Sample records for obtained venous blood

  1. Comparison of Oseltamivir and Oseltamivir Carboxylate Concentrations in Venous Plasma, Venous Blood, and Capillary Blood in Healthy Volunteers

    PubMed Central

    Instiaty, Insti; Lindegardh, Niklas; Jittmala, Podjanee; Hanpithakpong, Warunee; Blessborn, Daniel; Pukrittayakamee, Sasithon; White, Nicholas J.

    2013-01-01

    Oseltamivir and oseltamivir carboxylate concentrations were measured in venous plasma, venous blood, and capillary blood taken simultaneously from 24 healthy volunteers. Median (range) venous-blood-to-plasma ratios were 1.42 (0.920 to 1.97) for oseltamivir and 0.673 (0.564 to 0.814) for oseltamivir carboxylate. Capillary blood/venous plasma ratios were 1.32 (0.737 to 3.16) for oseltamivir and 0.685 (0.502 to 1.34) for oseltamivir carboxylate. Oseltamivir concentrations in venous and capillary blood were similar. Oseltamivir carboxylate showed a time-dependent distribution between venous and capillary blood. PMID:23507284

  2. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  3. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  4. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  5. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Venous blood pressure manometer. 870.1140 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood pressure manometer. (a) Identification. A venous blood pressure manometer is a device attached to a venous...

  6. Reliability of blood color and blood gases in discriminating arterial from venous puncture during cardiopulmonary resuscitation.

    PubMed

    Park, Je Sung; Lee, Byung Kook; Jeung, Kyung Woon; Choi, Sung Soo; Park, Sang Wook; Song, Kyung Hwan; Lee, Sung Min; Heo, Tag; Min, Yong Il

    2015-04-01

    We investigated the use of blood color brightness and blood gas variables for discriminating arterial from venous puncture during cardiopulmonary resuscitation (CPR). The study's aims were to determine if discrimination using Po2 is superior to using blood color brightness, and if blood color brightness, Po2, and acid-base variables derived from blood gas analysis accurately discriminate arterial from venous blood during CPR. Fifteen pigs underwent ventricular fibrillation followed by CPR. During CPR, paired femoral arterial and venous blood samples were obtained, and 2 blinded observers were asked to identify the blood's origin. Blood color brightness was measured using a blood brightness scale (BBS). The discriminatory performances of the BBS and blood gas variables were evaluated by calculating the area under receiver operating characteristic curves (AUC). The observers accurately discriminated arterial from venous blood with a sensitivity of 97.0% (84.7%-99.5%) and specificity of 84.9% (69.1%-93.4%). The BBS (AUC = 0.983) and Po2 (AUC = 0.981) methods both showed comparable and excellent discriminatory performances. pH, Pco2, and HCO3(-) all discriminated arterial from venous blood (AUC = 0.831, 0.971, and 0.652, respectively). The AUC for Pco2 was comparable to that for Po2 but significantly larger than that for pH (P = .002) or HCO3(-) (P < .001). The BBS and Po2 methods showed comparable and excellent discrimination performances. Using pH, Pco2, and HCO3(-) levels also discriminated arterial from venous blood during CPR with statistical significance. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Vacuum-assisted venous return reduces blood usage.

    PubMed

    Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M

    2003-09-01

    To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased

  8. Measurement of T1 of human arterial and venous blood at 7T.

    PubMed

    Rane, Swati D; Gore, John C

    2013-04-01

    Techniques for measuring cerebral perfusion require accurate longitudinal relaxation (T1) of blood, an MRI parameter that is field dependent. T1 of arterial and venous human blood was measured at 7T using three different sources - pathology laboratory, blood bank and in vivo. The T1 of venous blood was measured from sealed samples from a pathology lab and in vivo. Samples from a blood bank were oxygenated and mixed to obtain different physiological concentrations of hematocrit and oxygenation. T1 relaxation times were estimated using a three-point fit to a simple inversion recovery equation. At 37°C, the T1 of blood at arterial pO2 was 2.29±0.1s and 2.07±0.12 at venous pO2. The in vivo T1 of venous blood, in three subjects, was slightly longer at 2.45±0.11s. T1 of arterial and venous blood at 7T was measured and found to be significantly different. The T1 values were longer in vivo than in vitro. While the exact cause for the discrepancy is unknown, the additives in the blood samples, degradation during experiment, oxygenation differences, and the non-stagnant nature of blood in vivo could be potential contributors to the lower values of T1 in the venous samples. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Venous saturation and blood flow behavior during laser-induced photodissociation of oxyhemoglobin

    NASA Astrophysics Data System (ADS)

    Mamilov, S. A.; Yesman, S. S.; Asimov, M. M.; Gisbrecht, A. I.

    2013-03-01

    The value of relative oxyhemoglobin concentration (saturation) in arterial (SаO2) and venous blood (SvO2) plays a significant role in the oxygen exchange in tissue and is used as criterion of delivery of oxygen adequate to the needs of tissue cells. Reduction of the volume of blood flows as well as reduction of oxygen concentration in arterial blood causes hypoxia - deficit of oxygen in tissue. One of the main mechanisms of elimination of hypoxia is based on compensation of the oxygen deficit by increasing the oxygen extraction from arterial blood, which leads to reduction of oxygen in the venous blood 1. In this report two optical techniques for measurement of venous blood saturation are presented. The first one is based on the pulseoximetry with artificial mechanical modulation of the tissue volume and the second one on the spectrophotometry of human respiratory rhythm. Good correlation between the results obtained with both techniques is observed.

  10. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    PubMed

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.

  11. Erythrocyte volume in acidified venous blood from exercising limbs.

    NASA Technical Reports Server (NTRS)

    Van Beaumont, W.; Rochelle, R. H.

    1973-01-01

    Five male volunteers performed arm exercises in the sitting position by cranking the pedals of a bicycle ergometer at 50 revolutions per min. The initial mechanical work load of 0 kgm/min was increased every minute by 75 kgm/min until exhaustion occurred. The data obtained show a significant acidification of the venous blood from the working arms and a substantial increase in venous pCO2 during this type of muscular activity. However, the erythrocyte volume remained unaltered during the exercise.

  12. [Decreased retraction of blood clots in patients with venous thromboembolic complications].

    PubMed

    Bredikhin, R A; Peshkova, A D; Maliasev, D V; Batrakova, M V; Le Min, J; Panasiuk, M V; Fatkhullina, L S; Ignat'ev, I M; Khaĭrullin, R N; Litvinov, R I

    Haemostatic disorders play an important role in the pathogenesis of acute venous thrombosis. One of the least studied reactions of blood coagulation and thrombogenesis is spontaneous contraction of blood clots, which takes place at the expense of the contractility apparatus of activated blood platelets adhered to fibrin fibres. The work was aimed at studying the parameters of contraction of blood clots, formed in vitro, in blood of 41 patients with acute venous thromboses as compared with the same parameters in apparently healthy donors. We used a new instrumental method making it possible to determine the time from initiation to the beginning of contraction, as well as the degree and velocity of clot contraction. It was revealed that in patients with venous thrombosis the ability of clots to shrink was significantly reduced as compared with the control. We detected a statistically significant retardation of and decrease in of blood clot concentration in patients with venous thrombosis complicated by pulmonary artery thromboembolism as compared with contraction in patients with isolated deep vein thrombosis, witch may be important for early diagnosis and determination of the risk of thromboembolism. Besides, we revealed a statistically significant retardation of contraction in patients with proximal thrombosis as compared with contraction in patients with distal thrombosis, with similar values of the degree of contraction. Contraction was statistically significantly reduced in acute thrombosis (less than 21 days), whereas in subacute thrombosis (more than 21 days) the parameters of contraction were closer to normal values. The obtained findings suggest that reduction of blood clot contraction may be a new, hitherto unstudied pathogenetic mechanism deteriorating the course and outcome of venous thrombosis. The clinical significance of contraction and its impairments, as well as the diagnostic and prognostic value of the laboratory test for blood clot contraction

  13. Simultaneous detection of colonic epithelial cells in portal venous and peripheral blood during colorectal cancer surgery.

    PubMed

    Tien, Yu-Wen; Lee, Po-Huang; Wang, Shih-Ming; Hsu, Su-Ming; Chang, King-Jen

    2002-01-01

    This study was designed to show, in certain patients, that colonic epithelial cells can be present in peripheral blood while absent in portal venous blood. The circulating colorectal epithelial cells were detected by a reverse transcriptase-polymerase chain reaction assay, which involved amplifying guanylyl cyclase C transcripts. Portal venous and peripheral blood samples were obtained at intervals from 58 patients undergoing colorectal cancer surgery. Circulating colonic epithelial cells were more frequently detected in portal venous blood than in peripheral blood only before mobilization of the tumor-bearing colon segment in patients with tumors of Stage B. In five other patients, before mobilization of their tumor-bearing colon segments, and in another three patients, during the mobilization, colorectal epithelial cells were detected in peripheral blood but not in portal venous blood. These eight patients had Stage C or D tumors. In 8 of 58 patients, colorectal epithelial cells were detected in peripheral but not in portal venous blood. Metastatic deposits in lymphatic vessels or liver might be the source of these cells.

  14. 21 CFR 870.1140 - Venous blood pressure manometer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Venous blood pressure manometer. 870.1140 Section 870.1140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1140 Venous blood...

  15. Do capillary dried blood spot concentrations of gamma-hydroxybutyric acid mirror those in venous blood? A comparative study.

    PubMed

    Sadones, Nele; Archer, John R H; Ingels, Ann-Sofie M E; Dargan, Paul I; Wood, David M; Wood, Michelle; Neels, Hugo; Lambert, Willy E; Stove, Christophe P

    2015-04-01

    Gamma-hydroxybutyric acid (GHB) is a well-known illicit club and date-rape drug. Dried blood spot (DBS) sampling is a promising alternative for classical venous sampling in cases of (suspected) GHB intoxication since it allows rapid sampling, which is of interest for the extensively metabolized GHB. However, there is limited data if -and how- capillary DBS concentrations correlate with venous concentrations. We conducted a comparative study in 50 patients with suspected GHB intoxication, to determine and to correlate GHB concentrations in venous DBS (vDBS) and capillary DBS (cDBS). This is the first study that evaluates in a large cohort the correlation between capillary and venous concentrations of an illicit drug in real-life samples. Of the 50 paired samples, 7 were excluded: the vDBS concentration was below the LLOQ of 2 µg/mL in 3 cases and 4 samples were excluded after visual inspection of the DBS. Bland-Altman analysis revealed a mean % difference of -2.8% between cDBS and vDBS concentrations, with the zero value included in the 95% confidence interval of the mean difference in GHB concentration. A paired sample t-test confirmed this observation (p = 0.17). Also the requirement for incurred sample reproducibility was fulfilled: for more than two-thirds of the samples the concentrations obtained in cDBS and those in vDBS were within 20% of their mean. Since equivalent concentrations were observed in cDBS and vDBS, blood obtained by fingerprick can be considered a valid alternative for venous blood for GHB determination. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Vasopressin and nitroglycerin decrease portal and hepatic venous pressure and hepato-splanchnic blood flow.

    PubMed

    Wisén, E; Svennerholm, K; Bown, L S; Houltz, E; Rizell, M; Lundin, S; Ricksten, S-E

    2018-03-26

    Various methods are used to reduce venous blood pressure in the hepato-splanchnic circulation, and hence minimise blood loss during liver surgery. Previous studies show that combination of vasopressin and nitroglycerin reduces portal pressure and flow in patients with portal hypertension, and in this study we investigated this combination in patients with normal portal pressure. In all, 13 patients were studied. Measurements were made twice to confirm baseline (C1 and BL), during vasopressin infusion 4.8 U/h (V), and during vasopressin infusion combined with nitroglycerin infusion (V + N). Portal venous pressure (PVP), hepatic venous pressure (HVP), central haemodynamics and arterial and venous blood gases were obtained at each measuring point, and portal (splanchnic) and hepato-splanchnic blood flow changes were calculated. Vasopressin alone did not affect PVP, whereas HVP increased slightly. In combination with nitroglycerin, PVP decreased from 10.1 ± 1.6 to 8.9 ± 1.3 mmHg (P < 0.0001), and HVP decreased from 7.9 ± 1.9 to 6.2 ± 1.3 mmHg (P = 0.001). Vasopressin reduced portal blood flow by 47 ± 19% and hepatic venous flow by 11 ± 18%, respectively. Addition of nitroglycerin further reduced portal- and hepatic flow by 55 ± 13% and 30 ± 13%, respectively. Vasopressin alone had minor effects on central haemodynamics, whereas addition of nitroglycerin reduced cardiac index (3.2 ± 0.7 to 2.7 ± 0.5; P < 0.0001). The arterial-portal vein lactate gradient was unaffected. The combination of vasopressin and nitroglycerin decreases portal pressure and hepato-splanchnic blood flow, and could be a potential treatment to reduce bleeding in liver resection surgery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Comparison of EML 105 and advantage analysers measuring capillary versus venous whole blood glucose in neonates.

    PubMed

    McNamara, P J; Sharief, N

    2001-09-01

    Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. Whole blood glucose concentrations ranging from 0 to 3.5 mmol/l were carefully prepared in a laboratory setting and blood samples from each respective solution were then measured by EML 105 and Advantage analysers. The results obtained were then compared with the corresponding plasma glucose reading obtained by the Hexokinase method, using linear regression analysis. An in vivo study was subsequently performed on 103 neonates, over a 1-y period, using capillary and venous whole blood samples. Whole blood glucose concentration was estimated from each sample using both analysers and compared with the corresponding plasma glucose concentration estimated by the Hexokinase method. Venous blood was centrifuged and haematocrit was estimated using standardized curves. The effect of haematocrit on the agreement between whole blood and plasma glucose was investigated, estimating the degree of correlation on a scatterplot of the results and linear regression analysis. Both the EML 105 and Hexokinase methods were highly accurate, in vitro, with small proportional biases of 2% and 5%, respectively. However, in vivo, both study analysers overestimated neonatal plasma glucose, ranging from at best 0.45 mmol/l (EML 105 venous) to 0.69 mmol/l (EML capillary). There was no significant difference in the agreement of capillary (GD = 0.12, 95% CI, [-0.32,0.08], p = 0.2) or venous samples (GD = 0.05, 95% CI. [0.09, 0.19], p = 0.49) with plasma glucose when analysed by either study method

  18. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    PubMed

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  19. A content validated questionnaire for assessment of self reported venous blood sampling practices

    PubMed Central

    2012-01-01

    Background Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. Findings We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. Conclusions The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward. PMID:22260505

  20. A content validated questionnaire for assessment of self reported venous blood sampling practices.

    PubMed

    Bölenius, Karin; Brulin, Christine; Grankvist, Kjell; Lindkvist, Marie; Söderberg, Johan

    2012-01-19

    Venous blood sampling is a common procedure in health care. It is strictly regulated by national and international guidelines. Deviations from guidelines due to human mistakes can cause patient harm. Validated questionnaires for health care personnel can be used to assess preventable "near misses"--i.e. potential errors and nonconformities during venous blood sampling practices that could transform into adverse events. However, no validated questionnaire that assesses nonconformities in venous blood sampling has previously been presented. The aim was to test a recently developed questionnaire in self reported venous blood sampling practices for validity and reliability. We developed a questionnaire to assess deviations from best practices during venous blood sampling. The questionnaire contained questions about patient identification, test request management, test tube labeling, test tube handling, information search procedures and frequencies of error reporting. For content validity, the questionnaire was confirmed by experts on questionnaires and venous blood sampling. For reliability, test-retest statistics were used on the questionnaire answered twice. The final venous blood sampling questionnaire included 19 questions out of which 9 had in total 34 underlying items. It was found to have content validity. The test-retest analysis demonstrated that the items were generally stable. In total, 82% of the items fulfilled the reliability acceptance criteria. The questionnaire could be used for assessment of "near miss" practices that could jeopardize patient safety and gives several benefits instead of assessing rare adverse events only. The higher frequencies of "near miss" practices allows for quantitative analysis of the effect of corrective interventions and to benchmark preanalytical quality not only at the laboratory/hospital level but also at the health care unit/hospital ward.

  1. Measurement of tafenoquine (WR 238605) in human plasma and venous and capillary blood by high-pressure liquid chromatography.

    PubMed

    Kocisko, D A; Walsh, D S; Eamsila, C; Edstein, M D

    2000-04-01

    A simple, rapid, and accurate high-pressure liquid chromatographic method with fluorescence detection is described for the measurement of tafenoquine (TQ) (also known as WR 238605) from human plasma and venous and capillary blood. Tafenoquine was measured in plasma and venous blood following protein precipitation. Chromatographic separation was achieved using a Waters S5P Spherisorb phenyl analytical cartridge (150 mm x 4.6 mm I.D., 5 microm particle size) (Waters, Milford, MA, USA) and a mobile phase of 22 mM ammonium acetate, pH 4:acetonitrile (45:55, vol/vol). The flow rate was 1.5 mL/min and the retention times were approximately 3.5 min for WR VIIIAc (internal standard) and approximately 7.8 min for TQ. The interday and intraday coefficients of variation of TQ over a concentration range of 20-1000 ng/mL in plasma were < or =8.4% and in venous blood were < or =9.6%. The mean percent difference between added concentration and obtained concentration was 7.3% in plasma and 8.5% in venous blood over the corresponding concentration range. The limit of quantitation for both fluids was 10 ng/mL. Tafenoquine concentrations were comparable between capillary and venous blood with no significant difference between measurement in both biological fluids. The clinical application of the method was demonstrated by measuring plasma and whole blood concentrations of TQ from participants in a chemosuppression trial of the drug against malaria infections in Thailand.

  2. Do the venous blood samples replicate malaria parasite densities found in capillary blood? A field study performed in naturally-infected asymptomatic children in Cameroon.

    PubMed

    Sandeu, Maurice M; Bayibéki, Albert N; Tchioffo, Majoline T; Abate, Luc; Gimonneau, Geoffrey; Awono-Ambéné, Parfait H; Nsango, Sandrine E; Diallo, Diadier; Berry, Antoine; Texier, Gaétan; Morlais, Isabelle

    2017-08-17

    The measure of new drug- or vaccine-based approaches for malaria control is based on direct membrane feeding assays (DMFAs) where gametocyte-infected blood samples are offered to mosquitoes through an artificial feeder system. Gametocyte donors are identified by the microscopic detection and quantification of malaria blood stages on blood films prepared using either capillary or venous blood. However, parasites are known to sequester in the microvasculature and this phenomenon may alter accurate detection of parasites in blood films. The blood source may then impact the success of mosquito feeding experiments and investigations are needed for the implementation of DMFAs under natural conditions. Thick blood smears were prepared from blood obtained from asymptomatic children attending primary schools in the vicinity of Mfou (Cameroon) over four transmission seasons. Parasite densities were determined microscopically from capillary and venous blood for 137 naturally-infected gametocyte carriers. The effect of the blood source on gametocyte and asexual stage densities was then assessed by fitting cumulative link mixed models (CLMM). DMFAs were performed to compare the infectiousness of gametocytes from the different blood sources to mosquitoes. Prevalence of Plasmodium falciparum asexual stages among asymptomatic children aged from 4 to 15 years was 51.8% (2116/4087). The overall prevalence of P. falciparum gametocyte carriage was 8.9% and varied from one school to another. No difference in the density of gametocyte and asexual stages was found between capillary and venous blood. Attempts to perform DMFAs with capillary blood failed. Plasmodium falciparum malaria parasite densities do not differ between capillary and venous blood in asymptomatic subjects for both gametocyte and trophozoite stages. This finding suggests that the blood source should not interfere with transmission efficiency in DMFAs.

  3. Novel optoacoustic system for noninvasive continuous monitoring of cerebral venous blood oxygenation

    NASA Astrophysics Data System (ADS)

    Petrov, Yuriy; Petrov, Irene Y.; Prough, Donald S.; Esenaliev, Rinat O.

    2012-02-01

    Traumatic brain injury (TBI) and spinal cord injury are a major cause of death for individuals under 50 years of age. In the USA alone, 150,000 patients per year suffer moderate or severe TBI. Moreover, TBI is a major cause of combatrelated death. Monitoring of cerebral venous blood oxygenation is critically important for management of TBI patients because cerebral venous blood oxygenation below 50% results in death or severe neurologic complications. At present, there is no technique for noninvasive, accurate monitoring of this clinically important variable. We proposed to use optoacoustic technique for noninvasive monitoring of cerebral venous blood oxygenation by probing cerebral veins such as the superior sagittal sinus (SSS) and validated it in animal studies. In this work, we developed a novel, medical grade optoacoustic system for continuous, real-time cerebral venous blood oxygenation monitoring and tested it in human subjects at normal conditions and during hyperventilation to simulate changes that may occur in patients with TBI. We designed and built a highly-sensitive optoacoustic probe for SSS signal detection. Continuous measurements were performed in the near infrared spectral range and the SSS oxygenation absolute values were automatically calculated in real time using a special algorithm developed by our group. Continuous measurements performed at normal conditions and during hyperventilation demonstrated that hyperventilation resulted in approximately 12% decrease of cerebral venous blood oxygenation.

  4. Brightness of venous blood in South American camelids: implications for jugular catheterization.

    PubMed

    Grint, Nicola; Dugdale, Alexandra

    2009-01-01

    To compare the brightness of South American camelid venous blood to that of Equidae. Prospective clinical evaluation. Twelve South American camelids (eight llamas, four alpacas), eight horses and ponies (control group). Appropriately sized catheters were placed in the jugular vein of each animal under local anaesthesia. The blood spilt before the catheter was capped was caught on a white tile. A sample of blood was drawn for blood-gas analysis. The brightness of the blood (both on the tile and in the syringe) was matched to a colour chart (1 = darkest red, 8 = brightest red) by a single observer under bright light conditions. Packed cell volume (PCV) and partial pressure of oxygen (PvO(2)) in the blood were also measured on the syringe blood. Normally distributed data were compared using a two tailed t-test, and non-normally distributed data were compared using a Mann-Whitney U-test. Significance was set at p < 0.05. Camelid venous blood was significantly brighter red than that of horses and ponies both on the white tile (p = 0.0003) and in the syringe (p = 0.0001). PCV was significantly lower in camelids (32 +/- 4%) compared with horses (37 +/- 5%). Partial pressure of oxygen values were similar between groups. Jugular venous blood in alpacas and llamas is significantly brighter red than that of horses. Colour should not be used as a sole determinant of venous or arterial catheterization in this species.

  5. Venous return curves obtained from graded series of valsalva maneuvers

    NASA Technical Reports Server (NTRS)

    Mastenbrook, S. M., Jr.

    1974-01-01

    The effects were studied of a graded series of valsalva-like maneuvers on the venous return, which was measured transcutaneously in the jugular vein of an anesthetized dog, with the animal serving as its own control. At each of five different levels of central venous pressure, the airway pressure which just stopped venous return during each series of maneuvers was determined. It was found that this end-point airway pressure is not a good estimator of the animal's resting central venous pressure prior to the simulated valsalva maneuver. It was further found that the measured change in right atrial pressure during a valsalva maneuver is less than the change in airway pressure during the same maneuver, instead of being equal, as had been expected. Relative venous return curves were constructed from the data obtained during the graded series of valsalva maneuvers.

  6. Malaria PCR Detection in Cambodian Low-Transmission Settings: Dried Blood Spots versus Venous Blood Samples

    PubMed Central

    Canier, Lydie; Khim, Nimol; Kim, Saorin; Eam, Rotha; Khean, Chanra; Loch, Kaknika; Ken, Malen; Pannus, Pieter; Bosman, Philippe; Stassijns, Jorgen; Nackers, Fabienne; Alipon, SweetC; Char, Meng Chuor; Chea, Nguon; Etienne, William; De Smet, Martin; Kindermans, Jean-Marie; Ménard, Didier

    2015-01-01

    In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 μL) and different volumes of venous blood (50 μL, 200 μL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 μL, 200 μL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, ∼100-fold lower than 5 μL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 μL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas. PMID:25561570

  7. Comparison of Interstitial Fluid pH, PCO2, PO2 with Venous Blood Values During Repetitive Handgrip Exercise

    NASA Technical Reports Server (NTRS)

    Hagan, Ronald Donald; Soller, Babs R.; Shear, Michael; Walz, Matthias; Landry, Michelle; Heard, Stephen

    2006-01-01

    We evaluated the use of a small, fiber optic sensor to measure pH, PCO2 and PO2 from forearm muscle interstitial fluid (IF) during handgrip dynamometry. PURPOSE: Compare pH, PCO2 and PO2 values obtained from venous blood with those from the IF of the flexor digitorum superficialis (FDS) during three levels of exercise intensity. METHODS: Six subjects (5M/1F), average age 29+/-5 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space and a fiber optic sensor (Paratrend, Diametrics Medical, Inc.) was placed through a 22 G catheter into the FDS muscle under ultrasound guidance. After a 45 min rest period, subjects performed three 5-min bouts of repetitive handgrip exercise (2s contraction/1 s relaxation) at attempted levels of 15%, 30% and 45% of maximal voluntary contraction. The order of the exercise bouts was random with the second and third bouts started after blood lactate had returned to baseline. Venous blood was sampled every minute during exercise and analyzed with an I-Stat CG-4+ cartridge, while IF fiber optic sensor measurements were obtained every 2 s. Change from pre-exercise baseline to end of exercise was computed for pH, PCO2 and PO2. Blood and IF values were compared with a paired t-test. RESULTS: Baseline values for pH, PCO2 and PO2 were 7.37+/-0.02, 46+/-4 mm Hg, and 36+/-6 mm Hg respectively in blood and 7.39+/-0.02, 44+/-6 mm Hg, and 35+/-14 mm Hg in IF. Average changes over all exercise levels are noted in the Table below. For each parameter the exercise-induced change was at least twice as great in IF as in blood. In blood and IF, pH and PCO2 increases were directly related to exercise intensity. Change in venous PO2 was unrelated to exercise intensity, while IF PO2 decreased with increases in exercise intensity. CONCLUSIONS: Measurement of IF pH, PCO2 and PO2 is more sensitive to exercise intensity than measurement of the same parameters in venous blood and provides continuous

  8. [Clinical value of ammonia determination in venous blood in chronic cor pulmonale].

    PubMed

    Szulc, E J; Sworzyńska, I

    1978-01-01

    The authors have examined 43 workers of the Warszawa works: 20 healthy persons and 23 with chronic pulmocardiac syndrome. An increased ammonia level in venous blood, above 48 gamma %, was found in those with chronic pulmocardiac syndrome with simultaneous circulatory insufficiency. Ammonia level in the blood of those with chronic pulmocardiac syndrome but without circulatory insufficiency was normal. These studies indicate that the increase of ammonia concentration in venous blood in chronic pulmocardiac syndrome results from disturbance in hepatic cell function, intensified during circulatory insufficiency.

  9. Cocaine and metabolite concentrations in DBS and venous blood after controlled intravenous cocaine administration

    PubMed Central

    Ellefsen, Kayla N; da Costa, Jose Luiz; Concheiro, Marta; Anizan, Sebastien; Barnes, Allan J; Pirard, Sandrine; Gorelick, David A; Huestis, Marilyn A

    2015-01-01

    Background: DBS are an increasingly common clinical matrix. Methods & results: Sensitive and specific methods for DBS and venous blood cocaine and metabolite detection by LC–HRMS and 2D GC–MS, respectively, were validated to examine correlation between concentrations following controlled intravenous cocaine administration. Linear ranges from 1 to 200 µg/l were achieved, with acceptable bias and imprecision. Authentic matched specimens’ (392 DBS, 97 venous blood) cocaine and benzoylecgonine concentrations were qualitatively similar, but DBS had much greater variability (21.4–105.9 %CV) and were lower than in blood. Conclusion: DBS offer advantages for monitoring cocaine intake; however, differences between capillary and venous blood and DBS concentration variability must be addressed. PMID:26327184

  10. Venous blood provides lower GLP-1 concentrations than arterialised blood in the postprandial, but not fasted state: Consequences of sampling methods.

    PubMed

    Chen, Yung-Chih; Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Walhin, Jean-Philippe; Betts, James A; Thompson, Dylan; Gonzalez, Javier T

    2018-06-27

    What is the central question of this study? Glucagon-like peptide-1 (GLP-1) is an important obesity/diabetes target, with effects dependent on circulating GLP-1 concentrations. Peripheral tissues extract GLP-1, therefore sampling venous versus arterialised blood may provide different GLP-1 concentrations. This study examined whether arterialisation alters GLP-1 concentrations during fasting and feeding. What is the main finding and its importance? This study demonstrates that venous blood provides lower postprandial, but not fasting, GLP-1 concentrations versus arterialised blood. Therefore, when accurate assessment of postprandial peripheral availability of GLP-1 is required, blood sampling methods should be carefully considered, clearly reported, and arterialisation is recommended. Glucagon-like peptide-1 (GLP-1) displays concentration-dependent effects on metabolism, appetite and angiogenesis, so accurate determination of circulating GLP-1 concentrations is important. This study compared GLP-1 concentrations in venous versus arterialised blood under both fasted and fed conditions. Venous and arterialised blood samples were simultaneously drawn from ten, young, healthy men before, and 30, 60 and 120 min after, ingestion of 75 g glucose. Plasma GLP-1 concentrations increased in response to glucose ingestion (time effect: p < 0.01) and to a lesser extend in venous versus arterialised plasma (time x arterialisation interaction: p < 0.01). Accordingly, the plasma incremental area under the curve was lower in venous versus arterialised plasma (974 ± 88 versus 1214 ± 115 pmol·L x 120 min -1 , respectively, p = 0.049). In the postprandial state, there was a positive relationship between arterialised GLP-1 concentrations and the venous-arterialised difference in GLP-1 concentrations (r 2  = 0.51; p < 0.01). Both arterialised and venous peak GLP-1 concentrations showed positive relationships with peak arterialised insulin concentrations (both r 2

  11. Agreement of arterial sodium and arterial potassium levels with venous sodium and venous potassium in patients admitted to intensive care unit.

    PubMed

    Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha

    2015-02-01

    Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.

  12. [Concordance between central venous and arterial blood gases in post-surgical myocardial revascularization patients in stable condition].

    PubMed

    Santos-Martínez, Luis Efren; Guevara-Carrasco, Marlene; Naranjo-Ricoy, Guillermo; Baranda-Tovar, Francisco Martín; Moreno-Ruíz, Luis Antonio; Herrera-Velázquez, Marco Antonio; Magaña-Serrano, José Antonio; Valencia-Sánchez, Jesús Salvador; Calderón-Abbo, Moisés Cutiel

    2014-01-01

    The concordance between the parameters of arterial and central venous blood gases has not been defined yet. We studied the concordance between both parameters in post-surgical myocardial revascularization patients in stable condition. Consecutive subjects were studied in a cross-sectional design. The position of the central venous catheter was performed and simultaneously we obtained arterial and central venous blood samples prior to discharge from the intensive care unit. Data are expressed according to Bland-Altman statistical method and the intraclass correlation coefficient. Statistical result was accepted at P<.05. Two hundred and six samples were studied of 103 post-surgical patients, pH and lactate had a mean difference (limits of agreement) 0.029±0.048 (-0018, 0.077) and -0.12±0.22 (-0.57, 0.33) respectively. The magnitude of the intraclass correlation coefficient was 0.904 and 0.943 respectively. The values related to oxygen pressure were 27.86±6.08 (15.9, 39.8) and oxygen saturation 33.02±6.13 (21, 45), with magnitude of 0.258 and 0.418 respectively. The best matching parameters between arterial and central venous blood samples were pH and lactate. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  13. Prior exercise alters the difference between arterialised and venous glycaemia: implications for blood sampling procedures.

    PubMed

    Edinburgh, Robert M; Hengist, Aaron; Smith, Harry A; Betts, James A; Thompson, Dylan; Walhin, Jean-Philippe; Gonzalez, Javier T

    2017-05-01

    Oral glucose tolerance and insulin sensitivity are common measures, but are determined using various blood sampling methods, employed under many different experimental conditions. This study established whether measures of oral glucose tolerance and oral glucose-derived insulin sensitivity (insulin sensitivity indices; ISI) differ when calculated from venous v. arterialised blood. Critically, we also established whether any differences between sampling methods are consistent across distinct metabolic conditions (after rest v. after exercise). A total of ten healthy men completed two trials in a randomised order, each consisting of a 120-min oral glucose tolerance test (OGTT), either at rest or post-exercise. Blood was sampled simultaneously from a heated hand (arterialised) and an antecubital vein of the contralateral arm (venous). Under both conditions, glucose time-averaged AUC was greater from arterialised compared with venous plasma but importantly, this difference was larger after rest relative to after exercise (0·99 (sd 0·46) v. 0·56 (sd 0·24) mmol/l, respectively; P<0·01). OGTT-derived ISIMatsuda and ISICederholm were lower when calculated from arterialised relative to venous plasma and the arterialised-venous difference was greater after rest v. after exercise (ISIMatsuda: 1·97 (sd 0·81) v. 1·35 (sd 0·57) arbitrary units (au), respectively; ISICederholm : 14·76 (sd 7·83) v. 8·70 (sd 3·95) au, respectively; both P<0·01). Venous blood provides lower postprandial glucose concentrations and higher estimates of insulin sensitivity, compared with arterialised blood. Most importantly, these differences between blood sampling methods are not consistent after rest v. post-exercise, preventing standardised venous-to-arterialised corrections from being readily applied.

  14. Vasopressin-induced changes in splanchnic blood flow and hepatic and portal venous pressures in liver resection.

    PubMed

    Bown, L Sand; Ricksten, S-E; Houltz, E; Einarsson, H; Söndergaard, S; Rizell, M; Lundin, S

    2016-05-01

    To minimize blood loss during hepatic surgery, various methods are used to reduce pressure and flow within the hepato-splanchnic circulation. In this study, the effect of low- to moderate doses of vasopressin, a potent splanchnic vasoconstrictor, on changes in portal and hepatic venous pressures and splanchnic and hepato-splanchnic blood flows were assessed in elective liver resection surgery. Twelve patients were studied. Cardiac output (CO), stroke volume (SV), mean arterial (MAP), central venous (CVP), portal venous (PVP) and hepatic venous pressures (HVP) were measured, intraoperatively, at baseline and during vasopressin infusion at two infusion rates (2.4 and 4.8 U/h). From arterial and venous blood gases, the portal (splanchnic) and hepato-splanchnic blood flow changes were calculated, using Fick's equation. CO, SV, MAP and CVP increased slightly, but significantly, while systemic vascular resistance and heart rate remained unchanged at the highest infusion rate of vasopressin. PVP was not affected by vasopressin, while HVP increased slightly. Vasopressin infusion at 2.4 and 4.8 U/h reduced portal blood flow (-26% and -37%, respectively) and to a lesser extent hepato-splanchnic blood flow (-9% and -14%, respectively). The arterial-portal vein lactate gradient was not significantly affected by vasopressin. Postoperative serum creatinine was not affected by vasopressin. Short-term low to moderate infusion rates of vasopressin induced a splanchnic vasoconstriction without metabolic signs of splanchnic hypoperfusion or subsequent renal impairment. Vasopressin caused a centralization of blood volume and increased cardiac output. Vasopressin does not lower portal or hepatic venous pressures in this clinical setting. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. ABO blood groups and risk of deep venous thromboembolism in Chinese Han population from Chaoshan region in South China.

    PubMed

    Yu, Min; Wang, Cantian; Chen, Tingting; Hu, Shuang; Yi, Kaihong; Tan, Xuerui

    2017-04-01

     Objectives: To demonstrate the prevalence of ABO blood groups with deep venous thromboembolism in Chinese Han population. A retrospective study was conducted between January 2010 and March 2015 in The First Affiliated Hospital of Shantou University Medical College in Chaoshan District of Guangdong Province in South China. Eighty nine patients with confirmed diagnosis of deep venous thromboembolism were included. Frequency of blood groups was determined. Results: Of 89 patients with deep venous thromboembolism, 28 patients had blood group A (31.5%), 28 patients had blood group B (31.5%), 13 patients had blood group AB (14.6%), and 20 patients had blood group O (22.5%). Compared with O blood type, the odds ratios of deep venous thromboembolism for A, B and AB were 2.23 (95% CI, 1.27-3.91), 2.34 (95% CI, 1.34-4.09) and  4.43 (95% CI, 2.24-8.76). Conclusion: There is a higher risk of venous thromboembolism in non-O blood groups than O group.

  16. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study.

    PubMed

    Neufeld, Lynnette; García-Guerra, Armando; Sánchez-Francia, Domingo; Newton-Sánchez, Oscar; Ramírez-Villalobos, María Dolores; Rivera-Dommarco, Juan

    2002-01-01

    To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Capillary blood had higher Hb (+0.5 g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3 g/dl). Specificity to detect anemia was adequate (> 0.90) but sensitivity was low for capillary blood assessed by Hemocue (< 0.80). The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies. The English version of this paper is available too at: http://www.insp.mx/salud/index.html.

  17. Measurement of Venous Blood Flow in the Lower Limbs: Prevention of Deep Vein Thrombosis during Prolonged Sitting

    DTIC Science & Technology

    2004-06-01

    Abstract. The venous blood flow during stretching and deep breathing in the sitting posture was examined in the present study. First, an...increase in the venous return. Therefore, we suggest that stretching and deep breathing can be used sometimes as preventive measures for deep vein...thrombosis during prolonged sitting. Keywords. Venous blood flow, Near infrared spectroscopy, Deep vein thrombosis. 1. Introduction It has been

  18. Cerebral venous blood oxygenation monitoring during hyperventilation in healthy volunteers with a novel optoacoustic system

    NASA Astrophysics Data System (ADS)

    Petrov, Andrey; Prough, Donald S.; Petrov, Irene Y.; Petrov, Yuriy; Deyo, Donald J.; Henkel, Sheryl N.; Seeton, Roger; Esenaliev, Rinat O.

    2013-03-01

    Monitoring of cerebral venous oxygenation is useful to facilitate management of patients with severe or moderate traumatic brain injury (TBI). Prompt recognition of low cerebral venous oxygenation is a key to avoiding secondary brain injury associated with brain hypoxia. In specialized clinical research centers, jugular venous bulb catheters have been used for cerebral venous oxygenation monitoring and have demonstrated that oxygen saturation < 50% (normal range is 55-75%) correlates with poor clinical outcome. We developed an optoacoustic technique for noninvasive monitoring of cerebral venous oxygenation. Recently, we designed and built a novel, medical grade optoacoustic system operating in the near-infrared spectral range for continuous, real-time oxygenation monitoring in the superior sagittal sinus (SSS), a large central cerebral vein. In this work, we designed and built a novel SSS optoacoustic probe and developed a new algorithm for SSS oxygenation measurement. The SSS signals were measured in healthy volunteers during voluntary hyperventilation, which induced changes in SSS oxygenation. Simultaneously, we measured exhaled carbon dioxide concentration (EtCO2) using capnography. Good temporal correlation between decreases in optoacoustically measured SSS oxygenation and decreases in EtCO2 was obtained. Decreases in EtCO2 from normal values (35-45 mmHg) to 20-25 mmHg resulted in SSS oxygenation decreases by 3-10%. Intersubject variability of the responses may relate to nonspecific brain activation associated with voluntary hyperventilation. The obtained data demonstrate the capability of the optoacoustic system to detect in real time minor changes in the SSS blood oxygenation.

  19. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    PubMed

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Blood flow vs. venous pressure effects on filtration coefficient in oleic acid-injured lung.

    PubMed

    Anglade, D; Corboz, M; Menaouar, A; Parker, J C; Sanou, S; Bayat, S; Benchetrit, G; Grimbert, F A

    1998-03-01

    On the basis of changes in capillary filtration coefficient (Kfc) in 24 rabbit lungs, we determined whether elevations in pulmonary venous pressure (Ppv) or blood flow (BF) produced differences in filtration surface area in oleic acid-injured (OA) or control (Con) lungs. Lungs were cyclically ventilated and perfused under zone 3 conditions by using blood and 5% albumin with no pharmacological modulation of vascular tone. Pulmonary arterial, venous, and capillary pressures were measured by using arterial, venous, and double occlusion. Before and during each Kfc-measurement maneuver, microvascular/total vascular compliance was measured by using venous occlusion. Kfc was measured before and 30 min after injury, by using a Ppv elevation of 7 cmH2O or a BF elevation from 1 to 2 l . min-1 . 100 g-1 to obtain a similar double occlusion pressure. Pulmonary arterial pressure increased more with BF than with Ppv in both Con and OA lungs [29 +/- 2 vs. 19 +/- 0.7 (means +/- SE) cmH2O; P < 0. 001]. In OA lungs compared with Con lungs, values of Kfc (200 +/- 40 vs. 83 +/- 14%, respectively; P < 0.01) and microvascular/total vascular compliance ratio (86 +/- 4 vs. 68 +/- 5%, respectively; P < 0.01) increased more with BF than with Ppv. In conclusion, for a given OA-induced increase in hydraulic conductivity, BF elevation increased filtration surface area more than did Ppv elevation. The steep pulmonary pressure profile induced by increased BF could result in the recruitment of injured capillaries and could also shift downstream the compression point of blind (zone 1) and open injured vessels (zone 2).

  1. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    PubMed

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P < 0.001], with parallel changes in QPA Neither PEEP nor volume state altered RVR (P = 0.489). MSFPinsp_hold overestimated MSFPRAO [16.5 (SD 5.8) vs. 13.6 (SD 3.2) mmHg, P = 0.001; mean difference 3.0 (SD 5.1) mmHg]. Inspiratory holds shifted the RAP/QPA relationship rightward in euvolemia because inferior vena cava flow (QIVC) recovered early after an inspiratory hold nadir. The QIVC nadir was lowest after bleeding [36% (SD 24%) of preinspiratory hold at 15 cmH2O inspiratory pressure], and the QIVC recovery was most complete at the lowest inspiratory pressures independent of volume state [range from 80% (SD 7%) after bleeding to 103% (SD 8%) at PEEP 10 cmH2O of QIVC before inspiratory hold]. The QIVC recovery thus defends venous return, possibly via hepatosplanchnic vascular waterfall. Copyright © 2016 the American Physiological Society.

  2. Metabolism of 14C-dehydroepiandrosterone in female adipose tissue and venous blood.

    PubMed

    Schindler, A E; Aymar, M

    1975-09-01

    The metabolism of dehydroepiandrosterone in female adipose tissue and venous blood in 11 patients was studied by a double isotope method which is described in detail. The main metabolite isolated, identified and quantitated was androstenediol. The conversion rate of dehydroepiandrosterone to androstenediol for adipose tissue ranged between 3.32-14.28% (X = 7.47 +/- 3.34 SD) and for venous blood between 2.88-9.60% (X = 5.84 +/- 1.80 SD). The values found for androstenedione and testostrone did not differ from the control experiments. Oestrone and oestradiol could not be detected. The contribution of the peripheral steroid metabolism to the pool of androgenic steroids is discussed.

  3. Retinal venous blood carbon monoxide response to bright light in male pigs: A preliminary study.

    PubMed

    Oren, Dan A; Duda, Magdalena; Kozioł, Katarzyna; Romerowicz-Misielak, Maria; Koziorowska, Anna; Sołek, Przemysław; Nowak, Sławomir; Kulpa, Magdalena; Koziorowski, Marek

    2017-03-01

    The physical mechanism by which light is absorbed in the eye and has antidepressant and energizing effects in Seasonal Affective Disorder and other forms of psychiatric major depression is of scientific interest. This study was designed to explore one specific aspect of a proposed humoral phototransduction mechanism, namely that carbon monoxide (CO) levels increase in retinal venous blood in response to bright light. Eleven mature male pigs approximately six months of age were kept for 7days in darkness and fasted for 12h prior to surgery. Following mild sedation, anesthesia was induced. Silastic catheters were inserted into the dorsal nasal vein through the angular vein of the eye to reach the ophthalmic sinus, from which venous blood outflowing from the eye area was collected. The animals were exposed to 5000lx of fluorescent-generated white light. CO levels in the blood were analyzed by gas chromatography before and after 80min of light exposure. At baseline, mean CO levels in the retinal venous blood were 0.43±0.05(SE)nmol/ml. After bright light, mean CO levels increased to 0.54±0.06nmol/ml (two-tailed t-test p<0.05). This study provides preliminary mammalian evidence that acute bright light exposure raises carbon monoxide levels in ophthalmic venous blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Venous Shunt Versus Venous Ligation for Vascular Damage Control: The Immunohistochemical Evidence.

    PubMed

    Góes Junior, Adenauer Marinho de Oliveira; Abib, Simone de Campos Vieira; Alves, Maria Teresa de Seixas; Ferreira, Paulo Sérgio Venerando da Silva; Andrade, Mariseth Carvalho de

    2017-05-01

    To evaluate the expression of immunohistochemical markers of tissue ischemia (iNOS, eNOS, and HSP70) in a vascular damage control experimental model to determine if a venous temporary vascular shunt insertion leads to a better limb perfusion when compared with the ligature of the injured vein. Experimental study in male Sus Scrofa weighting 40 Kg. Animals were distributed into 5 groups: group 1 animals were submitted to right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2 animals were submitted to right EIA shunting and right EIV shunting; group 3 animals were submitted to right EIV ligation; group 4 animals were submitted to right EIV shunting; group 5 animals were not submitted to vascular shunting or venous ligation. Transonic Systems flowmeters were used to measure vascular flow on right and left external iliac vessels, and i-STAT (Abbot) portable blood analyzer was used for EIVs blood biochemical analysis. An initial baseline register of invasive arterial pressure, iliac vessels flow, and venous blood analysis was performed. Arterial pressure and iliac vessels flow were taken immediately after right iliac vessels shunting or ligation. Then, hemorrhagic shock was induced by continuous 20 mL/min blood withdraw from the external right jugular vein whereas arterial blood pressure and iliac vessels flow registers were taken every 10 min, and blood samples from EIVs were obtained every 30 min until the vascular flow through right EIA (or through the shunt inserted into the right EIV for group 4 animals) became inexistent or until the animal's death. After the end of the experiments, bilateral hind limb's biopsies were obtained for immunohistochemical analysis. Using image editing and analysis software, the expression of iNOS, eNOS, and HSP70 (3 well-known ischemic associated immunohistochemical markers) was assessed. The mean expression of each marker in the right hind limb was compared between groups. For statistical

  5. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    ERIC Educational Resources Information Center

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  6. The gaseous messenger carbon monoxide is released from the eye into the ophthalmic venous blood depending on the intensity of sunlight.

    PubMed

    Koziorowski, M; Stefańczyk-Krzymowska, S; Tabecka-Lonczyńska, A; Gilun, P; Kamiński, M

    2012-01-01

    Circadian and seasonal rhythms in daylight affect many physiological processes. In the eye, energy of intense visible light not only initiates a well-studied neural reaction in the retina that modulates the secretory function of the hypothalamus and pineal gland, but also activates the heme oxygenase (HO) to produce carbon monoxide (CO). This study was designed to determine whether the concentration of carbon monoxide (CO) in the ophthalmic venous blood changes depending on the phase of the day and differing extremely light intensity seasons: summer and winter. The concentration of CO in the venous blood flowing out from the nasal cavity, where heme oxygenase (HO) is expressed, but no photoreceptors, was used as a control. Sixteen mature males of a wild boar and pig crossbreed were used for this study. Samples of ophthalmic and nasal venous blood and systemic arterial and venous blood were collected repeatedly for two consecutive days during the longest days of the summer and the shortest days of the winter. The concentrations of CO in blood samples was measured using a standard addition method. During the longest days of the summer the concentration of CO in ophthalmic venous blood averaged 3.32 ± 0.71 and 3.43 ± 0.8 nmol/ml in the morning and afternoon, respectively, and was significantly higher than in the night averaging 0.89 ± 0.12 nmol/ml (p<0.001). During the shortest day of the winter CO concentration in ophthalmic venous blood was 1.11 ± 0.10 and 1.13 ± 0.14 nmol/ml during the light and nocturnal phase, respectively, and did not differ between phases, but was lower than in the light phase of the summer (p<0.01). The CO concentration in the control nasal venous blood did not differ between seasons and day phases and was lower than in ophthalmic venous blood during the summer (p<0.01) and winter (p<0.05). The results indicate that the gaseous messenger carbon monoxide is released from the eye into the ophthalmic venous blood depending on the intensity

  7. [Correlation between arterial and venous blood gas analysis parameters in patients with acute exacerbation of chronic obstructive pulmonary disease].

    PubMed

    Novović, Miloš; Topić, Vesna

    2012-01-01

    Arterial blood gas (ABG) analyses have an important role in the assessment and monitoring of the metabolic and oxygen status of patients with acute exacerbation of chronic obstructive pulmonary disease (COPD). Arterial puncture could have a lot of adverse effects, while sampling of venous blood is simpler and is not so invasive. The aim of this study was to evaluate whether venous blood gas (VBG) values of pH, partial pressure of carbon dioxide (PCO2), partial oxygen pressure (PO2), bicarbonate (HCO3), and venous and arterial blood oxygen saturation (SO2) can reliably predict ABG levels in patients with acute exacerbation of COPD. Forty-seven patients with a prior diagnosis of COPD were included in this prospective study. The patients with acute exacerbation of this disease were examined at the General Hospital EMS Department in Prijepolje. ABG samples were taken immediately after venous sampling, and both were analyzed. The Pearson correlation coefficients between arterial and venous parameters were 0.828, 0.877, 0.599, 0.896 and 0.312 for pH, PCO2, PO2, HCO3 and SO2, respectively. The statistically significant correlation between arterial and venous pH, PCO2 and HCO3, values was found in patients with acute exacerbation of COPD (p<0.001). When we cannot provide arterial blood for analysis, venous values of the pH, Pv,CO2 and HCO3 parameters can be an alternative to their arterial equivalents in the interpretation of the metabolic status in patients with acute exacerbation of COPD, while the values of venous Pv,O, and Sv,O2 cannot be used as predictors in the assessment of oxygen status of such patients.

  8. A new method for noninvasive venous blood oxygen detection.

    PubMed

    Zhang, Xu; Zhang, Meimei; Zheng, Shengkun; Wang, Liqi; Ye, Jilun

    2016-07-19

    Blood oxygen saturation of vein (SvO2) is an important clinical parameter for patient monitoring. However, the existing clinical methods are invasive, expensive, which are also painful for patients. Based on light-absorption, this study describes a new noninvasive SvO2 measurement method by using external stimulation signal to generate cyclical fluctuation signal in the vein, which overcomes the low signal-to-noise ratio problem in the measurement process. In this way, the value of SvO2 can be obtained continuously in real time. The experimental results demonstrate that the method can successfully measure venous oxygen saturation by artificial addition of stimulation. Under hypoxic conditions, the system can reflect the overall decline of venous oxygen saturation better. When the results measured by the new method are compared with those measured by the invasive method, the root mean square error of the difference is 5.31 and the correlation coefficient of the difference is 0.72. The new method can be used to measure SvO2 and evaluate body oxygen consumption, and its accuracy needs improvement. Real-time and continuous monitoring can be achieved by replacing invasive method with noninvasive method, which provides more comprehensive clinical information in a timely manner and better meet the needs of clinical treatment. However, the accuracy of the new noninvasive SvO2 measurement based on light-absorption has to be further improved.

  9. Automated artery-venous classification of retinal blood vessels based on structural mapping method

    NASA Astrophysics Data System (ADS)

    Joshi, Vinayak S.; Garvin, Mona K.; Reinhardt, Joseph M.; Abramoff, Michael D.

    2012-03-01

    Retinal blood vessels show morphologic modifications in response to various retinopathies. However, the specific responses exhibited by arteries and veins may provide a precise diagnostic information, i.e., a diabetic retinopathy may be detected more accurately with the venous dilatation instead of average vessel dilatation. In order to analyze the vessel type specific morphologic modifications, the classification of a vessel network into arteries and veins is required. We previously described a method for identification and separation of retinal vessel trees; i.e. structural mapping. Therefore, we propose the artery-venous classification based on structural mapping and identification of color properties prominent to the vessel types. The mean and standard deviation of each of green channel intensity and hue channel intensity are analyzed in a region of interest around each centerline pixel of a vessel. Using the vector of color properties extracted from each centerline pixel, it is classified into one of the two clusters (artery and vein), obtained by the fuzzy-C-means clustering. According to the proportion of clustered centerline pixels in a particular vessel, and utilizing the artery-venous crossing property of retinal vessels, each vessel is assigned a label of an artery or a vein. The classification results are compared with the manually annotated ground truth (gold standard). We applied the proposed method to a dataset of 15 retinal color fundus images resulting in an accuracy of 88.28% correctly classified vessel pixels. The automated classification results match well with the gold standard suggesting its potential in artery-venous classification and the respective morphology analysis.

  10. Comparison of oxidative/antioxidative status of penile corpus cavernosum blood and peripheral venous blood.

    PubMed

    Yeni, E; Gulum, M; Selek, S; Erel, O; Unal, D; Verit, A; Savas, M

    2005-01-01

    The aim of the study is to determine and to compare the oxidative and antioxidative status of penile corpus cavernosum and peripheral venous blood. A total of 28 adult healthy males were included in the study. Whole blood was simultaneously withdrawn from penile corpus cavernosum and the cubital vein and their plasma separated. Total antioxidant capacity (TAC), vitamin C, total protein, albumin, uric acid, bilirubin and total peroxide (TP) levels of both plasma samples were measured and compared. While TAC, total protein, albumin, bilirubin and uric acid levels were higher, vitamin C levels were lower in cavernosal blood than that of peripheral blood. On the other hand, TP level was found to be higher in penile blood samples than that of peripheral blood. We thought that the normal erectile process of the penile cavernosal body leads to increased production of oxidants as in the mechanism of ischaemia-reperfusion; however, the increase of TAC can prevent development of oxidative injury.

  11. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    PubMed

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an

  12. The complicated role of venous drainage on the survival of arterialized venous flaps

    PubMed Central

    Weng, Weidong; Zhang, Feng; Zhao, Bin; Wu, Zhipeng; Gao, Weiyang; Li, Zhijie; Yan, Hede

    2017-01-01

    The arterialized venous flap (AVF) has been gradually popularized in clinical settings; however, its survival is still inconsistent and the role of venous drainage remains elusive. In this study, we aimed to investigate the role of venous drainage on the flap survival of arterialized venous flaps. An arterialized venous flap was outlined symmetrically in the rabbit abdomen. The arterial perfusion flap with a unilateral vascular pedicle was taken as the control group and three other experimental groups (I, II and III) were designed based on the number of drainage veins (n = 1, 2 and 3 in the three groups, respectively). Compared with the control group, significant venous congestion was noted in all the experimental groups and the most severe one was seen in group I; while no statistical difference was observed between groups II and III. Similar results regarding blood perfusion state, epidermal metabolite levels and flap survival status were obtained among the three groups. These findings suggested that venous drainage is vital in the survival of the flap, but unlike in the arterial perfusion flaps, the problem of venous congestion can only be partially solved by increasing the number of draining veins. Further studies are warranted to gain insight into this complicated issue. PMID:28145882

  13. Measurement of central venous pressure and determination of hormones in blood serum during weightlessness

    NASA Technical Reports Server (NTRS)

    Kirsch, K.

    1981-01-01

    A Spacelab experiment is described which proposes to obtain data on the degree of engorgement of the cephalad circulation during weightlessness by recording central venous pressure. Of practical importance is the question of how close the astronauts are to pulmonary edema and whether the pressure falls toward normal during the time of the mission. Another experiment to investigate deviations from normal fluid and mineral metabolism, possibly initiated by the central engorgement of the low pressure system, is discussed. Hormones responsible for the control of water and mineral balance (vasopressin, catecholamines, renin, aldosterone, corticosteroids, and prostaglandin E1) will be analyzed from blood samples.

  14. Peripheral venous vs. capillary microfilariaemia in a dog co-infected with Dirofilaria repens and D. immitis: A comparative approach using triatomine bugs for blood collection.

    PubMed

    Păstrav, Ioana Raluca; Ionică, Angela Monica; Peştean, Cosmin; Novakova, Eva; Modrý, David; Mihalca, Andrei Daniel

    2018-06-15

    Dirofilaria immitis and D. repens are mosquito-borne nematodes, primarily infecting dogs, but also other species of carnivores and even humans. Given their impact on animal and human health, the transmission of these filarioids has been widely studied. The microfilariaemia has been shown to have a circadian variation for both Dirofilaria species infecting dogs. Due to methodological difficulties, the periodicity was only studied using venous blood samples, while the mosquitoes feed, in fact, on capillary blood. In this context, the present study aimed to test the feasibility of using triatomine bugs for the collection of capillary blood and to comparatively evaluate the level of microfilariaemia and its circadian variation in capillary blood vs. peripheral venous blood in a dog naturally co-infected with D. immitis and D. repens. The results showed a feeding success of 50%, with variations in the blood meal volume that the bugs ingested. The relative values of microfilariaemia (mf/bug) were strongly correlated with the volume of blood recovered: the more blood recovered from each bug, the higher values of microfilariaemia in the evening samples while the opposite results were obtained for the morning samples. The counting of microfilariae revealed a dominance of D. immitis in all the samples, but with significantly higher microfilariaemia in the venous blood. Meanwhile, for D. repens, the situation was opposite, with higher counts in the capillary blood samples. Our study showed that triatomine bugs can be used as a model for the collection and study of microfilariaemia in the capillary blood in mammals. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Non-contact imaging of venous compliance in humans using an RGB camera

    NASA Astrophysics Data System (ADS)

    Nakano, Kazuya; Satoh, Ryota; Hoshi, Akira; Matsuda, Ryohei; Suzuki, Hiroyuki; Nishidate, Izumi

    2015-04-01

    We propose a technique for non-contact imaging of venous compliance that uses the red, green, and blue (RGB) camera. Any change in blood concentration is estimated from an RGB image of the skin, and a regression formula is calculated from that change. Venous compliance is obtained from a differential form of the regression formula. In vivo experiments with human subjects confirmed that the proposed method does differentiate the venous compliances among individuals. In addition, the image of venous compliance is obtained by performing the above procedures for each pixel. Thus, we can measure venous compliance without physical contact with sensors and, from the resulting images, observe the spatial distribution of venous compliance, which correlates with the distribution of veins.

  16. Association between delivery methods for red blood cell transfusion and the risk of venous thromboembolism: a longitudinal study.

    PubMed

    Rogers, Mary A M; Blumberg, Neil; Bernstein, Steven J; Flanders, Scott A; Chopra, Vineet

    2016-12-01

    Mechanisms of red blood cell delivery and their contribution to the incidence of venous thromboembolism are not well understood in the clinical setting. We assessed whether red blood cell transfusion through peripherally inserted central catheters (PICCs) affects the risk of venous thromboembolism compared with transfusion through non-PICC devices. We implemented a prospective study between Jan 1, 2013, and Sept 12, 2015, in patients (age ≥18 years) admitted to a general medicine ward or intensive care unit who received a PICC for any reason during clinical care in 47 hospitals in Michigan, USA, with a maximum follow-up of 70 days. The exposure of interest was route of red blood cell transfusion. The primary outcome was symptomatic, radiographically confirmed, deep-vein thrombosis in the arm or leg or pulmonary embolism. We used Cox proportional hazards regression for analyses. Venous thromboembolism developed in 482 (5%) of 10 604 patients with PICCs. Of 788 patients who received a red blood cell transfusion through a multi-lumen PICC, 61 had venous thromboembolism. The adjusted hazard ratio (HR) for venous thromboembolism in all patients whose transfusions were administered through a multi-lumen PICC was 1·96 (95% CI 1·47-2·61; p<0·0001) compared with patients not receiving a transfusion, and was 1·79 (1·09-2·95; p=0·022) compared with patients transfused through a peripheral intravenous line. Compared with delivery through a peripheral intravenous line, venous thromboembolism risk was not elevated if transfusions were delivered through a single-lumen PICC (HR 0·98, 95% CI 0·44-2·14; p=0·95) or central venous catheter (1·50, 0·77-2·91; p=0·23). For every red blood cell unit transfused through a PICC, there was a significantly increased risk of venous thromboembolism (adjusted HR 1·24, 95% CI 1·01-1·52; p=0·037). Patients who received a transfusion through a PICC in the left arm were significantly more likely to develop a deep

  17. Radionuclide plethysmography and Tc-99m red blood cell venography in venous thrombosis: comparison with contrast venography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, I.; Royal, H.D.; Uren, R.F.

    1984-01-01

    Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. Twenty-one patients with suspected deep venous thrombosis were studied prospectively using RPG, radionuclide venography (RV), and contrast venography (CV) to establish the usefulness of RPG alone and in combination wth RV in the diagnosis of ileofemoral venous thrombosis (sensitivity, 91%; specificity, 100%). RV was lessmore » sensitive (73%) and less specific (93%) in diagnosing that condition.« less

  18. Venous drainage of the face.

    PubMed

    Onishi, S; Imanishi, N; Yoshimura, Y; Inoue, Y; Sakamoto, Y; Chang, H; Okumoto, T

    2017-04-01

    The venous anatomy of the face was examined in 12 fresh cadavers. Venograms and arteriovenograms were obtained after the injection of contrast medium. In 8 of the 12 cadavers, a large loop was formed by the facial vein, the supratrochlear vein, and the superficial temporal vein, which became the main trunk vein of the face. In 4 of the 12 cadavers, the superior lateral limb of the loop vein was less well developed. The loop vein generally did not accompany the arteries of the face. Cutaneous branches of the loop vein formed a polygonal venous network in the skin, while communicating branches ran toward deep veins. These findings suggest that blood from the dermis of the face is collected by the polygonal venous network and enters the loop vein through the cutaneous branches, after which blood flows away from the face through the superficial temporal vein, the facial vein, and the communicating branches and enters the deep veins. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Limb venous compliance responses to lower body negative pressure in humans with high blood pressure.

    PubMed

    Goulopoulou, S; Deruisseau, K C; Carhart, R; Kanaley, J A

    2012-05-01

    This study tested the hypothesis that limb venous responses to baroreceptor unloading are altered in individuals with high blood pressure (HBP) compared with normotensive (NT) controls. Calf venous compliance was assessed in 20 subjects with prehypertension and stage-1 hypertension (mean arterial pressure, MAP: 104±1 mm Hg) and 13 NT controls (MAP: 86±2 mm Hg) at baseline and during lower body negative pressure (LBNP), using venous occlusion plethysmography. Baroreflex sensitivity (BRS) was measured using the sequence technique and total peripheral resistance (TPR) was estimated from finger plethysmography. Baseline venous compliance was not different between groups, but the HBP group had lower baseline lnBRS (2.22±0.14 vs 2.7±0.18 ms mm Hg(-1)) and greater baseline TPR (3828±138 vs 3250±111 dyn sec(-1) cm(-5) m(2), P<0.05). Calf venous compliance was reduced in response to LBNP only in the NT group (P<0.05). The HBP group had a greater increase in TPR (ΔTPR) compared with the NT group (+1649±335 vs +718±196 dyn sec(-1) cm(-5) m(2), P<0.05). In conclusion, the early stages of hypertension are characterized by an attenuated venoconstrictor response to baroreceptor unloading, which may compensate for an exaggerated vasoconstrictor response and protect against further increases in blood pressure.

  20. Blood pressure normalization post-jugular venous balloon angioplasty.

    PubMed

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  1. Comparison of ethanol concentrations in venous blood and end-expired breath during a controlled drinking study.

    PubMed

    Jones, A W; Andersson, L

    2003-03-12

    Concentration-time profiles of ethanol were determined for venous whole blood and end-expired breath during a controlled drinking experiment in which healthy men (n=9) and women (n=9) drank 0.40-0.65 g ethanol per kg body weight in 20-30 min. Specimens of blood and breath were obtained for analysis of ethanol starting at 50-60 min post-dosing and then every 30-60 min for 3-6 h. This protocol furnished 130 blood-breath pairs for statistical evaluation. Blood-ethanol concentration (BAC, mg/g) was determined by headspace gas chromatography and breath-ethanol concentration (BrAC, mg/2l) was determined with a quantitative infrared analyzer (Intoxilyzer 5000S), which is the instrument currently used in Sweden for legal purposes. In 18 instances the Intoxilyzer 5000S gave readings of 0.00 mg/2l whereas the actual BAC was 0.08 mg/g on average (range 0.04-0.15 mg/g). The remaining 112 blood- and breath-alcohol measurements were highly correlated (r=0.97) and the regression relationship was BAC=0.10+0.91BrAC and the residual standard deviation (S.D.) was 0.042 mg/g (8.4%). The slope (0.91+/-0.0217) differed significantly from unity being 9% low and the intercept (0.10+/-0.0101) deviated from zero (t=10.2, P<0.001), indicating the presence of both proportional and constant bias, respectively. The mean bias (BAC - BrAC) was 0.068 mg/g and the 95% limits of agreement were -0.021 and 0.156 mg/g. The average BAC/BrAC ratio was 2448+/-540 (+/-S.D.) with a median of 2351 and 2.5th and 97.5th percentiles of 1836 and 4082. We found no significant gender-related differences in BAC/BrAC ratios, being 2553+/-576 for men and 2417+/-494 for women (t=1.34, P>0.05). The mean rate of ethanol disappearance from blood was 0.157+/-0.021 mg/(g per hour), which was very close to the elimination rate from breath of 0.161+/-0.021 mg/(2l per hour) (P>0.05). Breath-test results obtained with Intoxilyzer 5000S (mg/2l) were generally less than the coexisting concentrations of ethanol in venous blood

  2. A comparison of capillary and venous blood haematocrits of pregnant women in Nigeria: the impact on diagnosis and prevalence of anaemia in pregnancy.

    PubMed

    Dim, Cyril Chukwudi; Ugwu, Emmanuel Onyebuchi; Anyaehie, Ugochukwu Bond; Obioha, Kingsley Chukwu

    2014-01-01

    Volume of red cells in capillary blood varies from that of venous blood. The magnitude of this variation as well as its impact on the diagnosis of anaemia in pregnancy needs to be studied. This study demonstrates the disparity between capillary and venous PCV in pregnancy. To determine whether capillary blood PCV (cPCV) differed from venous blood PCV (vPCV) of normal pregnant women in Enugu, Nigeria, and its effect on diagnosis and prevalence of anaemia. PCV was estimated using pairs of venous and capillary blood samples from 200 consecutive pregnant women at the Antenatal Clinic of University of Nigeria Teaching Hospital, Enugu, Nigeria. Participants' cPCV (median = 34.0%, IQR = 31.0-35.8) was significantly lower than their vPCV (median = 34.0%, IQR = 32.0-37.0) (Z = -6.85, P < 0.001). However, women's cPCV had strong positive correlation with their vPCV (r = 0.883, P < 0.001). The prevalence of anaemia among participants using capillary and venous blood was 33.5% (67/200) and 28.0% (56/200), respectively (O.R = 1.3 (CI 95%: 0.85, 1.98),  P = 0.233). Capillary blood PCV was lower than vPCV among pregnant women in Enugu, Nigeria. Nevertheless, the prevalence of anaemia derived from cPCV did not differ significantly from that of vPCV.

  3. Effect of hand-arm exercise on venous blood constituents during leg exercise

    NASA Technical Reports Server (NTRS)

    Wong, N.; Silver, J. E.; Greenawalt, S.; Kravik, S. E.; Geelen, G.

    1985-01-01

    Contributions by ancillary hand and arm actions to the changes in blood constituents effected by leg exercises on cycle ergometer were assessed. Static or dynamic hand-arm exercises were added to the leg exercise (50 percent VO2 peak)-only control regimens for the subjects (19-27 yr old men) in the two experimental groups. Antecubital venous blood was analyzed at times 0, 15, and 30 min (T0, T15, and T30) for serum Na(+), K(+), osmolality, albumin, total CA(2+), and glucose; blood hemoglobin, hematocrit, and lactic acid; and change in plasma volume. Only glucose and lactate values were affected by additional arm exercise. Glucose decreased 4 percent at T15 and T30 after static exercise, and by 2 percent at T15 (with no change at T30) after dynamic arm exercise. Conversely, lactic acid increased by 20 percent at T30 after static exercise, and by 14 percent by T15 and 6 percent at T30 after dynamic arm exercise. It is concluded that additional arm movements, performed usually when gripping the handle-bar on the cycle ergometer, could introduce significant errors in measured venous concentrations of glucose and lactate in the leg-exercised subjects.

  4. Radionuclide plethysmography and Tc-99m red blood cell venography in venous thrombosis: comparison with contrast venography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, I.; Royal, H.D.; Uren, R.F.

    1984-01-01

    Radionuclide plethysmography (RPG) is a new technique that uses Tc-99m labelled red blood cells to ascertain changes in venous volumes by detecting the change in counts in response to the inflation and deflation of proximal thigh cuffs. Diagnosis of ileofemoral venous occlusion is possible using this technique, which also provides kinetic data of venous outflow. A range of normal values was defined in 19 subjects for per cent change in venous capacitance and venous outflow. Twenty-one patients with suspected deep venous thrombosis were studied prospectively using RPG, radionuclide venography (RV), and contrast venography (CV) to establish the usefulness of RPGmore » alone and in combination with RV in the diagnosis of deep venous thrombosis. RPG proved to be a reliable technique for the diagnosis of ileofemoral venous thrombosis (sensitivity, 91%; specificity, 100%). RV was less sensitive (73%) and less specific (93%) in diagnosing that condition. When RPG is used as the criterion for the detection of ileofemoral vein thrombosis and RV is used as the criterion for the detection of calf vein thrombosis, the combined techniques show improved sensitivity (92%) and specificity (93%) for the detection of all deep venous thromboses.« less

  5. [Injuries to blood vessels near the heart caused by central venous catheters].

    PubMed

    Abram, J; Klocker, J; Innerhofer-Pompernigg, N; Mittermayr, M; Freund, M C; Gravenstein, N; Wenzel, V

    2016-11-01

    Injuries to blood vessels near the heart can quickly become life-threatening and include arterial injuries during central venous puncture, which can lead to hemorrhagic shock. We report 6 patients in whom injury to the subclavian artery and vein led to life-threatening complications. Central venous catheters are associated with a multitude of risks, such as venous thrombosis, air embolism, systemic or local infections, paresthesia, hemothorax, pneumothorax, and cervical hematoma, which are not always immediately discernible. The subclavian catheter is at a somewhat lower risk of catheter-associated sepsis and symptomatic venous thrombosis than approaches via the internal jugular and femoral veins. Indeed, access via the subclavian vein carries a substantial risk of pneumo- and hemothorax. Damage to the subclavian vein or artery can also occur during deliberate and inadvertent punctures and result in life-threatening complications. Therefore, careful consideration of the access route is required in relation to the patient and the clinical situation, to keep the incidence of complications as low as possible. For catheterization of the subclavian vein, puncture of the axillary vein in the infraclavicular fossa is a good alternative, because ultrasound imaging of the target vessel is easier than in the subclavian vein and the puncture can be performed much further from the lung.

  6. To mix or not to mix venous blood samples collected in vacuum tubes?

    PubMed

    Parenmark, Anna; Landberg, Eva

    2011-09-08

    There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

  7. To what extent might deep venous thrombosis and chronic venous insufficiency share a common etiology?

    PubMed

    Malone, P Colm; Agutter, P S

    2009-08-01

    According to the valve cusp hypoxia hypothesis (VCHH), deep venous thrombosis is caused by sustained non-pulsatile (streamline) venous blood flow. This leads to hypoxemia in the valve pockets; hypoxic injury to the inner (parietalis) endothelium of the cusp leaflets activates the elk-1/egr-1 pathway, leading to leukocyte and platelet swarming at the site of injury and, potentially, blood coagulation. Here, we propose an extension of the VCHH to account for chronic venous insufficiency. First, should the foregoing events not proceed to frank thrombogenesis, the valves may nevertheless be chronically injured and become incompetent. Serial incompetence in lower limb valves may then generate ''passive'' venous hypertension. Second, should ostial valve thrombosis obstruct venous return from muscles via tributaries draining into the femoral vein, as Virchow illustrated, ''active'' venous hypertension may supervene: muscle contraction would force the blood in the vessels behind the blocked ostial valves to re-route. Passive or active venous hypertension opposes return flow, leading to luminal hypoxemia and vein wall distension, which in turn may impair vasa venarum perfusion; the resulting mural endothelial hypoxia would lead to leukocyte invasion of the wall and remodelling of the media. We propose that varicose veins result if gross active hypertension stretches the valve ''rings'', rendering attached valves incompetent caudad to obstructed sites, replacing normal centripetal flow in perforating veins with centrifugal flow and over-distending those vessels. We also discuss how hypoxemia-related venous/capillary wall lesions may lead to accumulation of leukocytes, progressive blockage of capillary blood flow, lipodermosclerosis and skin ulceration.

  8. Effect of Vacuum on Venous Drainage: an Experimental Evaluation on Pediatric Venous Cannulas and Tubing Systems.

    PubMed

    Vida, V L; Bhattarai, A; Speggiorin, S; Zanella, F; Stellin, G

    2014-01-01

    To observe how vacuum assisted venous drainage (VAVD) may influence the flow in a cardiopulmonary bypass circuit with different size of venous lines and cannulas. The experimental circuit was assembled to represent the cardiopulmonary bypass circuit routinely used during cardiac surgery. Wall suction was applied directly, modulated and measured into the venous reservoir. The blood flow was measured with a flow-meter positioned on the venous line. The circuit prime volume was replaced with group O date expired re-suspended red cells and Plasmalyte 148 to a hematocrit of 28% to 30%. In an open circuit with gravity siphon venous drain, angled cannulae drain more than straight ones regardless the amount of suction applied to the venous line (16 Fr straight cannula (S) drains 90 ml/min less than a 16 Fr angled (A) with a siphon gravity). The same flow can be obtained with lower cannula size and higher suction (i.e. 12 A with and -30 mmHg). Tables have been created to list how the flow varies according to the size of the cannulas, the size of the venous tubes, and the amount of suction applied to the system. Vacuum assisted venous drainage allows the use of smaller cannulae and venous lines to maintain a good venous return, which is very useful during minimally invasive approaches. The present study should be considered as a preliminary attempt to create a scientific-based starting point for a uniform the use of VAVD.

  9. Low central venous pressure versus acute normovolemic hemodilution versus conventional fluid management for reducing blood loss in radical retropubic prostatectomy: a randomized controlled trial.

    PubMed

    Habib, Ashraf S; Moul, Judd W; Polascik, Thomas J; Robertson, Cary N; Roche, Anthony M; White, William D; Hill, Stephen E; Nosnick, Israel; Gan, Tong J

    2014-05-01

    To compare acute normovolemic hemodilution versus low central venous pressure strategy versus conventional fluid management in reducing intraoperative estimated blood loss, hematocrit drop and need for blood transfusion in patients undergoing radical retropubic prostatectomy under general anesthesia. Patients undergoing radical retropubic prostatectomy under general anesthesia were randomized to conventional fluid management, acute normovolemic hemodilution or low central venous pressure (≤5 mmHg). Treatment effects on estimated blood loss and hematocrit change were tested in multivariable regression models accounting for surgeon, prostate size, and all two-way interactions. Ninety-two patients completed the study. Estimated blood loss (mean ± SD) was significantly lower with low central venous pressure (706 ± 362 ml) compared to acute normovolemic hemodilution (1103 ± 635 ml) and conventional (1051 ± 714 ml) groups (p = 0.0134). There was no difference between the groups in need for blood transfusion, or hematocrit drop from preoperative values. The multivariate model predicting estimated blood loss showed a significant effect of treatment (p = 0.0028) and prostate size (p = 0.0323), accounting for surgeon (p = 0.0013). In the model predicting hematocrit change, accounting for surgeon difference (p = 0.0037), the treatment effect depended on prostate size (p = 0.0007) with the slope of low central venous pressure differing from the other two groups. Hematocrit was predicted to drop more with increased prostate size in acute normovolemic hemodilution and conventional groups but not with low central venous pressure. Limitations include the inability to blind providers to group assignment, possible variability between providers in estimation of blood loss, and the relatively small sample size that was not powered to detect differences between the groups in need for blood transfusion. Maintaining low central venous

  10. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  11. Correlation of Blood Gas Parameters with Central Venous Pressure in Patients with Septic Shock; a Pilot Study

    PubMed Central

    Baratloo, Alireza; Rahmati, Farhad; Rouhipour, Alaleh; Motamedi, Maryam; Gheytanchi, Elmira; Amini, Fariba; Safari, Saeed

    2014-01-01

    Objective: To determine the correlation between blood gas parameters and central venous pressure (CVP) in patients suffering from septic shock. Methods: Forty adult patients with diagnosis of septic shock who were admitted to the emergency department (ED) of Shohadaye Tajrish Hospital affiliated with Shahid Beheshti University of Medical Sciences, and met inclusion and exclusion criteria were enrolled. For all patients, sampling was done for venous blood gas analysis, serum sodium and chlorine levels. At the time of sampling; blood pressure, pulse rate and CVP were recorded. Correlation between blood gas parameters and hemodynamic indices were. Results: A significant direct correlation between CVP with anion gap (AG) and inversely with base deficit (BD) and bicarbonate. CVP also showed a relative correlation with pH, whereas it was not correlated with BD/ AG ratio and serum chlorine level. There was no significant association between CVP and clinical parameters including shock index (SI) and mean arterial pressure (MAP). Conclusion: It seems that some of non invasive blood gas parameters could be served as alternative to invasive measures such as CVP in treatment planning of patients referred to an ED with septic shock. PMID:27162870

  12. Arterial versus venous lactate: a measure of sepsis in children.

    PubMed

    Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip

    2017-08-01

    This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous

  13. Clinical features of venous insufficiency and the risk of venous thrombosis in older people.

    PubMed

    Engbers, Marissa J; Karasu, Alev; Blom, Jeanet W; Cushman, Mary; Rosendaal, Frits R; van Hylckama Vlieg, Astrid

    2015-11-01

    Venous thrombosis is common in older age, with an incidence of 0·5-1% per year in those aged >70 years. Stasis of blood flow is an important contributor to the development of thrombosis and may be due to venous insufficiency in the legs. The risk of thrombosis associated with clinical features of venous insufficiency, i.e., varicose veins, leg ulcers and leg oedema, obtained with a standardized interview was assessed in the Age and Thrombosis Acquired and Genetic risk factors in the Elderly (AT-AGE) study. The AT-AGE study is a case-control study in individuals aged 70 years and older (401 cases with a first-time venous thrombosis and 431 control subjects). We calculated odds ratios (ORs) and corresponding 95% confidence intervals (CI) adjusted for age, sex and study centre. Varicose veins and leg ulcer were associated with a 1·6-fold (95% CI 1·2-2·3) and 3·3-fold increased risk of thrombosis (95% CI 1·6-6·7), respectively, while the risk was increased 3·0-fold (95% CI 2·1-4·5) in the presence of leg oedema. The risk of thrombosis was highest when all three risk factors occurred simultaneously (OR: 10·5; 95% CI 1·3-86·1). In conclusion, clinical features of venous insufficiency, i.e., varicose veins, leg ulcers and leg oedema, are risk factors for venous thrombosis in older people. © 2015 John Wiley & Sons Ltd.

  14. Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA.

    PubMed

    Schrauben, E M; Johnson, K M; Huston, J; Del Rio, A M; Reeder, S B; Field, A; Wieben, O

    2014-05-01

    The chronic cerebrospinal venous insufficiency hypothesis raises interest in cerebrospinal venous blood flow imaging, which is more complex and less established than in arteries. For accurate assessment of venous flow in chronic cerebrospinal venous insufficiency diagnosis and research, we must account for physiologic changes in flow patterns. This study examines day-to-day flow variability in cerebrospinal veins by use of 4D MR flow and contrast-enhanced MRA under typical, uncontrolled conditions in healthy individuals. Ten healthy volunteers were scanned in a test-retest fashion by use of a 4D flow MR imaging technique and contrast-enhanced MRA. Flow parameters obtained from phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA scoring measurements in the head, neck, and chest veins were analyzed for internal consistency and interscan reproducibility. Internal consistency was satisfied at the torcular herophili, with an input-output difference of 2.2%. Percentages of variations in flow were 20.3%, internal jugular vein; 20.4%, azygos vein; 6.8%, transverse sinus; and 5.1%, common carotid artery. Retrograde flow was found in the lower internal jugular vein (4.8%) and azygos vein (7.2%). Contrast-enhanced MRA interscan κ values for the internal jugular vein (left: 0.474, right: 0.366) and azygos vein (-0.053) showed poor interscan agreement. Phase contrast-vastly undersampled isotropic projection reconstruction blood flow measurements are reliable and highly reproducible in intracranial veins and in the common carotid artery but not in veins of the neck (internal jugular vein) and chest (azygos vein) because of normal physiologic variation. Retrograde flow normally may be observed in the lower internal jugular vein and azygos vein. Low interrater agreement in contrast-enhanced MRA scans was observed. These findings have important implications for imaging diagnosis and experimental research of chronic cerebrospinal venous

  15. Cerebral venous circulatory system evaluation by ultrasonography.

    PubMed

    Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost

    2013-06-01

    Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.

  16. Order of draw practices in venous blood sampling at clinical biochemistry departments in the Danish health care system.

    PubMed

    Jacobsen, Katja Kemp; Brandt, Ida; Christensen, Anne Vindahl; Rimsø, Bjørk Anine; Krøier, Camilla Julie; Sørensen, Michelle; Smith, Julie; Jensen, Kathrine Overgaard Foss; Larsen, Jeppe Madura

    2018-06-01

    Deviation in blood collection procedures is a central source of preanalytical variation affecting overall analytical and diagnostic precision. The order of draw of venous sampling is suspected to affect analytical results, in particular for coagulation analysis. Here we compare the procedures in venous blood sampling among clinical biochemistry departments to assess the uniformity of order of blood draw and adherence to international guidelines in the Danish health care system. We collected venous order of draw procedures from 49 clinical biochemistry departments at 22 public hospitals in Denmark. Procedures were compared to the international guidelines fromthe Clinical Laboratory Standards Institute (CLSI) and World Health Organization (WHO), and assessed in relation to department ISO 15189:2012 accreditation. We observed seven different order of draw procedures related to citrate, serum, heparin, and EDTA tubes, and the use of discard tubes in relation to coagulation assays. 31 departments (63.3%) were found to adhere to CLSI and WHO guidelines. A majority of departments instructs the use of discard tubes before collection for coagulation assays in citrate tubes (44 departments; 89.8%). The citrate tube was the first sample tube to be drawn for most departments (35 departments; 75.5%); and the preferred order of non-citrate tubes was serum-heparin-EDTA (36 departments; 73.5%). Adherence to the CLSI and WHO guidelines was not associated with department ISO 15189:2012 accreditation (p = .57). Venous order of draw procedures is diverse at Danish clinical biochemistry departments and show moderate adherence to international guidelines. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Capillary and venous samples of total creatine kinase are similar after eccentric exercise.

    PubMed

    Knoblauch, Mark A; O'Connor, Daniel P; Clarke, Mark S F

    2010-12-01

    Circulating creatine kinase (CK) levels are often monitored as an indirect biomarker of muscle damage after resistive exercise. The purpose of the present investigation was to evaluate whether capillary whole-blood sampling, a simpler and less invasive method for obtaining a venous blood sample, would allow for a reliable measurement of total CK compared to venipuncture. Fifteen untrained subjects performed 50 maximal eccentric elbow extensions to induce muscle damage of the biceps brachii. Capillary (fingerstick) and venous whole-blood samples were collected contemporaneously at baseline and again at 24, 48, 72, and 96 hours post-exercise. Using a commercial CK analysis kit with a protocol modification to account for a reduced sample size, total CK activity of the capillary and venous samples was analyzed concurrently via spectrophotometry. Results indicated a 0.997 correlation between sampling sites for total CK, with disagreement between the venous and capillary samples estimated at <12% across the range of CK values. These findings indicate capillary sampling for total CK activity provides a valid alternative to venipuncture and should be considered by researchers, clinicians, and strength and conditioning specialists as an alternate sampling technique when indirectly evaluating muscle damage after exercise.

  18. Blood culture accuracy: discards from central venous catheters in pediatric oncology patients in the emergency department.

    PubMed

    Winokur, Elizabeth J; Pai, Debra; Rutledge, Dana N; Vogel, Kate; Al-Majid, Sadeeka; Marshall, Christine; Sheikewitz, Paul

    2014-07-01

    Lack of specific guidelines regarding collection of blood for culture from central venous catheters (CVCs) has led to inconsistencies in policies among hospitals. Currently, no specific professional or regulatory recommendations exist in relation to using, reinfusing, or discarding blood drawn from CVCs before drawing blood for a culture. Repeated wasting of blood may harm immunocompromised pediatric oncology patients. The purpose of this comparative study was to determine whether differences exist between blood cultures obtained from the first 5 mL of blood drawn from a CVC line when compared with the second 5 mL drawn. During 2009-2011, 62 pediatric oncology patients with CVCs and orders for blood cultures to determine potential sepsis were enrolled during ED visits. Trained study nurses aseptically drew blood and injected the normally discarded first 5 mL and the second specimen (usual care) into separate culture bottles. Specimens were processed in the microbiology laboratory per hospital policy. Positive cultures were evaluated to assess agreement between specimen results and to determine that the identified pathogen was not a contaminant. Out of 186 blood culture pairs, 4.8% demonstrated positive results. In all positive-positive matches, the normal discard specimen contained the same organism as the usual care specimen. In 4 matches, the normally discarded specimen demonstrated notably earlier time to positivity (4 to 31 hours) compared with the usual care specimen, which resulted in earlier initiation of definitive antibiotics. These findings support the accuracy of the specimen that is normally discarded and suggest the need to reconsider its use for blood culture testing. Copyright © 2014 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  19. Human cerebral venous outflow pathway depends on posture and central venous pressure

    PubMed Central

    Gisolf, J; van Lieshout, J J; van Heusden, K; Pott, F; Stok, W J; Karemaker, J M

    2004-01-01

    Internal jugular veins are the major cerebral venous outflow pathway in supine humans. In upright humans the positioning of these veins above heart level causes them to collapse. An alternative cerebral outflow pathway is the vertebral venous plexus. We set out to determine the effect of posture and central venous pressure (CVP) on the distribution of cerebral outflow over the internal jugular veins and the vertebral plexus, using a mathematical model. Input to the model was a data set of beat-to-beat cerebral blood flow velocity and CVP measurements in 10 healthy subjects, during baseline rest and a Valsalva manoeuvre in the supine and standing position. The model, consisting of 2 jugular veins, each a chain of 10 units containing nonlinear resistances and capacitors, and a vertebral plexus containing a resistance, showed blood flow mainly through the internal jugular veins in the supine position, but mainly through the vertebral plexus in the upright position. A Valsalva manoeuvre while standing completely re-opened the jugular veins. Results of ultrasound imaging of the right internal jugular vein cross-sectional area at the level of the laryngeal prominence in six healthy subjects, before and during a Valsalva manoeuvre in both body positions, correlate highly with model simulation of the jugular cross-sectional area (R2 = 0.97). The results suggest that the cerebral venous flow distribution depends on posture and CVP: in supine humans the internal jugular veins are the primary pathway. The internal jugular veins are collapsed in the standing position and blood is shunted to an alternative venous pathway, but a marked increase in CVP while standing completely re-opens the jugular veins. PMID:15284348

  20. Reduction of carboxyhaemoglobin levels in the venous blood of cigarette smokers following the administration of carbogen.

    PubMed

    Macdonald, Graham; Kondor, Natalie; Yousefi, Vandad; Green, Alex; Wong, Frances; Aquino-Parsons, Christina

    2004-12-01

    Cigarette smokers have high carboxyhaemoglobin levels which can promote tumour radioresistance. Inhalation of carbogen gas shortens the half-life of carboxyhaemoglobin, increasing tumour radiosensitivity in animal models. Breathing 2.5% carbogen for 30 min results in a greater reduction in venous blood COHb levels than breathing 5% carbogen for 7 min.

  1. A novel approach for assessing the progression of deep venous thrombosis by area of venous thrombus in ultrasonic elastography.

    PubMed

    Wang, Chao; Wang, Lei; Zhang, Yuhui; Chen, Ming

    2014-04-01

    Exact age determination of deep venous thrombosis (DVT) is important for an appropriate treatment. The purpose of this present study is to assess the age of acute DVT with the area of venous thrombi in elasticity imaging during the thrombosis procession. The thrombus area is obtained from a specially designed program. It was applied to clot specimens induced in human great saphenous (n = 15) at selected time points following the initiation of thrombosis. The relative mean proportion of blood clots was 50.01% ± 12.44% at day 1; 69.94% ± 8.19% at day 3; 81.93% ± 6.15% at day 6; and 92.37% ± 4.06% at day 9. The results indicated that the thrombus area increased significantly over time, while the normalized strain values inside the thrombus changed only a little. The pathological analyses also showed the same results. Therefore, we conclude that the area of venous thrombi in elasticity imaging may be a novel function for acute DVT staging.

  2. Quantification of phosphatidylethanol 16:0/18:1, 18:1/18:1, and 16:0/16:0 in venous blood and venous and capillary dried blood spots from patients in alcohol withdrawal and control volunteers.

    PubMed

    Kummer, Natalie; Ingels, Ann-Sofie; Wille, Sarah M R; Hanak, Catherine; Verbanck, Paul; Lambert, Willy E E; Samyn, Nele; Stove, Christophe P

    2016-01-01

    Phosphatidylethanol species (PEths) are promising biomarkers of alcohol consumption. Here, we report on the set-up, validation, and application of a novel UHPLC-ESI-MS/MS method for the quantification of PEth 16:0/18:1, PEth 18:1/18:1, and PEth 16:0/16:0 in whole blood (30 μL) and in venous (V, 30 μL) or capillary (C, 3 punches (3 mm)) dried blood spots (DBS). The methods were linear from 10 (LLOQ) to 2000 ng/mL for PEth 16:0/18:1, from 10 (LLOQ) to 1940 ng/mL for PEth 18:1/18:1, and from 19 (LLOQ) to 3872 ng/mL for PEth 16:0/16:0. Extraction efficiencies were higher than 55% (RSD < 18%) and matrix effects compensated for by IS were between 77 and 125% (RSD < 10%). Accuracy, repeatability, and intermediate precision fulfilled acceptance criteria (bias and RSD below 13%). Validity of the procedure for determination of PEth 16:0/18:1 in blood was demonstrated by the successful participation in a proficiency test. The quantification of PEths in C-DBS was not significantly influenced by the hematocrit, punch localization, or spot volume. The stability of PEths in V-DBS stored at room temperature was demonstrated up to 6 months. The method was applied to authentic samples (whole blood, V-DBS, and C-DBS) from 50 inpatients in alcohol withdrawal and 50 control volunteers. Applying a cut-off value to detect inpatients at 221 ng/mL for PEth 16:0/18:1 provided no false positive results and a good sensitivity (86%). Comparison of quantitative results (Bland-Altman plot, Passing-Bablok regression, and Wilcoxon signed rank test) revealed that V-DBS and C-DBS were valid alternatives to venous blood for the detection of alcohol consumption.

  3. Factor XIII in plasma, but not in platelets, mediates red blood cell retention in clots and venous thrombus size in mice

    PubMed Central

    Martin, Sara M.; Holle, Lori A.; Cooley, Brian C.; Flick, Matthew J.

    2018-01-01

    The transglutaminase factor XIII (FXIII) stabilizes clots against mechanical and biochemical disruption and is essential for hemostasis. In vitro and in vivo models of venous thrombosis demonstrate that FXIII mediates clot size by promoting red blood cell (RBC) retention. However, the key source of FXIII and whether FXIII activity can be reduced to suppress thrombosis without imposing deleterious hemostatic consequences are 2 critical unresolved questions. FXIII is present in multiple compartments, including plasma (FXIIIplasma) as a heterotetramer of A2 and B2 subunits and platelets (FXIIIplt) as an A2 homodimer. We determined the role of the FXIII compartment and level in clot contraction, composition, and size in vitro and using in vivo models of hemostasis and venous thrombosis. Reducing overall FXIII levels decreased whole blood clot weight but did not alter thrombin generation or contraction of platelet-rich plasma clots. In reconstituted platelet-rich plasma and whole blood clot contraction assays, FXIIIplasma, but not FXIIIplt, produced high-molecular-weight fibrin crosslinks, promoted RBC retention, and increased clot weights. Genetically imposed reduction of FXIII delayed FXIII activation and fibrin crosslinking, suggesting FXIII levels mediate the kinetics of FXIII activation and activity and that the timing of these processes is a critical determinant of RBC retention during clot formation and contraction. A 50% reduction in FXIIIplasma produced significantly smaller venous thrombi but did not increase bleeding in tail transection or saphenous vein puncture models in vivo. Collectively, these findings suggest that partial FXIII reduction may be a therapeutic strategy for reducing venous thrombosis. PMID:29344582

  4. Factor XIII in plasma, but not in platelets, mediates red blood cell retention in clots and venous thrombus size in mice.

    PubMed

    Kattula, Sravya; Byrnes, James R; Martin, Sara M; Holle, Lori A; Cooley, Brian C; Flick, Matthew J; Wolberg, Alisa S

    2018-01-09

    The transglutaminase factor XIII (FXIII) stabilizes clots against mechanical and biochemical disruption and is essential for hemostasis. In vitro and in vivo models of venous thrombosis demonstrate that FXIII mediates clot size by promoting red blood cell (RBC) retention. However, the key source of FXIII and whether FXIII activity can be reduced to suppress thrombosis without imposing deleterious hemostatic consequences are 2 critical unresolved questions. FXIII is present in multiple compartments, including plasma (FXIII plasma ) as a heterotetramer of A 2 and B 2 subunits and platelets (FXIII plt ) as an A 2 homodimer. We determined the role of the FXIII compartment and level in clot contraction, composition, and size in vitro and using in vivo models of hemostasis and venous thrombosis. Reducing overall FXIII levels decreased whole blood clot weight but did not alter thrombin generation or contraction of platelet-rich plasma clots. In reconstituted platelet-rich plasma and whole blood clot contraction assays, FXIII plasma , but not FXIII plt , produced high-molecular-weight fibrin crosslinks, promoted RBC retention, and increased clot weights. Genetically imposed reduction of FXIII delayed FXIII activation and fibrin crosslinking, suggesting FXIII levels mediate the kinetics of FXIII activation and activity and that the timing of these processes is a critical determinant of RBC retention during clot formation and contraction. A 50% reduction in FXIII plasma produced significantly smaller venous thrombi but did not increase bleeding in tail transection or saphenous vein puncture models in vivo. Collectively, these findings suggest that partial FXIII reduction may be a therapeutic strategy for reducing venous thrombosis.

  5. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    PubMed

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly

  6. Pulse oximetry in the pulmonary tissue for the non-invasive measurement of mixed venous oxygen saturation.

    PubMed

    Nitzan, Meir; Nitzan, Itamar

    2013-08-01

    The oxygen saturation of the systemic arterial blood is associated with the adequacy of respiration, and can be measured non-invasively by pulse oximetry in the systemic tissue. The oxygen saturation of the blood in the pulmonary artery, the mixed venous blood, reflects the balance between oxygen supply to the systemic tissues and their oxygen demand. The mixed venous oxygen saturation has also clinical significance because it is used in Fick equation for the quantitative measurement of cardiac output. At present the measurement of the mixed venous oxygen saturation is invasive and requires insertion of a Swan-Ganz catheter into the pulmonary artery. We suggest a noninvasive method for the measurement of the mixed venous oxygen saturation in infants, pulmonary pulse oximetry. The method is similar to the systemic pulse oximetry, which is based on the different light absorption curves of oxygenated and deoxygenated hemoglobin and on the analysis of photoplethysmographic curves in two wavelengths. The proposed pulmonary pulse oximeter includes light-sources of two wavelengths in the infrared, which illuminate the pulmonary tissue through the thoracic wall. Part of the light which is scattered back from the pulmonary tissue and passes through the thoracic wall is detected, and for each wavelength a pulmonary photoplethysmographic curve is obtained. The pulmonary photoplethysmographic curves reflect blood volume increase during systole in the pulmonary arteries in the lung tissue, which contain mixed venous blood. The ratio R of the amplitude-to-baseline ratio for the two wavelengths is related to the mixed venous oxygen saturation through equations derived for the systemic pulse oximetry. The method requires the use of extinction coefficients values for oxygenated and deoxygenated hemoglobin, which can be found in the literature. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. New method to calculate the N2 evolution from mixed venous blood during the N2 washout.

    PubMed

    Han, D; Jeng, D R; Cruz, J C; Flores, X F; Mallea, J M

    2001-08-01

    To model the normalized phase III slope (Sn) from N2 expirograms of the multibreath N2 washout is a challenge to researchers. Experimental measurements show that Sn increases with the number of breaths. Previously, we predicted Sn by setting the concentration (atm) of mixed venous blood (Fbi,N2) to a constant value of 0.3 after the fifth breath to calculate the amount of N2 transferred from the blood to the alveoli. As a consequence, the predicted curve of the Sn values showed a maximum before the quasi-steady state was reached. In this paper, we present a way of calculating the amount of N2 transferred from the blood to the alveoli by setting Fbi,N2 in the following way: In the first six breaths Fbi,N2 is kept constant at the initial value of 0.8 because circulation time needs at least 30 s to alter it. Thereafter, a single exponential function with respect the number of breaths is used: Fbi = 0.8 exp[0.112(6-n)], in which n is the breath number. The predicted Sn values were compared with experimental data from the literature. The assumption of an exponential decay in the N2 evolved from mixed venous blood is important in determining the shape of the Sn curve but new experimental data are needed to determine the validity of the model. We concluded that this new approach to calculate the N2 evolution from the blood is more meaningful physiologically.

  8. Venous Small Bowel Infarction: Intraoperative Laser Doppler Flowmetry Discriminates Critical Blood Supply and Spares Bowel Length

    PubMed Central

    Käser, S. A.; Glauser, P. M.; Maurer, C. A.

    2012-01-01

    Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon's decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome. PMID:23093968

  9. Comparability of HbA1c and lipids measured with dried blood spot versus venous samples: a systematic review and meta-analysis

    PubMed Central

    2014-01-01

    Background Levels of haemoglobin A1c (HbA1c) and blood lipids are important determinants of risk in patients with diabetes. Standard analysis methods based upon venous blood samples can be logistically challenging in resource-poor settings where much of the diabetes epidemic is occurring. Dried blood spots (DBS) provide a simple alternative method for sample collection but the comparability of data from analyses based on DBS is not well established. Methods We conducted a systematic review and meta-analysis to define the association of findings for HbA1c and blood lipids for analyses based upon standard methods compared to DBS. The Cochrane, Embase and Medline databases were searched for relevant reports and summary regression lines were estimated. Results 705 abstracts were found by the initial electronic search with 6 further reports identified by manual review of the full papers. 16 studies provided data for one or more outcomes of interest. There was a close agreement between the results for HbA1c assays based on venous and DBS samples (DBS = 0.9858venous + 0.3809), except for assays based upon affinity chromatography. Significant adjustment was required for assays of total cholesterol (DBS = 0.6807venous + 1.151) but results for triglycerides (DBS = 0.9557venous + 0.1427) were directly comparable. Conclusions For HbA1c and selected blood lipids, assays based on DBS samples are clearly associated with assays based on standard venous samples. There are, however, significant uncertainties about the nature of these associations and there is a need for standardisation of the sample collection, transportation, storage and analysis methods before the technique can be considered mainstream. This should be a research priority because better elucidation of metabolic risks in resource poor settings, where venous sampling is infeasible, will be key to addressing the global epidemic of cardiovascular diseases. PMID:25045323

  10. Motor neuron differentiation of iPSCs obtained from peripheral blood of a mutant TARDBP ALS patient.

    PubMed

    Bossolasco, Patrizia; Sassone, Francesca; Gumina, Valentina; Peverelli, Silvia; Garzo, Maria; Silani, Vincenzo

    2018-05-17

    Amyotrophic lateral sclerosis (ALS) is a severe neurodegenerative disease, mainly affecting the motor neurons (MNs) and without effective therapy. Drug screening is hampered by the lack of satisfactory experimental and pre-clinical models. Induced pluripotent stem cells (iPSCs) could help to define disease mechanisms and therapeutic strategies as they could be differentiated into MNs, otherwise inaccessible from living humans. In this study, given the seminal role of TDP-43 in ALS pathophysiology, MNs were obtained from peripheral blood mononuclear cells-derived iPSCs of an ALS patient carrying a p.A382T TARDBP mutation and a healthy donor. Venous samples were preferred to fibroblasts for their ease of collection and no requirement for time consuming extended cultures before experimentation. iPSCs were characterized for expression of specific markers, spontaneously differentiated into primary germ layers and, finally, into MNs. No differences were observed between the mutated ALS patient and the control MNs with most of the cells displaying a nuclear localization of the TDP-43 protein. In conclusion, we here demonstrated for the first time that human TARDBP mutated MNs can be successfully obtained exploiting the reprogramming and differentiation ability of peripheral blood cells, an easily accessible source from any patient. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Daily nursing care on patients undergoing venous-venous extracorporeal membrane oxygenation: a challenging procedure!

    PubMed

    Redaelli, Sara; Zanella, Alberto; Milan, Manuela; Isgrò, Stefano; Lucchini, Alberto; Pesenti, Antonio; Patroniti, Nicolò

    2016-12-01

    Daily nursing in critical care patients may alter vital parameters, especially in the most critically ill patients. The aim of our study was to evaluate feasibility and safety of daily nursing on patients undergoing venous-venous extracorporeal membrane oxygenation (vv-ECMO) for severe respiratory failure. Daily nursing was performed following defined phases (sponge bath, elevation with scooping stretcher, change position of endotracheal tube, dressing replacement). We recorded physiological and ECMO parameters before and during daily nursing in 5 patients for several days (total: 25 daily nursing) and adverse events: desaturation, hypertension, reduction of mixed venous oxygen saturation, arterial oxygen saturation or ECMO blood flow and elevation in minute ventilation. Sedative drug dosage and additional bolus were recorded. Daily nursing was performed in 92 % of cases (23/25), with a minimum of two adverse events per daily nursing. Hypertension and tachycardia were mostly recorded at the beginning, while desaturation, reduction in mixed venous oxygen saturation and blood flow were recorded during elevation with scooping stretcher. Increase in minute ventilation was frequent in spontaneous breathing patients. Additional bolus of sedation was required before and/or during nursing. Daily nursing significantly alters physiologic parameters; thus, it should be performed only when physicians are readily available to treat adverse events.

  12. The Essentials of Parathyroid Hormone Venous Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com; Trerotola, Scott O., E-mail: streroto@uphs.upenn.edu; Sacks, Barry, E-mail: bsacks@bidmc.harvard.edu

    Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage.more » Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.« less

  13. Attempts at estimating mixed venous carbon dioxide tension by the single-breath method.

    PubMed

    Ohta, H; Takatani, O; Matsuoka, T

    1989-01-01

    The single-breath method was originally proposed by Kim et al. [1] for estimating the blood carbon dioxide tension and cardiac output. Its reliability has not been proven. The present study was undertaken, using dogs, to compare the mixed venous carbon dioxide tension (PVCO2) calculated by the single-breath method with the PVCO2 measured in mixed venous blood, and to evaluate the influence of variations in the exhalation duration and the volume of expired air usually discarded from computations as the deadspace. Among the exhalation durations of 15, 30 and 45 s tested, the 15 s duration was found to be too short to obtain an analyzable O2-CO2 curve, but at either 30 or 45 s, the calculated values of PVCO2 were comparable to the measured PVCO2. A significant agreement between calculated and measured PVCO2 was obtained when the expired gas with PCO2 less than 22 Torr was considered as deadspace gas.

  14. [Controlled study of increasing venous tone in primary varicose veins by oral administration of Ruscus aculeatus and trimethylhespiridinchalcone].

    PubMed

    Weindorf, N; Schultz-Ehrenburg, U

    1987-01-01

    In a randomized double blind study, 50 patients suffering from trunk or branch varicosis were orally treated with either a commercial preparation of Ruscus extract, trimethyl hesperidine chalcone and ascorbic acid (Phlebodril), or a placebo over 2 weeks. Changes of the venous tonus were measured by means of venous occlusion plethysmography in rest position (venous capacity, venous distensibility) as well as during (active) exercise (expelled blood volume). All parameters showed a tendency towards improvement in the verum group. The changes were partly significant (p less than 0.5). The course of the study suggests that the period of treatment possibly was too short to obtain the full pharmacologic effect.

  15. Quantifying the effects of external shear loads on arterial and venous blood flow: implications for pressure ulcer development.

    PubMed

    Manorama, Abinand; Meyer, Ronald; Wiseman, Robert; Bush, Tamara Reid

    2013-06-01

    Forces applied to the skin cause a decrease in regional blood flow. This decrease in blood flow can cause tissue necrosis and lead to the formation of deep, penetrating wounds called pressure ulcers. These wounds are detrimental to individuals with compromised health, such as the elderly and spinal-cord injured. Although surface pressure is known to be a primary risk factor for developing a pressure ulcer, a seated individual rarely experiences pressure alone but rather combined loading which includes pressure as well as shear force on the skin. However, little research has been conducted to quantify the effects of shear forces on blood flow. Fifteen men were tested in a magnetic resonance imaging scanner under no load, a normal load, and a combination of normal and shear loads. Changes in arterial and venous blood flow in the forearm were measured using magnetic resonance angiography phase-contrast imaging. The blood flow in the anterior interosseous artery and basilic vein of the forearm decreased with the application of normal loads, and decreased further with the addition of shear loads. Marginal to significant differences at a 90% confidence level (P=0.08, 0.10) were observed, and medium to high effect sizes (0.3 to 0.5) were obtained. Based on these results, shear force is an important factor to consider in relation to pressure ulcer propagation and prevention, and hence, future prevention approaches should also focus on mitigating shear loads. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Correlation of Lactic Acid and Base Deficit Values Obtained From Arterial and Peripheral Venous Samples in a Pediatric Population During Intraoperative Care.

    PubMed

    Bordes, Brianne M; Walia, Hina; Sebastian, Roby; Martin, David; Tumin, Dmitry; Tobias, Joseph D

    2017-12-01

    Lactic acid and base deficit (BD) values are frequently monitored in the intensive care unit and operating room setting to evaluate oxygenation, ventilation, cardiac output, and peripheral perfusion. Although generally obtained from an arterial cannula, such access may not always be available. The current study prospectively investigates the correlation of arterial and peripheral venous values of BD and lactic acid. The study cohort included 48 patients. Arterial BD values ranged from -8 to 4 mEq/L and peripheral venous BD values ranged from -8 to 4 mEq/L. Arterial lactic acid values ranged from 0.36 to 2.45 μmol/L and peripheral venous lactic acid values ranged from 0.38 to 4 μmol/L. The arterial BD (-0.4 ± 2.2 mEq/L) was not significantly different from the peripheral venous BD (-0.6 ± 2.2 mEq/L). The arterial lactic acid (1.0 ± 0.5 μmol/L) was not significantly different from the peripheral venous lactic acid (1.1 ± 0.6 μmol/L). Pearson correlation coefficients demonstrated a very high correlation between arterial and peripheral venous BD ( r = .88, P < .001) and between arterial and peripheral venous lactic acid ( r = .67, P < .001). Bland-Altman plots of both pairs of measures showed that the majority of observations fell within the 95% limits of agreement. Least-squares regression indicated that a 1-unit increase in arterial BD corresponded to a 0.9-unit increase in peripheral venous BD (95% confidence interval [CI]: 0.7-1.0; P < .001) and a 1-unit increase in arterial lactic acid corresponded to a 0.9-unit increase in peripheral venous lactic acid (95% CI: 0.6-1.2; P < .001). These data demonstrate that there is a clinically useful correlation between arterial and peripheral venous lactic acid and BD values.

  17. Blood Accessibility to Fibrin in Venous Thrombosis is Thrombus Age-Dependent and Predicts Fibrinolytic Efficacy: An In Vivo Fibrin Molecular Imaging Study

    PubMed Central

    Stein-Merlob, Ashley F.; Kessinger, Chase W.; Erdem, S. Sibel; Zelada, Henry; Hilderbrand, Scott A.; Lin, Charles P.; Tearney, Guillermo J.; Jaff, Michael R.; Reed, Guy L.; Henke, Peter K.; McCarthy, Jason R.; Jaffer, Farouc A.

    2015-01-01

    Fibrinolytic therapy of venous thromboembolism (VTE) is increasingly utilized, yet limited knowledge is available regarding in vivo mechanisms that govern fibrinolytic efficacy. In particular, it is unknown how age-dependent thrombus organization limits direct blood contact with fibrin, the target of blood-based fibrinolytic agents. Utilizing high-resolution in vivo optical molecular imaging with FTP11, a near-infrared fluorescence (NIRF) fibrin-specific reporter, here we investigated the in vivo interrelationships of blood accessibility to fibrin, thrombus age, thrombus neoendothelialization, and fibrinolysis in murine venous thrombosis (VT). In both stasis VT and non-stasis VT, NIRF microscopy showed that FTP11 fibrin binding was thrombus age-dependent. FTP11 localized to the luminal surface of early-stage VT, but only minimally to subacute VT (p<0.001). Transmission electron microscopy of early stage VT revealed direct blood cell contact with luminal fibrin-rich surfaces. In contrast, subacute VT exhibited an encasing CD31+ neoendothelial layer that limited blood cell contact with thrombus fibrin in both VT models. Next we developed a theranostic strategy to predict fibrinolytic efficacy based on the in vivo fibrin accessibility to blood NIRF signal. Mice with variably aged VT underwent FTP11 injection and intravital microscopy (IVM), followed by tissue plasminogen activator infusion to induce VT fibrinolysis. Fibrin molecular IVM revealed that early stage VT, but not subacute VT, bound FTP11 (p<0.05), and experienced higher rates of fibrinolysis and total fibrinolysis (p<0.05 vs. subacute VT). Before fibrinolysis, the baseline FTP11 NIRF signal predicted the net fibrinolysis at 60 minutes (p<0.001). Taken together, these data provide novel insights into the temporal evolution of VT and its susceptibility to therapeutic fibrinolysis. Fibrin molecular imaging may provide a theranostic strategy to identify venous thrombi amenable to fibrinolytic therapies. PMID

  18. [Self-active physical thrombosis prophylaxis in the patients' bed with the Phlebostep: acceptance and measurement of venous blood flow in immobilized patients].

    PubMed

    Olivier, L C; Ostovan, D; Heywinkel, W; Kendoff, D; Wolfhard, U

    2007-11-01

    Despite the broad use of low molecular weight heparin, deep vein thrombosis is still a relevant risk for immobilized patients in orthopedic surgery. Patients can reduce this risk by active training exercises with a muscle pump. The aim of this study was to test the acceptance and effect of a self-developed training device to accelerate venous return as well as a technical optimization. The device was installed for in-patients in orthopedic and traumatology departments. A simple pillow-like device was developed, which can be positioned against the foot end of the patient's bed (Phlebostep). The device gives a sound-based feedback to the patient while pushing actively against it with complete ankle flexion. A digital integrated counter device allows direct feedback to the physician and nursing staff at any time. Initial testing including duplex sonography for venous flow measurements were done on 10 orthopedic in-patients. Prior testing on 7 healthy volunteers was carried out to define the effect of various amounts of pressure on the Phlebostep on the venous blood flow. Additionally, a questionnaire on the general acceptance and user-friendliness was filled out by 84 patients who had used the Phlebostep. The optimal pressure force was defined as 35 mmHg for further measurements. The venous flow measurements in the 10 postoperative patients revealed an increased venous blood flow in the affected leg by an average of 99.9%. Analysis of the questionnaire from the 84 patients showed a high degree of acceptance. In addition to the technical feasibility, this study showed that use of the Phlebostep resulted on average in a doubling of venous return. The increase of venous flow offers an additional effective device for thrombosis prophylaxis through patient's own active movements and is clearly superior to the use of devices such as antithrombosis stockings alone. The Phlebostep found a high degree of acceptance with the patients.

  19. Age differences in arterial and venous extra-cerebral blood flow in healthy adults: contributions of vascular risk factors and genetic variants.

    PubMed

    Raz, Naftali; Daugherty, Ana M; Sethi, Sean K; Arshad, Muzamil; Haacke, E Mark

    2017-08-01

    Sufficient cerebral blood flow (CBF) and venous drainage are critical for normal brain function, and their alterations can affect brain aging. However, to date, most studies focused on arterial CBF (inflow) with little attention paid to the age differences in venous outflow. We measured extra-cerebral arterial and venous blood flow rates with phase-contrast MRI and assessed the influence of vascular risk factors and genetic polymorphisms (ACE insertion/deletion, COMT val158met, and APOEε4) in 73 adults (age 18-74 years). Advanced age, elevated vascular risk, ACE Deletion, and COMT met alleles were linked to lower in- and outflow, with no effects of APOE ε4 noted. Lower age-related CBF rate was unrelated to brain volume and was observed only in val homozygotes of COMTval158met. Thus, in a disease-free population, age differences in CBF may be notable only in persons with high vascular risk and carriers of genetic variants associated with vasoconstriction and lower dopamine availability. It remains to be established if treatments targeting alleviation of the mutable factors can improve the course of cerebrovascular aging in spite of the immutable genetic influence.

  20. Computer-aided diagnostic detection system of venous beading in retinal images

    NASA Astrophysics Data System (ADS)

    Yang, Ching-Wen; Ma, DyeJyun; Chao, ShuennChing; Wang, ChuinMu; Wen, Chia-Hsien; Lo, ChienShun; Chung, Pau-Choo; Chang, Chein-I.

    2000-05-01

    The detection of venous beading in retinal images provides an early sign of diabetic retinopathy and plays an important role as a preprocessing step in diagnosing ocular diseases. We present a computer-aided diagnostic system to automatically detect venous beading of blood vessels. It comprises of two modules, referred to as the blood vessel extraction module and the venus beading detection module. The former uses a bell-shaped Gaussian kernel with 12 azimuths to extract blood vessels while the latter applies a neural network-based shape cognitron to detect venous beading among the extracted blood vessels for diagnosis. Both modules are fully computer-automated. To evaluate the proposed system, 61 retinal images (32 beaded and 29 normal images) are used for performance evaluation.

  1. Computational modeling of venous sinus stenosis in idiopathic intracranial hypertension

    PubMed Central

    Levitt, Michael R; McGah, Patrick M; Moon, Karam; Albuquerque, Felipe C; McDougall, Cameron G; Kalani, M Yashar S; Kim, Louis J; Aliseda, Alberto

    2016-01-01

    Background and Purpose Idiopathic intracranial hypertension has been associated with dural venous sinus stenosis in some patients, but the hemodynamic environment of the dural venous sinuses has not been quantitatively described. Here, we present the first such computational fluid dynamics model using patient-specific blood pressure measurements. Materials and Methods Six patients with idiopathic intracranial hypertension and at least one stenosis or atresia at the transverse-sigmoid sinus junction underwent MRV followed by cerebral venography and manometry throughout the dural venous sinuses. Patient-specific computational fluid dynamics models were created using MRV anatomy, with venous pressure measurements as boundary conditions. Blood flow and wall shear stress were calculated for each patient. Results Computational models of dural venous sinuses were successfully reconstructed in all six patients with patient-specific boundary conditions. Three patients demonstrated a pathologic pressure gradient (≥ 8 mm Hg) across four dural venous sinus stenoses. Small sample size precludes statistical comparisons, but average overall flow throughout the dural venous sinuses of patients with pathologic pressure gradients was higher than in those without (1041.00 ± 506.52 vs. 358.00 ± 190.95 mL/min). Wall shear stress was also higher across stenoses in patients with pathologic pressure gradients (37.66 ± 48.39 vs 7.02 ± 13.60 Pa). Conclusion The hemodynamic environment of the dural venous sinuses can be computationally modeled using patient-specific anatomy and physiological measurements in patients with idiopathic intracranial hypertension. There was substantially higher blood flow and wall shear stress in patients with pathological pressure gradients. PMID:27197986

  2. Time-dependent hardening of blood clots quantitatively measured in vivo with shear-wave ultrasound imaging in a rabbit model of venous thrombosis.

    PubMed

    Mfoumou, Etienne; Tripette, Julien; Blostein, Mark; Cloutier, Guy

    2014-02-01

    Provide in vivo blood clot hardening evolution with ultrasound using supersonic imaging of shear waves. We conducted a prospective study in flow stasis-induced venous thrombosis within jugular veins of white female New Zealand rabbits. Blood clot elasticity was noninvasively measured in vivo using the Young's modulus (in kilopascals), on a 2-hour and a 2-week periods after thrombus induction. Monitoring was followed by a necropsy and ex vivo mechanical characterization to validate the existence and elasticity of explanted thrombi. Stagnant blood in the region of interest underwent clotting and progressive hardening with thrombus aging. The mean Young's moduli varied from 1.0 ± 0.6 kPa (at 10 min) to 5.3 ± 1.6 kPa (at 2 hours), then to 25.0 ± 6.8 kPa (at 14 days) post-surgery. Mean ex vivo moduli of 6.2 ± 0.7 kPa at 2 hours and 29.0 ± 2.4 kPa at 2 weeks agreed with in vivo measures. Supersonic imaging of shear waves provides consistent quantitative non-invasive elasticity measurements not available with standard compression ultrasound imaging for diagnosing and following venous thromboembolism. This information translatable to humans could aid in determining whether continued anticoagulant treatment is necessary, especially in the setting of unprovoked venous thromboembolism. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Pathophysiology of spontaneous venous gas embolism

    NASA Technical Reports Server (NTRS)

    Lambertsen, C. J.; Albertine, K. H.; Pisarello, J. B.; Flores, N. D.

    1991-01-01

    The use of controllable degrees and durations of continuous isobaric counterdiffusion venous gas embolism to investigate effects of venous gas embolism upon blood, cardiovascular, and respiratory gas exchange function, as well as pathological effects upon the lung and its microcirculation is discussed. Use of N2O/He counterdiffusion permitted performance of the pathophysiologic and pulmonary microstructural effects at one ATA without hyperbaric or hypobaric exposures.

  4. Combined Recirculatory-compartmental Population Pharmacokinetic Modeling of Arterial and Venous Plasma S(+) and R(-) Ketamine Concentrations.

    PubMed

    Henthorn, Thomas K; Avram, Michael J; Dahan, Albert; Gustafsson, Lars L; Persson, Jan; Krejcie, Tom C; Olofsen, Erik

    2018-05-16

    The pharmacokinetics of infused drugs have been modeled without regard for recirculatory or mixing kinetics. We used a unique ketamine dataset with simultaneous arterial and venous blood sampling, during and after separate S(+) and R(-) ketamine infusions, to develop a simplified recirculatory model of arterial and venous plasma drug concentrations. S(+) or R(-) ketamine was infused over 30 min on two occasions to 10 healthy male volunteers. Frequent, simultaneous arterial and forearm venous blood samples were obtained for up to 11 h. A multicompartmental pharmacokinetic model with front-end arterial mixing and venous blood components was developed using nonlinear mixed effects analyses. A three-compartment base pharmacokinetic model with additional arterial mixing and arm venous compartments and with shared S(+)/R(-) distribution kinetics proved superior to standard compartmental modeling approaches. Total pharmacokinetic flow was estimated to be 7.59 ± 0.36 l/min (mean ± standard error of the estimate), and S(+) and R(-) elimination clearances were 1.23 ± 0.04 and 1.06 ± 0.03 l/min, respectively. The arm-tissue link rate constant was 0.18 ± 0.01 min and the fraction of arm blood flow estimated to exchange with arm tissue was 0.04 ± 0.01. Arterial drug concentrations measured during drug infusion have two kinetically distinct components: partially or lung-mixed drug and fully mixed-recirculated drug. Front-end kinetics suggest the partially mixed concentration is proportional to the ratio of infusion rate and total pharmacokinetic flow. This simplified modeling approach could lead to more generalizable models for target-controlled infusions and improved methods for analyzing pharmacokinetic-pharmacodynamic data.

  5. Manual lymphatic drainage in chronic venous disease: a duplex ultrasound study.

    PubMed

    Dos Santos Crisóstomo, Rute Sofia; Candeias, Miguel Sandu; Ribeiro, Ana Margarida Martins; da Luz Belo Martins, Catarina; Armada-da-Silva, Paulo As

    2014-12-01

    To compare the effect of call-up and reabsorption maneuvers of manual lymphatic drainage on blood flow in femoral vein and great saphenous vein in patients with chronic venous disease and healthy controls. Forty-one subjects participated in this study (mean age: 42.68(15.23)), 23 with chronic venous disease (chronic venous disease group) with clinical classification C1-5 of clinical-etiological-anatomical-pathological (CEAP) and 18 healthy subjects (control group). Call-up and reabsorption maneuvers were randomly applied in the medial aspect of the thigh. The cross-sectional areas, as well as the peak and the mean blood flow velocity at femoral vein and great saphenous vein, were assessed by Duplex ultrasound at the baseline and during maneuvers. The venous flow volume changes were calculated. The venous flow volume in femoral vein and great saphenous vein increased during both manual lymphatic drainage maneuvers and in both groups (P < 0.05). The two maneuvers had a similar effect on femoral vein and great saphenous vein hemodynamics, and in both the chronic venous disease and control groups. As a result of the call-up maneuver, the flow volume augmentations, as a result of call-up maneuver, decreased with the severity of chronic venous disease in those patients measured by the clinical classification of CEAP (r = -0.64; P = 0.03). Manual lymphatic drainage increases the venous blood flow in the lower extremity with a magnitude that is independent from the specific maneuver employed or the presence of chronic venous disease. Therefore, manual lymphatic drainage may be an alternative strategy for the treatment and prevention of venous stasis complications in chronic venous disease. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. Correlation between the hemodynamic gain obtained after operation of primary varicose veins and chronic venous disease classification.

    PubMed

    Dezotti, Nei Rodrigues Alves; Joviliano, Edwaldo Edner; Moriya, Takachi; Piccinato, Carlos Eli

    2011-01-01

    Previous studies have demonstrated improvement of venous hemodynamics after surgical treatment of primary varicose veins of the lower extremities using air plethysmography (APG). To correlate the venous hemodynamics obtained by APG with the CEAP classification after surgical treatment of primary varicose veins. We studied 63 limbs of 39 patients (35 women and 4 men) aged on average 46.3 years, operated upon at the University Hospital, Faculty of Medicine of Ribeirão Preto, University of São Paulo, during the period from January 2001 to December 2004. The 63 limbs were divided into the three following groups according to CEAP classification: group C2 + C3 (38 limbs), group C4 (15 limbs) and group C5 + C6 (10 limbs). The patients were evaluated clinically before and 30 to 40 days after surgery by preoperative duplex ultrasonography and pre- and postoperative APG. There was an apparent hemodynamic improvement after surgical treatment of the varicose veins in the two groups of lower severity, but the improvement was significant in the most severe group based on venous filling index. Surgical treatment was beneficial for all three groups, but the greatest hemodynamic gain was observed in the group of highest clinical severity (group C5 + C6).

  7. [Venous thrombosis associated with central venous catheter use in patients with cancer].

    PubMed

    Iglesias Rey, Leticia; Fernández Pérez, Isaura; Barbagelata López, Cristina; Rivera Gallego, Alberto

    2015-01-01

    The use of central venous catheters for various applications (administration of chemotherapy, blood products and others) in patients with cancer is increasingly frequent. The association between thrombosis and catheter use has been fully established but aspects such as its causes, diagnosis, prophylaxis and treatment have not. We describe a case of thrombosis in a patient with cancer treated with chemotherapy who carried a central venous catheter. We also perform a review of the risk factors, the role of the prophylaxis and the treatment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  8. Venous and Arterial Thromboses: Two Sides of the Same Coin?

    PubMed

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-04-01

    Arterial and venous thromboses are sustained by development of intraluminal thrombi, respectively, within the venous and arterial systems. The composition and structure of arterial and venous thrombi have been historically considered as being very different. Arterial thrombi (conventionally defined as "white") have been traditionally proposed to be composed mainly of fibrin and platelet aggregates, whilst venous thrombi (conventionally defined as "red") have been proposed as mostly being enriched in fibrin and erythrocytes. This archaic dichotomy seems ever more questionable, since it barely reflects the pathophysiology of thrombus formation in vivo. Both types of thrombi are actually composed of a complex fibrin network but, importantly, also contain essentially the same blood-borne cells (i.e., red blood cells, leukocytes, and platelets), and it is only the relative content of these individual elements that differ between venous and arterial clots or, otherwise, between thrombi generated under different conditions of blood flow and shear stress. Convincing evidence now suggests that either white or red intracoronary thrombi may be present in patients with myocardial infarction and, even more importantly, red thrombi may be more prone to distal embolization during percutaneous coronary intervention than those with lower content of erythrocytes. Conversely, it is now accepted that components traditionally considered to be involved "only" in arterial thrombosis are also represented in venous thrombosis. Thus, platelets comprise important components of venous clots, although they may be present in lower amounts here than in arterial thrombi, and von Willebrand factor is also represented in both arterial and venous thrombi. Of importance, such evidence thus supports the concept that adjunctive treatment normally associated to prevention of arterial thrombosis (e.g., aspirin) may have a role also in prevention and treatment of venous thrombosis. Thieme Medical

  9. Effect of sequential pneumatic compression therapy on venous blood velocity, refilling time, pain and quality of life in women with varicose veins: a randomized control study

    PubMed Central

    Yamany, Abeer; Hamdy, Bassant

    2016-01-01

    [Purpose] The aim of this study was to investigate the effects of sequential pneumatic compression therapy on venous blood flow, refilling time, pain level, and quality of life in women with varicose veins. [Subjects and Methods] Twenty-eight females with varicose veins were selected and randomly allocated to a control group, and experimental group. Maximum and mean venous blood velocities, the refilling time, pain by visual analog scale and quality of life by Aberdeen Varicose Veins Questionnaire were measured in all patients before and after six weeks of treatment. Both groups received lower extremity exercises; in addition, patients in the experimental group received sequential pneumatic compression therapy for 30 minutes daily, five days a week for six weeks. [Results] All measured parameters improved significantly in both groups, comparison of post treatment measurements between groups showed that the maximum and mean blood flow velocity, the pain level, and quality of life were significantly higher in the experimental group compared with the control group. On the other hand there was no significant difference between groups for refilling time. [Conclusion] Sequential pneumatic compression therapy with the applied parameters was an effective modality for increasing venous blood flow, reducing pain, and improving quality of women life with varicose veins. PMID:27512247

  10. Penile blood flow by xenon-133 washout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haden, H.T.; Katz, P.G.; Mulligan, T.

    1989-06-01

    Penile erectile failure is often attributed to abnormalities of vascular supply or drainage, but few direct measurements of penile blood flow have been made. We describe the xenon washout method for measurement of penile blood flow, and present the results obtained in a group of normal and impotent subjects. The procedure was performed with standard nuclear imaging equipment. Flaccid-state penile blood flow in the impotent patients studied was not significantly different from the normal group, suggesting that flaccid-state measurements may not be helpful in evaluation of erectile failure. However, this method can be used to measure penile venous outflow withmore » stimulated or induced erection, and may provide a method for detecting abnormal venous leakage.« less

  11. Does the method of expression of venous blood affect ischaemia/reperfusion damage in tourniquet use? An experimental study on rabbits.

    PubMed

    Iltar, Serkan; Kılınç, Cem Yalın; Alemdaroğlu, Kadir Bahadır; Ozcan, Selahattin; Aydoğan, Nevres Hürriyet; Sürer, Hatice; Kılınç, Aytün Şadan

    2013-11-01

    The aim of this study was to compare the ischaemia and reperfusion phases of two tourniquet application models (Group 1: expressing the blood by a sterile rubber bandage and Group 2: elevation of the limb for several minutes) using an analysis of ischaemia/reperfusion parameters and blood pH. Sixteen New Zealand rabbits were used. Muscle samples were extracted from the triceps surae; at phase A (baseline: just before tourniquet application), phase B (ischaemia: 3h after tourniquet inflation) and phase C (2h after tourniquet deflation). Nitrite, nitrate, reduced glutathione, myeloperoxidase, malondyaldehyde were measured in the samples. Blood pH was also measured at each phase. Group 2 had significantly decreased nitrite (p=0.007) and nitrate (p=0.01) levels compared to Group 1 while passing from phase A to phase B. The pH decrease through the phases was significant within Group 1 (p=0.006) and was not significant within Group 2 (p=0.052). Lower levels of NO metabolites nitrate and nitrite, result from tourniquet use with incomplete venous blood expression by elevation. Also, with this technique severe acidosis is less likely to occur than when a tourniquet is used with expression of the venous blood by rubber bandage. These findings may help in the decision of which tourniquet technique is to be used for potentially long operations which may exceed 2h. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Analysis of the dynamics of venous blood flow in the context of lower limb temperature distribution and tissue composition in the elderly.

    PubMed

    Skomudek, Aleksandra; Gilowska, Iwona; Jasiński, Ryszard; Rożek-Piechura, Krystyna

    2017-01-01

    The elderly are particularly vulnerable to degenerative diseases, such as circulatory and respiratory system and vascular system diseases. The objective of this study was therefore to evaluate the distribution of temperature and the dynamics of venous blood flow in the lower limbs (LLs) and to assess the interdependence of these parameters in terms of the somatic components in males and females participating in activities at the University of the Third Age. The study included 60 females (mean age 67.4 years) and 40 males (mean age 67.5 years). A body composition assessment was performed using the bioimpedance technique - Tanita BC-418MA. The following parameters were examined: fat%, fat mass, fat-free mass, and total body water. The minimal, maximal, and mean temperature values and their distributions were examined using infrared thermographic camera VarioCAM Head. Measurements of the venous refilling time and the work of the LL venous pump were examined using a Rheo Dopplex II PPG. In males, the mean value of the right LL temperature was 30.58 and the mean value of the left LL was 30.28; the P -value was 0.805769. In females, the mean value of the right LL temperature was 29.58 and the mean value of the left limb was 29.52; the P -value was 0.864773. In males, the right limb blood flow was 34.17 and the left limb blood flow was 34.67; the P -value was 0.359137. In females, the right limb blood flow was 26.89 and the left limb blood flow was 26.09; the P -value was 0.796348. Research results showed that the temperature distribution and the dynamics of blood flow are not significantly different between the right and left extremities in both males and females. However, significant temperature differences were found between the gender groups. Significantly higher temperature values in both the right and left extremities were recorded in males than in females.

  13. Central Venous Catheter (Central Line)

    MedlinePlus

    ... the skin entry site. With care, central venous catheters can remain in the body for several months without becoming infected. ■ ■ Blocking or kinking— Blood clots may begin to form in the catheter but ...

  14. Venous thromboembolism and arterial complications.

    PubMed

    Prandoni, Paolo; Piovella, Chiara; Pesavento, Raffaele

    2012-04-01

    An increasing body of evidence suggests the likelihood of a link between venous and arterial thrombosis. The two vascular complications share several risk factors, such as age, obesity, smoking, diabetes mellitus, blood hypertension, hypertriglyceridemia, and metabolic syndrome. Moreover, there are many examples of conditions accounting for both venous and arterial thrombosis, such as the antiphospholipid antibody syndrome, hyperhomocysteinemia, malignancies, infections, and the use of hormonal treatment. Finally, several recent studies have consistently shown that patients with venous thromboembolism are at a higher risk of arterial thrombotic complications than matched control individuals. We, therefore, speculate the two vascular complications are simultaneously triggered by biological stimuli responsible for activating coagulation and inflammatory pathways in both the arterial and the venous system. Future studies are needed to clarify the nature of this association, to assess its extent, and to evaluate its implications for clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Dried blood spot measurement: application in tacrolimus monitoring using limited sampling strategy and abbreviated AUC estimation.

    PubMed

    Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo

    2008-02-01

    Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.

  16. Serial alterations in digital hemodynamics and endothelin-1 immunoreactivity, platelet-neutrophil aggregation, and concentrations of nitric oxide, insulin, and glucose in blood obtained from horses following carbohydrate overload.

    PubMed

    Eades, Susan C; Stokes, Ashley M; Johnson, Philip J; LeBlanc, Casey J; Ganjam, Venkataseshu K; Buff, Preston R; Moore, Rustin M

    2007-01-01

    To quantify changes in endothelium-derived factors and relate those changes to various aspects of digital hemodynamics during the prodromal stages of carbohydrate overload (CHO)-induced laminitis in horses. 20 adult horses without abnormalities of the digit. Digital and jugular venous blood samples were collected at 1-hour intervals (for assessment of endothelin-1 [ET-1] immunoreactivity and measurement of glucose, insulin, and nitric oxide [NO] concentrations) or 4-hour intervals (CBC and platelet-neutrophil aggregate assessment) for 8 hours or 16 hours after induction of CHO-associated laminitis in horses treated with an ET-1 antagonist. Effects of treatment, collection site, and time and the random effects of horse on each variable were analyzed by use of a repeated-measures model. Where treatment and collection site had no significant effect, data were combined. Compared with baseline values, CHO resulted in changes in several variables, including a significant increase from baseline in digital blood ET-like immunoreactivity at 11 hours; digital blood ET-like immunoreactivity was significantly greater than that in jugular venous blood at 8, 9, 11, and 12 hours. Digital and jugular venous blood concentrations of glucose increased from baseline significantly at 3, 4, and 5 hours; insulin concentration increased significantly at 5 hours; and the number of platelet-neutrophil aggregates increased significantly at 12 hours. In horses, concurrent increases in venous blood ET-1 immunoreactivity, insulin and glucose concentrations, and platelet-neutrophil aggregates support a role of endothelial dysfunction in the pathogenesis of CHO-induced laminitis.

  17. Thermographic venous blood flow characterization with external cooling stimulation

    NASA Astrophysics Data System (ADS)

    Saxena, Ashish; Ng, E. Y. K.; Raman, Vignesh

    2018-05-01

    Experimental characterization of blood flow in a human forearm is done with the application of continuous external cooling based active thermography method. Qualitative and quantitative detection of the blood vessel in a thermal image is done, along with the evaluation of blood vessel diameter, blood flow direction, and velocity in the target blood vessel. Subtraction based image manipulation is performed to enhance the feature contrast of the thermal image acquired after the removal of external cooling. To demonstrate the effect of occlusion diseases (obstruction), an external cuff based occlusion is applied after the removal of cooling and its effect on the skin rewarming is studied. Using external cooling, a transit time method based blood flow velocity estimation is done. From the results obtained, it is evident that an external cooling based active thermography method can be used to develop a diagnosis tool for superficial blood vessel diseases.

  18. Cardiovascular Deconditioning and Venous Air Embolism in Simulated Microgravity in the Rat

    NASA Technical Reports Server (NTRS)

    Robinson, R. R.; Doursout, M.-F.; Chelly, J. E.; Powell, M. R.; Little, T. M.; Butler,B. D.

    1996-01-01

    Astronauts conducting extravehicular activities undergo decompression to a lower ambient pressure, potentially resulting in gas bubble formation within the tissues and venous circulation. Additionally, exposure to microgravity produces fluid shifts within the body leading to cardiovascular deconditioning. A lower incidence of decompression illness in actual spaceflight compared with that in ground-based altitude chamber flights suggests that there is a possible interaction between microgravity exposure and decompression illness. The purpose of this study was to evaluate the cardiovascular and pulmonary effects of simulated hypobaric decompression stress using a tail suspension (head-down tilt) model of microgravity to produce the fluid shifts associated with weightlessness in conscious, chronically instrumented rats. Venous bubble formation resulting from altitude decompression illness was simulated by a 3-h intravenous air infusion. Cardiovascular deconditioning was simulated by 96 h of head-down tilt. Heart rate, mean arterial blood pressure, central venous pressure, left ventricular wall thickening and cardiac output were continuously recorded. Lung studies were performed to evaluate edema formation and compliance measurement. Blood and pleural fluid were examined for changes in white cell counts and protein concentration. Our data demonstrated that in tail-suspended rats subjected to venous air infusions, there was a reduction in pulmonary edema formation and less of a decrease in cardiac output than occurred following venous air infusion alone. Mean arterial blood pressure and myocardial wall thickening fractions were unchanged with either tail-suspension or venous air infusion. Heart rate decreased in both conditions while systemic vascular resistance increased. These differences may be due in part to a change or redistribution of pulmonary blood flow or to a diminished cellular response to the microvascular insult of the venous air embolization.

  19. [Effects of lidocaine on arterial and venous circulation of limbs in man].

    PubMed

    Edouard, A; Probst, D; Duranteau, J; Tarot, J P; Pussard, E

    1991-01-01

    The effects of intravenous lidocaine on limb arteries and veins were investigated in a placebo-controlled study. Seven young healthy volunteers, 23 to 28-years-old, were included. Electrocardiogram, arterial pressure and arm and leg blood flows were recorded continuously. Systolic and diastolic blood pressures were measured in the left arm by finger photoplethysmography. Limb blood flow and the limb venous system were studied by venous occlusive plethysmography. The venous parameters studied were venous tone, lowest closing pressure, venous volume at 30 mmHg, and venous distensibility. After an initial bolus of 1.5 mg.kg-1 lidocaine had been given, 30, and then 60, micrograms.kg-1.min-1 were given for one hour each. Plasma noradrenaline and serum lidocaine titres were measured before giving the lidocaine, and at the end of each one hour period. Placebo consisted in a two hour infusion of 0.25 ml.min-1 normal saline. Lidocaine titres were 1.64 +/- 0.40 microgram.ml-1 after one hour, and 2.55 +/- 0.69 microgram.ml-1 after two hours. Lidocaine increased vascular resistances in both the forearm (+81% to +93%) and the calf (+38% to +57%). There was a concomitant increase in mean arterial blood pressure (+21% to +28%) without any change in heart rate. There was a significant dose-dependent increase in plasma noradrenaline levels during the second period of the lidocaine infusion with respect to the preinfusion period and the same period during the placebo infusion. Venous capacitance measured before any infusion had been started was greater in the leg than in the arm.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. The possibility for use of venous flaps in plastic surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.

    2015-11-17

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less

  1. DKA, CVL and DVT. Increased risk of deep venous thrombosis in children with diabetic ketoacidosis and femoral central venous lines.

    PubMed

    Davis, J; Surendran, T; Thompson, S; Corkey, C

    2007-01-01

    Incidence of type 1 diabetes mellitus is continuing to rise in children. The presentation of diabetic ketoacidosis (DKA) in children with newly diagnosed diabetes is significantly higher in those less than 5 years old. Critically ill patients admitted to Paediatric Intensive Care Units (PICU), would have a central venous line (CVL) inserted as part of their ongoing management. There are associations linking with the development of deep venous thrombosis (DVT) in DKA/CVL patients. An 18-month-old boy presented with a short history of polydypsia, polyuria and weight loss. The initial blood sugar was 27.0 mmol/L and a venous blood gas showed severe metabolic acidosis. He was diagnosed and treated for DKA. He was transferred to the regional PICU for further management. There, a central venous line (CVL) was inserted in his left femoral vein. This was removed on Day 4. Subsequently, he developed a swelling on his left leg, with significant discrepancy in leg circumference. Doppler ultrasound confirmed a deep venous thrombosis. Conclusion Diabetes has a propensity for hypercoagulability and DKA promotes a prothrombotic state. Retrospective studies have shown younger patients with DKA and a femoral CVL are at higher risk of developing DVT. A central femoral line should avoided in such patients. DVT prophylaxis and Doppler follow up should also be considered.

  2. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  3. Venous or arterial blood components trigger more brain swelling, tissue death after acute subdural hematoma compared to elderly atrophic brain with subdural effusion (SDE) model rats.

    PubMed

    Wajima, Daisuke; Sato, Fumiya; Kawamura, Kenya; Sugiura, Keisuke; Nakagawa, Ichiro; Motoyama, Yasushi; Park, Young-Soo; Nakase, Hiroyuki

    2017-09-01

    Acute subdural hematoma (ASDH) is a frequent complication of severe head injury, whose secondary ischemic lesions are often responsible for the severity of the disease. We focused on the differences of secondary ischemic lesions caused by the components, 0.4ml venous- or arterial-blood, or saline, infused in the subdural space, evaluating the differences in vivo model, using rats. The saline infused rats are made for elderly atrophic brain with subdural effusion (SDE) model. Our data showed that subdural blood, both venous- and arterial-blood, aggravate brain edema and lesion development more than SDE. This study is the first study, in which different fluids in rats' subdural space, ASDH or SDE are compared with the extension of early and delayed brain damage by measuring brain edema and histological lesion volume. Blood constituents started to affect the degree of ischemia underneath the subdural hemorrhage, leading to more pronounced breakdown of the blood-brain barrier and brain damage. This indicates that further strategies to treat blood-dependent effects more efficiently are in view for patients with ASDH. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Abnormalities in the cellular phase of blood fibrinolytic activity in systemic lupus erythematosus and in venous thromboembolism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moroz, L.A.; MacLean, L.D.; Langleben, D.

    1986-09-15

    Fibrinolytic activities of whole blood and plasma were determined by /sup 125/I-fibrin radiometric assay in 16 normal subjects, and in 11 patients with systemic lupus erythematosus (SLE), 14 with progressive systemic sclerosis (PSS), 23 with venous thromboembolic disease, and 20 patients awaiting elective surgery. Mean whole blood and plasma activities for patients with PSS, and for those awaiting elective surgery, were similar to normal values, as was the mean plasma activity in patients with SLE. However, mean whole blood activity in SLE was significantly decreased compared with normals (p less than 0.05), with mean plasma activity accounting for 44% ofmore » mean whole blood activity (compared with 17% in normal subjects), representing a 67% decrease in mean calculated cellular phase activity in SLE, when compared with normals. Since the numbers of cells (neutrophils, monocytes) possibly involved in cellular activity were not decreased, the findings suggest a functional defect in fibrinolytic activity of one or more blood cell types in SLE. An additional finding was the participation of the cellular phase as well as the well-known plasma phase of blood in the fibrinolytic response to thromboembolism.« less

  5. Personal Computer System for Automatic Coronary Venous Flow Measurement

    PubMed Central

    Dew, Robert B.

    1985-01-01

    We developed an automated system based on an IBM PC/XT Personal computer to measure coronary venous blood flow during cardiac catheterization. Flow is determined by a thermodilution technique in which a cold saline solution is infused through a catheter into the coronary venous system. Regional temperature fluctuations sensed by the catheter are used to determine great cardiac vein and coronary sinus blood flow. The computer system replaces manual methods of acquiring and analyzing temperature data related to flow measurement, thereby increasing the speed and accuracy with which repetitive flow determinations can be made.

  6. Blood oxygen binding in hypoxaemic calves.

    PubMed

    Cambier, Carole; Clerbaux, Thierry; Detry, Bruno; Marville, Vincent; Frans, Albert; Gustin, Pascal

    2002-01-01

    Blood oxygen transport and tissue oxygenation were studied in 28 calves from the Belgian White and Blue breed (20 healthy and 8 hypoxaemic ones). Hypoxaemic calves were selected according to their high respiratory frequency and to their low partial oxygen pressure (PaO2) in the arterial blood. Venous and arterial blood samples were collected, and 2,3-diphosphoglycerate, adenosine triphosphate, chloride, inorganic phosphate and hemoglobin concentrations, and pH, PCO, and PO2 were determined. An oxygen equilibrium curve (OEC) was measured in standard conditions, for each animal. The arterial and venous OEC were calculated, taking body temperature, pH and PCO2 values in arterial and venous blood into account. The oxygen exchange fraction (OEF%), corresponding to the degree of blood desaturation between the arterial and the venous compartments, and the amount of oxygen released at the tissue level by 100 mL of blood (OEF Vol%) were calculated from the arterial and venous OEC combined with the PO2 and hemoglobin concentration. In hypoxaemic calves investigated in this study, the hemoglobin oxygen affinity, measured under standard conditions, was not modified. On the contrary, in vivo acidosis and hypercapnia induced a decrease in the hemoglobin oxygen affinity in arterial blood, which combined to the decrease in PaO2 led to a reduced hemoglobin saturation degree in the arterial compartment. However, this did not impair the oxygen exchange fraction (OEF%), since the hemoglobin saturation degree in venous blood was also diminished.

  7. The origin of mean arterial and jugular venous blood pressures in giraffes.

    PubMed

    Mitchell, Graham; Maloney, Shane K; Mitchell, Duncan; Keegan, D James

    2006-07-01

    Using a mechanical model of the giraffe neck and head circulation consisting of a rigid, ascending, 'carotid' limb, a 'cranial' circulation that could be rigid or collapsible, and a descending, 'jugular' limb that also could be rigid or collapsible, we have analyzed the origin of the high arterial and venous pressures in giraffe, and whether blood flow is assisted by a siphon. When the tubes were rigid and the 'jugular' limb exit was lower than the 'carotid' limb entrance a siphon operated, 'carotid' hydrostatic pressures became more negative, and flow was 3.3 l min(-1) but ceased when the 'cranial' and 'jugular' limbs were collapsible or when the 'jugular' limb was opened to the atmosphere. Pumping water through the model produced positive pressures in the 'carotid' limb similar to those found in giraffe. Applying an external 'tissue' pressure to the 'jugular' tube during pump flow produced the typical pressures found in the jugular vein in giraffe. Constriction of the lowest, 'jugular cuff', portion of the 'jugular' limb showed that the cuff may augment the orthostatic reflex during head raising. Except when all tubes were rigid, pressures were unaffected by a siphon. We conclude that mean arterial blood pressure in giraffes is a consequence of the hydrostatic pressure generated by the column of blood in the neck, that tissue pressure around the collapsible jugular vein produces the known jugular pressures, and that a siphon does not assist flow through the cranial circulation.

  8. Concentrations of zolpidem and zopiclone in venous blood samples from impaired drivers compared with femoral blood from forensic autopsies.

    PubMed

    Jones, Alan Wayne; Holmgren, Anita

    2012-10-10

    The concentrations of zolpidem and zopiclone were determined in peripheral blood samples in two forensic materials collected over a 10-year period (2001-2010). The z-hypnotics were determined in venous blood from living subjects (impaired drivers) and in femoral blood from deceased persons (forensic autopsies), with the latter classified as intoxication or other causes of death. The z-hypnotics were determined in blood by capillary column gas chromatography (GC) with a nitrogen-phosphorous (N-P) detector after solvent extraction with n-butyl acetate. The analytical limit of quantitation (LOQ) was 0.02 mg/L for zopiclone and 0.05 mg/L for zolpidem and these have remained unchanged throughout the study. When death was attributed to drug intoxication (N=918), the median concentration of zopiclone in blood was 0.20 mg/L compared with 0.06 mg/L for other causes of death (N=1215) and 0.07 mg/L in traffic offenders (N=691) (p<0.001). Likewise, a higher median concentration (0.30 mg/L) was found in intoxication deaths involving zolpidem (N=357) compared with 0.13 mg/L for other causes of death (N=397) or 0.19 mg/L in impaired drivers (N=837) (p<0.001). Median concentration in blood of both z-hypnotics were appreciably higher in intoxication deaths when no other substances were identified; 0 70 mg/L (N=12) for zopiclone and 1.35 mg/L (N=12) for zolpidem. The median concentrations of z-hypnotics in blood decreased as the number of co-ingested substances increased for intoxication deaths but not other causes of death. The most prevalent co-ingested substances were ethanol in autopsy cases and diazepam in the motorists. This large compilation of forensic cases should prove useful when toxicologists are required to interpret concentrations of z-hypnotics in blood samples in relation to cause of death. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Skin antiseptics in venous puncture site disinfection for preventing blood culture contamination: A Bayesian network meta-analysis of randomized controlled trials.

    PubMed

    Liu, Wenjie; Duan, Yuchen; Cui, Wenyao; Li, Li; Wang, Xia; Dai, Heling; You, Chao; Chen, Maojun

    2016-07-01

    To compare the efficacy of several antiseptics in decreasing the blood culture contamination rate. Network meta-analysis. Electronic searches of PubMed and Embase were conducted up to November 2015. Only randomized controlled trials or quasi-randomized controlled trials were eligible. We applied no language restriction. A comprehensive review of articles in the reference lists was also accomplished for possible relevant studies. Relevant studies evaluating efficacy of different antiseptics in venous puncture site for decreasing the blood culture contamination rate were included. The data were extracted from the included randomized controlled trials by two authors independently. The risk of bias was evaluated using Detsky scale by two authors independently. We used WinBUGS1.43 software and statistic model described by Chaimani to perform this network meta-analysis. Then graphs of statistical results of WinBUGS1.43 software were generated using 'networkplot', 'ifplot', 'netfunnel' and 'sucra' procedure by STATA13.0. Odds ratio and 95% confidence intervals were assessed for dichotomous data. A probability of p less than 0.05 was considered to be statistically significant. Compared with ordinary meta-analyses, this network meta-analysis offered hierarchies for the efficacy of different antiseptics in decreasing the blood culture contamination rate. Seven randomized controlled trials involving 34,408 blood samples were eligible for the meta-analysis. No significant difference was found in blood culture contamination rate among different antiseptics. No significant difference was found between non-alcoholic antiseptics and alcoholic antiseptics, alcoholic chlorhexidine and povidone iodine, chlorhexidine and iodine compounds, povidone iodine and iodine tincture in this aspect, respectively. Different antiseptics may not affect the blood culture contamination rate. Different intervals between the skin disinfection and the venous puncture, the different settings (emergency

  10. Venous pooling and drainage affects photoplethysmographic signals at different vertical hand positions

    NASA Astrophysics Data System (ADS)

    Hickey, Michelle; Phillips, Justin P.; Kyriacou, Panayiotis

    2015-03-01

    The aim of the current work is to investigate the possibility of augmenting pulse oximetry algorithms to enable the estimation of venous parameters in peripheral tissues. In order to further understand the contribution of venous blood to the photoplethysmographic (PPG) signal, recordings were made from six healthy volunteer subjects during an exercise in which the right hand was placed in various positions above and below heart level. The left hand was kept at heart level as a control while the right hand was moved. A custom-made two-channel dual wavelength PPG instrumentation system was used to obtain the red and infrared plethysmographic signals from both the right and left index fingers simultaneously using identical sensors. Laser Doppler flowmetry signals were also recorded from an adjacent fingertip on the right hand. Analysis of all acquired PPG signals indicated changes in both ac and dc amplitude of the right hand when the position was changed, while those obtained from the left (control) hand remained relatively constant. Most clearly, in the change from heart level to 50cm below heart level there is a substantial decrease in both dc and ac amplitudes. This decrease in dc amplitude most likely corresponds to increased venous pooling, and hence increased absorption of light. It is speculated that the decrease in ac PPG amplitude is due to reduced arterial emptying during diastole due to increased downstream resistance due to venous pooling.

  11. Combining image-derived and venous input functions enables quantification of serotonin-1A receptors with [carbonyl-11C]WAY-100635 independent of arterial sampling.

    PubMed

    Hahn, Andreas; Nics, Lukas; Baldinger, Pia; Ungersböck, Johanna; Dolliner, Peter; Frey, Richard; Birkfellner, Wolfgang; Mitterhauser, Markus; Wadsak, Wolfgang; Karanikas, Georgios; Kasper, Siegfried; Lanzenberger, Rupert

    2012-08-01

    image- derived input functions (IDIFs) represent a promising technique for a simpler and less invasive quantification of PET studies as compared to arterial cannulation. However, a number of limitations complicate the routine use of IDIFs in clinical research protocols and the full substitution of manual arterial samples by venous ones has hardly been evaluated. This study aims for a direct validation of IDIFs and venous data for the quantification of serotonin-1A receptor binding (5-HT(1A)) with [carbonyl-(11)C]WAY-100635 before and after hormone treatment. Fifteen PET measurements with arterial and venous blood sampling were obtained from 10 healthy women, 8 scans before and 7 after eight weeks of hormone replacement therapy. Image-derived input functions were derived automatically from cerebral blood vessels, corrected for partial volume effects and combined with venous manual samples from 10 min onward (IDIF+VIF). Corrections for plasma/whole-blood ratio and metabolites were done separately with arterial and venous samples. 5-HT(1A) receptor quantification was achieved with arterial input functions (AIF) and IDIF+VIF using a two-tissue compartment model. Comparison between arterial and venous manual blood samples yielded excellent reproducibility. Variability (VAR) was less than 10% for whole-blood activity (p>0.4) and below 2% for plasma to whole-blood ratios (p>0.4). Variability was slightly higher for parent fractions (VARmax=24% at 5 min, p<0.05 and VAR<13% after 20 min, p>0.1) but still within previously reported values. IDIFs after partial volume correction had peak values comparable to AIFs (mean difference Δ=-7.6 ± 16.9 kBq/ml, p>0.1), whereas AIFs exhibited a delay (Δ=4 ± 6.4s, p<0.05) and higher peak width (Δ=15.9 ± 5.2s, p<0.001). Linear regression analysis showed strong agreement for 5-HT(1A) binding as obtained with AIF and IDIF+VIF at baseline (R(2)=0.95), after treatment (R(2)=0.93) and when pooling all scans (R(2)=0.93), with slopes and

  12. Impact of Tissue Factor Localization on Blood Clot Structure and Resistance under Venous Shear.

    PubMed

    Govindarajan, Vijay; Zhu, Shu; Li, Ruizhi; Lu, Yichen; Diamond, Scott L; Reifman, Jaques; Mitrophanov, Alexander Y

    2018-02-27

    The structure and growth of a blood clot depend on the localization of tissue factor (TF), which can trigger clotting during the hemostatic process or promote thrombosis when exposed to blood under pathological conditions. We sought to understand how the growth, structure, and mechanical properties of clots under flow are shaped by the simultaneously varying TF surface density and its exposure area. We used an eight-channel microfluidic device equipped with a 20- or 100-μm-long collagen surface patterned with lipidated TF of surface densities ∼0.1 and ∼2 molecules/μm 2 . Human whole blood was perfused at venous shear, and clot growth was continually measured. Using our recently developed computational model of clot formation, we performed simulations to gain insights into the clot's structure and its resistance to blood flow. An increase in TF exposure area resulted not only in accelerated bulk platelet, thrombin, and fibrin accumulation, but also in increased height of the platelet mass and increased clot resistance to flow. Moreover, increasing the TF surface density or exposure area enhanced platelet deposition by approximately twofold, and thrombin and fibrin generation by greater than threefold, thereby increasing both clot size and its viscous resistance. Finally, TF effects on blood flow occlusion were more pronounced for the longer thrombogenic surface than for the shorter one. Our results suggest that TF surface density and its exposure area can independently enhance both the clot's occlusivity and its resistance to blood flow. These findings provide, to our knowledge, new insights into how TF affects thrombus growth in time and space under flow. Copyright © 2018 Biophysical Society. All rights reserved.

  13. Vascular Access Tracking System: a Web-Based Clinical Tracking Tool for Identifying Catheter Related Blood Stream Infections in Interventional Radiology Placed Central Venous Catheters.

    PubMed

    Morrison, James; Kaufman, John

    2016-12-01

    Vascular access is invaluable in the treatment of hospitalized patients. Central venous catheters provide a durable and long-term solution while saving patients from repeated needle sticks for peripheral IVs and blood draws. The initial catheter placement procedure and long-term catheter usage place patients at risk for infection. The goal of this project was to develop a system to track and evaluate central line-associated blood stream infections related to interventional radiology placement of central venous catheters. A customized web-based clinical database was developed via open-source tools to provide a dashboard for data mining and analysis of the catheter placement and infection information. Preliminary results were gathered over a 4-month period confirming the utility of the system. The tools and methodology employed to develop the vascular access tracking system could be easily tailored to other clinical scenarios to assist in quality control and improvement programs.

  14. Changes in blood velocity following microvascular free tissue transfer.

    PubMed

    Hanasono, Matthew M; Ogunleye, Olubunmi; Yang, Justin S; Hartley, Craig J; Miller, Michael J

    2009-09-01

    Understanding how pedicle blood velocities change after free tissue transfer may enable microvascular surgeons to predict when thrombosis is most likely to occur. A 20-MHz Doppler probe was used to measure arterial and venous blood velocities prior to pedicle division and 20 minutes after anastomosis in 32 microvascular free flaps. An implantable Doppler probe was then used to measure arterial and venous blood velocities daily for 5 days. Peak arterial blood velocity averaged 30.6 cm/s prior to pedicle division and increased to 36.5 cm/s 20 minutes after anastomosis ( P < 0.05). Peak venous blood velocity averaged 7.6 cm/s prior to pedicle division and increased to 12.4 cm/s 20 minutes after anastomosis ( P < 0.05). Peak arterial blood velocities averaged 34.0, 37.7, 43.8, 37.9, 37.6 cm/s on postoperative days (PODs) 1 through 5, respectively. Peak venous blood velocities averaged 11.9, 14.5, 18.2, 16.8, 17.7 cm/s on PODs 1 through 5, respectively. The peak arterial blood velocity on POD 3, and peak venous blood velocities on PODs 2, 3, and 5 were significantly higher than 20 minutes after anastomosis ( P < 0.05). Arterial and venous blood velocities increase for the first 3 postoperative days, potentially contributing to the declining risk for pedicle thrombosis during this time period.

  15. Filterability of freshly-collected sickle erythrocytes under venous oxygen pressure without exposure to air.

    PubMed

    Shah, Siddharth; Acholonu, Rhonda Graves; Ohene-Frempong, Kwaku; Asakura, Toshio

    2015-12-01

    We previously found that blood samples collected from steady-state patients with sickle cell disease (SCD) without exposure to air contain a new type of reversibly sickled cells (RSCs) with blunt edges at a level of as high as 78%. Since partial oxygenation of once-deoxygenated sickled cells with pointy edges to near venous oxygen pressure generates similar sickled cells with blunt edges in vitro, we named them as partially oxygenated sickled cells (POSCs). On the other hand, partial deoxygenation of once-oxygenated SS cells to venous oxygen pressure generates partially deoxygenated sickled cells (PDSCs) with pointy edges. In this study, we obtained blood samples from 6 steady-state patients with SCD under venous oxygen pressure without exposure to air, subjected them to various oxygenation/deoxygenation/reoxygenation cycles, and studied their filterability through a membrane filter with pore diameter of 3μm, the theoretical minimum diameter of a capillary. Our results indicated that discocytes, POSCs with blunt edges, and irreversibly sickled cells could deform and pass through the filter, while PDSCs with pointy edges were rigid and could not. The filterability of SS cells seems to be related to the length and amount of deoxy-hemoglobin S fibers in the cells. Copyright © 2015. Published by Elsevier Inc.

  16. Evaluation of venous distension device: potential aid for intravenous cannulation.

    PubMed

    Hedges, J R; Weinshenker, E; Dirksing, R

    1986-05-01

    A device designed to augment venous filling by applying a vacuum to the upper extremity during tourniquet application was evaluated. Ten healthy adult male volunteers with clinical normovolemia were studied for changes in forearm volume and dorsal hand vein turgor during use of an elastic tubing tourniquet, a blood pressure cuff tourniquet, and a vacuum-assisted cuff tourniquet. Use of the device for 30 seconds was not associated with petechia formation and resulted in a significant increase in venous turgor, as measured by an ophthalmologic tonometer, in comparison to the other tourniquet techniques (P less than .005). Use for 60 seconds was associated with mild to moderate subjective discomfort in all volunteers and petechiae in all nine white volunteers. All petechiae resolved in three days. Venous engorgement as reflected by volume displacement was significantly greater for the vacuum device and blood pressure cuff tourniquet combination than other techniques at 30 and 60 seconds of tourniquet application (P less than .005). Brief application of a vacuum to the arm during tourniquet use increases venous turgor and engorgement in normovolemic volunteers.

  17. Current concepts in repair of extremity venous injury.

    PubMed

    Williams, Timothy K; Clouse, W Darrin

    2016-04-01

    Extremity venous injury management remains controversial. The purpose of this communication is to offer perspective as well as experiential and technical insight into extremity venous injury repair. Available literature is reviewed and discussed. Historical context is provided. Indication, the decision process for repair, including technical conduct, is delineated. In particular, the authors' experiences in both civilian and wartime injury are used for perspective. Extremity venous injury repair was championed within data from the Vietnam Vascular Registry. However, patterns of extremity venous injury differ between combat and civilian settings. Since Vietnam, civilian descriptive series opine the benefits and potential complications associated with both venous injury repair and ligation. These surround extremity edema, chronic venous insufficiency, thromboembolism, and limb loss. Whereas no clear superiority in either approach has been identified to date, there appears to be no increased risk of pulmonary embolism or chronic venous changes with repair. Newer data from the wars in Iraq and Afghanistan and meta-analysis have reinforced this and also have suggested limb salvage benefit for extremity venous repair in combined arterial and venous injuries in modern settings. The patient's physiologic state and associated injury drive five triage categories suggesting vein injury management. Vein repair thrombosis occurs in a significant proportion, yet many recanalize and possibly have a positive impact on limb venous return. Further, early decompression favors reduced blood loss, acute edema, and inflammation, supporting collateral development. Large soft tissue injury minimizing collateral capacity increases the importance of repair. Constructs of repair are varied with modest differences in patency. Venous shunting is feasible, but specific roles remain nebulous. An aggressive posture toward extremity venous injury repair seems justified today because of the likely

  18. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  19. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  20. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  1. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  2. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  3. Early Detection and Quantification of Cerebral Venous Thrombosis by Magnetic Resonance Black Blood Thrombus Imaging (MRBTI)

    PubMed Central

    Yang, Qi; Duan, Jiangang; Fan, Zhaoyang; Qu, Xiaofeng; Xie, Yibin; Nguyen, Christopher; Du, Xiangying; Bi, Xiaoming; Li, Kuncheng; Ji, Xunming; Li, Debiao

    2015-01-01

    Background and Purpose Early diagnosis of cerebral venous and sinus thrombosis (CVT) is currently a major clinical challenge. We proposed a novel MR black-blood thrombus imaging technique(MRBTI) for detection and quantification of CVT. Methods MRBTI was performed on 23 patients with proven CVT and 24 patients with negative CVT confirmed by conventional imaging techniques. Patients were divided into two groups based on the duration of clinical onset: ≤ 7 days (group 1); between 7 and 30 days (group 2). Signal-to-noise ratio (SNR) was calculated for the detected thrombus and contrast-to-noise ratio (CNR) was measured between thrombus and lumen, and also between thrombus and brain tisssue. The feasibility of using MRBTI for thrombus volume measurement was explored and total thrombus volume was calculated for each patient. Results In 23 patients with proven CVT, MRBTI correctly identified 113 out of 116 segments with a sensitivity of 97.4%. Thrombus SNR was 153±57 and 261±95 for group 1(n=10) and group 2(n=13), respectively(P<0.01). Thrombus to lumen CNR was 149±57 and 256±94 for group 1 and group 2. Thrombus to brain tissue CNR was 41±36 and 120±63 (P<0.01), respectively. Quantification of thrombus volume was successfully conducted in all patients with CVT, and mean volume of thrombus was 10.5±6.9cc. Conclusions The current findings support that with effectively suppressed blood signal, MRBTI allows selective visualization of thrombus as opposed to indirect detection of venous flow perturbation and can be used as a promising first line diagnostic imaging tool. PMID:26670082

  4. Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle

    PubMed Central

    Li, Zhe; Baker, Wesley B.; Parthasarathy, Ashwin B.; Ko, Tiffany S.; Wang, Detian; Schenkel, Steven; Durduran, Turgut; Li, Gang; Yodh, Arjun G.

    2015-01-01

    Abstract. We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coefficient (γ) for the arm is determined, permitting conversion of DCS blood flow indices to absolute blood flow units, and a study of healthy adults (N=10) is carried out to ascertain the variability of γ. The average DCS calibration coefficient for the right (i.e., dominant) arm was γ=(1.24±0.15)×108 (mL·100  mL−1·min−1)/(cm2/s). However, variability can be significant and is apparent in our site-to-site and day-to-day repeated measurements. The peak hyperemic blood flow overshoot relative to baseline resting flow was also studied following arm-cuff ischemia; excellent agreement between VO-DOS and DCS was found (R2=0.95, slope=0.94±0.07, mean difference=−0.10±0.45). Finally, we show that incorporation of subject-specific absolute optical properties significantly improves blood flow calibration accuracy. PMID:26720870

  5. Venous flow during manual lymphatic drainage applied to different regions of the lower extremity in people with and without chronic venous insufficiency: a cross-sectional study.

    PubMed

    Crisóstomo, R S S; Candeias, M S; Armada-da-Silva, P A S

    2017-03-01

    To evaluate the effect of manual lymphatic drainage (MLD) on venous flow when applied to the medial and lateral aspects of the thigh and leg in patients with chronic venous insufficiency (CVI) and healthy subjects. Cross-sectional study. Participants were assessed in a school-based health community attendant service. Fifty-seven subjects participated in this study {mean age: 43 [standard deviation (SD) 14] years, 38 women and 19 men}. Of these, 28 subjects had CVI [mean age 47 (SD 12) years] and 29 subjects did not have CVI [mean age 39 (14) years]. MLD was applied by a certificated physical therapist to the medial and lateral aspects of the thigh and leg. Cross-sectional area; blood flow velocities in the femoral vein, great saphenous vein, popliteal vein and small saphenous vein at baseline and during MLD, measured by duplex ultrasound. Flow volume in the femoral vein increased from baseline [5.19 (SD 3.25)cm 3 /second] when MLD was applied to the medial [7.03 (SD 3.65)cm 3 /second; P≤0.001; mean difference -1.69; 95% confidence interval (CI) -2.42 to -0.97] and lateral [6.16 (SD 3.35)cm 3 /second; P≤0.001; mean difference -1.04; 95% CI -1.70 to -0.39] aspects of the thigh. Venous flow augmentation in the femoral vein and great saphenous vein was higher when MLD was applied to the medial aspect of the thigh (P<0.001), while MLD had a similar effect on venous blood flow regardless of whether it was applied to the medial or the lateral aspect of the leg (P=0.731). MLD increases blood flow in deep and superficial veins. MLD should be applied along the route of the venous vessels for improved venous return. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  6. Segmental Blood Flow and Hemodynamic State of Lymphedematous and Nonlymphedematous Arms

    PubMed Central

    Montgomery, Leslie D.; Dietrich, Mary S.; Armer, Jane M.; Stewart, B. R.

    2011-01-01

    Abstract Background Findings regarding the influence hemodynamic factors, such as increased arterial blood flow or venous abnormalities, on breast cancer treatment-related lymphedema are mixed. The purpose of this study was to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal individuals without lymphedema. Methods and Results A Tetrapolar High Resolution Impedance Monitor and Cardiotachometer were used to compare segmental arterial blood flow, venous blood return, and blood volumes between breast cancer survivors with treatment-related lymphedema and healthy normal volunteers. Average arterial blood flow in lymphedema-affected arms was higher than that in arms of healthy normal volunteers or in contralateral nonlymphedema affected arms. Time of venous outflow period of blood flow pulse was lower in lymphedema-affected arms than in healthy normal or lymphedema nonaffected arms. Amplitude of the venous component of blood flow pulse signal was lower in lymphedema-affected arms than in healthy or lymphedema nonaffected arms. Index of venular tone was also lower in lymphedema-affected arms than healthy or lymphedema nonaffected arms. Conclusions Both arterial and venous components may be altered in the lymphedema-affected arms when compared to healthy normal arms and contralateral arms in the breast cancer survivors. PMID:21417765

  7. The time-course of red blood cell intracellular pH recovery following short-circuiting in relation to venous transit times in rainbow trout, Oncorhynchus mykiss.

    PubMed

    Harter, Till Sebastian; May, Alexandra G; Federspiel, William J; Supuran, Claudiu T; Brauner, Colin J

    2018-04-11

    Accumulating evidence is highlighting the importance of a system of enhanced hemoglobin-oxygen (Hb-O 2 ) unloading for cardiovascular O 2 transport in teleosts. Adrenergically stimulated sodium-proton-exchangers (β-NHE) create H + gradients across the red blood cell (RBC) membrane that are short-circuited in the presence of plasma-accessible carbonic anhydrase (paCA) at the tissues; the result is a large arterial-venous pH shift that greatly enhances O 2 unloading from pH-sensitive Hb. However, RBC intracellular pH (pH i ) must recover during venous transit (31-90 s), to enable O 2 -loading at the gills. The halftimes (t 1/2 ) and magnitudes of RBC β-adrenergic stimulation, short-circuiting with paCA and recovery of RBC pH i , were assessed in vitro, on rainbow trout whole blood, and using changes in closed-system PO 2 as a sensitive indicator for changes in RBC pH i . In addition, the recovery rate of RBC pH i was assessed in a continuous-flow apparatus that more closely mimics RBC transit though the circulation. Results indicate that: i) the t 1/2 of CA short-circuiting is likely within the residence time of blood in the capillaries; ii) the t 1/2 of RBC pH i recovery is 17 s and within the time of RBC venous transit; and iii) after short-circuiting RBCs re-establish the initial H + gradient across the membrane and can potentially undergo repeated cycles of short-circuiting and recovery. Thus, teleosts have evolved a system that greatly enhances O 2 unloading from pH-sensitive Hb at the tissues, while protecting O 2 loading at the gills; the resulting increase in O 2 transport per unit of blood flow may enable the tremendous athletic ability of salmonids.

  8. Hepatic laceration as a life-threatening complication of umbilical venous catheterization.

    PubMed

    Gülcan, Hande; Hanta, Deniz; Törer, Birgin; Temiz, Adbülkerim; Demir, Senay

    2011-01-01

    Umbilical venous catheterization is an intravenous infusion route for maintenance fluids, medications, blood products, and parenteral nutrition in preterm neonates. However, this procedure may be associated with several complications, such as infection, thrombosis, vessel perforation, and cardiac and hepatic injuries. Hepatic laceration is a rare but life-threatening complication of umbilical venous catheterization that is a result of direct injury through the liver parenchyma. Here, we present a preterm newborn with hepatic laceration as a rare and serious complication of umbilical venous catheterization.

  9. Calf pump activity influencing venous hemodynamics in the lower extremity.

    PubMed

    Recek, Cestmir

    2013-03-01

    Calf muscle pump is the motive force enhancing return of venous blood from the lower extremity to the heart. It causes displacement of venous blood in both vertical and horizontal directions, generates ambulatory pressure gradient between thigh and lower leg veins, and bidirectional streaming within calf perforators. Ambulatory pressure gradient triggers venous reflux in incompetent veins, which induces ambulatory venous hypertension in the lower leg and foot. Bidirectional flow in calf perforators enables quick pressure equalization between deep and superficial veins of the lower leg; the outward (into the superficial veins) oriented component of the bidirectional flow taking place during calf muscle contraction is no pathological reflux but a physiological centripetal flow streaming via great saphenous vein into the femoral vein. Calf perforators are communicating channels between both systems making them conjoined vessels; they are not involved in the generation of pathological hemodynamic situations, nor do they cause ambulatory venous hypertension. The real cause why recurrences develop has not as yet been cleared. Pressure gradient arising during calf pump activity between the femoral vein and the saphenous remnant after abolition of saphenous reflux triggers biophysical and biochemical events, which might induce recurrence. Thus, abolition of saphenous reflux removes the hemodynamic disturbance, but at the same time it generates precondition for reflux recurrence and for the comeback of the previous pathological situation; this chain of events has been called hemodynamic paradox.

  10. Electrical foot stimulation and implications for the prevention of venous thromboembolic disease.

    PubMed

    Kaplan, Robert E; Czyrny, James J; Fung, Tat S; Unsworth, John D; Hirsh, Jack

    2002-08-01

    Venous stasis caused by immobility is an important risk factor for deep vein thrombosis following surgery and lower limb trauma, in bed-ridden medical patients, and in high-risk long distance air travelers. A safe and convenient method for reducing venous stasis would be useful in patients while in hospital and after discharge during their rehabilitation. 49 healthy subjects aged 51-76 were seated for 4 hours during which they received mild electrical stimulation of the calf, or sole of the foot (plantar muscles). Popliteal and femoral venous blood flow velocities were measured via doppler ultrasound. The non-stimulated lower extremity served as the simultaneous control. Subjects completed a questionnaire regarding their acceptance and tolerance of the electrical stimulation. There was a significant increase in venous femoral and popliteal blood flow for both calf (p < 0.035, p < 0.003), and plantar muscles (p < 0.0001, p < 0.009) on the stimulated side compared to the unstimulated side. The magnitude of the effect was similar for calf and plantar muscle stimulation. Subjects did not find the experience uncomfortable, and would use an electrical stimulator if told by their physician that they were at risk for developing blood clots. Mild electrical stimulation of the feet, as well as the calf, is a safe effective and convenient method for counteracting venous stasis and therefore has the potential to reduce the risk of deep vein thrombosis and pulmonary embolism for subjects who are immobilized.

  11. Venous levels of shear support neutrophil-platelet adhesion and neutrophil aggregation in blood via P-selectin and beta2-integrin

    NASA Technical Reports Server (NTRS)

    Konstantopoulos, K.; Neelamegham, S.; Burns, A. R.; Hentzen, E.; Kansas, G. S.; Snapp, K. R.; Berg, E. L.; Hellums, J. D.; Smith, C. W.; McIntire, L. V.; hide

    1998-01-01

    BACKGROUND: After activation, platelets adhere to neutrophils via P-selectin and beta2-integrin. The molecular mechanisms and adhesion events in whole blood exposed to venous levels of hydrodynamic shear in the absence of exogenous activation remain unknown. METHODS AND RESULTS: Whole blood was sheared at approximately 100 s(-1). The kinetics of neutrophil-platelet adhesion and neutrophil aggregation were measured in real time by flow cytometry. P-selectin was upregulated to the platelet surface in response to shear and was the primary factor mediating neutrophil-platelet adhesion. The extent of neutrophil aggregation increased linearly with platelet adhesion to neutrophils. Blocking either P-selectin, its glycoprotein ligand PSGL-1, or both simultaneously by preincubation with a monoclonal antibody resulted in equivalent inhibition of neutrophil-platelet adhesion (approximately 30%) and neutrophil aggregation (approximately 70%). The residual amount of neutrophil adhesion was blocked with anti-CD11b/CD18. Treatment of blood with prostacyclin analogue ZK36374, which raises cAMP levels in platelets, blocked P-selectin upregulation and neutrophil aggregation to baseline. Complete abrogation of platelet-neutrophil adhesion required both ZK36374 and anti-CD18. Electron microscopic observations of fixed blood specimens revealed that platelets augmented neutrophil aggregation both by forming bridges between neutrophils and through contact-mediated activation. CONCLUSIONS: The results are consistent with a model in which venous levels of shear support platelet adherence to neutrophils via P-selectin binding PSGL-1. This interaction alone is sufficient to mediate neutrophil aggregation. Abrogation of platelet adhesion and aggregation requires blocking Mac-1 in addition to PSGL-1 or P-selectin. The described mechanisms are likely of key importance in the pathogenesis and progression of thrombotic disorders that are exacerbated by leukocyte-platelet aggregation.

  12. Venous levels of shear support neutrophil-platelet adhesion and neutrophil aggregation in blood via P-selectin and beta2-integrin.

    PubMed

    Konstantopoulos, K; Neelamegham, S; Burns, A R; Hentzen, E; Kansas, G S; Snapp, K R; Berg, E L; Hellums, J D; Smith, C W; McIntire, L V; Simon, S I

    1998-09-01

    After activation, platelets adhere to neutrophils via P-selectin and beta2-integrin. The molecular mechanisms and adhesion events in whole blood exposed to venous levels of hydrodynamic shear in the absence of exogenous activation remain unknown. Whole blood was sheared at approximately 100 s(-1). The kinetics of neutrophil-platelet adhesion and neutrophil aggregation were measured in real time by flow cytometry. P-selectin was upregulated to the platelet surface in response to shear and was the primary factor mediating neutrophil-platelet adhesion. The extent of neutrophil aggregation increased linearly with platelet adhesion to neutrophils. Blocking either P-selectin, its glycoprotein ligand PSGL-1, or both simultaneously by preincubation with a monoclonal antibody resulted in equivalent inhibition of neutrophil-platelet adhesion (approximately 30%) and neutrophil aggregation (approximately 70%). The residual amount of neutrophil adhesion was blocked with anti-CD11b/CD18. Treatment of blood with prostacyclin analogue ZK36374, which raises cAMP levels in platelets, blocked P-selectin upregulation and neutrophil aggregation to baseline. Complete abrogation of platelet-neutrophil adhesion required both ZK36374 and anti-CD18. Electron microscopic observations of fixed blood specimens revealed that platelets augmented neutrophil aggregation both by forming bridges between neutrophils and through contact-mediated activation. The results are consistent with a model in which venous levels of shear support platelet adherence to neutrophils via P-selectin binding PSGL-1. This interaction alone is sufficient to mediate neutrophil aggregation. Abrogation of platelet adhesion and aggregation requires blocking Mac-1 in addition to PSGL-1 or P-selectin. The described mechanisms are likely of key importance in the pathogenesis and progression of thrombotic disorders that are exacerbated by leukocyte-platelet aggregation.

  13. Assessing vitamin D nutritional status: Is capillary blood adequate?

    PubMed

    Jensen, M E; Ducharme, F M; Théorêt, Y; Bélanger, A-S; Delvin, E

    2016-06-01

    Venous blood is the usual sample for measuring various biomarkers, including 25-hydroxyvitamin D (25OHD). However, it can prove challenging in infants and young children. Hence the finger-prick capillary collection is an alternative, being a relatively simple procedure perceived to be less invasive. We elected to validate the use of capillary blood sampling for 25OHD quantification by liquid chromatography tandem-mass spectrometry (LC/MS-MS). Venous and capillary blood samples were simultaneously collected from 15 preschool-aged children with asthma 10days after receiving 100,000IU of vitamin-D3 or placebo and 20 apparently healthy adult volunteers. 25OHD was measured by an in-house LC/MS-MS method. The venous 25OHD values varied between 23 and 255nmol/l. The venous and capillary blood total 25OHD concentrations highly correlated (r(2)=0.9963). The mean difference (bias) of capillary blood 25OHD compared to venous blood was 2.0 (95% CI: -7.5, 11.5) nmol/l. Our study demonstrates excellent agreement with no evidence of a clinically important bias between venous and capillary serum 25OHD concentrations measured by LC/MS-MS over a wide range of values. Under those conditions, capillary blood is therefore adequate for the measurement of 25OHD. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Comparison of intraosseous and infiltration injections for venous lidocaine blood concentrations and heart rate changes after injection of 2% lidocaine with 1:100,000 epinephrine.

    PubMed

    Wood, Mark; Reader, Al; Nusstein, John; Beck, Mike; Padgett, David; Weaver, Joel

    2005-06-01

    The purpose of this prospective, randomized study was to compare the venous blood levels of lidocaine and heart rate changes after intraosseous and infiltration injections of 1.8 ml of 2% lidocaine with 1:100,000 epinephrine. Using a crossover design, 20 subjects randomly received an intraosseous and infiltration injection at two separate appointments. The heart rate was measured using a pulse oximeter. Venous blood samples were collected before the injections and at 2, 5, 10, 15, 20, 25, 30, 45, and 60 min after the injections. The blinded plasma samples were analyzed for lidocaine concentrations using high-performance liquid chromatography (HPLC). The intraosseous injection resulted in a statistically significant increase in heart rate, when compared to the infiltration injection, during solution deposition and for 2 min after the injection. The plasma levels of lidocaine were not statistically different for maxillary anterior intraosseous and infiltration injections when using 1.8 ml of 2% lidocaine with 1:100,000 epinephrine.

  15. Postural Stability is Altered by Blood Shift

    NASA Astrophysics Data System (ADS)

    Marais, M.; Denise, P.; Guincetre, J. Y.; Normand, H.

    2008-06-01

    Non-vestibular influences as shift in blood volume changed perception of body posture. Then, factors affecting blood shift may alter postural control. The purpose of our study was to investigate the effects of leg venous contention on postural stability. Twelve subjects were studied on a balance plate for 5 minutes with the eyes closed, in 3 conditions: with no leg venous contention or grade 1 and 3 support stockings. Standard deviation of x and y position was calculated before and after the closure of the eyes. Strong venous contention altered postural stability, after the eyes were closed, during the first 10 s of standing. As support stockings prevent blood shift induced by upright posture, this result is in line with the hypothesis that blood shifts influence the perception of body orientation and postural control among others factors as vision, vestibular inputs... This strong venous contention could induce an increase of fall.

  16. Autotransfusion after total knee arthroplasty. Effects on blood cells, plasma chemistry, and whole blood rheology.

    PubMed

    Dalén, T; Broström, L A; Engström, K G

    1997-08-01

    Postoperative drain blood was collected and reinfused using the ConstaVac system (Stryker, Kalamazoo, MI) in 30 patients after total knee arthroplasty. Of the total 1.1-L volume of postoperative bleeding, 60% was reinfused. No clinical complications were observed. Differences between venous blood and drain blood and between venous blood and drain blood after separate incubation were studied with respect to acidic and inflammatory effects on blood cells, plasma chemistry, and whole blood rheology. In drain blood, leukocyte and platelet counts were reduced (P < .001), probably as a result of consumption in the wound. Acidic incubation occurs in the drain container because of production of lactate from glucose, with a minimum pH at 5 hours of 7.2. The low pH caused slight but significant erythrocyte swelling (P < .01). The complement C3d indicated leukocyte activation, although of modest magnitude. Despite incubation and complement activation, maximum erythrocyte hemolysis after 24 hours of incubation was less than 1%. Drain blood showed a lower resistance against micropore filtration than venous blood (P < .001), mainly because of the reduced number of leukocytes, and remained unchanged with incubation. Although the autotransfusion system can be improved with respect to blood quality, filtered drain blood should be considered acceptable for reinfusion.

  17. [Improving venous tone and capillary sealing. Effect of a combination of Ruscus extract and hesperidine methyl chalcone in healthy probands in heat stress].

    PubMed

    Rudofsky, G

    1989-06-30

    The drug combination of Ruscus-extract and hesperidine methyl chalcone (HMC) involves two basic mechanisms in the treatment of venous diseases: increase in venous tonicity and edema protection. This was shown in a double-blind study on 20 healthy volunteers by comparing the effectiveness of the individual substances, the combination and a placebo on the venous hemodynamics and the volume of the foot. Ruscus-extract augments the tonicity of the venous wall. This is expressed by a decrease in venous capacity (p less than 0.01), a reduction in the blood pool in the lower leg under orthostatic conditions, and a decrease in tissue volume of the foot and ankle (p less than 0.01). HMC lowers the capillary filtration rate (p less than 0.01) but augmented the blood pool. The increase in blood volume can be explained by dehydration of the tissue of the lower leg lowering the pressure of tissue on the venous system and increasing the blood pool in the limb. After administration of the combination, the blood volume was between the Ruscus and HMC volumes, while the effects on filtration rate, venous capacity and tissue volume corresponded to the changes seen after administration of HMC and Ruscus extract alone.

  18. Current challenges in diagnostic imaging of venous thromboembolism.

    PubMed

    Huisman, Menno V; Klok, Frederikus A

    2015-01-01

    Because the clinical diagnosis of deep-vein thrombosis and pulmonary embolism is nonspecific, integrated diagnostic approaches for patients with suspected venous thromboembolism have been developed over the years, involving both non-invasive bedside tools (clinical decision rules and D-dimer blood tests) for patients with low pretest probability and diagnostic techniques (compression ultrasound for deep-vein thrombosis and computed tomography pulmonary angiography for pulmonary embolism) for those with a high pretest probability. This combination has led to standardized diagnostic algorithms with proven safety for excluding venous thrombotic disease. At the same time, it has become apparent that, as a result of the natural history of venous thrombosis, there are special patient populations in which the current standard diagnostic algorithms are not sufficient. In this review, we present 3 evidence-based patient cases to underline recent developments in the imaging diagnosis of venous thromboembolism. © 2015 by The American Society of Hematology. All rights reserved.

  19. Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation

    PubMed Central

    Qureshi, M. Umar; Vaughan, Gareth D.A.; Sainsbury, Christopher; Johnson, Martin; Peskin, Charles S.; Olufsen, Mette S.; Hill, N.A.

    2014-01-01

    A novel multiscale mathematical and computational model of the pulmonary circulation is presented and used to analyse both arterial and venous pressure and flow. This work is a major advance over previous studies by Olufsen and coworkers (Ottesen et al., 2003; Olufsen et al., 2012) which only considered the arterial circulation. For the first three generations of vessels within the pulmonary circulation, geometry is specified from patient-specific measurements obtained using magnetic resonance imaging (MRI). Blood flow and pressure in the larger arteries and veins are predicted using a nonlinear, cross-sectional-area-averaged system of equations for a Newtonian fluid in an elastic tube. Inflow into the main pulmonary artery is obtained from MRI measurements, while pressure entering the left atrium from the main pulmonary vein is kept constant at the normal mean value of 2 mmHg. Each terminal vessel in the network of ‘large’ arteries is connected to its corresponding terminal vein via a network of vessels representing the vascular bed of smaller arteries and veins. We develop and implement an algorithm to calculate the admittance of each vascular bed, using bifurcating structured trees and recursion. The structured-tree models take into account the geometry and material properties of the ‘smaller’ arteries and veins of radii ≥ 50µm. We study the effects on flow and pressure associated with three classes of pulmonary hypertension expressed via stiffening of larger and smaller vessels, and vascular rarefaction. The results of simulating these pathological conditions are in agreement with clinical observations, showing that the model has potential for assisting with diagnosis and treatment of circulatory diseases within the lung. PMID:24610385

  20. Improved ex vivo blood compatibility of central venous catheter with noble metal alloy coating.

    PubMed

    Vafa Homann, Manijeh; Johansson, Dorota; Wallen, Håkan; Sanchez, Javier

    2016-10-01

    Central line associated bloodstream infections (CLABSIs) are a serious cause of morbidity and mortality induced by the use of central venous catheters (CVCs). Nobel metal alloy (NMA) coating is an advanced surface modification that prevents microbial adhesion and growth on catheters and thereby reduces the risk of infection. In vitro microbiological analyses have shown up to 90% reduction in microbial adhesion on coated CVC compared to uncoated ones. This study aimed to assess the blood compatibility of NMA-coated CVC according to ISO 10993-4. Hemolysis, thrombin-antithrombin (TAT) complex, platelet counts, fibrin deposition, and C3a and SC5b-9 complement activation were analyzed in human blood exposed to the NMA-coated and control CVCs using a Chandler-loop model. NMA-coated CVC did not induce hemolysis and fell in the "nonhemolytic" category according to ASTM F756-00. Significantly lower amounts of TAT were generated and less fibrin was deposited on NMA-coated CVC than on uncoated ones. Slightly higher platelet counts and lower complement markers were observed for NMA-coated CVC compared to uncoated ones. These data suggest that the NMA-coated CVC has better ex vivo blood compatibility compared to uncoated CVC. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1359-1365, 2016. © 2015 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  1. Some potential blood flow experiments for space

    NASA Technical Reports Server (NTRS)

    Cokelet, G. R.; Meiselman, H. J.; Goldsmith, H. L.

    1979-01-01

    Blood is a colloidal suspension of cells, predominantly erythrocytes, (red cells) in an aqueous solution called plasma. Because the red cells are more dense than the plasma, and because they tend to aggregate, erythrocyte sedimentation can be significant when the shear stresses in flowing blood are small. This behavior, coupled with equipment restrictions, has prevented certain definitive fluid mechanical studies from being performed with blood in ground-based experiments. Among such experiments, which could be satisfactorily performed in a microgravity environment, are the following: (1) studies of blood flow in small tubes, to obtain pressure-flow rate relationships, to determine if increased red cell aggregation can be an aid to blood circulation, and to determine vessel entrance lengths, and (2) studies of blood flow through vessel junctions (bifurcations), to obtain information on cell distribution in downstream vessels of (arterial) bifurcations, and to test flow models of stratified convergent blood flows downstream from (venous) bifurcations.

  2. Hydroperoxide in internal jugular venous blood reflects occurrence of subarachnoid hemorrhage-induced delayed cerebral vasospasm.

    PubMed

    Uekusa, Hiroyuki; Miyazaki, Chikao; Kondo, Kosuke; Harada, Naoyuki; Nomoto, Jun; Sugo, Nobuo; Nemoto, Masaaki

    2014-10-01

    To investigate the association between subarachnoid hemorrhage-induced delayed cerebral vasospasm (DCVS) and oxidative stress, an oxidation product, hydroperoxide, was measured in 3 specimens: peripheral arterial blood, cerebrospinal fluid (CSF), and internal jugular venous blood (IJVB). Hydroperoxide was measured using the diacron reactive oxygen metabolites (d-ROMs) test. The hydroperoxide levels were evaluated based on the rate of change in the d-ROMs test value on day 6 relative with that on day 3 (d-ROMs change rate). The subjects were 20 patients. The d-ROMs change rate in IJVB was significantly higher in patients with DCVS on day 6 than in those without it (P < .01). When the patients were classified into the following 3 groups: Group A (no DCVS occurred throughout the clinical course); Group B (DCVS occurred, but no cerebral infarction [CI] was induced); and Group C (DCVS occurred and caused CI), the d-ROMs change rate in IJVB was the highest in Group C, followed by Group B then A (P < .01). The d-ROMs change rates in peripheral arterial blood and CSF were not related to the development of DCVS. It was concluded that the more severe DCVS occurs and is more likely to progress to CI as the IJVB hydroperoxide level rises early after the development of subarachnoid hemorrhage. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  3. Variant adrenal venous anatomy in 546 laparoscopic adrenalectomies.

    PubMed

    Scholten, Anouk; Cisco, Robin M; Vriens, Menno R; Shen, Wen T; Duh, Quan-Yang

    2013-04-01

    Knowing the types and frequency of adrenal vein variants would help surgeons identify and control the adrenal vein during laparoscopic adrenalectomy. To establish the surgical anatomy of the main vein and its variants for laparoscopic adrenalectomy and to analyze the relationship between variant adrenal venous anatomy and tumor size, pathologic diagnosis, and operative outcomes. In a retrospective review of patients at a tertiary referral hospital, 506 patients underwent 546 consecutive laparoscopic adrenalectomies between April 22, 1993, and October 21, 2011. Patients with variant adrenal venous anatomy were compared with patients with normal adrenal venous anatomy regarding preoperative variables (patient and tumor characteristics [size and location] and clinical diagnosis), intraoperative variables (details on the main adrenal venous drainage, any variant venous anatomy, duration of operation, rate of conversion to hand-assisted or open procedure, and estimated blood loss), and postoperative variables (transfusion requirement, reoperation for bleeding, duration of hospital stay, and histologic diagnosis). Laparoscopic adrenalectomy. Prevalence of variant adrenal venous anatomy and its relationship to tumor characteristics, pathologic diagnosis, and operative outcomes. Variant venous anatomy was encountered in 70 of 546 adrenalectomies (13%). Variants included no main adrenal vein identifiable (n = 18), 1 main adrenal vein with additional small veins (n = 11), 2 adrenal veins (n = 20), more than 2 adrenal veins (n = 14), and variants of the adrenal vein drainage to the inferior vena cava and hepatic vein or of the inferior phrenic vein (n = 7). Variants occurred more often on the right side than on the left side (42 of 250 glands [17%] vs. 28 of 296 glands [9%], respectively; P = .02). Patients with variant anatomy compared with those with normal anatomy had larger tumors (mean, 5.1 vs 3.3 cm, respectively; P < .001), more pheochromocytomas (24 of 70 [35%] vs

  4. [Digital blood flow measurement by venous occlusion plethysmography in Raynaud's phenomenon. Value of the rewarming test].

    PubMed

    Cristol, R; Debray, J

    1986-01-01

    The fingertip blood flow measured by mercury strain gauge plethysmography with venous occlusion, at 22 degrees C room temperature, had significantly lower mean values in 190 patients with Raynaud's phenomenon (55 men aged 49 yrs +/- 16, 135 women aged 48 yrs +/- 16) than in 40 age and sex matched controls: 18 ml/100 ml/minute +/- 14.6 versus 35 ml/100 ml/minute +/- 15 at level p less than 0.01. The mean fingertip blood flow was significantly lower (p less than 0.01) in 31 cases of scleroderma and 32 cases of pulpar necrosis (respectively 13 ml +/- 13 and 11 ml +/- 8) than in 55 cases of primary Raynaud's disease (no detectable etiology and normal capillaroscopy 5 years after onset) or in 34 cases of mild Raynaud's phenomenon (respectively 21.6 +/- 16 and 24.4 +/- 18). A warming test (both hands in water at 45 degrees C during 3 minutes) was performed in 50 cases with low basal fingertip blood flow. It induced a "normalized" flow in 22 cases (mostly primary or mild Raynaud), a partly improved flow in 20 cases (mostly secondary Raynaud) and no improvement in 8 cases (scleroderma). The warming test appears to be clinically useful to assess the vasospasm and the vasodilating capabilities.

  5. Preoperative sclerotherapy of facial venous malformations: impact on surgical parameters and long-term follow-up.

    PubMed

    James, Charles A; Braswell, Leah E; Wright, Lonnie B; Roberson, Paula K; Moore, Mary B; Waner, Milton; Buckmiller, Lisa M

    2011-07-01

    To analyze the operative benefit of preoperative sclerotherapy of facial venous malformations and assess long-term patient outcome. Preoperative sclerotherapy was performed in 24 consecutive patients referred before resection of facial venous malformation. Pretreatment imaging was reviewed for malformation dimensions (length, width, and height), and volumes were estimated. Sclerotherapy was performed with 3% sodium tetradecyl in the first 15 patients and 98% dehydrated alcohol in the remaining 9 patients. Operative blood loss, operative time, transfusion requirement, and hospital stay were recorded. Operative time per lesion volume and operative blood loss per lesion volume were calculated. Results were compared with 15 historical control patients who underwent resection of facial venous malformations without preoperative sclerotherapy. Long-term follow-up of study and control patients was performed. Compared with controls, patients undergoing preoperative venous sclerotherapy were significantly older (P = .0206) and had larger lesions in all three dimensions (height, P = .0002; length, P = .0010; width, P = .0004). Patients receiving sclerotherapy had shorter operative time per lesion volume (P < .0001) and reduced blood loss per lesion volume (P < .0001). Neither hospital stay nor the need for blood transfusion differed from the control patients (P = .2449 and P = .6857). Mild periprocedural complications were encountered in 12.5% of cases, and nerve paresis occurred in 8.3% of cases. Long-term follow-up revealed retreatment was required in 2 of 24 patients (8.3%). Preoperative sclerotherapy of venous malformations was associated with less operative time per lesion volume and less operative blood loss per lesion volume. Long-term follow-up revealed a low need for retreatment. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  6. Renal and femoral venous blood flows are regulated by different mechanisms dependent on α-adrenergic receptor subtypes and nitric oxide in anesthetized rats.

    PubMed

    Fioretti, Alexandre C; Ogihara, Cristiana A; Cafarchio, Eduardo M; Venancio, Daniel P; de Almeida, Roberto Lopes; Antonio, Bruno B; Sato, Monica A

    2017-12-01

    Venous and arterial walls are responsive to sympathetic system and circulating substances, nevertheless, very few is known about the venous blood flow regulation simultaneously to arterial vascular beds. In this study, we compared the venous and arterial blood flow regulation in visceral and muscular beds upon injection of different doses of vasoactive drugs which act in arterial vascular beds. Anesthetized adult male Wistar rats underwent to right femoral artery and vein cannulation for hemodynamic recordings and infusion of drugs. Doppler flow probes were placed around the left renal artery and vein, and left femoral artery and vein to evaluate the changes in flood flow. Phenylephrine (PHE) injection (α 1 -adrenergic receptor agonist) elicited vasoconstriction in all arteries and veins. Intravenous prazosin (PZS) (1mg/kg, α 1 -adrenergic receptor blocker) caused renal artery vasodilation, but not in the other beds. Vasoconstrictor effect of PHE was abolished by PZS in all vascular beds, except in femoral vein. Phentolamine (PTL) injection (1mg/kg, α 1 /α 2 -adrenergic receptor blocker) produced renal artery vasodilation with no change in other beds. After PTL, the vasoconstriction evoked by PHE was abolished in all vascular beds. Sodium Nitroprusside (SNP), a nitric oxide donor, elicited vasodilation in all beds, and after PTL but not post PZS injection, SNP enhanced the vasodilatory effect in femoral vein. Our findings suggest that the vasoconstriction in renal and femoral veins is mediated by different subtypes of α-adrenoceptors. The nitric oxide-dependent vasodilation in femoral vein enhances when α 2 -adrenoceptors are not under stimulation, but not in the other vascular beds investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Transpulmonary passage of venous air emboli

    NASA Technical Reports Server (NTRS)

    Butler, B. D.; Hills, B. A.

    1985-01-01

    Twenty-seven paralyzed anesthetized dogs were embolized with venous air to determine the effectiveness of the pulmonary vasculature for bubble filtration or trapping. Air doses ranged from 0.05 to 0.40 ml/kg min in 0.05-ml increments with ultrasonic Doppler monitors placed over arterial vessels to detect any microbubbles that crossed the lungs. Pulmonary vascular filtration of the venous air infusions was complete for the lower air doses ranging from 0.05 to 0.30 ml/kg min. When the air doses were increased to 0.35 ml/kg min, the filtration threshold was exceeded with arterial spillover of bubbles occurring in 50 percent of the animals and reaching 71 percent for 0.40 ml/kg min. Significant elevations were observed in pulmonary arterial pressure and pulmonary vascular resistance. Systemic blood pressure and cardiac output decreased, whereas left ventricular end-diastolic pressure remained unchanged. The results indicate that the filtration of venous bubbles by the pulmonary vasculature was complete when the air infusion rates were kept below a threshold value of 0.30 ml/kg min.

  8. Preoperative Embolization of Venous Malformations Using n-Butyl Cyanoacrylate.

    PubMed

    Uller, Wibke; El-Sobky, Sherif; Alomari, Ahmad I; Fishman, Steven J; Spencer, Samantha A; Taghinia, Amir H; Chaudry, Gulraiz

    2018-05-01

    The purpose of this study was to evaluate the safety and efficacy of preoperative percutaneous n-butyl cyanoacrylate (nBCA) embolization of venous malformations in children. Clinical data were retrospectively reviewed in children who underwent embolization using nBCA followed by resection of venous malformations. A total of 17 embolizations were performed in 14 patients (9 females, mean age: 5.5 years; median age: 3 years; range 0.1-16 years). The venous malformations involved the lower extremity and the knee joint (n = 7), the trunk (n = 4), head and neck (n = 2), and hand (n = 1). n-Butyl cyanoacrylate was diluted with iodized oil at a ratio of 1:3 to 1:5. The mean and median volume of nBCA per procedure were 2.1 and 2 mL, respectively (range: 0.5-8 mL). There were no complications associated with the procedures. The mean and median time between final embolization and resection were 3.6 and 2 days, respectively. All children underwent successful resection of the symptomatic lesions. The estimated mean and median blood loss were 75 and 50 mL, respectively (range: 5-350 mL). The postprocedure course was uneventful, the days to discharge ranged between 1 and 6 days (mean 3 days). Initial results suggest that preoperative percutaneous n-butyl cyanoacrylate embolization of venous malformations is safe and effective in children, with the potential for minimizing blood loss and inpatient stay.

  9. Venous sinus occlusive disease: MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuh, W.T.C.; Simonson, T.M.; Tali, E.T.

    1994-02-01

    To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attention to mass effect, hemorrhage, and T2-weighted image abnormalities as well as to abnormal parenchymal, venous, or arterial enhancement after intravenous gadopentetate dimeglumine administration. Follow-up studies when available were evaluated for atrophy, infraction, chronic mass effect, and hemorrhage. Mass effect was present in 25 of 26more » patients. Eleven of the 26 had mass effect without abnormal signal on T2-weighted images. Fifteen patients had abnormal signal on T2-weighted images, but this was much less extensive than the degree of brain swelling in all cases. No patient showed abnormal parenchymal or arterial enhancement. Abnormal venous enhancement was seen in 10 of 13 patients who had contrast-enhanced studies. Intraparenchymal hemorrhage was seen in nine patients with high signal on T2-weighted images predominantly peripheral to the hematoma in eight. Three overall MR patterns were observed in acute sinus thrombosis: (1) mass effect without associated abnormal signal on T2-weighted images, (2) mass effect with associated abnormal signal on T2-weighted images and/or ventricular dilatation that may be reversible, and (3) intraparenchymal hematoma with surrounding edema. MR findings of venus sinus occlusive disease are different from those of arterial ischemia and may reflect different underlying pathophysiology. In venous sinus occlusive disease, the breakdown of the blood-brain barrier (vasogenic edema and abnormal parenchymal enhancement) does not always occur, and brain swelling can persist up to 2 years with or without abnormal signal on T2-weighted images. 34 refs., 5 figs.« less

  10. Preoperative Evaluation of Collateral Venous Anastomoses in Meningioma Involving Cerebral Venous Sinus by Susceptibility Weighted Imaging

    PubMed Central

    Wang, Qing; He, Jingzhen; Ma, Xiangxing

    2014-01-01

    Abstract Precise preoperative identification of the collateral venous anastomoses is critical for proper surgical management of patients with meningioma involving sinus. This study was to assess the feasibility of susceptibility weighted imaging (SWI) to delineate the collateral venous anastomoses before surgery. Twenty-five patients with meningiomas that were involved in sinuses underwent surgery and the collateral anastomoses were evaluated with SWI and phase-contrast magnetic resonance venography (MRV) before surgery. The results obtained with SWI were compared with those obtained with MRV. Intraoperative findings were used as the gold standard. By surgery, a total of 98 collateral anastomotic veins were identified in the 25 patients. SWI depicted 85 collateral anastomotic veins close to the meningioma with a sensitivity of 87%, whereas MRV showed 57 collateral anastomotic veins with a sensitivity of 58%. The detectability of collateral anastomotic veins in SWI images was superior to MRV. The results suggest that SWI is superior to MRV and could provide more reliable information on the collateral venous anastomoses in patients with meningioma. PMID:25501068

  11. [Port device central venous access in children with chronic renal disease--personal experience].

    PubMed

    Szczepańska, Maria; Szprynger, Krystyna; Stoksik, Piotr; Morawiec-Knysak, Aurelia; Adamczyk, Piotr; Ziora, Katarzyna; Oswiecimska, Joanna

    2006-01-01

    The application of central venous lines in children has been widely accepted in the case of pediatric cancer treatment. This is of particular importance when the treatment must be continued during the long period of time. The indication to long-term application of central venous lines became significantly frequent within last years. They are necessary in the treatment of chronic pediatric patients, in whom the central venous line allows continuous access for medication, parenteral rehydration, nutrition and frequent blood sampling. In the current study authors present their experience in subcutaneous port devices application in children with kidney disease. The case history data obtained from 8 children were retrospectively analysed. In these children subcutaneous port devices were applied for mean 26.7 months (totally 9 port devices). The mean age at the time of implantation was 2.2 years, and the mean body weight--10.6 kg. Peripheral venous access in all children was bad. In one child during the time of implantation the hematoma of coli and chest was present. Infectious complications connected with implanted port device were not detected. Thrombotic complications were present in 6 children with chronic renal failure--in 5 the lumen of port device has been successfully recanalysed, in 3 cases even several times. In 1 child the thrombus on the tip of central venous line was detected. In 2 children the removal of port device was necessary because of breakage of venous line and in the second case because of port device thrombosis. Two children died with functioning port device. The cause of death was not connected with implanted port device. The application of subcutaneous port devices definitely improved the comfort of treatment but was significantly associated with thrombotic complications. Infectious complications were not detected as compared to hematological group of patients.

  12. Dried Blood Spot RNA Transcriptomes Correlate with Transcriptomes Derived from Whole Blood RNA.

    PubMed

    Reust, Mary J; Lee, Myung Hee; Xiang, Jenny; Zhang, Wei; Xu, Dong; Batson, Tatiana; Zhang, Tuo; Downs, Jennifer A; Dupnik, Kathryn M

    2018-05-01

    Obtaining RNA from clinical samples collected in resource-limited settings can be costly and challenging. The goals of this study were to 1) optimize messenger RNA extraction from dried blood spots (DBS) and 2) determine how transcriptomes generated from DBS RNA compared with RNA isolated from blood collected in Tempus tubes. We studied paired samples collected from eight adults in rural Tanzania. Venous blood was collected on Whatman 903 Protein Saver cards and in tubes with RNA preservation solution. Our optimal DBS RNA extraction used 8 × 3-mm DBS punches as the starting material, bead beater disruption at maximum speed for 60 seconds, extraction with Illustra RNAspin Mini RNA Isolation kit, and purification with Zymo RNA Concentrator kit. Spearman correlations of normalized gene counts in DBS versus whole blood ranged from 0.887 to 0.941. Bland-Altman plots did not show a trend toward over- or under-counting at any gene size. We report a method to obtain sufficient RNA from DBS to generate a transcriptome. The DBS transcriptome gene counts correlated well with whole blood transcriptome gene counts. Dried blood spots for transcriptome studies could be an option when field conditions preclude appropriate collection, storage, or transport of whole blood for RNA studies.

  13. New findings on venous thrombogenesis

    PubMed Central

    Byrnes, James R.; Wolberg, Alisa S.

    2017-01-01

    Summary Venous thrombosis (VT) is the third most common cause of cardiovascular death worldwide. Complications from VT and pulmonary embolism are the leading cause of lost disability-adjusted life years. Risks include genetic (e.g., non-O blood group, activated protein C resistance, hyperprothrombinemia) and acquired (e.g., age, surgery, cancer, pregnancy, immobilisation, female hormone use) factors. Pathophysiologic mechanisms that promote VT are incompletely understood, but involve abnormalities in blood coagulability, vessel function, and flow (so-called Virchow’s Triad). Epidemiologic studies of humans, animal models, and biochemical and biophysical investigations have revealed contributions from extrinsic, intrinsic, and common pathways of coagulation, endothelial cells, leukocytes, red blood cells, platelets, cell-derived microvesicles, stasis-induced changes in vascular cells, and blood rheology. Knowledge of these mechanisms may yield new therapeutic targets. Characterisation of mechanisms that mediate VT formation and stability, particularly in aging, are needed to advance understanding of VT. PMID:27878206

  14. Correlation Between Pediatric Open Heart Surgery Outcomes and Arterial-mixed Venous Oxygen Saturation Differences.

    PubMed

    Samadi, Mahmood; Malaki, Majid; Ghaffari, Shamsi; Golshan Khalili, Roza

    2012-01-01

    Low Cardiac Output Syndrome (LCOS) contributes to postoperative morbidity and mortality. This article tries to find a predictive factor to interpret outcome after cardiac operation. In a cross-sectional study, 100 children with congenital heart disease undergoing cardiovascular surgery with cardiopulmonary bypass (CPB) without significant left-to-right shunt were selected. Arterial and central venous oxygen saturation values were measured via blood samples simultaneously obtained in 6-hr intervals for a total of 24-hr during postoperative period at hours 0, 6, 12, 18, and 24. Postoperative ventilation support (intubation period) and cardiovascular support were also obtained from the hospital records. Statistical analysis was later performed comparing the arterial-mixed venous oxygen saturation differences and durations of required ventilatory and cardiovascular support, both for the complicated and non-complicated patient groups. The data was processed with correlation Pearson and Mann-Whitney U tests in SPSS 15 software, P less than 0.05 was significant. Mortality following cardiac operation is 6% and complications may happen in 45% of the cases. The highest Arterial-mixed venous oxygen saturation difference occurred immediately post operation (up to 57%). These measures were high up to 18 hours in complicated and non-complicated groups (36% vs. 31% ; P< 0.05). This factor cannot predict prolongation of intubation period in patients (P > 0.05). Arterial-mixed venous oxygen saturation difference may be high as much as 57% or as low as 23%.These different measures, being higher up to 18 hours in complicated to non-complicated groups after 18 hours, can be related to tissue ischemia during surgery and cannot be discriminative.

  15. Lack of association between venous hemodynamics, venous morphology and the postthrombotic syndrome after upper extremity deep venous thrombosis.

    PubMed

    Czihal, M; Paul, S; Rademacher, A; Bernau, C; Hoffmann, U

    2015-03-01

    To explore the association of the postthrombotic syndrome with venous hemodynamics and morphological abnormalities after upper extremity deep venous thrombosis. Thirty-seven patients with a history of upper extremity deep venous thrombosis treated with anticoagulation alone underwent a single study visit (mean time after diagnosis: 44.4 ± 28.1 months). Presence and severity postthrombotic syndrome were classified according to the modified Villalta score. Venous volume and venous emptying were determined by strain-gauge plethysmography. The arm veins were assessed for postthrombotic abnormalities by ultrasonography. The relationship between postthrombotic syndrome and hemodynamic and morphological sequelae was evaluated using univariate significance tests and Spearman's correlation analysis. Fifteen of 37 patients (40.5%) developed postthrombotic syndrome. Venous volume and venous emptying of the arm affected by upper extremity deep venous thrombosis did not correlate with the Villalta score (rho = 0.17 and 0.19; p = 0.31 and 0.25, respectively). Residual morphological abnormalities, as assessed by ultrasonography, did not differ significantly between patients with and without postthrombotic syndrome (77.3% vs. 86.7%, p = 0.68). Postthrombotic syndrome after upper extremity deep venous thrombosis is not associated with venous hemodynamics or residual morphological abnormalities. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. [Participation of leucocytes in pathogenesis of primary forms of lower limb chronic venous disease].

    PubMed

    Bogachev, V Iu; Golovanova, O V; Sergeeva, N A; Kuznetsov, A N

    2011-01-01

    The purpose of the study was to test the hypothesis on participation of WBCs in damaging the venous wall in patients presenting with primary forms of lower limb chronic venous diseases LLCVD . The study included a total of fifteen consecutively selected patients (13 women and 2 men) diagnosed as having grade C2-C-4 LLCVD according to the CEAP classification. Static loading (30 minutes in the sitting position) was followed by simultaneous sampling of blood from the varicose vein of the cms and ulnar vein. The total blood count including determination of both the absolute values and percentage of blood formed elements was performed using the automated haematological counter «Advia 7» («Bayer», USA). The obtained findings were statistically processed using the Microsoft Office Excel software by means of the pared two-sample τ-test for the average values. The number of leukocytes and their subpopulations in blood samples obtained from the crural varicose veins turned out to be significantly less as compared with that in blood sampled from the ulnar vein. Thus, blood sampled from the crural varicose veins demonstrated a decrease in the counts of WBC by 9.6% in fourteen (93.3%) patients, that of neutrophils by 4.9% in twelve (80%) patients, that of lymphocytes by 16,8% in fifteen (100%) patients, and that oi monocytes by 24% in twelve (80%) patients. The mentioned differences were statistically significant at a = 0.05. The eosinophilic counts in blood sampled from the upper and lower extremities appeared similar in 66.7% of the examined subjects. In 33.3% of cases the eosinophilic count in blood samples from crural varicose vein was by 16.7% lower than that for blood samples form the ulnar vein. No differences for the rest parameters of the clinical blood count were revealed. The absolute lymphocytic count in the blood samples taken after the 30-minute static loading from the crural varicose veins was significantly lower as compared with that in blood sampled form

  17. Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in Humans

    NASA Technical Reports Server (NTRS)

    Watenpaugh, Donald E.

    1996-01-01

    Human venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is

  18. An affordable method to obtain cultured endothelial cells from peripheral blood

    PubMed Central

    Bueno-Betí, Carlos; Novella, Susana; Lázaro-Franco, Macarena; Pérez-Cremades, Daniel; Heras, Magda; Sanchís, Juan; Hermenegildo, Carlos

    2013-01-01

    The culture of endothelial progenitor cells (EPC) provides an excellent tool to research on EPC biology and vascular regeneration and vasculogenesis. The use of different protocols to obtain EPC cultures makes it difficult to obtain comparable results in different groups. This work offers a systematic comparison of the main variables of most commonly used protocols for EPC isolation, culture and functional evaluation. Peripheral blood samples from healthy individuals were recovered and mononuclear cells were cultured. Different recovery and culture conditions were tested: blood volume, blood anticoagulant, coating matrix and percentage of foetal bovine serum (FBS) in culture media. The success of culture procedure, first colonies of endothelial cells appearance time, correlation with number of circulating EPC (cEPC) and functional comparison with human umbilical vein endothelial cells (HUVEC) were studied. The use of heparin, a minimum blood volume of 30 ml, fibronectin as a coating matrix and endothelial growing media-2 supplemented with 20% FBS increased the success of obtaining EPC cultures up to 80% of the processed samples while reducing EPC colony appearance mean time to a minimum of 13 days. Blood samples exhibiting higher cEPC numbers resulted in reduced EPC colony appearance mean time. Cells isolated by using this combination were endothelial cell-like EPCs morphological and phenotypically. Functionally, cultured EPC showed decreased growing and vasculogenic capacity when compared to HUVEC. Thus, above-mentioned conditions allow the isolation and culture of EPC with smaller blood volumes and shorter times than currently used protocols. PMID:24118735

  19. Blood Pressure vs. Heart Rate

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 Understanding the difference ... your blood moving through your blood vessels, your heart rate is the number of times your heart beats ...

  20. Cord blood level of insulin-like growth factor-1 and IGF binding protein-3 in monochorionic twins.

    PubMed

    Teng, Ru-Jeng; Wu, Tzong-Jin; Hsieh, Fon-Jou

    2015-04-01

    Insulin-like growth factors (IGFs) and their binding proteins (IGFBPs) are known to modulate fetal growth but their role in intrauterine growth of monochorionic twins (MCT) has not been studied. Cord venous blood was collected directly after birth. IGF-1 and IGFBP-3 in the cord venous blood were quantified by radioimmunoassay. Birth weights (BWs) were obtained electronically. Placentas were examined for chorionicity. Cord blood was collected in 37 pairs of MCT (15 pairs were males). BWs ranged from 564 to 3240 g, and gestational ages (GAs) were between 24 weeks and 39 weeks. There was a correlation between BW and cord venous blood IGFBP-3 concentration (r = 0.28, p = 0.015), but not between BW and cord venous blood IGF-1 level. There was no difference in IGF-1 between the heavier twins (30.8 ± 61.8 ng/mL) and lighter twins (33.2 ± 63.7 ng/mL), but a trend (p = 0.096) of higher IGFBP-3 level was demonstrated in heavier twins (3.14 ± 1.23 μg/mL) than in lighter twins (2.71 ± 1.19 μg/mL). The IGFBP-3 levels were higher (p = 0.042) in female twins (3.20 ± 1.33 μg/mL) than in male twins (2.64 ± 1.04 μg/mL). The IGF-1 level of the heavier twins correlated significantly to their lighter co-twin (r = 0.73, p < 0.001). Our data showed that cord venous blood IGF-1 level might be controlled mainly by genetic factors. IGFBP-3 might play an important role in fetal growth. Copyright © 2013. Published by Elsevier B.V.

  1. Investigation of cerebral venous outflow in microgravity.

    PubMed

    Taibi, A; Gadda, G; Gambaccini, M; Menegatti, E; Sisini, F; Zamboni, P

    2017-10-31

    The gravitational gradient is the major component to face when considering the physiology of venous return, and there is a growing interest in understanding the mechanisms ensuring the heart filling, in the absence of gravity, for astronauts who perform long-term space missions. The purpose of the Drain Brain project was to monitor the cerebral venous outflow of a crew member during an experiment on the International Space Station (ISS), so as to study the compensatory mechanisms that facilitate this essential physiological action in subjects living in a microgravity environment. Such venous function has been characterized by means of a novel application of strain-gauge plethysmography which uses a capacitive sensor. In this contribution, preliminary results of our investigation have been presented. In particular, comparison of plethysmography data confirmed that long duration spaceflights lead to a redistribution of venous blood volume, and showed interesting differences in the amplitude of cardiac oscillations measured at the level of the neck veins. The success of the experiment has also demonstrated that thanks to its easy portability, non-invasiveness, and non-operator dependence, the proposed device can be considered as a novel tool for use aboard the ISS. Further trials are now under way to complete the investigation on the drainage function of the neck veins in microgravity.

  2. Central Venous Occlusion in the Hemodialysis Patient.

    PubMed

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  3. Factors Associated With Elevated Blood Lead Levels in Children.

    PubMed

    Chaudhary, Sakshi; Firdaus, Uzma; Ali, Syed Manazir; Mahdi, Abbas Ali

    2018-01-15

    To determine the prevalence and correlates of elevated blood lead level in children (6-144 months) of Aligarh. A hospital-based cross-sectional study was conducted. Venous blood was obtained for lead estimation and a structured questionnaire was filled. A total of 260 children were enrolled. The prevalence of elevated blood lead level was 44.2%, seen mostly in children below 5 years of age. Old and deteriorating wall paints at home was found to be significantly associated with elevated levels. Lead-based house paints are potential source of lead exposure. Meticulous renovation and painting of the walls with safe paints is desirable.

  4. The role of central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference as a goal and prognosis of sepsis treatment.

    PubMed

    Wittayachamnankul, Borwon; Chentanakij, Boriboon; Sruamsiri, Kamphee; Chattipakorn, Nipon

    2016-12-01

    The current practice in treatment of severe sepsis and septic shock is to ensure adequate oxygenation and perfusion in patients, along with prompt administration of antibiotics, within 6 hours from diagnosis, which is considered the "golden hour" for the patients. One of the goals of treatment is to restore normal tissue perfusion. With this goal in mind, some parameters have been used to determine the success of treatment and mortality rate; however, none has been proven to be the best predictor of mortality rate in sepsis patients. Despite growing evidence regarding the prognostic indicators for mortality in sepsis patients, inconsistent reports exist. This review comprehensively summarizes the reports regarding the frequently used parameters in sepsis including central venous oxygen saturation, blood lactate, and central venous-to-arterial carbon dioxide partial pressure difference, as prognostic indicators for clinical outcomes in sepsis patients. Moreover, consistent findings and inconsistent reports for their pathophysiology and the potential mechanisms for their use as well as their limitations in sepsis patients are presented and discussed. Finally, a schematic strategy for potential management and benefits in sepsis patients is proposed based upon these current available data. There is currently no ideal biomarker that can indicate prognosis, predict progression of the disease, and guide treatment in sepsis. Further studies are needed to be carried out to identify the ideal biomarker that has all the desired properties. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Usefulness of venous oxygen saturation in the jugular bulb for the diagnosis of brain death: report of 118 patients.

    PubMed

    Díaz-Regañón, Genaro; Miñambres, Eduardo; Holanda, Marisol; González-Herrera, Segundo; López-Espadas, Francisco; Garrido-Díaz, Carlos

    2002-12-01

    To assess the usefulness of venous oxygen saturation in the jugular bulb (SjO(2)) as a complementary test for the diagnosis of brain death. Prospective observational study. Polytrauma intensive care unit (ICU) of an acute-care teaching hospital in Santander, Spain. We studied 118 (44%) out of 270 patients with severe head injury and intracranial hemorrhage meeting criteria of brain death (lack of cardiac response to atropine, unresponsive apnea, and iso-electric EEG in the absence of shock, hypotension and treatment with muscle relaxants and/or central nervous system (CNS) depressant drugs). At the moment at which clinical diagnosis of brain death was made and an iso-electric EEG was obtained, simultaneous oxygen saturation in central venous blood (right atrium) (SvO(2)) and jugular venous bulb (SjO(2)) samples was measured. The ratio between SvO(2) and SjO(2), expressed as CvjO(2) (the so-called central venous-jugular bulb oxygen saturation rate; CvjO(2) = SvO(2)/SjO(2)) was calculated. CvjO(2) less than 1 was obtained in 114 patients [mean (SD): 0.89 (0.02)], whereas CvjO(2) greater than 1 was obtained in only 4 (3.38%). In the group of 152 survivors, a single patient was discharged from the ICU in a vegetative state in which CvjO(2) was below 1. CvjO(2)as a complementary test for the diagnosis of brain death showed 96.6% sensitivity, 99.3% specificity, and 99.1% and 97.4% positive and negative predictive values, respectively. Central venous-jugular bulb oxygen saturation rate below 1 together with accepted clinical criteria (unresponsive coma with brainstem areflexia) provides non-invasive assessment of cerebral circulatory arrest that can help to suspect brain death.

  6. Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.

    PubMed

    Schallom, Marilyn E; Prentice, Donna; Sona, Carrie; Micek, Scott T; Skrupky, Lee P

    2012-06-01

    To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. Single-center, randomized, open label trial. Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential

  7. Understanding Blood Pressure Readings

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Understanding Blood Pressure Readings Updated:Jun 1,2018 What do your blood ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, ...

  8. Commercial Hy-Line W-36 pullet and laying hen venous blood gas and chemistry profiles utilizing the portable i-STAT®1 analyzer.

    PubMed

    Schaal, T P; Arango, J; Wolc, A; Brady, J V; Fulton, J E; Rubinoff, I; Ehr, I J; Persia, M E; O'Sullivan, N P

    2016-02-01

    Venous blood gas and chemistry reference ranges were determined for commercial Hy-Line W-36 pullets and laying hens utilizing the portable i-STAT®1 analyzer and CG8+ cartridges. A total of 632 samples were analyzed from birds between 4 and 110 wk of age. Reference ranges were established for pullets (4 to 15 wk), first cycle laying hens (20 to 68 wk), and second cycle (post molt) laying hens (70 to 110 wk) for the following traits: sodium (Na mmol/L), potassium (K mmol/L), ionized calcium (iCa mmol/L), glucose (Glu mg/dl), hematocrit (Hct% Packed Cell Volume [PCV]), pH, partial pressure carbon dioxide (PCO2 mm Hg), partial pressure oxygen (PO2 mm Hg), total concentration carbon dioxide (TCO2 mmol/L), bicarbonate (HCO3 mmol/L), base excess (BE mmol/L), oxygen saturation (sO2%), and hemoglobin (Hb g/dl). Data were analyzed using ANOVA to investigate the effect of production status as categorized by bird age. Trait relationships were evaluated by linear correlation and their spectral decomposition. All traits differed significantly among pullets and mature laying hens in both first and second lay cycles. Levels for K, iCa, Hct, pH, TCO2, HCO3, BE, sO2, and Hb differed significantly between first cycle and second cycle laying hens. Many venous blood gas and chemistry parameters were significantly correlated. The first 3 eigenvalues explained ∼2/3 of total variation. The first 2 principal components (PC) explained 51% of the total variation and indicated acid-balance and relationship between blood O2 and CO2. The third PC explained 16% of variation and seems to be related to blood iCa. Establishing reference ranges for pullet and laying hen blood gas and chemistry with the i-STAT®1 handheld unit provides a mechanism to further investigate pullet and layer physiology, evaluate metabolic disturbances, and may potentially serve as a means to select breeder candidates with optimal blood gas or chemistry levels on-farm. © The Author 2015. Published by Oxford University

  9. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    PubMed

    O'Connor, T M; Barry, P J; Jahangir, A; Finn, C; Buckley, B M; El-Gammal, A

    2011-01-01

    Arterial blood gases (ABGs) are often sampled incorrectly, leading to a 'mixed' or venous sample. Delays in analysis and air contamination are common. We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. Mean venous pH was 7.371 and arterial pH was 7.407 (p < 0.0001). There was a correlation between venous and arterial pH (r = 0.5347, p < 0.0001). The regression equation to predict arterial pH was: arterial pH = 4.2289 + 0.43113 · venous pH. There were no clinically significant differences in arterial PO₂ associated with analysis delay. A statistically significant decline in pH was detected at 30 min in patients with COPD exacerbation (p = 0.0042) and 90 min in controls (p < 0.0001). A clinically significant decline in pH emerged at 73 min in patients with COPD exacerbation and 87 min in controls. Air contamination was associated with a clinically significant increase in PO₂ in all samples, including those that were immediately analyzed. Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO₂, indicating that air-contaminated ABGs should be discarded. Copyright © 2010 S. Karger AG, Basel.

  10. Population-based screening for anemia using first-time blood donors

    PubMed Central

    Mast, Alan E.; Steele, Whitney R.; Johnson, Bryce; Wright, David J.; Cable, Ritchard G.; Carey, Patricia; Gottschall, Jerome L.; Kiss, Joseph E.; Simon, Toby L.; Murphy, Edward L.

    2012-01-01

    Background Anemia is an important public health concern. Data from population-based surveys such as the National Health and Nutrition Examination Survey (NHANES) are the gold standard, but are obtained infrequently and include only small samples from certain minority groups. Objectives We assessed whether readily available databases of blood donor hemoglobin values could be used as a surrogate for population hemoglobin values from NHANES. Design Blood donor venous and fingerstick hemoglobin values were compared to 10,254 NHANES 2005-2008 venous hemoglobin values using demographically stratified analyses and ANOVA. Fingerstick hemoglobins or hematocrits were converted to venous hemoglobin estimates using regression analysis. Results Venous hemoglobin values from 1,609 first time donors correlated extremely well with NHANES data across different age, gender and demographic groups. Cigarette smoking increased hemoglobin by 0.26 to 0.59 g/dL depending on intensity. Converted fingerstick hemoglobin from 36,793 first time donors agreed well with NHANES hemoglobin (weighted mean hemoglobin of 15.53 g/dL for donors and 15.73 g/dL for NHANES) with similar variation in mean hemoglobin by age. However, compared to NHANES, the larger donor dataset showed reduced differences in mean hemoglobin between Blacks and other races/ethnicities. Conclusions Overall, first-time donor fingerstick hemoglobins approximate U.S. population data and represent a readily available public health resource for ongoing anemia surveillance. PMID:22460662

  11. Preliminary clinical investigations of a new noninvasive venous pulse oximeter

    NASA Astrophysics Data System (ADS)

    Chan, Daniel; Smith, Peter R.; Caine, Michael P.; Spyt, Tomasz; Boehm, Maria; Machin, David

    2003-10-01

    For decades, the monitoring of mixed venous oxygen saturation, SvO2 has been performed invasively using fibre-optic catheters. This procedure is not without risk as complications may arise from catheterisation. The group has devised a new non-invasive venous oximetry method which involves inducing regular modulations of the venous blood volume and associated measurement of those modulations using optical means. A clinical investigation was conducted in Glenfield Hospital, UK to evaluate the sensitivity of the new technique to haemodynamic changes such as Cardiac Output (CO) in intraoperative and postoperative cardiac patients. Preliminary trials on patients recovering from cardiac surgery yielded an average correlation of r = 0.72 between CO at different Intra Aortic Balloon Pump (IABP) augmentation levels and SvO2 measured by the new venous oximeter. In intraoperative patients undergoing off-pump cardiac surgery, SvO2 recorded by the new technique responded to unplanned events such as a cardiac arrest. CONCLUSION: The new venous oximetry technique is a promising technique which responds to haemodynamic changes such as CO and with further development might offer an alternative means of monitoring SvO2 non-invasively.

  12. Competing risk of atherosclerotic risk factors for arterial and venous thrombosis in a general population: the Tromso study.

    PubMed

    Brækkan, Sigrid K; Hald, Erin M; Mathiesen, Ellisiv B; Njølstad, Inger; Wilsgaard, Tom; Rosendaal, Frits R; Hansen, John-Bjarne

    2012-02-01

    To investigate and compare the impact of traditional atherosclerotic risk factors for the risk of arterial and venous thrombosis, taking into account competing risks. In 1994-1995, 26,185 subjects were screened in the Tromsø study. Information on traditional atherosclerotic risk factors was obtained by physical examination, blood samples, and questionnaires. Subjects were followed to the first incident event of myocardial infarction (MI) or venous thromboembolism (VTE), or December 31, 2005. During a median of 10.8 years of follow-up, there were 1279 cases of incident MI and 341 VTE events. Advancing age and high body mass index were both associated with MI and VTE. Hazard ratio per decade of age was 2.34 (95% CI: 2.25-2.43) for MI and 1.87 (1.74-2.01) for VTE, and 3 kg/m(2) increase in body mass index was associated with 1.16 (1.11-1.21) and 1.20 (1.12-1.29) increased risk of MI and VTE, respectively. Blood pressure, high levels of triglycerides and total cholesterol, low HDL cholesterol, self-reported diabetes, and smoking were all associated with increased risk of MI but not associated with VTE. Our findings imply that traditional atherosclerotic risk factors, such as smoking, hypertension, dyslipidemia, and diabetes mellitus are not shared by arterial and venous thrombosis.

  13. Forearm vasodilatation following release of venous congestion

    PubMed Central

    Caro, C. G.; Foley, T. H.; Sudlow, M. F.

    1970-01-01

    1. The volume rate of forearm blood flow was measured with a mercury-in-rubber strain gauge, or with a water-filled plethysmograph, from 1 sec after termination of a 2-3 min period of venous congestion. 2. When congesting pressure had been less than 18 mm Hg, average post-congestion flow (five subjects) was constant during approx. 10 sec and not significantly different from resting flow. 3. When congesting pressure had been 30 mm Hg, average post-congestion flow (eight subjects) was 26% higher than resting, during 3-4 sec after release of congestion, but rose to 273% of resting during 4-6 sec after release of congestion. 4. In other studies forearm vascular resistance had been found normal or increased during such venous congestion, and theoretical studies here indicated that passive mechanical factors could not account for the delayed occurrence of high post-congestion flow. 5. It appears, therefore, that the forearm vascular bed dilates actively shortly after release of substantial venous congestion. It would seem more likely that a myogenic mechanism, rather than a metabolic one, is responsible. PMID:5532541

  14. Noninvasive measurement of central venous pressure

    NASA Technical Reports Server (NTRS)

    Webster, J. G.; Mastenbrook, S. M., Jr.

    1972-01-01

    A technique for the noninvasive measurement of CVP in man was developed. The method involves monitoring venous velocity at a point in the periphery with a transcutaneous Doppler ultrasonic velocity meter while the patient performs a forced expiratory maneuver. The idea is the CVP is related to the value of pressure measured at the mouth which just stops the flow in the vein. Two improvements were made over the original procedure. First, the site of venous velocity measurement was shifted from a vein at the antecubital fossa (elbow) to the right external jugular vein in the neck. This allows for sensing more readily events occurring in the central veins. Secondly, and perhaps most significantly, a procedure for obtaining a curve of relative mean venous velocity vs mouth pressure was developed.

  15. Development and testing of an artificial arterial and venous pulse oximeter.

    PubMed

    Cloete, G; Fourie, P R; Scheffer, C

    2013-01-01

    The monitoring of patients healthcare is of a prime importance to ensure their efficient and effective treatment. Monitoring blood oxygen saturation is a field which has grown significantly in recent times and more specifically in tissues affected by diseases or conditions that may negatively affect the function of the tissue. This study involved the development and testing of a highly sensitive non-invasive blood oxygen saturation monitoring device. A device that can be used to continuously monitor the condition of tissue affected by diseases which affect the blood flow through the tissue, and the oxygen usage in tissue. The device's system was designed to specifically monitor occluded tissue which has low oxygen saturations and low perfusion. Although with limitted validation the system was unable to accurately measure the venous oxygenation specifically, but it was able to measure the mixed oxygen saturation. With further research it would be possible to validate the system for measuring both the arterial and venous oxygen saturations.

  16. Evaluation of four rapid methods for hemoglobin screening of whole blood donors in mobile collection settings.

    PubMed

    Gómez-Simón, Antonia; Navarro-Núñez, Leyre; Pérez-Ceballos, Elena; Lozano, María L; Candela, María J; Cascales, Almudena; Martínez, Constantino; Corral, Javier; Vicente, Vicente; Rivera, José

    2007-06-01

    Predonation hemoglobin measurement is a problematic requirement in mobile donation settings, where accurate determination of venous hemoglobin by hematology analyzers is not available. We have evaluated hemoglobin screening in prospective donors by the semiquantitative copper sulphate test and by capillary blood samples analyzed by three portable photometers, HemoCue, STAT-Site MHgb, and the CompoLab HB system. Capillary blood samples were obtained from 380 donors and tested by the copper sulphate test and by at least one of the named portable photometers. Predonation venous hemoglobin was also determined in all donors using a Coulter Max-M analyzer. The three photometers provided acceptable reproducibility (CV below 5%), and displayed a significant correlation between the capillary blood samples and the venous hemoglobin (R2 0.5-0.8). HemoCue showed the best agreement with venous hemoglobin determination, followed by STAT-Site MHgb, and the CompoLab HB system. The copper sulphate test provided the highest rate of donors acceptance (83%) despite unacceptable hemoglobin levels, and the lowest rate for donor deferral (1%) despite acceptable hemoglobin levels. The percentage of donors correctly categorized for blood donation by the portable hemoglobinometers was 85%, 82%, and 76% for CompoLab HB system, HemoCue and STAT-Site, respectively. Our data suggest that hemoglobin determination remains a conflictive issue in donor selection in the mobile setting. Without appropriate performance control, capillary hemoglobin screening by either the copper sulphate method or by the novel portable hemoglobinometers could be inaccurate, thus potentially affecting both donor safety and the blood supply.

  17. Proof of concept non-invasive estimation of peripheral venous oxygen saturation.

    PubMed

    Khan, Musabbir; Pretty, Chris G; Amies, Alexander C; Balmer, Joel; Banna, Houda E; Shaw, Geoffrey M; Geoffrey Chase, J

    2017-05-19

    Pulse oximeters continuously monitor arterial oxygen saturation. Continuous monitoring of venous oxygen saturation (SvO 2 ) would enable real-time assessment of tissue oxygen extraction (O 2 E) and perfusion changes leading to improved diagnosis of clinical conditions, such as sepsis. This study presents the proof of concept of a novel pulse oximeter method that utilises the compliance difference between arteries and veins to induce artificial respiration-like modulations to the peripheral vasculature. These modulations make the venous blood pulsatile, which are then detected by a pulse oximeter sensor. The resulting photoplethysmograph (PPG) signals from the pulse oximeter are processed and analysed to develop a calibration model to estimate regional venous oxygen saturation (SpvO 2 ), in parallel to arterial oxygen saturation estimation (SpaO 2 ). A clinical study with healthy adult volunteers (n = 8) was conducted to assess peripheral SvO 2 using this pulse oximeter method. A range of physiologically realistic SvO 2 values were induced using arm lift and vascular occlusion tests. Gold standard, arterial and venous blood gas measurements were used as reference measurements. Modulation ratios related to arterial and venous systems were determined using a frequency domain analysis of the PPG signals. A strong, linear correlation (r 2  = 0.95) was found between estimated venous modulation ratio (R Ven ) and measured SvO 2 , providing a calibration curve relating measured R Ven to venous oxygen saturation. There is a significant difference in gradient between the SpvO 2 estimation model (SpvO 2  = 111 - 40.6*R) and the empirical SpaO 2 estimation model (SpaO 2  = 110 - 25*R), which yields the expected arterial-venous differences. Median venous and arterial oxygen saturation accuracies of paired measurements between pulse oximeter estimated and gold standard measurements were 0.29 and 0.65%, respectively, showing good accuracy of the pulse oximeter system

  18. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.

    Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. Amore » combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically

  19. Pentoxifylline for treating venous leg ulcers.

    PubMed

    Jull, Andrew B; Arroll, Bruce; Parag, Varsha; Waters, Jill

    2012-12-12

    Healing of venous leg ulcers is improved by the use of compression bandaging but some venous ulcers remain unhealed, and some people are unsuitable for compression therapy. Pentoxifylline, a drug which helps blood flow, has been used to treat venous leg ulcers. To assess the effects of pentoxifylline (oxpentifylline or Trental 400) for treating venous leg ulcers, compared with a placebo or other therapies, in the presence or absence of compression therapy. For this fifth update we searched the Cochrane Wounds Group Specialised Register (searched 20 July 2012); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 7); Ovid MEDLINE (2010 to July Week 2 2012); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, July 19, 2012); Ovid EMBASE (2010 to 2012 Week 28); and EBSCO CINAHL (2010 to July 13 2012). Randomised trials comparing pentoxifylline with placebo or other therapy in the presence or absence of compression, in people with venous leg ulcers. One review author extracted and summarised details from eligible trials using a coding sheet. One other review author independently verified data extraction. No new trials were identified for this update. We included twelve trials involving 864 participants. The quality of trials was variable. Eleven trials compared pentoxifylline with placebo or no treatment. Pentoxifylline is more effective than placebo in terms of complete ulcer healing or significant improvement (RR 1.70, 95% CI 1.30 to 2.24). Pentoxifylline plus compression is more effective than placebo plus compression (RR 1.56, 95% CI 1.14 to 2.13). Pentoxifylline in the absence of compression appears to be more effective than placebo or no treatment (RR 2.25, 95% CI 1.49 to 3.39).More adverse effects were reported in people receiving pentoxifylline (RR 1.56, 95% CI 1.10 to 2.22). Nearly three-quarters (72%) of the reported adverse effects were gastrointestinal. Pentoxifylline is an effective adjunct to compression

  20. Estrogen Receptors and Chronic Venous Disease.

    PubMed

    Serra, R; Gallelli, L; Perri, P; De Francesco, E M; Rigiracciolo, D C; Mastroroberto, P; Maggiolini, M; de Franciscis, S

    2016-07-01

    Chronic venous disease (CVD) is a common and relevant problem affecting Western people. The role of estrogens and their receptors in the venous wall seems to support the major prevalence of CVD in women. The effects of the estrogens are mediated by three estrogen receptors (ERs): ERα, ERβ, and G protein-coupled ER (GPER). The expression of ERs in the vessel walls of varicose veins is evaluated. In this prospective study, patients of both sexes, with CVD and varicose veins undergoing open venous surgery procedures, were enrolled in order to obtain vein samples. To obtain control samples of healthy veins, patients of both sexes without CVD undergoing coronary artery bypass grafting with autologous saphenous vein were recruited (control group). Samples were processed in order to evaluate gene expression. Forty patients with CVD (10 men [25%], 30 women [75%], mean age 54.3 years [median 52 years, range 33-74 years]) were enrolled. Five patients without CVD (three men, two women [aged 61-73 years]) were enrolled as the control group. A significant increase of tissue expression of ERα, ERβ and GPER in patients with CVD was recorded (p < .01), which was also related to the severity of venous disease. ERs seem to play a role in CVD; in this study, the expression of ERs correlated with the severity of the disease, and their expression was correlated with the clinical stage. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. A postscript to Circulation of the blood: men and ideas.

    PubMed

    Riley, R L

    1982-10-01

    Since 1964, when Fishman and Richards published Circulation of the Blood: Men and Ideas, Guyton's model of the circulation, in which mean circulatory pressure serves as the upstream pressure for venous return, has been extended, and the concept of vascular smooth muscle tone acting like the pressure surrounding a Starling resistor has been postulated. According to this scheme, the positive zero flow intercepts of rapidly determined arterial pressure-flow curves are the effective downstream pressures for arterial flow to different tissues. The arterioles, like Starling resistors, determine the downstream pressures and are followed by abrupt pressure drops, or "waterfalls." Capillary pressures are closely linked to those of the venules into which they flow. Capillary-venular pressures are the upstream pressures for venous return. In exercising muscles, reduced arteriolar tone lowers arteriolar pressure and increases arterial flow. This, in turn, raises capillary-venular pressure and increases venous flow. The arteriolar-capillary waterfall is decreased or eliminated. Total blood flow is increased by diversion of blood from tissues with slow venous drainage to muscles with fast venous drainage (low resistance X compliance). The heart pumps away the increased venous return by shifting to a new ventricular function curve.

  2. Congestive renal failure: the pathophysiology and treatment of renal venous hypertension.

    PubMed

    Ross, Edward A

    2012-12-01

    Longstanding experimental evidence supports the role of renal venous hypertension in causing kidney dysfunction and "congestive renal failure." A focus has been heart failure, in which the cardiorenal syndrome may partly be due to high venous pressure, rather than traditional mechanisms involving low cardiac output. Analogous diseases are intra-abdominal hypertension and renal vein thrombosis. Proposed pathophysiologic mechanisms include reduced transglomerular pressure, elevated renal interstitial pressure, myogenic and neural reflexes, baroreceptor stimulation, activation of sympathetic nervous and renin angiotensin aldosterone systems, and enhanced proinflammatory pathways. Most clinical trials have addressed the underlying condition rather than venous hypertension per se. Interpreting the effects of therapeutic interventions on renal venous congestion are therefore problematic because of such confounders as changes in left ventricular function, cardiac output, and blood pressure. Nevertheless, there is preliminary evidence from small studies of intense medical therapy or extracorporeal ultrafiltration for heart failure that there can be changes to central venous pressure that correlate inversely with renal function, independently from the cardiac index. Larger more rigorous trials are needed to definitively establish under what circumstances conventional pharmacologic or ultrafiltration goals might best be directed toward central venous pressures rather than left ventricular or cardiac output parameters. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Infusion of noradrenaline through the proximal line of a migrated central venous catheter.

    PubMed

    Freer, M; Noble, S

    2012-08-01

    A 41-year-old, obese, patient was admitted to Accident and Emergency with a history of leg cellulitis. A central line was inserted. Documented aspiration of blood from all lines, central venous pressure trace obtained and correct position noted on the chest X-ray (CXR). The patient became increasingly septic despite antibiotic therapy. He was subsequently commenced on a noradrenaline infusion; however, the blood pressure was unresponsive. On admission to the intensive care unit (ICU), it was noted he had an area of white skin over the right clavicle. The infusions were stopped and a CXR confirmed proximal migration of the line. The central line was re-sited and his noradrenaline recommenced with an improvement in his blood pressure. Acute renal failure developed which required haemofiltration for 24 hours. The condition improved and the patient was discharged from ICU. It took several weeks for his renal function to return to normal, but he was discharged home with no permanent damage.

  4. An estimation of intracranial blood flow in the new-born infant.

    PubMed Central

    Cross, K W; Dear, P R; Hathorn, M K; Hyams, A; Kerslake, D M; Milligan, D W; Rahilly, P M; Stothers, J K

    1979-01-01

    1. A non-invasive method for the estimation of the intracranial blood flow of the new-born infant is described, and results obtained with it are presented. 2. The technique is a novel application of the principle of blood flow measurement by venous occlusion plethysmography. It is possible to apply a plethysmographic technique to the neonatal cranium because the presence of open sutures between the component bones permits small, but readily measurable, changes in intracranial volume to occur. 3. Skull volume changes are calculated from changes in the occipito-frontal circumference of the cranium as recorded and measured with a mercury-in-Silastic strain gauge. 4. The jugular veins in the baby's neck are occluded by finger pressure and there follows an increase in skull volume, which is rapid at first, but which decreases exponentially as venous drainage diverts to non-occluded channels such as the vertebral venous plexus. At the instant of jugular occlusion the rate of skull volume increase is representative of the rate of flow in the jugular vessels prior to occlusion, and so provides an index of the relative magnitude of the intracranial blood flow. The method thus allows changes in intracranial blood flow to be followed. When occlusion is released cranial volume decreases, initially rapidly, but slowing exponentially as resting volume is regained. 5. A theoretical model of the events occurring during the inflow and outflow phases has been developed, and a formula derived which allows an estimation to be made of the flow of blood through uncompressed channels. The measured value of jugular blood flow can then be augmented to an estimate of total intracranial flow. 6. The mean cerebral blood flow of sixteen normal babies was estimated to be 40 ml. 100 g-1.min-1 (S.D. = +/- 11.63). Images Fig. 2 Fig. 6 PMID:458665

  5. Use of Capillary Blood Samples Leads to Higher Parasitemia Estimates and Higher Diagnostic Sensitivity of Microscopic and Molecular Diagnostics of Malaria than Venous Blood Samples.

    PubMed

    Mischlinger, Johannes; Pitzinger, Paul; Veletzky, Luzia; Groger, Mirjam; Zoleko-Manego, Rella; Adegnika, Ayola A; Agnandji, Selidji T; Lell, Bertrand; Kremsner, Peter G; Tannich, Egbert; Mombo-Ngoma, Ghyslain; Mordmüller, Benjamin; Ramharter, Michael

    2018-05-25

    Diagnosis of malaria is usually based on samples of peripheral blood. However, it is unclear whether capillary (CAP) or venous (VEN) blood samples provide better diagnostic performance. Quantitative differences of parasitemia between CAP and VEN blood and diagnostic performance characteristics were investigated. Patients were recruited between September 2015 and February 2016 in Gabon. Light microscopy and qPCR quantified parasitemia of paired CAP and VEN samples, whose preparation followed the exact same methodology. CAP and VEN performance characteristics using microscopy were evaluated against a qPCR gold-standard. Microscopy revealed a median (IQR) parasites/L of 495 (853,243) in CAP and 429 (524,074) in VEN samples manifesting in a +16.6% (p=0.04) higher CAPparasitemia compared with VENparasitemia. Concordantly, qPCR demonstrated that -0.278 (p=0.006) cycles were required for signal detection in CAP samples. CAPsensitivity of microscopy relative to the gold-standard was 81.5% (77.485.6%) versus VENsensitivity of 73.4% (68.878.1%), while CAPspecificity and VENspecificity were 91%. CAPsensitivity and VENsensitivity dropped to 63.3% and 45.9%, respectively for a sub-population of low-level parasitemias while specificities were 92%. CAP sampling leads to higher parasitemias compared to VEN sampling and improves diagnostic sensitivity. These findings may have important implications for routine diagnostics, research and elimination campaigns of malaria.

  6. Noninvasive methods for haemoglobin screening in prospective blood donors.

    PubMed

    Belardinelli, A; Benni, M; Tazzari, P L; Pagliaro, P

    2013-08-01

    The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening. Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (n = 445 donors) and by the Pronto-7 (Masimo) test (n = 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter). Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0.29 g/dl, the standard deviation of the differences (SDD) of 0.98 and 95% limits of agreement from -1.64 to 2.21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of -0.53 g/dl, SDD of 1.04 and 95% limits of agreement from -2.57 to 1.51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0.83 g/dl, SDD of 0.70 and 95% limits of agreement from -0.54 to 2.20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99.5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively. Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity. © 2013 International Society of Blood Transfusion.

  7. Venous thromboembolism after major venous injuries: Competing priorities.

    PubMed

    Frank, Brian; Maher, Zoё; Hazelton, Joshua P; Resnick, Shelby; Dauer, Elizabeth; Goldenberg, Anna; Lubitz, Andrea L; Smith, Brian P; Saillant, Noelle N; Reilly, Patrick M; Seamon, Mark J

    2017-12-01

    Venous thromboembolism (VTE) after major vascular injury (MVI) is particularly challenging because the competing risk of thrombosis and embolization after direct vessel injury must be balanced with risk of bleeding after surgical repair. We hypothesized that venous injuries, repair type, and intraoperative anticoagulation would influence VTE formation after MVI. A multi-institution, retrospective cohort study of consecutive MVI patients was conducted at three urban, Level I centers (2005-2013). Patients with MVI of the neck, torso, or proximal extremities (to elbows/knees) were included. Our primary study endpoint was the development of VTE (DVT or pulmonary embolism [PE]). The 435 major vascular injury patients were primarily young (27 years) men (89%) with penetrating (84%) injuries. When patients with (n = 108) and without (n = 327) VTE were compared, we observed no difference in age, mechanism, extremity injury, tourniquet use, orthopedic and spine injuries, damage control, local heparinized saline, or vascular surgery consultation (all p > 0.05). VTE patients had greater Injury Severity Score (ISS) (17 vs. 12), shock indices (1 vs. 0.9), and more torso (58% vs. 35%) and venous (73% vs. 48%) injuries, but less often received systemic intraoperative anticoagulation (39% vs. 53%) or postoperative enoxaparin (47% vs. 61%) prophylaxis (all p < 0.05). After controlling for ISS, hemodynamics, injured vessel, intraoperative anticoagulation, and postoperative prophylaxis, multivariable analysis revealed venous injury was independently predictive of VTE (odds ratio, 2.7; p = 0.002). Multivariable analysis of the venous injuries subset (n = 237) then determined that only delay in starting VTE chemoprophylaxis (odds ratio, 1.3/day; p = 0.013) independently predicted VTE after controlling for ISS, hemodynamics, injured vessel, surgical subspecialty, intraoperative anticoagulation, and postoperative prophylaxis. Overall, 3.4% of venous injury patients developed PE, but PE

  8. Involvement of pterygoid venous plexus in patulous eustachian tube symptoms.

    PubMed

    Oshima, Takeshi; Ogura, Masaki; Kikuchi, Toshiaki; Hori, Yoko; Mugikura, Shunji; Higano, Shuichi; Takahashi, Shoki; Kawase, Tetsuaki; Kobayashi, Toshimitsu

    2007-07-01

    The pterygoid venous plexus (PVP) is an important factor in the mechanism of eustachian tube (ET) closure under conditions that can cause increased venous pressure in the head, such as during neck compression and postural change from the sitting/standing to the recumbent position. The symptoms of patulous ET are usually improved by neck compression or postural change (from sitting/standing to recumbent position). Venous congestion around the ET and/or gravitational change may be involved in the changing degree of symptoms, but its mechanism is not understood. This study investigated whether the PVP is involved. The dimensions of soft tissues surrounding ET were measured on magnetic resonance images before and after neck compression. The lateral pterygoid muscle became enlarged after neck compression. Simultaneously, the volume of venous plexus observed between the medial pterygoid muscle and tensor veli palatini muscle was increased. Such enlargement was probably due to blood pooling in the PVP, resulting in protrusion of the ET anterior wall to the luminal side, and decreased ET patency.

  9. [Sequence of venous blood flow alterations in patients after recently endured acute thrombosis of lower-limb deep veins based on the findings of ultrasonographic duplex scanning].

    PubMed

    Tarkovskiĭ, A A; Zudin, A M; Aleksandrova, E S

    2009-01-01

    This study was undertaken to investigate the sequence of alterations in the venous blood flow to have occurred within the time frame of one year after sustained acute thrombosis of the lower-limb deep veins, which was carried out using the standard technique of ultrasonographic duplex scanning. A total of thirty-two 24-to-62-year-old patients presenting with newly onset acute phlebothrombosis were followed up. All the patients were sequentially examined at 2 days, 3 weeks, 3 months, 6 months and 12 months after the manifestation of the initial clinical signs of the disease. Amongst the parameters to determine were the patency of the deep veins and the condition of the valvular apparatus of the deep, superficial and communicant veins. According to the obtained findings, it was as early as at the first stage of the phlebohaemodynamic alterations after the endured thrombosis, i. e., during the acute period of the disease, that seven (21.9%) patients were found to have developed valvular insufficiency of the communicant veins of the cms, manifesting itself in the formation of a horizontal veno-venous reflux, and 6 months later, these events were observed to have occurred in all the patients examined (100%). Afterwards, the second stage of the phlebohaemodynamic alterations was, simultaneously with the process of recanalization of the thrombotic masses in the deep veins, specifically characterized by the formation of valvular insufficiency of the latter, manifesting itself in the form of the development of a deep vertical veno-venous reflux, which was revealed at month six after the onset of the disease in 56.3% of the examined subjects, to be then observed after 12 months in 93.8% of the patients involved. Recanalization of thrombotic masses was noted to commence 3 months after the onset of thrombosis in twelve (37.5%) patients, and after 12 months it was seen to ensue in all the patients (100%), eventually ending in complete restoration of the patency of the affected

  10. Patterning mechanisms of the sub-intestinal venous plexus in zebrafish

    PubMed Central

    Goi, Michela; Childs, Sarah J.

    2017-01-01

    Despite considerable interest in angiogenesis, organ-specific angiogenesis remains less well characterized. The vessels that absorb nutrients from the yolk and later provide blood supply to the developing digestive system are primarily venous in origin. In zebrafish, these are the vessels of the Sub-intestinal venous plexus (SIVP) and they represent a new candidate model to gain an insight into the mechanisms of venous angiogenesis. Unlike other vessel beds in zebrafish, the SIVP is not stereotypically patterned and lacks obvious sources of patterning information. However, by examining the area of vessel coverage, number of compartments, proliferation and migration speed we have identified common developmental steps in SIVP formation. We applied our analysis of SIVP development to obd mutants that have a mutation in the guidance receptor PlexinD1. obd mutants show dysregulation of nearly all parameters of SIVP formation. We show that the SIVP responds to a unique combination of pathways that control both arterial and venous growth in other systems. Blocking Shh, Notch and Pdgf signaling has no effect on SIVP growth. However Vegf promotes sprouting of the predominantly venous plexus and Bmp promotes outgrowth of the structure. We propose that the SIVP is a unique model to understand novel mechanisms utilized in organ-specific angiogenesis. PMID:26477558

  11. Limb venous distension evokes sympathetic activation via stimulation of the limb afferents in humans.

    PubMed

    Cui, Jian; McQuillan, Patrick M; Blaha, Cheryl; Kunselman, Allen R; Sinoway, Lawrence I

    2012-08-15

    We have recently shown that a saline infusion in the veins of an arterially occluded human forearm evokes a systemic response with increases in muscle sympathetic nerve activity (MSNA) and blood pressure. In this report, we examined whether this response was a reflex that was due to venous distension. Blood pressure (Finometer), heart rate, and MSNA (microneurography) were assessed in 14 young healthy subjects. In the saline trial (n = 14), 5% forearm volume normal saline was infused in an arterially occluded arm. To block afferents in the limb, 90 mg of lidocaine were added to the same volume of saline in six subjects during a separate visit. To examine whether interstitial perfusion of normal saline alone induced the responses, the same volume of albumin solution (5% concentration) was infused in 11 subjects in separate studies. Lidocaine abolished the MSNA and blood pressure responses seen with saline infusion. Moreover, compared with the saline infusion, an albumin infusion induced a larger (MSNA: Δ14.3 ± 2.7 vs. Δ8.5 ± 1.3 bursts/min, P < 0.01) and more sustained MSNA and blood pressure responses. These data suggest that venous distension activates afferent nerves and evokes a powerful systemic sympathoexcitatory reflex. We posit that the venous distension plays an important role in evoking the autonomic adjustments seen with postural stress in human subjects.

  12. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    NASA Astrophysics Data System (ADS)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  13. Sympathetic and cardiovascular responses to venous distension in an occluded limb.

    PubMed

    Cui, Jian; Leuenberger, Urs A; Gao, Zhaohui; Sinoway, Lawrence I

    2011-12-01

    We recently showed that a fixed volume (i.e., 40 ml) of saline infused into the venous circulation of an arterially occluded vascular bed increases muscle sympathetic nerve activity (MSNA) and blood pressure. In the present report, we hypothesized that the volume and rate of infusion would influence the magnitude of the sympathetic response. Blood pressure, heart rate, and MSNA were assessed in 13 young healthy subjects during forearm saline infusions (arrested circulation). The effects of different volumes of saline (i.e., 2%, 3%, 4%, or 5% forearm volume at 30 ml/min) and different rates of infusion (i.e., 5% forearm volume at 10, 20, or 30 ml/min) were evaluated. MSNA and blood pressure responses were linked with the infusion volume. Infusion of 5% of forearm volume evoked greater MSNA responses than did infusion of 2% of forearm volume (Δ11.6 ± 1.9 vs. Δ3.1 ± 1.8 bursts/min and Δ332 ± 105 vs. Δ38 ± 32 units/min, all P < 0.05). Moreover, greater MSNA responses were evoked by saline infusion at 30 ml/min than 10 ml/min (P < 0.05). Sonographic measurements confirmed that the saline infusions induced forearm venous distension. The results suggest that volume and rate of saline infusion are important factors in evoking sympathetic activation. We postulate that venous distension contributes to cardiovascular autonomic adjustment in humans.

  14. Risk factors associated with PICC-related upper extremity venous thrombosis in cancer patients.

    PubMed

    Yi, Xiao-lei; Chen, Jie; Li, Jia; Feng, Liang; Wang, Yan; Zhu, Jia-An; Shen, E; Hu, Bing

    2014-03-01

    To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality

  15. The Need of Slanted Side Holes for Venous Cannulae

    PubMed Central

    Park, Joong Yull

    2012-01-01

    Well-designed cannulae must allow good flow rate and minimize nonphysiologic load. Venous cannulae generally have side holes to prevent the rupture of blood vessel during perfusion. Optimizing side hole angle will yield more efficient and safe venous cannulae. A numerical modeling was used to study the effect of the angle (0°–45°) and number (0–12) of side holes on the performance of cannulae. By only slanting the side holes, it increases the flow rate up to 6% (in our models). In addition, it was found that increasing the number of side holes reduces the shear rate up to 12% (in our models). A new parameter called “penetration depth” was introduced to describe the interfering effect of stream jets from side holes, and the result showed that the 45°-slanted side holes caused minimum interfering for the flow in cannula. Our quantitative hemodynamic analysis study provides important guidelines for venous cannulae design. PMID:22291856

  16. Tapping but not massage enhances vasodilation and improves venous palpation of cutaneous veins.

    PubMed

    Ichimura, Mika; Sasaki, Shinsuke; Mori, Masaharu; Ogino, Tetsuya

    2015-01-01

    This paper investigated whether tapping on the median cubital vein or massaging the forearm was more effective in obtaining better venous palpation for venipuncture. Forty healthy volunteers in their twenties were subjected to tapping (10 times in 5 sec) or massage (10 strokes in 20 sec from the wrist to the cubital fossa) under tourniquet inflation on the upper arm. Venous palpation was assessed using the venous palpation score (0-6, with 0 being impalpable). Three venous factors-venous depth, cross-sectional area, and elevation-were also measured using ultrasonography. The venous palpation score increased significantly by tapping but not by massage. Moreover, all 3 venous measurements changed significantly by tapping, while only the depth decreased significantly by massage. The three venous measurements correlated significantly with the venous palpation score, indicating that they are useful objective indicators for evaluating vasodilation. We suggest that tapping is an effective vasodilation technique.

  17. The effects of arterial carbon dioxide partial pressure and sevoflurane on capillary venous cerebral blood flow and oxygen saturation during craniotomy.

    PubMed

    Klein, Klaus Ulrich; Glaser, Martin; Reisch, Robert; Tresch, Achim; Werner, Christian; Engelhard, Kristin

    2009-07-01

    Intraoperative routine monitoring of cerebral blood flow and oxygenation remains a technological challenge. Using the physiological principle of carbon dioxide reactivity of cerebral vasculature, we investigated a recently developed neuromonitoring device (oxygen-to-see, O2C device) for simultaneous measurements of regional cerebral blood flow (rvCBF), blood flow velocity (rvVelo), oxygen saturation (srvO2), and hemoglobin amount (rvHb) at the capillary venous level in patients subjected to craniotomy. Twenty-six neurosurgical patients were randomly assigned to anesthesia with 1.4% or 2.0% sevoflurane end-tidal concentration. After craniotomy, a fiberoptic probe was applied on a macroscopically healthy surface of cerebral tissue next to the site of surgery. Simultaneous measurements in 2 and 8 mm cerebral depth were performed in each patient during lower (35 mm Hg) and higher (45 mm Hg) levels (random order) of arterial carbon dioxide partial pressure (PaCO2). The principle of these measurements relies on the combination of laser-Doppler flowmetry (rvCBF, rvVelo) and photo-spectrometry (srvO2, rvHb). Linear models were fitted to test changes of end points (rvCBF, rvVelo, srvO2, rvHb) in response to lower and higher levels of PaCO2, 1.4% and 2.0% sevoflurane end-tidal concentration, and 2 and 8 mm cerebral depth. RvCBF and rvVelo were elevated by PaCO2 independent of sevoflurane concentration in 2 and 8 mm depth of cerebral tissue (P < 0.001). Higher PaCO2 induced an increase in mean srvO2 from 50% to 68% (P < 0.001). RvVelo (P < 0.001) and srvO2 (P = 0.007) were higher in 8 compared with 2 mm cerebral depth. RvHb was not influenced by alterations in PaCO2 but positively correlated to sevoflurane concentration (P = 0.005). Increases in rvCBF and rvVelo by PaCO2 suggest preserved hypercapnic vasodilation under anesthesia with sevoflurane 1.4% and 2.0% end-tidal concentration. A consecutive increase in srvO2 implies that cerebral arteriovenous difference in oxygen was

  18. Elevated plasma factor VIII enhances venous thrombus formation in rabbits: contribution of factor XI, von Willebrand factor and tissue factor.

    PubMed

    Sugita, Chihiro; Yamashita, Atsushi; Matsuura, Yunosuke; Iwakiri, Takashi; Okuyama, Nozomi; Matsuda, Shuntaro; Matsumoto, Tomoko; Inoue, Osamu; Harada, Aya; Kitazawa, Takehisa; Hattori, Kunihiro; Shima, Midori; Asada, Yujiro

    2013-07-01

    Elevated plasma levels of factor VIII (FVIII) are associated with increased risk of deep venous thrombosis. The aim of this study is to elucidate how elevated FVIII levels affect venous thrombus formation and propagation in vivo. We examined rabbit plasma FVIII activity, plasma thrombin generation, whole blood coagulation, platelet aggregation and venous wall thrombogenicity before and one hour after an intravenous infusion of recombinant human FVIII (rFVIII). Venous thrombus induced by the endothelial denudation of rabbit jugular veins was histologically assessed. Thrombus propagation was evaluated as indocyanine green fluorescence intensity. Argatroban, a thrombin inhibitor, and neutralised antibodies for tissue factor (TF), factor XI (FXI), and von Willebrand factor (VWF) were infused before or after thrombus induction to investigate their effects on venous thrombus formation or propagation. Recombinant FVIII (100 IU/kg) increased rabbit plasma FVIII activity two-fold and significantly enhanced whole blood coagulation and total plasma thrombin generation, but did not affect initial thrombin generation time, platelet aggregation and venous wall thrombogenicity. The rFVIII infusion also increased the size of venous thrombus 1 hour after thrombus induction. Argatroban and the antibodies for TF, FXI or VWF inhibited such enhanced thrombus formation and all except TF suppressed thrombus propagation. In conclusion, elevated plasma FVIII levels enhance venous thrombus formation and propagation. Excess thrombin generation by FXI and VWF-mediated FVIII recruitment appear to contribute to the growth of FVIII-driven venous thrombus.

  19. Performance of a new test strip for freestyle blood glucose monitoring systems.

    PubMed

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations <75 mg/dL, 73%, 100%, and 100% of the individual capillary blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  20. Arterial and venous plasma levels of bupivacaine following epidural and intercostal nerve blocks.

    PubMed

    Moore, D C; Mather, L E; Bridenbaugh, P O; Bridenbaugh, L D; Balfour, R I; Lysons, D F; Horton, W G

    1976-07-01

    Arterial and peripheral venous plasma levels of bupivacaine were determined in 30 patients following epidural anesthesia using 150 and 225 mg, as well as following intercostal nerve block with 400 mg. Arterial levels were consistently higher than levels in simultaneously sampled venous blood, and the highest levels occurred with bilateral intercostal nerve block. No evidence of systemic toxicity was observed. The results suggest that bupivacaine may have a wider margin of safety in man than is now stated.

  1. Potential involvement of the extracranial venous system in central nervous system disorders and aging

    PubMed Central

    2013-01-01

    Background The role of the extracranial venous system in the pathology of central nervous system (CNS) disorders and aging is largely unknown. It is acknowledged that the development of the venous system is subject to many variations and that these variations do not necessarily represent pathological findings. The idea has been changing with regards to the extracranial venous system. Discussion A range of extracranial venous abnormalities have recently been reported, which could be classified as structural/morphological, hemodynamic/functional and those determined only by the composite criteria and use of multimodal imaging. The presence of these abnormalities usually disrupts normal blood flow and is associated with the development of prominent collateral circulation. The etiology of these abnormalities may be related to embryologic developmental arrest, aging or other comorbidities. Several CNS disorders have been linked to the presence and severity of jugular venous reflux. Another composite criteria-based vascular condition named chronic cerebrospinal venous insufficiency (CCSVI) was recently introduced. CCSVI is characterized by abnormalities of the main extracranial cerebrospinal venous outflow routes that may interfere with normal venous outflow. Summary Additional research is needed to better define the role of the extracranial venous system in relation to CNS disorders and aging. The use of endovascular treatment for the correction of these extracranial venous abnormalities should be discouraged, until potential benefit is demonstrated in properly-designed, blinded, randomized and controlled clinical trials. Please see related editorial: http://www.biomedcentral.com/1741-7015/11/259. PMID:24344742

  2. In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.

    PubMed

    Pekkan, Kerem; Aka, Ibrahim Basar; Tutsak, Ece; Ermek, Erhan; Balim, Haldun; Lazoglu, Ismail; Turkoz, Riza

    2018-03-11

    Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  3. Hyperspectral venous image quality assessment for optimum illumination range selection based on skin tone characteristics

    PubMed Central

    2014-01-01

    Background Subcutaneous veins localization is usually performed manually by medical staff to find suitable vein to insert catheter for medication delivery or blood sample function. The rule of thumb is to find large and straight enough vein for the medication to flow inside of the selected blood vessel without any obstruction. The problem of peripheral difficult venous access arises when patient’s veins are not visible due to any reason like dark skin tone, presence of hair, high body fat or dehydrated condition, etc. Methods To enhance the visibility of veins, near infrared imaging systems is used to assist medical staff in veins localization process. Optimum illumination is crucial to obtain a better image contrast and quality, taking into consideration the limited power and space on portable imaging systems. In this work a hyperspectral image quality assessment is done to get the optimum range of illumination for venous imaging system. A database of hyperspectral images from 80 subjects has been created and subjects were divided in to four different classes on the basis of their skin tone. In this paper the results of hyper spectral image analyses are presented in function of the skin tone of patients. For each patient, four mean images were constructed by taking mean with a spectral span of 50 nm within near infrared range, i.e. 750–950 nm. Statistical quality measures were used to analyse these images. Conclusion It is concluded that the wavelength range of 800 to 850 nm serve as the optimum illumination range to get best near infrared venous image quality for each type of skin tone. PMID:25087016

  4. Venous Access Devices: Clinical Rounds

    PubMed Central

    Matey, Laurl; Camp-Sorrell, Dawn

    2016-01-01

    Nursing management of venous access devices (VADs) requires knowledge of current evidence, as well as knowledge of when evidence is limited. Do you know which practices we do based on evidence and those that we do based on institutional history or preference? This article will present complex VAD infection and occlusion complications and some of the controversies associated with them. Important strategies for identifying these complications, troubleshooting, and evaluating the evidence related to lack of blood return, malposition, infection, access and maintenance protocols, and scope of practice issues are presented. PMID:28083553

  5. The effect of a cryotherapy gel wrap on the microcirculation of skin affected by chronic venous disorders.

    PubMed

    Kelechi, Teresa J; Mueller, Martina; Zapka, Jane G; King, Dana E

    2011-11-01

    The aim of this randomized clinical trial was to investigate a cryotherapy (cooling) gel wrap applied to lower leg skin affected by chronic venous disorders to determine whether therapeutic cooling improves skin microcirculation. Chronic venous disorders are under-recognized vascular health problems that result in severe skin damage and ulcerations of the lower legs. Impaired skin microcirculation contributes to venous leg ulcer development, thus new prevention therapies should address the microcirculation to prevent venous leg ulcers. Sixty participants (n = 30 per group) were randomized to receive one of two daily 30-minute interventions for four weeks. The treatment group applied the cryotherapy gel wrap around the affected lower leg skin, or compression and elevated the legs on a special pillow each evening at bedtime. The standard care group wore compression and elevated the legs only. Laboratory pre- and post-measures included microcirculation measures of skin temperature with a thermistor, blood flow with a laser Doppler flowmeter, and venous refill time with a photoplethysmograph. Data were collected between 2008 2009 and analysed using descriptive statistics, paired t-tests or Wilcoxon signed ranks tests, logistic regression analyses, and mixed model analyses. Fifty-seven participants (treatment = 28; standard care = 29) completed the study. The mean age was 62 years, 70% female, 50% African American. In the final adjusted model, there was a statistically significant decrease in blood flow between the two groups (-6.2[-11.8; -0.6], P = 0.03). No statistically significant differences were noted in temperature or venous refill time. Study findings suggest that cryotherapy improves blood flow by slowing movement within the microcirculation and thus might potentially provide a therapeutic benefit to prevent leg ulcers. © 2011 Blackwell Publishing Ltd.

  6. What Is High Blood Pressure?

    MedlinePlus

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  7. Managing High Blood Pressure Medications

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Managing High Blood Pressure Medications Updated:Jan 10,2018 When your doctor ... checkup. This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  8. The effect of a cryotherapy gel wrap on the microcirculation of skin affected by Chronic Venous Disorders

    PubMed Central

    Mueller, Martina; Zapka, Jane G.; King, Dana E.

    2011-01-01

    Aim This randomized clinical trial was conducted 2008 – 2009 to investigate a cryotherapy (cooling) gel wrap applied to lower leg skin affected by chronic venous disorders to determine whether therapeutic cooling improves skin microcirculation. Impaired skin microcirculation contributes to venous leg ulcer development, thus new prevention therapies should address the microcirculation to prevent venous leg ulcers. Data Sources Sixty participants (n = 30 per group) were randomized to receive one of two daily 30-minute interventions for four weeks. The treatment group applied the cryotherapy gel wrap around the affected lower leg skin, or compression and elevated the legs on a special pillow each evening at bedtime. The standard care group wore compression and elevated the legs only. Laboratory pre- and post-measures included microcirculation measures of skin temperature with a thermistor, blood flow with a laser Doppler flowmeter, and venous refill time with a photoplethysmograph. Review methods Data were analysed using descriptive statistics, paired t-tests or Wilcoxon signed ranks tests, logistic regression analyses, and mixed model analyses. Results Fifty-seven participants (treatment = 28; standard care = 29) completed the study. The mean age was 62 years, 70% female, 50% African American. In the final adjusted model, there was a statistically significant decrease in blood flow between the two groups (−6.2[−11.8; −0.6], P = 0.03). No statistically significant differences were noted in temperature or venous refill time. Conclusion Study findings suggest that cryotherapy improves blood flow by slowing movement within the microcirculation and thus might potentially provide a therapeutic benefit to prevent leg ulcers. PMID:21592186

  9. A reflectance model for non-contact mapping of venous oxygen saturation using a CCD camera

    NASA Astrophysics Data System (ADS)

    Li, Jun; Dunmire, Barbrina; Beach, Kirk W.; Leotta, Daniel F.

    2013-11-01

    A method of non-contact mapping of venous oxygen saturation (SvO2) is presented. A CCD camera is used to image skin tissue illuminated alternately by a red (660 nm) and an infrared (800 nm) LED light source. Low cuff pressures of 30-40 mmHg are applied to induce a venous blood volume change with negligible change in the arterial blood volume. A hybrid model combining the Beer-Lambert law and the light diffusion model is developed and used to convert the change in the light intensity to the change in skin tissue absorption coefficient. A simulation study incorporating the full light diffusion model is used to verify the hybrid model and to correct a calculation bias. SvO2 in the fingers, palm, and forearm for five volunteers are presented and compared with results in the published literature. Two-dimensional maps of venous oxygen saturation are given for the three anatomical regions.

  10. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    PubMed

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  11. Elevated central venous pressure: a consequence of exercise training-induced hypervolemia?

    NASA Technical Reports Server (NTRS)

    Convertino, V. A.; Mack, G. W.; Nadel, E. R.

    1991-01-01

    Resting blood volumes and arterial and central venous pressures (CVP) were measured in 14 men before and after exercise training to determine whether training-induced hypervolemia is accompanied by a change in total vascular capacitance. In addition, resting levels of plasma arginine vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (Ald), and norepinephrine (NE) were measured. The same measurements were conducted in seven subjects who did not undergo exercise and acted as controls. Exercise training consisted of 10 wk of controlled cycle exercise for 30 min/day, 4 days/wk at 75-80% of maximal O2 uptake (VO2max). A training effect was verified by a 20% increase in VO2max, a resting bradycardia, and a 9% increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased by 16% (P less than 0.05). The percent change in blood volume from before to after training was linearly related to the percent change in CVP (r = 0.903, P less than 0.05). As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was unchanged after exercise training. Plasma AVP, ANP, Ald, and NE were unaltered. Our results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance.

  12. Significance of Maternal and Cord Blood Nucleated Red Blood Cell Count in Pregnancies Complicated by Preeclampsia

    PubMed Central

    Misha, Mehak; Rai, Lavanya

    2014-01-01

    Objectives. To evaluate the effect of preeclampsia on the cord blood and maternal NRBC count and to correlate NRBC count and neonatal outcome in preeclampsia and control groups. Study Design. This is a prospective case control observational study. Patients and Methods. Maternal and cord blood NRBC counts were studied in 50 preeclamptic women and 50 healthy pregnant women. Using automated cell counter total leucocyte count was obtained and peripheral smear was prepared to obtain NRBC count. Corrected WBC count and NRBC count/100 leucocytes in maternal venous blood and in cord blood were compared between the 2 groups. Results. No significant differences were found in corrected WBC count in maternal and cord blood in cases and controls. Significant differences were found in mean cord blood NRBC count in preeclampsia and control groups (40.0 ± 85.1 and 5.9 ± 6.3, P = 0.006). The mean maternal NRBC count in two groups was 2.4 ± 9.0 and 0.8 ± 1.5, respectively (P = 0.214). Cord blood NRBC count cut off value ≤13 could rule out adverse neonatal outcome with a sensitivity of 63% and specificity of 89%. Conclusion. Cord blood NRBC are significantly raised in preeclampsia. Neonates with elevated cord blood NRBC counts are more likely to have IUGR, low birth weight, neonatal ICU admission, respiratory distress syndrome, and assisted ventilation. Below the count of 13/100 leucocytes, adverse neonatal outcome is quite less likely. PMID:24734183

  13. Influence of protein ingestion on human splanchnic and whole-body oxygen consumption, blood flow, and blood temperature.

    PubMed

    Brundin, T; Wahren, J

    1994-05-01

    Splanchnic and whole-body oxygen uptake, blood flow, and blood temperature were studied in 10 healthy subjects before and during 2 hours after oral ingestion of 900 kJ of fish protein. Indirect calorimetry and catheter techniques were used, including blood thermometry in arterial, pulmonary arterial, and hepatic venous blood. After the meal, pulmonary oxygen uptake increased from a basal value of 272 +/- 11 to 332 +/- 23 mL/min. During the first postprandial hour, splanchnic oxygen uptake increased from 62 +/- 5 to 93 +/- 9 mL/min (+50%, P < .05), thereby accounting for 62% +/- 17% of the simultaneous increase in whole-body oxygen consumption. During the second postprandial hour, splanchnic oxygen uptake increased no further, whereas in the extrasplanchnic tissues the oxygen consumption increased, now accounting for the entire simultaneous increase in pulmonary oxygen uptake. Cardiac output increased from basal 6.4 +/- 0.4 to 7.5 +/- 0.5 L/min. Splanchnic blood flow changed little while the arteriohepatic venous oxygen difference increased from 46 +/- 3 to 54 +/- 4 mL/L. Arterial and hepatic venous blood temperatures increased by almost 0.3 degrees C, reflecting a considerable accumulation of heat, indicating a conversion into a positive thermal balance. It is concluded that after protein ingestion, (1) oxygen uptake increases mainly in the splanchnic organs during the first hour, and thereafter exclusively in the extrasplanchnic tissues; (2) the blood flow increases mainly in extrasplanchnic tissues; and (3) the blood temperature increases almost linearly, indicating an upward adjustment of the temperature setpoint in the central thermosensors.

  14. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results

    PubMed Central

    Tonyushkina, Ksenia; Nichols, James H.

    2009-01-01

    Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy

  15. Electrical stimulation of acupoint combinations against deep venous thrombosis in elderly bedridden patients after major surgery.

    PubMed

    Hou, Lili; Chen, Cuiping; Xu, Lei; Yin, Peihao; Peng, Wen

    2013-04-01

    To compare the effects of electrical stimulation of different acupoint combinations among postoperative bedridden elderly patients on hemorheology and deep venous blood flow velocity and investigate the.role of electrical stimulation against deep vein thrombosis (DVT). From November 2010 to October 2011, a total of 160 elderly bedridden patients after major surgery were divided into the conventional care group, invigorating and promoting Qi group, blood-activating and damp-eliminating group, and acupoint-combination stimulation group. Whole blood viscosity, plasma viscosity, D-dimer levels, lower limb skin temperature, lower limb circumference, and flow velocities of the external iliac vein, femoral vein, popliteal vein, and deep calf veins in all patients were documented and compared among the four groups. Whole blood viscosity, plasma viscosity, D-dimer levels, and lower limb circumference were significantly reduced in the blood-activating and damp-eliminating group compared with the conventional care group (P < 0.05) and were almost equal to those in the acupoint-combination stimulation group (P > 0.05). Lower limb venous flow velocities were accelerated in the invigorating and promoting Qi group compared with the other groups, excluding the acupoint-combination stimulation group (P < 0.05). Hemorheological indices in postoperative bedridden elderly patients were improved after combined electrical stimulation at Yinlingquan (SP 9) and Sanyinjiao (SP 6). Combined electrical stimulation at Zusanli (ST 36) and Taichong (LR 3), on the other hand, accelerated lower limb venous flow.

  16. Peripheral i.v. analysis (PIVA) of venous waveforms for volume assessment in patients undergoing haemodialysis.

    PubMed

    Hocking, K M; Alvis, B D; Baudenbacher, F; Boyer, R; Brophy, C M; Beer, I; Eagle, S

    2017-12-01

    The assessment of intravascular volume status remains a challenge for clinicians. Peripheral i.v. analysis (PIVA) is a method for analysing the peripheral venous waveform that has been used to monitor volume status. We present a proof-of-concept study for evaluating the efficacy of PIVA in detecting changes in fluid volume. We enrolled 37 hospitalized patients undergoing haemodialysis (HD) as a controlled model for intravascular volume loss. Respiratory rate (F0) and pulse rate (F1) frequencies were measured. PIVA signal was obtained by fast Fourier analysis of the venous waveform followed by weighing the magnitude of the amplitude of the pulse rate frequency. PIVA was compared with peripheral venous pressure and standard monitoring of vital signs. Regression analysis showed a linear correlation between volume loss and change in the PIVA signal (R2=0.77). Receiver operator curves demonstrated that the PIVA signal showed an area under the curve of 0.89 for detection of 20 ml kg-1 change in volume. There was no correlation between volume loss and peripheral venous pressure, blood pressure or pulse rate. PIVA-derived pulse rate and respiratory rate were consistent with similar numbers derived from the bio-impedance and electrical signals from the electrocardiogram. PIVA is a minimally invasive, novel modality for detecting changes in fluid volume status, respiratory rate and pulse rate in spontaneously breathing patients with peripheral i.v. cannulas. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  17. Mean hemoglobin levels in venous blood samples and prevalence of anemia in Japanese elementary and junior high school students.

    PubMed

    Igarashi, Toru; Itoh, Yasuhiko; Maeda, Miho; Igarashi, Tsutomu; Fukunaga, Yoshitaka

    2012-01-01

    Screening for anemia has been performed in schools in Japan for over 30 years. The long-term effect of the nuclear power plant disaster on the prevalence of anemia in school age children is unknown. This research was performed to evaluate the prevalence of anemia in school age children and to determine grade-level and gender-related reference hemoglobin (Hb) levels prior to the nuclear disaster. Data for this research were obtained from results of screening for anemia obtained by venous blood sampling in schools in 2002. Mean Hb levels were calculated for each grade level (elementary school grades 1-6 and junior high school years 1-3) and according to gender, and the prevalence of anemia was determined. In our research, Tokyo Health Service Association guidelines were used to determine reference Hb levels for anemia. We demonstrated that Hb levels in boys increased with age during childhood and adolescence (from 13.1 ± 0.7 g/dL in 7 year olds to 14.9 ± 1.1 g/dL in 15 year olds); in girls, Hb levels peaked at menarche (13.7 ± 0.8 g/dL in 12 year olds), decreasing slightly thereafter (13.4 ± 1.1 g/dL in 15 year olds). The prevalence of anemia was 0.26% in elementary school boys, 0.27% in elementary school girls, and 1.21% in junior high school boys. The prevalence of anemia in second- and third-year junior high school girls was lower than that in first-year junior high school girls. Among all junior high school girls, 5.73% had mild anemia. Iron-deficiency anemia is the commonest type of anemia in high school girls, secondary to the relative lack of iron due to menstruation, the growth spurt and exercise. Appropriate dietary therapy and treatment of anemia, together with education about the dietary prevention of anemia, are important to reduce the prevalence of anemia in high school students. When complete blood counts are performed in regions thought to be affected by the Fukushima nuclear power plant disaster, our report can serve as a reference during

  18. Prevention of catheter-related blood stream infection.

    PubMed

    Byrnes, Matthew C; Coopersmith, Craig M

    2007-08-01

    Catheter-related blood stream infections are a morbid complication of central venous catheters. This review will highlight a comprehensive approach demonstrated to prevent catheter-related blood stream infections. Elements of prevention important to inserting a central venous catheter include proper hand hygiene, use of full barrier precautions, appropriate skin preparation with 2% chlorhexidine, and using the subclavian vein as the preferred anatomic site. Rigorous attention needs to be given to dressing care, and there should be daily assessment of the need for central venous catheters, with prompt removal as soon as is practicable. Healthcare workers should be educated routinely on methods to prevent catheter-related blood stream infections. If rates remain higher than benchmark levels despite proper bedside practice, antiseptic or antibiotic-impregnated catheters can also prevent infections effectively. A recent program utilizing these practices in 103 ICUs in Michigan resulted in a 66% decrease in infection rates. There is increasing recognition that a comprehensive strategy to prevent catheter-related blood stream infections can prevent most infections, if not all. This suggests that thousands of infections can potentially be averted if the simple practices outlined herein are followed.

  19. Venous Ulcers

    PubMed Central

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  20. Apixaban or Dalteparin in Reducing Blood Clots in Patients With Cancer Related Venous Thromboembolism

    ClinicalTrials.gov

    2017-12-28

    Cerebral Vein Thrombosis; Deep Vein Thrombosis; Gonadal Thrombosis; Hepatic Thrombosis; Malignant Neoplasm; Mesenteric Thrombosis; Metastatic Malignant Neoplasm; Portal Vein Thrombosis; Pulmonary Embolism; Renal Vein Thrombosis; Splenic Thrombosis; Venous Thromboembolism

  1. Correlation mapping method of OCT for visualization blood vessels in brain

    NASA Astrophysics Data System (ADS)

    Izotova, O. A.; Kalyanov, A. L.; Lychagov, V. V.; Semyachkina-Glushkovskaya, O. V.

    2013-11-01

    The burning issue in modern medicine is the diagnosis and treatment of various life-threatening diseases, in particular the diseases of brain. One of them is intracranial hemorrhage (ICH). It occurs especially among newborn babies and is hard-diagnosed. In order to understand the nature of the ICH, the microcirculation of blood, which serves key functions within the body, is analyzed. On this basis a series of experiments was done, in the results of which it was showed, that latent stage of ICH is characterized by decrease of venous blood outflow and the loss of sensitivity of sagittal vein to vasoconstrictor effect of adrenaline. So, stress-related changes of the cerebral venous blood flow (CVBF) can be the source of this disease. In this paper registration CVBF was made with the help of commercially available Thorlabs Swept Source OCT System, using the correlation mapping method. In this method values of correlation coefficient of several images are analyzed. In the result of the algorithm the correlation map was obtained. By the resulting map the diameter of vessels was calculated, which is necessary for examination of effects of adrenalin to the vessels and identification symptoms of ICH.

  2. Pentoxifylline for treating venous leg ulcers.

    PubMed

    Jull, A; Arroll, B; Parag, V; Waters, J

    2007-07-18

    Healing of venous leg ulcers is improved by the use of compression bandaging but some venous ulcers remain unhealed, and some people are unsuitable for compression therapy. Pentoxifylline, a drug which helps blood flow, has been used to treat venous leg ulcers. An earlier version of this review included 9 randomised controlled trials, but more research has been since been conducted and an updated review is required. To assess the effects of pentoxifylline (oxpentifylline or Trental 400) for treating venous leg ulcers, compared with placebo, or other therapies, in the presence or absence of compression therapy. For this second update we searched the Cochrane Wounds Group Specialised Register, CENTRAL, MEDLINE, EMBASE and Cinahl (date of last search was February 2007), and reference lists of relevant articles. Randomised trials comparing pentoxifylline with placebo or other therapy in the presence or absence of compression, in people with venous leg ulcers. Details from eligible trials were extracted and summarised by one author using a coding sheet. Data extraction was independently verified by one other author. Twelve trials involving 864 participants were included. The quality of trials was variable. Eleven trials compared pentoxifylline with placebo or no treatment; in seven of these trials patients received compression therapy. In one trial pentoxifylline was compared with defibrotide in patients who also received compression. Combining 11 trials that compared pentoxifylline with placebo or no treatment (with or without compression) demonstrated that pentoxifylline is more effective than placebo in terms of complete ulcer healing or significant improvement (RR 1.70, 95% CI 1.30 to 2.24). Significant heterogeneity was associated with differences in sample populations (hard-to-heal samples compared with "normal" healing samples). Pentoxifylline plus compression is more effective than placebo plus compression (RR 1.56, 95% CI 1.14 to 2.13). Pentoxifylline in the

  3. Significance of pathological positive superior mesenteric/portal venous invasion in pancreatic cancer.

    PubMed

    Tewari, Mallika

    2016-12-01

    Pancreaticoduodenectomy with superior mesenteric/portal venous resection for pancreatic ductal adenocarcinoma (PDAC) is frequently performed with no added morbidity or mortality in case of tumor abutment to the superior mesenteric or portal vein so as to obtain a margin negative resection. True histopathological portal vein invasion is found only in a small subset of such patients. The aim of this review aimed to discuss the significance of histopathological venous invasion in PDAC. For this review available data was searched from PubMed and analyzed. No randomized trials have been published on this topic. Existing data on prognostic factors in histopathological venous invasion by PDAC are limited and recent studies indicate worse survival in this subgroup of patients. In addition, venous invasion in PDAC has been associated with large tumors, involved lymph nodes, perineural invasion and R1 resection. The survival of patients with portal venous resection but without histologic venous invasion is reportedly better than those with histopathological venous invasion; though conflicting studies do exist on the subject. Some studies also relate the depth of venous invasion to prognosis after surgical resection of PDAC. Frank/'histopathological' invasion of superior mesenteric/portal venous and R1 resection indicate a very poor survival. Such patients may be given the opportunity of benefit of neoadjuvant treatment.

  4. Mixed venous oxygen saturation monitoring revisited: thoughts for critical care nursing practice.

    PubMed

    Christensen, Martin

    2012-05-01

    continuously measure cardiac output, SvO(2) monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO(2) or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO(2), trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO(2) will be approximately 16% lower. Copyright © 2011 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  5. Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar, Miroslav; Ceral, Jiri, E-mail: ceral.jiri@fnhk.c; Krajina, Antonin

    Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutivemore » patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.« less

  6. An Isolated Venous Sac as a Novel Site for Cell Therapy in Diabetes Mellitus

    PubMed Central

    Kakabadze, Zurab; Shanava, Koba; Ricordi, Camillo; Shapiro, A.M. James; Gupta, Sanjeev; Berishvili, Ekaterine

    2013-01-01

    Background Transplanting pancreatic islets is of significant interest for type 1 diabetes mellitus. After intraportal injection of islets, inferior engraftment and eventual loss of transplanted islets constitute major limitations. Therefore, alternative approaches will be helpful. Here, we evaluated in animals whether an isolated venous sac would support survival of transplanted islets, along with correction of hyperglycemia. Methods Pancreatic islets isolated from adult Lewis rats were transplanted either into an isolated venous sac made from lumbar vein or into the portal vein of syngeneic rats. The integrity and vascular organization of the venous sac was determined by studies of the local microcirculation. The engraftment, survival, and function of transplanted islets were analyzed by histology, including endocrine function in situ and by glycemic control in rats with streptozotocin-induced diabetes. Results Transplanted islets showed normal morphology with insulin expression in isolated venous sac during the long term. Transplanted islets received blood supply from vasa vasorum and had access to drainage through venous tributaries in the venous sac. This resulted in restoration of euglycemia in diabetic rats. Removal of islet graft-bearing venous sac in diabetic rats led to recurrence of hyperglycemia. By contrast, euglycemia was not restored in rats treated by intraportal transplantation of islets. Conclusions We demonstrated that pancreatic islets successfully engrafted and functioned in the isolated venous sac with ability to restore euglycemia in diabetic rats. Therefore, the isolated venous sac offers a new site for transplantation of pancreatic islets. This would be clinically beneficial as an alternative to intrahepatic islet transplantation. PMID:22814331

  7. Temperature and blood flow distribution in the human leg during passive heat stress

    PubMed Central

    Chiesa, Scott T.; Trangmar, Steven J.

    2016-01-01

    The influence of temperature on the hemodynamic adjustments to direct passive heat stress within the leg's major arterial and venous vessels and compartments remains unclear. Fifteen healthy young males were tested during exposure to either passive whole body heat stress to levels approaching thermal tolerance [core temperature (Tc) + 2°C; study 1; n = 8] or single leg heat stress (Tc + 0°C; study 2; n = 7). Whole body heat stress increased perfusion and decreased oscillatory shear index in relation to the rise in leg temperature (Tleg) in all three major arteries supplying the leg, plateauing in the common and superficial femoral arteries before reaching severe heat stress levels. Isolated leg heat stress increased arterial blood flows and shear patterns to a level similar to that obtained during moderate core hyperthermia (Tc + 1°C). Despite modest increases in great saphenous venous (GSV) blood flow (0.2 l/min), the deep venous system accounted for the majority of returning flow (common femoral vein 0.7 l/min) during intense to severe levels of heat stress. Rapid cooling of a single leg during severe whole body heat stress resulted in an equivalent blood flow reduction in the major artery supplying the thigh deep tissues only, suggesting central temperature-sensitive mechanisms contribute to skin blood flow alone. These findings further our knowledge of leg hemodynamic responses during direct heat stress and provide evidence of potentially beneficial vascular alterations during isolated limb heat stress that are equivalent to those experienced during exposure to moderate levels of whole body hyperthermia. PMID:26823344

  8. [On Individualization of Therapeutic Doses of Optical Radiation according to Changes in Parameters of Blood Oxygenation].

    PubMed

    Zalesskaya, G A

    2015-01-01

    The effect of in vivo laser irradiation by optical radiation on blood from different patients is studied. The objects of research were three series of blood samples from patients whose treatment course included extracorporeal UV blood irradiation, intravenous laser blood irradiation and supra-venous blood laser irradiation. Before and after irradiation the results on optic oximetry and gas content of venous blood were compared. The results of positive and negative influence of blood irradiation on characteristics of an oxygen exchange in separate patients and on the maintenance of some products of metabolism are represented. It is shown that at the same power dose, their changes depend on individual, initial values of hemoglobin oxygen saturation of venous blood and its photoinduced changes which objectively reflect individual sensitivity of patients to the action of optical radiation on blood and can be used for assessment of the efficiency of phototherapy.

  9. Elevated central venous pressure: A consequence of exercise training-induced hypervolemia

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.; Mack, Gary W.; Nadel, Ethan R.

    1990-01-01

    Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.

  10. The Ovine Cerebral Venous System: Comparative Anatomy, Visualization, and Implications for Translational Research

    PubMed Central

    Nitzsche, Björn; Lobsien, Donald; Seeger, Johannes; Schneider, Holm; Boltze, Johannes

    2014-01-01

    Cerebrovascular diseases are significant causes of death and disability in humans. Improvements in diagnostic and therapeutic approaches strongly rely on adequate gyrencephalic, large animal models being demanded for translational research. Ovine stroke models may represent a promising approach but are currently limited by insufficient knowledge regarding the venous system of the cerebral angioarchitecture. The present study was intended to provide a comprehensive anatomical analysis of the intracranial venous system in sheep as a reliable basis for the interpretation of experimental results in such ovine models. We used corrosion casts as well as contrast-enhanced magnetic resonance venography to scrutinize blood drainage from the brain. This combined approach yielded detailed and, to some extent, novel findings. In particular, we provide evidence for chordae Willisii and lateral venous lacunae, and report on connections between the dorsal and ventral sinuses in this species. For the first time, we also describe venous confluences in the deep cerebral venous system and an ‘anterior condylar confluent’ as seen in humans. This report provides a detailed reference for the interpretation of venous diagnostic imaging findings in sheep, including an assessment of structure detectability by in vivo (imaging) versus ex vivo (corrosion cast) visualization methods. Moreover, it features a comprehensive interspecies-comparison of the venous cerebral angioarchitecture in man, rodents, canines and sheep as a relevant large animal model species, and describes possible implications for translational cerebrovascular research. PMID:24736654

  11. Prevention of venous pain and phlebitis caused by epirubicin hydrochloride.

    PubMed

    Sugimoto, Masakazu; Matsui, Masateru; Harada, Masanori; Yamauchi, Yumiko; Moriyama, Nao; Andou, Kanae; Yamamoto, Makoto; Yamaoka, Hisayo; Ono, Chiemi; Ishikawa, Mami; Kamo, Nobuyuki; Ikeda, Tadashi; Yamaoka, Keiko

    2009-06-01

    Many patients complain of venous pain or develop phlebitis following treatment with epirubicin hydrochloride(EPI). To ensure effective and safe treatment with this drug, it is essential to deal with the adverse events associated with it appropriately. At our hospital, EPI was previously administered by drip infusion(diluted with 50mL of physiological saline)over 15 minutes after pretreatment(EPI main route). With this method of treatment, venous pain and phlebitis developed in 14 of 15 cases. In 3 of these 14 cases, the regimen was modified. Following this experience, EPI administration was switched to drip infusion from the fully-opened side tube used for pretreatment(EPI sub-route). Switching to this route resulted in a sharp decrease in the incidence of venous pain and phlebitis, to only 1 of 15 cases. Stimulation of vascular tunica intima by EPI has been considered a factor principally responsible for the venous pain and phlebitis seen after EPI therapy. To prevent these adverse reactions, it is necessary to modify the method of administration so that strong or long-term exposure of blood vessels to EPI can be reduced. The results of this study suggest that the EPI sub-route we devised is useful in achieving this goal.

  12. Performance of the CONTOUR® TS Blood Glucose Monitoring System.

    PubMed

    Frank, Joy; Wallace, Jane F; Pardo, Scott; Parkes, Joan Lee

    2011-01-01

    Self-monitoring of blood glucose (SMBG) remains an important component of diabetes management, engendering a need for affordable blood glucose (BG) meters that are accurate, precise, and convenient. The CONTOUR® TS is a BG meter that endeavors to meet this need. It uses glucose dehydrogenase/flavin dinucleotide chemistry, automatic test strip calibration, and autocompensation for hematocrit along with the ease of use that has come to be expected of a modern meter. The objective of this clinical trial was to determine whether the CONTOUR TS system met these criteria. The system was evaluated at a single clinical site with 106 subjects with type 1 or type 2 diabetes. Blood glucose values ranged from 60 to 333 mg/dl over all subjects. Both lay users and health care professionals (HCPs) tested the meters, with test strips from three different lots. Results were compared to a reference analyzer of verified precision and accuracy. Forty-nine of the subjects also participated in a home study of the meter. Lay users learned to use the system without assistance and were surveyed on its use at the end of the study. When used with capillary blood, both subjects and HCPs obtained results that exceeded the International Organization for Standardization 15197:2003 criteria, (i.e., ≥95% of values fell within 20% or 15 mg/dl of the laboratory value for BG levels greater than or less than 75 mg/dl, respectively). Specifically, lay users achieved 97.9% and HCPs 98.6%. When used with venous blood, 99.8% of measurements were within the criteria. All measurements for both capillary and venous blood fell into zones A or B of the Parkes error grid, deemed clinically accurate. Hematocrit was found to have no influence on BG measurements. A large majority of the subjects found the system easy to learn and to use. The CONTOUR TS BG meter system gave accurate and reproducible results with both capillary and venous blood; subjects learned to use the meter system by following the user guide

  13. The effect of in-plane arterial curvature on blood flow and oxygen transport in arterio-venous fistulae

    NASA Astrophysics Data System (ADS)

    Iori, F.; Grechy, L.; Corbett, R. W.; Gedroyc, W.; Duncan, N.; Caro, C. G.; Vincent, P. E.

    2015-03-01

    Arterio-Venous Fistulae (AVF) are the preferred method of vascular access for patients with end stage renal disease who need hemodialysis. In this study, simulations of blood flow and oxygen transport were undertaken in various idealized AVF configurations. The objective of the study was to understand how arterial curvature affects blood flow and oxygen transport patterns within AVF, with a focus on how curvature alters metrics known to correlate with vascular pathology such as Intimal Hyperplasia (IH). If one subscribes to the hypothesis that unsteady flow causes IH within AVF, then the results suggest that in order to avoid IH, AVF should be formed via a vein graft onto the outer-curvature of a curved artery. However, if one subscribes to the hypothesis that low wall shear stress and/or low lumen-to-wall oxygen flux (leading to wall hypoxia) cause IH within AVF, then the results suggest that in order to avoid IH, AVF should be formed via a vein graft onto a straight artery, or the inner-curvature of a curved artery. We note that the recommendations are incompatible—highlighting the importance of ascertaining the exact mechanisms underlying development of IH in AVF. Nonetheless, the results clearly illustrate the important role played by arterial curvature in determining AVF hemodynamics, which to our knowledge has been overlooked in all previous studies.

  14. Arterio-venous anastomoses in the human skin and their role in temperature control

    PubMed Central

    Walløe, Lars

    2016-01-01

    ABSTRACT Arterio-venous anastomoses (AVAs) are direct connections between small arteries and small veins. In humans they are numerous in the glabrous skin of the hands and feet. The AVAs are short vessel segments with a large inner diameter and a very thick muscular wall. They are densely innervated by adrenergic axons. When they are open, they provide a low-resistance connection between arteries and veins, shunting blood directly into the venous plexuses of the limbs. The AVAs play an important role in temperature regulation in humans in their thermoneutral zone, which for a naked resting human is about 26°C to 36°C, but lower when active and clothed. From the temperature control center in the hypothalamus, bursts of nerve impulses are sent simultaneously to all AVAs. The AVAs are all closed near the lower end and all open near the upper end of the thermoneutral zone. The small veins in the skin of the arms and legs are also contracted near the lower end of the thermoneutral zone and relax to a wider cross section as the ambient temperature rises. At the cold end of the thermoneutral range, the blood returns to the heart through the deep veins and cools the arterial blood through a countercurrent mechanism. As the ambient temperature rises, more blood is returned through the superficial venous plexuses and veins and heats the skin surface of the full length of the 4 limbs. This skin surface is responsible for a large part of the loss of heat from the body toward the upper end of the thermoneutral zone. PMID:27227081

  15. Medical management of venous ulcers.

    PubMed

    Pascarella, Luigi; Shortell, Cynthia K

    2015-03-01

    Venous disease is the most common cause of chronic leg ulceration and represents an advanced clinical manifestation of venous insufficiency. Due to their frequency and chronicity, venous ulcers have a high socioeconomic impact, with treatment costs accounting for 1% of the health care budget in Western countries. The evaluation of patients with venous ulcers should include a thorough medical history for prior deep venous thrombosis, assessment for an hypercoagulable state, and a physical examination. Use of the CEAP (clinical, etiology, anatomy, pathophysiology) Classification System and the revised Venous Clinical Severity Scoring System is strongly recommended to characterize disease severity and assess response to treatment. This venous condition requires lifestyle modification, with affected individuals performing daily intervals of leg elevation to control edema; use of elastic compression garments; and moderate physical activity, such as walking wearing below-knee elastic stockings. Meticulous skin care, treatment of dermatitis, and prompt treatment of cellulitis are important aspects of medical management. The pharmacology of chronic venous insufficiency and venous ulcers include essentially two medications: pentoxifylline and phlebotropic agents. The micronized purified flavonoid fraction is an effective adjunct to compression therapy in patients with large, chronic ulceration. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Brain oxygen saturation assessment in neonates using T2-prepared blood imaging of oxygen saturation and near-infrared spectroscopy.

    PubMed

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra Ma; Hendrikse, Jeroen; Groenendaal, Floris; van Bel, Frank; Benders, Manon Jnl; Petersen, Esben T

    2017-03-01

    Although near-infrared spectroscopy is increasingly being used to monitor cerebral oxygenation in neonates, it has a limited penetration depth. The T 2 -prepared Blood Imaging of Oxygen Saturation (T 2 -BIOS) magnetic resonance sequence provides an oxygen saturation estimate on a voxel-by-voxel basis, without needing a respiratory calibration experiment. In 15 neonates, oxygen saturation measured by T 2 -prepared blood imaging of oxygen saturation and near-infrared spectroscopy were compared. In addition, these measures were compared to cerebral blood flow and venous oxygen saturation in the sagittal sinus. A strong linear relation was found between the oxygen saturation measured by magnetic resonance imaging and the oxygen saturation measured by near-infrared spectroscopy ( R 2  = 0.64, p < 0.001). Strong linear correlations were found between near-infrared spectroscopy oxygen saturation, and magnetic resonance imaging measures of frontal cerebral blood flow, whole brain cerebral blood flow and venous oxygen saturation in the sagittal sinus ( R 2  = 0.71, 0.50, 0.65; p < 0.01). The oxygen saturation obtained by T 2 -prepared blood imaging of oxygen saturation correlated with venous oxygen saturation in the sagittal sinus ( R 2  = 0.49, p = 0.023), but no significant correlations could be demonstrated with frontal and whole brain cerebral blood flow. These results suggest that measuring oxygen saturation by T 2 -prepared blood imaging of oxygen saturation is feasible, even in neonates. Strong correlations between the various methods work as a cross validation for near-infrared spectroscopy and T 2 -prepared blood imaging of oxygen saturation, confirming the validity of using of these techniques for determining cerebral oxygenation.

  17. The effect of CPAP treatment on venous lactate and arterial blood gas among obstructive sleep apnea syndrome patients.

    PubMed

    Lin, Ting; Huang, Jie-Feng; Lin, Qi-Chang; Chen, Gong-Ping; Wang, Bi-Ying; Zhao, Jian-Ming; Qi, Jia-Chao

    2017-05-01

    The aim of this observational study was to investigate the influence of continuous positive airway pressure (CPAP) on arterial blood gas and venous lactate, markers of tissue hypoxia, among obstructive sleep apnea syndrome (OSAS) patients, and determine the risk factor of serum lactate and hydrogen ion concentration (PH) in OSAS patients. One-hundred and nine patients with newly diagnosed OSAS were enrolled in the study. All individuals were treated with CPAP for one night. Venous lactate and arterial blood gas were gathered from all subjects in the morning at the end of polysomnography and the next morning after CPAP treatment. Of the 109 selected subjects, the average lactate level was 2.23 ± 0.59 mmol/L, and the mean PH, PaO 2 , and PaCO 2 were 7.380 ± 0.23, 88.14 ± 17.83 mmHg, and 38.70 ± 4.28 mmHg, respectively. Compared to baseline, lactic acid significantly decreased (2.10 ± 0.50 mmol/L, p = 0.03), while PH increased (7.388 ± 0.27, p < 0.05) after CPAP treatment. In addition, neck circumference and the polysomnographic parameters, including apnea-hypopnea index, oxygen desaturation index (ODI), mean oxygen saturation (SpO 2 ), and the percentage of sleep time with SpO 2 <90 % (TS90 %), positively correlated with lactate, while age correlated negatively with lactate (all p < 0.05). Significantly positive associations were found between age, neck circumference, and PH; furthermore, a negative correlation was found between ODI and PH. Finally, after adjusting for confounding factors, TS90 % was the major contributing predictor for elevated lactate (p < 0.05), and age was a predictor for an increase in PH (p < 0.05). The results indicated that CPAP treatment could reduce serum lactate and increase PH in OSAS patients and might alleviate acid-base balance disorders in OSAS. Furthermore, TS90 % was a risk factor for elevated lactate, and age was independently associated with PH.

  18. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    PubMed

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  19. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study

    PubMed Central

    Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.

    2015-01-01

    Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197

  20. Effects of clopidogrel with or without aspirin on the generation of extracellular vesicles in the microcirculation and in venous blood: A randomized placebo controlled trial.

    PubMed

    Traby, L; Kaider, A; Kollars, M; Eichinger, S; Wolzt, M; Kyrle, P A

    2018-05-17

    Dual-antiplatelet therapy (DAPT) is a standard strategy in acute coronary heart disease; however, it confers a considerable bleeding risk. Single-antiplatelet therapy (SAPT) inhibits haemostatic system activation ex vivo to a similar extent as DAPT. Extracellular vesicles (EV) are procoagulant and contribute to haemostatic system activation. We aimed to investigate the effect of DAPT compared with SAPT on EV. In a randomized, double-blind, placebo-controlled trial, 44 healthy volunteers received DAPT (clopidogrel + aspirin) or SAPT (clopidogrel + placebo) for 7 days. Blood was obtained from a standardized microvascular injury and through venipuncture at baseline (BL) and at 2 h, 24 h, and 8 days after treatment initiation. The number, origin, and surface expression of EV were assessed using flow cytometry. Data are given as median (quartiles). Non-parametric tests were used to evaluate the short-term (BL vs 2 h) and long-term differences (2 h to 8 days), as well as the differences between treatment groups. There was no difference either in the short-term effects on the number (×10 3  mL -1 ) of EV in microvascular blood between DAPT [BL: 1433 (653; 3184) vs 2 h: 862 (545; 2026), p = 0.39] and SAPT [(BL: 614 (552; 1402) vs 2 h: 1079 (781; 1538), p = 0.75)] or in the long-term effects. DAPT and SAPT did not exhibit differential short-term effects on the number and proportion (36% and 27% vs 55% and 36%) of platelet-derived EV. DAPT and SAPT resulted in a significant short-term increase in phosphatidylserine expression in microvascular blood. The effects of DAPT and SAPT on EV in venous blood were similar to those in microvascular blood. DAPT and SAPT have comparable effects on the amount, origin, and surface characteristics of EV. Copyright © 2018. Published by Elsevier Ltd.

  1. The echocardiographic diagnosis of totally anomalous pulmonary venous connection in the fetus.

    PubMed

    Allan, L D; Sharland, G K

    2001-04-01

    Infants with isolated totally anomalous pulmonary venous return often present severely decompensated, such that they are at high risk for surgical repair. On the other hand, if surgical repair can be safely accomplished, the outlook is usually good. Thus prenatal diagnosis would be expected to improve the prognosis for the affected child. To describe the features of isolated totally anomalous pulmonary venous drainage in the fetus. Four fetuses with isolated totally anomalous pulmonary venous connection were identified and the echocardiographic images reviewed. Measurements of the atrial and ventricular chambers and both great arteries were made and compared with normal values. Referral centre for fetal echocardiography. There were two cases of drainage to the coronary sinus, one to the right superior vena cava, and one to the inferior vena cava. Right heart dilatation relative to left heart structures was a feature of two cases early on, and became evident in some ratios late in pregnancy in the remaining two. Ventricular and great arterial disproportion in the fetus can indicate a diagnosis of totally anomalous pulmonary venous connection above the diaphragm. However, in the presence of an atrial septal defect or with infradiaphragmatic drainage, right heart dilatation may not occur until late in pregnancy. The diagnosis of totally anomalous pulmonary venous drainage in fetal life can only be reliably excluded by direct examination of pulmonary venous blood flow entering the left atrium on colour or pulsed flow mapping.

  2. A New Technique for Femoral Venous Access in Infants Using Arterial Injection Venous Return Guidance

    PubMed Central

    Ebishima, Hironori; Kitano, Masataka; Kurosaki, Kenichi; Shiraishi, Isao

    2017-01-01

    Objectives: Although venography guidance is helpful for central venous catheter placement, it is sometimes difficult to place a peripheral intravenous cannula for enhancement. We designed a new technique for establishing femoral venous access using venography guidance in the return phase of peripheral arteriography. This new technique was named arterial injection venous return guidance. Here we assessed the efficacy and safety of arterial injection venous return guidance. Methods: We reviewed data of 29 infants less than 6 months old undergoing catheter intervention at our institute in 2014. Of the 29 patients, femoral venous cannulation was performed using arterial injection venous return guidance in 5 patients, venography in 20 patients, and the landmark method in 4 patients. The technical success rates and incidence of complications were compared. Results: The overall success rates were 100% in the arterial injection venous return-guided and venography-guided groups. The mean procedure duration and mean contrast material injection time were similar between the groups. The contrast effect on the femoral vein in the arterial injection venous return-guided group was lower than that in the venography-guided group, but adequate for surgery. The overall complication rate was 17%, and obstruction of previously placed intravenous catheters was the most common complication. Conclusions: Therefore, the arterial injection venous return guidance technique was as safe and efficient as venography for establishing venous access. PMID:29034015

  3. MR Elastography Can Be Used to Measure Brain Stiffness Changes as a Result of Altered Cranial Venous Drainage During Jugular Compression.

    PubMed

    Hatt, A; Cheng, S; Tan, K; Sinkus, R; Bilston, L E

    2015-10-01

    Compressing the internal jugular veins can reverse ventriculomegaly in the syndrome of inappropriately low pressure acute hydrocephalus, and it has been suggested that this works by "stiffening" the brain tissue. Jugular compression may also alter blood and CSF flow in other conditions. We aimed to understand the effect of jugular compression on brain tissue stiffness and CSF flow. The head and neck of 9 healthy volunteers were studied with and without jugular compression. Brain stiffness (shear modulus) was measured by using MR elastography. Phase-contrast MR imaging was used to measure CSF flow in the cerebral aqueduct and blood flow in the neck. The shear moduli of the brain tissue increased with the percentage of blood draining through the internal jugular veins during venous compression. Peak velocity of caudally directed CSF in the aqueduct increased significantly with jugular compression (P < .001). The mean jugular venous flow rate, amplitude, and vessel area were significantly reduced with jugular compression, while cranial arterial flow parameters were unaffected. Jugular compression influences cerebral CSF hydrodynamics in healthy subjects and can increase brain tissue stiffness, but the magnitude of the stiffening depends on the percentage of cranial blood draining through the internal jugular veins during compression—that is, subjects who maintain venous drainage through the internal jugular veins during jugular compression have stiffer brains than those who divert venous blood through alternative pathways. These methods may be useful for studying this phenomenon in patients with the syndrome of inappropriately low-pressure acute hydrocephalus and other conditions. © 2015 by American Journal of Neuroradiology.

  4. Patterns of anomalous pulmonary venous drainage.

    PubMed

    Snellen, H A; van Ingen, H C; Hoefsmit, E C

    1968-07-01

    All of our cases of abnormal pulmonary venous connections collected to the middle of 1965 and verified at surgery or autopsy have been reviewed by means of diagrams and tabulations, using a specially devised code to facilitate the survey. The material consisted of 52 autopsy cases (half of them obtained after surgery) and the cases of 72 patients who survived operation. The postmortem group was much younger than the surgical group and differed also from the latter by showing male preponderance as well as relatively many instances of total abnormal pulmonary venous connection and frequently associated cardiac anomalies. Partial anomalous connection of right pulmonary veins was 10 times more frequent than that of the left pulmonary veins. This was caused by (1) the frequent drainage of some of the right pulmonary veins into the junctional area between right atrium and superior vena cava in the presence of normal left pulmonary veins, and (2) the complete absence of isolated left pulmonary venous connection to the right atrium. Abnormal connection of solitary pulmonary veins was always effected to the most proximal venous structure among the four possible ones which are derived from the main embryonic channels (superior vena cava and inferior vena cava on the right side, and left superior vena cava and coronary sinus on the left side). Common pulmonary veins from one lung also drained in accordance with this proximity rule, if this may be taken to apply also to the drainage of right pulmonary veins into the right atrium. The one exception in our material was the drainage of all right pulmonary veins into the portal venous system. Total abnormal pulmonary venous connection may be found with all structures mentioned, but most frequently with the left superior vena cava, or coronary sinus, or both, usually by way of a common pulmonary vein. In a few cases however, drainage into different sites, all of them abnormal, did occur. Then again the proximity rule seemed to

  5. Proximally pedicled medial plantar flap based on superficial venous system alone for venous drainage.

    PubMed

    Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L

    2013-07-01

    The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Rapid detection of D-Dimers with mLabs® whole blood method for venous thromboembolism exclusion. Comparison with Vidas® D-Dimers assay.

    PubMed

    Gerotziafas, Grigoris T; Ray, Patrick; Gkalea, Vasiliki; Benzarti, Ahlem; Khaterchi, Amir; Cast, Claire; Pernet, Julie; Lefkou, Eleftheria; Elalamy, Ismail

    2016-12-01

    Easy to use point of care assays for D-Dimers measurement in whole blood from patients with clinical suspicion of venous thromboembolism (VTE) will facilitate the diagnostic strategy in the Emergency Department (ED) setting. We prospectively evaluated the diagnostic performance of the point-of-care mLabs® Whole Blood D-Dimers test and we compared it with the Vidas® D-Dimers assay. As part of the diagnostic algorithm applied in patients with clinical suspicion of VTE, the VIDAS® D-Dimers Test was prescribed by the emergency physician in charge. The mLabs® Whole Blood D-Dimers Test was used on the same samples. All patients had undergone exploration with the recommended imaging techniques for VTE diagnosis. Both assays were performed, on 99 emergency patients (mean age was 65 years) with clinical suspicion of VTE. In 3% of patients, VTE was documented with a reference imaging technique. The Bland and Altman test showed significant agreement between the two methods. Both assays showed equal sensitivity and negative predictive value for VTE. The mLabs whole blood assay is a promising point of care method for measurement of D-Dimers and exclusion of VTE diagnosis in the emergency setting which should be validated in a larger prospective study.

  7. Evaluation of gingival blood as a minimally invasive screening tool for diabetes mellitus among 40-59-year-old adults in dental clinics: A cross-sectional study.

    PubMed

    Partheeban, Indumathi K; Chaly, Preetha; Priyadarshni, Indra; Junaid, Mohammed; Nijesh, J E; Vaishnavi, S

    2017-01-01

    To evaluate a quick, safe, and minimally invasive method to screen for diabetes using gingival blood with the help of self-monitoring glucometer during periodontal examination. A hospital-based, cross-sectional comparative study was conducted among 40-59-year-old diabetic and nondiabetic population who had come for their master health examination to a private tertiary care hospital (Global Hospital and Health City) in Chennai. Among them, those who fulfilled the inclusion criteria were selected for the study. Thirty diabetic and thirty nondiabetic patients with moderate to severe gingivitis were enrolled and subjected to routine clinical periodontal examination. Blood samples of two sites were analyzed using a glucose self-monitoring device (Accu-Check). Patients were tested for venous fasting blood sugar (VFBS), venous postprandial blood sugar (VPPS), gingival fasting blood sugar (GFBS) level, gingival postprandial blood sugar (GPPS) level, peripheral fingerstick fasting blood sugar (PFBS) level, and peripheral fingerstick postprandial sugar (PPPS) level. Data obtained were statistically analyzed using Student's t-test, ANOVA, and Pearson's correlation test. A significant positive correlation was found between GFBS and VFBS, GFBS and PFBS, GPPS and VPPS, and GPPS and PPPS (P < 0.01) in both diabetic and nondiabetic patients correlation. Using venous blood glucose level as a gold standard, the sensitivity and specificity of GFBS was 93% and 100%, respectively, whereas in GPPS, the sensitivity and specificity was 80% and 96%, respectively. Gingival blood glucometry can be used as a minimally invasive screening tool for diabetes mellitus in dental clinics.

  8. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    PubMed

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  9. Comparison of Venous Return Characteristics with Right Ventricular Mechanics During Cephalic Fluid Shift

    NASA Technical Reports Server (NTRS)

    Elliott, Morgan; Martin, David

    2015-01-01

    For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail

  10. Agreement between arterial and venous lactate in emergency department patients: a prospective study of 157 consecutive patients.

    PubMed

    Paquet, Anne-Laure; Valli, Vanina; Philippon, Anne-Laure; Devilliers, Catherine; Bloom, Ben; Hausfater, Pierre; Riou, Bruno; Freund, Yonathan

    2018-04-01

    In the emergency department (ED), lactate is routinely used for risk stratification. Whether venous or arterial lactate measured on blood gas is interchangeable is not known. We hypothesized that venous lactate can be used instead of arterial lactate for the evaluation of acute patients in the ED. This was a prospective single-center study. All patients requiring a lactate measurement were enrolled and we simultaneously drew arterial and venous blood. We followed up all patients to hospital discharge. Our primary aim was to evaluate agreements between the two measurements using Bland and Altman plots with the report of bias (mean difference) and limits of agreements. We also aimed to determine the rate of misclassification (defined as one measurement<1.8 mmol/l and the other>2.2). Our secondary aim was to evaluate their respective prognostic value to predict in-hospital death or admission in the ICU longer than 72 h. The mean age of the 132 analyzed patients was 62 years (SD: 18 years), and 59% were men. The mean difference (bias) between arterial and venous lactate was -0.6 mmol/l (limits of agreement: -1.7 to 0.6 mmol/l). The rate of misclassification was 8% (95% confidence interval: 3-2%). Both methods present similar performances for the prediction of poor outcomes, with an area under the receiving operator characteristic curves of 0.67 for both. Results were similar when focused only on septic patients. Venous and arterial lactates do not agree well, and there is a high misclassification rate. Venous lactate does not appear to be interchangeable with arterial sampling.

  11. Massive multicystic dilatation of the uterine wall with myometrial venous thrombosis during pregnancy.

    PubMed

    Uotila, J; Dastidar, P; Martikainen, P; Kirkinen, P

    2004-09-01

    We present a pregnancy complicated by multicystic dilatation of the uterine wall during the second trimester, leading to massive uterine distension, anemia and preterm Cesarean section. The cystic changes detected by ultrasound and magnetic resonance imaging involved the whole uterine wall surrounding the entire amniotic cavity. Histopathological examination revealed the benign nature of the cystic changes, which represented dilated and thrombosed venous lacunae. Disturbed venous drainage, combined with local thrombosis, was likely to have led to the collection of a large volume of blood in the uterine wall and the subsequent multicystic change of the myometrium. Copyright 2004 ISUOG

  12. Intrahepatic portosystemic venous shunt: diagnosis by color Doppler imaging.

    PubMed

    Kudo, M; Tomita, S; Tochio, H; Minowa, K; Todo, A

    1993-05-01

    Intrahepatic portosystemic venous shunt is a rare clinical entity; only 33 such cases have been reported. It may be congenital, or secondary to portal hypertension. Five patients with this disorder are presented, each of whom was diagnosed by color Doppler imaging, including waveform spectral analysis. One patient with clinical evidence of cirrhosis and portal hypertension had episodes of hepatic encephalopathy and elevated blood levels of ammonia. This patient had a large tubular shunt between the posterior branch of the portal vein and the inferior vena cava. Shunts of this type are considered to be collateral pathways which develop in the hepatic parenchyma as a result of portal hypertension. The other four patients had no evidence of liver disease, and all four evidenced an aneurysmal portohepatic venous shunt within the liver parenchyma. Shunts of this type are considered congenital. The diagnosis of intrahepatic portosystemic venous shunts was established by color Doppler imaging, which demonstrated a direct communication of color flow signals between the portal vein and hepatic vein, in addition to the characterization of the Doppler spectrum at each sampling point from a continuous waveform signal (portal vein) to a turbulent signal (aneurysmal cavity), and finally, to a biphasic waveform signal (hepatic vein). As demonstrated by the five patients, color Doppler imaging is useful in the diagnosis of an intrahepatic portosystemic hepatic venous shunt, and the measurement of shunt ratio may be useful in the follow-up and determining the therapeutic option.

  13. Temperature and blood flow distribution in the human leg during passive heat stress.

    PubMed

    Chiesa, Scott T; Trangmar, Steven J; González-Alonso, José

    2016-05-01

    The influence of temperature on the hemodynamic adjustments to direct passive heat stress within the leg's major arterial and venous vessels and compartments remains unclear. Fifteen healthy young males were tested during exposure to either passive whole body heat stress to levels approaching thermal tolerance [core temperature (Tc) + 2°C; study 1; n = 8] or single leg heat stress (Tc + 0°C; study 2; n = 7). Whole body heat stress increased perfusion and decreased oscillatory shear index in relation to the rise in leg temperature (Tleg) in all three major arteries supplying the leg, plateauing in the common and superficial femoral arteries before reaching severe heat stress levels. Isolated leg heat stress increased arterial blood flows and shear patterns to a level similar to that obtained during moderate core hyperthermia (Tc + 1°C). Despite modest increases in great saphenous venous (GSV) blood flow (0.2 l/min), the deep venous system accounted for the majority of returning flow (common femoral vein 0.7 l/min) during intense to severe levels of heat stress. Rapid cooling of a single leg during severe whole body heat stress resulted in an equivalent blood flow reduction in the major artery supplying the thigh deep tissues only, suggesting central temperature-sensitive mechanisms contribute to skin blood flow alone. These findings further our knowledge of leg hemodynamic responses during direct heat stress and provide evidence of potentially beneficial vascular alterations during isolated limb heat stress that are equivalent to those experienced during exposure to moderate levels of whole body hyperthermia. Copyright © 2016 the American Physiological Society.

  14. Risk factors for venous thrombosis associated with peripherally inserted central venous catheters

    PubMed Central

    Pan, Longfang; Zhao, Qianru; Yang, Xiangmei

    2014-01-01

    To evaluate the risk factors associated with an increased risk of symptomatic peripherally inserted central venous catheter (PICC)-related venous thrombosis. Retrospective analyses identified 2313 patients who received PICCs from 1 January 2012 to 31 December 2013. All 11 patients with symptomatic PICC-related venous thrombosis (thrombosis group) and 148 who did not have thromboses (non-thrombosis group) were selected randomly. The medical information of 159 patients (age, body mass index (BMI), diagnosis, smoking history, nutritional risk score, platelet count, leucocyte count as well as levels of D-dimer, fibrinogen, and degradation products of fibrin) were collected. Logistic regression analysis was undertaken to determine the risk factors for thrombosis. Of 2313 patients, 11 (0.47%) were found to have symptomatic PICC-related venous thrombosis by color Doppler ultrasound. Being bedridden for a long time (odds ratio [(OR]), 17.774; P=0.0017), D-dimer >5 mg/L (36.651; 0.0025) and suffering from one comorbidity (8.39; 0.0265) or more comorbidities (13.705; 0.0083) were the major risk factors for PICC-catheter related venous thrombosis by stepwise logistic regression analysis. Among 159 patients, the prevalence of PICC-associated venous thrombosis in those with ≥1 risk factor was 10.34% (12/116), in those with ≥2 risk factors was 20.41% (10/49), and in those with >3 risk factors was 26.67% (4/15). Being bedridden >72 h, having increased levels of D-dimer (>5 mg/L) and suffering from comorbidities were independent risk factors of PICC-related venous thrombosis. PMID:25664112

  15. Accuracy and User Performance Evaluation of a New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device.

    PubMed

    Bailey, Timothy S; Wallace, Jane F; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Christiansen, Mark

    2017-07-01

    The new Contour ® Plus ONE blood glucose monitoring system (BGMS) features an easy-to-use, wireless-enabled blood glucose meter that links to a smart mobile device via Bluetooth ® connectivity and can sync with the Contour ™ Diabetes app on a smartphone or tablet. The accuracy of the new BGMS was assessed in 2 studies according to ISO 15197:2013 criteria. In Study 1 (laboratory study), fingertip capillary blood samples from 100 subjects were tested in duplicate using 3 test strip lots. In Study 2 (clinical study), 134 subjects with type 1 or type 2 diabetes enrolled at 2 clinical sites. BGMS results and YSI analyzer (YSI) reference results were compared for fingertip blood obtained by untrained subjects' self-testing and for study staff-obtained fingertip, subject palm, and venous results. In Study 1, 99.0% (594/600) of combined results for all 3 test strip lots fulfilled ISO 15197:2013 Section 6.3 accuracy criteria. In Study 2, 99.2% (133/134) of subject-obtained capillary fingertip results, 99.2% (133/134) of study staff-obtained fingertip results, 99.2% (125/126) of subject-obtained palm results, and 100% (132/132) of study staff-obtained venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 95.5% (128/134) of subject-obtained fingertip self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results showed that most subjects found the BGMS easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria both in the laboratory and in a clinical setting when used by untrained subjects with diabetes.

  16. Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination.

    PubMed

    Poitout, V; Moatti-Sirat, D; Reach, G

    1992-01-01

    The feasibility of calibrating a glucose sensor by using a wearable glucose meter for blood glucose determination and moderate variations of blood glucose concentration was assessed. Six miniaturized glucose sensors were implanted in the subcutaneous tissue of conscious dogs, and the parameters used for the in vivo calibration of the sensor (sensitivity coefficient and extrapolated current in the absence of glucose) were determined from values of blood glucose and sensor response obtained during glucose infusion. (1) Venous plasma glucose level and venous total blood glucose level were measured simultaneously on the same sample, using a Beckman analyser and a Glucometer II, respectively. The regression between plasma glucose (x) and whole blood glucose (y) was y = 1.12x-0.08 mM (n = 114 values, r = 0.96, p = 0.0001). The error grid analysis indicated that the use of a Glucometer II for blood glucose determination was appropriate in dogs. (2) The in vivo sensitivity coefficients were 0.57 +/- 0.11 nA mM-1 when determined from plasma glucose, and 0.51 +/- 0.07 nA mM-1 when determined from whole blood glucose (t = 1.53, p = 0.18, n.s.). The background currents were 0.88 +/- 0.57 nA when determined from plasma glucose, and 0.63 +/- 0.77 nA when determined from whole blood glucose (t = 0.82, p = 0.45, n.s.). (3) The regression equation of the estimation of the subcutaneous glucose level obtained from the two methods was y = 1.04x + 0.56 mM (n = 171 values, r = 0.98, p = 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

  17. A novel approach to the management of critically ill neonatal Ebstein's anomaly: Veno-venous extracorporeal membrane oxygenation to promote right ventricular recovery.

    PubMed

    Bauser-Heaton, Holly; Nguyen, Charles; Tacy, Theresa; Axelrod, David

    2015-01-01

    This is the first report of the use of veno-venous extracorporeal membrane oxygenation in a neonate with severe Ebstein's anomaly. The report suggests the use of veno-venous extracorporeal membrane oxygenation in the immediate neonatal period may be a useful therapy in severe Ebstein's anomaly. By providing adequate oxygenation independent of the patient's native pulmonary blood flow, veno-venous extracorporeal membrane oxygenation allows the pulmonary vascular resistance to decrease and may promote right ventricular recovery.

  18. Comparison of Minimally and More Invasive Methods of Determining Mixed Venous Oxygen Saturation.

    PubMed

    Smit, Marli; Levin, Andrew I; Coetzee, Johan F

    2016-04-01

    To investigate the accuracy of a minimally invasive, 2-step, lookup method for determining mixed venous oxygen saturation compared with conventional techniques. Single-center, prospective, nonrandomized, pilot study. Tertiary care hospital, university setting. Thirteen elective cardiac and vascular surgery patients. All participants received intra-arterial and pulmonary artery catheters. Minimally invasive oxygen consumption and cardiac output were measured using a metabolic module and lithium-calibrated arterial waveform analysis (LiDCO; LiDCO, London), respectively. For the minimally invasive method, Step 1 involved these minimally invasive measurements, and arterial oxygen content was entered into the Fick equation to calculate mixed venous oxygen content. Step 2 used an oxyhemoglobin curve spreadsheet to look up mixed venous oxygen saturation from the calculated mixed venous oxygen content. The conventional "invasive" technique used pulmonary artery intermittent thermodilution cardiac output, direct sampling of mixed venous and arterial blood, and the "reverse-Fick" method of calculating oxygen consumption. LiDCO overestimated thermodilution cardiac output by 26%. Pulmonary artery catheter-derived oxygen consumption underestimated metabolic module measurements by 27%. Mixed venous oxygen saturation differed between techniques; the calculated values underestimated the direct measurements by between 12% to 26.3%, this difference being statistically significant. The magnitude of the differences between the minimally invasive and invasive techniques was too great for the former to act as a surrogate of the latter and could adversely affect clinical decision making. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  20. Effects of walking in deep venous thrombosis: a new integrated solid and fluid mechanics model.

    PubMed

    López, Josep M; Fortuny, Gerard; Puigjaner, Dolors; Herrero, Joan; Marimon, Francesc; Garcia-Bennett, Josep

    2017-05-01

    Deep venous thrombosis (DVT) is a common disease. Large thrombi in venous vessels cause bad blood circulation and pain; and when a blood clot detaches from a vein wall, it causes an embolism whose consequences range from mild to fatal. Walking is recommended to DVT patients as a therapeutical complement. In this study the mechanical effects of walking on a specific patient of DVT were simulated by means of an unprecedented integration of 3 elements: a real geometry, a biomechanical model of body tissues, and a computational fluid dynamics study. A set of computed tomography images of a patient's leg with a thrombus in the popliteal vein was employed to reconstruct a geometry model. Then a biomechanical model was used to compute the new deformed geometry of the vein as a function of the fiber stretch level of the semimembranosus muscle. Finally, a computational fluid dynamics study was performed to compute the blood flow and the wall shear stress (WSS) at the vein and thrombus walls. Calculations showed that either a lengthening or shortening of the semimembranosus muscle led to a decrease of WSS levels up to 10%. Notwithstanding, changes in blood viscosity properties or blood flow rate may easily have a greater impact in WSS. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Intrathoracic Pressure Regulator for Blood Loss

    DTIC Science & Technology

    2016-05-24

    AFRL-SA-WP-SR-2016-0006 Intrathoracic Pressure Regulator for Blood Loss Richard D. Branson, RRT University of Cincinnati...Special Report 3. DATES COVERED (From – To) September 2011 – October 2013 4. TITLE AND SUBTITLE Intrathoracic Pressure Regulator for Blood Loss 5a...used to treat hypovolemia and cardiac arrest. Preclinical trials demonstrate that ITPR increases venous return and thereby restores blood pressure and

  2. Intrathoracic Pressure Regulator for Blood Loss

    DTIC Science & Technology

    2016-05-01

    AFRL-SA-WP-SR-2016-0006 Intrathoracic Pressure Regulator for Blood Loss Richard D. Branson, RRT University of Cincinnati...Special Report 3. DATES COVERED (From – To) September 2011 – October 2013 4. TITLE AND SUBTITLE Intrathoracic Pressure Regulator for Blood Loss 5a...used to treat hypovolemia and cardiac arrest. Preclinical trials demonstrate that ITPR increases venous return and thereby restores blood pressure and

  3. Arterial supply, venous drainage and collateral circulation in the nose of the anaesthetized dog.

    PubMed Central

    Lung, M A; Wang, J C

    1987-01-01

    1. In pentobarbitone-anaesthetized dogs, nasal blood flows were measured with electromagnetic flow sensors. 2. The terminal internal maxillary artery was found to supply 22 +/- 2.2 ml min-1 (one side) to the nasal mucosa via the sphenopalatine and major palatine branches; the artery was found to receive multiple supply routes from common carotid, vertebral and subclavian arteries. 3. Nasal mucosa was found to receive collateral flow from contralateral terminal internal maxillary artery (about 5 to 10% of normal flow) and branches of subclavian arteries (about 36% of normal flow). 4. Nasal mucosa was found to have two venous systems: the low-flow (12 +/- 1.0 ml min-1; both sides) and low-pressure (7 +/- 0.6 mmHg) sphenopalatine veins draining the posterior nasal cavity and the high-flow (30 +/- 1.4 ml min-1; both sides) and high-pressure (17 +/- 1.0 mmHg) dorsal nasal veins draining the anterior nasal cavity. 5. PO2 of nasal venous blood was found to range from 62 +/- 2.9 mmHg to 65 +/- 3.4 mmHg. During nitrogen challenge to the nose, the sphenopalatine venous PO2 dropped to 35 +/- 3.0 mmHg while the dorsal nasal venous PO2 remained unchanged, suggesting that the sphenopalatine veins were responsible for draining capillary flow and dorsal nasal veins arteriovenous anastomotic flow as well. 6. Microscopic examination of the vascular casts confirmed that arteriovenous anastomoses were located only in the anterior nasal cavity. Images Fig. 5 Plate 1 Plate 2 PMID:3443958

  4. How High Blood Pressure Can Lead to Stroke

    MedlinePlus

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More How High Blood Pressure Can Lead to Stroke Updated:Jan 29,2018 ... stroke This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  5. Characterization of microparticles in patients with venous malformations of the head and neck.

    PubMed

    Zhu, J-Y; Ren, J-G; Zhang, W; Wang, F-Q; Cai, Y; Zhao, J-H; Chen, G; Zhao, Y-F

    2017-01-01

    To determine the basic biochemical features of microparticles (MP) in patients with venous malformation (VM) of the head and neck. Microparticles were isolated from peripheral venous blood of VM patients or healthy subjects and from lesional fluid of VM patients. Flow cytometry and real-time polymerase chain reaction were employed to determine the concentration, cellular origin, and RNA expression of obtained MP. A functional coagulation test was applied to measure the coagulant activity of MP. Circulating levels of total MP, platelet-derived MP, and endothelial MP were significantly elevated in VM patients and were consistently increased in VM patients with more extensive lesions. Lesional MP (MP from lesional fluid of VM) in VM patients were more abundant than circulating MP from VM patients or healthy subjects. Moreover, MP from VM patients displayed markedly distinct mRNA and microRNA expression compared with healthy subjects. Furthermore, MP from VM patients exhibited enhanced procoagulant activity, as evidenced by significantly shorter coagulation time. This study demonstrates for the first time that patients with VM have an altered MP profile and MP may be associated with VM-associated thrombogenesis. Further studies are required to explore the precise pathophysiological roles of MP in VM. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Exercise-induced myocardial ischemia in patients with coronary artery disease: lack of evidence for platelet activation or fibrin formation in peripheral venous blood.

    PubMed

    Marcella, J J; Nichols, A B; Johnson, L L; Owen, J; Reison, D S; Kaplan, K L; Cannon, P J

    1983-05-01

    peripheral venous blood of patients with coronary disease during exercise-induced myocardial ischemia.

  7. Prospective evaluation of chronic venous insufficiency based on foot venous pressure measurements and air plethysmography findings.

    PubMed

    Fukuoka, Masato; Sugimoto, Takaki; Okita, Yutaka

    2003-10-01

    The purpose of this study was to evaluate lower extremity venous function in patients with chronic venous insufficiency, with foot venous pressure (FVP) measurements and air plethysmography (APG). Eighty-five limbs of 63 patients with a history of chronic venous insufficiency (CVI) from 1995 to 1999 were studied. FVP parameters studied included ambulatory venous pressure (AVP), percent decrease in FVP with manual calf compression (%drop), ratio of increase in FVP over 4 seconds after release of compression (4SR%), and time to 90% recovery of FVP were measured. APG parameters studied included functional venous volume, 90% refilling time (VFT90), venous filling index, ejection fraction, and residual volume fraction. Venous filling index and 90% refilling time were significantly decreased in limbs with stasis syndrome compared with the control group. AVP, %drop, and 4SR% also showed significantly decrease in limbs with stasis syndrome compared with those without it. AVP, %drop, and 4SR% were significantly different for the primary group compared with the secondary group, whereas no differences were found with regard to any APG parameter. APG enables prediction of the presence of CVI, whereas FVP measurements are more useful for evaluation of clinical severity of CVI.

  8. Regional Blood Volume and Peripheral Blood Flow in the Postural Tachycardia Syndrome

    PubMed Central

    Stewart, Julian M.; Montgomery, Leslie D.

    2015-01-01

    Variants of postural tachycardia syndrome (POTS) are associated with increased (“high flow” POTS, HFP), decreased (“low flow POTS”, LFP) and normal (“normal flow POTS”, NFP) blood flow measured in the lower extremities while supine. We propose that postural tachycardia is related to thoracic hypovolemia during orthostasis but that the patterns of peripheral blood flow relate to different mechanisms for thoracic hypovolemia. We studied 37 POTS patients aged 14-21 years: 14 LFP, 15 NFP and 8 HFP patients and 12 healthy control subjects. Peripheral blood flow was measured supine by venous occlusion strain gauge plethysmography of the forearm and calf in order to subgroup patients. Using indocyanine green techniques we showed decreased cardiac index (CI) and increased total peripheral resistance (TPR) in LFP, increased CI and decreased TPR in HFP, and unchanged CI and TPR in NFP while supine compared to control subjects. Blood volume tended to be decreased in LFP compared to control subjects. We used impedance plethysmography to assess regional blood volume redistribution during upright tilt. Thoracic blood volume decreased while splanchnic, pelvic and leg blood volumes increased for all subjects during orthostasis, but were markedly lower than control for all POTS groups. Splanchnic volume was increased in NFP and LFP. Pelvic blood volume was increased in HFP only. Calf volume was increased above control in HFP and LFP. The results support the hypothesis of [at least] three pathophysiologic variants of POTS distinguished by peripheral blood flow related to characteristic changes in regional circulations. The data demonstrate enhanced thoracic hypovolemia during upright tilt and confirm that POTS is related to inadequate cardiac venous return during orthostasis. PMID:15117717

  9. Warfarin-induced Venous Limb Gangrene

    PubMed Central

    Grim Hostetler, Sarah; Sopkovich, Jennifer; Dean, Steven

    2012-01-01

    Warfarin is a commonly used anticoagulant that has been associated with several significant cutaneous side effects, most notably warfarin-induced skin necrosis. A lesser known adverse reaction to warfarin is warfarin-induced venous limb gangrene. Both cutaneous adverse effects share the same pathophysiology, but are clinically quite different. The majority of cases of warfarin-induced venous limb gangrene has been in patients with cancer or heparin-induced thrombocytopenia. However, other hypercoagulable disease states, such as the antiphospholipid antibody syndrome, can be associated with venous limb gangrene. In order to increase recognition of this important condition, the authors report a case of warfarin-induced venous limb gangrene in a patient with presumed antiphospholipid antibody syndrome and review the literature on warfarin-induced venous limb gangrene. PMID:23198012

  10. Microsurgical ear replantation-is venous repair necessary?-A systematic review.

    PubMed

    Momeni, Arash; Liu, Xiangxia; Januszyk, Michael; Wan, Derrick C; Buncke, Gregory M; Buntic, Rudolf F; Parrett, Brian M

    2016-05-01

    A common postoperative observation after microsurgical ear replantation has been venous congestion necessitating alternate modes of decongestion, frequently in conjunction with blood transfusion. A comprehensive literature search was performed to assess the relationship between mode of vascular reconstruction and postoperative outcome as well as postoperative transfusion requirement after microsurgical ear replantation. The search was limited to cases of microsurgical ear replantation following complete amputation. Only articles published in English and indexed in PubMed were included. The initial search retrieved 285 articles, which was narrowed down to 40 articles reporting on 60 cases that matched the aforementioned criteria. Reconstruction of the arterial and venous limb (Group 1) was performed in 63.3% of patients and artery-only anastomosis (Group 2) was performed in 31.7%. Among measurable outcomes, only the duration of surgery was significantly different between groups (2.6 hours longer in Group 1 than Group 2; P = 0.0042). In light of contemporary data demonstrating successful artery-only ear replantation, replantation should not be abandoned when unable to establish venous outflow microsurgically. © 2015 Wiley Periodicals, Inc. Microsurgery 36:345-350, 2016. © 2015 Wiley Periodicals, Inc.

  11. Postoperative complications after lower extremity arterial bypass increase the risk of new deep venous thrombosis.

    PubMed

    Aziz, Faisal; Lehman, Erik; Blebea, John; Lurie, Fedor

    2017-01-01

    Background Deep venous thrombosis after any surgical operations is considered a preventable complication. Lower extremity bypass surgery is a commonly performed operation to improve blood flow to lower extremities in patients with severe peripheral arterial disease. Despite advances in endovascular surgery, lower extremity arterial bypass remains the gold standard treatment for severe, symptomatic peripheral arterial disease. The purpose of this study is to identify the clinical risk factors associated with development of deep venous thrombosis after lower extremity bypass surgery. Methods The American College of Surgeons' NSQIP database was utilized and all lower extremity bypass procedures performed in 2013 were examined. Patient and procedural characteristics were evaluated. Univariate and multivariate logistic regression analysis was used to determine independent risk factors for the development of postoperative deep venous thrombosis. Results A total of 2646 patients (65% males and 35% females) underwent lower extremity open revascularization during the year 2013. The following factors were found to be significantly associated with postoperative deep venous thrombosis: transfusion >4 units of packed red blood cells (odds ratio (OR) = 5.21, confidence interval (CI) = 1.29-22.81, p = 0.03), postoperative urinary tract infection (OR = 12.59, CI = 4.12-38.48, p < 0.01), length of hospital stay >28 days (OR = 9.30, CI = 2.79-30.92, p < 0.01), bleeding (OR = 2.93, CI = 1.27-6.73, p = 0.01), deep wound infection (OR = 3.21, CI = 1.37-7.56, p < 0.01), and unplanned reoperation (OR = 4.57, CI = 2.03-10.26, p < 0.01). Of these, multivariable analysis identified the factors independently associated with development of deep venous thrombosis after lower extremity bypass surgery to be unplanned reoperation (OR = 3.57, CI = 1.54-8.30, p < 0.01), reintubation (OR = 8.93, CI = 2

  12. Active Ankle Movements Prevent Formation of Lower-Extremity Deep Venous Thrombosis After Orthopedic Surgery

    PubMed Central

    Li, Ye; Guan, Xiang-Hong; Wang, Rui; Li, Bin; Ning, Bo; Su, Wei; Sun, Tao; Li, Hong-Yan

    2016-01-01

    Background The aim of this study was to assess the preventive value of active ankle movements in the formation of lower-extremity deep venous thrombosis (DVT), attempting to develop a new method for rehabilitation nursing after orthopedic surgery. Material/Methods We randomly assigned 193 patients undergoing orthopedic surgery in the lower limbs into a case group (n=96) and a control group (n=97). The control group received routine nursing while the case group performed active ankle movements in addition to receiving routine nursing. Maximum venous outflow (MVO), maximum venous capacity (MVC), and blood rheology were measured and the incidence of DVT was recorded. Results On the 11th and 14th days of the experiment, the case group had significantly higher MVO and MVC than the control group (all P<0.05). The whole-blood viscosity at high shear rate and the plasma viscosity were significantly lower in the case group than in the control group on the 14th day (both P<0.05). During the experiment, a significantly higher overall DVT incidence was recorded in the control group (8 with asymptomatic DVT) compared with the case group (1 with asymptomatic DVT) (P=0.034). During follow-up, the case group presented a significantly lower DVT incidence (1 with symptomatic DVT and 4 with asymptomatic DVT) than in the control group (5 with symptomatic DVT and 10 with asymptomatic DVT) (P=0.031). Conclusions Through increasing MVO and MVC and reducing blood rheology, active ankle movements may prevent the formation of lower-extremity DVT after orthopedic surgery. PMID:27600467

  13. Simultaneous estimation of arterial and venous oxygen saturation using a camera

    NASA Astrophysics Data System (ADS)

    van Gastel, Mark; Liang, Hangbing; Stuijk, Sander; de Haan, Gerard

    2018-02-01

    Optical monitoring of arterial blood oxygenation, SpO2, using cameras has recently been shown feasible by measuring the relative amplitudes of the remotely sensed PPG waveforms captured at different wavelengths. SvO2 measures the venous blood oxygenation which together with SpO2 provides an indication of tissue oxygen consumption. In contrast to SpO2 it usually still requires a blood sample from a pulmonary artery catheter. In this work we present a method which suggests simultaneous estimation of SpO2 and SvO2 with a camera. Contrary to earlier work, our method does not require external cuffs leading to better usability and improved comfort. Since the arterial blood varies synchronously with the heart rate, all frequencies outside the heart rate band are typically filtered out for SpO2 measurements. For SvO2 estimation, we include intensity variations in the respiratory frequency range since respiration modulates venous blood due to intrathoracic pressure variations in the chest and abdomen. Consequently, under static conditions, the two dominant components in the PPG signals are respiration and pulse. By measuring the amplitude ratios of these components, it seems possible to monitor both SpO2 and SvO2 continuously. We asked healthy subjects to follow an auditory breathing pattern while recording the face and hand. Results show a difference in estimated SpO2 and SvO2 values in the range 5-30 percent for both anatomical locations, which is normal for healthy people. This continuous, non-contact, method shows promise to alert the clinician to a change in patient condition sooner than SpO2 alone.

  14. Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli

    NASA Technical Reports Server (NTRS)

    Butler, B. D.; Morris, W. P.

    1995-01-01

    Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.

  15. Study of Umbilical Cord Blood Culture in Diagnosis of Early-onset Sepsis Among Newborns with High-risk Factors.

    PubMed

    Kalathia, Mitul Babubhai; Shingala, Prakash Ashokbhai; Parmar, Parin Niranjanbhai; Parikh, Yogesh Narenedrabhai; Kalathia, Ila Mitulkumar

    2013-10-01

    Blood culture is gold standard for diagnosis of neonatal sepsis. Low sensitivity of blood culture is usually due to small volume of blood sample, intrapartum antibiotics, and antibiotics given to newborn before sampling. We evaluated use of Umbilical cord blood culture (UCBC) in diagnosis of neonatal sepsis as compared to peripheral venous blood culture. This study was done in tertiary care teaching hospital during May-June 2012. A total of 45 newborns with presence of two or more risk factors of sepsis were included. Blood sample from placental end of umbilical cord was collected and cultured. Primary outcome was diagnosis of neonatal sepsis by use of umbilical cord blood sample as compared with venous blood sample. Secondary outcome was to compare organisms identified by UCBC and venous blood culture. Sensitivity, specificity, positive and negative predictive values of UCBC were calculated. A total of 24.44% (11 out of 45) high-risk newborns had positive UCBC. A total of 17.8% (8 out of 45) newborns had positive blood culture report. Organisms grown in UCBC were Pseudomonas (45%, 5 out of 11), Acinetobacter (27.27%, 3 out of 11), Escherichia coli (18.18%, 2 out of 11), and Klebsiella (9%, 1 out of 11). UCBC is a good method for diagnosis of neonatal sepsis among high-risk newborns as compared to venous blood culture with a sensitivity of 80% and specificity of 91.43%. Organisms grown are comparable to blood culture samples.

  16. Immune Blood Sample Draw

    NASA Image and Video Library

    2012-04-26

    ISS030-E-257690 (26 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares for IMMUNE venous blood sample draws in the Columbus laboratory of the International Space Station. Following the blood draws, the samples were temporarily stowed in the Minus Eighty Laboratory Freezer for ISS 1 (MELFI-1) and later packed together with saliva samples on the Soyuz TMA-22 for return to Earth for analysis.

  17. Systemic venous drainage: can we help Newton?

    PubMed

    Corno, Antonio F

    2007-06-01

    In recent years substantial progress occurred in the techniques of cardiopulmonary bypass, but the factor potentially limiting the flexibility of cardiopulmonary bypass remains the drainage of the systemic venous return. In the daily clinical practice of cardiac surgery, the amount of systemic venous return on cardiopulmonary bypass is directly correlated with the amount of the pump flow. As a consequence, the pump flow is limited by the amount of venous return that the pump is receiving. On cardiopulmonary bypass the amount of venous drainage depends upon the central venous pressure, the height differential between patient and inlet of the venous line into the venous reservoir, and the resistance in the venous cannula(s) and circuit. The factors determining the venous return to be taken into consideration in cardiac surgery are the following: (a) characteristics of the individual patient; (b) type of planned surgical procedure; (c) type of venous cannula(s); (d) type of circuit for cardiopulmonary bypass; (e) strategy of cardiopulmonary bypass; (f) use of accessory mechanical systems to increased the systemic venous return. The careful pre-operative evaluation of all the elements affecting the systemic venous drainage, including the characteristics of the individual patient and the type of required surgical procedure, the choice of the best strategy of cardiopulmonary bypass, and the use of the most advanced materials and tools, can provide a systemic venous drainage substantially better than what it would be allowed by the simple "Law of universal gravitation" by Isaac Newton.

  18. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicholson, Tony, E-mail: Tony.Nicholson@leedsth.nhs.uk; Ettles, Duncan; Robinson, Graham

    2004-01-15

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred withmore » carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device.« less

  19. [Functional status of musculo-venous pump of shin in various types of of operations for varicose disease].

    PubMed

    Boítsov, N I; Evtikhov, R M; Potapov, N A

    1997-01-01

    Functional conditions of the muscular-venous pump of the shin were studied in 280 patients with varicose veins before surgery, in 164 patients in remote terms after various operations and in 54 healthy subjects on the base of guantitative plethysmographic estimation of hemodynamic parameters. At the stage of compensation all volume indices of the bloodflow were close to normal values; in the stage of decompensation the substantial increase of volume effectiveness and volume flow velocity was observed at carrying out the test for direct deep blood flow when walking. It was determined that in natural condition for venous hemodynamics the adaptation mechanisms of musculo-venous pump were not realized. The operation of Linton upsets the function of musculo-venous pump of the shin. The Kocket operation does not eliminate the pathologic overload when working due to insufficient radicalism in liquidation of perforation escape (steal phenomena). The subfascial ligation of perforating veins of the shin through the minor approach, used in clinical practice, proved to be sufficiently radical and does not impair the function of the musculo-venous pump of the shin.

  20. A New Procedure for Wrapped-Negative Pressure Wound Therapy for Congestion After Arterialized Venous Flap Surgery

    PubMed Central

    Niimi, Yosuke; Mori, Satoko; Takeuchi, Masaki

    2017-01-01

    Negative pressure wound therapy (NPWT) is a method for treating wound. However, there are no case reports using NPWT for treating congestion after arterialized venous flap. Therefore, this study reported favorable outcomes after using a single-use NPWT system for managing congestion. A 39-year-old man had his index finger caught by a press machine. The finger had a soft tissue defect at the ventral part. An arterialized venous flap taken from the right forearm was transplanted. Perfusion of the flap was favorable, but on postoperative day 5, congestion and the edema of the flap were found. Then, NPWT was initiated. The congestion and edema in the flap were improved without complications such as flap necrosis and wound infection. At 4 months postoperatively, the morphology of the finger was favorable. In this study, NPWT was speculated to force the deeper blood vessels within the flap to dilate with inducing drainage and the simultaneous reduction in excess blood flow to the cortical layer, resulting in the improvement of congestion. Negative pressure wound therapy was used for treating congestion after the transplantation of arterialized venous flap, and the wound was favorably managed. PMID:29270041

  1. Central venous catheters: incidence and predictive factors of venous thrombosis.

    PubMed

    Hammes, Mary; Desai, Amishi; Pasupneti, Shravani; Kress, John; Funaki, Brian; Watson, Sydeaka; Herlitz, Jean; Hines, Jane

    2015-07-01

    Central venous catheter access in an acute setting can be a challenge given underlying disease and risk for venous thrombosis. Peripherally inserted central venous catheters (PICCs) are commonly placed but limit sites for fistula creation in patients with chronic renal failure (CKD). The aim of this study is to determine the incidence of venous thrombosis from small bore internal jugular (SBIJ) and PICC line placement. This investigation identifies populations of patients who may not be ideal candidates for a PICC and highlights the importance of peripheral vein preservation in patients with renal failure. A venous Doppler ultrasound was performed at the time of SBIJ insertion and removal to evaluate for thrombosis in the internal jugular vein. Data was collected pre- and post-intervention to ascertain if increased vein preservation knowledge amongst the healthcare team led to less use of PICCs. Demographic factors were collected in the SBIJ and PICC groups and risk factor analysis was completed. 1,122 subjects had PICC placement and 23 had SBIJ placement. The incidence of thrombosis in the PICC group was 10%. One patient with an SBIJ had evidence of central vein thrombosis when the catheter was removed. Univariate and multivariate analysis demonstrated a history of transplant, and the indication of total parenteral nutrition was associated with thrombosis (p<0.001). The decrease in PICCs placed in patients with CKD 6 months before and after intervention was significant (p<0.05). There are subsets of patients ith high risk for thrombosis who may not be ideal candidates for a PICC.

  2. Cerebral venous infarction: a potentially avoidable complication of deep brain stimulation surgery.

    PubMed

    Morishita, Takashi; Okun, Michael S; Burdick, Adam; Jacobson, Charles E; Foote, Kelly D

    2013-01-01

    Despite numerous reports on the morbidity and mortality of deep brain stimulation (DBS), cerebral venous infarction has rarely been reported. We present four cases of venous infarct secondary to DBS surgery. The diagnosis of venous infarction was based on 1) delayed onset of new neurologic deficits on postoperative day 1 or 2; 2) significant edema surrounding the superficial aspect of the implanted lead, with or without subcortical hemorrhage on CT scan. Four cases (0.8% per lead, 1.3% per patient) of symptomatic cerebral venous infarction were identified out of 500 DBS lead implantation procedures between July 2002 and August 2009. All four patients had Parkinson's disease. Their DBS leads were implanted in the subthalamic nucleus (n = 2), and the globus pallidus internus (n = 2). Retrospective review of the targeting confirmed that the planned trajectory passed within 3 mm of a cortical vein in two cases for which contrast-enhanced preoperative magnetic resonance (MR) imaging was available. In the other two cases, contrasted targeting images were not obtained preoperatively. Cerebral venous infarction is a potentially avoidable, but serious complication. To minimize its incidence, we propose the use of high-resolution, contrast-enhanced, T1-weighted MR images to delineate cerebral venous anatomy, along with careful stereotactic planning of the lead trajectory to avoid injury to venous structures. © 2013 International Neuromodulation Society.

  3. External jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies.

    PubMed

    Abdullah, Mohamed Hussein; Soliman, Hossam El Deen; Morad, Wessam Saber

    2011-12-01

    Many centers have adopted central vein cannulation both for central venous pressure monitoring and fluid administration for right hepatectomy in living-liver donors. However, use of central venous catheters is associated with adverse events that are hazardous to patients and expensive to treat. This study sought to examine the use of external jugular venous pressure as an alternative to conventional central venous pressure in right lobe donor hepatectomies Forty ASA grade I adult living liver-donors without a known history of significant cardiac or pulmonary diseases were enrolled in this prospective observational study. Paired measurement of venous pressures (external jugular venous pressure and internal jugular venous pressure) were taken at the following times: after induction of anesthesia, 30 minutes after skin incision, during right lobe mobilization (every 15 minutes), during hepatic transaction (every 15 minutes), after right lobe resection (every 15 minutes), and after abdominal closure. Paired measurements were equal in 47.5%, 53.5%, 61.5%, 46.3%, and 52.5% for after induction, after skin incision, right lobe mobilization, right lobe transection, after resection, and before abdominal closure periods. However, all measurements were within acceptable limits of bias measurements (± 2 mm Hg). Central venous pressure catheter placement can be avoided and replaced by a less-invasive method such as external jugular venous pressure (which gave an acceptable estimate of central venous pressure in all phases of right lobe resection) in living-donor liver transplant and allowed equivalent monitor even during fluid restriction phases.

  4. Blood flow velocity in the popliteal vein using transverse oscillation ultrasound

    NASA Astrophysics Data System (ADS)

    Bechsgaard, Thor; Hansen, Kristoffer Lindskov; Brandt, Andreas Hjelm; Holbek, Simon; Lönn, Lars; Strandberg, Charlotte; Bækgaard, Niels; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt

    2016-04-01

    Chronic venous disease is a common condition leading to varicose veins, leg edema, post-thrombotic syndrome and venous ulcerations. Ultrasound (US) is the main modality for examination of venous disease. Color Doppler and occasionally spectral Doppler US (SDUS) are used for evaluation of the venous flow. Peak velocities measured by SDUS are rarely used in a clinical setting for evaluating chronic venous disease due to inadequate reproducibility mainly caused by the angle dependency of the estimate. However, estimations of blood velocities are of importance in characterizing venous disease. Transverse Oscillation US (TOUS), a non-invasive angle independent method, has been implemented on a commercial scanner. TOUS's advantage compared to SDUS is a more elaborate visualization of complex flow. The aim of this study was to evaluate, whether TOUS perform equal to SDUS for recording velocities in the veins of the lower limbs. Four volunteers were recruited for the study. A standardized flow was provoked with a cuff compression-decompression system placed around the lower leg. The average peak velocity in the popliteal vein of the four volunteers was 151.5 cm/s for SDUS and 105.9 cm/s for TOUS (p <0.001). The average of the peak velocity standard deviations (SD) were 17.0 cm/s for SDUS and 13.1 cm/s for TOUS (p <0.005). The study indicates that TOUS estimates lower peak velocity with improved SD when compared to SDUS. TOUS may be a tool for evaluation of venous disease providing quantitative measures for the evaluation of venous blood flow.

  5. Identification of the Upward Movement of Human CSF In Vivo and its Relation to the Brain Venous System.

    PubMed

    Dreha-Kulaczewski, Steffi; Joseph, Arun A; Merboldt, Klaus-Dietmar; Ludwig, Hans-Christoph; Gärtner, Jutta; Frahm, Jens

    2017-03-01

    CSF flux is involved in the pathophysiology of neurodegenerative diseases and cognitive impairment after traumatic brain injury, all hallmarked by the accumulation of cellular metabolic waste. Its effective disposal via various CSF routes has been demonstrated in animal models. In contrast, the CSF dynamics in humans are still poorly understood. Using novel real-time MRI, forced inspiration has been identified recently as a main driving force of CSF flow in the human brain. Exploiting technical advances toward real-time phase-contrast MRI, the current work analyzed directions, velocities, and volumes of human CSF flow within the brain aqueduct as part of the internal ventricular system and in the spinal canal during respiratory cycles. A consistent upward CSF movement toward the brain in response to forced inspiration was seen in all subjects at the aqueduct, in 11/12 subjects at thoracic level 2, and in 4/12 subjects at thoracic level 5. Concomitant analyses of CSF dynamics and cerebral venous blood flow, that is, in epidural veins at cervical level 3, uniquely demonstrated CSF and venous flow to be closely communicating cerebral fluid systems in which inspiration-induced downward flow of venous blood due to reduced intrathoracic pressure is counterbalanced by an upward movement of CSF. The results extend our understanding of human CSF flux and open important clinical implications, including concepts for drug delivery and new classifications and therapeutic options for various forms of hydrocephalus and idiopathic intracranial hypertension. SIGNIFICANCE STATEMENT Effective disposal of brain cellular waste products via CSF has been demonstrated repeatedly in animal models. However, CSF dynamics in humans are still poorly understood. A novel quantitative real-time MRI technique yielded in vivo CSF flow directions, velocities, and volumes in the human brain and upper spinal canal. CSF moved upward toward the head in response to forced inspiration. Concomitant

  6. High Blood Pressure, Afib and Your Risk of Stroke

    MedlinePlus

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More High Blood Pressure, AFib and Your Risk of Stroke Updated:Aug ... have a stroke for the first time have high blood pressure . And an irregular atrial heart rhythm — a condition ...

  7. Effect of body position and ventilation on umbilical artery and venous blood flows during delayed umbilical cord clamping in preterm lambs.

    PubMed

    Hooper, Stuart B; Crossley, Kelly J; Zahra, Valerie A; van Vonderen, Jeroen; Moxham, Alison; Gill, Andrew W; Kluckow, Martin; Te Pas, Arjan B; Wallace, Euan M; Polglase, Graeme R

    2017-07-01

    While delayed umbilical cord clamping (UCC) is thought to facilitate placental to infant blood transfusion, the physiological factors regulating flow in the umbilical arteries and veins during delayed UCC is unknown. We investigated the effects of gravity, by changing fetal height relative to the placenta, and ventilation on umbilical blood flows and the cardiovascular transition during delayed UCC at birth. Catheters and flow probes were implanted into preterm lambs (128 days) prior to delivery to measure pulmonary, carotid, umbilical artery (UaBF) and umbilical venous (UvBF) blood flows. Lambs were placed either 10 cm below or 10 cm above the ewe. Ventilation commenced 2-3 min before UCC and continued for 30 min after UCC. Gravity reduced umbilical and cerebral flows when lambs were placed below the midline, but the reduction in UaBF and UvBF was similar. Ventilation during delayed UCC reduced UvBF and UaBF by similar amounts, irrespective of the lamb's position, such that flows into and out of the placenta remained balanced. The effects of ventilation on umbilical flows were much greater than the effects of gravity, but no net placental to lamb blood transfusion could be detected under any condition. Cardiovascular parameters, cerebral oxygen kinetics and final blood volumes were similar in both groups 5 min after UCC. Gravity caused small transient effects on umbilical and cerebral flow, but given changes were similar in umbilical arteries and veins, no net placental transfusion was detected. Ventilation during delayed UCC has a markedly greater influence on cardiovascular function in the newborn. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Evaluation of two-step haemoglobin screening with HemoCue for blood donor qualification in mobile collection sites.

    PubMed

    Gómez-Simón, A; Plaza, E M; Torregrosa, J M; Ferrer-Marín, F; Sánchez-Guiu, I; Vicente, V; Lozano, M L; Rivera, J

    2014-11-01

    Inaccuracy of fingerstick haemoglobin compromises donor's health and losses blood donations. We evaluated the benefit of double haemoglobin screening with HemoCue. Blood donors underwent fingerstick screening by HemoCue and were driven for donation if capillary haemoglobin was within the regulatory range. Those failing were drawn venous blood and donated if their venous haemoglobin determined with HemoCue was acceptable. Of 276 605 donor clinic visits, 10 011 (3·6%) were assessed by two-step haemoglobin screening using HemoCue, because of low (n = 9444) or high (n = 567) capillary haemoglobin. Among these, 2561 (25·6%) were deemed eligible [recovered donations]. The recovery rate was 23·8% and 55·0% among donors presenting with low and high capillary haemoglobin, respectively. In both categories of attempted donations, capillary and venous haemoglobin with HemoCue correlated significantly in recovered donors (R(2)  ≈ 0·5-0·7) but not in deferred visits (R(2)  < 0·15). Venous haemoglobin with HemoCue and by haematological analyzer significantly correlated in all donations attempts (R(2)  ≈ 0·7). Donors presenting with low capillary haemoglobin showed small bias between capillary and venous haemoglobin by HemoCue (-2·4 ± 6·2 g/l), fingerstick haemoglobin and venous haemoglobin with counter (1·3 ± 7·3 g/l), and venous haemoglobin with HemoCue and counter (3·7 ± 3·9 g/l). This bias was slightly greater in donors with high capillary haemoglobin (-7·5 ± 7·8, 13·7 ± 7·5, and 6·2 ± 7·5, respectively). Double haemoglobin screening by HemoCue reached an accuracy of 87·3% for qualifying donors presenting with low fingerstick haemoglobin. Double haemoglobin measurement with HemoCue [fingerstick and venous blood if required] is feasible and allows a significant recovery of blood donations. © 2014 International Society of Blood Transfusion.

  9. EFFECTS OF LOW-FREQUENCY ULTRASOUND ON MICROCIRCULATION IN VENOUS LEG ULCERS

    PubMed Central

    Wollina, Uwe; Heinig, Birgit; Naumann, Gunther; Scheibe, Armin; Schmidt, Wolf-Dieter; Neugebauer, Reimund

    2011-01-01

    Background: Therapeutic low-frequency ultrasound (US) has been used for many years to improve wound healing in chronic wounds like venous leg ulcers. No human data are available for the possible effects of single US applications on microcirculation and their frequency-dependency. Aims: To investigated the role of therapeutic low-frequency US on microcirculation of venous leg ulcers in vivo. Patients and Methods: This is a pilot study on an inpatient basis. We use a newly developed low-frequency continuous-wave US-equipment composed of a US transducer based on piezo-fiber composites that allow the change of frequency. In this study, we apply US of 34 kHz, 53.5 kHz, and 75 kHz respectively. Twelve patients with chronic venous leg ulcers are analyzed. As an adjunct to good ulcer care, therapeutic US is applied, non-contacting, once a day, in a subaqual position for 10 minutes. Microcirculation is assessed in the ulcers adjacent to skin before US-therapy, immediately after the treatment and 30 minutes later. We use a micro-light guide spectrophotometer (O2C, LEA Medizintechnik GmbH, Gieίen, Germany) for calculation of blood flow velocity, hemoglobin oxygen saturation (SCO2) and relative hemoglobin concentration (rHb) in 2 and 8 mm depth. Contact-free remission spectroscopy (SkinREM3, Color Control Chemnitz GmbH, Chemnitz, Germany) allows contact free measurements in the VIS-NIR range of the spectrum (400 ± 1600 nm). Results: It is seen that therapeutic US is well tolerated. One patient dropped out from a treatment series since he developed erysipelas responding to standard antibiotic. Effects were seen at 34 kHz only. The SO2 values increased after single US application. The values for rHb were higher in the superficial layer of the wound bed (depth 2 mm) compared to deeper parts (8 mm depth). US treatment did not result in significant changes of rHb and blood cell velocity. The data obtained by remission spectroscopy disclose an increase of oxygenized hemoglobin

  10. NHEXAS PHASE I MARYLAND STUDY--LIPIDS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Lipids in Blood data set presents concentrations of cholesterol and total triglycerides in blood serum. The data set presents measurements for up to 2 lipids in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent w...

  11. Preoperative Hospitalization Is Independently Associated With Increased Risk for Venous Thromboembolism in Patients Undergoing Colorectal Surgery: A National Surgical Quality Improvement Program Database Study.

    PubMed

    Greaves, Spencer W; Holubar, Stefan D

    2015-08-01

    An important factor in the pathophysiology of venous thromboembolism is blood stasis, thus, preoperative hospitalization length of stay may be contributory to risk. We assessed preoperative hospital length of stay as a risk factor for venous thromboembolism. We performed a retrospective review of patients who underwent colorectal operations using univariate and multivariable propensity score analyses. This study was conducted at a tertiary referral hospital. Data on patients was obtained from the American College of Surgeons National Surgical Quality Improvement Program 2005-2011 Participant Use Data Files. Short-term (30-day) postoperative venous thromboembolism was measured. Our analysis included 242,670 patients undergoing colorectal surgery (mean age, 60 years; 52.9% women); of these, 72,219 (29.9%) were hospitalized preoperatively. The overall rate of venous thromboembolism was 2.07% (1.4% deep vein thrombosis, 0.5% pulmonary embolism, and 0.2% both). On multivariable analysis, the most predictive independent risk factors for venous thromboembolism were return to the operating room (OR, 1.62 (95% CI, 1.44-1.81); p < 0.001) and chronic steroid use (OR, 1.59 (95% CI, 1.41-1.80); p < 0.001); preoperative hospitalization also independently predicted venous thromboembolism (OR, 1.39 (95% CI, 1.28-1.51); p < 0.001), whereas the use of laparoscopy was protective (OR, 0.75 (95% CI, 0.67-0.83); p < 0.001). Propensity score stratification (capped at 7 days, 100 strata, area under the curve = 0.73) indicated that each day of preoperative hospitalization increased the odds of venous thromboembolism (OR, 1.42 (95% CI, 1.32-1.53); p < 0.001). All of the analyses showed a dose-response relationship between preoperative lengths of stay and risk of postoperative venous thromboembolism (p < 0.001). Patients who experienced venous thromboembolism had a higher 30-day mortality rate (3.7% vs 8.9%; p < 0.001). This study has limited potential generalizability and a retrospective

  12. [The indices of free-radical oxidation in the umbilical cord blood and placenta of inhabitants of the Altai Territory].

    PubMed

    Guliaeva, N V; Brusovanik, V I; Lazareva, N A; Libe, M L; Mikhalev, S L; Onufriev, M V; Cherniavskaia, L I

    1999-01-01

    Free-radical processes were studied in the umbilical blood and placenta of women from the regions of the Altai Territory, which were affected to different extents by nuclear tests on the Semipalatinsk grounds in 1949-1965. The data was obtained, which suggest changes of free-radical processes, from studied materials from women in labor in the regions most affected by the consequences of tests. The activity of erythrocytic superoxide dismutase was decreased, thus suggesting the formation of structural-functional defects of the erythrocytes. The data corresponds to the results obtained earlier when studying free-radical processes in the venous blood samples from female residents of the Altai Territory.

  13. Non-invasive MRI measurements of venous oxygenation, oxygen extraction fraction and oxygen consumption in neonates.

    PubMed

    De Vis, J B; Petersen, E T; Alderliesten, T; Groenendaal, F; de Vries, L S; van Bel, F; Benders, M J N L; Hendrikse, J

    2014-07-15

    Brain oxygen consumption reflects neuronal activity and can therefore be used to investigate brain development or neuronal injury in neonates. In this paper we present the first results of a non-invasive MRI method to evaluate whole brain oxygen consumption in neonates. For this study 51 neonates were included. The T1 and T2 of blood in the sagittal sinus were fitted using the 'T2 prepared tissue relaxation inversion recovery' pulse sequence (T2-TRIR). From the T1 and the T2 of blood, the venous oxygenation and the oxygen extraction fraction (OEF) were calculated. The cerebral metabolic rate of oxygen (CMRO2) was the resultant of the venous oxygenation and arterial spin labeling whole brain cerebral blood flow (CBF) measurements. Venous oxygenation was 59±14% (mean±sd), OEF was 40±14%, CBF was 14±5ml/100g/min and CMRO2 was 30±12μmol/100g/min. The OEF in preterms at term-equivalent age was higher than in the preterms and in the infants with hypoxic-ischemic encephalopathy (p<0.01). The OEF, CBF and CMRO2 increased (p<0.01, <0.05 and <0.01, respectively) with postnatal age. We presented an MRI technique to evaluate whole-brain oxygen consumption in neonates non-invasively. The measured values are in line with reference values found by invasive measurement techniques. Preterms and infants with HIE demonstrated significant lower oxygen extraction fraction than the preterms at term-equivalent age. This could be due to decreased neuronal activity as a reflection of brain development or as a result of tissue damage, increased cerebral blood flow due to immature or impaired autoregulation, or could be caused by differences in postnatal age. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Changing concepts in long-term central venous access: catheter selection and cost savings.

    PubMed

    Horattas, M C; Trupiano, J; Hopkins, S; Pasini, D; Martino, C; Murty, A

    2001-02-01

    Long-term central venous access is becoming an increasingly important component of health care today. Long-term central venous access is important therapeutically for a multitude of reasons, including the administration of chemotherapy, antibiotics, and total parenteral nutrition. Central venous access can be established in a variety of ways varying from catheters inserted at the bedside to surgically placed ports. Furthermore, in an effort to control costs, many traditionally inpatient therapies have moved to an outpatient setting. This raises many questions regarding catheter selection. Which catheter will result in the best outcome at the least cost? It has become apparent in our hospital that traditionally placed surgical catheters (ie, Hickmans and central venous ports) may no longer be the only options. The objective of this study was to explore the various modalities for establishing central venous access comparing indications, costs, and complications to guide the clinician in choosing the appropriate catheter with the best outcome at the least cost. We evaluated our institution's central venous catheter use during a 3-year period from 1995 through 1997. Data was obtained retrospectively through chart review. In addition to demographic data, specific information regarding catheter type, placement technique, indications, complications, and catheter history were recorded. Cost data were obtained from several departments including surgery, radiology, nursing, anesthesia, pharmacy, and the hospital purchasing department. During a 30-month period, 684 attempted central venous catheter insertions were identified, including 126 surgically placed central venous catheters, 264 peripherally inserted central catheters by the nursing service, and 294 radiologically inserted peripheral ports. Overall complications were rare but tended to be more severe in the surgical group. Relative cost differences between the groups were significant. Charges for peripherally inserted

  15. Prediction of venous wound healing with laser speckle imaging.

    PubMed

    van Vuuren, Timme Maj; Van Zandvoort, Carina; Doganci, Suat; Zwiers, Ineke; tenCate-Hoek, Arina J; Kurstjens, Ralph Lm; Wittens, Cees Ha

    2017-12-01

    Introduction Laser speckle imaging is used for noninvasive assessment of blood flow of cutaneous wounds. The aim of this study was to assess if laser speckle imaging can be used as a predictor of venous ulcer healing. Methods After generating the flux speckle images, three regions of interest (ROI) were identified to measure the flow. Sensitivity, specificity, negative predictive value, and positive predictive value for ulcer healing were calculated. Results In total, 17 limbs were included. A sensitivity of 92.3%, specificity of 75.0%, PPV of 80.0%, and NPV 75.0% were found in predicting wound healing based on laser speckle images. Mean flux values were lowest in the center (ROI I) and showed an increase at the wound edge (ROI II, p = 0.03). Conclusion Laser speckle imaging shows acceptable sensitivity and specificity rates in predicting venous ulcer healing. The wound edge proved to be the best probability for the prediction of wound healing.

  16. Hepatic encephalopathy caused by congenital extrahepatic portosystemic venous shunt.

    PubMed

    Ishii, Y; Inagaki, Y; Hirai, K; Aoki, T

    2000-01-01

    Congenital portosystemic venous shunt is a relatively rare disease. Recently, a 60-year-old woman was admitted to our hospital for hepatic encephalopathy caused by congenital extrahepatic portocaval shunt. She had been in good health until the onset of this event, with no liver damage and no experience of abdominal surgery or history of abdominal trauma. In May 1993, hepatic encephalopathy manifested suddenly, with the chief complaint of orthostatic disturbance. Although conservative treatment was administered during the subsequent 5 years, on admission, liver damage and slight splenomegaly were shown, for which complete resection of the shunt vessel and splenectomy were performed. Postoperatively, the patient's symptoms have been alleviated. Hepatic encephalopathy caused by congenital portosystemic venous shunt requires long-term conservative treatment, and the patient's quality of life is reduced. For this reason, surgical intervention or embolization with interventional radiology should be considered, and the maintenance of hepatic blood flow should also be considered.

  17. Chronic cerebro-spinal venous insufficiency (CCSVI) and multiple sclerosis.

    PubMed

    Ghezzi, A; Comi, G; Federico, A

    2011-02-01

    Multiple sclerosis (MS) is an inflammatory demyelinating disease of the CNS caused by the interplay of genetic and environmental factors. In the last years, it has been suggested that an abnormal venous drainage due to stenosis or malformation of the internal jugular and/or azygous veins may play a major pathogenetic role in MS. This abnormality called chronic cerebro-spinal venous insufficiency (CCSVI) could result in increased permeability of blood brain barrier, local iron deposition and secondary multifocal inflammation. In the present paper, literature data in favour and against this hypothesis are reported. A great variability of CCSVI has been found in both MS patients (ranging from 0 to 100%) and in control subjects (from 0 to 23%). This large variability is explained by methodological aspects, problems in assessing CCSVI, and differences among clinical series. It is urgent to perform appropriate epidemiological studies to define the possible relationship between CCSVI and MS.

  18. MicroRNA markers for forensic body fluid identification obtained from microarray screening and quantitative RT-PCR confirmation

    PubMed Central

    Zubakov, Dmitry; Boersma, Anton W. M.; Choi, Ying; van Kuijk, Patricia F.; Wiemer, Erik A. C.

    2010-01-01

    MicroRNAs (miRNAs) are non-protein coding molecules with important regulatory functions; many have tissue-specific expression patterns. Their very small size in principle makes them less prone to degradation processes, unlike messenger RNAs (mRNAs), which were previously proposed as molecular tools for forensic body fluid identification. To identify suitable miRNA markers for forensic body fluid identification, we first screened total RNA samples derived from saliva, semen, vaginal secretion, and venous and menstrual blood for the expression of 718 human miRNAs using a microarray platform. All body fluids could be easily distinguished from each other on the basis of complete array-based miRNA expression profiles. Results from quantitative reverse transcription PCR (RT-PCR; TaqMan) assays for microarray candidate markers confirmed strong over-expression in the targeting body fluid of several miRNAs for venous blood and several others for semen. However, no candidate markers from array experiments for other body fluids such as saliva, vaginal secretion, or menstrual blood could be confirmed by RT-PCR. Time-wise degradation of venous blood and semen stains for at least 1 year under lab conditions did not significantly affect the detection sensitivity of the identified miRNA markers. The detection limit of the TaqMan assays tested for selected venous blood and semen miRNA markers required only subpicogram amounts of total RNA per single RT-PCR test, which is considerably less than usually needed for reliable mRNA RT-PCR detection. We therefore propose the application of several stable miRNA markers for the forensic identification of blood stains and several others for semen stain identification, using commercially available TaqMan assays. Additional work remains necessary in search for suitable miRNA markers for other forensically relevant body fluids. Electronic supplementary material The online version of this article (doi:10.1007/s00414-009-0402-3) contains

  19. Continuous insulin administration via complex central venous catheter infusion tubing is another risk factor for blood glucose imbalance. A retrospective study.

    PubMed

    Maury, Eric; Vitry, Paola; Galbois, Arnauld; Ait-Oufella, Hafid; Baudel, Jean-Luc; Guidet, Bertrand; Offenstadt, Georges

    2012-06-14

    We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device. We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin]. Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71-48.8; p < 0.001). The administration of on-demand medication through tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.

  20. Non-terminal blood sampling techniques in guinea pigs.

    PubMed

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  1. IR imaging of blood circulation of patients with vascular disease

    NASA Astrophysics Data System (ADS)

    Wang, Hsin; Wade, Dwight R., Jr.; Kam, Jack

    2004-04-01

    We conducted a preliminary IR imaging study of blood circulation in patients with peripheral vascular diseases. Abnormal blood flow is common in older adults, especially those with elevated blood lipids, diabetes, hypertension, and a history of smoking. All of these conditions have a high prevalence in our population, often with more than one condition in the same individual. The differences in blood flow is revealed by temperature differences in areas of the extremities as well as other regions of the body. However, what is needed is an imaging technique that is relatively inexpensive and can reveal the blood flow in real time. The IR imaging can show detailed venous system and small tempearture changes associated with blood flow. Six patients with vascular diseases were tested in a clinic set up. Their legs and feet were imaged. We observed large temperature differences (cooling of more than 10° C) at the foot, especially toes. More valuable information were obtained from the temperature distribution maps. IR thermography is potentially a very valuable tool for medical application, especially for vascular diseases.

  2. Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study

    NASA Astrophysics Data System (ADS)

    Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.

    2002-08-01

    Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.

  3. Novel Evidence-Based Classification of Cavernous Venous Occlusive Disease.

    PubMed

    Pathak, Ram A; Rawal, Bhupendra; Li, Zhuo; Broderick, Gregory A

    2016-10-01

    The primary aim of our study was to determine whether an evidence-based rationale could categorize cavernous venous occlusive disease into mild, moderate and severe erectile dysfunction. A total of 863 patients underwent color duplex Doppler ultrasound from January 2010 to June 2013 performed by a single urologist. We identified a cohort of 75 patients (8.7%) with a diagnosis of cavernous venous occlusive disease based on a unilateral resistive index less than 0.9, and right and left peak systolic velocity 35 cm per second or less after visual sexual stimulation. At a median followup of 13 months patients were evaluated for treatment efficacy. A total of 75 patients with a median age of 60 years (range 19 to 83) and a mean body mass index of 26.3 kg/m(2) (range 19.0 to 39.3) satisfied the criteria of cavernous venous occlusive disease. When substratified into tertiles, resistive index cutoffs were obtained, including mild cavernous venous occlusive disease-81.6 to 94.0, moderate disease-72.6 to 81.5 and severe disease-59.5 to 72.5. Using these 3 groups the phosphodiesterase type 5-inhibitor failure rate (p = 0.017) and SHIM (Sexual Health Inventory for Men) score categories (1 to 10 vs 11 to 20, p = 0.030) were statistically significantly different for mild, moderate and severe cavernous venous occlusive disease. Treatment satisfaction was also statistically significantly different. Penile prosthetic placement was a more common outcome among patients with erectile dysfunction and more severe cavernous venous occlusive disease. Our retrospective analysis supports a correlation between the phosphodiesterase type 5 inhibitor failure rate, SHIM score and the rate of surgical intervention using resistive index values. Our data further suggest that an evidence-based classification of cavernous venous occlusive disease by color Doppler ultrasound is possible and can triage patients to penile prosthetic placement. Copyright © 2016 American Urological Association

  4. Imaging putative foetal cerebral blood oxygenation using susceptibility weighted imaging (SWI).

    PubMed

    Yadav, Brijesh Kumar; Krishnamurthy, Uday; Buch, Sagar; Jella, Pavan; Hernandez-Andrade, Edgar; Yeo, Lami; Korzeniewski, Steven J; Trifan, Anabela; Hassan, Sonia S; Haacke, E Mark; Romero, Roberto; Neelavalli, Jaladhar

    2018-05-01

    To evaluate the magnetic susceptibility, ∆χ v , as a surrogate marker of venous blood oxygen saturation, S v O 2 , in second- and third-trimester normal human foetuses. Thirty-six pregnant women, having a mean gestational age (GA) of 31 2/7 weeks, underwent magnetic resonance imaging (MRI). Susceptibility-weighted imaging (SWI) data from the foetal brain were acquired. ∆χ v of the superior sagittal sinus (SSS) was quantified using MR susceptometry from the intra-vascular phase measurements. Assuming the magnetic property of foetal blood, ∆χ do , is the same as that of adult blood, S v O 2 was derived from the measured Δχ v . The variation of ∆χ v and S v O 2 , as a function of GA, was statistically evaluated. The mean ∆χ v in the SSS in the second-trimester (n = 8) and third-trimester foetuses (n = 28) was found to be 0.34± 0.06 ppm and 0.49 ±0.05 ppm, respectively. Correspondingly, the derived S v O 2 values were 69.4% ±3.27% and 62.6% ±3.25%. Although not statistically significant, an increasing trend (p = 0.08) in Δχ v and a decreasing trend (p = 0.22) in S v O 2 with respect to advancing gestation was observed. We report cerebral venous blood magnetic susceptibility and putative oxygen saturation in healthy human foetuses. Cerebral oxygen saturation in healthy human foetuses, despite a slight decreasing trend, does not change significantly with advancing gestation. • Cerebral venous magnetic susceptibility and oxygenation in human foetuses can be quantified. • Cerebral venous oxygenation was not different between second- and third-trimester foetuses. • Foetal cerebral venous oxygenation does not change significantly with advancing gestation.

  5. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walser, Eric M., E-mail: walser.eric@mayo.edu

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist ofmore » catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.« less

  6. Oxygen venous embolism after the use of hydrogen peroxide during lumbar discectomy.

    PubMed

    Despond, O; Fiset, P

    1997-04-01

    The knee-prone position is commonly used for patients undergoing spinal surgery. Venous air embolism in such a position may be produced by the negative venous pressure gradient between the ambient air and the venous plexuses of the spinous process. When hydrogen peroxide is used to cleanse the wound, oxygen is produced. We report a case of suspected oxygen venous embolism during lumbar discectomy in the knee-prone position after use of H2O2. Immediately after irrigation of a discectomy wound with H2O2, a dramatic decrease of the PETCO2, blood pressure and oxygen saturation coincident with ST segment elevation occurred suggesting a coronary gas embolism. Symptomatic treatment was initiated immediately and the patient recovered without any sequelae. Although hydrogen peroxide has an innocuous reputation, cases of accidental ingestion or massive gas embolism after wound irrigation leading to death have been reported. A review of the literature suggests that many of the clinical and physiopathological features of air and oxygen emboli are similar. For both, measures of prevention and treatment of complications are similar. We argue that the use of hydrogen peroxide should be avoided during procedures where the position of the patient (sitting, knee-prone) increases the risk of gas embolism and that hydrogen peroxide is a potentially dangerous solution.

  7. Mixing problems in using indicators for measuring regional blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ushioda, E.; Nuwayhid, B.; Tabsh, K.

    A basic requirement for using indicators for measuring blood flow is adequate mixing of the indicator with blood prior to sampling the site. This requirement has been met by depositing the indicator in the heart and sampling from an artery. Recently, authors have injected microspheres into veins and sampled from venous sites. The present studies were designed to investigate the mixing problems in sheep and rabbits by means of Cardio-Green and labeled microspheres. The indicators were injected at different points in the circulatory system, and blood was sampled at different levels of the venous and arterial systems. Results show themore » following: (a) When an indicator of small molecular size (Cardio-Green) is allowed to pass through the heart chambers, adequate mixing is achieved, yielding accurate and reproducible results. (b) When any indicator (Cardio-Green or microspheres) is injected into veins, and sampling is done at any point in the venous system, mixing is inadequate, yielding flow results which are inconsistent and erratic. (c) For an indicator or large molecular size (microspheres), injecting into the left side of the heart and sampling from arterial sites yield accurate and reproducible results regardless of whether blood is sampled continuously or intermittently.« less

  8. Novel red cell indices indicating reduced availability of iron are associated with high erythropoietin concentration and low ph level in the venous cord blood of newborns.

    PubMed

    Ervasti, Mari; Sankilampi, Ulla; Heinonen, Seppo; Punnonen, Kari

    2008-08-01

    There is evidence that an elevated erythropoietin (EPO) concentration is associated with signs of iron deficient erythropoiesis. The aim of this study was to evaluate the iron status by means of novel cellular indices and serum iron markers and to determine whether these are associated with EPO and pH in the venous cord blood of 193 full-term newborns. There were positive correlations between EPO and the percentage of hypochromic red blood cells (%HYPOm) and reticulocytes (%HYPOr) [r = 0.45 (p < 0.001) and r = 0.56 (p < 0.001), respectively]. %HYPOm and %HYPOr also had negative correlations with pH [r = -0.53 (p = 0.001) and r = -0.46 (p = 0.001), respectively]. Newborns who had low pH (pH < or =7.15, n = 16) had significantly higher %HYPOm, %HYPOr, and serum transferrin receptor and transferrin concentrations in their cord blood than newborns with normal pH. Thus, in newborn cord blood, the higher number of red cells and reticulocytes with lower Hb content may have impaired the oxygen carrying capacity that has been a trigger for EPO production. Furthermore, signs of lower hemoglobinization of red cells are associated with low umbilical vein pH in the newborns, indicating an increased risk of birth asphyxia.

  9. Influence of Gravity on Blood Volume and Flow Distribution

    NASA Technical Reports Server (NTRS)

    Pendergast, D.; Olszowka, A.; Bednarczyk, E.; Shykoff, B.; Farhi, L.

    1999-01-01

    In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is

  10. Is bariatric surgery safe in patients who refuse blood transfusion?

    PubMed

    Kitahama, Seiichi; Smith, Mark D; Rosencrantz, David R; Patterson, Emma J

    2013-01-01

    A small, but significant, number of patients undergoing bariatric surgery refuse blood transfusion for religious or other personal reasons. Jehovah's Witnesses number more than 1 million members in the United States alone. The reported rates of hemorrhage vary from .5% to 4% after bariatric surgery, with transfusion required in one half of these cases. Pharmacologic prophylaxis against venous thromboembolism could further increase the perioperative bleeding risk. Our objective was to report the perioperative outcomes of bariatric surgery who refuse blood transfusion at a bariatric center of excellence, private practice in the United States. A retrospective review of all patients who refused blood transfusion when undergoing bariatric surgery during a 10-year period was conducted. Patients were identified from a prospectively maintained database by the bloodless surgery program at Legacy Good Samaritan Hospital. Data were collected on demographics, co-morbidities, laboratory values, medication use, blood loss, and 30-day complications. Thirty-five bloodless surgery patients underwent bariatric surgery from 2000 to 2009. Of these 35 patients, 21 underwent laparoscopic adjustable gastric banding and 14 Roux-en-Y gastric bypass. Before 2006, only pneumatic compression devices were applied for venous thromboembolism prophylaxis (n = 6). Subsequently, combination venous thromboembolism prophylaxis was performed with fondaparinux sodium 2.5 mg for RYGB or enoxaparin 40 mg for LAGB (n = 29). One RYGB patient developed postoperative hemorrhage requiring reoperation. No venous thromboembolisms or deaths occurred. Bariatric surgery can be performed in patients who refuse blood transfusion with acceptable postoperative morbidity. Larger studies are necessary to confirm the safety of this approach and to examine the effect of pharmacologic thromboprophylaxis in this patient group. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc

  11. Combined oral contraceptives: venous thrombosis.

    PubMed

    de Bastos, Marcos; Stegeman, Bernardine H; Rosendaal, Frits R; Van Hylckama Vlieg, Astrid; Helmerhorst, Frans M; Stijnen, Theo; Dekkers, Olaf M

    2014-03-03

    Combined oral contraceptive (COC) use has been associated with venous thrombosis (VT) (i.e., deep venous thrombosis and pulmonary embolism). The VT risk has been evaluated for many estrogen doses and progestagen types contained in COC but no comprehensive comparison involving commonly used COC is available. To provide a comprehensive overview of the risk of venous thrombosis in women using different combined oral contraceptives. Electronic databases (Pubmed, Embase, Web of Science, Cochrane, CINAHL, Academic Search Premier and ScienceDirect) were searched in 22 April 2013 for eligible studies, without language restrictions. We selected studies including healthy women taking COC with VT as outcome. The primary outcome of interest was a fatal or non-fatal first event of venous thrombosis with the main focus on deep venous thrombosis or pulmonary embolism. Publications with at least 10 events in total were eligible. The network meta-analysis was performed using an extension of frequentist random effects models for mixed multiple treatment comparisons. Unadjusted relative risks with 95% confidence intervals were reported.Two independent reviewers extracted data from selected studies. 3110 publications were retrieved through a search strategy; 25 publications reporting on 26 studies were included. Incidence of venous thrombosis in non-users from two included cohorts was 0.19 and 0.37 per 1 000 person years, in line with previously reported incidences of 0,16 per 1 000 person years. Use of combined oral contraceptives increased the risk of venous thrombosis compared with non-use (relative risk 3.5, 95% confidence interval 2.9 to 4.3). The relative risk of venous thrombosis for combined oral contraceptives with 30-35 μg ethinylestradiol and gestodene, desogestrel, cyproterone acetate, or drospirenone were similar and about 50-80% higher than for combined oral contraceptives with levonorgestrel. A dose related effect of ethinylestradiol was observed for gestodene

  12. [Assessment of blood flow in the middle cerebral artery and the umbilical artery in fetuses with umbilical venous pulsations].

    PubMed

    Borowski, Dariusz; Czuba, Bartosz; Kaczmarek, Piotr; Włoch, Agata; Pawłowicz, Paweł; Wyrwas, Dorota; Wielgos, Mirosław; Sodowski, Krzysztof; Szaflik, Krzysztof

    2006-03-01

    Umbilical venous pulsation is an important sign of hemodynamic compromise, especially during fetal heart failure and asphyxia. The aim of this study was to determine of the blow flow in the middle cerebral artery and the umbilical artery in fetuses with umbilical venous pulsations. The investigation included 18 fetuses with signs of the intrauterine growth restriction and umbilical venous pulsations after 28th weeks of gestation. We evaluated cerebral-placental ratio (CPR) and pulsation index (PI) in the middle cerebral artery (MCA) and the umbilical artery (UA). We observed brain sparring effect in all cases of analyzing fetuses. There were 77,8% of abnormal flow pattern in umbilical artery. 13 fetuses had a single pulsation pattern in umbilical vein and another 5 had double pulsation pattern. The coexistence of umbilical vein pulsation and abnormal flow pattern in umbilical artery is closely related to increased perinatal mortality.

  13. Effects of Heparin and ε-Aminocaproic Acid in Dogs on Plasmin- 125I Generation in Response to Urokinase Injections and Venous Injury

    PubMed Central

    Takeda, Y.; Parkhill, T. R.; Nakabayashi, M.

    1972-01-01

    The isotopic method described previously for quantification of plasmin- 125I by disc gel electrophoresis was modified by inclusion of euglobulin precipitation to expand its applicability to plasmas containing low radioactivity of plasmin- 125I and plasminogen- 125I. It was found that the euglobulin precipitation method precipitates 72.4±2.1 (sd)% of both plasmin- 125I and plasminogen- 125I. Using this method and plasminogen- 125I as a tracer, studies were first made of the effects of heparin and ε-aminocaproic acid in dogs on plasmin- 125I generation in responese to a single injection of urokinase and to venous injury; second, of the effects of venous occlusion and thrombosis on plasmin- 125I generation; and third, in vitro studies of plasminogen- 125I affinity to fibrin and its activation in blood clots. The venous injury was produced by the damage of venous endothelium by an injection of 90% phenol and the thrombosis by a thrombin injection into an occluded vein. Heparin and ε-aminocaproic acid under the present experimental conditions inhibited about 78 and 100%, respectively of plasmin- 125I generation by the urokinase injection. Similar inhibitory effects of heparin and ε-aminocaproic acid were observed on plasmin- 125I generation in response to venous injury. The venous occlusion caused a small degree of plasmin- 125I generation, but thrombin thrombosis did not seem to stimulate the generation of plasmin- 125I. The in vitro studies showed that plasminogen- 125I does not have a specific affinity to fibrin and is incorporated into blood clots in approximately equal concentrations as those in serum during clotting processes, and that blood clots per se do not stimulate plasmin- 125I generation. These results suggest that injured veins release considerable amounts of vascular plasminogen activators into circulation and that these play an important role in thrombus dissolution in vivo. PMID:4262519

  14. Venous pump of the calf: a study of venous and muscular pressures.

    PubMed

    Alimi, Y S; Barthelemy, P; Juhan, C

    1994-11-01

    Little data are available concerning the relation between the muscular pumping mechanism and the variation of superficial and deep venous pressure during normal action of the calf pump; therefore we undertook this study to determine the pressure values in three compartments of the calf and in the deep and the superficial venous system and to establish correlation between muscular and venous pressure. Nine healthy young women with a mean age of 23 years (range 19 to 28 years) were examined. In the same calf, a muscular catheter was placed in the deep posterior compartment (DPC), in the superficial posterior compartment (SPC), and in the anterior tibial compartment (ATC), and a vascular catheter was placed in the popliteal vein and in the greater saphenous vein (GSV). The five lines of pressure were simultaneously recorded in the following situations: at rest, during Valsalva maneuver, foot flexion, and foot extension. The situation was studied with the patient in the following positions: decubitus, sitting, standing, and squatting. A final continuous recording was carried out after the patient had been walking for 5 minutes. Mean values with standard errors of muscular and venous pressure were established in each situation. At rest and during Valsalva maneuver, the muscular pressures did not vary, whereas venous pressures increased significantly when the patient was sitting and standing. On the other hand, squatting was associated with a rise in the muscular and vein pressures. Foot flexion entailed a significant increase in the ATC pressure and a rise in the GSV pressure, whereas foot extension caused the DPC pressure to rise without venous pressure modifications. Walking was associated with an alternating increase in the DPC, SPC, GSV and popliteal vein pressures when the foot was compressed to floor followed by a significant decrease when the foot pressure was released. The variations in the deep and superficial venous pressures when the patient is sitting and

  15. Perioperative bleeding and blood transfusion are major risk factors for venous thromboembolism following bariatric surgery.

    PubMed

    Nielsen, Alexander W; Helm, Melissa C; Kindel, Tammy; Higgins, Rana; Lak, Kathleen; Helmen, Zachary M; Gould, Jon C

    2018-05-01

    Morbidly obese patients are at increased risk for venous thromboembolism (VTE) after bariatric surgery. Perioperative chemoprophylaxis is used routinely with bariatric surgery to decrease the risk of VTE. When bleeding occurs, routine chemoprophylaxis is often withheld due to concerns about inciting another bleeding event. We sought to evaluate the relationship between perioperative bleeding and postoperative VTE in bariatric surgery. The American College of Surgeons-National Surgical Quality Improvement Program (NSQIP) dataset between 2012 and 2014 was queried to identify patients who underwent bariatric surgery. Gastric bypass (n = 28,145), sleeve gastrectomy (n = 30,080), bariatric revision (n = 324), and biliopancreatic diversion procedures (n = 492) were included. Univariate and multivariate regressions were used to determine perioperative factors predictive of postoperative VTE within 30 days in patients who experience a bleeding complication necessitating transfusion. The rate of bleeding necessitating transfusion was 1.3%. Bleeding was significantly more likely to occur in gastric bypass compared to sleeve gastrectomy (1.6 vs. 1.0%) (p < 0.0001). For all surgeries, increased age, length of stay, operative time, and comorbidities including hypertension, dyspnea with moderate exertion, partially dependent functional status, bleeding disorder, transfusion prior to surgery, ASA class III/IV, and metabolic syndrome increased the perioperative bleeding risk (p < 0.05). Multivariate analysis revealed that the rate of VTE was significantly higher after blood transfusion [Odds Ratio (OR) = 4.7; 95% CI 2.9-7.9; p < 0.0001). Predictive risk factors for VTE after transfusion included previous bleeding disorder, ASA class III or IV, and COPD (p < 0.05). Bariatric surgery patients who receive postoperative blood transfusion are at a significantly increased risk for VTE. The etiology of VTE in those who are transfused is likely

  16. Technical considerations in continuous jugular venous oxygen saturation measurement.

    PubMed

    Dearden, N M; Midgley, S

    1993-01-01

    Fibreoptic reflection oximetry allows continuous in-vivo estimation of jugular venous oxygen saturation. In combination with pulse oximetry the oxygen extraction ratio SaO2-SjO2/SaO2 can be derived enabling identification of states of global luxury perfusion, normal coupling of global cerebral blood flow with global cerebral metabolism, global cerebral hypoperfusion and global cerebral ischemia. Several technical difficulties may arise affecting the accuracy of SjO2 recordings which must be recognised by the clinician before medical intervention is contemplated.

  17. A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation

    PubMed Central

    Sarach, Janine; Zschokke, Irin; Melcher, Gian A.

    2015-01-01

    Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to

  18. Venous ulcer review

    PubMed Central

    Bevis, Paul; Earnshaw, Jonothan

    2011-01-01

    Clinical question: What is the best treatment for venous ulcers? Results: Compression aids ulcer healing. Pentoxifylline can aid ulcer healing. Artificial skin grafts are more effective than other skin grafts in helping ulcer healing. Correction of underlying venous incompetence reduces ulcer recurrence. Implementation: Potential pitfalls to avoid are: Failure to exclude underlying arterial disease before application of compression.Unusual-looking ulcers or those slow to heal should be biopsied to exclude malignant transformation. PMID:21673869

  19. NHEXAS PHASE I REGION 5 STUDY--VOCS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of VOCs (volatile organic compounds) in 145 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood sample...

  20. Hydrothorax after Central Venous Catheterization

    PubMed Central

    Rudge, C. J.; Bewick, M.; McColl, I.

    1973-01-01

    Three patients are described who developed hydrothorax as a complication of central venous catheterization. Respiratory distress associated with physical signs of fluid in the chest should arouse suspicion that the venous catheter has perforated the wall of the vein. The complications of central venous catheterization are reviewed and three cases of hydrothorax are presented. Comments on the prevention of these complications, their diagnosis and treatment if they occur, are made. ImagesFIG. 1FIG. 2 PMID:4717421

  1. Thai venous stroke prognostic score: TV-SPSS.

    PubMed

    Poungvarin, Niphon; Prayoonwiwat, Naraporn; Ratanakorn, Disya; Towanabut, Somchai; Tantirittisak, Tassanee; Suwanwela, Nijasri; Phanthumchinda, Kamman; Tiamkoa, Somsak; Chankrachang, Siwaporn; Nidhinandana, Samart; Laptikultham, Somsak; Limsoontarakul, Sansern; Udomphanthuruk, Suthipol

    2009-11-01

    Prognosis of cerebral venous sinus thrombosis (CVST) has never been studied in Thailand. A simple prognostic score to predict poor prognosis of CVST has also never been reported. The authors are aiming to establish a simple and reliable prognostic score for this condition. The medical records of CVST patients from eight neurological training centers in Thailand who received between April 1993 and September 2005 were reviewed as part of this retrospective study. Clinical features included headache, seizure, stroke risk factors, Glasgow coma scale (GCS), blood pressure on arrival, papilledema, hemiparesis, meningeal irritation sign, location of occluded venous sinuses, hemorrhagic infarction, cerebrospinal fluid opening pressure, treatment options, length of stay, and other complications were analyzed to determine the outcome using modified Rankin scale (mRS). Poor prognosis (defined as mRS of 3-6) was determined on the discharge date. One hundred ninety four patients' records, 127 females (65.5%) and mean age of 36.6 +/- 14.4 years, were analyzed Fifty-one patients (26.3%) were in the poor outcome group (mRS 3-6). Overall mortality was 8.4%. Univariate analysis and then multivariate analysis using SPSS version 11.5 revealed only four statistically significant predictors influencing outcome of CVST They were underlying malignancy, low GCS, presence of hemorrhagic infarction (for poor outcome), and involvement of lateral sinus (for good outcome). Thai venous stroke prognostic score (TV-SPSS) was derived from these four factors using a multiple logistic model. A simple and pragmatic prognostic score for CVST outcome has been developed with high sensitivity (93%), yet low specificity (33%). The next study should focus on the validation of this score in other prospective populations.

  2. Monro-Kellie 2.0: The dynamic vascular and venous pathophysiological components of intracranial pressure

    PubMed Central

    2016-01-01

    For 200 years, the ‘closed box’ analogy of intracranial pressure (ICP) has underpinned neurosurgery and neuro-critical care. Cushing conceptualised the Monro-Kellie doctrine stating that a change in blood, brain or CSF volume resulted in reciprocal changes in one or both of the other two. When not possible, attempts to increase a volume further increase ICP. On this doctrine’s “truth or relative untruth” depends many of the critical procedures in the surgery of the central nervous system. However, each volume component may not deserve the equal weighting this static concept implies. The slow production of CSF (0.35 ml/min) is dwarfed by the dynamic blood in and outflow (∼700 ml/min). Neuro-critical care practice focusing on arterial and ICP regulation has been questioned. Failure of venous efferent flow to precisely match arterial afferent flow will yield immediate and dramatic changes in intracranial blood volume and pressure. Interpreting ICP without interrogating its core drivers may be misleading. Multiple clinical conditions and the cerebral effects of altitude and microgravity relate to imbalances in this dynamic rather than ICP per se. This article reviews the Monro-Kellie doctrine, categorises venous outflow limitation conditions, relates physiological mechanisms to clinical conditions and suggests specific management options. PMID:27174995

  3. Monro-Kellie 2.0: The dynamic vascular and venous pathophysiological components of intracranial pressure.

    PubMed

    Wilson, Mark H

    2016-08-01

    For 200 years, the 'closed box' analogy of intracranial pressure (ICP) has underpinned neurosurgery and neuro-critical care. Cushing conceptualised the Monro-Kellie doctrine stating that a change in blood, brain or CSF volume resulted in reciprocal changes in one or both of the other two. When not possible, attempts to increase a volume further increase ICP. On this doctrine's "truth or relative untruth" depends many of the critical procedures in the surgery of the central nervous system. However, each volume component may not deserve the equal weighting this static concept implies. The slow production of CSF (0.35 ml/min) is dwarfed by the dynamic blood in and outflow (∼700 ml/min). Neuro-critical care practice focusing on arterial and ICP regulation has been questioned. Failure of venous efferent flow to precisely match arterial afferent flow will yield immediate and dramatic changes in intracranial blood volume and pressure. Interpreting ICP without interrogating its core drivers may be misleading. Multiple clinical conditions and the cerebral effects of altitude and microgravity relate to imbalances in this dynamic rather than ICP per se. This article reviews the Monro-Kellie doctrine, categorises venous outflow limitation conditions, relates physiological mechanisms to clinical conditions and suggests specific management options. © The Author(s) 2016.

  4. Whole blood flow cytometry measurements of in vivo platelet activation in critically-Ill patients are influenced by variability in blood sampling techniques.

    PubMed

    Rondina, Matthew T; Grissom, Colin K; Men, Shaohua; Harris, Estelle S; Schwertz, Hansjorg; Zimmerman, Guy A; Weyrich, Andrew S

    2012-06-01

    Flow cytometry is often used to measure in vivo platelet activation in critically-ill patients. Variability in blood sampling techniques, which may confound these measurements, remains poorly characterized. Platelet activation was measured by flow cytometry performed on arterial and venous blood from 116 critically-ill patients. We determined how variability in vascular sampling site, processing times, and platelet counts influenced levels of platelet-monocyte aggregates (PMA), PAC-1 binding (for glycoprotein (GP) IIbIIIa), and P-selectin (P-SEL) expression. Levels of PMA, but not PAC-1 binding or P-SEL expression, were significantly affected by variability in vascular sampling site. Average PMA levels were approximately 60% higher in whole blood drawn from an arterial vessel compared to venous blood (16.2±1.8% vs. 10.7±1.2%, p<0.05). Levels of PMA in both arterial and venous blood increased significantly during ex vivo processing delays (1.7% increase for every 10 minute delay, p<0.05). In contrast, PAC-1 binding and P-SEL expression were unaffected by processing delays. Levels of PMA, but not PAC-1 binding or P-SEL expression, were correlated with platelet count quartiles (9.4±1.6% for the lowest quartile versus 15.4±1.6% for the highest quartile, p<0.05). In critically-ill patients, variability in vascular sampling site, processing times, and platelet counts influence levels of PMA, but not PAC-1 binding or P-SEL expression. These data demonstrate the need for rigorous adherence to blood sampling protocols, particularly when levels of PMA, which are most sensitive to variations in blood collection, are measured for detection of in vivo platelet activation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    PubMed

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Healing process of venous ulcers: the role of microcirculation.

    PubMed

    Ambrózy, Ewald; Waczulíková, Iveta; Willfort, Andrea; Böhler, Kornelia; Cauza, Karla; Ehringer, Herbert; Heinz, Gottfried; Koppensteiner, Renate; Marić, Snezana; Gschwandtner, Michael E

    2013-02-01

    In order to describe adequately the process of healing in the intermediate degrees, we investigated microcirculatory changes in the venous ulcers at well-defined stages of wound repair. We investigated dynamic changes in microcirculation during the healing process of venous ulcers. Ten venous ulcers were investigated in three consecutive clinical stages of wound healing: non granulation tissue (NGTA), GTA and scar. Subpapillary microcirculation was measured by laser Doppler perfusion (LDP) imaging and expressed using LDP values in arbitrary units. Nutritive perfusion by capillary microscopy and expressed as capillary density (CD) - the number of capillaries per square millimetre. Before the development of GTA the LDP was low (median 1·35; lower-upper quartiles 0·71-1·83) accompanied with zero CD in all but one patient who had a density of 1. With the first appearance of GTA in the same area, the LDP was improved (2·22; 1·12-2·33; P = 0·0024) when compared with NGTA, in combination with a significant increase in CD (1·75; 0-3; P = 0·0054). In scar, the LDP was similar to that in the NGTA (1·03; 0·77-1·83; P = 0·278), combined with the highest CD (5·75; 4·5-8) in comparison with the previous stages of the area (for both pairs, P < 0·0001). Venous ulcers are caused by poor nutritive and subpapillary perfusion. Subpapillary perfusion plays a major role in the formation of GTA. In a scar, the increased nutritive perfusion is sufficient to cover the blood supply and keep skin viable while subpapillary perfusion is low. © 2012 The Authors. International Wound Journal © 2012 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  7. The effect of vein repair on the risk of venous thromboembolic events: a review of more than 100 traumatic military venous injuries.

    PubMed

    Quan, Reagan W; Gillespie, David L; Stuart, Rory P; Chang, Audrey S; Whittaker, David R; Fox, Charles J

    2008-03-01

    The management of venous trauma remains controversial. Critics of venous repair have cited an increased incidence of associated venous thromboembolic events with this management. We analyzed the current treatment of wartime venous injuries in United States military personnel in an effort to answer this question. From December 1, 2001, to October 31, 2005, all United States casualties with named venous injuries were evaluated. A retrospective review of a clinical database was performed on demographics, mechanism of injury, associated injuries, treatment, outcomes, and venous thromboembolic events. Data were analyzed using the Fisher exact test, analysis of variance, and logarithmic transformation. During this 5-year period, 82 patients sustained 103 named venous injuries due to combat operations. All patients were male, with an average age of 27.9 years (range, 20.3-58.3 years). Blast injuries accounted for 54 venous injuries (65.9%), gunshot wounds for 25 (30.5%), and motor vehicle accidents for 3 (3.6%). The venous injury was isolated in 28 patients (34.1%), and 16 (19.5%) had multiple venous injuries. The venous injury in two patients was associated with acute phlegmasia, with fractures in 33 (40.2%), and 22 (28.1%) sustained neurologic deficits. Venous injuries were treated by ligation in 65 patients (63.1%) and by open surgical repair in 38 (36.9%). Postoperative extremity edema occurred in all patients irrespective of method of management. Thrombosis after venous repair occurred in six of the 38 cases (15.8%). Pulmonary emboli developed in three patients, one after open repair and two after ligation (P > .99). In the largest review of military venous trauma in more than three decades, we found no difference in the incidence of venous thromboembolic complications between venous injuries managed by open repair vs ligation. Blast injuries of the extremities have caused most of the venous injuries. Ligation is the most common modality of treatment in combat zones

  8. NHEXAS PHASE I REGION 5 STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    This data set includes analytical results for measurements of metals in 165 blood samples. These samples were collected to examine the relationships between personal exposure measurements, environmental measurements, and body burden. Venous blood samples were collected by venipun...

  9. Managing Stress to Control High Blood Pressure

    MedlinePlus

    ... Venous Thromboembolism Aortic Aneurysm More Managing Stress to Control High Blood Pressure Updated:Jan 29,2018 The ... limits. Reduce stress by recognizing where you have control You can’t control all the outside events ...

  10. Plasmapheresis affects responses of slowly and rapidly adapting airway receptors to pulmonary venous congestion in dogs.

    PubMed Central

    Kappagoda, C T; Ravi, K

    1989-01-01

    1. The effects of plasmapheresis on the responses of rapidly adapting receptors (RARs) and slowly adapting receptors (SARs) of the airways to pulmonary venous congestion were examined in dogs anaesthetized with alpha-chloralose. Pulmonary venous congestion was produced in a graded manner by partial obstruction of the mitral valve sufficient to raise the mean left atrial pressure by 5, 10 and 15 mmHg. Plasmapheresis was performed by withdrawing 10% of blood volume twice. 2. Both RARs (n = 11) and SARs (n = 5) responded to pulmonary venous congestion by increasing their activities. The responses of the former were proportionately greater. 3. After plasmapheresis which reduced the concentration of plasma proteins by 12.3 +/- 1.0%, the responses of the RARs to pulmonary venous congestion were enhanced significantly. There was no significant change in the responses of SARs. 4. In another set of six RARs, the effects of graded pulmonary venous congestion were investigated twice with an interval of 45 min between the two observations. No significant differences were noted between the two responses. 5. Collection of lymph from the tracheobronchial lymph duct (n = 6) showed that after plasmapheresis, there was an increase in the control lymph flow. In addition, the lymph flow was enhanced during pulmonary venous congestion (mean left atrial pressure increased by 10 mmHg). 6. It is suggested that a natural stimulus for the excitation of the RAR is a function of the fluid fluxes in the pulmonary extravascular space. PMID:2607464

  11. Numerical Simulations of Blood Flows in the Left Atrium

    NASA Astrophysics Data System (ADS)

    Zhang, Lucy

    2008-11-01

    A novel numerical technique of solving complex fluid-structure interactions for biomedical applications is introduced. The method is validated through rigorous convergence and accuracy tests. In this study, the technique is specifically used to study blood flows in the left atrium, one of the four chambers in the heart. Stable solutions are obtained at physiologic Reynolds numbers by applying pulmonary venous inflow, mitral valve outflow and appropriate constitutive equations to closely mimic the behaviors of biomaterials. Atrial contraction is also implemented as a time-dependent boundary condition to realistically describe the atrial wall muscle movements, thus producing accurate interactions with the surrounding blood. From our study, the transmitral velocity, filling/emptying velocity ratio, durations and strengths of vortices are captured numerically for sinus rhythms (healthy heart beat) and they compare quite well with reported clinical studies. The solution technique can be further used to study heart diseases such as the atrial fibrillation, thrombus formation in the chamber and their corresponding effects in blood flows.

  12. Cardiovascular regulatory response to lower body negative pressure following blood volume loss

    NASA Technical Reports Server (NTRS)

    Shimizu, M.; Ghista, D. N.; Sandler, H.

    1979-01-01

    An attempt is made to explain the cardiovascular regulatory responses to lower body negative pressure (LBNP) stress, both in the absence of and following blood or plasma volume loss, the latter being factors regularly observed with short- or long-term recumbency or weightlessness and associated with resulting cardiovascular deconditioning. Analytical expressions are derived for the responses of mean venous pressure and blood volume pooled in the lower body due to LBNP. An analysis is presented for determining the HR change due to LBNP stress following blood volume loss. It is concluded that the reduced orthostatic tolerance following long-term space flight or recumbency can be mainly attributed to blood volume loss, and that the associated cardiovascular responses characterizing this orthostatic intolerance is elicited by the associated central venous pressure response.

  13. Hybrid model of arm for analysis of regional blood oxygenation in non-invasive optical diagnostics

    NASA Astrophysics Data System (ADS)

    Nowocień, Sylwester; Mroczka, Janusz

    2017-06-01

    The paper presents a new comprehensive approach to modeling and analysis of processes occurring during the blood flow in the arm's small vessels as well as non-invasive measurement method of mixed venous oxygen saturation. During the work, a meta-analysis of available physiological data was performed and based on its result a hybrid model of forearm vascular tree was proposed. The model, in its structure, takes into account a classical nonlinear hydro-electric analogy in conjunction with light-tissue interaction. Several geometries of arm vascular tree obtained from magnetic resonance angiography (MRA) image were analyzed which allowed to proposed the structure of electrical analog network. Proposed model allows to simulate the behavior of forearm blood flow from the vascular tree mechanics point of view, as well as effects of the impact of cuff and vessel wall mechanics on the recorded photoplethysmographic signals. In particular, it allows to analyze the reaction and anatomical effects in small vessels and microcirculation caused by occlusive maneuver in selected techniques, what was of particular interest to authors and motivation to undertake research in this area. Preliminary studies using proposed model showed that inappropriate selection of occlusion maneuver parameters (e.g. occlusion time, cuff pressure etc.), cause dangerous turbulence of blood flow in the venous section of the vascular tree.

  14. A survey of the European Venous Forum on education and training in venous surgery and phlebology in Europe.

    PubMed

    Spanos, K; De Maeseneer, M; Nicolaides, A; Giannoukas, A D

    2015-04-01

    Venous training in Europe is lacking a formal curriculum among various specialties related to management of venous diseases. We conducted a survey in order to have a snapshot on the actual education and training level among physicians practicing currently venous surgery and phlebology in Europe. From April 7, 2014 to June 11, 2014 a survey was carried out using the Survey Monkey system, including 11 main questions covering all the domains of training and education in venous surgery and phlebology. The questionnaire was sent to all physicians included in the current mailing list of the European Venous Forum (EVF) and the Mediterranean League of Angiology and Vascular Surgery. Two questions were particularly addressed to those physicians who had attended the EVF hands-on workshop (HOW) at least once. The response rate was 24% (97/400) and 51.5% of them were practicing in a hospital service. Most responders were vascular surgeons (67.7%), followed by angiologists (19.4%). Only half of the responders felt as being competent to manage the whole spectrum of venous diseases successfully after completion of their training, while a few were able to perform endovenous ablations and even less more advanced venous interventions. Formal training in Duplex ultrasound was undertaken only in 55.2%. The majority suggested that a venous training program should be a separate part of their specialty rotation and should be organized at a national or European level, or even by a specific scientific society. Over 95% of those physicians who already participated in the EVF HOW considered the knowledge they acquired there as useful for their practice. There is currently an important need for more specialized venous training for all physicians involved in the diagnosis and management of venous diseases. Therefore all local, national and international initiatives should be encouraged to improve education in this field.

  15. A pseudo-three-dimensional model for quantification of oxygen diffusion from preglomerular arteries to renal tissue and renal venous blood.

    PubMed

    Lee, Chang-Joon; Ngo, Jennifer P; Kar, Saptarshi; Gardiner, Bruce S; Evans, Roger G; Smith, David W

    2017-08-01

    To assess the physiological significance of arterial-to-venous (AV) oxygen shunting, we generated a new pseudo-three-dimensional computational model of oxygen diffusion from intrarenal arteries to cortical tissue and veins. The model combines the 11 branching levels (known as "Strahler" orders) of the preglomerular renal vasculature in the rat, with an analysis of an extensive data set obtained using light microscopy to estimate oxygen mass transfer coefficients for each Strahler order. Furthermore, the AV shunting model is now set within a global oxygen transport model that includes transport from arteries, glomeruli, peritubular capillaries, and veins to tissue. While a number of lines of evidence suggest AV shunting is significant, most importantly, our AV oxygen shunting model predicts AV shunting is small under normal physiological conditions (~0.9% of total renal oxygen delivery; range 0.4-1.4%), but increases during renal ischemia, glomerular hyperfiltration (~2.1% of total renal oxygen delivery; range 0.84-3.36%), and some cardiovascular disease states (~3.0% of total renal oxygen delivery; range 1.2-4.8%). Under normal physiological conditions, blood Po 2 is predicted to fall by ~16 mmHg from the root of the renal artery to glomerular entry, with AV oxygen shunting contributing ~40% and oxygen diffusion from arteries to tissue contributing ~60% of this decline. Arterial Po 2 is predicted to fall most rapidly from Strahler order 4 , under normal physiological conditions. We conclude that AV oxygen shunting normally has only a small impact on renal oxygenation, but may exacerbate renal hypoxia during renal ischemia, hyperfiltration, and some cardiovascular disease states. Copyright © 2017 the American Physiological Society.

  16. NHEXAS PHASE I MARYLAND STUDY--PESTICIDES IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Pesticides in Blood Serum data set contains analytical results for measurements of up to 17 pesticides in 358 blood samples over 79 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were ge...

  17. Maximal venous outflow velocity: an index for iliac vein obstruction.

    PubMed

    Jones, T Matthew; Cassada, David C; Heidel, R Eric; Grandas, Oscar G; Stevens, Scott L; Freeman, Michael B; Edmondson, James D; Goldman, Mitchell H

    2012-11-01

    Leg swelling is a common cause for vascular surgical evaluation, and iliocaval obstruction due to May-Thurner syndrome (MTS) can be difficult to diagnose. Physical examination and planar radiographic imaging give anatomic information but may miss the fundamental pathophysiology of MTS. Similarly, duplex ultrasonographic examination of the legs gives little information about central impedance of venous return above the inguinal ligament. We have modified the technique of duplex ultrasonography to evaluate the flow characteristics of the leg after tourniquet-induced venous engorgement, with the objective of revealing iliocaval obstruction characteristic of MTS. Twelve patients with signs and symptoms of MTS were compared with healthy control subjects for duplex-derived maximal venous outflow velocity (MVOV) after tourniquet-induced venous engorgement of the leg. The data for healthy control subjects were obtained from a previous study of asymptomatic volunteers using the same MVOV maneuvers. The tourniquet-induced venous engorgement mimics that caused during vigorous exercise. A right-to-left ratio of MVOV was generated for patient comparisons. Patients with clinical evidence of MTS had a mean right-to-left MVOV ratio of 2.0, asymptomatic control subjects had a mean ratio of 1.3, and MTS patients who had undergone endovascular treatment had a poststent mean ratio of 1.2 (P = 0.011). Interestingly, computed tomography and magnetic resonance imaging results, when available, were interpreted as positive in only 53% of the patients with MTS according to both our MVOV criteria and confirmatory venography. After intervention, the right-to-left MVOV ratio in the MTS patients was found to be reduced similar to asymptomatic control subjects, indicating a relief of central venous obstruction by stenting the compressive MTS anatomy. Duplex-derived MVOV measurements are helpful for detection of iliocaval venous obstruction, such as MTS. Right-to-left MVOV ratios and

  18. Prevalence of difficult venous access and associated risk factors in highly complex hospitalised patients.

    PubMed

    Armenteros-Yeguas, Victoria; Gárate-Echenique, Lucía; Tomás-López, Maria Aranzazu; Cristóbal-Domínguez, Estíbaliz; Moreno-de Gusmão, Breno; Miranda-Serrano, Erika; Moraza-Dulanto, Maria Inmaculada

    2017-12-01

    To estimate the prevalence of difficult venous access in complex patients with multimorbidity and to identify associated risk factors. In highly complex patients, factors like ageing, the need for frequent use of irritant medication and multiple venous catheterisations to complete treatment could contribute to exhaustion of venous access. A cross-sectional study was conducted. 'Highly complex' patients (n = 135) were recruited from March 2013-November 2013. The main study variable was the prevalence of difficult venous access, assessed using one of the following criteria: (1) a history of difficulties obtaining venous access based on more than two attempts to insert an intravenous line and (2) no visible or palpable veins. Other factors potentially associated with the risk of difficult access were also measured (age, gender and chronic illnesses). Univariate analysis was performed for each potential risk factor. Factors with p < 0·2 were then included in multivariable logistic regression analysis. Odds ratios were also calculated. The prevalence of difficult venous access was 59·3%. The univariate logistic regression analysis indicated that gender, a history of vascular access complications and osteoarticular disease were significantly associated with difficult venous access. The multivariable logistic regression showed that only gender was an independent risk factor and the odds ratios was 2·85. The prevalence of difficult venous access is high in this population. Gender (female) is the only independent risk factor associated with this. Previous history of several attempts at catheter insertion is an important criterion in the assessment of difficult venous access. The prevalence of difficult venous access in complex patients is 59·3%. Significant risk factors include being female and a history of complications related to vascular access. © 2017 John Wiley & Sons Ltd.

  19. Percutaneous bioprosthetic venous valve: a long-term study in sheep.

    PubMed

    Pavcnik, Dusan; Uchida, Barry T; Timmermans, Hans A; Corless, Christopher L; O'Hara, Michael; Toyota, Naoyuki; Moneta, Gregory L; Keller, Frederick S; Rösch, Josef

    2002-03-01

    A long-term evaluation of a new percutaneously placed bioprosthetic, bicuspid venous valve (BVV) consisting of a square stent and small intestinal submucosa (SIS) covering was performed in 12 sheep. Of 26 BVVs placed into the jugular veins, 25 exhibited good valve function on immediate venography and 22 on venograms obtained before the sheep were killed. Gross and histologic examination results demonstrated incorporation of remodeled and endothelialized SIS BVVs into the vein wall. Slight to moderate leaflet thickening was found mostly at their bases. Percutaneously placed SIS BVV is a promising one-way, competent valve that resists venous back-pressure while allowing forward flow.

  20. High-affinity hemoglobin and blood oxygen saturation in diving emperor penguins.

    PubMed

    Meir, Jessica U; Ponganis, Paul J

    2009-10-01

    The emperor penguin (Aptenodytes forsteri) thrives in the Antarctic underwater environment, diving to depths greater than 500 m and for durations longer than 23 min. To examine mechanisms underlying the exceptional diving ability of this species and further describe blood oxygen (O2) transport and depletion while diving, we characterized the O2-hemoglobin (Hb) dissociation curve of the emperor penguin in whole blood. This allowed us to (1) investigate the biochemical adaptation of Hb in this species, and (2) address blood O2 depletion during diving, by applying the dissociation curve to previously collected partial pressure of O2 (PO2) profiles to estimate in vivo Hb saturation (SO2) changes during dives. This investigation revealed enhanced Hb-O2 affinity (P50=28 mmHg, pH 7.5) in the emperor penguin, similar to high-altitude birds and other penguin species. This allows for increased O2 at low blood PO2 levels during diving and more complete depletion of the respiratory O2 store. SO2 profiles during diving demonstrated that arterial SO2 levels are maintained near 100% throughout much of the dive, not decreasing significantly until the final ascent phase. End-of-dive venous SO2 values were widely distributed and optimization of the venous blood O2 store resulted from arterialization and near complete depletion of venous blood O2 during longer dives. The estimated contribution of the blood O2 store to diving metabolic rate was low and highly variable. This pattern is due, in part, to the influx of O2 from the lungs into the blood during diving, and variable rates of tissue O2 uptake.

  1. Relative blood volume measurements by magnetic resonance imaging facilitate detection of testicular torsion.

    PubMed

    Cheng, H C; Khan, M A; Bogdanov, A; Kwong, K; Weissleder, R

    1997-12-01

    The authors determine the utility of relative blood volume measurements (rBV) using a blood pool marker for magnetic resonance imaging (MRI) in detection of early testicular torsion. Testicular torsion was induced in rats by counterclockwise 720 degrees rotation and fixation of the testis in the scrotum. MPEG-PL-DTPA-Gd enhanced MRI (30 mumol Gd/kg bolus injection) was performed 1 hour after torsion at 1.5 T using fat-suppressed three-dimensional fast spoiled gradient-recalled sequence for relative blood volume measurement and three-dimensional time-of-flight sequence for MR angiography (MRA). The rBV of the torqued testes was significantly lower (13.3% +/- 13.5%) than that of testes with sham operation (97.7% +/- 5.3%; P < 0.05). Rats with testicular torsion showed larger regions of ischemia than did animals with sham operation (63.4% +/- 13.0% versus 4.0% +/- 2.8% of all pixels in testis; P < 0.01). The MRA of testicular torsion showed engorgement of the distal testicular vein as a sign of venous compression or total disappearance of the testicular vein, indicating arterial insufficiency. The authors conclude that MPEG-PL-DTPA-Gd can be used to obtain functional (rBV), morphologic (tunica enhancement), and angiographic (venous engorgement, arterial compromise) findings that should improve the diagnosis of testicular torsion in the acute setting.

  2. Central venous catheter infection-related glomerulonephritis under long-term parenteral nutrition: a report of two cases.

    PubMed

    Okada, Mari; Sato, Mai; Ogura, Masao; Kamei, Koichi; Matsuoka, Kentaro; Ito, Shuichi

    2016-03-31

    Advances in long-term parenteral nutrition via indwelling central venous catheter have improved the quality of life and mortality in patients with life-threatening gastrointestinal diseases complicated with severely impaired absorption. However, infection to central venous catheter is still a common and critical complication for such patients. We encountered two patients under long-term parenteral nutrition who developed glomerulonephritis associated with central venous catheter infection. Persistent bacterial infection in indwelling medical devices placed in the blood-stream such as a ventricular-atrial shunt is known to cause glomerulonephritis, a condition termed shunt nephritis. We reported the clinical manifestations, treatment and their pathological findings in the two patients with glomerulonephritis associated with central venous catheter infection. Both patients suffered from megacystis microcolon intestinal hypoperistalsis syndrome, a form of pseudo-Hirschsprung's disease. They had been receiving home parenteral nutrition via central venous catheter because of severe malabsorption. They presented proteinuria, hematuria, hypocomplementemia and positive PR3-antineutrophilic cytoplasmic antibody accompanied by Staphylococcus epidermidis infection in the central venous catheter. Their renal biopsy revealed membranoproliferative glomerulonephritis with positive C3 deposition. One of them recovered completely following the removal of catheter and administration of antibiotics, while another did not respond to the treatments. We then treated her with methylprednisolone pulse therapy followed by prednisolone. She responded well, and achieved complete remission. As central venous catheter infection-related glomerulonephritis has a similar etiology to shunt nephritis, removal of the catheter and administration of antibiotics is fundamental to the treatment. If a patient is resistant to such conventional therapy, additional steroid and/or immunosuppressive agent

  3. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    PubMed

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  4. Dried Blood Spot Analysis Suitable for Therapeutic Drug Monitoring of Voriconazole, Fluconazole, and Posaconazole

    PubMed Central

    van der Elst, Kim C. M.; Span, Lambert F. R.; van Hateren, Kai; Vermeulen, Karin M.; van der Werf, Tjip S.; Greijdanus, Ben; Kosterink, Jos G. W.; Uges, Donald R. A.

    2013-01-01

    Invasive aspergillosis and candidemia are important causes of morbidity and mortality in immunocompromised and critically ill patients. The triazoles voriconazole, fluconazole, and posaconazole are widely used for the treatment and prophylaxis of these fungal infections. Due to the variability of the pharmacokinetics of the triazoles among and within individual patients, therapeutic drug monitoring is important for optimizing the efficacy and safety of antifungal treatment. A dried blood spot (DBS) analysis was developed and was clinically validated for voriconazole, fluconazole, and posaconazole in 28 patients. Furthermore, a questionnaire was administered to evaluate the patients' opinions of the sampling method. The DBS analytical method showed linearity over the concentration range measured for all triazoles. Results for accuracy and precision were within accepted ranges; samples were stable at room temperature for at least 12 days; and different hematocrit values and blood spot volumes had no significant influence. The ratio of the drug concentration in DBS samples to that in plasma was 1.0 for voriconazole and fluconazole and 0.9 for posaconazole. Sixty percent of the patients preferred DBS analysis as a sampling method; 15% preferred venous blood sampling; and 25% had no preferred method. There was significantly less perception of pain with the DBS sampling method (P = 0.021). In conclusion, DBS analysis is a reliable alternative to venous blood sampling and can be used for therapeutic drug monitoring of voriconazole, fluconazole, and posaconazole. Patients were satisfied with DBS sampling and had less pain than with venous sampling. Most patients preferred DBS sampling to venous blood sampling. PMID:23896473

  5. NHEXAS PHASE I ARIZONA STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 165 blood samples over 165 households. Each sample was collected as a venous sample from the primary respondent within each household during Stage III of the NHEXAS study. The samples...

  6. NHEXAS PHASE I MARYLAND STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 374 blood samples over 80 households. Each sample was collected via a venous sample from the primary respondent within each household by a phlebotomist. Samples were generally drawn o...

  7. Sickle cell disease and venous thromboembolism in pregnancy and the puerperium.

    PubMed

    Noubouossie, Denis; Key, Nigel S

    2015-02-01

    Recent data strongly suggest an increased risk of venous thromboembolism in subjects with sickle cell disease and to a lesser extent, sickle cell trait. However, most studies have been retrospective, case-control or cross-sectional based on data obtained from administrative databases. More data from adequately powered prospective studies that include matched controls are needed to definitely establish the link between venous thromboembolism during pregnancy and sickle hemoglobin disorders. Similarly, there remains a need for properly designed randomized control trials to establish the safety of various hormonal contraceptive methods in women with sickle cell disorders. © 2015 Elsevier Ltd. All rights reserved.

  8. Blood flow and oxygen uptake during exercise

    NASA Technical Reports Server (NTRS)

    Mitchell, J. W.; Stolwijk, J. A. J.; Nadel, E. R.

    1973-01-01

    A model is developed for predicting oxygen uptake, muscle blood flow, and blood chemistry changes under exercise conditions. In this model, the working muscle mass system is analyzed. The conservation of matter principle is applied to the oxygen in a unit mass of working muscle under transient exercise conditions. This principle is used to relate the inflow of oxygen carried with the blood to the outflow carried with blood, the rate of change of oxygen stored in the muscle myoglobin, and the uptake by the muscle. Standard blood chemistry relations are incorporated to evaluate venous levels of oxygen, pH, and carbon dioxide.

  9. Extracorporeal gas exchange with the DeltaStream rotary blood pump in experimental lung injury.

    PubMed

    Dembinski, Rolf; Kopp, Rüdger; Henzler, Dietrich; Hochhausen, Nadine; Oslender, Nicole; Max, Martin; Rossaint, Rolf; Kuhlen, Ralf

    2003-06-01

    In most severe cases of the acute respiratory distress syndrome, veno-venous extracorporeal membrane oxygenation (ECMO) can be used to facilitate gas exchange. However, the clinical use is limited due to the size and the concomitant risk of severe adverse events of conventionally-used centrifugal blood pumps with high extracorporeal blood volumes. The DeltaStream blood pump is a small-sized rotary blood pump that may reduce extracorporeal blood volume, foreign surfaces, contact activation of the coagulation system, and blood trauma. The aim of the present study was to test the safety and efficacy of the DeltaStream pump for ECMO in animals with normal lung function and experimental acute lung injury (ALI). Therefore, veno-venous ECMO was performed for 6 hours in mechanically ventilated pigs with normal lung function (n=6) and with ALI induced by repeated lung lavage (n=6) with a blood flow of 30% of the cardiac output. Gas flow with a FiO2 of 1.0 was set to equal blood flow. With a mean activated clotting time of 121 +/- 22 s, no circulatory impairment or thrombus formation was revealed during ECMO. Furthermore, free plasma Hb did not increase. In controls, hemodynamics and gas exchange remained unchanged. In animals with ALI, hemodynamics remained stable and gas transfer across the extracorporeal oxygenators was optimal, but only in 2 animals was a marked increase in PaO2 observed. CO2 removal was efficacious in all animals. We concluded that the DeltaStream blood pump may be used for veno-venous ECMO without major blood damage or hemodynamic impairment.

  10. Longitudinal Volume Quantification of Deep Medullary Veins in Patients with Cerebral Venous Sinus Thrombosis : Venous Volume Assessment in Cerebral Venous Sinus Thrombosis Using SWI.

    PubMed

    Dempfle, A K; Harloff, A; Schuchardt, F; Bäuerle, J; Yang, S; Urbach, H; Egger, K

    2017-06-06

    Susceptibility-weighted imaging (SWI) visualizes small cerebral veins with high sensitivity and could, thus, enable quantification of hemodynamics of deep medullary veins. We aimed to evaluate volume changes of deep medullary veins in patients with acute cerebral venous sinus thrombosis (CVST) over time in comparison to healthy controls. All magnetic resonance imaging (MRI) experiments were executed at 3 T using a 32-channel head coil. Based on SWI and semiautomatic postprocessing (statistical parametric mapping [SPM8] and ANTs), the volume of deep medullary veins was quantified in 14 patients with acute CVST at baseline and the 6‑month follow-up, as well as in 13 healthy controls undergoing repeated MRI examination with an interscan interval of at least 1 month. Deep medullary venous volume change over time was significantly different between healthy controls and patient groups (p < 0.001). Patients with superior sagittal sinus thrombosis (SSST) showed a significant decline from baseline to follow-up measurements (9.8 ± 4.9 ml versus 7.5 ± 4.2 ml; p = 0.02), whereas in patients with transverse sinus thrombosis (TST) and healthy controls no significant volume changes were observable. Venous volume quantification was feasible and reproducible both in healthy volunteers and in patients. The decrease of venous volume in patients over time represents improvement of venous drainage, reduction of congestion, and normalization of microcirculation due to treatment. Thus, quantification of venous microcirculation could be valuable for estimation of prognosis and guidance of CVST therapy in the future.

  11. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    PubMed

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P < 0.001) and capillary blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  12. Complex outflow anatomy in left lateral lobe graft and modified venous reconstruction in pediatric living donor liver transplantation.

    PubMed

    Benetatos, Nikolaos; Scalera, Irene; Isaac, John R; Mirza, Darius F; Muiesan, Paolo

    2014-10-01

    Hepatic venous outflow reconstruction is of critical significance in pediatric patients undergoing living donor liver transplantation. Accurate knowledge of the anatomical variations is important to obtain appropriate size segmental grafts. The diameter of the hepatic veins and the potential risk of complications at the level of the anastomosis require an adequate primary vascular reconstruction. We describe a venous outflow reconstruction technique, in a living related left lateral lobe graft, with unfavorable hepatic venous anatomy. © 2014 Steunstichting ESOT.

  13. Direct recording of cardiac output- and venous return-curves in the dog heart-lung preparation for a graphical analysis of the effects of cardioactive drugs.

    PubMed

    Ishikawa, N; Taki, K; Hojo, Y; Hagino, Y; Shigei, T

    1978-09-01

    The dog heart-lung preparations were prepared. The "equilibrium point", which could be defined as the point at which the cardiac output (CO)-curve and the venous return (VR)-curve crossed, when the CO and VR were plotted against the right atrial pressure, was recorded directly by utilizing an X-Y recorder. The CO-curve was obtained, as a locus of the equilibrium point, by raising and lowering the level of blood in the venous reservoir (competence test). The meaning of the procedure was shown to increase or decrease the mean systemic pressure, and to cause the corresponding parallel shift in the VR-curve. The VR-curve was obtained by changing myocardial contractility. When heart failure was induced by pentobarbital or by chloroform, the equilibrium point shifted downwards to the right, depicting the VR-curve. During development of the failure, the slopes of CO-curves decreased gradually. Effects of cinobufagin and norepinephrine were also analyzed. Utilization of the X-Y recorder enabled us to settle the uniform experimental conditions more easily, and to follow the effects of drugs continuously on a diagram equating the CO- and VR-curves (Gyton's scheme).

  14. Intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage in heterotaxy syndrome.

    PubMed

    Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz

    2010-08-01

    A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.

  15. Accuracy of capillary blood 3-β-hydroxybutyrate determination for the detection and treatment of canine diabetic ketoacidosis.

    PubMed

    Bresciani, Francesca; Pietra, Marco; Corradini, Sara; Giunti, Massimo; Fracassi, Federico

    2014-01-01

    In human medicine, diagnosis of diabetic ketoacidosis (DKA) is usually based on measurement of capillary 3-β-hydroxybutyrate (3-HB) with a hand held ketone sensor. This study was conducted to determine if measurement of capillary 3-HB could be useful for the diagnosis and monitoring of canine DKA. Fifteen dogs with diabetic ketosis and 10 with DKA were evaluated. Paired measurements of 3-HB of capillary and venous blood samples were analysed by the electrochemical sensor and reference method. Use of capillary 3-HB measurement during DKA management was then evaluated through simultaneous measurements of capillary 3-HB, urinary AcAc and venous blood gas analysis. Good agreement between capillary and venous 3-HB measurement was detected by the electrochemical sensor and reference method. Monitoring treatment of DKA revealed a significant correlation between capillary 3-HB and acidosis markers, while no significant correlation was observed between AcAc and acidosis markers. A cut-off value of capillary blood 3-HB > 3.8 mmol/L for diagnosis of DKA resulted in 70% and 92% sensitivity and specificity. The electrochemical sensor accurately measures 3-HB concentration in both capillary and venous blood samples, is accurate in diagnosing canine DKA, and appears to reflect the patient's metabolic status during DKA treatment.

  16. A failure of preoperative duplex imaging to diagnose a lower extremity venous aneurysm in a patient with severe chronic venous insufficiency.

    PubMed

    Jones, Roy Wesley; Parkerson, Godfrey Ross; Ottinger, Mary; Rodriguez, Eduardo; Park, Brian

    2017-01-01

    We present a case of recurrent bilateral lower extremity venous stasis ulcers in association with a superficial venous aneurysm at the right saphenofemoral junction that was misdiagnosed on preoperative duplex scanning. A 53-year-old female presented to our clinic with 6-year history of bilateral lower extremity venous stasis ulcers. Her past medical history was significant for refractory venous stasis ulcers of the bilateral lower extremities present for 6 years and morbid obesity. Preoperative venous duplex demonstrated severe venous insufficiency of the superficial and deep systems, but a venous aneurysm was not appreciated. During the high ligation of the right saphenofemoral junction, a 3 × 4 × 5 cm aneurysm was encountered. Repair consisted of aneurysm resection, high ligation of the greater saphenous vein, dissociation of the great saphenous and anterior saphenous veins, and stab phlebectomy of large varicose veins of the thigh and lower leg. The patient recovered uneventfully and experienced complete healing of the venous stasis ulcer in several weeks. Superficial venous aneurysms of the lower extremity are rare and can be often missed on preoperative duplex ultrasound imaging. Large diameter measurements of the proximal greater saphenous vein and obesity increase the risk of misdiagnosing venous aneurysms with duplex imaging; therefore, clinical suspicion must remain high. These aneurysms can be associated with significant symptoms for which repair is indicated.

  17. Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

    PubMed

    Olateju, Tolu; Begley, Joseph; Flanagan, Daniel; Kerr, David

    2012-07-01

    Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydrogenase (GDH)-based meters at high altitude. The aim of our study was to evaluate the performance of four new-generation BGMs at sea level and at a simulated altitude equivalent to that used in the cabin of commercial aircrafts. Blood glucose measurements obtained by two GDH and two GOX BGMs at sea level and simulated altitude of 8000 feet in a hypobaric chamber were compared with measurements obtained using a YSI 2300 blood glucose analyzer as a reference method. Spiked venous blood samples of three different glucose levels were used. The accuracy of each meter was determined by calculating percentage error of each meter compared with the YSI reference and was also assessed against standard International Organization for Standardization (ISO) criteria. Clinical accuracy was evaluated using the consensus error grid method. The percentage (standard deviation) error for GDH meters at sea level and altitude was 13.36% (8.83%; for meter 1) and 12.97% (8.03%; for meter 2) with p = .784, and for GOX meters was 5.88% (7.35%; for meter 3) and 7.38% (6.20%; for meter 4) with p = .187. There was variation in the number of time individual meters met the standard ISO criteria ranging from 72-100%. Results from all four meters at both sea level and simulated altitude fell within zones A and B of the consensus error grid, using YSI as the reference. Overall, at simulated altitude, no differences were observed between the performance of GDH and GOX meters. Overestimation of blood glucose concentration was seen among individual meters evaluated, but none of the results obtained would have resulted in

  18. Use of microcirculatory parameters to evaluate clinical treatments of chronic venous disorder (CVD).

    PubMed

    Lascasas-Porto, Carmen Lucia; Milhomens, Ana Letícia M; Virgini-Magalhães, Carlos Eduardo; Fernandes, Fabiano F A; Sicuro, Fernando L; Bouskela, Eliete

    2008-05-01

    To evaluate changes on cutaneous microangiopathy in chronic venous disorder (CVD) after use of Cirkan [venotonic drug containing Ruscus aculeatus (plant extract), hesperidine methylchalcone (flavonoid) and vitamin C], elastic compression stockings (ECS) or no treatment for four weeks. Fifty-five female patients (85 legs), 25 to 57 years, with at least one limb classified as C2,s or C2,3,s (CEAP classification), were allocated consecutively, according to entrance order, in these three groups. Ten healthy women age-matched were also investigated. Using orthogonal polarization spectral technique (noninvasive method), measurements of functional capillary density (FCD, number of capillaries with flowing red blood cells/mm(2)), capillary morphology (CM, % of abnormal capillaries/mm(2)) and diameters (mum) of dermal papilla (DDP), capillary bulk (DCB) and capillary limb (CD) were obtained on the medial perimalleolar region and later analyzed using CapImage software. CVD patients showed significant changes on CD and CM compared to healthy subjects in agreement with our previous findings (J Vasc Surg 43:1037-1044, 2006). On Cirkan-treated patients, after 4 weeks, CD decreased on both limbs and CM improved on the left one, suggesting an amelioration of the chronic venous hypertension. No significant changes could be detected on other patient groups. These results confirm the existence of microcirculatory dysfunction in early stages of CVD, probably due to post-capillary hypertension, and further support the venotonic action of Cirkan.

  19. Influence of radiographic contrast media (Iodixanol and Iomeprol) on the endothelin-1 release from human arterial and venous endothelial cells cultured on an extracellular matrix.

    PubMed

    Franke, R P; Fuhrmann, R; Hiebl, B; Jung, F

    2012-01-01

    Various radiographic contrast media (RCM) are available for visualization of blood vessels in interventional cardiology which can vary widely in their physicochemical properties thereby influencing different functions of blood cells. In the in vitro study described here the influence of two RCMs on arterial as well as on venous endothelial cells was compared to control cultures and examined under statical culture conditions, thus eliminating the influence of RCM viscosity almost completely. The supplementation of the culture medium with RCM (30% v/v) resulted in clearly different reactions of the endothelial cells exposed. Exposition to Iodixanol supplemented culture medium was followed by endothelin-1 release from venous endothelial cells which was equivalent to the endothelin-1 release from venous control cultures. Compared to control cultures, venous endothelial cells exposed to culture medium supplemented with Iomeprol displayed a completely different reaction, the increase in endothelin-1 secretion was missing completely after a 12 hours exposure. Following a 12 hours exposure to both RCMs there were no longer endothelial cells adherent, neither in venous nor in arterial endothelial cell cultures. The study showed that not the wall shear stress was responsible for the differing effects visible after 1.5 min, 5 min, and 12 hours exposure to culture media supplemented with RCM but differences in chemotoxicity of the RCM applied.

  20. Deep Vein Thrombosis (DVT) / Pulmonary Embolism (PE) - Blood Clot Forming in a Vein

    MedlinePlus

    ... Controls Cancel Submit Search the CDC Venous Thromboembolism (Blood Clots) Note: Javascript is disabled or is not supported ... Challenge HA-VTE Data & Statistics HA-VTE Resources Blood Clots and Travel Research and Treatment Centers Data & Statistics ...

  1. Cerebral blood flow in patients with congestive heart failure treated with captopril.

    PubMed

    Paulson, O B; Jarden, J O; Godtfredsen, J; Vorstrup, S

    1984-05-31

    The effect of captopril on cerebral blood flow was studied in five patients with severe congestive heart failure and in five control subjects. Cerebral blood flow was measured by inhalation of 133xenon and registration of its uptake and washout from the brain by single photon emission computer tomography. In addition, cerebral (internal jugular) venous oxygen tension was determined in the controls. The measurements were made before and 15, 60, and 180 minutes after a single oral dose of captopril (6.25 mg in patients with congestive heart failure and 25 mg in controls). Despite a marked decrease in blood pressure, cerebral blood flow increased slightly in the patients with severe congestive heart failure. When a correction was applied to take account of a change in arterial carbon dioxide tension, however, cerebral blood flow was unchanged after captopril administration even in patients with the greatest decrease in blood pressure, in whom a decrease in cerebral blood flow might have been expected. In the controls, blood pressure was little affected by captopril, whereas a slight, but not statistically significant, decrease in cerebral blood flow was observed. The cerebral venous oxygen tension decreased concomitantly.

  2. Anomalous pulmonary venous connection: An underestimated entity.

    PubMed

    Magalhães, Sara P; Moreno, Nuno; Loureiro, Marília; França, Manuela; Reis, Fernanda; Alvares, Sílvia; Ribeiro, Manuel

    2016-12-01

    Anomalous pulmonary venous connection is an uncommon congenital anomaly in which all (total form) or some (partial form) pulmonary veins drain into a systemic vein or into the right atrium rather than into the left atrium. The authors present one case of total anomalous pulmonary venous connection and two cases of partial anomalous pulmonary venous connection, one of supracardiac drainage into the brachiocephalic vein, and the other of infracardiac anomalous venous drainage (scimitar syndrome). Through the presentation of these cases, this article aims to review the main pulmonary venous developmental defects, highlighting the role of imaging techniques in the assessment of these anomalies. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Management of end-stage central venous access in children referred for possible small bowel transplantation.

    PubMed

    Rodrigues, A F; van Mourik, I D M; Sharif, K; Barron, D J; de Giovanni, J V; Bennett, J; Bromley, P; Protheroe, S; John, P; de Ville de Goyet, J; Beath, S V

    2006-04-01

    liver and SBTx nearly 3 years after presenting with end-stage central venous access, because attempts to achieve independence from parenteral nutrition had failed. The other child died immediately after a transhepatic venous catheter placement, possibly from a nutritional depletion syndrome as no physical cause of death was found. Direct intra-atrial catheters in transplanted children proved to be adequate for the management of uncomplicated transplantation, although the usual infusion protocol had to be modified considerably, and the lack of access would have been critical if massive blood transfusion had been required during the transplant procedure. It was possible to reestablish central venous access in all cases. However, this was time consuming and difficult to assemble a skilled team consisting of one of more: surgeon, cardiologist, interventional radiologist, and transplant anesthetist. Small bowel transplantation is easier and safer with adequate central venous access, and we advocate liaison with an SBTx center at an early stage.

  4. Venous thromboembolism: a UK perspective.

    PubMed

    Kakkar, Ajay

    2009-07-01

    Venous thromboembolism remains a significant cause of morbidity and mortality in the UK, and its dangers, particularly in hospitalized patients, have long been recognized. Recent measures to tackle this problem and new treatments should alleviate the burden of venous thromboembolism for patients, their families and hospital services.

  5. Are central venous catheter tip cultures reliable after 6-day refrigeration?

    PubMed

    Bouza, Emilio; Guembe, Maria; Gómez, Haydee; Martín-Rabadán, Pablo; Rivera, Marisa; Alcalá, Luis

    2009-07-01

    Present guidelines recommend culturing only central venous catheter (CVC) tips from patients with suspected catheter-related bloodstream infection (CR-BSI). However, a high proportion of these suspicions are not confirmed. Moreover, CVC tip culture increases laboratory workload, and reports of colonization may be meaningless or misleading for the clinician. Our working hypothesis was that CVC tips should be refrigerated and cultured only in patients with positive blood cultures. We evaluated the effect of 6-day refrigeration of 215 CVC tips. We selected all the catheters with a significant count according to the Maki's roll-plate technique and randomly assigned them to 2 groups. In group A, the catheters were recultured after 24 h of refrigeration, and in group B, the catheters were recultured after 6 days more of refrigeration, so that the refrigeration time evaluated would be of 6 days. The yield of refrigerated CVC tips that grow significant colony counts of primary culture in group B was compared with the yield of refrigerated catheter tips in group A. The difference showed that 6-day refrigeration reduced the number of significant CVCs by 15.2%. Only 61 CVCs were obtained from patients with CR-BSI, and in most of them, blood cultures were already positive before CVC culture, so only 0.91% of the CR-BSI episodes would have been misdiagnosed as culture negative after refrigeration. Refrigeration of CVC tips sent for culture and culturing only those from patients with positive blood cultures reduce the workload in the microbiology laboratory without misdiagnosing CR-BSI.

  6. Automatic Control of Veno-Venous Extracorporeal Lung Assist.

    PubMed

    Kopp, Ruedger; Bensberg, Ralf; Stollenwerk, Andre; Arens, Jutta; Grottke, Oliver; Walter, Marian; Rossaint, Rolf

    2016-10-01

    Veno-venous extracorporeal lung assist (ECLA) can provide sufficient gas exchange even in most severe cases of acute respiratory distress syndrome. Commercially available systems are manually controlled, although an automatically controlled ECLA could allow individualized and continuous adaption to clinical requirements. Therefore, we developed a demonstrator with an integrated control algorithm to keep continuously measured peripheral oxygen saturation and partial pressure of carbon dioxide constant by automatically adjusting extracorporeal blood and gas flow. The "SmartECLA" system was tested in six animal experiments with increasing pulmonary hypoventilation and hypoxic inspiratory gas mixture to simulate progressive acute respiratory failure. During a cumulative evaluation time of 32 h for all experiments, automatic ECLA control resulted in a peripheral oxygen saturation ≥90% for 98% of the time with the lowest value of 82% for 15 s. Partial pressure of venous carbon dioxide was between 40 and 49 mm Hg for 97% of the time with no value <35 mm Hg or >49 mm Hg. With decreasing inspiratory oxygen concentration, extracorporeal oxygen uptake increased from 68 ± 25 to 154 ± 34 mL/min (P < 0.05), and reducing respiratory rate resulted in increasing extracorporeal carbon dioxide elimination from 71 ± 37 to 92 ± 37 mL/min (P < 0.05). The "SmartECLA" demonstrator allowed reliable automatic control of the extracorporeal circuit. Proof of concept could be demonstrated for this novel automatically controlled veno-venous ECLA circuit. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Risk factors for upper extremity venous thrombosis associated with peripherally inserted central venous catheters.

    PubMed

    Marnejon, Thomas; Angelo, Debra; Abu Abdou, Ahmed; Gemmel, David

    2012-01-01

    To identify clinically important risk factors associated with upper extremity venous thrombosis following peripherally inserted central venous catheters (PICC). A retrospective case control study of 400 consecutive patients with and without upper extremity venous thrombosis post-PICC insertion was performed. Patient data included demographics, body mass index (BMI), ethnicity, site of insertion, size and lumen of catheter, internal length, infusate, and co-morbidities, such as diabetes mellitus, congestive heart failure, and renal failure. Additional risk factors analyzed were active cancer, any history of cancer, recent trauma, smoking, a history of prior deep vein thrombosis, and recent surgery, defined as surgery within three months prior to PICC insertion. The prevalence of trauma, renal failure, and infusion with antibiotics and total parenteral nutrition (TPN) was higher among patients exhibiting upper extremity venous thrombosis (UEVT), when compared to controls. Patients developing UEVT were also more likely to have PICC line placement in a basilic vein and less likely to have brachial vein placement (P<.001). Left-sided PICC line sites also posed a greater risk (P=.026). The rate of standard DVT prophylaxis with low molecular weight heparin and unfractionated heparin and the use of warfarin was similar in both groups. Average length of hospital stay was almost double among patients developing UEVT, 19.5 days, when compared to patients undergoing PICC line insertion without thrombosis, 10.8 days (t=6.98, P<.001). In multivariate analysis, trauma, renal failure, left-sided catheters, basilic placement, TPN, and infusion with antibiotics, specifically vancomycin, were significant risk factors for UEVT associated with PICC insertion. Prophylaxis with low molecular weight heparin, unfractionated heparin or use of warfarin did not prevent the development of venous thrombosis in patients with PICCs. Length of hospital stay and cost are markedly increased in

  8. Venous trauma in the Lebanon War--2006.

    PubMed

    Nitecki, Samy S; Karram, Tony; Hoffman, Aaron; Bass, Arie

    2007-10-01

    Reports on venous trauma are relatively sparse. Severe venous trauma is manifested by hemorrhage, not ischemia. Bleeding may be internal or external and rarely may lead to hypovolemic shock. Repair of major extremity veins has been a subject of controversy and the current teaching is to avoid venous repair in an unstable or multi-trauma patient. The aim of the current paper is to present our recent experience in major venous trauma during the Lebanon conflict, means of diagnosis and treatment in a level I trauma center. All cases of major venous trauma, either isolated or combined with arterial injury, admitted to the emergency room during the 33-day conflict were reviewed. Out of 511 wounded soldiers and civilians who were admitted to our service over this period, 12 (2.3%) sustained a penetrating venous injury either isolated (5) or combined with arterial injury (7). All injuries were secondary to high velocity penetrating missiles or from multiple pellets stored in long-range missiles. All injuries were accompanied by additional insult to soft tissue, bone and viscera. The mean injury severity score was 15. Severe external bleeding was the presenting symptom in three cases of isolated venous injury (jugular, popliteal and femoral). The diagnosis of a major venous injury was made by a CTA scan in five cases, angiography in one and during surgical exploration in six cases. All injured veins were repaired: three by venous interposition grafts, four by end to end anastomosis, three by lateral suture and two by endovascular techniques. None of the injuries was treated by ligation of a major named vein. Immediate postoperative course was uneventful in all patients and the 30-day follow-up (by clinical assessment and duplex scan) has demonstrated a patent repair with no evidence of thrombosis. Without contradicting the wisdom of ligating major veins in the setup of multi-trauma or an unstable patient, our experience indicates that a routine repair of venous trauma can

  9. The use of micro-/milli-fluidics to better understand the mechanisms behind deep venous thrombosis

    NASA Astrophysics Data System (ADS)

    Schofield, Zoe; Alexiadis, Alessio; Brill, Alexander; Nash, Gerard; Vigolo, Daniele

    2016-11-01

    Deep venous thrombosis (DVT) is a dangerous and painful condition in which blood clots form in deep veins (e.g., femoral vein). If these clots become unstable and detach from the thrombus they can be delivered to the lungs resulting in a life threatening complication called pulmonary embolism (PE). Mechanisms of clot development in veins remain unclear but researchers suspect that the specific flow patterns in veins, especially around the valve flaps, play a fundamental role. Here we show how it is now possible to mimic the current murine model by developing micro-/milli-fluidic experiments. We exploited a novel detection technique, ghost particle velocimetry (GPV), to analyse the velocity profiles for various geometries. These vary from regular microfluidics with a rectangular cross section with a range of geometries (mimicking the presence of side and back branches in veins, closed side branch and flexible valves) to a more accurate venous representation with a 3D cylindrical geometry obtained by 3D printing. In addition to the GPV experiments, we analysed the flow field developing in these geometries by using computational fluid dynamic simulations to develop a better understanding of the mechanisms behind DVT. ZS gratefully acknowledges financial support from the EPSRC through a studentship from the Sci-Phy-4-Health Centre for Doctoral Training (EP/L016346/1).

  10. An analysis of leukapheresis and central venous catheter use in the randomized, placebo controlled, phase 3 IMPACT trial of Sipuleucel-T for metastatic castrate resistant prostate cancer.

    PubMed

    Flanigan, Robert C; Polcari, Anthony J; Shore, Neil D; Price, Thomas H; Sims, Robert B; Maher, Johnathan C; Whitmore, James B; Corman, John M

    2013-02-01

    Sipuleucel-T is an autologous cellular immunotherapy. We review the safety of the leukapheresis procedure required for sipuleucel-T preparation and complications related to venous catheter use in the randomized, placebo controlled phase 3 IMPACT (IMmunotherapy for ProstAte Cancer Trial) study (NCT 00065442). A total of 512 patients with asymptomatic or minimally symptomatic metastatic castrate resistant prostate cancer were enrolled in the study. All patients were scheduled to undergo 3 standard 1.5 to 2.0 blood volume leukapheresis procedures at 2-week intervals. Leukapheresis related adverse events and those related to venous catheter use were reviewed. Immune cell counts were examined throughout the treatment course. Of 512 enrolled patients 506 underwent 1 or more leukapheresis procedures and were included in this analysis. Adverse events were comparable between the sipuleucel-T and control arms. Leukapheresis related adverse events were primarily associated with transient hypocalcemia (39.3%). Most leukapheresis related adverse events (97%) were of mild/moderate intensity. Median white blood cell count and absolute monocyte and lymphocyte counts were stable and within normal ranges throughout the treatment course. Of all patients 23.3% had a central venous catheter placed primarily for leukapheresis. Patients with vs without a central venous catheter had a higher risk of infection potentially related to catheter use (11.9% vs 1.3%, p <0.0001) and a trend toward a higher incidence of venous vascular events potentially related to catheter use, excluding the central nervous system (5.9% vs 2.1%, p = 0.06). Adverse events related to leukapheresis are manageable and quickly reversible. The majority of patients can undergo leukapheresis without a central venous catheter. Central venous catheters are associated with an increased risk of infections and venous vascular events. Peripheral intravenous access should be used when feasible. Copyright © 2013 American

  11. Percutaneous transfemoral repositioning of malpositioned central venous catheters.

    PubMed

    Hartnell, G G; Roizental, M

    1995-04-01

    Central venous catheters inserted by blind surgical placement may not advance into a satisfactory position and may require repositioning. Malpositioning via surgical insertion is common in patients in whom central venous catheters have previously been placed, as these patients are more likely to have central venous thrombosis and distortion of central venous anatomy. This is less of a problem when catheter placement is guided by imaging; however, even when insertion is satisfactory, central venous catheters may become displaced spontaneously after insertion (Fig. 1). Repositioning can be effected by direct manipulation using guidewires or tip-deflecting wires [1, 2], by manipulation via a transfemoral venous approach [3-5], and by injection of contrast material or saline [6]. Limitations of the direct approach include (1) the number and type of maneuvers that can be performed to effect repositioning when anatomy is distorted, (2) difficulty in accessing the catheter, and (3) the risk of introducing infection. Moreover, these patients are often immunosuppressed, and there is a risk of introducing infection by exposing and directly manipulating the venous catheter. Vigorous injection of contrast material or saline may be unsuccessful for the same reasons: It seldom exerts sufficient force to reposition large-caliber central venous catheters and may cause vessel damage or rupture if injection is made into a small or thrombosed vessel. We illustrate several alternative methods for catheter repositioning via a transfemoral venous approach.

  12. Surgical management of venous malformations.

    PubMed

    Loose, D A

    2007-01-01

    Among vascular malformations, the predominantly venous malformations represent the majority of cases. They form a clinical entity and therefore need clear concepts concerning diagnosis and treatment. This paper presents an overview of contemporary classification as well as tactics and techniques of treatment. According to the Hamburg Classification, predominantly venous malformations are categorized into truncular and extratruncular forms, with truncular forms distinguished as obstructions and dilations, and extratruncular forms as limited or infiltrating. The tactics of treatment represent surgical and non-surgical methods or combined techniques. Surgical approaches utilize different tactics and techniques that are adopted based on the pathologic form and type of the malformation: (I) operation to reduce the haemodynamic activity of the malformation; (II) operation to eliminate the malformation; and (III) reconstructive operation. As for (I), a type of a tactic is the operation to derive the venous flow. In (II), the total or partial removal of the venous malformation is demonstrated subdivided into three different techniques. In this way, the infiltrating as well as the limited forms can be treated. An additional technique is dedicated to the treatment of a marginal vein. Approach (III) involves the treatment of venous aneurysms, where a variety of techniques have been successful. Long-term follow-up demonstrates positive results in 91% of the cases. Congenital predominantly venous malformations should be treated according to the principles developed during the past decades in vascular surgery, interventional treatment and multidisciplinary treatment. The days of predominantly conservative treatment should be relegated to the past. Special skills and experiences are necessary to carry out appropriate surgical strategy, and the required operative techniques should be dictated by the location and type of malformation and associated findings.

  13. Dielectric coagulometry: a new approach to estimate venous thrombosis risk.

    PubMed

    Hayashi, Yoshihito; Katsumoto, Yoichi; Omori, Shinji; Yasuda, Akio; Asami, Koji; Kaibara, Makoto; Uchimura, Isao

    2010-12-01

    We present dielectric coagulometry as a new technique to estimate the risk of venous thrombosis by measuring the permittivity change associated with the blood coagulation process. The method was first tested for a simple system of animal erythrocytes suspended in fibrinogen solution, where the coagulation rate was controlled by changing the amount of thrombin added to the suspension. Second, the method was applied to a more realistic system of human whole blood, and the inherent coagulation process was monitored without artificial acceleration by a coagulation initiator. The time dependence of the permittivity at a frequency around 1 MHz showed a distinct peak at a time that corresponds to the clotting time. Our theoretical modeling revealed that the evolution of heterogeneity and the sedimentation in the system cause the peak of the permittivity.

  14. Mixed-venous oxygen tension by nitrogen rebreathing - A critical, theoretical analysis.

    NASA Technical Reports Server (NTRS)

    Kelman, G. R.

    1972-01-01

    There is dispute about the validity of the nitrogen rebreathing technique for determination of mixed-venous oxygen tension. This theoretical analysis examines the circumstances under which the technique is likely to be applicable. When the plateau method is used the probable error in mixed-venous oxygen tension is plus or minus 2.5 mm Hg at rest, and of the order of plus or minus 1 mm Hg during exercise. Provided, that the rebreathing bag size is reasonably chosen, Denison's (1967) extrapolation technique gives results at least as accurate as those obtained by the plateau method. At rest, however, extrapolation should be to 30 rather than to 20 sec.

  15. The expression of inflammatory cytokines, TAM tyrosine kinase receptors and their ligands is upregulated in venous leg ulcer patients: a novel insight into chronic wound immunity.

    PubMed

    Filkor, Kata; Németh, Tibor; Nagy, István; Kondorosi, Éva; Urbán, Edit; Kemény, Lajos; Szolnoky, Győző

    2016-08-01

    The systemic host defence mechanisms, especially innate immunity, in venous leg ulcer patients are poorly investigated. The aim of the current study was to measure Candida albicans killing activity and gene expressions of pro- and anti-inflammatory cytokines and innate immune response regulators, TAM receptors and ligands of peripheral blood mononuclear cells separated from 69 venous leg ulcer patients and 42 control probands. Leg ulcer patients were stratified into responder and non-responder groups on the basis of wound healing properties. No statistical differences were found in Candida killing among controls, responders and non-responders. Circulating blood mononuclear cells of patients overexpress pro-inflammatory (IL-1α, TNFα, CXCL-8) and anti-inflammatory (IL-10) cytokines as well as TAM receptors (Tyro, Axl, MerTK) and their ligands Gas6 and Protein S compared with those of control individuals. IL-1α is notably overexpressed in venous leg ulcer treatment non-responders; in contrast, Axl gene expression is robustly stronger among responders. These markers may be considered as candidates for the prediction of treatment response among venous leg ulcer patients. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  16. Optical methods for correction of oxygen-transport characteristics of blood and their biomedical applications

    NASA Astrophysics Data System (ADS)

    Zalesskaya, G. A.; Akulich, N. V.; Marochkov, A. V.; Laskina, O. V.; Mit'kovskaya, N. P.

    2010-07-01

    We have carried out a comprehensive analysis of the spectral characteristics of blood and blood components, gas-exchange and oximetry parameters for venous and arterial blood, central hemodynamic parameters, and the results of a complete blood count and chemistry panel before and after extracorporeal UV irradiation of the blood (UBI, ultraviolet blood irradiation) or intravenous exposure of blood to low-intensity emission from an He-Ne laser (LBI, laser blood irradiation). We have demonstrated the possibility of correcting the oxygentransport characteristics of blood by laser optical methods based on photodissociation of blood oxyhemoglobin. We have shown that the therapeutic effects initiated both by UBI and LBI are based on a single mechanism: a change in the balance between production of active oxygen species and their inhibition by antioxidants. The data obtained are of interest not only for studying the primary (molecular) mechanisms of action for photohemotherapy and their effect on processes occurring in the living body, but also can provide a basis for designing next-generation laser optical instruments and for development of not yet existing methods for assessing the therapeutic efficacy of photohemotherapy.

  17. [Venous access in oncology].

    PubMed

    Lesimple, T; Béguec, J F; Levêque, J M

    1998-10-31

    Many treatments administered to cancer patients require venous access either via a peripheral vein or a larger central vein at the risk of local or systemic infection, thrombus formation or venous occlusion and dysfunction. Insertion of a central catheter is an invasive procedure which must be conducted under conditions of rigorous asepsia. Strict rules based on well-defined protocols must be applied throughout its use. Local or systemic infectious complications account for 18 to 25% of all nosocomial infections and are often related to colonisation of the puncture site by a Gram positive germ. In case of infection, ablation of the central catheter is not mandatory for diagnosis or antibiotic treatment. Reported at varying frequencies in the literature from 4 to 42%, thrombus formation is unpredictable and often difficult to diagnose. Anticoagulants or fibrolytic agents are indicated but it may also be necessary to withdraw the catheter. Displacement, rupture, obstruction and extravasation are frequent complications. Back flow must be checked in all venous accesses and free flow carefully verified. The access must remain patent throughout the period of use, guaranteed by a standard heparinization and rinsing protocol. This complications must not mask the important progress achieved with the use of central venous access for specific and symptomatic treatment in cancer patients.

  18. Wavelength dependence of the apparent diameter of retinal blood vessels

    NASA Astrophysics Data System (ADS)

    Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David

    2005-04-01

    Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.

  19. Assessment of cerebral venous sinus thrombosis using T2*-weighted gradient echo magnetic resonance imaging sequences

    PubMed Central

    Bidar, Fatemeh; Faeghi, Fariborz; Ghorbani, Askar

    2016-01-01

    Background: The purpose of this study is to demonstrate the advantages of gradient echo (GRE) sequences in the detection and characterization of cerebral venous sinus thrombosis compared to conventional magnetic resonance sequences. Methods: A total of 17 patients with cerebral venous thrombosis (CVT) were evaluated using different magnetic resonance imaging (MRI) sequences. The MRI sequences included T1-weighted spin echo (SE) imaging, T*2-weighted turbo SE (TSE), fluid attenuated inversion recovery (FLAIR), T*2-weighted conventional GRE, and diffusion weighted imaging (DWI). MR venography (MRV) images were obtained as the golden standard. Results: Venous sinus thrombosis was best detectable in T*2-weighted conventional GRE sequences in all patients except in one case. Venous thrombosis was undetectable in DWI. T*2-weighted GRE sequences were superior to T*2-weighted TSE, T1-weighted SE, and FLAIR. Enhanced MRV was successful in displaying the location of thrombosis. Conclusion: T*2-weighted conventional GRE sequences are probably the best method for the assessment of cerebral venous sinus thrombosis. The mentioned method is non-invasive; therefore, it can be employed in the clinical evaluation of cerebral venous sinus thrombosis. PMID:27326365

  20. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    PubMed Central

    Shawaf, Turke; El-Deeb, Wael; Hussen, Jamal; Hendi, Mahmoud; Al-Bulushi, Shahab

    2018-01-01

    Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama) on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml) size with narrow mouths were used. A manual pump (sucking cups) was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusions: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  1. Systemic venous anomalies in the Middle East

    PubMed Central

    Corno, Antonio F.; Alahdal, Sami A.; Das, Karuna Moy

    2013-01-01

    Introduction: Systemic venous anomalies are quite rare and can be associated with congenital heart disease requiring surgery. Materials and Methods: All consecutive patients (pts) undergoing surgery for congenital heart defects were retrospectively analyzed for presence of systemic venous anomalies: (a) Persistent left superior vena cava (PLSVC)(b) Inferior vena cava (IVC) interruption(c) Retro-aortic innominate vein Results: From 9/2010 to 5/2012 155 pts, median age 7 months, mean age 1.3 years (3 days–50 years), median weight 4 kg, mean weight 7.2 kg (0.6–110 kg) underwent congenital heart surgery. Twenty-nine systemic venous anomalies were identified in 28/155 patients (=18.1%). PLSVC was present in 21 pts (=13.5%), median age 4 months, mean age 2.7 years (3 days–22 years), median weight 6 kg, mean weight 10.1 kg (2.4–43.0 kg). IVC interruption was identified in 5 pts (=3.2%), median age 2 months, mean age 5.4 years (30 days–26 years), median weight 3.7 kg, median weight 17 kg (2.3–68.0 kg). Retro-aortic innominate vein was diagnosed in 3 pts (=1.9%), median age 5 years, mean age 3.7 years (10 months–5 years), median weight 12 kg, mean weight 10.1 kg (4.5–14 kg). Complete pre-operative diagnosis was obtained in 14/28 (=50%) pts with echocardiography and in other 8/28 (=28.6%) only after computed tomography (CT) scan, for a total of 22/28 (=78.6%) correct pre-operative diagnosis. In 6/28 (=21.4%) patients the diagnosis was intra-operative. Total incidence of systemic venous anomalies was 18.1% (vs. 4% in the literature, P = 0.0009), with presence of PLSVC = 13.5% (vs. 0.3–4.0%, respectively P = 0.0004 and P = 0.0012), IVC interruption = 3.2% (vs. 0.1–1.3%, N.S.), and retro-aortic innominate vein = 1.9% (vs. 0.2–1%, N.S.). Conclusions: Our study showed an incidence of systemic venous anomalies in Middle Eastern pts with congenital heart defects higher than previously reported. In 78.6% of pts the diagnosis was correctly made before surgery

  2. The use of intermittent and continuous recordings of jugular venous bulb oxygen saturation in the unconscious patient.

    PubMed

    Garlick, R; Bihari, D

    1987-01-01

    Monitoring clinical signs in unconscious patients provides only late information about cerebral deterioration. Ischaemia and hypoxia are the mechanisms of much of the damage. Cerebral blood flow (CBF) measurements provide direct evidence of ischaemia but are intermittent values for what may be an unstable situation. Continuous recordings of CBF and oxygenation are more likely to reveal harmful tendencies to ischaemia and hypoxia at an early stage than intermittent readings. We report our experience with intermittent and also continuous recording of the jugular venous bulb oxygen saturation (JVO2Sat) obtained by fibreoptic oximetry in a group of 10 head injured and 7 septic patients. Simultaneous measurements of CBF by an isotopic xenon clearance method were also made. The JVO2Sat has been suggested to be a reliable indicator of cerebral oxygenation, a low value being indicative of ischaemia. We discuss whether our findings support this statement. There are also variations in JVO2Sat with mean arterial blood pressure and intracranial pressure. These variations have important implications in the interpretation that can be made of one single value of JVO2Sat.

  3. Characterization of central venous catheter-associated deep venous thrombosis in infants.

    PubMed

    Gray, Brian W; Gonzalez, Raquel; Warrier, Kavita S; Stephens, Lauren A; Drongowski, Robert A; Pipe, Steven W; Mychaliska, George B

    2012-06-01

    Deep venous thrombosis (DVT) is a frequent complication in infants with central venous catheters (CVCs). We performed this study to identify risk factors and risk-reduction strategies of CVC-associated DVT in infants. Infants younger than 1 year who had a CVC placed at our center from 2005 to 2009 were reviewed. Patients with ultrasonically diagnosed DVT were compared to those without radiographic evidence. Of 333 patients, 47% (155/333) had femoral, 33% (111/333) had jugular, and 19% (64/333) had subclavian CVCs. Deep venous thromboses occurred in 18% (60/333) of patients. Sixty percent (36/60) of DVTs were in femoral veins. Femoral CVCs were associated with greater DVT rates (27%; 42/155) than jugular (11%; 12/111) or subclavian CVCs (9%; 6/64; P < .01). There was a 16% DVT rate in those with saphenofemoral Broviac CVCs vs 83% (20/24) in those with percutaneous femoral lines (P < .01). Multilumen CVCs had higher DVT rates than did single-lumen CVCs (54% vs 6%, P < .01), and mean catheter days before DVT diagnosis was shorter for percutaneous lines than Broviacs (13 ± 17 days vs 30 ± 37 days, P = .02). Patients with +DVT had longer length of stay (86 ± 88 days vs 48 ± 48 days, P < .01) and higher percentage of intensive care unit admission (82% vs 70%, P = .02). Deep venous thrombosis reduction strategies in infants with CVCs include avoiding percutaneous femoral and multilumen CVCs, screening percutaneous lines, and early catheter removal. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Prospective comparison of two management strategies of central venous catheters in burn patients.

    PubMed

    Kealey, G P; Chang, P; Heinle, J; Rosenquist, M D; Lewis, R W

    1995-03-01

    Central venous catheters (CVCs) are associated with sepsis in burn patients. This study was undertaken to compare two strategies of CVC management in patients with major burn injuries. Forty-two burn patients with major burn injuries were randomly assigned to undergo site change every 48 hours of the CVC or to undergo wire guide exchange of the CVC every 48 hours at the same site. Catheter insertion site, distance from the burn wound, cultures of catheter tips, and blood cultures were obtained from all patients in a prospective manner. There was no difference in the incidence of CVC sepsis between the two groups studied. CVCs inserted less than 5 cm from the burn wound developed bacterial contamination at an earlier time than CVCs inserted more than 5 cm from the burn wound. There was no advantage to changing the CVC insertion site every 48 hours. Changing the CVC using the wire guide technique did not prevent, nor predict, CVC bacterial contamination.

  5. [Superior vena cava syndrome unrelated to central venous catheter in a patient on chronic hemodialysis].

    PubMed

    Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio

    2011-01-01

    A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.

  6. Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.

    PubMed

    Hudacko, Andrea; Sievert, Alicia; Sistino, Joseph

    2009-09-01

    Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller venous line diameter and venous cannulae. This study examines the effects of CPB initiation with an unprimed venous line and VAVD in a pediatric circuit. A CPB circuit was set up with reservoir, oxygenator, and arterial filter with a bag reservoir to simulate the patient. All trials were done in vitro, and GME were measured using the EDAC Quantifier by Luna Innovations. EDAC sensors were placed proximal and distal to the oxygenator and distal to the arterial filter. Group 1 was the control group with no VAVD and a primed venous line. Groups 2, 3, and 4 used an unprimed venous line and VAVD of -40, -20, and -10 mmHg, respectively. Total microemboli counts and total embolic load in micrometers were measured at each sensor. Groups 2 (12,379.00 +/- 3180.37) and 3 (8296.67 +/- 2818.76) had significantly more microemboli than group 1 (923.33 +/- 796.08, p < .05) at the pre-oxygenator sensor. Group 2 (57.33 +/- 25.01, p < .05) had significantly more microemboli than group 1 (5.33 +/- 3.21) at the post-oxygenator sensor. No other findings were statistically significant. The results suggest that, if an oxygenator and arterial filter with sufficient air handling capabilities are used, this method to reduce prime volume may not increase GME in the arterial line distal to the arterial filter.

  7. Effect of hepatic venous sphincter contraction on transmission of central venous pressure to lobar and portal pressure.

    PubMed

    Lautt, W W; Legare, D J; Greenway, C V

    1987-11-01

    In dogs anesthetized with pentobarbital, central vena caval pressure (CVP), portal venous pressure (PVP), and intrahepatic lobar venous pressure (proximal to the hepatic venous sphincters) were measured. The objective was to determine some characteristics of the intrahepatic vascular resistance sites (proximal and distal to the hepatic venous sphincters) including testing predictions made using a recent mathematical model of distensible hepatic venous resistance. The stimulus used was a brief rise in CVP produced by transient occlusion of the thoracic vena cava in control state and when vascular resistance was elevated by infusions of norepinephrine or histamine, or by nerve stimulation. The percent transmission of the downstream pressure rise to upstream sites past areas of vascular resistance was elevated. Even small increments in CVP are partially transmitted upstream. The data are incompatible with the vascular waterfall phenomenon which predicts that venous pressure increments are not transmitted upstream until a critical pressure is overcome and then further increments would be 100% transmitted. The hepatic sphincters show the following characteristics. First, small rises in CVP are transmitted less than large elevations; as the CVP rises, the sphincters passively distend and allow a greater percent transmission upstream, thus a large rise in CVP is more fully transmitted than a small rise in CVP. Second, the amount of pressure transmission upstream is determined by the vascular resistance across which the pressure is transmitted. As nerves, norepinephrine, or histamine cause the hepatic sphincters to contract, the percent transmission becomes less and the distensibility of the sphincters is reduced. Similar characteristics are shown for the "presinusoidal" vascular resistance and the hepatic venous sphincter resistance.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Normal venous anatomy and physiology of the lower extremity.

    PubMed

    Notowitz, L B

    1993-06-01

    Venous disease of the lower extremities is common but is often misunderstood. It seems that the focus is on the exciting world of arterial anatomy and pathology, while the topic of venous anatomy and pathology comes in second place. However, venous diseases such as chronic venous insufficiency, leg ulcers, and varicose veins affect much of the population and may lead to disability and death. Nurses are often required to answer complex questions from the patients and his or her family about the patient's disease. Patients depend on nurses to provide accurate information in terms they can understand. Therefore it is important to have an understanding of the normal venous system of the legs before one can understand the complexities of venous diseases and treatments. This presents an overview of normal venous anatomy and physiology.

  9. Measurements Of Coronary Mean Transit Time And Myocardial Tissue Blood Flow By Deconvolution Of Intravasal Tracer Dilution Curves

    NASA Astrophysics Data System (ADS)

    Korb, H.; Hoeft, A.; Hellige, G.

    1984-10-01

    Previous studies have shown that intramyocardial blood volume does not vary to a major extent even during extreme variation of hemodynamics and coronary vascular tone. Based on a constant intramyocardial blood volume it is therefore possible to calculate tissue blood flow from the mean transit time of an intravascular tracer. The purpose of this study was to develop a clinically applicable method for measurement of coronary blood flow. The new method was based on indocyanine green, a dye which is bound to albumin and intravasally detectable by means of a fiberoptic catheter device. One fiberoptic catheter was placed in the aortic root and another in the coronary sinus. After central venous dye injection the resulting arterial and coronary venous dye dilution curves were processed on-line by a micro-computer. The mean transit time as well as myocardial blood flow were calculated from the step response function of the deconvoluted arterial and coronary venous signals. Reference flow was determined with an extracorporeal electromagnetic flowprobe within a coronary sinus bypass system. 38 steady states with coronary blood flow ranging from 49 - 333 ml/min*100g were analysed in 5 dogs. Mean transit times varied from 2.9 to 16.6 sec. An average intracoronary blood volume of 13.9 -7 1.8 m1/100g was calculated. The correlation between flow determined by the dye dilution technique and flow measured with the reference method was 0.98. According to these results determination of coronary blood flow with a double fiberoptic system and indocyanine green should be possible even under clinical conditions. Furthermore, the arterial and coronary venous oxygen saturation can be monitored continuously by the fiberoptic catheters. Therefore, additional information about the performance of the heart such as myocardial oxygen consumption and myocardial efficiency is available with the same equipment.

  10. [Risk factors for the development of venous insufficiency of the lower limbs during pregnancy--part 1].

    PubMed

    Ropacka-Lesiak, Mariola; Kasperczak, Jarosław; Breborowicz, Grzegorz H

    2012-12-01

    The venous system alters its function in pregnancy--the changes are both functional and structural. It becomes particularly vulnerable to the development of venous thrombosis and related complications. These adverse factors acting on the veins in pregnancy include: an increase in circulating blood volume, expansion of the uterus, weight gain, reduced physical activity hormonal changes. The changes in the plasma have a significant impact on the venous system. In pregnancy an increased level of fibrinogen and coagulation factors VII, VIII, IX and X, and von Willenbrand factor can be observed. Smooth muscle relaxation and relaxation of collagen fibers are caused by progesterone and estrogen, and it may result in the development of varicose veins, venous thrombosis and venous insufficiency The relationships between the hormones and the muscle pump efficiency has not been proven as yet. Estrogens cause an increase in the synthesis of coagulation proteins and it may result in the high risk of venous thrombosis and its consequences. Progesterone inhibits smooth muscle contraction, while estrogens cause relaxation and loosening of the bonds between the collagen fibers. The increase in the level of progesterone is of particular importance. It has a relaxing effect on the muscle, resulting in disorders of the vein shrinkage, affecting the increase of their capacity and valvular insufficiency, and valvular edges are not in contact with each other due to the vasodilatation. Estrogens have a similar effect, and additionally it may also cause an impairment in the collagen fibers connection and synthesis. This can result in the formation of telanglectasia without venous hypertension. Estrogens may also affect the synthesis of prostaglandins and nitric oxide. Estradiol inhibits vascular smooth muscle cell proliferation and stimulates cell migration and secretion of matrix proteins, as well as regeneration of the damaged vessels. Estrogen inhibits the production of cytokines

  11. Platelets Drive Thrombus Propagation in a Hematocrit and Glycoprotein VI-Dependent Manner in an In Vitro Venous Thrombosis Model.

    PubMed

    Lehmann, Marcus; Schoeman, Rogier M; Krohl, Patrick J; Wallbank, Alison M; Samaniuk, Joseph R; Jandrot-Perrus, Martine; Neeves, Keith B

    2018-05-01

    The objective of this study was to measure the role of platelets and red blood cells on thrombus propagation in an in vitro model of venous valvular stasis. A microfluidic model with dimensional similarity to human venous valves consists of a sinus distal to a sudden expansion, where for sufficiently high Reynolds numbers, 2 countercurrent vortices arise because of flow separation. The primary vortex is defined by the points of flow separation and reattachment. A secondary vortex forms in the deepest recess of the valve pocket characterized by low shear rates. An initial fibrin gel formed within the secondary vortex of a tissue factor-coated valve sinus. Platelets accumulated at the interface of the fibrin gel and the primary vortex. Red blood cells at physiological hematocrits were necessary to provide an adequate flux of platelets to support thrombus growth out of the valve sinus. A subpopulation of platelets that adhered to fibrin expose phosphatidylserine. Platelet-dependent thrombus growth was attenuated by inhibition of glycoprotein VI with a blocking Fab fragment or D-dimer. A 3-step process regulated by hemodynamics was necessary for robust thrombus propagation: First, immobilized tissue factor initiates coagulation and fibrin deposition within a low flow niche defined by a secondary vortex in the pocket of a model venous valve. Second, a primary vortex delivers platelets to the fibrin interface in a red blood cell-dependent manner. Third, platelets adhere to fibrin, activate through glycoprotein VI, express phosphatidylserine, and subsequently promote thrombus growth beyond the valve sinus and into the bulk flow. © 2018 American Heart Association, Inc.

  12. [Near-infrared spectroscopy in sepsis therapy : predictor of a low central venous oxygen saturation].

    PubMed

    Lichtenstern, C; Koch, C; Röhrig, R; Rosengarten, B; Henrich, M; Weigand, M A

    2012-10-01

    Early goal-directed hemodynamic optimization has become a cornerstone of sepsis therapy. One major defined goal is to achieve adequate central venous oxygen saturation (SO(2)). This study aimed to investigate the correlation between central venous SO(2) and frontal cerebral near-infrared spectroscopy (NIRS) measurement in patients with severe sepsis and septic shock. The NIRS method provides non-invasive measurement of regional oxygen saturation (rSO(2)) in tissues approximately 2 cm below the optical NIRS sensors which depends on arterial, capillary and venous blood. Thus this system gives site-specific real-time data about the balance of oxygen supply and demand. This was a secondary analysis from a prospective study of surgical intensive care (ICU) patients in the early phase of severe sepsis or septic shock. Bilateral cerebral rSO(2), central venous SO(2), arterial oxygen saturation (S(a)O(2)) and other surrogate parameters of oxygen supply, such as hemoglobin, partial pressure of oxygen and oxygen content in arterial blood were recorded. A total of 16 ICU patients (4 women, median age 65.5 years) were included in the study. As sepsis focus an intra-abdominal infection was detected in 62.5 % of patients, severe pneumonia was determined in 31.3 % and skin and soft tissue infections were recognized in 12.5 %. At study inclusion 50 % of patients had septic shock, the median sequential organ failure assessment (SOFA) score was 10.2 (interquartile range 5.25-8.75) and the median acute physiology and chronic health evaluation II (APACHE II) score was 26 (range 23.25-29.75). Mortality at day 28 was 37.5 %. Minimum rSO(2) (median 58) and right-sided rSO(2) (median 58) values showed a significant correlation in the analysis of receiver operating characteristics (area under the curve 0.844, p= 0.045). A central venous SO(2)< 70 % was indicated by rSO(2)< 56.5 with sensitivity and specificity of 75 % and 100 %, respectively. Cerebral NIRS could provide a fast and easily

  13. Venous leg ulcers

    PubMed Central

    2011-01-01

    Introduction Leg ulcers usually occur secondary to venous reflux or obstruction, but 20% of people with leg ulcers have arterial disease, with or without venous disorders. Between 1.5 and 3.0/1000 people have active leg ulcers. Prevalence increases with age to about 20/1000 in people aged over 80 years. Methods and outcomes We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of standard treatments, adjuvant treatments, and organisational interventions for venous leg ulcers? What are the effects of advice about self-help interventions in people receiving usual care for venous leg ulcers? What are the effects of interventions to prevent recurrence of venous leg ulcers? We searched: Medline, Embase, The Cochrane Library, and other important databases up to June 2011 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). Results We found 101 systematic reviews, RCTs, or observational studies that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. Conclusions In this systematic review we present information relating to the effectiveness and safety of the following interventions: compression bandages and stockings, cultured allogenic (single or bilayer) skin replacement, debriding agents, dressings (cellulose, collagen, film, foam, hyaluronic acid-derived, semi-occlusive alginate), hydrocolloid (occlusive) dressings in the presence of compression, intermittent pneumatic compression, intravenous prostaglandin E1, larval therapy, laser treatment (low-level), leg ulcer clinics, multilayer elastic system, multilayer elastomeric (or non-elastomeric) high-compression regimens or bandages, oral treatments (aspirin, flavonoids

  14. ABO blood group in primary antiphospholipid syndrome: influence in the site of thrombosis?

    PubMed

    Nascimento, Natália Mastantuono; Bydlowski, Sergio Paulo; Soares, Rosangela Paula Silva; de Andrade, Danieli Castro Oliveira; Bonfá, Eloísa; Seguro, Luciana Parente Costa; Borba, Eduardo Ferreira

    2015-10-01

    Antiphospholipid syndrome (APS) is characterized by vascular thrombosis and/or obstetric complications associated with presence of antiphospholipid antibodies (aPL) but additional factors would also induce thrombosis. ABO (H) blood groups are known to be closely related to thrombosis, especially non-O blood type with venous events. The aim of this study was to investigate possible role of ABO (H) blood types in the thrombotic events in primary APS (PAPS). Seventy PAPS patients were selected for the study and were divided according to ABO blood group in: O PAPS (n = 26) and non-O PAPS (n = 44). ABO blood group phenotyping was performed by indirect technique. aPL anticardiolipin (aCL) and anti-βeta2 glycoprotein-1 (aβ2GPI) and the concentrations and activities of von Willebrand factor (VWF) were measured with ELISA. Lupus anticoagulant (LA) was detected by coagulation assays. A significant higher frequency of venous events was observed in non-O PAPS group (72.7 vs. 46.2 %, p = 0.040). In contrast, the frequency of arterial events was significantly higher in the O PAPS compared to the non-O PAPS group (69.2 vs. 36.4 %, respectively; p = 0.013). Frequencies of aCL, LA, aβ2GPI and triple aPL positivity were similar in both groups (p > 0.05). VWF antigen (75.54 ± 8.68 vs. 79.51 ± 7.07 IU/dl, p = 0.041) and activity (70.23 ± 11.96 vs. 77.92 ± 13.67 %, p = 0.020) were decreased in O PAPS compared to non-O blood group. VWF:CB/VWF:Ag ratio was similar among groups (p > 0.05). This is the first report that confirms the role of ABO blood system in thrombosis of PAPS and suggests that non-O blood group was related with venous events and O blood group with arterial thrombosis.

  15. A remote and non-contact method for obtaining the blood-pulse waveform with a laser Doppler vibrometer

    NASA Astrophysics Data System (ADS)

    Desjardins, Candida L.; Antonelli, Lynn T.; Soares, Edward

    2007-02-01

    The use of lasers to remotely and non-invasively detect the blood pressure waveform of humans and animals would provide a powerful diagnostic tool. Current blood pressure measurement tools, such as a cuff, are not useful for burn and trauma victims, and animals require catheterization to acquire accurate blood pressure information. The purpose of our sensor method and apparatus invention is to remotely and non-invasively detect the blood pulse waveform of both animals and humans. This device is used to monitor an animal or human's skin in proximity to an artery using radiation from a laser Doppler vibrometer (LDV). This system measures the velocity (or displacement) of the pulsatile motion of the skin, indicative of physiological parameters of the arterial motion in relation to the cardiac cycle. Tests have been conducted that measures surface velocity with an LDV and a signal-processing unit, with enhanced detection obtained with optional hardware including a retro-reflector dot. The blood pulse waveform is obtained by integrating the velocity signal to get surface displacement using standard signal processing techniques. Continuous recording of the blood pulse waveform yields data containing information on cardiac health and can be analyzed to identify important events in the cardiac cycle, such as heart rate, the timing of peak systole, left ventricular ejection time and aortic valve closure. Experimental results are provided that demonstrates the current capabilities of the optical, non-contact sensor for the continuous, non-contact recording of the blood pulse waveform without causing patient distress.

  16. Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

    PubMed

    Duan, Xu; Ling, Feng; Shen, Yun; Yang, Jun; Xu, Hai-ying; Tong, Xiao-shan

    2013-04-01

    We investigated the efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation. A total of 40 consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantations were included in the study. Patients were randomly assigned to control group and nitroglycerin group. Patients in the nitroglycerin group were given 200 µg (2 mL) nitroglycerin via ipsilateral peripheral vein about 3 min before puncture. The degree of venous spasm was evaluated by the reduction in lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in lumen calibre of 50-90% and ≥ 90%, respectively. The mean degree of venous spasm of axillary vein was lower in the nitroglycerin group than in the control group (23.0 ± 22.3 vs. 45.5 ± 33.6%, P = 0.018). The incidence of mild or severe venous spasm was lower in the nitroglycerin group than in the control group (3/20 vs. 11/20, P = 0.019). In the nitroglycerin group, the systolic blood pressure had a significant decrease after puncture (129.5 ± 23.7 vs. 143.0 ± 24.1 mmHg, P = 0.003). There was no hypotension and other adverse reaction of nitroglycerin in the nitroglycerin group. Intravenous nitroglycerin is effective and safe for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

  17. Noninvasive optoacoustic monitoring of cerebral venous blood oxygenation in newborns

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Wynne, Karon E.; Petrov, Yuriy; Esenaliev, Rinat O.; Richardson, C. Joan; Prough, Donald S.

    2012-02-01

    Cerebral ischemia after birth and during labor is a major cause of death and severe complications such as cerebral palsy. In the USA alone, cerebral palsy results in permanent disability of 10,000 newborns per year and approximately 500,000 of the total population. Currently, no technology is capable of direct monitoring of cerebral oxygenation in newborns. This study proposes the use of an optoacoustic technique for noninvasive cerebral ischemia monitoring by probing the superior sagittal sinus (SSS), a large central cerebral vein. We developed and built a multi-wavelength, near-infrared optoacoustic system suitable for noninvasive monitoring of cerebral ischemia in newborns with normal weight (NBW), low birth-weight (LBW, 1500 - 2499 g) and very low birth-weight (VLBW, < 1500 g). The system was capable of detecting SSS signals through the open anterior and posterior fontanelles as well as through the skull. We tested the system in NBW, LBW, and VLBW newborns (weight range: from 675 g to 3,000 g) admitted to the neonatal intensive care unit. We performed single and continuous measurements of the SSS blood oxygenation. The data acquisition, processing and analysis software developed by our group provided real-time, absolute SSS blood oxygenation measurements. The SSS blood oxygenation ranged from 60% to 80%. Optoacoustic monitoring of the SSS blood oxygenation provides valuable information because adequate cerebral oxygenation would suggest that no therapy was necessary; conversely, evidence of cerebral ischemia would prompt therapy to increase cerebral blood flow.

  18. Low central venous pressure with milrinone during living donor hepatectomy.

    PubMed

    Ryu, H-G; Nahm, F S; Sohn, H-M; Jeong, E-J; Jung, C-W

    2010-04-01

    Maintaining a low central venous pressure (CVP) has been frequently used in liver resections to reduce blood loss. However, decreased preload carries potential risks such as hemodynamic instability. We hypothesized that a low CVP with milrinone would provide a better surgical environment and hemodynamic stability during living donor hepatectomy. Thirty-eight healthy adult liver donors were randomized to receive either milrinone (milrinone group, n = 19) or normal saline (control group, n = 19) infusion during liver resection. The surgical field was assessed using a four-point scale. Intraoperative vital signs, blood loss, the use of vasopressors and diuretics and postoperative laboratory data were compared between groups. The milrinone group showed a superior surgical field (p < 0.001) and less blood loss (142 +/- 129 mL vs. 378 +/- 167 mL, p < 0.001). Vital signs were well maintained in both groups but the milrinone group required smaller amounts of vasopressors and less-frequent diuretics to maintain a low CVP. The milrinone group also showed a more rapid recovery pattern after surgery. Milrinone-induced low CVP improves the surgical field with less blood loss during living donor hepatectomy and also has favorable effects on intraoperative hemodynamics and postoperative recovery.

  19. Comparison Between Retrograde and Antegrade Peripheral Venous Cannulation in Intensive Care Unit Patients: Assessment of Thrombus Formation.

    PubMed

    Abdelaal Ahmed Mahmoud, Ahmed; El-Shafei, Hassan Ismail; Yassin, Hany Mahmoud; Elramely, Mohamed Adly; Abdelhaq, Mohamed Mohamed; El Kady, Hany Wafiq; Awada, Wael Nabil Fahemy

    2017-06-01

    Antegrade cannulation of peripheral veins is the usual practice. Blood stasis between a catheter and the wall of the vein or at its tip in addition to catheter-induced phlebitis may initiate a thrombosis. The use of retrograde ventriculojugular shunts against the direction of the blood flow with resultant decrease in the incidence of venous thrombosis encouraged us to compare retrograde versus conventional antegrade peripheral venous cannulation. Monocentric, nonblinded, prospective observational cohort of 40 intensive care unit patients receiving 2 peripheral venous catheters in upper limbs, 1 inserted in the direction of blood flow (antegrade cannula) and the other inserted in an opposite direction to blood flow (retrograde cannula). Daily ultrasound assessment of the angle between the catheter and the vascular wall was done to detect onset and progression of thrombus formation. The study included 40 patients, aged 46.7 ± 10.132 years. The incidence of thrombus formation was 100% in both techniques. The onset time of thrombus formation between the catheter and the wall of a vein was significantly longer with the retrograde catheters than with the antegrade catheters with median time (interquartile range [range]) 6 days (5-6.75 [4-8]) with 95% confidence interval (CI), 5.58-6.42 vs 3 days (3-4 [2-5]) with 95% CI (2.76-3.24), respectively, with a P value <.001. The time needed by the recently detected thrombus to reach the catheter tip determined by ultrasound with or without catheter failure was significantly longer in the retrograde catheters than in the antegrade catheter with median time (interquartile range [range]) 9 days (8-9 [7-10]) with 95% CI, 8.76-9.24 vs 4 days (4-5 [3-6]) with 95% CI, 3.76-4.24, respectively, with a P value <.001. Retrograde cannulation did not decrease the incidence of thrombus formation, but significantly increased the onset time until thrombus formation and prolonged the time needed by the newly formed thrombus to reach the

  20. Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao Yue, E-mail: yuecao@umich.edu; Department of Radiology, University of Michigan, Ann Arbor, Michigan; Wang Hesheng

    2013-01-01

    Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation betweenmore » mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver

  1. One dimensional blood flow in a planetocentric orbit

    NASA Astrophysics Data System (ADS)

    Haranas, Ioannis; Gkigkitzis, Ioannis

    2012-05-01

    All life on earth is accustomed to the presence of gravity. When gravity is altered, biological processes can go awry. It is of great importance to ensure safety during a spaceflight. Long term exposure to microgravity can trigger detrimental physiological responses in the human body. Fluid redistribution coupled with fluid loss is one of the effects. In particular, in microgravity blood volume is shifted towards the thorax and head. Sympathetic nervous system-induced vasoconstriction is needed to maintain arterial pressure, while venoconstriction limits venous pooling of blood prevents further reductions in venous return of blood to the heart. In this paper, we modify an existing one dimensional blood flow model with the inclusion of the hydrostatic pressure gradient that further depends on the gravitational field modified by the oblateness and rotation of the Earth. We find that the velocity of the blood flow VB is inversely proportional to the blood specific volume d, also proportional to the oblateness harmonic coefficient J2, the angular velocity of the Earth ωE, and finally proportional to an arbitrary constant c. For c = -0.39073 and ξH = -0.5 mmHg, all orbits result to less blood flow velocities than that calculated on the surface of the Earth. From all considered orbits, elliptical polar orbit of eccentricity e = 0.2 exhibit the largest flow velocity VB = 1.031 m/s, followed by the orbits of inclination i = 45°and 0°. The Earth's oblateness and its rotation contribute a 0.7% difference to the blood flow velocity.

  2. Acute venous sinus thrombosis after chickenpox infection.

    PubMed

    Sardana, Vijay; Mittal, Lal Chand; Meena, S R; Sharma, Deepti; Khandelwal, Girish

    2014-08-01

    Chickenpox is one of the classic childhood diseases. Recently chicken pox has been reported in adults with more severe systemic and neurological complications. Cerebral venous thrombosis (CVT) is a life threatening disorder if not treated in time. We report a patient with post varicella CVT as a rare complication of primary Varicella zoster virus. Vasculitic arterial infarction is known while venous stroke has rarely been reported with Varicella-zoster virus infection. Here, we report an immunocompetent 30 yr old male who developed chickenpox after contact with his daughter two month back. He presented with acute neurological deficit, one week after onset of skin lesion. MR venography revealed non-visualisation of left transverse sinus and left sigmoid sinus suggestive of venous sinus thrombosis. Varicella infection is rarely associated with venous sinus thrombosis. Possibly hypercoagulable state produced by the infection or direct invasion of virus in venous endothelial wall with subsequent damage to endothelium leading to thrombosis could be the cause.

  3. Central venous recanalization in patients with short gut syndrome: restoration of candidacy for intestinal and multivisceral transplantation.

    PubMed

    Lang, Elvira V; Reyes, Jorge; Faintuch, Salomao; Smith, Amy; Abu-Elmagd, Kareem

    2005-09-01

    To assess feasibility and success of venous recanalization in patients with short gut syndrome who have lost their traditional central venous access and required intestinal or multivisceral transplantation. Twelve patients between the ages of 7 and 55 years with short gut syndrome and long-standing total parenteral nutrition (TPN) dependency and/or hypercoagulability were treated. All had extensive chronic central venous occlusions and survival was dependent on restoration of access and planned transplantation. Central venous recanalizations were obtained via sharp needle recanalization techniques, venous reconstructions with stents, and/or extraanatomic access to the central venous system for placement of central venous tunneled catheters. Central venous access was restored in all patients without operative-related mortality. Three major hemodynamic perioperative technical complications were recorded and successfully treated. There were three self-limited early infectious complications. With a mean follow-up of 22 months, eight of the 12 patients were alive with successful small bowel or multivisceral transplantation; six of those became independent of TPN. The remaining four patients died of complications related to TPN (n = 3) or transplantation (n = 1). With a mean follow-up of 20 months, all but two of the recanalized venous accesses were maintained, for a success rate of 83%. Recanalizations of extensive chronic vein occlusions are feasible but associated with high risk. The technique is life-saving for TPN-dependent patients and can restore candidacy for intestinal and multivisceral transplantation. This approach is likely to be increasingly requested because of the current clinical availability of the transplant procedure.

  4. Quantification of multiple elements in dried blood spot samples.

    PubMed

    Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads; Nybo, Mads

    2017-08-01

    Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. Elements were extracted from punches and analyzed using inductively coupled plasma-mass spectrometry (ICP-MS). The method was evaluated with quality controls with defined element concentration and blood spiked with elements to assess accuracy and imprecision. DBS element concentrations were compared with concentrations in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K, Fe, Cu, Zn, As and Se in DBS and venous whole blood. Hematocrit influenced the DBS element measurement, especially for K, Fe and Zn. Trace elements can be measured with high accuracy and low imprecision in DBS, but contribution of signal from the filter paper influences measurement of some elements present at low concentrations. Simultaneous measurement of K and Fe in DBS extracts may be used to estimate sample hematocrit. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. [Basic studies on oral administration of lentinan (I)--influence on lymphocyte subsets in peripheral venous blood].

    PubMed

    Hanaue, H; Tokuda, Y; Machimura, T; Tsukui, M; Mizutani, K; Huang, C M; Kamijoh, A; Kondo, Y; Ogoshi, K; Makuuchi, H

    1989-08-20

    The effect of oral administration of lentinan (LTN), a biological response modifier, in the control of systemic immune function was studied in 6-week old male Wistar-Imamichi SPF rats. In the LTN group, 1 mg LTN dissolved in 1 ml physiological saline was administration forcibly into the stomach twice weekly. Physiological saline alone was administered in a similar fashion to the control group. Blood samples were obtained prior to and after four and eight weeks of administration. White blood cells and lymphocyte counts were obtained and lymphocyte subsets were measured using monoclonal antibodies W3/13, W3/25 and 0 X 8 (Sera-Lab), and a laser flow cytometry system (Orthospectrum III, Orthodiagnostic System). The T cell ratio, helper/inducer T (Th) cell ratio, and suppressor/cytotoxic T (Ts) cell ratio were measured. The peripheral white blood cell count and lymphocyte count were not significantly different between the control and LTN groups. After four weeks of LTN administration, however, the LTN group showed a significantly higher T cell ratio, Th cell ratio and Th/Ts cell ratio than did the control group, and the Ts cell ratio was significantly lower. In the groups undergoing administration for eight weeks, no difference was noted in the lymphocyte subsets between the two groups. Oral administration of LTN apparently modulates the systemic immune function through T cell stimulation, especially Th cells, but continued administration may induce a tolerance to the effect of LTN.

  6. Intermittent hemodialysis is superior to continuous veno-venous hemodialysis/hemodiafiltration to eliminate methanol and formate during treatment for methanol poisoning

    PubMed Central

    Zakharov, Sergey; Pelclova, Daniela; Navratil, Tomas; Belacek, Jaromir; Kurcova, Ivana; Komzak, Ondrej; Salek, Tomas; Latta, Jiri; Turek, Radovan; Bocek, Robert; Kucera, Cyril; Hubacek, Jaroslav A; Fenclova, Zdenka; Petrik, Vit; Cermak, Martin; Hovda, Knut Erik

    2014-01-01

    During an outbreak of methanol poisonings in the Czech Republic in 2012, we were able to study methanol and formate elimination half-lives during intermittent hemodialysis (IHD) and continuous veno-venous hemodialysis/hemodiafiltration (CVVHD/HDF) and the relative impact of dialysate and blood flow rates on elimination. Data were obtained from 11 IHD and 13 CVVHD/HDF patients. Serum methanol and formate concentrations were measured by gas chromatography and an enzymatic method. The groups were relatively comparable, but the CVVHD/HDF group was significantly more acidotic (mean pH 6.9 vs. 7.1 IHD). The mean elimination half-life of methanol was 3.7 and formate 1.6 h with IHD, versus 8.1 and 3.6 h, respectively, with CVVHD/HDF (both significant). The 54% greater reduction in methanol and 56% reduction in formate elimination half-life during IHD resulted from the higher blood and dialysate flow rates. Increased blood and dialysate flow on the CVVHD/HDF also increased elimination significantly. Thus, IHD is superior to CVVHD/HDF for more rapid methanol and formate elimination, and if CVVHD/HDF is the only treatment available then elimination is greater with greater blood and dialysate flow rates. PMID:24621917

  7. Continuous monitoring of blood volume changes in humans

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.; Greenleaf, J. E.

    1987-01-01

    Use of on-line high-precision mass densitometry for the continuous monitoring of blood volume changes in humans was demonstrated by recording short-term blood volume alterations produced by changes in body position. The mass density of antecubital venous blood was measured continuously for 80 min per session with 0.1 g/l precision at a flow rate of 1.5 ml/min. Additional discrete plasma density and hematocrit measurements gave linear relations between all possible combinations of blood density, plasma density, and hematocrit. Transient filtration phenomena were revealed that are not amenable to discontinuous measurements.

  8. History of venous leg ulcers.

    PubMed

    Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G

    To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).

  9. D-Dimer and prothrombin fragment 1 + 2 in urine and plasma in patients with clinically suspected venous thromboembolism.

    PubMed

    Wexels, Fredrik; Seljeflot, Ingebjørg; Pripp, Are H; Dahl, Ola E

    2016-06-01

    Increased levels of urine prothrombin fragment 1 + 2 was recently reported to be associated with imaging-verified venous thromboembolism. In this study we evaluated the relationship between plasma D-dimer and plasma and urine prothrombin fragment 1 + 2 in patients with suspected venous thromboembolism. Urine and blood samples were collected from patients with suspected pulmonary embolism or deep vein thrombosis. The samples were analysed with commercially available ELISA kits. The diagnosis of venous thromboembolism was verified with contrast-enhanced computer tomography of the pulmonary arteries or lower extremity deep vein compression ultrasound and venography as appropriate. Venous thromboembolism was diagnosed in 150 of 720 patients. Significantly higher levels of plasma D-dimer and prothrombin fragment 1 + 2 in plasma and urine were found in those with imaging-confirmed venous thromboembolism versus those without (P < 0.001). The correlation between the three biomarkers was statistically significant (range of rs values 0.45-0.65, P < 0.001). Plasma D-dimer had the highest diagnostic accuracy followed by prothrombin fragment 1 + 2 in plasma. Further development of ELISA analyses for urine testing of prothrombin fragment 1 + 2 may improve its diagnostic accuracy.

  10. Contribution of voltage-dependent K+ channels to metabolic control of coronary blood flow

    PubMed Central

    Berwick, Zachary C.; Dick, Gregory M.; Moberly, Steven P.; Kohr, Meredith C.; Sturek, Michael; Tune, Johnathan D.

    2011-01-01

    The purpose of this investigation was to test the hypothesis that KV channels contribute to metabolic control of coronary blood flow and that decreases in KV channel function and/or expression significantly attenuate myocardial oxygen supply-demand balance in the metabolic syndrome (MetS). Experiments were conducted in conscious, chronically instrumented Ossabaw swine fed either a normal maintenance diet or an excess calorie atherogenic diet that produces the clinical phenotype of early MetS. Data were obtained under resting conditions and during graded treadmill exercise before and after inhibition of KV channels with 4-aminopyridine (4-AP, 0.3 mg/kg, i.v.). In lean-control swine, 4-AP reduced coronary blood flow ~15% at rest and ~20% during exercise. Inhibition of KV channels also increased aortic pressure (P < 0.01) while reducing coronary venous Po2 (P < 0.01) at a given level of myocardial oxygen consumption (MVo2). Administration of 4-AP had no effect on coronary blood flow, aortic pressure, or coronary venous Po2 in swine with MetS. The lack of response to 4-AP in MetS swine was associated with a ~20% reduction in coronary KV current (P < 0.01) and decreased expression of KV1.5 channels in coronary arteries (P < 0.01). Together, these data demonstrate that KV channels play an important role in balancing myocardial oxygen delivery with metabolism at rest and during exercise-induced increases in MVo2. Our findings also indicate that decreases in KV channel current and expression contribute to impaired control of coronary blood flow in the MetS. PMID:21771599

  11. Detection of emetic activity in the cat by monitoring venous pressure and audio signals

    NASA Technical Reports Server (NTRS)

    Nagahara, A.; Fox, Robert A.; Daunton, Nancy G.; Elfar, S.

    1991-01-01

    To investigate the use of audio signals as a simple, noninvasive measure of emetic activity, the relationship between the somatic events and sounds associated with retching and vomiting was studied. Thoracic venous pressure obtained from an implanted external jugular catheter was shown to provide a precise measure of the somatic events associated with retching and vomiting. Changes in thoracic venous pressure monitored through an indwelling external jugular catheter with audio signals, obtained from a microphone located above the animal in a test chamber, were compared. In addition, two independent observers visually monitored emetic episodes. Retching and vomiting were induced by injection of xylazine (0.66mg/kg s.c.), or by motion. A unique audio signal at a frequency of approximately 250 Hz is produced at the time of the negative thoracic venous pressure change associated with retching. Sounds with higher frequencies (around 2500 Hz) occur in conjunction with the positive pressure changes associated with vomiting. These specific signals could be discriminated reliably by individuals reviewing the audio recordings of the sessions. Retching and those emetic episodes associated with positive venous pressure changes were detected accurately by audio monitoring, with 90 percent of retches and 100 percent of emetic episodes correctly identified. Retching was detected more accurately (p is less than .05) by audio monitoring than by direct visual observation. However, with visual observation a few incidents in which stomach contents were expelled in the absence of positive pressure changes or detectable sounds were identified. These data suggest that in emetic situations, the expulsion of stomach contents may be accomplished by more than one neuromuscular system and that audio signals can be used to detect emetic episodes associated with thoracic venous pressure changes.

  12. Current Status of the Application of Intracranial Venous Sinus Stenting

    PubMed Central

    Xu, Kan; Yu, Tiecheng; Yuan, Yongjie; Yu, Jinlu

    2015-01-01

    The intracranial venous sinus is an important component of vascular disease. Many diseases involve the venous sinus and are accompanied by venous sinus stenosis (VSS), which leads to increased venous pressure and high intracranial pressure. Recent research has focused on stenting as a treatment for VSS related to these diseases. However, a systematic understanding of venous sinus stenting (VS-Stenting) is lacking. Herein, the literature on idiopathic intracranial hypertension (IIH), venous pulsatile tinnitus, sinus thrombosis, high draining venous pressure in dural arteriovenous fistula (AVF) and arteriovenous malformation (AVM), and tumor-caused VSS was reviewed and analyzed to summarize experiences with VS-Stenting as a treatment. The literature review showed that satisfactory therapeutic effects can be achieved through stent angioplasty. Thus, the present study suggests that selective stent release in the venous sinus can effectively treat these diseases and provide new possibilities for treating intracranial vascular disease. PMID:26516306

  13. Capillary blood sampling as an alternative to venipuncture in the assessment of serum 25 hydroxyvitamin D levels.

    PubMed

    Dayre McNally, J; Matheson, Loren A; Sankaran, Koravangattu; Rosenberg, Alan M

    2008-11-01

    This study compared 25-hydroxyvitamin D [25(OH)D] measurements in capillary and venous blood samples collected, respectively by fingerprick and venipuncture. Capillary blood for measuring 25(OH)D has potential advantages by reducing blood volume required (2mL versus 0.3mL for venipuncture and capillary sampling, respectively), facilitating blood collection for those populations in whom venipuncture is difficult (e.g. infants and children), improving patient convenience and reducing costs associated with phlebotomy. The results demonstrated a highly significant relationship between 25(OH)D levels in serum derived from venous and capillary blood samples (r(2)=0.901). Despite statistically higher 25(OH)D levels in fingerprick samples (108+/-9nmol/L) compared with venipuncture samples (90+/-7nmol/L), the correlation between venous and capillary samples provides support for this approach as a practical alternative to venipuncture for vitamin D determination. However, clinical application may require the incorporation of a correction factor for the assessment of insufficiency, and research studies should avoid using the two methods interchangeably. Studying vitamin D's role in health and disease requires collection techniques and measurement methods that are reliable, reproducible, easily accessible, inexpensive and minimally burdensome to the patient. The option to collect patient samples by fingerprick may facilitate the collection process.

  14. Matrix Metalloproteinases as Regulators of Vein Structure and Function: Implications in Chronic Venous Disease.

    PubMed

    MacColl, Elisabeth; Khalil, Raouf A

    2015-12-01

    Lower-extremity veins have efficient wall structure and function and competent valves that permit upward movement of deoxygenated blood toward the heart against hydrostatic venous pressure. Matrix metalloproteinases (MMPs) play an important role in maintaining vein wall structure and function. MMPs are zinc-binding endopeptidases secreted as inactive pro-MMPs by fibroblasts, vascular smooth muscle (VSM), and leukocytes. Pro-MMPs are activated by various activators including other MMPs and proteinases. MMPs cause degradation of extracellular matrix (ECM) proteins such as collagen and elastin, and could have additional effects on the endothelium, as well as VSM cell migration, proliferation, Ca(2+) signaling, and contraction. Increased lower-extremity hydrostatic venous pressure is thought to induce hypoxia-inducible factors and other MMP inducers/activators such as extracellular matrix metalloproteinase inducer, prostanoids, chymase, and hormones, leading to increased MMP expression/activity, ECM degradation, VSM relaxation, and venous dilation. Leukocyte infiltration and inflammation of the vein wall cause further increases in MMPs, vein wall dilation, valve degradation, and different clinical stages of chronic venous disease (CVD), including varicose veins (VVs). VVs are characterized by ECM imbalance, incompetent valves, venous reflux, wall dilation, and tortuosity. VVs often show increased MMP levels, but may show no change or decreased levels, depending on the VV region (atrophic regions with little ECM versus hypertrophic regions with abundant ECM) and MMP form (inactive pro-MMP versus active MMP). Management of VVs includes compression stockings, venotonics, and surgical obliteration or removal. Because these approaches do not treat the causes of VVs, alternative methods are being developed. In addition to endogenous tissue inhibitors of MMPs, synthetic MMP inhibitors have been developed, and their effects in the treatment of VVs need to be examined

  15. Blood circulation in the lower limbs

    NASA Astrophysics Data System (ADS)

    Pen'kovskiy, V. I.; Korsakova, N. K.

    2018-03-01

    Blood circulation process in inferior limbs is considered in the terms of the previously proposed mathematical model of sanguimotion in living organism tissues. The model includes the equations of homogeneous fluid flower in heterogeneous medium that consists of two or more interpenetrating continua. The continua (distributing net of arteries and collecting net of veins) interact through ramified capillary net. A volume of blood flowering from arterial net to venous one is proportional to pressure (head) difference in the nets. Some analytical solutions and numerical results are given.

  16. Qualitative Slow Blood Flow in Lower Extremity Deep Veins on Doppler Sonography: Quantitative Assessment and Preliminary Evaluation of Correlation With Subsequent Deep Venous Thrombosis Development in a Tertiary Care Oncology Center.

    PubMed

    Jensen, Corey T; Chahin, Antoun; Amin, Veral D; Khalaf, Ahmed M; Elsayes, Khaled M; Wagner-Bartak, Nicolaus; Zhao, Bo; Zhou, Shouhao; Bedi, Deepak G

    2017-09-01

    To determine whether the qualitative sonographic appearance of slow deep venous flow in the lower extremities correlates with quantitative slow flow and an increased risk of deep venous thrombosis (DVT) in oncology patients. In this Institutional Review Board-approved retrospective study, we reviewed lower extremity venous Doppler sonographic examinations of 975 consecutive patients: 482 with slow flow and 493 with normal flow. The subjective slow venous flow and absence of initial DVT were confirmed by 2 radiologists. Peak velocities were recorded at 3 levels. Each patient was followed for DVT development. The associations between DVT and the presence of slow venous flow were examined by the Fisher exact test; a 2-sample t test was used for peak velocity and DVT group comparisons. The optimal cutoff peak velocity for correlation with the radiologists' perceived slow flow was determined by the Youden index. Deep venous thrombosis development in the slow-flow group (21 of 482 [4.36%]) was almost doubled compared with patients who had normal flow (11 of 493 [2.23%]; P = .0456). Measured peak venous velocities were lower in the slow-venous flow group (P < .001). Patients with subsequent DVT did not have a significant difference in venous velocities compared with their respective patient groups. The sum of 3 venous level velocities resulted in the best cutoff for dichotomizing groups into normal versus slow venous flow. Qualitative slow venous flow in the lower extremities on Doppler sonography accurately correlates with quantitatively slower flow, and this preliminary evaluation suggests an associated mildly increased rate of subsequent DVT development in oncology patients. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Intracranial developmental venous anomaly: is it asymptomatic?

    PubMed

    Puente, A Bolívar; de Asís Bravo Rodríguez, F; Bravo Rey, I; Romero, E Roldán

    2018-03-16

    Intracranial developmental venous anomalies are the most common vascular malformation. In the immense majority of cases, these anomalies are asymptomatic and discovered incidentally, and they are considered benign. Very exceptionally, however, they can cause neurological symptoms. In this article, we present three cases of patients with developmental venous anomalies that presented with different symptoms owing to complications derived from altered venous drainage. These anomalies were located in the left insula, right temporal lobe, and cerebellum. The exceptionality of the cases presented as well as of the images associated, which show the mechanism through which the symptoms developed, lies in the low incidence of symptomatic developmental venous anomalies reported in the literature. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Cerebral blood velocity regulation during progressive blood loss compared with lower body negative pressure in humans.

    PubMed

    Rickards, Caroline A; Johnson, Blair D; Harvey, Ronée E; Convertino, Victor A; Joyner, Michael J; Barnes, Jill N

    2015-09-15

    Lower body negative pressure (LBNP) is often used to simulate blood loss in humans. It is unknown if cerebral blood flow responses to actual blood loss are analogous to simulated blood loss during LBNP. Nine healthy men were studied at baseline, during three levels of LBNP (5 min at -15, -30, and -45 mmHg), and during three levels of blood loss (333, 667, and 1,000 ml). LBNP and blood loss conditions were randomized. Intra-arterial mean arterial pressure (MAP) during LBNP was similar to that during blood loss (P ≥ 0.42). Central venous pressure (2.8 ± 0.7 vs. 4.0 ± 0.8, 1.2 ± 0.6 vs. 3.5 ± 0.8, and 0.2 ± 0.9 vs. 2.1 ± 0.9 mmHg for levels 1, 2, and 3, respectively, P ≤ 0.003) and stroke volume (71 ± 4 vs. 80 ± 3, 60 ± 3 vs. 74 ± 3, and 51 ± 2 vs. 68 ± 4 ml for levels 1, 2, and 3, respectively, P ≤ 0.002) were lower during LBNP than blood loss. Despite differences in central venous pressure, middle cerebral artery velocity (MCAv) and cerebrovascular conductance were similar between LBNP and blood loss at each level (MCAv at level 3: 62 ± 6 vs. 66 ± 5 cm/s, P = 0.37; cerebrovascular conductance at level 3: 0.72 ± 0.05 vs. 0.73 ± 0.05 cm·s(-1)·mmHg(-1), P = 0.53). While the slope of the MAP-MCAv relationship was slightly different between LBNP and blood loss (0.41 ± 0.03 and 0.66 ± 0.04 cm·s(-1)·mmHg(-1), respectively, P = 0.05), time domain gain between MAP and MCAv at maximal LBNP/blood loss (P = 0.23) and low-frequency MAP-mean MCAv transfer function coherence, gain, and phase were similar (P ≥ 0.10). Our results suggest that cerebral hemodynamic responses to LBNP to -45 mmHg and blood loss up to 1,000 ml follow a similar trajectory, and the arterial pressure-cerebral blood velocity relationship is not altered from baseline under these conditions.

  19. Effects of isokinetic calf muscle exercise program on muscle strength and venous function in patients with chronic venous insufficiency.

    PubMed

    Ercan, Sabriye; Çetin, Cem; Yavuz, Turhan; Demir, Hilmi M; Atalay, Yurdagül B

    2018-05-01

    Objective The aim of this study was to observe the change of the ankle joint range of motion, the muscle strength values measured with an isokinetic dynamometer, pain scores, quality of life scale, and venous return time in chronic venous insufficiency diagnosed patients by prospective follow-up after 12-week exercise program including isokinetic exercises. Methods The patient group of this study comprised 27 patients (23 female, 4 male) who were diagnosed with chronic venous insufficiency. An exercise program including isokinetic exercise for the calf muscle was given to patients three days per week for 12 weeks. At the end of 12 weeks, five of the patients left the study due to inadequate compliance with the exercise program. As a result, control data of 22 patients were included. Ankle joint range of active motion, isokinetic muscle strength, pain, quality of life, and photoplethysmography measurements were assessed before starting and after the exercise program. Results Evaluating changes of the starting and control data depending on time showed that all isokinetic muscle strength measurement parameters, range of motion, and overall quality of life values of patients improved. Venous return time values have also increased significantly ( p < 0.05). Conclusion In conclusion, increase in muscle strength has been provided with exercise therapy in patients with chronic venous insufficiency. It has been determined that the increase in muscle strength affected the venous pump and this ensured improvement in venous function and range of motion of the ankle. In addition, it has been detected that pain reduced and quality of life improved after the exercise program.

  20. Detection of deep venous thrombophlebitis by gallium 67 scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.H.

    1981-07-01

    Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.

  1. Detection of deep venous thrombophlebitis by Gallium 67 scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, J.H.

    1981-07-01

    Deep venous thrombophlebitis may escape clinical detection. Three cases are reported in which whole-body gallium 67 scintigraphy was used to detect unsuspected deep venous thrombophlebitis related to indwelling catheters in three children who were being evaluated for fevers of unknown origin. Two of these children had septicemia from Candida organisms secondary to these venous lines. Gallium 67 scintigraphy may be useful in the detection of complications of indwelling venous catheters.

  2. A randomized controlled trial of a mixed Kinesio taping-compression technique on venous symptoms, pain, peripheral venous flow, clinical severity and overall health status in postmenopausal women with chronic venous insufficiency.

    PubMed

    Aguilar-Ferrándiz, M Encarnación; Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Guisado-Barrilao, Rafael; García-Ríos, M Carmen; Moreno-Lorenzo, Carmen

    2014-01-01

    To investigate the effect of a mixed Kinesio taping treatment in women with chronic venous insufficiency. A double-blinded randomized clinical trial. Clinical setting. One hundred and twenty postmenopausal women with mild-moderate chronic venous insufficiency were randomly assigned to an experimental group receiving standardized Kinesio taping treatment for gastrocnemius muscle enhancement and ankle functional correction, or to a placebo control group for simulated Kinesio taping. MAIN OUTCOMES VARIABLES: Venous symptoms, pain, photoplethysmographic measurements, bioelectrical impedance, temperature, severity and overall health were recorded at baseline and after four weeks of treatment. The 2 × 2 mixed model ANCOVA with repeated measurements showed statistically significant group * time interaction for heaviness (F = 22.99, p = 0.002), claudication (F = 8.57, p = 0.004), swelling (F = 22.58, p = 0.001), muscle cramps (F = 7.14, p = 0.008), venous refill time (right: F = 9.45, p = 0.023; left: F = 14.86, p = 0.001), venous pump function (right: F = 35.55, p = 0.004; left: F = 17.39 p = 0.001), extracellular water (right: F = 35.55, p = 0.004; left: F = 23.84, p = 0.001), severity (F = 18.47, p = 0.001), physical function (F = 9.15, p = 0.003) and body pain (F = 3.36, p = 0.043). Both groups reported significant reduction in pain. Mixed Kinesio taping-compression therapy improves symptoms, peripheral venous flow and severity and slightly increases overall health status in females with mild chronic venous insufficiency. Kinesio taping may have a placebo effect on pain.

  3. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chibamore » needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.« less

  4. A study to evaluate patterns of superficial venous reflux in patients with primary chronic venous disease.

    PubMed

    Qureshi, Mahim I; Gohel, Manj; Wing, Louise; MacDonald, Andrew; Lim, Chung S; Ellis, Mary; Franklin, Ian J; Davies, Alun H

    2015-08-01

    This study assessed patterns of superficial reflux in patients with primary chronic venous disease. Retrospective review of all patient venous duplex ultrasonography reports at one institution between 2000 and 2009. Legs with secondary, deep or no superficial reflux were excluded. In total, 8654 limbs were scanned; 2559 legs from 2053 patients (mean age 52.3 years) were included for analysis. Great saphenous vein reflux predominated (68%), followed by combined great saphenous vein/small saphenous vein reflux (20%) and small saphenous vein reflux (7%). The majority of legs with competent saphenofemoral junction had below-knee great saphenous vein reflux (53%); incompetent saphenofemoral junction was associated with combined above and below-knee great saphenous vein reflux (72%). Isolated small saphenous vein reflux was associated with saphenopopliteal junction incompetence (61%), although the majority of all small saphenous vein reflux limbs had a competent saphenopopliteal junction (57%). Superficial venous reflux does not necessarily originate from a saphenous junction. Large prospective studies with interval duplex ultrasonography are required to unravel the natural history of primary chronic venous disease. © The Author(s) 2014.

  5. Low values of central venous oxygen saturation (ScvO2) during surgery and anastomotic leak of abdominal trauma patients.

    PubMed

    Isaza-Restrepo, Andres; Moreno-Mejia, Jose F; Martin-Saavedra, Juan S; Ibañez-Pinilla, Milciades

    2017-01-01

    There is a well known relationship between hypoperfusion and postoperative complications like anastomotic leak. No studies have been done addressing this relationship in the context of abdominal trauma surgery. Central venous oxygen saturation is an important hypoperfusion marker of potential use in abdominal trauma surgery for identifying the risk of anastomotic leak development. The purpose of this study was to identify the relationship between low values of central venous oxygen saturation and anastomotic leak of gastrointestinal sutures in the postoperative period in abdominal trauma surgery. A cross-sectional prospective study was performed. Patients over 14 years old who required surgical gastrointestinal repair secondary to abdominal trauma were included. Anastomotic leak diagnosis was confirmed through clinical manifestations and diagnostic images or secondary surgery when needed. Central venous oxygen blood saturation was measured at the beginning of surgery through a central catheter. Demographic data, trauma mechanism, anatomic site of trauma, hemoglobin levels, abdominal trauma index, and comorbidities were assessed as secondary variables. Patients who developed anastomotic leak showed lower mean central venous oxygen saturation levels (60.0% ± 2.94%) than those who did not (69.89% ± 7.21%) ( p  = 0.010). Central venous oxygen saturation <65% was associated with the development of gastrointestinal leak during postoperative time of patients who underwent surgery secondary to abdominal trauma.

  6. In-vitro Gd-DTPA Relaxometry Studies in Oxygenated Venous Human Blood and Aqueous Solution at 3 and 7T

    PubMed Central

    Kalavagunta, Chaitanya; Michaeli, Shalom; Metzger, Gregory J.

    2014-01-01

    In-vitro T1 and T2* relaxivities (r1 and r2*) of Gd-DTPA (GaD) in oxygenated human venous blood (OVB) and aqueous solution (AS) at 3T and 7T were calculated. GaD concentrations ([GaD]) in OVB and AS were prepared in the range 0–5 mM. All measurements were acquired at 37±2 °C. At both 3T and 7T, a linear relationship was observed between [GaD] and R1 in both AS and OVB. At 7T, r1 in AS decreased by 7.5% (p = 0.045) while there was a negligible change in OVB. With respect to R2*, a linear relationship with [GaD] was only observed in AS, while a more complex relationship was observed in OVB; quadratic below and linear above 2 mM at both field strengths. There was a significant increase of over four-fold in r2* with GaD in OVB at 7T (for [GaD] above 2mM, p ≪0.01) as compared to 3T. Furthermore, in comparison to r1, r2* in AS was less than two-fold higher at both field strengths while in OVB it was ~twenty-fold and ~ninety-fold higher at 3T and 7T, respectively. This observation emphasizes the importance of r2* knowledge at high magnetic fields, ≥3T. The comparison between r1 and r2* presented in this work is crucial in the design and optimization of high field MRI studies making use of paramagnetic contrast agents. This is especially true in multiple compartment systems such as blood where r2* dramatically increases while r1 remains relatively constant with increasing magnetic field strength. PMID:24523062

  7. Transcutaneous regional venous oximetry: a feasibility study.

    PubMed

    Thiele, Robert H; Tucker-Schwartz, Jason M; Lu, Yao; Gillies, George T; Durieux, Marcel E

    2011-06-01

    The arterial pulse oximeter, which was introduced clinically in the 1970s, is a convenient, useful, and now ubiquitous anesthesia monitor. Unfortunately, although percent saturation of arterial hemoglobin is, along with cardiac output and concentration of hemoglobin, one of 3 components of oxygen delivery, it does not indicate whether oxygen delivery to a region of interest is adequate. Knowledge of peripheral or regional venous oxygen saturation (Sxvo₂) may lend insight into analysis of regional oxygen supply and demand. Our goal was to assess the suitability of 3 anatomic sites for the transcutaneous assessment of Sxvo₂. Using a Nonin reflectance oximetry probe (provided by Nonin Medical, Plymouth, MN) placed directly over the antecubital, external jugular, and internal jugular veins in 10 volunteers, we measured the absorbance of red and infrared electromagnetic radiation. We performed fast Fourier transformation on these absorbance waveforms. The ratio of pulsatile absorbance of red and infrared radiation at different frequencies was compared with nonpulsatile absorption, and Sxvo₂ was calculated based on previously derived empiric correlations. Estimates of transcutaneous Sxvo₂ ranged from 41% to 97%, with mean values of 75%, 80%, and 80% at the antecubital, external jugular, and internal jugular veins, respectively. Overall, 93% of predicted Sxvo₂ values were < 90%. Validation and subsequent improvement of this technique requires correlation of our results with venous blood gas measurements, followed by incorporation of technologies from related fields in oximetry (fetal reflectance oximetry and near-infrared spectroscopy), as well as the development of advanced signal processing techniques.

  8. Three-dimensional venous anatomy of the dermis observed using stereography

    PubMed Central

    Imanishi, Nobuaki; Kishi, Kazuo; Chang, Hak; Nakajima, Hideo; Aiso, Sadakazu

    2008-01-01

    Veins of the dermis have been investigated mainly by histological methods in the fields of anatomy and histology, and a large number of schemata of the veins have been depicted in a variety of textbooks. However, the schemata are usually two-dimensional and it is therefore difficult to envisage the actual vasculature of the dermal veins. In this study, we performed a stereographic study of the skin of three fresh cadavers that had been injected with radio-opaque dye, which was dispersed throughout the entire body. A venous network consisting of venous polygons of various sizes existed just under the dermis or in the deep zone of the dermis, which is generally called the subdermal venous plexus. There were many small vessels towards the inside of each venous polygon, and most of them ascended, branching off stereoscopically. Those branches anastomosed with each other, and they formed the dermal and subpapillary venous plexuses. However, there was little vascular connection between dermal venous plexuses of different venous polygons. The characteristic structure of the dermal venous plexus has been considered to bring about venous congestion of the skin in various clinical situations. PMID:18422525

  9. White blood cell concentrations during lower body negative pressure and blood loss in humans.

    PubMed

    van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J

    2016-10-01

    What is the central question of this study? Is lower body negative pressure a useful surrogate to study white blood cell responses to haemorrhage in humans? What is the main finding and its importance? We found that lower body negative pressure appears to be a useful surrogate to study the early white blood cell mobilization response during blood loss. Hypovolaemia has been associated with an immune response that might be secondary to sympathoexcitation. We tested the hypothesis that simulated hypovolaemia using lower body negative pressure (LBNP) and real hypovolaemia induced via experimental blood loss (BL) cause similar increases in the white blood cell concentration ([WBC]). We measured [WBC] and catecholamine concentrations in 12 men who underwent an LBNP and a BL protocol in a randomized order. We compared 45 mmHg of LBNP with 1000 ml of BL; therefore, [WBC] and catecholamine concentrations were plotted against central venous pressure to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Mean regression line slopes were similar for total [WBC] (LBNP 183 ± 4 μl -1  mmHg -1 versus BL 155 ± 109 μl -1  mmHg -1 , P = 0.15), neutrophils (LBNP 110 ± 2 μl -1  mmHg -1 versus BL 96 ± 72 μl -1  mmHg -1 , P = 0.15) and lymphocytes (LBNP 65 ± 21 μl -1  mmHg -1  versus BL 59 ± 38 μl -1  mmHg -1 , P = 0.90). Mean regression line slopes for adrenaline were similar (LBNP 15 ± 5 pg ml -1  mmHg -1 versus BL 16 ± 4 pg ml -1  mmHg -1 , P = 0.84) and were steeper during LBNP for noradrenaline (LBNP 28 ± 6 pg ml -1  mmHg -1 versus BL 9 ± 6 pg ml -1  mmHg -1 , P = 0.01). These data indicate that central hypovolaemia elicits a relative leucocytosis with a predominantly neutrophil-based response. Additionally, our results indicate that LBNP models the stimulus-response relationship between central venous pressure and [WBC] observed during BL. © 2016 The Authors

  10. Comparison of the effectiveness of compression stockings and layer compression systems in venous ulceration treatment

    PubMed Central

    Jawień, Arkadiusz; Cierzniakowska, Katarzyna; Cwajda-Białasik, Justyna; Mościcka, Paulina

    2010-01-01

    Introduction The aim of the research was to compare the dynamics of venous ulcer healing when treated with the use of compression stockings as well as original two- and four-layer bandage systems. Material and methods A group of 46 patients suffering from venous ulcers was studied. This group consisted of 36 (78.3%) women and 10 (21.70%) men aged between 41 and 88 years (the average age was 66.6 years and the median was 67). Patients were randomized into three groups, for treatment with the ProGuide two-layer system, Profore four-layer compression, and with the use of compression stockings class II. In the case of multi-layer compression, compression ensuring 40 mmHg blood pressure at ankle level was used. Results In all patients, independently of the type of compression therapy, a few significant statistical changes of ulceration area in time were observed (Student’s t test for matched pairs, p < 0.05). The largest loss of ulceration area in each of the successive measurements was observed in patients treated with the four-layer system – on average 0.63 cm2/per week. The smallest loss of ulceration area was observed in patients using compression stockings – on average 0.44 cm2/per week. However, the observed differences were not statistically significant (Kruskal-Wallis test H = 4.45, p > 0.05). Conclusions A systematic compression therapy, applied with preliminary blood pressure of 40 mmHg, is an effective method of conservative treatment of venous ulcers. Compression stockings and prepared systems of multi-layer compression were characterized by similar clinical effectiveness. PMID:22419941

  11. Use of ultraportable vacuum therapy systems in the treatment of venous leg ulcer.

    PubMed

    Cuomo, Roberto; Nisi, Giuseppe; Grimaldi, Luca; Brandi, Cesare; D'Aniello, Carlo

    2017-10-23

    The high incidence of venous leg ulcers and the difficult to give a complete healing involves in an increase of costs for National Health System. Main therapies to obtain a fast healing are compressive bandages, treatment of abnormal venous flow and in-situ-strategies of wound care. Negative pressure therapy does not conventionally used, because these systems not allow the use of compression bandages. Recently the development of ultraportable devices has improved the compliance and the results. Ten patients with venous chronic ulcer on the lower extremities were recruited for this study: all patients had venous leg ulcers from at least one year. We treated the patients with autologous partial thickness skin graft and subsequently we applied NANOVA device included in compressive bandage. We used NANOVA for fourteen days and after we made traditional medications. We submitted a questionnaire to evaluate the impact of dressing and NANOVA device in the quality of life of patients. The device contributed to the formation of granulation tissue and increased the success rate of autologous skin graft without limiting mobility of patient. In addition to this, we have been able to perform compression bandages thanks to small size of this device. Eight ulcers healed within 90 days of medication. We believe that ultraportable negative pressure systems are useful devices for treatment of venous leg ulcers because them allows to realize a compressive bandage without mobility limitations.

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN BLOOD ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Blood data set contains analytical results for measurements of up to 2 metals in 86 blood samples over 86 households. Each sample was collected as a venous sample from the primary respondent within each household. The samples consisted of two 3-mL tubes. The prim...

  13. Performance of central venous catheterization by medical students: a retrospective study of students’ logbooks

    PubMed Central

    2014-01-01

    Background Medical students often learn the skills necessary to perform a central venous catheterization in the operating room after simulator training. We examined the performance of central venous catheterization by medical students from the logbooks during their rotation in department of anesthesiology. Methods From the logbooks of medical students rotating in our department between January 2011 and June 2012, we obtained the kind and the number of central venous catheterization students had done, the results of the procedures whether they were success or failed, the reasons of the failures, complications, and the student self-reported confidence and satisfaction of their performance. Results There were 93 medical students performed 875 central venous catheterizations with landmark guidance on patients in the operating theater, and the mean number of catheterizations performed per student was 9.4 ± 2.0, with a success rate of 67.3%. Adjusted for age, sex, body mass index, surgical category, ASA score and insertion site, the odds of successful catherization improved with cumulative practice (odds ratio 1.10 per additional central venous catheterization performed; 95% confidence interval 1.05–1.15). The major challenge students encountered during the procedure was the difficulty of finding the central veins, which led to 185 catheterizations failed. The complication rate of central venous catheterization by the students was 7.8%, while the most common complication was puncture of artery. The satisfaction and confidence of students regarding their performance increased with each additional procedure and decreased significantly if failure or complications had occurred. Conclusion A student logbook is a useful tool for recording the actual procedural performance of students. From the logbooks, we could see the students’ performance, challenges, satisfaction and confidence of central venous catheterization were improved through cumulative clinical practice of

  14. Does cryotherapy improve skin circulation compared with compression and elevation in preventing venous leg ulcers?

    PubMed

    Kelechi, Teresa J; Mueller, Martina; Madisetti, Mohan; Prentice, Margie A; Dooley, Mary J

    2017-08-01

    This trial compared skin blood flow, temperature and incidence of venous leg ulcers in patients with chronic venous disease using compression wraps and elevation pillows. Patients with CEAP C4 skin damage and C5 history of ulcers were randomly assigned to a cryotherapy intervention (n = 138) or placebo cuff control (n = 138) applied to the lower legs over 9 months. The time the ulcers healed prior to enrollment in the study for the cryotherapy group ranged from 1 to 2218 days (n = 8, median = 32 days); for the control group, the range was 24 to 489 days (n = 6, median = 390 days). There were no statistically significant blood flow changes measured in perfusion units with a laser Doppler flowmetre within or between the groups; mean difference between the groups was 0·62, P = 0·619. No differences were noted in skin temperature measured with an infrared thermometer within and between the groups; mean difference between the groups was -0·17°C, P = 0·540. Cryotherapy did not improve skin blood flow or temperature and did not show efficacy in preventing ulcers. However, at least 30% of intervention and 50% of control participants were anticipated to develop an ulcer during the study; only ∼7% occurred. These findings suggest that strict adherence to standard of care decreases the incidence of leg ulcers and remains a best practice for leg ulcer prevention. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  15. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    PubMed

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  16. A new veno-venous bypass type for ex-vivo liver resection in dogs.

    PubMed

    Lei, Peng; Liu, Shi-Qi; Cui, Xiao-Hai; Lv, Yi; Zhao, Ge; Li, Jian-Hui

    2013-08-01

    Ex-vivo liver resection is a procedure in which the liver is completely removed, perfused and after bench surgery, the liver is autotransplanted to the original site. Ex-vivo liver resection is an important treatment for unresectable liver tumors. This surgical procedure requires long operation time, during which blood flow must be carefully maintained to avoid venous congestion. An effective veno-venous bypass (VVB) may meet this requirement. The present study was to test our new designed VVB device which comprised one heparinized polyvinylchloride tube and three magnetic rings. The efficacy of this device was tested in five dogs. A VVB was established in 6-10 minutes. There was no leakage during the procedure. Hemodynamics was stable at anhepatic phase, which indicated that the bypass was successful. This newly-developed VVB device maintained circulation stability during ex-vivo liver resection in our dog model and thus, this VVB device significantly shortened the operation time.

  17. To shunt or not to shunt? An experimental study comparing temporary vascular shunts and venous ligation as damage control techniques for vascular trauma.

    PubMed

    Marinho de Oliveira Góes Junior, Adenauer; de Campos Vieira Abib, Simone; de Seixas Alves, Maria Teresa; Venerando da Silva Ferreira, Paulo Sérgio; Carvalho de Andrade, Mariseth

    2014-04-01

    To evaluate vascular flow through temporary vascular shunts inserted into peripheral arteries and veins and the repercussion, on the arterial perfusion, of venous ligation and venous shunt insertion in an experimental model for damage control. Experimental study in pigs. Animals were distributed in 5 groups: group 1, right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2, right EIA shunting and right EIV shunting; group 3, right EIV ligation; group 4, right EIV shunting; group 5, no vascular shunting and no venous ligation. Flowmeters were used to measure vascular flow on right and left external iliac vessels, and blood samples were collected from the EIVs for biochemical analysis. A right anterior limb biopsy was performed before shock. Hemorrhagic shock was induced through the external right jugular vein, until the vascular flow through right iliac external artery shunt or right iliac external vein shunt (group 4) ceased or until the animal's death. After the end of the experiments, biopsies of bilateral hind limb were obtained for histologic analysis. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. In the absence of hemorrhagic shock, venous ligation (group 1) was associated with a 38.8% reduction (P < 0.05) and venous shunting with a 28.4% reduction on the vascular flow through the arterial shunt. When associated with hemorrhagic shock, the mean vascular flow on the right EIA was 13 mL/min and on the left EIA was 41.2 mL/min; on group 2, the right EIA flow was 8.5 mL/min and the left EIA flow was 8.1 mL/min. When associated with hemorrhagic shock, the pO2 was 25.8 mm Hg on right EIV and 33.8 mm Hg on the left EIV for group 1 (P < 0.05), whereas for group 2, the pO2 was 22.6 mm Hg on right EIV and 22.8 mm Hg on the left EIV. On group 1, serum potassium was 3.84 mEq/L on the right EIV and 3.96 mEq/L on the left EIV, whereas on group 2, it was 7.1 mEq/L on the right EIV and 5.88 m

  18. Venous thromboembolism prophylaxis in gynecologic surgery: a systematic review.

    PubMed

    Rahn, David D; Mamik, Mamta M; Sanses, Tatiana V D; Matteson, Kristen A; Aschkenazi, Sarit O; Washington, Blair B; Steinberg, Adam C; Harvie, Heidi S; Lukban, James C; Uhlig, Katrin; Balk, Ethan M; Sung, Vivian W

    2011-11-01

    To comprehensively review and critically assess the available gynecologic surgery venous thromboembolism prophylaxis literature and provide clinical practice guidelines. MEDLINE and Cochrane databases from inception to July 2010. We included randomized controlled trials in gynecologic surgery populations. Interventions and comparators included graduated compression stockings, intermittent pneumatic compression, unfractionated heparin, and low molecular weight heparin; placebo and routine postoperative care were allowed as comparators. One thousand two hundred sixty-six articles were screened, and 14 randomized controlled trials (five benign gynecologic, nine gynecologic oncology) met eligibility criteria. In addition, nine prospective or retrospective studies with at least 150 women were identified and provided data on venous thromboembolism risk stratification, gynecologic laparoscopy, and urogynecologic populations. Two reviewers independently screened articles with discrepancies adjudicated by a third. Eligible randomized controlled trials were extracted for these characteristics: study, participant, surgery, intervention, comparator, and outcomes data, including venous thromboembolism incidence and bleeding complications. Studies were individually and collectively assessed for methodologic quality and strength of evidence. Overall incidence of clinical venous thromboembolism was 0-2% in the benign gynecologic population. With use of intermittent pneumatic compression for benign major procedures, venous thromboembolism incidence was less than 1%. No venous thromboembolisms were identified in prospective studies of benign laparoscopic procedures. Overall quality of evidence in the benign gynecologic literature was poor. Gynecologic-oncology randomized controlled trials reported venous thromboembolism incidence (including "silent" venous thromboembolisms) of 0-14.8% with prophylaxis and up to 34.6% without prophylaxis. Fair quality of evidence supports that

  19. Classification of the venous architecture of the pineal gland by 7T MRI.

    PubMed

    Cho, Zang-Hee; Choi, Sang-Han; Chi, Je-Gun; Kim, Young-Bo

    2011-10-01

    Magnetic resonance imaging (MRI) at 7.0 Tesla (7T) can show many details of anatomical structures with unprecedented resolution and contrast. In this report, we describe for the first time the unexpected wide variation in pineal gland structure, as visualized by MR images obtained with 7T in a group of healthy young volunteers. A total of 34 volunteers (22 men and 12 women) were enrolled in the study. Their 7T MR images revealed such wide variations in pineal gland shape that it led us to attempt to classify the patterns seen in these pineal glands. Indeed, they were successfully correlated with a previous human cadaver study of venous structures by Tamaki et al., who classified the venous structures of the pineal gland into three categories. This is the first human in vivo pineal vein imaging study using 7T MRI. Pineal venous imaging may permit the early diagnosis of a pineal tumor. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  20. New, Virtually Wall-less Cannulas Designed for Augmented Venous Drainage in Minimally Invasive Cardiac Surgery.

    PubMed

    von Segesser, Ludwig Karl; Berdajs, Denis; Abdel-Sayed, Saad; Tozzi, Piergiorgio; Ferrari, Enrico; Maisano, Francesco

    2016-01-01

    Inadequate venous drainage during minimally invasive cardiac surgery becomes most evident when the blood trapped in the pulmonary circulation floods the surgical field. The present study was designed to assess the in vivo performance of new, thinner, virtually wall-less, venous cannulas designed for augmented venous drainage in comparison to traditional thin-wall cannulas. Remote cannulation was realized in 5 bovine experiments (74.0 ± 2.4 kg) with percutaneous venous access over the wire, serial dilation up to 18 F and insertion of either traditional 19 F thin wall, wire-wound cannulas, or through the same access channel, new, thinner, virtually wall-less, braided cannulas designed for augmented venous drainage. A standard minimal extracorporeal circuit set with a centrifugal pump and a hollow fiber membrane oxygenator, but no in-line reservoir was used. One hundred fifty pairs of pump-flow and required pump inlet pressure values were recorded with calibrated pressure transducers and a flowmeter calibrated by a volumetric tank and timer at increasing pump speed from 1500 RPM to 3500 RPM (500-RPM increments). Pump flow accounted for 1.73 ± 0.85 l/min for wall-less versus 1.17 ± 0.45 l/min for thin wall at 1500 RPM, 3.91 ± 0.86 versus 3.23 ± 0.66 at 2500 RPM, 5.82 ± 1.05 versus 4.96 ± 0.81 at 3500 RPM. Pump inlet pressure accounted for 9.6 ± 9.7 mm Hg versus 4.2 ± 18.8 mm Hg for 1500 RPM, -42.4 ± 26.7 versus -123 ± 51.1 at 2500 RPM, and -126.7 ± 55.3 versus -313 ± 116.7 for 3500 RPM. At the well-accepted pump inlet pressure of -80 mm Hg, the new, thinner, virtually wall-less, braided cannulas provide unmatched venous drainage in vivo. Early clinical analyses have confirmed these findings.

  1. A field trial of a PCR-based Mansonella ozzardi diagnosis assay detects high-levels of submicroscopic M. ozzardi infections in both venous blood samples and FTA card dried blood spots.

    PubMed

    Medeiros, Jansen Fernandes; Almeida, Tatiana Amaral Pires; Silva, Lucyane Bastos Tavares; Rubio, Jose Miguel; Crainey, James Lee; Pessoa, Felipe Arley Costa; Luz, Sergio Luiz Bessa

    2015-05-20

    Mansonella ozzardi is a poorly understood human filarial parasite with a broad distribution throughout Latin America. Most of what is known about its parasitism has come from epidemiological studies that have estimated parasite incidence using light microscopy. Light microscopy can, however, miss lighter, submicroscopic, infections. In this study we have compared M. ozzardi incidence estimates made using light microscopy, with estimates made using PCR. 214 DNA extracts made from Large Volume Venous Blood Samples (LVVBS) were taken from volunteers from two study sites in the Rio Solimões region: Codajás [n = 109] and Tefé [n = 105] and were subsequently assayed for M. ozzardi parasitism using a diagnostic PCR (Mo-dPCR). Peripheral finger-prick blood samples were taken from the same individuals and used for microscopic examination. Finger-prick blood, taken from individuals from Tefé, was also used for the creation of FTAcard dried blood spots (DBS) that were subsequently subjected to Mo-dPCR. Overall M. ozzardi incidence estimates made with LVVBS PCRs were 1.8 times higher than those made using microscopy (44.9% [96/214] compared with 24.3% [52/214]) and 1.5 times higher than the PCR estimates made from FTAcard DBS (48/105 versus 31/105). PCR-based detection of FTAcard DBS proved 1.3 times more sensitive at diagnosing infections from peripheral blood samples than light microscopy did: detecting 24/105 compared with 31/105. PCR of LVVBS reported the fewest number of false negatives, detecting: 44 of 52 (84.6%) individuals diagnosed by microscopy; 27 of 31 (87.1%) of those diagnosed positive from DBSs and 17 out of 18 (94.4%) of those diagnosed as positive by both alternative methodologies. In this study, Mo-dPCR of LVVBS was by far the most sensitive method of detecting M. ozzardi infections and detected submicroscopic infections. Mo-dPCR FTAcard DBS also provided a more sensitive test for M. ozzardi diagnosis than light microscopy based diagnosis did and

  2. Mass Spectrometry Method to Measure Membrane Proteins in Dried Blood Spots for the Detection of Blood Doping Practices in Sport.

    PubMed

    Cox, Holly D; Eichner, Daniel

    2017-09-19

    The dried blood spot (DBS) matrix has significant utility for applications in the field where venous blood collection and timely shipment of labile blood samples is difficult. Unfortunately, protein measurement in DBS is hindered by high abundance proteins and matrix interference that increases with hematocrit. We developed a DBS method to enrich for membrane proteins and remove soluble proteins and matrix interference. Following a wash in a series of buffers, the membrane proteins are digested with trypsin and quantitated by parallel reaction monitoring mass spectrometry methods. The DBS method was applied to the quantification of four cell-specific cluster of differentiation (CD) proteins used to count cells by flow cytometry, band 3 (CD233), CD71, CD45, and CD41. We demonstrate that the DBS method counts low abundance cell types such as immature reticulocytes as well as high abundance cell types such as red blood cells, white blood cells, and platelets. When tested in 82 individuals, counts obtained by the DBS method demonstrated good agreement with flow cytometry and automated hematology analyzers. Importantly, the method allows longitudinal monitoring of CD protein concentration and calculation of interindividual variation which is difficult by other methods. Interindividual variation of band 3 and CD45 was low, 6 and 8%, respectively, while variation of CD41 and CD71 was higher, 18 and 78%, respectively. Longitudinal measurement of CD71 concentration in DBS over an 8-week period demonstrated intraindividual variation 17.1-38.7%. Thus, the method may allow stable longitudinal measurement of blood parameters currently monitored to detect blood doping practices.

  3. Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle

    NASA Astrophysics Data System (ADS)

    Gurley, Katelyn; Shang, Yu; Yu, Guoqiang

    2012-07-01

    This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (\\Vdot O2) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and \\Vdot O2 in forearm flexor muscles, while a hybrid optical probe on the skin surface directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and THC), tissue oxygen saturation (StO2), relative BF (rBF), and relative oxygen consumption rate (r\\Vdot O2). The rBF and r\\Vdot O2 signals were calibrated with absolute baseline BF and \\Vdot O2 obtained through venous and arterial occlusions, respectively. Known problems with muscle-fiber motion artifacts in optical measurements during exercise were mitigated using a novel gating algorithm that determined muscle contraction status based on control signals from a dynamometer. Results were consistent with previous findings in the literature. This study supports the application of NIRS/DCS technology to quantitatively evaluate hemodynamic and metabolic parameters in exercising skeletal muscle and holds promise for improving diagnosis and treatment evaluation for patients suffering from diseases affecting skeletal muscle and advancing fundamental understanding of muscle and exercise physiology.

  4. Noninvasive optical quantification of absolute blood flow, blood oxygenation, and oxygen consumption rate in exercising skeletal muscle

    PubMed Central

    Gurley, Katelyn; Shang, Yu

    2012-01-01

    Abstract. This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (V˙O2) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and V˙O2 in forearm flexor muscles, while a hybrid optical probe on the skin surface directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and THC), tissue oxygen saturation (StO2), relative BF (rBF), and relative oxygen consumption rate (rV˙O2). The rBF and rV˙O2 signals were calibrated with absolute baseline BF and V˙O2 obtained through venous and arterial occlusions, respectively. Known problems with muscle-fiber motion artifacts in optical measurements during exercise were mitigated using a novel gating algorithm that determined muscle contraction status based on control signals from a dynamometer. Results were consistent with previous findings in the literature. This study supports the application of NIRS/DCS technology to quantitatively evaluate hemodynamic and metabolic parameters in exercising skeletal muscle and holds promise for improving diagnosis and treatment evaluation for patients suffering from diseases affecting skeletal muscle and advancing fundamental understanding of muscle and exercise physiology. PMID:22894482

  5. Vascular patterns in the heads of crocodilians: blood vessels and sites of thermal exchange.

    PubMed

    Porter, William Ruger; Sedlmayr, Jayc C; Witmer, Lawrence M

    2016-12-01

    Extant crocodilians are a highly apomorphic archosaur clade that is ectothermic, yet often achieve large body sizes that can be subject to higher heat loads. Therefore, the anatomical and physiological roles that blood vessels play in crocodilian thermoregulation need further investigation to better understand how crocodilians establish and maintain cephalic temperatures and regulate neurosensory tissue temperatures during basking and normal activities. The cephalic vascular anatomy of extant crocodilians, particularly American alligator (Alligator mississippiensis) was investigated using a differential-contrast, dual-vascular injection technique and high resolution X-ray micro-computed tomography (μCT). Blood vessels were digitally isolated to create representations of vascular pathways. The specimens were then dissected to confirm CT results. Sites of thermal exchange, consisting of the oral, nasal, and orbital regions, were given special attention due to their role in evaporative cooling and cephalic thermoregulation in other diapsids. Blood vessels to and from sites of thermal exchange were studied to detect conserved vascular patterns and to assess their ability to deliver cooled blood to neurosensory tissues. Within the orbital region, both the arteries and veins demonstrated consistent branching patterns, with the supraorbital, infraorbital, and ophthalmotemporal vessels supplying and draining the orbit. The venous drainage of the orbital region showed connections to the dural sinuses via the orbital veins and cavernous sinus. The palatal region demonstrated a vast plexus that comprised both arteries and veins. The most direct route of venous drainage of the palatal plexus was through the palatomaxillary veins, essentially bypassing neurosensory tissues. Anastomotic connections with the nasal region, however, may provide an alternative route for palatal venous blood to reach neurosensory tissues. The nasal region in crocodilians is probably the most

  6. Reactivity of retinal blood flow to 100% oxygen breathing after lipopolysaccharide administration in healthy subjects.

    PubMed

    Kolodjaschna, Julia; Berisha, Fatmire; Lasta, Michael; Polska, Elzbieta; Fuchsjäger-Mayrl, Gabriele; Schmetterer, Leopold

    2008-08-01

    Administration of low doses of Escherichia coli endotoxin (LPS) to humans enables the study of inflammatory mechanisms. The purpose of the present study was to investigate the retinal vascular reactivity after LPS infusion. In a randomized placebo-controlled cross-over study, 18 healthy male volunteers received 20 IU/kg LPS or placebo as an intravenous bolus infusion. Outcome parameters were measured at baseline and 4h after LPS/placebo administration. At baseline and at 4h after administration a short period of 100% oxygen inhalation was used to assess retinal vasoreactivity to this stimulus. Perimacular white blood cell velocity, density and flux were assessed with the blue-field entoptic technique, retinal branch arterial and venous diameters were measured with a retinal vessel analyzer and red blood cell velocity in retinal branch veins was measured with laser Doppler velocimetry. LPS is associated with peripheral blood leukocytosis and increased white blood cell density in ocular microvessels (p<0.001). In addition, retinal arterial (p=0.02) and venous (p<0.01) diameters were increased. All retinal hemodynamic parameters showed a decrease during 100% oxygen breathing. This decrease was significantly blunted by LPS for all retinal outcome parameters except venous diameter (p=0.04 for white blood cell velocity, p=0.0002 for white blood cell density, p<0.0001 for white blood cell flux, p=0.01 for arterial diameter, p=0.02 for red blood cell velocity and p=0.006 for red blood cell flux). These data indicate that LPS-induced inflammation induces vascular dysregulation in the retina. This may provide a link between inflammation and vascular dysregulation. Further studies are warranted to investigate whether this model may be suitable to study inflammation induced vascular dysregulation in the eye.

  7. Systemic Venous Inflow to the Liver Allograft to Overcome Diffuse Splanchnic Venous Thrombosis

    PubMed Central

    Darius, Tom; Goffette, Pierre; Lerut, Jan

    2015-01-01

    Diffuse splanchnic venous thrombosis (DSVT), formerly defined as contraindication for liver transplantation (LT), is a serious challenge to the liver transplant surgeon. Portal vein arterialisation, cavoportal hemitransposition and renoportal anastomosis, and finally combined liver and small bowel transplantation are all possible alternatives to deal with this condition. Five patients with preoperatively confirmed extensive splanchnic venous thrombosis were transplanted using cavoportal hemitransposition (4x) and renoportal anastomosis (1x). Median follow-up was 58 months (range: 0,5 to 130 months). Two patients with previous radiation-induced peritoneal injury died, respectively, 18 days and 2 months after transplantation. The three other patients had excellent long-term survival, despite the fact that two of them needed a surgical reintervention for severe gastrointestinal bleeding. Extensive splanchnic venous thrombosis is no longer an absolute contraindication to liver transplantation. Although cavoportal hemitransposition and renoportal anastomosis undoubtedly are life-saving procedures allowing for ensuring adequate allograft portal flow, careful follow-up of these patients remains necessary as both methods are unable to completely eliminate the complications of (segmental) portal hypertension. PMID:26539214

  8. A Case of Left Renal Vein Ligation in a Patient with Solitary Left Kidney Undergoing Liver Transplantation to Control Splenorenal Shunt and Improve Portal Venous Flow.

    PubMed

    Martino, Rodrigo B; Júnior, Eserval Rocha; Manuel, Valdano; Rocha-Santos, Vinicius; D'Albuquerque, Luis Augusto C; Andraus, Wellington

    2017-10-11

    BACKGROUND Adequate portal venous flow is required for successful liver transplantation. Reduced venous flow and blood flow 'steal' by collateral vessels are a concern, and when there is a prominent splenorenal shunt present, ligation of the left renal vein has been recommended to improve portal venous blood flow. CASE REPORT A 51-year-old man who had undergone right nephrectomy in childhood required liver transplantation for liver cirrhosis and hepatocellular carcinoma due to hepatitis C virus (HCV) infection. The patient had no other comorbidity and no history of hepatorenal syndrome. At transplantation surgery, portal venous flow was poor and did not improve with ligation of shunt veins, but ligation of the left renal vein improved portal venous flow. On the first and fifth postoperative days, the patient was treated with basiliximab, a chimeric monoclonal antibody to the IL-2 receptor, and methylprednisolone. The calcineurin inhibitor, tacrolimus, was introduced on the fifth postoperative day. On the sixteenth postoperative day, renal color Doppler ultrasound showed normal left renal parenchyma; hepatic Doppler ultrasound showed good portal vein flow and preserved hepatic parenchyma in the liver transplant. CONCLUSIONS This case report has shown that in a patient with a single left kidney, left renal vein ligation is feasible and safe in a patient with no other risk factors for renal impairment following liver transplantation. Modification of postoperative immunosuppression to avoid calcineurin inhibitors in the very early postoperative phase may be important in promoting good recovery of renal function and to avoid the need for postoperative renal dialysis.

  9. Intravascular thrombosis as a result of central venous access.

    PubMed

    Biernacka, Jadwiga; Nestorowicz, Andrzej; Wach, Małgorzata

    2002-01-01

    Central venous access represents one of the most basic therapeutic procedures in modern medicine. Unfortunately, numerous advantages that result from maintaining a central venous line are accompanied by some complications among which the venous thrombosis is the most significant clinically. The study was designed to assess frequency and natural history of this complication in the setting at a multi profile clinical hospital. Central venous cannulation was performed by a fully qualified anaesthesiologist in every case. There were 887 cannulations and only 5 patients with clinically significant venous thrombosis. The analysis of the collected data allowed us to state that the frequency of intravascular thrombosis is low, but this complication is often associated with extensive impairment of patency of the central veins. Full recanalization is not always achieved regardless of the treatment applied. Pulmonary embolism in the course of central venous thrombosis was diagnosed in one patient only and appeared as a multiple and fine X-ray infiltrates. It seems that in the presence of permanent or even life threatening complications of central venous thrombosis their risk should be minimized by frequent examination of the cannulation site and early initiation of antithrombotic treatment.

  10. Surgical model pig ex vivo for venous dissection teaching in medical schools.

    PubMed

    Tube, Milton Ignacio Carvalho; Spencer-Netto, Fernando Antonio Campelo; Oliveira, Anderson Igor Pereira de; Holanda, Arthur Cesário de; Barros, Bruno Leão Dos Santos; Rezende, Caio Cezar Gomes; Cavalcanti, João Pedro Guerra; Batista, Marília Apolinário; Campos, Josemberg Marins

    2017-02-01

    To investigate a method for development of surgical skills in medical students simulating venous dissection in surgical ex vivo pig model. Prospective, analytical, experimental, controlled study with four stages: selection, theoretical teaching, training and assessment. Sample of 312 students was divided into two groups: Group A - 2nd semester students; Group B - students of 8th semester. The groups were divided into five groups of 12 students, trained two hours per week in the semester. They set up four models to three students in each skill station assisted by a monitor. Teaching protocol emergency procedures training were applied to venous dissection, test goal-discursive and OSATS scale. The pre-test confirmed that the methodology has not been previously applied to the students. The averages obtained in the theoretical evaluation reached satisfactory parameters in both groups. The results of applying OSATS scale showed the best performance in group A compared to group B, however, both groups had satisfactory medium. The method was enough to raise a satisfactory level of skill both groups in venous dissection running on surgical swine ex vivo models.

  11. Modelling Cerebral Blood Flow and Temperature Using a Vascular Porous Model

    NASA Astrophysics Data System (ADS)

    Blowers, Stephen; Thrippleton, Michael; Marshall, Ian; Harris, Bridget; Andrews, Peter; Valluri, Prashant

    2016-11-01

    Macro-modelling of cerebral blood flow can assist in determining the impact of temperature intervention to reduce permanent tissue damage during instances of brain trauma. Here we present a 3D two phase fluid-porous model for simulating blood flow through the capillary region linked to intersecting 1D arterial and venous vessel trees. This combined vasculature porous (VaPor) model simulates both flow and energy balances, including heat from metabolism, using a vasculature extracted from MRI data which are expanded upon using a tree generation algorithm. Validation of temperature balance has been achieved using rodent brain data. Direct flow validation is not as straight forward due to the method used in determining regional cerebral blood flow (rCBF). In-vivo measurements are achieved using a tracer, which disagree with direct measurements of simulated flow. However, by modelling a virtual tracer, rCBF values are obtained that agree with those found in literature. Temperature profiles generated with the VaPor model show a reduction in core brain temperature after cooling the scalp not seen previously in other models.

  12. Imaging of head and neck venous malformations.

    PubMed

    Flis, Christine M; Connor, Stephen E

    2005-10-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team.

  13. Cost-effectiveness of wound management in France: pressure ulcers and venous leg ulcers.

    PubMed

    Meaume, S; Gemmen, E

    2002-06-01

    This study set out to define realistic protocols of care for the treatment of chronic venous leg ulcers and pressure ulcers in France and, by developing cost-effectiveness models, to compare the different protocols of care for the two ulcer groups, enabling a calculation of direct medical costs per ulcer healed in a typical French health insurance plan. Clinical outcomes and some treatment patterns were obtained from published literature. Validations of different treatment patterns were developed using an expert consensus panel similar to the Delphi approach. Costs were calculated based on national averages and estimates from the UK and Germany. The models were used to measure costs per healed ulcer over a 12-week period. For both the pressure ulcer and venous leg ulcer models, three protocols of care were identified. For pressure ulcers and venous leg ulcers, the hydrocolloid DuoDERM (ConvaTec, also known as Granuflex in the UK and Varihesive in Germany) was most cost-effective in France. The combination of published data and expert consensus opinion is a valid technique, and in this case suggests that treating pressure ulcers and venous leg ulcers with hydrocolloid dressings is more cost-effective than treating them with saline gauze, in spite of the lower unit cost of the latter.

  14. Cardiovascular Pressures with Venous Gas Embolism and Decompression

    NASA Technical Reports Server (NTRS)

    Butler, B. D.; Robinson, R.; Sutton, T.; Kemper, G. B.

    1995-01-01

    Venous gas embolism (VGE) is reported with decompression to a decreased ambient pressure. With severe decompression, or in cases where an intracardiac septal defect (patent foramen ovale) exists, the venous bubbles can become arterialized and cause neurological decompression illness. Incidence rates of patent foramen ovale in the general population range from 25-34% and yet aviators, astronauts, and deepsea divers who have decompression-induced venous bubbles do not demonstrate neurological symptoms at these high rates. This apparent disparity may be attributable to the normal pressure gradient across the atria of the heart that must be reversed for there to be flow potency. We evaluated the effects of: venous gas embolism (0.025, 0.05 and 0.15 ml/ kg min for 180 min.) hyperbaric decompression; and hypobaric decompression on the pressure gradient across the left and right atria in anesthetized dogs with intact atrial septa. Left ventricular end-diastolic pressure was used as a measure of left atrial pressure. In a total of 92 experimental evaluations in 22 dogs, there were no reported reversals in the mean pressure gradient across the atria; a total of 3 transient reversals occurred during the peak pressure gradient changes. The reasons that decompression-induced venous bubbles do not consistently cause serious symptoms of decompression illness may be that the amount of venous gas does not always cause sufficient pressure reversal across a patent foramen ovale to cause arterialization of the venous bubbles.

  15. Core content for training in venous and lymphatic medicine.

    PubMed

    Zimmet, Steven E; Min, Robert J; Comerota, Anthony J; Meissner, Mark H; Carman, Teresa L; Rathbun, Suman W; Jaff, Michael R; Wakefield, Thomas W; Feied, Craig F

    2014-10-01

    The major venous societies in the United States share a common mission to improve the standards of medical practitioners, the educational goals for teaching and training programs in venous disease, and the quality of patient care related to the treatment of venous disorders. With these important goals in mind, a task force made up of experts from the specialties of dermatology, interventional radiology, phlebology, vascular medicine, and vascular surgery was formed to develop a consensus document describing the Core Content for venous and lymphatic medicine and to develop a core educational content outline for training. This outline describes the areas of knowledge considered essential for practice in the field, which encompasses the study, diagnosis, and treatment of patients with acute and chronic venous and lymphatic disorders. The American Venous Forum and the American College of Phlebology have endorsed the Core Content. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Measurement of venous compliance (8-IML-1)

    NASA Technical Reports Server (NTRS)

    Thirsk, R. B.

    1992-01-01

    The prime objective of this International Microgravity Laboratory (IML-1) investigation is to measure the bulk compliance (distensibility) of the veins in the lower leg before, during, and after spaceflight. It is of particular interest whether venous compliance over the range of both positive and negative transmural pressures (various states of venous distention and collapse) changes throughout the duration of spaceflight. Information concerning the occurrence and character of compliance changes could have implications for the design of improved antigravity suits and further the understanding of inflight and postflight venous hemodynamics.

  17. Duplex imaging of residual venous obstruction to guide duration of therapy for lower extremity deep venous thrombosis.

    PubMed

    Stephenson, Elliot J P; Liem, Timothy K

    2015-07-01

    Clinical trials have shown that the presence of ultrasound-identified residual venous obstruction (RVO) on follow-up scanning may be associated with an elevated risk for recurrence, thus providing a potential tool to help determine the optimal duration of anticoagulant therapy. We performed a systematic review to evaluate the clinical utility of post-treatment duplex imaging in predicting venous thromboembolism (VTE) recurrence and in adjusting duration of anticoagulation. The Ovid MEDLINE Database, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Database of Abstracts of Reviews of Effects were queried for the terms residual thrombus or obstruction, duration of therapy, deep vein thrombosis, deep venous thrombosis, DVT, venous thromboembolism, VTE, antithrombotic therapy, and anticoagulation, and 228 studies were selected for review. Six studies determined the rate of VTE recurrence on the basis of the presence or absence of RVO. Findings on venous ultrasound scans frequently remained abnormal in 38% to 80% of patients, despite at least 3 months of therapeutic anticoagulation. In evaluating for VTE recurrence, the definition of RVO varied widely in the literature. Some studies have shown an association between RVO and VTE recurrence, whereas other studies have not. Overall, the presence of RVO is a mild risk factor for recurrence (odds ratio, 1.3-2.0), but only when surveillance imaging is performed soon after the index deep venous thrombosis (3 months). RVO is a mild risk factor for VTE recurrence. The presence or absence of ultrasound-identified RVO has a limited role in guiding the duration of therapeutic anticoagulation. Further research is needed to evaluate its utility relative to other known risk factors for VTE recurrence. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. The efficacy of the new SCD response compression system in the prevention of venous stasis.

    PubMed

    Kakkos, S K; Szendro, G; Griffin, M; Daskalopoulou, S S; Nicolaides, A N

    2000-11-01

    The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds' compression and 60 seconds' deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean +/- SD) in the sitting position was 40.6 +/- 10. 0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 +/- 4.1 and 35.6 +/- 4.9 seconds, respectively. There was a linear relationship between the duplex scan-derived refill time (mean of 6 readings per leg) and the SCD Response device

  19. Use of peripherally inserted central venous catheters (PICCs) in children receiving autologous or allogeneic stem-cell transplantation.

    PubMed

    Benvenuti, Stefano; Ceresoli, Rosanna; Boroni, Giovanni; Parolini, Filippo; Porta, Fulvio; Alberti, Daniele

    2018-03-01

    The aim of our study was to present our experience with the use of peripherally inserted central catheters (PICCs) in pediatric patients receiving autologous or allogenic blood stem-cell transplantation. The insertion of the device in older children does not require general anesthesia and does not require a surgical procedure. From January 2014 to January 2017, 13 PICCs were inserted as a central venous device in 11 pediatric patients submitted to 14 autologous or allogeneic stem-cell transplantation, at the Bone Marrow Transplant Unit of the Children's Hospital of Brescia. The mean age of patients at the time of the procedure was 11.3 years (range 3-18 years). PICCs remained in place for an overall period of 4104 days. All PICCs were positioned by the same specifically trained physician and utilized by nurses of our stem-cell transplant unit. No insertion-related complications were observed. Late complications were catheter ruptures and line occlusions (1.2 per 1000 PICC days). No rupture or occlusion required removal of the device. No catheter-related venous thrombosis, catheter-related bloodstream infection (CRBSI), accidental removal or permanent lumen occlusion were observed. Indications for catheter removal were completion of therapy (8 patients) and death (2 patients). Three PICCs are currently being used for blood sampling in follow-up patients after transplantation. Our data suggest that PICCs are a safe and effective alternative to conventional central venous catheters even in pediatric patients with high risk of infectious and hemorrhagic complications such as patients receiving stem-cell transplantation.

  20. Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site.

    PubMed

    Richards, N A; Boyce, H; Yentis, S M

    2010-01-01

    Haemoglobin concentration measured using the HemoCue is accurate for capillary and venous/arterial blood, provided the recommended sampling method is strictly observed. Analysis of blood, particularly of capillary samples, using the HemoCue is useful during caesarean section. The toe might be preferred to the thumb since it is numb during neuraxial anaesthesia, but whether sampling at either site is accurate in this situation, given the cardiovascular effects of anaesthesia and pregnancy, is not known. We aimed to compare haemoglobin values measured in venous and capillary samples (toe and thumb) during caesarean section under neuraxial anaesthesia. Fifty healthy women having caesarean section under spinal or combined spinal-epidural anaesthesia were included. At the end of surgery, the great toe and thumb (non-i.v. fluid side) were lanced as recommended for a HemoCue reading. A venous blood sample (non-i.v. fluid side) was also taken and sent for formal laboratory measurement and tested with the HemoCue. Bland-Altman analysis was applied to the haemoglobin values. Bias (mean difference) and precision +/- 2 SD were respectively 0.2 +/-1.6 for laboratory vs. toe, 0.1 +/-1.8 for laboratory vs. thumb, and 0.2 +/-1.6 laboratory vs. venous. Our results suggest that in terms of accuracy, the two sites are equally suitable for use during caesarean section under neuraxial anaesthesia. Copyright 2009 Elsevier Ltd. All rights reserved.

  1. Venous compression syndrome of internal jugular veins prevalence in patients with multiple sclerosis and chronic cerebro-spinal venous insufficiency.

    PubMed

    Mandolesi, Sandro; Niglio, Tarcisio; Orsini, Augusto; De Sio, Simone; d'Alessandro, Alessandro; Mandolesi, Dimitri; Fedele, Francesco; d'Alessandro, Aldo

    2016-01-01

    Analysis of the incidence of Venous Compression Syndrome (VCS) with full block of the flow of the internal jugular veins (IJVs) in patients with Multiple Sclerosis and Chronic cerebro-spinal venous insufficiency. We included 769 patients with MS and CCSVI (299 males, 470 females) and 210 controls without ms and ccsvi (92 males, 118 females). each subject was investigated by echo-color-doppler (ecd). morphological and hemodynamic ecd data were recorded by a computerized mem-net maps of epidemiological national observatory on ccsvi and they were analyzed by mem-net clinical analysis programs. VCS of IJVs occurs in 240 subjects affected by CCSVI and MS (31% of total) and in 12 controls (6% of total). The differences between the two groups are statistical significant (X² = 36.64, p<0.0001). Up to day there are no longitudinal studies that allow us to identify the WC of jugular and/or vertebral veins as etiology of a chronic neurodegenerative disease, but we note that Venous Compression Syndrome of IJVs is strongly associated with MS and CCSVI. Chronic Cerebro-Spinal Venous Insufficiency, Multiple Sclerosis, Venous Compression Syndrome.

  2. Lifetime Risk of Venous Thromboembolism in Two Cohort Studies.

    PubMed

    Bell, Elizabeth J; Lutsey, Pamela L; Basu, Saonli; Cushman, Mary; Heckbert, Susan R; Lloyd-Jones, Donald M; Folsom, Aaron R

    2016-03-01

    Greater public awareness of venous thromboembolism may be an important next step for optimizing venous thromboembolism prevention and treatment. "Lifetime risk" is an easily interpretable way of presenting risk information. Therefore, we sought to calculate the lifetime risk of venous thromboembolism (deep vein thrombosis or pulmonary embolism) using data from 2 large, prospective cohort studies: the Cardiovascular Health Study (CHS) and the Atherosclerosis Risk in Communities (ARIC) study. We followed participants aged 45-64 years in ARIC (n = 14,185) and ≥65 in CHS (n = 5414) at baseline visits (1987-1989 in ARIC, 1989-1990 and 1992-1993 in CHS) for incident venous thromboembolism (n = 728 in ARIC through 2011 and n = 172 in CHS through 2001). We estimated lifetime risks and 95% confidence intervals of incident venous thromboembolism using a modified Kaplan-Meier method, accounting for the competing risk of death from other causes. At age 45 years, the remaining lifetime risk of venous thromboembolism in ARIC was 8.1% (95% confidence interval, 7.1-8.7). High-risk groups were African Americans (11.5% lifetime risk), those with obesity (10.9%), heterozygous for the factor V Leiden (17.1%), or with sickle cell trait or disease (18.2%). Lifetime risk estimates differed by cohort; these differences were explained by differences in time period of venous thromboembolism ascertainment. At least 1 in 12 middle-aged adults will develop venous thromboembolism in their remaining lifetime. This estimate of lifetime risk may be useful to promote awareness of venous thromboembolism and guide decisions at both clinical and policy levels. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Using a Model of Clinical Events to Determine Supply Requirements for Marine Corps Shock Surgical Team/Triage (SST) and Acute Care Ward Units.

    DTIC Science & Technology

    1998-06-01

    Infusion Blood Products • 248 Force Fluids • • 064 Venous Cutdown • 263 Partial Bath (Assisted) • • 065 Insert Central Venous Lines • 267 Linen Change...which are further complicated by inadequate patient histories , diagnostic tools, and logistic support. Timely and appropriate treatment may...Appropriate Medication • 011 Stabilize Cervical • • 148 Obtain Specimen for Lab Analysis • • 017 Suction (Oral/Trach/Endo) • • 149 Blood Drawing Venous

  4. A Prospective, Randomized Trial of Intravenous Hydroxocobalamin Versus Whole Blood Transfusion Compared to No Treatment for Class III Hemorrhagic Shock Resuscitation in a Prehospital Swine Model

    DTIC Science & Technology

    2015-03-01

    statistically significant increase in systemic vascular resistance compared to control, but not whole blood, with a concomitant decrease in cardiac...increasing blood pressure as well as sys- temic vascular resistance in a hypovolemic hemorrhagic swine model.18 The primary hypothesis of this study is...output, sys- temic vascular resistance , mixed venous oxygen satura- tion, central venous pressure, pulmonary artery pressure, and core temperature. The

  5. Effect of venous stenting on intracranial pressure in idiopathic intracranial hypertension.

    PubMed

    Matloob, Samir A; Toma, Ahmed K; Thompson, Simon D; Gan, Chee L; Robertson, Fergus; Thorne, Lewis; Watkins, Laurence D

    2017-08-01

    Idiopathic intracranial hypertension (IIH) is characterised by an increased intracranial pressure (ICP) in the absence of any central nervous system disease or structural abnormality and by normal CSF composition. Management becomes complicated once surgical intervention is required. Venous sinus stenosis has been suggested as a possible aetiology for IIH. Venous sinus stenting has emerged as a possible interventional option. Evidence for venous sinus stenting is based on elimination of the venous pressure gradient and clinical response. There have been no studies demonstrating the immediate effect of venous stenting on ICP. Patients with a potential or already known diagnosis of IIH were investigated according to departmental protocol. ICP monitoring was performed for 24 h. When high pressures were confirmed, CT venogram and catheter venography were performed to look for venous stenosis to demonstrate a pressure gradient. If positive, venous stenting would be performed and ICP monitoring would continue for a further 24 h after deployment of the venous stent. Ten patients underwent venous sinus stenting with concomitant ICP monitoring. Nine out of ten patients displayed an immediate reduction in their ICP that was maintained at 24 h. The average reduction in mean ICP and pulsatility was significant (p = 0.003). Six out of ten patients reported a symptomatic improvement within the first 2 weeks. Venous sinus stenting results in an immediate reduction in ICP. This physiological response to venous stenting has not previously been reported. Venous stenting could offer an alternative treatment option in correctly selected patients with IIH.

  6. Effects of head down tilt on episcleral venous pressure in a rabbit model.

    PubMed

    Lavery, W J; Kiel, J W

    2013-06-01

    In humans, changing from upright to supine elicits an approximately 10 mmHg increase in cephalic venous pressure caused by the hydrostatic column effect, but episcleral venous pressure (EVP) and intraocular pressure (IOP) rise by only a few mmHg. The dissociation of the small increases in IOP and EVP compared to the larger increase in cephalic venous pressure suggests a regulatory mechanism controlling EVP. The aim of the present study was to determine if the rabbit model is suitable to study the effects of postural changes on EVP despite its short hydrostatic column. In anesthetized rabbits (n = 43), we measured arterial pressure (AP), IOP, and orbital venous pressure (OVP) by direct cannulation; carotid blood flow (BFcar) by transit time ultrasound, heart rate (HR) by digital cardiotachometer, and EVP with a servonull micropressure system. The goal of the protocol was to obtain measurement of supine EVP for ≈10 min, followed by ≈10 min of EVP measurement with the rabbit in a head down tilt. The data were analyzed by paired t-tests and the results reported as the mean ± standard error of the mean. In a separate group of animals (n = 35), aqueous flow was measured by fluorophotometry. This protocol entailed measurement of aqueous flow in the supine position for ≈60 min, followed by ≈60 min of aqueous flow measurement with the rabbit in a head down tilt. From supine to head down tilt, AP and BFcar were unchanged, IOP increased by 2.3 ± 0.4 mmHg (p < 0.001), EVP increased by 2.4 ± 0.4 mmHg (p < 0.001), OVP increased by 2.5 ± 0.2 mmHg (p < 0.001) and HR decreased by 9 ± 3 bpm (p = 0.002). Head down tilt caused no significant change in aqueous flow. Although the hydrostatic column in the rabbit is shorter than humans, the rabbit model permits sufficiently sensitive measurements of the pressures and systemic parameters likely involved in the EVP responses to posture change. The present results indicate directionally similar EVP and IOP responses to tilt as

  7. Delivery of compression therapy for venous leg ulcers.

    PubMed

    Zarchi, Kian; Jemec, Gregor B E

    2014-07-01

    Despite the documented effect of compression therapy in clinical studies and its widespread prescription, treatment of venous leg ulcers is often prolonged and recurrence rates high. Data on provided compression therapy are limited. To assess whether home care nurses achieve adequate subbandage pressure when treating patients with venous leg ulcers and the factors that predict the ability to achieve optimal pressure. We performed a cross-sectional study from March 1, 2011, through March 31, 2012, in home care centers in 2 Danish municipalities. Sixty-eight home care nurses who managed wounds in their everyday practice were included. Participant-masked measurements of subbandage pressure achieved with an elastic, long-stretch, single-component bandage; an inelastic, short-stretch, single-component bandage; and a multilayer, 2-component bandage, as well as, association between achievement of optimal pressure and years in the profession, attendance at wound care educational programs, previous work experience, and confidence in bandaging ability. A substantial variation in the exerted pressure was found: subbandage pressures ranged from 11 mm Hg exerted by an inelastic bandage to 80 mm Hg exerted by a 2-component bandage. The optimal subbandage pressure range, defined as 30 to 50 mm Hg, was achieved by 39 of 62 nurses (63%) applying the 2-component bandage, 28 of 68 nurses (41%) applying the elastic bandage, and 27 of 68 nurses (40%) applying the inelastic bandage. More than half the nurses applying the inelastic (38 [56%]) and elastic (36 [53%]) bandages obtained pressures less than 30 mm Hg. At best, only 17 of 62 nurses (27%) using the 2-component bandage achieved subbandage pressure within the range they aimed for. In this study, none of the investigated factors was associated with the ability to apply a bandage with optimal pressure. This study demonstrates the difficulty of achieving the desired subbandage pressure and indicates that a substantial proportion of

  8. Connective tissue-activating peptide III: a novel blood biomarker for early lung cancer detection.

    PubMed

    Yee, John; Sadar, Marianne D; Sin, Don D; Kuzyk, Michael; Xing, Li; Kondra, Jennifer; McWilliams, Annette; Man, S F Paul; Lam, Stephen

    2009-06-10

    There are no reliable blood biomarkers to detect early lung cancer. We used a novel strategy that allows discovery of differentially present proteins against a complex and variable background. Mass spectrometry analyses of paired pulmonary venous-radial arterial blood from 16 lung cancer patients were applied to identify plasma proteins potentially derived from the tumor microenvironment. Two differentially expressed proteins were confirmed in 64 paired venous-arterial blood samples using an immunoassay. Twenty-eight pre- and postsurgical resection peripheral blood samples and two independent, blinded sets of plasma from 149 participants in a lung cancer screening study (49 lung cancers and 100 controls) and 266 participants from the National Heart Lung and Blood Institute Lung Health Study (45 lung cancer and 221 matched controls) determined the accuracy of the two protein markers to detect subclinical lung cancer. Connective tissue-activating peptide III (CTAP III)/ neutrophil activating protein-2 (NAP-2) and haptoglobin were identified to be significantly higher in venous than in arterial blood. CTAP III/NAP-2 levels decreased after tumor resection (P = .01). In two independent population cohorts, CTAP III/NAP-2 was significantly associated with lung cancer and improved the accuracy of a lung cancer risk prediction model that included age, smoking, lung function (FEV(1)), and an interaction term between FEV(1) and CTAP III/NAP-2 (area under the curve, 0.84; 95% CI, 0.77 to 0.91) compared to CAPIII/NAP-2 alone. We identified CTAP III/NAP-2 as a novel biomarker to detect preclinical lung cancer. The study underscores the importance of applying blood biomarkers as part of a multimodal lung cancer risk prediction model instead of as stand-alone tests.

  9. System Design and Development of a Robotic Device for Automated Venipuncture and Diagnostic Blood Cell Analysis.

    PubMed

    Balter, Max L; Chen, Alvin I; Fromholtz, Alex; Gorshkov, Alex; Maguire, Tim J; Yarmush, Martin L

    2016-10-01

    Diagnostic blood testing is the most prevalent medical procedure performed in the world and forms the cornerstone of modern health care delivery. Yet blood tests are still predominantly carried out in centralized labs using large-volume samples acquired by manual venipuncture, and no end-to-end solution from blood draw to sample analysis exists today. Our group is developing a platform device that merges robotic phlebotomy with automated diagnostics to rapidly deliver patient information at the site of the blood draw. The system couples an image-guided venipuncture robot, designed to address the challenges of routine venous access, with a centrifuge-based blood analyzer to obtain quantitative measurements of hematology. In this paper, we first present the system design and architecture of the integrated device. We then perform a series of in vitro experiments to evaluate the cannulation accuracy of the system on blood vessel phantoms. Next, we assess the effects of vessel diameter, needle gauge, flow rate, and viscosity on the rate of sample collection. Finally, we demonstrate proof-of-concept of a white cell assay on the blood analyzer using in vitro human samples spiked with fluorescently labeled microbeads.

  10. [Dynamic determination of the medicine concentration of poisoned blood of acephate].

    PubMed

    Chu, Jian-Xin; Shen, Ju-Hua; Jiang, Wen-Hui

    2006-06-01

    To observe rule of medicine concentration of blood and the last concentration that through hemoperfusion after poisoned by acephate. Utilizeng the patient annual bonus venous blood in hospital emergency room, the content of acephate in plasma was analyzed by gas chromatography. After hemoperfusion, the concentration of acephate showed a rapid drop and the characteristic that the concentration drops quicker if medicine concentration of blood before hemoperfusion is higher. Hemoperfusion is able to rapidly reduce the concentration of acephate in blood, its speed is determined by initial concentration and the beginning time of hemoperfusion etc.

  11. Patterns and Rates of Supplementary Venous Drainage to the Internal Jugular Veins.

    PubMed

    Qureshi, Adnan I; Ishfaq, Muhammad Fawad; Herial, Nabeel A; Khan, Asif A; Suri, M Fareed K

    2016-07-01

    Several studies have found supplemental venous drainage channels in addition to bilateral internal jugular veins for cerebral venous efflux. We performed this study to characterize the supplemental venous outflow patterns in a consecutive series of patients undergoing detailed cerebral angiography with venous phase imaging. The venographic phase of the arteriogram was reviewed to identify and classify supplemental cerebral venous drainage into anterior (cavernous venous sinus draining into pterygoid plexus and retromandibular vein) and posterior drainage pattern. The posterior drainage pattern was further divided into plexiform pattern (with sigmoid venous sinus draining into the paravertebral venous plexus), and solitary vein pattern (dominant single draining deep cervical vein) drainage. The posterior plexiform pattern was further divided into 2 groups: posterior plexiform with or without prominent solitary vein. Supplemental venous drainage was seen ipsilateral to internal jugular vein in 76 (43.7%) of 174 venous drainages (87 patients) analyzed. The patterns were anterior (n = 23, 13.2%), posterior plexiform without prominent solitary vein (n = 40, 23%), posterior plexiform with prominent solitary vein (n = 62, 35.6%), and posterior solitary vein alone (n = 3, 1.7%); occipital emissary veins and/or transosseous veins were seen in 1 supplemental venous drainage. Concurrent ipsilateral anterior and posterior supplemental drainage was seen in 6 of 174 venous drainages analyzed. We provide an assessment of patterns and rates of supplementary venous drainage to internal jugular veins to improve our understanding of anatomical and physiological aspects of cerebral venous drainage. Copyright © 2016 by the American Society of Neuroimaging.

  12. The cumulative influence of hyperoxia and hypercapnia on blood oxygenation and R2*

    PubMed Central

    Faraco, Carlos C; Strother, Megan K; Siero, Jeroen CW; Arteaga, Daniel F; Scott, Allison O; Jordan, Lori C; Donahue, Manus J

    2015-01-01

    Cerebrovascular reactivity (CVR)-weighted blood-oxygenation-level-dependent magnetic resonance imaging (BOLD-MRI) experiments are frequently used in conjunction with hyperoxia. Owing to complex interactions between hyperoxia and hypercapnia, quantitative effects of these gas mixtures on BOLD responses, blood and tissue R2*, and blood oxygenation are incompletely understood. Here we performed BOLD imaging (3 T; TE/TR=35/2,000 ms; spatial resolution=3 × 3 × 3.5 mm3) in healthy volunteers (n=12; age=29±4.1 years) breathing (i) room air (RA), (ii) normocapnic–hyperoxia (95% O2/5% N2, HO), (iii) hypercapnic–normoxia (5% CO2/21% O2/74% N2, HC-NO), and (iv) hypercapnic–hyperoxia (5% CO2/95% O2, HC-HO). For HC-HO, experiments were performed with separate RA and HO baselines to control for changes in O2. T2-relaxation-under-spin-tagging MRI was used to calculate basal venous oxygenation. Signal changes were quantified and established hemodynamic models were applied to quantify vasoactive blood oxygenation, blood–water R2*, and tissue–water R2*. In the cortex, fractional BOLD changes (stimulus/baseline) were HO/RA=0.011±0.007; HC-NO/RA=0.014±0.004; HC-HO/HO=0.020±0.008; and HC-HO/RA=0.035±0.010; for the measured basal venous oxygenation level of 0.632, this led to venous blood oxygenation levels of 0.660 (HO), 0.665 (HC-NO), and 0.712 (HC-HO). Interleaving a HC-HO stimulus with HO baseline provided a smaller but significantly elevated BOLD response compared with a HC-NO stimulus. Results provide an outline for how blood oxygenation differs for several gas stimuli and provides quantitative information on how hypercapnic BOLD CVR and R2* are altered during hyperoxia. PMID:26174329

  13. Relative value of computed tomography scanning and venous sampling in establishing the cause of primary hyperaldosteronism.

    PubMed

    Sheaves, R; Goldin, J; Reznek, R H; Chew, S L; Dacie, J E; Lowe, D G; Ross, R J; Wass, J A; Besser, G M; Grossman, A B

    1996-03-01

    The purpose of this study was to evaluate the relative merits of the postural stimulation test, adrenal computed tomography (CT) and venous sampling in the differential diagnosis of patients presenting with primary hyperaldosteronism. The records of 20 patients presenting with primary hyperaldosteronism were reviewed retrospectively. There were 15 patients with a unilateral aldosterone-producing adenoma (APA), four patients with idiopathic hyperaldosteronism (IHA) and one patient with primary adrenal hyperplasia (PAH). The postural stimulation test was based on measurements of plasma aldosterone and renin activity at 08.00 h and at noon after 4 h of ambulation. The CT scans of the adrenals were reviewed by a single radiologist. Bilateral venous sampling of adrenal veins was attempted in all patients and blood collected for aldosterone and cortisol assay. Plasma aldosterone concentration increased after 4 h of standing in all cases of hyperplasia but was also demonstrated in 10/15 patients with a surgically-proven APA. If one defines a significant postural rise as being greater than 30%, then 8/15 patients with APA can be considered as being posturally responsive. Computed tomography scanning correctly identified all 15 cases of APA and also classified correctly the remaining five cases of hyperplasia (four cases of IHA and one case of PAH). Venous sampling failed technically in 4/15 cases of APA and in one case of IHA: a total of 5/20 (25%,). A correct diagnosis of APA or IHA was established in all the remaining cases. However, the one case of PAH was treated successfully by adrenalectomy following venous sampling, which suggested a unilateral adrenal lesion: this one result was the only instance where venous sampling altered clinical decision-making. Computed tomography scanning may be used alone to confirm the cause of hyperaldosteronism where postural studies suggest an adrenal adenoma, and such patients may be considered for early surgery. Venous

  14. Venous Return and Clinical Hemodynamics: How the Body Works during Acute Hemorrhage

    ERIC Educational Resources Information Center

    Shen, Tao; Baker, Keith

    2015-01-01

    Venous return is a major determinant of cardiac output. Adjustments within the venous system are critical for maintaining venous pressure during loss in circulating volume. This article reviews two factors that are thought to enable the venous system to compensate during acute hemorrhage: 1) changes in venous elastance and 2) mobilization of…

  15. Dried venous blood samples for the detection and quantification of measles IgG using a commercial enzyme immunoassay.

    PubMed Central

    Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.

    2003-01-01

    OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429

  16. Concurrent Angioplasty Balloon Placement for Stent Delivery through Jugular Venous Bulb for Treating Cerebral Venous Sinus Stenosis. Technical Report.

    PubMed

    Qureshi, Adnan I; Khan, Asif A; Capistrant, Rachel; Qureshi, Mushtaq H; Xie, Kevin; Suri, M Fareed K

    2016-10-01

    To report upon technique of concurrent placement of angioplasty balloon at the internal jugular vein and sigmoid venous sinus junction to facilitate stent delivery in two patients in whom stent delivery past the jugular bulb was not possible. A 21-year-old woman and a 41-year-old woman with worsening headaches, visual obscuration or diplopia were treated for pseudotumor cerebri associated with transverse venous stenosis. Both patients had undergone primary angioplasty, which resulted in improvement in clinical symptoms followed by the recurrence of symptoms with restenosis at the site of angioplasty. After multiple attempts at stent delivery through jugular venous bulb were unsuccessful, a second guide catheter was placed in the ipsilateral internal jugular vein through contralateral femoral venous approach. A 6 mm × 20 mm (left) or 5 × 15 mm (right) angioplasty balloon was placed across the internal jugular vein and sigmoid sinus junction and partially inflated until the inflation and relative straightening of the junction was observed. In both patients, the internal jugular vein and sigmoid sinus junction was successfully traversed by the stent delivery system in a parallel alignment to inflated balloon. Balloon mounted stent was deployed at the site of restenosis with near complete resolution of lumen narrowing delivery and improvement in clinical symptoms. We report a technique for realignment and diameter change with concurrent placement and partial inflation of angioplasty balloon at the jugular venous bulb to facilitate stent delivery into the sigmoid and transverse venous sinuses in circumstances where multiple attempts at stent delivery are unsuccessful.

  17. Potential substitution of cord blood for infant blood in the neonatal sepsis evaluation.

    PubMed

    Hansen, Anne; Forbes, Peter; Buck, Rosanne

    2005-01-01

    Evaluation of sepsis accounts for one third of all nursery triage admissions. If umbilical cord blood could be accurately substituted for infant blood, it would spare infants the discomfort of an invasive procedure and save both time and resources. While awaiting 48-hour blood culture results, we decide on clinical management based on whether the white blood cell (WBC) immature to total (I:T) granulocyte ratio is >or=0.2. Our goal was to assess the correlation of complete blood count (CBC), I:T ratio and blood culture results between umbilical cord and infant blood. We conducted a prospective cohort study comparing CBC/differential and blood culture results of paired samples of umbilical cord and infant blood from term newborns. We sent 113 paired samples of cord and infant venous blood for CBC/differential and blood culture. All 113 umbilical cord and infant blood cultures were negative, yielding a false-positive blood culture rate of zero. For 92% of babies, both the cord and infant blood I:T ratio were <0.2 or both were >or=0.2. Cord and infant WBC, hematocrit and platelet counts were moderately to highly correlated. We conclude that cord blood can be safely substituted for infant blood in routine sepsis evaluations of asymptomatic, term infants based on both the low false-positive cord blood culture rate and the significant association between high I:T ratios in cord and infant blood. Copyright (c) 2005 S. Karger AG, Basel.

  18. Low-dose aspirin for preventing recurrent venous thromboembolism.

    PubMed

    Brighton, Timothy A; Eikelboom, John W; Mann, Kristy; Mister, Rebecca; Gallus, Alexander; Ockelford, Paul; Gibbs, Harry; Hague, Wendy; Xavier, Denis; Diaz, Rafael; Kirby, Adrienne; Simes, John

    2012-11-22

    Patients who have had a first episode of unprovoked venous thromboembolism have a high risk of recurrence after anticoagulants are discontinued. Aspirin may be effective in preventing a recurrence of venous thromboembolism. We randomly assigned 822 patients who had completed initial anticoagulant therapy after a first episode of unprovoked venous thromboembolism to receive aspirin, at a dose of 100 mg daily, or placebo for up to 4 years. The primary outcome was a recurrence of venous thromboembolism. During a median follow-up period of 37.2 months, venous thromboembolism recurred in 73 of 411 patients assigned to placebo and in 57 of 411 assigned to aspirin (a rate of 6.5% per year vs. 4.8% per year; hazard ratio with aspirin, 0.74; 95% confidence interval [CI], 0.52 to 1.05; P=0.09). Aspirin reduced the rate of the two prespecified secondary composite outcomes: the rate of venous thromboembolism, myocardial infarction, stroke, or cardiovascular death was reduced by 34% (a rate of 8.0% per year with placebo vs. 5.2% per year with aspirin; hazard ratio with aspirin, 0.66; 95% CI, 0.48 to 0.92; P=0.01), and the rate of venous thromboembolism, myocardial infarction, stroke, major bleeding, or death from any cause was reduced by 33% (hazard ratio, 0.67; 95% CI, 0.49 to 0.91; P=0.01). There was no significant between-group difference in the rates of major or clinically relevant nonmajor bleeding episodes (rate of 0.6% per year with placebo vs. 1.1% per year with aspirin, P=0.22) or serious adverse events. In this study, aspirin, as compared with placebo, did not significantly reduce the rate of recurrence of venous thromboembolism but resulted in a significant reduction in the rate of major vascular events, with improved net clinical benefit. These results substantiate earlier evidence of a therapeutic benefit of aspirin when it is given to patients after initial anticoagulant therapy for a first episode of unprovoked venous thromboembolism. (Funded by National Health

  19. Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.

    PubMed

    Ozmen, Evrim; Algin, Oktay

    2016-07-12

    Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.

  20. [Emphysematous gastritis with concomitant portal venous air].

    PubMed

    Jeong, Min Yeong; Kim, Jin Il; Kim, Jae Young; Kim, Hyun Ho; Jo, Ik Hyun; Seo, Jae Hyun; Kim, Il Kyu; Cheung, Dae Young

    2015-02-01

    Emphysematous gastritis is a rare form of gastritis caused by infection of the stomach wall by gas forming bacteria. It is a very rare condition that carries a high mortality rate. Portal venous gas shadow represents elevation of intestinal luminal pressure which manifests as emphysematous gastritis or gastric emphysema. Literature reviews show that the mortality rate is especially high when portal venous gas shadow is present on CT scan. Until recently, the treatment of emphysematous gastritis has been immediate surgical intervention. However, there is a recent trend of avoiding surgery because of the frequent occurrence of post-operative complications such as anastomosis leakage. In addition, aggressive surgical treatment has failed to show significant improvement in prognosis. Recently, the authors experienced a case of emphysematous gastritis accompanied by portal venous gas which was treated successfully by conservative treatment without immediate surgical intervention. Herein, we present a case of emphysematous gastritis with concomitant portal venous air along with literature review.