Sample records for obviation retrofit kit

  1. Commercial vehicle (CV) retrofit safety device (RSD) kits project.

    DOT National Transportation Integrated Search

    2014-07-01

    Retrofit Safety Device (RSD) kits were developed and deployed on commercial vehicles as part of the U.S. DOT Connected Vehicle Safety Pilot to gain insight into the unique aspects of deploying connected vehicle technology in a commercial vehicle envi...

  2. Gravity flow operated small electricity generator retrofit kit to flour mill industry.

    PubMed

    Shekara, Prithivi; Kumar V, Pavan; Hosamane, Gangadharappa Gundabhakthara

    2013-10-01

    Flour milling is a grinding process to produce flour from wheat through comprehensive stages of grinding and separation. The primary energy is required to provide power used in grinding of wheat. In wheat milling, tempering is the process of adding water to wheat before milling to toughen the bran and mellow the endosperm. Gravity flow of the wheat is utilized to rotate the dampener wheel with cups to add water. Low cost gravity flow operated small electricity generator retrofit kit for dampener was designed and developed to justify low cost energy production without expensive solutions. Results of statistical analysis indicated that there was significant difference in mean values for voltage, rpm and flow rate at the 95% probability level. The resulted maximum mechanical power and measured electrical power were 5.1 W and 4.9 W respectively at wheat flow rate of 1.6 Kg/s and dampener wheel rotational velocity of 4.4 rad/s.

  3. RM12-2703 Advanced Rooftop Unit Control Retrofit Kit Field Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doebber, I.; Dean, J.; Dominick, J.

    2014-03-01

    As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft 2 exchangemore » store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).« less

  4. Cost effectiveness of a dealer's intervention in retrofitting rollover protective structures

    PubMed Central

    Myers, M; Cole, H; Westneat, S

    2005-01-01

    Objective: To evaluate the cost effectiveness of a 4.5 year education campaign that promoted farmers' adoption of rollover protective structures (ROPS) to prevent tractor overturn injuries. Design: Randomized controlled trial, decision analysis, and cost effectiveness analysis. Setting: One treatment county and one control county in the State of Kentucky. Intervention: A campaign by a local tractor and equipment dealership to encourage farmers to purchase and install ROPS and seatbelt retrofit kits for older tractors. Main outcome measures: Number of injuries averted and cost per injury averted. Results: The dealership's 4.5 year intervention was shown to potentially reduce both fatal (0.26) and non-fatal (1.50) injuries by 2.6% in its county over the intervention period using a 20 year analytic horizon. When extrapolated statewide, 6.7 lives would be saved and 39 non-fatal injuries would be averted over the combined 24.5 year combined intervention period and analytic horizon. The intervention for this period was cost effective with a "savings" of $35 713 per injury (fatal plus non-fatal) averted at a 4% discount rate. Conclusions: Tractor manufacturer promotions can influence their dealerships to promote ROPS retrofits by their customers. A manufacturer backed dealer ROPS retrofit campaign was cost effective in reducing overturn related injuries. PMID:15933410

  5. Phased Retrofits in Existing Homes in Florida Phase II. Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    K. Sutherland; Parker, D.; Martin, E.

    2016-02-01

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits duringmore » August 2013 - December 2013.« less

  6. Deep Residential Retrofits in East Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boudreaux, Philip R; Hendrick, Timothy P; Christian, Jeffrey E

    2012-04-01

    Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of homemore » energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal

  7. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, K.; Parker, D.; Martin, E.

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits duringmore » August 2013 - December 2013. A full account of Phase I of this project, including detailed home details and characterization, is found in Parker et al, 2015 (currently in draft). Phase II of this project, which is the focus of this report, applied the following additional retrofit measures to select homes that received a shallow retrofit in Phase I: a) Supplemental mini-split heat pump (MSHP) (6 homes); b) Ducted and space coupled Heat Pump Water Heater (8 homes); c) Exterior insulation finish system (EIFS) (1 homes); d) Window retrofit (3 homes); e) Smart thermostat (21 homes: 19 NESTs; 2 Lyrics); f) Heat pump clothes dryer (8 homes); g) Variable speed pool pump (5 homes).« less

  8. Guidelines for Retrofitting Bleachers.

    ERIC Educational Resources Information Center

    Consumer Product Safety Commission, Washington, DC.

    This brochure offers guidance on bleacher retrofitting to prevent falls, and suggests follow-up inspections and maintenance practices. Bleacher styles are described along with descriptions of bleacher-associated deaths, injuries, and hazards. Retrofitting recommendations are offered for guardrails and openings followed by retrofit strategies and…

  9. Evaluation of an LED Retrofit Project at Princeton University’s Carl Icahn Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Robert G.; Murphy, Arthur L.; Perrin, Tess E.

    The LED lighting retrofit at the Carl Icahn Laboratory of the Lewis-Sigler Institute for Integrative Genomics was the first building-wide interior LED project at Princeton University, following the University’s experiences from several years of exterior and small-scale interior LED implementation projects. The project addressed three luminaire types – recessed 2x2 troffers, cove and other luminaires using linear T8 fluorescent lamps, and CFL downlights - which combined accounted for over 564,000 kWh of annual energy, over 90% of the lighting energy used in the facility. The Princeton Facilities Engineering staff used a thorough process of evaluating product alternatives before selecting anmore » acceptable LED retrofit solution for each luminaire type. Overall, 815 2x2 luminaires, 550 linear fluorescent luminaires, and 240 downlights were converted to LED as part of this project. Based solely on the reductions in wattage in converting from the incumbent fluorescent lamps to LED retrofit kits, the annual energy savings from the project was over 190,000 kWh, a savings of 37%. An additional 125,000 kWh of energy savings is expected from the implementation of occupancy and task-tuning control solutions, which will bring the total savings for the project to 62%.« less

  10. Phased Retrofits in Existing Homes in Florida Phase I: Shallow and Deep Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Parker; Sutherland, K.; Chasar, D.

    2016-02-01

    The U.S. Department of Energy (DOE) Building America program, in collaboration with Florida Power and Light (FPL), conducted a phased residential energy-efficiency retrofit program. This research sought to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit - shallow and deep, with savings levels approaching the Building America program goals of reducing whole-house energy use by 40%. Under the Phased Deep Retrofit (PDR) project, we have installed phased, energy-efficiency retrofits in a sample of 56 existing, all-electric homes. End-use savings and economic evaluation results from the phased measure packages and singlemore » measures are summarized in this report.« less

  11. Building Energy Model Development for Retrofit Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chasar, David; McIlvaine, Janet; Blanchard, Jeremy

    2012-09-30

    Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 22 deep energy retrofits across the nation, 6 homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). However, assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research addresses a method to moremore » reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information in not available. A metered home, Riverdale, was selected as a test case for development of a modeling procedure to account occupancy and weather factors, potentially creating more accurate estimates of energy savings. This “true up” procedure was developed using Energy Gauge USA software and post-retrofit homeowner information and utility bills. The 12 step process adjusts the post-retrofit modeling results to correlate with post-retrofit utility bills and known occupancy information. The “trued” post retrofit model is then used to estimate pre-retrofit energy consumption by changing the building efficiency characteristics to reflect the pre-retrofit condition, but keeping all weather and occupancy-related factors the same. This creates a pre-retrofit model that is more comparable to the post-retrofit energy use profile and can improve energy savings estimates. For this test case, a home for which pre- and post- retrofit utility bills were available was selected for comparison and assessment of the accuracy of the “true up” procedure. Based on the current method, this procedure is quite time intensive. However, streamlined processing spreadsheets

  12. Steel bridge retrofit evaluation

    NASA Astrophysics Data System (ADS)

    Prine, David W.

    1998-03-01

    The development of a retrofit design aimed at retarding or eliminating fatigue crack growth in a large bridge can be a very difficult and expensive procedure. Analytical techniques frequently do not provide sufficient accuracy when applied to complex structural details. The Infrastructure Technology Institute (ITI) of Northwestern University, under contract to the California Department of Transportation (Caltrans), recently applied experimental state-of-the-art NDE technology to the Interstate 80 bridge over the Sacramento River near Sacramento, California (Bryte Bend). Acoustic emission monitoring was applied in conjunction with strain gage monitoring to aid in characterizing the retrofits' effect on existing active fatigue cracks. The combined test results clearly showed that one retrofit design was superior to the other.

  13. Techni-kits and Techni-kit Building Systems

    NASA Technical Reports Server (NTRS)

    Callender, E. D.; Hartsough, C.; Morris, R. V.; Yamamoto, Y.

    1985-01-01

    Techni-kits consists of theories, methods, standards and computer based tools that assist in design of information-intensive systems. Techni-kit "building system" is techni-kit that builds techni-kits.

  14. Engine Company Evaluation of Feasibility of Aircraft Retrofit Water-Injected Turbomachines

    NASA Technical Reports Server (NTRS)

    Becker, Arthur

    2006-01-01

    This study supports the NASA Glenn Research Center and the U.S. Air Force Research Laboratory in their efforts to evaluate the effect of water injection on aircraft engine performance and emissions. In this study, water is only injected during the takeoff and initial climb phase of a flight. There is no water injection during engine start or ground operations, nor during climb, cruise, descent, or landing. This study determined the maintenance benefit of water injection during takeoff and initial climb and evaluated the feasibility of retrofitting a current production engine, the PW4062 (Pratt & Whitney, East Hartford, CT), with a water injection system. Predicted NO(x) emissions based on a 1:1 water-tofuel ratio are likely to be reduced between 30 to 60 percent in Environmental Protection Agency parameter (EPAP). The maintenance cost benefit for an idealized combustor water injection system installed on a PW4062 engine in a Boeing 747-400ER aircraft (The Boeing Company, Chicago, IL) is computed to be $22 per engine flight hour (EFH). Adding water injection as a retrofit kit would cost up to $375,000 per engine because of the required modifications to the fuel system and addition of the water supply system. There would also be significant nonrecurring costs associated with the development and certification of the system that may drive the system price beyond affordability.

  15. Energy Retrofit for Aging K-12 Schools.

    ERIC Educational Resources Information Center

    3D/International, Houston, TX.

    Successfully retrofitting aging K-12 schools using energy conservation measures (ECM) that can improve the physical plant and reduce energy consumption are explored. Topics explore how certain ECM measures can benefit educational facilities, why retrofitting begun sooner rather than later is important, how to finance the retrofit program, and the…

  16. Effect of External Post-tensioning in Retrofitting of RC Beams

    NASA Astrophysics Data System (ADS)

    Manisekar, R.

    2018-05-01

    There are large number of existing concrete bridges in distressed condition in India and other countries, and they need retrofitting solutions. External post-tensioning is a prime technique for bridge retrofitting. It is being applied for retrofitting of bridges in India and other countries. Although the technique is becoming popular in retrofitting, various issues regarding performance of post-retrofitting behaviour need to be studied in detail. RC beam specimens of rectangular section were distressed by means of cracks to a certain limit, and were retrofitted by external post-tensioning. Retrofitted specimens were tested to fail to study the post-retrofitting behaviour. Retrofitting has increased the ultimate load carrying capacity by 81% with reference to the control beam, and recovered the deflection. This paper intends to report the results of the experimental investigations, and conclusions.

  17. Retrofitted supersymmetric models

    NASA Astrophysics Data System (ADS)

    Bose, Manatosh

    This thesis explores several models of metastable dynamic supersymmetry breaking (MDSB) and a supersymmetric model of hybrid inflation. All of these models possess discrete R-symmetries. We specially focus on the retrofitted models for supersymmetry breaking models. At first we construct retrofitted models of gravity mediation. In these models we explore the genericity of the so-called "split supersymmetry." We show that with the simplest models, where the goldstino multiplet is neutral under the discrete R-symmetry, a split spectrum is not generic. However if the goldstino superfield is charged under some symmetry other than the R-symmetry, then a split spectrum is achievable but not generic. We also present a gravity mediated model where the fine tuning of the Z-boson mass is dictated by a discrete choice rather than a continuous tuning. Then we construct retrofitted models of gauge mediated SUSY breaking. We show that, in these models, if the approximate R-symmetry of the theory is spontaneously broken, the messenger scale is fixed; if explicitly broken by retrofitted couplings, a very small dimensionless number is required; if supergravity corrections are responsible for the symmetry breaking, at least two moderately small couplings are required, and that there is a large range of possible messenger scales. Finally we switch our attention to small field hybrid inflation. We construct a model that yields a spectral index ns = 0.96. Here, we also briefly discuss the possibility of relating the scale of inflation with the dynamics responsible for supersymmetry breaking.

  18. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  19. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Applicability. Chemical kits and first aid kits... assigned to the chemical kit and first aid kit as a whole must be the most stringent packing group assigned...

  20. Proven Performance of Seven Cold Climate Deep Retrofit Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osser, R.; Neuhauser, K.; Ueno, K.

    2012-06-01

    Seven test homes located in Massachusetts are examined within this report. The retrofit strategies of each home are presented along with a comparison of the pre- and post-retrofit airtightness achieved by the group. Pre- and post-retrofit utility bills were collected; energy models were used to estimate pre-retrofit energy use when bills were unavailable.

  1. Infrastructure Retrofit Design via Composite Mechanics

    NASA Technical Reports Server (NTRS)

    Chamis, Christos, C.; Gotsis,Pascal K.

    1998-01-01

    Select applications are described to illustrate the concept for retrofitting reinforced concrete infrastructure with fiber reinforced plastic laminates. The concept is first illustrated by using an axially loaded reinforced concrete column. A reinforced concrete arch and a dome are then used to illustrate the versatility of the concept. Advanced methods such as finite element structural analysis and progressive structural fracture are then used to evaluate the retrofitting laminate adequacy. Results obtains show that retrofits can be designed to double and even triple the as-designed load of the select reinforced concrete infrastructures.

  2. Retrofitting a 1960s Split-Level, Cold-Climate Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puttagunta, Srikanth

    2015-07-13

    National programs such as Home Performance with ENERGY STAR® and numerous other utility air-sealing programs have made homeowners aware of the benefits of energy-efficiency retrofits. Yet these programs tend to focus only on the low-hanging fruit: they recommend air sealing the thermal envelope and ductwork where accessible, switching to efficient lighting and low-flow fixtures, and improving the efficiency of mechanical systems (though insufficient funds or lack of knowledge to implement these improvements commonly prevent the implementation of these higher cost upgrades). At the other end of the spectrum, various utilities across the country are encouraging deep energy retrofit programs. Althoughmore » deep energy retrofits typically seek 50% energy savings, they are often quite costly and are most applicable to gut-rehab projects. A significant potential for lowering energy use in existing homes lies between the lowhanging fruit and deep energy retrofit approaches—retrofits that save approximately 30% in energy compared to the pre-retrofit conditions. The energy-efficiency measures need to be nonintrusive so the retrofit projects can be accomplished in occupied homes.« less

  3. Building America Case Study: Pilot Demonstration of Phased Energy Efficiency Retrofits: Deep Retrofits, Central and South Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Parker, K. Sutherland, D. Chasar, J. Montemurno, B. Amos, J. Kono

    2017-02-01

    The Florida Solar Energy Center (FSEC), in collaboration with Florida Power & Light (FPL), is pursuing a phased residential energy-efficiency retrofit program in Florida. Researchers are looking to establish the impacts of technologies of two retrofit packages -- shallow and deep -- on annual energy and peak energy reductions.

  4. Building America Case Study: Pilot Demonstration of Phased Energy Efficiency Retrofits: Deep Retrofits, Central and South Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-02-22

    The Florida Solar Energy Center (FSEC), in collaboration with Florida Power & Light (FPL), is pursuing a phased residential energy-efficiency retrofit program in Florida. Researchers are looking to establish the impacts of technologies of two retrofit packages -- shallow and deep -- on annual energy and peak energy reductions.

  5. Evaluation of Eco-Efficiency and Performance of Retrofit Materials

    NASA Astrophysics Data System (ADS)

    Gopinath, Smitha; Rama Chandra Murthy, A.; Iyer, Nagesh R.; Kokila, S.

    2015-12-01

    In this work three materials namely Fiber Reinforced Polymer (FRP), ferrocement and Textile Reinforced Concrete (TRC) have been evaluated towards their performance efficiency and eco-effectiveness for sustainable retrofitting applications. Investigations have been carried out for flexural strengthening of RC beams with FRP, ferrocement and TRC. It is observed that in the case of FRP, it is not possible to tailor the material according to design requirements and most of the time strengthened structure becomes over stiff. Eco-effectiveness of these retrofitting materials has been evaluated by computing the embodied energy. It is observed that the amount of CO2 emitted by TRC is less compared to other retrofit materials. Further, the performance point of retrofitted RC frames has been evaluated and damage index has been calculated to find out the effective retrofit material. It is concluded that, if RC frame is retrofitted with FRP and TRC, it undergoes less damage compared to ferrocement.

  6. Seismic retrofit benefit considering statewide transportation assessment.

    DOT National Transportation Integrated Search

    2015-06-01

    The purpose of this study was to identify and demonstrate a methodology to prioritize bridges for : retrofit in the State of Oregon. Given the limited resources available, retrofitting all vulnerable bridges in the foreseeable : future would not be i...

  7. Fish passage through retrofitted culverts : final report.

    DOT National Transportation Integrated Search

    2004-11-01

    Long term and short term studies of fish movement were conducted at several retrofitted culverts within Oregon. This was done to assess the effectiveness of retrofitting culverts with baffles to improve fish passage. The long term results showed that...

  8. Innovative Retrofit Insulation Strategies for Concrete Masonry Foundations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huelman, P.; Goldberg, L.; Jacobson, R.

    This study was designed to test a new approach for foundation insulation retrofits, with the goal of demonstrating improved moisture control, improved occupant comfort, and reduced heat loss. Because conducting experimental research on existing below-grade assemblies is very difficult, most of the results are based on simulations. The retrofit approach consists of filling open concrete block cores with an insulating material and adding R-10 exterior insulation that extends 1 ft below grade. The core fill is designed to improve the R-value of the foundation wall and increase the interior wall surface temperature, but more importantly to block convection currents thatmore » could otherwise increase moisture loads on the foundation wall and interior space. The exterior insulation significantly reduces heat loss through the most exposed part of the foundation and further increases the interior wall surface temperature. This improves occupant comfort and decreases the risk of condensation. Such an insulation package avoids the full-depth excavation necessary for exterior insulation retrofits, reduces costs, and eliminates the moisture and indoor air quality risks associated with interior insulation retrofits. Retrofit costs for the proposed approach were estimated at roughly half those of a full-depth exterior insulation retrofit.« less

  9. Choosing the Right Fireplace or Fireplace Retrofit Device

    EPA Pesticide Factsheets

    This page is about choosing a fireplace or fireplace retrofit device, including information on hang tags and a list of fireplaces and retrofits that have qualified under the voluntary fireplace program

  10. Quantifying the Financial Benefits of Multifamily Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Philbrick, D.; Scheu, R.; Brand, L.

    Increasing the adoption of energy efficient building practices will require the energy sector to increase their understanding of the way that retrofits affect multifamily financial performance as well as how those indicators are interpreted by the lending and appraisal industries. This project analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy efficiency retrofits and financial performance on three levels: building, city, and community. The project goals were to increase the data and analysis in the growing body of multifamily financial benefits work as well provide a framework formore » other geographies to produce similar characterization. The goals are accomplished through three tasks. Task one: A pre- and post-retrofit analysis of thirteen Chicago multifamily buildings. Task two: A comparison of Chicago income and expenses to two national datasets. Task three: An in-depth look at multifamily market sales data and the subsequent impact of buildings that undergo retrofits.« less

  11. Quantifying the Financial Benefits of Multifamily Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Philbrick; Scheu, R.; Brand, L.

    The U.S. Department of Energy’s Building America research team Partnership for Advanced Residential Retrofit analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy-efficiency retrofits and financial performance on three levels: building, city, and community.

  12. Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farley, Jenne; Ruch, Russell

    This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depleting rental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

  13. Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farley, Jenne; Ruch, Russell

    This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depletingrental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

  14. Measure Guideline. Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musunuru, S.; Pettit, B.

    2015-04-30

    This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  15. Major Energy Conservation Retrofits: A Planning Guide for Northern Climates.

    ERIC Educational Resources Information Center

    Quivik, Fredric

    Energy-efficient retrofits are suggested as alternatives to conventional weatherization practices in this three-chapter report. Chapter 1 provides information necessary to help readers decide if a major energy retrofit is the right approach to a particular housing situation. Chapter 2 examines various aspects of retrofit designing, considering…

  16. Seismic retrofit workshop

    DOT National Transportation Integrated Search

    2006-11-01

    Metallic dampers were proposed for the seismic retrofit of deficient highway bridges by the University of Missouri-Rolla (UMR) under the sponsorship of Missouri Department of Transportation (MODOT). A research project (MODOT Study No. RI 01-028) on t...

  17. Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musunuru, S.; Pettit, B.

    2015-04-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits has the potential to adversely affect the durability of the wall; this document includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  18. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, K.; Parker, D.; Martin, E.

    Originally published in February 2016, this revision contains an added section called 'Evaluation of Complete Central System Replacement with Inverter-Driven Heat Pump,' which presents the designs and energy savings evaluations of two different schemes wherein inverter-driven systems replaced a home's existing central system. Analyses for three additional retrofit measures were bolstered by longer-term data; these are described in the sections on supplemental mini-split heat pumps (MSHPs), smart thermostats, and heat pump clothes dryers. The sections on supplemental MSHPs and smart thermostats were also enhanced with larger sample sizes and projections of weather-normalized annual energy savings. Finally, peak system hour energymore » demand-reduction predictions are provided for all retrofit measures where meaningful impacts could be drawn.« less

  19. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, K.; Parker, D.; Martin, E.

    Originally published in February 2016, this revision contains an added section called 'Evaluation of Complete Central System Replacement with Inverter-Driven Heat Pump,' which presents the designs and energy savings evaluations of two different schemes wherein inverter-driven systems replaced a home’s existing central system. Analyses for three additional retrofit measures were bolstered by longer-term data; these are described in the sections on supplemental mini-split heat pumps (MSHPs), smart thermostats, and heat pump clothes dryers. The sections on supplemental MSHPs and smart thermostats were also enhanced with larger sample sizes and projections of weather-normalized annual energy savings. Finally, peak system hour energymore » demand-reduction predictions are provided for all retrofit measures where meaningful impacts could be drawn.« less

  20. Minnesota retrofit insulation in situ test program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-06-01

    The use of cellulose, glass fiber, rock/slag fiber and urea formaldehyde installed as retrofit insulation materials in residential walls and ceilings was studied. Homes were selected for testing according to the type of retrofit insulation, age of retrofit insulation and whether the retrofit was in the wall or ceiling. The total project was comprised of 22 wall and 48 ceiling samples. Samples of retrofit insulation were taken from an area of three to four square feet in the ceiling or wall of the home. The sample volume was measured, the sample removed and double-sealed in polyethylene bags. The samples weremore » shipped to the laboratory for testing. Laboratory measurements were made of density, moisture content, thermal resistance, and relative flammability of each sample. Additionally, the friability and compressive strength of each urea-formaldehyde foam sample was measured. The following results were obtained. Cellulosic loose fill insulation tests indicated that settling and moisture build-up are not serious problems. Flammability is a concern. Age did not affect the properties of the cellulosic loose fill, but fungal growth was evident. Shrinkage, ranging from 2.5 to 9 percent, averaging 4.5 percent, was exhibited. Degradation of the foam samples with time did not occur. Density was the most critical property affecting the other properties. The higher the density, the higher the thermal resistence per inch, the lower the friability and the higher the compressive strength. The accurate prediction of the fiber diameter, amount of unfiberized mineral, and extent of modular clumping thermal resistance of loose fill mineral fiber insulations is related to and is not solely a factor of density. The materials in this sample did not noticeably affect the structure or wiring of the retrofitted homes. (LCL)« less

  1. Retrofitting Steam Turbines with Expired Service Life

    NASA Astrophysics Data System (ADS)

    Dubrovskii, V. G.; Zubov, A. P.; Koshelev, S. A.; Babiev, A. N.; Kremer, V. L.

    2018-06-01

    Many pieces of equipment installed at thermal power stations (TPS) have an expired service life or are close to expiry and are obsolete. In addition, the structure of heat consumption by end users has changed. Among the ways for solving the problem of aging equipment is the retrofitting of turbines that allows for service life recovery and improvement of their performance to the modern level. The service life is recovered through replacement of high-temperature assemblies and parts of a turbine, and the performance is improved by retrofitting and major overhaul of low-temperature assemblies. Implementation of modern engineering solutions and numerical methods in designing upgraded flow paths of steam turbines considerably improves the turbine effectiveness. New flow paths include sabre-like guide vanes, integrally-machined shrouds, and effective honeycomb or axial-radial seals. The flow paths are designed using optimization and hydraulic simulation methods as well as approaches for improving the performance on the turbine blading and internal steam flow paths. Retrofitting of turbines should be performed to meet the customers' needs. The feasibility of implementation of one or another alternative must be determined on a case-by-case basis depending on the turbine conditions, the availability of reserves for generating live steam and supplying circulation water, and the demands and capacities for generation and delivery of power and heat. The main principle of retrofitting is to retain the foundation and the auxiliary and heat-exchange equipment that is fit for further operation. With the example of PT-60-130 and T-100-130, the experience is presented of a comprehensive approach to retrofitting considering the customer's current needs and the actual equipment conditions. Due to the use of modern engineering solutions and procedures, retrofitting yields updating and upgrading of the turbine at a relatively low cost.

  2. Evaluation of NOx emissions of a retrofitted Euro 5 passenger car for the Horizon prize "Engine retrofit".

    PubMed

    Giechaskiel, Barouch; Suarez-Bertoa, Ricardo; Lähde, Tero; Clairotte, Michael; Carriero, Massimo; Bonnel, Pierre; Maggiore, Maurizio

    2018-06-13

    The Horizon 2020 prize for the "Engine Retrofit for Clean Air" aims at reducing the pollution in cities by spurring the development of retrofit technology for diesel engines. A Euro 5 passenger car was retrofitted with an under-floor SCR (Selective Catalytic Reduction) for NO x catalyst in combination with a solid ammonia based dosing system as the NO x reductant. The vehicle was tested both on the road and on the chassis dynamometer under various test cycles and ambient temperatures. The NO x emissions were reduced by 350-1100 mg/km (60-85%) in the laboratory depending on the test cycle and engine conditions (cold or hot start), except at type approval conditions. The reduction for cold start urban cycles was < 75 mg/km (< 15%). The on road and laboratory tests were inline. In some high speed conditions significant increase of ammonia (NH 3 ) and nitrous oxide (N 2 O) were measured. No effect was seen on other pollutants (hydrocarbons, carbon monoxide and particles). The results of the present study show that retrofitting high emitting vehicles can significantly reduce vehicle NO x emissions and ultimately pollution in cities. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Retrofit of a Multifamily Mass Masonry Building in New England

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goalsmore » but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.« less

  4. GridKit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peles, Slaven

    2016-11-06

    GridKit is a software development kit for interfacing power systems and power grid application software with high performance computing (HPC) libraries developed at National Labs and academia. It is also intended as interoperability layer between different numerical libraries. GridKit is not a standalone application, but comes with a suite of test examples illustrating possible usage.

  5. Attic Retrofits Using Nail-Base Insulated Panels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, David; Kochkin, Vladimir

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  6. Retrofit California Overview and Final Reports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choy, Howard; Rosales, Ana

    Energy efficiency retrofits (also called upgrades) are widely recognized as a critical component to achieving energy savings in the building sector to help lower greenhouse gas (GHG) emissions. To date, however, upgrades have accounted for only a small percentage of aggregate energy savings in building stock, both in California and nationally. Although the measures and technologies to retrofit a building to become energy efficient are readily deployed, establishing this model as a standard practice remains elusive. Retrofit California sought to develop and test new program models to increase participation in the energy upgrade market in California. The Program encompassed 24more » pilot projects, conducted between 2010 and mid-2013 and funded through a $30 million American Recovery and Reinvestment Act (ARRA) grant from the U.S. Department of Energy’s (DOE) Better Buildings Neighborhood Program (BBNP). The broad scope of the Program can be seen in the involvement of the following regionally based Grant Partners: Los Angeles County (as prime grantee); Association of Bay Area Governments (ABAG), consisting of: o StopWaste.org for Alameda County o Regional Climate Protection Authority (RCPA) for Sonoma County o SF Environment for the City and County of San Francisco o City of San Jose; California Center for Sustainable Energy (CCSE) for the San Diego region; Sacramento Municipal Utilities District (SMUD). Within these jurisdictions, nine different types of pilots were tested with the common goal of identifying, informing, and educating the people most likely to undertake energy upgrades (both homeowners and contractors), and to provide them with incentives and resources to facilitate the process. Despite its limited duration, Retrofit California undoubtedly succeeded in increasing awareness and education among home and property owners, as well as contractors, realtors, and community leaders. However, program results indicate that a longer timeframe will be needed

  7. Telescience Resource Kit

    NASA Technical Reports Server (NTRS)

    Schneider, Michelle

    2003-01-01

    This viewgraph representation provides an overview of the Telescience Resource Kit. The Telescience Resource Kit is a pc-based telemetry and command system that will be used by scientists and engineers to monitor and control experiments located on-board the International Space Station (ISS). Topics covered include: ISS Payload Telemetry and Command Flow, kit computer applications, kit telemetry capabilities, command capabilities, and training/testing capabilities.

  8. Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neuhauser, K.

    2015-01-01

    This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board, and is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit processes. The guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations.

  9. Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puttagunta, S.

    2013-04-01

    In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit testmore » homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.« less

  10. The Retrofit Puzzle Extended: Optimal Fleet Owner Behavior over Multiple Time Periods

    DOT National Transportation Integrated Search

    2009-08-04

    In "The Retrofit Puzzle: Optimal Fleet Owner Behavior in the Context of Diesel Retrofit Incentive Programs" (1) an integer program was developed to model profit-maximizing diesel fleet owner behavior when selecting pollution reduction retrofits. Flee...

  11. Seismic retrofitting manual for highway structures. Part 1, Bridges

    DOT National Transportation Integrated Search

    2006-01-01

    This report is the first of a two-part publication entitled "Seismic retrofitting manual for highway structures". Part 1 of this manual is based on previous Federal Highway Administration (FHWA) publications on this subject including Seismic Retrofit...

  12. Diesel retrofit assessment for NYS DOT to retrofit its existing engine fleet.

    DOT National Transportation Integrated Search

    2010-08-01

    The NYS DEC has required the use of retrofit technologies for various state agency, state public authority, and regional public authority heavy duty vehicles, as well as heavy duty vehicles used on behalf of such agencies and authorities. This report...

  13. Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neuhauser, Ken

    2015-01-01

    This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

  14. Retrofit of a MultiFamily Mass Masonry Building in New England

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Kerrigan, P.; Wytrykowska, H.

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goalsmore » but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.« less

  15. Building America Case Study: Pilot Demonstration of Phased Energy Efficiency Retrofits: Shallow Retrofit Results, Central and South Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-02-22

    The Florida Solar Energy Center (FSEC), in collaboration with Florida Power & Light (FPL), is pursuing a phased residential energy-efficiency retrofit program in Florida. Researchers are looking to establish the impacts of technologies of two retrofit packages -- shallow and deep -- on annual energy and peak energy reductions. Sixty homes have been instrumented to record total house power and detailed energy end-use data on all appliances as well as household interior temperature and relative humidity conditions.

  16. Building America Case Study: Pilot Demonstration of Phased Energy Efficiency Retrofits: Shallow Retrofit Results, Central and South Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Parker, K. Sutherland, D. Chasar, J. Montemurno, B. Amos, J. Kono

    2017-02-01

    The Florida Solar Energy Center (FSEC), in collaboration with Florida Power & Light (FPL), is pursuing a phased residential energy-efficiency retrofit program in Florida. Researchers are looking to establish the impacts of technologies of two retrofit packages -- shallow and deep -- on annual energy and peak energy reductions. Sixty homes have been instrumented to record total house power and detailed energy end-use data on all appliances as well as household interior temperature and relative humidity conditions.

  17. Retrofit Gloveport Cover and Security Device

    DOE PAGES

    Hinckley, Jon E.

    2015-01-01

    The world of glovebox work in the areas of science and manufacturing is in a consistent state of flux due to the inherent nature of changing missions. These rapidly changing work environments result in almost continuous regulatory changes within the codes and standards in order to maintain worker and environmental safety. Gloveboxes designed and manufactured prior to these regulations are not easy to update or retrofit to accommodate new requirements. In order to meet the challenge of retrofitting gloveboxes to the meet the requirements, the following solutions have been developed.

  18. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Podorson, David; Varshney, Kapil

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programsmore » are discussed in detail.« less

  19. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Podorson, D.; Varshney, K.

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programsmore » are discussed in detail.« less

  20. Whole-Building Retrofits | Climate Neutral Research Campuses | NREL

    Science.gov Websites

    Whole-Building Retrofits Whole-Building Retrofits Buildings are the greatest energy consumers on check. As buildings age, O&M costs reach the point where they are best addressed through a top-to wall insulation. Renovations are costly and disruptive, but they are the best way to adapt an aging

  1. Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gates, C.; Neuhauser, K.

    2014-03-01

    Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach tomore » implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.« less

  2. Blast Design of Reinforced Concrete and Masonry Components Retrofitted with FRP

    DTIC Science & Technology

    2010-07-01

    1 BLAST DESIGN OF REINFORCED CONCRETE AND MASONRY COMPONENTS RETROFITTED WITH FRP Marlon L. Bazan, Ph.D. and Charles J. Oswald, P.E., Ph.D...as an alternative to traditional methods for strengthening and retrofitting concrete and masonry structures to resist blast loads. The development...and experimental validation of a methodology for modeling the response of blast loaded concrete and masonry structural components retrofitted with FRP

  3. Infrastructure optimisation via MBR retrofit: a design guide.

    PubMed

    Bagg, W K

    2009-01-01

    Wastewater management is continually evolving with the development and implementation of new, more efficient technologies. One of these is the Membrane Bioreactor (MBR). Although a relatively new technology in Australia, MBR wastewater treatment has been widely used elsewhere for over 20 years, with thousands of MBRs now in operation worldwide. Over the past 5 years, MBR technology has been enthusiastically embraced in Australia as a potential treatment upgrade option, and via retrofit typically offers two major benefits: (1) more capacity using mostly existing facilities, and (2) very high quality treated effluent. However, infrastructure optimisation via MBR retrofit is not a simple or low-cost solution and there are many factors which should be carefully evaluated before deciding on this method of plant upgrade. The paper reviews a range of design parameters which should be carefully evaluated when considering an MBR retrofit solution. Several actual and conceptual case studies are considered to demonstrate both advantages and disadvantages. Whilst optimising existing facilities and production of high quality water for reuse are powerful drivers, it is suggested that MBRs are perhaps not always the most sustainable Whole-of-Life solution for a wastewater treatment plant upgrade, especially by way of a retrofit.

  4. Retrofitting Las Vegas. Implementing Energy Efficiency in Two Las Vegas Test Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puttagunta, S.

    2013-04-01

    In 2009, the state of Nevada received nearly $40 million in Neighborhood Stabilization Funds from the Department of Housing and Urban Development to use to stabilize communities that have suffered from foreclosures and abandonment. In order to provide guidance to local officials and maximize how effectively this NSP funding is used in retrofitting homes, the CARB team provided design specifications, energy modeling, and technical support for the BARA team and its local partners—Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada—for two retrofit test homes. One home demonstrated a modest retrofit and the other a deepmore » energy retrofit. This report describes the retrofit packages, which were used as an educational experience for home performance professionals, building trades, remodelers, and the general public.« less

  5. Considerations for the retrofit of data link

    NASA Technical Reports Server (NTRS)

    Corwin, William H.; Mccauley, Hugo W.

    1990-01-01

    Human factors issues related to the retrofit of data link in commercial transport aircraft are discussed. Topics that must be considered for data link implementation include, the loss of the party line, (i.e., the availability to all aircraft of information transmitted on a common voice frequency), and the scheduling of information to the flight crew. This paper focuses primarily on the human factors issues related to retrofit of Mode S. Retrofits is a difficult task because panel space accessible to flight crew members is limited. As with all cockpit equipment, data link implementation will have to comply with Federal Aviation Regulation 25.1523, which requires the manufacturer to address the conspicuity and ease of use of the data link device, and to assess the impact on crew workload. Operational sequence diagrams are provided to illustrate a methodology that can be used to decompose the flight crew body channel utilization of candidate avionics configurations in order to optimize the pilot-vehicle interface.

  6. The social marketing of safety behaviors: a quasi-randomized controlled trial of tractor retrofitting incentives.

    PubMed

    Sorensen, Julie A; Jenkins, Paul L; Emmelin, Maria; Stenlund, Hans; Weinehall, Lars; Earle-Richardson, Giulia B; May, John J

    2011-04-01

    We assessed the effect of social marketing incentives on dispositions toward retrofitting and retrofitting behavior among farmers whose tractors lacked rollover protective structures. From 2006 to 2007, we conducted a quasi-randomized controlled trial with 391 farm owners in New York and Pennsylvania surveyed before and after exposure to 1 of 3 tractor retrofitting incentive combinations. These combinations were offered in 3 trial regions; region 1 received rebates; region 2 received rebates, messages, and promotion and was considered the social marketing region; and region 3 received messages and promotion. A fourth region served as a control. The social marketing region generated the greatest increases in readiness to retrofit, intentions to retrofit, and message recall. In addition, postintervention stage of change, intentions, attitudes, subjective norms, and perceived behavioral control levels were higher among farmers who had retrofitted tractors. Our results showed that a social marketing approach (financial incentives, tailored messages, and promotion) had the greatest influence on message recall, readiness to retrofit tractors, and intentions to retrofit tractors and that behavioral measures were fairly good predictors of tractor retrofitting behaviors.

  7. Retrofitting of Reinforced Concrete Beams using Reactive Powder Concrete (RPC)

    NASA Astrophysics Data System (ADS)

    Karthik, S.; Sundaravadivelu, Karthik

    2017-07-01

    Strengthening of existing damaged structures is one of the leading studies in civil engineering. The purpose of retrofitting is to structurally treat the member with an aim to restore the structure to its original strength. The focus of this project is to study the behaviour of damaged Reinforced Concrete beam retrofitted with Reactive Powder Concrete (RPC) Overlay. Reinforced concrete beams of length 1200 mm, width 100 mm and depth 200 mm were casted with M30 grade of concrete in the laboratory and cured for 28 days. One beam is taken as control and are tested under two point loading to find out ultimate load. Remaining beams are subjected to 90 % ultimate load of control beams. The partially damaged beams are retrofitted with Reactive Powder Concrete Overlay at the full tension face of the beam and side overlay depends upon the respectable retrofitting techniques with 10 mm and 20 mm thick layer to find optimum. Materials like steel fibres are added to enhance the ductility by eliminating coarse particle for homogeneity of the structure. Finally, the modes of failure for retrofitted beams are analysed experimentally under two point loading & compared the results with Control beam.

  8. Energy Retrofit--Step One.

    ERIC Educational Resources Information Center

    Canipe, Stephen L.; And Others

    1983-01-01

    A School Retrofit Design Analysis System (SRDAS) provides energy modeling analyses of school buildings. SRDAS has three subprograms that consider first, roof, windows, walls, floors, and infiltration sites; second, costs per student, compliance with national energy consumption norms, and electricity costs projections; and third, financial savings…

  9. The Social Marketing of Safety Behaviors: A Quasi–Randomized Controlled Trial of Tractor Retrofitting Incentives

    PubMed Central

    Jenkins, Paul L.; Emmelin, Maria; Stenlund, Hans; Weinehall, Lars; Earle-Richardson, Giulia B.; May, John J.

    2011-01-01

    Objectives. We assessed the effect of social marketing incentives on dispositions toward retrofitting and retrofitting behavior among farmers whose tractors lacked rollover protective structures. Methods. From 2006 to 2007, we conducted a quasi–randomized controlled trial with 391 farm owners in New York and Pennsylvania surveyed before and after exposure to 1 of 3 tractor retrofitting incentive combinations. These combinations were offered in 3 trial regions; region 1 received rebates; region 2 received rebates, messages, and promotion and was considered the social marketing region; and region 3 received messages and promotion. A fourth region served as a control. Results. The social marketing region generated the greatest increases in readiness to retrofit, intentions to retrofit, and message recall. In addition, postintervention stage of change, intentions, attitudes, subjective norms, and perceived behavioral control levels were higher among farmers who had retrofitted tractors. Conclusions. Our results showed that a social marketing approach (financial incentives, tailored messages, and promotion) had the greatest influence on message recall, readiness to retrofit tractors, and intentions to retrofit tractors and that behavioral measures were fairly good predictors of tractor retrofitting behaviors. PMID:21330581

  10. An actuarial approach to retrofit savings in buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.

    An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution ofmore » the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.« less

  11. Levitation Kits Demonstrate Superconductivity.

    ERIC Educational Resources Information Center

    Worthy, Ward

    1987-01-01

    Describes the "Project 1-2-3" levitation kit used to demonstrate superconductivity. Summarizes the materials included in the kit. Discusses the effect demonstrated and gives details on how to obtain kits. Gives an overview of the documentation that is included. (CW)

  12. Performance of school bus retrofit systems: ultrafine particles and other vehicular pollutants.

    PubMed

    Zhang, Qunfang; Zhu, Yifang

    2011-08-01

    This study evaluated the performance of retrofit systems for diesel-powered school buses, a diesel oxidation catalyst (DOC) muffler and a spiracle crankcase filtration system (CFS), regarding ultrafine particles (UFPs) and other air pollutants from tailpipe emissions and inside bus cabins. Tailpipe emissions and in-cabin air pollutant levels were measured before and after retrofitting when the buses were idling and during actual pick-up/drop off routes. Retrofit systems significantly reduced tailpipe emissions with a reduction of 20-94% of total particles with both DOC and CFS installed. However, no unequivocal decrease was observed for in-cabin air pollutants after retrofitting. The AC/fan unit and the surrounding air pollutant concentrations played more important roles for determining the in-cabin air quality of school buses than did retrofit technologies. Although current retrofit systems reduce children's exposure while waiting to board at a bus station, retrofitting by itself does not protect children satisfactorily from in-cabin particle exposures. Turning on the bus engine increased in-cabin UFP levels significantly only when the wind blew from the bus' tailpipe toward its hood with its windows open. This indicated that wind direction and window position are significant factors determining how much self-released tailpipe emissions may penetrate into the bus cabin. The use of an air purifier was found to remove in-cabin particles by up to 50% which might be an alternative short-to-medium term strategy to protect children's health.

  13. Cascade Apartments: Deep Energy Multifamily Retrofit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, A.; Mattheis, L.; Kunkle, R.

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit packagemore » after considering utility window incentives and KCHA capitol improvement funding.« less

  14. A decrease in ubiquitination and resulting prolonged life-span of KIT underlies the KIT overexpression-mediated imatinib resistance of KIT mutation-driven canine mast cell tumor cells.

    PubMed

    Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto

    2017-10-01

    Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.

  15. Retrofit raises efficiency, UPS production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-02-03

    When a 10-year-old turboexpander was retrofitted rather than replaced, the results were: an increase in turboexpander efficiency of seven percentage points. A plant output increase of 10%. A retrofit cost that was less than half that of a new machine. The turboexpander is located in the Burlington, N.J., Plant of Liquid Carbonic Industrial/Medical Corp. The company is the world's largest supplier of CO/sub 2/ and a major supplier of oxygen, nitrogen, and argon in liquid form. The heaviest use of energy is in the heat reduction processes involved in producing 300 tons of liquid product/day. In the 1960s, electricity inmore » the Burlington, N.J., area cost as little as 5 mils/kwh. Today the cost averages 56 mils. The turboexpander is the heart of this refrigeration system.« less

  16. EnergySmart Schools Tips: Retrofitting, Operating, and Maintaining Existing Buildings

    ERIC Educational Resources Information Center

    US Department of Energy, 2010

    2010-01-01

    Combining preventative operations and maintenance (O&M) with strategic retrofitting of building systems improves a school's energy performance. For schools with limited resources and experience, "quick wins" in O&M and retrofitting provide a valuable starting point to energy management. As a next step, strategically prioritizing long- and…

  17. Multi-criteria decision model for retrofitting existing buildings

    NASA Astrophysics Data System (ADS)

    Bostenaru Dan, M. D.

    2004-08-01

    Decision is an element in the risk management process. In this paper the way how science can help in decision making and implementation for retrofitting buildings in earthquake prone urban areas is investigated. In such interventions actors from various spheres are involved. Their interests range among minimising the intervention for maximal preservation or increasing it for seismic safety. Research was conducted to see how to facilitate collaboration between these actors. A particular attention was given to the role of time in actors' preferences. For this reason, on decision level, both the processural and the personal dimension of risk management, the later seen as a task, were considered. A systematic approach was employed to determine the functional structure of a participative decision model. Three layers on which actors implied in this multi-criteria decision problem interact were identified: town, building and element. So-called 'retrofit elements' are characteristic bearers in the architectural survey, engineering simulations, costs estimation and define the realms perceived by the inhabitants. This way they represent an interaction basis for the interest groups considered in a deeper study. Such orientation means for actors' interaction were designed on other levels of intervention as well. Finally, an 'experiment' for the implementation of the decision model is presented: a strategic plan for an urban intervention towards reduction of earthquake hazard impact through retrofitting. A systematic approach proves thus to be a very good communication basis among the participants in the seismic risk management process. Nevertheless, it can only be applied in later phases (decision, implementation, control) only, since it serves verifying and improving solution and not developing the concept. The 'retrofit elements' are a typical example of the detailing degree reached in the retrofit design plans in these phases.

  18. 77 FR 24505 - Hazard Mitigation Assistance for Wind Retrofit Projects for Existing Residential Buildings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ...] Hazard Mitigation Assistance for Wind Retrofit Projects for Existing Residential Buildings AGENCY... for Wind Retrofit Projects for Existing Residential Buildings. DATES: Comments must be received by... property from hazards and their effects. One such activity is the implementation of wind retrofit projects...

  19. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loomis, H.; Pettit, B.

    2015-06-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution that provides insulation to the interior of the wall assembly with the use of a double stud wall. The guide describes two approaches to retrofitting the existing the walls: one involving replacement of the existing cladding, and the other that leaves the existing cladding in place. It discusses the design principles related to the use of various insulation types, and provides strategies and procedures for implementing the double stud wall retrofit. It also evaluates important moisture-related and indoor air quality measures that need to be implemented to achieve amore » durable, high performance wall.« less

  20. Promoting seismic retrofit implementation through "nudge": using warranty as a driver.

    PubMed

    Fujimi, Toshio; Tatano, Hirokazu

    2013-10-01

    This article proposes a new type of warranty policy that applies the "nudge" concept developed by Thaler and Sunstein to encourage homeowners in Japan to implement seismic retrofitting. Homeowner adaptation to natural disasters through loss reduction measures is known to be inadequate. To encourage proactive risk management, the "nudge" approach capitalizes on how choice architecture can influence human decision-making tendencies. For example, people tend to place more value on a warranty for consumer goods than on actuarial value. This article proposes a "warranty for seismic retrofitting" as a "nudge" policy that gives homeowners the incentive to adopt loss reduction measures. Under such a contract, the government guarantees all repair costs in the event of earthquake damage to the house if the homeowner implements seismic retrofitting. To estimate the degree to which a warranty will increase the perceived value of seismic retrofitting, we use field survey data from 1,200 homeowners. Our results show that a warranty increases the perceived value of seismic retrofitting by an average of 33%, and an approximate cost-benefit analysis indicates that such a warranty can be more economically efficient than an ex ante subsidy. Furthermore, we address the failure of the standard expected utility model to explain homeowners' decisions based on warranty evaluation, and explore the significant influence of ambiguity aversion on the efficacy of seismic retrofitting and nonanalytical factors such as feelings or trust. © 2013 Society for Risk Analysis.

  1. Measuring energy-saving retrofits: Experiences from the Texas LoanSTAR program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haberl, J.S.; Reddy, T.A.; Claridge, D.E.

    1996-02-01

    In 1988 the Governor`s Energy Management Center of Texas received approval from the US Department of Energy to establish a $98.6 million state-wide retrofit demonstration revolving loan program to fund energy-conserving retrofits in state, public school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational and maintenance improvements, improve retrofit selection in future rounds of the LoanSTAR program, and initiate a data base of energy use in institutional and commercial buildings located in Texas. Thismore » report discusses the LoanSTAR MAP with an emphasis on the process of acquiring and analyzing data to measure savings from energy conservation retrofits when budgets are a constraint. This report includes a discussion of the program structure, basic measurement techniques, data archiving and handling, data reporting and analysis, and includes selected examples from LoanSTAR agencies. A summary of the program results for the first two years of monitoring is also included.« less

  2. Kits in Motion

    ERIC Educational Resources Information Center

    Gee, Maureen

    1975-01-01

    Discusses three kits developed by museums in British Columbia for use in rural classrooms. The science kit on marine biology consists of modules which included specimens, books, audiovisual materials and student activities. (BR)

  3. Numerical and Experimental Evaluation of Blast Retrofit of Windows

    DTIC Science & Technology

    2013-07-18

    Retrofitting windows against blast load environments is a topic under considerable investigation. The retrofits added to existing buildings need the strength...experimentally survived the desired loading environment. Two views of the posttest vertical blind system can be seen in Figure 8. Although the vertical...vertica Figure 8: Posttest views l blind system and the connections Both the numerical and experimental systems deformed in a similar

  4. Strengthening Building Retrofit Markets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Templeton, Mary; Jackson, Robert

    2014-04-15

    The Business Energy Financing (BEF) program offered commercial businesses in Michigan affordable financing options and other incentives designed to support energy efficiency improvements. We worked through partnerships with Michigan utilities, lenders, building contractors, trade associations, and other community organizations to offer competitive interest rates and flexible financing terms to support energy efficiency projects that otherwise would not have happened. The BEF program targeted the retail food market, including restaurants, grocery stores, convenience stores, and wholesale food vendors, with the goal of achieving energy efficiency retrofits for 2 percent of the target market. We offered low interest rates, flexible payments, easymore » applications and approval processes, and access to other incentives and rebates. Through these efforts, we sought to help customers strive for energy savings retrofits that would save 20 percent or more on their energy use. This program helped Michigan businesses reduce costs by financing energy efficient lighting, heating and cooling systems, insulation, refrigeration, equipment upgrades, and more. Businesses completed the upgrades with the help of our authorized contractors, and, through our lending partners, we provided affordable financing options.« less

  5. An experimental study on compressive behavior of rubble stone walls retrofitted with BFRP grids

    NASA Astrophysics Data System (ADS)

    Huang, Hui; Jia, Bin; Li, Wenjing; Liu, Xiao; Yang, Dan; Deng, Chuanli

    2018-03-01

    An experimental study was conducted to investigate the compressive behavior of rubble stone walls retrofitted with BFRP grids. The experimental program consisted of four rubble stone walls: one unretrofitted rubble stone wall (reference wall) and three BFRP grids retrofitted rubble stone walls. The main purpose of the tests was to gain a better understanding of the compressive behavior of rubble stone walls retrofitted with different amount of BFRP grids. The experimental results showed that the reference wall failed with out-of-plane collapse due to poor connection between rubble stone blocks and the three BFRP grids retrofitted walls failed with BFRP grids rupture followed by out-of-plane collapse. The measured compressive strength of the BFRP grids retrofitted walls is about 1.4 to 2.5 times of that of the reference wall. Besides, the rubble stone wall retrofitted with the maximum amount of BFRP grids showed the minimum vertical and out-of-plane displacements under the same load.

  6. First aid kit

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/001958.htm First aid kit To use the sharing features on this ... ahead, you can create a well-stocked home first aid kit. Keep all of your supplies in one ...

  7. Arkansas Solar Retrofit Guide. Greenhouses, Air Heaters and Water Heaters.

    ERIC Educational Resources Information Center

    Skiles, Albert; Rose, Mary Jo

    Solar retrofits are devices of structures designed to be attached to existing buildings to augment their existing heating sources with solar energy. An investigation of how solar retrofits should be designed to suit the climate and resources of Arkansas is the subject of this report. Following an introduction (section 1), section 2 focuses on…

  8. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loomis, H.; Pettit, B.

    2015-06-22

    This Measure Guideline describes a deep energy enclosure retrofit solution that provides insulation to the interior of the wall assembly with the use of a double-stud wall. The guide describes two approaches to retrofitting the existing walls—one that involves replacing the existing cladding and the other that leaves the cladding in place. This guideline also covers the design principles related to the use of various insulation types and provides strategies and procedures for implementing the double-stud wall retrofit. It also includes an evaluation of important moisture-related and indoor air quality measures that need to be implemented to achieve a durablemore » high-performance wall.« less

  9. Comparison of Home Retrofit Programs in Wisconsin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunningham, Kerrie; Hannigan, Eileen

    2013-03-01

    To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patternsmore » of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results-program cost and energy savings-to help understand the overall strengths and weaknesses or challenges of each model.« less

  10. Comparison of Home Retrofit Programs in Wisconsin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunningham, K.; Hannigan, E.

    2013-03-01

    To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patternsmore » of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results -- program cost and energy savings -- to help understand the overall strengths and weaknesses or challenges of each model.« less

  11. Creation of learning kits

    NASA Technical Reports Server (NTRS)

    Stow, D. A.; Estes, J. E.; Mertz, F. C.

    1981-01-01

    A learning kit is an essential part of any remote sensing workshop, course, or in-house training program to provide the "hands-on" experience of working with remotely sensed imagery. This is the objective of laboratory and field exercises as well as the reason behind the production of imagery/map kits. The way in which these learning kits (containing conventional remotely sensed and collateral data products) are put together is described and some concerns that influence the creation of learning kits are discussed. These include budgetary constraints, number of imagery types, and number of collateral data types.

  12. Aging obviates sex-specific physiological responses to exercise.

    PubMed

    Deschenes, Michael R; Taylor, Jessica L; Mangis, Katherine A

    2013-01-01

    Both sex and aging have been shown to affect physiological responses to exercise. The aim of the present investigation was to determine whether aging impacted the sex-specific nature of physiological responses to exercise commonly noted among young adults. Ten aged men (69.0 ± 1.7 years; mean ± SE) and 10 aged women (71.6 ± 1.3 years) reporting similar levels of habitual physical activity performed a 30-min exercise session at 60-65% of their predetermined peak oxygen uptake. Cardiovascular, thermoregulatory, and metabolic variables were assessed before exercise, at the 15th and 30th min of exercise, and at 5 and 15 min into a passive postexercise recovery period. Variables of interest were statistically analyzed via two-way analysis of variance with repeated measures; significance was set at P < 0.05. Significant effects of time (i.e., exercise) for each physiological variable of interest were identified, but not once was a significant effect of group (i.e., sex) detected. Exercise-induced physiological responses to prolonged, moderate intensity exercise were similar among aged men and aged women. This evidence that the sexually dimorphic nature of physiological responses to exercise is obviated with age should be taken into account when prescribing health-related exercise training programs for older individuals. Copyright © 2013 Wiley Periodicals, Inc.

  13. Strategies and Challenges for Energy Efficient Retrofitting: Study of the Empire State Building

    NASA Astrophysics Data System (ADS)

    De, B.; Mukherjee, M.

    2013-11-01

    Operational and maintenance cost of existing buildings is escalating making it tough for both the owner and the tenants. Retrofitting them with state of the art technologies help them to keep pace with amended recent code provisions and thus extending the older building stocks one more chance to live responsively. Retrofitted iconic buildings can thus retain their status in commerce driven real estate sector. It helps in reducing green house gas emission as well. World's iconic skyscraper, the Empire State Building (ESB), has undergone an exemplary retrofit process since 2008 to reduce its energy demands. To achieve the goal of operational cost and energy consumption reduction, stiff challenges had taken care in a systematic manner to realize benefit throughout the entire lifespan of the ESB. Least disturbances to the tenant and on-site component handling strategies required precise planning. The present paper explores strategies and process adopted for retrofitting the ESB, and derived insightful guidelines towards operational cost savings and energy efficiency of existing buildings through retrofitting.

  14. Retrofitting the Streetlights in Boise, Idaho

    ScienceCinema

    Young, Clay; Oliver, LeAnn; Bieter, David; Johnson, Michael; Oldemeyer, Neal

    2018-05-11

    Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and local quality of life.

  15. A regression-based approach to estimating retrofit savings using the Building Performance Database

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walter, Travis; Sohn, Michael D.

    Retrofitting building systems is known to provide cost-effective energy savings. This article addresses how the Building Performance Database is used to help identify potential savings. Currently, prioritizing retrofits and computing their expected energy savings and cost/benefits can be a complicated, costly, and an uncertain effort. Prioritizing retrofits for a portfolio of buildings can be even more difficult if the owner must determine different investment strategies for each of the buildings. Meanwhile, we are seeing greater availability of data on building energy use, characteristics, and equipment. These data provide opportunities for the development of algorithms that link building characteristics and retrofitsmore » empirically. In this paper we explore the potential of using such data for predicting the expected energy savings from equipment retrofits for a large number of buildings. We show that building data with statistical algorithms can provide savings estimates when detailed energy audits and physics-based simulations are not cost- or time-feasible. We develop a multivariate linear regression model with numerical predictors (e.g., operating hours, occupant density) and categorical indicator variables (e.g., climate zone, heating system type) to predict energy use intensity. The model quantifies the contribution of building characteristics and systems to energy use, and we use it to infer the expected savings when modifying particular equipment. We verify the model using residual analysis and cross-validation. We demonstrate the retrofit analysis by providing a probabilistic estimate of energy savings for several hypothetical building retrofits. We discuss the ways understanding the risk associated with retrofit investments can inform decision making. The contributions of this work are the development of a statistical model for estimating energy savings, its application to a large empirical building dataset, and a discussion of its use in informing

  16. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    PubMed

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  17. Design procedures of retrofitted bridge rail.

    DOT National Transportation Integrated Search

    2016-08-01

    The use of shallow embedment anchors in concrete is essential for retrofit applications; however, the combination of steel anchors, chemical adhesive, and concrete acting as a single tensile mechanism creates uncertainties in anchor strength and fail...

  18. Geothermal Energy Retrofit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bachman, Gary

    The Cleary University Geothermal Energy Retrofit project involved: 1. A thermal conductivity test; 2. Assessment of alternative horizontal and vertical ground heat exchanger options; 3. System design; 4. Asphalt was stripped from adjacent parking areas and a vertical geothermal ground heat exchanger system installed; 5. the ground heat exchanger was connected to building; 6. a system including 18 heat pumps, control systems, a manifold and pumps, piping for fluid transfer and ductwork for conditioned air were installed throughout the building.

  19. Disruption of c-Kit Signaling in Kit(W-sh/W-sh) Growing Mice Increases Bone Turnover.

    PubMed

    Lotinun, Sutada; Krishnamra, Nateetip

    2016-08-16

    c-Kit tyrosine kinase receptor has been identified as a regulator of bone homeostasis. The c-Kit loss-of-function mutations in WBB6F1/J-Kit(W/W-v) mice result in low bone mass. However, these mice are sterile and it is unclear whether the observed skeletal phenotype is secondary to a sex hormone deficiency. In contrast, C57BL/6J-Kit(W-sh)/(W-sh) (W(sh)/W(sh)) mice, which carry an inversion mutation affecting the transcriptional regulatory elements of the c-Kit gene, are fertile. Here, we showed that W(sh)/W(sh) mice exhibited osteopenia with elevated bone resorption and bone formation at 6- and 9-week-old. The c-Kit W(sh) mutation increased osteoclast differentiation, the number of committed osteoprogenitors, alkaline phosphatase activity and mineralization. c-Kit was expressed in both osteoclasts and osteoblasts, and c-Kit expression was decreased in W(sh)/W(sh)osteoclasts, but not osteoblasts, suggesting an indirect effect of c-Kit on bone formation. Furthermore, the osteoclast-derived coupling factor Wnt10b mRNA was increased in W(sh)/W(sh) osteoclasts. Conditioned medium from W(sh)/W(sh) osteoclasts had elevated Wnt10b protein levels and induced increased alkaline phosphatase activity and mineralization in osteoblast cultures. Antagonizing Wnt10b signaling with DKK1 or Wnt10b antibody inhibited these effects. Our data suggest that c-Kit negatively regulates bone turnover, and disrupted c-Kit signaling couples increased bone resorption with bone formation through osteoclast-derived Wnt 10 b.

  20. Robotics Intern Retrofits Home Appliance to Operate in New, More-Efficient

    Science.gov Websites

    Ways | News | NREL Robotics Intern Retrofits Home Appliance to Operate in New, More-Efficient Ways Robotics Intern Retrofits Home Appliance to Operate in New, More-Efficient Ways November 2, 2017 Energy's Energy Efficiency and Renewable Energy Robotics Internship Program. Photo courtesy of Jamie Santos

  1. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Societymore » for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.« less

  2. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency watermore » heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  3. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  4. 78 FR 9936 - Federal Housing Administration (FHA): PowerSaver Home Energy Retrofit Loan Pilot Program...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-12

    ... Administration (FHA): PowerSaver Home Energy Retrofit Loan Pilot Program: Extension of Pilot Program AGENCY...: On March 31, 2011, HUD published a notice that announced HUD's FHA Home Energy Retrofit Loan Pilot Program (Retrofit Pilot Program) known as FHA PowerSaver, which is a pilot program conducted for loans...

  5. Need for Systematic Retrofit Analysis in Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malhotra, Mini; Im, Piljae

    2014-01-01

    Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets ofmore » measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.« less

  6. Lighting retrofits at the Pittsburgh Zoo and Aviary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sadowski, E.C.

    Energy bills for the Pittsburgh Zoo typically total $280,000 a year, of which about $220,000 are spent on electricity. Until recently, lighting accounted for 20 percent of this electricity use. This translated into an annual cost of $44,000. Recent advances in lighting technology have made it possible to perform lighting retrofits in Zoo facilities that reduce energy costs while also providing improved light quality and better lit and more natural looking exhibits and animal holding areas. Through an investment of $127,690 in these projects from mid-1992 through mid-1994, the Zoo expects to realize an annual savings in electricity costs ofmore » $24,500 and further savings from a reduction in maintenance and plant replacement costs. Retrofits to the lighting systems in the Tropical Forest Building, the Aquarium, and the Niches of the World Building were the most interesting and are described in detail. Providing a sufficient amount of ultraviolet light to maintain the health of reptiles was a particular challenge in the Niches of the World Building. Lack of separate meters and additions to the Zoo have made the determination of the actual performance of these retrofit projects impossible. A similar retrofit project at the Pittsburgh Aviary (now the National Aviary) in 1989 through 1990 provides savings figures that should be comparable to those expected at the Zoo, however. This project cost $100,000 and saved $21,008 in electricity costs during the first year of operation. Maintenance costs were reduced by approximately $5000 a year.« less

  7. Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ARBI

    2014-09-01

    The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared tomore » the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.« less

  8. Life cycle cost-based risk model for energy performance contracting retrofits

    NASA Astrophysics Data System (ADS)

    Berghorn, George H.

    Buildings account for 41% of the primary energy consumption in the United States, nearly half of which is accounted for by commercial buildings. Among the greatest energy users are those in the municipalities, universities, schools, and hospitals (MUSH) market. Correctional facilities are in the upper half of all commercial building types for energy intensity. Public agencies have experienced reduced capital budgets to fund retrofits; this has led to the increased use of energy performance contracts (EPC), which are implemented by energy services companies (ESCOs). These companies guarantee a minimum amount of energy savings resulting from the retrofit activities, which in essence transfers performance risk from the owner to the contractor. Building retrofits in the MUSH market, especially correctional facilities, are well-suited to EPC, yet despite this potential and their high energy intensities, efficiency improvements lag behind that of other public building types. Complexities in project execution, lack of support for data requests and sub-metering, and conflicting project objectives have been cited as reasons for this lag effect. As a result, project-level risks must be understood in order to support wider adoption of retrofits in the public market, in particular the correctional facility sub-market. The goal of this research is to understand risks related to the execution of energy efficiency retrofits delivered via EPC in the MUSH market. To achieve this goal, in-depth analysis and improved understanding was sought with regard to ESCO risks that are unique to EPC in this market. The proposed work contributes to this understanding by developing a life cycle cost-based risk model to improve project decision making with regard to risk control and reduction. The specific objectives of the research are: (1) to perform an exploratory analysis of the EPC retrofit process and identify key areas of performance risk requiring in-depth analysis; (2) to construct a

  9. 75 FR 18160 - Small Takes of Marine Mammals Incidental to Specified Activities; Antioch Bridge Seismic Retrofit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-09

    ... of Marine Mammals Incidental to Specified Activities; Antioch Bridge Seismic Retrofit Project... pile driving associated with the Antioch Bridge Seismic Retrofit Project. DATES: Effective August 15... request from Caltrans to harass marine mammals incidental to the Antioch Bridge Seismic Retrofit Project...

  10. Retrofitting the Low Impact Development Practices into Developed Urban areas Including Barriers and Potential Solution

    NASA Astrophysics Data System (ADS)

    Shafique, Muhammad; Kim, Reeho

    2017-06-01

    Low impact development (LID)/green infrastructure (GI) practices have been identified as the sustainable practices of managing the stormwater in urban areas. Due to the increasing population, most of the cities are more developing which results in the change of natural area into impervious areas (roads, buildings etc.). Moreover, urbanization and climate change are causing many water-related problems and making over cities unsafe and insecure. Under these circumstances, there is a need to introduce new stormwater management practices into developed cities to reduce the adverse impacts of urbanization. For this purpose, retrofitting low impact development practices demands more attention to reduce these water-related problems and trying to make our cities sustainable. In developed areas, there is a little space is available for the retrofitting of LID practices for the stormwater management. Therefore, the selection of an appropriate place to retrofitting LID practices needs more concern. This paper describes the successfully applied retrofitting LID practices around the globe. It also includes the process of applying retrofitting LID practices at the suitable place with the suitable combination. Optimal places for the retrofitting of different LID practices are also mentioned. This paper also highlights the barriers and potential solutions of retrofitting LID practices in urban areas.

  11. Field Assessment of Energy Audit Tools for Retrofit Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, J.; Bohac, D.; Nelson, C.

    2013-07-01

    This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home’s energy performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Rating systems based on energy performance models, the focus of this report, can establish a home’s achievable energy efficiency potential and provide a quantitative assessment of energy savings after retrofits are completed, although their accuracy needs to be verified by actual measurement or billing data. Ratings can also showmore » homeowners where they stand compared to their neighbors, thus creating social pressure to conform to or surpass others. This project field-tested three different building performance models of varying complexity, in order to assess their value as rating systems in the context of a residential retrofit program: Home Energy Score, SIMPLE, and REM/Rate.« less

  12. Motel DHW Retrofit--Dallas, Texas

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Solar-energy system designed to provide 65% of total domestic-hot-water (DHW) demands for 100-room motel in Dallas, Texas is subject of a report now available. System is retrofit, and storage-tank size was limited to 1,000 gallons (3,785 1) by size of room where it is located.

  13. Retrofit Audits and Cost Estimates. A Look at Quality and Consistency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eisenberg, L.; Shapiro, C.; Fleischer, W.

    Retrofit NYC Block by Block is an outreach program targeting owners of one- to four-family homes, the most common building type in New York City, with more than 600,000 structures citywide. Administered by the Pratt Center for Community Development and implemented by four nonprofit, community-based organizations, Block by Block connects residents, businesses, and religious and civic organizations in predominantly low-and moderate-income neighborhoods with one or more of a half-dozen public and private financial incentive programs that facilitate energy-efficiency retrofits. This research project sought to evaluate the approach, effectiveness, and the energy use reductions accomplished by the Retrofit NYC: Block bymore » Block program.« less

  14. Retrofit Audits and Cost Estimates: A Look at Quality and Consistency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eisenberg, L.; Shapiro, C.; Fleischer, W.

    Retrofit NYC Block by Block is an outreach program targeting owners of one- to four-family homes, the most common building type in New York City, with more than 600,000 structures citywide. Administered by the Pratt Center for Community Development and implemented by four nonprofit, community based organizations, Block by Block connects residents, businesses, and religious and civic organizations in predominantly low- and moderate-income neighborhoods with one or more of a half-dozen public and private financial incentive programs that facilitate energy-efficiency retrofits. This research project sought to evaluate the approach, effectiveness, and the energy use reductions accomplished by the Retrofit NYC:more » Block by Block program.« less

  15. Nine Steps to a Successful Lighting Retrofit.

    ERIC Educational Resources Information Center

    Ries, Jack

    1998-01-01

    Presents the steps needed to successfully design a lighting retrofit of school classrooms. Tips cover budgeting, technology, financing, contractor selection, assessing area function, and choosing a light source. (GR)

  16. Existing Whole-House Solutions Case Study: Retrofitting a 1960s Split-Level Cold-Climate Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puttagunta, S.

    2015-08-01

    National programs such as Home Performance with ENERGY STAR® and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usagemore » in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions.« less

  17. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  18. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  19. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  20. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  1. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  2. Dowel bar retrofit performance in Wisconsin.

    DOT National Transportation Integrated Search

    2010-05-01

    In 1999, WisDOT constructed test sections on I-39 to evaluate the dowel bar retrofit (DBR) rehabilitation technique for faulted concrete pavement slabs. Two years later, mortar deterioration and debonding were noted in the dowel slots. In response to...

  3. Expert Meeting Report. Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Van Straaten, R.

    2012-02-01

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  4. Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Van Straaten, R.

    2012-02-01

    The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011 at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

  5. Benchmarking Tool Kit.

    ERIC Educational Resources Information Center

    Canadian Health Libraries Association.

    Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…

  6. The integration of quantitative information with an intelligent decision support system for residential energy retrofits

    NASA Astrophysics Data System (ADS)

    Mo, Yunjeong

    The purpose of this research is to support the development of an intelligent Decision Support System (DSS) by integrating quantitative information with expert knowledge in order to facilitate effective retrofit decision-making. To achieve this goal, the Energy Retrofit Decision Process Framework is analyzed. Expert system shell software, a retrofit measure cost database, and energy simulation software are needed for developing the DSS; Exsys Corvid, the NREM database and BEopt were chosen for implementing an integration model. This integration model demonstrates the holistic function of a residential energy retrofit system for existing homes, by providing a prioritized list of retrofit measures with cost information, energy simulation and expert advice. The users, such as homeowners and energy auditors, can acquire all of the necessary retrofit information from this unified system without having to explore several separate systems. The integration model plays the role of a prototype for the finalized intelligent decision support system. It implements all of the necessary functions for the finalized DSS, including integration of the database, energy simulation and expert knowledge.

  7. Survival Kit - Food Kit

    NASA Image and Video Library

    1962-10-01

    S62-08743 (1962) --- Food kit used by Mercury astronauts. Some is dehydrated and needs water, other packets are ready to eat. Size is measured relative to a ruler. Included are packets of mushroom soup, orange-grapefruit juice, cocoa beverage, pineapple juice, chicken with gravy, pears, strawberries, beef and vegetables and other assorted food containers. Photo credit: NASA

  8. Survival Kit - Food Kit

    NASA Image and Video Library

    1962-10-01

    S62-08742 (1962) --- Food kit used by Mercury astronauts. Some is dehydrated and needs water, other packets are ready to eat. Size is measured relative to a ruler. Included are packets of mushroom soup, orange-grapefruit juice, cocoa beverage, pineapple juice, chicken with gravy, pears, strawberries, beef and vegetables and other assorted food containers. Photo credit: NASA

  9. Determinants of Household Water Conservation Retrofit Activity: A Discrete Choice Model Using Survey Data

    NASA Astrophysics Data System (ADS)

    Cameron, T. A.; Wright, M. B.

    1990-02-01

    Economic analyses of residential water demand have typically concentrated on price and income elasticities. In the short run a substantial change in water prices might induce only small changes in consumption levels. As time passes, however, households will have the opportunity to "retrofit" existing water-using equipment to make it less water-intensive. This produces medium- to long-run demand elasticities that are higher than short-run studies suggest. We examine responses to water conservation questions appearing on the Los Angeles Department of Water and Power's 1983 residential energy survey. We find that households' decisions to install shower retrofit devices are influenced by the potential to save money on water heating bills. We attribute toilet retrofit decisions more to noneconomic factors which might be characterized as "general conservation mindedness." The endogeneity of these retrofit decisions casts some doubt on the results of studies of individual households that treat voluntary retrofits as exogenous.

  10. A benefit-cost analysis of retrofitting diesel vehicles with particulate filters in the Mexico City metropolitan area.

    PubMed

    Stevens, Gretchen; Wilson, Andrew; Hammitt, James K

    2005-08-01

    In the Mexico City metropolitan area, poor air quality is a public health concern. Diesel vehicles contribute significantly to the emissions that are most harmful to health. Harmful diesel emissions can be reduced by retrofitting vehicles with one of several technologies, including diesel particulate filters. We quantified the social costs and benefits, including health benefits, of retrofitting diesel vehicles in Mexico City with catalyzed diesel particulate filters, actively regenerating diesel particulate filters, or diesel oxidation catalysts, either immediately or in 2010, when capital costs are expected to be lower. Retrofit with either type of diesel particulate filter or an oxidation catalyst is expected to provide net benefits to society beginning immediately and in 2010. At current prices, retrofit with an oxidation catalyst provides greatest net benefits. However, as capital costs decrease, retrofit with diesel particulate filters is expected to provide greater net benefits. In both scenarios, retrofit of older, dirtier vehicles that circulate only within the city provides greatest benefits, and retrofit with oxidation catalysts provides greater health benefits per dollar spent than retrofit with particulate filters. Uncertainty about the magnitude of net benefits of a retrofit program is significant. Results are most sensitive to values used to calculate benefits, such as the concentration-response coefficient, intake fraction (a measure of exposure), and the monetary value of health benefits.

  11. Assessment of cockpit interface concepts for data link retrofit

    NASA Technical Reports Server (NTRS)

    Mccauley, Hugh W.; Miles, William L.; Dwyer, John P.; Erickson, Jeffery B.

    1992-01-01

    The problem is examined of retrofitting older generation aircraft with data link capability. The approach taken analyzes requirements for the cockpit interface, based on review of prior research and opinions obtained from subject matter experts. With this background, essential functions and constraints for a retrofit installation are defined. After an assessment of the technology available to meet the functions and constraints, candidate design concepts are developed. The most promising design concept is described in detail. Finally, needs for further research and development are identified.

  12. Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyons, J.; Moore, M.; Thompson, M.

    2013-08-01

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative tomore » pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.« less

  13. Data and Analytics to Inform Energy Retrofit of High Performance Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Tianzhen; Yang, Le; Hill, David

    Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energymore » audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4

  14. Vulnerability assessment of medieval civic towers as a tool for retrofitting design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casciati, Sara; Faravelli, Lucia

    2008-07-08

    The seismic vulnerability of an ancient civic bell-tower is studied. Rather than seeing it as an intermediate stage toward a risk analysis, the assessment of vulnerability is here pursued for the purpose of optimizing the retrofit design. The vulnerability curves are drawn by carrying out a single time history analysis of a model calibrated on the basis of experimental data. From the results of this analysis, the medians of three selected performance parameters are estimated, and they are used to compute, for each of them, the probability of exceeding or attaining the three corresponding levels of light, moderate and severemore » damage. The same numerical model is then used to incorporate the effects of several retrofitting solutions and to re-estimate the associated vulnerability curves. The ultimate goal is to provide a numerical tool able to drive the optimization process of a retrofit design by the comparison of the vulnerability estimates associated with the different retrofitting solutions.« less

  15. Retrofitting solutions for two different occupancy levels of educational buildings in tropics

    NASA Astrophysics Data System (ADS)

    Yang, Junjing; Pantazaras, Alexandros; Lee, Siew Eang; Santamouris, Mattheos

    2018-01-01

    Within the multi-functionality of educational buildings, the energy conservation potential can be very different. In addition, among different retrofitting solutions investigated involving interventions on the building envelope, ventilation strategies, artificial lighting systems as well as equipment upgrading, different saving potential would come from different aspects. The opportunities for energy saving potential from the overall point of view and from the detailed aspect view of different retrofitting solutions would be very useful and important for building renovation decision making. This study presents a detailed retrofitting study of two different educational buildings. One represents a building with average occupancy variation and containing mainly offices and labs. The other one represents a building with high occupancy variation and containing mainly lecture rooms and studios. This comparison of the results gives an idea of the different energy saving potential for different types of educational buildings. Principal component analysis is also adopted to investigate the detailed performance of one of the buildings which is influenced stronger by these retrofitting solutions.

  16. Technology Solutions for Existing Homes Overview: Quantifying the Financial Benefits of Multifamily Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-04-01

    In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit (PARR) worked with Elevate Energy on three tasks: to conduct pre- and post-retrofit analysis on the income and expense data of 13 Chicago-area multifamily buildings, to compare Chicago income and expense data to two national samples, and to explore the ramifications that energy-efficiency retrofits have on nine Chicago-area neighborhoods. The project team collected building, energy, and income and expense data from multiple private and public sources.

  17. Life cycle assessment: Existing building retrofit versus replacement

    NASA Astrophysics Data System (ADS)

    Darabi, Nura

    The embodied energy in building materials constitutes a large part of the total energy required for any building (Thormark 2001, 429). In working to make buildings more energy efficient this needs to be considered. Integrating considerations about life cycle assessment for buildings and materials is one promising way to reduce the amount of energy consumption being used within the building sector and the environmental impacts associated with that energy. A life cycle assessment (LCA) model can be utilized to help evaluate the embodied energy in building materials in comparison to the buildings operational energy. This thesis takes into consideration the potential life cycle reductions in energy and CO2 emissions that can be made through an energy retrofit of an existing building verses demolition and replacement with a new energy efficient building. A 95,000 square foot institutional building built in the 1960`s was used as a case study for a building LCA, along with a calibrated energy model of the existing building created as part of a previous Masters of Building Science thesis. The chosen case study building was compared to 10 possible improvement options of either energy retrofit or replacement of the existing building with a higher energy performing building in order to see the life cycle relationship between embodied energy, operational energy, and C02 emissions. As a result of completing the LCA, it is shown under which scenarios building retrofit saves more energy over the lifespan of the building than replacement with new construction. It was calculated that energy retrofit of the chosen existing institutional building would reduce the amount of energy and C02 emissions associated with that building over its life span.

  18. 75 FR 21016 - Notice of Proposed Information Collection: Comment Request; The Green Retrofit Program of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-22

    ... Information Collection: Comment Request; The Green Retrofit Program of the American Recovery and... Retrofit Program authorized by the American Recovery and Revitalization Act of 2009. The legislation.... The Green Retrofit Program is detailed in HUD Notice H 09-02 issued on May 13, 2009. This Notice is...

  19. Adaptation of commercial biomarker kits and proposal for 'drug development kits' to support bioanalysis: call for action.

    PubMed

    Islam, Rafiqul; Kar, Sumit; Islam, Clarinda; Farmen, Raymond

    2018-06-01

    There has been an increased use of commercial kits for biomarker measurement, commensurate with the increased demand for biomarkers in drug development. However, in most cases these kits do not meet the quality attributes for use in regulated environment. The process for adaptation of these kits can be frustrating, time consuming and resource intensive. In addition, a lack of harmonized guidance for the validation of biomarker poses a significant challenge in the adaptation of kits in a regulated environment. The purpose of this perspective is to propose a tiered approach to commercial drug development kits with clearly defined quality attributes and to demonstrate how these kits can be adapted to perform analytical validation in a regulated environment.

  20. Low-E Retrofit Demonstration and Educational Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culp, Thomas D; Wiehagen, Joseph; Drumheller, S Craig

    The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment airmore » leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low

  1. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    PubMed

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  2. Optimizing Medical Kits for Spaceflight

    NASA Technical Reports Server (NTRS)

    Keenan, A. B,; Foy, Millennia; Myers, G.

    2014-01-01

    The Integrated Medical Model (IMM) is a probabilistic model that estimates medical event occurrences and mission outcomes for different mission profiles. IMM simulation outcomes describing the impact of medical events on the mission may be used to optimize the allocation of resources in medical kits. Efficient allocation of medical resources, subject to certain mass and volume constraints, is crucial to ensuring the best outcomes of in-flight medical events. We implement a new approach to this medical kit optimization problem. METHODS We frame medical kit optimization as a modified knapsack problem and implement an algorithm utilizing a dynamic programming technique. Using this algorithm, optimized medical kits were generated for 3 different mission scenarios with the goal of minimizing the probability of evacuation and maximizing the Crew Health Index (CHI) for each mission subject to mass and volume constraints. Simulation outcomes using these kits were also compared to outcomes using kits optimized..RESULTS The optimized medical kits generated by the algorithm described here resulted in predicted mission outcomes more closely approached the unlimited-resource scenario for Crew Health Index (CHI) than the implementation in under all optimization priorities. Furthermore, the approach described here improves upon in reducing evacuation when the optimization priority is minimizing the probability of evacuation. CONCLUSIONS This algorithm provides an efficient, effective means to objectively allocate medical resources for spaceflight missions using the Integrated Medical Model.

  3. Assessment and evaluation of timber piles used in Nebraska for retrofit and rating.

    DOT National Transportation Integrated Search

    2014-04-01

    The cost of an effective retrofitting and rehabilitation of timber piles is less than cost of replacing the piles. However, some of the retrofit options used in Nebraska failed to result in the expected performance levels. Further, design and detaili...

  4. Before and after retrofit - response of a building during ambient and strong motions

    USGS Publications Warehouse

    Celebi, M.; Liu, Huaibao P.; ,

    1998-01-01

    This paper presents results obtained from ambient vibration and strong-motion responses of a thirteen-story, moment-resisting steel framed Santa Clara County Office Building (SCCOB) before being retrofitted by visco-elastic dampers and from ambient vibration response following the retrofit. Understanding the cumulative structural and site characteristics that affect the response of SCCOB before and after the retrofit is important in assessing earthquake hazards to other similar buildings and decision making in retrofitting them. The results emphasize the need to better evaluate structural and site characteristics in developing earthquake resisting designs that avoid resonating effects. Various studies of the strong-motion response records from the SCCOB during the 24 April 1984 (MHE) Morgan Hill (MS = 6.1), the 31 March 1986 (MLE) Mt. Lewis (MS = 6.1) and the 17 October 1989 (LPE) Loma Prieta (MS = 7.1) earthquakes show that the dynamic characteristics of the building are such that it (a) resonated (b) responded with a beating effect due to close-coupling of its translational and torsional frequencies, and (c) had a long-duration response due to low-damping. During each of these earthquakes, there was considerable contents damage and the occupants felt the rigorous vibration of the building. Ambient tests of SCCOB performed following LPE showed that both translational and torsional periods of the building are smaller than those derived from strong motions. Ambient tests performed following the retrofit of the building with visco-elastic dampers show that the structural fundamental mode frequency of the building has increased. The increased frequency implies a stiffer structure. Strong-motion response of the building during future earthquakes will ultimately validate the effectiveness of the retrofit method.This paper presents results obtained from ambient vibration and strong-motion responses of a thirteen-story, moment-resisting steel framed Santa Clara County

  5. Modeling the resiliency of energy-efficient retrofits in low-income multifamily housing.

    PubMed

    Underhill, L J; Fabian, M P; Vermeer, K; Sandel, M; Adamkiewicz, G; Leibler, J H; Levy, J I

    2018-05-01

    Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures' impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM 2.5 and NO 2 in a low-income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low- and high-emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM 2.5 or NO 2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy-efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost-effective, widespread benefits. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Evaluation of tyrosine-kinase receptor c-KIT (c-KIT) mutations, mRNA and protein expression in canine leukemia: might c-KIT represent a therapeutic target?

    PubMed

    Giantin, M; Aresu, L; Aricò, A; Gelain, M E; Riondato, F; Martini, V; Comazzi, S; Dacasto, M

    2013-04-15

    The tyrosine-kinase receptor c-KIT (c-KIT) plays an important role in proliferation, survival and differentiation of progenitor cells in normal hematopoietic cells. In human hematological malignancies, c-KIT is mostly expressed by progenitor cell neoplasia and seldom by those involving mature cells. Tyrosine kinase inhibitors (TKIs) are actually licensed for the first- and second-line treatment of human hematologic disorders. Aim of the present study was to evaluate c-KIT mRNA and protein expression and complementary DNA (cDNA) mutations in canine leukemia. Eleven acute lymphoblastic leukemia (ALL) and acute undifferentiated leukemia (AUL) and 12 chronic lymphocytic leukemia (CLL) were enrolled in this study. The amounts of c-KIT mRNA and protein were determined, in peripheral blood samples, by using quantitative real time RT-PCR, flow cytometry and immunocytochemistry, respectively. The presence of mutations on c-KIT exons 8-11 and 17 were investigated by cDNA sequencing. Higher amounts of c-KIT mRNA were found in ALL/AUL compared to CLL, and this latter showed a lower pattern of gene expression. Transcriptional data were confirmed at the protein level. No significant gain-of-function mutations were ever observed in both ALL/AUL and CLL. Among canine hematological malignancies, ALL/AUL typically show a very aggressive biological behavior, partly being attributable to the lack of efficacious therapeutic options. The high level of c-KIT expression found in canine ALL/AUL might represent the rationale for using TKIs in future clinical trials. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. School Retrofit Design Analysis System. A Microcomputer Model for School Energy Use.

    ERIC Educational Resources Information Center

    Canipe, Stephen Lee

    The School Retrofit Design Analysis System (SRDAS) developed in this study provides a non-technical method for the school administrator to use in evaluating alternative energy saving retrofit and new construction design possibilities. By providing a high degree of flexibility, SRDAS is applicable to a wide range of school building and retrofit…

  8. Facilities Upgrade and Retrofit. Strategies for Success.

    ERIC Educational Resources Information Center

    Kennedy, Mike

    2000-01-01

    Provides three articles on the subject of educational facility upgrading and retrofiting that address setting guidelines for classroom acoustics, making sports facilities brighter and more energy-efficient, and cutting energy bills and protecting interiors. (GR)

  9. Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Podorson, David

    Exterior insulation and finish systems (EIFS) are proprietary synthetic formulations that are applied to the exterior walls of buildings to serve as insulation and exterior cladding. The insulation thickness can vary from less than one inch to a foot or more. In this project the applicability of EIFS for residential deep energy retrofits was investigated through modeling and a case study home. The home was retrofitted using a site-applied four-inch-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS system were documented. The demonstration home was modeled using Buildingmore » Energy Optimization energy and cost analysis software to explore cost effectiveness of various EIFS insulation thicknesses in two climate locations.« less

  10. Education Payload Operation - Kit D

    NASA Technical Reports Server (NTRS)

    Keil, Matthew

    2009-01-01

    Education Payload Operation - Kit D (EPO-Kit D) includes education items that will be used to support the live International Space Station (ISS) education downlinks and Education Payload Operation (EPO) demonstrations onboard the ISS. The main objective of EPO-Kit D supports the National Aeronautics and Space Administration (NASA) goal of attracting students to study and seek careers in science, technology, engineering, and mathematics.

  11. Cardiac c-Kit Biology Revealed by Inducible Transgenesis.

    PubMed

    Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A

    2018-06-22

    Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart

  12. 76 FR 17936 - Federal Housing Administration (FHA): Notice of FHA PowerSaver Home Energy Retrofit Loan Pilot...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-31

    ... Housing Administration (FHA): Notice of FHA PowerSaver Home Energy Retrofit Loan Pilot Program AGENCY...: Notice. SUMMARY: This notice announces HUD's FHA Home Energy Retrofit Loan Pilot Program (Retrofit Pilot... to conduct an Energy Efficient Mortgage Innovation pilot program targeted to the single family...

  13. Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gates, C.; Neuhauser, K.

    2014-03-01

    Between December, 2009 and December, 2012, 42 deep energy retrofit (DER) projects were completed through a pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. Thirty-seven of these projects were comprehensive retrofits while five were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. Building Science Corporation developed a consistent "package" of measures in terms of the performance targeted for major building components. Based on the community experience, this DER package is expected to result in yearly source energy use near 110more » MMBtu/year or approximately 40% below the Northeast regional average.« less

  14. Integrated Framework for Patient Safety and Energy Efficiency in Healthcare Facilities Retrofit Projects.

    PubMed

    Mohammadpour, Atefeh; Anumba, Chimay J; Messner, John I

    2016-07-01

    There is a growing focus on enhancing energy efficiency in healthcare facilities, many of which are decades old. Since replacement of all aging healthcare facilities is not economically feasible, the retrofitting of these facilities is an appropriate path, which also provides an opportunity to incorporate energy efficiency measures. In undertaking energy efficiency retrofits, it is vital that the safety of the patients in these facilities is maintained or enhanced. However, the interactions between patient safety and energy efficiency have not been adequately addressed to realize the full benefits of retrofitting healthcare facilities. To address this, an innovative integrated framework, the Patient Safety and Energy Efficiency (PATSiE) framework, was developed to simultaneously enhance patient safety and energy efficiency. The framework includes a step -: by -: step procedure for enhancing both patient safety and energy efficiency. It provides a structured overview of the different stages involved in retrofitting healthcare facilities and improves understanding of the intricacies associated with integrating patient safety improvements with energy efficiency enhancements. Evaluation of the PATSiE framework was conducted through focus groups with the key stakeholders in two case study healthcare facilities. The feedback from these stakeholders was generally positive, as they considered the framework useful and applicable to retrofit projects in the healthcare industry. © The Author(s) 2016.

  15. DIESEL ENGINE RETROFIT TECHNOLOGY VERIFICATION (POSTER)

    EPA Science Inventory

    ETV is presenting a poster at the EPA's 2005 Science Forum from May 16-18, 2005 in Washington, DC. This poster will contain a summary of the performance results realized by the six verified diesel retrofit technologies, as well as potential impacts that could be realized if sigi...

  16. Molecular Alterations of KIT Oncogene in Gliomas

    PubMed Central

    Gomes, Ana L.; Reis-Filho, Jorge S.; Lopes, José M.; Martinho, Olga; Lambros, Maryou B. K.; Martins, Albino; Schmitt, Fernando; Pardal, Fernando; Reis, Rui M.

    2007-01-01

    Gliomas are the most common and devastating primary brain tumours. Despite therapeutic advances, the majority of gliomas do not respond either to chemo or radiotherapy. KIT, a class III receptor tyrosine kinase (RTK), is frequently involved in tumourigenic processes. Currently, KIT constitutes an attractive therapeutic target. In the present study we assessed the frequency of KIT overexpression in gliomas and investigated the genetic mechanisms underlying KIT overexpression. KIT (CD117) immunohistochemistry was performed in a series of 179 gliomas of various grades. KIT activating gene mutations (exons 9, 11, 13 and 17) and gene amplification analysis, as defined by chromogenic in situ hybridization (CISH) and quantitative real-time PCR (qRT-PCR) were performed in CD117 positive cases. Tumour cell immunopositivity was detected in 15.6% (28/179) of cases, namely in 25% (1/4) of pilocytic astrocytomas, 25% (5/20) of diffuse astrocytomas, 20% (1/5) of anaplastic astrocytomas, 19.5% (15/77) of glioblastomas and one third (3/9) of anaplastic oligoastrocytomas. Only 5.7% (2/35) of anaplastic oligodendrogliomas showed CD117 immunoreactivity. No association was found between tumour CD117 overexpression and patient survival. In addition, we also observed CD117 overexpression in endothelial cells, which varied from 0–22.2% of cases, being more frequent in high-grade lesions. No KIT activating mutations were identified. Interestingly, CISH and/or qRT-PCR analysis revealed the presence of KIT gene amplification in 6 glioblastomas and 2 anaplastic oligoastrocytomas, corresponding to 33% (8/24) of CD117 positive cases. In conclusion, our results demonstrate that KIT gene amplification rather than gene mutation is a common genetic mechanism underlying KIT expression in subset of malignant gliomas. Further studies are warranted to determine whether glioma patients exhibiting KIT overexpression and KIT gene amplification may benefit from therapy with anti-KIT RTK inhibitors. PMID

  17. Seismic retrofit guidelines for Utah highway bridges.

    DOT National Transportation Integrated Search

    2009-05-01

    Much of Utahs population dwells in a seismically active region, and many of the bridges connecting transportation lifelines predate the rigorous seismic design standards that have been developed in the past 10-20 years. Seismic retrofitting method...

  18. Multifamily Retrofit Project Manager Job/Task Analysis and Report: September 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, C. M.

    The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Retrofit Project Manager JTA identifies and catalogs all of the tasks performed by multifamily retrofit project managers, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

  19. KIT Mutations Are Common in Testicular Seminomas

    PubMed Central

    Kemmer, Kathleen; Corless, Christopher L.; Fletcher, Jonathan A.; McGreevey, Laura; Haley, Andrea; Griffith, Diana; Cummings, Oscar W.; Wait, Cecily; Town, Ajia; Heinrich, Michael C.

    2004-01-01

    Expression of KIT tyrosine kinase is critical for normal germ cell development and is observed in the majority of seminomas. Activating mutations in KIT are common in gastrointestinal stromal tumors and mastocytosis. In this study we examined the frequency and spectrum of KIT mutations in 54 testicular seminomas, 1 ovarian dysgerminoma and 37 non-seminomatous germ cell tumors (NSGCT). Fourteen seminomas (25.9%) contained exon 17 point mutations including D816V (6 cases), D816H (3 cases), Y823D (2 cases), and single examples of Y823C, N822K, and T801I. No KIT mutations were found in the ovarian dysgerminoma or the NSGCTs. In transient transfection assays, mutant isoforms D816V, D816H, Y823D, and N822K were constitutively phosphorylated in the absence of the natural ligand for KIT, stem cell factor (SCF). In contrast, activation of T801I and wild-type KIT required SCF. Mutants N822K and Y823D were inhibited by imatinib mesylate (Gleevec, previously STI571) whereas D816V and D816H were both resistant to imatinib mesylate. Biochemical evidence of KIT activation, as assessed by KIT phosphorylation and KIT association with phosphatidylinositol (PI) 3-kinase in tumor cell lysates, was largely confined to seminomas with a genomic KIT mutation. These findings suggest that activating KIT mutations may contribute to tumorigenesis in a subset of seminomas, but are not involved in NSGCT. PMID:14695343

  20. Quantifying the benefits of a building retrofit using an integrated system approach: A case study

    DOE PAGES

    Regnier, Cynthia; Sun, Kaiyu; Hong, Tianzhen; ...

    2017-11-11

    Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimummore » code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.« less

  1. Quantifying the benefits of a building retrofit using an integrated system approach: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regnier, Cynthia; Sun, Kaiyu; Hong, Tianzhen

    Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimummore » code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.« less

  2. Retrofitting tractors with rollover protective structures: perspective of equipment dealers.

    PubMed

    Tonelli, S M; Donham, K J; Leedom-Larson, K; Sanderson, W; Purschwitz, M

    2009-10-01

    This study was one of a cluster of studies that originated via requests for proposals from the NIOSH National Agricultural Tractor Safety Initiative. The present study design consisted of several steps: (1) formation of an advisory group, (2) development and testing of a standard paper self-responding survey instrument, (3) sample selection of farm equipment dealers, (4) administration of the survey, (5) assessment and analysis of the survey, and (6) in-person response panel of dealers (n = 80) to review results of the questionnaire for further definition and sharpening of the recommendations from the survey. A key finding is that most dealers do not currently sell or install ROPS retrofit kits. Barriers cited by dealers included (1) actual or perceived lack of farmer demand, (2) injury liability, (3) expensive freight for ordering ROPS, (4) lack of dealer awareness of the magnitude of deaths from tractor overturns and the high life-protective factor of ROPS, and (5) difficulty and incursion of non-recoverable expenses in locating and obtaining specific ROPS. Despite not currently selling or installing ROPS, dealers responded favorably about their future potential role in ROPS promotion and sales. Dealers were willing to further promote, sell, and install ROPS if there was demand from farmers. Recommendations include establishing a ROPS "clearing house" that dealers could contact to facilitate locating and obtaining ROPS orders from customers. Additional recommendations include education and social marketing targeting farm machinery dealers as well farmers, manufacturers, and policy makers.

  3. 49 CFR 214.513 - Retrofitting of existing on-track roadway maintenance machines; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Retrofitting of existing on-track roadway maintenance machines; general. 214.513 Section 214.513 Transportation Other Regulations Relating to... SAFETY On-Track Roadway Maintenance Machines and Hi-Rail Vehicles § 214.513 Retrofitting of existing on...

  4. Building America Case Study: Quantifying the Financial Benefits of Multifamily Retrofits, Chicago, Illinois

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Increasing the adoption of energy efficient building practices will require the energy sector to increase their understanding of the way that retrofits affect multifamily financial performance as well as how those indicators are interpreted by the lending and appraisal industries. This project analyzed building, energy, and financial program data as well as other public and private data to examine the relationship between energy efficiency retrofits and financial performance on three levels: building, city, and community. The project goals were to increase the data and analysis in the growing body of multifamily financial benefits work as well provide a framework formore » other geographies to produce similar characterization. The goals are accomplished through three tasks: Task one: A pre- and post-retrofit analysis of thirteen Chicago multifamily buildings. Task two: A comparison of Chicago income and expenses to two national datasets. Task three: An in-depth look at multifamily market sales data and the subsequent impact of buildings that undergo retrofits.« less

  5. Examining non-structural retrofitting status of teaching hospitals in Kerman against disasters.

    PubMed

    Moghadam, Mahmood Nekooi; Moradi, Seyed Mobin; Amiresmaili, Mohammadreza

    2017-05-01

    Continuous services provision of a hospital before and after a disaster is one of the most prominent issues that all people, especially the authorities must take into huge consideration. Concerning the experiences of previous earthquakes, the role and importance of nonstructural components becomes increasingly clear in the uninterrupted services of hospitals. In this study, non-structural retrofitting status of Kerman teaching hospitals was evaluated against natural disasters. This cross-sectional study was carried out in the second half of 2014 on the teaching hospitals in Kerman (Iran). The study population consisted of all Kerman teaching hospitals. The research instrument was World Health Organization/Pan American Health Organization (WHO/PAHO) standard checklist. Data analysis was carried out using descriptive statistics through SPSS 19. One hospital had a low retrofitting level, two hospitals had an average level and one had a high level. In the examined hospitals in this study, the medical gas section had the lowest preparedness against natural disasters, while the office, warehouse and furniture section had the highest resistance. Generally, the non-structural retrofitting status was 50% in one hospital and was between 65% and 85% in other hospitals. Generally, the retrofitting status of hospitals was not at the ideal condition, most hospitals were in average condition. Concerning the high risk of hospitals in disasters, it is necessary that senior executives and managers of Kerman Province and Kerman University of Medical Sciences take some measures to retrofit these buildings and to reduce the risk of vulnerability.

  6. Cold Climate and Retrofit Applications for Air-to-Air Heat Pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D

    2015-01-01

    Air source heat pumps (ASHP) including air-to-air ASHPs are easily applied to buildings almost anywhere for new construction as well as retrofits or renovations. They are widespread in milder climate regions but their use in cold regions is hampered due to low heating efficiency and capacity at cold outdoor temperatures. Retrofitting air-to-air ASHPs to existing buildings is relatively easy if the building already has an air distribution system. For buildings without such systems alternative approaches are necessary. Examples are ductless, minisplit heat pumps or central heat pumps coupled to small diameter, high velocity (SDHV) air distribution systems. This article presentsmore » two subjects: 1) a summary of R&D investigations aimed at improving the cold weather performance of ASHPs, and 2) a brief discussion of building retrofit options using air-to-air ASHP systems.« less

  7. A survey of some solar energy retrofits.

    DOT National Transportation Integrated Search

    1981-01-01

    The report briefly describes a survey of some solar energy retrofits, such as solar heaters and Trombe walls, that can be easily adapted into existing buildings belonging to the Department. With their relatively high cost, commercial solar heaters ha...

  8. Optics learning through affordable kit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P, Anusha N, E-mail: anushnp@gmail.com, E-mail: chitrashaji@gmail.com, E-mail: aloksharan@gmail.com; Shaji, Chitra, E-mail: anushnp@gmail.com, E-mail: chitrashaji@gmail.com, E-mail: aloksharan@gmail.com; Sharan, Alok, E-mail: anushnp@gmail.com, E-mail: chitrashaji@gmail.com, E-mail: aloksharan@gmail.com

    2014-10-15

    An affordable kit which helps to understand some of the optical phenomena qualitatively and quantitatively is presented in this paper. It supplements optics taught in classes. The kit consists of equipments which are available in the market at nominal cost such as laser pointer, lenses, glass plates, razor blades, coins, ball bearing etc. Experiments which come under wave optics (interference and diffraction) and ray optics (reflection and refraction) are explained using this kit.

  9. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... resin kits consisting of a base material component (Class 3, Packing Group II or III) and an activator...

  10. A systems evaluation on the effectiveness of a catalyst retrofit program in China.

    PubMed

    Jones, M; Wilson, R; Norbeck, J M; Han, W; Hurley, R; Schuetzle, D

    2001-09-01

    A low-cost, rare-earth oxide (REO) catalyst has been recommended as part of China's retrofit program for Chinese carbureted vehicles. This study evaluated: (1) the emission reduction efficiency of the REO catalyst during chassis dynamometer testing on the FTP cycle; (2) the effect that fuel properties had on tailpipe emissions and catalyst efficiency; (3) the importance of vehicle premaintenance as part of a retrofit protocol; and (4) the emission reductions obtained following implementation of the program. Results also show that current in-use Chinese noncatalyst, carbureted vehicles operate excessively rich, resulting in extremely high emissions of CO, gaseous toxic compounds, and other non-methane hydrocarbon species (NMHC). Preretrofit maintenance alone has the potential to reduce these emissions by approximately 50%. Dynamometer emission tests showed emissions reductions of >95% for hydrocarbons, CO, and gaseous toxics after retrofit of the REO catalyst. In particular, the relative unit health risk associated with the decrease in emissions of airborne toxic compounds using unleaded Chinese fuel was reduced from 6.33 to 0.30. (Use of low-sulfur California Phase II gasoline rather than current in-use Chinese fuel reduced emissions further.) Following implementation of the program, a follow-up study showed that in-use emissions benefits were considerably less than anticipated, primarily because of poor quality control at the retrofit service centers, a less aggressive preretrofit maintenance procedure, and unauthorized modification to the recommended retrofit control system. Overall results indicate that a carefully controlled retrofit program using REO catalyst technology can reduce emissions significantly. However, well-defined implementation guidelines, and strict adherence to these guidelines are needed to achieve maximum benefits.

  11. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a

  12. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have... publicizes its recognition of the first test kit that meets both the negative response and positive response...

  13. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  14. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  15. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  16. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  17. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  18. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  19. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  20. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  1. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  2. Transit safety retrofit package development : final report.

    DOT National Transportation Integrated Search

    2014-07-01

    This report provides a summary of the Transit Safety Retrofit Package (TRP) Development project and its results. The report documents results of each project phase, and provides recommended next steps as well as a vision for a next generation TRP. Th...

  3. Study on the application of ambient vibration tests to evaluate the effectiveness of seismic retrofitting

    NASA Astrophysics Data System (ADS)

    Liang, Li; Takaaki, Ohkubo; Guang-hui, Li

    2018-03-01

    In recent years, earthquakes have occurred frequently, and the seismic performance of existing school buildings has become particularly important. The main method for improving the seismic resistance of existing buildings is reinforcement. However, there are few effective methods to evaluate the effect of reinforcement. Ambient vibration measurement experiments were conducted before and after seismic retrofitting using wireless measurement system and the changes of vibration characteristics were compared. The changes of acceleration response spectrum, natural periods and vibration modes indicate that the wireless vibration measurement system can be effectively applied to evaluate the effect of seismic retrofitting. The method can evaluate the effect of seismic retrofitting qualitatively, it is difficult to evaluate the effect of seismic retrofitting quantitatively at this stage.

  4. The application, benefits and challenges of retrofitting the existing buildings

    NASA Astrophysics Data System (ADS)

    Khairi, Muhammad; Jaapar, Aini; Yahya, Zaharah

    2017-11-01

    Sustainable development has been the main topic of debate for years in some countries such as United Kingdom, United State of America and Malaysia. Depletion of natural resources, global warming, economics uncertainty and health issues are some of the reasons behind sustainable development movements, it is not just a political debate in the parliament but more towards collective works among sectors in order to minimizing the negative impact of development to the environment and other living organism. Retrofit an existing building is one of the solutions to reduce the dependency on constructing new buildings. There are huge numbers of existing building stocks that suitable to be retrofitted such as historical buildings, offices, residential, warehouse, factories, vacant buildings and other historical buildings. Therefore, the aim of this research is to provide information on the application, benefits and challenges of retrofitting an existing building. Two buildings were chosen as case studies following by site visits and observation to the buildings. The data were then compared in a table form. Primary and secondary sources were also used for this research. The application of retrofit should be promoted across the construction and conservation industries since it has significant tangible and intangible benefits. It is one of the most environmentally friendly and efficient solutions to optimize the energy performance and could also helps to extend the life of the existing building or historical buildings while ensuring optimum thermal comfort for the occupants which leads to higher productivity.

  5. Retrofitting: The Thermal Upgrading of Buildings.

    ERIC Educational Resources Information Center

    Maine Audubon Society, Falmouth.

    This publication is a compilation of talks delivered during the spring of 1977 by Charles Wing. Contents of the booklet include retrofitting old houses, condensation and vapor barriers, solutions to the vapor barrier problem, and how much of which insulation to use. The publication includes charts, drawings, and equations to illustrate the topics…

  6. Energy Retrofit Creates an Efficient Building.

    ERIC Educational Resources Information Center

    Freeman, Laurie

    1997-01-01

    After 20 years of inadequate heating and cooling, an Indiana school district took advantage of a 1994 state law that allows school districts to bypass the "low-bidder wins" restriction. The district established a guaranteed energy-saving contract for a climate-control-improvements package to retrofit the junior-senior high school. (MLF)

  7. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit... kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A...

  8. Megakaryocytes compensate for Kit insufficiency in murine arthritis.

    PubMed

    Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A

    2017-05-01

    The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.

  9. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  10. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  11. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  12. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  13. Field testing of a low-cost retrofit filter berm to treat stormwater runoff contaminants.

    DOT National Transportation Integrated Search

    2008-09-01

    The goal of this cooperative effort between MaineDOT and the University of New Hampshire was to test a low-cost : retrofit filter berm that would reduce non-point pollution from highway runoff. The retrofit berm would be easy to : construct using rea...

  14. SHP-1 Binds and Negatively Modulates the c-Kit Receptor by Interaction with Tyrosine 569 in the c-Kit Juxtamembrane Domain

    PubMed Central

    Kozlowski, Maya; Larose, Louise; Lee, Fai; Le, Duc Mingh; Rottapel, Robert; Siminovitch, Katherine A.

    1998-01-01

    The SH2 domain-containing SHP-1 tyrosine phosphatase has been shown to negatively regulate a broad spectrum of growth factor- and cytokine-driven mitogenic signaling pathways. Included among these is the cascade of intracellular events evoked by stem cell factor binding to c-Kit, a tyrosine kinase receptor which associates with and is dephosphorylated by SHP-1. Using a series of glutathione S-transferase (GST) fusion proteins containing either tyrosine-phosphorylated segments of the c-Kit cytosolic region or the SH2 domains of SHP-1, we have shown that SHP-1 interacts with c-Kit by binding selectively to the phosphorylated c-Kit juxtamembrane region and that the association of c-Kit with the larger of the two SHP-1 isoforms may be mediated through either the N-terminal or C-terminal SHP-1 SH2 domain. The results of binding assays with mutagenized GST-Kit juxtamembrane fusion proteins and competitive inhibition assays with phosphopeptides encompassing each c-Kit juxtamembrane region identified the tyrosine residue at position 569 as the major site for binding of SHP-1 to c-Kit and suggested that tyrosine 567 contributes to, but is not required for, this interaction. By analysis of Ba/F3 cells retrovirally transduced to express c-Kit receptors, phenylalanine substitution of c-Kit tyrosine residue 569 was shown to be associated with disruption of c-Kit–SHP-1 binding and induction of hyperproliferative responses to stem cell factor. Although phenylalanine substitution of c-Kit tyrosine residue 567 in the Ba/F3–c-Kit cells did not alter SHP-1 binding to c-Kit, the capacity of a second c-Kit-binding tyrosine phosphatase, SHP-2, to associate with c-Kit was markedly reduced, and the cells again showed hyperproliferative responses to stem cell factor. These data therefore identify SHP-1 binding to tyrosine 569 on c-Kit as an interaction pivotal to SHP-1 inhibitory effects on c-Kit signaling, but they indicate as well that cytosolic protein tyrosine phosphatases other

  15. Transit safety retrofit package development : applications requirements document.

    DOT National Transportation Integrated Search

    2014-05-01

    This Application Requirements Document for the Transit Safety Retrofit Package (TRP) Development captures the system, hardware and software requirements towards fulfilling the technical objectives stated within the contract. To achieve the objective ...

  16. Examining non-structural retrofitting status of teaching hospitals in Kerman against disasters

    PubMed Central

    Moghadam, Mahmood Nekooi; Moradi, Seyed Mobin; Amiresmaili, Mohammadreza

    2017-01-01

    Background and objective Continuous services provision of a hospital before and after a disaster is one of the most prominent issues that all people, especially the authorities must take into huge consideration. Concerning the experiences of previous earthquakes, the role and importance of nonstructural components becomes increasingly clear in the uninterrupted services of hospitals. In this study, non-structural retrofitting status of Kerman teaching hospitals was evaluated against natural disasters. Methods This cross-sectional study was carried out in the second half of 2014 on the teaching hospitals in Kerman (Iran). The study population consisted of all Kerman teaching hospitals. The research instrument was World Health Organization/Pan American Health Organization (WHO/PAHO) standard checklist. Data analysis was carried out using descriptive statistics through SPSS 19. Results One hospital had a low retrofitting level, two hospitals had an average level and one had a high level. In the examined hospitals in this study, the medical gas section had the lowest preparedness against natural disasters, while the office, warehouse and furniture section had the highest resistance. Generally, the non-structural retrofitting status was 50% in one hospital and was between 65% and 85% in other hospitals. Conclusions Generally, the retrofitting status of hospitals was not at the ideal condition, most hospitals were in average condition. Concerning the high risk of hospitals in disasters, it is necessary that senior executives and managers of Kerman Province and Kerman University of Medical Sciences take some measures to retrofit these buildings and to reduce the risk of vulnerability. PMID:28713518

  17. Note: Retrofitting an analog spectrometer for high resolving power in NUV-NIR

    NASA Astrophysics Data System (ADS)

    Taylor, Andrew S.; Batishchev, Oleg V.

    2017-11-01

    We demonstrate how an older spectrometer designed for photographic films can be efficiently retrofitted with a narrow laser-cut slit and a modern μm-pixel-size imaging CMOS camera, yielding sub-pm resolution in the broad near ultraviolet to near infrared (NUV-NIR) spectral range. Resolving power approaching 106 is achieved. Such digital retrofitting of an analog instrument is practical for research and teaching laboratories.

  18. Pim1 kinase regulates c-Kit gene translation.

    PubMed

    An, Ningfei; Cen, Bo; Cai, Houjian; Song, Jin H; Kraft, Andrew; Kang, Yubin

    2016-01-01

    Receptor tyrosine kinase, c-Kit (CD117) plays a pivotal role in the maintenance and expansion of hematopoietic stem/progenitor cells (HSPCs). Additionally, over-expression and/or mutational activation of c-Kit have been implicated in numerous malignant diseases including acute myeloid leukemia. However, the translational regulation of c-Kit expression remains largely unknown. We demonstrated that loss of Pim1 led to specific down-regulation of c-Kit expression in HSPCs of Pim1 -/- mice and Pim1 -/- 2 -/- 3 -/- triple knockout (TKO) mice, and resulted in attenuated ERK and STAT3 signaling in response to stimulation with stem cell factor. Transduction of c-Kit restored the defects in colony forming capacity seen in HSPCs from Pim1 -/- and TKO mice. Pharmacologic inhibition and genetic modification studies using human megakaryoblastic leukemia cells confirmed the regulation of c-Kit expression by Pim1 kinase: i.e., Pim1-specific shRNA knockdown down-regulated the expression of c-Kit whereas overexpression of Pim1 up-regulated the expression of c-Kit. Mechanistically, inhibition or knockout of Pim1 kinase did not affect the transcription of c-Kit gene. Pim1 kinase enhanced c-Kit 35 S methionine labeling and increased the incorporation of c-Kit mRNAs into the polysomes and monosomes, demonstrating that Pim1 kinase regulates c-Kit expression at the translational level. Our study provides the first evidence that Pim1 regulates c-Kit gene translation and has important implications in hematopoietic stem cell transplantation and cancer treatment.

  19. Expected damages of retrofitted bridges with RC jacketing

    NASA Astrophysics Data System (ADS)

    Montes, O.; Jara, J. M.; Jara, M.; Olmos, B. A.

    2015-07-01

    The bridge infrastructure in many countries of the world consists of medium span length structures built several decades ago and designed for very low seismic forces. Many of them are reinforced concrete structures that according to the current code regulations have to be rehabilitated to increase their seismic capacity. One way to reduce the vulnerability of the bridges is by using retrofitting techniques that increase the strength of the structure or by incorporating devices to reduce the seismic demand. One of the most common retrofit techniques of the bridges substructures is the use of RC jacketing; this research assesses the expected damages of seismically deficient medium length highway bridges retrofitted with reinforced concrete jacketing, by conducting a parametric study. We select a suite of twenty accelerograms of subduction earthquakes recorded close to the Pacific Coast in Mexico. The original structures consist of five 30 m span simple supported bridges with five pier heights of 5 m, 10 m, 15 m 20 and 25 m and the analyses include three different jacket thickness and three steel ratios. The bridges were subjected to the seismic records and non-linear time history analyses were carried out by using the OpenSEEs Plataform. Results allow selecting the reinforced concrete jacketing that better improves the expected seismic behavior of the bridge models.

  20. [Forensic Application of HuaxiaTM Platinum Kit].

    PubMed

    Wang, Y L; Sheng, X; Li, M; Chen, Y L; Lin, Y; Chen, L Q

    2017-04-01

    To investigate the genetic polymorphism of 23 autosomal STR loci of Huaxia™ Platinum kit in Chinese Han population, and to evaluate the forensic efficiency of Huaxia™ Platinum kit. A total of 500 unrelated healthy individuals from Han population were genotyped with Huaxia™ Platinum kit. The frequency distribution and the parameter of population genetics of STR loci were analysed statistically. Huaxia™ Platinum kit was compared with other 7 commercial STR kits commonly seen at home and abroad in the number of STR loci, interior label, fluorescent mark, total number of alleles in Ladder and system effectiveness. All the 23 autosomal STR loci were consistent with Hardy-Weinberg equilibrium ( P >0.05). The discrimination power was 0.791 5-0.986 2. The polymorphism information content (PIC) was 0.559 0-0.914 0. The combined discrimination power (CDP) was 1-4.1×10⁻²⁸, while combined probability of paternity exclusion in trio (CPET) and in duo (CPED) were 1-4.1×10⁻¹⁰ and 1-8.4×10⁻⁷, respectively. Compared with other 7 kits, Huaxia™ Platinum kit contained the most number of alleles within the Ladder. All the 23 autosomal STR loci of Huaxia™ Platinum kit with highly polymorphic in Han population can be used for paternity testing and individual identification. Compared with other 7 kits, it appears that Huaxia™ Platinum kit can provide more genetic information. Copyright© by the Editorial Department of Journal of Forensic Medicine

  1. Basic Teaching Kit on Consumer Advertising.

    ERIC Educational Resources Information Center

    Proctor and Gamble Co., Cincinnati, OH.

    This advertising kit was developed by Procter and Gamble in response to requests from teachers and consumer educators who asked for materials from business about business. The kit is not intended to cover the entire field of advertising. Rather, it centers on advertising as it is known and practiced by Procter and Gamble. The purpose of the kit is…

  2. 78 FR 41731 - Source Specific Federal Implementation Plan for Implementing Best Available Retrofit Technology...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-11

    ... Federal Implementation Plan for Implementing Best Available Retrofit Technology for Four Corners Power... Implementation Plan (FIP) to implement the Best Available Retrofit Technology (BART) requirement of the Regional... given the uncertainties in the electrical market in Arizona, EPA is proposing to extend the date by...

  3. Applicability and economic efficiency of earthquake retrofit measures on existing buildings in Bucharest, Romania

    NASA Astrophysics Data System (ADS)

    Bostenaru, M.

    2009-04-01

    The research discussed in this contribution contains two aspects: on one side the economic efficiency of seismic retrofit measures, and on the other their applicability. The research was limited to housing buildings. Bucharest, the capital of Romania, was the object of the research. Strong earthquakes affect Bucharest about three times in a century, the damaging earthquakes of the 20th century being in 1940 and 1977. Other strong earthquakes occurred in 1986 and 1990. Since it is a broad topic, first the building type was determined, which should serve further research. For this scope the building types of the 20th century, which are common in Bucharest, Romania, were investigated. For each building type reports have been written, which comprised the earthquake resilient features, the seismic defficiencies, the damage patterns and the retrofit measures. Each of these features was listed for elements of the building. A first result of the research was an integrated system in order to include latter aspects in the planning in the first steps. So already at the building survey attention has to be paid on how a building is subdivided in order to be able to determine the economic efficiency of the planned action. So were defined the `retrofit elements`. In a first step the characteristics were defined, through which these retrofit elements (for example column, wall part between two windows) can be recognised in the building survey. In a further one, which retrofit measures can be connected to these. Diagrams were built, in order to visualise these findings. For each retrofit element and the corresponding measure the costs were calculated. Also, these retrofit elements and the measures connected to them were modelled for the simulation with the structural software, so that the benefit of the measures could be determined. In the part which regarded the economic efficiency, benefits and costs of retrofit measures had to be compared, so the improvement in the rigidity

  4. Evaluation plan for state gas heating system retrofit pilot programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, L.; Vineyard, T.

    This report presents a detailed plan for the evaluation of state gas heating system retrofit pilot programs. The major goals of the evaluation procedures are to document the fuel savings and cost effectiveness of (1) the programs implemented by the states and (2) the four retrofit types installed. The major tasks involved in the evaluation include identification of program-eligible households, screening for data quality, assignment of eligible households to treatment or control groups, assembling cost data, collecting pre- and postretrofit consumption data, obtainin pre- and postretrofit weather data, checking for data quality, and analyzing the data. Data analysis relies onmore » the calculation of weather-adjusted normalized annual consumption (NAC) figures for pre- and postretrofit years for treatment and control groups. The differences between the treatment and control groups' NACs for the pre- and postretrofit years are the measure of the program's impact. Cost effectiveness analysis will combine the NAC results with cost data and with a variety of assumptions concerning future fuel prices, retrofit lifetimes, and discount rates to produce benefit/cost indicators.« less

  5. Case Study of the Maplewood Park Multifamily Retrofit for Energy Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Euy-Jin; Stephenson, Robert; Roberts, Sydney

    2012-12-01

    Maplewood Park (Maplewood), a 110-unit multifamily apartment complex in Union City, Georgia, completed major renovations under the guidance of a third-party green building certification program in October 2012. Oak Ridge National Laboratory (ORNL) partnered with Southface Energy Institute (Southface) to use this project as a case study of energy retrofits in low-rise, garden-style, multifamily buildings in the southeastern United States. This report provides a comprehensive profile of this project including the project economics, findings of the building audit, and results of the analysis of energy retrofit measures specific to this project. With a main focus of energy retrofits, this reportmore » aims to discuss other aspects of multifamily building retrofit that would benefit future projects in terms of improved building audit process, streamlined tasks, and higher energy savings in low-rise, garden-style apartments. Maplewood received Low Income Housing Tax Credit (LIHTC) financing via the 2010 Georgia Qualified Allocation Plan (QAP). To be eligible for QAP funds in Georgia, all major renovations must incorporate energy-efficiency measures and adopt a third-party green building certification. Because of the unique demands of this financing, including requirements for long-term ownership, property owners were also especially motivated to invest in upgrades that will increase durability and comfort while reducing the energy cost for the tenants.« less

  6. Cochlear implant magnet retrofit.

    PubMed

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  7. Performance of a Retrofitted Multicyclone for PM2.5 Emission Control

    NASA Astrophysics Data System (ADS)

    Dewika, M.; Rashid, M.; Ammar, M. R.

    2018-03-01

    This paper presents on the performance of a retrofitted multicyclone system, which aims to increase the collection efficiency of PM2.5 (i.e. particulate size fraction ≤ 2.5 μm) emission. The multicyclone was retrofitted by extracting 15% and 20% of the total volumetric air flow rate at the dust hopper of the unit using an additional Induced Draft Fan. The total collection efficiency with and without the extraction was measured at various air volumetric flow rates and particulate mass inlet concentration. The results showed that there was a reduction of 12% to 54% depending on the inlet concentration of PM2.5 emission in the stack with compared to without extraction increasing the collection efficiency of the retrofitted multicyclone. The finding suggests that a simple technique of applying gas extraction at the dust hopper of a multicyclone as reported in this study able to increase the overall performance in fine particulate collection.

  8. Diesel plant retrofitting options to enhance decentralized electricity supply in Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baring-Gould, E I; Barley, C D; Drouilhet, S

    1997-09-01

    Over the last 20 years, the government of Indonesia has undertaken an extensive program to provide electricity to the population of that country. The electrification of rural areas has been partially achieved through the use of isolated diesel systems, which account for about 20% of the country`s generated electricity. Due to many factors related to inefficient power production with diesels, the National Renewable Energy Laboratory, in conjunction with PLN, the Indonesian national utility, Community Power Corporation, and Idaho Power Company, analyzed options for retrofitting existing diesel power systems. This study considered the use of different combinations of advanced diesel control,more » the addition of wind generators, photovoltaics and batteries to reduce the systems of overall cost and fuel consumption. This analysis resulted in a general methodology for retrofitting diesel power systems. This paper discusses five different retrofitting options to improve the performance of diesel power systems. The systems considered in the Indonesian analysis are cited as examples for the options discussed.« less

  9. RETROFITTING CONTROL FACILITIES FOR WET-WEATHER FLOW CONTROL

    EPA Science Inventory

    Available technologies were evaluated to demonstrate the feasibility and cost effectiveness of retrofitting existing facilities to handle wet-weather flow (WWF). Cost/benefit relationships were compared to construction of new conventional control and treatment facilities. Desktop...

  10. RETROFITTING CONTROL FACILITIES FOR WET WEATHER FLOW TREATMENT

    EPA Science Inventory

    Available technologies were evaluated to demonstrate the technical feasibility and cost-effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilitie...

  11. RETROFITTING CONTROL FACILITIES FOR WET-WEATHER FLOW TREATMENT

    EPA Science Inventory

    Available technologies were evaluated to demonstrate the technical feasibility and cost effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilities...

  12. Sourcing of Steam and Electricity for Carbon Capture Retrofits.

    PubMed

    Supekar, Sarang D; Skerlos, Steven J

    2017-11-07

    This paper compares different steam and electricity sources for carbon capture and sequestration (CCS) retrofits of pulverized coal (PC) and natural gas combined cycle (NGCC) power plants. Analytical expressions for the thermal efficiency of these power plants are derived under 16 different CCS retrofit scenarios for the purpose of illustrating their environmental and economic characteristics. The scenarios emerge from combinations of steam and electricity sources, fuel used in each source, steam generation equipment and process details, and the extent of CO 2 capture. Comparing these scenarios reveals distinct trade-offs between thermal efficiency, net power output, levelized cost, profit, and net CO 2 reduction. Despite causing the highest loss in useful power output, bleeding steam and extracting electric power from the main power plant to meet the CCS plant's electricity and steam demand maximizes plant efficiency and profit while minimizing emissions and levelized cost when wholesale electricity prices are below 4.5 and 5.2 US¢/kWh for PC-CCS and NGCC-CCS plants, respectively. At prices higher than these higher profits for operating CCS retrofits can be obtained by meeting 100% of the CCS plant's electric power demand using an auxiliary natural gas turbine-based combined heat and power plant.

  13. Field Assessment of Energy Audit Tools for Retrofit Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, J.; Bohac, D.; Nelson, C.

    2013-07-01

    This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home's asset performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Home rating systems can help motivate homeowners in several ways. Ratings can clearly communicate a home's achievable energy efficiency potential, provide a quantitative assessment of energy savings after retrofits are completed, and show homeowners how they rate compared to their neighbors, thus creating an incentive to conform to amore » social standard. An important consideration is how rating tools for the retrofit market will integrate with existing home energy service programs. For residential programs that target energy savings only, home visits should be focused on key efficiency measures for that home. In order to gain wide adoption, a rating tool must be easily integrated into the field process, demonstrate consistency and reasonable accuracy to earn the trust of home energy technicians, and have a low monetary cost and time hurdle for homeowners. Along with the Home Energy Score, this project also evaluated the energy modeling performance of SIMPLE and REM/Rate.« less

  14. Existing School Buildings: Incremental Seismic Retrofit Opportunities.

    ERIC Educational Resources Information Center

    Federal Emergency Management Agency, Washington, DC.

    The intent of this document is to provide technical guidance to school district facility managers for linking specific incremental seismic retrofit opportunities to specific maintenance and capital improvement projects. The linkages are based on logical affinities, such as technical fit, location of the work within the building, cost saving…

  15. Marginal costs of water savings from cooling system retrofits: a case study for Texas power plants

    NASA Astrophysics Data System (ADS)

    Loew, Aviva; Jaramillo, Paulina; Zhai, Haibo

    2016-10-01

    The water demands of power plant cooling systems may strain water supply and make power generation vulnerable to water scarcity. Cooling systems range in their rates of water use, capital investment, and annual costs. Using Texas as a case study, we examined the cost of retrofitting existing coal and natural gas combined-cycle (NGCC) power plants with alternative cooling systems, either wet recirculating towers or air-cooled condensers for dry cooling. We applied a power plant assessment tool to model existing power plants in terms of their key plant attributes and site-specific meteorological conditions and then estimated operation characteristics of retrofitted plants and retrofit costs. We determined the anticipated annual reductions in water withdrawals and the cost-per-gallon of water saved by retrofits in both deterministic and probabilistic forms. The results demonstrate that replacing once-through cooling at coal-fired power plants with wet recirculating towers has the lowest cost per reduced water withdrawals, on average. The average marginal cost of water withdrawal savings for dry-cooling retrofits at coal-fired plants is approximately 0.68 cents per gallon, while the marginal recirculating retrofit cost is 0.008 cents per gallon. For NGCC plants, the average marginal costs of water withdrawal savings for dry-cooling and recirculating towers are 1.78 and 0.037 cents per gallon, respectively.

  16. c-KIT positive schistosomal urinary bladder carcinoma are frequent but lack KIT gene mutations.

    PubMed

    Shams, Tahany M; Metawea, Mokhtar; Salim, Elsayed I

    2013-01-01

    Urinary bladder squamous cell carcinoma (SCC), one of the most common neoplasms in Egypt, is attributed to chronic urinary infection with Schistosoma haematobium (Schistosomiasis). The proto-oncogene c-KIT, encoding a tyrosine kinase receptor and implicated in the development of a number of human malignancies, has not been studied so far in schistosomal urinary bladder SCCs. We therefore determined immunohistochemical (IHC) expression of c-KIT in paraffin sections from 120 radical cystectomies of SCCs originally obtained from the Pathology Department of Suez Canal University (Ismailia, Egypt). Each slide was evaluated for staining intensity where the staining extent of >10% of cells was considered positive. c-KIT overexpression was detected in 78.3% (94/120) of the patients, the staining extents in the tumor cells were 11-50% and >50% in 40 (42.6%) and 54 (57.4%) respectively. The positive cases had 14.9%, 63.8%, 21.3% as weak, moderate and strong intensity respectively. Patients with positive bilharzial ova had significantly higher c-KIT expression than patients without (95.2% vs. 38.9%, P=0.000). Mutation analysis of exons 9-13 was negative in thirty KIT positive cases. The high rate of positivity in SBSCC was one of the striking findings; However, CD117 may be a potential target for site specific immunotherapy to improve the outcome of this tumor.

  17. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  18. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  19. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  20. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  1. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  2. Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Schirber, B. Schoenbauer

    High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high-performance water heaters difficult to justify economically. However, recent advancements in high-performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high-efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands.

  3. Geothermal-retrofit study for the National Orange Show Facilities in San Bernardino, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-11-17

    The cost and feasibility of retrofitting the National Orange Show Facilities to use geothermal heat instead of natural gas for heating are determined. Because of the limited usage of the smaller facilities the study was limited to the conversion of the six major buildings: Domed, Hobby, Citrus, Auditorium, Restaurant and Commercial. A major problem is that most of the buildings are used on a very limited basis. This drastically reduced the amount of savings that could be used to amortize the retrofit cost. Another problem is that the buildings are spread over a large area and so the below grademore » piping costs were high. Finally, all of the buildings except for the Auditorium have direct gas fired heaters that would require all new terminal heating systems. In order to limit the retrofit cost, the retrofit system was designed to handle less than the peak load. This seemed appropriate because the facility might not even be in operation when a peak load condition occurred. Also, the existing systems could be used to supplement the geothermal system if necessary. The calculated and design peak loads are summarized.« less

  4. University of Maryland Wall Washer Retrofit - LED Modules Replace Halogen Lamps in a Performing Arts Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkerson, Andrea M.; Abell, Thomas C.; Perrin, Tess E.

    The University of Maryland (UMD) began retrofitting halogen wall washers in the Clarice Smith Performing Arts Center (CSPAC) in April 2014. The U.S. Department of Energy (DOE) Solid-State Lighting (SSL) GATEWAY program documented this process through the final installation in March 2015, summarized in this report. The wall washers illuminate hallways lining the atrium, providing task illuminance for transitioning between spaces and visual interest to the atrium boundaries. The main goals of the retrofit were to maintain the visual appearance of the space while reducing maintenance costs – energy savings was considered an additional benefit by UMD Facilities Management. UMDmore » Facilities Management is pleased with the results of this retrofit, and continues to initiate LED retrofit projects across the UMD campus.« less

  5. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  6. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  7. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  8. FES kinase participates in KIT-ligand induced chemotaxis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voisset, Edwige, E-mail: Edwige.Voisset@inserm.fr; Institut Paoli-Calmettes, Marseille; Universite de la Mediterranee, Aix-Marseille II

    2010-02-26

    FES is a cytoplasmic tyrosine kinase activated by several membrane receptors, originally identified as a viral oncogene product. We have recently identified FES as a crucial effector of oncogenic KIT mutant receptor. However, FES implication in wild-type KIT receptor function was not addressed. We report here that FES interacts with KIT and is phosphorylated following activation by its ligand SCF. Unlike in the context of oncogenic KIT mutant, FES is not involved in wild-type KIT proliferation signal, or in cell adhesion. Instead, FES is required for SCF-induced chemotaxis. In conclusion, FES kinase is a mediator of wild-type KIT signalling implicatedmore » in cell migration.« less

  9. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... will not interact dangerously in the event of leakage. (b) For transportation by aircraft, polyester...

  10. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  11. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  12. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  13. Stream Responses to a Watershed-Scale Stormwater Retrofit

    EPA Science Inventory

    Green infrastructure can reduce stormwater runoff and mitigate many of the problems associated with impervious surfaces; however, the effectiveness of retrofit stormwater management for improving aquatic health is largely untested. In the suburban, 1.8 km2 Shepherd Creek catchmen...

  14. Pilot retrofit test of refrigerant R-134a for GDSCC

    NASA Technical Reports Server (NTRS)

    Albus, J.; Brown, B.; Dungao, M.; Spencer, G.

    1994-01-01

    NASA has issued an interim policy requiring all of its Centers to eliminate consumption (purchase) of stratospheric ozone-depleting substances, including chlorofluorocarbons (CFC's), by 1995. Also, plans must be outlined for the eventual phase out of their usage. The greatest source of CFC consumption and usage at the Goldstone Deep Space Communications Complex is refrigerant R-12, which is used in many of the facility's air-conditioning systems. A pilot retrofit test shows that retrofitting R-12 air-conditioning systems with hydrofluorocarbon R-13a would be a workable means to comply with the R-12 portion of NASA's policy. Results indicate acceptable cost levels and nearly equivalent system performance.

  15. Retrofit and verification test of a 30-cm ion thruster

    NASA Technical Reports Server (NTRS)

    Dulgeroff, C. R.; Poeschel, R. L.

    1980-01-01

    Twenty modifications were found to be necessary and were approved by design review. These design modifications were incorporated in the thruster documents (drawings and procedures) to define the J series thruster. Sixteen of the design revisions were implemented in a 900 series thruster by retrofit modification. A standardized set of test procedures was formulated, and the retrofit J series thruster design was verified by test. Some difficulty was observed with the modification to the ion optics assembly, but the overall effect of the design modification satisfies the design objectives. The thruster was tested over a wide range of operating parameters to demonstrate its capabilities.

  16. Microfine coal firing results from a retrofit gas/oil-designed industrial boiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, R.; Borio, R.W.; Liljedahl, G.

    1995-12-31

    The development of a High Efficiency Advanced Coal Combustor (HEACC) has been in progress since 1987 and the ABB Power Plant Laboratories. The initial work on this concept produced an advanced coal firing system that was capable of firing both water-based and dry pulverized coal in an industrial boiler environment. Economics may one day dictate that it makes sense to replace oil or natural gas with coal in boilers that were originally designed to burn these fuels. The objective of the current program is to demonstrate the technical and economic feasibility of retrofitting a gas/oil designed boiler to burn micronizedmore » coal. In support of this overall objective, the following specific areas were targeted: A coal handling/preparation system that can meet the technical requirements for retrofitting microfine coal on a boiler designed for burning oil or natural gas; Maintaining boiler thermal performance in accordance with specifications when burning oil or natural gas; Maintaining NOx emissions at or below 0.6 lb/MBtu; Achieving combustion efficiencies of 98% or higher; and Calculating economic payback periods as a function of key variables. The overall program has consisted of five major tasks: (1) A review of current state-of-the-art coal firing system components; (2) Design and experimental testing of a prototype HEACC burner; (3) Installation and testing of a HEACC system in a commercial retrofit application; (4) Economic evaluation of the HEACC concept for retrofit applications; and (5) Long term demonstration under commercial user demand conditions. This paper will summarize the latest key experimental results (Task 3) and the economic evaluation (Task 4) of the HEACC concept for retrofit applications. 28 figs., 6 tabs.« less

  17. A Meta-Analysis of Single-Family Deep Energy Retrofit Performance in the U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Less, Brennan; Walker, Iain

    2014-08-01

    The current state of Deep Energy Retrofit (DER) performance in the U.S. has been assessed in 116 homes in the United States, using actual and simulated data gathered from the available domestic literature. Substantial airtightness reductions averaging 63% (n=48) were reported (two- to three-times more than in conventional retrofits), with average post-retrofit airtightness of 4.7 Air Changes per House at 50 Pascal (ACH50) (n=94). Yet, mechanical ventilation was not installed consistently. In order to avoid indoor air quality (IAQ) issues, all future DERs should comply with ASHRAE 62.2-2013 requirements or equivalent. Projects generally achieved good energy results, with average annualmore » net-site and net-source energy savings of 47%±20% and 45%±24% (n=57 and n=35), respectively, and carbon emission reductions of 47%±22% (n=23). Net-energy reductions did not vary reliably with house age, airtightness, or reported project costs, but pre-retrofit energy usage was correlated with total reductions (MMBtu).« less

  18. Retrofit designs for small bench-type blood cell counters.

    PubMed

    Ferris, C D

    1991-01-01

    This paper describes several retrofit designs to correct operational problems associated with small bench-type blood cell counters. Replacement electronic circuits as well as modifications to the vacuum systems are discussed.

  19. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  20. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  1. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  2. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  3. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  4. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  5. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  6. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  7. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  8. The effect of CFRP on retrofitting of damaged HSRC beams using AE technique

    NASA Astrophysics Data System (ADS)

    Soffian Noor, M. S.; Noorsuhada, M. N.

    2017-12-01

    This paper presents the effect of carbon fibre reinforced polymer (CFRP) on retrofitted high strength reinforced concrete (HSRC) beams using acoustic emission (AE) technique. Two RC beam parameters were prepared. The first was the control beam which was undamaged HSRC beam. The second was the damaged HSRC beam retrofitted with CFRP on the soffit. The main objective of this study is to assess the crack modes of HSRC beams using AE signal strength. The relationship between signal strength, load and time were analysed and discussed. The crack pattern observed from the visual observation was also investigated. HSRC beam retrofitted with CFRP produced high signal strength compared to control beam. It demonstrates the effect of the AE signal strength for interpretation and prediction of failure modes that might occur in the beam specimens.

  9. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fallahi, A.; Duraschlag, H.; Elliott, D.

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulk insulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses amore » radiant barrier composed of two aluminum foils combined with an enclosed reflective air space and the second uses spray-applied interior radiation control coatings (IRCC).« less

  10. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fallahi, A.; Durschlag, H.; Elliott, D.

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiantmore » barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).« less

  11. The challenges of lean manufacturing implementation in kitting assembly

    NASA Astrophysics Data System (ADS)

    Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.

    2017-10-01

    Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.

  12. A Meta-Analysis of Single-Family Deep Energy Retrofit Performance in the U.S.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Less, Brennan; Walker, Iain

    2014-03-01

    The current state of Deep Energy Retrofit (DER) performance in the U.S. has been assessed in 116 homes in the United States (US), using actual and simulated data gathered from the available domestic literature. Substantial airtightness reductions averaging 63% (n=48) were reported (two- to three-times more than in conventional retrofits), with average post-retrofit airtightness of 4.7 Air Changes per House at 50 Pascal (ACH50) (n=94). Yet, mechanical ventilation was not installed consistently. In order to avoid indoor air quality (IAQ) issues, all future DERs should comply with ASHRAE 62.2-2013 requirements or equivalent. Projects generally achieved good energy results, with averagemore » annual net-site and net-source energy savings of 47%±20% and 45%±24% (n=57 and n=35), respectively, and carbon emission reductions of 47%±22% (n=23). Net-energy reductions did not vary reliably with house age, airtightness, or reported project costs, but pre-retrofit energy usage was correlated with total reductions (MMBtu). Annual energy costs were reduced $1,283±$804 (n=31), from a pre-retrofit average of $2,738±$1,065 to $1,588±$561 post-retrofit (n=25 and n=39). The average reported incremental project cost was $40,420±$30,358 (n=59). When financed on a 30-year term, the median change in net-homeownership cost was only $1.00 per month, ranging from $149 in savings to an increase of $212 (mean=$15.67±$87.74; n=28), and almost half of the projects resulted in reductions in net-cost. The economic value of a DER may be much greater than is suggested by these net-costs, because DERs entail substantial non-energy benefits (NEBs), and retrofit measures may add value to a home at resale similarly to general remodeling, PV panel installation, and green/energy efficient home labels. These results provide estimates of the potential of DERs to address energy use in existing homes across climate zones that can be used in future estimates of the technical potential to reduce

  13. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  14. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  15. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  16. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  17. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  18. Scalable methodology for large scale building energy improvement: Relevance of calibration in model-based retrofit analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heo, Yeonsook; Augenbroe, Godfried; Graziano, Diane

    2015-05-01

    The increasing interest in retrofitting of existing buildings is motivated by the need to make a major contribution to enhancing building energy efficiency and reducing energy consumption and CO2 emission by the built environment. This paper examines the relevance of calibration in model-based analysis to support decision-making for energy and carbon efficiency retrofits of individual buildings and portfolios of buildings. The authors formulate a set of real retrofit decision-making situations and evaluate the role of calibration by using a case study that compares predictions and decisions from an uncalibrated model with those of a calibrated model. The case study illustratesmore » both the mechanics and outcomes of a practical alternative to the expert- and time-intense application of dynamic energy simulation models for large-scale retrofit decision-making under uncertainty.« less

  19. Measure Guideline. Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loomis, H.; Pettit, B.

    2015-05-29

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls.

  20. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loomis, H.; Pettit, B.

    2015-05-01

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.

  1. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  2. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  3. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  4. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  5. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  6. Planning Systems. SPEC Kit 13.

    ERIC Educational Resources Information Center

    Association of Research Libraries, Washington, DC. Office of Management Studies.

    This kit on planning systems updates a 1974 Management Studies Office Systems and Procedures Exchange Center (SPEC) kit in which developments in planning activities among Association of Research Libraries (ARL) were reviewed. At the time of the original study, in 1972, planning techniques and systems were a subject of much interest because rising…

  7. Multicriteria decision model for retrofitting existing buildings

    NASA Astrophysics Data System (ADS)

    Bostenaru Dan, B.

    2003-04-01

    In this paper a model to decide which buildings from an urban area should be retrofitted is presented. The model has been cast into existing ones by choosing the decision rule, criterion weighting and decision support system types most suitable for the spatial problem of reducing earthquake risk in urban areas, considering existing spatial multiatributive and multiobjective decision methods and especially collaborative issues. Due to the participative character of the group decision problem "retrofitting existing buildings" the decision making model is based on interactivity. Buildings have been modeled following the criteria of spatial decision support systems. This includes identifying the corresponding spatial elements of buildings according to the information needs of actors from different sphaeres like architects, construction engineers and economists. The decision model aims to facilitate collaboration between this actors. The way of setting priorities interactivelly will be shown, by detailing the two phases: judgemental and computational, in this case site analysis, collection and evaluation of the unmodified data and converting survey data to information with computational methods using additional expert support. Buildings have been divided into spatial elements which are characteristic for the survey, present typical damages in case of an earthquake and are decisive for a better seismic behaviour in case of retrofitting. The paper describes the architectural and engineering characteristics as well as the structural damage for constuctions of different building ages on the example of building types in Bucharest, Romania in compressible and interdependent charts, based on field observation, reports from the 1977 earthquake and detailed studies made by the author together with a local engineer for the EERI Web Housing Encyclopedia. On this base criteria for setting priorities flow into the expert information contained in the system.

  8. Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frozyna, K.; Badger, L.

    2013-04-01

    This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls,more » and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.« less

  9. Glider kits cut truck ownership costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smiley, C.H.

    1983-06-01

    A glider kit consists of a new truck without the power train, with the customer supplying the engine, transmission, clutch, driveline and rear axles for mounting in a new frame and cab complete with steering axle, wiring harnesses, exhaust system and cooling system. Glider kits have long been regarded as a cost effective means of replacing accident or fire damaged late model vehicles. The financial advantages, assembly and remanufacturing are discussed. Points out that at a basic cost about one third of a new truck, a glider kit offers lower cost of borrowed capital, tax savings, and elimination of highmore » maintenance and downtime costs. The paper concludes that use of glider kits as an alternative to major repair or reconditioning or outright replacement of coal haulers presents some interesting options.« less

  10. Look Around You, Kit I.

    ERIC Educational Resources Information Center

    1971

    Developing pupils' awareness of their environment, learning to distinguish between what is pleasant and unpleasant, and examining acts of man to determine which are destructive and which are in harmony with nature are the purposes of Scholastic's Earth Corps Environmental Study Kits for grades 1-6. This kit is designed to help the child develop…

  11. First Follow Nature, Kit II.

    ERIC Educational Resources Information Center

    1971

    Developing pupils' awareness of their environment, learning to distinguish between what is pleasant and unpleasant, and examining acts of man to determine which are destructive and which are in harmony with nature are the purposes of Scholastic's Earth Corps Environmental Study Kits for Grades 1-6. This kit explores in depth the reasons some…

  12. Comparative feasibility study on retrofitting ballast water treatment system for a bulk carrier.

    PubMed

    Jee, Jaehoon; Lee, Sangick

    2017-06-30

    Use of ballast water in ships causes harmful effects on marine environment accompanied by economic loss and negative impact on ecosystem and human health. To solve these problems, the international convention on ballast water management will take into force in September 2017. In this study, a comprehensive feasibility of retrofitting the ballast water treatment system for an ocean-going bulk carrier was conducted. The technologies involved, installation and operational aspects of direct flow and side stream electrolysis, UV, and ozone type BWTS are described in detail. The principal concept of each BWTS is explained and probable arrangements of retrofitting in engine room are suggested. The cost analysis is carried out for retrofitting 4 types of BWTS onboard the target ship by examining each processes of installation and operation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    PubMed

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  14. Travel Medical Kit.

    PubMed

    Terry, Anne C; Haulman, N Jean

    2016-03-01

    "The traveler's medical kit is an essential tool for both the novice and expert traveler. It is designed to treat travel-related illness and injury and to ensure preexisting medical conditions are managed appropriately. Travelers are at increased risk for common gastrointestinal issues during travel. Respiratory illnesses make up approximately 8% of the ailments present in returned international travelers. Approximately 12% of travelers experience a travel-related skin condition. First aid treatment for minor injuries is essential to all travel medical kits. The complexity ranges from a small, simple case for the urban traveler to a larger, extensive case for wilderness travel." Copyright © 2016 Elsevier Inc. All rights reserved.

  15. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  16. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  17. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  18. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  19. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  20. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  1. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  2. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  3. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  4. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  5. Experiment study on RC frame retrofitted by the external structure

    NASA Astrophysics Data System (ADS)

    Liu, Chunyang; Shi, Junji; Hiroshi, Kuramoto; Taguchi, Takashi; Kamiya, Takashi

    2016-09-01

    A new retrofitting method is proposed herein for reinforced concrete (RC) structures through attachment of an external structure. The external structure consists of a fiber concrete encased steel frame, connection slab and transverse beams. The external structure is connected to the existing structure through a connection slab and transverse beams. Pseudostatic experiments were carried out on one unretrofitted specimen and three retrofitted frame specimens. The characteristics, including failure mode, crack pattern, hysteresis loops behavior, relationship of strain and displacement of the concrete slab, are demonstrated. The results show that the load carrying capacity is obviously increased, and the extension length of the slab and the number of columns within the external frame are important influence factors on the working performance of the existing structure. In addition, the displacement difference between the existing structure and the outer structure was caused mainly by three factors: shear deformation of the slab, extraction of transverse beams, and drift of the conjunction part between the slab and the existing frame. Furthermore, the total deformation determined by the first two factors accounted for approximately 80% of the damage, therefore these factors should be carefully considered in engineering practice to enhance the effects of this new retrofitting method.

  6. Molecular Retrofitting Adapts a Metal–Organic Framework to Extreme Pressure

    DOE PAGES

    Kapustin, Eugene A.; Lee, Seungkyu; Alshammari, Ahmad S.; ...

    2017-06-07

    Despite numerous studies on chemical and thermal stability of metal-organic frameworks (MOFs), mechanical stability remains largely undeveloped. No strategy exists to control the mechanical deformation of MOFs under ultrahigh pressure, to date. We show that the mechanically unstable MOF-520 can be retrofitted by precise placement of a rigid 4,4'-biphenyldicarboxylate (BPDC) linker as a "girder" to afford a mechanically robust framework: MOF-520-BPDC. This retrofitting alters how the structure deforms under ultrahigh pressure and thus leads to a drastic enhancement of its mechanical robustness. While in the parent MOF-520 the pressure transmitting medium molecules diffuse into the pore and expand the structuremore » from the inside upon compression, the girder in the new retrofitted MOF-520-BPDC prevents the framework from expansion by linking two adjacent secondary building units together. As a result, the modified MOF is stable under hydrostatic compression in a diamond-anvil cell up to 5.5 gigapascal. The increased mechanical stability of MOF-520-BPDC prohibits the typical amorphization observed for MOFs in this pressure range. Direct correlation between the orientation of these girders within the framework and its linear strain was estimated, providing new insights for the design of MOFs with optimized mechanical properties.« less

  7. Improving Management of Green Retrofits from a Stakeholder Perspective: A Case Study in China.

    PubMed

    Liang, Xin; Shen, Geoffrey Qiping; Guo, Li

    2015-10-28

    Green retrofits, which improve the environment and energy efficiency of buildings, are considered a potential solution for reducing energy consumption as well as improving human health and productivity. They represent some of the riskiest, most complex, and most uncertain projects to manage. As the foundation of project management, critical success factors (CSFs) have been emphasized by previous research. However, most studies identified and prioritized CSFs independently of stakeholders. This differs from the reality, where the success of green retrofits is tightly interrelated to the stakeholders of projects. To improve the analysis from a stakeholder perspective, the present study proposed an innovative method based on a two-mode social network analysis to integrate CSF analysis with stakeholders. The results of this method can provide further understanding of the interactions between stakeholders and CSFs, and the underlying relationship among CSFs through stakeholders. A pilot study was conducted to apply the proposed method and assess the CSFs for green retrofits in China. The five most significant CSFs are identified in the management of green retrofit. Furthermore, the interrelations between stakeholders and CSFs, coefficient and clusters of CSFs are likewise discussed.

  8. Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, R.; Leach, M.; Bonnema, E.

    The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations aremore » applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.« less

  9. Improving Management of Green Retrofits from a Stakeholder Perspective: A Case Study in China

    PubMed Central

    Liang, Xin; Shen, Geoffrey Qiping; Guo, Li

    2015-01-01

    Green retrofits, which improve the environment and energy efficiency of buildings, are considered a potential solution for reducing energy consumption as well as improving human health and productivity. They represent some of the riskiest, most complex, and most uncertain projects to manage. As the foundation of project management, critical success factors (CSFs) have been emphasized by previous research. However, most studies identified and prioritized CSFs independently of stakeholders. This differs from the reality, where the success of green retrofits is tightly interrelated to the stakeholders of projects. To improve the analysis from a stakeholder perspective, the present study proposed an innovative method based on a two-mode social network analysis to integrate CSF analysis with stakeholders. The results of this method can provide further understanding of the interactions between stakeholders and CSFs, and the underlying relationship among CSFs through stakeholders. A pilot study was conducted to apply the proposed method and assess the CSFs for green retrofits in China. The five most significant CSFs are identified in the management of green retrofit. Furthermore, the interrelations between stakeholders and CSFs, coefficient and clusters of CSFs are likewise discussed. PMID:26516897

  10. Psychometric Properties of the Concept Assessment Kit-Conservation.

    ERIC Educational Resources Information Center

    Lehnert, Linda; And Others

    1986-01-01

    This study investigated the psychometric properties of the Educational and Industrial Testing Service Concept Assessment Kit-Conservation (EITS Kit). Presented are an overview of the concept of conservation, a description of the EITS Kit, and results of the study. (MT)

  11. Highway Vehicle Retrofit Evaluation : Phase I. Analysis and Preliminary Evaluation Results. Volume 1. Sections 1 through 3.

    DOT National Transportation Integrated Search

    1975-11-01

    This report in two volumes presents an analysis and preliminary evaluation of selected used-car and light-truck fuel economy retrofit devices. In particular, information is provided that depicts the performance characteristics of retrofit devices tha...

  12. Evaluating the performance of a retrofitted stormwater wet pond for treatment of urban runoff.

    PubMed

    Schwartz, Daniel; Sample, David J; Grizzard, Thomas J

    2017-06-01

    This paper describes the performance of a retrofitted stormwater retention pond (Ashby Pond) in Northern Virginia, USA. Retrofitting is a common practice which involves modifying existing structures and/or urban landscapes to improve water quality treatment, often compromising standards to meet budgetary and site constraints. Ashby Pond is located in a highly developed headwater watershed of the Potomac River and the Chesapeake Bay. A total maximum daily load (TMDL) was imposed on the Bay watershed by the US Environmental Protection Agency in 2010 due to excessive sediment and nutrient loadings leading to eutrophication of the estuary. As a result of the TMDL, reducing nutrient and sediment discharged loads has become the key objective of many stormwater programs in the Bay watershed. The Ashby Pond retrofit project included dredging of accumulated sediment to increase storage, construction of an outlet structure to control flows, and repairs to the dam. Due to space limitations, pond volume was less than ideal. Despite this shortcoming, Ashby Pond provided statistically significant reductions of phosphorus, nitrogen, and suspended sediments. Compared to the treatment credited to retention ponds built to current state standards, the retrofitted pond provided less phosphorus but more nitrogen reduction. Retrofitting the existing stock of ponds in a watershed to at least partially meet current design standards could be a straightforward way for communities to attain downstream water quality goals, as these improvements represent reductions in baseline loads, whereas new ponds in new urban developments simply limit future load increases or maintain the status quo.

  13. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  14. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  15. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  16. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  17. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  18. DEEP: A Database of Energy Efficiency Performance to Accelerate Energy Retrofitting of Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoon Lee, Sang; Hong, Tianzhen; Sawaya, Geof

    The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions andmore » 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to

  19. Liquid balance monitoring inside conventional, Retrofit, and bio-reactor landfill cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abichou, Tarek, E-mail: abichou@eng.fsu.edu; Barlaz, Morton A.; Green, Roger

    Highlights: • The Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup −1} (liters of liquids per metric ton of waste). • The leachate collection system yielded 60, 57 and 198 L Mg{sup −1} from the Retrofit, Control, and As-Built cells. • The head on liner in all cells was below regulatory limits. • Measured moisture content of the waste samples was consistent with that calculated from accumulated liquid by balance. • The in-place saturated hydraulic conductivity of the MSW was calculated to be in the range of 10{sup −8} to 10{sup −7} m s{sup −1}. -more » Abstract: The Outer Loop landfill bioreactor (OLLB) in Louisville, KY, USA has been the site of a study to evaluate long-term bioreactor performance at a full-scale operational landfill. Three types of landfill units were studied including a conventional landfill (Control cell), a new landfill area that had an air addition and recirculation piping network installed as waste was being placed (As-Built cell), and a conventional landfill that was modified to allow for liquids recirculation (Retrofit cell). During the monitoring period, the Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup −1} (liters of liquids per metric ton of waste), respectively. The leachate collection system yielded 60, 57 and 198 L Mg{sup −1} from the Retrofit, Control, and As-Built cells, respectively. The head on liner in all cells was below regulatory limits. In the Control and As-Built cells, leachate head on liner decreased once waste placement stopped. The measured moisture content of the waste samples was consistent with that calculated from the estimate of accumulated liquid by the liquid balance. Additionally, measurements on excavated solid waste samples revealed large spatial variability in waste moisture content. The degree of saturation in the Control cells decreased from 85% to 75%. The degree of saturation increased from 82% to 83% due to liquids addition in the

  20. 40 CFR 52.2501 - Best available retrofit technology (BART) requirement for the Tesoro Refining and Marketing...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 5 2014-07-01 2014-07-01 false Best available retrofit technology... Best available retrofit technology (BART) requirement for the Tesoro Refining and Marketing Company oil... 10, to the following email address: [email protected] Effective Date Note: At 79 FR 33454...

  1. Unstable Resonator Retrofitted Handheld Laser Designator

    DTIC Science & Technology

    1978-06-01

    retrofitted with a negative-branch unstable resona- tor laser and hybrid pump cavity in place of the conventional plane-mirror/ porro prism resonator and...directed by prism B to an expanding telescope, shared with the viewing system of the designator. The actual, unfolded resonator length is approxi...was performed based on using a plane- parallel cavity consisting of a 47% reflectivity output coupler, porro - prism reflector, and the same LiNb03

  2. Validation and Design of Sheet Retrofits

    DTIC Science & Technology

    2010-10-31

    enough to allow for rotation of the top of the wall without development of an axial force. Obviously, these walls are not load bearing . This type...structures are commonly constructed using CMU blocks to infill non- load bearing walls (Hammons, 1999). Many of these structures were built in a... axial loads within the sheet. 3 Figure 1. Infill Masonry Wall Retrofit Concept 2.1. Objective The objective of the research documented in

  3. Housing Archetype Analysis for Home Energy-Efficient Retrofit in the Great Lakes Region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, S. -K.; Mrozowski, T.; Harrell-Seyburn, A.

    This project report details activities and results of the "Market Characterization" project undertaken by the Cost Effective Energy Retrofit (CEER) team targeted toward the DOE goal of achieving 30%-50% reduction in existing building energy use. CEER consists of members from the Dow Chemical Company, Michigan State University, Ferris State University, and Habitat for Humanity Kent County. The purpose of this market characterization project was to identify housing archetypes which are dominant within the Great Lakes region and therefore offer significant potential for energy-efficient retrofit research and implementation due to the substantial number of homes possessing similar characteristics. Understanding the characteristicsmore » of housing groups referred to as "archetypes" by vintage, style, and construction characteristics can allow research teams to focus their retrofit research and develop prescriptive solutions for those structure types which are prevalent and offer high potential uptake within a region or market.« less

  4. Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiehagen, J.; Del Bianco, M.; Mallay, D.

    2015-05-01

    In the fall of 2010, a multiyear pilot energy efficiency retrofit project was undertaken by Greenbelt Homes, Inc, (GHI) a 1,566 home cooperative of circa 1930 and 1940 homes in Greenbelt, Maryland. GHI established this pilot project to serve as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy efficiency improvements to the building envelope and mechanical equipment. It presents a unique opportunity to evaluate and prioritize the wide-range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressingmore » the complex interactions between benefits, trade-offs, construction methods, project management implications, realistic upfront costs, financing, and other considerations, serves as a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner. The pilot project focused on identifying the added costs and energy savings benefits of improvements.« less

  5. A Wireless Platform for Energy Efficient Building Control Retrofits

    DTIC Science & Technology

    2012-07-01

    operate /tune the proposed controller and maintain WSN after reasonable training Feedback from CERL facility staff/ managemen t on ease of operation and...26 4.2 FACILITY/SITE LOCATION AND OPERATIONS ...HVAC RETROFITS ...................................................................................................... 36 5.4 OPERATIONAL TESTING

  6. Transit safety retrofit package development : TRP concept of operations.

    DOT National Transportation Integrated Search

    2014-05-01

    This document describes the Concept of Operations (ConOps) for the Transit Safety Retrofit Package (TRP). The ConOps describes the current state of operations with respect to the integration of Connected Vehicle technology in transit buses, establish...

  7. Culture Kits for the Elementary Classroom.

    ERIC Educational Resources Information Center

    Hickey, M. Gail

    1997-01-01

    Outlines an instructional unit where students construct culture kits illustrating a specific culture. Culture kits are constructed out of realia and other material including maps, travel brochures, photographs, newspapers, souvenirs, and other items. Discusses collecting these items and possible multicultural applications. (MJP)

  8. Genetic lineage tracing identifies in situ Kit-expressing cardiomyocytes

    PubMed Central

    Liu, Qiaozhen; Yang, Rui; Huang, Xiuzhen; Zhang, Hui; He, Lingjuan; Zhang, Libo; Tian, Xueying; Nie, Yu; Hu, Shengshou; Yan, Yan; Zhang, Li; Qiao, Zengyong; Wang, Qing-Dong; Lui, Kathy O; Zhou, Bin

    2016-01-01

    Cardiac cells marked by c-Kit or Kit, dubbed cardiac stem cells (CSCs), are in clinical trials to investigate their ability to stimulate cardiac regeneration and repair. These studies were initially motivated by the purported cardiogenic activity of these cells. Recent lineage tracing studies using Kit promoter to drive expression of the inducible Cre recombinase showed that these CSCs had highly limited cardiogenic activity, inadequate to support efficient cardiac repair. Here we reassess the lineage tracing data by investigating the identity of cells immediately after Cre labeling. Our instant lineage tracing approach identifies Kit-expressing cardiomyocytes, which are labeled immediately after tamoxifen induction. In combination with long-term lineage tracing experiments, these data reveal that the large majority of long-term labeled cardiomyocytes are pre-existing Kit-expressing cardiomyocytes rather than cardiomyocytes formed de novo from CSCs. This study presents a new interpretation for the contribution of Kit+ cells to cardiomyocytes and shows that Kit genetic lineage tracing over-estimates the cardiogenic activity of Kit+ CSCs. PMID:26634606

  9. Underwater Adhesives Retrofit Pipelines with Advanced Sensors

    NASA Technical Reports Server (NTRS)

    2015-01-01

    Houston-based Astro Technology Inc. used a partnership with Johnson Space Center to pioneer an advanced fiber-optic monitoring system for offshore oil pipelines. The company's underwater adhesives allow it to retrofit older deepwater systems in order to measure pressure, temperature, strain, and flow properties, giving energy companies crucial data in real time and significantly decreasing the risk of a catastrophe.

  10. Discovery of amido-benzisoxazoles as potent c-Kit inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunz, Roxanne K.; Rumfelt, Shannon; Chen, Ning

    2010-01-12

    Deregulation of the receptor tyrosine kinase c-Kit is associated with an increasing number of human diseases, including certain cancers and mast cell diseases. Interference of c-Kit signaling with multi-kinase inhibitors has been shown clinically to successfully treat gastrointestinal stromal tumors and mastocytosis. Targeted therapy of c-Kit activity may provide therapeutic advantages against off-target effects for non-oncology applications. A new structural class of c-Kit inhibitors is described, including in vitro c-Kit potency, kinase selectivity, and the observed binding mode.

  11. Personal Computer-less (PC-less) Microcontroller Training Kit

    NASA Astrophysics Data System (ADS)

    Somantri, Y.; Wahyudin, D.; Fushilat, I.

    2018-02-01

    The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.

  12. An analysis and retrofit of the acoustics at Image Creators Health and Beauty Salon

    NASA Astrophysics Data System (ADS)

    Ellis, Donna

    2002-11-01

    This paper discusses the analysis and retrofit of the acoustics in a high-volume beauty salon in Severna Park, MD. The major issues in what was designed to be a serene environment are reverberation times of 1-1.68 s in the mid- to upper-frequency range. Employee and customer complaints include heightened stress, vocal strain, headaches, and poor intelligibility. Existing analysis and acoustical retrofit solutions will be demonstrated.

  13. Public Housing: A Tailored Approach to Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Dentz; Conlin, F.; Podorson, D.

    2016-02-23

    The Building America research team Advanced Residential Integrated Energy Solutions Collaborative (ARIES) worked with four public housing authorities (PHAs) to develop packages of energy-efficiency retrofit measures that the PHAs can cost-effectively implement with their own staffs during the normal course of housing operations when units are refurbished between occupancies.

  14. YourSELF. Middle School Nutrition Education Kit [Multimedia].

    ERIC Educational Resources Information Center

    Department of Agriculture, Washington, DC.

    This multimedia kit provides information and materials for teaching nutrition to middle school students (grades 7 and 8). The kit supports schools' efforts to make school meals healthier and more appealing to students. The materials provide information about the relationships between food, nutrition, growth, and health. The kit speaks directly to…

  15. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  16. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  17. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  18. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  19. Deep Energy Retrofits - Eleven California Case Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Less, Brennan; Fisher, Jeremy; Walker, Iain

    2012-10-01

    This research documents and demonstrates viable approaches using existing materials, tools and technologies in owner-conducted deep energy retrofits (DERs). These retrofits are meant to reduce energy use by 70% or more, and include extensive upgrades to the building enclosure, heating, cooling and hot water equipment, and often incorporate appliance and lighting upgrades as well as the addition of renewable energy. In this report, 11 Northern California (IECC climate zone 3) DER case studies are described and analyzed in detail, including building diagnostic tests and end-use energy monitoring results. All projects recognized the need to improve the home and its systemsmore » approximately to current building code-levels, and then pursued deeper energy reductions through either enhanced technology/ building enclosure measures, or through occupant conservation efforts, both of which achieved impressive energy performance and reductions. The beyond-code incremental DER costs averaged $25,910 for the six homes where cost data were available. DERs were affordable when these incremental costs were financed as part of a remodel, averaging a $30 per month increase in the net-cost of home ownership.« less

  20. Efficiency of blue-green stormwater retrofits for flood mitigation - Conclusions drawn from a case study in Malmö, Sweden.

    PubMed

    Haghighatafshar, Salar; Nordlöf, Beatrice; Roldin, Maria; Gustafsson, Lars-Göran; la Cour Jansen, Jes; Jönsson, Karin

    2018-02-01

    Coupled one-dimensional (1D) sewer and two-dimensional (2D) overland flow hydrodynamic models were constructed to evaluate the flood mitigation efficiency of a renowned blue-green stormwater retrofit, i.e. Augustenborg, in Malmö, Sweden. Simulation results showed that the blue-green stormwater systems were effective in controlling local surface flooding in inner-city catchments, having reduced the total flooded surfaces by about 70%. However, basement flooding could still be a potential problem depending on the magnitude of the inflows through combined sewer from upstream areas. Moreover, interactions between blue-green retrofits and the surrounding pipe-system were studied. It was observed that the blue-green retrofits reduced the peak flows by approximately 80% and levelled out the runoff. This is a substantial advantage for downstream pipe-bound catchments, as they do not receive a cloudburst-equivalent runoff from the retrofitted catchment, but a reduced flow corresponding to a much milder rainfall. Blue-green retrofits are more effective if primarily implemented in the upstream areas of a pipe-bound catchment since the resulting reduced runoff and levelled out discharge would benefit the entire network lying downstream. Implementing blue-green retrofits from upstream towards downstream can be considered as a sustainable approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... requirements of subpart B of this part and may not exceed 30 kg (66 pounds) gross weight; (5) Except for Carbon... kits must include sufficient absorbent material to completely absorb the contents of any liquid...

  2. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requirements of subpart B of this part and may not exceed 30 kg (66 pounds) gross weight; (5) Except for Carbon... kits must include sufficient absorbent material to completely absorb the contents of any liquid...

  3. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... requirements of subpart B of this part and may not exceed 30 kg (66 pounds) gross weight; (5) Except for Carbon... kits must include sufficient absorbent material to completely absorb the contents of any liquid...

  4. Comparison among different retrofitting strategies for the vulnerability reduction of masonry bell towers

    NASA Astrophysics Data System (ADS)

    Milani, Gabriele; Shehu, Rafael; Valente, Marco

    2017-11-01

    This paper investigates the effectiveness of reducing the seismic vulnerability of masonry towers by means of innovative and traditional strengthening techniques. The followed strategy for providing the optimal retrofitting for masonry towers subjected to seismic risk relies on preventing active failure mechanisms. These vulnerable mechanisms are pre-assigned failure patterns based on the crack patterns experienced during the past seismic events. An upper bound limit analysis strategy is found suitable to be applied for simplified tower models in their present state and the proposed retrofitted ones. Taking into consideration the variability of geometrical features and the uncertainty of the strengthening techniques, Monte Carlo simulations are implemented into the limit analysis. In this framework a wide range of idealized cases are covered by the conducted analyses. The retrofitting strategies aim to increase the shear strength and the overturning load carrying capacity in order to reduce vulnerability. This methodology gives the possibility to use different materials which can fulfill the structural implementability requirements.

  5. Effects of retrofitting emission control systems on in-use heavy diesel vehicles.

    PubMed

    Millstein, Dev E; Harley, Robert A

    2010-07-01

    Diesel engines are now the largest source of nitrogen oxides (NO(x)) and fine particulate black carbon (soot) emissions in California. The California Air Resources Board recently adopted a rule requiring that by 2014 all in-use heavy trucks and buses meet current (2007) exhaust particulate matter (PM) emission standards. Also by 2023 all in-use heavy-duty vehicles will have to meet current NO(x) emission standards, with significant progress in achieving the requirements for NO(x) control expected by 2014. This will require retrofit or replacement of older in-use engines. Diesel particle filters (DPF) reduce PM emissions but may increase the NO(2)/NO(x) emission ratio to approximately 35%, compared to approximately 5% typical of diesel engines without particle filters. Additionally, DPF with high oxidative capacity reduce CO and hydrocarbon emissions. We evaluate the effects of retrofitting trucks with DPF on air quality in southern California, using an Eulerian photochemical air quality model. Compared to a 2014 reference scenario without the retrofit program, black carbon concentrations decreased by 12 +/- 2% and 14 +/- 2% during summer and fall, respectively, with corresponding increases in ambient ozone concentrations of 3 +/- 2% and 7 +/- 3%. NO(2) concentrations decreased by 2-4% overall despite the increase in primary NO(2) emissions because total NO(x) emissions were reduced as part of the program to retrofit NO(x) control systems on in-use engines. However, in some cases NO(2) concentrations may increase at locations with high diesel truck traffic.

  6. Relationships between indoor radon concentrations, thermal retrofit and dwelling characteristics.

    PubMed

    Collignan, Bernard; Le Ponner, Eline; Mandin, Corinne

    2016-12-01

    A monitoring campaign was conducted on a sample of more than 3400 dwellings in Brittany, France from 2011 to 2014. The measurements were collected using one passive dosimeter per dwelling over two months during the heating season, according to the NF ISO 11665-8 (2013) standard. Moreover, building characteristics such as the period of construction, construction material, type of foundation, and thermal retrofit were determined using a questionnaire. The final data set consisted of 3233 houses with the measurement results and the questionnaire answers. Multivariate linear regression models were applied to explore the relationships between the indoor radon concentrations and building characteristics, particularly the thermal retrofit. The geometric mean of the indoor radon concentration was 155 Bq m -3 (with a geometric standard deviation of 3). The houses that had undergone a thermal retrofit had a higher average radon concentration than those that had not, which may have been due to a decrease in air permeability of the building envelope following rehabilitation work that did not systematically include proper management of the ventilation. Other building characteristics, primarily the building material and the foundation type, were associated with the indoor radon concentration. The indoor radon concentrations were higher in older houses built with granite or other stone, with a slab-on-grade foundation and without any ventilation system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Dowel Bar Retrofit Mix Design and Specification : Technical Report

    DOT National Transportation Integrated Search

    2012-01-01

    Current INDOT specifications for repair materials to be used in dowel bar retrofit (DBR) applications (Sections 507.08 and 901.07 of INDOTs Book of Specifications) are based, in large part, on the requirements of ASTM C 928 and the manufacturer-pr...

  8. Energy Efficient Window Retrofits in Historic Facilities

    DTIC Science & Technology

    2006-01-01

    possible, protect and maintain existing building fabric (Ivy, 1992). Barista (2001) states that during a time when interest in the restoration of...are the eyes of a building ( Barista , 2001). Certainly windows are an element, which if replaced or altered unsympathetically, will do the most to alter...problem area is to assure that retrofitting measures do not create moisture related deterioration problems ( Barista , 2001). Finally contractors and

  9. Dissolution of cement, root caries, fracture, and retrofit of post and cores.

    PubMed

    Rosen, H

    1998-10-01

    Fixed partial denture abutments severely damaged by dental caries or fracture present a challenge to the dentist. The fixed partial denture may need to be removed for endodontic treatment with post and core fabrication. Frequently, the existing fixed partial denture can be recycled as a provisional restoration. Retrofitting the post and core greatly improves the stabilization of the interim as well as the remake of the definitive fixed partial denture. This article describes a chair side procedure for retrofitting posts and cores and, at the same appointment, converting the original fixed partial denture to an effective provisional restoration.

  10. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  11. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  12. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  13. The Fluid Dynamics Demo Kit: Part I

    NASA Astrophysics Data System (ADS)

    Flack, Karen; Underhill, Patrick; Prestridge, Kathy

    2012-11-01

    The goal of this project is to develop a fluid dynamics demonstration/experiment kit that can be used by professors and graduate students at high school outreach events. The demonstrations in the kit will be easy to use and true crowd pleasers in order to inspire understanding and pique curiosity about the physics of flow. The kits will be inexpensive, containing readily available materials so that teachers can duplicate the demonstrations and experiments. The kits will be left with the teachers as a gift from the American Physics Society. The experiments and demonstrations cover the concepts of conservation of mass, momentum, and energy, Bernoulli's equation, frictional losses and the ideal gas law. For each experiment, the teachers will receive presentation material, access to instructional videos, plus a worksheet that can be used in a high school physics classroom. This kit has been developed through the efforts of the APS-DFD Mentoring and Outreach Committee and has received funding from the APS-DFD. Work funded by the APS-DFD.

  14. Orbital Maneuvering Vehicle (OMV) remote servicing kit

    NASA Technical Reports Server (NTRS)

    Brown, Norman S.

    1988-01-01

    With the design and development of the Orbital Maneuvering Vehicle (OMV) progressing toward an early 1990 initial operating capability (IOC), a new era in remote space operations will evolve. The logical progression to OMV front end kits would make available in situ satellite servicing, repair, and consummables resupply to the satellite community. Several conceptual design study efforts are defining representative kits (propellant tanks, debris recovery, module servicers); additional focus must also be placed on an efficient combination module servicer and consummables resupply kit. A remote servicer kit of this type would be designed to perform many of the early maintenance/resupply tasks in both nominal and high inclination orbits. The kit would have the capability to exchange Orbital Replacement Units (ORUs), exchange propellant tanks, and/or connect fluid transfer umbilicals. Necessary transportation system functions/support could be provided by interfaces with the OMV, Shuttle (STS), or Expendable Launch Vehicle (ELV). Specific remote servicer kit designs, as well as ground and flight demonstrations of servicer technology are necessary to prepare for the potential overwhelming need. Ground test plans should adhere to the component/system/breadboard test philosophy to assure maximum capability of one-g testing. The flight demonstration(s) would most likely be a short duration, Shuttle-bay experiment to validate servicer components requiring a micro-g environment.

  15. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  16. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  17. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  18. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  19. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  20. Full-Scale Experimental Verification of Soft-Story-Only Retrofits of Wood-Frame Buildings using Hybrid Testing

    Treesearch

    Elaina Jennings; John W. van de Lindt; Ershad Ziaei; Pouria Bahmani; Sangki Park; Xiaoyun Shao; Weichiang Pang; Douglas Rammer; Gary Mochizuki; Mikhail Gershfeld

    2015-01-01

    The FEMA P-807 Guidelines were developed for retrofitting soft-story wood-frame buildings based on existing data, and the method had not been verified through full-scale experimental testing. This article presents two different retrofit designs based directly on the FEMA P-807 Guidelines that were examined at several different seismic intensity levels. The...

  1. Glider kits cut truck costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1984-02-01

    Trucks used for the delivery of coal have a relatively limited life because they must be specified for somewhat less than brute strength in order to achieve maximum payload within existing weight and length limitations. The major drive train components such as engine, transmission, and drive axles can last longer if rebuilt or remanufactured periodically. For that reason glider kits and other truck components ready for the installation of the drive chain are becoming increasingly popular. These kits have been available for many years, but were regarded only as a means of salvaging late model wrecks or burned trucks. Theirmore » recent acceptance as a means of periodic fleet updating is built around the low cost and immediate availability of remanufactured major components. The cost advantages in using these glider kits are discussed.« less

  2. Building America Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings, Albany, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of buildingmore » air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.« less

  3. Radotinib induces high cytotoxicity in c-KIT positive acute myeloid leukemia cells.

    PubMed

    Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk

    2017-06-05

    Previously, we reported that radotinib, a BCR-ABL1 tyrosine kinase inhibitor, induced cytotoxicity in acute myeloid leukemia (AML) cells. However, the effects of radotinib in the subpopulation of c-KIT-positive AML cells were unclear. We observed that low-concentration radotinib had more potent cytotoxicity in c-KIT-positive cells than c-KIT-negative cells from AML patients. To address this issue, cell lines with high c-KIT expression, HEL92.1.7, and moderate c-KIT expression, H209, were selected. HEL92.1.7 cells were grouped into intermediate and high c-KIT expression populations. The cytotoxicity of radotinib against the HEL92.1.7 cell population with intermediate c-KIT expression was not different from that of the population with high c-KIT expression. When H209 cells were grouped into c-KIT expression-negative and c-KIT expression-positive populations, radotinib induced cytotoxicity in the c-KIT-positive population, but not the c-KIT-negative population. Thus, radotinib induces cytotoxicity in c-KIT-positive cells, regardless of the c-KIT expression intensity. Therefore, radotinib induces significant cytotoxicity in c-KIT-positive AML cells, suggesting that radotinib is a potential target agent for the treatment of c-KIT-positive malignancies including AML. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Viability of Carbon Capture and Sequestration Retrofits for Existing Coal-Fired Power Plants under an Emission Trading Scheme.

    PubMed

    Talati, Shuchi; Zhai, Haibo; Morgan, M Granger

    2016-12-06

    Using data on the coal-fired electric generating units (EGUs) in Texas we assess the economic feasibility of retrofitting existing units with carbon capture and sequestration (CCS) in order to comply with the Clean Power Plan's rate-based emission standards under an emission trading scheme. CCS with 90% capture is shown to be more economically attractive for a range of existing units than purchasing emission rate credits (ERCs) from a trading market at an average credit price above $28 per MWh under the final state standard and $35 per MWh under the final national standard. The breakeven ERC trading prices would decrease significantly if the captured CO 2 were sold for use in enhanced oil recovery, making CCS retrofits viable at lower trading prices. The combination of ERC trading and CO 2 use can greatly reinforce economic incentives and market demands for CCS and hence accelerate large-scale deployment, even under scenarios with high retrofit costs. Comparing the levelized costs of electricity generation between CCS retrofits and new renewable plants under the ERC trading scheme, retrofitting coal-fired EGUs with CCS may be significantly cheaper than new solar plants under some market conditions.

  5. LEM-CF Premixed Tool Kit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-01-19

    The purpose of LEM-CF Premixed Tool Kit is to process premixed flame simulation data from the LEM-CF solver (https://fileshare.craft-tech.com/clusters/view/lem-cf) into a large-eddy simulation (LES) subgrid model database. These databases may be used with a user-defined-function (UDF) that is included in the Tool Kit. The subgrid model UDF may be used with the ANSYS FLUENT flow solver or other commercial flow solvers.

  6. Thermal and health outcomes of energy efficiency retrofits of homes of older adults.

    PubMed

    Ahrentzen, S; Erickson, J; Fonseca, E

    2016-08-01

    Mitigation of thermal stress and adverse indoor climatic conditions is important to older low-income populations whose age, health, and economic circumstances make them vulnerable to indoor environmental conditions. This research examines whether energy retrofits in affordable housing for older adults can also improve indoor climatic (i.e., temperature, humidity, air infiltration) conditions and whether such improvements correspond with improved health and comfort of residents. An apartment complex for low-income older adults in Phoenix was the study site. In 2010, renovations were undertaken to make it more energy efficient and to replace interior cabinetry, flooring, and paint with materials that had low or no volatile organic compounds (VOCs). Fifty-seven residents from 53 apartment units participated in both baseline (pre-renovation) and 1 year post-renovation data collection trials. Environmental measures included temperature, relative humidity, and air infiltration. Health measures included general health, emotional distress, and sleep. Four questions addressed residents' perceptions of temperature quality. Results demonstrated a 19% reduction in energy consumption following the retrofit. In addition, fixed effects statistical models of the panel data showed significant stabilization of unit temperature from pre-retrofit to 1 year post-retrofit. Reductions in an apartment's temperature extremes of 27.2°C (81°F) and above also corresponded with improvement in occupant's reported health over the same time period, although not with occupant's perceptions of thermal comfort. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Differential Use of Elementary Science Kits

    ERIC Educational Resources Information Center

    Jones, Gail; Robertson, Laura; Gardner, Grant E.; Dotger, Sharon; Blanchard, Margaret R.

    2012-01-01

    The use of kits in elementary science classes is a growing trend in some countries. Kits provide materials and inquiry lessons in a ready-to-teach format for teachers to use in their science instruction. This study examined elementary teachers' instructional strategies, classroom practices, and assessment types in relation to the frequency of…

  8. Retrofit of hollow concrete masonry infilled steel frames using glass fiber reinforced plastic laminates

    NASA Astrophysics Data System (ADS)

    Hakam, Zeyad Hamed-Ramzy

    2000-11-01

    This study focuses on the retrofit of hollow concrete masonry infilled steel frames subjected to in-plane lateral loads using glass fiber reinforced plastic (GFRP) laminates that are epoxy-bonded to the exterior faces of the infill walls. An extensive experimental investigation using one-third scale modeling was conducted and consisted of two phases. In the first phase, 64 assemblages, half of which were retrofitted, were tested under various combined in-plane loading conditions similar to those which different regions of a typical infill wall are subjected to. In the second phase, one bare and four masonry-infilled steel frames representative of a typical single-story, single-bay panel were tested under diagonal loading to study the overall behavior and the infill-frame interaction. The relative infill-to-frame stiffness was varied as a test parameter by using two different steel frame sections. The laminates altered the failure modes of the masonry assemblages and reduced the variability and anisotropic nature of the masonry. For the prisms which failed due to shear and/or mortar joint slip, significant strength increases were observed. For those exhibiting compression failure modes, a marginal increase in strength resulted. Retrofitting the infilled frames resulted in an average increase in initial stiffness of two-fold compared to the unretrofitted infilled frames, and seemed independent of the relative infill-to-frame stiffness. However, the increase in the load-carrying capacity of the retrofitted frames compared to the unretrofitted counterparts was higher for those with the larger relative infill-to-frame stiffness parameter. Unlike the unretrofitted infill walls, the retrofitted panels demonstrated almost identical failure modes that were characterized as "strictly comer crushing" in the vicinity of the loaded comers whereas no signs of distress were evident throughout the remainder of the infill. The laminates also maintained the structural integrity of

  9. Liquid balance monitoring inside conventional, Retrofit, and bio-reactor landfill cells.

    PubMed

    Abichou, Tarek; Barlaz, Morton A; Green, Roger; Hater, Gary

    2013-10-01

    The Outer Loop landfill bioreactor (OLLB) in Louisville, KY, USA has been the site of a study to evaluate long-term bioreactor performance at a full-scale operational landfill. Three types of landfill units were studied including a conventional landfill (Control cell), a new landfill area that had an air addition and recirculation piping network installed as waste was being placed (As-Built cell), and a conventional landfill that was modified to allow for liquids recirculation (Retrofit cell). During the monitoring period, the Retrofit, Control, and As-Built cells received 48, 14, and 213LMg(-1) (liters of liquids per metric ton of waste), respectively. The leachate collection system yielded 60, 57 and 198LMg(-1) from the Retrofit, Control, and As-Built cells, respectively. The head on liner in all cells was below regulatory limits. In the Control and As-Built cells, leachate head on liner decreased once waste placement stopped. The measured moisture content of the waste samples was consistent with that calculated from the estimate of accumulated liquid by the liquid balance. Additionally, measurements on excavated solid waste samples revealed large spatial variability in waste moisture content. The degree of saturation in the Control cells decreased from 85% to 75%. The degree of saturation increased from 82% to 83% due to liquids addition in the Retrofit cells and decreased back to 80% once liquid addition stopped. In the As-Built cells, the degree of saturation increased from 87% to 97% during filling activities and then started to decrease soon after filling activities stopped to reach 92% at the end of the monitoring period. The measured leachate generation rates were used to estimate an in-place saturated hydraulic conductivity of the MSW in the range of 10(-8) to 10(-7)ms(-1) which is lower than previous reports. In the Control and Retrofit cells, the net loss in liquids, 43 and 12LMg(-1), respectively, was similar to the measured settlement of 15% and 5

  10. A Path to Successful Energy Retrofits: Early Collaboration through Integrated Project Delivery Teams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parrish, Kristen

    2012-10-01

    This document guides you through a process for the early design phases of retrofit projects to help you mitigate frustrations commonly experienced by building owners and designers. It outlines the value of forming an integrated project delivery team and developing a communication and information-sharing infrastructure that fosters collaboration. This guide does not present a complete process for designing an energy retrofit for a building. Instead, it focuses on the early design phase tasks related to developing and selecting energy efficiency measures (EEMs) that benefit from collaboration, and highlights the resulting advantages.

  11. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    NASA Astrophysics Data System (ADS)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of

  12. Honors for the Virtual Frog Dissection Kit

    Science.gov Websites

    Honors for the Virtual Frog Dissection Kit Study Web The dissection kit received a StudyWeb award Frog Project | Virtual Frog Page last modified: 01/23/05 Contacts: Bill Johnston, David Robertson

  13. c-Kit modifies the inflammatory status of smooth muscle cells.

    PubMed

    Song, Lei; Martinez, Laisel; Zigmond, Zachary M; Hernandez, Diana R; Lassance-Soares, Roberta M; Selman, Guillermo; Vazquez-Padron, Roberto I

    2017-01-01

    c-Kit is a receptor tyrosine kinase present in multiple cell types, including vascular smooth muscle cells (SMC). However, little is known about how c-Kit influences SMC biology and vascular pathogenesis. High-throughput microarray assays and in silico pathway analysis were used to identify differentially expressed genes between primary c-Kit deficient (Kit W/W-v ) and control (Kit +/+ ) SMC. Quantitative real-time RT-PCR and functional assays further confirmed the differences in gene expression and pro-inflammatory pathway regulation between both SMC populations. The microarray analysis revealed elevated NF-κB gene expression secondary to the loss of c-Kit that affects both the canonical and alternative NF-κB pathways. Upon stimulation with an oxidized phospholipid as pro-inflammatory agent, c-Kit deficient SMC displayed enhanced NF-κB transcriptional activity, higher phosphorylated/total p65 ratio, and increased protein expression of NF-κB regulated pro-inflammatory mediators with respect to cells from control mice. The pro-inflammatory phenotype of mutant cells was ameliorated after restoring c-Kit activity using lentiviral transduction. Functional assays further demonstrated that c-Kit suppresses NF-κB activity in SMC in a TGFβ-activated kinase 1 (TAK1) and Nemo-like kinase (NLK) dependent manner. Our study suggests a novel mechanism by which c-Kit suppresses NF-κB regulated pathways in SMC to prevent their pro-inflammatory transformation.

  14. DEVELOPMENT OF AN IDENTIFICATION KIT FOR SPILLED HAZARDOUS MATERIALS

    EPA Science Inventory

    The Chemical Systems Laboratory (CSL) has developed a field kit to identify spilled hazardous materials in inland waters and on the ground. The Hazardous Materials Spills Identification Kit is a two-component kit consisting of an inverter/shortwave UV lamp unit for photochemical ...

  15. The FLEXTRA kit: a model for instructor support materials.

    PubMed

    Battles, J B; Sheridan, M M

    1989-01-01

    The FLEXTRA Kit is a model for the development of resource materials to support instructor-delivered continuing education. Each FLEXTRA Kit consists of camera-ready copy of handout materials; presentation slides, overheads, videotapes, etc.; evaluation instruments; and an instructor's guide. The FLEXTRA Kit is packaged in such a way that it can be easily shipped and stored. Desktop publishing makes the production of FLEXTRA Kits a cost-effective means of providing support to repeated and locally variable training events.

  16. Comparison of presumptive blood test kits including hexagon OBTI.

    PubMed

    Johnston, Emma; Ames, Carole E; Dagnall, Kathryn E; Foster, John; Daniel, Barbara E

    2008-05-01

    Four presumptive blood tests, Hexagon OBTI, Hemastix(R), Leucomalachite green (LMG), and Kastle-Meyer (KM) were compared for their sensitivity in the identification of dried bloodstains. Stains of varying blood dilutions were subjected to each presumptive test and the results compared. The Hexagon OBTI buffer volume was also reduced to ascertain whether this increased the sensitivity of the kit. The study found that Hemastix(R) was the most sensitive test for trace blood detection. Only with the reduced buffer volume was the Hexagon OBTI kit as sensitive as the LMG and KM tests. However, the Hexagon OBTI kit has the advantage of being a primate specific blood detection kit. This study also investigated whether the OBTI buffer within the kit could be utilized for DNA profiling after presumptive testing. The results show that DNA profiles can be obtained from the Hexagon OBTI kit buffer directly.

  17. RETROFIT STORMWATER MANAGEMENT: NAVIGATING MULTIDISCIPLINARY HURDLES AT THE WATERSHED SCALE

    EPA Science Inventory

    Stormwater runoff from extensive impervious surfaces in urban and suburban areas has led to human safety risks and stream ecosystem impairment, triggering an interest in watershed-scale retrofit stormwater management. Such stormwater management is of multidisciplinary relevance, ...

  18. Building Use Policies. SPEC Kit 144.

    ERIC Educational Resources Information Center

    Coyle, Patrick

    This Systems and Procedures Exchange Center (SPEC) flyer/kit addresses some of the needs of Association of Research Libraries (ARL) members regarding library building use and the aesthetics and well-being of the materials and people in the building. The kit draws upon documents gathered as part of a 1986 Quick-SPEC survey that dealt with food and…

  19. Germline mutations of KIT in gastrointestinal stromal tumor (GIST) and mastocytosis.

    PubMed

    Ke, Hengning; Kazi, Julhash U; Zhao, Hui; Sun, Jianmin

    2016-01-01

    Somatic mutations of KIT are frequently found in mastocytosis and gastrointestinal stromal tumor (GIST), while germline mutations of KIT are rare, and only found in few cases of familial GIST and mastocytosis. Although ligand-independent activation is the common feature of KIT mutations, the phenotypes mediated by various germline KIT mutations are different. Germline KIT mutations affect different tissues such as interstitial cells of Cajal (ICC), mast cells or melanocytes, and thereby lead to GIST, mastocytosis, or abnormal pigmentation. In this review, we summarize germline KIT mutations in familial mastocytosis and GIST and discuss the possible cellular context dependent transforming activity of KIT mutations.

  20. Loss of c-KIT expression in thyroid cancer cells.

    PubMed

    Franceschi, Sara; Lessi, Francesca; Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria

    2017-01-01

    Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression.

  1. Loss of c-KIT expression in thyroid cancer cells

    PubMed Central

    Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria

    2017-01-01

    Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression. PMID:28301608

  2. Statistical modeling of dental unit water bacterial test kit performance.

    PubMed

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  3. Evaluation of RC Bridge Piers Retrofitted using Fiber-Reinforced Polymer (FRP)

    NASA Astrophysics Data System (ADS)

    Shayanfar, M. A.; Zarrabian, M. S.

    2008-07-01

    For many long years, steel reinforcements have been considered as the only tool for concrete confinements and studied widely, but nowadays application of Fiber Reinforced Polymer (FRP) as an effective alternative is well appreciated. Many bridges have been constructed in the past that are necessary to be retrofitted for resisting against the earthquake motions. The objective of this research is evaluation of nonlinear behavior of RC bridge piers. Eight RC bridge piers have been modeled by ABAQUS software under micromechanical model for homogeneous anisotropic fibers. Also the Bilinear Confinement Model by Nonlinear Transition Zone of Mirmiran has been considered. Then types and angles of fibers and their effects on the final responses were evaluated [1]. Finally, effects of retrofitting are evaluated and some suggestions presented.

  4. c-Kit modifies the inflammatory status of smooth muscle cells

    PubMed Central

    Song, Lei; Martinez, Laisel; Zigmond, Zachary M.; Hernandez, Diana R.; Lassance-Soares, Roberta M.; Selman, Guillermo

    2017-01-01

    Background c-Kit is a receptor tyrosine kinase present in multiple cell types, including vascular smooth muscle cells (SMC). However, little is known about how c-Kit influences SMC biology and vascular pathogenesis. Methods High-throughput microarray assays and in silico pathway analysis were used to identify differentially expressed genes between primary c-Kit deficient (KitW/W–v) and control (Kit+/+) SMC. Quantitative real-time RT-PCR and functional assays further confirmed the differences in gene expression and pro-inflammatory pathway regulation between both SMC populations. Results The microarray analysis revealed elevated NF-κB gene expression secondary to the loss of c-Kit that affects both the canonical and alternative NF-κB pathways. Upon stimulation with an oxidized phospholipid as pro-inflammatory agent, c-Kit deficient SMC displayed enhanced NF-κB transcriptional activity, higher phosphorylated/total p65 ratio, and increased protein expression of NF-κB regulated pro-inflammatory mediators with respect to cells from control mice. The pro-inflammatory phenotype of mutant cells was ameliorated after restoring c-Kit activity using lentiviral transduction. Functional assays further demonstrated that c-Kit suppresses NF-κB activity in SMC in a TGFβ-activated kinase 1 (TAK1) and Nemo-like kinase (NLK) dependent manner. Discussion Our study suggests a novel mechanism by which c-Kit suppresses NF-κB regulated pathways in SMC to prevent their pro-inflammatory transformation. PMID:28626608

  5. c-kit+ Cells Minimally Contribute Cardiomyocytes to the Heart

    PubMed Central

    van Berlo, Jop H.; Kanisicak, Onur; Maillet, Marjorie; Vagnozzi, Ronald J.; Karch, Jason; Lin, Suh-Chin J.; Middleton, Ryan C.; Marbán, Eduardo; Molkentin, Jeffery D.

    2014-01-01

    If and how the heart regenerates after an injury event is highly debated. c-kit-expressing cardiac progenitor cells have been reported as the primary source for generation of new myocardium after injury. Here we generated two genetic approaches in mice to examine if endogenous c-kit+ cells contribute differentiated cardiomyocytes to the heart during development, with aging or after injury in adulthood. A cDNA encoding either Cre recombinase or a tamoxifen inducible MerCreMer chimeric protein was targeted to the Kit locus in mice and then bred with reporter lines to permanently mark cell lineage. Endogenous c-kit+ cells did produce new cardiomyocytes within the heart, although at a percentage of ≈0.03% or less, and if a preponderance towards cellular fusion is considered, the percentage falls below ≈0.008%. In contrast, c-kit+ cells amply generated cardiac endothelial cells. Thus, endogenous c-kit+ cells can generate cardiomyocytes within the heart, although likely at a functionally insignificant level. PMID:24805242

  6. Protein kinase C-δ-mediated recycling of active KIT in colon cancer.

    PubMed

    Park, Misun; Kim, Won Kyu; Song, Meiying; Park, Minhee; Kim, Hyunki; Nam, Hye Jin; Baek, Sung Hee; Kim, Hoguen

    2013-09-15

    Abnormal signaling through receptor tyrosine kinase (RTK) moieties is important in tumorigenesis and drug targeting of colorectal cancers. Wild-type KIT (WT-KIT), a RTK that is activated upon binding with stem cell factor (SCF), is highly expressed in some colon cancers; however, little is known about the functional role of SCF-dependent KIT activation in colon cancer pathogenesis. We aimed to elucidate the conditions and roles of WT-KIT activation in colon cancer tumorigenesis. Colorectal cancers with KIT expression were characterized by immunoblotting and immunohistochemistry. The biologic alterations after KIT-SCF binding were analyzed with or without protein kinase C (PKC) activation. We found that WT-KIT was expressed in a subset of colon cancer cell lines and was activated by SCF, leading to activation of downstream AKT and extracellular signal-regulated kinase (ERK) signaling pathways. We also showed that KIT expression gradually decreased, after prolonged SCF stimulation, due to lysosomal degradation. Degradation of WT-KIT after SCF binding was significantly rescued when PKC was activated. We also showed the involvement of activated PKC-δ in the recycling of WT-KIT. We further showed that a subset of colorectal cancers exhibit expressions of both WT-KIT and activated PKC-δ and that expression of KIT is correlated with poor patient survival (P = 0.004). Continuous downstream signal activation after KIT-SCF binding is accomplished through PKC-δ-mediated recycling of KIT. This sustained KIT activation may contribute to tumor progression in a subset of colon cancers with KIT expression and might provide the rationale for a therapeutic approach targeting KIT. ©2013 AACR.

  7. KiT: a MATLAB package for kinetochore tracking.

    PubMed

    Armond, Jonathan W; Vladimirou, Elina; McAinsh, Andrew D; Burroughs, Nigel J

    2016-06-15

    During mitosis, chromosomes are attached to the mitotic spindle via large protein complexes called kinetochores. The motion of kinetochores throughout mitosis is intricate and automated quantitative tracking of their motion has already revealed many surprising facets of their behaviour. Here, we present 'KiT' (Kinetochore Tracking)-an easy-to-use, open-source software package for tracking kinetochores from live-cell fluorescent movies. KiT supports 2D, 3D and multi-colour movies, quantification of fluorescence, integrated deconvolution, parallel execution and multiple algorithms for particle localization. KiT is free, open-source software implemented in MATLAB and runs on all MATLAB supported platforms. KiT can be downloaded as a package from http://www.mechanochemistry.org/mcainsh/software.php The source repository is available at https://bitbucket.org/jarmond/kit and under continuing development. Supplementary data are available at Bioinformatics online. jonathan.armond@warwick.ac.uk. © The Author 2016. Published by Oxford University Press.

  8. Low-cost field test kits for arsenic detection in water.

    PubMed

    Das, Joyati; Sarkar, Priyabrata; Panda, Jigisha; Pal, Priyabrata

    2014-01-01

    Arsenic, a common contaminant of groundwater, affects human health adversely. According to the World Health Organization (WHO), the maximum recommended contamination level of arsenic in drinking water is 10 μg/L. The purpose of this research was to develop user-friendly kits for detection of arsenic to measure at least up to 10 μg/L in drinking water, so that a preventive measure could be taken. Two different kits for detection of total arsenic in water are reported here. First, the arsenic in drinking water was converted to arsine gas by a strong reducing agent. The arsine produced was then detected by paper strips via generation of color due to reaction with either mercuric bromide (KIT-1) or silver nitrate (KIT-2). These were previously immobilized on the detector strip. The first one gave a yellow color and the second one grey. Both of these kits could detect arsenic contamination within a range of 10 μg/L-250 μg/L. The detection time for both the kits was only 7 min. The kits exhibited excellent performance compared to other kits available in the market with respect to detection time, ease of operation, cost and could be easily handled by a layman. The field trials with these kits gave very satisfactory results. A study on interference revealed that these kits could be used in the presence of 24 common ions present in the arsenic contaminated water. Though the kits were meant for qualitative assay, the results with unknown concentrations of real samples, when compared with atomic absorption spectrophotometer (AAS) were in good agreement as revealed by the t-test.

  9. Energy and Cost Savings of Retro-Commissioning and Retrofit Measures for Large Office Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Weimin; Zhang, Jian; Moser, Dave

    2012-08-03

    This paper evaluates the energy and cost savings of seven retro-commissioning measures and 29 retrofit measures applicable to most large office buildings. The baseline model is for a hypothetical building with characteristics of large office buildings constructed before 1980. Each retro-commissioning measure is evaluated against the original baseline in terms of its potential of energy and cost savings while each retrofit measure is evaluated against the commissioned building. All measures are evaluated in five locations (Miami, Las Vegas, Seattle, Chicago and Duluth) to understand the impact of weather conditions on energy and cost savings. The results show that implementation ofmore » the seven operation and maintenance measures as part of a retro-commissioning process can yield an average of about 22% of energy use reduction and 14% of energy cost reduction. Widening zone temperature deadband, lowering VAV terminal minimum air flow set points and lighting upgrades are effective retrofit measures to be considered.« less

  10. Performance-Based Seismic Retrofit of Soft-Story Woodframe Buildings Using Energy-Dissipation Systems

    NASA Astrophysics Data System (ADS)

    Tian, Jingjing

    Low-rise woodframe buildings with disproportionately flexible ground stories represent a significant percentage of the building stock in seismically vulnerable communities in the Western United States. These structures have a readily identifiable structural weakness at the ground level due to an asymmetric distribution of large openings in the perimeter wall lines and to a lack of interior partition walls, resulting in a soft story condition that makes the structure highly susceptible to severe damage or collapse under design-level earthquakes. The conventional approach to retrofitting such structures is to increase the ground story stiffness. An alternate approach is to increase the energy dissipation capacity of the structure via the incorporation of supplemental energy dissipation devices (dampers), thereby relieving the energy dissipation demands on the framing system. Such a retrofit approach is consistent with a Performance-Based Seismic Retrofit (PBSR) philosophy through which multiple performance levels may be targeted. The effectiveness of such a retrofit is presented via examination of the seismic response of a full-scale four-story building that was tested on the outdoor shake table at NEES-UCSD and a full-scale three-story building that was tested using slow pseudo-dynamic hybrid testing at NEES-UB. In addition, a Direct Displacement Design (DDD) methodology was developed as an improvement over current DDD methods by considering torsion, with or without the implementation of damping devices, in an attempt to avoid the computational expense of nonlinear time-history analysis (NLTHA) and thus facilitating widespread application of PBSR in engineering practice.

  11. Feasibility of Retrofitting Lifts on Commuter and Light Rail Vehicles

    DOT National Transportation Integrated Search

    1980-09-01

    The objectives of this study were to determine if lift retrofit applications to rail vehicles are technically feasible, and if so, the extent to which existing bus lift technology can be utilized. This report examines some of the technical issues ass...

  12. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  13. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  14. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  15. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  16. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  17. Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  18. Spatial Distribution and Receptor Specificity of Zebrafish Kit System - Evidence for a Kit-Mediated Bi-Directional Communication System in the Preovulatory Ovarian Follicle

    PubMed Central

    Yao, Kai; Ge, Wei

    2013-01-01

    Consisting of Kit ligand and receptor Kit, the Kit system is involved in regulating many ovarian functions such as follicle activation, granulosa cell proliferation, and oocyte growth and maturation. In mammals, Kit ligand is derived from the granulosa cells and Kit receptor is expressed in the oocyte and theca cells. In the zebrafish, the Kit system contains two ligands (Kitlga and Kitlgb) and two receptors (Kita and Kitb). Interestingly, Kitlga and Kitb are localized in the somatic follicle cells, but Kitlgb and Kita are expressed in the oocyte. Using recombinant zebrafish Kitlga and Kitlgb, we demonstrated that Kitlga preferentially activated Kita whereas Kitlgb specifically activated Kitb by Western analysis for receptor phosphorylation. In support of this, Kitlgb triggered a stronger and longer MAPK phosphorylation in follicle cells than Kitlga, whereas Kitlga but not Kitlgb activated MAPK in the denuded oocytes, in agreement with the distribution of Kita and Kitb in the follicle and their specificity for Kitlga and Kitlgb. Further analysis of the interaction between Kit ligands and receptors by homology modeling showed that Kitlga-Kita and Kitlgb-Kitb both have more stable electrostatic interaction than Kitlgb-Kita or Kitlga-Kitb. A functional study of Kit involvement in final oocyte maturation showed that Kitlga and Kitlgb both suppressed the spontaneous maturation significantly; in contrast, Kitlgb but not Kitlga significantly promoted 17α, 20β-dihydroxy-4-pregnen-3-one (DHP) -induced oocyte maturation. Our results provided strong evidence for a Kit-mediated bi-directional communication system in the zebrafish ovarian follicle, which could be part of the complex interplay between the oocyte and the follicle cells in the development of follicles. PMID:23409152

  19. SAFL Baffle retrofit for suspended sediment removal in storm sewer sumps.

    PubMed

    Howard, Adam; Mohseni, Omid; Gulliver, John; Stefan, Heinz

    2011-11-15

    Standard sumps (manholes) provide a location for pipe junctions and maintenance access in stormwater drainage systems. Standard sumps can also remove sand and silt particles from stormwater, but have a high propensity for washout of the collected sediment. With appropriate maintenance these sumps may qualify as a stormwater best management practice (BMP) device for the removal of suspended sediment from stormwater runoff. To decrease the maintenance frequency and prevent standard sumps from becoming a source of suspended sediment under high flow conditions, a porous baffle, named the SAFL Baffle, has been designed and tested as a retrofit to the sump. Multiple configurations with varying percent open area and different angles of attack were evaluated in scale models. An optimum configuration was then constructed at the prototype scale and evaluated for both removal efficiency and washout. Results obtained with the retrofit indicate that with the right baffle dimensions and porosity, sediment washout from the sump at high flow rates can be almost eliminated, and removal efficiency can be significantly increased at low flow rates. Removal efficiency and washout functions have been developed for standard sumps retrofitted with the SAFL Baffle. The results of this research provide a new, versatile stormwater treatment device and implemented new washout and removal efficiency testing procedures that will improve research and development of stormwater treatment devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Crowne Plaza Renovation Retrofit Case Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    InterContinental Hotels Group (IHG) and its franchise partner B.F. Saul Company Hospitality Group (B.F. Saul Co.) partnered with the Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% versus requirements set by Standard 90.1-2004 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

  1. C-MORE Science Kits as a Classroom Learning Tool

    ERIC Educational Resources Information Center

    Foley, J. M.; Bruno, B. C.; Tolman, R. T.; Kagami, R. S.; Hsia, M. H.; Mayer, B.; Inazu, J. K.

    2013-01-01

    To support teachers in enhancing ocean literacy, the Center for Microbial Oceanography: Research and Education (C-MORE) has developed a series of portable, hands-on science kits on selected topics in oceanography. This paper provides an overview of kit content, describes how the kits were developed, and evaluates their efficacy as a curriculum…

  2. Education kits for fiber optics, optoelectronics, and optical communications

    NASA Astrophysics Data System (ADS)

    Hájek, Martin; Švrček, Miroslav

    2007-04-01

    Our company MIKROKOM, s.r.o. is engaged for many years in development of education equipment and kits for fiber optics, optoelectronics and optical communications. We would like to inform competitors of conference about results of this long-time development. Requirements on education kits and equipment in a modern and dynamic area as is optical communications and fiber optics are quite difficult. The education kits should to clearly introduce students to given issue - the most important physical principles and technical approaches, but it should to introduce also to new and modern technologies, which are quickly changing and developing. On the other hand should be these tools and kits reasonable for the schools. In our paper we would like to describe possible ways of development of this education kits and equipment and present our results of long-time work, which covers very wide range. On the one hand we developed equipment and kits for clear demonstration of physical effects using plastic optical fibers POF, next we prepare kits with a glass fibers, which are the most used fibers in practice and after as much as the kits, which covers broad range of passive and active elements of the optical networks and systems and which makes possible to create complex optical transmission connection. This kind of systems with using corresponding tools and equipment introduce the students to properties, manipulation, measurement and usage of optical fibers, traces and many active and passive components. Furthermore, with using different sorts of optical sources, photodetectors, fiber optics couplers etc., students can get acquainted with all optoelectronics transmission system, which uses different sorts of signals. Special part will be devoted also to effort mentioned before - to implement modern technologies such as e.g. Wavelength Division Multiplex (WDM) into the education kits. Our presentation will inform auditors about development of mentioned education kits and

  3. New capabilities for older aircraft: A study of pilot integration of retro-fit digital avionics to analog-instrumented flight decks

    NASA Astrophysics Data System (ADS)

    Breuer, Glynn E.

    The purpose of this study was to determine whether applying Gilbert's Behavior Engineering Model to military tactical aviation organizations would foster effective user integration of retro-fit digital avionics in analog-instrumented flight decks. This study examined the relationship between the reported presence of environmental supports and personal repertory supports as defined by Gilbert, and the reported self-efficacy of users of retro-fit digital avionics to analog flight decks, and examined the efficacious behaviors of users as they attain mastery of the equipment and procedures, and user reported best practices and criteria for masterful performance in the use of retro-fit digital avionics and components. This study used a mixed methodology, using quantitative surveys to measure the perceived level of organizational supports that foster mastery of retro-fit digital avionic components, and qualitative interviews to ascertain the efficacious behaviors and best practices of masterful users of these devices. The results of this study indicate that there is some relationship between the reported presence of organizational supports and personal repertory supports and the reported self-mastery and perceived organizational mastery of retro-fit digital avionics applied to the operation of the research aircraft. The primary recommendation is that unit leadership decide exactly the capabilities desired from retro-fit equipment, publish these standards, ensure training in these standards is effective, and evaluate performance based on these standards. Conclusions indicate that sufficient time and resources are available to the individual within the study population, and the organization as a whole, to apply Gilbert's criteria toward the mastery of retro-fit digital avionics applied to the operation of the research aircraft.

  4. 49 CFR 214.517 - Retrofitting of existing on-track roadway maintenance machines manufactured on or after January 1...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Retrofitting of existing on-track roadway maintenance machines manufactured on or after January 1, 1991. 214.517 Section 214.517 Transportation Other... Retrofitting of existing on-track roadway maintenance machines manufactured on or after January 1, 1991. In...

  5. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthesia conduction kit. 868.5140 Section 868.5140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a...

  6. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthesia conduction kit. 868.5140 Section 868.5140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a...

  7. Load rating and FRP retrofitting of bridge abutment timber piles.

    DOT National Transportation Integrated Search

    2016-05-01

    This report details Phase II of the study titled Strengthening of Bridge Wood Piling Retrofits for Moment Resistance. Phase I of the research (project : R27-082) was focused on developing a load rating method for timber piles under eccentric load and...

  8. Association of KIT exon 9 mutations with nongastric primary site and aggressive behavior: KIT mutation analysis and clinical correlates of 120 gastrointestinal stromal tumors.

    PubMed

    Antonescu, Cristina R; Sommer, Gunhild; Sarran, Lisa; Tschernyavsky, Sylvia J; Riedel, Elyn; Woodruff, James M; Robson, Mark; Maki, Robert; Brennan, Murray F; Ladanyi, Marc; DeMatteo, Ronald P; Besmer, Peter

    2003-08-15

    Activating mutations of the KIT juxtamembrane region are the most common genetic events in gastrointestinal stromal tumors (GISTs) and have been noted as independent prognostic factors. The impact of KIT mutation in other regions, such as the extracellular or kinase domains, is not well-defined and fewer than 30 cases have been published to date. One hundred twenty GISTs, confirmed by KIT immunoreactivity, were evaluated for the presence of KIT exon 9, 11, 13, and 17 mutations. The relation between the presence/type of KIT mutation and clinicopathological factors was analyzed using Fisher's exact test and log-rank test. Forty-four % of the tumors were located in the stomach, 47% in the small bowel, 6% in the rectum, and 3% in the retroperitoneum. Overall, KIT mutations were detected in 78% of patients as follows: 67% in exon 11, 11% in exon 9, and none in exon 13 or 17. The types of KIT exon 11 mutations were heterogeneous and clustered in the classic "hot spot" at the 5' end of exon 11. Seven % of cases showed internal tandem duplications (ITD) at the 3' end of exon 11, in a region that we designate as a second hot spot for KIT mutations. Interestingly, these cases were associated with: female predominance, stomach location, occurrence in older patients, and favorable outcome. There were significant associations between exon 9 mutations and large tumor size (P < 0.001) and extragastric location (P = 0.02). Ten of these 13 patients with more than 1-year follow-up have developed recurrent disease. Most KIT-expressing GISTs show KIT mutations that are preferentially located within the classic hot spot of exon 11. In addition, we found an association between a second hot spot at the 3'end of exon 11, characterized by ITDs, and a subgroup of clinically indolent gastric GISTs in older females. KIT exon 9 mutations seem to define a distinct subset of GISTs, located predominantly in the small bowel and associated with an unfavorable clinical course.

  9. Home Pregnancy Test Kits: How Readable Are the Instructions?

    ERIC Educational Resources Information Center

    Holcomb, Carol Ann

    At the conclusion of their study on home pregnancy test kits, Valinas and Perlman (1982) suggested that the instructions accompanying the kits be revised to make them easier to read. A study was undertaken to determine the readability of the printed instructions accompanying five home pregnancy test kits (Daisy II, Answer, Acu-Test, Predictor, and…

  10. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  11. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  12. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  13. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  14. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  15. Independent evaluation of the transit retrofit package safety applications : final report.

    DOT National Transportation Integrated Search

    2015-02-01

    This report presents the methodology and results of the independent evaluation of retrofit safety packages installed on transit vehicles in the : Safety Pilot Model Deploymentpart of the United States Department of Transportations Intelligent T...

  16. Social Housing Policies and Best Practice Review for Retrofit Action - Case Studies from Parma (IT)

    NASA Astrophysics Data System (ADS)

    Gherri, Barbara; Cavagliano, Chiara; Orsi, Samuele

    2017-10-01

    The paper aims at investigating the most suitable Energy Saving Measures -ESMs- for the retrofitting of Social Housing Stock -SHS- in Europe. A global awareness has been increasing, as well as education and training among architects and building sectors employees, in order to identify tailored financing schemes and advanced integrated retrofitting solutions. Several European financed programmes have been tested so far and the results are here summarized and deeply investigated in order to increase the energy performance of social housing buildings, to improve knowledge of problems associated with the retrofitting of these households, in order to provide the most appropriate solutions to be applied. Afterward, the best practices selected have been applied to some study cases in Italy, to demonstrate that the large variety of SH programmes in Europe can seriously be used, promoting the best practises’ application. A lot of theoretical and analytical work has been carried out by many European projects in the last decade, defining different approaches according to typologies of social housing buildings, focusing on national or regional regulation, on existing typologies and building techniques, on retrofitting solutions, on energy saving strategies and other managing approaches and energy saving devices. Due to the high participation of social housing organisations -SHO- and related European financed programmes, this academic research is focused on the most effective ESMs in order to encompass a large variety of needs and related solutions, even though some of them are still on course and other ones have already been completed. This research clearly demonstrates the valuable contribution these kinds of programme have in exchanging and sharing of knowledge and experience in the field of retrofit of Social Housing building across Europe, in order to primary improve the energy performance of the existing building stock and the quality of life of their inhabitants.

  17. Working with Self-Injurious Adolescents Using the Safe Kit

    ERIC Educational Resources Information Center

    Moyer, Michael

    2008-01-01

    This article offers a guide for using the Safe Kit when working with clients who self-injure. The Safe Kit can be used as a supplement to more traditional approaches to counseling and offers clients alternatives to self-injury when they need alternatives the most. The Safe Kit works under the assumption that individuals differ in the meaning they…

  18. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The U.S. Department of Energy developed the K-12 Advanced Energy Retrofit Guide to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. We emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluation of the most promising retrofit measure for each building type. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings.

  19. Vulnerability Assessment of Shelters in the Eastern Caribbean: Retrofitting Terms of Reference for Consultants, Standards, [and] Global Estimates.

    ERIC Educational Resources Information Center

    Gibbs, Tony

    Dozens of natural disaster shelters (mostly schools) in five Caribbean islands were assessed as to their vulnerability and the needed retrofitting to upgrade them. This report provides retrofit consultants with terms of reference and building design criteria for withstanding various natural disasters, as well as estimated global costs of various…

  20. 75 FR 37456 - Green Retrofit Program of Title XII of the American Recovery and Reinvestment Act of 2009

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-29

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5376-N-55] Green Retrofit Program of Title XII of the American Recovery and Reinvestment Act of 2009 AGENCY: Office of the Chief Information... Title of Proposal: Green Retrofit Program of Title XII of the American Recovery and Reinvestment Act of...

  1. Identification of mutations in the coding sequence of the proto-oncogene c-kit in a human mast cell leukemia cell line causing ligand-independent activation of c-kit product.

    PubMed Central

    Furitsu, T; Tsujimura, T; Tono, T; Ikeda, H; Kitayama, H; Koshimizu, U; Sugahara, H; Butterfield, J H; Ashman, L K; Kanayama, Y

    1993-01-01

    The c-kit proto-oncogene encodes a receptor tyrosine kinase. Binding of c-kit ligand, stem cell factor (SCF) to c-kit receptor (c-kitR) is known to activate c-kitR tyrosine kinase, thereby leading to autophosphorylation of c-kitR on tyrosine and to association of c-kitR with substrates such as phosphatidylinositol 3-kinase (PI3K). In a human mast cell leukemia cell line HMC-1, c-kitR was found to be constitutively phosphorylated on tyrosine, activated, and associated with PI3K without the addition of SCF. The expression of SCF mRNA transcript in HMC-1 cells was not detectable by means of PCR after reverse transcription (RT-PCR) analysis, suggesting that the constitutive activation of c-kitR was ligand independent. Sequencing of whole coding region of c-kit cDNA revealed that c-kit genes of HMC-1 cells were composed of a normal, wild-type allele and a mutant allele with two point mutations resulting in intracellular amino acid substitutions of Gly-560 for Val and Val-816 for Asp. Amino acid sequences in the regions of the two mutations are completely conserved in all of mouse, rat, and human c-kit. In order to determine the causal role of these mutations in the constitutive activation, murine c-kit mutants encoding Gly-559 and/or Val-814, corresponding to human Gly-560 and/or Val-816, were constructed by site-directed mutagenesis and expressed in a human embryonic kidney cell line, 293T cells. In the transfected cells, both c-kitR (Gly-559, Val-814) and c-kitR (Val-814) were abundantly phosphorylated on tyrosine and activated in immune complex kinase reaction in the absence of SCF, whereas tyrosine phosphorylation and activation of c-kitR (Gly-559) or wild-type c-kitR was modest or little, respectively. These results suggest that conversion of Asp-816 to Val in human c-kitR may be an activating mutation and responsible for the constitutive activation of c-kitR in HMC-1 cells. Images PMID:7691885

  2. No GIST-type c-kit gain of function mutations in neuroblastic tumours

    PubMed Central

    Korja, M; Finne, J; Salmi, T T; Haapasalo, H; Tanner, M; Isola, J

    2005-01-01

    Aims: Neuroblastic tumours (NTs) have been shown to respond to imatinib treatment in vivo and in vitro, possibly via inactivating the c-kit receptor. The purpose of this study was to identify gastrointestinal stromal tumour (GIST)-type c-kit gene associated mutations in exons 9, 11, 13, and 17 in NTs to recognise a subset of tumours that would probably respond to imatinib treatment. Methods: Expression of the c-kit protein was detected immunohistochemically in a total of 37 archival paraffin wax embedded NTs using polyclonal rabbit antihuman c-kit antibody. After immunohistochemistry, c-kit gene associated chromosomal mutations in all cases of NT were detected with denaturing high performance liquid chromatography (HPLC). Results: Denaturing HLPC analysis did not reveal GIST-type mutations in four immunohistochemically detected c-kit positive or in 33 c-kit negative NTs. Conclusions: c-kit receptor expression and GIST-type c-kit gene mutations are rare events in NTs. Oncogenic activation of c-kit in NTs presumably differs from that of GISTs, which may influence their responsiveness to imatinib treatment. Whether c-kit has an essential role in the pathogenesis of NTs remains to be investigated. PMID:15976348

  3. A Demonstration of a Retrofit Architecture for Intelligent Control and Diagnostics of a Turbofan Engine

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan S.; Turso, James A.; Shah, Neerav; Sowers, T. Shane; Owen, A. Karl

    2005-01-01

    A retrofit architecture for intelligent turbofan engine control and diagnostics that changes the fan speed command to maintain thrust is proposed and its demonstration in a piloted flight simulator is described. The objective of the implementation is to increase the level of autonomy of the propulsion system, thereby reducing pilot workload in the presence of anomalies and engine degradation due to wear. The main functions of the architecture are to diagnose the cause of changes in the engine s operation, warning the pilot if necessary, and to adjust the outer loop control reference signal in response to the changes. This requires that the retrofit control architecture contain the capability to determine the changed relationship between fan speed and thrust, and the intelligence to recognize the cause of the change in order to correct it or warn the pilot. The proposed retrofit architecture is able to determine the fan speed setting through recognition of the degradation level of the engine, and it is able to identify specific faults and warn the pilot. In the flight simulator it was demonstrated that when degradation is introduced into an engine with standard fan speed control, the pilot needs to take corrective action to maintain heading. Utilizing the intelligent retrofit control architecture, the engine thrust is automatically adjusted to its expected value, eliminating yaw without pilot intervention.

  4. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with the oral tissues. After the denture base is constructed, the connected preformed teeth are...: Evaluation and Testing,’ ” and (2) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits...

  5. Dowel bar retrofit evaluation, district 12, Orange County, Interstate 405

    DOT National Transportation Integrated Search

    2002-09-01

    A dowel bar retrofit project on Interstate 405 near Irvine in Orange County began to exhibit sights of failure in the bond between the existing concrete and the backfill grout in the dowel bar slots. It was requested the Office of Rigid Pavement and ...

  6. Phylogenetic diversity of microorganisms in subseafloor crustal fluids from Holes 1025C and 1026B along the Juan de Fuca Ridge flank

    PubMed Central

    Jungbluth, Sean P.; Lin, Huei-Ting; Cowen, James P.; Glazer, Brian T.; Rappé, Michael S.

    2014-01-01

    To expand investigations into the phylogenetic diversity of microorganisms inhabiting the subseafloor biosphere, basalt-hosted crustal fluids were sampled from Circulation Obviation Retrofit Kits (CORKs) affixed to Holes 1025C and 1026B along the Juan de Fuca Ridge (JdFR) flank using a clean fluid pumping system. These boreholes penetrate the crustal aquifer of young ocean crust (1.24 and 3.51 million years old, respectively), but differ with respect to borehole depth and temperature at the sediment-basement interface (147 m and 39°C vs. 295 m and 64°C, respectively). Cloning and sequencing of PCR-amplified small subunit ribosomal RNA genes revealed that fluids retrieved from Hole 1025C were dominated by relatives of the genus Desulfobulbus of the Deltaproteobacteria (56% of clones) and Candidatus Desulforudis of the Firmicutes (17%). Fluids sampled from Hole 1026B also contained plausible deep subseafloor inhabitants amongst the most abundant clone lineages; however, both geochemical analysis and microbial community structure reveal the borehole to be compromised by bottom seawater intrusion. Regardless, this study provides independent support for previous observations seeking to identify phylogenetic groups of microorganisms common to the deep ocean crustal biosphere, and extends previous observations by identifying additional lineages that may be prevalent in this unique environment. PMID:24723917

  7. Special tool kit aids heavily garmented workers

    NASA Technical Reports Server (NTRS)

    Holmes, A. E.

    1966-01-01

    Triangular aluminum tool kit, filled with polyurethane is constructed to receive various tools and hold them in a snug but quick-release fit as an aid to heavily gloved workers. The kit is designed to allow mounting within easily accessable reach and to provide protection of the tools during storage.

  8. Review of retrofit strategies decision system in historic perspective

    NASA Astrophysics Data System (ADS)

    Bostenaru Dan, M. D.

    2004-06-01

    Urban development is a process. In structuring and developing its phases different actors are implied, who act under different, sometimes opposite, dynamic conditions and within different reference systems. This paper aims to explore the contribution of participatism to disaster mitigation, when this concerns earthquake impact on urban settlements, through the support provided to multi-criteria decision in matters of retrofit. The research broadness in field of decision making on one side and the lack of a specific model for the retrofit of existing buildings on another side led to an extensive review of the state of the art in related models to address the issue. Core idea in the selection of existing models has been the preoccupation for collaborative issues, in other words, the consideration for the different actors implied in the planning process. The historic perspective on participative planning models is made from the view of two generations of citizen implication. The first approaches focus on the participation of the building owner/inhabitant in the planning process of building construction. As current strategies building rehabilitation and selection from alternative retrofit strategies are presented. New developments include innovative models using the internet or spatial databases. The investigated participation approaches show, that participation and communication as a more comprehensive term are an old topic in the field politics-democratisation-urbanism. In all cases it can be talked of "successful learning processes", of the improvement of the level of the professional debate. More than 30 years history of participation marked a transition in understanding the concept: from participation, based on a central decision process leading to a solution controlled and steered by the political-administrative system, to communication, characterised by simultaneous decision processes taking place outside politics and administration in co-operative procedures.

  9. Dry-running gas seals save $200,000/yr in retrofit hydrogen recycle compressor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pennacchi, R.P.; Germain, A.

    1987-10-01

    Texaco Chemical Company was using three drums of oil per day in the seal oil system of a hydrogen recycle compressor, resulting in maintenance and operational expenses of more than $160,000 per year. Running 24 hours/day, 365 days/yr, the 26-yr-old compressor is the heart of the benzene manufacturing process unit at the Port Arthur, Texas plant. In the event of an unscheduled shutdown, the important aromatics unit process would halt and cause production losses of thousands of dollars per day. In addition, the close monitoring and minimization of leakage are essential since the gas consists of over 75% hydrogen, withmore » methane, ethane, propane, isobutane, N-butane and pentanes. Texaco Chemical Company decided that retrofit of the hydrogen recycle compressor should be undertaken if the system could be developed to sharply reduce operations and maintenance costs, and increase efficiencies. Texaco engineers selected a dry running-type gas sealing system developed for pipeline compressors in the United States, Canada, and overseas. A tandem-type sealing system was designed to meet specific needs of a hydrogen recycle compressor. The retrofit was scheduled for August 1986 to coincide with the plant's preventative maintenance program. The seal system installation required five days. The retrofit progressed according to schedule, with no problems experienced at the first and several startups since the initial installation. Oil consumption has been eliminated, along with seal support and parasitic energy requirements. With the savings in seal oil, energy, operations and maintenance, payback period for the retrofit sealing system was just over six months. Savings are expected to continue at an annual rate of over $200,000.« less

  10. HNU-HANBY PCP IMMUNOASSAY TEST KIT - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The HNU-Hanby pentachlorophenol (PCP) test kit rapidly analyzes for PCP in soil samples. The test kit can only detect those PCP carriers that contain aromatic compounds. The test kit estimates PCP concentrations in soil samples indirectly by measuring petroleum hydrocarbon carrie...

  11. Applying energy-conservation retrofits to standard army buildings: project design and initial energy data. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westervelt, E.T.; Northrup, G.R.; Allen, E.O.

    1988-07-01

    This report describes the initial and continuing efforts in a project demonstrating the energy performance of theoretically-based retrofit packages on as-found, standard-design Army buildings. Four standard building designs are being investigated: a motor-vehicle repair shop, the Type 64 (L-shaped) barracks, an enlisted-personnel mess hall, and a two-company, rolling-pin-shaped barracks for enlisted personnel. The Army has over 840 of these particular buildings. The objective of the project is to test the energy and cost performance of the retrofit packages, which include such measures as installing wall or ceiling insulation, replacing and/or blocking windows, partitioning areas of differing temperature, modifying air-handling equipment,more » modifying boiler controls, replacing lights, etc. To this end, energy data has been gathered from retrofitted and identical but nonretrofitted buildings for a test/reference comparison.« less

  12. Impact evaluation of lighting retrofit projects at Boeing Commercial Airplane Group under The Energy $avings Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, G.P.; Oens, M.A.; Spanner, G.E.

    1994-01-01

    This impact evaluation of two lighting retrofit projects that were recently installed at Boeing Commercial Airplane Group (Boeing) was conducted for the Bonneville Power Administration (Bonneville) as part of an evaluation of its Energy $avings Plan (E$P) Program. The first project was a light-fixture and lighting control retrofit, consisting of five individual measures installed in Building 40-05. The second project was a retrofit of all parking lot lighting on the site. The objective of this impact evaluation was to assess how much electrical energy is being saved at Boeing as a result of the E$P projects and to determine howmore » much the savings cost Bonneville and the region. The impact of the project was evaluated with a combination of engineering analysis, financial analysis, interviews, and submittal reviews (Boeing`s proposals and completion reports).« less

  13. Blood collection kit for Space Lab 1

    NASA Image and Video Library

    1981-02-02

    S81-26158 (Feb 1981) --- A close-up view of a training version of a STS-40/SLS-1 blood kit. Blood samples from crewmembers are critical to a number of Space Life Sciences-1 (SLS-1) investigations. One day's collection equipment, color coded for each crewmember, is neatly organized in the kit.

  14. miR-137 downregulates c-kit expression in acute myeloid leukemia.

    PubMed

    Hu, Yanping; Dong, Xiaolong; Chu, Guoming; Lai, Guangrui; Zhang, Bijun; Wang, Leitong; Zhao, Yanyan

    2017-06-01

    The oncogene c-kit plays a vital role in the pathogenesis of acute myeloid leukemia (AML). However, the mechanism of microRNAs targeting c-kit in AML has not been determined in detail. Moreover, the role miR-137 in tumor cell proliferation remains controversial. The aim of this work was to verify whether miR-137 targets c-kit and to research the biological effects of restoring miR-137 expression in leukemia cells. We found that miR-137 binds specifically to the 3'-UTR of c-kit and suppresses the expression and activities of c-kit. There is a negative correlation between miR-137 and c-kit expression in both patients and cell lines determined by screening large clinical samples. We found that miR-137 can inhibit proliferation, promote apoptosis, and induce differentiation of c-kit+ AML cells. We determined that miR-137 can participate in the leukemogenesis by regulating c-kit, which could be used as a therapeutic target for acute myeloid leukemia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake

    NASA Astrophysics Data System (ADS)

    Cimellaro, Gian Paolo; Reinhorn, Andrei M.; de Stefano, Alessandro

    2011-03-01

    The 2009 L'Aquila, Italy earthquake highlighted the seismic vulnerability of historic masonry building structures due to improper "strengthening" retrofit work that has been done in the last 50 years. Italian seismic standards recommend the use of traditional reinforcement techniques such as replacing the original wooden roof structure with new reinforced concrete (RC) or steel elements, inserting RC tie-beams in the masonry and new RC floors, and using RC jacketing on the shear walls. The L'Aquila earthquake revealed the numerous limitations of these interventions, because they led to increased seismic forces (due to greater additional weight) and to deformation incompatibilities of the incorporated elements with the existing masonry walls. This paper provides a discussion of technical issues pertaining to the seismic retrofit of the Santa Maria di Collemaggio Basilica and in particular, the limitations of the last (2000) retrofit intervention. Considerable damage was caused to the church because of questionable actions and incorrect and improper technical choices.

  16. Pseudo-dynamic tests on masonry residential buildings seismically retrofitted by precast steel reinforced concrete walls

    NASA Astrophysics Data System (ADS)

    Li, Wenfeng; Wang, Tao; Chen, Xi; Zhong, Xiang; Pan, Peng

    2017-07-01

    A retrofitting technology using precast steel reinforced concrete (PSRC) panels is developed to improve the seismic performance of old masonry buildings. The PSRC panels are built up as an external PSRC wall system surrounding the existing masonry building. The PSRC walls are well connected to the existing masonry building, which provides enough confinement to effectively improve the ductility, strength, and stiffenss of old masonry structures. The PSRC panels are prefabricated in a factory, significantly reducing the situ work and associated construction time. To demonstrate the feasibility and mechanical effectivenss of the proposed retrofitting system, a full-scale five-story specimen was constructed. The retrofitting process was completed within five weeks with very limited indoor operation. The specimen was then tested in the lateral direction, which could potentially suffer sigifnicant damage in a large earthquake. The technical feasibility, construction workability, and seismic performance were thoroughly demonstrated by a full-scale specimen construction and pseudo-dynamic tests.

  17. Retrofit and acceptance test of 30-cm ion thrusters

    NASA Technical Reports Server (NTRS)

    Poeschel, R. L.

    1981-01-01

    Six 30 cm mercury thrusters were modified to the J-series design and evaluated using standardized test procedures. The thruster performance meets the design objectives (lifetime objective requires verification), and documentation (drawings, etc.) for the design is completed and upgraded. The retrofit modifications are described and the test data for the modifications are presented and discussed.

  18. Slab replacement and dowel bar retrofit, district 11, San Diego County

    DOT National Transportation Integrated Search

    2002-01-01

    The project Resident Engineer requested that the Office of Rigid Pavement Materials and Structural Concrete examine cracking in replacement slabs and dowel bar retrofit installations on a project rehabilitating a section of Route 08 in District 11 ne...

  19. [Development of surgical antibioprophylaxis kits: evaluation of the impact on prescribing habits].

    PubMed

    Aouizerate, P; Guizard, M

    2002-01-01

    In our hospital, surgical antibioprophylaxis (ATBP) was too often administered too late, thus raising the infectious risk. Antibiotic stocks of the anaesthesia department were also systematically used, instead of nominal prescriptions of these drugs. The pharmacy could neither charge antibiotics to each surgical department nor quantify and differentiate ATBP from curative antibiotic therapy. The pharmacy and anaesthesia departments therefore set out to standardize surgical ATBP, in order to adapt this treatment to each surgical indication, and particularly in the case of allergy to beta-lactamase antibiotics (second line treatment kits). Consequently, prescription forms were developed and supplied to each surgery department, as well as ATBP kits. The kits were prepared and distributed by the pharmacy, and comprised boxes containing antibiotics in sufficient quantities to respect the protocols approved by the French Society of Anaesthesia and Resuscitation (SFAR). A protocol describing prescriptions, dispensation and administration has been presented to physicians and nurses. Fifteen surgical departments were included in our study and 30 different kits were prepared. From 1998 to 2001, 5586 surgical operations required administration of a kit (second line treatment kits in 5% of cases): 1848 (33%) in visceral surgery; 764 (13.8%) in urology; 802 (14%) in orthopaedics; 13 (0.2%) in vascular and thoracic surgery; 1236 (22%) in ear-nose-throat (ENT), periodontics and ophtalmology, and 923 (17%) in gynaecology and obstetrics. 93% of filled prescriptions forms were spontaneously returned to the pharmacy, the others were obtained during the renewal of kit stocks. The cost (over 4 years) of ATBP was quantified: 157,871 F for the 15 departments included, 26,123 F in visceral surgery, 13,520 F in urology, 73,741 F in orthopaedics, 569 F in vascular surgery, 39,720 F in ENT/ophthalmology/periodontics and 4,198 F in gynaecology and obstetrics. According to the Altemeier

  20. Technology Solutions Case Study: Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Basements in climates 6 & 7 can account for a fraction of a home's total heat loss when fully conditioned. These foundations are a source of moisture, with convection in open block cavities redistributing water from the wall base, usually when heating. Even when block cavities are capped, the cold foundation concrete can act as a moisture source for wood rim joist components that are in contact with the wall. As below-grade basements are increasingly retrofitted for habitable space, cold foundation walls pose increased challenges for moisture durability, energy use, and occupant comfort. To address this challenge, the NorthernSTAR Buildingmore » America Partnership evaluated a retrofit insulation strategy for foundations that is designed for use with open-core concrete block foundation walls. The three main goals were to improve moisture control, improve occupant comfort, and reduce heat loss.« less

  1. Next Step Toward Widespread Residential Deep Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McIlvaine, J.; Saunders, S.; Bordelon, E.

    The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

  2. The Use of Kits in the Analysis of Tissue Lipids Requires Validation.

    PubMed

    Rider, T; LeBoeuf, R C; Tso, Patrick; Jandacek, R J

    2016-04-01

    The ready availability and ease of use of kits for the measurement of serum lipids has greatly facilitated these measurements. In many cases it would be convenient to use these kits in the determination of lipid concentrations in tissues. The successful application of serum kits in tissue analysis requires that two important issues be considered. First, the solvent system for the extraction of the lipids and the solvent used for analysis by the kit must be compatible with the reactions in the kit. Second, the concentration range in the analyzed solution must be within the range for which the kit is used. We report here that lipids in liver and adipose tissues may be significantly underestimated by the use of some kits. We recommend that the use of kits for tissue analysis of lipids be validated for the specific analysis.

  3. Effects of Retrofitting Emission Control Systems on all In-Use Heavy Diesel Trucks

    NASA Astrophysics Data System (ADS)

    Millstein, D.; Harley, R. A.

    2009-12-01

    Diesel exhaust is now the largest source of nitrogen oxide (NOx) emissions nationally in the US, and contributes significantly to emissions of fine particulate black carbon (soot) as well. New national standards call for dramatically lower emissions of exhaust particulate matter (PM) and NOx from new diesel engines starting in 2007 and 2010, respectively. Unfortunately it will take decades for the cleaner new engines to replace those currently in service on existing heavy-duty trucks. The state of California recently adopted a rule to accelerate fleet turnover in the heavy-duty truck sector, requiring that all in-use trucks meet the new exhaust PM standards by 2014. This will entail retrofit of diesel particle filters or replacement for over a million existing diesel engines. Diesel particle filters can replace the muffler on existing trucks, and there is extensive experience with retrofit of this control equipment on public sector fleets such as diesel-powered transit buses. Nitrogen dioxide (NO2) is used as an oxidizing agent to remove carbon particles from the particle filter, to prevent it from becoming plugged. To create the needed NO2, NOx already present in engine exhaust as nitric oxide (NO) is deliberately oxidized to NO2 upstream of the particle filter using a platinum catalyst. The NO2/NOx ratio in exhaust emissions therefore increases to ~35% in comparison to much lower values (~5%) typical of older engines without particle filters. We evaluate the effects on air quality of increased use of diesel particle traps and NOx controls in southern California using the Community Multiscale Air Quality (CMAQ) model. Compared to a reference scenario without the retrofit program, we found black carbon concentrations decreased by ~20%, with small increases (4%) in ambient ozone concentrations. During summer, average NO2 concentrations decrease despite the increase in primary NO2 emissions - because total NOx emissions are reduced as part of a parallel but more

  4. Implementation of retrofit BMPs in a suburban watershed via economic incentives

    EPA Science Inventory

    Urban stormwater is typically conveyed to centralized infrastructure, and there is great potential for reducing stormwater runoff quantity through decentralization. In this case we hypothesize that smaller-scale retrofit best management practices (BMPs) such as rain gardens and r...

  5. The value of molecular expression of KIT and KIT ligand analysed using real-time polymerase chain reaction and immunohistochemistry as a prognostic indicator for canine cutaneous mast cell tumours.

    PubMed

    Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M

    2015-03-01

    This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.

  6. Nociceptive tuning by stem cell factor/c-Kit signaling.

    PubMed

    Milenkovic, Nevena; Frahm, Christina; Gassmann, Max; Griffel, Carola; Erdmann, Bettina; Birchmeier, Carmen; Lewin, Gary R; Garratt, Alistair N

    2007-12-06

    The molecular mechanisms regulating the sensitivity of sensory circuits to environmental stimuli are poorly understood. We demonstrate here a central role for stem cell factor (SCF) and its receptor, c-Kit, in tuning the responsiveness of sensory neurons to natural stimuli. Mice lacking SCF/c-Kit signaling displayed profound thermal hypoalgesia, attributable to a marked elevation in the thermal threshold and reduction in spiking rate of heat-sensitive nociceptors. Acute activation of c-Kit by its ligand, SCF, resulted in a reduced thermal threshold and potentiation of heat-activated currents in isolated small-diameter neurons and thermal hyperalgesia in mice. SCF-induced thermal hyperalgesia required the TRP family cation channel TRPV1. Lack of c-Kit signaling during development resulted in hypersensitivity of discrete mechanoreceptive neuronal subtypes. Thus, c-Kit can now be grouped with a small family of receptor tyrosine kinases, including c-Ret and TrkA, that control the transduction properties of sensory neurons.

  7. Directional and Attitude Stability Control Kit

    DTIC Science & Technology

    2014-07-01

    Pre-MRAP Vehicle Rollover Stats1 7/6/2014 DASK - Directional and Attitude Stability Control Kit 7 1: Joint Military Vehicle Working Group Army... contained in this report are those of the author(s) and should not contrued as an official Department of the Army position, policy or decision, unless so...Control Kit 3 8/14/2012 9 Statement of Problem Studied • We address the problem of maneuver-induced rollovers of ground vehicles in theatre. A bolt

  8. Receptor tyrosine kinase (c-Kit) inhibitors: a potential therapeutic target in cancer cells

    PubMed Central

    Abbaspour Babaei, Maryam; Kamalidehghan, Behnam; Saleem, Mohammad; Huri, Hasniza Zaman; Ahmadipour, Fatemeh

    2016-01-01

    c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit for future cancer therapy. In addition, it has c-Kit inhibitor drug properties and their functions have been listed in tables and demonstrated in schematic pictures. This review also has collected previous studies that targeted c-Kit as a novel strategy for cancer therapy. This paper further emphasizes the advantages of this approach, as well as the limitations that must be addressed in the future. Finally, although c-Kit is an attractive target for cancer therapy, based on the outcomes of treatment of patients with c-Kit inhibitors, it is unlikely that Kit inhibitors alone can lead to cure. It seems that c-Kit mutations alone are not sufficient for tumorogenesis, but do play a crucial role in cancer occurrence. PMID:27536065

  9. Sustainable wall construction and exterior insulation retrofit technology process and structure

    DOEpatents

    Vohra, Arun

    2000-01-01

    A low-cost process for exterior wall insulation retrofit, or new wall construction by stacking layers of fabric tube filled with insulating material against a wall and covering them with mesh and stucco provides a durable structure with good insulating value.

  10. Evaluating the Dynamic Characteristics of Retrofitted RC Beams

    NASA Astrophysics Data System (ADS)

    Ghods, Amir S.; Esfahani, Mohamad R.; Moghaddasie, Behrang

    2008-07-01

    The aim of this experimental study was to investigate the relationship between the damage and changes in dynamic characteristics of reinforced concrete members strengthened with Carbon Fiber Reinforced Polymer (CFRP). Modal analysis is a popular non-destructive method for evaluating health of structural systems. A total of 8 reinforced concrete beams with similar dimensions were made using concrete with two different compressive strengths and reinforcement ratios. Monotonic loading was applied with four-point-bending setup in order to generate different damage levels in the specimens while dynamic testing was conducted to monitor the changes in dynamic characteristics of the specimens. In order to investigate the effect of CFRP on static and dynamic properties of specimens, some of the beams were loaded to half of their ultimate load carrying capacity and then were retrofitted using composite laminates with different configuration. Retrofitted specimens demonstrated elevated load carrying capacity, higher flexural stiffness and lower displacement ductility. By increasing the damage level in specimens, frequencies of the beams were decreased and after strengthening these values were improved significantly. The intensity of the damage level in each specimen affects the shape of its mode as well. Fixed points and curvatures of mode shapes of beams tend to move toward the location of the damage in each case.

  11. Cost-effectiveness of a ROPS retrofit education campaign.

    PubMed

    Myers, M L; Cole, H P; Westneat, S C

    2004-05-01

    A community educational campaign implemented in two Kentucky counties was effective in influencing farmers to retrofit their tractors with rollover protective structures (ROPS) to protect tractor operators from injury in the event of an overturn. This article reports on the cost-effectiveness of this program in the two counties when compared to no program in a control county. A decision analysis indicated that it would be effective at averting 0.27 fatal and 1.53 nonfatal injuries over a 20-year period, and when this analysis was extended statewide, 7.0 fatal and 40 nonfatal injuries would be averted in Kentucky. Over the 20-year period, the cost-per-injury averted was calculated to be $172,657 at a 4% annual discount rate. This cost compared favorably with a national cost of $489,373 per injury averted despite the additional program cost in Kentucky. The principle reason for the increased cost-effectiveness of the Kentucky program was the three-fold higher propensity for tractors to overturn in Kentucky. The cost-per-injury averted in one of the two counties was $112,535. This lower cost was attributed principally to incentive awards financed locally for farmers to retrofit their tractors with ROPS.

  12. Vietnamese Culture Kit.

    ERIC Educational Resources Information Center

    Nguyen, Liem Thanh

    This booklet provides a brief description of the cultural background of the Vietnamese, the geography of the country of Vietnam, the history of the Vietnamese people, their language, beliefs, systems of values, religions, customs, feasts, and holidays. The kit is designed to provide American sponsors and teachers with meaningful information about…

  13. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  14. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  15. Exploration of the assessment practices of elementary teachers using science kits

    NASA Astrophysics Data System (ADS)

    Scribner-Maclean, Michelle

    The purpose of the study was to determine the assessment literacy levels of elementary teachers who are experienced science kit users compared to those who are novice users as well as to compare assessment literacy levels of kit users to non kit users. Further, the study explored how teachers used assessment instruments in a classroom setting during kit-based science lessons. The study consisted of two parts. The population for Part One of this study was 47 elementary teachers from four communities in Northeastern Massachusetts who used Science, Technology, and Children (STC) kits for their classroom science instruction. Part Two of this study was conducted with four elementary teachers, two experienced kit users and two novice kit users, who were selected by their administrators. Data were collected for Part One of this study by use of the Teacher Assessment Questionnaire (TAQ), developed by Plake and Impara (1990), which provided a description of the assessment literacy levels of teachers. The assessment literacy levels of experienced kit users were compared to novice kit users by the t-Test for independent means. The assessment literacy levels of kit users and non kit users were also compared by use of the t-Test for independent means. For Part Two, classroom observations and teacher interviews were audio taped and transcribed. Each of these four teachers were also given the TAQ. Data for Part Two of the study were categorized and coded by Whittington's (1990) assessment literacy skills which are based upon the Standards for Teacher Competency of Educational Assessment of Students (STCEAS). Instances in which these skills occurred during classroom observations and pre- and post-lesson interviews were tabulated to create an overall picture of assessment literacy for each of the four teachers. The findings for Parts One and Two of this study indicate that there were differences in the assessment literacy scores for kit users and non kit users only for Standard Two

  16. Supply kits for antenatal and childbirth care: a systematic review.

    PubMed

    Aleman, Alicia; Tomasso, Giselle; Cafferata, María Luisa; Colomar, Mercedes; Betran, Ana Pilar

    2017-12-13

    It is critical to increase the uptake of interventions proven to be effective to improve maternal and perinatal outcomes. Supply kits have been suggested to be a feasible strategy designed to ensure timely availability and effective follow-up of care. We conducted a systematic review to summarize the evidence on the uptake, effectiveness and safety of supply kits for maternal care. MEDLINE, the Cochrane Pregnancy and Childbirth Group's Trials Register, Campbell Collaboration, Lilacs, Embase and unpublished studies were searched. Studies that reported the efficacy, safety and use of supply kits for maternal healthcare were eligible. Participants were pregnant women or in childbirth. Supply kits were defined as a collection of medicines, supplies or instruments packaged together with the aim of conducting a healthcare task. Two reviewers independently performed the screening, data extraction, and methodological and quality assessment. 24 studies were included: 4 of them were systematic reviews and 20 primary studies. Eighteen studies evaluated a so-called "clean delivery kit". In all but two studies, the kits were used by more than half of the participants. A meta-analysis was deemed inappropriate due to the heterogeneity in study design, in the components of the interventions implemented, in the content of the kits, and in outcomes. Nine studies assessed neonatal outcomes and found statistically significant reductions in cord infection, sepsis and tetanus-related mortality in the intervention group. Three studies showed evidence of reduced neonatal mortality (OR 0.52, 0.60 and 0.71) with statistically significant confidence intervals in all cases. Four studies reported odd ratios for maternal mortality, but only one showed evidence of a statistically significant decrease in this outcome but it was ascribed to hand washing prior to childbirth and not with the use of kits. This review suggests potential benefits in the use of supply kits to improve maternal and

  17. Evaluation of a Commercial Latex Agglutination Test Kit for Cryptococcal Antigen

    PubMed Central

    Kaufman, Leo; Cowart, Glenda; Blumer, Sharon; Stine, Amy; Wood, Ross

    1974-01-01

    Two dozen Crypto-LA kits for detecting Cryptococcus neoformans capsular polysaccharide antigens were evaluated. Ten kits proved reliable for detecting and titering antigen in clinical materials. Fourteen kits were found to be inadequate. PMID:4596394

  18. What Fleets Need to Know About Alternative Fuel Vehicle Conversions, Retrofits, and Repowers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Kay L.; Gonzales, John

    2017-10-17

    Many fleet managers have opted to incorporate alternative fuels and advanced vehicles into their lineup. Original equipment manufacturers (OEMs) offer a variety of choices, and there are additional options offered by aftermarket companies. There are also a myriad of ways that existing vehicles can be modified to utilize alternative fuels and other advanced technologies. Vehicle conversions and retrofit packages, along with engine repower options, can offer an ideal way to lower vehicle operating costs. This can result in long term return on investment, in addition to helping fleet managers achieve emissions and environmental goals. This report summarizes the various factorsmore » to consider when pursuing a conversion, retrofit, or repower option.« less

  19. Whole Foods Market Retrofits Multiple Building Systems for Big Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-03-01

    Whole Foods Market partnered with U.S. the Department of Energy (DOE) to develop and implement solutions to reduce annual energy consumption in existing stores by at least 30% versus pre-retrofit energy use at its store in Edgewater, New Jersey, as part of DOE’s Commercial Building Partnership (CBP) program.

  20. Birth kits for safe motherhood in Bangladesh.

    PubMed

    Nessa, S; Arco, E S; Kabir, I A

    1992-01-01

    Tetanus infection remains the leading cause of high neonatal mortality in Bangladesh. Birth kits which instruct and assist in a clean, safe birth are seen as a key measure in reducing the high incidence of neonatal deaths. A multisectoral programme has developed a simple kit and tested its potential for distribution to pregnant women. Initial results are positive and development is continuing.

  1. The Quality Lighting Teaching Kit: enlightening our future

    NASA Astrophysics Data System (ADS)

    Walker, Constance E.; Pompea, Stephen M.

    2016-09-01

    The U.S. National Optical Astronomy Observatory's Education and Public Outreach group has produced a Quality Lighting Teaching (QLT) Kit, as an outcome of the International Year of Light 2015. The kits are designed around problem-based learning scenarios. The kit's six activities allow students to address real lighting problems that relate to wildlife, sky glow, aging eyes, energy consumption, safety, and light trespass. The activities are optimized for 11-14 year olds but can be expanded to younger and older. Most of the activities can be done within in a few minutes with the exception of the Energy Activity. The activities can be done during class or afterschool and as stations (that the students rotate through) or as stand-alones (one at a time). All aspects of the program are as ready-for-use. Everything you need for the six activities is included in the kit. Tutorial videos (on the program's webpage) have been created on how to do the activities. They can be found on the webpage, www.noao.edu/education/qltkit.php. Fourteen Google+ Hangouts on Air have been offered, addressing questions on the activities and logistics. Assessments (in the form of pre- and post-surveys for the students and as post-surveys for the instructors) provide learning outcomes and improvements. Eighty-nine out of 100 kits have been distributed to SPIE, OSA, CIE, IDA and the IAU in 31 countries. The QLT Kit is a stepping-stone to bring awareness to the (younger) public on how quality lighting locally can redress issues like light pollution globally.

  2. Burn Wise Awareness Kit

    EPA Pesticide Factsheets

    Health and safety outreach materials in the form of an awareness kit. Designed specifically for state, local, and tribal air agencies working to reduce wood smoke pollution, it includes best burn tips, social media m

  3. The FOT tool kit concept

    NASA Technical Reports Server (NTRS)

    Fatig, Michael

    1993-01-01

    Flight operations and the preparation for it has become increasingly complex as mission complexities increase. Further, the mission model dictates that a significant increase in flight operations activities is upon us. Finally, there is a need for process improvement and economy in the operations arena. It is therefore time that we recognize flight operations as a complex process requiring a defined, structured, and life cycle approach vitally linked to space segment, ground segment, and science operations processes. With this recognition, an FOT Tool Kit consisting of six major components designed to provide tools to guide flight operations activities throughout the mission life cycle was developed. The major components of the FOT Tool Kit and the concepts behind the flight operations life cycle process as developed at NASA's GSFC for GSFC-based missions are addressed. The Tool Kit is therefore intended to increase productivity, quality, cost, and schedule performance of the flight operations tasks through the use of documented, structured methodologies; knowledge of past lessons learned and upcoming new technology; and through reuse and sharing of key products and special application programs made possible through the development of standardized key products and special program directories.

  4. Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Del Bianco, M.; Wiehagen, J.

    2013-01-01

    Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit and addressed crawlspace foundations in a mixed-humid climate.

  5. TQAP for Verification of Qualitative Lead Test Kits

    EPA Science Inventory

    There are lead-based paint test kits available to help home owners and contractors identify lead-based paint hazards before any Renovation, Repair, and Painting (RRP) activities take place so that proper health and safety meaures can be enacted. However, many of these test kits ...

  6. Rural inland waterways economic impact kit : users guide

    DOT National Transportation Integrated Search

    2000-08-01

    The primary objective of the project was to develop a PC-based kit allowing users to evaluate the economic impact of existing rural inland waterways ports and terminals. By using the Kit, the importance to a community of a port and terminals can be q...

  7. Rural inland waterways economic impact kit : analysis manual

    DOT National Transportation Integrated Search

    2000-08-01

    The primary objective of the project was to develop a PC-based kit allowing users to evaluate the economic impact of existing rural inland waterways ports and terminals. By using the Kit, the importance to a community of a port and terminals can be q...

  8. Highway Vehicle Retrofit Evaluation : Phase 2. Report. Testing and Final Evaluation Results.

    DOT National Transportation Integrated Search

    1976-11-01

    This report presents the results of engine dynamometer and vehicle chassis dynamometer tests conducted with selected automotive retrofit devices in the classes of ultrasonic carburetors, high-velocity intake manifolds, tuned exhaust systems, and high...

  9. Assessment of Greenhouse Gas Retrofit Issues for Coal Fired Power Plants

    EPA Science Inventory

    Several studies have been published on carbon capture technology as an independent island. In contrast, this evaluation considered the impact on the existing plant and the potential improvements to ease the retrofit of a carbon capture process. This paper will provide insight i...

  10. CASE HISTORY OF FINE PORE DIFFUSER RETROFIT AT RIDGEWOOD, NEW JERSEY

    EPA Science Inventory

    In April 1983, the Ridgewood, New Jersey Wastewater Treatment Plant underwent a retrofit from a coarse bubble to a fine pore aeration system. Also, process modification from contact stabilization to tapered aeration occurred. This report presents a case history of plant and aer...

  11. Third party EPID with IGRT capability retrofitted onto an existing medical linear accelerator

    PubMed Central

    Odero, DO; Shimm, DS

    2009-01-01

    Radiation therapy requires precision to avoid unintended irradiation of normal organs. Electronic Portal Imaging Devices (EPIDs), can help with precise patient positioning for accurate treatment. EPIDs are now bundled with new linear accelerators, or they can be purchased from the Linac manufacturer for retrofit. Retrofitting a third party EPID to a linear accelerator can pose challenges. The authors describe a relatively inexpensive third party CCD camera-based EPID manufactured by TheraView (Cablon Medical B.V.), installed onto a Siemens Primus linear accelerator, and integrated with a Lantis record and verify system, an Oldelft simulator with Digital Therapy Imaging (DTI) unit, and a Philips ADAC Pinnacle treatment planning system (TPS). This system integrates well with existing equipment and its software can process DICOM images from other sources. The system provides a complete imaging system that eliminates the need for separate software for portal image viewing, interpretation, analysis, archiving, image guided radiation therapy and other image management applications. It can also be accessed remotely via safe VPN tunnels. TheraView EPID retrofit therefore presents an example of a less expensive alternative to linear accelerator manufacturers’ proprietary EPIDs suitable for implementation in third world countries radiation therapy departments which are often faced with limited financial resources. PMID:21611056

  12. Third party EPID with IGRT capability retrofitted onto an existing medical linear accelerator.

    PubMed

    Odero, D O; Shimm, D S

    2009-07-01

    Radiation therapy requires precision to avoid unintended irradiation of normal organs. Electronic Portal Imaging Devices (EPIDs), can help with precise patient positioning for accurate treatment. EPIDs are now bundled with new linear accelerators, or they can be purchased from the Linac manufacturer for retrofit. Retrofitting a third party EPID to a linear accelerator can pose challenges. The authors describe a relatively inexpensive third party CCD camera-based EPID manufactured by TheraView (Cablon Medical B.V.), installed onto a Siemens Primus linear accelerator, and integrated with a Lantis record and verify system, an Oldelft simulator with Digital Therapy Imaging (DTI) unit, and a Philips ADAC Pinnacle treatment planning system (TPS). This system integrates well with existing equipment and its software can process DICOM images from other sources. The system provides a complete imaging system that eliminates the need for separate software for portal image viewing, interpretation, analysis, archiving, image guided radiation therapy and other image management applications. It can also be accessed remotely via safe VPN tunnels. TheraView EPID retrofit therefore presents an example of a less expensive alternative to linear accelerator manufacturers' proprietary EPIDs suitable for implementation in third world countries radiation therapy departments which are often faced with limited financial resources.

  13. [Determination of Hair Shafts by InnoTyper® 21 Kit].

    PubMed

    Li, F; Zhang, M; Wang, Y X; Shui, J J; Yan, M; Jin, X P; Zhu, X J

    2017-12-01

    To explore the application value of InnoTyper® 21 kit in forensic practice. Samples of hair shafts and saliva were collected from 8 unrelated individuals. Template DNA was extracted by AutoMate Express™ forensic DNA automatic extraction system. DNA was amplified by InnoTyper® 21 kit and AmpFℓSTR™ Identifiler™ Plus kit, respectively, and then the results were compared. After the amplification by InnoTyper® 21 kit, complete specific genotyping could be detected from the saliva samples, and the peak value of genotyping profiles of hair shafts without sheath cells was 57-1 219 RFU. Allelic gene deletion could be found sometimes. When amplified by AmpFℓSTR™ Identifiler™ Plus kit, complete specific genotyping could be detected from the saliva samples, and the specific fragment was not detected in hair shafts without sheath cells. The InnoTyper® 21 kit has certain application value in the cases of hair shafts without sheath cells. Copyright© by the Editorial Department of Journal of Forensic Medicine

  14. World Disarmament Kit.

    ERIC Educational Resources Information Center

    Woito, Robert, Ed.

    This kit presents a comprehensive introduction for students to arms control and disarmament issues. Included are copies of published and unpublished articles for each topic. Section I provides a self-survey to enable students to assess their own attitudes, values, and knowledge. The survey poses questions for which students select one of several…

  15. Solid phase microextraction field kit

    DOEpatents

    Nunes, Peter J.; Andresen, Brian D.

    2005-08-16

    A field kit for the collection, isolation and concentration of trace amounts of high explosives (HE), biological weapons (BW) and chemical weapons (CW) residues in air, soil, vegetation, swipe, and liquid samples. The field kit includes a number of Solid Phase Microextraction (SPME) fiber and syringe assemblies in a hermetically sealed transportation container or tubes which includes a sampling port, a number of extra SPME fiber and syringe assemblies, the fiber and syringe assemblies including a protective cap for the fiber, and an extractor for the protective cap, along with other items including spare parts, protective glove, and an instruction manual, all located in an airtight container.

  16. Energy-Efficiency Retrofits in Small-Scale Multifamily Rental Housing: A Business Model

    NASA Astrophysics Data System (ADS)

    DeChambeau, Brian

    The goal of this thesis to develop a real estate investment model that creates a financial incentive for property owners to perform energy efficiency retrofits in small multifamily rental housing in southern New England. The medium for this argument is a business plan that is backed by a review of the literature and input from industry experts. In addition to industry expertise, the research covers four main areas: the context of green building, efficient building technologies, precedent programs, and the Providence, RI real estate market for the business plan. The thesis concludes that the model proposed can improve the profitability of real estate investment in small multifamily rental properties, though the extent to which this is possible depends partially on utility-run incentive programs and the capital available to invest in retrofit measures.

  17. The effects of an energy efficiency retrofit on indoor air quality.

    PubMed

    Frey, S E; Destaillats, H; Cohn, S; Ahrentzen, S; Fraser, M P

    2015-04-01

    To investigate the impacts of an energy efficiency retrofit, indoor air quality and resident health were evaluated at a low-income senior housing apartment complex in Phoenix, Arizona, before and after a green energy building renovation. Indoor and outdoor air quality sampling was carried out simultaneously with a questionnaire to characterize personal habits and general health of residents. Measured indoor formaldehyde levels before the building retrofit routinely exceeded reference exposure limits, but in the long-term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long-term follow-up sampling within certain resident subpopulations (i.e. residents who report smoking and residents who had lived longer at the apartment complex). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Preparation of acid-base bifunctional mesoporous KIT-6 (KIT: Korea Advanced Institute of Science and Technology) and its catalytic performance in Knoevenagel reaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Ling; Wang, Chunhua; Guan, Jingqi, E-mail: guanjq@jlu.edu.cn

    2014-05-01

    Acid-base bifunctional mesoporous catalysts Al-KIT-6-NH{sub 2} containing different aluminum content have been synthesized through post synthetic grafting method. The materials were characterized by X-ray diffraction (XRD), scanning electron micrographs (SEM), transmission electron micrographs (TEM), Fourier-transform infrared spectroscopy (FTIR), IR spectra of pyridine adsorption, NH{sub 3}-TPD and TG analysis. The characterization results indicated that the pore structure of KIT-6 was well kept after the addition of aluminum and grafting of aminopropyl groups. The acid amount of Al-KIT-6 increased with enhancing aluminum content. Catalytic results showed that weak acid and weak base favor the Knoevenagel reaction, while catalysts with strong acid andmore » weak base exhibited worse catalytic behavior. - Graphical abstract: The postulated steps of mechanism for the acid-base catalyzed process are as follows: (1) the aldehyde gets activated by the surface acidic sites which allow the amine undergoes nucleophilic to attack the carbonyl carbon of benzaldehyde. (2) Water is released in the formation of imine intermediate. (3) The ethyl cyanoacetate reacts with the intermediate. (4) The benzylidene ethyl cyanoacetate is formed and the amine is regenerated. - Highlights: • KIT-6 and Al-KIT-6-NH{sub 2} with different Si/Al ratios has been successfully prepared. • 79.4% Yield was obtained over 46-Al-KIT-6-NH{sub 2} within 20 min in Knoevenagel reaction. • Low Al-content Al-KIT-6-NH{sub 2} shows better catalytic stability than high Al-content catalysts. • There is acid-base synergistic effect in Knoevenagel reaction.« less

  19. General view, looking northeast. Retrofitted into a garage during the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view, looking northeast. Retrofitted into a garage during the twentieth century, this building dates from very early in the Lazaretto's history and is believed to have once functioned as a summer kitchen or bake house. - Lazaretto Quarantine Station, Kitchen/Bake House, Wanamaker Avenue and East Second Street, Essington, Delaware County, PA

  20. Evaluation of the kinase domain of c-KIT in canine cutaneous mast cell tumors

    PubMed Central

    Webster, Joshua D; Kiupel, Matti; Yuzbasiyan-Gurkan, Vilma

    2006-01-01

    Background Mutations in the c-KIT proto-oncogene have been implicated in the progression of several neoplastic diseases, including gastrointestinal stromal tumors and mastocytosis in humans, and cutaneous mast cell tumors (MCTs) in canines. Mutations in human mastocytosis patients primarily occur in c-KIT exon 17, which encodes a portion of its kinase domain. In contrast, deletions and internal tandem duplication (ITD) mutations are found in the juxtamembrane domain of c-KIT in approximately 15% of canine MCTs. In addition, ITD c-KIT mutations are significantly associated with aberrant KIT protein localization in canine MCTs. However, some canine MCTs have aberrant KIT localization but lack ITD c-KIT mutations, suggesting that other mutations or other factors may be responsible for aberrant KIT localization in these tumors. Methods In order to characterize the prevalence of mutations in the phospho-transferase portion of c-KIT's kinase domain in canine MCTs exons 16–20 of 33 canine MCTs from 33 dogs were amplified and sequenced. Additionally, in order to determine if mutations in c-KIT exon 17 are responsible for aberrant KIT localization in MCTs that lack juxtamembrane domain c-KIT mutations, c-KIT exon 17 was amplified and sequenced from 18 canine MCTs that showed an aberrant KIT localization pattern but did not have ITD c-KIT mutations. Results No mutations or polymorphisms were identified in exons 16–20 of any of the MCTs examined. Conclusion In conclusion, mutations in the phospho-transferase portion of c-KIT's kinase domain do not play an important role in the progression of canine cutaneous MCTs, or in the aberrant localization of KIT in canine MCTs. PMID:16579858

  1. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) (Book)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, B.

    2013-07-01

    The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive marketmore » segments.« less

  2. Retrofit energy studies of a recreation center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haberl, J.S.; Claridge, D.

    1985-01-01

    Retrofit energy options for the Student Recreation Center at the University of Colorado have been evaluated using the DOE-2.1b simulation program. This building has two major systems that are not included in the program - an ice rink and a swimming pool. The approach used to model these systems and the use of the program for other applications not included in the program, such as duty cycling and night cycling of fans for freeze protection, are emphasized. Measures that help streamline the usage of the program on a minicomputer are also discussed.

  3. Evaluation of the Coca-Cola company travel health kit.

    PubMed

    Harper, Lynne A; Bettinger, Julie; Dismukes, Roberta; Kozarsky, Phyllis E

    2002-01-01

    The Coca-Cola travel health kit has been used for about one decade for international travelers and required evaluation to see if the items contained were appropriate for the employees. Two hundred thirty-four travelers were sampled and filled out a voluntary survey including questions about demographic information, travel history, and usage and value of the contents of the travel health kit. One hundred eighty-one surveys were returned; 65% of the respondents were male, and the majority of travelers were between the ages of 36 and 45 years. The most useful items were analgesics and medications used for gastrointestinal problems. In general, the items identified as being the least useful were those requiring specialized use by a medical practitioner, such as needles and syringes. Suggestions of items to be added to the kit included vitamins, cough drops, sleep aids, and eye drops. A surprising result that Coca-Cola employees expressed the desire for brand name rather than generic items. Evaluation of the Coca-Cola Company travel health kit revealed it to be very useful to most corporate travelers. Suggestions that were made will be taken into consideration in designing a new kit, and consideration is being given to whether a basic travel health kit should be provided to which travelers can add other items depending on their personal needs.

  4. Optimal bridge retrofit strategy to enhance disaster resilience of highway transportation systems.

    DOT National Transportation Integrated Search

    2014-07-01

    This study evaluated the resilience of highway bridges under the multihazard scenario of earthquake in the presence of : flood-induced scour. To mitigate losses incurred from bridge damage during extreme events, bridge retrofit strategies are : selec...

  5. KIT pathway alterations in mucosal melanomas of the vulva and other sites.

    PubMed

    Omholt, Katarina; Grafström, Eva; Kanter-Lewensohn, Lena; Hansson, Johan; Ragnarsson-Olding, Boel K

    2011-06-15

    A significant proportion of mucosal melanomas contain alterations in KIT. The aim of this study was to characterize the pattern of KIT, NRAS, and BRAF mutations in mucosal melanomas at specific sites and to assess activation of the KIT downstream RAF/MEK/extracellular signal-regulated kinase (ERK) and phosphoinositide 3-kinase (PI3K)/AKT pathways in mucosal melanoma specimens. Seventy-one primary mucosal melanomas from various sites were studied. Mutation analysis was done by DNA sequencing. Expression of KIT, phosphorylated (p)-ERK, and p-AKT was evaluated by immunohistochemistry. KIT mutations were detected in 35% (8 of 23) of vulvar, 9% (2 of 22) of anorectal, 7% (1 of 14) of nasal cavity, and 20% (1 of 5) of penile melanomas. No KIT mutations were found in 7 vaginal melanomas. The difference in KIT mutation frequency between vulvar and nonvulvar cases was statistically significant (P = 0.014). The overall frequencies of NRAS and BRAF mutations were 10% and 6%, respectively. Notably, vaginal melanomas showed a NRAS mutation rate of 43%. KIT gene amplification (≥4 copies), as assessed by quantitative real-time PCR, was observed in 19% of cases. KIT expression was associated with KIT mutation status (P < 0.001) and was more common in vulvar than nonvulvar tumors (P = 0.016). Expression of p-ERK and p-AKT was observed in 42% and 59% of tumors, respectively, and occurred irrespective of KIT/NRAS/BRAF mutation status. NRAS mutation was associated with worse overall survival in univariate analysis. Results show that KIT mutations are more common in vulvar melanomas than other types of mucosal melanomas and that both the RAF/MEK/ERK and PI3K/AKT pathways are activated in mucosal melanoma specimens. ©2011 AACR.

  6. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    NASA Technical Reports Server (NTRS)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  7. DEMONSTRATION BULLETIN: HNU-HANBY PCP IMMUNOASSAY TEST KIT - HNU - SYSTEMS, INC.

    EPA Science Inventory

    The HNU-Hanby test kit rapidly analyzes for petroleum hydrocarbons in soil and water samples. The test kit can be used to estimate pentachlorophenol (PCP) concentrations in samples when the carrier solvent is a petroleum hydrocarbon. The test kit estimates PCP concentrations in ...

  8. Kit W-sh Mutation Prevents Cancellous Bone Loss during Calcium Deprivation.

    PubMed

    Lotinun, Sutada; Suwanwela, Jaijam; Poolthong, Suchit; Baron, Roland

    2018-01-01

    Calcium is essential for normal bone growth and development. Inadequate calcium intake increases the risk of osteoporosis and fractures. Kit ligand/c-Kit signaling plays an important role in regulating bone homeostasis. Mice with c-Kit mutations are osteopenic. The present study aimed to investigate whether impairment of or reduction in c-Kit signaling affects bone turnover during calcium deprivation. Three-week-old male WBB6F1/J-Kit W /Kit W-v /J (W/W v ) mice with c-Kit point mutation, Kit W-sh /HNihrJaeBsmJ (W sh /W sh ) mice with an inversion mutation in the regulatory elements upstream of the c-Kit promoter region, and their wild-type controls (WT) were fed either a normal (0.6% calcium) or a low calcium diet (0.02% calcium) for 3 weeks. μCT analysis indicated that both mutants fed normal calcium diet had significantly decreased cortical thickness and cancellous bone volume compared to WT. The low calcium diet resulted in a comparable reduction in cortical bone volume and cortical thickness in the W/W v and W sh /W sh mice, and their corresponding controls. As expected, the low calcium diet induced cancellous bone loss in the W/W v mice. In contrast, W sh /W sh cancellous bone did not respond to this diet. This c-Kit mutation prevented cancellous bone loss by antagonizing the low calcium diet-induced increase in osteoblast and osteoclast numbers in the W sh /W sh mice. Gene expression profiling showed that calcium deficiency increased Osx, Ocn, Alp, type I collagen, c-Fms, M-CSF, and RANKL/OPG mRNA expression in controls; however, the W sh mutation suppressed these effects. Our findings indicate that although calcium restriction increased bone turnover, leading to osteopenia, the decreased c-Kit expression levels in the W sh /W sh mice prevented the low calcium diet-induced increase in cancellous bone turnover and bone loss but not the cortical bone loss.

  9. Data on quantification of signaling pathways activated by KIT and PDGFRA mutants.

    PubMed

    Bahlawane, Christelle; Schmitz, Martine; Letellier, Elisabeth; Arumugam, Karthik; Nicot, Nathalie; Nazarov, Petr V; Haan, Serge

    2016-12-01

    The present data are related to the article entitled "Insights into ligand stimulation effects on gastro-intestinal stromal tumors signaling" (C. Bahlawane, M. Schmitz, E. Letellier, K. Arumugam, N. Nicot, P.V. Nazarov, S. Haan, 2016) [1]. Constitutive and ligand-derived signaling pathways mediated by KIT and PDGFRA mutated proteins found in gastrointestinal stromal tumors (GIST) were compared. Expression of mutant proteins was induced by doxycycline in an isogenic background (Hek293 cells). Kit was identified by FACS at the cell surface and found to be quickly degraded or internalized upon SCF stimulation for both Kit Wild type and Kit mutant counterparts. Investigation of the main activated pathways in GIST unraveled a new feature specific for oncogenic KIT mutants, namely their ability to be further activated by Kit ligand, the stem cell factor (scf). We were also able to identify the MAPK pathway as the most prominent target for a common inhibition of PDGFRA and KIT oncogenic signaling. Western blotting and micro-array analysis were applied to analyze the capacities of the mutant to induce an effective STATs response. Among all Kit mutants, only Kit Ex11 deletion mutant was able to elicit an effective STATs response whereas all PDGFRA were able to do so.

  10. Converting Energy Subsidies to Investments: Scaling-Up Deep Energy Retrofit in Residential Sector of Ukraine

    NASA Astrophysics Data System (ADS)

    Denysenko, Artur

    After collapse of the Soviet Union, Ukraine inherited vast and inefficient infrastructure. Combination of historical lack of transparency, decades without reforms, chronical underinvestment and harmful cross-subsidization resulted in accumulation of energy problems, which possess significant threat to economic prosperity and national security. High energy intensity leads to excessive use of energy and heavy reliance on energy import to meet domestic demand. Energy import, in turn, results in high account balance deficit and heavy burden on the state finances. A residential sector, which accounts for one third of energy consumption and is the highest consumer of natural gas, is particularly challenging to reform. This thesis explores energy consumption of the residential sector of Ukraine. Using energy decomposition method, recent changes in energy use is analyzed. Energy intensity of space heating in the residential sector of Ukraine is compared with selected EU member states with similar climates. Energy efficiency potential is evaluated for whole residential sector in general and for multistory apartment buildings connected to the district heating in particular. Specifically, investments in thermal modernization of multistory residential buildings will result in almost 45TWh, or 3.81 Mtoe, of annual savings. Required investments for deep energy retrofit of multistory buildings is estimated as much as $19 billion in 2015 prices. Experience of energy subsidy reforms as well as lessons from energy retrofit policy from selected countries is analyzed. Policy recommendations to turn energy subsidies into investments in deep energy retrofit of residential sector of Ukraine are suggested. Regional dimension of existing energy subsidies and capital subsidies required for energy retrofit is presented.

  11. ConKit: a python interface to contact predictions.

    PubMed

    Simkovic, Felix; Thomas, Jens M H; Rigden, Daniel J

    2017-07-15

    Recent advances in protein residue contact prediction algorithms have led to the emergence of many new methods and a variety of file formats. We present ConKit , an open source, modular and extensible Python interface which allows facile conversion between formats and provides an interface to analyses of sequence alignments and sets of contact predictions. ConKit is available via the Python Package Index. The documentation can be found at http://www.conkit.org . ConKit is licensed under the BSD 3-Clause. hlfsimko@liverpool.ac.uk or drigden@liverpool.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  12. Emergency medical kit for commercial airlines: an update.

    PubMed

    Thibeault, Claude

    2002-06-01

    As expected, the issue of medical kits for commercial airlines continues to attract attention, especially in light of the recent United States regulation on the subject. As promised in its first recommendation in 1998, the Air Transport Medicine (ATM) Committee has continued to monitor medical kit usage as well as pharmaceutical scientific developments and wishes to propose an update to its 1998 recommendation. Lists of contents are provided for emergency medical kits of two types: 1) those without defibrillator/monitor or monitor; and 2) those with defibrillator/monitor or monitor alone. Follow up and updates on this issue will be an ongoing task of the ATM Committee.

  13. Personalized Thematic Kits

    ERIC Educational Resources Information Center

    Bontrager, Sharon

    2010-01-01

    Teaching Spanish at the K-5 level is a passion of mine, and the author would like to share some of the practical applications that she finds most rewarding and effective. She has found enthusiastic response to the creation of detailed language learning kits that are rooted in storytelling, but expanded to include home-made board games,…

  14. Kit fox population trends at the Naval Petroleum Reserves in California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kato, T.T.; Scrivner, J.H.; Warrick, G.

    The San Joaquin kit fox was listed as an endangered subspecies following passage of the Endangered Species Protection Act of 1966, and further classified as rare under the California Endangered Species Act of 1970. The San Joaquin kit fox occurs on the Naval Petroleum Reserves in California administered by the Department of Energy (DOE). A long term kit fox population monitoring program was initiated as part of DOE's mitigation strategy to comply with the Endangered Species Act. In addition to monitoring kit fox populations, the program includes assessments of kit fox prey density and assessments of predator abundance. The objectivesmore » of this study were to: describe the long term changes in the kit fox population on the Reserves and assess the roles of coyotes and lagomorphs in kit fox population dynamics. When the fox population on NPR-1 declined between 1980 and 1984, it appeared to have been negatively impacted by a declining prey base (lagomorphs) and an increasing coyote population. Declining lagomorph densities may have been a more important factor because as coyote numbers declined between 1985 and 1990, the kit fox population remained stable. The fox population on NPR-2 remained at a higher and more stable level than the population on NPR-1. The factors determining the higher densities and greater stability of the fox population on NPR-2 are unknown.« less

  15. Serials Control and Deselection Projects. SPEC Kit 147.

    ERIC Educational Resources Information Center

    Association of Research Libraries, Washington, DC. Office of Management Studies.

    This Systems and Procedures Exchange Center (SPEC) Kit on serials control and deselection projects provides a timely review of the efforts of research libraries to control the increasing costs of serial subscriptions. This kit contains documents from 13 libraries: University of California at Los Angeles and Riverside; Universities of Florida,…

  16. Increasing benefits of energy assistance programs through oil furnace retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-01

    Four million low income households in the Unites States heat with fuel oil. Those in colder climates are confronting severe hardships. The Fuel Oil Marketing Advisory Committee (FOMAC) of the US Department of Energy (DOE) has documented the desperate nature of this situation, which continues to worsen as prices rise. For FY 1982, the Administration has proposed that HHS administer a four-year block grant to states combining LIEAP with emergency assistance to the needy, and has requested an authorization of $1.875 billion annually for the two combined programs. HHS has taken the position that states should now have the optionmore » of using Low Income Energy Assistance Program (LIEAP) monies for low cost weatherization including furnace retrofits. This report is intended for those who may be involved in making decisions about the nature of future energy assistance programs. The major sections of the report are evaluation of the Phildelphia Pilot Program, economics of an Oil Furnace Retrofit Program, and administrators' considerations. Each section is supported by appendices as listed in the table of contents.« less

  17. Dealing with the increased radon concentration in thermally retrofitted buildings.

    PubMed

    Jiránek, M; Kačmaříková, V

    2014-07-01

    The influence of energy-saving measures on indoor radon concentration has been studied on the basis of a family house made of clinker concrete wall panels containing from 1000 up to 4000 Bq kg(-1) of 226Ra. Thermal retrofitting based on installing external thermal insulation composite system on the building envelope and replacing existing windows by new ones decreased the annual energy need for heating 2.8 times, but also reduced the ventilation rate to values<0.1 h(-1). As a consequence, the 1-y average indoor radon concentration values increased 3.4 times from 337 to 1117 Bq m(-3). The additional risk of lung cancer in the thermally retrofitted house increased to a value that is 125 % higher than before conversion. Methods for dealing with this enhanced risk by increasing the ventilation rate are discussed. Recovery of investments and the energy consequences of increased ventilation are studied in a long-term perspective. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Performance evaluation of a retrofit digital detector-based mammography system.

    PubMed

    Marshall, Nicholas W; van Ongeval, Chantal; Bosmans, Hilde

    2016-02-01

    A retrofit flat panel detector was integrated with a GE DMR+ analog mammography system and characterized using detective quantum efficiency (DQE). Technical system performance was evaluated using the European Guidelines protocol, followed by a limited evaluation of clinical image quality for 20 cases using image quality criteria in the European Guidelines. Optimal anode/filter selections were established using signal difference-to-noise ratio measurements. Only small differences in peak DQE were seen between the three anode/filter settings, with an average value of 0.53. For poly(methyl methacrylate) (PMMA) thicknesses above 60 mm, the Rh/Rh setting was the optimal anode/filter setting. The system required a mean glandular dose of 0.54 mGy at 30 kV Rh/Rh to reach the Acceptable gold thickness limit for 0.1 mm details. Imaging performance of the retrofit unit with the GE DMR+ is notably better than of powder based computed radiography systems and is comparable to current flat panel FFDM systems. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Experimental study on the particulate matter and nitrogenous compounds from diesel engine retrofitted with DOC+CDPF+SCR

    NASA Astrophysics Data System (ADS)

    Zhang, Yunhua; Lou, Diming; Tan, Piqiang; Hu, Zhiyuan

    2018-03-01

    The increasingly stringent emission regulations will mandate the retrofit of after-treatment devices for in-use diesel vehicles, in order to reduce their substantial particulate matter and nitrogen oxides (NOX) emissions. In this paper, a combination of DOC (diesel oxidation catalyst), CDPF (catalytic diesel particulate filter) and SCR (selective catalytic reduction) retrofit for a heavy-duty diesel engine was employed to perform experiment on the engine test bench to evaluate the effects on the particulate matter emissions including particle number (PN), particle mass (PM), particle size distributions and nitrogenous compounds emissions including NOX, nitrogen dioxide (NO2)/NOX, nitrous oxide (N2O) and ammonia (NH3) slip. In addition, the urea injection was also of our concern. The results showed that the DOC+CDPF+SCR retrofit almost had no adverse effect on the engine power and fuel consumption. Under the test loads, the upstream DOC and CDPF reduced the PN and PM by an average of 91.6% and 90.9%, respectively. While the downstream SCR brought about an average decrease of 85% NOX. Both PM and NOX emission factors based on this retrofit were lower than China-Ⅳ limits (ESC), and even lower than China-Ⅴ limits (ESC) at medium and high loads. The DOC and CDPF changed the particle size distributions, leading to the increase in the proportion of accumulation mode particles and the decrease in the percentage of nuclear mode particles. This indicates that the effect of DOC and CDPF on nuclear mode particles was better than that of accumulation mode ones. The upstream DOC could increase the NO2/NOX ratio to 40%, higher NO2/NOX ratio improved the efficiency of CDPF and SCR. Besides, the N2O emission increased by an average of 2.58 times after the retrofit and NH3 slip occurred with the average of 26.7 ppm. The rate of urea injection was roughly equal to 8% of the fuel consumption rate. The DOC+CDPF+SCR retrofit was proved a feasible and effective measurement in terms

  20. Mutational status of EGFR and KIT in thymoma and thymic carcinoma.

    PubMed

    Yoh, Kiyotaka; Nishiwaki, Yutaka; Ishii, Genichiro; Goto, Koichi; Kubota, Kaoru; Ohmatsu, Hironobu; Niho, Seiji; Nagai, Kanji; Saijo, Nagahiro

    2008-12-01

    This study was conducted to evaluate the prevalence of EGFR and KIT mutations in thymomas and thymic carcinomas as a means of exploring the potential for molecularly targeted therapy with tyrosine kinase inhibitors. Genomic DNA was isolated from 41 paraffin-embedded tumor samples obtained from 24 thymomas and 17 thymic carcinomas. EGFR exons 18, 19, and 21, and KIT exons 9, 11, 13, and 17, were analyzed for mutations by PCR and direct sequencing. Protein expression of EGFR and KIT was evaluated immunohistochemically. EGFR mutations were detected in 2 of 20 thymomas, but not in any of the thymic carcinomas. All of the EGFR mutations detected were missense mutations (L858R and G863D) in exon 21. EGFR protein was expressed in 71% of the thymomas and 53% of the thymic carcinomas. The mutational analysis of KIT revealed only a missense mutation (L576P) in exon 11 of one thymic carcinoma. KIT protein was expressed in 88% of the thymic carcinomas and 0% of the thymomas. The results of this study indicate that EGFR and KIT mutations in thymomas and thymic carcinomas are rare, but that many of the tumors express EGFR or KIT protein.

  1. Kit receptor tyrosine kinase dysregulations in feline splenic mast cell tumours.

    PubMed

    Sabattini, S; Barzon, G; Giantin, M; Lopparelli, R M; Dacasto, M; Prata, D; Bettini, G

    2017-09-01

    This study investigated Kit receptor dysregulations (cytoplasmic immunohistochemical expression and/or c-KIT mutations) in cats affected with splenic mast cell tumours. Twenty-two cats were included. Median survival time was 780 days (range: 1-1219). An exclusive splenic involvement was significantly (P = 0.042) associated with longer survival (807 versus 120 days). Eighteen tumours (85.7%) showed Kit cytoplasmic expression (Kit pattern 2, 3). Mutation analysis was successful in 20 cases. Fourteen missense mutations were detected in 13 out of 20 tumours (65%). Eleven (78.6%) were located in exon 8, and three (21.6%) in exon 9. No mutations were detected in exons 11 and 17. Seven mutations corresponded to the same internal tandem duplication in exon 8 (c.1245_1256dup). Although the association between Kit cytoplasmic expression and mutations was significant, immunohistochemistry cannot be considered a surrogate marker for mutation analysis. No correlation was observed between c-Kit mutations and tumour differentiation, mitotic activity or survival. © 2016 John Wiley & Sons Ltd.

  2. Existing Whole-House Solutions Case Study: Cascade Apartments - Deep Energy Multifamily Retrofit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-02-01

    In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington, which resulted in annual energy cost savings of 22%, improved comfort and air quality for residents, and increased durability of the units. This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary Building America research questions: 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings comparemore » with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio of the retrofit package after considering utility window incentives and KCHA capital improvement funding.« less

  3. Private sector village enterprise a new approach to sustainable financing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gay, C.F.

    1997-12-01

    This paper presents an enterprise plan for introducing solar power in a rural market, while providing economic development, and hence the ability of the user to pay for the power source. This plan is based on a product called GEEP - a solar sewing machine conversion kit. This kit can be retrofit onto pedal sewing machines and marketed to village tailors in India, as part of a marketing program which includes increased demand for tailored products which will allow the tailors to be able to finance the conversion kits.

  4. Essential requirement for PP2A inhibition by the oncogenic receptor c-KIT suggests PP2A reactivation as a strategy to treat c-KIT+ cancers

    PubMed Central

    Roberts, Kathryn G.; Smith, Amanda M.; McDougall, Fiona; Carpenter, Helen; Horan, Martin; Neviani, Paolo; Powell, Jason A.; Thomas, Daniel; Guthridge, Mark A.; Perrotti, Danilo; Sim, Alistair T.R.; Ashman, Leonie K.; Verrills, Nicole M.

    2010-01-01

    Oncogenic mutations of the receptor tyrosine kinase c-KIT play an important role in the pathogenesis of gastrointestinal stromal tumors (GIST), systemic mastocytosis, and some acute myeloid leukemias (AML). Whilst juxtamembrane mutations commonly detected in GIST are sensitive to tyrosine kinase inhibitors, the kinase domain mutations frequently encountered in systemic mastocytosis and AML confer resistance and are largely unresponsive to targeted inhibition by the existing agent imatinib. In this study we show that myeloid cells expressing activated c-KIT mutants that are imatinib-sensitive (V560G) or –resistant (D816V) can inhibit the tumor suppressor activity of protein phosphatase 2A (PP2A). This effect was associated with reduced expression of PP2A structural (A) and regulatory subunits (B55α; B56α; B56γ and B56δ). Overexpression of PP2A-Aα in D816V c-KIT cells induced apoptosis and inhibited proliferation. In addition, pharmacological activation of PP2A by FTY720 reduced proliferation, inhibited clonogenic potential and induced apoptosis of mutant c-KIT+ cells, whilst having no effect on WT c-KIT cells or empty vector controls. FTY720 treatment caused dephosphorylation of the D816V c-KIT receptor and its downstream signaling targets pAkt, pSTAT5 and pERK1/2. Additionally, in vivo administration of FTY720 delayed the growth of V560G and D816V c-KIT tumors, inhibited splenic and bone marrow infiltration, and prolonged survival. Our findings show that PP2A inhibition is essential for c-KIT-mediated tumorigenesis, and that reactivating PP2A may offer an attractive strategy to treat drug-resistant c-KIT+ cancers. PMID:20551067

  5. Conditional Deletion of Kit in Melanocytes: White Spotting Phenotype Is Cell Autonomous.

    PubMed

    Aoki, Hitomi; Tomita, Hiroyuki; Hara, Akira; Kunisada, Takahiro

    2015-07-01

    It is well established that cell-intrinsic signaling through the receptor tyrosine kinase KIT is critical for the development of neural crest-derived melanocytes. Nevertheless, it is not entirely clear whether Kit acts exclusively in a melanocyte-autonomous manner or in addition indirectly through other cell types. To address this question in vivo, we generated a targeted allele of Kit that allowed for CRE recombinase-mediated deletion of the transmembrane domain of KIT. Mice carrying one copy of the targeted allele and expressing CRE under the melanoblast/melanocyte-specific tyrosinase promoter exhibited a white spotting phenotype that was even more extensive compared with that found in mice heterozygous for a Kit-null allele. This phenotype is unlikely the result of sequestration of KIT ligand by neighboring cells or by potentially secreted forms of KIT because the spotting phenotype could not be rescued by overexpression of KITL. Likewise, overexpression of endothelin-3 or hepatocyte growth factor was unable to rescue melanocytes in these mice. Although the severity of the observed phenotype remains to be explained, the findings indicate that melanocyte-selective impairment of Kit is sufficient to interfere with normal melanocyte development.

  6. Test/QA Plan for Verification of Microcystin Test Kits

    EPA Science Inventory

    Microcystin test kits are used to quantitatively measure total microcystin in recreational waters. These test kits are based on enzyme-linked immunosorbent assays (ELISA) with antibodies that bind specifically to microcystins or phosphate activity inhibition where the phosphatas...

  7. Traffic noise analysis protocol : for new highway construction, reconstruction and retrofit barrier projects.

    DOT National Transportation Integrated Search

    2006-08-01

    The purpose of this Traffic Noise Analysis Protocol for New Highway : Construction, Reconstruction, and Retrofit Barrier Projects (Protocol) is : to present California Department of Transportation (Caltrans) policies and : procedures for applying 23 ...

  8. Projectable Basic Electronics Kit.

    ERIC Educational Resources Information Center

    H'ng, John; And Others

    1982-01-01

    Outlines advantages derived from constructing and using a Projectable Basic Electronics Kit and provides: (1) list of components; (2) diagrams of 10 finished components (resistor; capacitor; diode; switch; bulb; transistor; meter; variable capacitor; coil; connecting terminal); and (3) diode and transistor activities. (JN)

  9. [Development of ELISA-kit of quantitative analysis for Zearalenone].

    PubMed

    Wang, Yu-ping; Ji, Rong; Jiang, Tao; Kang, Wei-jun

    2006-03-01

    To develope a rapid, sensitive, quantitative ELISA-kit for Zearalenone and determine zearalenone in cereals. On the base of monoclonal antibodies against ZEN, apply indirect ELISA to study the performance parameter of the kit. The limited concentration of detection of the ELISA-kit was 1ng/ml, linear range was 1-200 ng/ml, the linear equation was Y = 0.99 - 0.40 x (R2 = 0.99). The inhibition concentration of 50% against ZEN was 16.3 ng/ml. The average recovery rate of spiked corn and wheat was 96.5% and 95.5%, respectively, the coefficient of variant was 13.2% and 10.9%, respectively. The kit can be stored at 4 degrees C over 6 months. The cross reaction rate with the other mycotoxins was less than 1%, and coefficient of variant within-laboratory and between-laboratory was less than 15% and less than 20%, respectively. Detecting the VICAM sample with ELISA method and HPLC method, the results were within the range of the sample, and there was no statistic difference between the two methods. This ELISA-kit was quick, sensitive, stable and specific and can be used to determine ZEN in cereals.

  10. Elevated expression of the proto-oncogene c-kit in patients with mastocytosis.

    PubMed

    Nagata, H; Worobec, A S; Semere, T; Metcalfe, D D

    1998-02-01

    The stem cell factor (SCF)c-kit receptor interaction plays a critical role in the development and survival of mast cells. Several studies have also associated c-kit receptor mutations with the human diseases, mastocytosis and piebaldism. Overexpression of c-kit has been reported to be associated with myeloproliferative disorders and myelodysplastic syndromes. Using peripheral blood mononuclear cells (PBMCs) from 11 patients with indolent mastocytosis (category I), mastocytosis with an associated hematologic disorder (category II), or aggressive mastocytosis (category III); a patient with CMML unassociated with mastocytosis, and PBMCs from 13 normal subjects, we examined the level of expression of c-kit mRNA along with other c-kit isoforms to determine if overexpression of the c-kit receptor was associated with mastocytosis. Using quantitative competitive PCR, c-kit mRNA levels on average were found to be statistically elevated in the five patients with mastocytosis with an associated hematologic disorder and in the patient with aggressive mastocytosis as compared with controls, but not elevated in patients with indolent mastocytosis. The relative mRNA expression for the two c-kit isoforms was not significantly different in the mastocytosis patients compared with controls. This demonstration of the overexpression of c-kit mRNA in mastocytosis, and particularly those patients with clinical evidence of myelodysplastic syndrome, adds evidence to support the conclusion that mastocytosis, at least in some patients, is a feature of myelodysplasia; and suggests that determination of c-kit mRNA expression in PBMCs may provide an additional approach to assessing prognosis.

  11. c-kit expression profile and regulatory factors during spermatogonial stem cell differentiation

    PubMed Central

    2013-01-01

    Background It has been proven that c-kit is crucial for proliferation, migration, survival and maturation of spermatogenic cells. A periodic expression of c-kit is observed from primordial germ cells (PGCs) to spermatogenetic stem cells (SSCs), However, the expression profile of c-kit during the entire spermatogenesis process is still unclear. This study aims to reveal and compare c-kit expression profiles in the SSCs before and after the anticipated differentiation, as well as to examine its relationship with retinoic acid (RA) stimulation. Results We have found that there are more than 4 transcripts of c-kit expressed in the cell lines and in the testes. The transcripts can be divided into short and long categories. The long transcripts include the full-length canonical c-kit transcript and the 3′ end short transcript. Short transcripts include the 3.4 kb short transcript and several truncated transcripts (1.9-3.2 kb). In addition, the 3.4 kb transcript (starting from intron 9 and covering exons 10 ~ 21) is discovered to be specifically expressed in the spermatogonia. The extracellular domain of Kit is obtained in the spermatogonia stage, but the intracellular domain (50 kDa) is constantly expressed in both SSCs and spermatogonia. The c-kit expression profiles in the testis and the spermatogonial stem cell lines vary after RA stimulation. The wave-like changes of the quantitative expression pattern of c-kit (increase initially and decrease afterwards) during the induction process are similar to that of the in vivo male germ cell development process. Conclusions There are dynamic transcription and translation changes of c-kit before and after SSCs’ anticipated differentiation and most importantly, RA is a significant upstream regulatory factor for c-kit expression. PMID:24161026

  12. The Three R's of Utility Savings: Rate Reduction, Rebates and Retrofit.

    ERIC Educational Resources Information Center

    Petiunas, Raymond V.

    1993-01-01

    An effective way to increase electricity energy savings for school districts is to integrate rate case participation (rate reduction) with conservation and load-management efforts (rebates) and retrofit operations, to obtain a total energy cost reduction package. Describes how a Pennsylvania consortium of school districts saved its member…

  13. Single-cell analysis of the fate of c-kit-positive bone marrow cells

    NASA Astrophysics Data System (ADS)

    Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D.; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa

    2017-10-01

    The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.

  14. Single-cell analysis of the fate of c-kit-positive bone marrow cells.

    PubMed

    Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa

    2017-01-01

    The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.

  15. SOLVENT-BASED TO WATERBASED ADHESIVE-COATED SUBSTRATE RETROFIT - VOLUME I: COMPARATIVE ANALYSIS

    EPA Science Inventory

    This volume represents the analysis of case study facilities' experience with waterbased adhesive use and retrofit requirements. (NOTE: The coated and laminated substrate manufacturing industry was selected as part of NRMRL'S support of the 33/50 Program because of its significan...

  16. The usefulness of c-Kit in the immunohistochemical assessment of melanocytic lesions

    PubMed Central

    Pilloni, L.; Bianco, P.; Difelice, E.; Cabras, S.; Castellanos, M.E.; Atzori, L.; Ferreli, C.; Mulas, P.; Nemolato, S.; Faa, G.

    2011-01-01

    C-Kit (CD117), the receptor for the stem cell factor, a growth factor for melanocyte migration and proliferation, has shown differential immunostaining in various benign and malignant melanocytic lesions. The purpose of this study is to compare c-Kit immunostaining in benign nevi and in primary and metastatic malignant melanomas, to determine whether c-Kit can aid in the differential diagnosis of these lesions. c-Kit immunostaining was performed in 60 cases of pigmented lesions, including 39 benign nevi (5 blue nevi, 5 intra-dermal nevi, 3 junctional nevi, 15 cases of primary compound nevus, 11 cases of Spitz nevus), 18 cases of primary malignant melanoma and 3 cases of metastatic melanoma. The vast majority of nevi and melanomas examined in this study were positive for c-Kit, with minimal differences between benign and malignant lesions. C-Kit cytoplasmatic immunoreactivity in the intraepidermal proliferating nevus cells, was detected in benign pigmented lesions as well as in malignant melanoma, increasing with the age of patients (P=0.007) in both groups. The patient’s age at presentation appeared to be the variable able to cluster benign and malignant pigmented lesions. The percentage of c-Kit positive intraepidermal nevus cells was better associated with age despite other variables (P=0.014). The intensity and percentage of c-Kit positivity in the proliferating nevus cells in the dermis was significantly increased in malignant melanocytic lesions (P=0.015 and P=0.008) compared to benign lesions (compound melanocytic nevi, Spitz nevi, intradermal nevi, blue nevi). Immunostaning for c-Kit in metastatic melanomas was negative. Interestingly in two cases of melanoma occurring on a pre-existent nevus, the melanoma tumor cells showed strong cytoplasmatic and membranous positivity for c-kit, in contrast with the absence of any immunoreactivity in pre-existent intradermal nevus cells. C-Kit does not appear to be a strong immunohistochemical marker for distinguishing

  17. Regional hospital improves efficiency with co-generation retrofit.

    PubMed

    Knutson, D; Anderson, L

    1999-11-01

    Feasibility analysis of the co-generation retrofit of the Red Deer Regional Hospital pointed to a reasonable payback of capital cost and increased efficiency in operation of the facility. Budget restrictions nearly stopped the project from proceeding. Innovative construction procedures proposed by the Facility Management Group, in particular, Mr Keith Metcalfe, Director of Maintenance, allowed a worthwhile project to reach successful completion. We feel that this model can perhaps be used by similar facilities in the future to achieve their energy efficiency goals.

  18. The Next Step Toward Widespread Residential Deep Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McIlvaine, J.; Martin, E.; Saunders, S.

    The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

  19. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Conlin, Francis; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  20. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less