Sample records for occluded previous tips

  1. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  2. 21 CFR 870.1370 - Catheter tip occluder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip occluder. 870.1370 Section 870.1370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1370 Catheter tip occluder...

  3. Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp; Guenther, Rolf W., E-mail: guenther@rad.rwth-aachen.de; Isfort, Peter, E-mail: isfort@hia.rwth-aachen.de

    Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of themore » TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.« less

  4. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu; Elliott, Eric D., E-mail: eric.elliott@osumc.edu; Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  5. Detection scheme for a partially occluded pedestrian based on occluded depth in lidar-radar sensor fusion

    NASA Astrophysics Data System (ADS)

    Kwon, Seong Kyung; Hyun, Eugin; Lee, Jin-Hee; Lee, Jonghun; Son, Sang Hyuk

    2017-11-01

    Object detections are critical technologies for the safety of pedestrians and drivers in autonomous vehicles. Above all, occluded pedestrian detection is still a challenging topic. We propose a new detection scheme for occluded pedestrian detection by means of lidar-radar sensor fusion. In the proposed method, the lidar and radar regions of interest (RoIs) have been selected based on the respective sensor measurement. Occluded depth is a new means to determine whether an occluded target exists or not. The occluded depth is a region projected out by expanding the longitudinal distance with maintaining the angle formed by the outermost two end points of the lidar RoI. The occlusion RoI is the overlapped region made by superimposing the radar RoI and the occluded depth. The object within the occlusion RoI is detected by the radar measurement information and the occluded object is estimated as a pedestrian based on human Doppler distribution. Additionally, various experiments are performed in detecting a partially occluded pedestrian in outdoor as well as indoor environments. According to experimental results, the proposed sensor fusion scheme has much better detection performance compared to the case without our proposed method.

  6. Management of Bleeding Duodenal Varices with Combined TIPS Decompression and Trans-TIPS Transvenous Obliteration Utilizing 3% Sodium Tetradecyl Sulfate Foam Sclerosis.

    PubMed

    Saad, Wael E; Lippert, Allison; Schwaner, Sandra; Al-Osaimi, Abdullah; Sabri, Saher; Saad, Nael

    2014-01-01

    Endoscopic experience in the management of duodenal varices (DVs) is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS) or by transvenous obliteration is unresolved. In the literature, the 6-12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. This is a retrospective study (case series) of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013). TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis) from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs) and clinical outcomes (rebleeding rate and survival) were evaluated. Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally) receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days). After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6-50 months). Coils and/or metallic vascular plugs were used to augment

  7. Catching what we can't see: manual interception of occluded fly-ball trajectories.

    PubMed

    Bosco, Gianfranco; Delle Monache, Sergio; Lacquaniti, Francesco

    2012-01-01

    Control of interceptive actions may involve fine interplay between feedback-based and predictive mechanisms. These processes rely heavily on target motion information available when the target is visible. However, short-term visual memory signals as well as implicit knowledge about the environment may also contribute to elaborate a predictive representation of the target trajectory, especially when visual feedback is partially unavailable because other objects occlude the visual target. To determine how different processes and information sources are integrated in the control of the interceptive action, we manipulated a computer-generated visual environment representing a baseball game. Twenty-four subjects intercepted fly-ball trajectories by moving a mouse cursor and by indicating the interception with a button press. In two separate sessions, fly-ball trajectories were either fully visible or occluded for 750, 1000 or 1250 ms before ball landing. Natural ball motion was perturbed during the descending trajectory with effects of either weightlessness (0 g) or increased gravity (2 g) at times such that, for occluded trajectories, 500 ms of perturbed motion were visible before ball disappearance. To examine the contribution of previous visual experience with the perturbed trajectories to the interception of invisible targets, the order of visible and occluded sessions was permuted among subjects. Under these experimental conditions, we showed that, with fully visible targets, subjects combined servo-control and predictive strategies. Instead, when intercepting occluded targets, subjects relied mostly on predictive mechanisms based, however, on different type of information depending on previous visual experience. In fact, subjects without prior experience of the perturbed trajectories showed interceptive errors consistent with predictive estimates of the ball trajectory based on a-priori knowledge of gravity. Conversely, the interceptive responses of subjects

  8. Management of Bleeding Duodenal Varices with Combined TIPS Decompression and Trans-TIPS Transvenous Obliteration Utilizing 3% Sodium Tetradecyl Sulfate Foam Sclerosis

    PubMed Central

    Saad, Wael E; Lippert, Allison; Schwaner, Sandra; Al-Osaimi, Abdullah; Sabri, Saher; Saad, Nael

    2014-01-01

    Objectives: Endoscopic experience in the management of duodenal varices (DVs) is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS) or by transvenous obliteration is unresolved. In the literature, the 6–12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. Materials and Methods: This is a retrospective study (case series) of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013). TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis) from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs) and clinical outcomes (rebleeding rate and survival) were evaluated. Results: Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally) receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days). After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6–50 months). Coils and

  9. Catching What We Can't See: Manual Interception of Occluded Fly-Ball Trajectories

    PubMed Central

    Bosco, Gianfranco; Delle Monache, Sergio; Lacquaniti, Francesco

    2012-01-01

    Control of interceptive actions may involve fine interplay between feedback-based and predictive mechanisms. These processes rely heavily on target motion information available when the target is visible. However, short-term visual memory signals as well as implicit knowledge about the environment may also contribute to elaborate a predictive representation of the target trajectory, especially when visual feedback is partially unavailable because other objects occlude the visual target. To determine how different processes and information sources are integrated in the control of the interceptive action, we manipulated a computer-generated visual environment representing a baseball game. Twenty-four subjects intercepted fly-ball trajectories by moving a mouse cursor and by indicating the interception with a button press. In two separate sessions, fly-ball trajectories were either fully visible or occluded for 750, 1000 or 1250 ms before ball landing. Natural ball motion was perturbed during the descending trajectory with effects of either weightlessness (0 g) or increased gravity (2 g) at times such that, for occluded trajectories, 500 ms of perturbed motion were visible before ball disappearance. To examine the contribution of previous visual experience with the perturbed trajectories to the interception of invisible targets, the order of visible and occluded sessions was permuted among subjects. Under these experimental conditions, we showed that, with fully visible targets, subjects combined servo-control and predictive strategies. Instead, when intercepting occluded targets, subjects relied mostly on predictive mechanisms based, however, on different type of information depending on previous visual experience. In fact, subjects without prior experience of the perturbed trajectories showed interceptive errors consistent with predictive estimates of the ball trajectory based on a-priori knowledge of gravity. Conversely, the interceptive responses of subjects

  10. Sub-10-micrometer toughening and crack tip toughness of dental enamel.

    PubMed

    Ang, Siang Fung; Schulz, Anja; Pacher Fernandes, Rodrigo; Schneider, Gerold A

    2011-04-01

    In previous studies, enamel showed indications to occlude small cracks in-vivo and exhibited R-curve behaviors for bigger cracks ex-vivo. This study quantifies the crack tip's toughness (K(I0),K(III0)), the crack's closure stress and the cohesive zone size at the crack tip of enamel and investigates the toughening mechanisms near the crack tip down to the length scale of a single enamel crystallite. The crack-opening-displacement (COD) profile of cracks induced by Vickers indents on mature bovine enamel was studied using atomic force microscopy (AFM). The mode I crack tip toughness K(I0) of cracks along enamel rod boundaries and across enamel rods exhibit a similar range of values: K(I0,Ir)=0.5-1.6MPa m(0.5) (based on Irwin's 'near-field' solution) and K(I0,cz)=0.8-1.5MPa m(0.5) (based on the cohesive zone solution of the Dugdale-Muskhelishvili (DM) crack model). The mode III crack tip toughness K(III0,Ir) was computed as 0.02-0.15MPa m(0.5). The crack-closure stress at the crack tip was computed as 163-770 MPa with a cohesive zone length and width 1.6-10.1μm and 24-44 nm utilizing the cohesive zone solution. Toughening elements were observed under AFM and SEM: crack bridging due to protein ligament and hydroxyapatite fibres (micro- and nanometer scale) as well as microcracks were identified. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  11. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Technique and Intraprocedural Imaging

    PubMed Central

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    Balloon-occluded retrograde transvenous obliteration (BRTO) is an endovascular technique used as a therapeutic adjunct or alternative to transjugular intrahepatic shunts (TIPS) in the management of gastric varices. Occlusion balloons are strategically placed to modulate flow within the gastrorenal or gastrocaval shunt to allow stagnation of the sclerosant material within the gastric varix. The approach and complexity of the procedure depends on the anatomic classification of inflow and outflow veins of the varix. Ethanolamine oleate has been described as the main sclerosant used in this procedure. Recently, foam sclerosants have gained popularity as alternative embolization agents, which provide the advantage of better variceal wall contact and potentially less dose of sclerosant. PMID:22942548

  12. Single-Session Percutaneous Endovascular Mesocaval Shunt Creation and Balloon-Occluded Retrograde Transvenous Obliteration for the Treatment of Gastric Varices.

    PubMed

    Srinivasa, Ravi Nara; Majdalany, Bill S; Chick, Jeffrey Forris Beecham; Meadows, J Matthew; Fenlon, Jordan Bruce; Brewerton, Charles; Saad, Wael E

    2018-01-01

    In the setting of portal hypertension, the body responds by creating portosystemic venous shunts, which may lead to the development of varices. Endoscopic treatment of these varices is often warranted to prevent catastrophic bleeding. During the course of variceal treatment, 1 or more portosystemic shunts may be sacrificed, which may acutely exacerbate portal hypertension and reduce systemic venous return. This report describes percutaneous creation of a mesocaval shunt and balloon-occluded retrograde transvenous obliteration (BRTO) in a patient with cavernous transformation of the portal vein. The patient had previously undergone an unsuccessful attempt at transjugular intrahepatic portosystemic shunt (TIPS) creation with postoperative bleeding requiring splenectomy. As TIPS was not feasible, creation of a percutaneous mesocaval shunt provided an alternate pathway for portosystemic decompression, facilitating safe treatment of gastric varices with BRTO via a gastrorenal shunt. These procedures were performed simultaneously to reduce the risk of variceal bleeding from acute changes in portal venous pressures and redirect blood flow through the shunt to maintain patency. This is the first reported case of combined mesocaval shunt placement and BRTO in a single session. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Time course of spatial and feature selective attention for partly-occluded objects.

    PubMed

    Kasai, Tetsuko; Takeya, Ryuji

    2012-07-01

    Attention selects objects/groups as the most fundamental units, and this may be achieved by an attention-spreading mechanism. Previous event-related potential (ERP) studies have found that attention-spreading is reflected by a decrease in the N1 spatial attention effect. The present study tested whether the electrophysiological attention effect is associated with the perception of object unity or amodal completion through the use of partly-occluded objects. ERPs were recorded in 14 participants who were required to pay attention to their left or right visual field and to press a button for a target shape in the attended field. Bilateral stimuli were presented rapidly, and were separated, connected, or connected behind an occluder. Behavioral performance in the connected and occluded conditions was worse than that in the separated condition, indicating that attention spread over perceptual object representations after amodal completion. Consistently, the late N1 spatial attention effect (180-220 ms post-stimulus) and the early phase (230-280 ms) of feature selection effects (target N2) at contralateral sites decreased, equally for the occluded and connected conditions, while the attention effect in the early N1 latency (140-180 ms) shifted most positively for the occluded condition. These results suggest that perceptual organization processes for object recognition transiently modulate spatial and feature selection processes in the visual cortex. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Recanalisation of Chronically Occluded Remote Superficial Femoral Artery Endarterectomy Through Angioplasty for Limb Salvage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Husainy, Mohammad Ali, E-mail: m.husainy@nhs.net; Slim, Hani; Rashid, Hisham

    2017-02-15

    We report a novel application of balloon angioplasty to recanalise a chronically occluded remote endarterectomy superficial femoral artery. This patient previously had two occluded surgical bypass grafts in an attempt to revascularise the limb and presented with critical limb ischaemia and necrotic foot ulcerations. Following the angioplasty, the patient showed significant improvement in rest pain and healing of the ulcerations. This technique may be useful for limb salvage in patients where surgical options have been exhausted.

  15. Balloon-Occluded Retrograde Transvenous Obliteration of Gastric Varices: Concept, Basic Techniques, and Outcomes

    PubMed Central

    Saad, Wael E. A.

    2012-01-01

    Patients with gastric variceal bleeding require a multidisciplinary team approach including hepatologists, endoscopists, diagnostic radiologists, and interventional radiologists. Upper gastrointestinal endoscopy is the first-line diagnostic and management tool for bleeding gastric varices, as it is in all upper gastrointestinal bleeding scenarios. In the United States when endoscopy fails to control gastric variceal bleeding, a transjugular intrahepatic portosystemic shunt (TIPS) traditionally is performed along the classic teachings of decompressing the portal circulation. However, TIPS has not shown the same effectiveness in controlling gastric variceal bleeding that it has with esophageal variceal bleeding. For the past 2 decades, the balloon-occluded retrograde transvenous obliteration (BRTO) procedure has become common practice in Asia for the management of gastric varices. BRTO is gaining popularity in the United States. It has been shown to be effective in controlling gastric variceal bleeding with low rebleed rates. BRTO has many advantages over TIPS in that it is less invasive and can be performed on patients with poor hepatic reserve and those with encephalopathy (and may even improve both). However, its by-product is occlusion of a spontaneous hepatofugal (TIPS equivalent) shunt, and thus it is contradictory to the traditional American doctrine of portal decompression. Indeed, BRTO causes an increase in portal hypertension, with potential aggravation of esophageal varices and ascites. This article discusses the concept, technique, and outcomes of BRTO within the broader management of gastric varices. PMID:23729982

  16. Decoding information about dynamically occluded objects in visual cortex

    PubMed Central

    Erlikhman, Gennady; Caplovitz, Gideon P.

    2016-01-01

    During dynamic occlusion, an object passes behind an occluding surface and then later reappears. Even when completely occluded from view, such objects are experienced as continuing to exist or persist behind the occluder, even though they are no longer visible. The contents and neural basis of this persistent representation remain poorly understood. Questions remain as to whether there is information maintained about the object itself (i.e. its shape or identity) or, non-object-specific information such as its position or velocity as it is tracked behind an occluder as well as which areas of visual cortex represent such information. Recent studies have found that early visual cortex is activated by “invisible” objects during visual imagery and by unstimulated regions along the path of apparent motion, suggesting that some properties of dynamically occluded objects may also be neurally represented in early visual cortex. We applied functional magnetic resonance imaging in human subjects to examine the representation of information within visual cortex during dynamic occlusion. For gradually occluded, but not for instantly disappearing objects, there was an increase in activity in early visual cortex (V1, V2, and V3). This activity was spatially-specific, corresponding to the occluded location in the visual field. However, the activity did not encode enough information about object identity to discriminate between different kinds of occluded objects (circles vs. stars) using MVPA. In contrast, object identity could be decoded in spatially-specific subregions of higher-order, topographically organized areas such as ventral, lateral, and temporal occipital areas (VO, LO, and TO) as well as the functionally defined LOC and hMT+. These results suggest that early visual cortex may represent the dynamically occluded object’s position or motion path, while later visual areas represent object-specific information. PMID:27663987

  17. AMPLATZER versus Figulla occluder for transcatheter patent foramen ovale closure.

    PubMed

    Trabattoni, Daniela; Gaspardone, Achille; Sgueglia, Gregory A; Fabbiocchi, Franco; Gioffrè, Gaetano; Montorsi, Piero; Calligaris, Giuseppe; Iamele, Maria; De Santis, Antonella; Bartorelli, Antonio L

    2017-04-20

    The aim of this observational study was to compare acute and 12-month results of percutaneous closure of patent foramen ovale (PFO) with two occluder devices. Between June 2007 and October 2014, 406 consecutive patients (48.1±13.3 years, 243 women) underwent percutaneous PFO closure with either the AMPLATZER (n=179) or the Figulla (n=227) device after a stroke or a transient ischaemic attack ascribed to the PFO. A right-to-left shunt grade >1 was previously detected in all patients and atrial septal aneurysm was present in 111 (27.5%) patients. Patients were followed up with a contrast transthoracic echocardiogram and clinically at 24 hours, six months, and 12 months after the procedure. A high procedural success was observed in both groups. Despite a trend towards a higher incidence of acute residual shunt immediately after device deployment among Figulla occluder patients, a residual grade ≥2 right-to-left shunt was observed in 4.5% of patients, independently of the device used for PFO closure. The only difference reported after Figulla device implantation was a lower rate of supraventricular arrhythmias (9% vs. 17%, p=0.02). According to this two-centre study, PFO closure appears safe and effective with the Figulla occluder as well as with the AMPLATZER device.

  18. Subintimal Recanalization of Occluded Stents: The Substent Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diamantopoulos, Athanasios, E-mail: adiamant@upatras.gr; Katsanos, Konstantinos; Spiliopoulos, Stavros

    2013-08-01

    PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end pointsmore » included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan-Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 {+-} 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 {+-} 90.78 mm. The mean occluded stented segment length was 90.21 {+-} 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year's follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI

  19. DNA unwinding by ring-shaped T4 helicase gp41 is hindered by tension on the occluded strand.

    PubMed

    Ribeck, Noah; Saleh, Omar A

    2013-01-01

    The replicative helicase for bacteriophage T4 is gp41, which is a ring-shaped hexameric motor protein that achieves unwinding of dsDNA by translocating along one strand of ssDNA while forcing the opposite strand to the outside of the ring. While much study has been dedicated to the mechanism of binding and translocation along the ssDNA strand encircled by ring-shaped helicases, relatively little is known about the nature of the interaction with the opposite, 'occluded' strand. Here, we investigate the interplay between the bacteriophage T4 helicase gp41 and the ss/dsDNA fork by measuring, at the single-molecule level, DNA unwinding events on stretched DNA tethers in multiple geometries. We find that gp41 activity is significantly dependent on the geometry and tension of the occluded strand, suggesting an interaction between gp41 and the occluded strand that stimulates the helicase. However, the geometry dependence of gp41 activity is the opposite of that found previously for the E. coli hexameric helicase DnaB. Namely, tension applied between the occluded strand and dsDNA stem inhibits unwinding activity by gp41, while tension pulling apart the two ssDNA tails does not hinder its activity. This implies a distinct variation in helicase-occluded strand interactions among superfamily IV helicases, and we propose a speculative model for this interaction that is consistent with both the data presented here on gp41 and the data that had been previously reported for DnaB.

  20. Efficacy of a Creon delayed-release pancreatic enzyme protocol for clearing occluded enteral feeding tubes.

    PubMed

    Stumpf, Janice L; Kurian, Rebecca M; Vuong, Jennifer; Dang, Kimberlyn; Kraft, Michael D

    2014-04-01

    Alkalinized Viokase pancreatic enzyme tablets restored patency to 71.9% of occluded Dobhoff tubes in a prospective study. After removal of Viokase tablets from the US market, the hospital protocol for unclogging enteral feeding tubes was adapted to use Creon pancreatic enzyme delayed-release capsules, despite the lack of published data. To evaluate the effectiveness of a Creon-based protocol to clear occluded enteral feeding tubes. This retrospective study included all adult and pediatric patients seen in the emergency department or in an inpatient setting who received Creon 12 000 units lipase delayed-release capsule dissolved in a solution of sodium bicarbonate 650 mg and sterile water for clearing occluded enteral feeding tubes between May 1 and November 30, 2010. The Creon protocol was deemed effective if tube clearance was documented in the medical record or if enteral feedings were resumed with no note regarding tube replacement. Alkalinized Creon delayed-release capsules were administered to 83 patients with a total of 118 clogged tubes. Three poorly documented cases and 5 tubes with mechanical clogs were excluded from data analysis. Patency was restored to 53 of 110 (48.2%) occluded tubes. More than 1 treatment course was attempted in 5 cases, with success in 3. An alkalinized Creon pancreatic enzyme protocol was effective in clearing approximately half of the occluded enteral feeding tubes in this retrospective study, an efficacy rate much less than that previously reported in the literature with a Viokase-based protocol.

  1. Transcatheter closure of ventricular septal defect with Occlutech Duct Occluder.

    PubMed

    Atik-Ugan, Sezen; Saltik, Irfan Levent

    2018-04-01

    Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.

  2. Computational evaluation of aortic occlusion and the proposal of a novel, improved occluder: Constrained endo-aortic balloon occlusion.

    PubMed

    de Vaal, M H; Gee, M W; Stock, U A; Wall, W A

    2016-12-01

    Because aortic occlusion is arguably one of the most dangerous aortic manipulation maneuvers during cardiac surgery in terms of perioperative ischemic neurological injury, the purpose of this investigation is to assess the structural mechanical impact resulting from the use of existing and newly proposed occluders. Existing (clinically used) occluders considered include different cross-clamps (CCs) and endo-aortic balloon occlusion (EABO). A novel occluder is also introduced, namely, constrained EABO (CEABO), which consists of applying a constrainer externally around the aorta when performing EABO. Computational solid mechanics are employed to investigate each occluder according to a comprehensive list of functional requirements. The potential of a state of occlusion is also considered for the first time. Three different constrainer designs are evaluated for CEABO. Although the CCs were responsible for the highest strains, largest deformation, and most inefficient increase of the occlusion potential, it remains the most stable, simplest, and cheapest occluder. The different CC hinge geometries resulted in poorer performance of CC used for minimally invasive procedures than conventional ones. CEABO with a profiled constrainer successfully addresses the EABO shortcomings of safety, stability, and positioning accuracy, while maintaining its complexities of operation (disadvantage) and yielding additional functionalities (advantage). Moreover, CEABO is able to achieve the previously unattainable potential to provide a clinically determinable state of occlusion. CEABO offers an attractive alternative to the shortcomings of existing occluders, with its design rooted in achieving the highest patient safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Hemolysis induced by PMIVSD occluder.

    PubMed

    Rao, D Sheshagiri; Barik, Ramachandra; Siva Prasad, Akula

    2016-09-01

    Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD) is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  4. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    PubMed

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  5. Vascular occlusion with a balloon-expandable stent occluder.

    PubMed

    Moss, J G; Laborde, J C; Clem, M C; Rivera, F J; Encarnacion, C E; Meyer, K B; Palmaz, J C

    1994-05-01

    To evaluate the effectiveness of a new vascular occlusion device. The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. This new occlusive device offers immediate vascular occlusion with excellent stability.

  6. Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder.

    PubMed

    García-Montes, José A; Camacho-Castro, Anahí; Sandoval-Jones, Juan P; Buendía-Hernández, Alfonso; Calderón-Colmenero, Juan; Patiño-Bahena, Emilia; Zabal, Carlos

    2015-03-01

    Percutaneous closure of patent ductus arteriosus has become the treatment of choice in many centres. In patients with large ducts and pulmonary hypertension, transcatheter closure has been achieved with success using the Amplatzer Duct Occluder or even the Amplatzer Muscular Ventricular Septal Defect Occluder. We present a series of 17 patients with large and hypertensive ductus arteriosus who were treated with an Amplatzer Septal Occluder. The group had 11 female patients (64.7%) and a mean age of 18.6±12.1 years. The haemodynamic and anatomical data are as follows: pulmonary artery systolic pressure 71.3±31.8 mmHg, pulmonary to systemic flow ratio 3.14±1.36, ductal diameter at the pulmonary end 12.5±3.8 mm, and at the aortic end 20.2±7.7 mm; 14 cases (82.3%) had type A ducts. In 11 patients, we began the procedure using a different device - six with duct occluder and five with ventricular septal occluder - and it was changed because of device embolisation in six (35.3%). All septal occluders were delivered successfully. Residual shunt was moderate in six patients (35.3%), mild in eight (47%), trivial in two (11.8%), and no shunt in one (5.9%). Pulmonary systolic pressure decreased to 48.9±10.8 mmHg after occlusion (p=0.0015). Follow-up in 15 patients (88.2%) for 28.4±14.4 months showed complete closure in all cases but one, and continuous decrease of the pulmonary systolic pressure to 31.4±10.5 mmHg. No complications at follow-up have been reported. The Amplatzer Septal Occluder is a good alternative to percutaneously treat large and hypertensive ductus arteriosus.

  7. Comparison of Factors Associated With Occludable Angle Between American Caucasians and Ethnic Chinese

    PubMed Central

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-01-01

    Purpose. To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. Methods. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40–80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. Results. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Conclusions. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese. PMID:24168992

  8. A retrospective comparative study of tunneled haemodialysis catheters inserted through occluded or collateral veins versus conventional methods.

    PubMed

    Powell, Steven; Chan, Tze Yuan; Bhat, Rammohan; Lam, Kimberly; Narlawar, Ranjeet S; Cullen, Nicola; Littler, Peter

    2010-08-01

    Tunneled hemodialysis catheters become essential in dialysis access when there is no possibility of using a functioning arteriovenous fistula. Collateral or occluded veins visible on ultrasound are used for puncture and passage of catheters into the central venous system. Chronically occluded veins are crossed with guidewires to allow dilatation and subsequent passage of hemodialysis catheters. We performed a retrospective analysis of patient demographics, comorbidities, procedural complications, functional survival, performance, and history of previous vascular access. The study group was compared with two control groups in which dialysis catheters were inserted either by radiologists in the interventional suite or by clinicians on the wards. Nineteen patients from the study group were compared with same number of patients in both control groups. The mean age of the study group was higher compared with the control groups. There was no significant difference in mean functional survival, infection rates, dialysis pump speeds in the first 2 weeks, and procedural complications between the study group and the controls. The study group had a significantly higher number of previous vascular access interventions, longer dialysis careers, and more comorbidities. Tunneled dialysis catheter placement by way of collateral or occluded veins appears safe and effective. These techniques give the operator further options when faced with patients possessing challenging vascular access. Indeed, there may be a case for preferential use of these veins to keep patent central veins in reserve.

  9. Arteriography of the left internal mammary artery graft utilizing a balloon-tipped floatation catheter: an alternative approach.

    PubMed

    Sharifi, M; Lauer, J; Pompili, V J; Dillon, J C

    1999-11-01

    In this report, we describe an alternative method to the conventional arteriographic techniques of the left internal mammary artery (LIMA) graft using a balloon-tipped floatation catheter placed within the left subclavian artery. The floatation catheter will serve as both an occluder of the subclavian artery as well as a port for contrast injection. It may be effectively employed in the rare instances where direct cannulation of the LIMA graft is not possible.

  10. Phonation Threshold Pressure Measurement with a Semi-Occluded Vocal Tract

    ERIC Educational Resources Information Center

    Titze, Ingo R.

    2009-01-01

    Purpose: The purpose of this article was to determine if a semi-occluded vocal tract could be used to measure phonation threshold pressure. This is in contrast to the shutter technique, where an alternation between a fully occluded tract and an unoccluded tract is used. Method: Five male and 5 female volunteers phonated through a thin straw held…

  11. Recent development of transcatheter closure of atrial septal defect and patent foramen ovale with occluders.

    PubMed

    Tang, Baiyu; Su, Feng; Sun, Xiangke; Wu, Qin; Xing, Quansheng; Li, Suming

    2018-01-01

    Atrial septal defect (ASD) and patent foramen ovale (PFO) are common clinical congenital heart defects. As an effective method for the treatment of ASD and PFO, transcatheter closure with occluders presents many advantages, including safety, ease of operation, minimal invasiveness, and reduced complications. This contribution reviews the various types of occluders currently used in clinical applications and under development, including non degradable occluders, partially degradable occluders, and totally degradable occluders. A number of case studies are described in detail. Comparison is made on the treatment outcomes using different occulders. Future development of transcatheter closure is discussed, in particular the use of totally degradable occluders. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 433-443, 2018. © 2016 Wiley Periodicals, Inc.

  12. A Taxonomy of 3D Occluded Objects Recognition Techniques

    NASA Astrophysics Data System (ADS)

    Soleimanizadeh, Shiva; Mohamad, Dzulkifli; Saba, Tanzila; Al-ghamdi, Jarallah Saleh

    2016-03-01

    The overall performances of object recognition techniques under different condition (e.g., occlusion, viewpoint, and illumination) have been improved significantly in recent years. New applications and hardware are shifted towards digital photography, and digital media. This faces an increase in Internet usage requiring object recognition for certain applications; particularly occulded objects. However occlusion is still an issue unhandled, interlacing the relations between extracted feature points through image, research is going on to develop efficient techniques and easy to use algorithms that would help users to source images; this need to overcome problems and issues regarding occlusion. The aim of this research is to review recognition occluded objects algorithms and figure out their pros and cons to solve the occlusion problem features, which are extracted from occluded object to distinguish objects from other co-existing objects by determining the new techniques, which could differentiate the occluded fragment and sections inside an image.

  13. Phonation Threshold Pressure Measurement With a Semi-Occluded Vocal Tract

    PubMed Central

    Titze, Ingo R.

    2015-01-01

    Purpose The purpose of this article was to determine if a semi-occluded vocal tract could be used to measure phonation threshold pressure. This is in contrast to the shutter technique, where an alternation between a fully occluded tract and an unoccluded tract is used. Method Five male and 5 female volunteers phonated through a thin straw held between the lips. Oral pressure behind the lips was measured. Mathematical predictions of phonation threshold pressures were compared to the measured ones over a range of frequencies. Results It was shown that, for a 2.5-mm diameter straw, phonation threshold pressures were obtainable over a 2-octave range of fundamental frequency by all volunteers. In magnitude, the pressures agreed with the 0.2–0.5 kPa values obtained in previous investigations. Sensitivity to viscoelastic and geometric properties of the vocal folds was generally not compromised with greater oral impedance, but some differences were predicted theoretically in contrast to an open mouth configuration. Conclusion Because phonation threshold pressure is always dependent on vocal tract interaction, it may be advantageous to choose an exact and fixed oral semi-occlusion for the measurement and interpret the results in light of the known acoustic load. PMID:19641082

  14. Dense Accumulation of Lipiodol Emulsion in Hepatocellular Carcinoma Nodule during Selective Balloon-occluded Transarterial Chemoembolization: Measurement of Balloon-occluded Arterial Stump Pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irie, Toshiyuki, E-mail: toshiyuki.irie.rq@hitachi.com; Kuramochi, Masashi, E-mail: masashi.kuramochi.sh@hitachi.com; Takahashi, Nobuyuki, E-mail: nbyktakahashiodn@yahoo.co.jp

    2013-06-15

    Purpose. To reveal the mechanism of dense accumulation of lipiodol emulsion (LE) in hepatocellular carcinoma (HCC) during selective balloon-occluded transarterial chemoembolization (B-TACE). Methods. Balloon-occluded arterial stump pressure (BOASP) at the embolization portion was measured during selective B-TACE for 43 nodules in 42 patients. Fluoroscopy and digital subtraction angiography were prospectively observed during selective B-TACE to note whether dense LE accumulation in HCC occurred. The LE concentration ratio of HCC to embolized liver parenchyma (LECHL ratio) was also calculated for each treatment on the basis of the computed tomographic scan obtained immediately after selective B-TACE. The relationships between degree of LEmore » accumulation and the BOASP, as well as the LECHL ratio, were analyzed. Results. Arterial flow beyond the catheter tip was maintained even after balloon inflation. In 39 of 43 treatments, LE inflow into the nontumorous liver parenchyma ceased immediately after LE droplets were filled in arteries of the nontumorous liver parenchyma while LE inflow into the HCC nodule continued (group 1). More dense LE accumulation in HCC nodule was obtained in these 39 treatments. In four treatments, LE inflow both into the nontumorous liver parenchyma and into the HCC nodule continued, and no dense LE accumulation in HCC nodule was observed (group 2). In these four treatments, thick anastomotic vessels with collateral artery were noted. The BOASP in group 1 was (mean {+-} SD) 33.8 {+-} 12.8 mmHg (range 13-64 mmHg) and that in group 2 was 92.3 {+-} 7.4 mmHg (range 83-100 mmHg). There was a statistically significant difference in BOASP between groups (p = 0.00004, Welch's t test). The LECHL ratio in group 1 was 18.3 {+-} 13.9 (range 2.9-54.2) and that in group 2 was 2.6 {+-} 1.1 (range 1.7-4.2). There was a statistically significant difference in the LECHL ratio between the groups (p = 0.000034, Welch's t test). Conclusion. Selective B

  15. Previous tip moth infestation predispose trees to heavier attacks in subsequent generations

    Treesearch

    Anthony R. Coody; Christopher J. Fettig; John T. Nowak; C. Wayne Berisford

    2000-01-01

    The Nantucket pine tip moth, Rhyacionia frustrana (Comstock) (Lepidoptera: Tortricidae), is a common regeneration pest of pine plantations in the southeastern U.S.A. The insect has two to five generations annually depending on climate (Fettig et al. 1999a, USDA For. Serv. Res. Pap., In press). Following oviposition and eclosion, first-instar larvae...

  16. Safety and efficacy of Cardi-O-fix occluder for percutaneous closure of a patent foramen ovale

    PubMed Central

    Zhao, Enfa; Liu, Wenjuan; Zhang, Yushun; Cheng, Gesheng; Du, Yajuan; He, Lu; Wang, Xingye; He, Xumei

    2017-01-01

    Abstract Background: Amplatzer occluder and Cardio-O-fix occluder are currently used in percutaneous closure of patent foramen ovale. However, there is still a lack of relevant reports comparison the differences between them. The aim of this study was to evaluate the short-term and mid-term safety and efficacy of the Cardi-O-fix occluder in preventing recurrent cerebrovascular events in patients with a patent foramen ovale (PFO). Methods: We enrolled 246 patients (105 men) with a PFO from May 30, 2013 to March 30, 2015 in this single-center prospective study. All patients were treated by PFO interventional closure, with the Cardi-O-fix PFO occluder being used in 180 patients and the Amplatzer PFO occluder being utilized in the remaining 66 patients. After the procedure, we verified the safety and efficacy of different devices using contrast transthoracic echocardiography. Results: Neither recurrent stroke nor death was encountered during the follow-up of 12 months. Transient ischemic attack (TIA) was noted in 2 patients (1.1%) in the Cardi-O-fix PFO occluder group, and 1 patient suffered from TIA (1.5%) in the Amplatzer PFO occluder group. Among them, only 1 patient exhibited a small right to left shunt (RLS). There was no statistical difference in recurrent cerebral ischemic events. Three cases of paroxysmal atrial fibrillation were observed in the Cardi-O-fix PFO occluder group. One reverted spontaneously to sinus rhythm and the other 2 cases had pharmacologic conversion to sinus rhythm. One case of paroxysmal atrial fibrillation occurred in the Amplatzer group, which underwent pharmacologic conversion to sinus rhythm. There was no significant difference between the 2 groups regarding incidence of arrhythmia. No occluder translocation, erosion, pericardial effusion, and puncture site bleeding were observed in the 2 groups within 12 months of follow-up. The complete closure rates of the Cardi-O-fix and Amplatzer PFO occluder devices at the 12 months after the

  17. Form Perception of Partly Occluded Shapes in 4-Month-Old Infants

    ERIC Educational Resources Information Center

    de Wit, Tessa C. J.; Vrins, Sven; Dejonckheere, Peter J. N.; van Lier, Rob

    2008-01-01

    Two habituation experiments were conducted to investigate how 4-month-old infants perceive partly occluded shapes. In the first experiment, we presented a simple, partly occluded shape to the infants until habituation was reached. Then we showed either a probable completion (one that would be predicted on the basis of both local and global cues)…

  18. Dynamic representation of partially occluded objects in primate prefrontal and visual cortex

    PubMed Central

    Choi, Hannah; Shea-Brown, Eric

    2017-01-01

    Successful recognition of partially occluded objects is presumed to involve dynamic interactions between brain areas responsible for vision and cognition, but neurophysiological evidence for the involvement of feedback signals is lacking. Here, we demonstrate that neurons in the ventrolateral prefrontal cortex (vlPFC) of monkeys performing a shape discrimination task respond more strongly to occluded than unoccluded stimuli. In contrast, neurons in visual area V4 respond more strongly to unoccluded stimuli. Analyses of V4 response dynamics reveal that many neurons exhibit two transient response peaks, the second of which emerges after vlPFC response onset and displays stronger selectivity for occluded shapes. We replicate these findings using a model of V4/vlPFC interactions in which occlusion-sensitive vlPFC neurons feed back to shape-selective V4 neurons, thereby enhancing V4 responses and selectivity to occluded shapes. These results reveal how signals from frontal and visual cortex could interact to facilitate object recognition under occlusion. PMID:28925354

  19. Identification and characterization of steady and occluded water in drinking water distribution systems.

    PubMed

    Tong, Huiyan; Zhao, Peng; Zhang, Hongwei; Tian, Yimei; Chen, Xi; Zhao, Weigao; Li, Mei

    2015-01-01

    Deterioration and leakage of drinking water in distribution systems have been a major issue in the water industry for years, which are associated with corrosion. This paper discovers that occluded water in the scales of the pipes has an acidic environment and high concentration of iron, manganese, chloride, sulfate and nitrate, which aggravates many pipeline leakage accidents. Six types of water samples have been analyzed under the flowing and stagnant periods. Both the water in the exterior of the tubercles and stagnant water carry suspended iron particles, which explains the occurrence of "red water" when the system hydraulic conditions change. Nitrate is more concentrated in occluded water under flowing condition in comparison with that in flowing water. However, the concentration of nitrate in occluded water under stagnant condition is found to be less than that in stagnant water. A high concentration of manganese is found to exist in steady water, occluded water and stagnant water. These findings impact secondary pollution and the corrosion of pipes and containers used in drinking water distribution systems. The unique method that taking occluded water from tiny holes which were drilled from the pipes' exteriors carefully according to the positions of corrosion scales has an important contribution to research on corrosion in distribution systems. And this paper furthers our understanding and contributes to the growing body of knowledge regarding occluded environments in corrosion scales. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Chemically etched fiber tips for near-field optical microscopy: a process for smoother tips.

    PubMed

    Lambelet, P; Sayah, A; Pfeffer, M; Philipona, C; Marquis-Weible, F

    1998-11-01

    An improved method for producing fiber tips for scanning near-field optical microscopy is presented. The improvement consists of chemically etching quartz optical fibers through their acrylate jacket. This new method is compared with the previous one in which bare fibers were etched. With the new process the meniscus formed by the acid along the fiber does not move during etching, leading to a much smoother surface of the tip cone. Subsequent metallization is thus improved, resulting in better coverage of the tip with an aluminum opaque layer. Our results show that leakage can be avoided along the cone, and light transmission through the tip is spatially limited to an optical aperture of a 100-nm dimension.

  1. Recognition of partially occluded threat objects using the annealed Hopefield network

    NASA Technical Reports Server (NTRS)

    Kim, Jung H.; Yoon, Sung H.; Park, Eui H.; Ntuen, Celestine A.

    1992-01-01

    Recognition of partially occluded objects has been an important issue to airport security because occlusion causes significant problems in identifying and locating objects during baggage inspection. The neural network approach is suitable for the problems in the sense that the inherent parallelism of neural networks pursues many hypotheses in parallel resulting in high computation rates. Moreover, they provide a greater degree of robustness or fault tolerance than conventional computers. The annealed Hopfield network which is derived from the mean field annealing (MFA) has been developed to find global solutions of a nonlinear system. In the study, it has been proven that the system temperature of MFA is equivalent to the gain of the sigmoid function of a Hopfield network. In our early work, we developed the hybrid Hopfield network (HHN) for fast and reliable matching. However, HHN doesn't guarantee global solutions and yields false matching under heavily occluded conditions because HHN is dependent on initial states by its nature. In this paper, we present the annealed Hopfield network (AHN) for occluded object matching problems. In AHN, the mean field theory is applied to the hybird Hopfield network in order to improve computational complexity of the annealed Hopfield network and provide reliable matching under heavily occluded conditions. AHN is slower than HHN. However, AHN provides near global solutions without initial restrictions and provides less false matching than HHN. In conclusion, a new algorithm based upon a neural network approach was developed to demonstrate the feasibility of the automated inspection of threat objects from x-ray images. The robustness of the algorithm is proved by identifying occluded target objects with large tolerance of their features.

  2. 21 CFR 882.5150 - Intravascular occluding catheter.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intravascular occluding catheter. 882.5150 Section 882.5150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5150 Intravascular...

  3. 21 CFR 882.5150 - Intravascular occluding catheter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intravascular occluding catheter. 882.5150 Section 882.5150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5150 Intravascular...

  4. Transcutaneous closure of chronic broncho-pleuro-cutaneous fistula by duct occluder device

    PubMed Central

    Marwah, Vikas; Ravikumar, R; Rajput, Ashok Kumar; Singh, Amandeep

    2016-01-01

    Bronchopleural fistula (BPF) is a well known complication of several pulmonary conditions posing challenging management problem and is often associated with high morbidity and mortality. Though no consensus exists on a definite closure management algorithm, strategies for closure widely include various methods like tube thoracostomy with suction, open surgical closure, bronchoscopy directed glue, coiling and sealants which now also includes use of occlusion devices. We report a case in which a novel method of delivery and closure of recurrent post-operative broncho-pleuro-cutaneous fistula by a duct occluder device was done transcutaneously which has not been previously described in literature. PMID:27051115

  5. The Role of Good Form in Young Infants' Perception of Partly Occluded Objects.

    ERIC Educational Resources Information Center

    Johnson, Scott P.; Bremner, J. Gavin; Slater, Alan M.; Mason, Uschi C.

    2000-01-01

    Three experiments investigated whether 4-month-olds would attend to and utilize the global configuration ("good form") of a partly occluded, moving object to perceive its unit and coherence behind the occluder. Results indicated that curvature per se provided information in support of completion, in addition to global configuration and…

  6. Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyer, Jules, E-mail: Jules.Dyer@nhs.net; Rosa, Joao; Chachlani, Menka

    PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed usingmore » the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.« less

  7. Distribution and Determinants of Myocardial Perfusion Grade Following Late Mechanical Recanalization of Occluded Infarct-Related Arteries Postmyocardial Infarction: A Report From the Occluded Artery Trial

    PubMed Central

    Jorapur, Vinod; Steigen, Terje K.; Buller, Christopher E.; Dẑavík, Vladimír; Webb, John G.; Strauss, Bradley H.; Yeoh, Eunice E.S.; Kurray, Peter; Sokalski, Leszek; Machado, Mauricio C.; Kronsberg, Shari S.; Lamas, Gervasio A.; Hochman, Judith S.; John Mancini, G.B.

    2010-01-01

    Objective To evaluate the distribution and determinants of myocardial perfusion grade (MPG) following late recanalization of persistently occluded infarct-related arteries (IRA). Background MPG reflects microvascular integrity. It is an independent prognostic factor following myocardial infarction, but has been studied mainly in the setting of early reperfusion. The occluded artery trial (OAT) enrolled stable patients with persistently occluded IRAs beyond 24 hr and up to 28 days post-MI. Methods Myocardial blush was assessed using TIMI MPG grading in 261 patients with TIMI 3 epicardial flow following IRA PCI. Patients demonstrating impaired (0–1) versus preserved (2–3) MPG were compared with regard to baseline clinical and pre-PCI angiographic characteristics. Results Impaired MPG was observed in 60 of 261 patients (23%). By univariate analysis, impaired MPG was associated with failed fibrinolytic therapy, higher heart rate, lower systolic blood pressure, lower ejection fraction, LAD occlusion, absence of collaterals (P < 0.01) and ST elevation MI, lower diastolic blood pressure, and higher systolic sphericity index (P < 0.05). By multivariable analysis, higher heart rate, LAD occlusion, absence of collaterals and higher systolic sphericity index (P < 0.01), and lower systolic blood pressure (P < 0.05) were independently associated with impaired MPG. Conclusion Preserved microvascular integrity was present in a high proportion of patients following late recanalization of occluded IRAs post-MI. Presence of collaterals was independently associated with preserved MPG and likely accounted for the high frequency of preserved myocardial perfusion in this clinical setting. Impaired MPG was associated with baseline clinical and angiographic features consistent with larger infarct size. PMID:18798327

  8. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II].

    PubMed

    Parra-Bravo, José Rafael; Osuna-Izaguirre, Manuel Alfredo; Beirana-Palencia, Luisa; Gálvez-Cancino, Franco; Martínez-Monterrosas, Christian; Lazo-Cárdenas, César; Reyes-Vargas, César

    2014-01-01

    In the last decades, several devices have been used for the percutaneous closure of patent ductus arteriosus, with its own limitations and risks. The Amplatzer Duct Occluder II has been designed to overcome those limitations and reduce risks. We described our initial series of patients who underwent percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder II, emphasis on the technical aspects of the procedure. We reviewed the clinical records of 9 patients with patent ductus arteriosus who underwent percutaneous closure with the Amplatzer Duct Occluder II. Median age was 24 months (range 8-51 months) and the median weight was 10.7kg (range 6-16.3kg). The minimal ductus arteriosus diameter was 2.7mm (1-5mm). Implantation was successful in all cases. The devices most commonly used (33.3%) were the dimensions 4-4mm (3 patients), in 2 patients were used 3-4mm and in the rest of the patients were employed occluder other sizes. Four cases showed slight residual flow immediately after implantation. Total closure was achieved in 24h in 8 of 9 patients (89%). There was no embolization of the occluder or deaths during the procedure and we only observed one minor complication. The Amplatzer Duct Occluder II in this series was effective in 89% of the patients at 24hs after the procedure and 100% follow-up. The implantation was safe and no major complications were observed. The occlusion rate is comparable to those reported for the Amplatzer Duct Occluder I. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  9. Amodal representation of occluded surfaces: role of invisible stimuli in apparent motion correspondence.

    PubMed

    Shimojo, S; Nakayama, K

    1990-01-01

    A series of demonstrations were created where the perceived depth of targets was controlled by stereoscopic disparity. A closer object (a cloud) was made to jump back and forth horizontally, partially occluding a farther object (a full moon). The more distant moon appeared stationary even though the unoccluded portion of it, a crescent, changed position. Reversal of the relative depth of the moon and cloud gave a totally different percept: the crescent appeared to flip back and forth in the front depth plane. Thus, the otherwise-robust apparent motion of the moon crescents was completely abolished in the cloud-closer case alone. This motion-blocking effect is attributed to the 'amodal presence' of the occluded surface continuing behind the occluding surface. To measure the effect of this occluded 'invisible' surface quantitatively, a bistable apparent motion display was used (Ramachandran and Anstis 1983a): two small rectangular-shaped targets changed their positions back and forth between two frames, and the disparity of a large centrally positioned rectangle was varied. When the perceived depths supported the possibility of amodal completion behind the large rectangle, increased vertical motion of the targets was found, suggesting that the amodal presence of the targets behind the occluder had effectively changed the center position of the moving targets for purposes of motion correspondence. Amodal contours are literally 'invisible', yet it is hypothesized that they have a neural representation at sufficiently early stages of visual processing to alter the correspondence solving process for apparent motion.

  10. ACTIVE DELIVERY CABLE TUNED TO DEVICE DEPLOYMENT STATE: ENHANCED VISIBILITY OF NITINOL OCCLUDERS DURING PRE-CLINICAL INTERVENTIONAL MRI

    PubMed Central

    Bell, Jamie A.; Saikus, Christina E.; Ratnayaka, Kanishka; Barbash, Israel M.; Faranesh, Anthony Z.; Franson, Dominique N.; Sonmez, Merdim; Slack, Michael C.; Lederman, Robert J.; Kocaturk, Ozgur

    2012-01-01

    Purpose To develop an active delivery system that enhances visualization of nitinol cardiac occluder devices during deployment under real-time MRI. Materials and Methods We constructed an active delivery cable incorporating a loopless antenna and a custom titanium microscrew to secure the occluder devices. The delivery cable was tuned and matched to 50Ω at 64 MHz with the occluder device attached. We used real-time balanced SSFP in a wide-bore 1.5T scanner. Device-related images were reconstructed separately and combined with surface-coil images. The delivery cable was tested in vitro in a phantom and in vivo in swine using a variety of nitinol cardiac occluder devices. Results In vitro, the active delivery cable provided little signal when the occluder device was detached and maximal signal with the device attached. In vivo, signal from the active delivery cable enabled clear visualization of occluder device during positioning and deployment. Device release resulted in decreased signal from the active cable. Post-mortem examination confirmed proper device placement. Conclusions The active delivery cable enhanced the MRI depiction of nitinol cardiac occluder devices during positioning and deployment, both in conventional and novel applications. We expect enhanced visibility to contribute to effectiveness and safety of new and emerging MRI-guided treatments. PMID:22707441

  11. The Cricoid Force Necessary to Occlude the Esophageal Entrance: Is There a Gender Difference?

    PubMed

    Zeidan, Ahed M; Salem, M Ramez; Bamadhaj, Munir; Mazoit, Jean-Xavier; Sadek, Hussein; Houjairy, Hassan; Abdulkhaleq, Kamal; Bamadhaj, Nabil

    2017-04-01

    We tested the hypothesis whether gender differences exist in the applied cricoid force necessary to prevent regurgitation. Real-time visual and dynamic means were used to assess the effectiveness of different applied cricoid forces in occluding the esophageal entrance in men (group 1) and in women (group 2). In anesthetized and paralyzed patients, the glottis and esophageal entrance were visualized with a Glidescope video laryngoscope. Trained operators performed cricoid pressure (CP) and gastric tube insertion trials. Successful gastric tube insertion in the presence of CP was considered ineffective CP, whereas unsuccessful insertion was considered effective CP. The applied cricoid forces were measured with a novel instrument, the cricometer. The first patient in each group received 20 N. The applied cricoid force in successive patients was determined by the response of the previous patient within the same group, using the up-and-down sequential allocation technique. In the 30 men and 30 women who qualified for the study, the median cricoid force (cricoid force = 50) that occluded the esophageal entrance was 30.8 N (95% confidence interval = 28.15-33.5) in men, and 18.7 N in women (95% confidence interval = 17.1-20.3; P < .0001). Patency of the esophageal entrance was observed when CP was not applied and when inadequate forces that allowed successful esophageal cannulation were used. The current study provides evidence that the median force necessary to occlude the esophageal entrance to prevent regurgitation is less in women compared with men. Applying the appropriate cricoid force in women should also decrease airway-related problems that tend to occur with the use of excessive forces. The findings of the current study may only be applicable to patients with normal body habitus.

  12. Modulation of occluding junctions alters the hematopoietic niche to trigger immune activation

    PubMed Central

    Khadilkar, Rohan J; Vogl, Wayne; Goodwin, Katharine

    2017-01-01

    Stem cells are regulated by signals from their microenvironment, or niche. During Drosophila hematopoiesis, a niche regulates prohemocytes to control hemocyte production. Immune challenges activate cell-signalling to initiate the cellular and innate immune response. Specifically, certain immune challenges stimulate the niche to produce signals that induce prohemocyte differentiation. However, the mechanisms that promote prohemocyte differentiation subsequent to immune challenges are poorly understood. Here we show that bacterial infection induces the cellular immune response by modulating occluding-junctions at the hematopoietic niche. Occluding-junctions form a permeability barrier that regulates the accessibility of prohemocytes to niche derived signals. The immune response triggered by infection causes barrier breakdown, altering the prohemocyte microenvironment to induce immune cell production. Moreover, genetically induced barrier ablation provides protection against infection by activating the immune response. Our results reveal a novel role for occluding-junctions in regulating niche-hematopoietic progenitor signalling and link this mechanism to immune cell production following infection. PMID:28841136

  13. Recognition of 3-D Scene with Partially Occluded Objects

    NASA Astrophysics Data System (ADS)

    Lu, Siwei; Wong, Andrew K. C...

    1987-03-01

    This paper presents a robot vision system which is capable of recognizing objects in a 3-D scene and interpreting their spatial relation even though some objects in the scene may be partially occluded by other objects. An algorithm is developed to transform the geometric information from the range data into an attributed hypergraph representation (AHR). A hypergraph monomorphism algorithm is then used to compare the AHR of objects in the scene with a set of complete AHR's of prototypes. The capability of identifying connected components and interpreting various types of edges in the 3-D scene enables us to distinguish objects which are partially blocking each other in the scene. Using structural information stored in the primitive area graph, a heuristic hypergraph monomorphism algorithm provides an effective way for recognizing, locating, and interpreting partially occluded objects in the range image.

  14. Safety, dose, and timing of reteplase in treating occluded central venous catheters in children with cancer.

    PubMed

    Terrill, Kelly R; Lemons, Richard S; Goldsby, Robert E

    2003-11-01

    Recombinant tissue plasminogen activator, alteplase, began to be commonly used to restore the patency of occluded central venous catheters (CVCs) as urokinase production was halted in the late 1990s. However, alteplase often requires an extended dwell time to restore patency to occluded CVCs. In adults, reteplase, a newer thrombolytic agent, has been reported to restore patency to CVCs in 30 minutes. The authors prospectively evaluated the safety and efficacy of reteplase in restoring patency to occluded CVCs in children with cancer. This was a dose escalation trial. The dose of reteplase was initiated at 0.1 units and increased by increments of 0.1 units to a maximum dose of 0.4 units. Each dose was tested on at least three participants. Time to patency after reteplase administration was recorded by nurses caring for the patients. Attempts to access the line occurred every 15 minutes for 1 hour. CVCs that remained occluded after 1 hour were treated with alteplase. Reteplase was administered to 15 clotted CVCs. Twelve of the 15 were cleared with an average dwell time of 38 minutes. The time to patency did not appear to correlate with the dose. No adverse events were reported. Reteplase can restore patency to occluded CVCs in a pediatric population. Reteplase appears to have comparable efficacy with alteplase, but reteplase may require shorter dwell times. A prospective, randomized, clinical trial is warranted to determine whether reteplase is as effective as alteplase in restoring patency to occluded CVCs.

  15. Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus.

    PubMed

    Wierzyk, Arkadiusz; Szkutnik, Małgorzata; Fiszer, Roland; Banaszak, Paweł; Pawlak, Szymon; Białkowski, Jacek

    2014-01-01

    Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurgical correction of tetralogy of Fallot (TOF). After the procedure, a significant haemodynamic residual VSD was observed, which was not successfully closed during the subsequent reoperation. Despite pharmacological treatment, symptoms of heart failure were observed in this patient. In echocardiographic images the residual VSD was presented as a tunnel-like dissection of the ventricular septum (length 6 mm and diameter 3.4 mm). The defect was closed via arterial access with an Amplatzer Duct Occluder II (ADO II). The procedure was successfully performed without any medical complications. In this child, a significant shunt reduction and a noticeable improvement in the patient's clinical status and diminished symptoms of heart failure were noticed. The second patient was a 4-year-old girl suffering from a multi-perforated perimembranous VSD accompanied by a ventricular septal defect with aneurysm. The defect was closed by a venous approach with a PDA Cardio-O-Fix occluder (very similar to ADO I). No short-term or long-term complications were visible during or after the procedure. Only a mild residual shunt through the VSD was observed 6 months afterwards. Transcatheter VSD closure with a proper morphology, with occluders of type Amplatzer Duct Occluder ADO I or ADO II, constitutes a safe and effective therapeutic alternative.

  16. Developments in Young Infants' Reasoning about Occluded Objects

    ERIC Educational Resources Information Center

    Aguiar, Andrea; Baillargeon, Renee

    2002-01-01

    Eight experiments were conducted to examine 3- and 3.5-month-old infants' responses to occlusion events. The results revealed two developments, one in infants' knowledge of when objects should and should not be occluded and the other in infants' ability to posit additional objects to make sense of events that would otherwise violate their…

  17. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder.

    PubMed

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-11-01

    Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  18. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    PubMed Central

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-01-01

    OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective. PMID:23184204

  19. Photodynamic therapy for occluded biliary metal stents

    NASA Astrophysics Data System (ADS)

    Roche, Joseph V. E.; Krasner, Neville; Sturgess, R.

    1999-02-01

    In this abstract we describe the use of photodynamic therapy (PDT) to recanalize occluded biliary metal stents. In patients with jaundice secondary to obstructed metal stents PDT was carried out 72 hours after the administration of m THPC. Red laser light at 652 nm was delivered endoscopically at an energy intensity of 50 J/cm. A week later endoscopic retrograde cholangiogram showed complete recanalization of the metal stent.

  20. Numerical procedure to determine geometric view factors for surfaces occluded by cylinders

    NASA Technical Reports Server (NTRS)

    Sawyer, P. L.

    1978-01-01

    A numerical procedure was developed to determine geometric view factors between connected infinite strips occluded by any number of infinite circular cylinders. The procedure requires a two-dimensional cross-sectional model of the configuration of interest. The two-dimensional model consists of a convex polygon enclosing any number of circles. Each side of the polygon represents one strip, and each circle represents a circular cylinder. A description and listing of a computer program based on this procedure are included in this report. The program calculates geometric view factors between individual strips and between individual strips and the collection of occluding cylinders.

  1. Cotton-Top Tamarins' ("Saguinus Oedipus") Expectations about Occluded Objects: A Dissociation between Looking and Reaching Tasks

    ERIC Educational Resources Information Center

    Santos, Laurie R.; Seelig, David; Hauser, Marc D.

    2006-01-01

    Recent work with human infants and toddlers suggests a dissociation between performance on looking and reaching tasks. Specifically, infants appear to generate accurate representations of occluded objects and their actions when tested in expectancy violation looking tasks but often fail to use this information when reaching for occluded objects.…

  2. Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.

    PubMed

    Karagöz, Tevfik; Akin, Alper; Ertuğrul, Ilker; Aykan, Hayrettin Hakan; Alehan, Dursun; Ozer, Sema; Ozkutlu, Süheyla

    2012-12-01

    The aim of our study was to share our clinical experience on cases with patent ductus arteriosus treated with the Amplatzer Duct Occluder II. Between 2008 and 2012, 26 of 31 patients with patent ductus arteriosus underwent successful transcatheter closure of patent ductus arteriosus using the Amplatzer Duct Occluder II. Mean age was 3.3 years and mean weight was 15.7 kilograms. The presence of a residual shunt, left pulmonary artery or aortic obstruction was explored by administering contrast material during the procedure. The patients were discharged 24 hours after the procedure. The procedure was successful in 26 of 31 patients and failed in five patients. According to the Krichenko classification, 26 patients had type A, one patient had type B and 4 patients had type C ductus. The mean narrowest ductus diameter was 3.2 mm and the mean ductus length was 6.7 mm. Complete angiographic occlusion occurred immediately after the procedure in 22 out of 26 patients in whom the ductus was closed successfully with the Amplatzer Duct Occluder II. Complete occlusion was achieved in the remaining patients with residual shunt one month after the procedure. The procedure was preceded by closure with an Amplatzer Duct Occluder I in two patients and an Amplatzer Vascular Plug I in one patient. Amplatzer Duct Occluder II is highly effective in transcatheter closure of patent ductus arteriosus. We think that an alternative closure device and alternative techniques can be attempted in patients with type C ductus. The success rate could increase with accumulating experience.

  3. Transcatheter Closure of Bilateral Multiple Huge Pulmonary Arteriovenous Malformations with Homemade Double-Umbrella Occluders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhong Hongshan, E-mail: zhonghongshan@hotmail.com; Xu Ke; Shao Haibo

    2008-07-15

    A 28-year-old man underwent successful transcatheter occlusion of three huge pulmonary arteriovenous malformations (PAVMs) using homemade double-umbrella occluders and stainless steel coils. Thoracic CT with three-dimensional reconstruction and pulmonary angiography were used for treatment planning and follow-up. The diameters of the feeding vessels were 11 mm, 13 mm, and 14 mm, respectively. This report demonstrates the novel design and utility of the double-umbrella occluder, an alternative tool for treatment of large PAVMs.

  4. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo.

    PubMed

    Zhang, Zhi xiong; Fu, Bu fang; Zhang, De yuan; Zhang, Zhi wei; Cheng, Yan; Sheng, Li yuan; Lai, Chen; Xi, Ting fei

    2013-04-01

    Atrial septal defect (ASD) occlusion devices made of nickel-titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium-nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.

    PubMed

    Celebi, Ahmet; Demir, Ibrahim Halil; Saritaş, Türkay; Dedeoğlu, Reyhan; Yucel, Ilker Kemal; Demir, Fadli; Erdem, Abdullah

    2013-11-15

    We sought to investigate the safety, efficacy, and follow-up results of percutaneous patent ductus arteriosus (PDA) closure using the novel Cardi-O-Fix duct occluder (CDO), a device similar to but less expensive than the Amplatzer duct occluder (ADO). We also aimed to compare these two devices in terms of results. Between March 2005 and May 2012, 167 patients diagnosed with moderate-to-large PDA underwent transcatheter closure. ADO was used in 56 (33.5%) patients with a mean age of 8.1 ± 11.9 years (3.6 months-56 years), whereas CDO was used in 111 (66.5%) patients with a mean age of 12.6 ± 14.6 years (4.8 months-63 years). The narrowest PDA diameter, the used device diameter, procedure time, fluoroscopy time, and residual shunt rates were similar between the two groups. Procedural success rate was 100% in both groups. Although the residual shunt rate was higher in the CDO group immediately after the procedure, the difference was not statistically significant (12.6 vs. 8.9%; P = 0.3). There was no statistically significant difference between groups at discharge and during follow-up. No deaths occurred in any of the groups, and there were no differences in complication rates during the short- and mid-term follow-up periods (CDO 7/111 vs. ADO 5/56; P = 0.5 π). The CDO can be used for PDA closure because of its safety, effectiveness, and simplicity in use. It is available in bigger sizes and can be used in patients with large defects. According to our short- and mid-term findings, the results it yields are similar to those of the ADO; thus, it may be the preferred choice owing to its low cost and large size variability. Copyright © 2013 Wiley Periodicals, Inc.

  6. Laser scoop desobliteration: a method for minimally invasive remote recanalization of chronically occluded superficial femoral arteries

    NASA Astrophysics Data System (ADS)

    Heneweer, Carola; Siggelkow, Markus; Helle, Michael; Petzina, Rainer; Wulff, Asmus; Schaefer, Joost P.; Berndt, Rouven; Rusch, Rene; Wedel, Thilo; Klaws, Guenther; Müller-Gerbl, Magdalena; Röcken, Christoph; Jansen, Olav; Lutter, Georg; Cremer, Joachim; Groß, Justus

    2015-02-01

    Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still poor. We present the first results with a catheter prototype for laser-based minimal invasive endarterectomy, called laser scoop desobliteration (LSD). The tip of a glass fiber containing a catheter was modified with a spatula head design and connected to an ultraviolet laser. It was tested in cadavers fixed with the Thiel embalming technique preserving tissue consistency, flexibility, and plasticity. After longitudinal arteriotomy of the SFA, a circular dissection between media and adventitia was performed. Then the LSD catheter was inserted and propagated with a progress of 1 mm/s. Afterward, the atheroma core, which showed a plain surface without substantial attaching tissue debris, was removed. Histological examination of the vessel wall showed that the dissection was performed at the media/adventitia interface. In summary, the constructed LSD catheter allowed a rapid and easy way to perform an endarterectomy, thereby offering an innovative approach in the treatment of chronic occluded SFA.

  7. Translation in cardiovascular stents and occluders: From biostable to fully degradable

    PubMed Central

    Huang, Yingying; Wong, Yee Shan; Ng, Herr Cheun Anthony; Boey, Freddy Y. C.

    2017-01-01

    Abstract Cardiovascular disease is a major cause of morbidity and mortality, especially in developed countries. Most academic research efforts in cardiovascular disease management focus on pharmacological interventions, or are concerned with discovering new disease markers for diagnosis and monitoring. Nonpharmacological interventions with therapeutic devices, conversely, are driven largely by novel materials and device design. Examples of such devices include coronary stents, heart valves, ventricular assist devices, and occluders for septal defects. Until recently, development of such devices remained largely with medical device companies. We trace the materials evolution story in two of these devices (stents and occluders), while also highlighting academic contributions, including our own, to the evolution story. Specifically, it addresses not only our successes, but also the challenges facing the translatability of concepts generated via academic research. PMID:29313029

  8. Externalized decondensed neutrophil chromatin occludes pancreatic ducts and drives pancreatitis

    PubMed Central

    Leppkes, Moritz; Maueröder, Christian; Hirth, Sebastian; Nowecki, Stefanie; Günther, Claudia; Billmeier, Ulrike; Paulus, Susanne; Biermann, Mona; Munoz, Luis E.; Hoffmann, Markus; Wildner, Dane; Croxford, Andrew L.; Waisman, Ari; Mowen, Kerri; Jenne, Dieter E.; Krenn, Veit; Mayerle, Julia; Lerch, Markus M.; Schett, Georg; Wirtz, Stefan; Neurath, Markus F.; Herrmann, Martin; Becker, Christoph

    2016-01-01

    Ductal occlusion has been postulated to precipitate focal pancreatic inflammation, while the nature of the primary occluding agents has remained elusive. Neutrophils make use of histone citrullination by peptidyl arginine deiminase-4 (PADI4) in contact to particulate agents to extrude decondensed chromatin as neutrophil extracellular traps (NETs). In high cellular density, NETs form macroscopically visible aggregates. Here we show that such aggregates form inside pancreatic ducts in humans and mice occluding pancreatic ducts and thereby driving pancreatic inflammation. Experimental models indicate that PADI4 is critical for intraductal aggregate formation and that PADI4-deficiency abrogates disease progression. Mechanistically, we identify the pancreatic juice as a strong instigator of neutrophil chromatin extrusion. Characteristic single components of pancreatic juice, such as bicarbonate ions and calcium carbonate crystals, induce aggregated NET formation. Ductal occlusion by aggregated NETs emerges as a pathomechanism with relevance in a plethora of inflammatory conditions involving secretory ducts. PMID:26964500

  9. Sound from a Two-Blade Propeller at Supersonic Tip Speeds

    NASA Technical Reports Server (NTRS)

    Hubbard, Harvey H; Lassiter, Leslie W

    1952-01-01

    Report presents the results of sound measurements at static conditions made for a two-blade 47-inch-diameter propeller in the tip Mach number range 0.75 to 1.30. For comparison, spectrums have been obtained at both subsonic and supersonic tip speeds. In addition, the measured data are compared with calculations by the theory of Gutin which has previously been found adequate for predicting the sound at subsonic tip speeds. Curves are presented from which the maximum over-all noise levels in free space may be estimated if the power, tip Mach number, and distance are known.

  10. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa

    PubMed Central

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Background: Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Methods: Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. Results: From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1–454 months) and the median weight was 8.5 kg (range 2.5–78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12–100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1–7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. Conclusion: The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients. PMID:28566820

  11. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa.

    PubMed

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1-454 months) and the median weight was 8.5 kg (range 2.5-78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12-100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1-7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients.

  12. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    PubMed

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  13. Template occluded SBA-15: An effective dissolution enhancer for poorly water-soluble drug

    NASA Astrophysics Data System (ADS)

    Tingming, Fu; Liwei, Guo; Kang, Le; Tianyao, Wang; Jin, Lu

    2010-09-01

    The aim of the present work was to improve the dissolution rate of piroxicam by inclusion into template occluded SBA-15. Our strategy involves directly introducing piroxicam into as-prepared SBA-15 occluded with P123 (EO 20PO 70EO 20) by self assembling method in acetonitrile/methylene chloride mixture solution. Ultraviolet spectrometry experiment and thermogravimetric analysis-differential scanning calorimetry (TG-DSC) profiles show that the piroxicam and P123 contents in the inclusion compound are 12 wt% and 28 wt%, respectively. X-ray powder diffraction and DSC analysis reveal that the included piroxicam is arranged in amorphous form. N 2 adsorption-desorption experiment indicates that the piroxicam has been introduced to the mesopores instead of precipitating at the outside of the silica material. The inclusion compound was submitted to in vitro dissolution tests, the results show that the piroxicam dissolve from template occluded inclusion compound more rapidly, than these from the piroxicam crystalline and template removed samples in all tested conditions. Thus a facile method to improve the dissolution rate of poorly water-soluble drug was established, and this discovery opens a new avenue for the utilization of templates used for the synthesis of mesoporous materials.

  14. Identifying the Optimal Water-Occluding Earplugs: A Scientific Simulation Study.

    PubMed

    Kovoor, Joshua; Al Hussaini, Ali; Backhouse, Steven

    2016-12-01

    Numerous types of water-occluding earplugs are available as a means of preventing infection in patients with external and middle ear disease. However, little is known about the comparative efficacies of these earplugs with prolonged water exposure. In this study, we assessed the water impermeability of various earplug materials to prolonged water exposure. Nine earplugs were tested: cotton wool mixed with petroleum jelly, cotton wool externally coated with petroleum jelly, Blu-Tack, foam earplugs, silicone putty, silicone earplugs, flanged earplugs, and hard and soft silicone custom-moulds. Precision-engineered cups were filled with 30 mL water and sealed with lids that contained a 10 mm diameter hole to simulate the ear canal. The aperture was occluded with different earplugs, and the cup was inverted. Computer software was used to record the water loss to the nearest 10 milligrams 720 times over a three-hour period. The test was repeated five times for each material. The water permeability onset, rate, and total amount of water loss varied markedly between the materials; cotton wool mixed with petroleum jelly demonstrated the fastest onset of leak and the highest rate of water loss (p < 0.00001), as well as the largest amount of cumulative water loss (p = 0.00213). The soft silicone custom-mould plugs, hard silicone custom-mould plugs, foam plugs, and silicone putty demonstrated no leaks. This study demonstrates a wide range of water permeabilities of commonly used ear-occluding materials during prolonged water exposure. We found that the generally suggested regimen of cotton wool mixed with petroleum jelly may be inefficacious for substantial periods of water exposure.

  15. Lack of benefit from percutaneous intervention of persistently occluded infarct arteries after the acute phase of myocardial infarction is time independent: insights from Occluded Artery Trial

    PubMed Central

    Menon, Venu; Pearte, Camille A.; Buller, Christopher E.; Steg, Ph.Gabriel; Forman, Sandra A.; White, Harvey D.; Marino, Paolo N.; Katritsis, Demosthenes G.; Caramori, Paulo; Lasevitch, Ricardo; Loboz-Grudzien, Krystyna; Zurakowski, Aleksander; Lamas, Gervasio A.; Hochman, Judith S.

    2009-01-01

    Aims The Occluded Artery Trial (OAT) (n = 2201) showed no benefit for routine percutaneous intervention (PCI) (n = 1101) over medical therapy (MED) (n = 1100) on the combined endpoint of death, myocardial infarction (MI), and class IV heart failure (congestive heart failure) in stable post-MI patients with late occluded infarct-related arteries (IRAs). We evaluated the potential for selective benefit with PCI over MED for patients enrolled early in OAT. Methods and results We explored outcomes with PCI over MED in patients randomized to the ≤3 calendar days and ≤7 calendar days post-MI time windows. Earlier, times to randomization in OAT were associated with higher rates of the combined endpoint (adjusted HR 1.04/day: 99% CI 1.01–1.06; P < 0.001). The 48-month event rates for ≤3 days, ≤7 days post-MI enrolled patients were similar for PCI vs. MED for the combined and individual endpoints. There was no interaction between time to randomization defined as a continuous (P = 0.55) or categorical variable with a cut-point of 3 days (P = 0.98) or 7 days (P = 0.64) post-MI and treatment effect. Conclusion Consistent with overall OAT findings, patients enrolled in the ≤3 day and ≤7 day post-MI time windows derived no benefit with PCI over MED with no interaction between time to randomization and treatment effect. Our findings do not support routine PCI of the occluded IRA in trial-eligible patients even in the earliest 24–72 h time window. PMID:19028780

  16. Remembering tips

    MedlinePlus

    Memory aids; Alzheimer disease - remembering tips; Early memory loss - remembering tips; Dementia - remembering tips ... harder for your brain to create a new memory, even while you can remember actions and events ...

  17. Dentinal tubules occluded by bioactive glass-containing toothpaste exhibit high resistance toward acidic soft drink challenge.

    PubMed

    Bakri, M M; Hossain, M Z; Razak, F A; Saqina, Z H; Misroni, A A; Ab-Murat, N; Kitagawa, J; Saub, R B

    2017-06-01

    Dentine hypersensitivity is a common problem attributed by patent dentinal tubules. Ingredients incorporated in toothpastes aim to occlude patent dentinal tubules to minimize the dentine hypersensitivity. However, frequent consumption of acidic soft drinks may reverse the dentinal tubules' occlusion. In this in vitro study, the efficacy of dentinal tubules occluded by commercially available toothpastes to withstand different durations of an acidic soft drink challenge was investigated. One hundred and twenty dentine discs were divided into three groups. The discs from each group were brushed with toothpaste containing bioactive glass, arginine and control toothpaste. Each group was then divided into four subgroups and exposed to acidic soft drink over four different time durations. The scoring and the percentage of occluded dentinal tubules by Novamin-containing toothpaste was significantly better compared with arginine or the control toothpaste. Acidic soft drink challenge reduced the extent of dentinal tubules occlusion along with time. Dentinal tubules occluded by Novamin-containing toothpaste withstand the acidic challenge comparatively for a longer period. The findings demonstrated that occlusion of dentinal tubules is more efficient by the bioactive glass-containing toothpaste and thus may contribute to its better resistance to acidic soft drink challenge. © 2016 Australian Dental Association.

  18. Electronic eye occluder with time-counting and reflection control

    NASA Astrophysics Data System (ADS)

    Karitans, V.; Ozolinsh, M.; Kuprisha, G.

    2008-09-01

    In pediatric ophthalmology 2 - 3 % of all the children are impacted by a visual pathology - amblyopia. It develops if a clear image isn't presented to the retina during an early stage of the development of the visual system. A common way of treating this pathology is to cover the better-seeing eye to force the "lazy" eye to learn seeing. However, children are often reluctant to wear such an occluder because they are ashamed or simply because they find it inconvenient. This fact requires to find a way how to track the regime of occlusion because results of occlusion is a hint that the actual regime of occlusion isn't that what the optometrist has recommended. We design an electronic eye occluder that allows to track the regime of eye occlusion. We employ real-time clock DS1302 providing time information from seconds to years. Data is stored in the internal memory of the CPU (EEPROM). The MCU (PIC16F676) switches on only if a mechanical switch is closed and temperature has reached a satisfactory level. The occlusion is registered between time moments when the infrared signal appeared and disappeared.

  19. Occluded Brescia-Cimino Hemodialysis Fistulas: Endovascular Treatment with Both Brachial Arterial and Venous Access Using the Pull-Through Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi

    2005-12-15

    We retrospectively evaluated the usefulness of both arterial and venous access with the pull-through technique in endovascular treatment of totally occluded Brescia-Cimino fistulas. We treated 26 patients (17 men, 9 women; age range 43-82 years, mean age 66 years) with occluded Brescia-Cimino fistulas. First, the occluded segment was traversed from the antegrade brachial arterial access using a microcatheter-guidewire system. Second, the vein was retrogradely punctured after confirmation of all diseased segments, and a 0.014- or 0.016-inch guidewire was pulled through the venous access when the occluded segment was long. All interventions including thrombolysis, thromboaspiration, angioplasty, and stent placement were performedmore » via the venous access. The occlusion was successfully crossed via the brachial arterial access in 23 patients (88%). In 2 patients it was done from the venous approach. In the remaining patient it was not possible to traverse the occluded segment. The pull-through technique was successful in all 19 attempts. Clinical success was achieved in 96%, the primary patency rates at 6, 12, and 18 months were 83%, 78%, and 69%, the primary assisted patency rates were 92%, 92%, and 72%, and the secondary patency rates were 92%, 92%, and 92%, respectively. Minor complications in 5 patients included venous perforation in 2 (8%), venous rupture in 1 (4%), and regional hematoma in 2 (8%). Our study suggests that endovascular treatments with both arterial and venous access using the pull-through technique are highly effective in restoring function in totally occluded Brescia-Cimino fistulas.« less

  20. Numerical analysis of turbine blade tip treatments

    NASA Technical Reports Server (NTRS)

    Gopalaswamy, Nath S.; Whitaker, Kevin W.

    1992-01-01

    Three-dimensional solutions of the Navier-Stokes equations for a turbine blade with a turning angle of 180 degrees have been computed, including blade tip treatments involving cavities. The geometry approximates a preliminary design for the GGOT (Generic Gas Oxidizer Turbine). The data presented here will be compared with experimental data to be obtained from a linear cascade using original GGOT blades. Results have been computed for a blade with 1 percent clearance, based on chord, and three different cavity sizes. All tests were conducted at a Reynolds number of 4 x 10 exp 7. The grid contains 39,440 points with 10 spanwise planes in the tip clearance region of 5.008E-04 m. Streamline plots and velocity vectors together with velocity divergence plots reveal the general flow behavior in the clearance region. Blade tip temperature calculations suggest placement of a cavity close to the upstream side of the blade tip for reduction of overall blade tip temperature. The solutions do not account for the relative motion between the endwall and the turbine blade. The solutions obtained are generally consistent with previous work done in this area,

  1. A unified computational model of the development of object unity, object permanence, and occluded object trajectory perception.

    PubMed

    Franz, A; Triesch, J

    2010-12-01

    The perception of the unity of objects, their permanence when out of sight, and the ability to perceive continuous object trajectories even during occlusion belong to the first and most important capacities that infants have to acquire. Despite much research a unified model of the development of these abilities is still missing. Here we make an attempt to provide such a unified model. We present a recurrent artificial neural network that learns to predict the motion of stimuli occluding each other and that develops representations of occluded object parts. It represents completely occluded, moving objects for several time steps and successfully predicts their reappearance after occlusion. This framework allows us to account for a broad range of experimental data. Specifically, the model explains how the perception of object unity develops, the role of the width of the occluders, and it also accounts for differences between data for moving and stationary stimuli. We demonstrate that these abilities can be acquired by learning to predict the sensory input. The model makes specific predictions and provides a unifying framework that has the potential to be extended to other visual event categories. Copyright © 2010 Elsevier Inc. All rights reserved.

  2. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    NASA Astrophysics Data System (ADS)

    Rubino, Caroline

    points were used to sample the peri-implant sulcus bacteria. All samples were then submitted to DNA purification, polymerase chain reaction (PCR), and sequencing protocols to assess relative numbers of bacterial species. Periodontal parameters were collected at both time points. Overall, our findings support several conclusions. Different implant abutment channel occluding materials appear to have no effect on the amount of observed microleakage and the peri-implant microbiome. Evidence for microleakage was found in the present study, corroborating existing in vivo evidence. Finally, we gained several insights regarding the peri implant microbiome. Of note, the peri-implant microbiome is well described by the classical periodontal microbial complexes, but a large portion consists of bacteria not previously classified into the microbial complexes.

  3. Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder.

    PubMed

    Yu, Man-Li; Huang, Xin-Miao; Wang, Jia-Feng; Qin, Yong-Wen; Zhao, Xian-Xian; Zheng, Xing

    2009-11-01

    Most occurrences of large patent ductus arteriosus (PDAs) of > or =10 mm have been surgically closed, and transcatheter closure of these large PDAs was only reported in a few case reports. The present study reviewed our experience in transcatheter closure of such large PDAs with a Chinese self-expandable occluder, which is similar to but much cheaper than the Amplatzer occluder. From July 2000 to January 2008, 23 patients underwent transcatheter closure of large PDA > or =10 mm with this kind of occluder. The mean (SD) age of the patients was 38.0 (15.6) years (range 18-75 years). Radiographs of the chest, electrocardiograms, and echocardiograms were used for follow-up evaluation of the treatment within 1 day, 1 month, 6 months, and then every year after successful closure. The mean (SD) angiographic PDA diameter was 12.8 (2.6) mm (range 10-18 mm) and the mean occluder diameter was 18.0 (2.9) mm (range 16-22 mm). The occluders were delivered successfully and closed the PDA completely in 19 out of the 23 patients. Pulmonary arterial pressures decreased significantly after occlusion in patients with successful treatment: 67.3 (24.7) mmHg (range 29-122 mmHg) before occlusion and 42.3 (22.0) mmHg (range 19-98 mmHg) immediately after the procedure. Radiographs of the chest and echocardiograms showed that the diameters of the left atrium, left ventricle, and the main pulmonary artery decreased, and the ejection fraction (EF) increased at a mean (SD) follow-up of 36.3 (18.7) months (range 6-72 months). No severe complication occurred. The immediate and long-term outcomes suggested that transcatheter closure of PDAs with the native PDA occluder is a safe and effective treatment for adults with large PDA > or =10 mm.

  4. Association between autistic traits and emotion adaptation to partially occluded faces.

    PubMed

    Luo, Chengwen; Burns, Edwin; Xu, Hong

    2017-04-01

    Prolonged exposure to a happy face makes subsequently presented faces appear sadder: the facial emotion aftereffect (FEA). People with autism spectrum disorders and their relatives have diminished holistic perception of faces. Levels of autism can be measured continuously in the general population by autistic traits using the autism-quotient (AQ). Prior work has not found any association between AQ and FEA in adults, possibly due to non-holistic processing strategies employed by those at the higher end of the spectrum. In the present study, we tested whether AQ was associated with FEA to partially occluded faces. We hypothesized that inferring emotion from such faces would require participants to process their viewable parts as a gestalt percept, thus we anticipated this ability would diminish as autistic traits increased. In Experiment 1, we partially occluded the adapting faces with aligned or misaligned opaque bars. Both conditions produced significant FEAs, with aftereffects and AQ negatively correlated. In Experiment 2, we adapted participants to obscured faces flickering in luminance, and manipulated the facilitation of holistic perception by varying the synchronization of this flickering. We found significant FEAs in all conditions, but abolished its association with AQ. In Experiment 3, we showed that the association between AQ and FEA in the occluded conditions in Experiment 1 was not due to the recognizability or perceived emotional intensity of our adaptors; although the overall FEAs were linked to emotional intensity. We propose that increasing autistic traits are associated with diminishing abilities in perceiving emotional faces as a gestalt percept. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Lateral Tip Control Effects in CD-AFM Metrology: The Large Tip Limit.

    PubMed

    Dixson, Ronald G; Orji, Ndubuisi G; Goldband, Ryan S

    2016-01-25

    Sidewall sensing in critical dimension atomic force microscopes (CD-AFMs) usually involves continuous lateral dithering of the tip or the use of a control algorithm and fast response piezo actuator to position the tip in a manner that resembles touch-triggering of coordinate measuring machine (CMM) probes. All methods of tip position control, however, induce an effective tip width that may deviate from the actual geometrical tip width. Understanding the influence and dependence of the effective tip width on the dither settings and lateral stiffness of the tip can improve the measurement accuracy and uncertainty estimation for CD-AFM measurements. Since CD-AFM typically uses tips that range from 15 nm to 850 nm in geometrical width, the behavior of effective tip width throughout this range should be understood. The National Institute of Standards and Technology (NIST) has been investigating the dependence of effective tip width on the dither settings and lateral stiffness of the tip, as well as the possibility of material effects due to sample composition. For tip widths of 130 nm and lower, which also have lower lateral stiffness, the response of the effective tip width to lateral dither is greater than for larger tips. However, we have concluded that these effects will not generally result in a residual bias, provided that the tip calibration and sample measurement are performed under the same conditions. To validate that our prior conclusions about the dependence of effective tip width on lateral stiffness are valid for large CD-tips, we recently performed experiments using a very large non-CD tip with an etched plateau of approximately 2 μm width. The effective lateral stiffness of these tips is at least 20 times greater than typical CD-AFM tips, and these results supported our prior conclusions about the expected behavior for larger tips. The bottom-line importance of these latest observations is that we can now reasonably conclude that a dither slope of 3 nm

  6. Lateral Tip Control Effects in CD-AFM Metrology: The Large Tip Limit

    PubMed Central

    Dixson, Ronald G.; Orji, Ndubuisi G.; Goldband, Ryan S.

    2016-01-01

    Sidewall sensing in critical dimension atomic force microscopes (CD-AFMs) usually involves continuous lateral dithering of the tip or the use of a control algorithm and fast response piezo actuator to position the tip in a manner that resembles touch-triggering of coordinate measuring machine (CMM) probes. All methods of tip position control, however, induce an effective tip width that may deviate from the actual geometrical tip width. Understanding the influence and dependence of the effective tip width on the dither settings and lateral stiffness of the tip can improve the measurement accuracy and uncertainty estimation for CD-AFM measurements. Since CD-AFM typically uses tips that range from 15 nm to 850 nm in geometrical width, the behavior of effective tip width throughout this range should be understood. The National Institute of Standards and Technology (NIST) has been investigating the dependence of effective tip width on the dither settings and lateral stiffness of the tip, as well as the possibility of material effects due to sample composition. For tip widths of 130 nm and lower, which also have lower lateral stiffness, the response of the effective tip width to lateral dither is greater than for larger tips. However, we have concluded that these effects will not generally result in a residual bias, provided that the tip calibration and sample measurement are performed under the same conditions. To validate that our prior conclusions about the dependence of effective tip width on lateral stiffness are valid for large CD-tips, we recently performed experiments using a very large non-CD tip with an etched plateau of approximately 2 μm width. The effective lateral stiffness of these tips is at least 20 times greater than typical CD-AFM tips, and these results supported our prior conclusions about the expected behavior for larger tips. The bottom-line importance of these latest observations is that we can now reasonably conclude that a dither slope of 3 nm

  7. Endovascular treatment of occluded and stenotic visceral vessels in patients with chronic mesenteric ischemia.

    PubMed

    Christofi, Georgia; Donas, Konstantinos P; Pitoulias, Georgios A; Torsello, Giovanni; Schwindt, Arne G; Stavroulakis, Konstantinos

    2017-02-01

    Objective Current evidence in the literature about endovascular treatment (ET) of visceral vessels in patients with chronic mesenterial ischemia (CMI) based on morphological characteristics is limited. The aim of this study was the evaluation of ET in occluded and stenotic visceral vessels. Methods Patients undergoing ET for CMI between November 2000 and November 2012 were included in this retrospective study. Primary measure outcome was the symptom-free survival (SFS). Secondary outcomes were primary (PPR), secondary patency (SPR) rates and technical success rate (TSR). A Cox-regression analysis identified risk factors for the primary and secondary measure outcomes. Results Forty patients were included in the present study (men: 21, mean age: 68). The overall number of vessels with intention-to-treat was 62. Fifty-two visceral arteries (18 occlusions and 34 stenoses) were successfully treated by endovascular means. The overall TSR was 84%. Visceral vessel occlusions and atherosclerotic disease of the superior mesenteric artery (SMA) were identified as independent risk factors for poorer TSR ( p < 0.05). The 12-month SFS was 60%. The overall 12-month PPR and SPR were 71% and 94%, respectively. No significant differences were observed between occluded and stenotic vessels ( p > 0.05) concerning the PPR. On the other hand, the subgroup analysis revealed higher SPR among occluded visceral vessels ( p < 0.001) and coeliac axis lesions ( p < 0.001). Conclusions ET was associated with high incidence of symptoms recurrence despite the satisfying patency rates in both occluded and stenotic vessels. Additionally, visceral vessel occlusion and presence of atherosclerotic lesions in the SMA were associated with poorer TSR.

  8. Transcatheter closure of left ventricle to right atrial communication using cera duct occluder.

    PubMed

    Ganesan, Gnanavelu; Paul, G Justin; Mahadevan, Vaikom S

    Left ventricle-right atrial communication could be congenital (Gerbode defect) or acquired as a complication of surgery or infective endocarditis and leads to volume overloading of pulmonary circulation. Two types, direct and indirect types are known depending on the involvement of septal tricuspid leaflet. Transcatheter closure of this defect is feasible and appears an attractive alternative to surgical management. Various devices like Amplatzer duct occluder I, II, Muscular ventricular septal defect device etc. have been used to close this defect. We report two patients, a preteen boy with direct left ventricle-right atrial communication as post operative complication and an adult female with indirect communication who underwent transcatheter closure with Cera duct occluder (Lifetech Scientific (Shenzhen), China). Copyright © 2017. Published by Elsevier B.V.

  9. Numerical investigation of tip clearance effects on the performance of ducted propeller

    NASA Astrophysics Data System (ADS)

    Ding, Yongle; Song, Baowei; Wang, Peng

    2015-09-01

    Tip clearance loss is a limitation of the improvement of turbomachine performance. Previous studies show the Tip clearance loss is generated by the leakage flow through the tip clearance, and is roughly linearly proportional to the gap size. This study investigates the tip clearance effects on the performance of ducted propeller. The investigation was carried out by solving the Navier-Stokes equations with the commercial Computational Fluid Dynamic (CFD) code CFX14.5. These simulations were carried out to determine the underlying mechanisms of the tip clearance effects. The calculations were performed at three different chosen advance ratios. Simulation results showed that the tip loss slope was not linearly at high advance due to the reversed pressure at the leading edge. Three type of vortical structures were observed in the tip clearance at different clearance size.

  10. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  11. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  12. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  13. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  14. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  15. Intuitive physical reasoning about occluded objects by inexperienced chicks

    PubMed Central

    Chiandetti, Cinzia; Vallortigara, Giorgio

    2011-01-01

    Questions concerning the role of nature and nurture in higher cognition appear to be intractable if one restricts one's attention to development in humans. However, in other domains, such as sensory development, much information has been gained from controlled rearing studies with animals. Here, we used a similar experimental strategy to investigate intuitive reasoning about occluded objects. Newborn domestic chicks (Gallus gallus) were reared singly with a small object that became their social partner. They were then accustomed to rejoin such an imprinting object when it was made to move and disappear behind either one of two identical opaque screens. After disappearance of the imprinting object, chicks were faced with two screens of different slants, or of different height or different width, which may or may not have been compatible with the presence of the imprinting object hidden beneath/behind them. Chicks consistently chose the screen of slant/height/width compatible with the presence of the object beneath/behind it. Preventing chicks from touching and pecking at the imprinting object before testing did not affect the results, suggesting that intuitive reasoning about physical objects is largely independent of specific experience of interaction with objects and of objects' occluding events. PMID:21270036

  16. The Evolution of Transjugular Intrahepatic Portosystemic Shunt: Tips

    PubMed Central

    Fanelli, Fabrizio

    2014-01-01

    Since Richter's description in the literature in 1989 of the first procedure on human patients, transjugular intrahepatic portosystemic shunt (TIPS) has been worldwide considered as a noninvasive technique to manage portal hypertension complications. TIPS succeeds in lowering the hepatic sinusoidal pressure and in increasing the circulatory flow, thus reducing sodium retention, ascites recurrence, and variceal bleeding. Required several revisions of the shunt TIPS can be performed in case of different conditions such as hepatorenal syndrome, hepatichydrothorax, portal vein thrombosis, and Budd-Chiari syndrome. Most of the previous studies on TIPS procedure were based on the use of bare stents and most patients chose TIPS 2-3 years after traditional treatment, thus making TIPS appear to be not superior to endoscopy in survival rates. Bare stents were associated with higher incidence of shunt failure and consequently patients required several revisions during the follow-up. With the introduction of a dedicated e-PTFE covered stent-graft, these problems were completely solved, No more reinterventions are required with a tremendous improvement of patient's quality of life. One of the main drawbacks of the use of e-PTFE covered stent-graft is higher incidence of hepatic encephalopathy. In those cases refractory to the conventional medical therapy, a shunt reduction must be performed. PMID:27335841

  17. Comparison of three patent foramen ovale closure devices in a randomized trial (Amplatzer versus CardioSEAL-STARflex versus Helex occluder).

    PubMed

    Taaffe, Margaret; Fischer, Evelyn; Baranowski, Andreas; Majunke, Nicolas; Heinisch, Corinna; Leetz, Michaela; Hein, Ralph; Bayard, Yves; Büscheck, Franziska; Reschke, Madlen; Hoffmann, Ilona; Wunderlich, Nina; Wilson, Neil; Sievert, Horst

    2008-05-01

    This randomized trial compared procedural complications and 30-day clinical outcomes of 3 patent foramen ovale (PFO) closure devices (Amplatzer, Helex, and CardioSEAL-STARflex). It examined 660 patients (361 men, 299 women, mean age 49.3+/-1.9 years), with 220 patients per group. All patients had a history of paradoxical embolism. All PFO closures were successful technically. Exchange of devices for others was most frequently required for the Helex occluder (7 of 220) and 2 of 220 in either of the other groups. Three device embolizations in the Helex group were retrieved and replaced successfully. One patient with a Helex occluder developed a transient ischemic attack and recovered without treatment. A hemopericardium in that group was punctured without affecting the device. One tamponade in the Amplatzer group required surgical device explantation. In 8 of 660 patients in the CardioSEAL-STARflex group, thrombi resolved after anticoagulation. Sixteen patients (11 in the CardioSEAL-STARflex group, 3 in the Amplatzer group, and 2 in the Helex group) had episodes of atrial fibrillation. PFOs were closed completely in 143 of 220 patients (65%) in the Amplatzer group, 116 of 220 patients (52.7%) in the Helex group, and 137 of 220 patients (62.3%) in the CardioSEAL-STARflex group at 30 days with significant differences between the Helex and Amplatzer occluders (p=0.0005) and the Helex and CardioSEAL-STARflex occluders (p=0.0003). PFO closure can be performed safely with each device. In conclusion, the Helex occluder embolized more frequently. Device thrombus formation and paroxysmal atrial fibrillation were more common with the CardioSEAL-STARflex occluder.

  18. Application of Cardio-O-Fix occluders for transcatheter closure of patent ductus arteriosus and interatrial communications: Preliminary experience.

    PubMed

    Białkowski, Jacek; Szkutnik, Małgorzata; Fiszer, Roland; Głowacki, Jan; Banaszak, Paweł; Zembala, Marian

    2010-01-01

    Transcatheter treatment has become the method of choice for treating many heart defects. Recently, Cardio-O-Fix occluder (COF) - a new, self-expandable nitinol wire-mesh device very similar to the Amplatzer device - has been introduced into clinical practice. To the best of our knowledge, this is the first publication related to its application. Five patients aged from six months to 69 years were included in the study: two with atrial septal defect (ASD), one with patent foramen ovale (PFO) after cryptogenic stroke, and two with patent ductus arteriosus (PDA). These latter two comprised one six month old infant with co-existent hypertrophied cardiomyopathy, and a 53 year-old woman with recanalized PDA after previous ligation. All were treated percutaneously with COF. There was no preliminary patient selection. The only limitation was the size of the devices in our possession (16 and 22 mm ASD COF, 25 PFO COF, 4/6 and 6/8 PDA COF). The implantation technique was the same as previously described for Amplatzer occluders. All procedures were finished successfully with complete closure of the shunt. No complications were observed during a six month follow-up. In the child with PDA, we observed decrease of gradient from 80 to 60 mm Hg in hypertrophied left ventricular outflow tract, although a small protrusion of PDA-COF device was noted in the descending aorta (8 mm Hg gradient in ECHO). In the patient with recanalized PDA, the procedure was performed after arterio-venous loop creation. Mean fluoroscopy time was 4.4 (range from 1.6 to 11) minutes. Our preliminary experience indicates that the application of Cardio-O-Fix devices is safe and effective.

  19. Influence of blade tip rounding on tip leakage vortex cavitation of axial flow pump

    NASA Astrophysics Data System (ADS)

    Wu, S. Q.; Shi, W. D.; Zhang, D. S.; Yao, J.; Cheng, C.

    2013-12-01

    Tip leakage flow in axial flow pumps is mainly caused by the tip clearance, which is the main cause of tip leakage vortex cavitation and blade tip cavitation erosion. In order to improve tip clearance flow and reduce TLV cavitation, four schemes were adopted to the round blade tip. These are: no tip rounding, one time tip clearance tip rounding, two times tip clearance tip rounding, four times tip clearance tip rounding. Using SST k-ω turbulence model and Zwart cavitation model in CFX software, this simulation obtained four kinds of inner flow field results. The numerical results indicated that with the increase of r*, NPSHc gradually increased and the cavitation performance reduced. However, corner vortex was eliminated so that cavitation in gap was restrained. But TLV vorticity increased and cavitation's range here had a little expansion. Combined with the research of this paper and the different analyses of four schemes, we recommend adopting the two times of the tip clearance rounding.

  20. Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation

    NASA Astrophysics Data System (ADS)

    de Saint Victor, M.; Carugo, D.; Barnsley, L. C.; Owen, J.; Coussios, C.-C.; Stride, E.

    2017-09-01

    Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100 mm s-1 (corresponding to Reynolds numbers 0.25-25) (ii) the transport dynamics of fibrinolytic drugs; and (iii) the flow behavior of microbubbles with diameters in the clinically-relevant range (0.6-5 µm). In vitro experiments were carried out in a custom-built microfluidic device. The flow field was characterized using tracer particles, and fibrinolytic drug transport was assessed using fluorescence microscopy. Lipid-shelled magnetic microbubbles were fluorescently labelled to determine their spatial distribution within the microvascular model. In both the simulations and experiments, the formation of laminar vortices and an abrupt reduction of fluid velocity were observed in the occluded branch of the bifurcation, severely limiting drug transport towards the occlusion. In the absence of a magnetic field, no microbubbles reached the occlusion, remaining trapped in the first vortex, within 350 µm from the bifurcation center. The number of microbubbles trapped within the vortex decreased as the inlet velocity increased, but was independent of microbubble size. Application of a magnetic field (magnetic flux density of 76 mT, magnetic flux density gradient of 10.90 T m-1 at the centre of the bifurcation) enabled delivery of microbubbles to the occlusion and the number of microbubbles delivered increased with bubble size and with decreasing inlet velocity.

  1. Improved Temperature Dynamic Model of Turbine Subcomponents for Facilitation of Generalized Tip Clearance Control

    NASA Technical Reports Server (NTRS)

    Kypuros, Javier A.; Colson, Rodrigo; Munoz, Afredo

    2004-01-01

    This paper describes efforts conducted to improve dynamic temperature estimations of a turbine tip clearance system to facilitate design of a generalized tip clearance controller. This work builds upon research previously conducted and presented in and focuses primarily on improving dynamic temperature estimations of the primary components affecting tip clearance (i.e. the rotor, blades, and casing/shroud). The temperature profiles estimated by the previous model iteration, specifically for the rotor and blades, were found to be inaccurate and, more importantly, insufficient to facilitate controller design. Some assumptions made to facilitate the previous results were not valid, and thus improvements are presented here to better match the physical reality. As will be shown, the improved temperature sub- models, match a commercially validated model and are sufficiently simplified to aid in controller design.

  2. Balloon-Occluded Percutaneous Transhepatic Obliteration of Isolated Vesical Varices Causing Gross Hematuria

    PubMed Central

    Lim, Dong Hoon; Kim, Min Seok; Kim, Chul Sung

    2013-01-01

    Gross hematuria secondary to vesical varices is an unusual presentation. We report such a case recurrent gross hematuria in a male patient who had a history of bladder substitution with ileal segments that had been treated by balloon-occluded percutaneous transhepatic obliteration of vesical varices. PMID:23323037

  3. Comparison of Various Supersonic Turbine Tip Designs to Minimize Aerodynamic Loss and Tip Heating

    NASA Technical Reports Server (NTRS)

    Shyam, Vikram; Ameri, Ali

    2012-01-01

    The rotor tips of axial turbines experience high heat flux and are the cause of aerodynamic losses due to tip clearance flows, and in the case of supersonic tips, shocks. As stage loadings increase, the flow in the tip gap approaches and exceeds sonic conditions. This introduces effects such as shock-boundary layer interactions and choked flow that are not observed for subsonic tip flows that have been studied extensively in literature. This work simulates the tip clearance flow for a flat tip, a diverging tip gap and several contoured tips to assess the possibility of minimizing tip heat flux while maintaining a constant massflow from the pressure side to the suction side of the rotor, through the tip clearance. The Computational Fluid Dynamics (CFD) code GlennHT was used for the simulations. Due to the strong favorable pressure gradients the simulations assumed laminar conditions in the tip gap. The nominal tip gap width to height ratio for this study is 6.0. The Reynolds number of the flow is 2.4 x 10(exp 5) based on nominal tip width and exit velocity. A wavy wall design was found to reduce heat flux by 5 percent but suffered from an additional 6 percent in aerodynamic loss coefficient. Conventional tip recesses are found to perform far worse than a flat tip due to severe shock heating. Overall, the baseline flat tip was the second best performer. A diverging converging tip gap with a hole was found to be the best choice. Average tip heat flux was reduced by 37 percent and aerodynamic losses were cut by over 6 percent.

  4. In vitro experiments of cerebral blood flow during aspiration thrombectomy: potential effects on cerebral perfusion pressure and collateral flow.

    PubMed

    Lally, Frank; Soorani, Mitra; Woo, Timothy; Nayak, Sanjeev; Jadun, Changez; Yang, Ying; McCrudden, John; Naire, Shailesh; Grunwald, Iris; Roffe, Christine

    2016-09-01

    Mechanical thrombectomy with stent retriever devices is associated with significantly better outcomes than thrombolysis alone in the treatment of acute ischemic stroke. Thrombus aspiration achieves high patency rates, but clinical outcomes are variable. The aim of this study was to examine the effect of different suction conditions on perfusate flow during aspiration thrombectomy. A computational fluid dynamics model of an aspiration device within a patent and occluded blood vessel was used to simulate flow characteristics using fluid flow solver software. A physical particulate flow model of a patent vessel and a vessel occluded by thrombus was then used to visualize flow direction and measure flow rates with the aspiration catheter placed 1-10 mm proximal of the thrombus, and recorded on video. The mathematical model predicted that, in a patent vessel, perfusate is drawn from upstream of the catheter tip while, in an occluded system, perfusate is drawn from the vessel proximal to the device tip with no traction on the occlusion distal of the tip. The in vitro experiments confirmed the predictions of this model. In the occluded vessel aspiration had no effect on the thrombus unless the tip of the catheter was in direct contact with the thrombus. These experiments suggest that aspiration is only effective if the catheter tip is in direct contact with the thrombus. If the catheter tip is not in contact with the thrombus, aspirate is drawn from the vessels proximal of the occlusion. This could affect collateral flow in vivo. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Probe tip heating assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmitz, Roger William; Oh, Yunje

    A heating assembly configured for use in mechanical testing at a scale of microns or less. The heating assembly includes a probe tip assembly configured for coupling with a transducer of the mechanical testing system. The probe tip assembly includes a probe tip heater system having a heating element, a probe tip coupled with the probe tip heater system, and a heater socket assembly. The heater socket assembly, in one example, includes a yoke and a heater interface that form a socket within the heater socket assembly. The probe tip heater system, coupled with the probe tip, is slidably receivedmore » and clamped within the socket.« less

  6. Identifying tips for intramolecular NC-AFM imaging via in situ fingerprinting

    NASA Astrophysics Data System (ADS)

    Sang, Hongqian; Jarvis, Samuel P.; Zhou, Zhichao; Sharp, Peter; Moriarty, Philip; Wang, Jianbo; Wang, Yu; Kantorovich, Lev

    2014-10-01

    A practical experimental strategy is proposed that could potentially enable greater control of the tip apex in non-contact atomic force microscopy experiments. It is based on a preparation of a structure of interest alongside a reference surface reconstruction on the same sample. Our proposed strategy is as follows. Spectroscopy measurements are first performed on the reference surface to identify the tip apex structure using a previously collected database of responses of different tips to this surface. Next, immediately following the tip identification protocol, the surface of interest is studied (imaging, manipulation and/or spectroscopy). The prototype system we choose is the mixed Si(111)-7×7 and surface which can be prepared on the same sample with a controlled ratio of reactive and passivated regions. Using an ``in silico'' approach based on ab initio density functional calculations and a set of tips with varying chemical reactivities, we show how one can perform tip fingerprinting using the Si(111)-7×7 reference surface. Then it is found by examining the imaging of a naphthalene tetracarboxylic diimide (NTCDI) molecule adsorbed on surface that negatively charged tips produce the best intramolecular contrast attributed to the enhancement of repulsive interactions.

  7. Method of preparing sodalite from chloride salt occluded zeolite

    DOEpatents

    Lewis, Michele A.; Pereira, Candido

    1997-01-01

    A method for immobilizing waste chloride salts containing radionuclides and hazardous nuclear material for permanent disposal starting with a substantially dry zeolite and sufficient glass to form leach resistant sodalite with occluded radionuclides and hazardous nuclear material. The zeolite and glass are heated to a temperature up to about 1000.degree. K. to convert the zeolite to sodalite and thereafter maintained at a pressure and temperature sufficient to form a sodalite product near theoretical density. Pressure is used on the formed sodalite to produce the required density.

  8. An Infectious Pseudoaneurysm Caused by Ventricular Septal Defect Occluder in Patent Ductus Arteriosus Closure in a Two-Year-Old Child.

    PubMed

    Li, Dingyang; Qiu, Qiu; Jin, Jing; Zhang, Changdong; Wang, Lijun; Zhang, Gangcheng

    2017-12-12

    We present a case of an infectious pseudoaneurysm after patent ductus arteriosus (PDA) closure with a ventricular septal defect (VSD) occluder in a two-year-old child. The aneurysm grew rapidly but was successfully removed in time and the patient survived. To our knowledge, this is the first report of an infectious pseudoaneurysm caused by VSD occluder in PDA closure.

  9. Effect of tip flange on tip leakage flow of small axial flow fans

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Jin, Yingzi; Jin, Yuzhen

    2014-02-01

    Aerodynamic performance of an axial flow fan is closely related to its tip clearance leakage flow. In this paper, the hot-wire anemometer is used to measure the three dimensional mean velocity near the blade tips. Moreover, the filtered N-S equations with finite volume method and RNG k-ɛ turbulence model are adopted to carry out the steady simulation calculation of several fans that differ only in tip flange shape and number. The large eddy simulation and the FW-H noise models are adopted to carry out the unsteady numerical calculation and aerodynamic noise prediction. The results of simulation calculation agree roughly with that of tests, which proves the numerical calculation method is feasible.The effects of tip flange shapes and numbers on the blade tip vortex structure and the characteristics are analyzed. The results show that tip flange of the fan has a certain influence on the characteristics of the fan. The maximum efficiencies for the fans with tip flanges are shifted towards partial flow with respect to the design point of the datum fan. Furthermore, the noise characteristics for the fans with tip flanges have become more deteriorated than that for the datum fan. Tip flange contributes to forming tip vortex shedding and the effect of the half-cylinder tip flange on tip vortex shedding is obvious. There is a distinct relationship between the characteristics of the fan and tip vortex shedding. The research results provide the profitable reference for the internal flow mechanism of the performance optimization of small axial flow fans.

  10. Reduced Performance of Prey Targeting in Pit Vipers with Contralaterally Occluded Infrared and Visual Senses

    PubMed Central

    Chen, Qin; Deng, Huanhuan; Brauth, Steven E.; Ding, Li; Tang, Yezhong

    2012-01-01

    Both visual and infrared (IR) senses are utilized in prey targeting by pit vipers. Visual and IR inputs project to the contralateral optic tectum where they activate both multimodal and bimodal neurons. A series of ocular and pit organ occlusion experiments using the short-tailed pit viper (Gloydius brevicaudus) were conducted to investigate the role of visual and IR information during prey targeting. Compared with unoccluded controls, snakes with either both eyes or pit organs occluded performed more poorly in hunting prey although such subjects still captured prey on 75% of trials. Subjects with one eye and one pit occluded on the same side of the face performed as well as those with bilateral occlusion although these subjects showed a significant targeting angle bias toward the unoccluded side. Performance was significantly poorer when only a single eye or pit was available. Interestingly, when one eye and one pit organ were occluded on opposite sides of the face, performance was poorest, the snakes striking prey on no more than half the trials. These results indicate that, visual and infrared information are both effective in prey targeting in this species, although interference between the two modalities occurs if visual and IR information is restricted to opposite sides of the brain. PMID:22606229

  11. Thulium fiber laser lithotripsy using a muzzle brake fiber tip

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-02-01

    The Thulium fiber laser (TFL) is being explored as an alternative to Holmium:YAG laser for lithotripsy. TFL beam profile allows coupling of higher power into smaller fibers than multimode Holmium laser beam, without proximal fiber tip degradation. A smaller fiber provides more space in ureteroscope working channel for increased saline irrigation and allows maximum ureteroscope flexion. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback, but increased retropulsion. In this study, a "fiber muzzle brake" was tested for reducing fiber burnback and stone retropulsion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-OD, 360-μm-ID tube with 275-μm thru hole located 250-μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed, ex vivo. Small stones with a mass of 40 +/- 4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25 +/- 4 s (n=10), without distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers. The muzzle brake fiber tip provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  12. Method of preparing sodalite from chloride salt occluded zeolite

    DOEpatents

    Lewis, M.A.; Pereira, C.

    1997-03-18

    A method is described for immobilizing waste chloride salts containing radionuclides and hazardous nuclear material for permanent disposal starting with a substantially dry zeolite and sufficient glass to form leach resistant sodalite with occluded radionuclides and hazardous nuclear material. The zeolite and glass are heated to a temperature up to about 1000 K to convert the zeolite to sodalite and thereafter maintained at a pressure and temperature sufficient to form a sodalite product near theoretical density. Pressure is used on the formed sodalite to produce the required density.

  13. Rotating coherent flow structures as a source for narrowband tip clearance noise from axial fans

    NASA Astrophysics Data System (ADS)

    Zhu, Tao; Lallier-Daniels, Dominic; Sanjosé, Marlène; Moreau, Stéphane; Carolus, Thomas

    2018-03-01

    Noise from axial fans typically increases significantly as the tip clearance is increased. In addition to the broadband tip clearance noise at the design flow rate, narrowband humps also associated with the tip flow are observed in the far-field acoustic spectra at lower flow rate. In this study, both experimental and numerical methods are used to shed more light on the noise generation mechanism of this narrowband tip clearance noise and provide a unified description of this source. Unsteady aeroacoustic predictions with the Lattice-Boltzmann Method (LBM) are successfully compared with experiment. Such a validation allows using LBM data to conduct a detailed modal analysis of the pressure field for detecting rotating coherent flow structures which might be considered as noise sources. As previously found in ring fans the narrowband humps in the far-field noise spectra are found to be related to the tip clearance noise that is generated by an interaction of coherent flow structures present in the tip region with the leading edge of the impeller blades. The visualization of the coherent structures shows that they are indeed part of the unsteady tip clearance vortex structures. They are hidden in a complex, spatially and temporally inhomogeneous flow field, but can be recovered by means of appropriate filtering techniques. Their pressure trace corresponds to the so-called rotational instability identified in previous turbomachinery studies, which brings a unified picture of this tip-noise phenomenon for the first time.

  14. Arctic climate tipping points.

    PubMed

    Lenton, Timothy M

    2012-02-01

    There is widespread concern that anthropogenic global warming will trigger Arctic climate tipping points. The Arctic has a long history of natural, abrupt climate changes, which together with current observations and model projections, can help us to identify which parts of the Arctic climate system might pass future tipping points. Here the climate tipping points are defined, noting that not all of them involve bifurcations leading to irreversible change. Past abrupt climate changes in the Arctic are briefly reviewed. Then, the current behaviour of a range of Arctic systems is summarised. Looking ahead, a range of potential tipping phenomena are described. This leads to a revised and expanded list of potential Arctic climate tipping elements, whose likelihood is assessed, in terms of how much warming will be required to tip them. Finally, the available responses are considered, especially the prospects for avoiding Arctic climate tipping points.

  15. [Over projected tip].

    PubMed

    Duron, J-B; Nguyen, P S; Levet, Y; Bardot, J; Aiach, G

    2014-12-01

    Overprojected tip is a pretty usual request not easy to manage. Preop analysis is crucial in order to evaluate tip support and skin thickness and ability to retract. For example, if the skin is very thick and has poor chance to retract, the surgeon should be very careful in the tip projection decreasing to avoid a skin pollybeak deformity. In such cases, he has to analyze the facial proportions, especially other areas projection (radix, dorsum and chin) and think about augmenting them to balance the profile rather than decreasing tip projection. Correction should always be conducted incrementally, starting with weakening the tip support mechanisms and, only if necessary, continue with alar cartilage interruption. This can be performed on many areas (lateral cruras, domes, medial cruras) and with several techniques (resection or interruption+overlapping). Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Indocyanine green videoangiography (ICGV)-guided surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS).

    PubMed

    d'Avella, Elena; Volpin, Francesco; Manara, Renzo; Scienza, Renato; Della Puppa, Alessandro

    2013-03-01

    Maximal safe resection is the goal of correct surgical treatment of parasagittal meningiomas, and it is intimately related to the venous anatomy both near and directly involved by the tumor. Indocyanine green videoangiography (ICGV) has already been advocated as an intra-operative resourceful technique in brain tumor surgery for the identification of vessels. The aim of this study was to investigate the role of ICGV in surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS). In this study, we prospectively analyzed clinical, radiological and intra-operative findings of patients affected by parasagittal meningioma occluding the SSS, who underwent ICGV assisted-surgery. Radiological diagnosis of complete SSS occlusion was pre-operatively established in all cases. ICGV was performed before dural opening, before and during tumor resection, at the end of the procedure. Five patients were included in our study. In all cases, ICGV guided dural opening, tumor resection, and venous management. The venous collateral pathway was easily identified and preserved in all cases. Radical resection was achieved in four cases. Surgery was uneventful in all cases. Despite the small number of patients, our study shows that ICG videoangiography could play a crucial role in guiding surgery of parasagittal meningioma occluding the SSS. Further studies are needed to define the role of this technique on functional and oncological outcome of these patients.

  17. Tipping news in information accumulation system

    NASA Astrophysics Data System (ADS)

    Shin, J. K.

    2010-05-01

    As a continuous opinion dynamics model, the information accumulation system (IAS) includes three basic mechanisms of the news, the inheritance and the diffusion as contributing to the information accumulation process of a system. A system is composed of agents who diffuse information through internal interaction, while each of them has incomplete memory or inheritance rate. The news comes from external sources of information, such as mass media. Previously the model IAS was studied only for the small news problems. In this study, a tipping news problem is considered. A key question of the problem is: what is the minimum strength of advertisement that can tip the minority opinion to a majority one? Dynamics of the IAS is briefly revisited with a special interest on nonlinear behavior of the model. In particular, it is shown that a discrete map of the IAS for a single color problem can be transformed into a logistic map, from which the dynamics of the IAS can be better understood. To show the applicability of the IAS model, the result is applied to explain the concept of the critical population size, which claims that there is a minimum population size for a social knowledge system to be continuously inherited without being lost. And critical size of the tipping news is found analytically in terms of IAS parameters. Some of the key results from the present study are compared in detail with the results from the Brownian particle model, which is believed to be the most similar model to the IAS. The concept of tipping news is used to show that a traditional society can tip at an exceptionally low inter-community exposure. Finally, the result was applied to the language competition problem.

  18. Physcomitrella patens: a model for tip cell growth and differentiation.

    PubMed

    Vidali, Luis; Bezanilla, Magdalena

    2012-12-01

    The moss Physcomitrella patens has emerged as an excellent model system owing to its amenability to reverse genetics. The moss gametophyte has three filamentous tissues that grow by tip growth: chloronemata, caulonemata, and rhizoids. Because establishment of the moss plant relies on this form of growth, it is particularly suited for dissecting the molecular basis of tip growth. Recent studies demonstrate that a core set of actin cytoskeletal proteins is essential for tip growth. Additional actin cytoskeletal components are required for modulating growth to produce caulonemata and rhizoids. Differentiation into these cell types has previously been linked to auxin, light and nutrients. Recent studies have identified that core auxin signaling components as well as transcription factors that respond to auxin or nutrient levels are required for tip-growing cell differentiation. Future studies may establish a connection between the actin cytoskeleton and auxin or nutrient-induced cell differentiation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Management of a large atrial septal occluder embolized to the left ventricular outflow tract without the use of cardiac surgery.

    PubMed

    Loh, Joshua P; Satler, Lowell F; Slack, Michael C

    2014-09-01

    Transcatheter closure of secundum-type atrial septal defects (ASDs) using the AMPLATZER™ Septal Occluder (ASO) has been in use for more than a decade since its US Food and Drug Administration approval in 2001. Device embolization remains an uncommon complication, which can sometimes occur after the initial deployment. Previous reports of ASO devices embolized to the left ventricle have primarily been managed by open-heart surgical retrieval. We present a case of an ASO device embolized to the left ventricular outflow tract (LVOT) 18 hr after initial implantation, which was successfully retrieved percutaneously, followed by successful closure of the ASD using a larger device. © 2014 Wiley Periodicals, Inc.

  20. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping.

    PubMed

    Clifton, Sara M; Herbers, Eileen; Chen, Jack; Abrams, Daniel M

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  1. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping

    NASA Astrophysics Data System (ADS)

    Clifton, Sara M.; Herbers, Eileen; Chen, Jack; Abrams, Daniel M.

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  2. Application of two-dimensional unsteady aerodynamic to a free-tip rotor response analysis

    NASA Technical Reports Server (NTRS)

    Yates, L.; Kumagai, H.

    1985-01-01

    The free-tip rotor utilizes a rotor blade tip which is structurally decoupled from the blade inboard section. The tip is free to pitch about its own pitch axis to respond to the local flow angularity changes. The tip also experiences the heaving motion due to the flapping of the rotor blade. For an airfoil in any pitching and heaving motion which can be expanded into a Fourier series, the lift and moment calculated by Theodoren's theory is simply the linear combination of the lift and moment calculated for each harmonic. These lift and moment are then used to determine the response of the free-tip rotor. A parametric study is performed to determine the effect of mechanical damping, mechanical spring, sweep, friction, and a constant control moment on the free-tip rotor response characteristics and the resulting azimuthal lift distributions. The results showed that the free-tip has the capability to suppress the oscillatory lift distribution around the azimuth and to eliminate a significant negative life peak on the advancing tip. This result agrees with the result of the previous analysis based on the steady aerodynamics.

  3. Tips for giving a memorable presentation Part V: stage fright and rehearsing a presentation.

    PubMed

    Harolds, Jay A

    2012-11-01

    Previous articles in this series have included many tips on composing a memorable presentation. This article will focus on rehearsing the presentation and dealing with stage fright. There are additional comments on making sure everything is optimized in the lecture room in advance and other tips for the actual presentation.

  4. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    NASA Technical Reports Server (NTRS)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  5. Septic Complication After Balloon-Occluded Retrograde Transvenous Obliteration of Duodenal Variceal Bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akasaka, Thai; Shibata, Toshiya, E-mail: ksj@kuhp.kyoto-u.ac.jp; Isoda, Hiroyoshi

    2010-12-15

    We report a 64-year-old woman with duodenal varices who underwent balloon-occluded retrograde transvenous obliteration (B-RTO) complicated by intraprocedural variceal rupture. The patient developed shivering and a fever higher than 40{sup o}C 3 days after the B-RTO procedure. A blood culture grew Entereobacter cloacoe. This case represents a rare septic complication of B-RTO for duodenal varices.

  6. Alar setback technique: a controlled method of nasal tip deprojection.

    PubMed

    Foda, H M

    2001-11-01

    To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires

  7. Technology Tips

    ERIC Educational Resources Information Center

    Mathematics Teacher, 2004

    2004-01-01

    Some inexpensive or free ways that enable to capture and use images in work are mentioned. The first tip demonstrates the methods of using some of the built-in capabilities of the Macintosh and Windows-based PC operating systems, and the second tip describes methods to capture and create images using SnagIt.

  8. Tip Vortex and Wake Characteristics of a Counterrotating Open Rotor

    NASA Technical Reports Server (NTRS)

    VanZante, Dale E.; Wernet, Mark P.

    2012-01-01

    One of the primary noise sources for Open Rotor systems is the interaction of the forward rotor tip vortex and blade wake with the aft rotor. NASA has collaborated with General Electric on the testing of a new generation of low noise, counterrotating Open Rotor systems. Three-dimensional particle image velocimetry measurements were acquired in the intra-rotor gap of the Historical Baseline blade set. The velocity measurements are of sufficient resolution to characterize the tip vortex size and trajectory as well as the rotor wake decay and turbulence character. The tip clearance vortex trajectory is compared to results from previously developed models. Forward rotor wake velocity profiles are shown. Results are presented in a form as to assist numerical modeling of Open Rotor system aerodynamics and acoustics.

  9. Tip-enhanced Raman scattering microscopy: Recent advance in tip production

    NASA Astrophysics Data System (ADS)

    Fujita, Yasuhiko; Walke, Peter; De Feyter, Steven; Uji-i, Hiroshi

    2016-08-01

    Tip-enhanced Raman scattering (TERS) microscopy is a technique that combines the chemical sensitivity of Raman spectroscopy with the resolving power of scanning probe microscopy. The key component of any TERS setup is a plasmonically-active noble metal tip, which serves to couple far-field incident radiation with the near-field. Thus, the design and implementation of reproducible probes are crucial for the continued development of TERS as a tool for nanoscopic analysis. Here we discuss conventional methods for the fabrication of TERS-ready tips, highlighting the problems therein, as well as detailing more recent developments to improve reducibility. In addition, the idea of remote excitation-TERS is enlightened upon, whereby TERS sensitivity is further improved by using propagating surface plasmons to separate the incident radiation from the tip apex, as well as how this can be incorporated into the fabrication process.

  10. Effect of non-Newtonian characteristics of blood on magnetic particle capture in occluded blood vessel

    NASA Astrophysics Data System (ADS)

    Bose, Sayan; Banerjee, Moloy

    2015-01-01

    Magnetic nanoparticles drug carriers continue to attract considerable interest for drug targeting in the treatment of cancer and other pathological conditions. Magnetic carrier particles with surface-bound drug molecules are injected into the vascular system upstream from the desired target site, and are captured at the target site via a local applied magnetic field. Herein, a numerical investigation of steady magnetic drug targeting (MDT) using functionalized magnetic micro-spheres in partly occluded blood vessel having a 90° bent is presented considering the effects of non-Newtonian characteristics of blood. An Eulerian-Lagrangian technique is adopted to resolve the hemodynamic flow and the motion of the magnetic particles in the flow using ANSYS FLUENT. An implantable infinitely long cylindrical current carrying conductor is used to create the requisite magnetic field. Targeted transport of the magnetic particles in a partly occluded vessel differs distinctly from the same in a regular unblocked vessel. Parametric investigation is conducted and the influence of the insert configuration and its position from the central plane of the artery (zoffset), particle size (dp) and its magnetic property (χ) and the magnitude of current (I) on the "capture efficiency" (CE) is reported. Analysis shows that there exists an optimum regime of operating parameters for which deposition of the drug carrying magnetic particles in a target zone on the partly occluded vessel wall can be maximized. The results provide useful design bases for in vitro set up for the investigation of MDT in stenosed blood vessels.

  11. [Percutaneous closure of ductus arteriosus and muscular ventricular defect with amplatzer occluder in a patient with severe pulmonary hypertension].

    PubMed

    García-Montes, José Antonio; Zabal Cerdeira, Carlos; Calderón-Colmenero, Juan; Espínola, Nilda; Fernández de la Reguera, Guillermo; Buendía Hernández, Alfonso

    2005-01-01

    Surgical treatment of multiple muscular ventricular septal defects with associated lesions and severe pulmonary hypertension has a high morbility and mortality. Closure of these defects by the Amplatzer muscular VSD occluder is an alternative to surgery, avoiding the need of cardiopulmonary bypass. We present the case of a 38 year-old woman with signs of heart failure in NYHA functional class IV, with two muscular ventricular septal defects, patent ductus arteriosus and severe pulmonary hypertension, that were treated with three Amplatzer muscular VSD occluders, with significant reduction of pulmonary pressure and functional class improvement.

  12. The localization of occluded matrix proteins in calcareous spicules of sea urchin larvae.

    PubMed

    Seto, Jong; Zhang, Yang; Hamilton, Patricia; Wilt, Fred

    2004-10-01

    The sea urchin embryo forms calcareous endoskeletal spicules composed of calcite and an occluded protein matrix. Though the latter is approximately 0.1% of of the mass, the composite has substantially altered material properties, e.g., conchoidal fracture planes and increased hardness. Experiments were conducted to examine the localization of matrix proteins occluded in the mineral by use of immunocytochemistry coupled with scanning electron microscopy (SEM). The isolated, unfixed spicules were etched under relatively gentle conditions and exposed to affinity purified antibodies made against two different matrix proteins, as well as an antibody to the entire constellation of matrix proteins. Immunogold tagged secondary antibody was used to observe antibody localization in the back scatter mode of SEM. All proteins examined were very widely distributed throughout the calcite, supporting a model of the structure in which a multiprotein assemblage is woven with fine texture around microcrystalline domains of calcite. Gentle etching revealed a laminar arrangement of calcite solubility, consistent with a stepwise deposition of matrix and mineral to increase girth of the spicule.

  13. Is It Worthwhile Treating Occluded Cold Stored Venous Allografts by Thrombolysis?

    PubMed

    Balaz, P; Wohlfahrt, P; Rokosny, S; Maly, S; Bjorck, M

    2016-09-01

    Thrombolysis has been reported to be suboptimal in occluded vein grafts and cryopreserved allografts, and there are no data on the efficacy of thrombolysis in occluded cold stored venous allografts. The aim was to evaluate early outcomes, secondary patency and limb salvage rates of thrombolysed cold stored venous allograft bypasses and to compare the outcomes with thrombolysis of autologous bypasses. This was a single center study of consecutive patients with acute and non-acute limb ischemia between September 1, 2000, and January 1, 2014, with occlusion of cold stored venous allografts, and between January 1, 2012, and January 1, 2014, with occlusion of autologous bypass who received intra-arterial thrombolytic therapy. Sixty-one patients with occlusion of an infrainguinal bypass using a cold stored venous allograft (n = 35) or an autologous bypass (n = 26) underwent percutaneous intra-arterial thrombolytic therapy. The median duration of thrombolysis was 20 h (IQR 18-24) with no difference between the groups (p = .14). The median follow up was 18.5 months (IQR 11.0-52.0). Secondary patency rates of thrombolysed bypass at 6 and 12 months were 44 ± 9% and 32 ± 9% in patients with a venous allograft bypass and 46 ± 10% and 22 ± 8% with an autologous bypass, with no difference between groups (p = .40). Limb salvage rates at 1, 6, and 12 months after thrombolysis in the venous allograft group were 83 ± 7%, 72 ± 8% and 63 ± 9%, and in the autologous group 91 ± 6%, 76 ± 9%, and 65 ± 13%, with no difference between groups (p = .69). Long-term results of thrombolysis of venous allograft bypasses are similar to those of autologous bypasses. Occluded cold stored venous allograft can be successfully re-opened in most cases with a favorable effect on limb salvage. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  14. HIV-1 Tat targets Tip60 to impair the apoptotic cell response to genotoxic stresses

    PubMed Central

    Col, Edwige; Caron, Cécile; Chable-Bessia, Christine; Legube, Gaelle; Gazzeri, Sylvie; Komatsu, Yasuhiko; Yoshida, Minoru; Benkirane, Monsef; Trouche, Didier; Khochbin, Saadi

    2005-01-01

    HIV-1 transactivator Tat uses cellular acetylation signalling by targeting several cellular histone acetyltransferases (HAT) to optimize its various functions. Although Tip60 was the first HAT identified to interact with Tat, the biological significance of this interaction has remained obscure. We had previously shown that Tat represses Tip60 HAT activity. Here, a new mechanism of Tip60 neutralization by Tat is described, where Tip60 is identified as a substrate for the newly reported p300/CBP-associated E4-type ubiquitin-ligase activity, and Tat uses this mechanism to induce the polyubiquitination and degradation of Tip60. Tip60 targeting by Tat results in a dramatic impairment of the Tip60-dependent apoptotic cell response to DNA damage. These data reveal yet unknown strategies developed by HIV-1 to increase cell resistance to genotoxic stresses and show a role of Tat as a modulator of cellular protein ubiquitination. PMID:16001085

  15. Factors Affecting Infants’ Manual Search for Occluded Objects and the Genesis of Object Permanence

    PubMed Central

    Moore, M. Keith; Meltzoff, Andrew N.

    2009-01-01

    Two experiments systematically examined factors that influence infants’ manual search for hidden objects (N = 96). Experiment 1 used a new procedure to assess infants’ search for partially versus totally occluded objects. Results showed that 8.75-month-old infants solved partial occlusions by removing the occluder and uncovering the object, but these same infants failed to use this skill on total occlusions. Experiment 2 used sound-producing objects to provide a perceptual clue to the objects’ hidden location. Sound clues significantly increased the success rate on total occlusions for 10-month-olds, but not for 8.75-month-olds. An identity development account is offered for why infants succeed on partial occlusions earlier than total occlusions and why sound helps only the older infants. We propose a mechanism for how infants use object identity as a basis for developing a notion of permanence. Implications are drawn for understanding the dissociation between looking-time and search assessments of object permanence. PMID:18036668

  16. Feasibility and safety of a new generation of gore septal occluder device in children.

    PubMed

    Lombardi, Maristella; Tagliente, Maria R; Pirolo, Teodoro; Massari, Elena; Milella, Leonardo; Vairo, Ugo

    2016-12-01

    Transcatheter closure of an ostium secundum atrial septal defect (ASD) is now considered the standard care for most of children with the appropriate anatomy, and is a relatively well-tolerated procedure to reduce the clinical sequelae of ASD, with a low complication rate. The present case reports describe our clinical experience of the percutaneous closure of a secundum ASD in 10 children between December 2011 and November 2012, by means of a new generation of device, the GORE Septal Occluder device. The implantation was successful in all except two cases, the device being properly placed and deployed without malposition or embolization in the catheterization laboratory. No complications were related to the procedure. The successful implant was confirmed and no major adverse events were documented in the following 3-12 months. The new GORE Septal Occluder device appears to be a feasible, well-tolerated and successful tool for the closure of an ASD of 15 mm or less in childhood.

  17. Factors affecting infants' manual search for occluded objects and the genesis of object permanence.

    PubMed

    Moore, M Keith; Meltzoff, Andrew N

    2008-04-01

    Two experiments systematically examined factors that influence infants' manual search for hidden objects (N=96). Experiment 1 used a new procedure to assess infants' search for partially versus totally occluded objects. Results showed that 8.75-month-old infants solved partial occlusions by removing the occluder and uncovering the object, but these same infants failed to use this skill on total occlusions. Experiment 2 used sound-producing objects to provide a perceptual clue to the objects' hidden location. Sound clues significantly increased the success rate on total occlusions for 10-month-olds, but not for 8.75-month-olds. An identity development account is offered for why infants succeed on partial occlusions earlier than total occlusions and why sound helps only the older infants. We propose a mechanism for how infants use object identity as a basis for developing a notion of permanence. Implications are drawn for understanding the dissociation between looking time and search assessments of object permanence.

  18. Investigation of tip clearance flow physics in axial flow turbine rotors

    NASA Astrophysics Data System (ADS)

    Xiao, Xinwen

    In axial turbines, the tip clearance between casing wall and rotating blades results in a tip leakage flow, which significantly affects loss production, heat protection, vibration and noise. It is important to minimize these effects for a better turbine engine performance and higher reliability. Most of previous efforts were concentrated on turbine cascades that however may not completely and correctly simulate the flow physics in practical turbine rotors. An investigation has to be performed in turbine rotors to reveal the real tip leakage flow physics in order to provide a scientific basis for minimizing its effects. This is the objective of this thesis research. The three dimensional flow field near the end wall/tip clearance region in a turbine rotor has been investigated experimentally, complemented by a numerical simulation to study the influences of inlet turbulence intensities on the development of the tip leakage flow. The experimental investigation is carried out in a modern unshrouded high pressure turbine stage. The survey region covers 20% span near the end wall, and extends axially from 10% chord upstream of the leading edge, through the rotor passage, and to 20% chord downstream of the trailing edge. It has been found that the tip leakage effects extend only to the surveyed region. The three dimensional LDV technique is used to measure the velocity and turbulence field upstream of the rotor, inside the rotor passage, and near the trailing edge. The static pressure on blade surfaces is surveyed from the rotating frame. The transient pressure on the casing wall is measured using a dynamic pressure sensor with a shaft encoder. A rotating Five Hole Probe is employed to measure the losses as well as the pressure and the three dimensional velocity field at 20% chord downstream of the rotor. The unsteady flow field is also investigated at this location by using a slanted single-element Hot Wire technique. The physics of the tip leakage flow and vortex in

  19. Cellular functions of TIP60.

    PubMed

    Sapountzi, Vasileia; Logan, Ian R; Robson, Craig N

    2006-01-01

    TIP60 was originally identified as a cellular acetyltransferase protein that interacts with HIV-1 Tat. As a consequence, the role of TIP60 in transcriptional regulation has been investigated intensively. Recent data suggest that TIP60 has more divergent functions than originally thought and roles for TIP60 in many processes, such as cellular signalling, DNA damage repair, cell cycle and checkpoint control and apoptosis are emerging. TIP60 is a tightly regulated transcriptional coregulator, acting in a large multiprotein complex for a range of transcription factors including androgen receptor, Myc, STAT3, NF-kappaB, E2F1 and p53. This usually involves recruitment of TIP60 acetyltransferase activities to chromatin. Additionally, in response to DNA double strand breaks, TIP60 is recruited to DNA lesions where it participates both in the initial as well as the final stages of repair. Here, we describe how TIP60 is a multifunctional enzyme involved in multiple nuclear transactions.

  20. A new coated nitinol occluder for transcatheter closure of ventricular septal defects in a canine model.

    PubMed

    Zhou, Yong; Chen, Feng; Huang, Xinmiao; Zhao, Xianxian; Wu, Hong; Bai, Yuan; Qin, Yongwen

    2013-01-01

    This study evaluated feasibility and safety of implanting the polyester-coated nitinol ventricular septal defect occluder (pcVSDO) in the canine model. VSD models were successfully established by transseptal ventricular septal puncture via the right jugular vein in 15 out of 18 canines. Two types of VSDOs were implanted, either with pcVSDOs (n = 8) as the new type occluder group or with the commercial ventricular septal defect occluders (VSDOs, n = 7, Shanghai Sharp Memory Alloy Co. Ltd.) as the control group. Sheath size was 10 French (10 Fr) in two groups. Then the general state of the canines was observed after implantation. ECG and TTE were performed, respectively, at 7, 30, 90 days of follow-up. The canines were sacrificed at these time points for pathological and scanning electron microscopy examination. The devices were successfully implanted in all 15 canines and were retrievable and repositionable. There was no thrombus formation on the device or occurrence of complete heart block. The pcVSDO surface implanted at day 7 was already covered with neotissue by gross examination, and it completed endothelialization at day 30, while the commercial VSDO was covered with the neotissue in 30th day and the complete endothelialization in 90th day. The study shows that pcVSDO is feasible and safe to close canine VSD model and has good biocompatibility and shorter time of endothelialization.

  1. A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws.

    PubMed

    Li, Shuang; Chang, Shi-Min; Jin, Yan-Min; Zhang, Ying-Qi; Niu, Wen-Xin; Du, Shou-Chao; Zhang, Li-Zhi; Ma, Hui

    2016-06-01

    As a predictor of the risk of lag screw cutout, it was recommended that keeping tip-apex distance (TAD)<25mm and placing the screw centrally or inferiorly, but positioning the lag screw too inferiorly in the head would produce TAD>25mm. We aim to simulate various positions of the lag screw in the femoral head and identify whether 25mm is a suitable cut-off value that favours all sizes of femoral heads with intertrochanteric fractures of the hip. Using a general mathematical software, the positions of the screw tip points were simulated. The virtual anterior-posterior and lateral views were then visualised, and the locus of the screw tips was projected into a Cartesian coordinate system according to the TAD and calcar-referenced tip-apex distance (CalTAD) formulas. Each original virtual anterior-posterior and lateral image was zoomed and compiled to match a calculated average image. The screw tip points were recorded, traced and compiled into volumes which could be used to visualise the screw's movements and positioning within the femoral head. The extracted volumes were calculated when 10mmtip were then assessed. For the TAD calculation, the shape of the traced screw tip points had a pancake-like appearance, while the CalTAD plot produced a teardrop-shaped region. The volume ratios of TAD, CalTAD and overlapping region relative to the femoral head volume were respectively 3.51±1.30%, 5.19±1.62% and 2.64±1.32%. The volumes of the traced TAD, CalTAD and overlapping regions increased slower than the volume of an idealised sphere. Positioning the lag screw should address geometrical effects of both tip-apex distance and femoral head size, with an emphasis on measuring the position of the screw tip for the suitable zone by volume ratio. The previous 25mm TAD cut-off value should be adjusted according to the individual femoral head

  2. Model-based occluded object recognition using Petri nets

    NASA Astrophysics Data System (ADS)

    Zhou, Chuan; Hura, Gurdeep S.

    1998-09-01

    This paper discusses the use of Petri nets to model the process of the object matching between an image and a model under different 2D geometric transformations. This transformation finds its applications in sensor-based robot control, flexible manufacturing system and industrial inspection, etc. A description approach for object structure is presented by its topological structure relation called Point-Line Relation Structure (PLRS). It has been shown how Petri nets can be used to model the matching process, and an optimal or near optimal matching can be obtained by tracking the reachability graph of the net. The experiment result shows that object can be successfully identified and located under 2D transformation such as translations, rotations, scale changes and distortions due to object occluded partially.

  3. A Randomized Controlled Trial of Two Semi-Occluded Vocal Tract Voice Therapy Protocols

    ERIC Educational Resources Information Center

    Kapsner-Smith, Mara R.; Hunter, Eric J.; Kirkham, Kimberly; Cox, Karin; Titze, Ingo R.

    2015-01-01

    Purpose: Although there is a long history of use of semi-occluded vocal tract gestures in voice therapy, including phonation through thin tubes or straws, the efficacy of phonation through tubes has not been established. This study compares results from a therapy program on the basis of phonation through a flow-resistant tube (FRT) with Vocal…

  4. Nano-Wilhelmy investigation of dynamic wetting properties of AFM tips through tip-nanobubble interaction

    PubMed Central

    Wang, Yuliang; Wang, Huimin; Bi, Shusheng; Guo, Bin

    2016-01-01

    The dynamic wetting properties of atomic force microscopy (AFM) tips are of much concern in many AFM-related measurement, fabrication, and manipulation applications. In this study, the wetting properties of silicon and silicon nitride AFM tips are investigated through dynamic contact angle measurement using a nano-Wilhelmy balance based method. This is done by capillary force measurement during extension and retraction motion of AFM tips relative to interfacial nanobubbles. The working principle of the proposed method and mathematic models for dynamic contact angle measurement are presented. Geometric models of AFM tips were constructed using scanning electronic microscopy (SEM) images taken from different view directions. The detailed process of tip-nanobubble interaction was investigated using force-distance curves of AFM on nanobubbles. Several parameters including nanobubble height, adhesion and capillary force between tip and nanobubbles are extracted. The variation of these parameters was studied over nanobubble surfaces. The dynamic contact angles of the AFM tips were calculated from the capillary force measurements. The proposed method provides direct measurement of dynamic contact angles for AFM tips and can also be taken as a general approach for nanoscale dynamic wetting property investigation. PMID:27452115

  5. Nano-Wilhelmy investigation of dynamic wetting properties of AFM tips through tip-nanobubble interaction

    NASA Astrophysics Data System (ADS)

    Wang, Yuliang; Wang, Huimin; Bi, Shusheng; Guo, Bin

    2016-07-01

    The dynamic wetting properties of atomic force microscopy (AFM) tips are of much concern in many AFM-related measurement, fabrication, and manipulation applications. In this study, the wetting properties of silicon and silicon nitride AFM tips are investigated through dynamic contact angle measurement using a nano-Wilhelmy balance based method. This is done by capillary force measurement during extension and retraction motion of AFM tips relative to interfacial nanobubbles. The working principle of the proposed method and mathematic models for dynamic contact angle measurement are presented. Geometric models of AFM tips were constructed using scanning electronic microscopy (SEM) images taken from different view directions. The detailed process of tip-nanobubble interaction was investigated using force-distance curves of AFM on nanobubbles. Several parameters including nanobubble height, adhesion and capillary force between tip and nanobubbles are extracted. The variation of these parameters was studied over nanobubble surfaces. The dynamic contact angles of the AFM tips were calculated from the capillary force measurements. The proposed method provides direct measurement of dynamic contact angles for AFM tips and can also be taken as a general approach for nanoscale dynamic wetting property investigation.

  6. Dissatisfaction with Nasal Tip Shape: Secondary Tip Maneuvers.

    PubMed

    Moyer, Jeffrey S

    2018-06-01

    Dissatisfaction with the appearance of the nasal tip is a common compliant in patients seeking revision surgery after rhinoplasty. Revision rhinoplasty is more technically difficult and unpredictable given the frequent presence of scar contracture, impaired skin envelope quality, and missing alar cartilage. This article describes some of the more common causes for tip revision surgery and techniques to address these abnormalities. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. 2.5-month-old infants' reasoning about when objects should and should not be occluded.

    PubMed

    Aguiar, A; Baillargeon, R

    1999-09-01

    The present research examined 2.5-month-old infants' reasoning about occlusion events. Three experiments investigated infants' ability to predict whether an object should remain continuously hidden or become temporarily visible when passing behind an occluder with an opening in its midsection. In Experiment 1, the infants were habituated to a short toy mouse that moved back and forth behind a screen. Next, the infants saw two test events that were identical to the habituation event except that a portion of the screen's midsection was removed to create a large window. In one event (high-window event), the window extended from the screen's upper edge; the mouse was shorter than the bottom of the window and thus did not become visible when passing behind the screen. In the other event (low-window event), the window extended from the screen's lower edge; although the mouse was shorter than the top of the window and hence should have become fully visible when passing behind the screen, it never appeared in the window. The infants tended to look equally at the high- and low-window events, suggesting that they were not surprised when the mouse failed to appear in the low window. However, positive results were obtained in Experiment 2 when the low-window event was modified: a portion of the screen above the window was removed so that the left and right sections of the screen were no longer connected (two-screens event). The infants looked reliably longer at the two-screens than at the high-window event. Together, the results of Experiments 1 and 2 suggested that, at 2.5 months of age, infants possess only very limited expectations about when objects should and should not be occluded. Specifically, infants expect objects (1) to become visible when passing between occluders and (2) to remain hidden when passing behind occluders, irrespective of whether these have openings extending from their upper or lower edges. Experiment 3 provided support for this interpretation. The

  8. Nanostar probes for tip-enhanced spectroscopy

    NASA Astrophysics Data System (ADS)

    Kim, Woong; Kim, Nara; Park, Joon Won; Kim, Zee Hwan

    2015-12-01

    To overcome the current limit of tip-enhanced spectroscopy that is based on metallic nano-probes, we developed a new scanning probe with a metallic nanostar, a nanoparticle with sharp spikes. A Au nanoparticle of 5 nm was first attached to the end of a tip through DNA-DNA hybridization and mechanical pick-up. The nanoparticle was converted to a nanostar with a core diameter of ~70 nm and spike lengths between 50 nm and 80 nm through the reduction of Au3+ with ascorbic acid in the presence of Ag+. Fabrication yields of such tips exceeded 60%, and more than 80% of such tips showed a mechanical durability sufficient for use in scanning microscopy. Effectiveness of the new probes for tip-enhanced Raman scattering (TERS) and tip-enhanced fluorescence (TEF) was confirmed. The probes exhibited the necessary enhancement for TEF, and the tip-on and tip-off ratios varied between 5 and 100. This large tip-to-tip variability may arise from the uncontrolled orientation of the apexes of the spike with respect to the sample surface, which calls for further fabrication improvement. The result overall supports a new fabrication approach for the probe that is effective for tip-enhanced spectroscopy.To overcome the current limit of tip-enhanced spectroscopy that is based on metallic nano-probes, we developed a new scanning probe with a metallic nanostar, a nanoparticle with sharp spikes. A Au nanoparticle of 5 nm was first attached to the end of a tip through DNA-DNA hybridization and mechanical pick-up. The nanoparticle was converted to a nanostar with a core diameter of ~70 nm and spike lengths between 50 nm and 80 nm through the reduction of Au3+ with ascorbic acid in the presence of Ag+. Fabrication yields of such tips exceeded 60%, and more than 80% of such tips showed a mechanical durability sufficient for use in scanning microscopy. Effectiveness of the new probes for tip-enhanced Raman scattering (TERS) and tip-enhanced fluorescence (TEF) was confirmed. The probes exhibited

  9. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    PubMed

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  10. Amplatzer angled duct occluder for closure of patent ductus arteriosus larger than the aorta in an infant.

    PubMed

    Vijayalakshmi, I B; Chitra, N; Rajasri, R; Prabhudeva, A N

    2005-01-01

    Transcatheter closure of patent ductus arteriosus (PDA) by Amplatzer duct occluder is the treatment of choice. However, closure of very large ducts in infants with low weight is a challenge for the interventionalist because a large device may obstruct the aorta or left pulmonary artery. Difficulty is also encountered in advancing the device around the curve of the right ventricular outflow tract toward the pulmonary artery; this curve is tight, more or less at a right angle in infants, leading to kinking of the sheath, which increases fluoroscopic time. This is the first reported case of a very large PDA (8.7 mm), larger than the aorta (8.2 mm), successfully closed by an Amplatzer angled duct occluder in an infant weighing 5 kg.

  11. Voice Training and Therapy with a Semi-Occluded Vocal Tract: Rationale and Scientific Underpinnings

    ERIC Educational Resources Information Center

    Titze, Ingo R.

    2006-01-01

    Purpose: Voice therapy with a semi-occluded vocal tract has a long history. The use of lip trills, tongue trills, bilabial fricatives, humming, and phonation into tubes or straws has been hailed by clinicians, singing teachers, and voice coaches as efficacious for training and rehabilitation. Little has been done, however, to provide the…

  12. Child Transportation Safety Tips.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This document presents nine tips regarding safe infant and child transportation, each tip explained in one to two pages. The tips are as follows: (1) quick safety seat checkup; (2) where should your child ride? (3) how to protect your new baby in the car; (4) what safety seat to use for a big baby or toddler? (5) how should preschool and school…

  13. Method to improve the blade tip-timing accuracy of fiber bundle sensor under varying tip clearance

    NASA Astrophysics Data System (ADS)

    Duan, Fajie; Zhang, Jilong; Jiang, Jiajia; Guo, Haotian; Ye, Dechao

    2016-01-01

    Blade vibration measurement based on the blade tip-timing method has become an industry-standard procedure. Fiber bundle sensors are widely used for tip-timing measurement. However, the variation of clearance between the sensor and the blade will bring a tip-timing error to fiber bundle sensors due to the change in signal amplitude. This article presents methods based on software and hardware to reduce the error caused by the tip clearance change. The software method utilizes both the rising and falling edges of the tip-timing signal to determine the blade arrival time, and a calibration process suitable for asymmetric tip-timing signals is presented. The hardware method uses an automatic gain control circuit to stabilize the signal amplitude. Experiments are conducted and the results prove that both methods can effectively reduce the impact of tip clearance variation on the blade tip-timing and improve the accuracy of measurements.

  14. A New Coated Nitinol Occluder for Transcatheter Closure of Ventricular Septal Defects in a Canine Model

    PubMed Central

    Zhou, Yong; Chen, Feng; Huang, Xinmiao; Zhao, Xianxian; Wu, Hong; Bai, Yuan; Qin, Yongwen

    2013-01-01

    Aims. This study evaluated feasibility and safety of implanting the polyester-coated nitinol ventricular septal defect occluder (pcVSDO) in the canine model. Methods and Results. VSD models were successfully established by transseptal ventricular septal puncture via the right jugular vein in 15 out of 18 canines. Two types of VSDOs were implanted, either with pcVSDOs (n = 8) as the new type occluder group or with the commercial ventricular septal defect occluders (VSDOs, n = 7, Shanghai Sharp Memory Alloy Co. Ltd.) as the control group. Sheath size was 10 French (10 Fr) in two groups. Then the general state of the canines was observed after implantation. ECG and TTE were performed, respectively, at 7, 30, 90 days of follow-up. The canines were sacrificed at these time points for pathological and scanning electron microscopy examination. The devices were successfully implanted in all 15 canines and were retrievable and repositionable. There was no thrombus formation on the device or occurrence of complete heart block. The pcVSDO surface implanted at day 7 was already covered with neotissue by gross examination, and it completed endothelialization at day 30, while the commercial VSDO was covered with the neotissue in 30th day and the complete endothelialization in 90th day. Conclusion. The study shows that pcVSDO is feasible and safe to close canine VSD model and has good biocompatibility and shorter time of endothelialization. PMID:24066289

  15. Dielectrophoretic positioning of single nanoparticles on atomic force microscope tips for tip-enhanced Raman spectroscopy.

    PubMed

    Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang

    2015-05-01

    Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Thulium fiber laser induced vapor bubbles using bare, tapered, ball, hollow steel, and muzzle brake fiber optic tips

    NASA Astrophysics Data System (ADS)

    Gonzalez, David A.; Hardy, Luke A.; Hutchens, Thomas C.; Irby, Pierce B.; Fried, Nathaniel M.

    2018-02-01

    This study characterizes laser-induced vapor bubbles for five distal fiber optic tip configurations, to provide insight into stone retropulsion experienced during laser ablation of kidney stones. A TFL with 1908-nm wavelength delivered 34 mJ energy per pulse at 500-μs pulse duration through five different fibers: 100-μm-core/170-μm-OD bare fiber tip, 150-μm- to 300-μm-core tapered fiber tip, 100-μm-core/300-μm-OD ball tip fiber, 100-μm-core/340- μm-OD hollow steel tip fiber, and 100-μm-core/560-μm-OD muzzle brake fiber tip. A high speed camera with 10- μm spatial and 9.5-μs temporal resolution imaged vapor bubble dynamics. A needle hydrophone measured pressure transients in forward (0°) and side (90°) directions while placed at a 6.8 +/- 0.4 mm distance from fiber tip. Maximum bubble dimensions (width/length) averaged 0.7/1.5, 1.0/1.6, 0.5/1.1, 0.8/1.9, and 0.7/1.5 mm, for bare, tapered, ball, hollow steel, and muzzle tips, respectively (n=5). The hollow steel tip exhibited the most elongated vapor bubble shape, translating into increased forward pressure in this study and consistent with higher stone retropulsion in previous reports. Relative pressures (a.u.) in (forward/side) directions averaged 1.7/1.6, 2.0/2.0, 1.4/1.2, 6.8/1.1, and 0.3/1.2, for each fiber tip (n=5). For hollow steel tip, forward pressure was 4× higher than for bare fiber. For the muzzle brake fiber tip, forward pressure was 5× lower than for bare fiber. Bubble dimensions and pressure measurements demonstrated that the muzzle tip reduced forward pressure by partially venting vapors through side holes, consistent with lower stone retropulsion observed in previous reports.

  17. Prom Health and Safety Tips

    MedlinePlus

    ... Halloween Prom Tips Spring Break Valentine Tips Winter Holiday Tips 12 Ways Holiday Song Healthy Living Check-Ups are Important Check- ... Test Wash Hands Stay Warm Have a Healthy Holiday Don’t Drink and Drive Widgets Healthy People ...

  18. Tip off the HAT– Epigenetic control of learning and memory by Drosophila Tip60

    PubMed Central

    Xu, Songjun; Elefant, Felice

    2015-01-01

    Disruption of epigenetic gene control mechanisms involving histone acetylation in the brain causes cognitive impairment, a debilitating hallmark of most neurodegenerative disorders. Histone acetylation regulates cognitive gene expression via chromatin packaging control in neurons. Unfortunately, the histone acetyltransferases (HATs) that generate such neural epigenetic signatures and their mechanisms of action remain unclear. Our recent findings provide insight into this question by demonstrating that Tip60 HAT action is critical for morphology and function of the mushroom body (MB), the learning and memory center in the Drosophila brain. We show that Tip60 is robustly produced in MB Kenyon cells and extending axonal lobes and that targeted MB Tip60 HAT loss results in axonal outgrowth disruption. Functional consequences of loss and gain of Tip60 HAT levels in the MB are evidenced by defects in memory. Tip60 ChIP-Seq analysis reveals enrichment for genes that function in cognitive processes and accordingly, key genes representing these pathways are misregulated in the Tip60 HAT mutant fly brain. Remarkably, increasing levels of Tip60 in the MB rescues learning and memory deficits resulting from Alzheimer's disease associated amyloid precursor protein (APP) induced neurodegeneration. Our studies highlight the potential of HAT activators as a therapeutic option for cognitive disorders. PMID:26327426

  19. Advanced turbine blade tip seal system

    NASA Technical Reports Server (NTRS)

    Zelahy, J. W.

    1981-01-01

    An advanced blade/shroud system designed to maintain close clearance between blade tips and turbine shrouds and at the same time, be resistant to environmental effects including high temperature oxidation, hot corrosion, and thermal cycling is described. Increased efficiency and increased blade life are attained by using the advanced blade tip seal system. Features of the system include improved clearance control when blade tips preferentially wear the shrouds and a superior single crystal superalloy tip. The tip design, joint location, characterization of the single crystal tip alloy, the abrasive tip treatment, and the component and engine test are among the factors addressed. Results of wear testing, quality control plans, and the total manufacturing cycle required to fully process the blades are also discussed.

  20. Total Telephone Tips.

    ERIC Educational Resources Information Center

    Corder, Lloyd E.; And Others

    This manual of telephone behavior tips for business and sales professionals offers ways to handle the disgruntled caller and makes suggestions on topics relevant to the telephone. The manual is divided into the following sections and subsections: (1) Common Courtesy (staff tips, answering the telephone, screening calls, transferring calls, taking…

  1. Scanning tip microwave near field microscope

    DOEpatents

    Xiang, Xiao-Dong; Schultz, Peter G.; Wei, Tao

    1998-01-01

    A microwave near field microscope has a novel microwave probe structure wherein the probing field of evanescent radiation is emitted from a sharpened metal tip instead of an aperture or gap. This sharpened tip, which is electrically and mechanically connected to a central electrode, extends through and beyond an aperture in an endwall of a microwave resonating device such as a microwave cavity resonator or a microwave stripline resonator. Since the field intensity at the tip increases as the tip sharpens, the total energy which is radiated from the tip and absorbed by the sample increases as the tip sharpens. The result is improved spatial resolution without sacrificing sensitivity.

  2. Experiments on tip vortices interacting with downstream wings

    NASA Astrophysics Data System (ADS)

    Chen, C.; Wang, Z.; Gursul, I.

    2018-05-01

    The interaction of meandering tip vortices shed from a leading wing with a downstream wing was investigated experimentally in a water tunnel using flow visualization, particle image velocimetry measurements, and volumetric velocity measurements. Counter-rotating upstream vortices may exhibit sudden variations of the vortex core location when the wing-tip separation is within approximately twice the vortex core radius. This is caused by the formation of vortex dipoles near the wing tip. In contrast, co-rotating upstream vortices do not exhibit such sensitivity. Large spanwise displacement of the trajectory due to the image vortex is possible when the incident vortex is further inboard. For both co-rotating and counter-rotating vortices, as long as there is no direct impingement upon the wing, there is a little change in the structure of the time-averaged vortex past the wing, even though the tip vortex shed from the downstream wing may be substantially weakened or strengthened. In the absence of the downstream wing, as well as for weak interactions, the most energetic unsteady modes represent the first helical mode | m| = 1, which is estimated from the three-dimensional Proper Orthogonal Decomposition modes and has a very large wavelength, on the order of 102 times the vortex core radius, λ/ a = O(102). Instantaneous vorticity measurements as well as flow visualization suggest the existence of a smaller wavelength, λ/ a = 5-6, which is not among the most energetic modes. These two-orders of magnitude different wavelengths are in agreement with the previous measurements of tip vortices and also exhibit qualitative agreement with the transient energy growth analysis. The very long wavelength mode in the upstream vortex may persist during the interaction, and reveal coupling with the trailing vortex as well as increased meandering.

  3. Thulium fiber laser-induced vapor bubble dynamics using bare, tapered, ball, hollow steel, and muzzle brake fiber optic tips

    NASA Astrophysics Data System (ADS)

    Gonzalez, David A.; Hardy, Luke A.; Hutchens, Thomas C.; Irby, Pierce B.; Fried, Nathaniel M.

    2018-03-01

    This study characterizes laser-induced vapor bubble dynamics for five different distal fiber optic tip configurations, to provide insight into stone retropulsion commonly experienced during laser ablation of kidney stones. A thulium fiber laser with 1908-nm wavelength delivered 34-mJ energy per pulse at 500-μs pulse duration through five different fibers such as 100-μm-core / 170-μm-OD bare fiber tip, 150- to 300-μm-core tapered fiber tip, 100-μm-core / 300-μm-OD ball tip fiber, 100-μm-core / 340-μm-OD hollow steel tip fiber, and 100-μm-core / 560-μm-OD muzzle brake fiber tip. A high-speed camera with 10-μm-spatial and 9.5-μs-temporal resolution was used to image the vapor bubble dynamics. A needle hydrophone measured pressure transients in the forward (0 deg) and side (90 deg) directions while placed at a 6.8 ± 0.4 mm distance from the distal fiber tip. Maximum bubble dimensions (width/length) averaged 0.7/1.5, 1.0/1.6, 0.5/1.1, 0.8/1.9, and 0.7 / 1.5 mm, for bare, tapered, ball, hollow steel, and muzzle brake fiber tips, respectively (n = 5). The hollow steel tip exhibited the most elongated vapor bubble shape, translating into increased forward pressure in this study and consistent with higher stone retropulsion in previous reports. Relative pressures (a.u.) in (forward/side) directions averaged 1.7/1.6, 2.0/2.0, 1.4/1.2, 6.8/1.1, and 0.3/1.2, for each fiber tip (n = 5). For the hollow steel tip, forward pressure was 4 × higher than for the bare fiber. For the muzzle brake fiber tip, forward pressure was 5 × lower than the bare fiber. Bubble dimensions and pressure measurements demonstrated that the muzzle brake fiber tip reduced forward pressure by partially venting vapors through the portholes, which is consistent with the observation of lower stone retropulsion in previous reports.

  4. Retrieval of large Occlutech Figula Flex septal defect occluders using a commercially available bioptome: proof of concept.

    PubMed

    Georgiev, Stanimir; Tanase, Daniel; Genz, Thomas; Ewert, Peter; Naumann, Susanne; Pozza, Robert Dalla; Eicken, Andreas

    2018-07-01

    This study aimed to develop a method for retrieval of the new meshed nitinol atrial septal defect occluders - Ceraflex and Occlutech. The newly developed atrial septal defect occluders have potential benefits considering implantation, but concerns regarding their removal in case of embolisation have been raised. Over 21 years, 1449 patients underwent interventional atrial septal defect occlusion in our institution. We reviewed the cases of embolisation of the device, developed a strategy for device removal, and tested it on the benchside and in animal tests. In 11 patients (0.8%), the intended atrial septal defect occlusion was complicated by an embolisation of the device. In contrast to the Amplatzer septal occluders, retrieval of Occlutech devices larger than 16 mm with snare techniques was impossible. In benchside tests, this was confirmed and a new method for removal of large meshed devices was developed. This involved the commercially available Maslanka® biopsy forceps. The feasibility of this technique in vivo was tested in a pig model. During animal tests, using the Maslanka biopsy forceps it was possible to interventionally retrieve embolised Ceraflex and Occlutech devices of different sizes - 10, 16, 30, and 40 mm - into a 12-F sheath. It was impossible to retrieve Occlutech and Ceraflex devices larger than 16 mm into a large sheath in vivo and during benchside tests. However, this was feasible on the bench and in vivo using the Maslanka biopsy forceps even with the largest available devices.

  5. Rhythmic neural activity indicates the contribution of attention and memory to the processing of occluded movements in 10-month-old infants.

    PubMed

    Bache, Cathleen; Kopp, Franziska; Springer, Anne; Stadler, Waltraud; Lindenberger, Ulman; Werkle-Bergner, Markus

    2015-11-01

    Infants possess the remarkable capacity to perceive occluded movements as ongoing and coherent. Little is known about the neural mechanisms that enable internal representation of conspecifics' and inanimate objects' movements during visual occlusion. In this study, 10-month-old infants watched briefly occluded human and object movements. Prior to occlusion, continuous and distorted versions of the movement were shown. EEG recordings were used to assess neural activity assumed to relate to processes of attention (occipital alpha), memory (frontal theta), and sensorimotor simulation (central alpha) before, during, and after occlusion. Oscillatory activity was analyzed using an individualized data approach taking idiosyncrasies into account. Results for occipital alpha were consistent with infants' preference for attending to social stimuli. Furthermore, frontal theta activity was more pronounced when tracking distorted as opposed to continuous movement, and when maintaining object as opposed to human movement. Central alpha did not discriminate between experimental conditions. In sum, we conclude that observing occluded movements recruits processes of attention and memory which are modulated by stimulus and movement properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Turbine blade with contoured chamfered squealer tip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ching-Pang

    2014-12-30

    A squealer tip formed from a pressure side tip wall and a suction side tip wall extending radially outward from a tip of the turbine blade is disclosed. The pressure and suction side tip walls may be positioned along the pressure sidewall and the suction sidewall of the turbine blade, respectively. The pressure side tip wall may include a chamfered leading edge with film cooling holes having exhaust outlets positioned therein. An axially extending tip wall may be formed from at least two outer linear surfaces joined together at an intersection forming a concave axially extending tip wall. The axiallymore » extending tip wall may include a convex inner surface forming a radially outer end to an inner cavity forming a cooling system. The cooling system may include one or more film cooling holes in the axially extending tip wall proximate to the suction sidewall, which promotes increased cooling at the pressure and suction sidewalls.« less

  7. Slender tip laser scalpel

    DOEpatents

    Veligdan, James T.

    2004-01-06

    A laser scalpel includes a ribbon optical waveguide extending therethrough and terminating at a slender optical cutting tip. A laser beam is emitted along the height of the cutting tip for cutting tissue therealong.

  8. Scanning tip microwave near field microscope

    DOEpatents

    Xiang, X.D.; Schultz, P.G.; Wei, T.

    1998-10-13

    A microwave near field microscope has a novel microwave probe structure wherein the probing field of evanescent radiation is emitted from a sharpened metal tip instead of an aperture or gap. This sharpened tip, which is electrically and mechanically connected to a central electrode, extends through and beyond an aperture in an end wall of a microwave resonating device such as a microwave cavity resonator or a microwave stripline resonator. Since the field intensity at the tip increases as the tip sharpens, the total energy which is radiated from the tip and absorbed by the sample increases as the tip sharpens. The result is improved spatial resolution without sacrificing sensitivity. 17 figs.

  9. In Vitro Ability of a Novel Nanohydroxyapatite Oral Rinse to Occlude Dentine Tubules

    PubMed Central

    Hill, Robert G.; Chen, Xiaohui; Gillam, David G.

    2015-01-01

    Objectives. The aim of the study was to investigate the ability of a novel nanohydroxyapatite (nHA) desensitizing oral rinse to occlude dentine tubules compared to selected commercially available desensitizing oral rinses. Methods. 25 caries-free extracted molars were sectioned into 1 mm thick dentine discs. The dentine discs (n = 25) were etched with 6% citric acid for 2 minutes and rinsed with distilled water, prior to a 30-second application of test and control oral rinses. Evaluation was by (1) Scanning Electron Microscopy (SEM) of the dentine surface and (2) fluid flow measurements through a dentine disc. Results. Most of the oral rinses failed to adequately cover the dentine surface apart from the nHa oral rinse. However the hydroxyapatite, 1.4% potassium oxalate, and arginine/PVM/MA copolymer oral rinses, appeared to be relatively more effective than the nHA test and negative control rinses (potassium nitrate) in relation to a reduction in fluid flow measurements. Conclusions. Although the novel nHA oral rinse demonstrated the ability to occlude the dentine tubules and reduce the fluid flow measurements, some of the other oral rinses appeared to demonstrate a statistically significant reduction in fluid flow through the dentine disc, in particular the arginine/PVM/MA copolymer oral rinse. PMID:26161093

  10. [Outcome of transcatheter closure of perimembranous ventricular septal defect with modified double-disk occluder device].

    PubMed

    Liu, Jing; You, Xiao-hua; Zhao, Xian-xian; Hu, Jian-qiang; Cao, Jiang; Xu, Rong-liang; Wu, Hong; Chen, Shao-ping; Zhang, Jian-liang; Zheng, Xing; Qin, Yong-wen

    2010-04-01

    To evaluate the efficacy and adverse effects of transcatheter closure of perimembranous ventricular septal defect (pmVSD) with modified double-disk occluder device (MDVO). Clinical data including clinical examination, electrocardiography daily after the procedure for a week, chest-X-rays and TTE before discharge and at 3-5 days after the procedure were analyzed from 604 patients underwent percutaneous closure of a pmVSD with MDVO at our department between December 2001 and December 2008. Procedure was successful in 576 out of 604 patients (95.4%) and 583 VSD occluders were placed. Endocarditis, thromboembolism, or deaths were not observed after procedure. Conduction block occurred in 81 patients (56 RBBB, 14 LBBB) and transient nonparoxysmal ventricular tachycardia in 31 patients after the procedure. Complete heart block occurred in 11 patients, 9 of them recovered in 3 weeks, permanent pacemaker was implanted in 2 patients (one had transient III degrees AVB before the procedure, the other underwent simultaneous closure of ventricular septal defect and atrial septal defect). Trivial/small residual shunts were found in 69 patients (12.0%). The residual shunts disappeared in 31 patients and remained unchanged in 38 patients (6.6%) 7 days after procedures. Aortic regurgitation developed in 5 patients (2 trivial/small, 3 small/moderate), and tricuspid regurgitation was present in 35 patients (32 trivial/small, 3 moderate). Five patients developed haemolysis (device retrieved via catheter in 1 patient due to persistent haemolysis, the other 4 patients recovered 3-14 days post procedure). Pseudoaneurysm of femoral artery occurred in 1 patient, and disappeared by pressure dressing. Device was successfully replaced in 2 patients with either device embolization (n = 1) or device misplacement (n = 1) after device retrieval by catheter. It is safe and effective to close congenital perimembranous ventricular septal defect with domestic-made occluder device.

  11. Reference system for scanning probe tip fingerprinting

    NASA Astrophysics Data System (ADS)

    Turansky, Robert; Bamidele, Joseph; Sugawara, Yasuhiro; Kantorovitch, Lev; Stich, Ivan

    2012-02-01

    Knowledge of the chemical structure of the tip asperity in Non-Contact Atomic Force Microscopy (NC-AFM) is crucial as controlled manipulation of atoms and/or molecules on surfaces can only be performed if this information is available. However, a simple and robust protocol for ensuring a specific tip termination has not yet been developed. We propose a procedure for chemical tip finger printing and an example of a reference system, the oxygen-terminated Cu(110) surface, that enables one to ensure a specific tip termination with Si, Cu, or O atoms. To follow this up and unambiguously determine tip types, we performed a theoretical DFT study of the line scans with the tip models in question and found that the tip characterization made based on experimental results (Cu/O-terminated tip imaging Cu/O atoms) is in fact incorrect and the opposite is true (Cu/O-terminated tip imaging O/Cu atoms). This protocol allows the tip asperity's chemical structure to be verified and established both before as well as at any stage of the manipulation experiment when numerous tip changes may take place.

  12. Is it necessary to occlude the ear in bone-conduction testing at 4 kHz, in order to prevent air-borne radiation affecting the results?

    PubMed

    Tate Maltby, Maryanne; Gaszczyk, David

    2015-01-01

    To re-evaluate the current BSA recommendation that the test ear should be occluded during the bone-conduction procedure at frequencies above 2 kHz to prevent audible air-borne radiation. Pure-tone audiometry was undertaken during routine hearing tests. The audiograms of fifty-two ears met the criteria for the study and were included. Bone conduction at 4 kHz was tested in three different conditions: test ear open/occluded by earplug and occluded by circumaural earphone. Forty-four adults aged 41-77 years with average hearing levels from normal to severe loss. All complied fully with the test procedure. No audiogram had a significant conductive element. There was no significant difference in each of the three test situations. Only two audiograms showed any (5 dB) difference at 4 kHz when bone conduction was retested with the ear occluded. The errors that result in a false air-bone gap at 4 kHz would not appear to be due to air-borne radiation. Failure to occlude the ear canal at 4 kHz, where air-borne radiation is greatest, makes no significant difference to the audiometric results. It is therefore suggested that it is unnecessary to block the test ear during routine pure-tone bone-conduction testing to prevent audible air-borne radiation, and that this should no longer form part of normal clinical practice.

  13. Levator alae nasi muscle V-Y island flap for nasal tip reconstruction.

    PubMed

    La Padula, Simone; Abbate, Vincenzo; Di Monta, Gianluca; Schonauer, Fabrizio

    2017-03-01

    Nasal tip reconstruction can be very challenging. It requires close attention to skin texture, colour and thickness matching, with the respect of the nasal aesthetic units and symmetry. Flaps are usually preferred to skin grafts where possible. Based on different donor areas, various flaps have been described for reconstruction of this region. Here we present a new V-Y myocutaneous island flap based on the levator alae nasi muscle (LAN muscle) blood supply. This flap may represent an alternative to the nasalis myocutaneous sliding V-Y flap previously described by Rybka. As its pivot point it is located more cranially than the nasalis flap, and it can advance more medially than the Rybka flap, with the possibility of covering larger defects of the nasal tip area, up to 1.8 cm in diameter. Over the past 5 years, 24 patients received nasal tip reconstruction with this flap following the resection of basal cell carcinomas. Good tip projection was maintained, and the aesthetic outcome was satisfactory, with well healed scars. We recommend this technique as an alternative to other flaps for nasal tip defects, especially if paramedian. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils.

    PubMed

    Celiker, Alpay; Aypar, Ebru; Karagöz, Tevfik; Dilber, Embiya; Ceviz, Naci

    2005-08-01

    The detachable coils have been successfully used for transcatheter occlusion of small- to moderate-sized patent ductus arteriosus (PDA). We report our experience regarding the use of the Nit-Occlud coils (NOCs) for transcatheter PDA and major aortopulmonary collateral (MAPCA) occlusion. Single NOCs were used to close PDA in 26 patients, and one small and two large MAPCAs in two patients. Mean age and weight of the patients were 7.7 +/- 5.4 years and 20.6 +/- 11.6 kg. Mean minimum duct diameter was 2.8 +/- 0.8 mm; ampulla, 8.7 +/- 2.4 mm; and PDA length, 9.3 +/- 4.4 mm. Mean pulmonary artery pressure ranged from 9 to 51 mm Hg and pulmonary/systemic flow ratio from 1.1 to 5.8. Ductal shape was conical in 24 patients. Route of approach was venous in 23 and arterial in 3. Successful coil implantation was achieved in 24/26 (92.3%). Mean procedure and fluoroscopy time were 67.2 +/- 22.1 and 14.9 +/- 6.5 min. The three MAPCAs were also successfully occluded using NOC Medium and Flex. Postimplantation angiograms revealed no leak in 3, a trace or small leak in 17, and a medium leak in 4 patients. Mean follow-up was 7 +/- 5 months. Complete occlusion was achieved in 17/24 (71%) at 24 hr, 19/24 (79%) by 1 month, 13/15 (87%) by 3 months, 14/15 (93%) by 6 months, and 10/11 (90%) by 12 months postprocedure. Hemolysis, late embolization, duct recanalization, and flow disturbances were not observed. Transcatheter occlusion of moderate-sized PDAs and MAPCAs using NOCs seems to offer a safe, simple, and controlled method in pediatric patients.

  15. Confirmatory Factor Analysis of the Trinity Inventory of Precursors to Suicide (TIPS) and Its Relationship to Hopelessness and Depression

    ERIC Educational Resources Information Center

    Smyth, Caroline L.; MacLachlan, Malcolm

    2005-01-01

    Numerous existing measures assess attitudes toward suicide yet fail to account for contextual factors. The Trinity Inventory of Precursors to Suicide (TIPS) is presented as an alternative, with implications for the development of prevention programs. Having previously reported exploratory analysis of the TIPS; confirmatory factor analysis and…

  16. ADHD: Tips to Try

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español ADHD: Tips to Try KidsHealth / For Teens / ADHD: Tips to Try Print en español TDAH: Consejos que puedes probar ADHD , short for attention deficit hyperactivity disorder , is a ...

  17. Intravascular US-Guided Portal Vein Access: Improved Procedural Metrics during TIPS Creation.

    PubMed

    Gipson, Matthew G; Smith, Mitchell T; Durham, Janette D; Brown, Anthony; Johnson, Thor; Ray, Charles E; Gupta, Rajan K; Kondo, Kimi L; Rochon, Paul J; Ryu, Robert K

    2016-08-01

    To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  18. Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

    PubMed Central

    Behjati-Ardakani, Mostafa; Behjati-Ardakani, Mohammad-Amin; Hosseini, Seyed-Habibolla; Noori, Noormohammad

    2013-01-01

    Objective Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). Methods From May 2004 to September 2011, forty eight infants underwent transcatheter closure of PDA. A lateral or right anterior oblique view aortogram was done to locate PDA and to measure its size. Before discharge, repeat aortogram was performed to evaluate eventual residual shunt and to confirm the appropriate deployment of the ADO. Follow up evaluations were done with transthoracic echocardiography at discharge, 1 month, 6 months, 12 months and yearly thereafter. Findings The mean age of patients at procedure was 9.18±2.32 (range 3 to 12) months, mean weight 6.73±1.16 (range 4.5 to 10.1) kg. The PDA occluded completely in 20 out of the 48 patients. Twenty four patients had trivial or mild shunt and two patients had moderate residual shunt which disappeared in one patient within 24 hours and other patient with moderate shunt in 1 month. One patient (age 8 months) had mild LPA stenosis. The device emobolization occurred in two patients, immediately after the procedure in one and during night in the other patient Conclusion The long term results suggested that transcatheter closure of PDA using Amplatzer duct occluder is a safe and effective treatment in infants less than 1 year of age with minimal complications. PMID:24427494

  19. A novel carbon tipped single micro-optrode for combined optogenetics and electrophysiology

    PubMed Central

    Vizvári, Attila D.; Bali, Zsolt K.; Márki, Balázs; Nagy, Lili V.; Kónya, Zoltán; Madarász, Dániel; Henn-Mike, Nóra; Varga, Csaba; Hernádi, István

    2018-01-01

    Optical microelectrodes (optrodes) are used in neuroscience to transmit light into the brain of a genetically modified animal to evoke and record electrical activity from light-sensitive neurons. Our novel micro-optrode solution integrates a light-transmitting 125 micrometer optical fiber and a 9 micrometer carbon monofilament to form an electrical lead element, which is contained in a borosilicate glass sheathing coaxial arrangement ending with a micrometer-sized carbon tip. This novel unit design is stiff and slender enough to be used for targeting deep brain areas, and may cause less tissue damage compared with previous models. The center-positioned carbon fiber is less prone to light-induced artifacts than side-lit metal microelectrodes previously presented. The carbon tip is capable of not only recording electrical signals of neuronal origin but can also provide valuable surface area for electron transfer, which is essential in electrochemical (voltammetry, amperometry) or microbiosensor applications. We present details of design and manufacture as well as operational examples of the newly developed single micro-optrode, which includes assessments of 1) carbon tip length–impedance relationship, 2) light transmission capabilities, 3) photoelectric artifacts in carbon fibers, 4) responses to dopamine using fast-scan cyclic voltammetry in vivo, and 5) optogenetic stimulation and spike or local field potential recording from the rat brain transfected with channelrhodopsin-2. With this work, we demonstrate that our novel carbon tipped single micro-optrode may open up new avenues for use in optogenetic stimulation when needing to be combined with extracellular recording, electrochemical, or microbiosensor measurements performed on a millisecond basis. PMID:29513711

  20. Effects of Double-Leakage Tip Clearance Flow on the Performance of a Compressor Stage with a Large Rotor Tip Gap

    NASA Technical Reports Server (NTRS)

    Hah, Chunill

    2016-01-01

    Effects of a large rotor tip gap on the performance of a one and half stage axial compressor are investigated in detail with a numerical simulation based on LES and available PIV data. The current paper studies the main flow physics, including why and how the loss generation is increased with the large rotor tip gap. The present study reveals that when the tip gap becomes large, tip clearance fluid goes over the tip clearance core vortex and enters into the next blade's tip gap, which is called double-leakage tip clearance flow. As the tip clearance flow enters into the adjacent blade's tip gap, a vortex rope with a lower pressure core is generated. This vortex rope breaks up the tip clearance core vortex of the adjacent blade, resulting in a large additional mixing. This double-leakage tip clearance flow occurs at all operating conditions, from design flow to near stall condition, with the large tip gap for the current compressor stage. The double-leakage tip clearance flow, its interaction with the tip clearance core vortex of the adjacent blade, and the resulting large mixing loss are the main flow mechanism of the large rotor tip gap in the compressor. When the tip clearance is smaller, flow near the end wall follows more closely with the main passage flow and this double-leakage tip clearance flow does not happen near the design flow condition for the current compressor stage. When the compressor with a large tip gap operates at near stall operation, a strong vortex rope is generated near the leading edge due to the double-leakage flow. Part of this vortex separates from the path of the tip clearance core vortex and travels from the suction side of the blade toward the pressure side of the blade. This vortex is generated periodically at near stall operation with a large tip gap. As the vortex travels from the suction side to the pressure side of the blade, a large fluctuation of local pressure forces blade vibration. Nonsynchronous blade vibration occurs due

  1. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.

    PubMed

    Bilici, Meki; Demir, Fikri; Akın, Alper; Türe, Mehmet; Balık, Hasan; Kuyumcu, Mahir

    2017-12-01

    The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.

  2. Magnet pole tips

    DOEpatents

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  3. Magnet pole tips

    DOEpatents

    Thorn, C.E.; Chasman, C.; Baltz, A.J.

    1981-11-19

    An improved magnet more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  4. Gas only nozzle fuel tip

    DOEpatents

    Bechtel, William Theodore; Fitts, David Orus; DeLeonardo, Guy Wayne

    2002-01-01

    A diffusion flame nozzle gas tip is provided to convert a dual fuel nozzle to a gas only nozzle. The nozzle tip diverts compressor discharge air from the passage feeding the diffusion nozzle air swirl vanes to a region vacated by removal of the dual fuel components, so that the diverted compressor discharge air can flow to and through effusion holes in the end cap plate of the nozzle tip. In a preferred embodiment, the nozzle gas tip defines a cavity for receiving the compressor discharge air from a peripheral passage of the nozzle for flow through the effusion openings defined in the end cap plate.

  5. Transcatheter Retrieval of Embolized Atrial Septal Defect Occluder Device by Waist Capture Technique.

    PubMed

    Her, Ae-Young; Lim, Kyung-Hun; Shin, Eun-Seok

    2018-01-27

    This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.

  6. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    PubMed

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusion<40% was considered abnormal. The device implantation was successful in all patients. Average perfusion of left lung was 44.7±4.9% (37.8-61.4). Five patients (16.6%) showed decreased perfusion of the left lung. Age, low weight, the length of the ductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  7. Families with Special Needs: Caregiving Tips

    MedlinePlus

    ... Halloween Prom Tips Spring Break Valentine Tips Winter Holiday Tips 12 Ways Holiday Song Healthy Living Check-Ups are Important Check- ... Test Wash Hands Stay Warm Have a Healthy Holiday Don’t Drink and Drive Widgets Healthy People ...

  8. Tip cap for a rotor blade

    NASA Technical Reports Server (NTRS)

    Kofel, W. K.; Tuley, E. N.; Gay, C. H., Jr.; Troeger, R. E.; Sterman, A. P. (Inventor)

    1983-01-01

    A replaceable tip cap for attachment to the end of a rotor blade is described. The tip cap includes a plurality of walls defining a compartment which, if desired, can be divided into a plurality of subcompartments. The tip cap can include inlet and outlet holes in walls thereof to permit fluid communication of a cooling fluid there through. Abrasive material can be attached with the radially outer wall of the tip cap.

  9. Novel fiber optic tip designs and devices for laser surgery

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas Clifton

    , assembled, and tested for use in Thulium fiber laser lithotripsy. A 1.00-mm-outer-diameter detachable fiber tip interface was designed, constructed, and tested ex vivo on urinary stones in the laboratory. Similar stone ablation rates between the previously studied tapered distal fiber tip and the detachable fiber tip were measured. For urologists desiring faster TFL lithotripsy procedures, the incorporation of detachable distal fiber tips allows for rapid replacement of damaged fiber tips without concern about the laser to trunk fiber connection. This method for preserving the trunk fiber could be a motivation for integrating a dedicated laser fiber into the ureteroscope, with detachable distal tips, thus freeing the working channel for the use of other surgical instruments. During laser lithotripsy, distal fiber tip degradation increases as the fiber core diameter decreases. However, smaller fiber diameters (≤ 200 microm) are more desirable because of increased saline irrigation rates in the single working channel of the ureteroscope and less impact on ureteroscope deflection. A hollow fiber cap is proposed to reduced fiber tip degradation in small diameter fibers, without compromising stone ablation rates. The disadvantage of the hollow fiber tip observed in the study is the increase in stone retropulsion. However, integrating the hollow fiber tip with a clinically used stone basket may allow for a robust stone ablation instrument that also minimizes retropulsion. These surgical approaches involving novel specialty fiber optic tip designs are discussed in this thesis.

  10. Characterization of the TIP4P-Ew water model: vapor pressure and boiling point.

    PubMed

    Horn, Hans W; Swope, William C; Pitera, Jed W

    2005-11-15

    The liquid-vapor-phase equilibrium properties of the previously developed TIP4P-Ew water model have been studied using thermodynamic integration free-energy simulation techniques in the temperature range of 274-400 K. We stress that free-energy results from simulations need to be corrected in order to be compared to the experiment. This is due to the fact that the thermodynamic end states accessible through simulations correspond to fictitious substances (classical rigid liquids and classical rigid ideal gases) while experiments operate on real substances (liquids and real gases, with quantum effects). After applying analytical corrections the vapor pressure curve obtained from simulated free-energy changes is in excellent agreement with the experimental vapor pressure curve. The boiling point of TIP4P-Ew water under ambient pressure is found to be at 370.3+/-1.9 K, about 7 K higher than the boiling point of TIP4P water (363.7+/-5.1 K; from simulations that employ finite range treatment of electrostatic and Lennard-Jones interactions). This is in contrast to the approximately +15 K by which the temperature of the density maximum and the melting temperature of TIP4P-Ew are shifted relative to TIP4P, indicating that the temperature range over which the liquid phase of TIP4P-Ew is stable is narrower than that of TIP4P and resembles more that of real water. The quality of the vapor pressure results highlights the success of TIP4P-Ew in describing the energetic and entropic aspects of intermolecular interactions in liquid water.

  11. Taxicab tipping and sunlight

    PubMed Central

    2017-01-01

    Does the level of sunlight affect the tipping percentage in taxicab rides in New York City? We examined this question using data on 13.82 million cab rides from January to October in 2009 in New York City combined with data on hourly levels of solar radiation. We found a small but statistically significant positive relationship between sunlight and tipping, with an estimated tipping increase of 0.5 to 0.7 percentage points when transitioning from a dark sky to full sunshine. The findings are robust to two-way clustering of standard errors based on hour-of-the-day and day-of-the-year and controlling for day-of-the-year, month-of-the-year, cab driver fixed effects, weather conditions, and ride characteristics. The NYC cab ride context is suitable for testing the association between sunlight and tipping due to the largely random assignment of riders to drivers, direct exposure to sunlight, and low confounding from variation in service experiences. PMID:28594917

  12. Taxicab tipping and sunlight.

    PubMed

    Devaraj, Srikant; Patel, Pankaj C

    2017-01-01

    Does the level of sunlight affect the tipping percentage in taxicab rides in New York City? We examined this question using data on 13.82 million cab rides from January to October in 2009 in New York City combined with data on hourly levels of solar radiation. We found a small but statistically significant positive relationship between sunlight and tipping, with an estimated tipping increase of 0.5 to 0.7 percentage points when transitioning from a dark sky to full sunshine. The findings are robust to two-way clustering of standard errors based on hour-of-the-day and day-of-the-year and controlling for day-of-the-year, month-of-the-year, cab driver fixed effects, weather conditions, and ride characteristics. The NYC cab ride context is suitable for testing the association between sunlight and tipping due to the largely random assignment of riders to drivers, direct exposure to sunlight, and low confounding from variation in service experiences.

  13. Gonioscopy-assisted Transluminal Trabeculotomy (GATT): Thermal Suture Modification With a Dye-stained Rounded Tip.

    PubMed

    Grover, Davinder S; Fellman, Ronald L

    2016-06-01

    To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.

  14. Treatment of patent ductus arteriosus by the use of an Amplatz canine ductal occluder device

    PubMed Central

    White, Pam

    2009-01-01

    A 7-month-old female, spayed border collie was referred to the Ontario Veterinary College due to a continuous murmur noted by the referring veterinarian prior to ovariohysterectomy. Auscultation confirmed a grade VI/VI continuous murmur. An echocardiogram confirmed patent ductus arteriosus (PDA). An Amplatz canine ductal occluder device was successfully placed for occlusion of blood flow though the ductus. PMID:19436449

  15. Early warning of climate tipping points

    NASA Astrophysics Data System (ADS)

    Lenton, Timothy M.

    2011-07-01

    A climate 'tipping point' occurs when a small change in forcing triggers a strongly nonlinear response in the internal dynamics of part of the climate system, qualitatively changing its future state. Human-induced climate change could push several large-scale 'tipping elements' past a tipping point. Candidates include irreversible melt of the Greenland ice sheet, dieback of the Amazon rainforest and shift of the West African monsoon. Recent assessments give an increased probability of future tipping events, and the corresponding impacts are estimated to be large, making them significant risks. Recent work shows that early warning of an approaching climate tipping point is possible in principle, and could have considerable value in reducing the risk that they pose.

  16. Quantitative assessment of intermolecular interactions by atomic force microscopy imaging using copper oxide tips

    NASA Astrophysics Data System (ADS)

    Mönig, Harry; Amirjalayer, Saeed; Timmer, Alexander; Hu, Zhixin; Liu, Lacheng; Díaz Arado, Oscar; Cnudde, Marvin; Strassert, Cristian Alejandro; Ji, Wei; Rohlfing, Michael; Fuchs, Harald

    2018-05-01

    Atomic force microscopy is an impressive tool with which to directly resolve the bonding structure of organic compounds1-5. The methodology usually involves chemical passivation of the probe-tip termination by attaching single molecules or atoms such as CO or Xe (refs 1,6-9). However, these probe particles are only weakly connected to the metallic apex, which results in considerable dynamic deflection. This probe particle deflection leads to pronounced image distortions, systematic overestimation of bond lengths, and in some cases even spurious bond-like contrast features, thus inhibiting reliable data interpretation8-12. Recently, an alternative approach to tip passivation has been used in which slightly indenting a tip into oxidized copper substrates and subsequent contrast analysis allows for the verification of an oxygen-terminated Cu tip13-15. Here we show that, due to the covalently bound configuration of the terminal oxygen atom, this copper oxide tip (CuOx tip) has a high structural stability, allowing not only a quantitative determination of individual bond lengths and access to bond order effects, but also reliable intermolecular bond characterization. In particular, by removing the previous limitations of flexible probe particles, we are able to provide conclusive experimental evidence for an unusual intermolecular N-Au-N three-centre bond. Furthermore, we demonstrate that CuOx tips allow the characterization of the strength and configuration of individual hydrogen bonds within a molecular assembly.

  17. Long-term outcome of 154 patients receiving balloon-occluded retrograde transvenous obliteration for gastric fundal varices.

    PubMed

    Imai, Yukinori; Nakazawa, Manabu; Ando, Satsuki; Sugawara, Kayoko; Mochida, Satoshi

    2016-11-01

    This study aims to clarify the long-term outcome of therapeutic strategies including balloon-occluded retrograde transvenous obliteration (B-RTO) for patients with gastric fundal varices. The subjects were 154 patients with gastric fundal varices fulfilling the criteria for receiving B-RTO. In patients showing variceal bleeding, endoscopic therapies and/or balloon tamponade was performed to achieve hemostasis. B-RTO was accomplished with injection of 5% ethanolamine oleate through a standard balloon catheter except for patients with atypical varices, in whom a microballoon catheter was used to occlude drainage vessels other than a gastrorenal shunt. In patients complicated with esophageal varices at baseline, endoscopic therapies were performed following B-RTO. Balloon-occluded retrograde transvenous obliteration was performed successfully in 147 patients (95%), including 15 patients using a microballoon catheter. Complete variceal obliteration was achieved in all patients. Additional endoscopic therapies for esophageal varices were performed in 31 patients. Gastric varices did not recur in any of these patients. The cumulative survival rates at 1, 3, and 5 years after B-RTO were 91%, 76%, and 72%, respectively. Child-Pugh scores and hepatocellular carcinoma complication were identified as prognostic factors associated with survival rates. The cumulative exacerbation rates of esophageal varices at 1, 3, and 5 years were 13%, 20%, and 27%, respectively, and rupture developed in six patients, which were successfully treated with endoscopic therapies. Therapeutic strategies including B-RTO with a microballoon catheter were useful to achieve a favorable outcome in patients with gastric fundal varices especially in those manifesting Child-Pugh class-A liver damage and/or those without hepatocellular carcinoma complication. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  18. Cochlear excitation by the near-field component during stimulation through the partially occluded round window

    NASA Astrophysics Data System (ADS)

    Weddell, Thomas D.; Yarin, Yury M.; Drexl, Markus; Russell, Ian J.; Elliott, Stephen J.; Lukashkin, Andrei N.

    2015-12-01

    The round window membrane (RW) provides pressure relief when the cochlea is excited by sound. While normal function of the RW is important for effective stimulation of the cochlea through the conventional oval window route, the cochlea can be stimulated successfully in non-conventional ways (e.g. through bone conduction, through the RW, and through perforations in the cochlea's apical turn). We report measurements of cochlear function from guinea pigs when the cochlea was stimulated at acoustic frequencies by movements of a miniature magnet which partially occluded the RW. Neural response latencies to acoustic and RW stimulation were similar and taken to indicate that both means of stimulation resulted in the generation of conventional travelling waves along the cochlear partition. It was concluded that the relatively high impedance of the ossicles, as seen from the cochlea, enabled the region of the RW not occluded by the magnet, to act as a pressure shunt during RW stimulation. We propose that travelling waves, similar to those due to acoustic far-field pressure changes, are driven by a jet-like, near-field component of a complex fluid-pressure field, which is generated by the magnetically vibrated RW.

  19. An investigation of tip planform influence on the aerodynamic load characteristics of semispan, upswept wing and wing-tip

    NASA Technical Reports Server (NTRS)

    Vanaken, Johannes M.

    1986-01-01

    A semi-span wing, equipped with an interchangeable tip, which was varied in planform and size was examined. Total wing aerodynamic loading was obtained from the wind tunnel scale system. The wing tip was mounted on a separate six-component strain gauge balance, which provided the aerodynamic loads on the tip. The tests were accomplished in the NASA Ames 7X10-Foot Wind Tunnel at a Mach number of 0.178. The aerodynamic load characteristics of the wing and of the tip were presented with the tip at several incidence angles relative to the wing inboard section.

  20. Turbine blade squealer tip rail with fence members

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, David A

    2012-11-20

    A turbine blade includes an airfoil, a blade tip section, a squealer tip rail, and a plurality of chordally spaced fence members. The blade tip section includes a blade tip floor located at an end of the airfoil distal from the root. The blade tip floor includes a pressure side and a suction side joined together at chordally spaced apart leading and trailing edges of the airfoil. The squealer tip rail extends radially outwardly from the blade tip floor adjacent to the suction side and extends from a first location adjacent to the airfoil trailing edge to a second locationmore » adjacent to the airfoil leading edge. The fence members are located between the airfoil leading and trailing edges and extend radially outwardly from the blade tip floor and axially from the squealer tip rail toward the pressure side.« less

  1. 29 CFR 516.28 - Tipped employees.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Tipped employees. 516.28 Section 516.28 Labor Regulations... EMPLOYERS Records Pertaining to Employees Subject to Miscellaneous Exemptions Under the Act; Other Special Requirements § 516.28 Tipped employees. (a) With respect to each tipped employee whose wages are determined...

  2. Normal and variant anatomy of the nasal tip.

    PubMed

    Ketcham, Amy S; Dobratz, Eric J

    2012-04-01

    A thorough understanding of nasal tip anatomy is a prerequisite to understanding the nuances of restructuring the nasal tip. The three-dimensional structural anatomy of the nasal tip is complex. Additionally, the interrelationship between these structures determines the ultimate form and function of the nasal tip. As a result, alteration of one structure in the tip will often lead to change in other portions of the nasal tip. This dynamic concept of anatomy in the nasal tip makes proper alteration of the nasal tip one of the most challenging tasks faced by a rhinoplasty surgeon. This article provides a fundamental knowledge of the normal anatomy of the tip structures and how their interaction with each other determines the shape and support of the lower portion of the nose. It also provides a description of some common variants of tip anatomy that cause patients to seek consultation for rhinoplasty. A proper understanding of the concepts presented provides a foundation to build on as the reader continues to explore the "nuances of the nasal tip." Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Impact of National Clinical Guideline Recommendations for Revascularization of Persistently Occluded Infarct-Related Arteries on Clinical Practice in the United States

    PubMed Central

    Deyell, Marc W.; Buller, Christopher E.; Miller, Louis H.; Wang, Tracy Y.; Dai, David; Lamas, Gervasio A.; Srinivas, Vankeepuram S.; Hochman, Judith S.

    2013-01-01

    Background The Occluded Artery Trial (OAT) was a large, randomized controlled trial published in 2006 that demonstrated no benefit to routine percutaneous coronary intervention (PCI) of persistently totally occluded infarct-related arteries (IRA) identified a minimum of 24 hours (on calendar days 3–28) after myocardial infarction (MI). The purpose of this study was to determine the impact of OAT results and consequent change in guideline recommendations for PCI for treatment of persistently occluded IRAs. Methods We identified all patients enrolled in the CathPCI Registry, from 2005 to 2008, undergoing catheterization more than 24 hours after MI with a totally occluded native coronary artery and no major OAT exclusion criteria. We examined trends in monthly rates of PCI for occlusions after OAT publication and after guideline revisions. Because reporting of diagnostic catheterizations was not mandatory, we examined trends among hospitals in the highest quartile for reporting of diagnostic procedures. Results A total of 28 780 patient visits from 896 hospitals were included. Overall, we found no significant decline in the adjusted monthly rate of PCI of occlusions after publication of OAT (odds ratio [OR], 0.997; 95% confidence interval [CI], 0.989–1.006) or after guideline revisions (OR, 1.007; 95% CI, 0.992–1.022). Among hospitals consistently reporting diagnostic catheterizations, there was no significant decline after OAT publication (OR, 1.018; 95% CI, 0.995–1.042), and there was a trend toward decline after guideline revisions (OR, 0.963; 95% CI, 0.920–1.000). Conclusion These findings suggest that the results of OAT and consequent guideline revisions have not, to date, been fully incorporated into clinical practice in a large cross-section of hospitals in the United States. PMID:21747002

  4. Southwestern Pine Tip Moth

    Treesearch

    Daniel T. Jennings; Robert E. Stevens

    1982-01-01

    The southwestern pine tip moth, Rhyacionia neomexicana (Dyar), injures young ponderosa pines (Pinus ponderosa Dougl. ex Laws) in the Southwest, central Rockies, and midwestern plains. Larvae feed on and destroy new, expanding shoots, often seriously reducing terminal growth of both naturally regenerated and planted pines. The tip moth is especially damaging to trees on...

  5. Analysis of Unsteady Tip and Endwall Heat Transfer in a Highly Loaded Transonic Turbine Stage

    NASA Technical Reports Server (NTRS)

    Shyam, Vikram; Ameri, Ali; Chen, Jen-Ping

    2010-01-01

    In a previous study, vane-rotor shock interactions and heat transfer on the rotor blade of a highly loaded transonic turbine stage were simulated. The geometry consists of a high pressure turbine vane and downstream rotor blade. This study focuses on the physics of flow and heat transfer in the rotor tip, casing and hub regions. The simulation was performed using the Unsteady Reynolds-Averaged Navier-Stokes (URANS) code MSU-TURBO. A low Reynolds number k-epsilon model was utilized to model turbulence. The rotor blade in question has a tip gap height of 2.1 percent of the blade height. The Reynolds number of the flow is approximately 3x10(exp 6) per meter. Unsteadiness was observed at the tip surface that results in intermittent "hot spots". It is demonstrated that unsteadiness in the tip gap is governed by inviscid effects due to high speed flow and is not strongly dependent on pressure ratio across the tip gap contrary to published observations that have primarily dealt with subsonic tip flows. The high relative Mach numbers in the tip gap lead to a choking of the leakage flow that translates to a relative attenuation of losses at higher loading. The efficacy of new tip geometry is discussed to minimize heat flux at the tip while maintaining choked conditions. In addition, an explanation is provided that shows the mechanism behind the rise in stagnation temperature on the casing to values above the absolute total temperature at the inlet. It is concluded that even in steady mode, work transfer to the near tip fluid occurs due to relative shearing by the casing. This is believed to be the first such explanation of the work transfer phenomenon in the open literature. The difference in pattern between steady and time-averaged heat flux at the hub is also explained.

  6. An optical fiber bundle sensor for tip clearance and tip timing measurements in a turbine rig.

    PubMed

    García, Iker; Beloki, Josu; Zubia, Joseba; Aldabaldetreku, Gotzon; Illarramendi, María Asunción; Jiménez, Felipe

    2013-06-05

    When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions.

  7. An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig

    PubMed Central

    García, Iker; Beloki, Josu; Zubia, Joseba; Aldabaldetreku, Gotzon; Illarramendi, María Asunción; Jiménez, Felipe

    2013-01-01

    When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions. PMID:23739163

  8. Shell-Isolated Tip-Enhanced Raman and Fluorescence Spectroscopy.

    PubMed

    Huang, Ya-Ping; Huang, Sheng-Chao; Wang, Xiang-Jie; Bodappa, Nataraju; Li, Chao-Yu; Yin, Hao; Su, Hai-Sheng; Meng, Meng; Zhang, Hua; Ren, Bin; Yang, Zhi-Lin; Zenobi, Renato; Tian, Zhong-Qun; Li, Jian-Feng

    2018-06-18

    Tip-enhanced Raman spectroscopy can provide molecular fingerprint information with ultrahigh spatial resolution, but the tip will be easily contaminated, thus leading to artifacts. It also remains a great challenge to establish tip-enhanced fluorescence because of the quenching resulting from the proximity of the metal tip. Herein, we report shell-isolated tip-enhanced Raman and fluorescence spectroscopies by employing ultrathin shell-isolated tips fabricated by atomic layer deposition. Such shell-isolated tips not only show outstanding electromagnetic field enhancement in TERS but also exclude interference by contaminants, thus greatly promoting applications in solution. Tip-enhanced fluorescence has also been achieved using these shell-isolated tips, with enhancement factors of up to 1.7×10 3 , consistent with theoretical simulations. Furthermore, tip-enhanced Raman and fluorescence signals are acquired simultaneously, and their relative intensities can be manipulated by changing the shell thickness. This work opens a new avenue for ultrahigh resolution surface analysis using plasmon-enhanced spectroscopies. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Sirt1 physically interacts with Tip60 and negatively regulates Tip60-mediated acetylation of H2AX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamagata, Kazutsune, E-mail: kyamagat@ncc.go.jp; Kitabayashi, Issay

    2009-12-25

    Sirt1 appear to be NAD(+)-dependent deacetylase that deacetylates histones and several non-histone proteins. In this study, we identified Sirt1 as a physical interaction partner of Tip60, which is a mammalian MYST-type histone acetyl-transferase that specifically acetylates histones H2A and H4. Although Tip60 also acetylates DNA damage-specific histone H2A variant H2AX in response to DNA damage, which is a process required for appropriate DNA damage response, overexpression of Sirt1 represses Tip60-mediated acetylation of H2AX. Furthermore, Sirt1 depletion by RNAi causes excessive acetylation of H2AX, and enhances accumulation of {gamma}-ray irradiation-induced MDC1, BRCA1, and Rad51 foci in nuclei. These findings suggest thatmore » Sirt1 functions as negative regulator of Tip60-mediated acetylation of H2AX. Moreover, Sirt1 deacetylates an acetylated Tip60 in response to DNA damage and stimulates proteasome-dependent Tip60 degradation in vivo, suggesting that Sirt1 negatively regulates the protein level of Tip60 in vivo. Sirt1 may thus repress excessive activation of the DNA damage response and Rad51-homologous recombination repair by suppressing the function of Tip60.« less

  10. Tip-Enhanced Raman Scattering Imaging of Two-Dimensional Tungsten Disulfide with Optimized Tip Fabrication Process.

    PubMed

    Lee, Chanwoo; Kim, Sung Tae; Jeong, Byeong Geun; Yun, Seok Joon; Song, Young Jae; Lee, Young Hee; Park, Doo Jae; Jeong, Mun Seok

    2017-01-13

    We successfully achieve the tip-enhanced nano Raman scattering images of a tungsten disulfide monolayer with optimizing a fabrication method of gold nanotip by controlling the concentration of etchant in an electrochemical etching process. By applying a square-wave voltage supplied from an arbitrary waveform generator to a gold wire, which is immersed in a hydrochloric acid solution diluted with ethanol at various ratios, we find that both the conical angle and radius of curvature of the tip apex can be varied by changing the ratio of hydrochloric acid and ethanol. We also suggest a model to explain the origin of these variations in the tip shape. From the systematic study, we find an optimal condition for achieving the yield of ~60% with the radius of ~34 nm and the cone angle of ~35°. Using representative tips fabricated under the optimal etching condition, we demonstrate the tip-enhanced Raman scattering experiment of tungsten disulfide monolayer grown by a chemical vapor deposition method with a spatial resolution of ~40 nm and a Raman enhancement factor of ~4,760.

  11. Tipping elements in the Earth's climate system.

    PubMed

    Lenton, Timothy M; Held, Hermann; Kriegler, Elmar; Hall, Jim W; Lucht, Wolfgang; Rahmstorf, Stefan; Schellnhuber, Hans Joachim

    2008-02-12

    The term "tipping point" commonly refers to a critical threshold at which a tiny perturbation can qualitatively alter the state or development of a system. Here we introduce the term "tipping element" to describe large-scale components of the Earth system that may pass a tipping point. We critically evaluate potential policy-relevant tipping elements in the climate system under anthropogenic forcing, drawing on the pertinent literature and a recent international workshop to compile a short list, and we assess where their tipping points lie. An expert elicitation is used to help rank their sensitivity to global warming and the uncertainty about the underlying physical mechanisms. Then we explain how, in principle, early warning systems could be established to detect the proximity of some tipping points.

  12. Structure of the bacteriophage T4 long tail fiber receptor-binding tip

    PubMed Central

    Bartual, Sergio G.; Otero, José M.; Garcia-Doval, Carmela; Llamas-Saiz, Antonio L.; Kahn, Richard; Fox, Gavin C.; van Raaij, Mark J.

    2010-01-01

    Bacteriophages are the most numerous organisms in the biosphere. In spite of their biological significance and the spectrum of potential applications, little high-resolution structural detail is available on their receptor-binding fibers. Here we present the crystal structure of the receptor-binding tip of the bacteriophage T4 long tail fiber, which is highly homologous to the tip of the bacteriophage lambda side tail fibers. This structure reveals an unusual elongated six-stranded antiparallel beta-strand needle domain containing seven iron ions coordinated by histidine residues arranged colinearly along the core of the biological unit. At the end of the tip, the three chains intertwine forming a broader head domain, which contains the putative receptor interaction site. The structure reveals a previously unknown beta-structured fibrous fold, provides insights into the remarkable stability of the fiber, and suggests a framework for mutations to expand or modulate receptor-binding specificity. PMID:21041684

  13. In vivo production of recombinant proteins using occluded recombinant AcMNPV-derived baculovirus vectors.

    PubMed

    Guijarro-Pardo, Eva; Gómez-Sebastián, Silvia; Escribano, José M

    2017-12-01

    Trichoplusia ni insect larvae infected with vectors derived from the Autographa californica multiple nucleopolyhedrovirus (AcMNPV), are an excellent alternative to insect cells cultured in conventional bioreactors to produce recombinant proteins because productivity and cost-efficiency reasons. However, there is still a lot of work to do to reduce the manual procedures commonly required in this production platform that limit its scalability. To increase the scalability of this platform technology, a current bottleneck to be circumvented in the future is the need of injection for the inoculation of larvae with polyhedrin negative baculovirus vectors (Polh-) because of the lack of oral infectivity of these viruses, which are commonly used for production in insect cell cultures. In this work we have developed a straightforward alternative to obtain orally infective vectors derived from AcMNPV and expressing recombinant proteins that can be administered to the insect larvae (Trichoplusia ni) by feeding, formulated in the insect diet. The approach developed was based on the use of a recombinant polyhedrin protein expressed by a recombinant vector (Polh+), able to co-occlude any recombinant Polh- baculovirus vector expressing a recombinant protein. A second alternative was developed by the generation of a dual vector co-expressing the recombinant polyhedrin protein and the foreign gene of interest to obtain the occluded viruses. Additionally, by the incorporation of a reporter gene into the helper Polh+ vector, it was possible the follow-up visualization of the co-occluded viruses infection in insect larvae and will help to homogenize infection conditions. By using these methodologies, the production of recombinant proteins in per os infected larvae, without manual infection procedures, was very similar in yield to that obtained by manual injection of recombinant Polh- AcMNPV-based vectors expressing the same proteins. However, further analyses will be required for a

  14. Oxygen-Free Welding Contact Tips

    NASA Technical Reports Server (NTRS)

    Pike, James F.

    1993-01-01

    Contact tips for gas/metal arc welding (GMAW) fabricated from oxygen-free copper. Prototype tips tested in robotic welding, for which application intended. Reduces electrical erosion, increases electrical conductivity, and reduces mechanical wear. Productivity of robotic welding increases while time during welding interrupted for removal and replacement of contact tips minimal. Improves alignment of joints and filler metal, reducing rate of rejection and repair of unacceptable weldments. Utility extends beyond aerospace industry to mass production of various types of hardware, including heavy off-highway construction equipment.

  15. Cultural evolutionary tipping points in the storage and transmission of information.

    PubMed

    Bentley, R Alexander; O'Brien, Michael J

    2012-01-01

    Human culture has evolved through a series of major tipping points in information storage and communication. The first was the appearance of language, which enabled communication between brains and allowed humans to specialize in what they do and to participate in complex mating games. The second was information storage outside the brain, most obviously expressed in the "Upper Paleolithic Revolution" - the sudden proliferation of cave art, personal adornment, and ritual in Europe some 35,000-45,000 years ago. More recently, this storage has taken the form of writing, mass media, and now the Internet, which is arguably overwhelming humans' ability to discern relevant information. The third tipping point was the appearance of technology capable of accumulating and manipulating vast amounts of information outside humans, thus removing them as bottlenecks to a seemingly self-perpetuating process of knowledge explosion. Important components of any discussion of cultural evolutionary tipping points are tempo and mode, given that the rate of change, as well as the kind of change, in information storage and transmission has not been constant over the previous million years.

  16. Low photon-count tip-tilt sensor

    NASA Astrophysics Data System (ADS)

    Saathof, Rudolf; Schitter, Georg

    2016-07-01

    Due to the low photon-count of dark areas of the universe, signal strength of tip-tilt sensor is low, limiting sky-coverage of reliable tip-tilt measurements. This paper presents the low photon-count tip-tilt (LPC-TT) sensor, which potentially achieves improved signal strength. Its optical design spatially samples and integrates the scene. This increases the probability that several individual sources coincide on a detector segment. Laboratory experiments show feasibility of spatial sampling and integration and the ability to measure tilt angles. By simulation an improvement of the SNR of 10 dB compared to conventional tip-tilt sensors is shown.

  17. RANS computations of tip vortex cavitation

    NASA Astrophysics Data System (ADS)

    Decaix, Jean; Balarac, Guillaume; Dreyer, Matthieu; Farhat, Mohamed; Münch, Cécile

    2015-12-01

    The present study is related to the development of the tip vortex cavitation in Kaplan turbines. The investigation is carried out on a simplified test case consisting of a NACA0009 blade with a gap between the blade tip and the side wall. Computations with and without cavitation are performed using a R ANS modelling and a transport equation for the liquid volume fraction. Compared with experimental data, the R ANS computations turn out to be able to capture accurately the development of the tip vortex. The simulations have also highlighted the influence of cavitation on the tip vortex trajectory.

  18. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    PubMed

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  19. Smart helicopter rotor with active blade tips

    NASA Astrophysics Data System (ADS)

    Bernhard, Andreas Paul Friedrich

    2000-10-01

    The smart active blade tip (SABT) rotor is an on-blade rotor vibration reduction system, incorporating active blade tips that can be independently pitched with respect to the main blade. The active blade tip rotor development included an experimental test program culminating in a Mach scale hover test, and a parallel development of a coupled, elastic actuator and rotor blade analysis for preliminary design studies and hover performance prediction. The experimental testing focussed on a small scale rotor on a bearingless Bell-412 hub. The fabricated Mach-scale active-tip rotor has a diameter of 1.524 m, a blade chord of 76.2 mm and incorporated a 10% span active tip. The nominal operating speed is 2000 rpm, giving a tip Mach number of 0.47. The blade tips are driven by a novel piezo-induced bending-torsion coupled actuator beam, located spanwise in the hollow mid-cell of the main rotor blade. In hover at 2000 rpm, at 2 deg collective, and for an actuation of 125 Vrms, the measured blade tip deflection at the first four rotor harmonics is between +/-1.7 and +/-2.8 deg, increasing to +/-5.3 deg at 5/rev with resonant amplification. The corresponding oscillatory amplitude of the rotor thrust coefficient is between 0.7 · 10-3 and 1.3 · 10-1 at the first four rotor harmonics, increasing to 2.1 · 10-3 at 5/rev. In general, the experimental blade tip frequency response and corresponding rotor thrust response are well captured by the analysis. The flexbeam root flap bending moment is predicted in trend, but is significantly over-estimated. The blade tips did not deflect as expected at high collective settings, because of the blade tip shaft locking up in the bearing. This is caused by the high flap bending moment on the blade tip shaft. Redesign of the blade tip shaft assembly and bearing support is identified as the primary design improvement for future research. The active blade tip rotor was also used as a testbed for the evaluation of an adaptive neural-network based

  20. Tipping elements in the Earth's climate system

    PubMed Central

    Lenton, Timothy M.; Held, Hermann; Kriegler, Elmar; Hall, Jim W.; Lucht, Wolfgang; Rahmstorf, Stefan; Schellnhuber, Hans Joachim

    2008-01-01

    The term “tipping point” commonly refers to a critical threshold at which a tiny perturbation can qualitatively alter the state or development of a system. Here we introduce the term “tipping element” to describe large-scale components of the Earth system that may pass a tipping point. We critically evaluate potential policy-relevant tipping elements in the climate system under anthropogenic forcing, drawing on the pertinent literature and a recent international workshop to compile a short list, and we assess where their tipping points lie. An expert elicitation is used to help rank their sensitivity to global warming and the uncertainty about the underlying physical mechanisms. Then we explain how, in principle, early warning systems could be established to detect the proximity of some tipping points. PMID:18258748

  1. Biophysical Characterization of the Type III Secretion Tip Proteins and the Tip Proteins Attached to Bacterium-Like Particles

    PubMed Central

    Choudhari, Shyamal P.; Chen, Xiaotong; Kim, Jae Hyun; van Roosmalen, Maarten L.; Greenwood, Jamie C.; Joshi, Sangeeta B.; Picking, William D.; Leenhouts, Kees; Middaugh, C. Russell; Picking, Wendy L.

    2014-01-01

    Bacterium-like particles (BLPs), derived from Lactococcus lactis, offer a self-adjuvanting delivery vehicle for subunit protein vaccines. Proteins can be specifically loaded onto the BLPs via a peptidoglycan anchoring domain (PA). In this study, the tip proteins IpaD, SipD and LcrV belonging to type three secretion systems of Shigella flexneri, Salmonella enterica and Yersinia enterocolitica, respectively, were fused to the PA and loaded onto the BLPs. Herein, we biophysically characterized these nine samples and condensed the spectroscopic results into three-index empirical phase diagrams (EPDs). The EPDs show distinctions between the IpaD/SipD and LcrV subfamilies of tip proteins, based on their physical stability, even upon addition of the PA. Upon attachment to the BLPs, the BLPs become defining moiety in the spectroscopic measurements, leaving the tip proteins to have a subtle yet modulating effect on the structural integrity of the tip proteins-BLPs binding. In summary, this work provides a comprehensive view of physical stability of the tip proteins and tip protein-BLPs and serves as a baseline for screening of excipients to increase the stability of the tip protein-BLPs for future vaccine formulation. PMID:24916512

  2. Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.

    PubMed

    Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G

    2013-04-01

    This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.

  3. Aerodynamic tip desensitization in axial flow turbines

    NASA Astrophysics Data System (ADS)

    Dey, Debashis

    The leakage flow near the tip of unshrouded rotor blades in axial turbines imposes significant thermal loads on the blade. It is also responsible for up to a third of aerodynamic losses in a turbine stage. The leakage flow, mainly induced by the pressure differential across the rotor tip section, usually rolls into a stream-wise vertical structure near the suction side part of the blade tip. The current study uses several concepts to reduce the severity of losses introduced by the leakage vortex. Three tip desensitization techniques, both active and passive, are examined. Coolant flow from a tip trench is used to counter the momentum of the leakage jet. Next, a very short winglet obtained by slightly extending the tip platform in the tangential direction is investigated. Lastly, the widely used concept of squealer tip is studied. The current investigation is performed in the Axial Flow Turbine Research Facility (AFTRF) of the Pennsylvania State University. Rotating frame five hole probe measurements as well as stationary frame phase averaged total pressure measurements downstream of a single stage turbine facility were taken. The study enables one to draw conclusions about the nature of the flowfield in the rotor tip region. It also shows that significant efficiency gains could be obtained by using some of these techniques.

  4. Investigation of Unsteady Flow Field in a Low-Speed One and a Half Stage Axial Compressor. Part 2; Effects of Tip Gap Size On the Tip Clearance Flow Structure at Near Stall Operation

    NASA Technical Reports Server (NTRS)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph

    2014-01-01

    The primary focus of this paper is to investigate the effect of rotor tip gap size on how the rotor unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor at near stall operation (for example, where maximum pressure rise is obtained). A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at this flow condition with both a small and a large tip gaps. The numerically obtained flow fields at the small clearance matches fairly well with the available initial measurements obtained at the Johns Hopkins University with 3-D unsteady PIV in an index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. The numerical results are also compared with previously published measurements in a low speed single stage compressor (Maerz et al. [2002]). The current study shows that, with the smaller rotor tip gap, the tip clearance vortex moves to the leading edge plane at near stall operating condition, creating a nearly circumferentially aligned vortex that persists around the entire rotor. On the other hand, with a large tip gap, the clearance vortex stays inside the blade passage at near stall operation. With the large tip gap, flow instability and related large pressure fluctuation at the leading edge are observed in this one and a half stage compressor. Detailed examination of the unsteady flow structure in this compressor stage reveals that the flow instability is due to shed vortices near the leading edge, and not due to a three-dimensional separation vortex originating from the suction side of the blade, which is commonly referred to during a spike-type stall inception. The entire tip clearance flow is highly unsteady. Many vortex structures in the tip clearance flow, including the sheet vortex system near the casing, interact with each other. The

  5. Forces and electronic transport in a contact formed by a graphene tip and a defective MoS2 monolayer: a theoretical study.

    PubMed

    di Felice, D; Dappe, Y J; González, C

    2018-06-01

    A theoretical study of a graphene-like tip used in atomic force microscopy (AFM) is presented. Based on first principles simulations, we proved the low reactivity of this kind of tip, using a MoS 2 monolayer as the testing sample. Our simulations show that the tip-MoS 2 interaction is mediated through weak van der Waals forces. Even on the defective monolayer, the interaction is reduced by one order of magnitude with respect to the values obtained using a highly reactive metallic tip. On the pristine monolayer, the S atoms were imaged for large distances together with the substitutional defects which should be observed as brighter spots in non-contact AFM measurements. This result is in contradiction with previous simulations performed with Cu or Si tips where the metallic defects were imaged for much larger distances than the S atoms. For shorter distances, the Mo sites will be brighter even though a vacancy is formed. On the other hand, the largest conductance value is obtained over the defect formed by two Mo atoms occupying a S divacancy when the half-occupied p y -states of the graphene-like tip find a better coupling with d-orbitals of the highest substitutional atom. Due to the weak interaction, no conductance plateau is formed in any of the sites. A great advantage of this tip lies in the absence of atomic transfer between the tip and the sample leading to a more stable AFM measurement. Finally, and as previously shown, we confirm the atomic resolution in a scanning tunneling microscopy simulation using this graphene-based tip.

  6. Spectral analysis of airflow sounds in patent versus occluded tracheostomy tubes: a pilot study in tracheostomized adult patients.

    PubMed

    Rao, A J; Niwa, H; Watanabe, Y; Fukuta, S; Yanagita, N

    1990-05-01

    Cannula occlusion is a life-threatening postoperative complication of tracheostomy. Current management largely relies on nursing care for prevention of fatalities because no proven mechanical, machine-based support monitoring exists. The objective of this paper was to address the problem of monitoring the state of cannula patency, based on analysis of airflow acoustic spectral patterns in tracheostomized adult patients in the patent and partially occluded cannula. Tracheal airflow sounds were picked up via a condenser microphone air-coupled to the skin just below the tracheal stoma. Signal output from Mic was amplified, high-pass filtered, digital tape-recorded, and analyzed on a mainframe computer. Although airflow frequencies for patient cannulae were predominantly low-pitched (0.1 to 0.3 kHz), occluded tubes had discrete high-pitched spectral peaks (1.3 to 1.6 kHz). These results suggest that frequency analysis of airflow sounds can identify a change in the status of cannula patency.

  7. Nasal Sculpting: Calculated and Predictable Tip Elevation With Cephalic Trim

    PubMed Central

    Redstone, Jeremiah S.; Nguyen, Jonathan; North, Durham Alan; Hazani, Ron; Drury, Brad; Yoder, Eric M.; Cooperman, Ross D.; Yoder, Virginia; Little, Jarrod A.; Florman, Larry D.; Wilhelmi, Bradon J.

    2015-01-01

    Background: Rhinoplasty techniques to affect nasal tip rotation are well described. Cephalic alar trim is a powerful method for achieving tip elevation. Previous studies and texts provide aesthetic guidelines for nasolabial angles. Often, surgeon experience determines the degree of lower lateral cartilage resection to achieve optimal results. This study analyzes the change in tip elevation with measured resections of the lower lateral cartilages. This can aid the surgeon in accurately predicting the effect of cephalic alar trim on tip elevation. Methods: Ten fresh cadaveric dissections were performed to determine the change in nasolabial angles after cephalic trim of the lower lateral cartilage. Closed rhinoplasty technique was performed using marginal and intercartilaginous incisions to expose the lower lateral cartilage. Caliper measurements of the lower lateral cartilage were recorded. Serial cephalic trim was performed in 25% increments. True lateral photographs were obtained before and after each serial excision. Nasolabial angle measurements were obtained using a digital goniometer for digital photo analysis. Results: Four female and 6 male cadavers were evaluated. The mean initial nasolabial angle was 106° ± 2°. The mean lower lateral cartilage width was 9.45 ± 1.38 mm. Serial 25% reductions in lower lateral cartilage height resulted in a mean total nasolabial angle change of 7.4°, 12.9°, and 19.6°, respectively. The mean incremental change in the nasolabial angle was 6.47° ± 1.25°. Conclusion: The nasolabial angle is an essential aesthetic feature. Cephalic trim is a key maneuver in affecting the nasolabial angle. A 25% lower lateral cartilage cephalic trim correlates with an average change in the nasolabial angle of 6.47°. Knowledge of the cephalic trim to nasolabial angle relationship aids in achieving desired tip elevation. PMID:26171091

  8. Blade tip, finite aspect ratio, and dynamic stall effects on the Darrieus rotor

    NASA Astrophysics Data System (ADS)

    Paraschivoiu, I.; Desy, P.; Masson, C.

    1988-02-01

    The objective of the work described in this paper was to apply the Boeing-Vertol dynamic stall model in an asymmetric manner to account for the asymmetry of the flow between the left and right sides of the rotor. This phenomenon has been observed by the flow visualization of a two-straight-bladed Darrieus rotor in the IMST water tunnel. Also introduced into the aerodynamic model are the effects of the blade tip and finite aspect ratio on the aerodynamic performance of the Darrieus wind turbine. These improvements are compatible with the double-multiple-streamtube model and have been included in the CARDAAV computer code for predicting the aerodynamic performance. Very good agreement has been observed between the test data (Sandia 17 m) and theoretical predictions; a significant improvement over the previous dynamic stall model was obtained for the rotor power at low tip speed ratios, while the inclusion of the finite aspect ratio effects enhances the prediction of the rotor power for high tip speed ratios. The tip losses and finite aspect ratio effects were also calculated for a small-scale vertical-axis wind turbine, with a two-straight-bladed (NACA 0015) rotor.

  9. Characterization of closely related delta-TIP genes encoding aquaporins which are differentially expressed in sunflower roots upon water deprivation through exposure to air.

    PubMed

    Sarda, X; Tousch, D; Ferrare, K; Cellier, F; Alcon, C; Dupuis, J M; Casse, F; Lamaze, T

    1999-05-01

    We isolated five sunflower (Helianthus annuus) cDNAs belonging to the TIP (tonoplast intrinsic protein) family. SunRb7 and Sun gammaTIP (partial sequence) are homologous to tobacco TobRb7 and Arabidopsis gamma-TIP, respectively. SunTIP7, 18 and 20 (SunTIPs) are closely related and homologous to Arabidopsis delta-TIP (SunTIP7 and 20 have already been presented in Sarda et al., Plant J. 12 (1997) 1103-1111). As was previously shown for SunTIP7 and 20, expression of SunTIP18 and SunRb7 in Xenopus oocytes caused an increase in osmotic water permeability demonstrating that they are aquaporins. In roots, in situ hybridization revealed that SunTIP7 and 18 mRNAs accumulate in phloem tissues. The expression of TIP-like genes was studied in roots during 24 h water deprivation through exposure to air. During the course of the treatment, each SunTIP gene displayed an individual response: SunTIP7 transcript abundance increased, SunTIP18 decreased whereas that of SunTIP20 was transitorily enhanced. By contrast, SunRb7 and Sun gammaTIP mRNA levels did not fluctuate. Due to the changes in their transcript levels, it is proposed that SUNTIP aquaporins encoded by delta-TIP-like genes play a role in the sunflower response to drought.

  10. Topology, divergence dates, and macroevolutionary inferences vary between different tip-dating approaches applied to fossil theropods (Dinosauria).

    PubMed

    Bapst, D W; Wright, A M; Matzke, N J; Lloyd, G T

    2016-07-01

    Dated phylogenies of fossil taxa allow palaeobiologists to estimate the timing of major divergences and placement of extinct lineages, and to test macroevolutionary hypotheses. Recently developed Bayesian 'tip-dating' methods simultaneously infer and date the branching relationships among fossil taxa, and infer putative ancestral relationships. Using a previously published dataset for extinct theropod dinosaurs, we contrast the dated relationships inferred by several tip-dating approaches and evaluate potential downstream effects on phylogenetic comparative methods. We also compare tip-dating analyses to maximum-parsimony trees time-scaled via alternative a posteriori approaches including via the probabilistic cal3 method. Among tip-dating analyses, we find opposing but strongly supported relationships, despite similarity in inferred ancestors. Overall, tip-dating methods infer divergence dates often millions (or tens of millions) of years older than the earliest stratigraphic appearance of that clade. Model-comparison analyses of the pattern of body-size evolution found that the support for evolutionary mode can vary across and between tree samples from cal3 and tip-dating approaches. These differences suggest that model and software choice in dating analyses can have a substantial impact on the dated phylogenies obtained and broader evolutionary inferences. © 2016 The Author(s).

  11. Enhanced Actuator Line Simulation of a Wind Turbine by including the Conservative Load at the Blade Tip

    NASA Astrophysics Data System (ADS)

    Herraez, Ivan; Micallef, Daniel; van Kuik, Gijs A. M.; Peinke, Joachim

    2015-11-01

    At the tip of wind turbine blades, the radial bound circulation is transformed into chordwise circulation just before being released as trailing vorticity, giving rise to the tip vortex. The force acting on the chordwise circulation contains a radial and a normal component with respect to the blade axis. This load does not contribute to the torque, so it is a conservative load. Due to this, it is disregarded in the engineering tools used for the design of wind turbines. However, as we demonstrated in a previous work, the conservative load might influence the trajectory of the tip vortex. In order to see how this affects the blade loads, in this research we perform large eddy simulations with an actuator line model where the conservative load has been included. The conservative load reduces the angle of attack in the tip region as a consequence of the modified tip vortex trajectory. This has a negative influence on the lift and the power output. We conclude that the accuracy of engineering design tools of wind turbines can be improved if the conservative load acting at the tip is considered.

  12. Tips for Good Electronic Presentations.

    ERIC Educational Resources Information Center

    Strasser, Dennis

    1996-01-01

    Describes library uses of presentation graphics software and offers tips for creating electronic presentations. Tips include: audience retention; visual aid options; software package options; presentation planning; presentation showing; and use of text, colors, and graphics. Sidebars note common presentation errors and popular presentation…

  13. An experimental investigation of free-tip response to a jet

    NASA Technical Reports Server (NTRS)

    Young, L. A.

    1986-01-01

    The aerodynamic response of passively oscillating tips appended to a model helicopter rotor was investigated during a whirl test. Tip responsiveness was found to meet free-tip rotor requirements. Experimental and analytical estimates of the free-tip aerodynamic spring, mechanical spring, and aerodynamic damping were calculated and compared. The free tips were analytically demonstrated to be operating outside the tip resonant response region at full-scale tip speeds. Further, tip resonance was shown to be independent of tip speed, given the assumption that the tip forcing frequency is linearly dependent upon the rotor rotational speed.

  14. Tipping Points in Texas Rivers

    NASA Astrophysics Data System (ADS)

    Phillips, Jonathan

    2016-04-01

    Anticipating geomorphic tipping points requires that we learn from the past. Major geomorphic changes in coastal plain rivers of Texas resulting in river metamorphosis or regime shifts were identified, and the major driving factors determined. Nine fluvial tipping points were identified from contemporary observations, historical records, and Quaternary reconstructions. Two of the tipping points (between general aggrading and degrading valley states) are associated with reversals in a fundamental system control (sea-level). One (stable or aggrading vs. degrading channels) is associated with an abrupt change in sediment supply due to dam construction, and two others (changes from meandering to anastomosing channel patterns, and different anastomosis styles) are similarly related to changes in sediment supply and/or transport capacity, but with additional elements of historical contingency. Three tipping points are related to avulsions. One, from a regime dominated to reoccupation of former channels to one dominated by progradation into flood basins, is driven by progressive long term filling of incised valleys. Another, nodal avulsions, are driven by disturbances associated with tectonics or listric faults. The third, avulsions and related valley metamorphosis in unfilled incised valleys, is due to fundamental dynamical instabilities within the fluvial system. This synthesis and analysis suggests that geomorphic tipping points are sometimes associated with general extrinsic or intrinsic (to the fluvial system) environmental change, independent of any disturbances or instabilities. Others are associated with natural (e.g., tectonic) or human (dams) disturbances, and still others with intrinsic geomorphic instabilities. This suggests that future tipping points will be equally diverse with respect to their drivers.

  15. Terahertz Nanofocusing with Cantilevered Terahertz-Resonant Antenna Tips.

    PubMed

    Mastel, Stefan; Lundeberg, Mark B; Alonso-González, Pablo; Gao, Yuanda; Watanabe, Kenji; Taniguchi, Takashi; Hone, James; Koppens, Frank H L; Nikitin, Alexey Y; Hillenbrand, Rainer

    2017-11-08

    We developed THz-resonant scanning probe tips, yielding strongly enhanced and nanoscale confined THz near fields at their tip apex. The tips with length in the order of the THz wavelength (λ = 96.5 μm) were fabricated by focused ion beam (FIB) machining and attached to standard atomic force microscopy (AFM) cantilevers. Measurements of the near-field intensity at the very tip apex (25 nm radius) as a function of tip length, via graphene-based (thermoelectric) near-field detection, indicate their first and second order geometrical antenna resonances for tip length of 33 and 78 μm, respectively. On resonance, we find that the near-field intensity is enhanced by one order of magnitude compared to tips of 17 μm length (standard AFM tip length), which is corroborated by numerical simulations that further predict remarkable intensity enhancements of about 10 7 relative to the incident field. Because of the strong field enhancement and standard AFM operation of our tips, we envision manifold and straightforward future application in scattering-type THz near-field nanoscopy and THz photocurrent nanoimaging, nanoscale nonlinear THz imaging, or nanoscale control and manipulation of matter employing ultrastrong and ultrashort THz pulses.

  16. ST-depression in right precordial leads with inferior STEMI and occluded right coronary artery: intertwined anatomy and ischemic areas.

    PubMed

    De Gennaro, Luisa; Brunetti, Natale Daniele; Ruggiero, Massimo; Rutigliano, David; Locuratolo, Nicola; Di Biase, Matteo; Caldarola, Pasquale

    2017-10-01

    Right coronary artery (RCA) occlusion in inferior acute myocardial infarction is usually heralded by ST-elevation both in inferior and in right precordial leads. We report the case of a 68-year-old male, who presented marked ST-elevation in inferior leads, mirrored by ST-depression in anterior-septal and lateral leads. Right precordial lead electrocardiogram unexpectedly showed ST-depression V1R-V5R leads. Coronary angiography showed mid-left anterior descending (LAD) coronary near-complete occlusion with distal wrapping LAD. Left circumflex artery was not occluded, while RCA was occluded mid tract. The patient was treated with coronary angioplasty on RCA and LAD. Absence of ST-elevation in right precordial leads may be presumably explained by the presence of a large ischemic area distal to mid-LAD near-occlusive stenosis and of a long-wrapping LAD. Complex coronary anatomy and intertwined ischemic areas may underlie apparently discording electrocardiograms.

  17. Tip cap for a turbine rotor blade

    DOEpatents

    Kimmel, Keith D

    2014-03-25

    A turbine rotor blade with a spar and shell construction, and a tip cap that includes a row of lugs extending from a bottom side that form dovetail grooves that engage with similar shaped lugs and grooves on a tip end of the spar to secure the tip cap to the spar against radial displacement. The lug on the trailing edge end of the tip cap is aligned perpendicular to a chordwise line of the blade in the trailing edge region in order to minimize stress due to the lugs wanting to bend under high centrifugal loads. A two piece tip cap with lugs at different angles will reduce the bending stress even more.

  18. Efficacy of air/water syringe tip sterilization.

    PubMed

    Inger, M; Bennani, V; Farella, M; Bennani, F; Cannon, R D

    2014-03-01

    Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones. © 2014 Australian Dental Association.

  19. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration

    PubMed Central

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-01-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment. PMID:27956966

  20. Comparison of different types of phacoemulsification tips. I. Quantitative analysis of elemental composition and tip surface microroughness.

    PubMed

    Tsaousis, Konstantinos T; Werner, Liliana; Perez, Jesus Paulo; Li, He J; Reiter, Nicholas; Guan, Jia J; Mamalis, Nick

    2016-09-01

    To evaluate the elemental composition of phacoemulsification tips and their surface roughness in the microscale. John A. Moran Eye Center and Utah Nanofab, College of Engineering, University of Utah, Salt Lake City, Utah, USA. Experimental study. Seven types of phacoemulsification tips were studied. The phaco tips were examined through energy-dispersive x-ray spectroscopy (EDS) and x-ray photoelectron spectroscopy (XPS) for elemental composition. In addition, the roughness of the opening in all tips was assessed through 3-dimensional white-light interferometry. Elemental analysis showed considerable differences in the surface layers between manufacturers. Alcon tips had a thinner oxidized titanium (Ti) layer in their surface. Through XPS, vanadium was not detected in the superficial layers of any tip, but only in deeper levels. The microroughness surface analysis showed comparable results regarding their root-mean-square (RMS) metric. Maximum peak valley distance values varied and appeared to be dependent on the quality of material process rather than the material itself. Phacoemulsification tips are made of Ti alloys and showed differences between models, especially regarding their composition in the superficial layers. Their opening end roughness showed an overall appropriate RMS value of less than 1.0 μm in all cases. The existence of small defected areas highlights the importance of adequate quality control of these critical surgical instruments. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Mapping cavitation activity around dental ultrasonic tips.

    PubMed

    Walmsley, A Damien; Lea, Simon C; Felver, Bernhard; King, David C; Price, Gareth J

    2013-05-01

    Cavitation arising within the water around the oscillating ultrasonic scaler tip is an area that may lead to advances in enhancing biofilm removal. The aim of this study is to map the occurrence of cavitation around scaler tips under loaded conditions. Two designs of piezoelectric ultrasonic scaling probes were evaluated with a scanning laser vibrometer and luminol dosimetric system under loaded (100 g/200 g) and unloaded conditions. Loads were applied to the probe tips via teeth mounted in a load-measuring apparatus. There was a positive correlation between probe displacement amplitude and cavitation production for ultrasonic probes. The position of cavitation at the tip of each probe was greater under loaded conditions than unloaded and for the longer P probe towards the tip. Whilst increasing vibration displacement amplitude of ultrasonic scalers increases the occurrence of cavitation, factors such as the length of the probe influence the amount of cavitation activity generated. The application of load affects the production of cavitation at the most clinically relevant area-the tip. Loading and the design of ultrasonic scalers lead to maximising the occurrence of the cavitation at the tip and enhance the cleaning efficiency of the scaler.

  2. [TIPS

    PubMed

    Brazzini, Augusto; Carrillo, Alvaro; Cantella, Raúl

    1998-01-01

    Esophageal hemorrage due to variceal bleeding in cirrhotic patients represents a serious problem for the physician in charge, especially in this country where liver transplants are inexistent; and also, it is a drama for the patient and its familly. We propose here the Transjugular Intrahepatic Portosystemic Shunt (TIPS). Twenty one patients were part of a study where 23 TIPS were placed, observing an immediate improval in 18 of them, a rebleeding in 2, within the first 24 and 48 hours. An embolization of the coronary veins was performed in the procedure in 15 patients, and a second intervention due to rebleeding in 2 of them. In the latter patients, the embolization of the coronary veins was rutinary.The survival of the patients has been outstanding.We conclude that this interventional procedure is a worldwide reality in the treatment of esophageal hemorrage by variceal bleeding due to portal hipertension, and it does not cut down the probability of liver transplant, unfortunately inexistent in our country. This procedure results in a low morbimortality with an adequate quality of life.

  3. The possible involvement of root-cap mucilage in gravitropism and calcium movement across root tips of Allium cepa L

    NASA Technical Reports Server (NTRS)

    Moore, R.; Fondren, W. M.

    1986-01-01

    Roots of Allium cepa L. grown in aerated water elongate rapidly, but are not graviresponsive. These roots (1) possess extensive columella tissues comprised of cells containing numerous sedimented amyloplasts, (2) lack mucilage on their tips, and (3) are characterized by a weakly polar movement of calcium (Ca) across their tips. Placing roots in humid air correlates positively with the (1) onset of gravicurvature, (2) appearance of mucilage on tips of the roots, and (3) onset of the ability to transport Ca polarly to the lower side of the root tip. Gravicurvature of roots previously submerged in aerated water is more rapid when roots are oriented vertically for 1-2 h in humid air prior to being oriented horizontally. The more rapid gravicurvature of these roots correlates positively with the accumulation of mucilage at the tips of roots during the time the roots are oriented vertically. Therefore, the onset of gravicurvature and the ability of roots to transport Ca to the lower sides of their tips correlate positively with the presence of mucilage at their tips. These results suggest that mucilage may be important for the transport of Ca across root caps.

  4. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    NASA Astrophysics Data System (ADS)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2014-05-01

    The accurate control of the gap between static and rotating components is vital to preserve the mechanical integrity and ensure a correct functioning of any rotating machinery. Moreover, tip leakage above the airfoil tip results in relevant aerodynamic losses. One way to measure and to monitor blade tip gaps is by the so-called Blade Tip Clearance (BTC) technique. Another fundamental phenomenon to control in the turbomachines is the vibration of the blades. For more than half a century, this has been performed by installing strain gauges on the blades and using telemetry to transmit the signals. The Blade Tip Timing (BTT) technique, (i.e. measuring the blade time of arrival from the casing at different angular locations with proximity sensors) is currently being adopted by all manufacturers as a replacement for the classical strain gauge technique because of its non-intrusive character. This paper presents a novel magnetoresistive sensor for blade tip timing and blade tip clearance systems, which offers high temporal and high spatial resolution simultaneously. The sensing element adopted is a Wheatstone bridge of Permalloy elements. The principle of the sensor is based on the variation of magnetic field at the passage of ferromagnetic objects. Two different configurations have been realized, a digital and an analogue sensor. Measurements of tip clearance have been performed in an high speed compressor and the calibration curve is reported. Measurements of blade vibration have been carried out in a dedicated calibration bench; results are presented and discussed. The magnetoresistive sensor is characterized by high repeatability, low manufacturing costs and measurement accuracy in line with the main probes used in turbomachinery testing. The novel sensor has great potential and is capable of fulfilling the requirements for a simultaneous BTC and BTT measurement system.

  5. The tonoplast intrinsic aquaporin (TIP) subfamily of Eucalyptus grandis: Characterization of EgTIP2, a root-specific and osmotic stress-responsive gene.

    PubMed

    Rodrigues, Marcela I; Bravo, Juliana P; Sassaki, Flávio T; Severino, Fábio E; Maia, Ivan G

    2013-12-01

    Aquaporins have important roles in various physiological processes in plants, including growth, development and adaptation to stress. In this study, a gene encoding a root-specific tonoplast intrinsic aquaporin (TIP) from Eucalyptus grandis (named EgTIP2) was investigated. The root-specific expression of EgTIP2 was validated over a panel of five eucalyptus organ/tissues. In eucalyptus roots, EgTIP2 expression was significantly induced by osmotic stress imposed by PEG treatment. Histochemical analysis of transgenic tobacco lines (Nicotiana tabacum SR1) harboring an EgTIP2 promoter:GUS reporter cassette revealed major GUS staining in the vasculature and in root tips. Consistent with its osmotic-stress inducible expression in eucalyptus, EgTIP2 promoter activity was up-regulated by mannitol treatment, but was down-regulated by abscisic acid. Taken together, these results suggest that EgTIP2 might be involved in eucalyptus response to drought. Additional searches in the eucalyptus genome revealed the presence of four additional putative TIP coding genes, which could be individually assigned to the classical TIP1-5 groups. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. An Experimental Characterization of Tip Leakage Flows and Corresponding Effects on Multistage Compressor Performance

    NASA Astrophysics Data System (ADS)

    Berdanier, Reid Adam

    The effect of rotor tip clearances in turbomachinery applications has been a primary research interest for nearly 80 years. Over that time, studies have shown increased tip clearance in axial flow compressors typically has a detrimental effect on overall pressure rise capability, isentropic efficiency, and stall margin. With modern engine designs trending toward decreased core sizes to increase propulsive efficiency (by increasing bypass ratio) or additional compression stages to increase thermal efficiency by increasing the overall pressure ratio, blade heights in the rear stages of the high pressure compressor are expected to decrease. These rear stages typically feature smaller blade aspect ratios, for which endwall flows are more important, and the rotor tip clearance height represents a larger fraction of blade span. As a result, data sets collected with large relative rotor tip clearance heights are necessary to facilitate these future small core design goals. This research seeks to characterize rotor tip leakage flows for three tip clearance heights in the Purdue three-stage axial compressor facility (1.5%, 3.0%, and 4.0% as a percentage of overall annulus height). The multistage environment of this compressor provides the unique opportunity to examine tip leakage flow effects due to stage matching, stator-rotor interactions, and rotor-rotor interactions. The important tip leakage flow effects which develop as a result of these interactions are absent for previous studies which have been conducted using single-stage machines or isolated rotors. A series of compressor performance maps comprise points at four corrected speeds for each of the three rotor tip clearance heights. Steady total pressure and total temperature measurements highlight the effects of tip leakage flows on radial profiles and wake shapes throughout the compressor. These data also evaluate tip clearance effects on efficiency, stall margin, and peak pressure rise capability. An emphasis of

  7. Arctic tipping points in an Earth system perspective.

    PubMed

    Wassmann, Paul; Lenton, Timothy M

    2012-02-01

    We provide an introduction to the volume The Arctic in the Earth System perspective: the role of tipping points. The terms tipping point and tipping element are described and their role in current science, general debates, and the Arctic are elucidated. From a wider perspective, the volume focuses upon the role of humans in the Arctic component of the Earth system and in particular the envelope for human existence, the Arctic ecosystems. The Arctic climate tipping elements, the tipping elements in Arctic ecosystems and societies, and the challenges of governance and anticipation are illuminated through short summaries of eight publications that derive from the Arctic Frontiers conference in 2011 and the EU FP7 project Arctic Tipping Points. Then some ideas based upon resilience thinking are developed to show how wise system management could ease pressures on Arctic systems in order to keep them away from tipping points.

  8. Compressor airfoil tip clearance optimization system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary.more » During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.« less

  9. Tip-over Prevention: Adaptive Control Development

    DTIC Science & Technology

    2015-05-30

    used to detect tip- over, with the FA and MHS metrics providing more effective stability measurements than the ZMP metric, in some cases indicating tip...support polygon formed by the robot’s ground contact points, as shown in Figure 1. If the Fig. 1. Tip-over angle definition in Force-Angle stability...0 (6) Therefore, the sum of the inertial, centripetal, Coriolis , and gravitational terms can be used to estimate the impact forces: fI,z = ω̇xry

  10. Tips for Postpartum Dads and Partners

    MedlinePlus

    ... Blues: Partners Interview with Wade Bowen Coping with Suicide & Loss Tips for Postpartum Dads and Partners Pregnancy and postpartum mood and anxiety disorders affect the whole family. Here are some tips ...

  11. Forces and electronic transport in a contact formed by a graphene tip and a defective MoS2 monolayer: a theoretical study

    NASA Astrophysics Data System (ADS)

    di Felice, D.; Dappe, Y. J.; González, C.

    2018-06-01

    A theoretical study of a graphene-like tip used in atomic force microscopy (AFM) is presented. Based on first principles simulations, we proved the low reactivity of this kind of tip, using a MoS2 monolayer as the testing sample. Our simulations show that the tip–MoS2 interaction is mediated through weak van der Waals forces. Even on the defective monolayer, the interaction is reduced by one order of magnitude with respect to the values obtained using a highly reactive metallic tip. On the pristine monolayer, the S atoms were imaged for large distances together with the substitutional defects which should be observed as brighter spots in non-contact AFM measurements. This result is in contradiction with previous simulations performed with Cu or Si tips where the metallic defects were imaged for much larger distances than the S atoms. For shorter distances, the Mo sites will be brighter even though a vacancy is formed. On the other hand, the largest conductance value is obtained over the defect formed by two Mo atoms occupying a S divacancy when the half-occupied p y -states of the graphene-like tip find a better coupling with d-orbitals of the highest substitutional atom. Due to the weak interaction, no conductance plateau is formed in any of the sites. A great advantage of this tip lies in the absence of atomic transfer between the tip and the sample leading to a more stable AFM measurement. Finally, and as previously shown, we confirm the atomic resolution in a scanning tunneling microscopy simulation using this graphene-based tip.

  12. Cultural Evolutionary Tipping Points in the Storage and Transmission of Information

    PubMed Central

    Bentley, R. Alexander; O’Brien, Michael J.

    2012-01-01

    Human culture has evolved through a series of major tipping points in information storage and communication. The first was the appearance of language, which enabled communication between brains and allowed humans to specialize in what they do and to participate in complex mating games. The second was information storage outside the brain, most obviously expressed in the “Upper Paleolithic Revolution” – the sudden proliferation of cave art, personal adornment, and ritual in Europe some 35,000–45,000 years ago. More recently, this storage has taken the form of writing, mass media, and now the Internet, which is arguably overwhelming humans’ ability to discern relevant information. The third tipping point was the appearance of technology capable of accumulating and manipulating vast amounts of information outside humans, thus removing them as bottlenecks to a seemingly self-perpetuating process of knowledge explosion. Important components of any discussion of cultural evolutionary tipping points are tempo and mode, given that the rate of change, as well as the kind of change, in information storage and transmission has not been constant over the previous million years. PMID:23267338

  13. An Experimental Investigation of the Functional Hypothesis and Evolutionary Advantage of Stone-Tipped Spears

    PubMed Central

    Wilkins, Jayne; Schoville, Benjamin J.; Brown, Kyle S.

    2014-01-01

    Stone-tipped weapons were a significant innovation for Middle Pleistocene hominins. Hafted hunting technology represents the development of new cognitive and social learning mechanisms within the genus Homo, and may have provided a foraging advantage over simpler forms of hunting technology, such as a sharpened wooden spear. However, the nature of this foraging advantage has not been confirmed. Experimental studies and ethnographic reports provide conflicting results regarding the relative importance of the functional, economic, and social roles of hafted hunting technology. The controlled experiment reported here was designed to test the functional hypothesis for stone-tipped weapons using spears and ballistics gelatin. It differs from previous investigations of this type because it includes a quantitative analysis of wound track profiles and focuses specifically on hand-delivered spear technology. Our results do not support the hypothesis that tipped spears penetrate deeper than untipped spears. However, tipped spears create a significantly larger inner wound cavity that widens distally. This inner wound cavity is analogous to the permanent wound cavity in ballistics research, which is considered the key variable affecting the relative ‘stopping power’ or ‘killing power’ of a penetrating weapon. Tipped spears conferred a functional advantage to Middle Pleistocene hominins, potentially affecting the frequency and regularity of hunting success with important implications for human adaptation and life history. PMID:25162397

  14. Integrated Turbine Tip Clearance and Gas Turbine Engine Simulation

    NASA Technical Reports Server (NTRS)

    Chapman, Jeffryes W.; Kratz, Jonathan; Guo, Ten-Huei; Litt, Jonathan

    2016-01-01

    Gas turbine compressor and turbine blade tip clearance (i.e., the radial distance between the blade tip of an axial compressor or turbine and the containment structure) is a major contributing factor to gas path sealing, and can significantly affect engine efficiency and operational temperature. This paper details the creation of a generic but realistic high pressure turbine tip clearance model that may be used to facilitate active tip clearance control system research. This model uses a first principles approach to approximate thermal and mechanical deformations of the turbine system, taking into account the rotor, shroud, and blade tip components. Validation of the tip clearance model shows that the results are realistic and reflect values found in literature. In addition, this model has been integrated with a gas turbine engine simulation, creating a platform to explore engine performance as tip clearance is adjusted. Results from the integrated model explore the effects of tip clearance on engine operation and highlight advantages of tip clearance management.

  15. Dynamics of Isolated Tip Vortex Cavitation

    NASA Astrophysics Data System (ADS)

    Pennings, Pepijn; Bosschers, Johan; van Terwisga, Tom

    2014-11-01

    Performance of ship propellers and comfort levels in the surroundings are limited by various forms of cavitation. Amongst these forms tip vortex cavitation is one of the first appearing forms and is expected to be mainly responsible for the emission of broadband pressure fluctuations typically occurring between the 4th to the 7th blade passing frequency (approx. 40--70 Hz). These radiated pressure pulses are likely to excite parts of the hull structure resulting in a design compromise between efficiency and comfort. Insight is needed in the mechanism of acoustic emission from the oscillations by a tip vortex cavity. In the current experimental study the tip vortex cavity from a blade with an elliptic planform and sections based on NACA 662 - 415 with meanline a = 0 . 8 is observed using high speed shadowgraphy in combination with blade force and acoustic measurements. An analytic model describing three main cavity deformation modes is verified and used to explain the origin of a cavity eigenfrequency or ``vortex singing'' phenomenon observed by Maines and Arndt (1997) on the tip vortex cavity originating from the same blade. As no hydrodynamic sound originating from the tip vortex cavity was observed it is posed that a tip flow instability is essential for ``vortex singing.'' This research was funded by the Lloyd's Register Foundation as part of the International Institute for Cavitation Research.

  16. Towards force spectroscopy of single tip-link bonds

    NASA Astrophysics Data System (ADS)

    Koussa, Mounir A.; Sotomayor, Marcos; Wong, Wesley P.; Corey, David P.

    2015-12-01

    Inner-ear mechanotransduction relies on tip links, fine protein filaments made of cadherin-23 and protocadherin-15 that convey tension to mechanosensitive channels at the tips of hair-cell stereocilia. The tip-link cadherins are thought to form a heterotetrameric complex, with two cadherin-23 molecules forming the upper part of the filament and two protocadherin-15 molecules forming the lower end. The interaction between cadherin-23 and protocadherin-15 is mediated by their N-terminal tips. Missense mutations that modify the interaction interface impair binding and lead to deafness. Molecular dynamics simulations predict that the tip-link bond is mechanically strong enough to withstand forces in hair cells, but its experimentally determined strength is unknown. We have developed molecular tools to facilitate single-molecule force spectroscopy on the tip link bond. Self-assembling DNA nanoswitches are functionalized with the interacting tips of cadherin-23 and protocadherin-15 using the enzyme sortase under conditions that preserve protein function. These tip link nanoswitches are designed to provide a signature force-extension profile. This molecular signature should allow us to identify single-molecule rupture events in pulling experiments.

  17. The Role of Visual Area V4 in the Discrimination of Partially Occluded Shapes

    PubMed Central

    Kosai, Yoshito; El-Shamayleh, Yasmine; Fyall, Amber M.

    2014-01-01

    The primate brain successfully recognizes objects, even when they are partially occluded. To begin to elucidate the neural substrates of this perceptual capacity, we measured the responses of shape-selective neurons in visual area V4 while monkeys discriminated pairs of shapes under varying degrees of occlusion. We found that neuronal shape selectivity always decreased with increasing occlusion level, with some neurons being notably more robust to occlusion than others. The responses of neurons that maintained their selectivity across a wider range of occlusion levels were often sufficiently sensitive to support behavioral performance. Many of these same neurons were distinctively selective for the curvature of local boundary features and their shape tuning was well fit by a model of boundary curvature (curvature-tuned neurons). A significant subset of V4 neurons also signaled the animal's upcoming behavioral choices; these decision signals had short onset latencies that emerged progressively later for higher occlusion levels. The time course of the decision signals in V4 paralleled that of shape selectivity in curvature-tuned neurons: shape selectivity in curvature-tuned neurons, but not others, emerged earlier than the decision signals. These findings provide evidence for the involvement of contour-based mechanisms in the segmentation and recognition of partially occluded objects, consistent with psychophysical theory. Furthermore, they suggest that area V4 participates in the representation of the relevant sensory signals and the generation of decision signals underlying discrimination. PMID:24948811

  18. Surface- and tip-enhanced Raman spectroscopy reveals spin-waves in iron oxide nanoparticles

    NASA Astrophysics Data System (ADS)

    Rodriguez, Raul D.; Sheremet, Evgeniya; Deckert-Gaudig, Tanja; Chaneac, Corinne; Hietschold, Michael; Deckert, Volker; Zahn, Dietrich R. T.

    2015-05-01

    Nanomaterials have the remarkable characteristic of displaying physical properties different from their bulk counterparts. An additional degree of complexity and functionality arises when oxide nanoparticles interact with metallic nanostructures. In this context the Raman spectra due to plasmonic enhancement of iron oxide nanocrystals are here reported showing the activation of spin-waves. Iron oxide nanoparticles on gold and silver tips are found to display a band around 1584 cm-1 attributed to a spin-wave magnon mode. This magnon mode is not observed for nanoparticles deposited on silicon (111) or on glass substrates. Metal-nanoparticle interaction and the strongly localized electromagnetic field contribute to the appearance of this mode. The localized excitation that generates this mode is confirmed by tip-enhanced Raman spectroscopy (TERS). The appearance of the spin-waves only when the TERS tip is in close proximity to a nanocrystal edge suggests that the coupling of a localized plasmon with spin-waves arises due to broken symmetry at the nanoparticle border and the additional electric field confinement. Beyond phonon confinement effects previously reported in similar systems, this work offers significant insights on the plasmon-assisted generation and detection of spin-waves optically induced.Nanomaterials have the remarkable characteristic of displaying physical properties different from their bulk counterparts. An additional degree of complexity and functionality arises when oxide nanoparticles interact with metallic nanostructures. In this context the Raman spectra due to plasmonic enhancement of iron oxide nanocrystals are here reported showing the activation of spin-waves. Iron oxide nanoparticles on gold and silver tips are found to display a band around 1584 cm-1 attributed to a spin-wave magnon mode. This magnon mode is not observed for nanoparticles deposited on silicon (111) or on glass substrates. Metal-nanoparticle interaction and the strongly

  19. Comparison of calculated and measured velocities near the tip of a model rotor blade at transonic speeds

    NASA Technical Reports Server (NTRS)

    Tauber, M. E.; Owen, F. K.; Langhi, R. G.; Palmer, G. E.

    1985-01-01

    The ability of the ROT22 code to predict accurately the transonic flow field in the crucial region around and beyond the tip of a high speed rotor blade was assessed. The computations were compared with extensive laser velocimetry measurements made at zero advance ratio and tip Mach numbers of 0.85, 0.88, 0.90, and 0.95. The comparison between theory and experiment was made using 300 scans for the three orthogonal velocity components covering a volume having a height of over one blade chord, a width of nearly two chords, and a length ranging from about 1 to 1.6 chords, depending on the tip speeds. The good agreement between the calculated and measured velocities established the ability of the code to predict the off blade flow field at high tip speeds. This supplements previous comparisons where surface pressures were shown to be well predicted on two different tips at advance ratios to 0.45, especially at the critical 90 deg azimuth blade position. These results demonstrate that the ROT22 code can be used with confidence to predict the important tip region flow field including the occurrence, strength, and location of shock waves causing high drag and noise.

  20. Effect of Electric Field Gradient on Sub-nanometer Spatial Resolution of Tip-enhanced Raman Spectroscopy

    PubMed Central

    Meng, Lingyan; Yang, Zhilin; Chen, Jianing; Sun, Mengtao

    2015-01-01

    Tip-enhanced Raman spectroscopy (TERS) with sub-nanometer spatial resolution has been recently demonstrated experimentally. However, the physical mechanism underlying is still under discussion. Here we theoretically investigate the electric field gradient of a coupled tip-substrate system. Our calculations suggest that the ultra-high spatial resolution of TERS can be partially attributed to the electric field gradient effect owning to its tighter spatial confinement and sensitivity to the infrared (IR)-active of molecules. Particularly, in the case of TERS of flat-lying H2TBPP molecules,we find the electric field gradient enhancement is the dominating factor for the high spatial resolution, which qualitatively coincides with previous experimental report. Our theoretical study offers a new paradigm for understanding the mechanisms of the ultra-high spatial resolution demonstrated in tip-enhanced spectroscopy which is of importance but neglected. PMID:25784161

  1. Fiber optic muzzle brake tip for reducing fiber burnback and stone retropulsion during thulium fiber laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-01-01

    The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A "fiber muzzle brake" was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-outer-diameter, 360-μm-inner-diameter tube with a 275-μm-diameter through hole located 250 μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40±4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25±4 s (n=10) without visible distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers, respectively. The muzzle brake fiber tip simultaneously provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  2. Optical fiber meta-tips

    NASA Astrophysics Data System (ADS)

    Principe, Maria; Micco, Alberto; Crescitelli, Alessio; Castaldi, Giuseppe; Consales, Marco; Esposito, Emanuela; La Ferrara, Vera; Galdi, Vincenzo; Cusano, Andrea

    2016-04-01

    We report on the first example of a "meta-tip" configuration that integrates a metasurface on the tip of an optical fiber. Our proposed design is based on an inverted-Babinet plasmonic metasurface obtained by patterning (via focused ion beam) a thin gold film deposited on the tip of an optical fiber, so as to realize an array of rectangular aperture nanoantennas with spatially modulated sizes. By properly tuning the resonances of the aperture nanoantennas, abrupt variations can be impressed in the field wavefront and polarization. We fabricated and characterized several proof-of-principle prototypes operating an near-infrared wavelengths, and implementing the beam-steering (with various angles) of the cross-polarized component, as well as the excitation of surface waves. Our results pave the way to the integration of the exceptional field-manipulation capabilities enabled by metasurfaces with the versatility and ubiquity of fiber-optics technological platforms.

  3. Lithotripsy Performance of Specially Designed Laser Fiber Tips.

    PubMed

    Kronenberg, Peter; Traxer, Olivier

    2016-05-01

    We evaluated and compared a standard laser lithotripsy fiber to laser fibers claimed to have lithotripsy performance enhancing features. A special AccuMax™ 200 polished tip fiber and an AccuTrac™ ball-shaped tip fiber, each with an approximately 240 μm core, were compared to a standard 272 μm core fiber (Rocamed™). The polished and ball-shaped tip fibers were used and reused without preparation. The standard fiber was stripped and cleaved according to manufacturer instructions after each experiment. An automated laser fragmentation testing system was used to perform multiple 30-second laser lithotripsy experiments. To mimic most typical lithotripsy conditions soft and hard stone materials were used with high frequency, low pulse energy (20 Hz and 0.5 J) or with low frequency, high pulse energy (5 Hz and 2.0 J) lithotripter settings. Ablation volumes and laser fiber tip photographs before and after lithotripsy were compared. The standard and ball-shaped tip fibers did not differ in ablation volume (p = 0.72) but they ablated 174% and 188% more stone, respectively, than the polished tip fiber (p <0.0001). The ball-shaped tip showed remarkable fiber tip degradation after short-term use at low frequency, high pulse energy settings. When high pulse energy settings were applied first even for short-term use, the ablation volume achieved by the polished and ball-shaped tip fibers at high frequency, low pulse energy settings decreased more than 20%. The standard laser fiber was as good as and sometimes better than the specially designed fibers. Rapid degradation of the specially designed laser fiber tips strongly limits their general usefulness but ball-shaped tip fibers may be useful in specific situations. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Local Mass and Heat Transfer on a Turbine Blade Tip

    DOE PAGES

    Jin, P.; Goldstein, R. J.

    2003-01-01

    Locmore » al mass and heat transfer measurements on a simulated high-pressure turbine blade-tip surface are conducted in a linear cascade with a nonmoving tip endwall, using a naphthalene sublimation technique. The effects of tip clearance (0.86–6.90% of chord) are investigated at various exit Reynolds numbers (4–7 × 10 5 ) and turbulence intensities (0.2 and 12.0%). The mass transfer on the tip surface is significant along its pressure edge at the smallest tip clearance. At the two largest tip clearances, the separation bubble on the tip surface can cover the whole width of the tip on the second half of the tip surface. The average mass-transfer rate is highest at a tip clearance of 1.72% of chord. The average mass-transfer rate on the tip surface is four and six times as high as on the suction and the pressure surface, respectively. A high mainstream turbulence level of 12.0% reduces average mass-transfer rates on the tip surface, while the higher mainstream Reynolds number generates higher local and average mass-transfer rates on the tip surface.« less

  5. Note: Microelectrode-shielding tip for scanning probe electron energy spectroscopy

    NASA Astrophysics Data System (ADS)

    Huang, Wei; Li, Zhean; Xu, Chunkai; Liu, Jian; Xu, Chunye; Chen, Xiangjun

    2018-04-01

    We report a novel microelectrode-shielding tip (ME tip) for scanning probe electron energy spectroscopy (SPEES). The shielding effect of this tip is studied through comparing the detection efficiency with the normal tip by both experiment and simulation. The results show that the backscattering count rate detected by the SPEES instrument using the normal tip begins to decrease as the tip approaches to the sample surface within 21 μm, while that using the ME tip only starts to drop off within 1 μm. This indicates that the electron energy spectra can be measured with the ME tip at a much closer tip-sample distance. Furthermore, it is also demonstrated that the ME tip can be used to obtain topography of the sample surface in situ simultaneously.

  6. 7 CFR 29.3154 - Tips (T Group).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... stalk. (See Rule 12.) Grades Grade names and specifications T3F Good Tan Tips. Medium body, mature to...″ in length, 85 percent uniform, and 15 percent injury tolerance. T4F Fair Tan Tips. Medium body..., and 20 percent injury tolerance. T5F Low Tan Tips. Medium body, mature, firm, wrinkly, dingy finish...

  7. 7 CFR 29.3154 - Tips (T Group).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... stalk. (See Rule 12.) Grades Grade names and specifications T3F Good Tan Tips. Medium body, mature to...″ in length, 85 percent uniform, and 15 percent injury tolerance. T4F Fair Tan Tips. Medium body..., and 20 percent injury tolerance. T5F Low Tan Tips. Medium body, mature, firm, wrinkly, dingy finish...

  8. Injector tip for an internal combustion engine

    DOEpatents

    Shyu, Tsu Pin; Ye, Wen

    2003-05-20

    This invention relates to a the tip structure of a fuel injector as used in a internal combustion engine. Internal combustion engines using Homogeneous Charge Compression Ignition (HCCI) technology require a tip structure that directs fuel spray in a downward direction. This requirement necessitates a tip design that is capable of withstanding mechanical stresses associated with the design.

  9. Turbine blade tip flow discouragers

    DOEpatents

    Bunker, Ronald Scott

    2000-01-01

    A turbine assembly comprises a plurality of rotating blade portions in a spaced relation with a stationery shroud. The rotating blade portions comprise a root section, a tip portion and an airfoil. The tip portion has a pressure side wall and a suction side wall. A number of flow discouragers are disposed on the blade tip portion. In one embodiment, the flow discouragers extend circumferentially from the pressure side wall to the suction side wall so as to be aligned generally parallel to the direction of rotation. In an alternative embodiment, the flow discouragers extend circumferentially from the pressure side wall to the suction side wall so as to be aligned at an angle in the range between about 0.degree. to about 60.degree. with respect to a reference axis aligned generally parallel to the direction of rotation. The flow discouragers increase the flow resistance and thus reduce the flow of hot gas flow leakage for a given pressure differential across the blade tip portion so as to improve overall turbine efficiency.

  10. Effect of rotor tip clearance and configuration on overall performance of a 12.77-centimeter tip diameter axial-flow turbine

    NASA Technical Reports Server (NTRS)

    Haas, J. E.; Kofskey, M. G.

    1978-01-01

    The rotor tip clearance was obtained by use of a recess in the casing above the rotor blades and also by use of a reduced blade height. For the recessed casing configuration, the optimum rotor blade height was found to be the one where the rotor tip diameter was equal to the stator tip diameter. The tip clearance loss associated with this optimum recessed casing configuration was less than that for the reduced blade height configuration.

  11. Dynamic of cold-atom tips in anharmonic potentials

    PubMed Central

    Menold, Tobias; Federsel, Peter; Rogulj, Carola; Hölscher, Hendrik; Fortágh, József

    2016-01-01

    Background: Understanding the dynamics of ultracold quantum gases in an anharmonic potential is essential for applications in the new field of cold-atom scanning probe microscopy. Therein, cold atomic ensembles are used as sensitive probe tips to investigate nanostructured surfaces and surface-near potentials, which typically cause anharmonic tip motion. Results: Besides a theoretical description of this anharmonic tip motion, we introduce a novel method for detecting the cold-atom tip dynamics in situ and real time. In agreement with theory, the first measurements show that particle interactions and anharmonic motion have a significant impact on the tip dynamics. Conclusion: Our findings will be crucial for the realization of high-sensitivity force spectroscopy with cold-atom tips and could possibly allow for the development of advanced spectroscopic techniques such as Q-control. PMID:28144505

  12. Efficacy and safety of a single 2 mg dose or 4 mg double dose of alteplase for 50 occluded chest ports using a unique instillation technique.

    PubMed

    Sharma, Rajinder P; Ree, Chung Ja; Ree, Alexander

    2008-01-01

    To evaluate the effectiveness and safety of a single 2 mg dose or a 4 mg double dose of alteplase for restoring function in occluded chest ports. A prospective, open-label, nonblinded study was performed on 40 enrolled patients with a total of 50 chest ports at the Henry Ford Hospital Interventional Radiology Department (Detroid, Michigan, USA). Alteplase (Cathflo Activase; Genentech, USA), a recombinant tissue plasminogen activator produced by recombinant DNA technology, was used to restore the function of 50 occluded chest ports. Occlusion was defined as the inability to withdraw blood freely from the port, or the inability to flush the port easily. A 2 mg (2 mL) dose of alteplase was injected into the port through a Huber needle, using a gentle push and pull technique, and was left to dwell for 30 min. If the port remained occluded after the initial 2 mg alteplase treatment, an additional 2 mg alteplase treatment was administered with the same dwell time of 30 min. If a port had remained occluded despite the above regimen, this outcome would have been considered a failure and the chest port would have required surgical intervention. However, all ports were successfully treated, and no surgical intervention was required. The safety end points included minor or major hemorrhages, such as intracranial hemorrhages, or sepsis. Safety end points were determined by a 24 h follow-up telephone call. Of the 50 chest ports (30 single ports and 10 double ports) treated with alteplase, 36 required 2 mg (72%) and 14 required 4 mg (28%). The efficacy end point was 100% for all chest ports treated, without any adverse events. High efficacy and safety rates of restoring function in occluded chest ports were obtained with 2 mg or 4 mg doses of alteplase. Part of this high efficacy rate may be due to the gentle push and pull technique used in the present study.

  13. Efficacy and safety of a single 2 mg dose or 4 mg double dose of alteplase for 50 occluded chest ports using a unique instillation technique

    PubMed Central

    Sharma, Rajinder P; Ree, Chung Ja; Ree, Alexander

    2008-01-01

    PURPOSE: To evaluate the effectiveness and safety of a single 2 mg dose or a 4 mg double dose of alteplase for restoring function in occluded chest ports. METHODS: A prospective, open-label, nonblinded study was performed on 40 enrolled patients with a total of 50 chest ports at the Henry Ford Hospital Interventional Radiology Department (Detroid, Michigan, USA). Alteplase (Cathflo Activase; Genentech, USA), a recombinant tissue plasminogen activator produced by recombinant DNA technology, was used to restore the function of 50 occluded chest ports. Occlusion was defined as the inability to withdraw blood freely from the port, or the inability to flush the port easily. A 2 mg (2 mL) dose of alteplase was injected into the port through a Huber needle, using a gentle push and pull technique, and was left to dwell for 30 min. If the port remained occluded after the initial 2 mg alteplase treatment, an additional 2 mg alteplase treatment was administered with the same dwell time of 30 min. If a port had remained occluded despite the above regimen, this outcome would have been considered a failure and the chest port would have required surgical intervention. However, all ports were successfully treated, and no surgical intervention was required. The safety end points included minor or major hemorrhages, such as intracranial hemorrhages, or sepsis. Safety end points were determined by a 24 h follow-up telephone call. RESULTS: Of the 50 chest ports (30 single ports and 10 double ports) treated with alteplase, 36 required 2 mg (72%) and 14 required 4 mg (28%). The efficacy end point was 100% for all chest ports treated, without any adverse events. CONCLUSION: High efficacy and safety rates of restoring function in occluded chest ports were obtained with 2 mg or 4 mg doses of alteplase. Part of this high efficacy rate may be due to the gentle push and pull technique used in the present study. PMID:22477414

  14. Multi-cored vortices support function of slotted wing tips of birds in gliding and flapping flight

    PubMed Central

    2017-01-01

    Slotted wing tips of birds are commonly considered an adaptation to improve soaring performance, despite their presence in species that neither soar nor glide. We used particle image velocimetry to measure the airflow around the slotted wing tip of a jackdaw (Corvus monedula) as well as in its wake during unrestrained flight in a wind tunnel. The separated primary feathers produce individual wakes, confirming a multi-slotted function, in both gliding and flapping flight. The resulting multi-cored wingtip vortex represents a spreading of vorticity, which has previously been suggested as indicative of increased aerodynamic efficiency. Considering benefits of the slotted wing tips that are specific to flapping flight combined with the wide phylogenetic occurrence of this configuration, we propose the hypothesis that slotted wings evolved initially to improve performance in powered flight. PMID:28539482

  15. Modulating p56Lck in T-Cells by a Chimeric Peptide Comprising Two Functionally Different Motifs of Tip from Herpesvirus saimiri

    PubMed Central

    Vernot, Jean-Paul; Perdomo-Arciniegas, Ana María; Pérez-Quintero, Luis Alberto; Martínez, Diego Fernando

    2015-01-01

    The Lck interacting protein Tip of Herpesvirus saimiri is responsible for T-cell transformation both in vitro and in vivo. Here we designed the chimeric peptide hTip-CSKH, comprising the Lck specific interacting motif CSKH of Tip and its hydrophobic transmembrane sequence (hTip), the latter as a vector targeting lipid rafts. We found that hTip-CSKH can induce a fivefold increase in proliferation of human and Aotus sp. T-cells. Costimulation with PMA did not enhance this proliferation rate, suggesting that hTip-CSKH is sufficient and independent of further PKC stimulation. We also found that human Lck phosphorylation was increased earlier after stimulation when T-cells were incubated previously with hTip-CSKH, supporting a strong signalling and proliferative effect of the chimeric peptide. Additionally, Lck downstream signalling was evident with hTip-CSKH but not with control peptides. Importantly, hTip-CSKH could be identified in heavy lipid rafts membrane fractions, a compartment where important T-cell signalling molecules (LAT, Ras, and Lck) are present during T-cell activation. Interestingly, hTip-CSKH was inhibitory to Jurkat cells, in total agreement with the different signalling pathways and activation requirements of this leukemic cell line. These results provide the basis for the development of new compounds capable of modulating therapeutic targets present in lipid rafts. PMID:26539553

  16. Modulating p56Lck in T-Cells by a Chimeric Peptide Comprising Two Functionally Different Motifs of Tip from Herpesvirus saimiri.

    PubMed

    Vernot, Jean-Paul; Perdomo-Arciniegas, Ana María; Pérez-Quintero, Luis Alberto; Martínez, Diego Fernando

    2015-01-01

    The Lck interacting protein Tip of Herpesvirus saimiri is responsible for T-cell transformation both in vitro and in vivo. Here we designed the chimeric peptide hTip-CSKH, comprising the Lck specific interacting motif CSKH of Tip and its hydrophobic transmembrane sequence (hTip), the latter as a vector targeting lipid rafts. We found that hTip-CSKH can induce a fivefold increase in proliferation of human and Aotus sp. T-cells. Costimulation with PMA did not enhance this proliferation rate, suggesting that hTip-CSKH is sufficient and independent of further PKC stimulation. We also found that human Lck phosphorylation was increased earlier after stimulation when T-cells were incubated previously with hTip-CSKH, supporting a strong signalling and proliferative effect of the chimeric peptide. Additionally, Lck downstream signalling was evident with hTip-CSKH but not with control peptides. Importantly, hTip-CSKH could be identified in heavy lipid rafts membrane fractions, a compartment where important T-cell signalling molecules (LAT, Ras, and Lck) are present during T-cell activation. Interestingly, hTip-CSKH was inhibitory to Jurkat cells, in total agreement with the different signalling pathways and activation requirements of this leukemic cell line. These results provide the basis for the development of new compounds capable of modulating therapeutic targets present in lipid rafts.

  17. Analyte concentration at the tip of a nanopipette.

    PubMed

    Calander, Nils

    2009-10-15

    Concentration of molecules within the tips of nanopipettes when applying a DC voltage is herein investigated using finite-element simulations. The ion concentrations and fluxes due to diffusion, electro-migration, and electro-osmotic flow, and the electric potential are determined by the simultaneous solution of the Nernst-Planck, Poisson, and Navier-Stokes equations within the water solution containing sodium and chloride ions and negatively charged molecules. The electric potential within the pipette glass wall is at the same time determined by the Poisson equation together with appropriate boundary conditions and accounts for a field effect through the wall. Fixed negative surface charge on both the internal and external glass surfaces of the nanopipette is included together with the field effect through the glass wall to account for the electric double layer and the electro-osmosis. The inclusion of the field effect through the pipette wall is new compared to previous modeling of similar structures and is shown to be crucial for the behavior at the tip. It is demonstrated that the concentration of molecules is a consequence of ionic charge accumulation at the tip screening the electric field, thereby slowing down the electrophoretic motion of the molecules, which is further slowed down or stopped by the oppositely directed electro-osmosis. It is also shown that the trapping is very sensitive to the properties of the molecule, that is, its electrophoretic mobility and diffusion coefficient, the properties of the pipette, the ionic strength of the solution, and the applied electric field.

  18. Hard-tip, soft-spring lithography.

    PubMed

    Shim, Wooyoung; Braunschweig, Adam B; Liao, Xing; Chai, Jinan; Lim, Jong Kuk; Zheng, Gengfeng; Mirkin, Chad A

    2011-01-27

    Nanofabrication strategies are becoming increasingly expensive and equipment-intensive, and consequently less accessible to researchers. As an alternative, scanning probe lithography has become a popular means of preparing nanoscale structures, in part owing to its relatively low cost and high resolution, and a registration accuracy that exceeds most existing technologies. However, increasing the throughput of cantilever-based scanning probe systems while maintaining their resolution and registration advantages has from the outset been a significant challenge. Even with impressive recent advances in cantilever array design, such arrays tend to be highly specialized for a given application, expensive, and often difficult to implement. It is therefore difficult to imagine commercially viable production methods based on scanning probe systems that rely on conventional cantilevers. Here we describe a low-cost and scalable cantilever-free tip-based nanopatterning method that uses an array of hard silicon tips mounted onto an elastomeric backing. This method-which we term hard-tip, soft-spring lithography-overcomes the throughput problems of cantilever-based scanning probe systems and the resolution limits imposed by the use of elastomeric stamps and tips: it is capable of delivering materials or energy to a surface to create arbitrary patterns of features with sub-50-nm resolution over centimetre-scale areas. We argue that hard-tip, soft-spring lithography is a versatile nanolithography strategy that should be widely adopted by academic and industrial researchers for rapid prototyping applications.

  19. Investigation on tip enhanced Raman spectra of graphene

    NASA Astrophysics Data System (ADS)

    Li, Xinjuan; Liu, Yanqi; Zeng, Zhuo; Wang, Peijie; Fang, Yan; Zhang, Lisheng

    2018-02-01

    Tip-enhanced Raman scattering (TERS) is a promising analytical approach for some two-dimensional materials and offers the possibility to correlate imaging and chemical data. Tip-enhanced Raman spectra of graphene are discussed in some details, including substrate, gap between tip-apex and sample surface as well as Ag-nanowire. The TERS spectra give special emphasis to the possibility of TERS tip to induce a large number of defects only while got the tip attached to sample surface. Then the dependence of the TERS spectra of graphene and gap between the probe tip and sample surface was studied, and distribution features of electromagnetic (EM) field around tip were also simulated by finite-difference time-domain (FDTD). The Raman signal enhancement of graphene was further discussed with respect to experimental data. Furthermore, the Ag-nanowire as a nano-antenna could significantly enhance the weak Raman signal of D-band of monolayer graphene is shown, and the TERS spectra of graphene with regard to different regions of Ag-nanowires (endpoints, body) were obtained toward investigating into the distribution of electromagnetic field.

  20. Endoscopic management of occluded metal biliary stents: metal versus 10F plastic stents.

    PubMed

    Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin

    2010-11-14

    To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS.

  1. Advanced optical blade tip clearance measurement system

    NASA Technical Reports Server (NTRS)

    Ford, M. J.; Honeycutt, R. E.; Nordlund, R. E.; Robinson, W. W.

    1978-01-01

    An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

  2. Results of the combined U.S. Multicenter Pivotal Study and the Continuing Access Study of the Nit-Occlud PDA device for percutaneous closure of patent ductus arteriosus.

    PubMed

    Moore, John W; Greene, Jessica; Palomares, Salvadore; Javois, Alexander; Owada, Carl Y; Cheatham, John P; Hoyer, Mark H; Jones, Thomas K; Levi, Daniel S

    2014-12-01

    This study aimed to compare the efficacy and safety of the Nit-Occlud PDA device (PFM Medical, Cologne, Germany) to benchmarks designed as objective performance criteria (OPC). The Nit-Occlud PDA is a nitinol coil-type patent ductus arteriosus (PDA) occluder with a reverse cone configuration, which is implanted using a controlled delivery system. Patients with <4-mm minimum diameter PDA were prospectively enrolled in the Pivotal and the Continuing Access Studies from 15 sites in the United States and were followed up for 12 months post-procedure. Investigator-reported outcomes were compared to OPC including a composite success criterion, efficacy criteria of successful closure (clinical and echocardiographic), and safety criteria incidence of adverse events (serious and of total). The Pivotal Study enrolled patients between November 1, 2002 and October 31, 2005, and the Continuing Access Study enrolled additional patients between September 1, 2006 and October 31, 2007. A total of 357 patients were enrolled, and 347 had successful device implantations. After 12 months, 96.8% had complete echocardiographic closure (OPC = 85%) and 98.1% had clinical closure (OPC = 95%). There were no deaths or serious adverse events (OPC = 1%). The total adverse event rate was 4.7% (OPC = 6%). Composite success was 95.1% in the study patients (OPC = 80%). Closure of small- and medium-sized PDA with the Nit-Occlud PDA is effective and safe when compared with OPC. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Technology Tips

    ERIC Educational Resources Information Center

    Santos-Trigo, Manuel

    2004-01-01

    A dynamic program for geometry called Cabri Geometry II is used to examine properties of figures like triangles and make connections with other mathematical ideas like ellipse. The technology tip includes directions for creating such a problem with technology and suggestions for exploring it.

  4. Quasi-linearly polarized hybrid modes in tapered and metal-coated tips with circular apertures: understanding the functionality of aperture tips

    NASA Astrophysics Data System (ADS)

    Tugchin, B. N.; Janunts, N.; Steinert, M.; Dietrich, K.; Kley, E. B.; Tünnermann, A.; Pertsch, T.

    2017-06-01

    In this study, we investigate analytically and experimentally the roles of quasi-linearly polarized (LP), hybrid, plasmonic and photonic modes in optical detection and excitation with aperture tips in scanning near-field optical microscopy. Aperture tips are tapered and metal-coated optical fibers where small circular apertures are made at the apex. In aperture tips, there exist plasmonic modes that are bound at the interface of the metal cladding to the inner dielectric fiber and photonic modes that are guided in the area of the increased index in the dielectric fiber core. The fundamental photonic mode, although excited by the free-space Gaussian beam, experiences cutoff and turns into an evanescent mode. The photonic mode also becomes lossier than the plasmonic mode toward the tip aperture, and its power decay due to absorption and reflection is expected to be at least 10-9. In contrast, the fundamental plasmonic mode has no cutoff and thus reaches all the way to the tip aperture. Due to the non-adiabaticity of both modes’ propagations through the taper below a core radius of 600 nm, there occurs coupling between the modes. The transmission efficiency of the plasmonic mode, including the coupling efficiency and the propagation loss, is expected to be about 10-6 that is at least 3 orders of magnitude larger than that of the photonic mode. Toward the tip aperture, the longitudinal field of the photonic mode becomes stronger than the transverse ones while the transverse fields always dominate for the plasmonic mode. Experimentally, we obtain polarization resolved images of the near-field at the tip aperture and compare with the x- and y-components of the fundamental quasi-LP plasmonic and photonic modes. The results show that not only the pattern but also the intensity ratios of the x- and y-components of the aperture near-field match with that of the fundamental plasmonic mode. Consequently, we conclude that only the plasmonic mode reaches the tip aperture and

  5. Coral Reef Resilience, Tipping Points and the Strength of Herbivory

    PubMed Central

    Holbrook, Sally J.; Schmitt, Russell J.; Adam, Thomas C.; Brooks, Andrew J.

    2016-01-01

    Coral reefs increasingly are undergoing transitions from coral to macroalgal dominance. Although the functional roles of reef herbivores in controlling algae are becoming better understood, identifying possible tipping points in the herbivory-macroalgae relationships has remained a challenge. Assessment of where any coral reef ecosystem lies in relation to the coral-to-macroalgae tipping point is fundamental to understanding resilience properties, forecasting state shifts, and developing effective management practices. We conducted a multi-year field experiment in Moorea, French Polynesia to estimate these properties. While we found a sharp herbivory threshold where macroalgae escape control, ambient levels of herbivory by reef fishes were well above that needed to prevent proliferation of macroalgae. These findings are consistent with previously observed high resilience of the fore reef in Moorea. Our approach can identify vulnerable coral reef systems in urgent need of management action to both forestall shifts to macroalgae and preserve properties essential for resilience. PMID:27804977

  6. Hawkmoths evaluate scenting flowers with the tip of their proboscis

    PubMed Central

    Haverkamp, Alexander; Yon, Felipe; Keesey, Ian W; Mißbach, Christine; Koenig, Christopher; Hansson, Bill S; Baldwin, Ian T

    2016-01-01

    Pollination by insects is essential to many ecosystems. Previously, we have shown that floral scent is important to mediate pollen transfer between plants (Kessler et al., 2015). Yet, the mechanisms by which pollinators evaluate volatiles of single flowers remained unclear. Here, Nicotiana attenuata plants, in which floral volatiles have been genetically silenced and its hawkmoth pollinator, Manduca sexta, were used in semi-natural tent and wind-tunnel assays to explore the function of floral scent. We found that floral scent functions to increase the fitness of individual flowers not only by increasing detectability but also by enhancing the pollinator's foraging efforts. Combining proboscis choice tests with neurophysiological, anatomical and molecular analyses we show that this effect is governed by newly discovered olfactory neurons on the tip of the moth's proboscis. With the tip of their tongue, pollinators assess the advertisement of individual flowers, an ability essential for maintaining this important ecosystem service. DOI: http://dx.doi.org/10.7554/eLife.15039.001 PMID:27146894

  7. Coral Reef Resilience, Tipping Points and the Strength of Herbivory.

    PubMed

    Holbrook, Sally J; Schmitt, Russell J; Adam, Thomas C; Brooks, Andrew J

    2016-11-02

    Coral reefs increasingly are undergoing transitions from coral to macroalgal dominance. Although the functional roles of reef herbivores in controlling algae are becoming better understood, identifying possible tipping points in the herbivory-macroalgae relationships has remained a challenge. Assessment of where any coral reef ecosystem lies in relation to the coral-to-macroalgae tipping point is fundamental to understanding resilience properties, forecasting state shifts, and developing effective management practices. We conducted a multi-year field experiment in Moorea, French Polynesia to estimate these properties. While we found a sharp herbivory threshold where macroalgae escape control, ambient levels of herbivory by reef fishes were well above that needed to prevent proliferation of macroalgae. These findings are consistent with previously observed high resilience of the fore reef in Moorea. Our approach can identify vulnerable coral reef systems in urgent need of management action to both forestall shifts to macroalgae and preserve properties essential for resilience.

  8. TIPS Evaluation Project Retrospective Study: Wave 1 and 2.

    ERIC Educational Resources Information Center

    Hubbard, Susan M.; Mulvey, Kevin P.

    2003-01-01

    Measured substance abuse treatment professionals' knowledge, attitudes, and practices regarding the Treatment Improvement Protocol (TIP) series and the 28 TIPs. Results for 3,267 respondents in wave 1 and 1,028 in wave 2 indicate that almost half of all professionals were aware of the TIPs. Attitudes toward TIPs were positive, but professionals…

  9. Advanced ceramic material for high temperature turbine tip seals

    NASA Technical Reports Server (NTRS)

    Vogan, J. W.; Solomon, N. G.; Stetson, A. R.

    1980-01-01

    Forty-one material systems were evaluated for potential use in turbine blade tip seal applications at 1370 C. Both ceramic blade tip inserts and abradable ceramic tip shoes were tested. Hot gas erosion, impact resistance, thermal stability, and dynamic rub performance were the criteria used in rating the various materials. Silicon carbide and silicon nitride were used, both as blade tips and abradables. The blade tip inserts were fabricated by hot pressing while low density and honeycomb abradables were sintered or reaction bonded.

  10. Needle tip localization using stylet vibration.

    PubMed

    Harmat, Adam; Rohling, Robert N; Salcudean, Septimiu E

    2006-09-01

    Power Doppler ultrasound is used to localize the tip of a needle by detecting physical vibrations. Two types of vibrations are investigated, lateral and axial. The lateral vibrations are created by rotating a stylet, whose tip is slightly bent, inside a stationary cannula while the stylet is completely within the cannula. The minute deflection at the needle tip when rotated causes tissue motion. The axial vibration is induced by extending and retracting a straight stylet inside a stationary cannula. The stylet's tip makes contact with the tissue and causes it to move. The lateral vibration method was found to perform approximately the same under a variety of configurations (e.g., different insertion angles and depths) and better than the axial vibration method. Tissue stiffness affects the performance of the lateral vibration method, but good images can be obtained through proper tuning of the ultrasound machine.

  11. Extended Glauert tip correction to include vortex rollup effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maniaci, David; Schmitz, Sven

    Wind turbine loads predictions by blade-element momentum theory using the standard tip-loss correction have been shown to over-predict loading near the blade tip in comparison to experimental data. This over-prediction is theorized to be due to the assumption of light rotor loading, inherent in the standard tip-loss correction model of Glauert. A higher- order free-wake method, WindDVE, is used to compute the rollup process of the trailing vortex sheets downstream of wind turbine blades. Results obtained serve an exact correction function to the Glauert tip correction used in blade-element momentum methods. Lastly, it is found that accounting for the effectsmore » of tip vortex rollup within the Glauert tip correction indeed results in improved prediction of blade tip loads computed by blade-element momentum methods.« less

  12. Extended Glauert tip correction to include vortex rollup effects

    DOE PAGES

    Maniaci, David; Schmitz, Sven

    2016-10-03

    Wind turbine loads predictions by blade-element momentum theory using the standard tip-loss correction have been shown to over-predict loading near the blade tip in comparison to experimental data. This over-prediction is theorized to be due to the assumption of light rotor loading, inherent in the standard tip-loss correction model of Glauert. A higher- order free-wake method, WindDVE, is used to compute the rollup process of the trailing vortex sheets downstream of wind turbine blades. Results obtained serve an exact correction function to the Glauert tip correction used in blade-element momentum methods. Lastly, it is found that accounting for the effectsmore » of tip vortex rollup within the Glauert tip correction indeed results in improved prediction of blade tip loads computed by blade-element momentum methods.« less

  13. Fabrication of a trimer/single atom tip for gas field ion sources by means of field evaporation without tip heating.

    PubMed

    Kim, Kwang-Il; Kim, Young Heon; Ogawa, Takashi; Choi, Suji; Cho, Boklae; Ahn, Sang Jung; Park, In-Yong

    2018-05-11

    A gas field ion source (GFIS) has many advantages that are suitable for ion microscope sources, such as high brightness and a small virtual source size, among others. In order to apply a tip-based GFIS to an ion microscope, it is better to create a trimer/single atom tip (TSAT), where the ion beam must be generated in several atoms of the tip apex. Here, unlike the conventional method which uses tip heating or a reactive gas, we show that the tip surface can be cleaned using only the field evaporation phenomenon and that the TSAT can also be fabricated using an insulating layer containing tungsten oxide, which remains after electrochemical etching. Using this method, we could get TSAT over 90% of yield. Copyright © 2018. Published by Elsevier B.V.

  14. Multi-cored vortices support function of slotted wing tips of birds in gliding and flapping flight.

    PubMed

    KleinHeerenbrink, Marco; Johansson, L Christoffer; Hedenström, Anders

    2017-05-01

    Slotted wing tips of birds are commonly considered an adaptation to improve soaring performance, despite their presence in species that neither soar nor glide. We used particle image velocimetry to measure the airflow around the slotted wing tip of a jackdaw ( Corvus monedula ) as well as in its wake during unrestrained flight in a wind tunnel. The separated primary feathers produce individual wakes, confirming a multi-slotted function, in both gliding and flapping flight. The resulting multi-cored wingtip vortex represents a spreading of vorticity, which has previously been suggested as indicative of increased aerodynamic efficiency. Considering benefits of the slotted wing tips that are specific to flapping flight combined with the wide phylogenetic occurrence of this configuration, we propose the hypothesis that slotted wings evolved initially to improve performance in powered flight. © 2017 The Author(s).

  15. A deforestation-induced tipping point for the South American monsoon system.

    PubMed

    Boers, Niklas; Marwan, Norbert; Barbosa, Henrique M J; Kurths, Jürgen

    2017-01-25

    The Amazon rainforest has been proposed as a tipping element of the earth system, with the possibility of a dieback of the entire ecosystem due to deforestation only of parts of the rainforest. Possible physical mechanisms behind such a transition are still subject to ongoing debates. Here, we use a specifically designed model to analyse the nonlinear couplings between the Amazon rainforest and the atmospheric moisture transport from the Atlantic to the South American continent. These couplings are associated with a westward cascade of precipitation and evapotranspiration across the Amazon. We investigate impacts of deforestation on the South American monsoonal circulation with particular focus on a previously neglected positive feedback related to condensational latent heating over the rainforest, which strongly enhances atmospheric moisture inflow from the Atlantic. Our results indicate the existence of a tipping point. In our model setup, crossing the tipping point causes precipitation reductions of up to 40% in non-deforested parts of the western Amazon and regions further downstream. The responsible mechanism is the breakdown of the aforementioned feedback, which occurs when deforestation reduces transpiration to a point where the available atmospheric moisture does not suffice anymore to release the latent heat needed to maintain the feedback.

  16. A deforestation-induced tipping point for the South American monsoon system

    PubMed Central

    Boers, Niklas; Marwan, Norbert; Barbosa, Henrique M. J.; Kurths, Jürgen

    2017-01-01

    The Amazon rainforest has been proposed as a tipping element of the earth system, with the possibility of a dieback of the entire ecosystem due to deforestation only of parts of the rainforest. Possible physical mechanisms behind such a transition are still subject to ongoing debates. Here, we use a specifically designed model to analyse the nonlinear couplings between the Amazon rainforest and the atmospheric moisture transport from the Atlantic to the South American continent. These couplings are associated with a westward cascade of precipitation and evapotranspiration across the Amazon. We investigate impacts of deforestation on the South American monsoonal circulation with particular focus on a previously neglected positive feedback related to condensational latent heating over the rainforest, which strongly enhances atmospheric moisture inflow from the Atlantic. Our results indicate the existence of a tipping point. In our model setup, crossing the tipping point causes precipitation reductions of up to 40% in non-deforested parts of the western Amazon and regions further downstream. The responsible mechanism is the breakdown of the aforementioned feedback, which occurs when deforestation reduces transpiration to a point where the available atmospheric moisture does not suffice anymore to release the latent heat needed to maintain the feedback. PMID:28120928

  17. A deforestation-induced tipping point for the South American monsoon system

    NASA Astrophysics Data System (ADS)

    Boers, Niklas; Marwan, Norbert; Barbosa, Henrique M. J.; Kurths, Jürgen

    2017-01-01

    The Amazon rainforest has been proposed as a tipping element of the earth system, with the possibility of a dieback of the entire ecosystem due to deforestation only of parts of the rainforest. Possible physical mechanisms behind such a transition are still subject to ongoing debates. Here, we use a specifically designed model to analyse the nonlinear couplings between the Amazon rainforest and the atmospheric moisture transport from the Atlantic to the South American continent. These couplings are associated with a westward cascade of precipitation and evapotranspiration across the Amazon. We investigate impacts of deforestation on the South American monsoonal circulation with particular focus on a previously neglected positive feedback related to condensational latent heating over the rainforest, which strongly enhances atmospheric moisture inflow from the Atlantic. Our results indicate the existence of a tipping point. In our model setup, crossing the tipping point causes precipitation reductions of up to 40% in non-deforested parts of the western Amazon and regions further downstream. The responsible mechanism is the breakdown of the aforementioned feedback, which occurs when deforestation reduces transpiration to a point where the available atmospheric moisture does not suffice anymore to release the latent heat needed to maintain the feedback.

  18. Electrohydrodynamic and flow induced tip-streaming

    NASA Astrophysics Data System (ADS)

    Collins, Robert

    2008-11-01

    A liquid subjected to a strong electric field emits thin fluid jets from conical structures (Taylor cones) that form at its surface. Such behavior has both practical and fundamental implications, e.g. for raindrops in thunderclouds and in electrospray mass spectrometry. Theoretical analysis of the temporal development of such electrohydrodynamic (EHD) tip- streaming phenomena has been elusive given the large disparity in length scales between the macroscopic drops/films and the microscopic (nanoscopic) jets. Here, simulation and experiment are used to investigate the mechanisms of EHD tip-streaming from a film of finite conductivity. In the simulations, the full Taylor-Melcher leaky-dielectric model, which accounts for charge relaxation, is solved. Simulations show that tip- streaming does not occur for perfectly conducting or perfectly insulating liquids. Scaling laws for sizes of drops produced from the breakup of the thin jets is developed. Further, simulations demonstrate the critical role played by electrically induced surface shear stresses in the inception of tip-streaming. This invites a comparison to flow focusing, i.e. tip-streaming induced by co-flowing two fluids. The latter phenomenon is also investigated by simulation. In collaboration with Ronald Suryo, Exxon-Mobil; and Jeremy Jones, Michael Harris, and Osman Basaran, Purdue University.

  19. Transonic rotor tip design using numerical optimization

    NASA Technical Reports Server (NTRS)

    Tauber, Michael E.; Langhi, Ronald G.

    1985-01-01

    The aerodynamic design procedure for a new blade tip suitable for operation at transonic speeds is illustrated. For the first time, 3 dimensional numerical optimization was applied to rotor tip design, using the recent derivative of the ROT22 code, program R22OPT. Program R22OPT utilized an efficient quasi-Newton optimization algorithm. Multiple design objectives were specified. The delocalization of the shock wave was to be eliminated in forward flight for an advance ratio of 0.41 and a tip Mach number of 0.92 at psi = 90 deg. Simultaneously, it was sought to reduce torque requirements while maintaining effective restoring pitching moments. Only the outer 10 percent of the blade span was modified; the blade area was not to be reduced by more than 3 percent. The goal was to combine the advantages of both sweptback and sweptforward blade tips. A planform that featured inboard sweepback was combined with a sweptforward tip and a taper ratio of 0.5. Initially, the ROT22 code was used to find by trial and error a planform geometry which met the design goals. This configuration had an inboard section with a leading edge sweep of 20 deg and a tip section swept forward at 25 deg; in addition, the airfoils were modified.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maleux, Geert; Pirenne, Jacques; Vaninbroukx, Johan

    Our purpose was to assess the feasibility of orthotopic liver transplantation (OLT) in patients priorly having undergone transjugular intrahepatic portosystemic shunt (TIPS) with an expanded tetrafluoroethylene (e-PTFE)-covered endoprosthesis. In 48 patients an e- PTFE-covered endoprosthesis was inserted to treat severe complications of portal hypertension. In 36 patients the endoprosthesis was inserted during TIPS creation (de novo TIPS); in the other 12 patients the endoprosthesis was placed to repermeabilize the previously created, but occluded bare stent (revision TIPS). Eight of them (5 de novo and 3 revision cases) later underwent an OLT. The hospital records of these patients were reviewed frommore » initial admission, through TIPS, the pre-OLT period, and OLT to current postoperative status. Five de novo and 3 revision cases underwent OLT 4-279 days (mean delay: 80.8 days) after TIPS procedure. All OLT's were performed under veno-venous bypass surgery. De visu surgical inspection confirmed correct positioning of the fully patent stent graft, starting in the portal vein and ending at the junction of the hepatic vein to the inferior caval vein. No surgical difficulty was observed during proximal or distal clamping or during resection of the diseased liver. Correctly positioned e-PTFE-covered nitinol endoprostheses do not interfere with a later OLT and may not be considered as a contraindication in patients who need a TIPS as a bridge to OLT.« less

  1. Magnetic elements for switching magnetization magnetic force microscopy tips.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cambel, V.; Elias, P.; Gregusova, D.

    2010-09-01

    Using combination of micromagnetic calculations and magnetic force microscopy (MFM) imaging we find optimal parameters for novel magnetic tips suitable for switching magnetization MFM. Switching magnetization MFM is based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within the technique the sum of the scanned data with reversed tip magnetization depicts local atomic forces, while their difference maps the local magnetic forces. Here we propose the design and calculate the magnetic properties of tips suitable for this scanning probe technique. We find that for best performance the spin-polarized tips must exhibit low magnetic moment, lowmore » switching fields, and single-domain state at remanence. The switching field of such tips is calculated and optimum shape of the Permalloy elements for the tips is found. We show excellent correspondence between calculated and experimental results for Py elements.« less

  2. Management of occluded metal stents in malignant biliary obstruction: similar outcomes with second metal stents compared to plastic stents

    PubMed Central

    Shah, Tilak; Desai, Svetang; Haque, Mahfuzul; Dakik, Hassan; Fisher, Deborah

    2013-01-01

    Background Covered or uncovered self expandable metallic stents (SEMS) placed in patients with malignant biliary obstruction can occlude in 19–40%, but optimal management is unclear. Aim We sought to summarize current evidence regarding management of occluded SEMS in patients with malignant biliary obstruction. Methods Two investigators independently searched Pubmed, Embase, and Web of Science using pre-defined search criteria, and reviewed bibliographies of included studies. Data were independently abstracted by two investigators, and analyzed using RevMan. We compared strategies of second SEMS versus plastic stents with respect to the following outcomes: rate of second stent re-occlusion, duration of second stent patency, and survival. Results Ten retrospective studies met inclusion criteria for the systematic review. Management options described were placement of an uncovered SEMS (n=125), covered SEMS (n=106), plastic stent (n=135), percutaneous biliary drain (n=7), mechanical cleaning (n=18), or microwave coagulation (n=7). Relative risk of re-occlusion was not significantly different in patients with second SEMS compared to plastic stents (RR 1.24, 95% CI 0.92, 1.67, I2= 0, p 0.16). Duration of second stent patency was not significantly different between patients who received second SEMS versus plastic stents (weighted mean difference 0.46, 95% CI −0.30, 1.23, I2=83%). Survival was not significantly different among patients who received plastic stents versus SEMS (weighted mean difference −1.13, 95% CI −2.33, 0.07, I2 86%, p 0.07). Conclusions Among patients with malignant biliary obstruction and occluded SEMS, available evidence suggests a strategy of placing a plastic stent may be as effective as second SEMS. Limitations of these findings were that all studies were retrospective and heterogeneity between studies was detected for two of the outcomes. PMID:22732833

  3. News: Tripping over tipping points/elements

    EPA Science Inventory

    The term “tipping point” has been used to identify a critical threshold susceptible to a tiny perturbation that can qualitatively alter the state or development of a system. “Tipping element” has been introduced to describe large-scale components of the Earth system that may pass...

  4. Observations from varying the lift and drag inputs to a noise prediction method for supersonic helical tip speed propellers

    NASA Technical Reports Server (NTRS)

    Dittmar, J. H.

    1984-01-01

    Previous comparisons between calculated and measured supersonic helical tip speed propeller noise show them to have different trends of peak blade passing tone versus helical tip Mach number. It was postulated that improvements in this comparison could be made first by including the drag force terms in the prediction and then by reducing the blade lift terms at the tip to allow the drag forces to dominate the noise prediction. Propeller hub to tip lift distributions were varied, but they did not yield sufficient change in the predicted lift noise to improve the comparison. This result indicates that some basic changes in the theory may be needed. In addition, the noise predicted by the drag forces did not exhibit the same curve shape as the measured data. So even if the drag force terms were to dominate, the trends with helical tip Mach number for theory and experiment would still not be the same. The effect of the blade shock wave pressure rise was approxmated by increasing the drag coefficient at the blade tip. Predictions using this shock wdave approximation did have a curve shape similar to the measured data. This result indicates that the shock pressure rise probably controls the noise at supersonic tip speed and that the linear prediction method can give the proper noise trend with Mach number.

  5. Ecohydrology and tipping points in semiarid australian rangelands

    NASA Astrophysics Data System (ADS)

    Saco, P. M.; Azadi, S.; Moreno de las Heras, M.; Willgoose, G. R.

    2017-12-01

    Semiarid landscapes are often characterised by a spatially heterogeneous vegetation cover forming mosaics of patches with dense vegetation within bare soil. This patchy vegetation cover, which is linked to the healthy function of these ecosystems, is sensitive to human disturbances that can lead to degradation. Previous work suggests that vegetation loss below a critical value can lead to a sudden decrease in landscape functionality following threshold behaviour. The decrease in vegetation cover is linked to erosion and substantial water losses by increasing landscape hydrological connectivity. We study these interactions and the possible existence of tipping points in the Mulga land bioregion, by combining remote sensing observations and results from an eco-geomorphologic model to investigate changes in ecosystem connectivity and the existence of threshold behaviour. More than 30 sites were selected along a precipitation gradient spanning a range from approximately 250 to 500 mm annual rainfall. The analysis of vegetation patterns is derived from high resolution remote sensing images (IKONOS, QuickBird, Pleiades) and MODIS NDVI, which combined with local precipitation data is used to compute rainfall use efficiency to assess the ecosystem function. A critical tipping point associated to loss of vegetation cover appears in the sites with lower annual precipitation. We found that this tipping point behaviour decreases for sites with higher rainfall. We use the model to investigate the relation between structural and functional connectivity and the emergence of threshold behaviour for selected plots along this precipitation gradient. Both observations and modelling results suggest that sites with higher rainfall are more resilient to changes in surface connectivity. The implications for ecosystem resilience and land management are discussed

  6. Twelve Tips for Effective Electronic Presentation.

    ERIC Educational Resources Information Center

    Crosby, Joy

    1994-01-01

    Offers 12 tips for effective electronic presentation. This article is intended for readers who may be considering using electronic presentation for the first time. Offers reasons for its popularity and occasions when it may be used. The tips offer assistance in the design and presentation of electronic material. (LZ)

  7. Bed Bug Tips

    EPA Pesticide Factsheets

    How to deal with bed bugs in one printable page. Ten tips include ensuring correct insect identification, reducing clutter, understand integrated pest management, using mattress and box spring encasements, and heat treatment.

  8. Low Vision Tips

    MedlinePlus

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  9. Fiber-optic laser Doppler turbine tip clearance probe

    NASA Astrophysics Data System (ADS)

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 μm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades.

  10. Fiber-optic laser Doppler turbine tip clearance probe.

    PubMed

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 microm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades.

  11. Time-of-Flight Tip-Clearance Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, H. S.; Kurkov, A. P.; Janetzke, D. C.

    1999-01-01

    In this paper a time-of-flight probe system incorporating the two integrated fiber optic probes which are tilted equally relative to the probe holder centerline, is applied for the first time to measure the tip clearance of an advanced fan prototype. Tip clearance is largely independent of the signal amplitude and it relies on timing measurement. This work exposes optical effects associated with the fan blade stagger angle that were absent during the original spin-rig experiment on the zero stagger rotor. Individual blade tip clearances were measured with accuracy of +/- 127-mm (+/- 0.005-in). Probe features are discussed and improvements to the design are suggested.

  12. Tips for Reducing Pesticide Impacts on Wildlife

    EPA Pesticide Factsheets

    This Web page provides tips for pesticide users in residential and agricultural settings, as well as tips for certified pesticide applicators for ways to protect wildlife from potentially harmful effects of pesticides.

  13. Endoscopic management of occluded metal biliary stents: Metal versus 10F plastic stents

    PubMed Central

    Yoon, Won Jae; Ryu, Ji Kon; Lee, Jung Won; Ahn, Dong-Won; Kim, Yong-Tae; Yoon, Yong Bum; Woo, Sang Myung; Lee, Woo Jin

    2010-01-01

    AIM: To compare the efficacy of self-expandable metal stents (SEMSs) with 10F plastic stents (PSs) in the endoscopic management of occluded SEMSs. METHODS: We retrospectively reviewed the medical records of 56 patients who underwent SEMS insertion for palliation of unresectable malignant biliary obstruction between 2000 and 2007 and subsequent endoscopic retrograde biliary drainage (ERBD) with SEMS or PS for initial SEMS occlusion between 2000 and 2008. RESULTS: Subsequent ERBD with SEMS was performed in 29 patients and with PS in 27. The median time to stent occlusion after subsequent ERBD was 186 d in the SEMS group and 101 d in the PS group (P = 0.118). Overall median stent patency was 79 d for the SEMS group and 66 d for the PS group (P = 0.379). The mean number of additional biliary drainage procedures after subsequent ERBD in patients that died (n = 50) during the study period was 2.54 ± 4.12 for the SEMS group and 1.85 ± 1.95 for the PS group (P = 0.457). The mean total cost of additional biliary drainage procedures after the occlusion of subsequent SEMS or PS was $410.04 ± 692.60 for the SEMS group and $630.16 ± 671.63 for the PS group (P = 0.260). Tumor ingrowth as the cause of initial SEMS occlusion was the only factor associated with a shorter time to subsequent stent occlusion (101 d for patients with tumor ingrowth vs 268 d for patients without tumor ingrowth, P = 0.008). CONCLUSION: Subsequent ERBD with PSs offered similar patency and number of additional biliary drainage procedures compared to SEMSs in the management of occluded SEMS. PMID:21072899

  14. Ten Fire Safety Tips for Schools.

    ERIC Educational Resources Information Center

    Lake, James D.

    1999-01-01

    Provides 10 basic tips, compiled from the National Fire Protection Association's Life Safety Code 101, to ensure that educational facilities are fire safe. Tips include use of frequent and unexpected fire drills, limiting wall space of student artwork and teaching materials, being alert to preventing arson, planning speedy and safe emergency…

  15. The influence of tip shape on bending force during needle insertion

    PubMed Central

    van de Berg, Nick J.; de Jong, Tonke L.; van Gerwen, Dennis J.; Dankelman, Jenny; van den Dobbelsteen, John J.

    2017-01-01

    Steering of needles involves the planning and timely modifying of instrument-tissue force interactions to allow for controlled deflections during the insertion in tissue. In this work, the effect of tip shape on these forces was studied using 10 mm diameter needle tips. Six different tips were selected, including beveled and conical versions, with or without pre-bend or pre-curve. A six-degree-of-freedom force/torque sensor measured the loads during indentations in tissue simulants. The increased insertion (axial) and bending (radial) forces with insertion depth — the force-displacement slopes — were analyzed. Results showed that the ratio between radial and axial forces was not always proportional. This means that the tip load does not have a constant orientation, as is often assumed in mechanics-based steering models. For all tip types, the tip-load assumed a more radial orientation with increased axial load. This effect was larger for straight tips than for pre-bent or pre-curved tips. In addition, the force-displacement slopes were consistently higher for (1) increased tip angles, and for (2) beveled tips compared to conical tips. Needles with a bent or curved tip allow for an increased bending force and a decreased variability of the tip load vector orientation. PMID:28074939

  16. Nasal tip support: A finite element analysis of the role of the caudal septum during tip depression

    PubMed Central

    Manuel, Cyrus T.; Leary, Ryan; Protsenko, Dmitriy E.; Wong, Brian J.F.

    2014-01-01

    Objective/Hypothesis Although minor and major tip support mechanisms have been described in detail, no quantitative models exist to provide support for the relative contributions of the structural properties of the major alar cartilage, the fibrous attachments to surrounding structures, and the rigid support structures in an objective manner. Study Design The finite element method was used to compute the stress distribution in the nose during simple tip compression, and then identify the specific anatomic structures that resist deformation and thus contribute to “tip support”. Additionally, the impact of caudal septal resection on nasal tip support was examined. Method The computer models consisted of three tissue components with anatomically correct geometries for skin and bone derived from CT data. Septum, upper lateral cartilages, and major alar cartilages were fitted within the model using 3D CAD software. 5mm nasal tip compression was performed on the models with caudal septal resection (3mm and 5 mm) and without resection to simulate palpation, then the resulting spatial distribution of stress and displacement was calculated. Results The von Mises stress in the normal model was primarily concentrated along medial crural angle. As caudal septum length was reduced, stress was redistributed to adjacent soft tissue and bone, resulting in less force acting on the septum. In all models, displacement was greatest near the intermediate crura. Conclusions These models are the first step in the comprehensive mechanical analysis of nasal tip dynamics. Our model supports the concept of the caudal septum and major alar cartilage as providing the majority of critical load-bearing support. Level of Evidence N/A PMID:23878007

  17. Invited Review Article: Tip modification methods for tip-enhanced Raman spectroscopy (TERS) and colloidal probe technique: A 10 year update (2006-2016) review

    NASA Astrophysics Data System (ADS)

    Yuan, C. C.; Zhang, D.; Gan, Y.

    2017-03-01

    Engineering atomic force microscopy tips for reliable tip enhanced Raman spectroscopy (TERS) and colloidal probe technique are becoming routine practices in many labs. In this 10 year update review, various new tip modification methods developed over the past decade are briefly reviewed to help researchers select the appropriate method. The perspective is put in a large context to discuss the opportunities and challenges in this area, including novel combinations of seemingly different methods, potential applications of some methods which were not originally intended for TERS tip fabrication, and the problems of high cost and poor reproducibility of tip fabrication.

  18. Propeller noise caused by blade tip radial forces

    NASA Technical Reports Server (NTRS)

    Hanson, D. B.

    1986-01-01

    New experimental evidence which indicates the presence of leading edge and tip edge vortex flow on Prop-Fans is examined, and performance and noise consequences are addressed. It was shown that the tip edge vortex is a significant noise source, particularly for unswept Prop-Fan blades. Preliminary calculations revealed that the addition of the tip side edge source to single rotation Prop-Fans during take off conditions improved the agreement between experiment and theory at blade passing frequency. At high-speed conditions such as the Prop-Fan cruise point, the tip loading effect tends to cancel thickness noise.

  19. Characterization of the interaction between AFM tips and surface nanobubbles.

    PubMed

    Walczyk, Wiktoria; Schönherr, Holger

    2014-06-24

    While the presence of gaseous enclosures observed at various solid-water interfaces, the so-called "surface nanobubles", has been confirmed by many groups in recent years, their formation, properties, and stability have not been convincingly and exhaustively explained. Here we report on an atomic force microscopy (AFM) study of argon nanobubbles on highly oriented pyrolitic graphite (HOPG) in water to elucidate the properties of nanobubble surfaces and the mechanism of AFM tip-nanobubble interaction. In particular, the deformation of the nanobubble-water interface by the AFM tip and the question whether the AFM tip penetrates the nanobubble during scanning were addressed by this combined intermittent contact (tapping) mode and force volume AFM study. We found that the stiffness of nanobubbles was smaller than the cantilever spring constant and comparable with the surface tension of water. The interaction with the AFM tip resulted in severe quasi-linear deformation of the bubbles; however, in the case of tip-bubble attraction, the interface deformed toward the tip. We tested two models of tip-bubble interaction, namely, the capillary force and the dynamic interaction model, and found, depending on the tip properties, good agreement with experimental data. The results showed that the tip-bubble interaction strength and the magnitude of the bubble deformation depend strongly on tip and bubble geometry and on tip and substrate material, and are very sensitive to the presence of contaminations that alter the interfacial tension. In particular, nanobubbles interacted differently with hydrophilic and hydrophobic AFM tips, which resulted in qualitatively and quantitatively different force curves measured on the bubbles in the experiments. To minimize bubble deformation and obtain reliable AFM results, nanobubbles must be measured with a sharp hydrophilic tip and with a cantilever having a very low spring constant in a contamination-free system.

  20. Predicting casualties implied by TIPs

    NASA Astrophysics Data System (ADS)

    Trendafiloski, G.; Wyss, M.; Wyss, B. M.

    2009-12-01

    When an earthquake is predicted, forecast, or expected with a higher than normal probability, losses are implied. We estimated the casualties (fatalities plus injured) that should be expected if earthquakes in TIPs (locations of Temporarily Increased Probability of earthquakes) defined by Kossobokov et al. (2009) should occur. We classified the predictions of losses into the categories red (more than 400 fatalities or more than 1,000 injured), yellow (between 100 and 400 fatalities), green (fewer than 100 fatalities), and gray (undetermined). TIPs in Central Chile, the Philippines, Papua, and Taiwan are in the red class, TIPs in Southern Sumatra, Nicaragua, Vanatu, and Honshu in the yellow class, and TIPs in Tonga, Loyalty Islands, Vanatu, S. Sandwich Islands, Banda Sea, and the Kuriles, are classified as green. TIPs where the losses depend moderately on the assumed point of major energy release were classified as yellow; TIPs such as in the Talaud Islands and in Tonga, where the losses depend very strongly on the location of the epicenter, were classified as gray. The accuracy of loss estimates after earthquakes with known hypocenter and magnitude are affected by uncertainties in transmission and soil properties, the composition of the building stock, the population present, and the method by which the numbers of casualties are calculated. In the case of TIPs, uncertainties in magnitude and location are added, thus we calculate losses for a range of these two parameters. Therefore, our calculations can only be considered order of magnitude estimates. Nevertheless, our predictions can come to within a factor of two of the observed numbers, as in the case of the M7.6 earthquake of October 2005 in Pakistan that resulted in 85,000 fatalities (Wyss, 2005). In subduction zones, the geometrical relationship between the earthquake source capable of a great earthquake and the population is clear because there is only one major fault plane available, thus the epicentral

  1. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems.

    PubMed

    Tomassini, R; Rossi, G; Brouckaert, J-F

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  2. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    NASA Astrophysics Data System (ADS)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  3. Parametric analysis of swept-wing geometry with sheared wing tips

    NASA Technical Reports Server (NTRS)

    Fremaux, C. M.; Vijgen, P. M. H. W.; Van Dam, C. P.

    1990-01-01

    A computational parameter study is presented of potential reductions in induced drag and increases in lateral-directional stability due to sheared wing tips attached to an untwisted wing of moderate sweep and aspect ratio. Sheared tips are swept and tapered wing-tip devices mounted in the plane of the wing. The induced-drag results are obtained using an inviscid, incompressible surface-panel method that models the nonlinear effects due to the deflected and rolled-up wake behind the lifting surface. The induced-drag results with planar sheared tips are compared to straight-tapered tip extensions and nonplanar winglet geometries. The lateral-directional static-stability characteristics of the wing with sheared tips are estimated using a quasi-vortex-lattice method. For certain combinations of sheared-tip sweep and taper, both the induced efficiency of the wing and the relevant static-stability derivatives are predicted to increase compared to the wing with a straight-tapered tip modification.

  4. Fiber optic muzzle brake tip for reducing fiber burnback and stone retropulsion during thulium fiber laser lithotripsy.

    PubMed

    Hutchens, Thomas C; Gonzalez, David A; Irby, Pierce B; Fried, Nathaniel M

    2017-01-01

    The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A “fiber muzzle brake” was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 ?? ? s , and 300 Hz using a 100 - ? m -core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560 - ? m -outer-diameter, 360 - ? m -inner-diameter tube with a 275 - ? m -diameter through hole located 250 ?? ? m from the distal end. The fiber tip was recessed a distance of 500 ?? ? m . Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40 ± 4 ?? mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25 ± 4 ?? s

  5. Diabetes: Dental Tips

    MedlinePlus

    Diabetes: Dental Tips For more copies contact: National Institute of Dental and Craniofacial Research National Oral Health Information Clearinghouse ... damage the gum and bone that hold your teeth in place and may lead to painful chewing ...

  6. Root tips moving through soil

    PubMed Central

    Curlango-Rivera, Gilberto

    2011-01-01

    Root elongation occurs by the generation of new cells from meristematic tissue within the apical 1–2 mm region of root tips. Therefore penetration of the soil environment is carried out by newly synthesized plant tissue, whose cells are inherently vulnerable to invasion by pathogens. This conundrum, on its face, would seem to reflect an intolerable risk to the successful establishment of root systems needed for plant life. Yet root tip regions housing the meristematic tissues repeatedly have been found to be free of microbial infection and colonization. Even when spore germination, chemotaxis, and/or growth of pathogens are stimulated by signals from the root tip, the underlying root tissue can escape invasion. Recent insights into the functions of root border cells, and the regulation of their production by transient exposure to external signals, may shed light on long-standing observations. PMID:21455030

  7. Regulation of Histone Acetyltransferase TIP60 Function by Histone Deacetylase 3

    PubMed Central

    Yi, Jingjie; Huang, Xiangyang; Yang, Yuxia; Zhu, Wei-Guo; Gu, Wei; Luo, Jianyuan

    2014-01-01

    The key member of the MOZ (monocyticleukaemia zinc finger protein), Ybf2/Sas3, Sas2, and TIP60 acetyltransferases family, Tat-interactive protein, 60 kD (TIP60), tightly modulates a wide array of cellular processes, including chromatin remodeling, gene transcription, apoptosis, DNA repair, and cell cycle arrest. The function of TIP60 can be regulated by SIRT1 through deacetylation. Here we found that TIP60 can also be functionally regulated by HDAC3. We identified six lysine residues as its autoacetylation sites. Mutagenesis of these lysines to arginines completely abolishes the autoacetylation of TIP60. Overexpression of HDAC3 increases TIP60 ubiquitination levels. However, unlike SIRT1, HDAC3 increased the half-life of TIP60. Further study found that HDAC3 colocalized with TIP60 both in the nucleus and the cytoplasm, which could be the reason why HDAC3 can stabilize TIP60. The deacetylation of TIP60 by both SIRT1 and HDAC3 reduces apoptosis induced by DNA damage. Knockdown of HDAC3 in cells increased TIP60 acetylation levels and increased apoptosis after DNA damage. Together, our findings provide a better understanding of TIP60 regulation mechanisms, which is a significant basis for further studies of its cellular functions. PMID:25301942

  8. Turbine-blade tip clearance and tip timing measurements using an optical fiber bundle sensor

    NASA Astrophysics Data System (ADS)

    Garcia, Iker; Beloki, Josu; Zubia, Joseba; Durana, Gaizka; Aldabaldetreku, Gotzon

    2013-04-01

    Traditional limitations of capacitive, inductive or discharging probe sensor for tip timing and tip clearance measurements are overcome by reflective intensity modulated optical fiber sensors. This paper presents the signals and results corresponding to a one stage turbine rig which rotor has 146 blades, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on turbine casing. It is composed of a central illuminating fiber that guides the light from a laser to the turbine blade, and two concentric rings of receiving fibers that collect the reflected light. Two photodetectors turn this reflected light signal from the receiving rings into voltage. The electrical signals are acquired and saved by a high-sample-rate oscilloscope. In tip clearance calculations the ratio of the signals provided by each ring of receiving fibers is evaluated and translated into distance. In the case of tip timing measurements, only one of the signals is considered to get the arrival time of the blade. The differences between the real and theoretical arrival times of the blades are used to obtain the deflections amplitude. The system provides the travelling wave spectrum, which presents the average vibration amplitude of the blades at a certain nodal diameter. The reliability of the results in the turbine rig testing facilities suggests the possibility of performing these measurements in real turbines under real working conditions.

  9. Prediction of Unshsrouded Rotor Blade Tip Heat Transfer

    NASA Technical Reports Server (NTRS)

    Ameri, A. A.; Steinthorsson, E.

    1994-01-01

    The rate of heat transfer on the tip of a turbine rotor blade and on the blade surface in the vicinity of the tip, was successfully predicted. The computations were performed with a multiblock computer code which solves the Reynolds Averaged Navier-Stokes equations using an efficient multigrid method. The case considered for the present calculations was the Space Shuttle Main Engine (SSME) high pressure fuel side turbine. The predictions of the blade tip heat transfer agreed reasonably well with the experimental measurements using the present level of grid refinement. On the tip surface, regions with high rate of heat transfer was found to exist close to the pressure side and suction side edges. Enhancement of the heat transfer was also observed on the blade surface near the tip. Further comparison of the predictions was performed with results obtained from correlations based on fully developed channel flow.

  10. Relocalization of human chromatin remodeling cofactor TIP48 in mitosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sigala, Barbara; Edwards, Mina; Puri, Teena

    2005-11-01

    TIP48 is a highly conserved eukaryotic AAA{sup +} protein which is an essential cofactor for several complexes involved in chromatin acetylation and remodeling, transcriptional and developmental regulation and nucleolar organization and trafficking. We show that TIP48 abundance in HeLa cells did not change during the cell cycle, nor did its distribution in various biochemical fractions. However, we observed distinct changes in the subcellular localization of TIP48 during M phase using immunofluorescence microscopy. Our studies demonstrate that in interphase cells TIP48 was found mainly in the nucleus and exhibited a distinct localization in the nuclear periphery. As the cells entered mitosis,more » TIP48 was excluded from the condensing chromosomes but showed association with the mitotic apparatus. During anaphase, some TIP48 was detected in the centrosome colocalizing with tubulin but the strongest staining appeared in the mitotic equator associated with the midzone central spindle. Accumulation of TIP48 in the midzone and the midbody was observed in late telophase and cytokinesis. This redeployment of TIP48 during anaphase and cytokinesis was independent of microtubule assembly. The relocation of endogenous TIP48 to the midzone/midbody under physiological conditions suggests a novel and distinct function for TIP48 in mitosis and possible involvement in the exit of mitosis.« less

  11. Method of cooling gas only nozzle fuel tip

    DOEpatents

    Bechtel, William Theodore; Fitts, David Orus; DeLeonardo, Guy Wayne

    2002-01-01

    A diffusion flame nozzle gas tip is provided to convert a dual fuel nozzle to a gas only nozzle. The nozle tip diverts compressor discharge air from the passage feeding the diffusion nozzle air swirl vanes to a region vacated by removal of the dual fuel components, so that the diverted compressor discharge air can flow to and through effusion holes in the end cap plate of the nozzle tip. In a preferred embodiment, the nozzle gas tip defines a cavity for receiving the compressor discharge air from a peripheral passage of the nozzle for flow through the effusion openings defined in the end cap plate.

  12. A review of turbine blade tip heat transfer.

    PubMed

    Bunker, R S

    2001-05-01

    This paper presents a review of the publicly available knowledge base concerning turbine blade tip heat transfer, from the early fundamental research which laid the foundations of our knowledge, to current experimental and numerical studies utilizing engine-scaled blade cascades and turbine rigs. Focus is placed on high-pressure, high-temperature axial-turbine blade tips, which are prevalent in the majority of today's aircraft engines and power generating turbines. The state of our current understanding of turbine blade tip heat transfer is in the transitional phase between fundamentals supported by engine-based experience, and the ability to a priori correctly predict and efficiently design blade tips for engine service.

  13. Wind-tunnel test of an articulated helicopter rotor model with several tip shapes

    NASA Technical Reports Server (NTRS)

    Berry, J. D.; Mineck, R. E.

    1980-01-01

    Six interchangeable tip shapes were tested: a square (baseline) tip, an ogee tip, a subwing tip, a swept tip, a winglet tip, and a short ogee tip. In hover at the lower rotational speeds the swept, ogee, and short ogee tips had about the same torque coefficient, and the subwing and winglet tips had a larger torque coefficient than the baseline square tip blades. The ogee and swept tip blades required less torque coefficient at lower rotational speeds and roughly equivalent torque coefficient at higher rotational speeds compared with the baseline square tip blades in forward flight. The short ogee tip required higher torque coefficient at higher lift coefficients than the baseline square tip blade in the forward flight test condition.

  14. User's manual for PEPSIG NASA tip vortex version

    NASA Technical Reports Server (NTRS)

    Tsai, Tommy M.; Dejong, Frederick J.; Levy, Ralph

    1988-01-01

    The tip vortex flowfield plays a significant role in the performance of advanced aircraft propellers. The flowfield in the tip region is complex, three-dimensional and viscous with large secondary velocities. A computer code was developed to predict the tip vortex flowfield of advanced aircraft propellers. This document is the user's manual. The analysis and a series of test cases are presented in NASA-CR-182179.

  15. Tip-enhanced Raman spectroscopy of lipid bilayers in water with an alumina- and silver-coated tungsten tip.

    PubMed

    Nakata, Atsushi; Nomoto, Tomonori; Toyota, Taro; Fujinami, Masanori

    2013-01-01

    Tip-enhanced Raman spectroscopy (TERS) of supported phospholipid bilayers in an aqueous environment is discussed in this paper. Two bilayer membranes were examined: 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) and 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC). We fabricated alumina- and silver-coated tungsten tips that are very robust in water. There was a large time-dependence in the TERS spectra for the DOPC bilayers, whereas no such time-dependence was observed in the DPPC bilayer spectra under the probe tip. The spectral changes of DOPC bilayers are discussed in terms of the fluidity of the liquid crystalline phase. Time-resolved TERS thus has the potential to characterize inhomogeneity and diffusion in fluidic phospholipid bilayer membranes.

  16. Thulium fiber laser lithotripsy using small spherical distal fiber tips

    NASA Astrophysics Data System (ADS)

    Wilson, Christopher R.; Hardy, Luke A.; Kennedy, Joshua D.; Irby, Pierce B.; Fried, Nathaniel M.

    2016-02-01

    This study tests a 100-μm-core fiber with 300-μm-diameter ball tip during Thulium fiber laser (TFL) lithotripsy. The TFL was operated at 1908 nm wavelength with 35-mJ pulse energy, 500-μs pulse duration, and 300-Hz pulse rate. Calcium oxalate/phosphate stone samples were weighed, laser procedure times measured, and ablation rates calculated for ball tip fibers, with comparison to bare tip fibers. Photographs of ball tips were taken before and after each procedure to observe ball tip degradation and determine number of procedures completed before need to replace fiber. Saline irrigation rates and ureteroscope deflection were measured with and without TFL fiber present. There was no statistical difference (P > 0.05) between stone ablation rates for single-use ball tip fiber (1.3 +/- 0.4 mg/s) (n=10), multiple-use ball tip fiber (1.3 +/- 0.5 mg/s) (n=44), and conventional single-use bare tip fibers (1.3 +/- 0.2 mg/s) (n=10). Ball tip durability varied widely, but fibers averaged > 4 stone procedures before decline in stone ablation rates due to mechanical damage at front surface of ball tip. The small fiber diameter did not impact ureteroscope deflection or saline flow rates. The miniature ball tip fiber may provide a cost-effective design for safe fiber insertion through the ureteroscope working channel and the ureter without risk of scope damage or tissue perforation, and without compromising stone ablation efficiency during TFL ablation of kidney stones.

  17. Evaluation of the tip-bending response in clinically used endoscopes.

    PubMed

    Rozeboom, Esther D; Reilink, Rob; Schwartz, Matthijs P; Fockens, Paul; Broeders, Ivo A M J

    2016-04-01

    Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses.

  18. Excitation of surface plasmons in Al-coated SNOM tips

    NASA Astrophysics Data System (ADS)

    Palm, Viktor; Rähn, Mihkel; Jäme, Joonas; Hizhnyakov, Vladimir

    2012-10-01

    The mesoscopic effect of spectral modulation occurring due to the interference of two photonic fiber modes filtered out by a metal-coated SNOM tip is used to observe the surface plasmon polariton (SPP) excitation in SNOM tips. In a spectrum of the broadband light transmitted by a SNOM tip a region of highly regular spectral modulation can be found, indicating the spectral interval in which only two photonic modes (apparently HE11 and TM01) are transmitted with significant and comparable amplitudes. The modulation period yields the value of optical path difference (OPD) for this pair of modes. Due to the multimode fiber's inherent modal dispersion, this OPD value depends linearly on the fiber tail length l. An additional contribution to OPD can be generated in a metal-coated SNOM tip due to a mode-dependent photon-plasmon coupling strength resulting in generation of SPPs with different propagation velocities. For an Al-coated 200 nm SNOM tip spectra of transmitted light have been registered for ten different l values. An extrapolation of the linear OPD (l) dependence to l=0 yields a significant residual OPD value, indicating according to our theoretical considerations a mode-selective SPP excitation in the metal-coated tip. The modal dispersion is shown to switch its sign in the SNOM tip. First results of analogous experiments with an Al-coated 150 nm SNOM tip confirm our conclusions.

  19. Fibre tip pH sensor for tumor detection during surgery

    NASA Astrophysics Data System (ADS)

    Henderson, Matthew R.; Schartner, Erik P.; Callen, David F.; Gill, P. Grantley; Monro, Tanya M.

    2015-05-01

    Surgery on tumours commonly involves a lumpectomy method, where a section of tissue containing the tumour is removed, to improve cosmetic outcomes and quality of life. Following surgery, the margins of the removed section are checked by pathology tests to ensure that the entire tumour has been removed. Unfortunately, approximately 15-20% of margins show incomplete removal and require a subsequent operation to remove the remaining tumour. Tumour detection during surgery could allow the removed section to be enlarged appropriately, reducing the likelihood of requiring subsequent surgery. A change in the extracellular pH in the vicinity of a tumour, when compared to normal tissue, has been shown previously in literature. We have fabricated an optical fibre tip pH sensor by embedding a fluorophore within a photopolymerised acrylamide polymer on the tip of a 200 micron diameter silica fibre. Preliminary measurements of human melanoma samples have shown a significant difference in the measured pH values between tumour and normal tissue. This demonstration paves to way to highly accurate margin detection during surgery.

  20. The African Origin of Complex Projectile Technology: An Analysis Using Tip Cross-Sectional Area and Perimeter

    PubMed Central

    Sisk, Matthew L.; Shea, John J.

    2011-01-01

    Despite a body of literature focusing on the functionality of modern and stylistically distinct projectile points, comparatively little attention has been paid to quantifying the functionality of the early stages of projectile use. Previous work identified a simple ballistics measure, the Tip Cross-Sectional Area, as a way of determining if a given class of stone points could have served as effective projectile armatures. Here we use this in combination with an alternate measure, the Tip Cross-Sectional Perimeter, a more accurate proxy of the force needed to penetrate a target to a lethal depth. The current study discusses this measure and uses it to analyze a collection of measurements from African Middle Stone Age pointed stone artifacts. Several point types that were rejected in previous studies are statistically indistinguishable from ethnographic projectile points using this new measure. The ramifications of this finding for a Middle Stone Age origin of complex projectile technology is discussed. PMID:21755048

  1. Wettability of AFM tip influences the profile of interfacial nanobubbles

    NASA Astrophysics Data System (ADS)

    Teshima, Hideaki; Takahashi, Koji; Takata, Yasuyuki; Nishiyama, Takashi

    2018-02-01

    To accurately characterize the shape of interfacial nanobubbles using atomic force microscopy (AFM), we investigated the effect of wettability of the AFM tip while operating in the peak force tapping (PFT) mode. The AFM tips were made hydrophobic and hydrophilic by Teflon AF coating and oxygen plasma treatment, respectively. It was found that the measured base radius of nanobubbles differed between AFM height images and adhesion images, and that this difference depended on the tip wettability. The force curves obtained during the measurements were also different depending on the wettability, especially in the range of the tip/nanobubble interaction and in the magnitude of the maximum attractive force in the retraction period. The difference suggests that hydrophobic tips penetrate the gas/liquid interface of the nanobubbles, with the three phase contact line being pinned on the tip surface; hydrophilic tips on the other hand do not penetrate the interface. We then quantitatively estimated the pinning position and recalculated the true profiles of the nanobubbles by comparing the height images and adhesion images. As the AFM tip was made more hydrophilic, the penetration depth decreased and eventually approached zero. This result suggests that the PFT measurement using a hydrophilic tip is vital for the acquisition of reliable nanobubble profiles.

  2. Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stasek, Josef, E-mail: stasek@fnhk.c; Lojik, Miroslav; Bis, Josef

    2009-05-15

    We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotid stent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, themore » effect persists.« less

  3. Kaplan turbine tip vortex cavitation - analysis and prevention

    NASA Astrophysics Data System (ADS)

    Motycak, L.; Skotak, A.; Kupcik, R.

    2012-11-01

    The work is focused on one type of Kaplan turbine runner cavitation - a tip vortex cavitation. For detailed description of the tip vortex, the CFD analysis is used. On the basis of this analysis it is possible to estimate the intensity of cavitating vortex core, danger of possible blade surface and runner chamber cavitation pitting. In the paper, the ways how to avoid the pitting effect of the tip vortex are described. In order to prevent the blade surface against pitting, the following possibilities as the change of geometry of the runner blade, dimension of tip clearance and finally the installation of the anti-cavitation lips are discussed. The knowledge of the shape and intensity of the tip vortex helps to design the anti-cavitation lips more sophistically. After all, the results of the model tests of the Kaplan runner with or without anti-cavitation lips and the results of the CFD analysis are compared.

  4. Nonlinear Aerodynamics and the Design of Wing Tips

    NASA Technical Reports Server (NTRS)

    Kroo, Ilan

    1991-01-01

    The analysis and design of wing tips for fixed wing and rotary wing aircraft still remains part art, part science. Although the design of airfoil sections and basic planform geometry is well developed, the tip regions require more detailed consideration. This is important because of the strong impact of wing tip flow on wing drag; although the tip region constitutes a small portion of the wing, its effect on the drag can be significant. The induced drag of a wing is, for a given lift and speed, inversely proportional to the square of the wing span. Concepts are proposed as a means of reducing drag. Modern computational methods provide a tool for studying these issues in greater detail. The purpose of the current research program is to improve the understanding of the fundamental issues involved in the design of wing tips and to develop the range of computational and experimental tools needed for further study of these ideas.

  5. Pressure-induced transformations in glassy water: A computer simulation study using the TIP4P/2005 model

    NASA Astrophysics Data System (ADS)

    Wong, Jessina; Jahn, David A.; Giovambattista, Nicolas

    2015-08-01

    We study the pressure-induced transformations between low-density amorphous (LDA) and high-density amorphous (HDA) ice by performing out-of-equilibrium molecular dynamics (MD) simulations. We employ the TIP4P/2005 water model and show that this model reproduces qualitatively the LDA-HDA transformations observed experimentally. Specifically, the TIP4P/2005 model reproduces remarkably well the (i) structure (OO, OH, and HH radial distribution functions) and (ii) densities of LDA and HDA at P = 0.1 MPa and T = 80 K, as well as (iii) the qualitative behavior of ρ(P) during compression-induced LDA-to-HDA and decompression-induced HDA-to-LDA transformations. At the rates explored, the HDA-to-LDA transformation is less pronounced than in experiments. By studying the LDA-HDA transformations for a broad range of compression/decompression temperatures, we construct a "P-T phase diagram" for glassy water that is consistent with experiments and remarkably similar to that reported previously for ST2 water. This phase diagram is not inconsistent with the possibility of TIP4P/2005 water exhibiting a liquid-liquid phase transition at low temperatures. A comparison with previous MD simulation studies of SPC/E and ST2 water as well as experiments indicates that, overall, the TIP4P/2005 model performs better than the SPC/E and ST2 models. The effects of cooling and compression rates as well as aging on our MD simulations results are also discussed. The MD results are qualitatively robust under variations of cooling/compression rates (accessible in simulations) and are not affected by aging the hyperquenched glass for at least 1 μs. A byproduct of this work is the calculation of TIP4P/2005 water's diffusion coefficient D(T) at P = 0.1 MPa. It is found that, for T ≥ 210 K, D(T) ≈ (T - TMCT)-γ as predicted by mode coupling theory and in agreement with experiments. For TIP4P/2005 water, TMCT = 209 K and γ = 2.14, very close to the corresponding experimental values TMCT = 221 K

  6. Pressure-induced transformations in glassy water: A computer simulation study using the TIP4P/2005 model.

    PubMed

    Wong, Jessina; Jahn, David A; Giovambattista, Nicolas

    2015-08-21

    We study the pressure-induced transformations between low-density amorphous (LDA) and high-density amorphous (HDA) ice by performing out-of-equilibrium molecular dynamics (MD) simulations. We employ the TIP4P/2005 water model and show that this model reproduces qualitatively the LDA-HDA transformations observed experimentally. Specifically, the TIP4P/2005 model reproduces remarkably well the (i) structure (OO, OH, and HH radial distribution functions) and (ii) densities of LDA and HDA at P = 0.1 MPa and T = 80 K, as well as (iii) the qualitative behavior of ρ(P) during compression-induced LDA-to-HDA and decompression-induced HDA-to-LDA transformations. At the rates explored, the HDA-to-LDA transformation is less pronounced than in experiments. By studying the LDA-HDA transformations for a broad range of compression/decompression temperatures, we construct a "P-T phase diagram" for glassy water that is consistent with experiments and remarkably similar to that reported previously for ST2 water. This phase diagram is not inconsistent with the possibility of TIP4P/2005 water exhibiting a liquid-liquid phase transition at low temperatures. A comparison with previous MD simulation studies of SPC/E and ST2 water as well as experiments indicates that, overall, the TIP4P/2005 model performs better than the SPC/E and ST2 models. The effects of cooling and compression rates as well as aging on our MD simulations results are also discussed. The MD results are qualitatively robust under variations of cooling/compression rates (accessible in simulations) and are not affected by aging the hyperquenched glass for at least 1 μs. A byproduct of this work is the calculation of TIP4P/2005 water's diffusion coefficient D(T) at P = 0.1 MPa. It is found that, for T ≥ 210 K, D(T) ≈ (T - T(MCT))(-γ) as predicted by mode coupling theory and in agreement with experiments. For TIP4P/2005 water, T(MCT) = 209 K and γ = 2.14, very close to the corresponding experimental values T

  7. Theoretical Study of tip apex electronic structure in Scanning Tunneling Microscope

    NASA Astrophysics Data System (ADS)

    Choi, Heesung; Huang, Min; Randall, John; Cho, Kyeongjae

    2011-03-01

    Scanning Tunneling Microscope (STM) has been widely used to explore diverse surface properties with an atomic resolution, and STM tip has played a critical role in controlling surface structures. However, detailed information of atomic and electronic structure of STM tip and the fundamental understanding of STM images are still incomplete. Therefore, it is important to develop a comprehensive understanding of the electronic structure of STM tip. We have studied the atomic and electronic structures of STM tip with various transition metals (TMs) by DFT method. The d-electrons of TM tip apex atoms show different orbital states near the Fermi level. We will present comprehensive data of STM tips from our DFT calculation. Verified quantification of the tip electronic structures will lead to fundamental understanding of STM tip structure-property relationship. This work is supported by the DARPA TBN Program and the Texas ETF. DARPA Tip Based Nanofabrication Program and the Emerging Technology Fund of the State of Texas.

  8. 75 FR 26889 - Airworthiness Directives; Arrow Falcon Exporters, Inc. (previously Utah State University) et al...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-13

    ... the forward tip weight retention block (tip block) or aft tip closure (tip closure), loss of the blade...) forward tip weight retention block (tip block) and the aft tip closure (tip closure) for adhesive bond... prevent loss of a tip block or tip closure, loss of a blade, and subsequent loss of control of the...

  9. Evaluation of the tip-bending response in clinically used endoscopes

    PubMed Central

    Rozeboom, Esther D.; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo A. M. J.

    2016-01-01

    Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. Materials and methods: We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. Results: Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. Conclusion: This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses. PMID:27092330

  10. Immediate effects of the semi-occluded vocal tract exercise with LaxVox® tube in singers.

    PubMed

    Fadel, Congeta Bruniere Xavier; Dassie-Leite, Ana Paula; Santos, Rosane Sampaio; Santos, Celso Gonçalves Dos; Dias, Cláudio Antônio Sorondo; Sartori, Denise Jussara

    The purpose of this study was to analyze the immediate effects of the semi-occluded vocal tract exercise (SOVTE) using the LaxVox® tube in singers. Participants were 23 singers, classical singing students, aged 18 to 47 years (mean age = 27.2 years). First, data was collected through the application of a demographic questionnaire and the recording of sustained emission - vowel /ε/, counting 1-10, and a music section from the participants' current repertoire. After that, the participants were instructed and performed the SOVTE using the LaxVox® tube for three minutes. Finally, the same vocal samples were collected immediately after SOVTE performance and the singers responded to a questionnaire on their perception regarding vocal changes after the exercise. The vocal samples were analyzed by referees (speech-language pathologists and singing teachers) and by means of acoustic analysis. Most of the singers reported improved voice post-exercise in both tasks - speech and singing. Regarding the perceptual assessment (sustained vowel, speech, and singing), the referees found no difference between pre- and post-exercise emissions. The acoustic analysis of the sustained vowel showed increased Fundamental Frequency (F0) and reduction of the Glottal to Noise Excitation (GNE) ratio post-exercise. The semi-occluded vocal tract exercise with LaxVox® tube promotes immediate positive effects on the self-assessment and acoustic analysis of voice in professional singers without vocal complains. No immediate significant changes were observed with respect to auditory-perceptual evaluation of speech and singing.

  11. In situ scanning tunneling microscope tip treatment device for spin polarization imaging

    DOEpatents

    Li, An-Ping [Oak Ridge, TN; Jianxing, Ma [Oak Ridge, TN; Shen, Jian [Knoxville, TN

    2008-04-22

    A tip treatment device for use in an ultrahigh vacuum in situ scanning tunneling microscope (STM). The device provides spin polarization functionality to new or existing variable temperature STM systems. The tip treatment device readily converts a conventional STM to a spin-polarized tip, and thereby converts a standard STM system into a spin-polarized STM system. The tip treatment device also has functions of tip cleaning and tip flashing a STM tip to high temperature (>2000.degree. C.) in an extremely localized fashion. Tip coating functions can also be carried out, providing the tip sharp end with monolayers of coating materials including magnetic films. The device is also fully compatible with ultrahigh vacuum sample transfer setups.

  12. Final Technical Report: Electrohydrodynamic Tip Streaming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basaran, Osman

    2016-01-06

    When subjected to strong electric fields, liquid drops and films form conical tips and emit thin jets from their tips. Such electrodydrodynamic (EDH) tip streaming or cone-jetting phenomena, which are sometimes referred to as electrospraying, occur widely in nature, e.g., in ejection of streams of small charged drops from pointed tips of raindrops in thunderclouds, and technology, e.g., in electrospray mass spectrometry or electric field-driven solvent extraction. More recently, EHD cone-jetting has emerged as a powerful technique for direct printing of solar cells, micro- and nano- particle production, and microencapsulation for controlled release. In many of the aforementioned situations, ofmore » equal importance to the processes by which one drop disintegrates to form several drops are those by which (a) two drops come together and coalesce and (b) two drops are coupled to form a double droplet system (DDS) or a capillary switch (CS). the main objective of this research program is to advance through simulation, theory, and experiment the breakup, coalescence, and oscillatory dynamics of single and pairs of charged as well as uncharged drops.« less

  13. Quantification of holmium:YAG optical tip degradation

    NASA Astrophysics Data System (ADS)

    Mues, Adam C.; Teichman, Joel M. H.; Knudsen, Bodo E.

    2009-02-01

    The holmium:yttrium aluminum garnet (YAG) laser is the gold standard laser for intracorporeal lithotripsy. Optical fibers are utilized to transmit laser energy to the surface of a stone for fragmentation. During lithotripsy, fiber tip degradation (burn back) can occur. The exact mechanism for tip degradation and related factors are not completely understood, and have not been investigated. This characteristic is important because fiber burn back may affect diminish fragmentation efficiency, increase operative time, and increase cost due to the need for fiber replacement. We hypothesize that fiber tip degradation (burn back) varies amongst different commercially available holmium:YAG laser fibers.

  14. Tip Fence for Reduction of Lift-Generated Airframe Noise

    NASA Technical Reports Server (NTRS)

    Ross, James C. (Inventor); Storms, Bruce L. (Inventor)

    1998-01-01

    The present invention is directed toward a unique lift-generated noise reduction apparatus. This apparatus includes a plurality of tip fences that are secured to the trailing and leading assemblies of the high-lift system, as close as possible to the discontinuities where the vortices are most likely to form. In one embodiment, these tip fences are secured to some or all of the outboard and inboard tips of the wing slats and flaps. The tip fence includes a generally flat, or an aerodynamically shaped plate or device that could be formed of almost any rigid material, such as metal, wood, plastic, fiber glass, aluminum, etc. In a preferred embodiment, the tip fences extend below and perpendicularly to flaps and the slats to which they are attached, such that these tip fences are aligned with the nominal free stream velocity of the aircraft. In addition to reducing airframe noise, the tip fence tends to decrease drag and to increase lift, thus improving the overall aerodynamic performance of the aircraft. Another advantage presented by the tip fence lies in the simplicity of its design, its elegance, and its ready ability to fit on the wing components, such as the flaps and the slats. Furthermore, it does not require non-standard materials or fabrication techniques, and it can be readily, easily and inexpensively retrofited on most of the existing aircraft, with minimal design changes.

  15. Biophysics and clinical utility of irrigated-tip radiofrequency catheter ablation.

    PubMed

    Houmsse, Mahmoud; Daoud, Emile G

    2012-01-01

    Catheter ablation by radiofrequency (RF) energy has successfully eliminated cardiac tachyarrhythmias. RF ablation lesions are created by thermal energy. Electrode catheters with 4-mm-tips have been adequate to ablate arrhythmias located near the endocardium; however, the 4-mm-tip electrode does not readily ablate deeper tachyarrhythmia substrate. With 8- and 10-mm-tip RF electrodes, ablation lesions were larger; yet, these catheters are associated with increased risk for coagulum, char and thrombus formation, as well as myocardial steam rupture. Cooled-tip catheter technology was designed to cool the electrode tip, prevent excessive temperatures at the electrode tip-tissue interface, and thus allow continued delivery of RF current into the surrounding tissue. This ablation system creates larger and deeper ablation lesions and minimizes steam pops and thrombus formation. The purpose of this article is to review cooled-tip RF ablation biophysics and outcomes of clinical studies as well as to discuss future technological improvements.

  16. Evaluation of cutting efficiency of ultrasonic tips used in orthograde endodontic treatment.

    PubMed

    Lin, Yu-Heng; Mickel, André K; Jones, Jefferson J; Montagnese, Thomas A; González, Alvaro F

    2006-04-01

    The purpose of the present study was to evaluate the cutting efficiency of the three different ultrasonic tips for orthograde endodontic treatment: stainless steel, zirconium nitride-coated, and diamond-coated tips. An ultrasonic handpiece was mounted on a custom-made automated balance, and each tip repeatedly penetrated dental stone blocks to a depth of 3 mm for 10 times. The amount of time taken to penetrate 3 mm of stone was measured. The diamond-coated tips showed significantly greater cutting efficiency than either stainless steel tips or zirconium-nitride coated tips. The stainless steel tips showed initial better cutting efficiency, but over time , there is no significant difference between the cutting efficiency of the stainless steel tips and the zirconium nitride coated tips. The diamond coated tips were the only group that showed breakage in this study.

  17. Computation of the tip vortex flowfield for advanced aircraft propellers

    NASA Technical Reports Server (NTRS)

    Tsai, Tommy M.; Dejong, Frederick J.; Levy, Ralph

    1988-01-01

    The tip vortex flowfield plays a significant role in the performance of advanced aircraft propellers. The flowfield in the tip region is complex, three-dimensional and viscous with large secondary velocities. An analysis is presented using an approximate set of equations which contains the physics required by the tip vortex flowfield, but which does not require the resources of the full Navier-Stokes equations. A computer code was developed to predict the tip vortex flowfield of advanced aircraft propellers. A grid generation package was developed to allow specification of a variety of advanced aircraft propeller shapes. Calculations of the tip vortex generation on an SR3 type blade at high Reynolds numbers were made using this code and a parametric study was performed to show the effect of tip thickness on tip vortex intensity. In addition, calculations of the tip vortex generation on a NACA 0012 type blade were made, including the flowfield downstream of the blade trailing edge. Comparison of flowfield calculations with experimental data from an F4 blade was made. A user's manual was also prepared for the computer code (NASA CR-182178).

  18. Identification and functional analysis of endothelial tip cell-enriched genes.

    PubMed

    del Toro, Raquel; Prahst, Claudia; Mathivet, Thomas; Siegfried, Geraldine; Kaminker, Joshua S; Larrivee, Bruno; Breant, Christiane; Duarte, Antonio; Takakura, Nobuyuki; Fukamizu, Akiyoshi; Penninger, Josef; Eichmann, Anne

    2010-11-11

    Sprouting of developing blood vessels is mediated by specialized motile endothelial cells localized at the tips of growing capillaries. Following behind the tip cells, endothelial stalk cells form the capillary lumen and proliferate. Expression of the Notch ligand Delta-like-4 (Dll4) in tip cells suppresses tip cell fate in neighboring stalk cells via Notch signaling. In DLL4(+/-) mouse mutants, most retinal endothelial cells display morphologic features of tip cells. We hypothesized that these mouse mutants could be used to isolate tip cells and so to determine their genetic repertoire. Using transcriptome analysis of retinal endothelial cells isolated from DLL4(+/-) and wild-type mice, we identified 3 clusters of tip cell-enriched genes, encoding extracellular matrix degrading enzymes, basement membrane components, and secreted molecules. Secreted molecules endothelial-specific molecule 1, angiopoietin 2, and apelin bind to cognate receptors on endothelial stalk cells. Knockout mice and zebrafish morpholino knockdown of apelin showed delayed angiogenesis and reduced proliferation of stalk cells expressing the apelin receptor APJ. Thus, tip cells may regulate angiogenesis via matrix remodeling, production of basement membrane, and release of secreted molecules, some of which regulate stalk cell behavior.

  19. Theoretical study of carbon-based tips for scanning tunnelling microscopy.

    PubMed

    González, C; Abad, E; Dappe, Y J; Cuevas, J C

    2016-03-11

    Motivated by recent experiments, we present here a detailed theoretical analysis of the use of carbon-based conductive tips in scanning tunnelling microscopy. In particular, we employ ab initio methods based on density functional theory to explore a graphitic, an amorphous carbon and two diamond-like tips for imaging with a scanning tunnelling microscope (STM), and we compare them with standard metallic tips made of gold and tungsten. We investigate the performance of these tips in terms of the corrugation of the STM images acquired when scanning a single graphene sheet. Moreover, we analyse the impact of the tip-sample distance and show that it plays a fundamental role in the resolution and symmetry of the STM images. We also explore in depth how the adsorption of single atoms and molecules in the tip apexes modifies the STM images and demonstrate that, in general, it leads to an improved image resolution. The ensemble of our results provides strong evidence that carbon-based tips can significantly improve the resolution of STM images, as compared to more standard metallic tips, which may open a new line of research in scanning tunnelling microscopy.

  20. The inviscid pressure field on the tip of a semi-infinite wing and its application to the formation of a tip vortex

    NASA Technical Reports Server (NTRS)

    Hall, G. F.; Shamroth, S. J.; Mcdonald, H.; Briley, W. R.

    1976-01-01

    A method was developed for determining the aerodynamic loads on the tip of an infinitely thin, swept, cambered semi-infinite wing at an angle of attack which is operating subsonically in an inviscid medium and is subjected to a sinusoidal gust. Under the assumption of linearized aerodynamics, the loads on the tip are obtained by superposition of the steady aerodynamic results for angle of attack and camber, and the unsteady results for the response to the sinusoidal gust. The near field disturbance pressures in the fluid surrounding the tip are obtained by assuming a dipole representation for the loading on the tip and calculating the pressures accordingly. The near field pressures are used to drive a reduced form of the Navier-Stokes equations which yield the tip vortex formation. The combined viscid-inviscid analysis is applied to determining the pressures and examining the vortex rollup in the vicinity of an unswept, uncambered wing moving steadily at a Mach number of 0.2 at an angle of attack of 0.1 rad. The viscous tip flow calculation shows features expected in the tip flow such as the qualitatively proper development of boundary layers on both the upper and lower airfoil surfaces. In addition, application of the viscous solution leads to the generation of a circular type flow pattern above the airfoil suction surface.

  1. Blade tip timing (BTT) uncertainties

    NASA Astrophysics Data System (ADS)

    Russhard, Pete

    2016-06-01

    Blade Tip Timing (BTT) is an alternative technique for characterising blade vibration in which non-contact timing probes (e.g. capacitance or optical probes), typically mounted on the engine casing (figure 1), and are used to measure the time at which a blade passes each probe. This time is compared with the time at which the blade would have passed the probe if it had been undergoing no vibration. For a number of years the aerospace industry has been sponsoring research into Blade Tip Timing technologies that have been developed as tools to obtain rotor blade tip deflections. These have been successful in demonstrating the potential of the technology, but rarely produced quantitative data, along with a demonstration of a traceable value for measurement uncertainty. BTT technologies have been developed under a cloak of secrecy by the gas turbine OEM's due to the competitive advantages it offered if it could be shown to work. BTT measurements are sensitive to many variables and there is a need to quantify the measurement uncertainty of the complete technology and to define a set of guidelines as to how BTT should be applied to different vehicles. The data shown in figure 2 was developed from US government sponsored program that bought together four different tip timing system and a gas turbine engine test. Comparisons showed that they were just capable of obtaining measurement within a +/-25% uncertainty band when compared to strain gauges even when using the same input data sets.

  2. Tip-over prevention through heuristic reactive behaviors for unmanned ground vehicles

    NASA Astrophysics Data System (ADS)

    Talke, Kurt; Kelley, Leah; Longhini, Patrick; Catron, Garret

    2014-06-01

    , previously experimentally validated, to predict the likelihood of robot tip-over and trigger prevention behaviors. A unique heuristic approach to tip-over avoidance was investigated, wherein a set of evasive maneuvers that an expert teleoperator might take are activated when the tip-over-likelihood estimate passes a critical threshold. This control approach was validated on an iRobot Packbot as well as on a Segway RMP 440. The heuristic laws demonstrated the advantage of alerting operators to a tip-over scenario and gave them more time to correct the situation, as well as the ability to automatically initiate recovery on the y". This research shows promise in preventing dangerous scenarios that could damage a robot and/or compromise its mission, thus saving lives. It further provides a good foundation for follow-on development involving the expansion and integration of the prevention-control algorithms, to include movable payloads, environment manipulation, 2D or 3D look-ahead laser sensing and mapping, and adaptive path planning.

  3. RETINAL DEEP CAPILLARY ISCHEMIA ASSOCIATED WITH AN OCCLUDED CONGENITAL RETINAL MACROVESSEL.

    PubMed

    Hasegawa, Taiji; Ogata, Nahoko

    2017-01-01

    To report the case of a patient with an occluded congenital retinal macrovessel accompanied by retinal deep capillary ischemia. A 38-year-old woman presented with a 2-day history of a paracentral scotoma of her right eye. Fundus photograph showed a dilated congenital retinal macrovessel with arteriovenous anastomosis, an intravascular white region indicating the thrombus at arteriovenous anastomotic region, and an area of retinal whitening temporal to the fovea. The spectral domain optical coherence tomography images through the area of retinal whitening showed a thickening and highly reflectivity at the level of the inner nuclear layer, which is likely due to the deep capillary ischemia. After 6 weeks, spectral domain optical coherence tomography images through the same area demonstrated a thinning and atrophy of only the inner nuclear layer, and the patient's paracentral scotoma persisted. Acute capillary hemodynamic changes caused deep capillary ischemia. The spectral domain optical coherence tomography showed a highly reflective lesion at the level of the inner nuclear layer in the acute phase.

  4. Analysis, design, fabrication and testing of an optical tip clearance sensor. [turbocompressor blade tips

    NASA Technical Reports Server (NTRS)

    Poppel, G. L.; Marple, D. T. F.; Kingsley, J. D.

    1981-01-01

    Analyses and the design, fabrication, and testing of an optical tip clearance sensor with intended application in aircraft propulsion control systems are reported. The design of a sensor test rig, evaluation of optical sensor components at elevated temperatures, sensor design principles, sensor test results at room temperature, and estimations of sensor accuracy at temperatures of an aircraft engine environment are discussed. Room temperature testing indicated possible measurement accuracies of less than 12.7 microns (0.5 mils). Ways to improve performance at engine operating temperatures are recommended. The potential of this tip clearance sensor is assessed.

  5. 21 CFR 880.6025 - Absorbent tipped applicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... stick. The device is used to apply medications to, or to take specimens from, a patient. (b...) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Miscellaneous Devices § 880.6025 Absorbent tipped applicator. (a) Identification. An absorbent tipped applicator is a...

  6. Reversible mechano-electrochemical writing of metallic nanostructures with the tip of an atomic force microscope.

    PubMed

    Obermair, Christian; Kress, Marina; Wagner, Andreas; Schimmel, Thomas

    2012-01-01

    We recently introduced a method that allows the controlled deposition of nanoscale metallic patterns at defined locations using the tip of an atomic force microscope (AFM) as a "mechano-electrochemical pen", locally activating a passivated substrate surface for site-selective electrochemical deposition. Here, we demonstrate the reversibility of this process and study the long-term stability of the resulting metallic structures. The remarkable stability for more than 1.5 years under ambient air without any observable changes can be attributed to self-passivation. After AFM-activated electrochemical deposition of copper nanostructures on a polycrystalline gold film and subsequent AFM imaging, the copper nanostructures could be dissolved by reversing the electrochemical potential. Subsequent AFM-tip-activated deposition of different copper nanostructures at the same location where the previous structures were deleted, shows that there is no observable memory effect, i.e., no effect of the previous writing process on the subsequent writing process. Thus, the four processes required for reversible information storage, "write", "read", "delete" and "re-write", were successfully demonstrated on the nanometer scale.

  7. Reversible mechano-electrochemical writing of metallic nanostructures with the tip of an atomic force microscope

    PubMed Central

    Kress, Marina; Wagner, Andreas; Schimmel, Thomas

    2012-01-01

    Summary We recently introduced a method that allows the controlled deposition of nanoscale metallic patterns at defined locations using the tip of an atomic force microscope (AFM) as a “mechano-electrochemical pen”, locally activating a passivated substrate surface for site-selective electrochemical deposition. Here, we demonstrate the reversibility of this process and study the long-term stability of the resulting metallic structures. The remarkable stability for more than 1.5 years under ambient air without any observable changes can be attributed to self-passivation. After AFM-activated electrochemical deposition of copper nanostructures on a polycrystalline gold film and subsequent AFM imaging, the copper nanostructures could be dissolved by reversing the electrochemical potential. Subsequent AFM-tip-activated deposition of different copper nanostructures at the same location where the previous structures were deleted, shows that there is no observable memory effect, i.e., no effect of the previous writing process on the subsequent writing process. Thus, the four processes required for reversible information storage, “write”, “read”, “delete” and “re-write”, were successfully demonstrated on the nanometer scale. PMID:23365795

  8. Sharp Tips on the Atomic Force Microscope

    NASA Technical Reports Server (NTRS)

    2008-01-01

    This image shows the eight sharp tips of the NASA's Phoenix Mars Lander's Atomic Force Microscope, or AFM. The AFM is part of Phoenix's Microscopy, Electrochemistry, and Conductivity Analyzer, or MECA.

    The microscope maps the shape of particles in three dimensions by scanning them with one of the tips at the end of a beam. For the AFM image taken, the tip at the end of the upper right beam was used. The tip pointing up in the enlarged image is the size of a smoke particle at its base, or 2 microns. This image was taken with a scanning electron microscope before Phoenix launched on August 4, 2007.

    The AFM was developed by a Swiss-led consortium in collaboration with Imperial College London.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  9. Some observations of tip-vortex cavitation

    NASA Astrophysics Data System (ADS)

    Arndt, R. E. A.; Arakeri, V. H.; Higuchi, H.

    1991-08-01

    Cavitation has been observed in the trailing vortex system of an elliptic platform hydrofoil. A complex dependence on Reynolds number and gas content is noted at inception. Some of the observations can be related to tension effects associated with the lack of sufficiently large-sized nuclei. Inception measurements are compared with estimates of pressure in the vortex obtained from LDV measurements of velocity within the vortex. It is concluded that a complete correlation is not possible without knowledge of the fluctuating levels of pressure in tip-vortex flows. When cavitation is fully developed, the observed tip-vortex trajectory flows. When cavitation is fully developed, the observed tip-vortex trajectory shows a surprising lack of dependence on any of the physical parameters varied, such as angle of attack, Reynolds number, cavitation number, and dissolved gas content.

  10. Recovery patterns, histological observations and genetic integrity in Malus shoot tips cryopreserved using droplet-vitrification and encapsulation-dehydration procedures.

    PubMed

    Li, Bai-Quan; Feng, Chao-Hong; Wang, Min-Rui; Hu, Ling-Yun; Volk, Gayle; Wang, Qiao-Chun

    2015-11-20

    A droplet-vitrification procedure is described for cryopreservation of Malus shoot tips. Survival patterns, recovery types, histological observations, and genetic integrity were compared for Malus shoot tips cryopreserved using this droplet-vitrification procedure and an encapsulation-dehydration procedure that was previously reported by us. In both procedures, three types of shoot tip recovery were observed following cryopreservation: callus formation without shoot regrowth, leaf formation without shoot regrowth, and shoot regrowth. Three categories of histological observations were also identified in cross-sections of shoot tips recovered after cryopreservation using the two cryogenic procedures. In category 1, almost all of the cells (94-95%) in the apical dome (AD) were damaged or killed and only some cells (30-32%) in the leaf primordia (LPs) survived. In category 2, only a few cells (18-20%) in the AD and some cells (30-31%) in the LPs survived. In category 3, majority of the cells (60-62%) in the AD and some cells (30-33%) in the LPs survived. These data suggest that shoot regrowth is correlated to the presence of a majority of surviving cells in the AD after liquid nitrogen exposure. No polymorphic bands were detected by inter-simple sequence repeats or by random amplified polymorphic DNA assessments, and ploidy levels analyzed by flow cytometry were unchanged when plants recovered after cryoexposure were compared to controls. The droplet-vitrification procedure appears to be robust since seven genotypes representing four Malus species and one hybrid recovered shoots following cryopreservation. Mean shoot regrowth levels of these seven genotypes were 48% in the droplet-vitrification method, which were lower than those (61%) in the encapsulation-dehydration procedure reported in our previous study, suggesting the latter may be preferred for routine cryobanking applications for Malus shoot tips. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. A tip-localized RhoGAP controls cell polarity by globally inhibiting Rho GTPase at the cell apex.

    PubMed

    Hwang, Jae-Ung; Vernoud, Vanessa; Szumlanski, Amy; Nielsen, Erik; Yang, Zhenbiao

    2008-12-23

    Highly elongated eukaryotic cells (e.g., neuronal axons, fungal hyphae, and pollen tubes) are generated through continuous apically restricted growth (tip growth), which universally requires tip-localized Rho GTPases. We used the oscillating pollen tube as a model system to determine the function and regulation of Rho GTPases in tip growth. Our previous work showed that the spatiotemporal dynamics of the apical cap of the activated Rho-like GTPase from Plant 1 (ROP1) are critical for tip growth in pollen tubes. However, the underlying mechanism for the generation and maintenance of this dynamic apical cap is poorly understood. A screen for mutations that enhance ROP1-overexpression-induced depolarization of pollen-tube growth identified REN1 (ROP1 enhancer 1) in Arabidopsis, whose null mutations turn elongated pollen tubes into bulbous cells. REN1 encodes a novel Rho GTPase-activating protein (RhoGAP) required for restricting the ROP1 activity to the pollen-tube tip. REN1 was localized to exocytic vesicles accumulated in the pollen-tube apex, as well as to the apical plasma membrane at the site of ROP1 activation. The apical localization of REN1 and its function in controlling growth polarity was compromised by disruption of ROP1-dependent F-actin and vesicular trafficking, which indicates that REN1 targeting and function is regulated by ROP1 downstream signaling. Our findings suggest that the REN1 RhoGAP controls a negative-feedback-based global inhibition of ROP1. This function provides a critical self-organizing mechanism, by which ROP signaling is spatially limited to the growth site and temporally oscillates during continuous tip growth. Similar spatiotemporal control of Rho GTPase signaling may also play an important role in cell-polarity control in other systems, including tip growth in fungi and cell movement in animals.

  12. 100 Consejos para los Padres (100 Tips for Parents).

    ERIC Educational Resources Information Center

    Department of Education, Washington, DC.

    Noting that involved parents can improve their children's chances of succeeding in school, this packet of Spanish-language cards offers 100 tips created to help parents become more involved in their child's education. Following a card of general tips on becoming involved, tips are offered in the following topic areas: keeping a child alcohol,…

  13. Direct observation of the actin filament by tip-scan atomic force microscopy

    PubMed Central

    Narita, Akihiro; Usukura, Eiji; Yagi, Akira; Tateyama, Kiyohiko; Akizuki, Shogo; Kikumoto, Mahito; Matsumoto, Tomoharu; Maéda, Yuichiro; Ito, Shuichi; Usukura, Jiro

    2016-01-01

    Actin filaments, the actin–myosin complex and the actin–tropomyosin complex were observed by a tip-scan atomic force microscope (AFM), which was recently developed by Olympus as the AFM part of a correlative microscope. This newly developed AFM uses cantilevers of similar size as stage-scan AFMs to improve substantially the spatial and temporal resolution. Such an approach has previously never been possible by a tip-scan system, in which a cantilever moves in the x, y and z directions. We evaluated the performance of this developed tip-scan AFM by observing the molecular structure of actin filaments and the actin–tropomyosin complex. In the image of the actin filament, the molecular interval of the actin subunits (∼5.5 nm) was clearly observed as stripes. From the shape of the stripes, the polarity of the actin filament was directly determined and the results were consistent with the polarity determined by myosin binding. In the image of the actin–tropomyosin complex, each tropomyosin molecule (∼2 nm in diameter) on the actin filament was directly observed without averaging images of different molecules. Each tropomyosin molecule on the actin filament has never been directly observed by AFM or electron microscopy. Thus, our developed tip-scan AFM offers significant potential in observing purified proteins and cellular structures at nanometer resolution. Current results represent an important step in the development of a new correlative microscope to observe nm-order structures at an acceptable frame rate (∼10 s/frame) by AFM at the position indicated by the fluorescent dye observed under a light microscope. PMID:27242058

  14. Unveiling Singlet Fission Mediating States in TIPS-pentacene and its Aza Derivatives.

    PubMed

    Herz, Julia; Buckup, Tiago; Paulus, Fabian; Engelhart, Jens U; Bunz, Uwe H F; Motzkus, Marcus

    2015-06-25

    Femtosecond pump-depletion-probe experiments were carried out in order to shed light on the ultrafast excited-state dynamics of triisopropylsilylethynyl (TIPS)-pentacene and two nitrogen-containing derivatives, namely, diaza-TIPS-pentacene and tetraaza-TIPS-pentacene. Measurements performed in the visible and near-infrared spectral range in combination with rate model simulations reveal that singlet fission proceeds via the extremely short-lived intermediate (1)TT state, which absorbs in the near-infrared spectral region only. The T1 → T3 transition probed in the visible region shows a rise time that comprises two components according to a consecutive reaction (S1 → (1)TT → T1). The incorporation of nitrogen atoms into the acene structure leads to shorter dynamics, but the overall triplet formation follows the same kinetic model. This is of particular importance, since experiments on tetraaza-TIPS-pentacene allow for investigation of the triplet state in the visible range without an overlapping singlet contribution. In addition, the pump-depletion-probe experiments show that the triplet absorption in the visible (T1 → T3) and near-infrared (T1 → T2) regions occurs from the same initial state, which was questioned in previous studies. Furthermore, an additional ultrafast transfer between the excited triplet states (T3 → T2) is identified, which is also in agreement with the rate model simulation. By applying depletion pulses, which are resonant with higher vibrational levels, we gain insight into internal vibrational energy redistribution processes within the triplet manifold. This additional information is of great relevance regarding the study of loss channels within these materials.

  15. The tip-link antigen, a protein associated with the transduction complex of sensory hair cells, is protocadherin-15.

    PubMed

    Ahmed, Zubair M; Goodyear, Richard; Riazuddin, Saima; Lagziel, Ayala; Legan, P Kevin; Behra, Martine; Burgess, Shawn M; Lilley, Kathryn S; Wilcox, Edward R; Riazuddin, Sheikh; Griffith, Andrew J; Frolenkov, Gregory I; Belyantseva, Inna A; Richardson, Guy P; Friedman, Thomas B

    2006-06-28

    Sound and acceleration are detected by hair bundles, mechanosensory structures located at the apical pole of hair cells in the inner ear. The different elements of the hair bundle, the stereocilia and a kinocilium, are interconnected by a variety of link types. One of these links, the tip link, connects the top of a shorter stereocilium with the lateral membrane of an adjacent taller stereocilium and may gate the mechanotransducer channel of the hair cell. Mass spectrometric and Western blot analyses identify the tip-link antigen, a hitherto unidentified antigen specifically associated with the tip and kinocilial links of sensory hair bundles in the inner ear and the ciliary calyx of photoreceptors in the eye, as an avian ortholog of human protocadherin-15, a product of the gene for the deaf/blindness Usher syndrome type 1F/DFNB23 locus. Multiple protocadherin-15 transcripts are shown to be expressed in the mouse inner ear, and these define four major isoform classes, two with entirely novel, previously unidentified cytoplasmic domains. Antibodies to the three cytoplasmic domain-containing isoform classes reveal that each has a different spatiotemporal expression pattern in the developing and mature inner ear. Two isoforms are distributed in a manner compatible for association with the tip-link complex. An isoform located at the tips of stereocilia is sensitive to calcium chelation and proteolysis with subtilisin and reappears at the tips of stereocilia as transduction recovers after the removal of calcium chelators. Protocadherin-15 is therefore associated with the tip-link complex and may be an integral component of this structure and/or required for its formation.

  16. Novel cylindrical illuminator tip for ultraviolet light delivery

    NASA Astrophysics Data System (ADS)

    Shangguan, HanQun; Haw, Thomas E.; Gregory, Kenton W.; Casperson, Lee W.

    1993-06-01

    The design, processing, and sequential testing of a novel cylindrical diffusing optical fiber tip for ultraviolet light delivery is described. This device has been shown to uniformly (+/- 15%) illuminate angioplasty balloons, 20 mm in length, that are used in an experimental photochemotherapeutic treatment of swine intimal hyperplasia. Our experiments show that uniform diffusing tips of < 400 micron diameter can be reliably constructed for this and other interstitial applications. Modeling results indicate that this design is scalable to smaller diameters. The diffusing tips are made by stripping the protective buffer and etching away the cladding over a length of 20 mm from the fiber tip and replacing it with a thin layer of optical epoxy mixed with Al2O3 powder. To improve the uniformity and ease of fabrication, we have evaluated a new device configuration where the tip is etched into a modified conical shape, and the distal end face is polished and then coated with an optically opaque epoxy. This is shown to uniformly scatter approximately 70% of the light launched into the fiber without forward transmission.

  17. Study of mechanical behavior of AFM silicon tips under mechanical load

    NASA Astrophysics Data System (ADS)

    Kopycinska-Mueller, M.; Gluch, J.; Köhler, B.

    2016-11-01

    In this paper we address critical issues concerning calibration of AFM based methods used for nanoscale mechanical characterization of materials. It has been shown that calibration approaches based on macroscopic models for contact mechanics may yield excellent results in terms of the indentation modulus of the sample, but fail to provide a comprehensive and actual information concerning the tip-sample contact radius or the mechanical properties of the tip. Explanations for the severely reduced indentation modulus of the tip included the inadequacies of the models used for calculations of the tip-sample contact stiffness, discrepancies in the actual and ideal shape of the tip, presence of the amorphous silicon phase within the silicon tip, as well as negligence of the actual size of the stress field created in the tip during elastic interactions. To clarify these issues, we investigated the influence of the mechanical load applied to four AFM silicon tips on their crystalline state by exposing them to systematically increasing loads, evaluating the character of the tip-sample interactions via the load-unload stiffness curves, and assessing the state of the tips from HR-TEM images. The results presented in this paper were obtained in a series of relatively simple and basic atomic force acoustic microscopy (AFAM) experiments. The novel combination of TEM imaging of the AFM tips with the analysis of the load-unload stiffness curves gave us a detailed insight into their mechanical behavior under load conditions. We were able to identify the limits for the elastic interactions, as well as the hallmarks for phase transformation and dislocation formation and movement. The comparison of the physical dimensions of the AFM tips, geometry parameters determined from the values of the contact stiffness, and the information on the crystalline state of the tips allowed us a better understanding of the nanoscale contact.

  18. Cooling circuit for a gas turbine bucket and tip shroud

    DOEpatents

    Willett, Fred Thomas; Itzel, Gary Michael; Stathopoulos, Dimitrios; Plemmons, Larry Wayne; Plemmons, Helen M.; Lewis, Doyle C.

    2002-01-01

    An open cooling circuit for a gas turbine bucket wherein the bucket has an airfoil portion, and a tip shroud, the cooling circuit including a plurality of radial cooling holes extending through the airfoil portion and communicating with an enlarged internal area within the tip shroud before exiting the tip shroud such that a cooling medium used to cool the airfoil portion is subsequently used to cool the tip shroud.

  19. Turbine blade tip clearance measurements using skewed dual optical beams of tip timing

    NASA Astrophysics Data System (ADS)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2011-12-01

    Optimization and active control of the clearance between turbine blades and case of the engine is identified, especially in aerospace community, as a key technology to increase engine efficiency, reduce fuel consumption and emissions and increase service life .However, the tip clearance varies during different operating conditions. Thus a reliable non-contact and online detection system is essential and ultimately used to close the tip clearance control loop. This paper described a fiber optical clearance measuring system applying skewed dual optical beams to detect the traverse time of passing blades. Two beams were specially designed with an outward angle of 18 degree and the beam spot diameters are less than 100μm within 0-4mm working range to achieve high signal-to-noise and high sensitivity. It could be theoretically analyzed that the measuring accuracy is not compromised by degradation of signal intensity caused by any number of environmental conditions such as light source instability, contamination and blade tip imperfection. Experimental tests were undertaken to achieve a high resolution of 10µm in the rotational speed range 2000-18000RPM and a measurement accuracy of 15μm, indicating that the system is capable of providing accurate and reliable data for active clearance control (ACC).

  20. New Technique for Fabrication of Scanning Single-Electron Transistor Microscopy Tips

    NASA Astrophysics Data System (ADS)

    Goodwin, Eric; Tessmer, Stuart

    Fabrication of glass tips for Scanning Single-Electron Transistor Microscopy (SSETM) can be expensive, time consuming, and inconsistent. Various techniques have been tried, with varying levels of success in regards to cost and reproducibility. The main requirement for SSETM tips is to have a sharp tip ending in a micron-scale flat face to allow for deposition of a quantum dot. Drawing inspiration from methods used to create tips from optical fibers for Near-Field Scanning Optical Microscopes, our group has come up with a quick and cost effective process for creating SSETM tips. By utilizing hydrofluoric acid to etch the tips and oleic acid to guide the etch profile, optical fiber tips with appropriate shaping can be rapidly prepared. Once etched, electric leads are thermally evaporated onto each side of the tip, while an aluminum quantum dot is evaporated onto the face. Preliminary results using various metals, oxide layers, and lead thicknesses have proven promising.

  1. Voice Quality After a Semi-Occluded Vocal Tract Exercise With a Ventilation Mask in Contemporary Commercial Singers: Acoustic Analysis and Self-Assessments.

    PubMed

    Fantini, Marco; Succo, Giovanni; Crosetti, Erika; Borragán Torre, Alfonso; Demo, Roberto; Fussi, Franco

    2017-05-01

    The current study aimed at investigating the immediate effects of a semi-occluded vocal tract exercise with a ventilation mask in a group of contemporary commercial singers. A randomized controlled study was carried out. Thirty professional or semi-professional singers with no voice complaints were randomly divided into two groups on recruitment: an experimental group and a control group. The same warm-up exercise was performed by the experimental group with an occluded ventilation mask placed over the nose and the mouth and by the control group without the ventilation mask. Voice was recorded before and after the exercise. Acoustic and self-assessment analysis were accomplished. The acoustic parameters of the voice samples recorded before and after training were compared, as well as the parameters' variations between the experimental and the control group. Self-assessment results of the experimental and the control group were compared too. Significant changes after the warm-up exercise included jitter, shimmer, and singing power ratio (SPR) in the experimental group. No significant changes were recorded in the control group. Significant differences between the experimental and the control group were found for ΔShimmer and ΔSPR. Self-assessment analysis confirmed a significantly higher phonatory comfort and voice quality perception for the experimental group. The results of the present study support the immediate advantageous effects on singing voice of a semi-occluded vocal tract exercise with a ventilation mask in terms of acoustic quality, phonatory comfort, and voice quality perception in contemporary commercial singers. Long-term effects still remain to be studied. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Jagged gives endothelial tip cells an edge.

    PubMed

    Suchting, Steven; Eichmann, Anne

    2009-06-12

    Sprouting blood vessels have tip cells that lead and stalk cells that follow. Benedito et al. (2009) now show that competition between endothelial cells for the tip position is regulated by glycosylation of Notch receptors and by the opposing actions of the Notch ligands Jagged1 and Delta-like 4.

  3. Crutches and children - proper fit and safety tips

    MedlinePlus

    ... 000640.htm Crutches and children - proper fit and safety tips To use the sharing features on this ... the crutch, then extended when taking a step. Safety Tips Teach your child to: Always keep crutches ...

  4. Tip cells: master regulators of tubulogenesis?

    PubMed

    Weavers, Helen; Skaer, Helen

    2014-07-01

    The normal development of an organ depends on the coordinated regulation of multiple cell activities. Focusing on tubulogenesis, we review the role of specialised cells or groups of cells that are selected from within tissue primordia and differentiate at the outgrowing tips or leading edge of developing tubules. Tip or leading cells develop distinctive patterns of gene expression that enable them to act both as sensors and transmitters of intercellular signalling. This enables them to explore the environment, respond to both tissue intrinsic signals and extrinsic cues from surrounding tissues and to regulate the behaviour of their neighbours, including the setting of cell fate, patterning cell division, inducing polarity and promoting cell movement and cell rearrangements by neighbour exchange. Tip cells are also able to transmit mechanical tension to promote tissue remodelling and, by interacting with the extracellular matrix, they can dictate migratory pathways and organ shape. Where separate tubular structures fuse to form networks, as in the airways of insects or the vascular system of vertebrates, specialised fusion tip cells act to interconnect disparate elements of the developing network. Finally, we consider their importance in the maturation of mature physiological function and in the development of disease. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Optimisation of readout performance of phase-change probe memory in terms of capping layer and probe tip

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Wright, C. David; Aziz, Mustafa. M.; Yang, Ci Hui; Yang, Guo Wei

    2014-11-01

    The capping layer and the probe tip that serve as the protective layer and the recording tool, respectively, for phase-change probe memory play an important role on the writing performance of phase-change probe memory, thus receiving considerable attention. On the other hand, their influence on the readout performance of phasechange probe memory has rarely been reported before. A three-dimensional parametric study based on the Laplace equation was therefore conducted to investigate the effect of the capping layer and the probe tip on the resulting reading contrast for the two cases of reading a crystalline bit from an amorphous matrix and reading an amorphous bit from a crystalline matrix. The results indicated that a capping layer with a thickness of 2 nm and an electrical conductivity of 50 Ω-1m-1 is able to provide an appropriate reading contrast for both the cases, while satisfying the previous writing requirement, particularly with the assistance of a platinum silicide probe tip.

  6. Tips for Breastfeeding Moms

    MedlinePlus

    United States Department of Agriculture Tips for Breastfeeding Moms Making healthy food choices along with regular physical activity will keep you healthy while you breastfeed. Find Your Healthy Eating Style Choose ...

  7. Development and testing of tip devices for horizontal axis wind turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gyatt, G.W.; Lissaman, P.B.S.

    1985-05-01

    A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. Objective was to improve performance by the reduction of tip losses. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbines. The types were a change in tip planform, and a single-element and double-element nonplannar tip extension (winglets). Approximately 270 h of performance data were collected over a three-month period. The sampling interval was 2.4 s; thus over 400,000 raw data points were logged.more » Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted. The computer model used does not have adequate lifting surface resolution or accuracy to design these small winglet extensions.« less

  8. Transcatheter closure of a large patent ductus arteriosus in a young child using the Amplatzer duct occluder.

    PubMed

    Jan, S-L; Hwang, B; Fu, Y-C; Chi, C-S

    2005-01-01

    The Amplatzer duct occluder (ADO) provides a safe and effective therapy for patients with moderate- to large-sized patent ductus arteriosus (PDA), but there have been few reports of transcatheter closure of very large PDAs in young children and infants. We report a successful transcatheter closure of a very large PDA, 10.5 mm in diameter at the narrowest point, with a 14/12-mm ADO. To our knowledge, this is the largest PDA ever closed by an interventional method in such a young child.

  9. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    NASA Technical Reports Server (NTRS)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  10. Multipurpose fiber-optic sensor with sloped tip

    NASA Astrophysics Data System (ADS)

    Melnik, Ivan S.; Krivokhizha, A. M.; Ptashnik, O. V.

    1991-08-01

    Fiber-optic sensors C FOS) are wi. del y used for rioncontact measurements due to their simplicity, small size, insensitivity to I nfl uence of el ectromagneti C fiel ds , hi gh metrol ogi cal characteristics, etc. The operation principle of FOS with intensity modul ati on techni que I s based on the photodetector regi strati on of 1ight , reflected from the control 1 ed surface E I ) . The i ntensi ty of detected 1 1 ght depends on th FOS' s di stance from the control 1 ed surface, its form and inclination to sensor's axis, FOS shift speed, etc. So they can be consider multipurpose. We are devel opi ng FOS wi th i ntensi ty modul ati on techni que wi th traight tips as well as with sloped tips. In FOS with sloped tips the light ring spot is appearing on the controlled surface due to the effect of symmetry. We use thi s phenomena to empl oy refl ected 1 i ght more efficiently and to increase the FOS characteristics. Tak i ng I nto account the fact that pr obl ems of cal cul aWl on of fibers with sloped tip were not analyzed in details earlier-, in particular, only the case of light distribution of parallel beams runni ng was consi dered E 2) we wi I 1 conduct a consi stent cal cul ati on of bounds of i rradi ance fi ci d , created by a fi ber wi th sl oped tip, esti mate I i ght di stri buti on I n a 1 1 ght spot , and determi. ne characteristics of the FOS with sloped tip.

  11. Development and testing of tip devices for horizontal axis wind turbines

    NASA Technical Reports Server (NTRS)

    Gyatt, G. W.; Lissaman, P. B. S.

    1985-01-01

    A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. The objective was to improve performance by the reduction of tip losses. While power output can always be increased by a simple radial tip extension, such a modification also results in an increased gale load both because of the extra projected area and longer moment arm. Tip devices have the potential to increase power output without such a structural penalty. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbine. The types were a change in tip planform, and a single-element and double-element nonplanar tip extension (winglets). A complete data acquisition system was developed which recorded three wind speed components, ambient pressure, temperature, and turbine output. The system operated unattended and could perform real-time processing of the data, displaying the measured power curve as data accumulated in either a bin sort mode or polynomial curve fit. Approximately 270 hr of perormance data were collected over a three-month period. The sampling interval was 2.4 sec; thrus over 400,000 raw data points were logged. Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. Changes in orientation and angle-of-attack of the winglets were not made. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted.

  12. 7 CFR 29.3154 - Tips (T Group).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... stalk. (See Rule 12.) Grades Grade names and specifications T3F Good Tan Tips. Medium body, mature to..., mature, firm, wavy dull finish, weak color intensity, narrow, under 16″ in length, 80 percent uniform, and 20 percent injury tolerance. T5F Low Tan Tips. Medium body, mature, firm, wrinkly, dingy finish...

  13. 7 CFR 29.3154 - Tips (T Group).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... stalk. (See Rule 12.) Grades Grade names and specifications T3F Good Tan Tips. Medium body, mature to..., mature, firm, wavy dull finish, weak color intensity, narrow, under 16″ in length, 80 percent uniform, and 20 percent injury tolerance. T5F Low Tan Tips. Medium body, mature, firm, wrinkly, dingy finish...

  14. 7 CFR 29.3154 - Tips (T Group).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... stalk. (See Rule 12.) Grades Grade names and specifications T3F Good Tan Tips. Medium body, mature to..., mature, firm, wavy dull finish, weak color intensity, narrow, under 16″ in length, 80 percent uniform, and 20 percent injury tolerance. T5F Low Tan Tips. Medium body, mature, firm, wrinkly, dingy finish...

  15. Back-to-School Health Tips: Exercise and Sleep

    MedlinePlus

    ... up the same times each day. Keep room temperature on the cool side. A TV or computer in the bedroom can be a distraction. Read More "Back-to-School" Articles Health Tips: Immunizations / Health Tips: Exercise and ...

  16. Modeling the Interaction between AFM Tips and Pinned Surface Nanobubbles.

    PubMed

    Guo, Zhenjiang; Liu, Yawei; Xiao, Qianxiang; Schönherr, Holger; Zhang, Xianren

    2016-01-26

    Although the morphology of surface nanobubbles has been studied widely with different AFM modes, AFM images may not reflect the real shapes of the nanobubbles due to AFM tip-nanobubble interactions. In addition, the interplay between surface nanobubble deformation and induced capillary force has not been well understood in this context. In our work we used constraint lattice density functional theory to investigate the interaction between AFM tips and pinned surface nanobubbles systematically, especially concentrating on the effects of tip hydrophilicity and shape. For a hydrophilic tip contacting a nanobubble, its hydrophilic nature facilitates its departure from the bubble surface, displaying a weak and intermediate-range attraction. However, when the tip squeezes the nanobubble during the approach process, the nanobubble shows an elastic effect that prevents the tip from penetrating the bubble, leading to a strong nanobubble deformation and repulsive interactions. On the contrary, a hydrophobic tip can easily pierce the vapor-liquid interface of the nanobubble during the approach process, leading to the disappearance of the repulsive force. In the retraction process, however, the adhesion between the tip and the nanobubble leads to a much stronger lengthening effect on nanobubble deformation and a strong long-range attractive force. The trends of force evolution from our simulations agree qualitatively well with recent experimental AFM observations. This favorable agreement demonstrates that our model catches the main intergradient of tip-nanobubble interactions for pinned surface nanobubbles and may therefore provide important insight into how to design minimally invasive AFM experiments.

  17. Hand interception of occluded motion in humans: a test of model-based vs. on-line control

    PubMed Central

    Zago, Myrka; Lacquaniti, Francesco

    2015-01-01

    Two control schemes have been hypothesized for the manual interception of fast visual targets. In the model-free on-line control, extrapolation of target motion is based on continuous visual information, without resorting to physical models. In the model-based control, instead, a prior model of target motion predicts the future spatiotemporal trajectory. To distinguish between the two hypotheses in the case of projectile motion, we asked participants to hit a ball that rolled down an incline at 0.2 g and then fell in air at 1 g along a parabola. By varying starting position, ball velocity and trajectory differed between trials. Motion on the incline was always visible, whereas parabolic motion was either visible or occluded. We found that participants were equally successful at hitting the falling ball in both visible and occluded conditions. Moreover, in different trials the intersection points were distributed along the parabolic trajectories of the ball, indicating that subjects were able to extrapolate an extended segment of the target trajectory. Remarkably, this trend was observed even at the very first repetition of movements. These results are consistent with the hypothesis of model-based control, but not with on-line control. Indeed, ball path and speed during the occlusion could not be extrapolated solely from the kinematic information obtained during the preceding visible phase. The only way to extrapolate ball motion correctly during the occlusion was to assume that the ball would fall under gravity and air drag when hidden from view. Such an assumption had to be derived from prior experience. PMID:26133803

  18. High dose urokinase for restoration of patency of occluded permanent central venous catheters in hemodialysis patients.

    PubMed

    Shavit, L; Lifschitz, M; Plaksin, J; Grenader, T; Slotki, I

    2010-10-01

    Catheter thrombosis is common and results in inadequate dialysis treatment and, frequently, in catheter loss. Since dialysis treatment runs on a strict schedule, occluded catheters need to be restored in a timely and cost effective manner. We present a new shortened protocol of urokinase infusion that allows hemodialysis to be performed within 90 minutes. To chronic hemodialysis patients, who developed complete catheter occlusion, urokinase was infused simultaneously through both lumens of the catheter (125,000 units to each lumen) over 90 minutes. Technical success was defined as restoring blood pump speed to at least 250 ml/min. We determined the average time from catheter placement to first clot event (primary patency PP), recurrent clot event after urokinase treatment (secondary patency SP), catheter salvage rate and cause for removal. 37 catheters developed total thrombosis and urokinase was used to restore patency one or more times (total 47 treatments). Catheter salvage rate was 97 %. The average time of PP was 152 ± 56 days (7 - 784 days). Nine patients (30%) developed recurrent occlusion and the average time of SP was 64 ± 34 days (2 - 364 days). One catheter was removed because of dysfunction due to thrombosis. Other catheters were removed due to infection, fistula maturation or fell out spontaneously. Hemodialysis was performed immediately after treatment with blood speed of 250 ml/min in all patients. Our protocol is highly effective, short, and allows to restore patency of totally occluded central venous catheters with minimal disruption of the dialysis session.

  19. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE.more » The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)« less

  20. Fabrication of silver tips for scanning tunneling microscope induced luminescence.

    PubMed

    Zhang, C; Gao, B; Chen, L G; Meng, Q S; Yang, H; Zhang, R; Tao, X; Gao, H Y; Liao, Y; Dong, Z C

    2011-08-01

    We describe a reliable fabrication procedure of silver tips for scanning tunneling microscope (STM) induced luminescence experiments. The tip was first etched electrochemically to yield a sharp cone shape using selected electrolyte solutions and then sputter cleaned in ultrahigh vacuum to remove surface oxidation. The tip status, in particular the tip induced plasmon mode and its emission intensity, can be further tuned through field emission and voltage pulse. The quality of silver tips thus fabricated not only offers atomically resolved STM imaging, but more importantly, also allows us to perform challenging "color" photon mapping with emission spectra taken at each pixel simultaneously during the STM scan under relatively small tunnel currents and relatively short exposure time.

  1. Graded-index fiber tip optical tweezers: numerical simulation and trapping experiment.

    PubMed

    Gong, Yuan; Ye, Ai-Yan; Wu, Yu; Rao, Yun-Jiang; Yao, Yao; Xiao, Song

    2013-07-01

    Optical fiber tweezers based on a graded-index multimode fiber (GIMMF) tip is proposed. Light propagation characteristics and gradient force distribution near the GIMMF tip are numerically investigated, which are further compared with that of optical fiber tips based on conventional single mode fibers. The simulated results indicated that by selecting optimal GIMMF length, the gradient force of the GIMMF tip tweezers is about 4 times higher than that of the SMF tip tweezers with a same shape. To prove the feasibility of such a new concept, optical trapping of yeast cells with a diameter of ~5 μm using the chemically-etched GIMMF tip is experimentally demonstrated and the trapping force is also calculated.

  2. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Preprocedural Evaluation and Imaging

    PubMed Central

    Al-Osaimi, Abdullah M. S.; Sabri, Saher S.; Caldwell, Stephen H.

    2011-01-01

    Patients undergoing balloon retrograde transvenous obliteration (BRTO) are mostly decompensated cirrhotic with either bleeding gastric varices (GV) or hepatic encephalopathy. It is crucial that clinicians are up-to-date with the assessments needed prior to BRTO to anticipate and prevent complications, and to deliver critical quality care. These patients will require preprocedural assessments and management, including endoscopic, clinical, laboratory, and imaging evaluation. Endoscopic evaluation is mandatory prior to BRTO, and it is highly recommended that it be performed at the same institution where BRTO will be performed. It is essential that clinicians are aware of the potential benefits and complications that may result from BRTO. These complications should be anticipated and prevented when possible. For GV bleeders, there should be consideration of a transvenous intrahepatic portosystemic shunt (TIPS) during or before BRTO in patients with refractory ascites or pleural effusion, as well as endoscopic banding or a TIPS in patients with high-risk esophageal varices. Patients undergoing BRTO are usually complicated and require a team approach. In this article, the authors address these assessment and preparatory management and planning procedures prior to the BRTO procedure as well as expected outcomes and potential complications. PMID:22942546

  3. Static biofilm removal around ultrasonic tips in vitro.

    PubMed

    Thurnheer, Thomas; Rohrer, Elodie; Belibasakis, Georgios N; Attin, Thomas; Schmidlin, Patrick R

    2014-09-01

    This study aims to investigate the biofilm removal capacity of two ultrasonic tips under standardized conditions using a multi-species biofilm model. Six-species biofilms were grown on hydroxyapatite discs for 64.5 h and were treated for 15 s with a standardized load of 40 g with a piezoelectric or magnetostrictive device. Tips were applied either with the tip end or with the side facing downwards. Detached bacteria were determined in the supernatant and colony-forming units (CFUs) counted after 72 h of incubation. Untreated specimens served as controls. Moreover, the biofilms remaining on the hydroxyapatite surface after treatment were stained using the Live/Dead stain, and the pattern of their detachment was assessed by confocal laser scanning microscopy (CLSM). As compared to the untreated control, it was found that only a side application of the magnetostrictive device was able to remove efficiently the biofilm. In contrast, its tip application as well as both applications of the piezoelectric device removed significantly less bacteria from the biofilm structure. These findings were corroborated by CLSM observation. Both ultrasonic tips under investigations led to bacterial detachment, but the action mode as well as the tip configuration and adaptation appeared to be influenced by the biofilm removal effectiveness. Biofilm removal remains a main goal of ultrasonic debridement. This should be reflected in respective laboratory investigations. The presented combination of methods applied on a multi-species biofilm model in vitro allows the evaluation of the effectiveness of different ultrasonic scaler applications.

  4. Numerical simulation of tip vortices of wings in subsonic and transonic flows

    NASA Technical Reports Server (NTRS)

    Srinivasan, G. R.; Mccroskey, W. J.; Baeder, J. D.; Edwards, T. A.

    1986-01-01

    A multi block zonal algorithm which solves the thin-layer Navier-Stokes and the Euler equations is used to numerically simulate the formation and roll-up of the tip vortex in both subsonic and transonic flows. Four test cases which used small and large aspect ratio wings have been considered to examine the influence of the tip-cap shape, the tip planform and the free-stream Mach number. It appears that both the tip-planform and the tip-cap shape have some influence on the formation of the tip vortex, but its subsequent roll-up seems to be more influenced by the tip-planform shape. In general, a good definition of the formation and the roll-up of the tip vortex has been observed for all the cases considered here. Comparions of the numerical results with the limited, available experimental data show good agreement with both the surface pressures and the tip-vortex strength.

  5. A Blade Tip Timing Method Based on a Microwave Sensor

    PubMed Central

    Zhang, Jilong; Duan, Fajie; Niu, Guangyue; Jiang, Jiajia; Li, Jie

    2017-01-01

    Blade tip timing is an effective method for blade vibration measurements in turbomachinery. This method is increasing in popularity because it is non-intrusive and has several advantages over the conventional strain gauge method. Different kinds of sensors have been developed for blade tip timing, including optical, eddy current and capacitance sensors. However, these sensors are unsuitable in environments with contaminants or high temperatures. Microwave sensors offer a promising potential solution to overcome these limitations. In this article, a microwave sensor-based blade tip timing measurement system is proposed. A patch antenna probe is used to transmit and receive the microwave signals. The signal model and process method is analyzed. Zero intermediate frequency structure is employed to maintain timing accuracy and dynamic performance, and the received signal can also be used to measure tip clearance. The timing method uses the rising and falling edges of the signal and an auto-gain control circuit to reduce the effect of tip clearance change. To validate the accuracy of the system, it is compared experimentally with a fiber optic tip timing system. The results show that the microwave tip timing system achieves good accuracy. PMID:28492469

  6. A Blade Tip Timing Method Based on a Microwave Sensor.

    PubMed

    Zhang, Jilong; Duan, Fajie; Niu, Guangyue; Jiang, Jiajia; Li, Jie

    2017-05-11

    Blade tip timing is an effective method for blade vibration measurements in turbomachinery. This method is increasing in popularity because it is non-intrusive and has several advantages over the conventional strain gauge method. Different kinds of sensors have been developed for blade tip timing, including optical, eddy current and capacitance sensors. However, these sensors are unsuitable in environments with contaminants or high temperatures. Microwave sensors offer a promising potential solution to overcome these limitations. In this article, a microwave sensor-based blade tip timing measurement system is proposed. A patch antenna probe is used to transmit and receive the microwave signals. The signal model and process method is analyzed. Zero intermediate frequency structure is employed to maintain timing accuracy and dynamic performance, and the received signal can also be used to measure tip clearance. The timing method uses the rising and falling edges of the signal and an auto-gain control circuit to reduce the effect of tip clearance change. To validate the accuracy of the system, it is compared experimentally with a fiber optic tip timing system. The results show that the microwave tip timing system achieves good accuracy.

  7. Propeller Tip Flutter

    NASA Technical Reports Server (NTRS)

    Liebers, Fritz

    1932-01-01

    The present report is limited to a case of tip flutter recognized by experience as being important. It is the case where outside interferences force vibrations upon the propeller. Such interferences may be set up by the engine, or they may be the result of an unsymmetrical field of flow.

  8. Tips for labor coaches

    MedlinePlus

    ... some tips for getting prepared. Before the big day Arrives Labor coaches should go to childbirth classes ... get through her labor and delivery. When the day Arrives You might be at the hospital for ...

  9. Travel Tips Help IBS Sufferers Enjoy Their Vacations

    MedlinePlus

    ... can feel more in control when traveling." IFFGD's travel tips include: Allow enough time in the morning to get to the airport ... Heartache 2004-0929 Norton Honored 2004-0525 IBS Travel Tips ... Real World 2001-1119 Heartburn or Heart Attack Commentary ...

  10. Arrhythmias after transcatheter closure of perimembranous ventricular septal defects with a modified double-disk occluder: early and long-term results.

    PubMed

    Li, Pan; Zhao, Xian-xian; Zheng, Xing; Qin, Yong-wen

    2012-07-01

    With the development of interventional techniques and devices, transcatheter closure of perimembranous ventricular septal defect has been widely performed. However, there has been a lack of long-term follow-up results about postoperative ECG changes of PmVSD patients. We report our experience of early and late arrhythmias after transcatheter closure of PmVSD with a modified double-disk occluder (MDVO). We performed a retrospective review of 79 patients (47 males, 32 females) between September 2002 and May 2007 who underwent transcatheter closure of perimembranous ventricular septal defect. Symmetric and asymmetric PmVSD occluders were used. The diameter of the evaluated defects ranged from 3 to 12 mm, as measured by TTE and 3 to 15 mm by left ventriculography. Most cases of PmVSD were treated successfully with a single procedure, resulting in a successful closure rate of 97% (77/79 patients). There was no death in any of the patients. After the operation, 79 patients were followed-up for a range of 10-76 months (35.3 ± 17.4 months). In this series, 11 cases of incomplete right bundle branch block and five cases of complete right bundle branch block occurred during the early period after operation. During long-term follow-up, these issues declined in prevalence to five and four cases, respectively. Moreover, reversible third-degree AVB occurred during closure or after the procedure, and two of the three patients with reversible AVB received a temporary heart pacemaker implantation. These patients recovered 1 h, 6 days, and 9 days later, respectively. During 10-76 months of follow-up, no complications occurred in any of the patients, including residual shunt, severe aortic valve, or tricuspid valve regurgitation. Device closure of perimembranous ventricular septal defects with a modified double-disk occluder (MDVO) resulted in excellent closure rates and acceptably low arrhythmia rates.

  11. A comparison of the in vivo neoendothelialization and wound healing processes of three atrial septal defect occluders used during childhood in a nonrandomized prospective trial

    PubMed Central

    Şahin, Derya Aydın; Başpınar, Osman; Sülü, Ayşe; Karslıgil, Tekin; Kul, Seval

    2017-01-01

    Objective: We prospectively investigated the neoendothelialization of transcatheter secundum atrial septal defect (ASD) closure in children receiving one of three different occluders. Methods: Transcatheter ASD closure was performed for 44 children. The patients were divided into three groups: group I: Amplatzer, group II: Lifetech CeraFlex, and group III: Occlutech Figulla Flex II septal occluder. The data were prospectively analyzed. Markers of the three phases of wound healing were studied in all patients before and on the 1st and 10th days and 1st month post intervention. Results: The mean age of children was 7.08±3.51 years, and the mean weight was 26.07±15.07 kg. The mean ASD diameter was 12.65±3.50 mm. Groups I, II, and III comprised 34.1%, 31.8%, and 34.1% patients, respectively. No significant differences were observed between the groups regarding patient number, age, defect size, device diameter, or total septum/device ratio (p>0.05). Inflammatory and proliferative phase marker levels increased following the procedure (p<0.05). However, scar formation markers did not change after 1 month. No significant differences in neoendothelializaton were observed among the different occluders (p>0.05). Conclusion: All three devices were composed of nitinol with different surface coating techniques. Although the different manufacturing features were claimed to facilitate of neoendothelialization, no differences were observed among the three devices 1 month following the procedure. PMID:28761023

  12. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    NASA Astrophysics Data System (ADS)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  13. Complications Following Balloon-Occluded Arterial Infusion Chemotherapy for Pelvic Malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugimoto, Koji; Hirota, Shozo; Imanaka, Kazufumi

    Purpose: To evaluate the incidence and causes of complications associated with balloon-occluded arterial infusion chemotherapy (BOAI) for pelvic malignancies. Methods: In 34 courses of BOAI in 22 patients with pelvic malignancies, we analyzed the incidence of complications as well as the effect of the dose of the anticancer drugs, the infusion site, and the number of BOAI administrations on these complications. Complications were divided into two categories: cystitis-like symptoms and neurological complications such as pain, numbness, and paresthesia of the lower extremities and the hip. Results: Eleven patients (50%) suffered from complications, seven (31.8%) from neurological complications and four (18.2%)more » from cystitis-like symptoms. The complications appeared in 14 courses (42.4%) of BOAI, neurological complications in 10 (30.3%) and cystitis-like symptoms in four (12.1%). A high dose of anti-cancer drugs and infusion from the anterior division tended to induce neurological complications more frequently; however, the cystitis-like symptoms were not related to any factors. Conclusion: Our results indicate that a smaller dose of anti-cancer drugs should be infused from the bilateral internal iliac arteries for safer pelvic BOAI.« less

  14. The Case for Using Blunt-Tipped Lightning Rods as Strike Receptors.

    NASA Astrophysics Data System (ADS)

    Moore, C. B.; Aulich, G. D.; Rison, William

    2003-07-01

    Conventional lightning rods used in the United States have sharp tips, a practice derived from Benjamin Franklin's discovery of a means to obtain protection from lightning. However, the virtue of sharp tips for strike reception has never been established. An examination of the relevant physics shows that very strong electric fields are required above the tips of rods in order that they function as strike receptors but that the gradients of the field strength over sharp-tipped rods are so great that, at distances of a few millimeters, the local fields are often too weak for the development of upward-going streamers. In field tests, rods with rounded tips have been found to be better strike receptors than were nearby sharp-tipped rods.

  15. Health Tips for Adults

    MedlinePlus

    ... For Reporters Meetings & Workshops Follow Us Home Health Information Weight Management Health Tips for Adults Related Topics English English ... at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information ... Disease Urologic Diseases Endocrine Diseases Diet & Nutrition ...

  16. Small-tip fast recovery imaging using non-slice-selective tailored tip-up pulses and RF-spoiling

    PubMed Central

    Nielsen, Jon-Fredrik; Yoon, Daehyun; Noll, Douglas C.

    2012-01-01

    Small-tip fast recovery (STFR) imaging is a new steady-state imaging sequence that is a potential alternative to balanced steady-state free precession (bSSFP). Under ideal imaging conditions, STFR may provide comparable signal-to-noise ratio (SNR) and image contrast as bSSFP, but without signal variations due to resonance offset. STFR relies on a tailored “tip-up”, or “fast recovery”, RF pulse to align the spins with the longitudinal axis after each data readout segment. The design of the tip-up pulse is based on the acquisition of a separate off-resonance (B0) map. Unfortunately, the design of fast (a few ms) slice- or slab-selective RF pulses that accurately tailor the excitation pattern to the local B0 inhomogeneity over the entire imaging volume remains a challenging and unsolved problem. We introduce a novel implementation of STFR imaging based on non-slice-selective tip-up pulses, which simplifies the RF design problem significantly. Out-of-slice magnetization pathways are suppressed using RF-spoiling. Brain images obtained with this technique show excellent gray/white matter contrast, and point to the possibility of rapid steady-state T2/T1-weighted imaging with intrinsic suppression of cerebrospinal fluid, through-plane vessel signal, and off-resonance artifacts. In the future we expect STFR imaging to benefit significantly from parallel excitation hardware and high-order gradient shim systems. PMID:22511367

  17. Bleeding Duodenal Varices Successfully Treated with Balloon-Occluded Retrograde Transvenous Obliteration (B-RTO) Assisted by CT During Arterial Portography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsurusaki, Masakatsu, E-mail: he3m-trsk@asahi-net.or.jp; Sugimoto, Koji; Matsumoto, Shinichi

    2006-12-15

    A 60-year-old woman with massive hemorrhage from duodenal varices was transferred to our hospital for the purpose of transcatheter intervention. Although digital subtraction arterial portography could not depict the entire pathway of collateral circulation, the efferent route of the duodenal varices was clearly demonstrated on subsequent CT during arterial portography. Balloon-occluded retrograde transvenous obliteration (B-RTO) of the varices was performed via the efferent vein and achieved complete thrombosis of the varices.

  18. High-energy electron emission from metallic nano-tips driven by intense single-cycle terahertz pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Sha; Jones, R. R.

    Electrons ejected from atoms and subsequently driven to high energies in strong laser fields enable techniques from attosecond pulse generation to imaging with rescattered electrons. Analogous processes govern strong-field electron emission from nanostructures, where long wavelength radiation and large local field enhancements hold the promise for producing electrons with substantially higher energies, allowing for higher resolution time-resolved imaging. Here we report on the use of single-cycle terahertz pulses to drive electron emission from unbiased nano-tips. Energies exceeding 5 keV are observed, substantially greater than previously attained at higher drive frequencies. Despite large differences in the magnitude of the respective localmore » fields, we find that the maximum electron energies are only weakly dependent on the tip radius, for 10 nm« less

  19. High-energy electron emission from metallic nano-tips driven by intense single-cycle terahertz pulses

    DOE PAGES

    Li, Sha; Jones, R. R.

    2016-11-10

    Electrons ejected from atoms and subsequently driven to high energies in strong laser fields enable techniques from attosecond pulse generation to imaging with rescattered electrons. Analogous processes govern strong-field electron emission from nanostructures, where long wavelength radiation and large local field enhancements hold the promise for producing electrons with substantially higher energies, allowing for higher resolution time-resolved imaging. Here we report on the use of single-cycle terahertz pulses to drive electron emission from unbiased nano-tips. Energies exceeding 5 keV are observed, substantially greater than previously attained at higher drive frequencies. Despite large differences in the magnitude of the respective localmore » fields, we find that the maximum electron energies are only weakly dependent on the tip radius, for 10 nm« less

  20. Twelve tips for overnight teaching.

    PubMed

    Richards, Jeremy B; Wilcox, Susan R; Roberts, David H; Schwartzstein, Richard M

    2014-03-01

    The European Working Time Directive and the United States' duty hour restrictions have changed resident physicians' schedules, specifically increasing overnight shifts and decreasing overall time spent in the hospital. As residents' perception of night shifts is that they have little educational value, efforts to improve educational opportunities and night attending teaching are desirable. However, resources about and recommendations for best practices for overnight teaching by faculty are scarce. To provide 12 tips to highlight strategies intended to optimize attending physicians' overnight teaching skills and strategies. The tips provided are based on our experiences and reflections as in-house faculty supervising residents working overnight, by our experience and group discussions as medical educators, and the available literature. The 12 tips presented offer specific strategies to optimize attending physicians' overnight teaching for resident physicians, specifically highlighting the unique logistics, pedagogy and follow-up of overnight teaching. Preparation for teaching is important in any environment, but understanding the unique timing and circumstances associated with overnight teaching is vital to ensure that overnight teaching is effective. Acknowledging and addressing the physical and cognitive obstacles associated with overnight teaching and learning is necessary to maximize the educational value of overnight teaching.

  1. Pinning effects from substrate and AFM tip surfaces on interfacial nanobubbles

    NASA Astrophysics Data System (ADS)

    Teshima, Hideaki; Takahashi, Koji; Takata, Yasuyuki; Nishiyama, Takashi

    2017-11-01

    Measurement accuracy of atomic force microscopy (AFM) is vital to understand the mechanism of interfacial nanobubbles. In this study, we report the influence of pinning derived from both substrate and AFM tip surfaces on the measured shape of interfacial nanobubbles in peak force tapping mode. First, we pushed the nanobubbles using the AFM tip with high peak force setpoint. As a result, the deformed nanobubbles kept their flat shape for several tens of minutes. We quantitatively discuss the pinning force from substrate surface, which retains the flat shape enhancing the stability of nanobubbles. Next, we prepared three AFM tips with different wettability and measured the nanobubbles with an identical setpoint. By comparing the force curves obtained during the measurements, it seems that the (middle-)hydrophobic tips penetrated the liquid/gas interface and received repulsive force resulting from positive meniscus formed by pinning at the tip surface. In contrast, hydrophilic tip didn't penetrate the interface and received the force from the deformation of the interface of the nanobubbles. In addition, the measurements using the (middle-)hydrophobic tips led to the underestimation of the nanobubbles profile corresponding to the pinning position at the tip surfaces.

  2. Restaurant Dining: Seven Tips for Staying Gluten Free

    MedlinePlus

    GiG Education Bulletin Restaurant Dining: Seven Tips for Staying Gluten-Free Updated May 2014 Tips for Dining Away from Home 1. Selection of eating establishment. • Your success at gluten-free dining will be determined by a number of factors, including the ...

  3. Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Andrew; Butte, Manish J., E-mail: manish.butte@stanford.edu

    2014-08-04

    We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, andmore » results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.« less

  4. Filter presence and tipping paper color influence consumer perceptions of cigarettes.

    PubMed

    O'Connor, Richard J; Bansal-Travers, Maansi; Cummings, K Michael; Hammond, David; Thrasher, James F; Tworek, Cindy

    2015-12-22

    Cigarettes are marketed in a wide array of packaging and product configurations, and these may impact consumers' perceptions of product health effects and attractiveness. Filtered cigarettes are typically perceived as less hazardous and white tipping paper (as opposed to cork) often conveys 'lightness'. This study examined cigarette-related perceptions among 1220 young adult (age 18-35) current, ever, and never smokers recruited from three eastern U.S. cities (Buffalo NY, Columbia SC, Morgantown WV). Participants rated three cigarette sticks: two filtered cigarettes 85 mm in length, differing only in tipping paper color (cork versus white), and an unfiltered 70 mm cigarette. Overall, the cork-tipped cigarette was most commonly selected on taste and attractiveness, the white-tipped on least dangerous, and the unfiltered on most dangerous. Current smokers were more likely to select white-tipped (OR = 1.98) and cork-tipped (OR = 3.42) cigarettes, while ever smokers more commonly selected the cork-tipped (OR = 1.96), as most willing to try over the other products. Those willing to try the filtered white-tipped cigarette were more likely to have rated that cigarette as best tasting (OR = 11.10), attracting attention (OR = 17.91), and lowest health risk (OR = 1.94). Similarly, those willing to try cork tipped or unfiltered cigarettes rated those as best testing, attracting attention, and lowest health risk, respectively. Findings from this study demonstrate that consumer product perceptions can be influenced by elements of cigarette design, such as the presence and color of the filter tip.

  5. Tip Vortices of Isolated Wings and Helicopter Rotor Blades.

    DTIC Science & Technology

    1987-12-01

    root to tip, as expected due to the induced downwash of the tip vor- tex and wake vortex sheet. Although the three different tip-caps produce very...the inherent limitation of not being able to model the vortex wake with these equations, although the Euler formulation has in it the necessary...physics to model vorticity transport correctly. These equations basically lack the physical mecha- nism needed to generate the vortex wake . However, in

  6. Lighting: Traffic Safety Tips

    DOT National Transportation Integrated Search

    1996-01-01

    This fact sheet, NHTSA Facts: Summer 1996, discusses traffic safety tips on motor vehicle lighting, including headlights, tail lights, and signal lights. It details the cleaning of headlamps, proper aiming of headlamps, and replacement of burned out ...

  7. Measurements of Supersonic Wing Tip Vortices

    NASA Technical Reports Server (NTRS)

    Smart, Michael K.; Kalkhoran, Iraj M.; Benston, James

    1994-01-01

    An experimental survey of supersonic wing tip vortices has been conducted at Mach 2.5 using small performed 2.25 chords down-stream of a semi-span rectangular wing at angle of attack of 5 and 10 degrees. The main objective of the experiments was to determine the Mach number, flow angularity and total pressure distribution in the core region of supersonic wing tip vortices. A secondary aim was to demonstrate the feasibility of using cone probes calibrated with a numerical flow solver to measure flow characteristics at supersonic speeds. Results showed that the numerically generated calibration curves can be used for 4-hole cone probes, but were not sufficiently accurate for conventional 5-hole probes due to nose bluntness effects. Combination of 4-hole cone probe measurements with independent pitot pressure measurements indicated a significant Mach number and total pressure deficit in the core regions of supersonic wing tip vortices, combined with an asymmetric 'Burger like' swirl distribution.

  8. Laser restoration of flow in occluded ventricular shunts for pediatric neurosurgery

    NASA Astrophysics Data System (ADS)

    Christens-Barry, William A.; Guarnieri, Michael; Carson, Benjamin S.

    1998-01-01

    We have investigated the use of short pulses of infrared ((lambda) equals 2.09 micrometers ) light from a Ho:YAG laser to photofragment occlusions and restore flow in ventricular shunts, which provide the sole means of maintaining proper intracranial pressure in hydrocephalus patients. These experiments employed model tissues, a polymeric model compound, and patient explants in order to determine appropriate pulse energies and delivery rates for removal of occlusions material. Laser energy doses and rates of occlusion removal were established for these materials. Laser energy doses that do not damage the shunt device or surrounding tissue were identified. Optical fibers (25 ga. or smaller) can be introduced through the dome of current shunt devices and threaded to the occlusion site. Clinical application will require the continued development of an introducer tool for the transcutaneous insertion of the optical fiber into the shunt device and irrigation techniques for removing the occlusion detritus generated by photofragmentation treatment. Using this approach, a minimally invasive and benign procedure for in situ restoration of flow in occluded neurological implant devices becomes possible.

  9. Eye Tracking of Occluded Self-Moved Targets: Role of Haptic Feedback and Hand-Target Dynamics.

    PubMed

    Danion, Frederic; Mathew, James; Flanagan, J Randall

    2017-01-01

    Previous studies on smooth pursuit eye movements have shown that humans can continue to track the position of their hand, or a target controlled by the hand, after it is occluded, thereby demonstrating that arm motor commands contribute to the prediction of target motion driving pursuit eye movements. Here, we investigated this predictive mechanism by manipulating both the complexity of the hand-target mapping and the provision of haptic feedback. Two hand-target mappings were used, either a rigid (simple) one in which hand and target motion matched perfectly or a nonrigid (complex) one in which the target behaved as a mass attached to the hand by means of a spring. Target animation was obtained by asking participants to oscillate a lightweight robotic device that provided (or not) haptic feedback consistent with the target dynamics. Results showed that as long as 7 s after target occlusion, smooth pursuit continued to be the main contributor to total eye displacement (∼60%). However, the accuracy of eye-tracking varied substantially across experimental conditions. In general, eye-tracking was less accurate under the nonrigid mapping, as reflected by higher positional and velocity errors. Interestingly, haptic feedback helped to reduce the detrimental effects of target occlusion when participants used the nonrigid mapping, but not when they used the rigid one. Overall, we conclude that the ability to maintain smooth pursuit in the absence of visual information can extend to complex hand-target mappings, but the provision of haptic feedback is critical for the maintenance of accurate eye-tracking performance.

  10. Eye Tracking of Occluded Self-Moved Targets: Role of Haptic Feedback and Hand-Target Dynamics

    PubMed Central

    Mathew, James

    2017-01-01

    Abstract Previous studies on smooth pursuit eye movements have shown that humans can continue to track the position of their hand, or a target controlled by the hand, after it is occluded, thereby demonstrating that arm motor commands contribute to the prediction of target motion driving pursuit eye movements. Here, we investigated this predictive mechanism by manipulating both the complexity of the hand-target mapping and the provision of haptic feedback. Two hand-target mappings were used, either a rigid (simple) one in which hand and target motion matched perfectly or a nonrigid (complex) one in which the target behaved as a mass attached to the hand by means of a spring. Target animation was obtained by asking participants to oscillate a lightweight robotic device that provided (or not) haptic feedback consistent with the target dynamics. Results showed that as long as 7 s after target occlusion, smooth pursuit continued to be the main contributor to total eye displacement (∼60%). However, the accuracy of eye-tracking varied substantially across experimental conditions. In general, eye-tracking was less accurate under the nonrigid mapping, as reflected by higher positional and velocity errors. Interestingly, haptic feedback helped to reduce the detrimental effects of target occlusion when participants used the nonrigid mapping, but not when they used the rigid one. Overall, we conclude that the ability to maintain smooth pursuit in the absence of visual information can extend to complex hand-target mappings, but the provision of haptic feedback is critical for the maintenance of accurate eye-tracking performance. PMID:28680964

  11. Homogeneous nucleation of water in argon. Nucleation rate computation from molecular simulations of TIP4P and TIP4P/2005 water model.

    PubMed

    Dumitrescu, Lucia R; Smeulders, David M J; Dam, Jacques A M; Gaastra-Nedea, Silvia V

    2017-02-28

    Molecular dynamics (MD) simulations were conducted to study nucleation of water at 350 K in argon using TIP4P and TIP4P/2005 water models. We found that the stability of any cluster, even if large, strongly depends on the energetic interactions with its vicinity, while the stable clusters change their composition almost entirely during nucleation. Using the threshold method, direct nucleation rates are obtained. Our nucleation rates are found to be 1.08×10 27 cm -3 s -1 for TIP4P and 2.30×10 27 cm -3 s -1 for TIP4P/2005. The latter model prescribes a faster dynamics than the former, with a nucleation rate two times larger due to its higher electrostatic charges. The non-equilibrium water densities derived from simulations and state-of-art equilibrium parameters from Vega and de Miguel [J. Chem. Phys. 126, 154707 (2007)] are used for the classical nucleation theory (CNT) prediction. The CNT overestimates our results for both water models, where TIP4P/2005 shows largest discrepancy. Our results complement earlier data at high nucleation rates and supersaturations in the Hale plot [Phys. Rev. A 33, 4156 (1986)], and are consistent with MD data on the SPC/E and the TIP4P/2005 model.

  12. NMR identification of the binding surfaces involved in the Salmonella and Shigella Type III secretion tip-translocon protein-protein interactions.

    PubMed

    McShan, Andrew C; Kaur, Kawaljit; Chatterjee, Srirupa; Knight, Kevin M; De Guzman, Roberto N

    2016-08-01

    The type III secretion system (T3SS) is essential for the pathogenesis of many bacteria including Salmonella and Shigella, which together are responsible for millions of deaths worldwide each year. The structural component of the T3SS consists of the needle apparatus, which is assembled in part by the protein-protein interaction between the tip and the translocon. The atomic detail of the interaction between the tip and the translocon proteins is currently unknown. Here, we used NMR methods to identify that the N-terminal domain of the Salmonella SipB translocon protein interacts with the SipD tip protein at a surface at the distal region of the tip formed by the mixed α/β domain and a portion of its coiled-coil domain. Likewise, the Shigella IpaB translocon protein and the IpaD tip protein interact with each other using similar surfaces identified for the Salmonella homologs. Furthermore, removal of the extreme N-terminal residues of the translocon protein, previously thought to be important for the interaction, had little change on the binding surface. Finally, mutations at the binding surface of SipD reduced invasion of Salmonella into human intestinal epithelial cells. Together, these results reveal the binding surfaces involved in the tip-translocon protein-protein interaction and advance our understanding of the assembly of the T3SS needle apparatus. Proteins 2016; 84:1097-1107. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Holographic quantitative imaging of sample hidden by turbid medium or occluding objects

    NASA Astrophysics Data System (ADS)

    Bianco, V.; Miccio, L.; Merola, F.; Memmolo, P.; Gennari, O.; Paturzo, Melania; Netti, P. A.; Ferraro, P.

    2015-03-01

    Digital Holography (DH) numerical procedures have been developed to allow imaging through turbid media. A fluid is considered turbid when dispersed particles provoke strong light scattering, thus destroying the image formation by any standard optical system. Here we show that sharp amplitude imaging and phase-contrast mapping of object hidden behind turbid medium and/or occluding objects are possible in harsh noise conditions and with a large field-of view by Multi-Look DH microscopy. In particular, it will be shown that both amplitude imaging and phase-contrast mapping of cells hidden behind a flow of Red Blood Cells can be obtained. This allows, in a noninvasive way, the quantitative evaluation of living processes in Lab on Chip platforms where conventional microscopy techniques fail. The combination of this technique with endoscopic imaging can pave the way for the holographic blood vessel inspection, e.g. to look for settled cholesterol plaques as well as blood clots for a rapid diagnostics of blood diseases.

  14. Twelve tips for "flipping" the classroom.

    PubMed

    Moffett, Jennifer

    2015-04-01

    The flipped classroom is a pedagogical model in which the typical lecture and homework elements of a course are reversed. The following tips outline the steps involved in making a successful transition to a flipped classroom approach. The tips are based on the available literature alongside the author's experience of using the approach in a medical education setting. Flipping a classroom has a number of potential benefits, for example increased educator-student interaction, but must be planned and implemented carefully to support effective learning.

  15. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section 870.2870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2870 Catheter tip...

  16. Aerodynamic effect of a honeycomb rotor tip shroud on a 50.8-centimeter-tip-diameter core turbine

    NASA Technical Reports Server (NTRS)

    Moffitt, T. P.; Whitney, W. J.

    1983-01-01

    A 50.8-cm-tip-diameter turbine equipped with a rotor tip shroud of hexagonal cell (or honeycomb) cross section has been tested in warm air (416 K) for a range of shroud coolant to primary flow rates. Test results were also obtained for the same turbine operated with a solid shroud for comparison. The results showed that the combined effect of the honeycomb shroud and the coolant flow was to cause a reduction of 2.8 points in efficiency at design speed, pressure ratio, and coolant flow rate. With the coolant system inactivated, the honeycomb shroud caused a decrease in efficiency of 2.3 points. These results and those obtained from a small reference turbine indicate that the dominant factor governing honeycomb tip shroud loss is the ratio of honeycomb depth to blade span. The loss results of the two shrouds could be correlated on this basis. The same honeycomb and coolant effects are expected to occur for the hot (2200 K) version of this turbine.

  17. Tip-enhanced Raman mapping with top-illumination AFM.

    PubMed

    Chan, K L Andrew; Kazarian, Sergei G

    2011-04-29

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of ∼ 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  18. Technology Tips: A Potpourri.

    ERIC Educational Resources Information Center

    Cuoco, Albert A.; And Others, Eds.

    1994-01-01

    Contains tips from readers about using technology in the classroom, including notebook computers, classroom sets of calculators, geometry software, LOGO software, publisher discounts, curriculum materials in CD-ROM, and volunteer help in computers and computer networking for schools. (MKR)

  19. Tip-Enhanced Photoinduced Electron Transfer and Ionization on Vertical Silicon Nanowires.

    PubMed

    Chen, Xiaoming; Wang, Tao; Lin, Leimiao; Wo, Fangjie; Liu, Yaqin; Liang, Xiao; Ye, Hui; Wu, Jianmin

    2018-05-02

    Nanostructured semiconductors are one of the most potent candidates for matrix-free laser desorption/ionization mass spectrometric (LDI-MS) analysis of low-molecular-weight molecules. Herein, the enhanced photoinduced electron transfer and LDI on the tip of a vertical silicon nanowire (SiNW) array were investigated. Theoretical simulation and LDI detection of indigo and isatin molecules in negative ion mode revealed that the electric field can be enhanced on the tip end of SiNWs, thereby promoting the energy and electron transfer to the analytes adsorbed on the tip of SiNWs. On the basis of this finding, a tip-contact sampling method coupled with LDI-MS detection was established. In this strategy, the tip of SiNWs can be regarded as microextraction heads for the sampling of molecules when they come in contact with analytes. Impression of skin, tissue, and pericarp on the vertical SiNW array can effectively transfer endogenous metabolites or exogenous substances onto the tip. Upon laser irradiation, the adsorbed molecules on the SiNW tip can be efficiently ionized and detected in negative ion mode because of the tip-enhanced electron transfer and LDI effect. We believe this work may significantly expand the application of LDI-MS in various fields.

  20. A numerical study of crack tip constraint in ductile single crystals

    NASA Astrophysics Data System (ADS)

    Patil, Swapnil D.; Narasimhan, R.; Mishra, R. K.

    In this work, the effect of crack tip constraint on near-tip stress and deformation fields in a ductile FCC single crystal is studied under mode I, plane strain conditions. To this end, modified boundary layer simulations within crystal plasticity framework are performed, neglecting elastic anisotropy. The first and second terms of the isotropic elastic crack tip field, which are governed by the stress intensity factor K and T-stress, are prescribed as remote boundary conditions and solutions pertaining to different levels of T-stress are generated. It is found that the near-tip deformation field, especially, the development of kink or slip shear bands, is sensitive to the constraint level. The stress distribution and the size and shape of the plastic zone near the crack tip are also strongly influenced by the level of T-stress, with progressive loss of crack tip constraint occurring as T-stress becomes more negative. A family of near-tip fields is obtained which are characterized by two terms (such as K and T or J and a constraint parameter Q) as in isotropic plastic solids.

  1. Advanced ceramic material for high temperature turbine tip seals

    NASA Technical Reports Server (NTRS)

    Solomon, N. G.; Vogan, J. W.

    1978-01-01

    Ceramic material systems are being considered for potential use as turbine blade tip gas path seals at temperatures up to 1370 1/4 C. Silicon carbide and silicon nitride structures were selected for study since an initial analysis of the problem gave these materials the greatest potential for development into a successful materials system. Segments of silicon nitride and silicon carbide materials over a range of densities, processed by various methods, a honeycomb structure of silicon nitride and ceramic blade tip inserts fabricated from both materials by hot pressing were tested singly and in combination. The evaluations included wear under simulated engine blade tip rub conditions, thermal stability, impact resistance, machinability, hot gas erosion and feasibility of fabrication into engine components. The silicon nitride honeycomb and low-density silicon carbide using a selected grain size distribution gave the most promising results as rub-tolerant shroud liners. Ceramic blade tip inserts made from hot-pressed silicon nitride gave excellent test results. Their behavior closely simulated metal tips. Wear was similar to that of metals but reduced by a factor of six.

  2. Sharpening of field emitter tips using high-energy ions

    DOEpatents

    Musket, Ronald G.

    1999-11-30

    A process for sharpening arrays of field emitter tips of field emission cathodes, such as found in field-emission, flat-panel video displays. The process uses sputtering by high-energy (more than 30 keV) ions incident along or near the longitudinal axis of the field emitter to sharpen the emitter with a taper from the tip or top of the emitter down to the shank of the emitter. The process is particularly applicable to sharpening tips of emitters having cylindrical or similar (e.g., pyramidal) symmetry. The process will sharpen tips down to radii of less than 12 nm with an included angle of about 20 degrees. Because the ions are incident along or near the longitudinal axis of each emitter, the tips of gated arrays can be sharpened by high-energy ion beams rastered over the arrays using standard ion implantation equipment. While the process is particularly applicable for sharpening of arrays of field emitters in field-emission flat-panel displays, it can be effectively utilized in the fabrication of other vacuum microelectronic devices that rely on field emission of electrons.

  3. Corrugated metal-coated tapered tip for scanning near-field optical microscope.

    PubMed

    Antosiewicz, Tomasz J; Szoplik, Tomasz

    2007-08-20

    This paper addresses an important issue of light throughput of a metal-coated tapered tip for scanning near-field microscope (SNOM). Corrugations of the interface between the fiber core and metal coating in the form of parallel grooves of different profiles etched in the core considerably increase the energy throughput. In 2D FDTD simulations in the Cartesian coordinates we calculate near-field light emitted from such tips. For a certain wavelength range total intensity of forward emission from the corrugated tip is 10 times stronger than that from a classical tapered tip. When realized in practice the idea of corrugated tip may lead up to twice better resolution of SNOM.

  4. Identifying passivated dynamic force microscopy tips on H:Si(100)

    NASA Astrophysics Data System (ADS)

    Sharp, Peter; Jarvis, Sam; Woolley, Richard; Sweetman, Adam; Kantorovich, Lev; Pakes, Chris; Moriarty, Philip

    2012-06-01

    The chemical reactivity of the tip plays a central role in image formation in dynamic force microscopy, but in very many cases the state of the probe is a key experimental unknown. We show here that an H-terminated and thus chemically unreactive tip can be readily identified via characteristic imaging and spectroscopic (F(z)) signatures, including, in particular, contrast inversion, on hydrogen-passivated Si(100). We determine the tip apex termination by comparing site-specific difference force curves with the results of density functional theory, providing a clear protocol for the identification of chemically unreactive tips on silicon surfaces.

  5. Tipping elements in the Arctic marine ecosystem.

    PubMed

    Duarte, Carlos M; Agustí, Susana; Wassmann, Paul; Arrieta, Jesús M; Alcaraz, Miquel; Coello, Alexandra; Marbà, Núria; Hendriks, Iris E; Holding, Johnna; García-Zarandona, Iñigo; Kritzberg, Emma; Vaqué, Dolors

    2012-02-01

    The Arctic marine ecosystem contains multiple elements that present alternative states. The most obvious of which is an Arctic Ocean largely covered by an ice sheet in summer versus one largely devoid of such cover. Ecosystems under pressure typically shift between such alternative states in an abrupt, rather than smooth manner, with the level of forcing required for shifting this status termed threshold or tipping point. Loss of Arctic ice due to anthropogenic climate change is accelerating, with the extent of Arctic sea ice displaying increased variance at present, a leading indicator of the proximity of a possible tipping point. Reduced ice extent is expected, in turn, to trigger a number of additional tipping elements, physical, chemical, and biological, in motion, with potentially large impacts on the Arctic marine ecosystem.

  6. Hand interception of occluded motion in humans: a test of model-based vs. on-line control.

    PubMed

    La Scaleia, Barbara; Zago, Myrka; Lacquaniti, Francesco

    2015-09-01

    Two control schemes have been hypothesized for the manual interception of fast visual targets. In the model-free on-line control, extrapolation of target motion is based on continuous visual information, without resorting to physical models. In the model-based control, instead, a prior model of target motion predicts the future spatiotemporal trajectory. To distinguish between the two hypotheses in the case of projectile motion, we asked participants to hit a ball that rolled down an incline at 0.2 g and then fell in air at 1 g along a parabola. By varying starting position, ball velocity and trajectory differed between trials. Motion on the incline was always visible, whereas parabolic motion was either visible or occluded. We found that participants were equally successful at hitting the falling ball in both visible and occluded conditions. Moreover, in different trials the intersection points were distributed along the parabolic trajectories of the ball, indicating that subjects were able to extrapolate an extended segment of the target trajectory. Remarkably, this trend was observed even at the very first repetition of movements. These results are consistent with the hypothesis of model-based control, but not with on-line control. Indeed, ball path and speed during the occlusion could not be extrapolated solely from the kinematic information obtained during the preceding visible phase. The only way to extrapolate ball motion correctly during the occlusion was to assume that the ball would fall under gravity and air drag when hidden from view. Such an assumption had to be derived from prior experience. Copyright © 2015 the American Physiological Society.

  7. Sports Dehydration Safety Tips

    MedlinePlus

    Sports Dehydration Safety Tips Everything you need to know to keep your kids safe from dehydration when playing sports. To keep kids in top ... to stay hydrated by drinking plenty of fluids. Dehydration occurs when a body loses more water than ...

  8. Brakes: Traffic Safety Tips

    DOT National Transportation Integrated Search

    1996-01-01

    This fact sheet, NHTSA Facts: Summer 1996, describes traffic safety tips about brakes. It discusses drum brakes, disc brakes, and antilock braking systsms. It notes that there are government standards for brakes, and describes how to take care of bra...

  9. Defining tipping points for social-ecological systems scholarship—an interdisciplinary literature review

    NASA Astrophysics Data System (ADS)

    Milkoreit, Manjana; Hodbod, Jennifer; Baggio, Jacopo; Benessaiah, Karina; Calderón-Contreras, Rafael; Donges, Jonathan F.; Mathias, Jean-Denis; Rocha, Juan Carlos; Schoon, Michael; Werners, Saskia E.

    2018-03-01

    The term tipping point has experienced explosive popularity across multiple disciplines over the last decade. Research on social-ecological systems (SES) has contributed to the growth and diversity of the term’s use. The diverse uses of the term obscure potential differences between tipping behavior in natural and social systems, and issues of causality across natural and social system components in SES. This paper aims to create the foundation for a discussion within the SES research community about the appropriate use of the term tipping point, especially the relatively novel term ‘social tipping point.’ We review existing literature on tipping points and similar concepts (e.g. regime shifts, critical transitions) across all spheres of science published between 1960 and 2016 with a special focus on a recent and still small body of work on social tipping points. We combine quantitative and qualitative analyses in a bibliometric approach, rooted in an expert elicitation process. We find that the term tipping point became popular after the year 2000—long after the terms regime shift and critical transition—across all spheres of science. We identify 23 distinct features of tipping point definitions and their prevalence across disciplines, but find no clear taxonomy of discipline-specific definitions. Building on the most frequently used features, we propose definitions for tipping points in general and social tipping points in SES in particular.

  10. Anisotropic adhesion properties of triangular-tip-shaped micropillars.

    PubMed

    Kwak, Moon Kyu; Jeong, Hoon Eui; Bae, Won Gyu; Jung, Ho-Sup; Suh, Kahp Y

    2011-08-22

    Directional dry adhesive microstructures consisting of high-density triangular-tip-shaped micropillars are described. The wide-tip structures allow for unique directional shear adhesion properties with respect to the peeling direction, along with relatively high normal adhesion. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  12. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  13. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  14. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  15. Ultrafast time-resolved photoemission of a metallic tip/substrate junction

    NASA Astrophysics Data System (ADS)

    Meng, Xiang; Jin, Wencan; Yang, Hao; Dadap, Jerry; Osgood, Richard; Camillone, Nicholas, III

    The strong near-field enhancement of metallic-tip nanostructures has attracted great interest in scanning microscopy techniques, such as surface-enhanced Raman scattering, near-field scanning optical microscopy and tip-enhanced nonlinear imaging. In this talk, we use a full vectorial 3D-FDTD method to investigate the spatial characteristics of the optical field confinement and localization between a tungsten nanoprobe and an infinite planar silver substrate, with two-color ultrafast laser excitation scheme. The degree of two-color excited field enhancement, geometry dependence, the exact mechanism of optical tip-substrate coupling and tip-substrate plasmon resonances are significant in understanding the electrodynamical responses at tip-substrate junction. The demonstrated measurements with subpicosecond time and subnanometer spatial resolution suggest a new approach to ultrafast time-resolved measurements of surface electron dynamics. DE-FG 02-90-ER-14104; DE-FG 02-04-ER-46157.

  16. Flowfield and heat transfer past an unshrouded gas turbine blade tip with different shapes

    NASA Astrophysics Data System (ADS)

    Liu, Jian-Jun; Li, Peng; Zhang, Chao; An, Bai-Tao

    2013-04-01

    This paper describes the numerical investigations of flow and heat transfer in an unshrouded turbine rotor blade of a heavy duty gas turbine with four tip configurations. By comparing the calculated contours of heat transfer coefficients on the flat tip of the HP turbine rotor blade in the GE-E3 aircraft engine with the corresponding experimental data, the κ-ω turbulence model was chosen for the present numerical simulations. The inlet and outlet boundary conditions for the turbine rotor blade are specified as the real gas turbine, which were obtained from the 3D full stage simulations. The rotor blade and the hub endwall are rotary and the casing is stationary. The influences of tip configurations on the tip leakage flow and blade tip heat transfer were discussed. It's showed that the different tip configurations changed the leakage flow patterns and the pressure distributions on the suction surface near the blade tip. Compared with the flat tip, the total pressure loss caused by the leakage flow was decreased for the full squealer tip and pressure side squealer tip, while increased for the suction side squealer tip. The suction side squealer tip results in the lowest averaged heat transfer coefficient on the blade tip compared to the other tip configurations.

  17. Thulium fiber laser recanalization of occluded ventricular catheters in an ex vivo tissue model

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Hardy, Luke A.; McLanahan, C. Scott; Fried, Nathaniel M.

    2017-04-01

    Hydrocephalus is a chronic medical condition that occurs in individuals who are unable to reabsorb cerebrospinal fluid (CSF) created within the ventricles of the brain. Treatment requires excess CSF to be diverted from the ventricles to another part of the body, where it can be returned to the vascular system via a shunt system beginning with a catheter within the ventricle. Catheter failures due to occlusion by brain tissues commonly occur and require surgical replacement of the catheter. In this preliminary study, minimally invasive clearance of occlusions is explored using an experimental thulium fiber laser (TFL), with comparison to a conventional holmium: yttrium aluminium garnet (YAG) laser. The TFL utilizes smaller optical fibers (<200-μm OD) compared with holmium laser (>450-μm OD), providing critical extra cross-sectional space within the 1.2-mm-inner-diameter ventricular catheter for simultaneous application of an endoscope for image guidance and a saline irrigation tube for visibility and safety. TFL ablation rates using 100-μm core fiber, 33-mJ pulse energy, 500-μs pulse duration, and 20- to 200-Hz pulse rates were compared to holmium laser using a 270-μm core fiber, 325-mJ, 300-μs, and 10 Hz. A tissue occluded catheter model was prepared using coagulated egg white within clear silicone tubing. An optimal TFL pulse rate of 50 Hz was determined, with an ablation rate of 150 μm/s and temperature rise outside the catheter of ˜10°C. High-speed camera images were used to explore the mechanism for removal of occlusions. Image guidance using a miniature, 0.7-mm outer diameter, 10,000 pixel endoscope was explored to improve procedure safety. With further development, simultaneous application of TFL with small fibers, miniature endoscope for image guidance, and irrigation tube for removal of tissue debris may provide a safe, efficient, and minimally invasive method of clearing occluded catheters in the treatment of hydrocephalus.

  18. 29 CFR 531.59 - The tip wage credit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false The tip wage credit. 531.59 Section 531.59 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR REGULATIONS WAGE PAYMENTS UNDER THE FAIR LABOR STANDARDS ACT OF 1938 Interpretations Payment of Wages to Tipped Employees...

  19. Long Term Effects of Percutaneous Coronary Intervention of the Totally Occluded Infarct-Related Artery in the Subacute Phase after Myocardial Infarction

    PubMed Central

    Hochman, Judith S; Reynolds, Harmony R; Džavík, Vladimír; Buller, Christopher E; Ruzyllo, Witold; Sadowski, Zygmunt P; Maggioni, Aldo P; Carvalho, Antonio C; Rankin, James M.; White, Harvey D.; Goldberg, Suzanne; Forman, Sandra A; Mark, Daniel B; Lamas, Gervasio A

    2011-01-01

    Background Despite observations suggesting a benefit for late opening of occluded infarct-related arteries (IRA) post-myocardial infarction (MI), the Occluded Artery Trial (OAT) demonstrated no reduction in the composite of death, reinfarction and class IV heart failure (HF) over 2.9-yearmean follow-up. Follow-up was extended to determine whether late trends would favor either treatment group. Methods and Results OAT randomized 2201 stable patients with IRA occlusion >24hours (calendar days3-28) after MI. Severe inducible ischemia, rest angina, class III-IV HF and 3-vessel/left main disease were excluded. We conducted extended followed up of enrolled patients for an additional 3 years for the primary endpoint and angina (6-year median survivor follow up, longest 9 years, 12,234 patient-years).Rates of the primary endpoint (HR 1.06, 95% CI 0.88-1.28), fatal and nonfatal MI (HR 1.25, 95% CI 0.89-1.75), death and class IV HF were similar for PCI vs. MED groups. No interaction between baseline characteristics and treatment group on outcomes were observed. The vast majority of patients at each follow-up visit did not report angina. There was less angina in the PCI group through early in follow-up; by 3 years the between group difference was consistently <4 patients per 100 treated and not significantly different though there was a trend toward less angina in the PCI group at 3 and 5 years. The 7-year rate of PCI of the IRA during follow up was 11.1% for the PCI group compared to 14.7% for the MED group (HR 0.79, 95% CI 0.61-1.01. p=0.06). Conclusions Extended follow up of the OAT cohort provides robust evidence for no reduction of long-term rates of clinical events after routine PCI in stable patients with an occluded IRA and without severe inducible ischemia in the subacute phase post-MI. PMID:22025606

  20. Oil-flow study of a Space Shuttle orbiter tip-fin controller

    NASA Technical Reports Server (NTRS)

    Helms, V. T., III

    1983-01-01

    Possible use of tip-fin controllers instead of a vertical tail on advanced winged entry vehicles was examined. Elimination of the vertical tail and using tip-fins offers the advantages of positive yaw control at high angles of attack and a potential weight savings. Oil-flow technique was used to obtain surface flow patterns on a tip-fin installed on a 0.01-scale Space Shuttle orbiter model for the purpose of assessing the extent of flow interference effects on the wing and tip-fin which might lead to serious heating problems. Tests were conducted in air at Mach 10 for a free-stream Reynolds numbers of .000113 at 20, 30, and 40 degree angle of attack and sideslip angles of 0 and 2 degree. Elevon deflections of -10, 0, and 10 degree and tip-fin control-surface deflections of 0, 20, and 40 degree were employed. Test results were also used to aid in the interpretation of heating data obtained on a Shuttle orbiter tip-fin on another model in a different facility. A limited comparison of oil-flow patterns and heat-transfer data is included. It was determined that elevon deflection angles from -10 to 10 degree and sideslip angles up to 2 degree have very little effect on tip-fin surface flow patterns. Also, there is a minimum of interference between the tip-fin and the wing. The most significant flow interactions occur on the tip-fin onboard surface as a result of its control-surface deflections.

  1. Tips for Daily Living

    MedlinePlus

    ... Stories of Returning to School or Work Tough Work If You Can Get It Home Modifications Mental Health Tips for Maintaining a Positive Outlook and Well-Being Recreation Can Increase Awareness Improving Memory Submitting Your Story Stroke families put the ‘connection’ ...

  2. An investigation of rotor tip leakage flows in the rear-block of a multistage compressor

    NASA Astrophysics Data System (ADS)

    Brossman, John Richard

    measurements during this investigation. A detailed investigation and sensitivity analysis of the inlet flow field found the influence by the inlet total temperature profile was important to performance calculations. This finding was significant and original as previous investigations have been conducted on low-speed machines where there is minimal temperature rise. The steady state performance of the baseline 1.5% tip clearance case was outlined at design speed and three off-design speeds. The leakage flow from the rear seal, the inlet flow field and a thermal boundary condition over the casing was recorded at each operating point. Stage 1 was found to be the limiting stage independent of speed. Few datasets exist on multistage compressor performance with full boundary condition definitions, especially with off-design operating points presenting this as a unique dataset for CFD comparison. The detailed unsteady pressure measurements were conducted over Rotor 1 at design and a near-stall operating condition to characterize the leakage trajectory and position. The leakage flow initial point closer to the leading edge and trajectory angle increased at the higher loading condition. The over-the-rotor static pressure field on Rotor 1 indicated similar trends between the computational model and the leakage trajectory.

  3. Particle Filtering with Region-based Matching for Tracking of Partially Occluded and Scaled Targets*

    PubMed Central

    Nakhmani, Arie; Tannenbaum, Allen

    2012-01-01

    Visual tracking of arbitrary targets in clutter is important for a wide range of military and civilian applications. We propose a general framework for the tracking of scaled and partially occluded targets, which do not necessarily have prominent features. The algorithm proposed in the present paper utilizes a modified normalized cross-correlation as the likelihood for a particle filter. The algorithm divides the template, selected by the user in the first video frame, into numerous patches. The matching process of these patches by particle filtering allows one to handle the target’s occlusions and scaling. Experimental results with fixed rectangular templates show that the method is reliable for videos with nonstationary, noisy, and cluttered background, and provides accurate trajectories in cases of target translation, scaling, and occlusion. PMID:22506088

  4. Neural network approximation of tip-abrasion effects in AFM imaging

    NASA Astrophysics Data System (ADS)

    Bakucz, Peter; Yacoot, Andrew; Dziomba, Thorsten; Koenders, Ludger; Krüger-Sehm, Rolf

    2008-06-01

    The abrasion (wear) of tips used in scanning force microscopy (SFM) directly influences SFM image quality and is therefore of great relevance to quantitative SFM measurements. The increasing implementation of automated SFM measurement schemes has become a strong driving force for increasing efforts towards the prediction of tip wear, as it needs to be ensured that the probe is exchanged before a level of tip wear is reached that adversely affects the measurement quality. In this paper, we describe the identification of tip abrasion in a system of SFM measurements. We attempt to model the tip-abrasion process as a concatenation of a mapping from the measured AFM data to a regression vector and a nonlinear mapping from the regressor space to the output space. The mapping is formed as a basis function expansion. Feedforward neural networks are used to approximate this mapping. The one-hidden layer network gave a good quality of fit for the training and test sets for the tip-abrasion system. We illustrate our method with AFM measurements of both fine periodic structures and randomly oriented sharp features and compare our neural network results with those obtained using other methods.

  5. High Speed Imaging of Cavitation around Dental Ultrasonic Scaler Tips.

    PubMed

    Vyas, Nina; Pecheva, Emilia; Dehghani, Hamid; Sammons, Rachel L; Wang, Qianxi X; Leppinen, David M; Walmsley, A Damien

    2016-01-01

    Cavitation occurs around dental ultrasonic scalers, which are used clinically for removing dental biofilm and calculus. However it is not known if this contributes to the cleaning process. Characterisation of the cavitation around ultrasonic scalers will assist in assessing its contribution and in developing new clinical devices for removing biofilm with cavitation. The aim is to use high speed camera imaging to quantify cavitation patterns around an ultrasonic scaler. A Satelec ultrasonic scaler operating at 29 kHz with three different shaped tips has been studied at medium and high operating power using high speed imaging at 15,000, 90,000 and 250,000 frames per second. The tip displacement has been recorded using scanning laser vibrometry. Cavitation occurs at the free end of the tip and increases with power while the area and width of the cavitation cloud varies for different shaped tips. The cavitation starts at the antinodes, with little or no cavitation at the node. High speed image sequences combined with scanning laser vibrometry show individual microbubbles imploding and bubble clouds lifting and moving away from the ultrasonic scaler tip, with larger tip displacement causing more cavitation.

  6. High Speed Imaging of Cavitation around Dental Ultrasonic Scaler Tips

    PubMed Central

    Vyas, Nina; Pecheva, Emilia; Dehghani, Hamid; Sammons, Rachel L.; Wang, Qianxi X.; Leppinen, David M.; Walmsley, A. Damien

    2016-01-01

    Cavitation occurs around dental ultrasonic scalers, which are used clinically for removing dental biofilm and calculus. However it is not known if this contributes to the cleaning process. Characterisation of the cavitation around ultrasonic scalers will assist in assessing its contribution and in developing new clinical devices for removing biofilm with cavitation. The aim is to use high speed camera imaging to quantify cavitation patterns around an ultrasonic scaler. A Satelec ultrasonic scaler operating at 29 kHz with three different shaped tips has been studied at medium and high operating power using high speed imaging at 15,000, 90,000 and 250,000 frames per second. The tip displacement has been recorded using scanning laser vibrometry. Cavitation occurs at the free end of the tip and increases with power while the area and width of the cavitation cloud varies for different shaped tips. The cavitation starts at the antinodes, with little or no cavitation at the node. High speed image sequences combined with scanning laser vibrometry show individual microbubbles imploding and bubble clouds lifting and moving away from the ultrasonic scaler tip, with larger tip displacement causing more cavitation. PMID:26934340

  7. Fracture mechanics by three-dimensional crack-tip synchrotron X-ray microscopy

    PubMed Central

    Withers, P. J.

    2015-01-01

    To better understand the relationship between the nucleation and growth of defects and the local stresses and phase changes that cause them, we need both imaging and stress mapping. Here, we explore how this can be achieved by bringing together synchrotron X-ray diffraction and tomographic imaging. Conventionally, these are undertaken on separate synchrotron beamlines; however, instruments capable of both imaging and diffraction are beginning to emerge, such as ID15 at the European Synchrotron Radiation Facility and JEEP at the Diamond Light Source. This review explores the concept of three-dimensional crack-tip X-ray microscopy, bringing them together to probe the crack-tip behaviour under realistic environmental and loading conditions and to extract quantitative fracture mechanics information about the local crack-tip environment. X-ray diffraction provides information about the crack-tip stress field, phase transformations, plastic zone and crack-face tractions and forces. Time-lapse CT, besides providing information about the three-dimensional nature of the crack and its local growth rate, can also provide information as to the activation of extrinsic toughening mechanisms such as crack deflection, crack-tip zone shielding, crack bridging and crack closure. It is shown how crack-tip microscopy allows a quantitative measure of the crack-tip driving force via the stress intensity factor or the crack-tip opening displacement. Finally, further opportunities for synchrotron X-ray microscopy are explored. PMID:25624521

  8. Materials for advanced turbine engines. Volume 1: Advanced blade tip seal system

    NASA Technical Reports Server (NTRS)

    Zelahy, J. W.; Fairbanks, N. P.

    1982-01-01

    Project 3, the subject of this technical report, was structured toward the successful engine demonstration of an improved-efficiency, long-life, tip-seal system for turbine blades. The advanced tip-seal system was designed to maintain close operating clearances between turbine blade tips and turbine shrouds and, at the same time, be resistant to environmental effects including high-temperature oxidation, hot corrosion, and thermal cycling. The turbine blade tip comprised an environmentally resistant, activated-diffussion-bonded, monocrystal superalloy combined with a thin layer of aluminium oxide abrasive particles entrapped in an electroplated NiCr matrix. The project established the tip design and joint location, characterized the single-crystal tip alloy and abrasive tip treatment, and established the manufacturing and quality-control plans required to fully process the blades. A total of 171 blades were fully manufactured, and 100 were endurance and performance engine-tested.

  9. 26 CFR 31.3401(a)(16)-1 - Tips.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE EMPLOYMENT TAXES AND COLLECTION OF INCOME TAX AT SOURCE Collection of Income Tax at Source § 31.3401(a)(16)-1 Tips. Tips paid to an employee are excepted from wages and hence...

  10. STEM TIPS: Supporting the Beginning Secondary STEM Teacher

    ERIC Educational Resources Information Center

    Jones, Griff; Dana, Thomas; LaFramenta, Joanne; Adams, Thomasenia Lott; Arnold, Jason Dean

    2016-01-01

    The STEM TIPS mobile-ready support platform gives institutions or school districts the ability to provide immediate and customized mentoring to teachers through multiple tiers of web-based support and resources. Using the results of a needs assessment, STEM TIPS was created and launched in partnership with 18 Florida school districts. Further…

  11. Tip moth parasitoids and pesticides: Are they compatible?

    Treesearch

    Kenneth W. McCravy; Mark J. Dalusky; C. Wayne Berisford

    1999-01-01

    Effects of herbicide and insecticide applications on parasitism of the Nantucket pine tip moth, Rhyacionia frustrana (Comstock) were examined in 2-yr-old loblolly pine (Pinus taeda L.) plantations in Georgia. Total parasitism rates varied significantly among tip moth generations, but there were no differences in parasitism rates between herbicide-treated and untreated...

  12. Acute Increase in Hepatic Arterial Flow During TIPS Identified by Intravascular Flow Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radeleff, Boris, E-mail: Boris_Radeleff@med.uni-heidelberg.de; Sommer, Christof-Matthias; Heye, Tobias

    2009-01-15

    The purpose of this study was to investigate alterations of hepatic arterial flow during transjugular intrahepatic portosystemic stent shunt (TIPS) applying intravascular Doppler sonography. This prospective monocenter study included 25 patients with liver cirrhosis (alcohol induced [n = 19], chronic hepatitis associated [n = 3], primary biliary cirrhosis associated [n = 1], and cryptogenic [n = 2]) successfully treated with TIPS. All patients underwent intravascular hepatic arterial flow measurements during TIPS using an endoluminal flow sensor. The average arterial peak velocity (APV) and the maximum arterial peak velocity (MPV) were registered. Twenty-two patients (88%) showed increased APV, one patient (4%)more » showed unaffected APV, and two patients (8%) showed decreased APV after TIPS. The average portosystemic pressure gradient decreased significantly, from 22.0 {+-} 5.1 mmHg before TIPS to 11.0 {+-} 4.1 mmHg after TIPS (-50.0%; p < 0.0001). The average APV increased significantly, from 41.9 {+-} 17.8 cm/s before TIPS to 60.7 {+-} 19.0 cm/s after TIPS (+44.9%; p < 0.0001). The average MPV increased significantly, from 90.8 {+-} 31.7 cm/s before TIPS to 112.6 {+-} 34.9 cm/s after TIPS (+24.0%; p = 0.0002). These changes in perfusion set in within seconds after TIPS tract formation in all the patients with increased APV. We conclude that TIPS-induced portosystemic decompression leads to a significant increase in hepatic arterial flow. The changes occurred within seconds, suggesting a reflex-like mechanism.« less

  13. Cold-air performance of a 12.766-centimeter-tip-diameter axial-flow cooled turbine. 3: Effect of rotor tip clearance on overall performance of a solid blade configuration

    NASA Technical Reports Server (NTRS)

    Haas, J. E.; Kofskey, M. G.

    1977-01-01

    Two tip clearance configurations, one with a recess in the casing and the other with a reduced rotor blade height, were investigated at design equivalent speed over a range of tip clearance from about 2.0 to 5.0 percent of the stator blade height. The optimum configuration with a recess in the casing was the one where the rotor tip diameter was equal to the stator tip diameter (zero blade extension). For this configuration there was an approximate 1.5 percent decrease in total efficiency for an increase in tip clearance of 1 percent of stator blade height. For the reduced blade height configurations there was an approximate 2.0 percent decrease in total efficiency for an increase in tip clearance of 1 percent of stator blade height.

  14. Disdrometer and Tipping Bucket Rain Gauge Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomew. MJ

    2009-12-01

    The Distromet disdrometer model RD-80 and NovaLynx tipping bucket rain gauge model 260-2500E-12 are two devices deployed a few meters apart to measure the character and amount of liquid precipitation. The main purpose of the disdrometer is to measure drop size distribution, which it does over 20 size classes from 0.3 mm to 5.4 mm. The data from both instruments can be used to determine rain rate. The disdrometer results can also be used to infer several properties including drop number density, radar reflectivity, liquid water content, and energy flux. Two coefficients, N0 and Λ, from an exponential fit betweenmore » drop diameter and drop number density, are routinely calculated. Data are collected once a minute. The instruments make completely different kinds of measurements. Rain that falls on the disdrometer sensor moves a plunger on a vertical axis. The disdrometer transforms the plunger motion into electrical impulses whose strength is proportional to drop diameter. The rain gauge is the conventional tipping bucket type. Each tip collects an amount equivalent to 0.01 in. of water, and each tip is counted by a data acquisition system anchored by a Campbell CR1000 data logger.« less

  15. Electrochemical etching technique of platinum-iridium tips for scanning tunneling microscopy

    NASA Astrophysics Data System (ADS)

    Herrera, Oscar

    The scanning tunneling microscope (STM) allows researchers to investigate atomic and molecular structures and properties of nanomaterials. Through the quantum tunneling effect a charge is transferred between the surface of the material and a Platinum-Iridium (Pt-Ir) tip. The production of Pt-Ir tips by electrochemical etching (ECE) has been developed as an alternative technique, to achieve enhanced scanned images of samples, in contrast to the standard mechanical method (SMM). The sharpness apex structure is an essential feature during scanning in order to provide reliable data. We generated a control group of tips by the SMM technique and another group by the ECE technique to investigate the resolution effectiveness in scanning of graphite. The etching of the tips was produced using an auto-variable transformer running a 30 V AC in a 1.5 and 4.0 M CaCl2 solution. The scanning of the graphite surface was conducted at 7x7 nm image width, 0.2 seconds time/line, 256 points/line and 0.05 V for tip voltage. ECE etched tips displayed consistent image resolution, and the sharpness of the tip apex was generally uniform.

  16. Kinesins have a dual function in organizing microtubules during both tip growth and cytokinesis in Physcomitrella patens.

    PubMed

    Hiwatashi, Yuji; Sato, Yoshikatsu; Doonan, John H

    2014-03-01

    Microtubules (MTs) play a crucial role in the anisotropic deposition of cell wall material, thereby affecting the direction of growth. A wide range of tip-growing cells display highly polarized cell growth, and MTs have been implicated in regulating directionality and expansion. However, the molecular machinery underlying MT dynamics in tip-growing plant cells remains unclear. Here, we show that highly dynamic MT bundles form cyclically in the polarized expansion zone of the moss Physcomitrella patens caulonemal cells through the coalescence of growing MT plus ends. Furthermore, the plant-specific kinesins (KINID1) that are is essential for the proper MT organization at cytokinesis also regulate the turnover of the tip MT bundles as well as the directionality and rate of cell growth. The plus ends of MTs grow toward the expansion zone, and KINID1 is necessary for the stability of a single coherent focus of MTs in the center of the zone, whose formation coincides with the accumulation of KINID1. We propose that KINID-dependent MT bundling is essential for the correct directionality of growth as well as for promoting growth per se. Our findings indicate that two localized cell wall deposition processes, tip growth and cytokinesis, previously believed to be functionally and evolutionarily distinct, share common and plant-specific MT regulatory components.

  17. Sea trials of a ducted tip propeller designed for improved cavitation performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hordnes, I.; Bidaud, A.; Green, S.I.

    1994-12-31

    Studies have shown that ``ring-wing`` or ``ducted`` tip devices reduce substantially the inception index of trailing vortices generated by a hydrofoil (Green et al. 1988). It has also been shown that these devices improve the lift/drag ratio of an airfoil at high angle of incidence (Duan et al. 1992). These finding indicate that there may be a marine application for the ducted tip. Experimental equipment has been designed and manufactured in preparation for upcoming tests of a propeller with ducted tips. The tips are tubes aligned with the propeller blade tips that will replace a radial fraction of the originalmore » blade tips equal to the diameter of the tubes. The tube dimensions have been chosen according to the span/tip diameter and chord/tip length ratios used by Duan et al. (1992), and the tubes will be given a curvature equal to the propeller tip radius. Field trials will be given a curvature equal to the propeller tip radius. Field trials will be conducted on a 36 inch diameter propeller that is used to propel a 45 ft. fishing (seine) boat operating in the coastal waters outside Vancouver. The performance of the propeller will be measured in terms of the propeller efficiency as a function of advance ratio. A special force transducer has been designed that is capable of recording both torque and thrust on the propeller shaft even though these are expected to produce shaft strains of different orders of magnitude. As a supplementary means of monitoring the propeller performance, a hydrophone will be located near the propeller wake in order to measure the tip vortex cavitation noise.« less

  18. Global Projection of Coastal Exposure Associated with Sea-level Rise beyond Tipping Points

    NASA Astrophysics Data System (ADS)

    Tawatari, R.; Miyazaki, C.; Iseri, Y.; Kiguchi, M.; Kanae, S.

    2015-12-01

    Sea-level rise due to global warming becomes a great matter of concern for global coastal area. Additionally, it has reported in fifth report of IPCC (Intergovernmental Panel on Climate Change) that deglaciation of Greenland ice sheet and Antarctic ice sheet would occur rapidly and enhance sea-level rise if temperature passes certain "Tipping point". In terms of projecting damage induced by sea-level rise globally, some previous studies focused on duration until mainly 2100. Furthermore long-term estimations on centuries to millennial climatic response of the ice sheets which are supposed to be triggered within this or next century would be also important to think about future climate and lifestyle in coastal . In this study, I estimated the long term sea-level which take into account the tipping points of Greenland ice sheet (1.4℃) as sum of 4 factors (thermal expansion, glacier and ice cap, Greenland ice sheet, Antarctic ice sheet). The sea-level follows 4 representative concentration pathways up to 3000 obtained through literature reviewing since there were limited available sea-level projections up to 3000. I also estimated a number of affected population lives in coastal area up to 3000 with using the estimated sea-level. The cost for damage, adaptation and mitigation would be also discussed. These estimations would be useful when decision-makers propose policies for construction of dikes and proposing mitigation plans for sustainable future. The result indicates there would be large and relatively rapid increases in both sea-level rise and coastal exposure if global mean temperature passes the tipping point of Greenland ice sheet. However the tipping points, melting rate and timescale of response are highly uncertain and still discussed among experts. Thus more precise and credible information is required for further accurate estimation of long-term sea-level rise and population exposure in the future.

  19. Tip leakage vortex dynamics and inception

    NASA Astrophysics Data System (ADS)

    Oweis, Ghanem; Ceccio, Steven; Jessup, Stuart; Chesnakas, Christopher; Fry, David

    2002-11-01

    The McCormick rule for tip vortex cavitation scaling predicts that cavitation should take place in the vortex where the average core pressure deficit from the free stream is the largest along the vortex tube. The average core pressure deficit can be calculated from the vortex core size and circulation and these can be measured by LDV or hot wire, among other methods. The same rule applies to the tip vortex from a wall-bounded hydrofoil. Recent cavitation inception experiments on a ducted propeller in the NSWCCD 36 inch water tunnel combined with PIV and LDV measurements of the tip vortex flow are described. These tests reveal a disagreement between the actual inception location and that predicted by the McCormick rule. It is hypothesized that in this case the inception mechanism is related to local flow phenomena associated with local vortex unsteadiness, as opposed to the average vortex parameters (core size and circulation) used in the viscous scaling rule of McCormick. Discussion of the flow field measurements, bubble population, and the noise production from the inception events is given.

  20. Influence of wing tip morphology on vortex dynamics of flapping flight

    NASA Astrophysics Data System (ADS)

    Krishna, Swathi; Mulleners, Karen

    2013-11-01

    The mechanism of flapping wing flight provides insects with extraordinary flight capabilities. The uniquely shaped wing tips give insects an edge in flight performance and the interaction between the leading edge vortices and wing tip vortices enhance their propelling efficiencies and manoeuvrability. These are qualities that are sought after in current-day Micro Air Vehicles. A detailed understanding of the vortex dynamics of flapping flight and the influence of the wing tip planform is imperative for technical application. An experimental study is conducted to investigate the effects of different wing tip planforms on the formation, evolution and interaction of vortical structures. We thereby focus on the interaction between the coherent structures evolving from the leading edge and the wing tip during pitching and flapping motions.The spatial and temporal evolution of the three-dimensional flow structures are determined using Scanning (Stereo) Particle Image Velocimetry and an in-depth coherent structure analysis. By comparing the vortex dynamics, the aerodynamic performance of various wing tip planforms are evaluated.

  1. Numerical investigation of tip clearance cavitation in Kaplan runners

    NASA Astrophysics Data System (ADS)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  2. Real life identification of partially occluded weapons in video frames

    NASA Astrophysics Data System (ADS)

    Hempelmann, Christian F.; Arslan, Abdullah N.; Attardo, Salvatore; Blount, Grady P.; Sirakov, Nikolay M.

    2016-05-01

    We empirically test the capacity of an improved system to identify not just images of individual guns, but partially occluded guns and their parts appearing in a videoframe. This approach combines low-level geometrical information gleaned from the visual images and high-level semantic information stored in an ontology enriched with meronymic part-whole relations. The main improvements of the system are handling occlusion, new algorithms, and an emerging meronomy. Well-known and commonly deployed in ontologies, actual meronomies need to be engineered and populated with unique solutions. Here, this includes adjacency of weapon parts and essentiality of parts to the threat of and the diagnosticity for a weapon. In this study video sequences are processed frame by frame. The extraction method separates colors and removes the background. Then image subtraction of the next frame determines moving targets, before morphological closing is applied to the current frame in order to clean up noise and fill gaps. Next, the method calculates for each object the boundary coordinates and uses them to create a finite numerical sequence as a descriptor. Parts identification is done by cyclic sequence alignment and matching against the nodes of the weapons ontology. From the identified parts, the most-likely weapon will be determined by using the weapon ontology.

  3. Characteristics of tip-leakage flow in an axial fan

    NASA Astrophysics Data System (ADS)

    Park, Keuntae; Choi, Haecheon; Choi, Seokho; Sa, Yongcheol

    2014-11-01

    An axial fan with a shroud generates complicated vortical structures by the interaction of the axial flow with the fan blades and shroud near the blade tips. Large eddy simulation (LES) is performed for flow through a forward-swept axial fan, operating at the design condition of Re = 547,000 based on the radius of blade tip and the tip velocity. A dynamic global model (Lee et al. 2010) is used for a subgrid-scale model, and an immersed boundary method in a non-inertial reference frame (Kim & Choi 2006) is adopted for the present simulation. It is found that two vortical structures are formed near the blade tip: the main tip leakage vortex (TLV) and the auxiliary TLV. The main TLV is initiated near the leading edge, develops downstream, and impinges on the pressure surface of the next blade, where the pressure fluctuations and turbulence intensity become high. On the other hand, the auxiliary TLV is initiated at the aft part of the blade but is relatively weak such that it merges with the main TLV. Supported by the KISTI Supercomputing Center (KSC-2014-C2-014).

  4. Writing IS Teaching Tips: Guidelines for "JISE" Submission

    ERIC Educational Resources Information Center

    Lending, Diane; Vician, Chelley

    2012-01-01

    "JISE" has a lengthy history of inviting the submission of Teaching Tips for publication consideration in the journal. Past submission guidance for Teaching Tips has consisted of asking contributors to document the teaching experience and indicate what has worked, and not worked, in its execution within a journal page constraint of one to five…

  5. Using High-Content Imaging to Analyze Toxicological Tipping ...

    EPA Pesticide Factsheets

    Presentation at International Conference on Toxicological Alternatives & Translational Toxicology (ICTATT) held in China and Discussing the possibility of using High Content Imaging to Analyze Toxicological Tipping Points Slide Presentation at International Conference on Toxicological Alternatives & Translational Toxicology (ICTATT) held in China and Discussing the possibility of using High Content Imaging to Analyze Toxicological Tipping Points

  6. Magnetic energy flow imaging of magnetic recording head with enhanced resolution and sensitivity by A-MFM using high magnetic moment superparamagnetic tip

    NASA Astrophysics Data System (ADS)

    Kumar, Pawan; Cao, Yongze; Suzuki, Yudai; Yoshimura, Satoru; Saito, Hitoshi

    2018-06-01

    In this report, the magnetic energy flow of AC magnetic field is imaged from a perpendicular magnetic recording head by alternating magnetic force microscopy (A-MFM) with high magnetic moment Co0.43(GdOx)0.57 superparamagnetic (SP) tip. The present magnetic energy flow imaging phenomenon is able to detect the flow direction of AC magnetic field energy from the recording head. A simple model for the flow direction of the AC magnetic energy is given and revealed that when the AC magnetic field energy from the surface of main pole increases, the energy from the side cross section decreases due to the periodical change of magnetization direction at the main pole area. The A-MFM magnetic energy imaging performance by 100 nm Co0.43(GdOx)0.57 SP tip is compared with the magnetic field imaging with the 25 nm Co0.80Zr0.05Nb0.15 soft magnetic (SM) tip. The spatial resolution measured by Fourier analysis for Co0.43(GdOx)0.57 SP tip is enhanced dramatically to ˜10 nm with low thermal noise, as compared to ˜13 nm by Co0.80Zr0.05Nb0.15 SM tip as well as the previously reported MFM tip. Moreover, the sensitivity and resolution are investigated for a range of head current to confirm the suitability of the magnetic energy flow imaging by Co0.43(GdOx)0.57 SP tip to low as well as high magnetic field source. Further, the A-MFM measurements are performed with the 100 nm Au coated conducting tip to investigate the possibility of electrostatic contribution in magnetic energy imaging by Co0.43(GdOx)0.57 SP tip and revealed that the present A-MFM measurement is free from any electrostatic artifacts. The present magnetic energy flow imaging phenomena with the high magnetic moment Co0.43(GdOx)0.57 SP tip provides an avenue for the analysis of the magnetic field energy component from the head field profile.

  7. Recent trends in television tip over-related injuries among children aged 0-9 years.

    PubMed

    Murray, K J; Griffin, R; Rue, L W; McGwin, G

    2009-08-01

    To describe recent trends in television tip over-related injuries among children aged 0-9 years, and to compare injury rates with sales of newer digital televisions. Digital television sales data were obtained from marketing data provided by the Television Bureau of Advertising. Data regarding television tip over-related injuries among children aged 0-9 years were obtained from the 1998-2007 National Electronic Injury Surveillance System. A Wald chi(2) test, estimated from logistic analysis, was used to determine whether the distribution of injury types differed by age group. Pearson's correlation was used to estimate the association between digital television sales and television tip over-related injuries. An estimated 42 122 (95% CI 35 199 to 49 122) injuries from television tip-overs were treated in US emergency departments from 1998 to 2007. The injury rate was highest for children aged 1-4 years (18.6/100 000). A majority of injuries (63.9%) involved the head and neck for children under 1 year of age, while a higher proportion of injuries among children aged 1-4 involved the hip and lower extremity (42.9% and 31.0%, respectively), and shoulder and upper extremity (16.8%) for children aged 5-9. A strong, positive correlation was observed between television sales and annual injury rates (r = 0.89, p<0.001). Estimates of injury rates were similar to previously reported estimates, particularly for the increased proportion of head and neck injuries among very young children. While digital television sales were strongly correlated with increased injury rates, the lack of information regarding the type of television involved prevents inference regarding causation.

  8. Tip Vortex Cavitation

    NASA Astrophysics Data System (ADS)

    Maines, Brant H.; Arndt, Roger E. A.

    2000-11-01

    Cavitation in vortical flows is a problem of practical importance, that is relatively unexplored. Vortical structures of importance range from the eddies occurring randomly in space and time in turbulent flows to the developed vortices that occur at the tips of lifting surfaces and at the hubs of propellers and hydraulic turbines. A variety of secondary flow phenomena such as the horse shoe vortices that form around bridge piers, chute blocks and struts, and the secondary vortices found in the clearance passages of turbomachinery are also important cavitation sites. Tip vortex cavitation can be viewed as a canonical problem that captures many of the essential physics associated with vortex cavitation in general. This paper describes the inception process and focuses on the high levels of tension that can be sustained in the flow, which appears to scale with the blade loading. High speed video visualization indicates that the details of how free stream nuclei are ingested plays a major role in the nucleation and inception process. A new photographic technique was used to obtain high quality images of the bubble growth process at framing rates as high as 40,000 fps. Sponsored by the Office of Naval Research

  9. Tips to Prevent Tick Bites

    EPA Pesticide Factsheets

    Using the right insect repellent and other preventive actions can discourage ticks, mosquitoes, and other biting insects from landing on you. Tips include avoiding tick habitats and minimizing exposed skin.

  10. Technical tips for collagenase injection treatment for Dupuytren contracture.

    PubMed

    Meals, Roy A; Hentz, Vincent R

    2014-06-01

    We describe technical tips for injecting collagenase into Dupuytren cords based on experience acquired during the prerelease Food and Drug Administration clinical trials and with subsequent clinical practice. These tips include techniques for extracting the reconstituted enzyme efficiently from the vial, injecting the cord(s) with increased safety to the tendons, and anesthetizing the hand before manipulation. The tips are intended to supplement but by no means replace the manufacturer's prescribing information and training video. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Measurement of Rotating Blade Tip Clearance with Fibre-Optic Probe

    NASA Astrophysics Data System (ADS)

    Cao, S. Z.; Duan, F. J.; Zhang, Y. G.

    2006-10-01

    This paper described a tip clearance measuring system with fibre-optic probe. The system is based on a novel tip clearance sensor of optical fibre-bundle mounted on the casing, rotating speed synchronization sensor mounted on the rotating shaft, the tip clearance preamplification processing circuit followed by high speed data-acquisition unit. A novel tip clearance sensor of trifurcated optical fibre bundle was proposed and demonstrated. It is independent of material of measured surface but capacitive probe demands target conductive. Measurements can be taken under severe conditions such as ionization. Sensor circuitry and data acquisition circuit were successfully designed. With the help of Rotation synchronized sensor, all the blades can be detected in real-time. Because of fibre-optic sensor, the measuring system has commendably frequency response, which can work well in high rotating speed from 0-15000rpm.The measurement range of tip clearance is 0-3mm with 25um precision.

  12. Reproducible fabrication and applications of superconducting scanning tunneling microscope tips

    NASA Astrophysics Data System (ADS)

    Naaman, Ofer; Teizer, Winfried; Dynes, Robert C.

    2001-03-01

    We report on a method developed in our lab, for the fabrication of superconducting scanning tunneling microscope (STM) tips in a reproducible fashion. The fabrication process relies on sequential deposition of superconducting Pb and a proximity-coupled Ag capping layer onto a Pt/Ir tip. The tips were characterized by tunneling into both normal-metal and superconducting films, and the results confirm that the tips are superconducting with Tc and Δ close to that of bulk lead. The lead phonon structure in the tunneling density of states was observed, indicating a single step tunneling process. In an attempt to form STM Josephson junctions, we used our tips to form S/I/S junctions with R_NN ~50-100 kΩ. Results from spectroscopic measurements of these junctions at 2.0 K are discussed within the framework of the Ivanchenko and Zil'berman theory (Soviet Physics JETP, vol.28, 1272; 1969) of Josephson tunneling in the presence of strong phase fluctuations.

  13. NMR Model of PrgI-SipD Interaction and its Implications in the Needle-Tip Assembly of the Salmonella Type III Secretion System

    PubMed Central

    Rathinavelan, Thenmalarchelvi; Lara-Tejero, Maria; Lefebre, Matthew; Chatterjee, Srirupa; McShan, Andrew C.; Guo, Da-Chuan; Tang, Chun; Galan, Jorge E.; De Guzman, Roberto N.

    2014-01-01

    Salmonella and other pathogenic bacteria use the type III secretion system (T3SS) to inject virulence proteins into human cells to initiate infections. The structural component of the T3SS contains a needle and a needle tip. The needle is assembled from PrgI needle protomers and the needle tip is capped with several copies of the SipD tip protein. How a tip protein docks on the needle is unclear. A crystal structure of a PrgI-SipD fusion protein docked on the PrgI needle results in steric clash of SipD at the needle tip when modeled on the recent atomic structure of the needle. Thus, there is currently no good model of how SipD is docked on the PrgI needle tip. Previously, we showed by NMR paramagnetic relaxation enhancement (PRE) methods that a specific region in the SipD coiled-coil is the binding site for PrgI. Others have hypothesized that a domain of the tip protein – the N-terminal α-helical hairpin, has to swing away during the assembly of the needle apparatus. Here, we show by PRE methods that a truncated form of SipD lacking the α-helical hairpin domain binds more tightly to PrgI. Further, PRE-based structure calculations revealed multiple PrgI binding sites on the SipD coiled-coil. Our PRE results together with the recent NMR-derived atomic structure of the Salmonella needle suggest a possible model of how SipD might dock at the PrgI needle tip. SipD and PrgI are conserved in other bacterial T3SSs, thus our results have wider implication in understanding other needle-tip complexes. PMID:24951833

  14. Low-coherence interferometric tip-clearance probe

    NASA Astrophysics Data System (ADS)

    Kempe, Andreas; Schlamp, Stefan; Rösgen, Thomas; Haffner, Ken

    2003-08-01

    We propose an all-fiber, self-calibrating, economical probe that is capable of near-real-time, single-port, simultaneous blade-to-blade tip-clearance measurements with submillimeter accuracy (typically <100 μm, absolute) in the first stages of a gas turbine. Our probe relies on the interference between backreflected light from the blade tips during the 1-μs blade passage time and a frequency-shifted reference with variable time delay, making use of a low-coherence light source. A single optical fiber of arbitrary length connects the self-contained optics and electronics to the turbine.

  15. Selectable-Tip Corrosion-Testing Electrochemical Cell

    NASA Technical Reports Server (NTRS)

    Lomness, Janice; Hintze, Paul

    2008-01-01

    The figure depicts aspects of an electrochemical cell for pitting- corrosion tests of material specimens. The cell is designed to generate a region of corrosion having a pit diameter determined by the diameter of a selectable tip. The average depth of corrosion is controlled by controlling the total electric charge passing through the cell in a test. The cell is also designed to produce minimal artifacts associated with crevice corrosion. There are three selectable tips, having diameters of 0.1 in. (0.254 cm), 0.3 in. (0.762 cm), and 0.6 in. (1.524 cm), respectively.

  16. Tip-Based Nanofabrication for Scalable Manufacturing

    DOE PAGES

    Hu, Huan; Kim, Hoe; Somnath, Suhas

    2017-03-16

    Tip-based nanofabrication (TBN) is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. Here in this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  17. Tip-Based Nanofabrication for Scalable Manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Huan; Kim, Hoe; Somnath, Suhas

    Tip-based nanofabrication (TBN) is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. Here in this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  18. Direct mechanical stimulation of tip links in hair cells through DNA tethers

    PubMed Central

    Basu, Aakash; Lagier, Samuel; Vologodskaia, Maria; Fabella, Brian A; Hudspeth, AJ

    2016-01-01

    Mechanoelectrical transduction by hair cells commences with hair-bundle deflection, which is postulated to tense filamentous tip links connected to transduction channels. Because direct mechanical stimulation of tip links has not been experimentally possible, this hypothesis has not been tested. We have engineered DNA tethers that link superparamagnetic beads to tip links and exert mechanical forces on the links when exposed to a magnetic-field gradient. By pulling directly on tip links of the bullfrog's sacculus we have evoked transduction currents from hair cells, confirming the hypothesis that tension in the tip links opens transduction channels. This demonstration of direct mechanical access to tip links additionally lays a foundation for experiments probing the mechanics of individual channels. DOI: http://dx.doi.org/10.7554/eLife.16041.001 PMID:27331611

  19. Transcatheter closure of a small atrial septal defect with an Amplatzer™ patent foramen ovale occluder in a working dog with cyanosis and exercise intolerance at high altitude.

    PubMed

    Shelden, A; Wesselowski, S; Gordon, S G; Saunders, A B

    2017-12-01

    A 6.5-year-old male Border Collie presented for transcatheter closure of an atrial septal defect due to exercise intolerance and cyanosis while working and training at altitude. A small, left-to-right shunting secundum atrial septal defect was confirmed with no evidence of significant right-sided volume overload. Pulmonary hypertension with subsequent right-to-left interatrial shunting occurring during exercise at high altitude was suspected and prompted the closure of the defect due to the dog's continued athletic requirements. The anatomy of the defect prompted use of a patent foramen ovale occluder rather than an atrial septal defect occluder, which was deployed using a combination of fluoroscopic and transesophageal echocardiographic guidance. The owner did not report continued exercise intolerance or cyanosis and the dog's lifestyle and residence at altitude was unchanged. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Flu Prevention and Treatment Tips

    MedlinePlus

    Flu Prevention and Treatment Tips Expert Information from Healthcare Professionals Who Specialize in the Care of Older Adults Influenza, or the “flu,” is a contagious respiratory illness. It can cause ...