 mg/100 g). Modified Soxhlet method for extraction of fish lipids gives higher values for n-6 fatty acids than ASE method (t(paired)=3.22 t(c)=2.36), while there is no statistically significant difference in the n-3 content levels between the methods (t(paired)=1.31). The UNSFA/SFA ratio obtained by using modified Soxhlet method is also higher than the ratio obtained using ASE method (t(paired)=4.88 t(c)=2.36). Results of Principal Component Analysis (PCA) showed that the highest positive impact to

  9. SU-E-I-53: Variation in Measurements of Breast Skin Thickness Obtained Using Different Imaging Modalities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, U; Kumaraswamy, N; Markey, M

    Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution,more » with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality.« less

  10. Water vapour condensation in a partly closed structure. Comparison between results obtained with an inside wet or dry bottom wall

    NASA Astrophysics Data System (ADS)

    Batina, Jean; Peyrous, René

    2018-04-01

    We are interested in the determination of the more significant parameters acting on the water vapour condensation in a partly closed structure, submitted to external constraints (temperature and humidity), in view to recover the generated droplets as an additional source of potable water. External temperature variations, by inducing temperature differences between outside and inside of the structure, lead to convective movements and thermal variations inside this structure. Through an orifice, these movements permit a renewing of the humid inner air and can lead to the condensation of the water vapour initially contained in the inner air volume and/or on the walls. With the above hypotheses, and by using a numerical simulation [1] based on the ambient air characteristics and a finite volumes method, it appears that condensed water quantities are mainly depending on the boundary conditions imposed. These conditions are: 1) dimensions of the structure; 2) external temperature and relative hygrometry; 3) the phase φ (T/RH) linking thermal and hydrometric conditions; 4) the air renewing and its hygrometry for each phase; and 5) for each case, the fact that the inside bottom wall can be wet or dry. The resulting condensed water vapour quantities obtained, for the width section, point out clearly that they are very depending on this phase φ (T/RH) which appears as the more significant parameter and can be modified by the presence or not of a thin layer of water vapour on the inside bottom wall. Condensation phenomenon could be increased if φ could be optimized.

  11. Seasonal differences in the subjective assessment of outdoor thermal conditions and the impact of analysis techniques on the obtained results

    NASA Astrophysics Data System (ADS)

    Kántor, Noémi; Kovács, Attila; Takács, Ágnes

    2016-11-01

    Wide research attention has been paid in the last two decades to the thermal comfort conditions of different outdoor and semi-outdoor urban spaces. Field studies were conducted in a wide range of geographical regions in order to investigate the relationship between the thermal sensation of people and thermal comfort indices. Researchers found that the original threshold values of these indices did not describe precisely the actual thermal sensation patterns of subjects, and they reported neutral temperatures that vary among nations and with time of the year. For that reason, thresholds of some objective indices were rescaled and new thermal comfort categories were defined. This research investigates the outdoor thermal perception patterns of Hungarians regarding the Physiologically Equivalent Temperature ( PET) index, based on more than 5800 questionnaires. The surveys were conducted in the city of Szeged on 78 days in spring, summer, and autumn. Various, frequently applied analysis approaches (simple descriptive technique, regression analysis, and probit models) were adopted to reveal seasonal differences in the thermal assessment of people. Thermal sensitivity and neutral temperatures were found to be significantly different, especially between summer and the two transient seasons. Challenges of international comparison are also emphasized, since the results prove that neutral temperatures obtained through different analysis techniques may be considerably different. The outcomes of this study underline the importance of the development of standard measurement and analysis methodologies in order to make future studies comprehensible, hereby facilitating the broadening of the common scientific knowledge about outdoor thermal comfort.

  12. A comparative study of fissure sealants Helioseal Clear Chroma and Delton FS(+): 3 year results.

    PubMed

    Kargul, B; Tanboga, I; Gulman, N

    2009-12-01

    To evaluate the retention rates of a resin based colour changing fissure sealant (Helioseal Clear Chroma; Ivoclar Vivadent AG Schaan, Liechtenstein) compared with a coloured resin based fluoride fissure sealant (Delton FS(+); Dentsply De Trey GmbH,Konstanz,Germany). The fissure sealants (FS) were placed on all 4 caries-free first permanent molars of 31 children aged 6-9 years, using a half mouth experimental design by a paediatric dentist according to the manufacturers' instructions. A total of 121 FS were placed at baseline. Teeth were evaluated at 3 month intervals for 36 months where a preventive program including topical fluoride application was applied. Retention rates for 36 months showed a differences between Delton FS(+) and Helioseal Clear Chroma that were statistically significant (p<0.05). Delton FS(+) had total retention rate of 30.4% for 36 months compared with Helioseal Clear Chroma at 10.8% for the same evaluation period. Although Delton FS(+) showed significantly better results than Helioseal Clear Chroma for the evaluation periods, there were no statistically significant differences between Delton FS(+) (90.7%) and Helioseal Clear Chroma (80.4%) with respect to caries incidence at 36 months(p>0.05). Delton FS(+) showed a better complete retention rate for occlusal FS at one year. Both FS were aesthetically acceptable and easy to see during application and follow-up periods and gave significant protection from occlusal decay.

  13. DOT/NASA comparative assessment of Brayton engines for guideway vehicles and busses. Volume 2: Analysis and results

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Gas turbine engines were assessed for application to hear duty transportation. A summary of the assumptions, applications, and methods of analysis is included along with a discussion of the approach taken, the technical program flow chart, and weighting criteria used for performance evaluation. The various engines are compared on the bases of weight, performance, emissions and noise, technology status, and growth potential. The results of the engine screening phase and the conceptual design phase are presented.

  14. The Escompte - Marseille 2001 International Field Experiment: Ground Based and Lidar Results Obtained At St. Chamas By The Epfl Mobile Laboratory

    NASA Astrophysics Data System (ADS)

    Balin, I.; Jimenez, R.; Simeonov, V.; Ristori, P.; Navarette, M.; van den Bergh, H.; Calpini, B.

    The assessment of the air pollution problems in term of understanding of the non- linear chemical mechanisms, the transport or the meteorological processes, and the choice of the abatement strategies could be based on the air pollution models. Nowa- days, very few of these models were validated due to the lack of 3D measurements. The goal of the ESCOMPTE experiment was to provide such of 3D database in order to constrain the air pollution models. The EPFL-LPA mobile laboratory was part of the ESCOMPTE extensive network and was located on the northern side of the Berre Lake at St.Chamas. In this framework, measurements of the air pollutants (O3, SO2, NOx, polycyclic aromatic hydrocarbons, black carbon and particulate matter of less than 10 microns mean diameter) and meteorological parameters (wind, temperature, pressure and relative humidity) were continuously performed from June 10 to July 13, 2001. They were combined with ground based lidar observations for ozone and aerosol estimation from 100m above ground level up to the free troposphere at ca.7 km agl. This paper will present an overview of the results obtained and will highlight one of the intensive observation period (IOP) during which clean air conditions were initially observed followed by highly polluted air masses during the second half of the IOP.

  15. Collection of relevant results obtained with the ERTS-1 satellite images by the Institute for Space Research (INPE), volume 2. [Brazil

    NASA Technical Reports Server (NTRS)

    Demendonca, F.; Amaral, G.; Gamadealmeida, E. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. Soil resource studies in Brazil have concluded that: areas with agricultural activities appear surrounding urban centers; some areas are suffering a strong erosion action; there exist two drainage systems near Paraguai River and Parana River; and this region possesses great variety of soil types. It is possible to count the number of lakes and sluices as well as their superficial area using a channel 7 photographic enlargement. The great concentration of water bodies along the Jacui River determines the large rice crops. Data concerning regions around Teresina City, Presidente Prudente, Piracicaba City, Dourados, and Tres Marias Dam revealed several characteristics concerning the soil and water resources. Two basic maps were made of the natural vegetation distribution over central eastern Brazil from data ERTS-1 data. One map shows the drainage system, the road system, and cities; while the second shows the natural vegetation. It was possible to identify old reforestation, new reforestation, natural forest in flat lands, and natural forest in rolling lands from the ERTS images. Different pasture plant species could be identified by multispectral remote sensing. Data obtained along different wavelength bands provide essential data for the range manager to evaluate his range and to establish a suitable policy. Hydrographic mapping was done using the ERTS images.

  16. Comparison of Central Corneal Thickness Measurements Obtained by RTVue OCT, Lenstar, Sirius Topography, and Ultrasound Pachymetry in Healthy Subjects.

    PubMed

    Şimşek, Ali; Bilak, Şemsettin; Güler, Mete; Çapkin, Musa; Bilgin, Burak; Reyhan, Ali Hakim

    2016-01-01

    To compare central corneal thickness (CCT) measurement results obtained by RTVue OCT, Lenstar, Sirius topography, and ultrasound pachymetry (UP) (OcuScan RxP Ophthalmic Ultrasound System, Alcon Laboratories) in healthy subjects. 256 eyes of 128 healthy subjects were included in the study. CCT measurements were obtained from the eyes for each subject using the UP, Lenstar, Sirius topography, and RTVue OCT instruments. Ultrasound pachymetry measurements were performed after the eyes were anesthetized with one drop of 0.5% proparacaine hydrochloride and were performed at the same day after 15 minutes after previous measurements. Of 128 participants, 84 were male and 44 were female with a mean age of 33.15 ± 12.95 years (ranging from 18 to 75 years). The mean CCTs for UP, Lenstar, Sirius topography, and RTVue OCT were 535.60 ± 35.15 (440,00-668,00); 532.63 ± 34.44 (449,00-650,00); 526.05 ± 36.45 (314,00-640,00); 525.89 ± 33.21 (437,00-646,00) µm, respectively. The mean CCT measurements were statistically different among the three groups (p = 0.002). CCT measurements obtained using RTVue-OCT were significantly thinner than those obtained using UP (p = 0.009). Sirius CCT measurements were also thinner than UP (p = 0.011). Mean CCT measurements between UP and Lenstar were similar (p = 0.769). Measurements with Lenstar (r = 0.849), Sirius topography (r = 0.883), and RTVue OCT (0.949) were highly correlated with UP measurements. RTVue OCT and Sirius topography significantly underestimated the CCT compared with UP. Although highly correlated, the measurement values with these devices are not directly interchangeable in clinical practice.

  17. Securing recruitment and obtaining informed consent in minority ethnic groups in the UK.

    PubMed

    Lloyd, Cathy E; Johnson, Mark R D; Mughal, Shanaz; Sturt, Jackie A; Collins, Gary S; Roy, Tapash; Bibi, Rukhsana; Barnett, Anthony H

    2008-03-30

    Previous health research has often explicitly excluded individuals from minority ethnic backgrounds due to perceived cultural and communication difficulties, including studies where there might be language/literacy problems in obtaining informed consent. This study addressed these difficulties by developing audio-recorded methods of obtaining informed consent and recording data. This report outlines 1) our experiences with securing recruitment to a qualitative study investigating alternative methods of data collection, and 2) the development of a standardised process for obtaining informed consent from individuals from minority ethnic backgrounds whose main language does not have an agreed written form. Two researchers from South Asian backgrounds recruited adults with Type 2 diabetes whose main language was spoken and not written, to attend a series of focus groups. A screening tool was used at recruitment in order to assess literacy skills in potential participants. Informed consent was obtained using audio-recordings of the patient information and recording patients' verbal consent. Participants' perceptions of this method of obtaining consent were recorded. Recruitment rates were improved by using telephone compared to face-to-face methods. The screening tool was found to be acceptable by all potential participants. Audio-recorded methods of obtaining informed consent were easy to implement and accepted by all participants. Attrition rates differed according to ethnic group. Snowballing techniques only partly improved participation rates. Audio-recorded methods of obtaining informed consent are an acceptable alternative to written consent in study populations where literacy skills are variable. Further exploration of issues relating to attrition is required, and a range of methods may be necessary in order to maximise response and participation rates.

  18. Two different solicitation methods for obtaining information on adverse events associated with methylphenidate in adolescents: a 12-week multicenter, open-label study.

    PubMed

    Lee, Moon-Soo; Lee, Soyoung I; Hong, Sungdo D; Kim, Ji-Hoon; Choi, Jeewook; Joung, Yoo-Sook

    2013-02-01

    We explored two different methods of determining adverse events (AEs) among methylphenidate (MPH)-treated adolescents with attention-deficit/hyperactivity disorder (ADHD). We performed a 12-week open label study of osmotic-release oral system (OROS) MPH in adolescents with ADHD who were recruited from four child and adolescent psychiatric outpatient clinics. The AEs were evaluated via a two-step procedure at weeks 1, 3, 6, and 12. The first step was to ask a general question to subjects and their parents regarding AEs. The second step included an AE evaluation process by the investigators, which was performed using a drug-specific checklist. One-way repeated measures ANOVA were used to compare the number of AEs reported by patients and their parents compared with the number reported by clinicians. This statistical technique was also used to compare the number of AEs reported by various sources (i.e., patients, parents, and clinicians) at weeks 1, 3, 6, and 12. Of the 55 participants (43 males, 12 females) between the ages of 12 and 18 enrolled in this study, 47 participants completed the trial. When the number of AEs reported by patients, parents and clinicians were compared, there were no statistically significant differences. When the numbers of AEs obtained from the three different information sources at each study visit were compared, we noted differences. At week 6, the number of AEs evaluated by clinical investigators was higher than those reported by patients and their parents (p=0.003). Although the results did not reach statistical significance, the number of AEs reported by clinical investigators appeared to be greater than those obtained from patients or parents at weeks 3 and 12. The number of AEs reported by patients and their parents were similar at every visit. There were some differences in the pattern of AEs reported between patients and their parents. Clinicians should supplement the subjective report on AEs from patients or their parents with a

  19. A comparative physical evaluation of four X-ray films.

    PubMed

    Egyed, M; Shearer, D R

    1981-09-01

    In this study, four general purpose radiographic films (Agfa Gevaert Curix RP-1, duPont Cronex 4, Fuji RX, and Kodak XRP-1) were compared using three independent techniques. By examining the characteristic curves for the four films, film speed and contrast were compared over the diagnostically useful density range. These curves were generated using three methods: (1) irradiation of a standard film cassette lined with high-speed screens, covered by a twelve-step aluminum wedge; (2) direct exposure of film strips to an electro-luminescent sensitometer; and (3) direct irradiation of a standard film cassette lined with high-speed screens. The latter technique provided quantitative values for film speed and relative contrast. All three techniques provided virtually properly identical results and indicate that under properly controlled conditions simplified methods of film testing can give results equivalent to those obtained by more sophisticated techniques.

  20. Implications of failure to achieve a result from prenatal maternal serum cell-free DNA testing: a historical cohort study.

    PubMed

    Chan, N; Smet, M-E; Sandow, R; da Silva Costa, F; McLennan, A

    2017-11-01

    To investigate the pregnancy outcomes in a cohort of women who failed to obtain a result in non-invasive prenatal testing (NIPT). Historical cohort study. A multicentre private practice in Sydney, Australia. Women who failed to obtain a result from NIPT (n = 131). The maternal characteristics, antenatal investigations and pregnancy outcomes for these women were compared with those who obtained a result at the same practice and to the general Australian obstetric population. Antenatal investigations: pregnancy-associated plasma protein-A (PAPP-A), free β-human chorionic gonadotrophin (β-hCG), placental growth factor (PlGF), uterine artery pulsatility index (PI), mean arterial pressure (MAP). Pregnancy outcomes: chromosomal abnormality, pre-eclampsia, gestational diabetes, small-for-gestational-age (SGA), preterm delivery. Only 1.1% of NIPT samples failed to return a result. This cohort was significantly older and had significantly increased weight compared with the general Australian obstetric population. Pregnancy outcomes were available for 94% of the cohort. There were significantly higher rates of chromosomal aneuploidies (6.5% versus 0.2%, P < 0.0001), pre-eclampsia (11% versus 1.5%, P < 0.0001) and gestational diabetes (23% versus 7.5%, P < 0.0001) compared with the general obstetric population. Rates of preterm delivery and SGA were elevated but did not reach significance. Antenatal investigations demonstrated decreased PAPP-A MoM (0.75 versus 1.14, P < 0.0001), decreased free β-hCG (0.71 versus 1.01, P < 0.0001) and increased uterine artery PI (1.79 versus 1.65, P = 0.02). Women who fail to obtain a result from NIPT are at increased risk of adverse pregnancy outcomes, in particular chromosomal aneuploidy, gestational diabetes and pre-eclampsia. None received. Women who fail to obtain a result from cell-free DNA NIPT are at increased risk of adverse pregnancy outcomes. © 2017 Royal College of Obstetricians and Gynaecologists.

  1. Recovery of phenotypes obtained by adaptive evolution through inverse metabolic engineering.

    PubMed

    Hong, Kuk-Ki; Nielsen, Jens

    2012-11-01

    In a previous study, system level analysis of adaptively evolved yeast mutants showing improved galactose utilization revealed relevant mutations. The governing mutations were suggested to be in the Ras/PKA signaling pathway and ergosterol metabolism. Here, site-directed mutants having one of the mutations RAS2(Lys77), RAS2(Tyr112), and ERG5(Pro370) were constructed and evaluated. The mutants were also combined with overexpression of PGM2, earlier proved as a beneficial target for galactose utilization. The constructed strains were analyzed for their gross phenotype, transcriptome and targeted metabolites, and the results were compared to those obtained from reference strains and the evolved strains. The RAS2(Lys77) mutation resulted in the highest specific galactose uptake rate among all of the strains with an increased maximum specific growth rate on galactose. The RAS2(Tyr112) mutation also improved the specific galactose uptake rate and also resulted in many transcriptional changes, including ergosterol metabolism. The ERG5(Pro370) mutation only showed a small improvement, but when it was combined with PGM2 overexpression, the phenotype was almost the same as that of the evolved mutants. Combination of the RAS2 mutations with PGM2 overexpression also led to a complete recovery of the adaptive phenotype in galactose utilization. Recovery of the gross phenotype by the reconstructed mutants was achieved with much fewer changes in the genome and transcriptome than for the evolved mutants. Our study demonstrates how the identification of specific mutations by systems biology can direct new metabolic engineering strategies for improving galactose utilization by yeast.

  2. Polarization of the zodiacal light - First results from Skylab

    NASA Technical Reports Server (NTRS)

    Sparrow, J. G.; Weinberg, J. L.; Hahn, R. C.

    1976-01-01

    A brief description is given of the Skylab ten color photoelectric photometer and the programs of measurements made during Skylab missions SL-2 and SL-3. Results obtained on the polarized brightness of zodiacal light at five points on the antisolar hemisphere are discussed and compared with other published data for the north celestial pole, south ecliptic pole, at elongation 90 degrees on the ecliptic, and at two places near the north galactic pole.

  3. Comparative characteristics of quantitative indexes for 18F-FDG uptake and metabolic volume in sequentially obtained PET/MRI and PET/CT.

    PubMed

    Lee, Soo Jin; Paeng, Jin Chul; Goo, Jin Mo; Lee, Jeong Min; Cheon, Gi Jeong; Lee, Dong Soo; Chung, June-Key; Kang, Keon Wook

    2017-04-01

    The purpose of this study was to compare quantitative indexes for fluorine-18 fluorodeoxyglucose uptake and metabolic volume between PET/MRI and PET/CT. Sixty-six patients with solid tumors (32 with lung cancer and 34 with pancreatic cancer) who underwent sequential fluorine-18 fluorodeoxyglucose PET/MRI and PET/CT were retrospectively enrolled. On PET images, maximum and peak standardized uptake values (SUVmax and SUVpeak, respectively), and maximum tumor-to-liver ratio (TLRmax) were measured. Metabolic tumor volume (MTV) and total-lesion glycolysis (TLG) with margin thresholds of 50% SUVmax and SUV 2.5 (MTV50%, MTV2.5; TLG50%, TLG2.5, respectively) were compared between PET/MRI and PET/CT, with patients classified into two groups using imaging protocol (the PET/MRI-first and PET/CT-first groups). There were significant correlations of all tested indexes between PET/MRI and PET/CT (r=0.867-0.987, P<0.001). SUVmax and SUVpeak were lower on PET/MRI regardless of imaging protocol (P<0.001 in the PET/MRI-first group). In contrast, TLRmax exhibited reverse results between the PET/MRI-first and PET/CT-first groups. MTV50% and TLG values varied between PET/MRI and PET/CT, as well as between the PET/MRI-first and PET/CT-first groups. However, MTV2.5 was relatively robust against imaging protocol and modality. There are significant correlations of the quantitative indexes between PET/MRI and PET/CT. However, uptake indexes of SUVmax and SUVpeak are lower on PET/MRI than on PET/CT, and volumetric indexes of MTV50% and TLG values also exhibited significant differences. It may be suggested that TLRmax and MTV2.5 are relatively more appropriate indexes than others when PET/MRI and PET/CT are used interchangeably.

  4. Relation of NDVI obtained from different remote sensing at different space and resolutions sensors in Spanish Dehesas

    NASA Astrophysics Data System (ADS)

    Escribano Rodríguez, Juan; Tarquis, Ana M.; Saa-Requejo, Antonio; Díaz-Ambrona, Carlos G. H.

    2015-04-01

    Satellite data are an important source of information and serve as monitoring crops on large scales. There are several indexes, but the most used for monitoring vegetation is NDVI (Normalized Difference Vegetation Index), calculated from the spectral bands of red (RED) and near infrared (NIR), obtaining the value according to relationship: [(NIR - RED) / (NIR + RED)]. During the years 2010-2013 monthly monitoring was conducted in three areas of Spain (Salamanca, Caceres and Cordoba). Pasture plots were selected and satellite images of two different sensors, DEIMOS-1 and MODIS were obtained. DEIMOS-1 is based on the concept Microsat-100 from Surrey. It is designed for imaging the Earth with a resolution good enough to study terrestrial vegetation cover (20x20 m), although with a wide range of visual field (600 km) to get those images with high temporal resolution. By contrast, MODIS images present a much lower spatial resolution (500x500 m). Indices obtained from both sensors to the same area and date are compared and the results show r2 = 0.56; r2 = 0.65 and r2 = 0.90 for the areas of Salamanca, Cáceres and Cordoba respectively. According to the results obtained show that the NDVI obtained by MODIS is slightly larger than that obtained by the sensor for DEIMOS for same time and area. References J.A. Escribano, C.G.H. Diaz-Ambrona, L. Recuero, M. Huesca, V. Cicuendez, A. Palacios-Orueta y A.M. Tarquis. Aplicacion de Indices de Vegetacion para evaluar la falta de produccion de pastos y montaneras en dehesas. I Congreso Iberico de la Dehesa y el Montado. 6-7 Noviembre, 2013, Badajoz. J.A. Escribano Rodriguez, A.M. Tarquis, C.G. Hernandez Diaz-Ambrona. Pasture Drought Insurance Based on NDVI and SAVI. Geophysical Research Abstracts, 14, EGU2012-13945, 2012. EGU General Assembly 2012. Juan Escribano Rodriguez, Carmelo Alonso, Ana Maria Tarquis, Rosa Maria Benito, Carlos Hernandez Diaz-Ambrona. Comparison of NDVI fields obtained from different remote sensors

  5. Comparative inhibition of rabbit globin mRNA translation by modified antisense oligodeoxynucleotides.

    PubMed Central

    Cazenave, C; Stein, C A; Loreau, N; Thuong, N T; Neckers, L M; Subasinghe, C; Hélène, C; Cohen, J S; Toulmé, J J

    1989-01-01

    We have studied the translation of rabbit globin mRNA in cell free systems (reticulocyte lysate and wheat germ extract) and in microinjected Xenopus oocytes in the presence of anti-sense oligodeoxynucleotides. Results obtained with the unmodified all-oxygen compounds were compared with those obtained when phosphorothioate or alpha-DNA was used. In the wheat germ system a 17-mer sequence targeted to the coding region of beta-globin mRNA was specifically inhibitory when either the unmodified phosphodiester oligonucleotide or its phosphorothioate analogue were used. In contrast no effect was observed with the alpha-oligomer. These results were ascribed to the fact that phosphorothioate oligomers elicit an RNase-H activity comparable to the all-oxygen congeners, while alpha-DNA/mRNA hybrids were a poor substrate. Microinjected Xenopus oocytes followed a similar pattern. The phosphorothioate oligomer was more efficient to prevent translation than the unmodified 17-mer. Inhibition of beta-globin synthesis was observed in the nanomolar concentration range. This result can be ascribed to the nuclease resistance of phosphorothioates as compared to natural phosphodiester linkages, alpha-oligomers were devoid of any inhibitory effect up to 30 microM. Phosphorothioate oligodeoxyribonucleotides were shown to be non-specific inhibitors of protein translation, at concentrations in the micromolar range, in both cell-free systems and oocytes. Non-specific inhibition of translation was dependent on the length of the phosphorothioate oligomer. These non-specific effects were not observed with the unmodified or the alpha-oligonucleotides. Images PMID:2472605

  6. A convolution model for obtaining the response of an ionization chamber in static non standard fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez-Castano, D. M.; Gonzalez, L. Brualla; Gago-Arias, M. A.

    2012-01-15

    Purpose: This work contains an alternative methodology for obtaining correction factors for ionization chamber (IC) dosimetry of small fields and composite fields such as IMRT. The method is based on the convolution/superposition (C/S) of an IC response function (RF) with the dose distribution in a certain plane which includes chamber position. This method is an alternative to the full Monte Carlo (MC) approach that has been used previously by many authors for the same objective. Methods: The readout of an IC at a point inside a phantom irradiated by a certain beam can be obtained as the convolution of themore » dose spatial distribution caused by the beam and the IC two-dimensional RF. The proposed methodology has been applied successfully to predict the response of a PTW 30013 IC when measuring different nonreference fields, namely: output factors of 6 MV small fields, beam profiles of cobalt 60 narrow fields and 6 MV radiosurgery segments. The two-dimensional RF of a PTW 30013 IC was obtained by MC simulation of the absorbed dose to cavity air when the IC was scanned by a 0.6 x 0.6 mm{sup 2} cross section parallel pencil beam at low depth in a water phantom. For each of the cases studied, the results of the IC direct measurement were compared with the corresponding obtained by the C/S method. Results: For all of the cases studied, the agreement between the IC direct measurement and the IC calculated response was excellent (better than 1.5%). Conclusions: This method could be implemented in TPS in order to calculate dosimetry correction factors when an experimental IMRT treatment verification with in-phantom ionization chamber is performed. The miss-response of the IC due to the nonreference conditions could be quickly corrected by this method rather than employing MC derived correction factors. This method can be considered as an alternative to the plan-class associated correction factors proposed recently as part of an IAEA work group on nonstandard field

  7. Comparative analysis of respiratory motion tracking using Microsoft Kinect v2 sensor.

    PubMed

    Silverstein, Evan; Snyder, Michael

    2018-05-01

    To present and evaluate a straightforward implementation of a marker-less, respiratory motion-tracking process utilizing Kinect v2 camera as a gating tool during 4DCT or during radiotherapy treatments. Utilizing the depth sensor on the Kinect as well as author written C# code, respiratory motion of a subject was tracked by recording depth values obtained at user selected points on the subject, with each point representing one pixel on the depth image. As a patient breathes, specific anatomical points on the chest/abdomen will move slightly within the depth image across pixels. By tracking how depth values change for a specific pixel, instead of how the anatomical point moves throughout the image, a respiratory trace can be obtained based on changing depth values of the selected pixel. Tracking these values was implemented via marker-less setup. Varian's RPM system and the Anzai belt system were used in tandem with the Kinect to compare respiratory traces obtained by each using two different subjects. Analysis of the depth information from the Kinect for purposes of phase- and amplitude-based binning correlated well with the RPM and Anzai systems. Interquartile Range (IQR) values were obtained comparing times correlated with specific amplitude and phase percentages against each product. The IQR time spans indicated the Kinect would measure specific percentage values within 0.077 s for Subject 1 and 0.164 s for Subject 2 when compared to values obtained with RPM or Anzai. For 4DCT scans, these times correlate to less than 1 mm of couch movement and would create an offset of 1/2 an acquired slice. By tracking depth values of user selected pixels within the depth image, rather than tracking specific anatomical locations, respiratory motion can be tracked and visualized utilizing the Kinect with results comparable to that of the Varian RPM and Anzai belt. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of

  8. Phylogenetic analysis of anaerobic psychrophilic enrichment cultures obtained from a greenland glacier ice core

    NASA Technical Reports Server (NTRS)

    Sheridan, Peter P.; Miteva, Vanya I.; Brenchley, Jean E.

    2003-01-01

    The examination of microorganisms in glacial ice cores allows the phylogenetic relationships of organisms frozen for thousands of years to be compared with those of current isolates. We developed a method for aseptically sampling a sediment-containing portion of a Greenland ice core that had remained at -9 degrees C for over 100,000 years. Epifluorescence microscopy and flow cytometry results showed that the ice sample contained over 6 x 10(7) cells/ml. Anaerobic enrichment cultures inoculated with melted ice were grown and maintained at -2 degrees C. Genomic DNA extracted from these enrichments was used for the PCR amplification of 16S rRNA genes with bacterial and archaeal primers and the preparation of clone libraries. Approximately 60 bacterial inserts were screened by restriction endonuclease analysis and grouped into 27 unique restriction fragment length polymorphism types, and 24 representative sequences were compared phylogenetically. Diverse sequences representing major phylogenetic groups including alpha, beta, and gamma Proteobacteria as well as relatives of the Thermus, Bacteroides, Eubacterium, and Clostridium groups were found. Sixteen clone sequences were closely related to those from known organisms, with four possibly representing new species. Seven sequences may reflect new genera and were most closely related to sequences obtained only by PCR amplification. One sequence was over 12% distant from its closest relative and may represent a novel order or family. These results show that phylogenetically diverse microorganisms have remained viable within the Greenland ice core for at least 100,000 years.

  9. [Clinical importance of semi-quantitative monitoring of lymphomas using the comparative polymerase chain reaction].

    PubMed

    Slavícková, A; Ivánek, R; Cerný, J; Sálková, J; Trnĕný, M

    2002-11-22

    PCR techniques detecting interchromosomal translocation and clonal immunoglobulin gene rearrangement (IgH) as disease markers in non-Hodgkin's lymphomas (NHL) has been utilised past ten years. However, qualitative PCR detection of persisted minimal residual disease cannot provide clinically useful prognostic information and presently, quantitative approaches are required to predict patient outcome and assess response to the treatment. In some cases, "end-point" quantifying techniques, such as comparative PCR, are applicable and the relative estimation of differences in target quantity may serve in disease monitoring rather than absolute number of target copies. Our method of comparative PCR employs co-amplification of sequences of interest (clonal CDR3, bcl2/Jh) and the segment of Hras 1 gene(ras) as an internal standard. Serial dilutions of stored diagnostic DNAs from blood and bone marrow are examined in the same PCR and, after gel densitometry, the amount of initial target is assessed by comparing exponential products of co-amplification. The comparative PCR assay was utilized in monitoring of NHL patients cured either with conventional therapy, or with high-dose regimens and transplantation with stem cells, or with chimaeric anti-CD20 monoclonal antibody (Rituximab). Results from 50 monitored intervals obtained during several months up to several years were supplemented with clinical statements retrospectively. Some of patients became PCR-negative, reappearance of PCR-positivity was observed as well. The decrease or increase of disease marker corresponded to clinical observations. Results obtained from bone marrow were in agreement with those obtained from blood. End-point quantifying PCR comparative assay may provide an information on the increased risk of relapse and impact of the therapy. The predictive value of these methods depends on the frequency of sample taking and on the sensitivity of the method, which should be monitored in negative cases.

  10. Portal Vein Embolization before Right Hepatectomy: Improved Results Using n-Butyl-Cyanoacrylate Compared to Microparticles Plus Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr; Bize, Pierre; Gunthern, Daniel

    Background: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. Methods: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14).more » PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. Results: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 {+-} 69 % and +23 {+-} 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 {+-} 43 ml and 162 {+-} 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. Conclusion: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.« less

  11. Assessment of the bifidogenic effect of substituted xylo-oligosaccharides obtained from corn straw.

    PubMed

    Moniz, Patrícia; Ho, Ai Ling; Duarte, Luís C; Kolida, Sofia; Rastall, Robert A; Pereira, Helena; Carvalheiro, Florbela

    2016-01-20

    This work evaluates the bifidogenic potential of substituted xylo-oligosaccharides (XOS) obtained from a lignocellulosic feedstock (corn straw). Autohydrolysis was used to selectively hydrolyse the xylan-rich hemicellulosic fraction and the soluble oligosaccharides were purified by gel filtration chromatography. Selected oligosaccharides fractions within the target ranges of polymerization degree (4-6 and 9-21, samples S1 and S2, respectively) were characterized and their bifidogenic potential was investigated by in vitro fermentations using human fecal inocula. Bacterial growth was assessed by fluorescent in situ hybridization (FISH). XOS consumption and short-chain fatty acids (SCFA) production were evaluated and compared with commercial oligosaccharides. Under the tested conditions, all the substrates were utilized by the microbiota, and fermentation resulted in increased bifidobacteria populations. Samples S1 and S2 increased bifidobacteria populations and the production profile of SCFA was similar for XOS samples and commercial oligosaccharides although XOS samples displayed the highest concentration of SCFA on longer fermentation times. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Comparing the Incidence of Febrile Neutropenia Resulting in Hospital Admission Between the Branded Docetaxel and the Generic Formulations.

    PubMed

    Faqeer, Nour Al; Mashni, Ola; Dawoud, Rawan; Rumman, Asma; Hanoun, Esraa; Nazer, Lama

    2017-02-01

    Studies have raised concern about the safety of generic compared with branded drugs. Febrile neutropenia (FN) resulting in hospital admission was compared between the branded docetaxel (Taxotere®, Sanofi) and 2 generic formulations (docetaxel Ebewe and docetaxel Hospira) in patients with breast cancer. This was a retrospective study that included patients with breast cancer who received docetaxel between January 2012 and December 2014. Patients who had an admission diagnosis of FN and had received docetaxel within 14 days prior to admission were evaluated. The docetaxel brand and dose, patient characteristics, hospital length of stay, admission to the intensive care unit (ICU), and mortality were recorded. During the study period, 2904 cycles of docetaxel were given for 876 patients (1519 cycles of docetaxel Sanofi, 811 cycles of docetaxel Hospira, and 574 cycles of docetaxel Ebewe). Among the cycles given, 130 cycles were associated with FN that required hospital admission. The overall incidence of FN resulting in hospital admission was significantly higher in patients who had received docetaxel Hospira, compared with patients who had received docetaxel Sanofi (47[5.8%] cycles vs 53 [3.5%] cycles, P = .009), but there was no significant difference between docetaxel Ebewe and docetaxel Sanofi (30[5.2%] cycles vs 53 [3.5%] cycles, P = .069). All cases of FN resolved except for 1 patient who died in the ICU after receiving docetaxel Ebewe. There was a significant difference in the incidence of FN between docetaxel Sanofi and docetaxel Hospira, but all cases in both groups resolved completely. © 2016, The American College of Clinical Pharmacology.

  13. SCD1 thermal design and test result analysis

    NASA Technical Reports Server (NTRS)

    Cardoso, Humberto Pontes; Muraoka, Issamu; Mantelli, Marcia Barbosa Henriques; Leite, Rosangela M. G.

    1990-01-01

    The SCD 01 (Satelite de Coleta de Dados 01) is a spin stabilized low Earth orbit satellite dedicated to the collection and distribution of environmental data. It was completely developed at the Brazilian Institute for Space Research (INPE) and is scheduled to be launched in 1992. The SCD 01 passive thermal control design configuration is presented and the thermal analysis results are compared with the temperatures obtained from a Thermal Balance Test. The correlation between the analytical and experimental results is considered very good. Numerical flight simulations show that the thermal control design can keep all the subsystem temperatures within their specified temperature range.

  14. Comparison of BOD results obtained by dilution and manometric methods in sanitary landfill leachates.

    PubMed

    Ceçen, F; Yangin, C

    2000-12-01

    This study examined the determination of BOD in landfill leachates by dilution (D-method) and manometric methods (M-method). The differences in results were discussed based on statistical tests. The effects of sample dilution, seeding, chloride and total Kjeldahl nitrogen (TKN) level were examined. The M-method was found to be more sensitive to increases in chloride and TKN concentrations. However, in the M-method the positive interference of nitrogenous BOD (NBOD) to carbonaceous BOD (CBOD) was more successfully prevented. The BOD rate constant k and the ultimate BOD (BODu) were estimated by non-linear regression. With the M-method these parameters could be more reliably estimated than the D-method. Suggestions were made for BOD analyses in landfill leachates in future studies.

  15. Surveillance cultures of samples obtained from biopsy channels and automated endoscope reprocessors after high-level disinfection of gastrointestinal endoscopes

    PubMed Central

    2012-01-01

    Background The instrument channels of gastrointestinal (GI) endoscopes may be heavily contaminated with bacteria even after high-level disinfection (HLD). The British Society of Gastroenterology guidelines emphasize the benefits of manually brushing endoscope channels and using automated endoscope reprocessors (AERs) for disinfecting endoscopes. In this study, we aimed to assess the effectiveness of decontamination using reprocessors after HLD by comparing the cultured samples obtained from biopsy channels (BCs) of GI endoscopes and the internal surfaces of AERs. Methods We conducted a 5-year prospective study. Every month random consecutive sampling was carried out after a complete reprocessing cycle; 420 rinse and swabs samples were collected from BCs and internal surface of AERs, respectively. Of the 420 rinse samples collected from the BC of the GI endoscopes, 300 were obtained from the BCs of gastroscopes and 120 from BCs of colonoscopes. Samples were collected by flushing the BCs with sterile distilled water, and swabbing the residual water from the AERs after reprocessing. These samples were cultured to detect the presence of aerobic and anaerobic bacteria and mycobacteria. Results The number of culture-positive samples obtained from BCs (13.6%, 57/420) was significantly higher than that obtained from AERs (1.7%, 7/420). In addition, the number of culture-positive samples obtained from the BCs of gastroscopes (10.7%, 32/300) and colonoscopes (20.8%, 25/120) were significantly higher than that obtained from AER reprocess to gastroscopes (2.0%, 6/300) and AER reprocess to colonoscopes (0.8%, 1/120). Conclusions Culturing rinse samples obtained from BCs provides a better indication of the effectiveness of the decontamination of GI endoscopes after HLD than culturing the swab samples obtained from the inner surfaces of AERs as the swab samples only indicate whether the AERs are free from microbial contamination or not. PMID:22943739

  16. Shuttle Upper Atmosphere Mass Spectrometer Experimental Flight Results

    NASA Technical Reports Server (NTRS)

    Blanchard, R. C.; Ozoroski, Thomas A.; Nicholson, John Y.

    1994-01-01

    Calibrated pressure measurements for species with mass-to-charge ratios up to 50 amu/e(-) were obtained trom the shuttle upper atmosphere mass spectrometer experiment during re-entry on the STS-35 mission. The principal experimental objective is to obtain measurements of freestream density in the hypersonic rarefied flow flight regime. Data were collected from 180 to about 87 km. However, data above 115 km were contaminated from a source of gas emanating from pressure transdueers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data are compared to the mass spectrometer total pressure with excellent agreement. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions. The freestream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. Standard Atmosphere model, exhibits the wavelike nature seen on previous flights using accelerometry. Selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump.

  17. Per-oral endoscopic myotomy for achalasia. Are results comparable to laparoscopic Heller myotomy?

    PubMed

    Kumagai, Koshi; Tsai, Jon A; Thorell, Anders; Lundell, Lars; Håkanson, Bengt

    2015-05-01

    Per-oral endoscopic myotomy (POEM) has recently been introduced as a minimal invasive alternative to conventional treatment for achalasia. This study aimed to clarify the feasibility and the short-term clinical efficacy of POEM as compared to laparoscopic Heller myotomy (LHM). Treatment outcomes were prospectively recorded and compared between the procedures in a nonrandomized fashion. Reduction rate (RR) in timed barium esophagogram (TBE) was calculated at 1, 2 and 5 min after barium ingestion as: RR = 1- postoperative barium height/preoperative barium height. Risk factors for treatment failure defined as the proportion of patients with RR <0.5 (1 min) and gastroesophageal reflux (GER) after POEM were analyzed. Forty-two consecutive patients who underwent POEM were compared to 41 patients who had a LHM during the immediate time period prior to the introduction of POEM. Ninety percent of the cases reported complete symptom relief after POEM. The percentage of esophageal emptying and RR in TBE improved dramatically by both procedures without significant difference. A longer operation time (odds ratio [OR] 32.80, 95%CI 2.99-359.82, p = 0.004) and younger age (OR 26.81, 95%CI 2.09-344.03, p = 0.012) were the independent predictors of treatment failure after POEM. GER was observed in seven patients where previous dilatation (OR 8.59, 95%CI 1.16-63.45, p = 0.035) and higher body mass index (OR 8.69, 95%CI 1.13-66.63, p = 0.037) were the independent predictors for symptomatic GER after POEM. POEM seems to be a safe and effective treatment option for achalasia in the short-term perspective; an effect well comparable to LHM.

  18. More Ways to Obtain Publications | NREL

    Science.gov Websites

    More Ways to Obtain Publications More Ways to Obtain Publications Through the NREL Library or one information products. The NREL Library The library is open M-F, 8:00 a.m 5:00 p.m. Email or call 303-275-4215 Loan Service. Our OCLC symbol is SOE. Search the NREL Library The NREL Library has extensive resources

  19. Similar fecal immunochemical test results in screening and referral colorectal cancer

    PubMed Central

    van Turenhout, Sietze T; van Rossum, Leo GM; Oort, Frank A; Laheij, Robert JF; van Rijn, Anne F; Terhaar sive Droste, Jochim S; Fockens, Paul; van der Hulst, René WM; Bouman, Anneke A; Jansen, Jan BMJ; Meijer, Gerrit A; Dekker, Evelien; Mulder, Chris JJ

    2012-01-01

    AIM: To improve the interpretation of fecal immunochemical test (FIT) results in colorectal cancer (CRC) cases from screening and referral cohorts. METHODS: In this comparative observational study, two prospective cohorts of CRC cases were compared. The first cohort was obtained from 10 322 average risk subjects invited for CRC screening with FIT, of which, only subjects with a positive FIT were referred for colonoscopy. The second cohort was obtained from 3637 subjects scheduled for elective colonoscopy with a positive FIT result. The same FIT and positivity threshold (OC sensor; ≥ 50 ng/mL) was used in both cohorts. Colonoscopy was performed in all referral subjects and in FIT positive screening subjects. All CRC cases were selected from both cohorts. Outcome measurements were mean FIT results and FIT scores per tissue tumor stage (T stage). RESULTS: One hundred and eighteen patients with CRC were included in the present study: 28 cases obtained from the screening cohort (64% male; mean age 65 years, SD 6.5) and 90 cases obtained from the referral cohort (58% male; mean age 69 years, SD 9.8). The mean FIT results found were higher in the referral cohort (829 ± 302 ng/mL vs 613 ± 368 ng/mL, P = 0.02). Tissue tumor stage (T stage) distribution was different between both populations [screening population: 13 (46%) T1, eight (29%) T2, six (21%) T3, one (4%) T4 carcinoma; referral population: 12 (13%) T1, 22 (24%) T2, 52 (58%) T3, four (4%) T4 carcinoma], and higher T stage was significantly associated with higher FIT results (P < 0.001). Per tumor stage, no significant difference in mean FIT results was observed (screening vs referral: T1 498 ± 382 ng/mL vs 725 ± 374 ng/mL, P = 0.22; T2 787 ± 303 ng/mL vs 794 ± 341 ng/mL, P = 0.79; T3 563 ± 368 ng/mL vs 870 ± 258 ng/mL, P = 0.13; T4 not available). After correction for T stage in logistic regression analysis, no significant differences in mean FIT results were observed between both types of cohorts (P = 0

  20. Analysis of the first laser echoes obtained on the reflector of Luna 21

    NASA Technical Reports Server (NTRS)

    Abalakin, V. K.; Calame, O.; Orszag, A.; Kokurin, Iu. L.; Mulholland, J. D.; Silverberg, E. C.

    1973-01-01

    The international program of lunar telemetry, which has been in operation for three and one-half years, is intended to supply basic information for study of the lunar motion and the internal physics of the moon and the earth, particularly with reference to movement of the pole and displacements of plates. Laser echoes were obtained on Jan. 23, 1973 from the French reflector placed on the moon by Luna 21. Two series of firings, made with a 3-J laser radiated by the 2.7-m telescope of the McDonald Observatory (Texas) made it possible to identify significant echoes of an intensity comparable to those obtained with the reflector set down by Apollo 15. The path time measurements are compatible with normal coordinates.

  1. Mobile Versus Fixed Facility: Latinas' Attitudes and Preferences for Obtaining a Mammogram.

    PubMed

    Scheel, John R; Tillack, Allison A; Mercer, Lauren; Coronado, Gloria D; Beresford, Shirley A A; Molina, Yamile; Thompson, Beti

    2018-01-01

    Mobile mammographic services have been proposed as a way to reduce Latinas' disproportionate late-stage presentation compared with white women by increasing their access to mammography. The aims of this study were to assess why Latinas may not use mobile mammographic services and to explore their preferences after using these services. Using a mixed-methods approach, a secondary analysis was conducted of baseline survey data (n = 538) from a randomized controlled trial to improve screening mammography rates among Latinas in Washington. Descriptive statistics and bivariate regression were used to characterize mammography location preferences and to test for associations with sociodemographic indices, health care access, and perceived breast cancer risk and beliefs. On the basis of these findings, a qualitative study (n = 18) was used to explore changes in perceptions after using mobile mammographic services. More Latinas preferred obtaining a mammogram at a fixed facility (52.3% [n = 276]) compared with having no preference (46.3% [n = 249]) and preferring mobile mammographic services (1.7% [n = 9]). Concerns about privacy and comfort (15.6% [n = 84]) and about general quality (10.6% [n = 57]) were common reasons for preferring a fixed facility. Those with no history of mammography preferred a fixed facility (P < .05). In the qualitative study, Latinas expressed similar initial concerns but became positive toward the mobile mammographic services after obtaining a mammogram. Although most Latinas preferred obtaining a mammogram at a fixed facility, positive experiences with mobile mammography services changed their attitudes toward them. These findings highlight the need to include community education when using mobile mammographic service to increase screening mammography rates in underserved communities. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. A Comparative Study of Performance in the Conners' Continuous Performance Test between Brazilian and North American Children

    ERIC Educational Resources Information Center

    Miranda, Monica Carolina; Sinnes, Elaine Girao; Pompeia, Sabine; Bueno, Orlando Francisco Amodeo

    2008-01-01

    Objective: The present study investigated the performance of Brazilian children in the Continuous Performance Test, CPT-II, and compared results to those of the norms obtained in the United States. Method: The U.S. norms were compared to those of a Brazilian sample composed of 6- to 11-year-olds separated into 4 age-groups (half boys) that…

  3. Short-Term Audiological Results of Diode Laser in Comparison with Manual Perforation in Stapes Surgery

    PubMed Central

    Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do

    2018-01-01

    Introduction  Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective  To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method  Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results  Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion  Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser. PMID:29619098

  4. Short-Term Audiological Results of Diode Laser in Comparison with Manual Perforation in Stapes Surgery.

    PubMed

    Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do

    2018-04-01

    Introduction  Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective  To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method  Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results  Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion  Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser.

  5. Genotoxicity of corrosion eluates obtained from endosseous implants.

    PubMed

    Ribeiro, Daniel Araki; Matsumoto, Mariza Akemi; Padovan, Luís Eduardo Marques; Marques, Mariângela Esther Alencar; Salvadori, Daisy Maria Fávero

    2007-03-01

    Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions. The materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C. None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used. The results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.

  6. A Simulation Study Comparing Procedures for Assessing Individual Educational Growth. Report No. 182.

    ERIC Educational Resources Information Center

    Richards, James M., Jr.

    A computer simulation procedure was developed to reproduce the overall pattern of results obtained in the Educational Testing Service Growth Study. Then simulated data for seven sets of 10,000 to 15,000 cases were analyzed, and findings compared on the basis of correlations between estimated and true growth scores. Findings showed that growth was…

  7. Interactions of cisplatin analogues with lysozyme: a comparative analysis.

    PubMed

    Ferraro, Giarita; De Benedictis, Ilaria; Malfitano, Annamaria; Morelli, Giancarlo; Novellino, Ettore; Marasco, Daniela

    2017-10-01

    The biophysical characterization of drug binding to proteins plays a key role in structural biology and in the discovery and optimization of drug discovery processes. The search for optimal combinations of biophysical techniques that can correctly and efficiently identify and quantify binding of metal-based drugs to their final target is challenging, due to the physicochemical properties of these agents. Different cisplatin derivatives have shown different citotoxicities in most common cancer lines, suggesting that they exert their biological activity via different mechanisms of action. Here we carried out a comparative analysis, by studying the behaviours of three Pt-compounds under the same experimental conditions and binding assays to properly deepen the determinants of the different MAOs. Indeed we compared the results obtained using surface plasmon resonance, isothermal titration calorimetry, fluorescence spectroscopy and thermal shift assays based on circular dichroism experiments in the characterization of the formation of adducts obtained upon reaction of cisplatin, carboplatin and iodinated analogue of cisplatin, cis-Pt (NH 3 ) 2 I 2 , with the model protein hen egg white lysozyme, both at neutral and acid pHs. Further we reasoned on the applicability of employed techniques for the study the thermodynamics and kinetics of the reaction of a metallodrug with a protein and to reveal which information can be obtained using a combination of these analyses. Data were discussed on the light of the existing structural data collected on the platinated protein.

  8. A Modeling Approach to Enhance Animal-Obtained Oceanographic Data Geo- Position

    NASA Astrophysics Data System (ADS)

    Tremblay, Y.; Robinson, P.; Weise, M. J.; Costa, D. P.

    2006-12-01

    Diving animals are increasingly being used as platforms to collect oceanographic data such as CTD profiles. Animal borne sensors provide an amazing amount of data that have to be spatially referenced. Because of technical limitations geo-position of these data mostly comes from the interpolation of locations obtained through the ARGOS positioning system. This system lacks spatio-temporal resolution compared to the Global Positioning System (GPS) and therefore, the positions of these oceanographic data are not well defined. A consequence of this is that many data collected in coastal regions are discarded, because many casts' records fell on land. Using modeling techniques, we propose a method to deal with this problem. The method is rather intuitive, and instead of deleting unreasonable or low-quality locations, it uses them by taking into account their lack of precision as a source of information. In a similar way, coastlines are used as sources of information, because marine animals do not travel over land. The method was evaluated using simultaneously obtained tracks with the Argos and GPS system. The tracks obtained from this method are considerably enhanced and allow a more accurate geo-reference of oceanographic data. In addition, the method provides a way to evaluate spatial errors for each cast that is not otherwise possible with classical filtering methods.

  9. Why to compare absolute numbers of mitochondria.

    PubMed

    Schmitt, Sabine; Schulz, Sabine; Schropp, Eva-Maria; Eberhagen, Carola; Simmons, Alisha; Beisker, Wolfgang; Aichler, Michaela; Zischka, Hans

    2014-11-01

    Prompted by pronounced structural differences between rat liver and rat hepatocellular carcinoma mitochondria, we suspected these mitochondrial populations to differ massively in their molecular composition. Aiming to reveal these mitochondrial differences, we came across the issue on how to normalize such comparisons and decided to focus on the absolute number of mitochondria. To this end, fluorescently stained mitochondria were quantified by flow cytometry. For rat liver mitochondria, this approach resulted in mitochondrial protein contents comparable to earlier reports using alternative methods. We determined similar protein contents for rat liver, heart and kidney mitochondria. In contrast, however, lower protein contents were determined for rat brain mitochondria and for mitochondria from the rat hepatocellular carcinoma cell line McA 7777. This result challenges mitochondrial comparisons that rely on equal protein amounts as a typical normalization method. Exemplarily, we therefore compared the activity and susceptibility toward inhibition of complex II of rat liver and hepatocellular carcinoma mitochondria and obtained significant discrepancies by either normalizing to protein amount or to absolute mitochondrial number. Importantly, the latter normalization, in contrast to the former, demonstrated a lower complex II activity and higher susceptibility toward inhibition in hepatocellular carcinoma mitochondria compared to liver mitochondria. These findings demonstrate that solely normalizing to protein amount may obscure essential molecular differences between mitochondrial populations. Copyright © 2014 Elsevier B.V. and Mitochondria Research Society. All rights reserved.

  10. Contrast matching of line gratings obtained with NXE3XXX and EUV- interference lithography

    NASA Astrophysics Data System (ADS)

    Tasdemir, Zuhal; Mochi, Iacopo; Olvera, Karen Garrido; Meeuwissen, Marieke; Yildirim, Oktay; Custers, Rolf; Hoefnagels, Rik; Rispens, Gijsbert; Fallica, Roberto; Vockenhuber, Michaela; Ekinci, Yasin

    2017-10-01

    Extreme UV lithography (EUVL) has gained considerable attention for several decades as a potential technology for the semiconductor industry and it is now close to being adopted in high-volume manufacturing. At Paul Scherrer Institute (PSI), we have focused our attention on EUV resist performance issues by testing available high-performance EUV resists in the framework of a joint collaboration with ASML. For this purpose, we use the grating-based EUV-IL setup installed at the Swiss Light Source (SLS) at PSI, in which a coherent beam with 13.5 nm wavelength is used to produce a periodic aerial image with virtually 100% contrast and large depth of focus. Interference lithography is a relatively simple technique and it does not require many optical components, therefore the unintended flare is minimized and the aerial image is well-defined sinusoidal pattern. For the collaborative work between PSI and ASML, exposures are being performed on the EUV-IL exposure tool at PSI. For better quantitative comparison to the NXE scanner results, it is targeted to determine the actual NILS of the EUV-IL exposure tool at PSI. Ultimately, any resist-related metrology must be aligned and compared with the performance of EUV scanners. Moreover, EUV-IL is a powerful method for evaluating the resist performance and a resist which performs well with EUV-IL, shows, in general, also good performance with NXE scanners. However, a quantitative prediction of the performance based on EUV-IL measurements has not been possible due to the differences in aerial image formation. In this work, we aim to study the performance of EUV resists with different aerial images. For this purpose, after the real interference pattern exposure, we overlay a flat field exposure to emulate different levels of contrast. Finally, the results are compared with data obtained from EUV scanner. This study will enable not only match the data obtained from EUV- IL at PSI with the performance of NXE scanners, but also a

  11. Results of Physical Property Measurements Obtained during the CHIKYU Cruise CK16-01 to Hydrothermal Fields of the Middle Okinawa Trough

    NASA Astrophysics Data System (ADS)

    Tanikawa, W.; Masaki, Y.; Komori, S.; Torimoto, J.; Makio, M.; Ohta, Y.; Nozaki, T.; Ishibashi, J. I.; Kumagai, H.; Maeda, L.; Hamada, Y.

    2016-12-01

    The middle Okinawa trough, along the Ryukyu-arc on the margin of the western Pacific, fosters several hydrothermal fields. The cruise CK16-01 of D/V CHIKYU targeted the Iheya-North Field and Noho hydrothermal site. More than ten-days extensive coring was carried out with Logging While Drilling (LWD) and deployment of Kuroko cultivation apparatus between February 29th to March 17th2016. Here we present the results of the physical property measurements obtained using Chikyu's on-board laboratory. Cores were sampled among three sites where the seafloor environments were quite different: the Noho site (C9017), a site between the Natsu and Aki sites of the Iheya-North field (C9021), and the Iheya-North Aki site (C9023). Site C9017 was near the center of the hydrothermal activity, and the obtained core was limited 36 m in length and 30 % in the recovery rate. At 70 mbsf (meters below seafloor), the grain density and bulk density of the sediment reached their maxim (3.7 g/m3 and 2.7 g/cm3, respectively), while thermal conductivity reached its lowest value (0.6 W/m·K). Site C9021 yielded a 54 m core, with a core recovery rate of 50 %. Coarse pumiceous layers were found at 68 mbsf, with a hydrothermally altered layer appearing below 68 mbsf. The mean grain density value was 2.4 g/cm3 and was uniform throughout the core. The mean bulk density value of the pumiceous layers was 1.3 g/cm3, and of the hydrothermally altered layer was 2.1 g/cm3. Site C9023 was close to the active hydrothermal chimneys of the Iheya-North Aki site, and yielded 33 m of core with a core recovery rate of 16 %. Massive sulfide layers were found below 48 mbsf with grain density and bulk density values varying between 2.8-4.7 g/cm3 and 1.5-3.9 g/cm3, respectively. Magnetic susceptibility exhibited a high anomaly in a sedimented anhydrite layer found between 95 and 135 mbsf, and a high porosity and low resistivity zone was found below 150 mbsf. Together, these data from drilling cores and onboard

  12. Recent Results With Coupled Opto-Electronic Oscillators

    NASA Astrophysics Data System (ADS)

    Yao, X. S.; Maleki, L.; Wu, C.; Davis, L.; Forouhar, S.

    1998-07-01

    We present experimental results of coupled opto-electronic oscillators (COEOs) constructed with a semiconductor optical-amplifier-based ring laser, a semiconductor Fabry-Perot laser, and a semiconductor colliding-pulse mode-locked laser. Each COEO can simultaneously generate short optical pulses and spectrally pure RF signals. With these devices, we obtained optical pulses as short as 6 ps and RF signals as high in frequency as 18 GHz with a spectral purity comparable to an HP 8561B synthesizer. These experiments demonstrate that COEOs are promising compact sources for generating low jitter optical pulses and low phase noise RF/millimeter wave signals.

  13. Cryptic species revealed by molecular phylogenetic analysis of sequences obtained from basidiomata of Tulasnella.

    PubMed

    Cruz, Darío; Suárez, Juan Pablo; Kottke, Ingrid; Piepenbring, Meike

    2014-01-01

    Delimitation of species and the search for a proper threshold for defining phylogenetic species in fungi are under discussion. In this study, morphological and molecular data are correlated to delimit species of Tulasnella, the most important mycobionts of Orchidaceae, which suffer from poor taxonomy. Resupinate basidiomata of Tulasnella species were collected in Ecuador and Germany, and 11 specimens (seven from Ecuador, four from Germany) were assigned to traditional species concepts by use of morphological keys. The specimens were compared by micro-anatomical examination with 75 specimens of Tulasnella borrowed from fungaria to obtain better insights on variation of characters. Sequences of the ITS region (127) were obtained after cloning from the fresh basidiomata and from pure cultures. Proportional variability of ITS sequences was analyzed within and among the cultures and the specimens designated to different morphospecies. Results suggested an intragenomic variation of less than 2%, an intraspecific variation of up to 4% and an interspecific divergence of more than 9% in Tulasnella. Cryptic species in Tulasnella, mostly from Ecuador, were revealed by phylogenetic analyses with 4% intraspecific divergence as a minimum threshold for delimiting species. Conventional diagnostic morphological characters appeared insufficient for species characterization. Arguments are presented for molecular delimitation of the established species Tulasnella albida, T. asymmetrica, T. eichleriana, T. cf. pinicola, T. tomaculum and T. violea. © 2014 by The Mycological Society of America.

  14. Off-set stabilizer for comparator output

    DOEpatents

    Lunsford, James S.

    1991-01-01

    A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.

  15. On-line sulfur isotope analysis of organic material by direct combustion: Preliminary results and potential applications

    USGS Publications Warehouse

    Kester, C.L.; Rye, R.O.; Johnson, C.A.; Schwartz, C.H.; Holmes, C.H.

    2001-01-01

    Sulfur isotopes have received little attention in ecology studies because plant and animal materials typically have low sulfur concentrations (< 1 wt.%) necessitating labor-intensive chemical extraction prior to analysis. To address the potential of direct combustion of organic material in an elemental analyzer coupled with a mass spectrometer, we compared results obtained by direct combustion to results obtained by sulfur extraction with Eschka's mixture. Direct combustion of peat and animal tissue gave reproducibility of better than 0.5??? and on average, values are 0.8??? higher than values obtained by Eschka extraction. Successful direct combustion of organic material appears to be a function of sample matrix and sulfur concentration. Initial results indicate that direct combustion provides fast, reliable results with minimal preparation. Pilot studies underway include defining bear diets and examining fluctuations between freshwater and brackish water in coastal environments.

  16. Comparing a Fischer-Tropsch Alternate Fuel to JP-8 and Their 50-50 Blend: Flow and Flame Visualization Results

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Tacina, M.

    2013-01-01

    Combustion performance of a Fischer-Tropsch (FT) jet fuel manufactured by Sasol was compared to JP-8 and a 50-50 blend of the two fuels, using the NASA/Woodward 9 point Lean Direct Injector (LDI) in its baseline configuration. The baseline LDI configuration uses 60deg axial air-swirlers, whose vanes generate clockwise swirl, in the streamwise sense. For all cases, the fuel-air equivalence ratio was 0.455, and the combustor inlet pressure and pressure drop were 10-bar and 4 percent. The three inlet temperatures used were 828, 728, and 617 K. The objectives of this experiment were to visually compare JP-8 flames with FT flames for gross features. Specifically, we sought to ascertain in a simple way visible luminosity, sooting, and primary flame length of the FT compared to a standard JP grade fuel. We used color video imaging and high-speed imaging to achieve these goals. The flame color provided a way to qualitatively compare soot formation. The length of the luminous signal measured using the high speed camera allowed an assessment of primary flame length. It was determined that the shortest flames resulted from the FT fuel.

  17. Quantitative analysis of drainage obtained from aerial photographs and RBV/LANDSAT images

    NASA Technical Reports Server (NTRS)

    Dejesusparada, N. (Principal Investigator); Formaggio, A. R.; Epiphanio, J. C. N.; Filho, M. V.

    1981-01-01

    Data obtained from aerial photographs (1:60,000) and LANDSAT return beam vidicon imagery (1:100,000) concerning drainage density, drainage texture, hydrography density, and the average length of channels were compared. Statistical analysis shows that significant differences exist in data from the two sources. The highly drained area lost more information than the less drained area. In addition, it was observed that the loss of information about the number of rivers was higher than that about the length of the channels.

  18. Suppression tuning of distortion-product otoacoustic emissions: Results from cochlear mechanics simulation

    PubMed Central

    Liu, Yi-Wen; Neely, Stephen T.

    2013-01-01

    This paper presents the results of simulating the acoustic suppression of distortion-product otoacoustic emissions (DPOAEs) from a computer model of cochlear mechanics. A tone suppressor was introduced, causing the DPOAE level to decrease, and the decrement was plotted against an increasing suppressor level. Suppression threshold was estimated from the resulting suppression growth functions (SGFs), and suppression tuning curves (STCs) were obtained by plotting the suppression threshold as a function of suppressor frequency. Results show that the slope of SGFs is generally higher for low-frequency suppressors than high-frequency suppressors, resembling those obtained from normal hearing human ears. By comparing responses of normal (100%) vs reduced (50%) outer-hair-cell sensitivities, the model predicts that the tip-to-tail difference of the STCs correlates well with that of intra-cochlear iso-displacement tuning curves. The correlation is poorer, however, between the sharpness of the STCs and that of the intra-cochlear tuning curves. These results agree qualitatively with what was recently reported from normal-hearing and hearing-impaired human subjects, and examination of intra-cochlear model responses can provide the needed insight regarding the interpretation of DPOAE STCs obtained in individual ears. PMID:23363112

  19. Effect of Clinical and Attitudinal Characteristics on Obtaining Comprehensive Medication Reviews.

    PubMed

    Farris, Karen B; Salgado, Teresa M; Aneese, Nadia; Marshall, Vincent D; Pendergast, Jane F; Frank, Jessica; Chrischilles, Elizabeth A; Doucette, William R

    2016-04-01

    Comprehensive medication reviews (CMRs) consist of in-depth reviews of patients' medications to identify effectiveness or safety problems and often generate cost savings for individuals. Despite their advantages, CMRs are not widely obtained. Previous studies found that older age, female sex, and experience of side effects were associated with obtaining a medication review. To quantify the association between attitudinal and clinical factors with intention and predict future behavior to obtain a CMR among Medicare Part D beneficiaries. A sample of Medicare Part D beneficiaries from 1 health care plan (n = 660) completed a 14-item survey over the telephone assessing factors that were hypothesized to affect their intention and behavior to obtain a CMR. The survey collected medication use history and health care information with the medication user self-evaluation tool, health status, adherence, intention to obtain a CMR, and demographic characteristics. Subjects subsequently were informed that they could obtain a CMR from their pharmacies. Claims data were obtained that indicated which subjects received a CMR. Two dependent variables were predicted: intention to schedule a CMR using a multivariate linear regression model and receipt of a CMR using a logistic regression and including intention as a predictor variable. The mean age of participants was 76.6 (SD = 7.61) years; 71% were female; and participants took an average of 5.2 (SD = 3.18) medications. The intention to have a CMR was 2.85 (SD = 1.41) on a 5-point scale, and 5.6% of the participants actually had a CMR. Worrying about medications doing more harm than good, number of pharmacies where participants obtained their medications from, number of medications, and number of medical conditions predicted intention to obtain a CMR. Patients who perceived their health status to be poorer compared with others their age were more likely to have a CMR. Intention to obtain a CMR was not associated with receipt of a CMR

  20. 5 CFR 1501.12 - Obtaining further information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Obtaining further information. 1501.12 Section 1501.12 Administrative Personnel THE INTERNATIONAL ORGANIZATIONS EMPLOYEES LOYALTY BOARD OPERATIONS OF THE INTERNATIONAL ORGANIZATIONS EMPLOYEES LOYALTY BOARD § 1501.12 Obtaining further information...

  1. Comparison of microcrystalline characterization results from oil palm midrib alpha cellulose using different delignization method

    NASA Astrophysics Data System (ADS)

    Yuliasmi, S.; Pardede, T. R.; Nerdy; Syahputra, H.

    2017-03-01

    Oil palm midrib is one of the waste generated by palm plants containing 34.89% cellulose. Cellulose has the potential to produce microcrystalline cellulose can be used as an excipient in tablet formulations by direct compression. Microcrystalline cellulose is the result of a controlled hydrolysis of alpha cellulose, so the alpha cellulose extraction process of oil palm midrib greatly affect the quality of the resulting microcrystalline cellulose. The purpose of this study was to compare the microcrystalline cellulose produced from alpha cellulose extracted from oil palm midrib by two different methods. Fisrt delignization method uses sodium hydroxide. Second method uses a mixture of nitric acid and sodium nitrite, and continued with sodium hydroxide and sodium sulfite. Microcrystalline cellulose obtained by both method was characterized separately, including organoleptic test, color reagents test, dissolution test, pH test and determination of functional groups by FTIR. The results was compared with microcrystalline cellulose which has been available on the market. The characterization results showed that microcrystalline cellulose obtained by first method has the most similar characteristics to the microcrystalline cellulose available in the market.

  2. A comparative study of electrochemical machining process parameters by using GA and Taguchi method

    NASA Astrophysics Data System (ADS)

    Soni, S. K.; Thomas, B.

    2017-11-01

    In electrochemical machining quality of machined surface strongly depend on the selection of optimal parameter settings. This work deals with the application of Taguchi method and genetic algorithm using MATLAB to maximize the metal removal rate and minimize the surface roughness and overcut. In this paper a comparative study is presented for drilling of LM6 AL/B4C composites by comparing the significant impact of numerous machining process parameters such as, electrolyte concentration (g/l),machining voltage (v),frequency (hz) on the response parameters (surface roughness, material removal rate and over cut). Taguchi L27 orthogonal array was chosen in Minitab 17 software, for the investigation of experimental results and also multiobjective optimization done by genetic algorithm is employed by using MATLAB. After obtaining optimized results from Taguchi method and genetic algorithm, a comparative results are presented.

  3. Comparison of the electromagnetic responses of C 12 obtained from the Green's function Monte Carlo and spectral function approaches

    DOE PAGES

    Rocco, Noemi; Lovato, Alessandro; Benhar, Omar

    2016-12-23

    Here, the electromagnetic responses of carbon obtained from the Green's function Monte Carlo and spectral function approaches using the same dynamical input are compared in the kinematical region corresponding to momentum transfer in the range 300–570 MeV. The results of our analysis, aimed at pinning down the limits of applicability of the approximations involved in the two schemes, indicate that the factorization ansatz underlying the spectral function formalism provides remarkably accurate results down to momentum transfer as low as 300 MeV. On the other hand, it appears that at 570 MeV relativistic corrections to the electromagnetic current not included inmore » the Monte Carlo calculations may play a significant role in the transverse channel.« less

  4. Comparison of the electromagnetic responses of C 12 obtained from the Green's function Monte Carlo and spectral function approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocco, Noemi; Lovato, Alessandro; Benhar, Omar

    Here, the electromagnetic responses of carbon obtained from the Green's function Monte Carlo and spectral function approaches using the same dynamical input are compared in the kinematical region corresponding to momentum transfer in the range 300–570 MeV. The results of our analysis, aimed at pinning down the limits of applicability of the approximations involved in the two schemes, indicate that the factorization ansatz underlying the spectral function formalism provides remarkably accurate results down to momentum transfer as low as 300 MeV. On the other hand, it appears that at 570 MeV relativistic corrections to the electromagnetic current not included inmore » the Monte Carlo calculations may play a significant role in the transverse channel.« less

  5. On the Search for Retrotransposons: Alternative Protocols to Obtain Sequences to Learn Profile Hidden Markov Models.

    PubMed

    Fischer, Carlos N; Campos, Victor De A; Barella, Victor H

    2018-05-01

    Profile hidden Markov models (pHMMs) have been used to search for transposable elements (TEs) in genomes. For the learning of pHMMs aimed to search for TEs of the retrotransposon class, the conventional protocol is to use the whole internal nucleotide portions of these elements as representative sequences. To further explore the potential of pHMMs in such a search, we propose five alternative ways to obtain the sets of representative sequences of TEs other than the conventional protocol. In this study, we are interested in Bel-PAO, Copia, Gypsy, and DIRS superfamilies from the retrotransposon class. We compared the pHMMs of all six protocols. The test results show that, for each TE superfamily, the pHMMs of at least two of the proposed protocols performed better than the conventional one and that the number of correct predictions provided by the latter can be improved by considering together the results of one or more of the alternative protocols.

  6. 2D biological representations with reduced speckle obtained from two perpendicular ultrasonic arrays.

    PubMed

    Rodriguez-Hernandez, Miguel A; Gomez-Sacristan, Angel; Sempere-Payá, Víctor M

    2016-04-29

    Ultrasound diagnosis is a widely used medical tool. Among the various ultrasound techniques, ultrasonic imaging is particularly relevant. This paper presents an improvement to a two-dimensional (2D) ultrasonic system using measurements taken from perpendicular planes, where digital signal processing techniques are used to combine one-dimensional (1D) A-scans were acquired by individual transducers in arrays located in perpendicular planes. An algorithm used to combine measurements is improved based on the wavelet transform, which includes a denoising step during the 2D representation generation process. The inclusion of this new denoising stage generates higher quality 2D representations with a reduced level of speckling. The paper includes different 2D representations obtained from noisy A-scans and compares the improvements obtained by including the denoising stage.

  7. The Data Evaluation for Obtaining Accuracy and Reliability

    NASA Astrophysics Data System (ADS)

    Kim, Chang Geun; Chae, Kyun Shik; Lee, Sang Tae; Bhang, Gun Woong

    2012-11-01

    Nemours scientific measurement results are flooded from the paper, data book, etc. as fast growing of internet. We meet many different measurement results on the same measurand. In this moment, we are face to choose most reliable one out of them. But it is not easy to choose and use the accurate and reliable data as we do at an ice cream parlor. Even expert users feel difficult to distinguish the accurate and reliable scientific data from huge amount of measurement results. For this reason, the data evaluation is getting more important as the fast growing of internet and globalization. Furthermore the expressions of measurement results are not in standardi-zation. As these need, the international movement has been enhanced. At the first step, the global harmonization of terminology used in metrology and the expression of uncertainty in measurement were published in ISO. These methods are wide spread to many area of science on their measurement to obtain the accuracy and reliability. In this paper, it is introduced that the GUM, SRD and data evaluation on atomic collisions.

  8. Detection of quinolones in commercial eggs obtained from farms in the Espaíllat Province in the Dominican Republic.

    PubMed

    Moscoso, S; de los Santos, F Solís; Andino, A G; Diaz-Sanchez, Sandra; Hanning, I

    2015-01-01

    Previously, we reported the use of quinolones in broiler chickens resulted in residues in retail poultry meat obtained from nine districts in the Santiago Province of the Dominican Republic. Residues in poultry products are a concern due to consumer allergies and the potential to develop antibiotic-resistant bacteria. Given the use of quinolones in poultry production and our previous findings in poultry meat, the objective of this study was to evaluate the presence of quinolone residues in eggs. Samples were collected from 48 different farms located in three of the four municipalities (Moca, Cayetano Germosén, and Jamao) of the Espaíllat Province. Each farm was sampled three times between July and September for a total of 144 samples. Samples were evaluated qualitatively and quantitatively for quinolone residues using the Equinox test. Operation systems (cage or floor), seasonality, and location were considered along with egg-producer sizes that were defined as small scale, <30,000 eggs per day; medium scale, 30,000 to 60,000 eggs per day; or large scale, >60,000 eggs per day. From small-, medium-, and large-scale producers, 69, 50, and 40% of samples were positive for quinolone residues, respectively. A greater number of samples were positive (61%) in floor-laying hen producers compared with those using cages (40%). In the Jamao municipality, 67% of the samples were positive compared with Moca and Cayetano Germosén, where 56 and 25% of samples were positive, respectively. Sampling time had an effect on percent positives: samples collected in July, August, and September were 71, 19, and 63% positive, respectively. Overall, 51% of the samples obtained from eggs produced in the province of Espaíllat were positive for quinolone residues at levels higher than the maximum limits for edible tissue established by the regulatory agencies, including the European Union and U.S. Department of Agriculture. The results obtained from this research confirmed the presence of

  9. 48 CFR 9.105-1 - Obtaining information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Obtaining information. 9... information. (a) Before making a determination of responsibility, the contracting officer shall possess or obtain information sufficient to be satisfied that a prospective contractor currently meets the...

  10. Concordance of macular pigment measurements obtained using customized heterochromatic flicker photometry, dual-wavelength autofluorescence, and single-wavelength reflectance.

    PubMed

    Dennison, Jessica L; Stack, Jim; Beatty, Stephen; Nolan, John M

    2013-11-01

    This study compares in vivo measurements of macular pigment (MP) obtained using customized heterochromatic flicker photometry (cHFP; Macular Metrics Densitometer(™)), dual-wavelength fundus autofluorescence (Heidelberg Spectralis(®) HRA + OCT MultiColor) and single-wavelength fundus reflectance (Zeiss Visucam(®) 200). MP was measured in one eye of 62 subjects on each device. Data from 49 subjects (79%) was suitable for analysis. Agreement between the Densitometer and Spectralis was investigated at various eccentricities using a variety of quantitative and graphical methods, including: Pearson correlation coefficient to measure degree of scatter (precision), accuracy coefficient, concordance correlation coefficient (ccc), paired t-test, scatter and Bland-Altman plots. The relationship between max MP from the Visucam and central MP from the Spectralis and Densitometer was investigated using regression methods. Agreement was strong between the Densitometer and Spectralis at all central eccentricities (e.g. at 0.25° eccentricity: accuracy = 0.97, precision = 0.90, ccc = 0.87). Regression analysis showed a very weak relationship between the Visucam and Densitometer (e.g. Visucam max on Densitometer central MP: R(2) = 0.008, p = 0.843). Regression analysis also demonstrated a weak relationship between MP measured by the Spectralis and Visucam (e.g. Visucam max on Spectralis central MP: R(2) = 0.047, p = 0.348). MP values obtained using the Heidelberg Spectralis are comparable to MP values obtained using the Densitometer. In contrast, MP values obtained using the Zeiss Visucam are not comparable with either the Densitometer or the Spectralis MP measuring devices. Taking cHFP as the current standard to which other MP measuring devices should be compared, the Spectralis is suitable for use in a clinical and research setting, whereas the Visucam is not. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Impact of process parameters in the generation of novel aspirin nanoemulsions--comparative studies between ultrasound cavitation and microfluidizer.

    PubMed

    Tang, Siah Ying; Shridharan, Parthasarathy; Sivakumar, Manickam

    2013-01-01

    In the present investigation, the operating efficiency of a bench-top air-driven microfluidizer has been compared to that of a bench-top high power ultrasound horn in the production of pharmaceutical grade nanoemulsions using aspirin as a model drug. The influence of important process variables as well as the pre-homogenization and drug loading on the resultant mean droplet diameter and size distribution of emulsion droplets was studied in an oil-in-water nanoemulsion incorporated with a model drug aspirin. Results obtained show that both the emulsification methods were capable of producing very fine nanoemulsions containing aspirin with the minimum droplet size ranging from 150 to 170 nm. In case of using the microfluidizer, it has been observed that the size of the emulsion droplets obtained was almost independent of the applied microfluidization pressure (200-600 bar) and the number of passes (up to 10 passes) while the pre-homogenization and drug loading had a marginal effect in increasing the droplet size. Whereas, in the case of ultrasound emulsification, the droplet size was generally decreased with an increase in sonication amplitude (50-70%) and period of sonication but the resultant emulsion was found to be dependent on the pre-homogenization and drug loading. The STEM microscopic observations illustrated that the optimized formulations obtained using ultrasound cavitation technique are comparable to microfluidized emulsions. These comparative results demonstrated that ultrasound cavitation is a relatively energy-efficient yet promising method of pharmaceutical nanoemulsions as compared to microfluidizer although the means used to generate the nanoemulsions are different. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. A comparative study of results of the von Langenbeck and the V-Y pushback palatoplasties.

    PubMed

    Krause, C J; Tharp, R F; Morris, H L

    1976-01-01

    The incidence of velopharyngeal competence noted in 267 cleft palate patients following palatoplsty has been reviewed. Comparisons have been drawn with regard to the cleft type and the surgical technique performed. Since there were relatively small numbers of subjects in some categories, differences in age at last examination between the von Langenbeck and V-Y palatoplasty groups, some patients were very young at time of evaluation, and a number of different surgeons at different levels of training and experience performed the surgery, the differences in velopharyngeal competence found should be viewed as trends and this report as preliminary. In general, there was a trend toward smaller percentages of patients attaining acceptable velopharyngeal competence as the severity of the cleft increased. Of those with clefts of the soft palate only 86 per cent achieved competence. Among those patients with clefts of the palate only, 67 per cent achieved competence, whereas only 57 per cent of those with clefts of the lip and palate were able to do so. When comparing all cleft types, the V-Y palatoplasty resulted in a significantly higher percentage of velopharyngeal competence (74 per cent) than did the von Langenbeck method (56 per cent), although the data for the V-Y group are probably less reliable than those for the von Langenbeck group. In the soft palate only category, the results were slightly better with the von Langenbeck technique, though not significantly so. In all other cleft types, the results with the V-Y method were better than those with the von Langenbeck.

  13. Results of The Comparative Study of 200 Cases: One Anastomosis Gastric Bypass vs Roux-en-Y Gastric Bypass.

    PubMed

    Navarrete, Salvador; Leyba, José Luis; Ll, Salvador Navarrete; Borjas, Guillermo; Tapia, José León; Alcázar, Ruben

    2018-05-01

    Obesity has experienced worldwide increase and surgery has become the treatment that has achieved the best results. Several techniques have been described; the most popular are vertical gastrectomy (GV) and the Roux-en-Y gastric bypass (RYGB). However, mini-gastric bypass/one anastomosis gastric bypass (MGB/OAGB) has gained popularity due to its simplicity and good results. To comparatively evaluate the results of MGB/OAGB with those of RYGB with 1-year follow-up. The paper presents a comparative case and control study of 100 patients that underwent MGB/OAGB surgery and another 100 with RYGB surgery, operated between 2008 and 2016. Patients were not submitted to revision surgery and had the following pre-operative variables: age 40.46 ± 12.4 vs. 39.43 ± 10.33 years; sex 64 and 54 women, 36 and 46 men; BMI 44.8 ± 12.06 and 45.29 ± 8.82 kg/m 2 ; 50 and 54 cases with comorbidities, respectively, these being non-significant differences. The surgical time was 69.01 ± 4.62 (OAGB) vs. 88.98 ± 3.44 min; the time of hospitalization was 2 days, reaching a BMI of 27.7 ± 7.85 and 29 ± 4.52 kg/m 2 , with an excess weight loss 1 year after surgery of 89.4 vs. 85.9%, respectively. The morbidity rates are 9% for OAGB and 11% for the RYGB. There was a comorbidity resolution of 84.4 and 83.7% respectively, without mortality. The results show the benefits of both techniques, OAGB being the easiest to perform and with less surgical time.

  14. 40 CFR 1515.10 - Obtaining available information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Obtaining available information. 1515.10 Section 1515.10 Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY FREEDOM OF INFORMATION ACT PROCEDURES Availability of Information § 1515.10 Obtaining available information. (a) When a...

  15. Syngas Production from Pyrolysis of Nine Composts Obtained from Nonhybrid and Hybrid Perennial Grasses

    PubMed Central

    Hlavsová, Adéla; Raclavská, Helena; Juchelková, Dagmar; Škrobánková, Hana; Frydrych, Jan

    2014-01-01

    A pyrolysis of compost for the production of syngas with an explicit H2/CO = 2 or H2/CO = 3 was investigated in this study. The composts were obtained from nonhybrid (perennial) grasses (NHG) and hybrid (perennial) grasses (HG). Discrepancies in H2 evolution profiles were found between NHG and HG composts. In addition, positive correlations for NHG composts were obtained between (i) H2 yield and lignin content, (ii) H2 yield and potassium content, and (iii) CO yield and cellulose content. All composts resulted in H2/CO = 2 and five of the nine composts resulted in H2/CO = 3. Exceptionally large higher heating values (HHVs) of pyrolysis gas, very close to HHVs of feedstock, were obtained for composts made from mountain brome (MB, 16.23 MJ/kg), hybrid Becva (FB, 16.45 MJ/kg), and tall fescue (TF, 17.43 MJ/kg). The MB and FB composts resulted in the highest syngas formation with H2/CO = 2, whereas TF compost resulted in the highest syngas formation with H2/CO = 3. PMID:25101320

  16. Technical note: A device for obtaining time-integrated samples of ruminal fluid

    USGS Publications Warehouse

    Corley, R. N.; Murphy, M.R.; Lucena, J.; Panno, S.V.

    1999-01-01

    A device was adapted to allow for time-integrated sampling of fluid from the rumen via a cannula. The sampler consisted of a cup-shaped ceramic filter positioned in the ventral rumen of a cannulated cow and attached to a tube through which fluid entering the filter was removed continuously using a peristaltic pump. Rate of ruminal fluid removal using the device was monitored over two 36-h periods (at 6-h intervals) and was not affected (P > .05) by time, indicating that the system was not susceptible to clogging during this period. Two cows having ad libitum access to a totally mixed ration were used in a split-block design to evaluate the utility of the system for obtaining time-integrated samples of ruminal fluid. Ruminal fluid VFA concentration and pattern in samples collected in two replicated 8-h periods by the time-integrated sampler (at 1-h intervals) were compared with composite samples collected using a conventional suction-strainer device (at 30-min intervals). Each 8-h collection period started 2 h before or 6 h after feeding. Results indicated that total VFA concentration was not affected (P > .05) by the sampling method. Volatile fatty acid patterns were likewise unaffected (P > .05) except that acetate was 2.5% higher (P < .05) in samples collected 2 h before feeding and valerate was 5% higher (P < .05) in samples collected 6 h after feeding by the suction-strainer device. Although significant, these differences were not considered physiologically important. We concluded that use of the ceramic filter improved the sampling of ruminal fluid by simplifying the technique and allowing time-integrated samples to be obtained.

  17. 15 CFR 748.2 - Obtaining forms; mailing addresses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Obtaining forms; mailing addresses... APPLICATIONS (CLASSIFICATION, ADVISORY, AND LICENSE) AND DOCUMENTATION § 748.2 Obtaining forms; mailing addresses. (a) You may obtain the forms required by the EAR from any U.S. Department of Commerce District...

  18. Doping evolution of charge and spin excitations in two-leg Hubbard ladders: Comparing DMRG and FLEX results [Doping evolution of charge and spin excitations in two-leg Hubbard ladders: Comparing DMRG and RPA+FLEX results

    DOE PAGES

    Nocera, Alberto; Wang, Yan; Patel, Niravkumar D.; ...

    2018-05-31

    Here, we study the magnetic and charge dynamical response of a Hubbard model in a two-leg ladder geometry using the density matrix renormalization group (DMRG) method and the random phase approximation within the fluctuation-exchange approximation (FLEX). Our calculations reveal that FLEX can capture the main features of the magnetic response from weak up to intermediate Hubbard repulsion for doped ladders, when compared with the numerically exact DMRG results. However, while at weak Hubbard repulsion both the spin and charge spectra can be understood in terms of weakly interacting electron-hole excitations across the Fermi surface, at intermediate coupling DMRG shows gappedmore » spin excitations at large momentum transfer that remain gapless within the FLEX approximation. For the charge response, FLEX can only reproduce the main features of the DMRG spectra at weak coupling and high doping levels, while it shows an incoherent character away from this limit. Overall, our analysis shows that FLEX works surprisingly well for spin excitations at weak and intermediate Hubbard U values even in the difficult low-dimensional geometry such as a two-leg ladder. Finally, we discuss the implications of our results for neutron scattering and resonant inelastic x-ray scattering experiments on two-leg ladder cuprate compounds.« less

  19. Doping evolution of charge and spin excitations in two-leg Hubbard ladders: Comparing DMRG and FLEX results [Doping evolution of charge and spin excitations in two-leg Hubbard ladders: Comparing DMRG and RPA+FLEX results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nocera, Alberto; Wang, Yan; Patel, Niravkumar D.

    Here, we study the magnetic and charge dynamical response of a Hubbard model in a two-leg ladder geometry using the density matrix renormalization group (DMRG) method and the random phase approximation within the fluctuation-exchange approximation (FLEX). Our calculations reveal that FLEX can capture the main features of the magnetic response from weak up to intermediate Hubbard repulsion for doped ladders, when compared with the numerically exact DMRG results. However, while at weak Hubbard repulsion both the spin and charge spectra can be understood in terms of weakly interacting electron-hole excitations across the Fermi surface, at intermediate coupling DMRG shows gappedmore » spin excitations at large momentum transfer that remain gapless within the FLEX approximation. For the charge response, FLEX can only reproduce the main features of the DMRG spectra at weak coupling and high doping levels, while it shows an incoherent character away from this limit. Overall, our analysis shows that FLEX works surprisingly well for spin excitations at weak and intermediate Hubbard U values even in the difficult low-dimensional geometry such as a two-leg ladder. Finally, we discuss the implications of our results for neutron scattering and resonant inelastic x-ray scattering experiments on two-leg ladder cuprate compounds.« less

  20. Assessing representativeness of sampling methods for reaching men who have sex with men: a direct comparison of results obtained from convenience and probability samples.

    PubMed

    Schwarcz, Sandra; Spindler, Hilary; Scheer, Susan; Valleroy, Linda; Lansky, Amy

    2007-07-01

    Convenience samples are used to determine HIV-related behaviors among men who have sex with men (MSM) without measuring the extent to which the results are representative of the broader MSM population. We compared results from a cross-sectional survey of MSM recruited from gay bars between June and October 2001 to a random digit dial telephone survey conducted between June 2002 and January 2003. The men in the probability sample were older, better educated, and had higher incomes than men in the convenience sample, the convenience sample enrolled more employed men and men of color. Substance use around the time of sex was higher in the convenience sample but other sexual behaviors were similar. HIV testing was common among men in both samples. Periodic validation, through comparison of data collected by different sampling methods, may be useful when relying on survey data for program and policy development.

  1. Positional quality assessment of orthophotos obtained from sensors onboard multi-rotor UAV platforms.

    PubMed

    Mesas-Carrascosa, Francisco Javier; Rumbao, Inmaculada Clavero; Berrocal, Juan Alberto Barrera; Porras, Alfonso García-Ferrer

    2014-11-26

    In this study we explored the positional quality of orthophotos obtained by an unmanned aerial vehicle (UAV). A multi-rotor UAV was used to obtain images using a vertically mounted digital camera. The flight was processed taking into account the photogrammetry workflow: perform the aerial triangulation, generate a digital surface model, orthorectify individual images and finally obtain a mosaic image or final orthophoto. The UAV orthophotos were assessed with various spatial quality tests used by national mapping agencies (NMAs). Results showed that the orthophotos satisfactorily passed the spatial quality tests and are therefore a useful tool for NMAs in their production flowchart.

  2. Modifications of Atlantic salmon by-product oil for obtaining different ω-3 polyunsaturated fatty acids concentrates: An approach to comparative analysis.

    PubMed

    Haq, Monjurul; Park, Seul-Ki; Kim, Min-Jung; Cho, Yeon-Jin; Chun, Byung-Soo

    2018-04-01

    Omega-3 polyunsaturated fatty acids (ω-3 PUFAs) rich 2-monoacylglycerols (2-MAG), omega-3 polyunsaturated free fatty acids (ω-3 PUFFAs) concentrate, and PUFA enriched acylglycerols were prepared from salmon frame bone oil (SFBO) by enzymatic alcoholysis, urea complexation, and enzymatic esterification, respectively. The yields of 2-MAG, ω-3 PUFFAs concentrate, and PUFA enriched acylglycerols were 40.25, 16.52, and 15.65%, respectively. ω-3 PUFFAs concentrate and PUFA enriched acylglycerols showed darker red color than SFBO and 2-MAG due to aggregation of astaxanthin pigment in ω-3 PUFFAs concentrate during urea complexation. The viscosity and specific gravity of SFBO and PUFA enriched acylglycerols showed similar values whereas 2-MAG and ω-3 PUFFAs showed significantly (p < 0.05) lower values. Stability parameters like acid value, peroxide value, free fatty acid value, and p-anisidine value of SFBO and ω-3 PUFAs concentrates were within acceptable limits except extreme high acid value and free fatty acid value of ω-3 PUFFAs concentrate. Thermogravimetric analysis showed similar and higher thermal stability of SFBO and PUFA enriched acylglycerols than 2-MAG and ω-3 PUFFAs concentrate. The ω-3 PUFAs content in 2-MAG, ω-3 PUFFAs concentrate, and PUFA enriched acylglycerols was increased to 20.81, 52.96, and 51.74% respectively from 13.54% in SFBO. ω-3 PUFFAs concentrate and PUFA enriched acylglycerols showed higher DPPH and ABTS radical scavenging activity than SFBO and 2-MAG. The results obtained from this study suggest the production of PUFA enriched acylglycerols rich in ω-3 PUFAs supplements from fish oil for human and pet animals. Copyright © 2017. Published by Elsevier B.V.

  3. Phylogenetic Analysis of Anaerobic Psychrophilic Enrichment Cultures Obtained from a Greenland Glacier Ice Core

    PubMed Central

    Sheridan, Peter P.; Miteva, Vanya I.; Brenchley, Jean E.

    2003-01-01

    The examination of microorganisms in glacial ice cores allows the phylogenetic relationships of organisms frozen for thousands of years to be compared with those of current isolates. We developed a method for aseptically sampling a sediment-containing portion of a Greenland ice core that had remained at −9°C for over 100,000 years. Epifluorescence microscopy and flow cytometry results showed that the ice sample contained over 6 × 107 cells/ml. Anaerobic enrichment cultures inoculated with melted ice were grown and maintained at −2°C. Genomic DNA extracted from these enrichments was used for the PCR amplification of 16S rRNA genes with bacterial and archaeal primers and the preparation of clone libraries. Approximately 60 bacterial inserts were screened by restriction endonuclease analysis and grouped into 27 unique restriction fragment length polymorphism types, and 24 representative sequences were compared phylogenetically. Diverse sequences representing major phylogenetic groups including alpha, beta, and gamma Proteobacteria as well as relatives of the Thermus, Bacteroides, Eubacterium, and Clostridium groups were found. Sixteen clone sequences were closely related to those from known organisms, with four possibly representing new species. Seven sequences may reflect new genera and were most closely related to sequences obtained only by PCR amplification. One sequence was over 12% distant from its closest relative and may represent a novel order or family. These results show that phylogenetically diverse microorganisms have remained viable within the Greenland ice core for at least 100,000 years. PMID:12676695

  4. Valuable natural products from marine and freshwater macroalgae obtained from supercritical fluid extracts.

    PubMed

    Messyasz, Beata; Michalak, Izabela; Łęska, Bogusława; Schroeder, Grzegorz; Górka, Bogusława; Korzeniowska, Karolina; Lipok, Jacek; Wieczorek, Piotr; Rój, Edward; Wilk, Radosław; Dobrzyńska-Inger, Agnieszka; Górecki, Henryk; Chojnacka, Katarzyna

    2018-01-01

    The biologically active compounds (fatty acids, pigments, phenolics, and flavonoid content) were studied in supercritical fluid extracts from the biomass of marine ( Ulva clathrata , Cladophora glomerata , Polysiphonia fucoides , and their multi-species mixture) and freshwater ( C. glomerata ) macroalgae. Different extraction techniques were used in order to compare differences in the biologically active compound composition of the macroalgal extracts. The results indicated that the saturated and unsaturated fatty acids ranged from C9:0 to C22:0. The analysis of differences in the composition of unsaturated to saturated fatty acids in extracts showed that palmitic acid (C16:0) and oleic acid (C18:1, n-9) reached the highest value not only in marine monospecies and multi-species biomass but also in the freshwater macroalga C. glomerata . When comparing the similarity between the concentration of fatty acids and the ratio of the concentration of unsaturated fatty acids to saturated in macroalgal extracts, we found small but not statistically significant variations in values between years (up to 10%). This is acceptable for applications as a stable raw material for industrial purposes. Significantly higher values of fatty acids, carotenoids, and chlorophylls were obtained in the case of SC-CO 2 extraction. The active ingredients of polyphenols, possessing antioxidant activity ranged from approximately 2-4%. Moreover, flavonoids represented less than 10% of the total content of polyphenolic compounds. The extraction efficiency of polyphenols was higher from a mixture of marine algae for the ultrasound-assisted extraction compared to freshwater. All these findings show that marine and freshwater macroalgae, as a raw material, have the optimal biologically active compounds composition for cosmetics.

  5. 48 CFR 209.105-1 - Obtaining information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Information Retrieval System (PPIRS), available at http://www.ppirs.gov. Information relating to contract... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Obtaining information. 209....105-1 Obtaining information. (1) For guidance on using the Excluded Parties List System, see PGI 209...

  6. 48 CFR 209.105-1 - Obtaining information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Performance Information Retrieval System (PPIRS), available at http://www.ppirs.gov. Information relating to... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Obtaining information. 209....105-1 Obtaining information. (1) For guidance on using the System for Award Management Exclusions, see...

  7. 48 CFR 209.105-1 - Obtaining information.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Information Retrieval System (PPIRS), available at http://www.ppirs.gov. Information relating to contract... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Obtaining information. 209....105-1 Obtaining information. (1) For guidance on using the Excluded Parties List System, see PGI 209...

  8. 48 CFR 209.105-1 - Obtaining information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Information Retrieval System (PPIRS), available at http://www.ppirs.gov. Information relating to contract... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Obtaining information. 209....105-1 Obtaining information. (1) For guidance on using the Excluded Parties List System, see PGI 209...

  9. 46 CFR 188.35-5 - Where obtainable.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Where obtainable. 188.35-5 Section 188.35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS American Bureau of Shipping's Standards § 188.35-5 Where obtainable. (a) The standards established...

  10. 46 CFR 188.35-5 - Where obtainable.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Where obtainable. 188.35-5 Section 188.35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS American Bureau of Shipping's Standards § 188.35-5 Where obtainable. (a) The standards established...

  11. 46 CFR 188.35-5 - Where obtainable.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Where obtainable. 188.35-5 Section 188.35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS American Bureau of Shipping's Standards § 188.35-5 Where obtainable. (a) The standards established...

  12. 46 CFR 188.35-5 - Where obtainable.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Where obtainable. 188.35-5 Section 188.35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS American Bureau of Shipping's Standards § 188.35-5 Where obtainable. (a) The standards established...

  13. 46 CFR 188.35-5 - Where obtainable.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Where obtainable. 188.35-5 Section 188.35-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS GENERAL PROVISIONS American Bureau of Shipping's Standards § 188.35-5 Where obtainable. (a) The standards established...

  14. 48 CFR 509.105-1 - Obtaining information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Obtaining information. 509... Obtaining information. (a) From a prospective contractor. FAR 9.105-1 lists a number of sources of information that a contracting officer may utilize before making a determination of responsibility. The...

  15. 48 CFR 509.105-1 - Obtaining information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Obtaining information. 509... Obtaining information. (a) From a prospective contractor. FAR 9.105-1 lists a number of sources of information that a contracting officer may utilize before making a determination of responsibility. The...

  16. 48 CFR 509.105-1 - Obtaining information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Obtaining information. 509... Obtaining information. (a) From a prospective contractor. FAR 9.105-1 lists a number of sources of information that a contracting officer may utilize before making a determination of responsibility. The...

  17. 48 CFR 509.105-1 - Obtaining information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Obtaining information. 509... Obtaining information. (a) From a prospective contractor. FAR 9.105-1 lists a number of sources of information that a contracting officer may utilize before making a determination of responsibility. The...

  18. Younger people with Type 2 diabetes have poorer self-care practices compared with older people: results from the Australian National Diabetes Audit.

    PubMed

    Nanayakkara, N; Pease, A J; Ranasinha, S; Wischer, N; Andrikopoulos, S; de Courten, B; Zoungas, S

    2018-05-05

    This cross-sectional study compares the self-care practices of younger and older people with Type 2 diabetes. Data were analysed from the Australian National Diabetes Audit (ANDA) including 2552 adults with Type 2 diabetes from Australian Diabetes Centres. Pre-specified demographic and clinical variables were obtained. Self-care variables (physical activity, following dietary recommendations, medication adherence and monitoring blood glucose levels) were compared in people ≤ 64 and > 64 years of age. Mean age (± sd) of participants was 63 ± 13 years overall, 53 ± 9 years for the younger group and 73 ± 6 years for the older group. A greater proportion of younger people had HbA 1c levels > 53 mmol/mol (> 7.0%) (76% vs. 68%), reported difficulty following dietary recommendations (50% vs. 32%) and forgetting medications (37% vs. 22%) compared with older people (all P-values <0.001). A smaller proportion of younger compared with older people reported monitoring their blood glucose levels as often as recommended (60% vs. 70%, P < 0.001). Similar proportions of people aged ≤ 64 and > 64 years required insulin therapy (59% vs. 57%, P = 0.200). Younger age was associated with a twofold increase in the odds of not following the recommended self-care practices after adjustment for gender, smoking, insulin therapy, depression and allied health attendance (all P < 0.001). Despite shorter diabetes duration, younger age was associated with worse glycaemic control and poorer diabetes self-care practices among people with Type 2 diabetes. Targeted strategies are required to optimize diabetes self-care practices and thereby glycaemic control. © 2018 Diabetes UK.

  19. Summary of experimental heat-transfer results from the turbine hot section facility

    NASA Technical Reports Server (NTRS)

    Gladden, Herbert J.; Yeh, Fredrick C.

    1993-01-01

    Experimental data from the turbine Hot Section Facility are presented and discussed. These data include full-coverage film-cooled airfoil results as well as special instrumentation results obtained at simulated real engine conditions. Local measurements of airfoil wall temperature, airfoil gas-path static-pressure distribution, and local heat-transfer coefficient distributions are presented and discussed. In addition, measured gas and coolant temperatures and pressures are presented. These data are also compared with analyses from Euler and boundary-layer codes.

  20. Unambiguous determination of H-atom positions: comparing results from neutron and high-resolution X-ray crystallography.

    PubMed

    Gardberg, Anna S; Del Castillo, Alexis Rae; Weiss, Kevin L; Meilleur, Flora; Blakeley, Matthew P; Myles, Dean A A

    2010-05-01

    The locations of H atoms in biological structures can be difficult to determine using X-ray diffraction methods. Neutron diffraction offers a relatively greater scattering magnitude from H and D atoms. Here, 1.65 A resolution neutron diffraction studies of fully perdeuterated and selectively CH(3)-protonated perdeuterated crystals of Pyrococcus furiosus rubredoxin (D-rubredoxin and HD-rubredoxin, respectively) at room temperature (RT) are described, as well as 1.1 A resolution X-ray diffraction studies of the same protein at both RT and 100 K. The two techniques are quantitatively compared in terms of their power to directly provide atomic positions for D atoms and analyze the role played by atomic thermal motion by computing the sigma level at the D-atom coordinate in simulated-annealing composite D-OMIT maps. It is shown that 1.65 A resolution RT neutron data for perdeuterated rubredoxin are approximately 8 times more likely overall to provide high-confidence positions for D atoms than 1.1 A resolution X-ray data at 100 K or RT. At or above the 1.0sigma level, the joint X-ray/neutron (XN) structures define 342/378 (90%) and 291/365 (80%) of the D-atom positions for D-rubredoxin and HD-rubredoxin, respectively. The X-ray-only 1.1 A resolution 100 K structures determine only 19/388 (5%) and 8/388 (2%) of the D-atom positions above the 1.0sigma level for D-rubredoxin and HD-rubredoxin, respectively. Furthermore, the improved model obtained from joint XN refinement yielded improved electron-density maps, permitting the location of more D atoms than electron-density maps from models refined against X-ray data only.