Sample records for occlusal contact area

  1. Influence of occlusal contact area on cusp defection and stress distribution.

    PubMed

    Costa, Anna Karina Figueiredo; Xavier, Thaty Aparecida; Paes-Junior, Tarcisio José Arruda; Andreatta-Filho, Oswaldo Daniel; Borges, Alexandre Luiz Souto

    2014-11-01

    The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental

  2. Evaluation of recovery in lip closing pressure and occlusal force and contact area after orthognathic surgery.

    PubMed

    Ueki, Koichiro; Moroi, Akinori; Sotobori, Megumi; Ishihara, Yuri; Marukawa, Kohei; Iguchi, Ran; Kosaka, Akihiko; Ikawa, Hiroumi; Nakazawa, Ryuichi; Higuchi, Masatoshi

    2014-10-01

    The purpose of this study was to evaluate the relationship between lip closing force, occlusal contact area and occlusal force after orthognathic surgery in skeletal Class III patients. The subjects consisted of 54 patients (28 female and 26 male) diagnosed with mandibular prognathism who underwent sagittal split ramus osteotomy with and without Le Fort I osteotomy. Maximum and minimum lip closing forces, occlusal contact area and occlusal force were measured pre-operatively, 6 months and 1 year post-operative. Maximum and minimum lip closing forces, occlusal contact area and occlusal force increased with time after surgery, however a significant increase was not found in the occlusal contact area in women. In increased ratio (6 months/pre-operative and 1 year/pre-operative), the maximum lip closing force was significantly correlated with the occlusal contact area (P < 0.0001). This study suggested that orthognathic surgery could improve the occlusal force, contact area and lip closing force, and an increase ratio in maximum lip closing force was associated with an increased ratio in occlusal contact area. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Geometrical effects of conventional and digital prosthodontic planning wax-ups on lateral occlusal contact number, contact area, and steepness.

    PubMed

    Abduo, Jaafar

    2017-01-01

    This study evaluated and compared the effect of conventional and digital wax-ups on three lateral occlusion variables: contact number, contact area, and steepness. Dental casts of 10 patients with Angle Class I relationship were included in the study. All patients required fixed prosthodontic treatment that would affect lateral occlusion. The casts of all patients received conventional and digital wax-ups. For pretreatment, conventional wax-up, and digital wax-up casts, contact number, contact area, and occlusion steepness were measured at four lateral positions, that is, at excursions of 0.5, 1.0, 2.0, and 3.0 mm from maximal intercuspation. Lateral occlusion scheme variables were affected by use of diagnostic wax-ups. For all types of casts, contact number decreased as excursion increased. The two types of wax-ups had similar contact number patterns, and contact number was significantly greater for these casts than for pretreatment casts in the earlier stages of excursion. Similarly, contact area gradually decreased with increasing excursion in the pretreatment and conventional and digital wax-up casts. There was only a minimal decrease in occlusion steepness as excursion increased. However, lateral occlusion was generally steeper for digital wax-up casts.

  4. Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars.

    PubMed

    Terauchi, Rie; Arai, Korenori; Tanaka, Masahiro; Kawazoe, Takayoshi; Baba, Shunsuke

    2015-01-01

    Implant treatment is believed to cause minimal invasion of remaining teeth. However, few studies have examined teeth adjacent to an implant region. Therefore, this study investigated the effect of occlusal contact size of implants on the periodontal mechanosensitive threshold of adjacent premolars. A cross-sectional study design was adopted. The Department of Oral Implantology, Osaka Dental University, was the setting where patients underwent implant treatment in the mandibular free-end edentulous area. The study population comprised of 87 patients (109 teeth) who underwent follow-up observation for at least 3 years following implant superstructure placement. As variables, age, sex, duration following superstructure placement, presence or absence of dental pulp, occlusal contact area, and periodontal mechanosensitive threshold were considered. The occlusal contact area was measured using Blue Silicone(®)and Bite Eye BE-I(®). Periodontal mechanosensitive threshold were measured using von Frey hair. As quantitative variables for periodontal mechanosensitive threshold, we divided subjects into two groups: normal (≤5 g) and high (≥5.1 g). For statistical analysis, we compared the two groups for the sensation thresholds using the Chi square test for categorical data and the Mann-Whitney U test for continuous volume data. For variables in which a significant difference was noted, we calculated the odds ratio (95 % confidence interval) and the effective dose. There were 93 teeth in the normal group and 16 teeth in the high group based on periodontal mechanosensitive threshold. Comparison of the two groups indicated no significant differences associated with age, sex, duration following superstructure placement, or presence or absence of dental pulp. A significant difference was noted with regard to occlusal contact area, with several high group subjects belonging to the small contact group (odds ratio: 4.75 [1.42-15.87]; effective dose: 0.29). The results of

  5. Occlusal contact of fixed implant prostheses using functional bite impression technique.

    PubMed

    Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2015-02-01

    Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.

  6. Comparing the occlusal contact area of individual teeth during low-level clenching.

    PubMed

    Nishimori, Hideta; Iida, Takashi; Kamiyama, Hirona; Komoda, Yoshihiro; Obara, Ryoko; Uchida, Takashi; Kawara, Misao; Komiyama, Osamu

    2017-09-14

    The aim of this study was to investigate the occlusal contact area (OCA) in individual teeth during low-level tooth clenching in 24 healthy participants. Before measurements were made, the 100% maximum voluntary contraction (MVC) was determined. At baseline, all subjects were instructed to close their mouth and touch the opposing teeth with minimal force. Occlusal contact was recorded during three jaw motor tasks (baseline, 20% MVC, and 40% MVC) using a blue silicone material. OCA thickness was determined from images and defined on five levels: level 1 (0-149 µm), level 2 (0-89 µm), level 3 (0-49 µm), level 4 (0-29 µm), and level 5 (0-4 µm). Premolar and molar OCAs increased significantly from baseline to 20% MVC and 40% MVC. The OCA of each anterior tooth did not change significantly with increasing clenching intensity at all levels. Our findings suggest that premolar and molar OCAs may be altered by low-intensity clenching, affecting the teeth and periodontal tissues.

  7. Comparison of the occlusal contact area of virtual models and actual models: a comparative in vitro study on Class I and Class II malocclusion models.

    PubMed

    Lee, Hyemin; Cha, Jooly; Chun, Youn-Sic; Kim, Minji

    2018-06-19

    The occlusal registration of virtual models taken by intraoral scanners sometimes shows patterns which seem much different from the patients' occlusion. Therefore, this study aims to evaluate the accuracy of virtual occlusion by comparing virtual occlusal contact area with actual occlusal contact area using a plaster model in vitro. Plaster dental models, 24 sets of Class I models and 20 sets of Class II models, were divided into a Molar, Premolar, and Anterior group. The occlusal contact areas calculated by the Prescale method and the virtual occlusion by scanning method were compared, and the ratio of the molar and incisor area were compared in order to find any particular tendencies. There was no significant difference between the Prescale results and the scanner results in both the molar and premolar groups (p = 0.083 and 0.053, respectively). On the other hand, there was a significant difference between the Prescale and the scanner results in the anterior group with the scanner results presenting overestimation of the occlusal contact points (p < 0.05). In Molars group, the regression analysis shows that the two variables express linear correlation and has a linear equation with a slope of 0.917. R 2 is 0.930. Groups of Premolars and Anteriors had a week linear relationship and greater dispersion. Difference between the actual and virtual occlusion revealed in the anterior portion, where overestimation was observed in the virtual model obtained from the scanning method. Nevertheless, molar and premolar areas showed relatively accurate occlusal contact area in the virtual model.

  8. Influence of Articulating Paper Thickness on Occlusal Contacts Registration: A Preliminary Report.

    PubMed

    Brizuela-Velasco, Aritza; Álvarez-Arenal, Ángel; Ellakuria-Echevarria, Joseba; del Río-Highsmith, Jaime; Santamaría-Arrieta, Gorka; Martín-Blanco, Nerea

    2015-01-01

    The objective of this preliminary study was to determine if the occlusal contact surface registered with an articulating paper during fixed prosthodontic treatment was contained within the area marked on a thicker articulating paper. This information would optimize any necessary occlusal adjustment of a prosthesis' veneering material. A convenience sample of 15 patients who were being treated with an implant-supported fixed singleunit dental prosthesis was selected. Occlusal registrations were obtained from each patient using 12-μm, 40-μm, 80-μm, and 200-μm articulating paper. Photographs of the occlusal registrations were obtained, and pixel measurements of the surfaces were taken and overlapped for comparison. The results showed that the thicker the articulating paper, the larger the occlusal contact area obtained. The differences were statistically significant. In all cases, the occlusal registrations obtained with the thinnest articulating paper were contained within the area marked on the thickest articulating paper. The results suggested that the use of thin articulating papers (12-μm or 40-μm) can avoid unnecessary grinding of veneering material or teeth during occlusal adjustment.

  9. Application of photogrammetry for analysis of occlusal contacts.

    PubMed

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. A study on measuring occlusal contact area using silicone impression materials: an application of this method to the bite force measurement system using the pressure-sensitive sheet.

    PubMed

    Ando, Katsuya; Kurosawa, Masahiro; Fuwa, Yuji; Kondo, Takamasa; Goto, Shigemi

    2007-11-01

    The aim of this study was to establish an objective and quantitative method of measuring occlusal contact areas. To this end, bite records were taken with a silicone impression material and a light transmission device was used to read the silicone impression material. To examine the effectiveness of this novel method, the occlusal contact area of the silicone impression material and its thickness limit of readable range were measured. Results of this study suggested that easy and highly accurate measurements of occlusal contact area could be obtained by selecting an optimal applied voltage of the light transmission device and an appropriate color of the silicone impression material.

  11. Two-year follow-up of changes in bite force and occlusal contact area after intraoral vertical ramus osteotomy with and without Le Fort I osteotomy.

    PubMed

    Choi, Y J; Lim, H; Chung, C J; Park, K H; Kim, K H

    2014-06-01

    This study was performed to examine the longitudinal changes in bite force and occlusal contact area after mandibular setback surgery via intraoral vertical ramus osteotomy (IVRO). Patients with mandibular prognathism who underwent IVRO (surgical group: 39 men and 39 women) were compared with subjects with class I skeletal and dental relationships (control group; 32 men and 35 women). The surgical group was divided into two subgroups: 1-jaw surgery (n = 30) and 2-jaw surgery (n = 48). Bite force and contact area were measured in maximum intercuspation with the Dental Prescale System before treatment, within 1 month before surgery, and at 1, 3, 6, 9, 12, and 24 months postsurgery. A linear mixed model was used to investigate the time-dependent changes and associated factors. Bite force and contact area decreased during presurgical orthodontic treatment, were minimal at 1 month postsurgery, and increased gradually thereafter. The 1-jaw and 2-jaw subgroups showed no significant differences in bite force. The time-dependent changes in bite force were significantly different according to the contact area (P < 0.05). The results of this study suggest that bite force and occlusal contact area gradually increase throughout the postsurgical evaluation period. Increasing the occlusal contact area may be essential for improving bite force after surgery. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Accuracy and precision of occlusal contacts of stereolithographic casts mounted by digital interocclusal registrations.

    PubMed

    Krahenbuhl, Jason T; Cho, Seok-Hwan; Irelan, Jon; Bansal, Naveen K

    2016-08-01

    Little peer-reviewed information is available regarding the accuracy and precision of the occlusal contact reproduction of digitally mounted stereolithographic casts. The purpose of this in vitro study was to evaluate the accuracy and precision of occlusal contacts among stereolithographic casts mounted by digital occlusal registrations. Four complete anatomic dentoforms were arbitrarily mounted on a semi-adjustable articulator in maximal intercuspal position and served as the 4 different simulated patients (SP). A total of 60 digital impressions and digital interocclusal registrations were made with a digital intraoral scanner to fabricate 15 sets of mounted stereolithographic (SLA) definitive casts for each dentoform. After receiving a total of 60 SLA casts, polyvinyl siloxane (PVS) interocclusal records were made for each set. The occlusal contacts for each set of SLA casts were measured by recording the amount of light transmitted through the interocclusal records. To evaluate the accuracy between the SP and their respective SLA casts, the areas of actual contact (AC) and near contact (NC) were calculated. For precision analysis, the coefficient of variation (CoV) was used. The data was analyzed with t tests for accuracy and the McKay and Vangel test for precision (α=.05). The accuracy analysis showed a statistically significant difference between the SP and the SLA cast of each dentoform (P<.05). For the AC in all dentoforms, a significant increase was found in the areas of actual contact of SLA casts compared with the contacts present in the SP (P<.05). Conversely, for the NC in all dentoforms, a significant decrease was found in the occlusal contact areas of the SLA casts compared with the contacts in the SP (P<.05). The precision analysis demonstrated the different CoV values between AC (5.8 to 8.8%) and NC (21.4 to 44.6%) of digitally mounted SLA casts, indicating that the overall precision of the SLA cast was low. For the accuracy evaluation

  13. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  14. Evaluation of the occlusal contact of crowns fabricated with the bite impression method.

    PubMed

    Makino, Sachi; Okada, Daizo; Shin, Chiharu; Ogura, Reiko; Ikeda, Masaomi; Miura, Hiroyuki

    2013-09-30

    In prosthodontic treatment, reconstruction of a proper occlusal contact relationship is very important as well as reconstruction of a proper interproximal relationship and marginal fitness. Unfortunately, occlusal relationships are sometimes lost in the process of occlusal adjustment of crowns. The purpose of this study was to compare the occlusal contacts of single crown fabricated by two different types of impression techniques. Nine subjects, whose molars required treatment with crown restoration, were enrolled in this study. Full cast crowns were fabricated using two types of impression techniques: the conventional impression method (CIM) and the bite impression method (BIM). The occlusal contacts of crowns were precisely evaluated at the following stages: after occlusal adjustment on the articulator (Step 0), before occlusal adjustment in the mouth (Step 1), after occlusal adjustment at the intercuspal position (Step 2), and after occlusal adjustment during lateral and protrusive excursions (Step 3). The number of occlusal contacts of the crowns on the functional cusps fabricated with BIM was significantly greater than that with CIM after occlusal adjustment. For this reason, the crowns fabricated with BIM might have a more functionally desirable occlusal surface compared to the crowns fabricated with CIM.

  15. Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis.

    PubMed

    Lima, Ana Paula Barbosa; Vitti, Rafael Pino; Amaral, Marina; Neves, Ana Christina Claro; da Silva Concilio, Lais Regiane

    2018-04-01

    This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values ( P <.05). No statistical differences were found for area of contact points among the groups ( P =.7150). The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

  16. Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.

    PubMed

    Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P

    2008-12-01

    The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p < 0.05). Sufficient vision penalization can be achieved to make occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.

  17. History of materials used for recording static and dynamic occlusal contact marks: a literature review

    PubMed Central

    Rahul, G R.; Poduval, Soorya T.; Shetty, Karunakar; Gupta, Bhawna; Rajora, Varun

    2013-01-01

    In the discipline of prosthetic dentistry it is important not only to examine the occlusion, but to be able to record, store, and transfer the information. Over the years many occlusion testing materials have been used. It has been suggested the clinical recording and transfer of information using waxes and other occlusion recording materials have disadvantages relating to inaccuracy and problems of manipulation. Therefore, there has been introduction of many new systems for recording occlusion contacts to overcome such problems. The correct physiological recovery of occlusion posses as much a challenge as ever for every dentist and technician. Even the smallest high spots measuring just a few microns can cause dysfunctions like temporo-mandibular pain. Occlusal proportions are being constantly changed with every procedure. Therefore, an understanding of the synergy of the teeth in static and dynamic occlusion forms the basis of good dentistry. The purpose of this review article is to give and overview of the various materials and methods that have been used to record occlusal contact marks. Key words:Occlusal contact marks, Occlusion indicators, Occlusion test materials, Occlusion recording materials. PMID:24455051

  18. Accuracy of contacts calculated from 3D images of occlusal surfaces.

    PubMed

    DeLong, R; Knorr, S; Anderson, G C; Hodges, J; Pintado, M R

    2007-06-01

    Compare occlusal contacts calculated from 3D virtual models created from clinical records to contacts identified clinically using shimstock and transillumination. Upper and lower full arch alginate impressions and vinyl polysiloxane centric interocclusal records were made of 12 subjects. Stone casts made from the alginate impressions and the interocclusal records were optically scanned. Three-dimensional virtual models of the dental arches and interocclusal records were constructed using the Virtual Dental Patient Software. Contacts calculated from the virtual interocclusal records and from the aligned upper and lower virtual arch models were compared to those identified clinically using 0.01mm shimstock and transillumination of the interocclusal record. Virtual contacts and transillumination contacts were compared by anatomical region and by contacting tooth pairs to shimstock contacts. Because there is no accepted standard for identifying occlusal contacts, methods were compared in pairs with one labeled "standard" and the second labeled "test". Accuracy was defined as the number of contacts and non-contacts of the "test" that were in agreement with the "standard" divided by the total number of contacts and non-contacts of the "standard". Accuracy of occlusal contacts calculated from virtual interocclusal records and aligned virtual casts compared to transillumination were: 0.87+/-0.05 and 0.84+/-0.06 by region and 0.95+/-0.07 and 0.95+/-0.05 by tooth, respectively. Comparisons with shimstock were: 0.85+/-0.15 (record), 0.84+/-0.14 (casts), and 81+/-17 (transillumination). The virtual record, aligned virtual arches, and transillumination methods of identifying contacts are equivalent, and show better agreement with each other than with the shimstock method.

  19. Relative contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance.

    PubMed

    Lepley, Casey R; Throckmorton, Gaylord S; Ceen, Richard F; Buschang, Peter H

    2011-05-01

    The purpose of this study was to explore the contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance. A prospective cross-sectional study was performed on 30 subjects with Class I occlusion. Masticatory performance was measured with the test food Cuttersil (Heraeus Kulzer, South Bend, Ind) and the fractional-sieve technique. Blu-Mousse (Parkell Biomaterials, Farmingdale, NY) bite registrations were used to measure occlusal contact areas. The American Board of Orthodontics occlusal discrepancies were measured on the subjects' dental models. Maximum bite forces were recorded with a custom transducer, and 3-dimensional chewing cycle kinematics were tracked with an opto-electric computer system and Optotrak software (Northern Digital, Waterloo, Ontario, Canada). Masticatory performance was most closely correlated with occlusal contact area, indicating larger contact areas in subjects with better performance. Occlusal contact area and occlusal discrepancies were also related to bite force and chewing cycle kinematics. Maximum bite force was positively related with masticatory performance. Although masticatory performance is related, both directly and indirectly, to a number of morphologic and functional factors, it is most closely related to occlusal factors. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  20. [Contact dermatitis caused by acetazolamide under occlusion].

    PubMed

    Daveluy, Amélie; Vial, Thierry; Marty, Laurine; Miremont-Salamé, Ghada; Moore, Nicholas; Haramburu, Françoise

    2007-12-01

    Acetazolamide is a carbonic anhydrase inhibitor used topically for local secondary treatment of posttraumatic or postoperative edema. Two women had contact dermatitis, secondarily extensive, after local cutaneous use of acetazolamide under a compression panty after liposuction. The eruption disappeared after acetazolamide was stopped and local treatment administered. Cutaneous tests were positive for acetazolamide. Local allergic reactions are mentioned in the monograph on topical acetazolamide. Cases of contact dermatitis from this drug have not so far been published, but French adverse drug reaction reporting data include 10 other cases of eczema or rash at the application site. In one of these, a positive reaction was observed on readministration, and in 2 cases allergy skin tests were positive. The application of the drug under occlusion, which is contraindicated, may have contributed to spreading the lesions. Cases have also been described with another carbonic anhydrase inhibitor, dorzolamide, used in ophthalmology.

  1. A possible association of idiopathic osteosclerosis with excessive occlusal forces.

    PubMed

    Misirlioglu, Melda; Nalcaci, Rana; Baran, Ilgi; Adisen, Mehmet Zahit; Yilmaz, Selmi

    2014-03-01

    The aim of the study was to determine the relationship between idiopathic osteosclerotic lesions and occlusal forces using the T-Scan II computerized occlusal analysis device, and to test the sensitivity of the system in occlusal analysis. The study was conducted with 21 volunteers with idiopathic osteosclerosis (IO; 14 women, 7 men) aged between 17 and 62 years (mean 29.95). For every patient, seven or eight recordings were made with the T-Scan II occlusal analysis device in maximum intercuspation, and the last two (excluding any with technical problems) were chosen for evaluation. For each lesion-related area, the distribution of high occlusal forces from two different movies was analyzed. In 18 patients (85.71%), lesions were observed in an area of high occlusal force, and in 13 patients (61.9%), the lesions were located at the first area subjected to high occlusal forces. The percentage distribution of high forces at a lesion related area ranged from 0% to 88%. On average, the high forces at an osteosclerotic lesion area accounted for 20% of the maximum total force. No statistical differences were observed between the measurements of the two selected recordings (P > .05). The findings of this study suggest a possible relationship between IO and occlusal forces and primary contacts. T-Scan II was found to be a successful diagnostic device for detecting primary contacts and excessive occlusal forces.

  2. Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review.

    PubMed

    Borrego, Leopoldo; Hernández, Noelia; Hernández, Zaida; Peñate, Yeray

    2016-05-01

    Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. © 2015 The International Society of Dermatology.

  3. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

    PubMed

    Kim, Yongsik; Oh, Tae-Ju; Misch, Carl E; Wang, Hom-Lay

    2005-02-01

    Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

  4. Using occlusal wear information and finite element analysis to investigate stress distributions in human molars

    PubMed Central

    Benazzi, Stefano; Kullmer, Ottmar; Grosse, Ian R; Weber, Gerhard W

    2011-01-01

    Simulations based on finite element analysis (FEA) have attracted increasing interest in dentistry and dental anthropology for evaluating the stress and strain distribution in teeth under occlusal loading conditions. Nonetheless, FEA is usually applied without considering changes in contacts between antagonistic teeth during the occlusal power stroke. In this contribution we show how occlusal information can be used to investigate the stress distribution with 3D FEA in lower first molars (M1). The antagonistic crowns M1 and P2–M1 of two dried modern human skulls were scanned by μCT in maximum intercuspation (centric occlusion) contact. A virtual analysis of the occlusal power stroke between M1 and P2–M1 was carried out in the Occlusal Fingerprint Analyser (OFA) software, and the occlusal trajectory path was recorded, while contact areas per time-step were visualized and quantified. Stress distribution of the M1 in selected occlusal stages were analyzed in strand7, considering occlusal information taken from OFA results for individual loading direction and loading area. Our FEA results show that the stress pattern changes considerably during the power stroke, suggesting that wear facets have a crucial influence on the distribution of stress on the whole tooth. Grooves and fissures on the occlusal surface are seen as critical locations, as tensile stresses are concentrated at these features. Properly accounting for the power stroke kinematics of occluding teeth results in quite different results (less tensile stresses in the crown) than usual loading scenarios based on parallel forces to the long axis of the tooth. This leads to the conclusion that functional studies considering kinematics of teeth are important to understand biomechanics and interpret morphological adaptation of teeth. PMID:21615398

  5. Measuring contact area in a sliding human finger-pad contact.

    PubMed

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Thickness and marking quality of different occlusal contact registration strips

    PubMed Central

    TOLEDO, Maria Fernanda de Souza Mauá Serapião; JÓIAS, Renata Pilli; MARQUES-IASI, Yves Santini; NEVES, Ana Christina Claro; RODE, Sigmar de Mello

    2014-01-01

    Objectives Evaluate the thickness and the marking quality of different occlusal contact registration strips (OCRS) and a possible correlation between them. Material and Methods The following OCRS were selected: Accufilm II, BK20, BK21, BK22, BK23, BK28, and BK31. The thickness was measured in three points of the OCRS with an electronic measuring device (TESA), and the mean was calculated. To produce the marks on the strips, composite resin specimens were adapted to a universal testing machine (Versat 2000) with 40 kgf load cell at a speed of 1.0 mm/min. The mark images were photographed with a stereoscopic microscope (Stemi SV11) and processed and analyzed by the 550-Leica Qwin® analyzer. Results Values (μm) found in the 1st and 2nd thickness measurements were: Accufilm II - 16.4 and 14.2; BK20 - 10.0 and 8.1; BK21 - 9.5 and 8.0; BK22 - 9.7 and 8.7; BK23 - 9.8 and 7.9; BK28 - 12.8 and 10.0; and BK31 - 8.4 and 8.0, respectively. The mean (mm2) values found in the mark areas were: Accufilm II - 0.078; BK20 - 0.035; BK21 - 0.045; BK22 - 0.012; BK23 - 0.022; BK28 - 0.024; and BK31 - 0.024. The results were submitted to the Kruskal-Wallis (p<0.05) and Pearson’s correlation tests. Conclusions Only in the 2nd measurement, the OCRS thickness observed was similar to the value indicated by the manufacturers; the Accufilm II and the BK28 strips showed the better marks; and no correlation was found between the thickness and the marking area. PMID:25591020

  7. Assessment of electromyographic activity in patients with temporomandibular disorders and natural mediotrusive occlusal contact during chewing and tooth grinding.

    PubMed

    Fuentes, Aler D; Sforza, Chiarella; Miralles, Rodolfo; Ferreira, Cláudia L; Mapelli, Andrea; Lodetti, Gianluigi; Martin, Conchita

    2017-05-01

    The aim of this study was to investigate whether the presence of a natural mediotrusive contact influences electromyographic (EMG) pattern activity in patients with temporomandibular disorders (TMDs). Bilateral surface EMG activity of the anterior temporalis (AT), masseter (MM), and sternocleidomastoid (SCM) muscles was recorded in 43 subjects during unilateral chewing and tooth grinding. Thirteen patients had TMD and a natural mediotrusive contact (Group 1), 15 had TMD without a natural mediotrusive contact (Group 2), and 15 were healthy subjects without mediotrusive contacts (Group 3). All subjects were examined according to the Research Diagnostic Criteria for TMD (RDC/TMD). All EMG values were standardized as the percentage of EMG activity recorded during maximum isometric contraction on cotton rolls. EMG activity from all muscles measured showed no significant differences between groups during chewing and grinding. Overall, in all groups, the EMG activity during chewing was higher in the working side than the non-working side in AT and MM muscles. During grinding, these differences were only found in masseter muscles (mainly in eccentric grinding). SCM EMG activity did not show significant differences during chewing and grinding tasks. Symmetry, muscular balance, and absence of lateral jaw displacement were common findings in all groups. EMG results suggest that the contribution of a natural mediotrusive occlusal contact to EMG patterns in TMD patients is minor. Therefore, the elimination of this occlusal feature for therapeutic purposes could be not indicated.

  8. Inheritance of Occlusal Topography: A Twin Study

    PubMed Central

    Su, C-Y.; Corby, P.M.; Elliot, M.A.; Studen-Pavlovich, D.A.; Ranalli, D.N.; Rosa, B.; Wessel, J.; Schork, N.J.; Hart, T.C.; Bretz, W.A.

    2011-01-01

    Aim This was to determine the relative contribution of genetic factors on the morphology of occlusal surfaces of mandibular primary first molars by employing the twin study model. Methods The occlusal morphology of mandibular primary first molar teeth from dental casts of 9 monozygotic (MZ) twin pairs and 12 dizygotic (DZ) twin pairs 4 to 7 years old, were digitized by contact-type three-dimensional (3D) scanner. To compare the similarity of occlusal morphology between twin sets, each twin pair of occlusal surfaces was superimposed to establish the best fit by using computerized least squared techniques. Heritability was computed using a variance component model, adjusted for age and gender. Results DZ pairs demonstrated a greater degree of occlusal morphology variance. The total amount of difference in surface overlap was 0.0508 mm (0.0018 (inches) for the MZ (n=18) sample and 0.095 mm (0.0034 inches) for the DZ (n=24) sample and were not statistically significant (p=0.2203). The transformed mean differences were not statistically significantly different (p=0.2203). Heritability estimates of occlusal surface areas for right and left mandibular primary first molars were 97.5% and 98.2% (p<0.0001), respectively. Conclusions Occlusal morphology of DZ twin pairs was more variable than that of MZ twin pairs. Heritability estimates revealed that genetic factors strongly influence occlusal morphology of mandibular primary first molars. PMID:18328234

  9. Solar Cels With Reduced Contact Areas

    NASA Technical Reports Server (NTRS)

    Daud, T.; Crotty, G. T.; Kachare, A. H.; Lewis, J. T.

    1987-01-01

    Efficiency of silicon solar cells increased about 20 percent using smaller metal-contact area on silicon at front and back of each cell. Reduction in contact area reduces surface recombination velocity under contact and thus reduces reverse saturation current and increases opencircuit voltage..

  10. [Determination of joint contact area using MRI].

    PubMed

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  11. Evaluation of the electrical contact area in contact-mode scanning probe microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Celano, Umberto, E-mail: celano@imec.be, E-mail: u.celano@gmail.com; Chintala, Ravi Chandra; Vandervorst, Wilfried

    The tunneling current through an atomic force microscopy (AFM) tip is used to evaluate the effective electrical contact area, which exists between tip and sample in contact-AFM electrical measurements. A simple procedure for the evaluation of the effective electrical contact area is described using conductive atomic force microscopy (C-AFM) in combination with a thin dielectric. We characterize the electrical contact area for coated metal and doped-diamond tips operated at low force (<200 nN) in contact mode. In both cases, we observe that only a small fraction (<10 nm{sup 2}) of the physical contact (∼100 nm{sup 2}) is effectively contributing to the transportmore » phenomena. Assuming this reduced area is confined to the central area of the physical contact, these results explain the sub-10 nm electrical resolution observed in C-AFM measurements.« less

  12. Friction and universal contact area law for randomly rough viscoelastic contacts.

    PubMed

    Scaraggi, M; Persson, B N J

    2015-03-18

    We present accurate numerical results for the friction force and the contact area for a viscoelastic solid (rubber) in sliding contact with hard, randomly rough substrates. The rough surfaces are self-affine fractal with roughness over several decades in length scales. We calculate the contribution to the friction from the pulsating deformations induced by the substrate asperities. We also calculate how the area of real contact, A(v, p), depends on the sliding speed v and on the nominal contact pressure p, and we show how the contact area for any sliding speed can be obtained from a universal master curve A(p). The numerical results are found to be in good agreement with the predictions of an analytical contact mechanics theory.

  13. Optimization of the static occlusion by "occlusal surface settling" in the Cerec 3D software.

    PubMed

    Späth, C; Kordass, B

    2006-04-01

    The adjustment of the static occlusion can be automated in computer-based systems. The Cerec 3D software makes it possible to take preformed occlusal surfaces from a database and adapt them to the antagonist. In this adaptation (settling), the CAD occlusal surface "settles" as whole or each cusp individually into the occlusal surface of the antagonist until stable occlusion is reached. Two occlusal surface shapes were compared: Vita Physiodens and Lee Culp. An index was formed from the number, quality, and position of the occlusal contacts for 35 model cases (25 molars, 10 premolars). With regard to the settling of the total occlusal surfaces, there were no differences between the two occlusal surface shapes. In "cusp settling" of the molars, Vita Physiodens performed significantly better. In the comparison of the 1st with the 3rd settling process, significant improvements occurred the 3rd time in many cases when settling individual cusps, but in clearly fewer cases in the settling process of the total occlusal surface. The Lee Culp tooth occlusion improved especially after the 3rd settling process of individual cusps. It is therefore expedient to combine both settling versions with one another.

  14. Influence of denture adhesives on occlusion and disocclusion times.

    PubMed

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Contact Aspiration Versus Stent Retriever in Patients With Acute Ischemic Stroke With M2 Occlusion in the ASTER Randomized Trial (Contact Aspiration Versus Stent Retriever for Successful Revascularization).

    PubMed

    Gory, Benjamin; Lapergue, Bertrand; Blanc, Raphael; Labreuche, Julien; Ben Machaa, Malek; Duhamel, Alain; Marnat, Gautier; Saleme, Suzana; Costalat, Vincent; Bracard, Serge; Desal, Hubert; Mazighi, Mikael; Consoli, Arturo; Piotin, Michel

    2018-02-01

    Middle cerebral artery M2-segment occlusions represent an important subgroup of patients with acute stroke with large-vessel occlusion. The safety of mechanical thrombectomy, especially contact aspiration (CA), in such distal intracranial occlusions is still under debate. We compared reperfusion, adverse events, neurological recovery, and functional outcome of patients with isolated M2 occlusions according to the first-line strategy mechanical thrombectomy devices (CA versus stent retriever [SR]). This is a post hoc analysis of the ASTER trial (Contact Aspiration Versus Stent Retriever for Successful Revascularization). The primary outcome was successful reperfusion at the end of all endovascular procedures, defined as modified Thrombolysis in Cerebral Infarction (mTICI) scores 2b/3. Secondary outcomes were mTICI 2c/3 and mTICI 3, 90-day functional outcome, assessed with the modified Rankin Scale score. Safety outcomes included 90-day mortality and any symptomatic intracerebral hemorrhage. Seventy-nine patients were included: 48 were allocated to the CA group and 31 to the SR group. There were no significant differences between CA and SR groups in reperfusion after all endovascular procedures regarding mTICI 2b/3 (89.6% versus 83.9%; P =0.36), mTICI 2c/3 (54.2% versus 54.8%; P =0.90), and mTICI 3 (35.4% versus 41.9%; P =0.36) rates. There were no significant differences between CA and SR groups in 90-day modified Rankin Scale ≤2 rate (54.4% versus 50.0%; P =0.84), 24-hour change in National Institutes of Health Stroke Scale (mean difference, -3.9; 95% confidence interval, -7.9 to 0.01), and Alberta Stroke Program Early Computed Tomography score (mean difference, 0.9; 95% confidence interval, -0.1 to 2.0) scores. Safety parameters were well balanced between the 2 groups except for a higher 90-day mortality rate in the CA group (19.6% versus 3.3%; P =0.078). First-line mechanical thrombectomy with CA compared with SR did not result in an increased successful

  16. Effect of occlusal interference on habitual activity of human masseter.

    PubMed

    Michelotti, A; Farella, M; Gallo, L M; Veltri, A; Palla, S; Martina, R

    2005-07-01

    It has been suggested that occlusal interference may increase habitual activity in the jaw muscles and may lead to temporomandibular disorders (TMD). We tested these hypotheses by means of a double-blind randomized crossover experiment carried out on 11 young healthy females. Strips of gold foil were glued either on a selected occlusal contact area (active interference) or on the vestibular surface of the same tooth (dummy interference) and left for 8 days each. Electromyographic masseter activity was recorded in the natural environment by portable recorders under interference-free, dummy-interference, and active-interference conditions. The active occlusal interference caused a significant reduction in the number of activity periods per hour and in their mean amplitude. The EMG activity did not change significantly during the dummy-interference condition. None of the subjects developed signs and/or symptoms of TMD throughout the whole study, and most of them adapted fairly well to the occlusal disturbance.

  17. Occlusal accommodation and mouthguards for prevention of orofacial trauma.

    PubMed

    Geary, Julian Lindsay; Clifford, Thomas Joseph; Kinirons, Martin James

    2009-01-01

    The aim of this study was to investigate the effect of two types of occlusal accommodation on the arch separation in centric and eccentric arch positions and to assess the opposing tooth contacts in professionally made, thermoformed sports mouthguards. Maxillary and mandibular alginate impressions, a wax interocclusal record of centric occlusion together with maxillary/condylar face-bow registrations, were recorded clinically for 10 undergraduate dental students who are sports activist volunteers of the School of Medicine and Dentistry, Queen's University Belfast. Two ethylene vinyl acetate thermoformed maxillary mouthguards were made for each player (N = 20) using a standardised procedure. Ten mouthguards served both as the control (i.e. the non-accommodated) group and also the accommodated, occlusally 'imprinted' group. The other 10 mouthguards served as the accommodated, occlusally 'ground' group. Casts were articulated, each non-accommodated and accommodated mouthguard was seated and the extent of the interocclusal opening was recorded in all three arch relationships. The number of mouthguard and mandibular tooth contacts were also recorded in each position. The increased vertical occlusal dimension that was found in the presence of non-accommodated mouthguards equated to the full-sheet thickness of the material that was used to form the mouthguards. Only mouthguards accommodated by grinding retained high levels of occlusal contact in all arch relationships that were tested. Within the limitations of this study, the modification of the occlusal surface made by flat grinding reduced the arch separation in eccentric movements and increased the opposing tooth contacts in custom-made mouthguards. This may contribute to increased comfort, compliance and the protective effect of these appliances thus resulting in a reduction of injuries to the teeth, arches and soft tissues.

  18. Differences in finger skin contact cooling response between an arterial occlusion and a vasodilated condition.

    PubMed

    Jay, Ollie; Havenith, George

    2006-05-01

    To assess the presence and magnitude of the effect of skin blood flow on finger skin cooling on contact with cold objects against the background of circulatory disorder risks in occupational exposures, this study investigates the effect of zero vs. close-to-maximal hand blood flow on short-term (< or =180 s) skin contact cooling response at a contact pressure that allows capillary perfusion of the distal pulp of the fingertip. Six male volunteers touched a block of aluminium with a finger contact force of 0.5 N at a temperature of -2 degrees C under a vasodilated and an occluded condition. Before both conditions, participants were required to exercise in a hot room for > or = 30 min for cutaneous vasodilation to occur (increase in rectal temperature of 1 degrees C). Under the vasodilated condition, forearm blood flow rate rose as high as 16.8 ml.100 ml(-1).min(-1). Under the occluded condition, the arm was exsanguinated, after which a blood pressure cuff was secured on the wrist inducing arterial occlusion. Contact temperature of the finger pad during the subsequent cold contact exposure was measured. No significant difference was found between the starting skin temperatures for the two blood flow conditions, but a distinct difference in shape of the contact cooling curve was apparent between the two blood flow conditions, with Newtonian cooling observed under the occluded condition, whereas a rewarming of the finger skin toward the end of the exposure occurred for the vasodilated condition. Blood flow was found to significantly increase contact temperature from 40 s onward (P < 0.01). It is concluded that, at a finger contact force compatible with capillary perfusion of the finger pad ( approximately 0.5 N), circulating blood provides a heat input source that significantly affects finger skin contact cooling during a vasodilated state.

  19. In vivo THz imaging of human skin: Accounting for occlusion effects.

    PubMed

    Sun, Qiushuo; Parrott, Edward P J; He, Yuezhi; Pickwell-MacPherson, Emma

    2018-02-01

    In vivo terahertz (THz) imaging of human skin needs to be done in reflection geometry due to the high attenuation of THz light by water in the skin. To aid the measurement procedure, there is typically an imaging window onto which the patient places the area of interest. The window enables better pulse alignment and helps keep the patient correctly positioned during the measurement. In this paper, we demonstrate how the occlusion caused by the skin contact with the imaging window during the measurement affects the THz response. By studying both rapid point measurements and imaging over an area of a human volar forearm, we find that even 5 seconds of occlusion affects the THz response. As the occlusion time increases, the skin surface water content increases, resulting in the reduction of the amplitude of the reflected THz pulse, especially in the first 3 minutes. Furthermore, it was found that the refractive index of the volar forearm increased by 10% to 15% after 20 minutes of occlusion. In this work, we examine and propose a model for the occlusion effects due to the quartz window with a view to compensating for its influence. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Biomechanics of occlusion--implications for oral rehabilitation.

    PubMed

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. © 2015 John Wiley & Sons Ltd.

  1. Occlusion of artificial teeth in partial dentures in the "chewing center"--first exploratory population-based evaluations.

    PubMed

    Kordass, B; Ruge, S; Quooss, A; Hugger, A; Mundt, T

    2014-01-01

    Occlusal performance is a substantial determinant of the quality of dental prosthetic restorations. In the follow-up (SHIP 1) to the Study of Health in Pomerania (SHIP), a representative population of 3300 subjects was studied in the first exploratory evaluation of the occlusion of artificial teeth in the chewing center (first molar region) of partial dentures. A digital analysis of interocclusal records of habitual intercuspation position (ICP) was performed using the Greifswald Digital Analyzing System (GEDAS), a software package that identifies contact points as transparent areas. 562 subjects (280 men aged 61.7 ± 11.9 years and 282 women aged 60.7 ± 10.7 years) had maxillary removable partial dentures (RPDs), and 619 (271 men aged 65.0 ± 11.5 years and 348 women aged 62.4 ± 10.6 years) had mandibular RPDs. Most RPDs were retained with either attachment retainers (11.7% maxilla, 11.7% mandible), cast clasps (38.4% maxilla, 40.7% mandible), telescopes with double crowns (15.7% maxilla, 19.1% mandible), or wrought wire clasps (16.4% maxilla, 8.2% mandible). Some had a combination of different retention elements. The mean number of artificial teeth was 7.8 ± 2.9 in the maxilla and 7.5 ± 3.0 in the mandible. Only the artificial teeth (first molars) in mandibular partial dentures showed differences in the frequency of occlusal contacts between groups (chi-square test). Of these, telescopic crown-retained RPDs had the highest frequency of occlusal contacts (74.4% at tooth 36 and 77.1% at tooth 46), and wrought wire-retained RPDs had the lowest (48.4% at tooth 36 and 45.2% at tooth 46). The results for RPDs with a free-end saddle were comparable and analogous; contact frequencies for those with an interdental saddle did not differ significantly. Notably, the overall frequency of occlusal contacts was greater for tooth 46 (62.9%) than for tooth 36. In conclusion, when replacing teeth in the chewing center, particularly in the mandible, telescopic crown

  2. Haptic simulation framework for determining virtual dental occlusion.

    PubMed

    Wu, Wen; Chen, Hui; Cen, Yuhai; Hong, Yang; Khambay, Balvinder; Heng, Pheng Ann

    2017-04-01

    The surgical treatment of many dentofacial deformities is often complex due to its three-dimensional nature. To determine the dental occlusion in the most stable position is essential for the success of the treatment. Computer-aided virtual planning on individualized patient-specific 3D model can help formulate the surgical plan and predict the surgical change. However, in current computer-aided planning systems, it is not possible to determine the dental occlusion of the digital models in the intuitive way during virtual surgical planning because of absence of haptic feedback. In this paper, a physically based haptic simulation framework is proposed, which can provide surgeons with the intuitive haptic feedback to determine the dental occlusion of the digital models in their most stable position. To provide the physically realistic force feedback when the dental models contact each other during the searching process, the contact model is proposed to describe the dynamic and collision properties of the dental models during the alignment. The simulated impulse/contact-based forces are integrated into the unified simulation framework. A validation study has been conducted on fifteen sets of virtual dental models chosen at random and covering a wide range of the dental relationships found clinically. The dental occlusions obtained by an expert were employed as a benchmark to compare the virtual occlusion results. The mean translational and angular deviations of the virtual occlusion results from the benchmark were small. The experimental results show the validity of our method. The simulated forces can provide valuable insights to determine the virtual dental occlusion. The findings of this work and the validation of proposed concept lead the way for full virtual surgical planning on patient-specific virtual models allowing fully customized treatment plans for the surgical correction of dentofacial deformities.

  3. Combining technologies: a computerized occlusal analysis system synchronized with a computerized electromyography system.

    PubMed

    Kerstein, Robert B

    2004-04-01

    Current advances in computer technologies have afforded dentists precision ways to examine occlusal contacts and muscle function. Recently, two separate computer technologies have been synchronized together, so that an operator can record their separate diagnostic data simultaneously. The two systems are: the T Scan II Occlusal Analysis System and the Biopak Electromyography Recording System. The simultaneous recording and playback capacity of these two computer systems allows the operator to analyze and correlate specific occlusal moments to specific electromyographic changes that result from these occlusal moments. This synchronization provides unparalleled evidence of the effect occlusal contact arrangement has on muscle function. Therefore, the occlusal condition of an inserted dental prosthesis or the occlusal scheme of the natural teeth (before and after corrective occlusal adjustments) can be readily evaluated, documented, and quantified for both, quality of occlusal parameters and muscle activity and the responses to the quality of the occlusal condition. This article describes their synchronization and illustrates their use in performing precision occlusal adjustment procedures on two patients: one who demonstrates occlusal disharmony while exhibiting the signs and symptoms of chronic myofascial pain dysfunction syndrome, and the other who had extensive restorative work accomplished but exhibits occlusal discomfort post-operatively.

  4. Reducing contact resistance in graphene devices through contact area patterning.

    PubMed

    Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D

    2013-04-23

    Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.

  5. Effect of time derivative of contact area on dynamic friction

    NASA Astrophysics Data System (ADS)

    Arakawa, Kazuo

    2014-06-01

    This study investigated dynamic friction during oblique impact of a golf ball by evaluating the ball's angular velocity, contact force, and the contact area between the ball and target. The effect of the contact area on the angular velocities was evaluated, and the results indicated that the contact area plays an important role in dynamic friction. In this study, the dynamic friction force F was given by F = μN + μη dA/dt, where μ is the coefficient of friction, N is the contact force, dA/dt is the time derivative of the contact area A, and η is a coefficient associated with the contact area.

  6. Deformation processes within wheel-rail adhesion in contact area

    NASA Astrophysics Data System (ADS)

    Albagachiev, A. Yu; Keropyan, A. M.

    2018-03-01

    The study of working surface deformation during interaction of open-pit locomotive tires allowed defining outstanding features of phenomena occurring in the contact area of interacting surfaces. It was found that processes typical for plastic saturated contact occur in the area of wheel-rail interaction of industrial railway transport. In case of plastic deformation exposed to heavy loads typical for open-pit locomotives, upon all rough surfaces of the contour contact area being fully deformed, the frame on which they are found is exposed to plastic deformation. Plastic deformation of roughness within the contact area of interacting surfaces leads to the increase in the actual area of their contact and, therefore, increases the towing capacity of mining machines. Finally, the available data on deformation characteristics with regard to processes occurring in the contact area of wheel-rail interaction will allow making theoretical forecasts on the expected design value of friction coefficient and, therefore, the towing capacity of open-pit locomotives.

  7. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    PubMed

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  8. An experimental analysis of the real contact area between an electrical contact and a glass plane

    NASA Astrophysics Data System (ADS)

    Down, Michael; Jiang, Liudi; McBride, John W.

    2013-06-01

    The exact contact between two rough surfaces is usually estimated using statistical mathematics and surface analysis before and after contact has occurred. To date the majority of real contact and loaded surfaces has been theoretical or by numerical analyses. A method of analysing real contact area under various loads, by utilizing a con-contact laser surface profiler, allows direct measurement of contact area and deformation in terms of contact force and plane displacement between two surfaces. A laser performs a scan through a transparent flat side supported in a fixed position above the base. A test contact, mounted atop a spring and force sensor, and a screw support which moves into contact with the transparent surface. This paper presents the analysis of real contact area of various surfaces under various loads. The surfaces analysed are a pair of Au coated hemispherical contacts, one is a used Au to Au coated multi-walled carbon nanotubes surface, from a MEMS relay application, the other a new contact surface of the same configuration.

  9. Determination of the nano-scaled contact area of staphylococcal cells.

    PubMed

    Spengler, Christian; Thewes, Nicolas; Jung, Philipp; Bischoff, Markus; Jacobs, Karin

    2017-07-20

    Bacterial adhesion is a crucial step during the development of infections as well as the formation of biofilms. Hence, fundamental research of bacterial adhesion mechanisms is of utmost importance. So far, less is known about the size of the contact area between bacterial cells and a surface. This gap will be filled by this study using a single-cell force spectroscopy-based method to investigate the contact area between a single bacterial cell of Staphylococcus aureus and a solid substrate. The technique relies on the strong influence of the hydrophobic interaction on bacterial adhesion: by incrementally crossing a very sharp hydrophobic/hydrophilic interface while performing force-distance curves with a single bacterial probe, the bacterial contact area can be determined. Assuming circular contact areas, their radii - determined in our experiments - are in the range from tens of nanometers to a few hundred nanometers. The contact area can be slightly enlarged by a larger load force, yet does not resemble a Hertzian contact, rather, the enlargement is a property of the individual bacterial cell. Additionally, Staphylococcus carnosus has been probed, which is less adherent than S. aureus, yet both bacteria exhibit a similar contact area size. This corroborates the notion that the adhesive strength of bacteria is not a matter of contact area, but rather a matter of which and how many molecules of the bacterial species' cell wall form the contact. Moreover, our method of determining the contact area can be applied to other microorganisms and the results might also be useful for studies using nanoparticles covered with soft, macromolecular coatings.

  10. Changes of bite force and occlusal contacts in the retention phase of orthodontic treatment: A controlled clinical trial.

    PubMed

    Varga, Suzana; Spalj, Stjepan; Anic Milosevic, Sandra; Lapter Varga, Marina; Mestrovic, Senka; Trinajstic Zrinski, Magda; Slaj, Mladen

    2017-12-01

    We aimed to determine whether appliance type affects changes in maximum voluntary bite force (MVBF) and the number of occlusal contacts (NOC) during retention, controlling for sex, age, and body mass index. The sample comprised 176 examinees (70 male, 106 female) aged 14 to 20 years: 30 had maxillary and mandibular Essix retainers, 30 had wrap-around retainers, and 30 had a combination of fixed mandibular canine-to-canine retainers bonded on each tooth separately (double twisted, 0.254 mm in diameter, stainless steel ligature wire) and Essix retainer in the maxillary arch; 86 with normal occlusion were not treated. MVBF and the NOC were measured immediately after removal of preadjusted edgewise appliances (Roth prescription), 6 weeks after that, and after the next 4 weeks. Increases in MVBF and the NOC were demonstrated, but subjects with 2 Essix retainers showed lower values than did the others. Changes were related to type of appliance, sex, and age (P <0.05) but not to body mass index. The increase in NOC occurred faster than the increase of MVBF, more and sooner with the wrap-around retainer and in male subjects than with the Essix and in female subjects. MVBF and NOC nearly reached the values of the control subjects. Settling of the occlusion depends on appliance type: it takes longer in female patients and with Essix in both dental arches than with the other tested appliances. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. Visual Acuity Is Correlated with the Area of the Foveal Avascular Zone in Diabetic Retinopathy and Retinal Vein Occlusion.

    PubMed

    Balaratnasingam, Chandrakumar; Inoue, Maiko; Ahn, Seungjun; McCann, Jesse; Dhrami-Gavazi, Elona; Yannuzzi, Lawrence A; Freund, K Bailey

    2016-11-01

    To determine if the area of the foveal avascular zone (FAZ) is correlated with visual acuity (VA) in diabetic retinopathy (DR) and retinal vein occlusion (RVO). Cross-sectional study. Ninety-five eyes of 66 subjects with DR (65 eyes), branch retinal vein occlusion (19 eyes), and central retinal vein occlusion (11 eyes). Structural optical coherence tomography (OCT; Spectralis, Heidelberg Engineering) and OCT angiography (OCTA; Avanti, Optovue RTVue XR) data from a single visit were analyzed. FAZ area, point thickness of central fovea, central 1-mm subfield thickness, the occurrence of intraretinal cysts, ellipsoid zone disruption, and disorganization of retinal inner layers (DRIL) length were measured. VA was also recorded. Correlations between FAZ area and VA were explored using regression models. Main outcome measure was VA. Mean age was 62.9±13.2 years. There was no difference in demographic and OCT-derived anatomic measurements between branch retinal vein occlusion and central retinal vein occlusion groups (all P ≥ 0.058); therefore, data from the 2 groups were pooled together to a single RVO group for further statistical comparisons. Univariate and multiple regression analysis showed that the area of the FAZ was significantly correlated with VA in DR and RVO (all P ≤ 0.003). The relationship between FAZ area and VA varied with age (P = 0.026) such that for a constant FAZ area, an increase in patient age was associated with poorer vision (rise in logarithm of the minimum angle of resolution visual acuity). Disruption of the ellipsoid zone was significantly correlated with VA in univariate and multiple regression analysis (both P < 0.001). Occurrence of intraretinal cysts, DRIL length, and lens status were significantly correlated with VA in the univariate regression analysis (P ≤ 0.018) but not the multiple regression analysis (P ≥ 0.210). Remaining variables evaluated in this study were not predictive of VA (all P ≥ 0.225). The area of the FAZ is

  12. Predictive Coding in Area V4: Dynamic Shape Discrimination under Partial Occlusion

    PubMed Central

    Choi, Hannah; Pasupathy, Anitha; Shea-Brown, Eric

    2018-01-01

    The primate visual system has an exquisite ability to discriminate partially occluded shapes. Recent electrophysiological recordings suggest that response dynamics in intermediate visual cortical area V4, shaped by feedback from prefrontal cortex (PFC), may play a key role. To probe the algorithms that may underlie these findings, we build and test a model of V4 and PFC interactions based on a hierarchical predictive coding framework. We propose that probabilistic inference occurs in two steps. Initially, V4 responses are driven solely by bottom-up sensory input and are thus strongly influenced by the level of occlusion. After a delay, V4 responses combine both feedforward input and feedback signals from the PFC; the latter reflect predictions made by PFC about the visual stimulus underlying V4 activity. We find that this model captures key features of V4 and PFC dynamics observed in experiments. Specifically, PFC responses are strongest for occluded stimuli and delayed responses in V4 are less sensitive to occlusion, supporting our hypothesis that the feedback signals from PFC underlie robust discrimination of occluded shapes. Thus, our study proposes that area V4 and PFC participate in hierarchical inference, with feedback signals encoding top-down predictions about occluded shapes. PMID:29566355

  13. Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.

    PubMed

    Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P

    2012-01-01

    The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.

  14. Occlusal factors are not related to self-reported bruxism.

    PubMed

    Manfredini, Daniele; Visscher, Corine M; Guarda-Nardini, Luca; Lobbezoo, Frank

    2012-01-01

    To estimate the contribution of various occlusal features of the natural dentition that may identify self-reported bruxers compared to nonbruxers. Two age- and sex-matched groups of self-reported bruxers (n = 67) and self-reported nonbruxers (n = 75) took part in the study. For each patient, the following occlusal features were clinically assessed: retruded contact position (RCP) to intercuspal contact position (ICP) slide length (< 2 mm was considered normal), vertical overlap (< 0 mm was considered an anterior open bite; > 4 mm, a deep bite), horizontal overlap (> 4 mm was considered a large horizontal overlap), incisor dental midline discrepancy (< 2 mm was considered normal), and the presence of a unilateral posterior crossbite, mediotrusive interferences, and laterotrusive interferences. A multiple logistic regression model was used to identify the significant associations between the assessed occlusal features (independent variables) and self-reported bruxism (dependent variable). Accuracy values to predict self-reported bruxism were unacceptable for all occlusal variables. The only variable remaining in the final regression model was laterotrusive interferences (P = .030). The percentage of explained variance for bruxism by the final multiple regression model was 4.6%. This model including only one occlusal factor showed low positive (58.1%) and negative predictive values (59.7%), thus showing a poor accuracy to predict the presence of self-reported bruxism (59.2%). This investigation suggested that the contribution of occlusion to the differentiation between bruxers and nonbruxers is negligible. This finding supports theories that advocate a much diminished role for peripheral anatomical-structural factors in the pathogenesis of bruxism.

  15. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    PubMed

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  16. Computer modeling of occlusal surfaces of posterior teeth with the CICERO CAD/CAM system.

    PubMed

    Olthoff, L W; Van Der Zel, J M; De Ruiter, W J; Vlaar, S T; Bosman, F

    2000-08-01

    Static and dynamic occlusal interference frequently needs to be corrected by selective grinding of the occlusal surface of conventional cast and ceramic-fused-to-metal restorations. CAD/CAM techniques allow control of the dimensional contours of these restorations. However, parameters responsible for the occlusal form need to be determined. In most articulators, these parameters are set as default values. Which technique is best for minimizing the introduction of occlusal interference in restorations has not been determined. This study investigated differences in crown structure of a crown designed in static occlusion (STA) with designs adapted for dynamic occlusal interferences. Therefore, values from an optoelectronic registration system (String-Condylocomp, KAVO), an occlusal generated path (OGP) technique and default settings (DEF) were used in the CICERO CAD/CAM system. Morphology of CON, DEF, and OGP crowns was compared with that of the STA crown with respect to differences in a buccolingual section and frequency of occlusal distances in an interocclusal range of 1 mm, measured from the occlusal surface of the crown. All crown types fulfilled the esthetic and morphologic criteria for restorations in clinical dentistry. Difference in the morphology of the OGP crown, compared with that of the STA crown, was greater than that for the CON and DEF crowns. These differences were seen especially in the distobuccal part of the occlusal surface; however, the number of occlusal contacts was considered sufficient to stabilize occlusion. Functional occlusion, adapted to dynamic occlusion in a CICERO crown for the first mandibular molar, can be obtained using data acquired with the String-Condylocomp registration system. The OGP technique was preferred to other techniques because of the simplicity of the technique for eliminating potential problems with opposing teeth during motion. However, this is achieved at the cost of fewer points of contact during occlusion than

  17. Effect of load, area of contact, and contact stress on the wear mechanisms of a bonded solid lubricant film

    NASA Technical Reports Server (NTRS)

    Fusaro, R. L.

    1980-01-01

    A pin on disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically tipped riders. Different projected contact stresses were obtained by applying loads of 2.5- to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build up of thick rider transfer films.

  18. Effect of load, area of contact, and contact stress on the tribological properties of polyimide bonded graphite fluoride films

    NASA Technical Reports Server (NTRS)

    Fusaro, R. L.

    1981-01-01

    A pin-on-disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide-bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically-tipped riders. Different projected contact stresses were obtained by applying loads of 2.5-to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build-up of thick rider transfer films.

  19. Transmission of vibration through gloves: effects of contact area.

    PubMed

    Md Rezali, Khairil Anas; Griffin, Michael J

    2017-01-01

    For three samples of material (12.5, 25.0 and 37.5 mm diameter) from each of three gloves, the dynamic stiffnesses and the vibration transmissibilities of the materials (to both the palm of the hand and the thenar eminence) were measured at frequencies from 10 to 300 Hz. Additional measurements showed the apparent masses of the hand at the palm and the thenar eminence were independent of contact area at frequencies less than about 40 Hz, but increased with increasing area at higher frequencies. The stiffness and damping of the glove materials increased with increasing area. These changes caused material transmissibilities to the hand to increase with increasing area. It is concluded that the size of the area of contact has a large influence on the transmission of vibration through a glove to the hand. The area of contact should be well-defined and controlled when evaluating the transmission of vibration through gloves. Practitioner Summary: The transmission of vibration through gloves depends on both the dynamic stiffness of glove material and the dynamic response of the hand. Both of these depend on the size of the contact area between a glove material and the hand, which should be taken into account when assessing glove transmissibility.

  20. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    PubMed Central

    2010-01-01

    Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p < 0.001). The changes in the mean HOP-BPOP differences on the x-axis (mediolateral) and the y-axis (anteroposterior) were significant (p < 0.05), whereas the change on the z-axis (superoinferior) was not significant (p > 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167

  1. A Novel Algorithm for Determining Contact Area Between a Respirator and a Headform

    PubMed Central

    Lei, Zhipeng; Yang, James; Zhuang, Ziqing

    2016-01-01

    The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P < 0.0001), and N95 FFR sizing systems influenced all contact area dimensions (P < 0.05) except the left and right chin regions. The medium headform produced the largest contact area, while the large and small headforms produced the smallest. PMID:24579752

  2. A novel algorithm for determining contact area between a respirator and a headform.

    PubMed

    Lei, Zhipeng; Yang, James; Zhuang, Ziqing

    2014-01-01

    The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P < 0.0001), and N95 FFR sizing systems influenced all contact area dimensions (P < 0.05) except the left and right chin regions. The medium headform produced the largest contact area, while the large and small headforms produced the smallest.

  3. An analytical method for computing atomic contact areas in biomolecules.

    PubMed

    Mach, Paul; Koehl, Patrice

    2013-01-15

    We propose a new analytical method for detecting and computing contacts between atoms in biomolecules. It is based on the alpha shape theory and proceeds in three steps. First, we compute the weighted Delaunay triangulation of the union of spheres representing the molecule. In the second step, the Delaunay complex is filtered to derive the dual complex. Finally, contacts between spheres are collected. In this approach, two atoms i and j are defined to be in contact if their centers are connected by an edge in the dual complex. The contact areas between atom i and its neighbors are computed based on the caps formed by these neighbors on the surface of i; the total area of all these caps is partitioned according to their spherical Laguerre Voronoi diagram on the surface of i. This method is analytical and its implementation in a new program BallContact is fast and robust. We have used BallContact to study contacts in a database of 1551 high resolution protein structures. We show that with this new definition of atomic contacts, we generate realistic representations of the environments of atoms and residues within a protein. In particular, we establish the importance of nonpolar contact areas that complement the information represented by the accessible surface areas. This new method bears similarity to the tessellation methods used to quantify atomic volumes and contacts, with the advantage that it does not require the presence of explicit solvent molecules if the surface of the protein is to be considered. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.

  4. Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts.

    PubMed

    Delong, Ralph; Ko, Ching-Chang; Anderson, Gary C; Hodges, James S; Douglas, W H

    2002-12-01

    Quantitative measures of occlusal contacts are of paramount importance in the study of chewing dysfunction. A tool is needed to identify and quantify occlusal parameters without occlusal interference caused by the technique of analysis. This laboratory simulation study compared occlusal contacts constructed from 3-dimensional images of dental casts and interocclusal records with contacts found by use of conventional methods. Dental casts of 10 completely dentate adults were mounted in a semi-adjustable Denar articulator. Maximum intercuspal contacts were marked on the casts using red film. Intercuspal records made with an experimental vinyl polysiloxane impression material recorded maximum intercuspation. Three-dimensional virtual models of the casts and interocclusal records were made using custom software and an optical scanner. Contacts were calculated between virtual casts aligned manually (CM), aligned with interocclusal records scanned seated on the mandibular casts (C1) or scanned independently (C2), and directly from virtual interocclusal records (IR). Sensitivity and specificity calculations used the marked contacts as the standard. Contact parameters were compared between method pairs. Statistical comparisons used analysis of variance and the Tukey-Kramer post hoc test (P=<.05). Sensitivities (range 0.76-0.89) did not differ significantly among the 4 methods (P=.14); however, specificities (range 0.89-0.98) were significantly lower for IR (P=.0001). Contact parameters of methods CM, C1, and C2 differed significantly from those of method IR (P<.02). The ranking based on method pair comparisons was C2/C1 > CM/C1 = CM/C2 > C2/IR > CM/IR > C1/IR, where ">" means "closer than." Within the limits of this study, occlusal contacts calculated from aligned virtual casts accurately reproduce articulator contacts.

  5. Experimental and numerical investigation of contact-area-limited doping for top-contact pentacene thin-film transistors with Schottky contact.

    PubMed

    Noda, Kei; Wada, Yasuo; Toyabe, Toru

    2015-10-28

    Effects of contact-area-limited doping for pentacene thin-film transistors with a bottom-gate, top-contact configuration were investigated. The increase in the drain current and the effective field-effect mobility was achieved by preparing hole-doped layers underneath the gold contact electrodes by coevaporation of pentacene and 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ), confirmed by using a thin-film organic transistor advanced simulator (TOTAS) incorporating Schottky contact with a thermionic field emission (TFE) model. Although the simulated electrical characteristics fit the experimental results well only in the linear regime of the transistor operation, the barrier height for hole injection and the gate-voltage-dependent hole mobility in the pentacene transistors were evaluated with the aid of the device simulation. This experimental data analysis with the simulation indicates that the highly-doped semiconducting layers prepared in the contact regions can enhance the charge carrier injection into the active semiconductor layer and concurrent trap filling in the transistor channel, caused by the mitigation of a Schottky energy barrier. This study suggests that both the contact-area-limited doping and the device simulation dealing with Schottky contact are indispensable in designing and developing high-performance organic thin-film transistors.

  6. Development of a computational technique to measure cartilage contact area.

    PubMed

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. On crack growth in molar teeth from contact on the inclined occlusal surface.

    PubMed

    Chai, Herzl

    2015-04-01

    Extracted human molar teeth are indented by hard balls laid at the central fossa, sectioned, and their interior examined for damage. Contact on the fissured enamel coat generally occurs on three distinct spots. The main forms of damage are radial cracks growing from the DEJ to the occlusal surface and median radial and cylindrical cracks growing from a contact spot to the DEJ. For large balls failure by edge chipping near a cusp apex may occur. The median cracks tend to run unstably to the DEJ upon reaching the middle part of the enamel coat. The corresponding load, PFM, and the load needed to initiate radial cracks at the DEJ, PFR, are taken to signal crown failure. The mean values of PFM and PFR are on the order of 1000N. A conical bilayer model defined by thickness d, inclination angle θ, failure stress σF and toughness KC of the enamel coat is developed to assess crown failure. The analytical predictions for PFR and PFM agree well with the tests. The results indicate that enamel thickness is so designed as to ensure that PFR and PFM just exceed the maximum bite force under normal conditions while the choice of θ seems to reflect a compromise between needs to resist crown failure and break hard food particles. Both PFR and PFM are greatly reduced with reducing d, which points to the danger posed by tooth wear. The analytical expressions for PFR and PFM may also apply to other multi-cusp mammalian or prosthetic molar crowns. Cone cracking, suppressed in the anisotropic tooth enamel, may be an important failure mode in prosthetic crowns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Comparison of excursive occlusal force parameters in post-orthodontic and non-orthodontic subjects using T-Scan® III.

    PubMed

    Qadeer, Sarah; Abbas, Ahmed A; Sarinnaphakorn, Lertrit; Kerstein, Robert B

    2018-01-01

    Published studies indicate that orthodontically treated patients demonstrate increased posterior occlusal friction contributing to temporomandibular disorder (TMD) symptoms. This study investigated measured excursive movement occlusal contact parameters and their association with TMD symptoms between non- and post-orthodontic subjects. Twenty-five post-orthodontic and 25 non-orthodontic subjects underwent T-Scan® computerized occlusal analysis to determine their disclusion time (DT), the excursive frictional contacts, and occlusal scheme. Each subject answered a TMD questionnaire to determine the presence or absence of TMD symptoms. Statistical analysis compared the within group and between group differences (p < 0.05). Statistically significant differences were observed in the disclusion time: DT = 2.69 s in the post-orthodontic and 1.36 s in the non-orthodontic group. In the non-orthodontic group, 72.7% working and 27.3% non-working side contacts were seen, while in the post-orthodontic group, (near equal) 54.7% working and 45.3% non-working side contacts were seen. Presence of canine guidance was seen in 60% of the non-orthodontic group and 24% in the post-orthodontic group. Seventy-two percent of the post orthodontics subjects presented with one or more TMD symptoms. Significantly longer disclusion time, higher posterior frictional contacts, and more TMD symptoms were observed in the post-orthodontic group, suggesting that orthodontic treatment increases posterior tooth friction. Computerized occlusal analysis is an objective diagnostic tool determining the quality of excursive movements following orthodontic treatment.

  9. Changes of contact pressure and area in patellofemoral joint after different meniscectomies.

    PubMed

    Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni

    2012-05-01

    We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.

  10. Occlusal wear and occlusal condition in a convenience sample of young adults.

    PubMed

    Van't Spijker, A; Kreulen, C M; Bronkhorst, E M; Creugers, N H J

    2015-01-01

    To study progression of tooth wear quantitatively in a convenient sample of young adults and to assess possible correlations with occlusal conditions. Twenty-eight dental students participated in a three-year follow up study on tooth wear. Visible wear facets on full arch gypsum casts were assessed using a flatbed scanner and measuring software. Regression analyses were used to assess possible associations between the registered occlusal conditions 'occlusal guidance scheme', 'vertical overbite', 'horizontal overbite', 'depth of sagittal curve', 'canine Angle class relation', 'history of orthodontic treatment', and 'self-reported grinding/clenching' (independent variables) and increase of wear facets (dependent variable). Mean increase in facet surface areas ranged from 1.2 mm2 (premolars, incisors) to 3.4 mm2 (molars); the relative increase ranged from 15% to 23%. Backward regression analysis showed no significant relation for 'group function', 'vertical overbite', 'depth of sagittal curve', 'history of orthodontic treatment' nor 'self-reported clenching. The final multiple linear regression model showed significant associations amongst 'anterior protected articulation' and 'horizontal overbite' and increase of facet surface areas. For all teeth combined, only 'anterior protected articulation' had a significant effect. 'Self reported grinding' did not have a significant effect (p>0.07). In this study 'anterior protected articulation' and 'horizontal overbite', were significantly associated with the progression of tooth wear. Self reported grinding was not significantly associated with progression of tooth wear. Occlusal conditions such as anterior protected articulation and horizontal overbite seem to have an effect on the progression of occlusal tooth wear in this convenient sample of young adults. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms.

    PubMed

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-12-01

    The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as "decreased," "slightly decreased," and "preserved". Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P<0.001) between the two groups. HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group (33.8 ± 8.2 HU vs. 11.9 ± 6.1 HU, P<0.001). There was no significant difference in HUs for the entire lesion between the non-occlusive (33.8 ± 8.2 HU) and corresponding normal group (34.5 ± 6.8 HU; P=0.294). Iodine perfusion tended to be visually and quantitatively preserved in lungs with

  12. The effect of elastic modulus on ablation catheter contact area.

    PubMed

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  13. Articular Contact Area and Pressure in Posteromedial Rotatory Instability of the Elbow.

    PubMed

    Bellato, Enrico; Fitzsimmons, James S; Kim, Youngbok; Bachman, Daniel R; Berglund, Lawrence J; Hooke, Alexander W; O'Driscoll, Shawn W

    2018-03-21

    Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm to 150 ± 58 mm (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in

  14. Evaluation of the Alteration of Occlusal Distribution in Unilateral Free-End and Intermediate Missing Cases.

    PubMed

    Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei

    2017-02-01

    The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.

  15. Can foot anthropometric measurements predict dynamic plantar surface contact area?

    PubMed

    McPoil, Thomas G; Vicenzino, Bill; Cornwall, Mark W; Collins, Natalie

    2009-10-28

    Previous studies have suggested that increased plantar surface area, associated with pes planus, is a risk factor for the development of lower extremity overuse injuries. The intent of this study was to determine if a single or combination of foot anthropometric measures could be used to predict plantar surface area. Six foot measurements were collected on 155 subjects (97 females, 58 males, mean age 24.5 +/- 3.5 years). The measurements as well as one ratio were entered into a stepwise regression analysis to determine the optimal set of measurements associated with total plantar contact area either including or excluding the toe region. The predicted values were used to calculate plantar surface area and were compared to the actual values obtained dynamically using a pressure sensor platform. A three variable model was found to describe the relationship between the foot measures/ratio and total plantar contact area (R2 = 0.77, p < 0.0001)). A three variable model was also found to describe the relationship between the foot measures/ratio and plantar contact area minus the toe region (R2 = 0.76, p < 0.0001). The results of this study indicate that the clinician can use a combination of simple, reliable, and time efficient foot anthropometric measurements to explain over 75% of the plantar surface contact area, either including or excluding the toe region.

  16. Can foot anthropometric measurements predict dynamic plantar surface contact area?

    PubMed Central

    2009-01-01

    Background Previous studies have suggested that increased plantar surface area, associated with pes planus, is a risk factor for the development of lower extremity overuse injuries. The intent of this study was to determine if a single or combination of foot anthropometric measures could be used to predict plantar surface area. Methods Six foot measurements were collected on 155 subjects (97 females, 58 males, mean age 24.5 ± 3.5 years). The measurements as well as one ratio were entered into a stepwise regression analysis to determine the optimal set of measurements associated with total plantar contact area either including or excluding the toe region. The predicted values were used to calculate plantar surface area and were compared to the actual values obtained dynamically using a pressure sensor platform. Results A three variable model was found to describe the relationship between the foot measures/ratio and total plantar contact area (R2 = 0.77, p < 0.0001)). A three variable model was also found to describe the relationship between the foot measures/ratio and plantar contact area minus the toe region (R2 = 0.76, p < 0.0001). Conclusion The results of this study indicate that the clinician can use a combination of simple, reliable, and time efficient foot anthropometric measurements to explain over 75% of the plantar surface contact area, either including or excluding the toe region. PMID:19863799

  17. Growth of contact area between rough surfaces under normal stress

    NASA Astrophysics Data System (ADS)

    Stesky, R. M.; Hannan, S. S.

    1987-05-01

    The contact area between deforming rough surfaces in marble, alabaster, and quartz was measured from thin sections of surfaces bonded under load with low viscosity resin epoxy. The marble and alabaster samples had contact areas that increased with stress at an accelerating rate. This result suggests that the strength of the asperity contacts decreased progressively during the deformation, following some form of strain weakening relationship. This conclusion is supported by petrographic observation of the thin sections that indicate that much of the deformation was cataclastic, with minor twinning of calcite and kinking of gypsum. In the case of the quartz, the observed contact area was small and increased approximately linearly with normal stress. Only the irreversible cataclastic deformation was observed; however strain-induced birefringence and cracking of the epoxy, not observed with the other rocks, suggests that significant elastic deformation occurred, but recovered during unloading.

  18. Role of Firing Temperature, Sheet Resistance, and Contact Area in Contact Formation on Screen-Printed Metal Contact of Silicon Solar Cell

    NASA Astrophysics Data System (ADS)

    Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.

    2018-03-01

    Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.

  19. The steady-state tangential contact problem for a falling drop type of contact area on corrugated rail by simplified theory of rolling contact

    NASA Astrophysics Data System (ADS)

    Piotrowski, Jerzy

    1991-10-01

    Investigation of contact mechanical nonlinearities of a mathematical model of corrugation revealed that the typical shape of contact patch resembles a falling drop of water. A contact patch of that shape was approximated with a figure composed of two parts of ellipses with different eccentricities. The contact pressure distribution was assumed as a smoothing ensemble of two paraboloidal distributions. The description of a general case of double half elliptical contact area was given but a special case of double half elliptical contact is more interesting as it possesses some Hertzian properties. It was shown how three geometrical parameters of double half elliptical contact can be chosen when actual, non-Hertzian contact is known. A linear theory was written which indicates that the lateral vibrations of the rail may be excited only due to shape variation on corrugation even if any other cause for these vibrations does not exist. For nonlinear theory a computer program, based on FASTSIM algorithm by Kalker, was written. The aim is to calculate the creep forces and frictional power density distribution over the contact area. Also, a graphic program visualizing the solution was written. Numerical results are not provided; unattended and unsolved problems relevant for this type of contact are listed.

  20. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    PubMed

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (< 60 years old) and elderly (60 years old or more) patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  1. Changes in Contact Area in Meniscus Horizontal Cleavage Tears Subjected to Repair and Resection.

    PubMed

    Beamer, Brandon S; Walley, Kempland C; Okajima, Stephen; Manoukian, Ohan S; Perez-Viloria, Miguel; DeAngelis, Joseph P; Ramappa, Arun J; Nazarian, Ara

    2017-03-01

    To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P < .03). There was approximately a 70% increase in contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P < .05). Partial meniscectomy and subtotal meniscectomy significantly increased average peak contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P < .05). The presence of a horizontal cleavage tear in the medial meniscus causes a significant reduction in contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. Understanding contact area and peak contact pressure resulting from differing strategies

  2. Large area optical mapping of surface contact angle.

    PubMed

    Dutra, Guilherme; Canning, John; Padden, Whayne; Martelli, Cicero; Dligatch, Svetlana

    2017-09-04

    Top-down contact angle measurements have been validated and confirmed to be as good if not more reliable than side-based measurements. A range of samples, including industrially relevant materials for roofing and printing, has been compared. Using the top-down approach, mapping in both 1-D and 2-D has been demonstrated. The method was applied to study the change in contact angle as a function of change in silver (Ag) nanoparticle size controlled by thermal evaporation. Large area mapping reveals good uniformity for commercial Aspen paper coated with black laser printer ink. A demonstration of the forensic and chemical analysis potential in 2-D is shown by uncovering the hidden CsF initials made with mineral oil on the coated Aspen paper. The method promises to revolutionize nanoscale characterization and industrial monitoring as well as chemical analyses by allowing rapid contact angle measurements over large areas or large numbers of samples in ways and times that have not been possible before.

  3. Contact resistance improvement by the modulation of peripheral length to area ratio of graphene contact pattern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cho, Chunhum; Lee, Sangchul; Lee, Sang Kyung

    2015-05-25

    High contact resistance between graphene and metal is a major huddle for high performance electronic device applications of graphene. In this work, a method to improve the contact resistance of graphene is investigated by varying the ratio of peripheral length and area of graphene pattern under a metal contact. The contact resistance decreased to 0.8 kΩ·μm from 2.1 kΩ·μm as the peripheral length increased from 312 to 792 μm. This improvement is attributed to the low resistivity of edge-contacted graphene, which is 8.1 × 10{sup 5} times lower than that of top-contacted graphene.

  4. Prosthetic occlusive device for an internal passageway

    NASA Technical Reports Server (NTRS)

    Tenney, J. B., Jr. (Inventor)

    1983-01-01

    An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.

  5. Labral reconstruction with iliotibial band autografts and semitendinosus allografts improves hip joint contact area and contact pressure: an in vitro analysis.

    PubMed

    Lee, Simon; Wuerz, Thomas H; Shewman, Elizabeth; McCormick, Frank M; Salata, Michael J; Philippon, Marc J; Nho, Shane J

    2015-01-01

    Labral reconstruction using iliotibial band (ITB) autografts and semitendinosus (Semi-T) allografts has recently been described in cases of labral deficiency. To characterize the joint biomechanics with a labrum-intact, labrum-deficient, and labrum-reconstructed acetabulum in a hip cadaveric model. The hypothesis was that labral resection would decrease contact area, increase contact pressure, and increase peak force, while subsequent labral reconstruction with ITB autografts or Semi-T allografts would restore these values toward the native intact labral state. Controlled laboratory study. Ten fresh-frozen human cadaveric hips were analyzed utilizing thin-film piezoresistive load sensors to measure contact area, contact pressure, and peak force (1) with the native intact labrum, (2) after segmental labral resection, and (3) after graft labral reconstruction with either ITB autografts or Semi-T allografts. Each specimen was examined at 20° of extension and 60° of flexion. Statistical analysis was conducted through 1-way analysis of variance with post hoc Games-Howell tests. For the ITB group, labral resection significantly decreased contact area (at 20°: 73.2%±5.38%, P=.0010; at 60°: 78.5%±6.93%, P=.0063) and increased contact pressure (at 20°: 106.7%±4.15%, P=.0387; at 60°: 103.9%±1.15%, P=.0428). In addition, ITB reconstruction improved contact area (at 20°: 87.2%±12.3%, P=.0130; at 60°: 90.5%±8.81%, P=.0079) and contact pressure (at 20°: 98.5%±5.71%, P=.0476; at 60°: 96.6%±1.13%, P=.0056) from the resected state. Contact pressure at 60° of flexion was significantly lower compared with the native labrum (P=.0420). For the Semi-T group, labral resection significantly decreased contact area (at 20°: 68.1%±12.57%, P=.0002; at 60°: 67.5%±6.70%, P=.0002) and increased contact pressure (at 20°: 105.3%±3.73%, P=.0304; at 60°: 106.8%±4.04%, P=.0231). Semi-T reconstruction improved contact area (at 20°: 87.9%±7.95%, P=.0087; at 60°: 92.9%±13

  6. Atomistic simulations of contact area and conductance at nanoscale interfaces.

    PubMed

    Hu, Xiaoli; Martini, Ashlie

    2017-11-09

    Atomistic simulations were used to study conductance across the interface between a nanoscale gold probe and a graphite surface with a step edge. Conductance on the graphite terrace was observed to increase with load and be approximately proportional to contact area calculated from the positions of atoms in the interface. The relationship between area and conductance was further explored by varying the position of the contact relative to the location of the graphite step edge. These simulations reproduced a previously-reported current dip at step edges measured experimentally and the trend was explained by changes in both contact area and the distribution of distances between atoms in the interface. The novel approach reported here provides a foundation for future studies of the fundamental relationships between conductance, load and surface topography at the atomic scale.

  7. Sociocultural and psychological determinants in migrants for noncompliance with occlusion therapy for amblyopia.

    PubMed

    Tjiam, Angela M; Akcan, Hilal; Ziylan, Fatma; Vukovic, Elizabet; Loudon, Sjoukje E; Looman, Caspar W N; Passchier, Jan; Simonsz, Huibert J

    2011-12-01

    Compliance with occlusion therapy for amblyopia in children is low when their parents have a low level of education, speak Dutch poorly, or originate from another country. We determined how sociocultural and psychological determinants affect compliance. Included were amblyopic children between the ages of 3 and 6, living in low socio-economic status (SES) areas. Compliance with occlusion therapy was measured electronically. Their parents completed an oral questionnaire, based on the "Social Position & Use of Social Services by Migrants and Natives" questionnaire that included demographics and questions on issues like education, employment, religion and social contacts. Parental fluency in Dutch was rated on a five-point scale. Regression analysis was used to describe the relationship between the level of compliance and sociocultural and psychological determinants. Data from 45 children and their parents were analyzed. Mean electronically measured compliance was 56 ± 44 percent. Children whose parents had close contact with their neighbors or who were highly dependent on their family demonstrated low levels of compliance. Children of parents who were members of a club and who had positive conceptualizations of Dutch society showed high levels of compliance. Poor compliance was also associated with low income, depression, and when patching interfered with the child's outdoor activity. Religion was not associated with compliance. Poor compliance with occlusion therapy seems correlated with indicators of social cohesion. High social cohesion at micro level, i.e., family, neighbors and friends, and low social cohesion on macro level, i.e., Dutch society, are associated with noncompliance. However, such parents tend to speak Dutch poorly, so it is difficult to determine its actual cause.

  8. Effects of medial meniscus posterior horn avulsion and repair on tibiofemoral contact area and peak contact pressure with clinical implications.

    PubMed

    Marzo, John M; Gurske-DePerio, Jennifer

    2009-01-01

    Avulsion of the posterior horn attachment of the medial meniscus can compromise load-bearing ability, produce meniscus extrusion, and result in tibiofemoral joint-space narrowing, articular cartilage damage, and osteoarthritis. Avulsion of the posterior horn of the medial meniscus will increase peak contact pressure and decrease contact area in the medial compartment of the knee, and posterior horn repair will restore contact area and peak contact pressures to values of the control knee. Controlled laboratory study. Eight fresh-frozen human cadaveric knees had tibiofemoral peak contact pressures and contact area measured in the control state. The posterior horn of the medial meniscus was avulsed from its insertion and knees were retested. The meniscal avulsion was repaired by suture through a transosseous tunnel and the knees were tested a third time. Avulsion of the posterior horn attachment of the medial meniscus resulted in a significant increase in medial joint peak contact pressure (from 3841 kPa to 5084 kPa) and a significant decrease in contact area (from 594 mm(2) to 474 mm(2)). Repair of the avulsion resulted in restoration of the loading profiles to values equal to the control knee, with values of 3551 kPa for peak pressure and 592 mm(2) for contact area. Posterior horn medial meniscal root avulsion leads to deleterious alteration of the loading profiles of the medial joint compartment and results in loss of hoop stress resistance, meniscus extrusion, abnormal loading of the joint, and early knee medial-compartment degenerative changes. The repair technique described restores the ability of the medial meniscus to absorb hoop stress and eliminate joint-space narrowing, possibly decreasing the risk of degenerative disease.

  9. High inter-specimen variability of baseline data for the tibio-talar contact area.

    PubMed

    Matricali, Giovanni A; Bartels, Ward; Labey, Luc; Dereymaeker, Greta Ph E; Luyten, Frank P; Vander Sloten, Jos

    2009-01-01

    The tibio-talar contact area has been widely investigated to monitor biomechanical changes due to articular incongruities or an altered loading. This study aims to investigate for the first time in a systematic way the extent of the inter-specimen variability of the tibio-talar contact area, and its repercussions when analyzing data concerning this parameter. Ten specimens were loaded to record the tibio-talar contact characteristics by use of pressure sensitive film. The size of the talar dome area, the size of the (normalized) tibio-talar contact area, the position of the tibio-talar contact area, and the shape of the latter were determined and analyzed. Inter-specimen variability was expressed as the coefficient of variation and was calculated for the datasets of previous studies as well. The size of the tibio-talar contact area showed a very high inter-specimen variability, as is the case in previous studies. This high variability persisted when a normalized tibio-talar contact area was calculated. The shape of the tibio-talar contact area showed some basic characteristics, but a high variation in details could be observed. Every specimen can be considered to have its own "ankle print". By this variability, articular incongruities are expected to have a different effect on local biomechanical characteristics in every single individual. Therefore, every single case has to be evaluated and reported for significant changes. In case of modeling, this also underscores the need to use subject specific models fed by sets of parameters derived from a series of single specimens.

  10. Effect of contact area on electron transport through graphene-metal interface.

    PubMed

    Liu, Hongmei; Kondo, Hisashi; Ohno, Takahisa

    2013-08-21

    We perform first-principles investigations of electron transport in armchair graphene nanoribbons adsorbed on Cu(111) and Ni(111) surfaces with various contact areas. We find that the contact area between metals and graphene has different influences on the conductance. The Cu-graphene system shows an increase in differential conductance for more contact area at a low bias voltage, primarily originating from the shift of transmission peaks relative to the Fermi energy. As the bias increases, there is an irregular change of conductance, including a weak negative differential conductance for more contact area. In contrast, the conductance of the Ni-graphene junction is monotonically enhanced with increasing overlap area. The minority spin which shows a broad transmission is responsible for the conductance increase of Ni-graphene. These behaviors can be attributed to different mechanisms of the interfacial electron transport: Charge transfer between graphene and Cu largely dominates the transmission enhancement of Cu-graphene, whereas hybridization between graphene and Ni states plays a more important role in the transmission enhancement of Ni-graphene. The different behaviors of transmission increase correlate with not only the strength of the graphene-metal interaction but also the location of metal d states.

  11. Necrotizing Fasciitis of the Periorbital Region Complicated by Combined Central Retinal Artery Occlusion, Central Retinal Vein Occlusion, and Posterior Ciliary Occlusion.

    PubMed

    Sultan, Harris; Malik, Amina; Li, Helen K; Chévez-Barrios, Patricia; Lee, Andrew G

    A 50 year-old man on immunosuppressive agents presented with left eye vision loss, periorbital swelling, pain, and ophthalmoplegia. The patient was clinically found to have a central retinal artery and vein occlusion. A CT scan was performed which demonstrated intraorbital fat stranding, however the patient lacked sinus disease. The etiology of the orbital infection was held in question. The area was debrided in the operating room, and the specimen demonstrated group A streptococcal species consistent with necrotizing fasciitis. Periorbital necrotizing fasciitis should be suspected in patients with rapidly progressive orbital symptoms without sinus disease as lack of surgical intervention can result in poor outcomes. The unusual aspect to this case is the mechanism of vision loss, as the authors hypothesize that there was vascular infiltration of the infection resulting in the central retinal artery occlusion and central retinal vein occlusion which have not been previously reported secondary to necrotizing fasciitis of the orbit.

  12. Microscopic contact area and friction between medical textiles and skin.

    PubMed

    Derler, S; Rotaru, G-M; Ke, W; El Issawi-Frischknecht, L; Kellenberger, P; Scheel-Sailer, A; Rossi, R M

    2014-10-01

    The mechanical contact between medical textiles and skin is relevant in the health care for patients with vulnerable skin or chronic wounds. In order to gain new insights into the skin-textile contact on the microscopic level, the 3D surface topography of a normal and a new hospital bed sheet with a regular surface structure was measured using a digital microscope. The topographic data was analysed concerning material distribution and real contact area against smooth surfaces as a function of surface deformations. For contact conditions that are relevant for the skin of patients lying in a hospital bed it was found that the order of magnitude of the ratio of real and apparent contact area between textiles and skin or a mechanical skin model lies between 0.02 and 0.1 and that surface deformations, i.e. penetration of the textile surface asperities into skin or a mechanical skin model, range from 10 to 50µm. The performed analyses of textile 3D surface topographies and comparisons with previous friction measurement results provided information on the relationship between microscopic surface properties and macroscopic friction behaviour of medical textiles. In particular, the new bed sheet was found to be characterised by a trend towards a smaller microscopic contact area (up to a factor of two) and by a larger free interfacial volume (more than a factor of two) in addition to a 1.5 times lower shear strength when in contact with counter-surfaces. The applied methods can be useful to develop improved and skin-adapted materials and surfaces for medical applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Progression of Diabetic Capillary Occlusion: A Model

    PubMed Central

    Gens, John Scott; Glazier, James A.; Burns, Stephen A.; Gast, Thomas J.

    2016-01-01

    An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions. PMID:27300722

  14. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    PubMed Central

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  15. Time Sequence Evaluation of Biliary Stent Occlusion by Dissection Analysis of Retrieved Stents.

    PubMed

    Kwon, Chang-Il; Gromski, Mark A; Sherman, Stuart; Easler, Jeffrey J; El Hajj, Ihab I; Watkins, James; Fogel, Evan L; McHenry, Lee; Lehman, Glen A

    2016-08-01

    Multiple factors can affect the occlusion of plastic stents. Previous data demonstrate that side holes may induce more biofilm formation probably via microturbulence and bile flow disturbances that could lead to occlusion. These results, however, have not been replicated in subsequent clinical studies with different methods. The objective of this study is to evaluate the physical characteristics of plastic stent occlusion over time. This is a plastic stent sequential analysis study. Biliary stents removed via ERCP from February 24, 2015, to June 2, 2015, were included. One hundred and forty-eight retrieved straight-type plastic stents were longitudinally cut by a custom-made cutting device. These dissected stents were then evaluated in detail with regard to the location of stent occlusion and the stent patency period. Location of stent occlusive debris was the primary outcome in this study. Biofilm formations and occlusions by debris were sequentially but separately tallied. Biofilm formations were initially seen around the side hole areas within 30 days and spread to the entire stent by 60 days. Then, occlusion process by debris was mainly initiated by 80 days and progressed to full occlusion by median of 90 days. Although some occlusions were also observed around the side hole areas within 30 days, affected areas were more widely observed after biofilm formation. This study is the first to attempt to describe the distribution of stent occlusions over time. These observations may help guide future stent development.

  16. Mechanical behavior of CAD/CAM occlusal ceramic reconstruction assessed by digital color holography.

    PubMed

    Xia, H; Picart, P; Montresor, S; Guo, R; Li, J C; Yusuf Solieman, O; Durand, J-C; Fages, M

    2018-05-21

    CAD/CAM ceramic occlusal veneers are increasingly used as therapeutic options. However, little is known about their mechanical behavior under stress, as the response of the prepared tooth that supports it. The aim of this article is to use for the first time 3D color holography to evaluate the behavior of a molar occlusal veneer under stress and the response of the prepared tooth. The occlusal surface of a lower molar is prepared to receive a specific monolithic ceramic reconstruction manufactured with a chairside CAD/CAM system. Longitudinally cut samples are used to get a planar object observation and to "look inside" the tooth. A digital holographic set-up permits to obtain the contact-less and one-shot measurement of the three-dimensional displacement field at the surface of the tooth sample; stain fields are evaluated with low noise-sensitive computation. Figures show the strain fields with micro-strain units and highlight the behavior of the ROI (region of interest) in the three directions of space. The ROI are: the ceramic, the glue junction, the dentin enamel junction, dentin and enamel. The results show an excellent behavior of the restored tooth without areas of excessive stress concentrations, but also a significant involvement of the dentin enamel junction. The ceramic occlusal veneer seems to behave in accordance with the biomechanical concepts ensuring the longevity of the reconstituted tooth. 3D holography is a highly recommended method for studying dental biomechanics. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  17. Cell-cell contact area affects Notch signaling and Notch-dependent patterning

    PubMed Central

    Shaya, Oren; Binshtok, Udi; Hersch, Micha; Rivkin, Dmitri; Weinreb, Sheila; Amir-Zilberstein, Liat; Khamaisi, Bassma; Oppenheim, Olya; Desai, Ravi A.; Goodyear, Richard J.; Richardson, Guy P.; Chen, Christopher S.; Sprinzak, David

    2017-01-01

    Summary During development, cells undergo dramatic changes in their morphology. By affecting contact geometry, these morphological changes could influence cellular communication. However, it has remained unclear whether and how signaling depends on contact geometry. This question is particularly relevant for Notch signaling, which coordinates neighboring cell fates through direct cell-cell signaling. Using micropatterning with a receptor trans-endocytosis assay, we show that signaling between pairs of cells correlates with their contact area. This relationship extends across contact diameters ranging from microns to tens of microns. Mathematical modeling predicts that dependence of signaling on contact area can bias cellular differentiation in Notch-mediated lateral inhibition processes, such that smaller cells are more likely to differentiate into signal-producing cells. Consistent with this prediction, analysis of developing chick inner ear revealed that ligand-producing hair cell precursors have smaller apical footprints than non-hair cells. Together, these results highlight the influence of cell morphology on fate determination processes. PMID:28292428

  18. Cell-Cell Contact Area Affects Notch Signaling and Notch-Dependent Patterning.

    PubMed

    Shaya, Oren; Binshtok, Udi; Hersch, Micha; Rivkin, Dmitri; Weinreb, Sheila; Amir-Zilberstein, Liat; Khamaisi, Bassma; Oppenheim, Olya; Desai, Ravi A; Goodyear, Richard J; Richardson, Guy P; Chen, Christopher S; Sprinzak, David

    2017-03-13

    During development, cells undergo dramatic changes in their morphology. By affecting contact geometry, these morphological changes could influence cellular communication. However, it has remained unclear whether and how signaling depends on contact geometry. This question is particularly relevant for Notch signaling, which coordinates neighboring cell fates through direct cell-cell signaling. Using micropatterning with a receptor trans-endocytosis assay, we show that signaling between pairs of cells correlates with their contact area. This relationship extends across contact diameters ranging from micrometers to tens of micrometers. Mathematical modeling predicts that dependence of signaling on contact area can bias cellular differentiation in Notch-mediated lateral inhibition processes, such that smaller cells are more likely to differentiate into signal-producing cells. Consistent with this prediction, analysis of developing chick inner ear revealed that ligand-producing hair cell precursors have smaller apical footprints than non-hair cells. Together, these results highlight the influence of cell morphology on fate determination processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The Change in Fingertip Contact Area as a Novel Proprioceptive Cue.

    PubMed

    Moscatelli, Alessandro; Bianchi, Matteo; Serio, Alessandro; Terekhov, Alexander; Hayward, Vincent; Ernst, Marc O; Bicchi, Antonio

    2016-05-09

    Humans, many animals, and certain robotic hands have deformable fingertip pads [1, 2]. Deformable pads have the advantage of conforming to the objects that are being touched, ensuring a stable grasp for a large range of forces and shapes. Pad deformations change with finger displacements during touch. Pushing a finger against an external surface typically provokes an increase of the gross contact area [3], potentially providing a relative motion cue, a situation comparable to looming in vision [4]. The rate of increase of the area of contact also depends on the compliance of the object [5]. Because objects normally do not suddenly change compliance, participants may interpret an artificially induced variation in compliance, which coincides with a change in the gross contact area, as a change in finger displacement, and consequently they may misestimate their finger's position relative to the touched object. To test this, we asked participants to compare the perceived displacements of their finger while contacting an object varying pseudo-randomly in compliance from trial to trial. Results indicate a bias in the perception of finger displacement induced by the change in compliance, hence in contact area, indicating that participants interpreted the altered cutaneous input as a cue to proprioception. This situation highlights the capacity of the brain to take advantage of knowledge of the mechanical properties of the body and of the external environment. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Occlusion, sternocleidomastoid muscle activity, and body sway: a pilot study in male astronauts.

    PubMed

    Sforza, Chiarella; Tartaglia, Gianluca M; Solimene, Umberto; Morgun, Valery; Kaspranskiy, Rustem R; Ferrario, Virgilio F

    2006-01-01

    The modifications induced by microgravity on the coordinated patterns of movement of the head, trunk, and limbs are reported on extensively. However, apparently there is little data on the masticatory muscles. In normal gravitational conditions, information from the neck and stomatognathic apparatus play a role in maintaining the body's balance and equilibrium. The current pilot study used normal gravity conditions to investigate the hypothesis of a functional coupling between occlusion and neck muscles and body postural oscillations. The immediate effect of modified occlusal surfaces on the contraction pattern of the sternocleidomastoid muscles during maximum voluntary clenching and on the oscillation of the center of foot pressure was analyzed in 11 male astronauts (aged 31-54 yrs). All subjects were healthy and free from pathologies of the neck and stomatognathic apparatus. Occlusal splints were prepared using impressions of their dental arches. The splints were modeled on the mandibular arch, had only posterior contacts, and were modified to obtain a more symmetric, standardized contraction of the masseter and temporalis muscles during teeth clenching. Surface EMG activity of the sternocleidomastoid muscles was recorded during a maximal voluntary clench with and without the splint. Sternocleidomastoid potentials were standardized as percent of the mean potentials recorded during a maximum contralateral rotation of the head, and the symmetry of the EMG waves of left- and right-side muscles was measured. Body sway was assessed with and without the splint, either with eyes open or closed. The variations of the center of foot pressure were analyzed through bivariate analysis, and the area of the 90% standard ellipse was computed. Within each visual condition (eyes open or closed), the difference between the areas of oscillation measured with and without the splint was computed. Muscular activity was more symmetric with the splint. The area of oscillation of the

  1. Tight contact technique during side-to-side laser tissue soldering of rabbit aortas improves tensile strength.

    PubMed

    Alfieri, A; Bregy, A; Constantinescu, M; Stuker, F; Schaffner, T; Frenz, M; Banic, A; Reinert, M

    2008-01-01

    Cerebral revascularization may be indicated either for blood flow preservation or flow augmentation, often in clinical situations where neither endovascular nor standard surgical intervention can be performed. Cerebral revascularization can be performed by using a temporary occlusive or a non-occlusive technique. Both of these possibilities have their specific range of feasibility. Therefore non-occlusive revascularization techniques have been developed. To further reduce the risks for patients, less time consuming, sutureless techniques such as laser tissue soldering are currently being investigated. In the present study, a new technique for side-to-side anastomosis was developed. Using a "sandwich technique", two vessels are kept in close contact during the laser soldering. Thoraco-abdominal aortas from 24 different rabbits were analyzed for laser irradiation induced tensile strength. Two different irradiation modes (continuous and pulsed) were used. The results were compared to conventional, noncontact laser soldering. Histology was performed using HE, Mason's Trichrome staining. The achieved tensile strengths were significantly higher using the close contact "sandwich technique" as compared to the conventional adaptation technique. Furthermore, tensile strength was higher in the continuously irradiated specimen as compared to the specimen undergoing pulsed laser irradiation. The histology showed similar denaturation areas in both groups. The addition of a collagen membrane between vessel components reduced the tensile strength. These first results proved the importance of close and tight contact during the laser soldering procedure thus enabling the development of a "sandwich laser irradiation device" for in vivo application in the rabbit.

  2. The relationship between area deprivation and contact with community intellectual disability psychiatry.

    PubMed

    Nicholson, L; Hotchin, H

    2015-05-01

    People with intellectual disabilities (ID) have high rates of psychiatric illness and are known to live in more deprived areas than the general population. This study investigated the relationship between area deprivation and contact with ID psychiatry. Psychiatric case notes and electronic records were used to identify all patients who had face-to-face contact with community ID psychiatric services over 1 year in the North East Community Health Partnership of Greater Glasgow and Clyde (estimated population 177,867). The Scottish Index of Multiple Deprivation (SIMD) were determined for the patient sample and for the general population living in the same area. Between 1 June 2012 and 1 June 2013, 184 patients were seen by ID psychiatry over a total of 553 contacts, with valid SIMD data for 179 patients and 543 contacts. Fifty-two per cent of patients (n = 93) lived in the most deprived SIMD decile, and 90.5% (n = 152) in the lowest 5 deciles. Compared with the general population, there were significantly more patients than expected living in the most deprived decile (Fisher's Exact test, P = 0.009) and in the most deprived 5 deciles (Fisher's Exact test, P = 0.001). The median number of contacts was 2 (interquartile range = 1-3). There was no significant association between the number of contacts and SIMD decile. Forty-eight point one per cent (n = 261) of all contacts were with patients living in the most deprived decile and 88.6% (n = 481) in the most deprived 5 deciles. This was significantly more than expected compared with general population data (Fisher's Exact test, P = 0.008 and Fisher's Exact test, P ≤ 0.001). In the area under study, contact with ID psychiatry was greater in more deprived areas. Given the high psychiatric morbidity of people with ID, if services do not adjust for deprivation, this may lead to further discrimination in an already disadvantaged population. © 2014 MENCAP and International Association of the Scientific Study of Intellectual

  3. 97. Cumberland knob recreation area. The visitor contact center originally ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    97. Cumberland knob recreation area. The visitor contact center originally opened in 1941 as a combined sandwich shop, picnic area, and comfort station, the central building of the first recreation area to open looking north. - Blue Ridge Parkway, Between Shenandoah National Park & Great Smoky Mountains, Asheville, Buncombe County, NC

  4. Object Occlusion Detection Using Automatic Camera Calibration for a Wide-Area Video Surveillance System

    PubMed Central

    Jung, Jaehoon; Yoon, Inhye; Paik, Joonki

    2016-01-01

    This paper presents an object occlusion detection algorithm using object depth information that is estimated by automatic camera calibration. The object occlusion problem is a major factor to degrade the performance of object tracking and recognition. To detect an object occlusion, the proposed algorithm consists of three steps: (i) automatic camera calibration using both moving objects and a background structure; (ii) object depth estimation; and (iii) detection of occluded regions. The proposed algorithm estimates the depth of the object without extra sensors but with a generic red, green and blue (RGB) camera. As a result, the proposed algorithm can be applied to improve the performance of object tracking and object recognition algorithms for video surveillance systems. PMID:27347978

  5. Binding Direction-Based Two-Dimensional Flattened Contact Area Computing Algorithm for Protein-Protein Interactions.

    PubMed

    Kang, Beom Sik; Pugalendhi, GaneshKumar; Kim, Ku-Jin

    2017-10-13

    Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.

  6. Varying face occlusion detection and iterative recovery for face recognition

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Hu, Zhengping; Sun, Zhe; Zhao, Shuhuan; Sun, Mei

    2017-05-01

    In most sparse representation methods for face recognition (FR), occlusion problems were usually solved via removing the occlusion part of both query samples and training samples to perform the recognition process. This practice ignores the global feature of facial image and may lead to unsatisfactory results due to the limitation of local features. Considering the aforementioned drawback, we propose a method called varying occlusion detection and iterative recovery for FR. The main contributions of our method are as follows: (1) to detect an accurate occlusion area of facial images, an image processing and intersection-based clustering combination method is used for occlusion FR; (2) according to an accurate occlusion map, the new integrated facial images are recovered iteratively and put into a recognition process; and (3) the effectiveness on recognition accuracy of our method is verified by comparing it with three typical occlusion map detection methods. Experiments show that the proposed method has a highly accurate detection and recovery performance and that it outperforms several similar state-of-the-art methods against partial contiguous occlusion.

  7. Clinical measurement of the height of the interproximal contact area in maxillary anterior teeth.

    PubMed

    Sghaireen, Mohd G; Al-Zarea, Bader K; Al-Shorman, Hisham M; Al-Omiri, Mahmoud K

    2013-11-01

    To clinically quantify the apicoincisal height of interproximal areas directly in patients' mouths. Thirty participants (11 females and 9 males, mean age=26±1.5 years) were recruited into this study. Measurement of interproximal contact areas was carried out directly in patients' mouths using digital caliper (TERENSA, USA) with measuring accuracy of 0.01 mm. The interproximal contact areas that were measured are: central incisor to central incisor, central incisor to lateral incisor, lateral incisor to canine, and canine to first premolar on both sides of the jaw. Statistical significance was based on probability values less than 0.05 (p<0.05). The largest contact point was the one present between central incisors and it ranged from 2.9 to 6.5 mm. On the other hand, the contact point between canine and first premolar was the smallest on both sides of the arch and ranged from 0.6 to 2.5 mm. The dimensions of the contact points declined as we move from anterior area backwards. Statistical analysis using t-test showed that there were significant differences between the measurements of interproximal points of each tooth (P<0.05). the apicogingival dimension of the contact point decreased as we moved from anterior to posterior teeth. The contact area between the central incisors was largest and the one between canine and premolar was the smallest. This study is the first to report direct intra-oral clinical measurement of contact points. Clinical evaluation of contact point dimensions using digital caliber is a viable, quick and accurate method to use.

  8. Analysis of main parameters affecting substrate/mortar contact area through tridimensional laser scanner.

    PubMed

    Stolz, Carina M; Masuero, Angela B

    2015-10-01

    This study assesses the influence of the granulometric composition of sand, application energy and the superficial tension of substrates on the contact area of rendering mortars. Three substrates with distinct wetting behaviors were selected and mortars were prepared with different sand compositions. Characterization tests were performed on fresh and hardened mortars, as well as the rheological characterization. Mortars were applied to substrates with two different energies. The interfacial area was then digitized with 3D scanner. Results show that variables are all of influence on the interfacial contact in the development area. Furthermore, 3D laser scanning proved to be a good method to contact area measurement. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Effect of occlusal vertical dimension on lip positions at smile.

    PubMed

    Chou, Jang-Ching; Thompson, Geoffrey A; Aggarwal, Harshit A; Bosio, Jose A; Irelan, Jon P

    2014-09-01

    In complete mouth reconstructive dentistry, the occlusal vertical dimension may be increased to provide adequate restorative space or to improve esthetics. The effect of increasing the occlusal vertical dimension on the smile is not well understood. The purpose of this study was to evaluate the effect of increasing the occlusal vertical dimension on the dimensions of the smile. Thirty dental students, 12 men and 18 women between the ages of 21 and 30 years old, participated in this study. Polyvinyl siloxane occlusal registrations 2, 4, 6, and 8 mm in thickness were fabricated from articulated stone casts. Posed smile images at occlusal vertical dimension +0, +2, +4, +6, and +8 mm were made with a digital single lens reflex camera mounted on a tripod. A wall-mounted head-positioning device, modified from a cephalometric unit, was used to stabilize the head position. Interlabial gap height, intercommissural width, incisal edge to upper lip, and incisal edge-to-lower lip measurements were made with computer software. The smile index was obtained by dividing width by height. The display zone area was measured by using computer software tracing. One-way repeated measures ANOVA (α=.05) was used for statistical analysis. With an increase in the occlusal vertical dimension, the interlabial gap height, incisal edge to lower lip distance, and display zone area increased significantly (P<.001), whereas the smile index decreased significantly (P<.001). No significant changes were observed in the intercommissural width and incisal edge to upper lip distance. The interlabial gap height, incisal edge-to-lower lip distance, and display zone area increase with increased occlusal vertical dimension. The smile index decreases with increased occlusal vertical dimension. However, the width of the smile and the length of the upper lip tend to remain unchanged. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights

  10. Opening wedge trapezial osteotomy as possible treatment for early trapeziometacarpal osteoarthritis: a biomechanical investigation of radial subluxation, contact area, and contact pressure.

    PubMed

    Cheema, Tahseen; Salas, Christina; Morrell, Nathan; Lansing, Letitia; Reda Taha, Mahmoud M; Mercer, Deana

    2012-04-01

    Radial subluxation and cartilage thinning have been associated with initiation and accelerated development of osteoarthritis of the trapeziometacarpal joint. Few investigators have reported on the benefits of opening wedge trapezial osteotomy for altering the contact mechanics of the trapeziometacarpal joint as a possible deterrent to the initiation or progression of osteoarthritis. We used cadaveric specimens to determine whether opening wedge osteotomy of the trapezium was successful in reducing radial subluxation of the metacarpal base and to quantify the contact area and pressure on the trapezial surface during simulated lateral pinch. We used 8 fresh-frozen specimens in this study. The flexor pollicis longus, abductor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis brevis/opponens pollicis tendons were each loaded to simulate the thumb in lateral pinch position. We measured radial subluxation from anteroposterior radiographs before and after placement of a 15° wedge. We used real-time sensors to analyze contact pressure and contact area distribution on the trapezium. Center of force in the normal joint under lateral pinch loading was primarily located in the dorsal region of the trapezium. After wedge placement, contact pressure increased in the ulnar-dorsal region by 76%. Mean contact area increased in the ulnar-dorsal region from 0.05 to 0.07 cm(2), and in the ulnar-volar region from 0.003 to 0.024 cm(2). The average reduction in joint subluxation was 64%. The 15° opening wedge osteotomy of the trapezium reduced radial subluxation of the metacarpal on the trapezium and increased contact pressure and contact area away from the diseased compartments of the trapezial surface. Trapezial osteotomy addresses the 2 preeminent theories about the initiation and progression of osteoarthritis. By reducing radial subluxation and altering contact pressure and contact area, trapezial osteotomy may prove an alternative to first

  11. Evolution of real contact area under shear and the value of static friction of soft materials.

    PubMed

    Sahli, R; Pallares, G; Ducottet, C; Ben Ali, I E; Al Akhrass, S; Guibert, M; Scheibert, J

    2018-01-16

    The frictional properties of a rough contact interface are controlled by its area of real contact, the dynamical variations of which underlie our modern understanding of the ubiquitous rate-and-state friction law. In particular, the real contact area is proportional to the normal load, slowly increases at rest through aging, and drops at slip inception. Here, through direct measurements on various contacts involving elastomers or human fingertips, we show that the real contact area also decreases under shear, with reductions as large as 30[Formula: see text], starting well before macroscopic sliding. All data are captured by a single reduction law enabling excellent predictions of the static friction force. In elastomers, the area-reduction rate of individual contacts obeys a scaling law valid from micrometer-sized junctions in rough contacts to millimeter-sized smooth sphere/plane contacts. For the class of soft materials used here, our results should motivate first-order improvements of current contact mechanics models and prompt reinterpretation of the rate-and-state parameters.

  12. Effect of radial head implant shape on joint contact area and location during static loading.

    PubMed

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. The influence of altered working-side occlusal guidance on masticatory muscles and related jaw movement.

    PubMed

    Belser, U C; Hannam, A G

    1985-03-01

    The effect of four different occlusal situations (group function, canine guidance, working side occlusal interference, and hyperbalancing occlusal interference) on EMG activity in jaw elevator muscles and related mandibular movement was investigated on 12 subjects. With a computer-based system, EMG and displacement signals were collected simultaneously during specific functional (unilateral chewing) and parafunctional tasks (mandibular gliding movements and various tooth clenching efforts) and analyzed quantitatively. When a naturally acquired group function was temporarily and artificially changed into a dominant canine guidance, a significant general reduction of elevator muscle activity was observed when subjects exerted full isometric tooth-clenching efforts in a lateral mandibular position. The original muscular coordination pattern (relative contraction from muscle to muscle) remained unaltered during this test. With respect to unilateral chewing, no significant alterations in the activity or coordination of the muscles occurred when an artificial canine guidance was introduced. Introduction of a hyperbalancing occlusal contact caused significant alterations in muscle activity and coordination during maximal tooth clenching in a lateral mandibular position. A marked shift of temporal muscle EMG activity toward the side of the interference and unchanged bilateral activity of the two masseter muscles were observed. The results suggest that canine-protected occlusions do not significantly alter muscle activity during mastication but significantly reduce muscle activity during parafunctional clenching. They also suggest that non-working side contacts dramatically alter the distribution of muscle activity during parafunctional clenching, and that this redistribution may affect the nature of reaction forces at the temporomandibular joints.

  14. Evolution of the Contact Area with Normal Load for Rough Surfaces: from Atomic to Macroscopic Scales.

    PubMed

    Huang, Shiping

    2017-11-13

    The evolution of the contact area with normal load for rough surfaces has great fundamental and practical importance, ranging from earthquake dynamics to machine wear. This work bridges the gap between the atomic scale and the macroscopic scale for normal contact behavior. The real contact area, which is formed by a large ensemble of discrete contacts (clusters), is proven to be much smaller than the apparent surface area. The distribution of the discrete contact clusters and the interaction between them are key to revealing the mechanism of the contacting solids. To this end, Green's function molecular dynamics (GFMD) is used to study both how the contact cluster evolves from the atomic scale to the macroscopic scale and the interaction between clusters. It is found that the interaction between clusters has a strong effect on their formation. The formation and distribution of the contact clusters is far more complicated than that predicted by the asperity model. Ignorance of the interaction between them leads to overestimating the contacting force. In real contact, contacting clusters are smaller and more discrete due to the interaction between the asperities. Understanding the exact nature of the contact area with the normal load is essential to the following research on friction.

  15. Evolution of the Contact Area with Normal Load for Rough Surfaces: from Atomic to Macroscopic Scales

    NASA Astrophysics Data System (ADS)

    Huang, Shiping

    2017-11-01

    The evolution of the contact area with normal load for rough surfaces has great fundamental and practical importance, ranging from earthquake dynamics to machine wear. This work bridges the gap between the atomic scale and the macroscopic scale for normal contact behavior. The real contact area, which is formed by a large ensemble of discrete contacts (clusters), is proven to be much smaller than the apparent surface area. The distribution of the discrete contact clusters and the interaction between them are key to revealing the mechanism of the contacting solids. To this end, Green's function molecular dynamics (GFMD) is used to study both how the contact cluster evolves from the atomic scale to the macroscopic scale and the interaction between clusters. It is found that the interaction between clusters has a strong effect on their formation. The formation and distribution of the contact clusters is far more complicated than that predicted by the asperity model. Ignorance of the interaction between them leads to overestimating the contacting force. In real contact, contacting clusters are smaller and more discrete due to the interaction between the asperities. Understanding the exact nature of the contact area with the normal load is essential to the following research on friction.

  16. Activity-dependent decrease in contact areas between subsurface cisterns and plasma membrane of hippocampal neurons.

    PubMed

    Tao-Cheng, Jung-Hwa

    2018-04-16

    Subsurface cistern (SSC) in neuronal soma and primary dendrites is a specialized compartment of endoplasmic reticulum (ER) that is in close apposition (10 nm) with the plasma membrane (PM). ER-PM contact areas are thought to be involved in intracellular calcium regulation. Here, structural changes of SSC in hippocampal neurons were examined by electron microscopy upon depolarization with high K + (90 mM) or application of NMDA (50 μM) in rat dissociated cultures as well as organotypic slice cultures. The number and average length of SSC-PM contact areas in neuronal somas significantly decreased within 30 s under excitatory condition. This decrease in SSC-PM contact area progressed with time and was reversible. These results demonstrate a structural decoupling between the SSC and the PM upon stimulation, suggesting that there may be a functional decoupling of the calcium regulation. Because SSC-PM contact areas may mediate calcium influx, the decrease in contact area may protect neurons from calcium overload upon heightened stimulation.

  17. Tibiofemoral joint contact area and pressure after single- and double-bundle anterior cruciate ligament reconstruction.

    PubMed

    Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H

    2009-01-01

    The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.

  18. OCT aspects of dental hard tissue changes induced by excessive occlusal forces

    NASA Astrophysics Data System (ADS)

    Scrieciu, Monica; Mercuţ, Veronica; Popescu, Sanda Mihaela; Tǎrâţǎ, Daniela; Osiac, Eugen

    2018-03-01

    The study purpose is to highlight dental hard tissues changes of a tooth with dental wear as a consequence of excessive occlusal forces, using OCT. Methods: a central incisor extracted for periodontal reason was cleaned and it was embedded in a black acrylic resin block. The block was sectioned along the longitudinal axis of the tooth and prepared for OCT analysis. Results: The OCT signal showed differences between the labial and palatal dental hard tissue structures, even in areas without excessive occlusal solicitations. Conclusion: The OCT signal highlights changes of dental hard tissues structures according to excessive occlusal solicitations areas.

  19. Contact area of rough spheres: Large scale simulations and simple scaling laws

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pastewka, Lars, E-mail: lars.pastewka@kit.edu; Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218; Robbins, Mark O., E-mail: mr@pha.jhu.edu

    2016-05-30

    We use molecular simulations to study the nonadhesive and adhesive atomic-scale contact of rough spheres with radii ranging from nanometers to micrometers over more than ten orders of magnitude in applied normal load. At the lowest loads, the interfacial mechanics is governed by the contact mechanics of the first asperity that touches. The dependence of contact area on normal force becomes linear at intermediate loads and crosses over to Hertzian at the largest loads. By combining theories for the limiting cases of nominally flat rough surfaces and smooth spheres, we provide parameter-free analytical expressions for contact area over the wholemore » range of loads. Our results establish a range of validity for common approximations that neglect curvature or roughness in modeling objects on scales from atomic force microscope tips to ball bearings.« less

  20. [Clinical evaluation of preadjusted appliance based on Chinese normal occlusion].

    PubMed

    Chen, Lin; Gao, Xue-Mei; Zeng, Xiang-Long

    2008-02-01

    To evaluate the effect of the preadjusted appliance (Z1 appliance) based on Chinese normal occlusion. Thirty non-extraction patients were treated with Z1 appliance. No wire bending was made during treatment. The results of these 30 cases had been evaluated by five senior orthodontists. Models were analysed quantitatively to testify and evaluate the efficiency of the appliance. The average score for post-treatment models was 91.2 (total score was 100). The model measurements indicated that average projective distance on occlusal plane between proximal contact points of adjacent teeth was less than 0.3 mm, which demonstrated good alignment. The prominence of crowns was almost coincident with the data of Chinese normal occlusion. For the average tip of most teeth, there was no statistical difference between the study group and the normal control group. The crown torque variation tendency from anterior to posterior was similar to that in the subjects with normal occlusion. However, the cases treated with Z1 appliance achieved more negative torque in the lower posterior segment. The result of the non-extraction patients treated with Z1 appliance was quite satisfied. Wire bending could be reduced during treatment. It was necessary to adjust the crown torque values for lower posterior teeth.

  1. [Integrated therapeutic strategy in large bowel neoplastic occlusion. An innovative therapeutic protocol].

    PubMed

    Gattai, Riccardo; Mascitelli, Erminia Macera; Bechi, Paolo; Pace, Marcello

    2007-01-01

    Occlusive complication is a common event in the colo-rectal cancer (20-30% of cases). Operative mortality and 5 yrs survival of not occlusive cancer vs occlusive cancer is 11% vs 23% and 45% vs 25% rispectively. In occlusive cancer the level of parietal infiltration affects considerably the local and peritoneal recurrence. 50% of all patients underwent a surgical re-operation for colo-rectal cancer have peritoneal neoplastic implant. The resolution of occlusive complication in immediate or delayed urgency with decompressive derivation, it allows to perform an integrated treatment of choice that it could guarantee the oncological radical procedure. RATIONALE-METHODS: The intraperitoneal hyperthermic chemotherapy (IPHC) combined with radical or cytoriductive surgery performs its action through sinergistic effects of high dosage and concentration of drugs and hyperthermia. These agents perform a cell killing with a direct contact against micro and/or macroscopic neoplastic residue. In radical surgery with curative intent, the association with IPHC ("preventive" adjuvant) has got as objective the distruction of microscopic local or peritoneal metastasis. In occlusive cancer with synchronous or metachronous peritoneal carcinomatosis, the performance of the cytoreductive surgery with IPHC ("therapeutic" adjuvant) is the only treatment that improves the survival and the quality of remainig life. The clinical results reported by many Istitutions indicates that the 2-5 yrs survivals are 45-60% and 20-30% rispectively. These data lead us to believe that an optimal eradication of micro and/or macroscopic peritoneal spreading could be optained also in occlusive colo-rectal cancer.

  2. Occlusal traits of deciduous dentition of preschool children of Indian children

    PubMed Central

    Bahadure, Rakesh N.; Thosar, Nilima; Gaikwad, Rahul

    2012-01-01

    Objectives: To assess the occlusal relationship, canine relationship, crowding, primate spaces, and anterior spacing in both maxillary and mandibular arches of primary dentition of Indian children of Wardha District and also to study the age-wise differences in occlusal characteristics. Materials and Methods: A total of 1053 (609 males and 444 females) children of 3-5 year age group with complete primary dentition were examined for occlusal relationship, canine relationship, crowding, primate spaces, and anterior spacing in both maxillary and mandibular arches. Results: The data after evaluation showed significant values for all parameters except mandibular anterior spacing, which was 47.6%. Mild crowding was prevalent at 5 year age group and moderate crowding was common at 3 year-age group. Conclusion: Evaluated parameters such as terminal molar relationship and canine relationship were predominantly progressing toward to normal but contacts and crowding status were contributing almost equal to physiologic anterior spacing. Five-year-age group showed higher values with respect to all the parameters. PMID:23633806

  3. Occlusal status and prevalence of occlusal malocclusion traits among 9-year-old schoolchildren.

    PubMed

    Lux, Christopher J; Dücker, Britta; Pritsch, Maria; Komposch, Gerda; Niekusch, Uwe

    2009-06-01

    The aim of this study was to provide detailed information concerning clinically relevant occlusal traits and the prevalence of occlusal anomalies in an orthodontically relevant period of dental development. Four hundred and ninety-four German schoolchildren (237 males and 257 females), median age 9 years, were orthodontically examined. Overjet and overbite were measured to the nearest 0.5 mm, and sagittal molar relationships were registered clinically to the nearest quarter unit. In addition, crossbites, scissor bites, and midline displacements were evaluated. Descriptive statistics was complemented by testing gender differences and differences between groups with Class I and Class II anomalies (Mann-Whitney U-test) as well as a statistical evaluation of differences between the three dental stages (Kruskal-Wallis test). Overjet exhibited an extreme range between -2 and 12 mm (median values 3-3.5 mm). An increased overjet was more prevalent than a reduced or reverse overjet, and a severely increased overjet greater than 6 mm was a common finding affecting around 5-10 per cent of the children. Similarly, overbite showed considerable variations of between -1 and 9 mm (medians 3-3.5 mm) and males exhibited a significantly larger overbite than females. In Class II malocclusion subjects, overbite was significantly enlarged (on average between 0.5 and 1 mm) when compared with those with a Class I malocclusion. Traumatic contact of the gingiva affected every 14th child. A Class II molar relationship of three-quarter units or more was a frequent finding affecting more than one child in five. In addition, at 9 years of age, 3 per cent of the children exhibited a Class III molar relationship of at least a half unit. The wide range of orthodontically relevant occlusal traits found in the present study underlines the need for orthodontic screening at 9 years of age (or earlier).

  4. Conductive contact area estimation for carbon nanotube via interconnects using secondary-electron imaging

    NASA Astrophysics Data System (ADS)

    Abe, Yusuke; Suzuki, Makoto; Vyas, Anshul; Yang, Cary Y.

    2018-01-01

    A major challenge for carbon nanotube (CNT) to become a viable replacement of copper and tungsten in the next-generation on-chip via interconnects is the high contact resistance between CNT and metal electrodes. A first step in meeting this challenge is an accurate characterization of via contact resistance. In this paper, the scanning electron microscope (SEM) image contrast at low landing energy is employed to estimate the conductive CNT area inside vias. The total conductive CNT area inside each via is deduced using SEM image with 0.1 keV landing energy and a specified threshold brightness, yielding via resistance versus CNT area behavior, which correlates well with electrical nanoprobing measurements of via resistance. Monte Carlo simulation of secondary electron generation lends further support for our analysis and suggests that the residue covering the CNT does not affect the conduction across the contact for residue thickness below 1 nm. This imaging and analysis technique can add much value to CNT via interconnect contact characterization.

  5. Time Dependent Frictional Changes in Ice due to Contact Area Changes

    NASA Astrophysics Data System (ADS)

    Sevostianov, V.; Lipovsky, B. P.; Rubinstein, S.; Dillavou, S.

    2017-12-01

    Sliding processes along the ice-bed interface of Earth's great ice sheets are the largest contributor to our uncertainty in future sea level rise. Laboratory experiments that have probed sliding processes have ubiquitously shown that ice-rock interfaces strengthen while in stationary contact (Schulson and Fortt, 2013; Zoet et al., 2013; McCarthy et al., 2017). This so-called frictional ageing effect may have profound consequences for ice sheet dynamics because it introduces the possibility of basal strength hysteresis. Furthermore this effect is quite strong in ice-rock interfaces (more than an order of magnitude more pronounced than in rock-rock sliding) and can double in frictional strength in a matter of minutes, much faster than most frictional aging (Dieterich, 1972; Baumberger and Caroli, 2006). Despite this importance, the underling physics of frictional ageing of ice remain poorly understood. Here we conduct laboratory experiments to image the microscopic points of contact along an ice-glass interface. We optically measure changes in the real area of contact over time using measurements of this reflected optical light intensity. We show that contact area increases with time of stationary contact. This result suggests that thermally enhanced creep of microscopic icy contacts is responsible for the much larger frictional ageing observed in ice-rock versus rock-rock interfaces. Furthermore, this supports a more physically detailed description of the thermal dependence of basal sliding than that used in the current generation of large scale ice sheet models.

  6. In vivo tibiofemoral cartilage-to-cartilage contact area of females with medial osteoarthritis under acute loading using MRI.

    PubMed

    Shin, Choongsoo S; Souza, Richard B; Kumar, Deepak; Link, Thomas M; Wyman, Bradley T; Majumdar, Sharmila

    2011-12-01

    To investigate the effect of acute loading on in vivo tibiofemoral contact area changes in both compartments, and to determine whether in vivo tibiofemoral contact area differs between subjects with medial knee osteoarthritis (OA) and healthy controls. Ten subjects with medial knee OA (KL3) and 11 control subjects (KL0) were tested. Coronal three-dimensional spoiled gradient-recalled (3D-SPGR) and T(2) -weighted fast spin-echo FSE magnetic resonance imaging (MRI) of the knee were acquired under both unloaded and loaded conditions. Tibiofemoral cartilage contact areas were measured using image-based 3D models. Tibiofemoral contact areas in both compartments significantly increased under loading (P < 0.001) and the increased contact area in the medial compartment was significantly larger than in the lateral compartment (P < 0.05). Medial compartment contact area was significantly larger in KL3 subjects than KL0 subjects, both at unloaded and loaded conditions (P < 0.05). Contact areas measured from 3D-SPGR and T(2) -weighted FSE images were strongly correlated (r = 0.904). Females with medial OA increased tibiofemoral contact area in the medial compartment compared to healthy subjects under both unloaded and loaded conditions. The contact area data presented in this study may provide a quantitative reference for further cartilage contact biomechanics such as contact stress analysis and cartilage biomechanical function difference between osteoarthritic and healthy knees. Copyright © 2011 Wiley Periodicals, Inc.

  7. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    PubMed

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  8. Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.

    PubMed

    Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D

    2011-10-01

    To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.

  9. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    PubMed

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  10. Comparison of MRI-based estimates of articular cartilage contact area in the tibiofemoral joint.

    PubMed

    Henderson, Christopher E; Higginson, Jill S; Barrance, Peter J

    2011-01-01

    Knee osteoarthritis (OA) detrimentally impacts the lives of millions of older Americans through pain and decreased functional ability. Unfortunately, the pathomechanics and associated deviations from joint homeostasis that OA patients experience are not well understood. Alterations in mechanical stress in the knee joint may play an essential role in OA; however, existing literature in this area is limited. The purpose of this study was to evaluate the ability of an existing magnetic resonance imaging (MRI)-based modeling method to estimate articular cartilage contact area in vivo. Imaging data of both knees were collected on a single subject with no history of knee pathology at three knee flexion angles. Intra-observer reliability and sensitivity studies were also performed to determine the role of operator-influenced elements of the data processing on the results. The method's articular cartilage contact area estimates were compared with existing contact area estimates in the literature. The method demonstrated an intra-observer reliability of 0.95 when assessed using Pearson's correlation coefficient and was found to be most sensitive to changes in the cartilage tracings on the peripheries of the compartment. The articular cartilage contact area estimates at full extension were similar to those reported in the literature. The relationships between tibiofemoral articular cartilage contact area and knee flexion were also qualitatively and quantitatively similar to those previously reported. The MRI-based knee modeling method was found to have high intra-observer reliability, sensitivity to peripheral articular cartilage tracings, and agreeability with previous investigations when using data from a single healthy adult. Future studies will implement this modeling method to investigate the role that mechanical stress may play in progression of knee OA through estimation of articular cartilage contact area.

  11. Relationship Between the Electroglottographic Signal and Vocal Fold Contact Area.

    PubMed

    Hampala, Vít; Garcia, Maxime; Švec, Jan G; Scherer, Ronald C; Herbst, Christian T

    2016-03-01

    Electroglottography (EGG) is a widely used noninvasive method that purports to measure changes in relative vocal fold contact area (VFCA) during phonation. Despite its broad application, the putative direct relation between the EGG waveform and VFCA has to date only been formally tested in a single study, suggesting an approximately linear relationship. However, in that study, flow-induced vocal fold (VF) vibration was not investigated. A rigorous empirical evaluation of EGG as a measure of VFCA under proper physiological conditions is therefore still needed. Three red deer larynges were phonated in an excised hemilarynx preparation using a conducting glass plate. The time-varying contact between the VF and the glass plate was assessed by high-speed video recordings at 6000 fps, synchronized to the EGG signal. The average differences between the normalized [0, 1] VFCA and EGG waveforms for the three larynges were 0.180 (±0.156), 0.075 (±0.115), and 0.168 (±0.184) in the contacting phase and 0.159 (±0.112), -0.003 (±0.029), and 0.004 (±0.032) in the decontacting phase. Overall, there was a better agreement between VFCA and the EGG waveform in the decontacting phase than in the contacting phase. Disagreements may be caused by nonuniform tissue conductance properties, electrode placement, and electroglottograph hardware circuitry. Pending further research, the EGG waveform may be a reasonable first approximation to change in medial contact area between the VFs during phonation. However, any quantitative and statistical data derived from EGG should be interpreted cautiously, allowing for potential deviations from true VFCA. Copyright © 2016 The Auhors. Published by Elsevier Inc. All rights reserved.

  12. Technique eliminates high voltage arcing at electrode-insulator contact area

    NASA Technical Reports Server (NTRS)

    Mealy, G.

    1967-01-01

    Coating the electrode-insulator contact area with silver epoxy conductive paint and forcing the electrode and insulator tightly together into a permanent connection, eliminates electrical arcing in high-voltage electrodes supplying electrical power to vacuum facilities.

  13. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    PubMed

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  14. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses

    PubMed Central

    Witt, Florian; Gührs, Julian; Morlock, Michael M.; Bishop, Nicholas E.

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface. PMID:26280914

  15. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    PubMed

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  16. Longitudinal analysis of tibiofemoral cartilage contact area and position in ACL reconstructed patients.

    PubMed

    Chen, Ellison; Amano, Keiko; Pedoia, Valentina; Souza, Richard B; Ma, C Benjamin; Li, Xiaojuan

    2018-04-18

    Patients who have suffered ACL injury are more likely to develop early onset post-traumatic osteoarthritis despite reconstruction. The purpose of our study was to evaluate the longitudinal changes in the tibiofemoral cartilage contact area size and location after ACL injury and reconstruction. Thirty-one patients with isolated unilateral ACL injury were followed with T 2 weighted Fast Spin Echo, T 1ρ and T 2 MRI at baseline prior to reconstruction, and 6 months, 1 year, and 2 years after surgery. Areas were delineated in FSE images with an in-house Matlab program using a spline-based semi-automated segmentation algorithm. Tibiofemoral contact area and centroid position along the anterior-posterior axis were calculated along with T 1ρ and T 2 relaxation times on both the injured and non-injured knees. At baseline, the injured knees had significantly smaller and more posteriorly positioned contact areas on the medial tibial surface compared to corresponding healthy knees. These differences persisted 6 months after reconstruction. Moreover, subjects with more anterior medial centroid positions at 6 months had elevated T 1ρ and T 2 measures in the posterior medial tibial plateau at 1 year. Changes in contact area and centroid position after ACL injury and reconstruction may characterize some of the mechanical factors contributing to post-traumatic osteoarthritis. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Tongue Palate Contact Patterns of Velar Stops in Normal Adult English Speakers

    ERIC Educational Resources Information Center

    Liker, Marko; Gibbon, Fiona E.

    2008-01-01

    This paper provides a more detailed description of normal tongue palate contact patterns for the occlusion phase of velar stops than currently exists. The study used electropalatography (EPG) to record seven normally speaking adults' contact patterns of voiceless velar stops in nine VkV contexts. A variety of EPG indices measured: per cent…

  18. CEREC Chairside System to Register and Design the Occlusion in Restorative Dentistry: A Systematic Literature Review.

    PubMed

    Bohner, Lauren Oliveira Lima; Neto, Pedro Tortamano; Ahmed, Ahad Shahid; Mori, Matsuyoshi; Laganá, Dalva Cruz; Sesma, Newton

    2016-07-01

    The aim of this review was to update the literature with regard to the digital methods available by CEREC Chairside system to register and design the occlusion, to report their efficacy and technical innovations in the field of Restorative Dentistry. A search strategy was performed using the key-words: "virtual articulator," or "CAD-CAM and occlusal recording," or "CAD-CAM and occlusion register," or "CAD-CAM and occlusal contacts," or "CAD-CAM and prosthesis." Inclusion criteria comprised studies evaluating the use of digital methods available by CEREC System for occlusal registration and design during prosthodontics treatment. PubMed and Cochrane library and reference lists were searched up to January 2016. The search resulted in 280 articles after removing duplicates. Subsequently, 233 records were excluded and 49 studies were selected for reading in full. Eleven articles were considered eligible for the systematic review (4 in vitro and 7 clinical studies). Scientific evidence suggests that digital methods were accurate to register and design the occlusion of dental prostheses. Nevertheless, further clinical studies are required to establish a conclusion with regard to its accuracy in prosthodontics treatment. Digital technologies allow the design of occlusal surfaces of CAD-CAM fabricated prostheses using innovative approaches. This systematic review aimed to update the literature to help dentists determine the most appropriate digital method to register and design the occlusal surface of CAD-CAM crowns. (J Esthet Restor Dent 28:208-220, 2016). © 2016 Wiley Periodicals, Inc.

  19. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    PubMed

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  20. A Mathematical Method to Calculate Tumor Contact Surface Area: An Effective Parameter to Predict Renal Function after Partial Nephrectomy.

    PubMed

    Hsieh, Po-Fan; Wang, Yu-De; Huang, Chi-Ping; Wu, Hsi-Chin; Yang, Che-Rei; Chen, Guang-Heng; Chang, Chao-Hsiang

    2016-07-01

    We proposed a mathematical formula to calculate contact surface area between a tumor and renal parenchyma. We examined the applicability of using contact surface area to predict renal function after partial nephrectomy. We performed this retrospective study in patients who underwent partial nephrectomy between January 2012 and December 2014. Based on abdominopelvic computerized tomography or magnetic resonance imaging, we calculated the contact surface area using the formula (2*π*radius*depth) developed by integral calculus. We then evaluated the correlation between contact surface area and perioperative parameters, and compared contact surface area and R.E.N.A.L. (Radius/Exophytic/endophytic/Nearness to collecting system/Anterior/Location) score in predicting a reduction in renal function. Overall 35, 26 and 45 patients underwent partial nephrectomy with open, laparoscopic and robotic approaches, respectively. Mean ± SD contact surface area was 30.7±26.1 cm(2) and median (IQR) R.E.N.A.L. score was 7 (2.25). Spearman correlation analysis showed that contact surface area was significantly associated with estimated blood loss (p=0.04), operative time (p=0.04) and percent change in estimated glomerular filtration rate (p <0.001). On multivariate analysis contact surface area and R.E.N.A.L. score independently affected percent change in estimated glomerular filtration rate (p <0.001 and p=0.03, respectively). On ROC curve analysis contact surface area was a better independent predictor of a greater than 10% change in estimated glomerular filtration rate compared to R.E.N.A.L. score (AUC 0.86 vs 0.69). Using this simple mathematical method, contact surface area was associated with surgical outcomes. Compared to R.E.N.A.L. score, contact surface area was a better predictor of functional change after partial nephrectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Numeric simulation of occlusal interferences in molars restored with ultrathin occlusal veneers.

    PubMed

    Magne, Pascal; Cheung, Raymond

    2017-01-01

    Selecting material for a minimally invasive occlusal veneer reconstruction concept requires an understanding of how stresses are distributed during functional and parafunctional forces. The purpose of this in vitro study was to investigate stress distribution in a maxillary molar restored with ultrathin occlusal veneers and subjected by an antagonistic mandibular molar to clenching and working and nonworking movements. A maxillary first molar was modeled from microcomputed tomography (micro-CT) data, using medical image processing software, stereolithography editing/optimizing software, and finite element software. Simulated ultrathin occlusal veneer materials were used. The mandibular molar antagonist was a solid nondeformable geometric entity. Loads simulated clenching, working, and nonworking movements with loading of 500 N. The values of the maximum principal stress were recorded. In the clenching load situation, maximum tensile stresses were located at the occlusal veneer (52 MPa for composite resin versus 47 MPa for ceramic). In the working movement, significant additional tensile stresses were found on the palatal root (87 MPa for composite resin and 85 MPa for ceramic). In the nonworking movement, tensile stress on the ultrathin occlusal veneer increased to 118 MPa for composite resin and 143 MPa for ceramic veneers. Tensile stress peaks shifted to the mesiobuccal root (75 MPa for composite resin and 74 MPa for ceramic). The topography of stresses generated by the various occlusal interferences were clearly identified. Significant tensile stress concentrations were found within the restoration's occlusal topography and root, with the nonworking interference being the most harmful and also the most revealing of the difference between the composite resin and ceramic ultrathin occlusal veneers. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Effect of hoof angle on joint contact area in the equine metacarpophalangeal joint following simulated impact loading ex vivo.

    PubMed

    McCarty, C A; Thomason, J J; Gordon, K; Hurtig, M; Bignell, W

    2015-11-01

    To add to the existing data on impact loading of the metacarpophalangeal (MCP) joint as a precursor to assessing the potential role of impact in joint disease. To examine the effect of impact loading on contact areas of the first phalanx (P1) and proximal sesamoids (PS) with the third metacarpal (McIII) under 3 hoof-strike conditions (toe-first, flat, heel-first). Randomised, repeated controlled experiment using cadaver material. Eight cadaver limbs were subjected to randomised, repeated controlled trials where the hoof was struck by a pendulum impact machine (impact velocity 3.55 m/s) under 3 strike conditions. Data from pressure sensitive film placed over medial and lateral McIII condyles and lateromedially across the dorsal aspect of McIII were quantified: total areas of P1 and PS contact (cm(2) ) at maximum recorded pressure; centroid locations of contact areas relative to the sagittal ridge (cm) and transverse ridge (cm) and dispersion of pixels (cm(4) ) for each McIII condyle (medial/lateral). The effect of the strike conditions on each variable were statistically tested using repeated-measures ANOVA (α = 0.05). Contact area between P1 and McIII condyles fell in well-defined areas bounded by the sagittal and transverse ridge, contact areas from PS were smaller and widely dispersed across McIII palmar border. Ratio of contact area of P1 to PS was 2.83 (P<0001). Hoof strike had no significant effect on contact area (P>0.54) CONCLUSIONS: Contact at impact (primarily from P1 and distally situated on McIII), contrasts with contact areas at midstance from both P1 and PS, symmetrically placed. Under impact, the greatest contact area was on the dorsal aspect of the medial condyle and coincides with the area subjected to the greatest increase in subchondral bone stiffening in joint disease. © 2014 EVJ Ltd.

  3. The effects of oral appliance therapy on occlusal function in patients with obstructive sleep apnea: a short-term prospective study.

    PubMed

    Otsuka, Ryo; Almeida, Fernanda Ribeiro; Lowe, Alan A

    2007-02-01

    The aim of this study was to objectively and prospectively assess whether oral appliances (OAs) alter occlusal function in patients treated for snoring or obstructive sleep apnea. The occlusal contact area (OCA) and bite force (Bf) of 12 patients who used OAs were measured with pressure-sensitive sheets in the morning and evening with the Dental Prescale Occluzer System. OCA and Bf were compared in each measurement period by using ANOVA. Percentage changes in the morning relative to the evening (OCA(M-E) and Bf(M-E)) were compared between the 2 periods by using the Wilcoxon signed rank test. Correlations between percentage changes in pretreatment and posttitration ((Pre-Post)OCA and (Pre-Post)Bf), age, and cephalometric variables were also assessed. Patients showed significant decreases in OCA and Bf when posttitration readings were compared with corresponding pretreatment measurements. OCA(M-E) and Bf(M-E) were significantly different between pretreatment and posttitration, suggesting that OCA and Bf tend to be smaller in the morning with OA use. (Pre-Post)Bf measured in the evening correlated with age. Effects on occlusal function after OA use were observed. These results suggest that practitioners should pay attention to the possible side effects of OAs on the dentition when treating patients with snoring or obstructive sleep apnea.

  4. Prefrontal Hemodynamic Changes Associated with Subjective Sense of Occlusal Discomfort

    PubMed Central

    Kobayashi, Goh; Hayama, Rika; Ikuta, Ryuhei; Onozouka, Minoru; Wake, Hiroyuki; Shimada, Atsushi; Shibuya, Tomoaki; Tamaki, Katsushi

    2015-01-01

    We used functional near-infrared spectroscopy to measure prefrontal brain activity accompanying the physical sensation of oral discomfort that arose when healthy young-adult volunteers performed a grinding motion with mild occlusal elevation (96 μm). We simultaneously evaluated various forms of occlusal discomfort using the visual analogue scale (VAS) and hemodynamic responses to identify the specific prefrontal activity that occurs with increased occlusal discomfort. The Oxy-Hb responses of selected channels in the bilateral frontopolar and dorsolateral prefrontal cortices increased in participants who reported increased severity of occlusal discomfort, while they decreased in those who reported no change or decreased occlusal discomfort during grinding. Moreover, the cumulative values of Oxy-Hb response in some of these channels were statistically significant predictive factors for the VAS scores. A generalized linear model analysis of Oxy-Hb signals in a group of participants who reported increased discomfort further indicated significant cerebral activation in the right frontopolar and dorsolateral prefrontal cortices that overlapped with the results of correlation analyses. Our results suggest that the increased hemodynamic responses in the prefrontal area reflect the top-down control of attention and/or self-regulation against the uncomfortable somatosensory input, which could be a possible marker to detect the subjective sense of occlusal discomfort. PMID:26090407

  5. Laser targeted photo-occlusion of rat choroidal neovascularization without collateral damage.

    PubMed

    Nishiwaki, Hirokazu; Zeimer, Ran; Goldberg, Morton F; D'Anna, Salvatore A; Vinores, Stanley A; Grebe, Rhonda

    2002-02-01

    Laser targeted photo-occlusion (LTO) is a novel method being developed to treat choroidal neovascular membranes (CNV) in age-related and other macular degenerations. A photosensitive agent, encapsulated in heat-sensitive liposomes, is administered intravenously. A low power laser warms the targeted tissue and releases a bolus of photosensitizer. The photosensitizer is activated after it clears from the normal choriocapillaris but not from the CNV. Forty-five experimental CNV were induced in seven rats. Five weeks after LTO, complete occlusion was observed by laser targeted angiography (LTA) in 76% of treated CNV, and partial occlusion was found in the remaining 24%. The tissues outside the CNV but within the area treated by LTO showed no flow alteration and no dye leakage. All untreated CNV were patent on LTA at 5 weeks. Light microscopy and electron microscopy confirmed the results in treated and control lesions. Moreover, treated areas next to lesions showed normal photoreceptors, retinal pigment epithelium (RPE), Bruch's membrane and choriocapillaris. These results indicate that LTO may improve current photodynamic therapy by alleviating the need for repeated treatments and by avoiding the long-term risks associated with damage to the RPE and occlusion of normal choriocapillaries.

  6. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference.

    PubMed

    Ono, Yumie; Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-11-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near-infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task-related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task-related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD.

  7. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference

    PubMed Central

    Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-01-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near‐infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task‐related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task‐related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD. PMID:29744159

  8. The fraction of total hand surface area involved in young children's outdoor hand-to-object contacts.

    PubMed

    AuYeung, Willa; Canales, Robert A; Leckie, James O

    2008-11-01

    Information on the fraction of total hand surface area touching a contaminated object is necessary in accurately estimating contaminant (e.g., pesticides, pathogens) loadings onto the hands during hand-to-object contacts. While several existing physical-stochastic human exposure models require such surface area data to estimate dermal and non-dietary ingestion exposure, there are very limited data sets. This paper provides statistical distributions of fractional surface areas (FSAs) for children's outdoor hand contacts. These distributions were constructed by combining information collected from two distinct studies exploring children's activity patterns and quantifying hand contact surface area. Results show that for outdoor contacts with "All Objects", a range of 0.13-0.27 captured median FSAs, while a range of 0.12-0.24 captured time-weighted FSAs. Overall, an FSA of 0.31 captured 80-100% of FSAs involved in each child's outdoor hand contacts, depending upon the object of interest. These values are much lower than the often conservative assumptions of up to 1 (i.e., the entire hand) that researchers currently make regarding FSAs involved in indoor and outdoor contacts [USEPA, 1997. Standard operating procedures (SOPs) for residential exposure assessments. Contract no. 68-W6-0030. http://www.epa.gov/pesticides/trac/science/trac6a05.pdf].

  9. Occlusal enamel complexity in middle miocene to holocene equids (Equidae: Perissodactyla) of North America.

    PubMed

    Famoso, Nicholas A; Davis, Edward Byrd

    2014-01-01

    Four groups of equids, "Anchitheriinae," Merychippine-grade Equinae, Hipparionini, and Equini, coexisted in the middle Miocene, but only the Equini remains after 16 Myr of evolution and extinction. Each group is distinct in its occlusal enamel pattern. These patterns have been compared qualitatively but rarely quantitatively. The processes influencing the evolution of these occlusal patterns have not been thoroughly investigated with respect to phylogeny, tooth position, and climate through geologic time. We investigated Occlusal Enamel Index, a quantitative method for the analysis of the complexity of occlusal patterns. We used analyses of variance and an analysis of co-variance to test whether equid teeth increase resistive cutting area for food processing during mastication, as expressed in occlusal enamel complexity, in response to increased abrasion in their diet. Results suggest that occlusal enamel complexity was influenced by climate, phylogeny, and tooth position through time. Occlusal enamel complexity in middle Miocene to Modern horses increased as the animals experienced increased tooth abrasion and a cooling climate.

  10. Thigh-calf contact parameters for six high knee flexion postures: Onset, maximum angle, total force, contact area, and center of force.

    PubMed

    Kingston, David C; Acker, Stacey M

    2018-01-23

    In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm 2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Comparison of plantar pressures and contact area between normal and cavus foot.

    PubMed

    Fernández-Seguín, Lourdes M; Diaz Mancha, Juan Antonio; Sánchez Rodríguez, Raquel; Escamilla Martínez, Elena; Gómez Martín, Beatriz; Ramos Ortega, Javier

    2014-02-01

    In pes cavus, the medial longitudinal arch elevation reduces the contact surface area and consequently increases the corresponding plantar pressure measurements. This poor distribution of loads may produce associated pathology and pain in this or other areas of the body. Normal reference values need to be established in order to determine which patterns are prone to pathology. To compare the plantar pressures and weight-bearing surface in a population with pes cavus to a population with neutral feet. The sample comprised 68 adults, 34 with pes cavus and 34 with neutral feet. The Footscan USB Gait Clinical System(®) was used as a platform to measure the total contact area and plantar pressure under the forefoot, midfoot, hindfoot, each metatarsal head, and the overall metatarsal area. A statistical analysis of the data was performed using Student's t-test for independent samples. The pes cavus subjects showed a significant reduction in their weight-bearing area [neutral feet: 165.04 ( ± 20.68) cm(2); pes cavus: 118.26 ( ± 30.31) cm(2); p < 0.001] and significantly increased pressures under all zones of the forefoot except the fifth metatarsal [metatarsal pressure: in neutral feet 503,797 ( ± 9.32) kPa; in pes cavus 656.12 ( ± 22.39) kPa; p < 0.001]. Compared to neutral feet, pes cavus feet show a reduction in total contact surface and the load under the first toe. A significant increase is present in the load under the metatarsal areas, but the relative distribution of this load is similar in both groups. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. The Effect of Contact Area on the Fluid Flow-Fracture Specific Stiffness Relationship

    NASA Astrophysics Data System (ADS)

    Petrovitch, C.; Pyrak-Nolte, L. J.; Nolte, D. D.

    2009-12-01

    The integrity of subsurface CO2 sequestration sites can be compromised by the presence of mechanical discontinuities such as fractures, joints and faults. The ability to detect, seismically, and determine whether a discontinuity poses a risk, requires an understanding of the interrelationships among the mechanical, hydraulic and seismic properties of fractures rock. We performed a computational study to investigate the effect of fracture geometry on the relationship between fluid flow and fracture specific stiffness. The form of this relationship and the ability to scale it among different sample sizes provides a key link between the hydraulic and seismic response of fractures. In this study, model fracture topologies were simulated using the stratified continuum percolation method. This method constructs a hierarchical aperture distribution with a tunable spatial correlation length. Fractures with correlated and uncorrelated aperture distributions were used. The contact area across the fracture plane ranged from approximately 5% to 40%. The fracture specific stiffness was calculated by deforming each fracture numerically under a normal load and extracting the stiffness from the displacement-stress curves. Single-phase flow was calculated for each increment of stress by modeling the fracture topology as a network of elliptical pipes and solving the corresponding linear system of equations. We analyzed the relationship between fracture displacement and contact area and found that the correlation length associated with the contact area distribution enables a scaling relationship between displacement and contact area. The collapse of the fluid flow - stress relationship required use of standard percolation functional forms that use average aperture (cubic law), the void area fraction, and the correlation length of the contact area clusters. A final scaling relationship between fluid flow and fracture specific was found for the class of correlated fractures while a

  13. External Validation of Contact Surface Area as a Predictor of Postoperative Renal Function in Patients Undergoing Partial Nephrectomy.

    PubMed

    Haifler, Miki; Ristau, Benjamin T; Higgins, Andrew M; Smaldone, Marc C; Kutikov, Alexander; Zisman, Amnon; Uzzo, Robert G

    2017-09-20

    We sought to externally validate a mathematical formula for tumor contact surface area as a predictor of postoperative renal function in patients undergoing partial nephrectomy for renal cell carcinoma. We queried a prospectively maintained kidney cancer database for patients who underwent partial nephrectomy between 2014 and 2016. Contact surface area was calculated using data obtained from preoperative cross-sectional imaging. The correlation between contact surface area and perioperative variables was examined. The correlation between postoperative renal functional outcomes, contact surface area and the R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines and tumor touches main renal artery or vein) nephrometry score was also assessed. A total of 257 patients who underwent partial nephrectomy had sufficient data to enter the study. Median contact surface area was 14.5 cm 2 (IQR 6.2-36) and the median nephrometry score was 9 (IQR 7-10). Spearman correlation analysis showed that contact surface area correlated with estimated blood loss (r s = 0.42, p <0.001), length of stay (r s = 0.18, p = 0.005), and percent and absolute change in the estimated glomerular filtration rate (r s = -0.77 and -0.78, respectively, each p <0.001). On multivariable analysis contact surface area and nephrometry score were independent predictors of the absolute change in the estimated glomerular filtration rate (each p <0.001). ROC curve analysis revealed that contact surface area was a better predictor of a greater than 20% postoperative decline in the estimated glomerular filtration rate compared with the nephrometry score (AUC 0.94 vs 0.80). Contact surface area correlated with the change in postoperative renal function after partial nephrectomy. It can be used in conjunction with the nephrometry score to counsel patients about the risk of renal functional decline after partial

  14. The fraction of total hand surface area involved in young children's outdoor hand-to-object contacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AuYeung, Willa; Canales, Robert A.; Leckie, James O.

    2008-11-15

    Information on the fraction of total hand surface area touching a contaminated object is necessary in accurately estimating contaminant (e.g., pesticides, pathogens) loadings onto the hands during hand-to-object contacts. While several existing physical-stochastic human exposure models require such surface area data to estimate dermal and non-dietary ingestion exposure, there are very limited data sets. This paper provides statistical distributions of fractional surface areas (FSAs) for children's outdoor hand contacts. These distributions were constructed by combining information collected from two distinct studies exploring children's activity patterns and quantifying hand contact surface area. Results show that for outdoor contacts with 'All Objects',more » a range of 0.13-0.27 captured median FSAs, while a range of 0.12-0.24 captured time-weighted FSAs. Overall, an FSA of 0.31 captured 80-100% of FSAs involved in each child's outdoor hand contacts, depending upon the object of interest. These values are much lower than the often conservative assumptions of up to 1 (i.e., the entire hand) that researchers currently make regarding FSAs involved in indoor and outdoor contacts [USEPA, 1997. Standard operating procedures (SOPs) for residential exposure assessments. Contract no. 68-W6-0030. < (http://www.epa.gov/pesticides/trac/science/trac6a05.pdf)>].« less

  15. The Effect of Pile-Up and Contact Area on Hardness Test by Nanoindentation

    NASA Astrophysics Data System (ADS)

    Miyake, Koji; Fujisawa, Satoru; Korenaga, Atsushi; Ishida, Takao; Sasaki, Shinya

    2004-07-01

    We used atomic force microscopy (AFM) for the indentation test evaluating the indentation hardness of materials in the nanometer range. BK7, fused silica, and single-crystal silicon were used as test sample materials. The data analysis processes used to determine the contact area were important in evaluating the indentation hardness of the materials. The direct measurement of the size of the residual hardness impression was useful in evaluating the contact area even in the nanometer region. The results led us to conclude that AFM indentation using a sharp indenter is a powerful method for estimating the indentation hardness in the nanometer range.

  16. Investigation of force, contact area, and dwell time in finger-tapping tasks on membrane touch interface.

    PubMed

    Liu, Na; Yu, Ruifeng

    2018-06-01

    This study aimed to determine the touch characteristics during tapping tasks on membrane touch interface and investigate the effects of posture and gender on touch characteristics variables. One hundred participants tapped digits displayed on a membrane touch interface on sitting and standing positions using all fingers of the dominant hand. Touch characteristics measures included average force, contact area, and dwell time. Across fingers and postures, males exerted larger force and contact area than females, but similar dwell time. Across genders and postures, thumb exerted the largest force and the force of the other four fingers showed no significant difference. The contact area of the thumb was the largest, whereas that of the little finger was the smallest; the dwell time of the thumb was the longest, whereas that of the middle finger was the shortest. Relationships among finger sizes, gender, posture and touch characteristics were proposed. The findings helped direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Practitioner Summary: This study measured force, contact area, and dwell time in tapping tasks on membrane touch interface and examined effects of gender and posture on force, contact area, and dwell time. The findings will direct membrane touch interface design for digital and numerical control products from hardware and software perspectives.

  17. Rubber friction: The contribution from the area of real contact

    NASA Astrophysics Data System (ADS)

    Tiwari, A.; Miyashita, N.; Espallargas, N.; Persson, B. N. J.

    2018-06-01

    There are two contributions to the friction force when a rubber block is sliding on a hard and rough substrate surface, namely, a contribution Fad = τf A from the area of real contact A and a viscoelastic contribution Fvisc from the pulsating forces exerted by the substrate asperities on the rubber block. Here we present experimental results obtained at different sliding speeds and temperatures, and we show that the temperature dependency of the shear stress τf, for temperatures above the rubber glass transition temperature Tg, is weaker than that of the bulk viscoelastic modulus. The physical origin of τf for T > Tg is discussed, and we propose that its temperature dependency is determined by the rubber molecule segment mobility at the sliding interface, which is higher than in the bulk because of increased free-volume effect due to the short-wavelength surface roughness. This is consistent with the often observed reduction in the glass transition temperature in nanometer-thick surface layers of glassy polymers. For temperatures T < Tg, the shear stress τf is nearly velocity independent and of similar magnitude as observed for glassy polymers such as PMMA or polyethylene. In this case, the rubber undergoes plastic deformations in the asperity contact regions and the contact area is determined by the rubber penetration hardness. For this case, we propose that the frictional shear stress is due to slip at the interface between the rubber and a transfer film adsorbed on the concrete surface.

  18. Contralateral Occlusion Test: The effect of external ear canal occlusion on hearing thresholds.

    PubMed

    Reis, Luis Roque; Fernandes, Paulo; Escada, Pedro

    Bedside testing with tuning forks may decrease turnaround time and improve decision making for a quick qualitative assessment of hearing loss. The purpose of this study was to quantify the effects of ear canal occlusion on hearing, in order to decide which tuning fork frequency is more appropriate to use for quantifying hearing loss with the Contralateral Occlusion Test. Twenty normal-hearing adults (forty ears) underwent sound field pure tone audiometry with and without ear canal occlusion. Each ear was tested with the standard frequencies. The contralateral ear was suppressed with by masking. Ear occlusion was performed by two examiners. Participants aged between 21 and 30 years (25.6±3.03 years) showed an increase in hearing thresholds with increasing frequencies from 19.94dB (250Hz) to 39.25dB (2000Hz). The threshold difference between occluded and unoccluded conditions was statistically significant and increased from 10.69dB (250Hz) to 32.12dB (2000Hz). There were no statistically significant differences according to gender or between the examiners. The occlusion effect increased the hearing thresholds and became more evident with higher frequencies. The occlusion method as performed demonstrated reproducibility. In the Contralateral Occlusion Test, 256Hz or 512Hz tuning forks should be used for diagnosis of mild hearing loss, and a 2048Hz tuning fork should be used for moderate hearing loss. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  19. [Cilioretinal artery occlusion and central retinal vein occlusion complicating hyperhomocysteinemia: a case report].

    PubMed

    Berkani, Z; Kitouni, Y; Belhadj, A; Sifi, K; Abbadi, N; Bellatrache, C; Hartani, D; Kherroubi, R

    2013-09-01

    picture is variable depending on the location of the occlusion, the extent of the ischemic area and the degree of macular involvement. The etiologies of RVO are varied, requiring a thorough biological assessment in young subjects. The association between hyperhomocysteinemia and RVO is proven, while this association with the MTHFR C677T polymorphism was not found. Vitamin therapy reduces plasma levels of homocysteine by 25% but its role in the treatment and prevention of RVO remains to be demonstrated. Several cases of occlusion of the central retinal vein or one of its branches have been published. Combined occlusion of the central retinal vein and cilioretinal artery secondary to hyperhomocysteinemia does not appear to have been published, which would make our case unique. Copyright © 2013. Published by Elsevier Masson SAS.

  20. Multidisciplinary approach to an asymmetric traumatic occlusion: a case report.

    PubMed

    Pinho, T; Coutinho-Alves, C; Neves, M

    2013-01-01

    The case of a 47-year-old female patient with an asymmetric traumatic occlusion, great alveolar destruction in the mandibular left central incisor, gingival recession with attachment loss and lack o fkeratinized tissue more accentuated in the crossbite teeth is described. This situation was caused by the traumatic position of the teeth, aggravated by a forced asymmetric anterior position of the mandible and aggravated by mandibular movements. After the extraction of the left central mandibular incisor, keratinized tissue reconstruction and alveolar bone regeneration were performed to obtain enough bone to move the adjacent teeth in this direction and allow the correct placement of an implant at the end of orthodontic treatment. The orthodontic treatment achieved general stable occlusal contacts and esthetic results that were finalized with a definitive prosthetic treatment. This interdisciplinary management was important to solve in the present case the seriously compromised function and esthetics that would never be achieved without this combination.

  1. Impact of the Occlusion Duration on the Performance of J-CTO Score in Predicting Failure of Percutaneous Coronary Intervention for Chronic Total Occlusion.

    PubMed

    de Castro-Filho, Antonio; Lamas, Edgar Stroppa; Meneguz-Moreno, Rafael A; Staico, Rodolfo; Siqueira, Dimytri; Costa, Ricardo A; Braga, Sergio N; Costa, J Ribamar; Chamié, Daniel; Abizaid, Alexandre

    2017-06-01

    The present study examined the association between Multicenter CTO Registry in Japan (J-CTO) score in predicting failure of percutaneous coronary intervention (PCI) correlating with the estimated duration of chronic total occlusion (CTO). The J-CTO score does not incorporate estimated duration of the occlusion. This was an observational retrospective study that involved all consecutive procedures performed at a single tertiary-care cardiology center between January 2009 and December 2014. A total of 174 patients, median age 59.5 years (interquartile range [IQR], 53-65 years), undergoing CTO-PCI were included. The median estimated occlusion duration was 7.5 months (IQR, 4.0-12.0 months). The lesions were classified as easy (score = 0), intermediate (score = 1), difficult (score = 2), and very difficult (score ≥3) in 51.1%, 33.9%, 9.2%, and 5.7% of the patients, respectively. Failure rate significantly increased with higher J-CTO score (7.9%, 20.3%, 50.0%, and 70.0% in groups with J-CTO scores of 0, 1, 2, and ≥3, respectively; P<.001). There was no significant difference in success rate according to estimated duration of occlusion (P=.63). Indeed, J-CTO score predicted failure of CTO-PCI independently of the estimated occlusion duration (P=.24). Areas under receiver-operating characteristic curves were computed and it was observed that for each occlusion time period, the discriminatory capacity of the J-CTO score in predicting CTO-PCI failure was good, with a C-statistic >0.70. The estimated duration of occlusion had no influence on the J-CTO score performance in predicting failure of PCI in CTO lesions. The probability of failure was mainly determined by grade of lesion complexity.

  2. Occlusal Enamel Complexity in Middle Miocene to Holocene Equids (Equidae: Perissodactyla) of North America

    PubMed Central

    Famoso, Nicholas A.; Davis, Edward Byrd

    2014-01-01

    Four groups of equids, “Anchitheriinae,” Merychippine-grade Equinae, Hipparionini, and Equini, coexisted in the middle Miocene, but only the Equini remains after 16 Myr of evolution and extinction. Each group is distinct in its occlusal enamel pattern. These patterns have been compared qualitatively but rarely quantitatively. The processes influencing the evolution of these occlusal patterns have not been thoroughly investigated with respect to phylogeny, tooth position, and climate through geologic time. We investigated Occlusal Enamel Index, a quantitative method for the analysis of the complexity of occlusal patterns. We used analyses of variance and an analysis of co-variance to test whether equid teeth increase resistive cutting area for food processing during mastication, as expressed in occlusal enamel complexity, in response to increased abrasion in their diet. Results suggest that occlusal enamel complexity was influenced by climate, phylogeny, and tooth position through time. Occlusal enamel complexity in middle Miocene to Modern horses increased as the animals experienced increased tooth abrasion and a cooling climate. PMID:24587267

  3. VoroMQA: Assessment of protein structure quality using interatomic contact areas.

    PubMed

    Olechnovič, Kliment; Venclovas, Česlovas

    2017-06-01

    In the absence of experimentally determined protein structure many biological questions can be addressed using computational structural models. However, the utility of protein structural models depends on their quality. Therefore, the estimation of the quality of predicted structures is an important problem. One of the approaches to this problem is the use of knowledge-based statistical potentials. Such methods typically rely on the statistics of distances and angles of residue-residue or atom-atom interactions collected from experimentally determined structures. Here, we present VoroMQA (Voronoi tessellation-based Model Quality Assessment), a new method for the estimation of protein structure quality. Our method combines the idea of statistical potentials with the use of interatomic contact areas instead of distances. Contact areas, derived using Voronoi tessellation of protein structure, are used to describe and seamlessly integrate both explicit interactions between protein atoms and implicit interactions of protein atoms with solvent. VoroMQA produces scores at atomic, residue, and global levels, all in the fixed range from 0 to 1. The method was tested on the CASP data and compared to several other single-model quality assessment methods. VoroMQA showed strong performance in the recognition of the native structure and in the structural model selection tests, thus demonstrating the efficacy of interatomic contact areas in estimating protein structure quality. The software implementation of VoroMQA is freely available as a standalone application and as a web server at http://bioinformatics.lt/software/voromqa. Proteins 2017; 85:1131-1145. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    PubMed

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  5. Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

    PubMed

    Pizanis, Antonius; Holstein, Jörg H; Vossen, Felix; Burkhardt, Markus; Pohlemann, Tim

    2013-08-26

    Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only

  6. Visualisation of urban airborne laser scanning data with occlusion images

    NASA Astrophysics Data System (ADS)

    Hinks, Tommy; Carr, Hamish; Gharibi, Hamid; Laefer, Debra F.

    2015-06-01

    Airborne Laser Scanning (ALS) was introduced to provide rapid, high resolution scans of landforms for computational processing. More recently, ALS has been adapted for scanning urban areas. The greater complexity of urban scenes necessitates the development of novel methods to exploit urban ALS to best advantage. This paper presents occlusion images: a novel technique that exploits the geometric complexity of the urban environment to improve visualisation of small details for better feature recognition. The algorithm is based on an inversion of traditional occlusion techniques.

  7. The effect of body postures on the distribution of air gap thickness and contact area.

    PubMed

    Mert, Emel; Psikuta, Agnes; Bueno, Marie-Ange; Rossi, René M

    2017-02-01

    The heat and mass transfer in clothing is predominantly dependent on the thickness of air layer and the magnitude of contact area between the body and the garment. The air gap thickness and magnitude of the contact area can be affected by the posture of the human body. Therefore, in this study, the distribution of the air gap and the contact area were investigated for different body postures of a flexible manikin. In addition, the effect of the garment fit (regular and loose) and style (t-shirts, sweatpants, jacket and trousers) were analysed for the interaction between the body postures and the garment properties. A flexible manikin was scanned using a three-dimensional (3D) body scanning technique, and the scans were post-processed in dedicated software. The body posture had a strong effect on the air gap thickness and the contact area for regions where the garment had a certain distance from the body. Furthermore, a mathematical model was proposed to estimate the possible heat transfer coefficient for the observed air layers and their change with posture. The outcome of this study can be used to improve the design of the protective and functional garments and predict their effect on the human body.

  8. Acute stroke with major intracranial vessel occlusion: Characteristics of cardioembolism and atherosclerosis-related in situ stenosis/occlusion.

    PubMed

    Horie, Nobutaka; Tateishi, Yohei; Morikawa, Minoru; Morofuji, Yoichi; Hayashi, Kentaro; Izumo, Tsuyoshi; Tsujino, Akira; Nagata, Izumi; Matsuo, Takayuki

    2016-10-01

    Acute ischemic stroke with major intracranial vessel occlusion is commonly due to cardioembolic or atherosclerosis-related in situ stenosis/occlusion, and immediate identification of these subtypes is important to establish the optimal treatment strategy. The aim of this study was to clarify the differences in clinical presentation, radiological findings, neurological temporal courses, and outcomes between these etiologies, which have not been fully evaluated. Consecutive emergency patients with acute ischemic stroke were retrospectively reviewed. Among them, patients with stroke with major intracranial vessel occlusion were analyzed with a focus on clinical and radiological findings, and a comparison was performed for those with cardioembolic or atherosclerosis-related in situ stenosis/occlusion. Of 1053 patients, 80 had stroke with acute major intracranial vessel occlusion (45 with cardioembolic and 35 with atherosclerosis-related in situ stenosis/occlusion). Interestingly, the susceptibility vessel sign (SVS) on T2-weighted MR angiography was more frequently detected in cardioembolic stroke (80.0%) than in atherosclerosis (in situ stenosis: 5.9%, chronic occlusion: 14.3%). Moreover, the proximal intra-arterial signal (IAS) on arterial spin labeling MRI and the distal IAS on fluid attenuated inversion recovery MRI was less frequently detected in chronic occlusion (27.3% and 50.0%, respectively) than in acute occlusion due to cardioembolic or in situ stenosis. Multivariate regression analysis showed that the SVS was significantly related to cardioembolism (adjusted odds ratio (OR): 21.68, P=0.004). Clinical characteristics of acute stroke with major intracranial vessel occlusion differ depending on the etiology. The SVS and proximal/distal IAS on MRI are useful to distinguish between cardioembolic and atherosclerotic-related in situ stenosis/occlusion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Imaging surface contacts: Power law contact distributions and contact stresses in quartz, calcite, glass and acrylic plastic

    USGS Publications Warehouse

    Dieterich, J.H.; Kilgore, B.D.

    1996-01-01

    A procedure has been developed to obtain microscope images of regions of contact between roughened surfaces of transparent materials, while the surfaces are subjected to static loads or undergoing frictional slip. Static loading experiments with quartz, calcite, soda-lime glass and acrylic plastic at normal stresses to 30 MPa yield power law distributions of contact areas from the smallest contacts that can be resolved (3.5 ??m2) up to a limiting size that correlates with the grain size of the abrasive grit used to roughen the surfaces. In each material, increasing normal stress results in a roughly linear increase of the real area of contact. Mechanisms of contact area increase are by growth of existing contacts, coalescence of contacts and appearance of new contacts. Mean contacts stresses are consistent with the indentation strength of each material. Contact size distributions are insensitive to normal stress indicating that the increase of contact area is approximately self-similar. The contact images and contact distributions are modeled using simulations of surfaces with random fractal topographies. The contact process for model fractal surfaces is represented by the simple expedient of removing material at regions where surface irregularities overlap. Synthetic contact images created by this approach reproduce observed characteristics of the contacts and demonstrate that the exponent in the power law distributions depends on the scaling exponent used to generate the surface topography.

  10. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Recurrence of amblyopia after occlusion therapy.

    PubMed

    Bhola, Rahul; Keech, Ronald V; Kutschke, Pamela; Pfeifer, Wanda; Scott, William E

    2006-11-01

    To determine the stability of visual acuity (VA) after a standardized occlusion regimen in children with strabismic and/or anisometropic amblyopia. Retrospective, population-based, consecutive observational case series. Four hundred forty-nine patients younger than 10 years who underwent an occlusion trial for amblyopia and were observed until there was a recurrence of amblyopia or for a maximum of 1 year after decrease or cessation of occlusion therapy. We performed a retrospective chart review of all patients treated by occlusion therapy for strabismic and/or anisometropic amblyopia at our institution over a 34-year period. Of the 1621 patients identified in our database, 449 met the eligibility criteria and were included in this study. Patients having at least a 2 logarithm of the minimum angle of resolution (logMAR)-level improvement in VA by optotypes or a change from unmaintained to maintained fixation preference during the course of occlusion therapy were included. A recurrence of amblyopia was defined as > or =2 logMAR levels of VA reduction or reversal of fixation preference within 1 year after a decrease or cessation of occlusion therapy. Recurrence of amblyopia after a decrease or cessation of occlusion therapy and its relationship with patient age and VA of the amblyopic eye at the time of decrease or cessation of occlusion therapy. Of 653 occlusion trials, 179 (27%) resulted in recurrence of amblyopia. The recurrence was found to be inversely correlated with patient age. There was no statistically significant association between the recurrence of amblyopia and VA of the amblyopic eye at the end of maximal occlusion therapy. There is a clinically important risk of amblyopia recurrence when occlusion therapy is decreased before the age of 10 years. The risk of recurrence is inversely correlated with age (P<0.0001).

  12. Natural mediotrusive contact: does it affect the masticatory and neck EMG activity during tooth grinding?

    PubMed

    Fuentes, Aler D; Martin, Conchita; Bull, Ricardo; Santander, Hugo; Gutiérrez, Mario F; Miralles, Rodolfo

    2015-12-29

    There is scarce knowledge regarding the influence of a natural mediotrusive contact on mandibular and cervical muscular activity. The purpose of this study was to analyze the EMG activity of the anterior temporalis (AT) and sternocleidomastoid (SCM) muscles during awake grinding in healthy subjects with or without a natural mediotrusive occlusal contact. 15 subjects with natural mediotrusive occlusal contact (Group 1) and 15 subjects without natural mediotrusive occlusal contact (Group 2) participated. Bilateral surface EMG activity of AT and SCM muscles was recorded during unilateral eccentric or concentric tooth grinding tasks. EMG activity was normalized against the activity recorded during maximal voluntary clenching in intercuspal position (IP) for AT muscles and during maximal intentional isometric head-neck rotation to each side, for SCM muscles. EMG activity of AT and SCM muscles showed no statistical difference between groups. EMG activity of AT muscle was higher in the working side (WS) than in the non-WS (NWS) in Group 1 during concentric grinding (0.492 vs 0.331, P = 0.047), whereas no difference was observed in Group 2. EMG activity of SCM was similar between working and NWSs in both groups and tasks. Asymmetry indexes (AIs) were not significantly different between groups. These findings in healthy subjects support the assumption that during awake tooth grinding, central nerve control predominates over peripheral inputs, and reinforce the idea of a functional link between the motor-neuron pools that control jaw and neck muscles.

  13. Natural mediotrusive contact: does it affect the masticatory and neck EMG activity during tooth grinding?

    PubMed

    Fuentes, Aler D; Martin, Conchita; Bull, Ricardo; Santander, Hugo; Gutiérrez, Mario F; Miralles, Rodolfo

    2016-07-01

    There is scarce knowledge regarding the influence of a natural mediotrusive contact on mandibular and cervical muscular activity. The purpose of this study was to analyze the EMG activity of the anterior temporalis (AT) and sternocleidomastoid (SCM) muscles during awake grinding in healthy subjects with or without a natural mediotrusive occlusal contact. Fifteen subjects with natural mediotrusive occlusal contact (Group 1) and 15 subjects without natural mediotrusive occlusal contact (Group 2) participated. Bilateral surface EMG activity of AT and SCM muscles was recorded during unilateral eccentric or concentric tooth grinding tasks. EMG activity was normalized against the activity recorded during maximal voluntary clenching in intercuspal position (IP) for AT muscles and during maximal intentional isometric head-neck rotation to each side, for SCM muscles. EMG activity of AT and SCM muscles showed no statistical difference between groups. EMG activity of AT muscle was higher in the working side (WS) than in the non-WS (NWS) in Group 1 during concentric grinding (0.492 vs 0.331, p = 0.047), whereas no difference was observed in Group 2. EMG activity of SCM was similar between working and NWSs in both groups and tasks. Asymmetry indexes (AIs) were not significantly different between groups. These findings in healthy subjects support the assumption that during awake tooth grinding, central nerve control predominates over peripheral inputs, and reinforce the idea of a functional link between the motor-neuron pools that control jaw and neck muscles.

  14. Rubber friction: The contribution from the area of real contact.

    PubMed

    Tiwari, A; Miyashita, N; Espallargas, N; Persson, B N J

    2018-06-14

    There are two contributions to the friction force when a rubber block is sliding on a hard and rough substrate surface, namely, a contribution F ad = τ f A from the area of real contact A and a viscoelastic contribution F visc from the pulsating forces exerted by the substrate asperities on the rubber block. Here we present experimental results obtained at different sliding speeds and temperatures, and we show that the temperature dependency of the shear stress τ f , for temperatures above the rubber glass transition temperature T g , is weaker than that of the bulk viscoelastic modulus. The physical origin of τ f for T > T g is discussed, and we propose that its temperature dependency is determined by the rubber molecule segment mobility at the sliding interface, which is higher than in the bulk because of increased free-volume effect due to the short-wavelength surface roughness. This is consistent with the often observed reduction in the glass transition temperature in nanometer-thick surface layers of glassy polymers. For temperatures T < T g , the shear stress τ f is nearly velocity independent and of similar magnitude as observed for glassy polymers such as PMMA or polyethylene. In this case, the rubber undergoes plastic deformations in the asperity contact regions and the contact area is determined by the rubber penetration hardness. For this case, we propose that the frictional shear stress is due to slip at the interface between the rubber and a transfer film adsorbed on the concrete surface.

  15. [Temporomandibular joint, occlusion and bruxism].

    PubMed

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. The effectiveness of occlusal splints for sleep bruxism.

    PubMed

    Jagger, Robert

    2008-01-01

    Searches were made using the Cochrane Oral Health Group's Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Embase, LILACS (Latin American & Caribbean Health Sciences Literature), Biblioteca Brasileira de Odontologia, and Dissertations, Theses and Abstracts. Hand searches were made of abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. Randomised controlled trials (RCT) or quasi-RCT were chosen that compared splint therapy concurrently with no treatment, other occlusal appliances, or any other intervention in participants who had sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCT were identified of which five were eventually included. In these, use of an occlusal splint was compared with palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant difference between the occlusal splint and control groups were found in meta-analysis. There is not enough evidence to state that the occlusal splint is effective for treating sleep bruxism. Indication of its use is questionable with regard to sleep outcomes, but there may be some benefit with regard to tooth wear. This systematic review suggests the need for further investigation in more controlled RCT that pay attention to method of allocation, outcome assessment, large sample size, and sufficient duration of followup. The study design must be parallel in order to eliminate

  17. On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.

    PubMed

    Falk, H

    1990-01-01

    The main aims of this thesis were (1) to study the functional characteristics of dentitions with mandibular implant-supported fixed cantilever prostheses - IFCP s- occluding with complete dentures, (2) to study in detail the magnitudes and distributions of axially directed closing and chewing forces in such dentitions, (3) to study the influence of number and distribution of occlusal contacts on the magnitude and distribution of closing and chewing forces, (4) to assess the vertical bending moment and the resulting vertical bending stress in the cantilever joints and (5) to find out whether the force distribution over the cantilever beams and the resulting vertical bending stress in the cantilever joint are influenced by the type of prosthetic construction in the opposing jaw. Closing and chewing forces were registered in altogether seventeen subjects by means of miniature strain gauge transducers mounted bilaterally and symmetrically in performed matrices in prosthetic appliances. Four, six or eight transducers, evenly distributed over the tooth-arch, permitted registrations of axially directed occlusal forces in several occluding areas simultaneously. In Papers I-IV, the implant-supported prostheses were installed in the mandible and occluded with complete dentures. In Paper V, group A, the fixture-supported prostheses were installed in the maxilla and occluded with tooth-supported fixed partial dentures whereas in group B, the arrangements were analogous to those in Papers I-IV. All subjects exhibited a rhythmic chewing pattern and preferred one side for chewing although both sides were used. Most chewing sequences were terminated with swallowing with occlusal force development. The mean total forces acting over the tooth-arch varied somewhat between groups and occlusal arrangements but averaged 350 and 170 N for closing and chewing respectively. Closing and chewing forces increased distally along the cantilever beams when occluding with complete dentures and

  18. Direct measurements of the pressure distribution along the contact area during droplet impact

    NASA Astrophysics Data System (ADS)

    Nguyen, Thanh-Vinh; Matsumoto, Kiyoshi; Shimoyama, Isao

    2016-11-01

    We report direct measurements of the pressure distribution on the contact area during the impact of a droplet on a micropillar array. The measurements were realized using an array of MEMS-based force sensors fabricated underneath the micropillars. We show that immediately after the droplet hits the surface, the pressure becomes maximum at the center of the contact area and this maximum pressure value is more than 10 times larger than the dynamic pressure. This result emphasizes the effect of water-hammer-type pressure during the early stage of the impact. Furthermore, our measurement results demonstrate that the critical pressure associated with Cassie-Wenzel transition agrees well with the maximum capillary pressure of the micropillar array.

  19. Effect of gender, facial dimensions, body mass index and type of functional occlusion on bite force.

    PubMed

    Koç, Duygu; Doğan, Arife; Bek, Bülent

    2011-01-01

    Some factors such as gender, age, craniofacial morphology, body structure, occlusal contact patterns may affect the maximum bite force. Thus, the purposes of this study were to determine the mean maximum bite force in individuals with normal occlusion, and to examine the effect of gender, facial dimensions, body mass index (BMI), type of functional occlusion (canine guidance and group function occlusion) and balancing side interferences on it. Thirty-four individuals aged 19-20 years-old were selected for this study. Maximum bite force was measured with strain-gauge transducers at first molar region. Facial dimensions were defined by standardized frontal photographs as follows: anterior total facial height (ATFH), bizygomathic facial width (BFW) and intergonial width (IGW). BMI was calculated using the equation weight/height². The type of functional occlusion and the balancing side interferences of the subjects were identified by clinical examination. Bite force was found to be significantly higher in men than women (p<0.05). While there was a negative correlation between the bite force and ATFH/BFW, ATFH/IGW ratios in men (p<0.05), women did not show any statistically significant correlation (p>0.05). BMI and bite force correlation was not statistically significant (p>0.05). The average bite force did not differ in subjects with canine guidance or group function occlusion and in the presence of balancing side interferences (p>0.05). Data suggest that bite force is affected by gender. However, BMI, type of functional occlusion and the presence of balancing side interferences did not exert a meaningful influence on bite force. In addition, transverse facial dimensions showed correlation with bite force in only men.

  20. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  1. Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems.

    PubMed

    Sharif-Kashani, Pooria; Fanney, Douglas; Injev, Val

    2014-07-30

    Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, the WhiteStar Signature® Phacoemulsification System, and the Centurion® Vision System using gravity-fed fluidics. Centurion Active FluidicsTM were also tested at multiple intraoperative pressure target settings. Vacuum rise time was evaluated for Infiniti, WhiteStar Signature, Centurion, and Stellaris® Vision Enhancement systems. Rise time to vacuum limits of 400 and 600 mmHg was assessed at flow rates of 30 and 60 cc/minute. Occlusion break surge was analyzed by 2-way analysis of variance. The Centurion system exhibited substantially less occlusion break surge than the other systems tested. Surge area with Centurion Active Fluidics was similar to gravity fluidics at an equivalent bottle height. At all Centurion Active Fluidics intraoperative pressure target settings tested, surge was smaller than with Infiniti and WhiteStar Signature. Infiniti had the fastest vacuum rise time and Stellaris had the slowest. No system tested reached the 600-mmHg vacuum limit. In this laboratory study, Centurion had the least occlusion break surge and similar vacuum rise times compared with the other systems tested. Reducing occlusion break surge may increase safety of phacoemulsification cataract surgery.

  2. Occlusal splints for treating sleep bruxism (tooth grinding).

    PubMed

    Macedo, C R; Silva, A B; Machado, M A; Saconato, H; Prado, G F

    2007-10-17

    Sleep bruxism is an oral activity characterised by teeth grinding or clenching during sleep. Several treatments for sleep bruxism have been proposed such as pharmacological, psychological, and dental. To evaluate the effectiveness of occlusal splints for the treatment of sleep bruxism with alternative interventions, placebo or no treatment. We searched the Cochrane Oral Health Group's Trials Register (to May 2007); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, Issue 1); MEDLINE (1966 to May 2007); EMBASE (1980 to May 2007); LILACS (1982 to May 2007); Biblioteca Brasileira de Odontologia (1982 to May 2007); Dissertation, Theses and Abstracts (1981 to May 2007); and handsearched abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. We selected randomised or quasi-randomised controlled trials (RCTs), in which splint therapy was compared concurrently to no treatment, other occlusal appliances, or any other intervention in participants with sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCTs were identified. Twenty-four trials were excluded. Five RCTs were included. Occlusal splint was compared to: palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant differences between the occlusal splint and control groups were found in the meta-analyses. There is not sufficient evidence to state that the occlusal splint is

  3. Effect of solution and leaf surface polarity on droplet spread area and contact angle.

    PubMed

    Nairn, Justin J; Forster, W Alison; van Leeuwen, Rebecca M

    2016-03-01

    How much an agrochemical spray droplet spreads on a leaf surface can significantly influence efficacy. This study investigates the effect solution polarity has on droplet spreading on leaf surfaces and whether the relative leaf surface polarity, as quantified using the wetting tension dielectric (WTD) technique, influences the final spread area. Contact angles and spread areas were measured using four probe solutions on 17 species. Probe solution polarity was found to affect the measured spread area and the contact angle of the droplets on non-hairy leaves. Leaf hairs skewed the spread area measurement, preventing investigation of the influence of surface polarity on hairy leaves. WTD-measured leaf surface polarity of non-hairy leaves was found to correlate strongly with the effect of solution polarity on spread area. For non-polar leaf surfaces the spread area decreases with increasing solution polarity, for neutral surfaces polarity has no effect on spread area and for polar leaf surfaces the spread area increases with increasing solution polarity. These results attest to the use of the WTD technique as a means to quantify leaf surface polarity. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  4. Prediction of bead area contact load at the tire-wheel interface using NASTRAN

    NASA Technical Reports Server (NTRS)

    Chen, C. H. S.

    1982-01-01

    The theoretical prediction of the bead area contact load at the tire wheel interface using NASTRAN is reported. The application of the linear code to a basically nonlinear problem results in excessive deformation of the structure and the tire-wheel contact conditions become impossible to achieve. A psuedo-nonlinear approach was adopted in which the moduli of the cord reinforced composite are increased so that the computed key deformations matched that of the experiment. Numerical results presented are discussed.

  5. Investigation of membranous ventricular septal defect complicated with tricuspid regurgitation in ventricular septal defect occlusion

    PubMed Central

    LIU, SHU-PING; LI, LI; YAO, KE-CHUN; WANG, NA; WANG, JIAN-CHANG

    2013-01-01

    This study aimed to explore the mechanism of membranous ventricular septal defect complicated with tricuspid regurgitation and the significance of ventricular septal defect occlusion by echocardiography. A total of 43 patients with membranous ventricular septal defect complicated with tricuspid regurgitation were observed by echocardiography and the changes in length, area and volume of tricuspid regurgitation prior to and following ventricular septal defect occlusion were measured. There were four different mechanisms of membranous ventricular septal defect complicated with tricuspid regurgitation. The various indices of tricuspid regurgitation volume were significantly reduced following occlusion. Ventricular septal defect occlusion significantly reduces tricuspid regurgitation volume complicated with membranous ventricular septal defect and echocardiography is an ideal method to detect these changes. PMID:23404058

  6. COMPARATIVE EVALUATION OF THE EFFICACY OF OCCLUSAL SPLINTS FABRICATED IN CENTRIC RELATION OR MAXIMUM INTERCUSPATION IN TEMPOROMANDIBULAR DISORDERS PATIENTS

    PubMed Central

    Hamata, Marcelo Matida; Zuim, Paulo Renato Junqueira; Garcia, Alicio Rosalino

    2009-01-01

    Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous origin and bruxism were divided into 2 groups treated with splints in maximum intercuspation (I) or centric relation (II). Clinical, electrognathographic and electromyographic examinations were performed before and 3 months after therapy. Data were analyzed by the Student's t test. Differences at 5% level of probability were considered statistically significant. There was a remarkable reduction in pain symptomatology, without statistically significant differences (p>0.05) between the groups. There was mandibular repositioning during therapy, as demonstrated by the change in occlusal contacts on the splints. Electrognathographic examination demonstrated a significant increase in maximum left lateral movement for group I and right lateral movement for group II (p<0.05). There were no significant differences (p>0.05) in the electromyographic activities at rest after utilization of both splints. In conclusion, both occlusal splints were effective for pain control and presented similar action. The results suggest that maximum intercuspation may be used for fabrication of occlusal splints in patients with occlusal stability without large discrepancies between centric relation and maximum intercuspation. Moreover, this technique is simpler and less expensive. PMID:19148403

  7. Three-dimensional in vivo patellofemoral kinematics and contact area of anterior cruciate ligament-deficient and -reconstructed subjects using magnetic resonance imaging.

    PubMed

    Shin, Choongsoo S; Carpenter, R Dana; Majumdar, Sharmila; Ma, C Benjamin

    2009-11-01

    The purpose of this study was to test whether (1) the 3-dimensional in vivo patellofemoral kinematics and patellofemoral contact area of anterior cruciate ligament (ACL)-deficient knees are different from those of normal, contralateral knees and (2) ACL reconstruction restores in vivo patellofemoral kinematics and contact area. Ten ACL-deficient knees and twelve ACL-reconstructed knees, as well as the contralateral uninjured knees, were tested. Magnetic resonance imaging was performed at full extension and 40 degrees of flexion under simulated partial weight-bearing conditions. Six-degrees of freedom patellofemoral kinematics, patellofemoral contact area, and contact location were analyzed by use of magnetic resonance image-based 3-dimensional patellofemoral knee models. The patella in the ACL-deficient knees underwent significantly more lateral tilt during flexion (P < .05) and tended to translate more laterally (P = .083) than the patella in contralateral knees. After ACL reconstruction, no kinematic parameters were significantly different from those in contralateral knees. The patellofemoral contact areas of ACL-deficient knees at both the extended and flexed positions (37 +/- 22 mm(2) and 357 +/- 53 mm(2), respectively) were significantly smaller than those of contralateral knees (78 +/- 45 mm(2) and 437 +/- 119 mm(2), respectively) (P < .05). After reconstruction, the patellofemoral contact area of ACL-reconstructed knees in the extended position (86 +/- 41 mm(2)) was significantly larger (P < .05) than that of contralateral knees (50 +/- 34 mm(2)), but no difference was detected in the flexed position. Reproducibility of all patellofemoral kinematic parameters, contact centroid translation, and contact area showed coefficients of variation of less than 6.8%. ACL injuries alter patellofemoral kinematics including patellar tilt and patellar lateral translation, but ACL reconstruction with hamstring or allograft restores altered patellar tilt. ACL injuries

  8. Occlusal relief changes with molar wear in Pan troglodytes troglodytes and Gorilla gorilla gorilla.

    PubMed

    M'kirera, Francis; Ungar, Peter S

    2003-06-01

    Most research on primate tooth form-function relationships has focused on unworn teeth. This study presents a morphological comparison of variably worn lower second molars (M(2)s) of lowland gorillas (Gorilla gorilla gorilla; n=47) and common chimpanzees (Pan troglodytes troglodytes; n=54) using dental topographic analysis. High-resolution replicas of occlusal surfaces were prepared and scanned in 3D by laser scanning. The resulting elevation data were used to create a geographic information system (GIS) for each tooth. Occlusal relief, defined as the ratio of 3D surface area to 2D planometric area of the occlusal table, was calculated and compared between wear stages, taxa, and sexes. The results failed to show a difference in occlusal relief between males and females of a given taxon, but did evince differences between wear stages and between taxa. A lack of significant interaction between wear stage and taxon factors suggests that differences in occlusal relief between chimpanzees and gorillas are maintained throughout the wear sequence. These results add to a growing body of information on how molar teeth change with wear, and how differences between primate species are maintained at comparable points throughout the wear sequence. Such studies provide new insights into form-function relationships, which will allow us to infer certain aspects of diet in fossils with worn teeth.

  9. Effect of resistance exercise training combined with relatively low vascular occlusion.

    PubMed

    Sumide, Takahiro; Sakuraba, Keishoku; Sawaki, Keisuke; Ohmura, Hirotoshi; Tamura, Yoshifumi

    2009-01-01

    Previous studies have demonstrated that a low-intensity resistance exercise, combined with vascular occlusion, results in a marked increase in muscular size and strength. We investigated the optimal pressure for reduction of muscle blood flow with resistance exercise to increase the muscular strength and endurance. Twenty-one subjects were randomly divided into four groups by the different application of vascular occlusion pressure at the proximal of thigh: without any pressure (0-pressure group), with a pressure of 50mmHg (50-pressure group), with a pressure of 150mmHg (150-pressure group), and with a pressure of 250mmHg (250-pressure group). The isokinetic muscle strength at angular velocities of 60 and 180 degrees /s, total muscle work, and the cross-sectional knee extensor muscle area were assessed before and after exercise. Exercise was performed three times a week over an 8-week period at an intensity of approximately 20% of one-repetition maximum for straight leg raising and hip joint adduction and maximum force for abduction training. A significant increase in strength at 180 degrees /s was noted after exercise in all subjects who exercised under vascular occlusion. Total muscle work increased significantly in the 50- and 150-pressure groups (P<0.05, P<0.01, respectively). There was no significant increase in cross-sectional knee extensor muscle area in any groups. In conclusion, resistance exercise with relatively low vascular occlusion pressure is potentially useful to increase muscle strength and endurance without discomfort.

  10. Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

    PubMed

    Leumann, Andre; Fortuna, Rafael; Leonard, Tim; Valderrabano, Victor; Herzog, Walter

    2015-01-01

    The menisci are thought to modulate load transfer and to absorb shocks in the knee joint. No study has experimentally measured the meniscal functions in the intact, in vivo joint loaded by physiologically relevant muscular contractions. Right knee joints of seven New Zealand white rabbits were loaded using isometric contractions of the quadriceps femoris muscles controlled by femoral nerve stimulation. Isometric knee extensor torques at the maximal and two submaximal force levels were performed at knee angles of 70°, 90°, 110°, and 130°. Patellofemoral and tibiofemoral contact areas and pressure distributions were measured using Fuji Presensor film inserted above and below the menisci and also with the menisci removed. Meniscectomy was associated with a decrease in tibiofemoral contact area ranging from 30 to 70% and a corresponding increase in average contact pressures. Contact areas measured below the menisci were consistently larger than those measured on top of the menisci. Contact areas in the patellofemoral joint (PFJ), and peak pressures in tibiofemoral and PFJs, were not affected by meniscectomy. Contact areas and peak pressures in all joints depended crucially on knee joint angle and quadriceps force: The more flexed the knee joint was, the larger were the contact areas and the higher were the peak pressures. In agreement with the literature, removal of the menisci was associated with significant decreases in tibiofemoral contact area and corresponding increases in average contact pressures, but surprisingly, peak pressures remained unaffected, indicating that the function of the menisci is to distribute loads across a greater contact area.

  11. Biomechanical factors related to occlusal load transfer in removable complete dentures.

    PubMed

    Żmudzki, Jarosław; Chladek, Grzegorz; Kasperski, Jacek

    2015-08-01

    Owing to economic conditions, removable dentures remain popular despite the discomfort and reduced chewing efficiency experienced by most denture wearers. However, there is little evidence to confirm that the level of mucosal load exceeds the pressure pain threshold. This discrepancy stimulated us to review the current state of knowledge on the biomechanics of mastication with complete removable dentures. The loading beneath dentures was analyzed in the context of denture foundation characteristics, salivary lubrication, occlusal forces, and the biomechanics of mastication. The analysis revealed that the interpretation of data collected in vivo is hindered due to the simultaneous overlapping effects of many variables. In turn, problems with determining the pressure beneath a denture and analyzing frictional processes constitute principal limitations of in vitro model studies. Predefined conditions of finite element method simulations should include the effects of oblique mastication forces, simultaneous detachment and sliding of the denture on its foundation, and the stabilizing role of balancing contacts. This review establishes that previous investigations may have failed because of their unsubstantiated assumption that, in a well-working balanced occlusion, force is only exerted perpendicular to the occlusal plane, allowing the denture to sit firmly on its foundation. Recent improvements in the simulation of realistic biomechanical denture behavior raise the possibility of assessing the effects of denture design on the pressures and slides beneath the denture.

  12. Effect on Bone Architecture of Marginal Grooves in Dental Implants Under Occlusal Loaded Conditions in Beagle Dogs.

    PubMed

    Kato, Hatsumi; Kuroshima, Shinichiro; Inaba, Nao; Uto, Yusuke; Sawase, Takashi

    2018-02-01

    The aim of this study was to clarify whether marginal grooves on dental implants affect osseointegration, bone structure, and the alignment of collagen fibers to determine bone quality under loaded conditions. Anodized Ti-6Al-4V alloy dental implants, with and without marginal grooves (test and control implants, respectively), were used (3.7 × 8.0 mm). Fourth premolars and first molars of 6 beagle mandibles were extracted. Two control and test implants were placed in randomly selected healed sites at 12 weeks after tooth extraction. Screw-retained single crowns for first molars were fabricated. Euthanasia was performed at 8 weeks after the application of occlusal forces. Implant marginal bone level, bone to implant contact (BIC), bone structure around dental implants, and the alignment of collagen fibers determining bone quality were analyzed. The marginal bone level in test implants was significantly higher than that in control implants. Occlusal forces significantly increased BIC in test implants ( P = .007), whereas BIC did not change in control implants, irrespective of occlusal forces ( P = .303). Moreover, occlusal forces significantly increased BIC in test implants compared with control implants ( P = .032). Additionally, occlusal forces preferentially aligned collagen fibers in test implants, but not control implants. Hence, marginal grooves on dental implants have positive effects on increased osseointegration and adapted bone quality based on the preferential alignment of collagen fibers around dental implants under loaded conditions.

  13. Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems

    PubMed Central

    2014-01-01

    Background Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. Methods Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, the WhiteStar Signature® Phacoemulsification System, and the Centurion® Vision System using gravity-fed fluidics. Centurion Active FluidicsTM were also tested at multiple intraoperative pressure target settings. Vacuum rise time was evaluated for Infiniti, WhiteStar Signature, Centurion, and Stellaris® Vision Enhancement systems. Rise time to vacuum limits of 400 and 600 mmHg was assessed at flow rates of 30 and 60 cc/minute. Occlusion break surge was analyzed by 2-way analysis of variance. Results The Centurion system exhibited substantially less occlusion break surge than the other systems tested. Surge area with Centurion Active Fluidics was similar to gravity fluidics at an equivalent bottle height. At all Centurion Active Fluidics intraoperative pressure target settings tested, surge was smaller than with Infiniti and WhiteStar Signature. Infiniti had the fastest vacuum rise time and Stellaris had the slowest. No system tested reached the 600-mmHg vacuum limit. Conclusions In this laboratory study, Centurion had the least occlusion break surge and similar vacuum rise times compared with the other systems tested. Reducing occlusion break surge may increase safety of phacoemulsification cataract surgery. PMID:25074069

  14. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

    PubMed Central

    Sukotjo, Cortino

    2013-01-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387

  15. Analysis of hand contact areas and interaction capabilities during manipulation and exploration.

    PubMed

    Gonzalez, Franck; Gosselin, Florian; Bachta, Wael

    2014-01-01

    Manual human-computer interfaces for virtual reality are designed to allow an operator interacting with a computer simulation as naturally as possible. Dexterous haptic interfaces are the best suited for this goal. They give intuitive and efficient control on the environment with haptic and tactile feedback. This paper is aimed at helping in the choice of the interaction areas to be taken into account in the design of such interfaces. The literature dealing with hand interactions is first reviewed in order to point out the contact areas involved in exploration and manipulation tasks. Their frequencies of use are then extracted from existing recordings. The results are gathered in an original graphical interaction map allowing for a simple visualization of the way the hand is used, and compared with a map of mechanoreceptors densities. Then an interaction tree, mapping the relative amount of actions made available through the use of a given contact area, is built and correlated with the losses of hand function induced by amputations. A rating of some existing haptic interfaces and guidelines for their design are finally achieved to illustrate a possible use of the developed graphical tools.

  16. Large area tunnel oxide passivated rear contact n -type Si solar cells with 21.2% efficiency: Large area tunnel oxide passivated rear contact n -type Si solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Yuguo; Upadhyaya, Vijaykumar; Chen, Chia-Wei

    This paper reports on the implementation of carrier-selective tunnel oxide passivated rear contact for high-efficiency screen-printed large area n-type front junction crystalline Si solar cells. It is shown that the tunnel oxide grown in nitric acid at room temperature (25°C) and capped with n+ polysilicon layer provides excellent rear contact passivation with implied open-circuit voltage iVoc of 714mV and saturation current density J0b of 10.3 fA/cm2 for the back surface field region. The durability of this passivation scheme is also investigated for a back-end high temperature process. In combination with an ion-implanted Al2O3-passivated boron emitter and screen-printed front metal grids,more » this passivated rear contact enabled 21.2% efficient front junction Si solar cells on 239 cm2 commercial grade n-type Czochralski wafers.« less

  17. Intraoral versus extraoral measurement of the height of the interproximal contact area in maxillary anterior teeth.

    PubMed

    Sghaireen, Mohd G; Albhiran, Heyam Mobark; Alzoubi, Ibrahim A; Lynch, Edward; Al-Omiri, Mahmoud K

    2015-01-01

    This study aimed to clinically quantify the apicoincisal height of the upper interproximal areas directly in patients' mouths compared to measurements on stone models. One hundred and fifty participants (75 females and 75 males, age range 20-45 years) were recruited for this study. A digital caliper was used to measure the anterior maxillary interproximal contact areas directly in patients' mouths and on stone models. The digital caliper accuracy was up to 0.01. The Statistical Package for Social Sciences software (SPSS, version 19.0, Chicago, Ill., USA) was used for statistical analysis. Statistical significance was based on probability values <0.05. The intraoral measurement of proximal contacts as well as the measurement on stone models showed that the dimensions of interproximal contacts on both sides of each tooth were significantly different (p < 0.001) and that the dimension of the mesial contact point was larger than that of the distal contact point of each tooth. The largest contact point was the one between the central incisors (direct intraoral measurement = 2.9-6.49 mm; model measurement = 3.31-6.91 mm). On the other hand, the contact point between the canine and first premolar was the smallest on both sides of the arch (0.63-2.52 mm intraorally, 0.98-2.88 mm on models). The intraoral measurement of contact points was more accurate than model measurements, and the differences were statistically significant (p < 0.001). The clinical evaluation of contact point dimensions using a digital caliper was more precise than measuring contact points on stone models; hence, it is a viable, quick and adequate method to be used routinely. © 2015 S. Karger AG, Basel.

  18. Axoglial contacts in the area postrema of the cat - An ultrastructural study

    NASA Technical Reports Server (NTRS)

    Damelio, Fernando E.; Gibbs, Michael A.; Mehler, William R.; Philpott, Delbert E.; Savage, Wayne

    1986-01-01

    Axoglial contacts were observed in an ultrastructural study of the area postrema of the cat. According to the disposition of the electron-dense projections attached to the adjoining membranes these contacts were classified as symmetrical or asymmetrical. The axon profiles contained aggregations of clear vesicles randomly distributed or grouped in clusters adjacent to the electron-dense projections. Dense core vesicles were occasionally seen. The neuroglial profiles were either astrocytic or ependymoglial in nature. The astrocytes showed a clear cytoplasm, polymorphous vesicles, mitochondria, glycogen granules, and bundles of filaments. The ependymal cells, in contrast, had a more electron-dense and granular appearance, tubular structures, irregular vesicular formations, profiles of smooth reticuloendoplasm, and filaments grouped in bundles or isolated in the cytoplasm. The possibility that these contacts might play a role in the chemical transfer from neurons to glial cells is discussed on the basis of existing biochemical data.

  19. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.

    PubMed

    Yoshida, H; Faust, A; Wilckens, J; Kitagawa, M; Fetto, J; Chao, Edmund Y-S

    2006-01-01

    Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.

  20. AFM-based tribological study of nanopatterned surfaces: the influence of contact area instabilities.

    PubMed

    Rota, A; Serpini, E; Gazzadi, G C; Valeri, S

    2016-04-06

    Although the importance of morphology on the tribological properties of surfaces has long been proved, an exhaustive understanding of nanopatterning effects is still lacking due to the difficulty in both fabricating 'really nano-' structures and detecting their tribological properties. In the present work we show how the probe-surface contact area can be a critical parameter due to its remarkable local variability, making a correct interpretation of the data very difficult in the case of extremely small nanofeatures. Regular arrays of parallel 1D straight nanoprotrusions were fabricated by means of a low-dose focused ion beam, taking advantage of the amorphization-related swelling effect. The tribological properties of the patterns were detected in the presence of air and in vacuum (dry ambient) by atomic force microscopy. We have introduced a novel procedure and data analysis to reduce the uncertainties related to contact instabilities. The real time estimation of the radius of curvature of the contacting asperity enables us to study the dependence of the tribological properties of the patterns from their geometrical characteristics. The effect of the patterns on both adhesion and the coefficient of friction strongly depends on the contact area, which is linked to the local radius of curvature of the probe. However, a detectable hydrophobic character induced on the hydrophilic native SiO2 has been observed as well. The results suggest a scenario for capillary formation on the patterns.

  1. Anatomic double-bundle anterior cruciate ligament reconstruction restores patellofemoral contact areas and pressures more closely than nonanatomic single-bundle reconstruction.

    PubMed

    Tajima, Goro; Iriuchishima, Takanori; Ingham, Sheila J M; Shen, Wei; van Houten, Albert H; Aerts, Maarten M; Shimamura, Tadashi; Smolinski, Patrick; Fu, Freddie H

    2010-10-01

    To investigate the effects of anterior cruciate ligament (ACL) deficiency and nonanatomic single-bundle (SB) and anatomic double-bundle (DB) ACL reconstruction on the contact characteristics of the patellofemoral (PF) joint. By use of a materials testing system, 7 fresh-frozen human cadaveric knees were tested. The following states were tested: ACL-intact knee, nonanatomic SB ACL reconstruction, anatomic DB ACL reconstruction, and ACL-deficient knee. Hamstring autografts were used. PF contact pressures and areas were measured with pressure-sensitive film at 30°, 60°, and 90° of knee flexion with a constant 100-N load on the quadriceps tendon. The total contact area of ACL-deficient and nonanatomic SB ACL-reconstructed knees (123.8 ± 63.9 and 149.6 ± 79.3 mm(2), respectively) significantly decreased when compared with those of the intact knee (206.1 ± 83.6 mm(2)) at 30° of knee flexion. The lateral-facet peak pressure of ACL-deficient and nonanatomic SB ACL-reconstructed knees (1.12 ± 0.52 and 1.22 ± 0.54 MPa, respectively) significantly decreased when compared with those of the intact knee (0.68 ± 0.38 MPa) at 90° of knee flexion. Anatomic DB ACL reconstruction restored the contact pressures and areas to values similar to those of the intact knee (no significant difference). ACL deficiency resulted in a significant decrease in the total and medial PF contact areas and in an increase in the lateral PF contact pressure. Anatomic DB ACL reconstruction more closely restored normal PF contact area and pressure than did nonanatomic SB ACL reconstruction. Our findings suggest that the changes in the PF contact area and pressures in ACL deficiency and after nonanatomic SB ACL reconstruction may be one of the causes of PF osteoarthritis or other related PF problems found at long-term follow-up. Anatomic DB ACL reconstruction may reduce the incidence of PF problems by closely restoring the contact area and pressure. Copyright © 2010 Arthroscopy Association of

  2. Detecting natural occlusion boundaries using local cues

    PubMed Central

    DiMattina, Christopher; Fox, Sean A.; Lewicki, Michael S.

    2012-01-01

    Occlusion boundaries and junctions provide important cues for inferring three-dimensional scene organization from two-dimensional images. Although several investigators in machine vision have developed algorithms for detecting occlusions and other edges in natural images, relatively few psychophysics or neurophysiology studies have investigated what features are used by the visual system to detect natural occlusions. In this study, we addressed this question using a psychophysical experiment where subjects discriminated image patches containing occlusions from patches containing surfaces. Image patches were drawn from a novel occlusion database containing labeled occlusion boundaries and textured surfaces in a variety of natural scenes. Consistent with related previous work, we found that relatively large image patches were needed to attain reliable performance, suggesting that human subjects integrate complex information over a large spatial region to detect natural occlusions. By defining machine observers using a set of previously studied features measured from natural occlusions and surfaces, we demonstrate that simple features defined at the spatial scale of the image patch are insufficient to account for human performance in the task. To define machine observers using a more biologically plausible multiscale feature set, we trained standard linear and neural network classifiers on the rectified outputs of a Gabor filter bank applied to the image patches. We found that simple linear classifiers could not match human performance, while a neural network classifier combining filter information across location and spatial scale compared well. These results demonstrate the importance of combining a variety of cues defined at multiple spatial scales for detecting natural occlusions. PMID:23255731

  3. PARACENTRAL ACUTE MIDDLE MACULOPATHY ASSOCIATED WITH RETINAL ARTERY OCCLUSION AFTER COSMETIC FILLER INJECTION.

    PubMed

    Sridhar, Jayanth; Shahlaee, Abtin; Shieh, Wen-Shi; Rahimy, Ehsan

    2017-01-01

    To report a single case of paracentral acute middle maculopathy in association with retinal artery occlusion in the setting of ipsilateral facial cosmetic filler injection. Case report. A 35-year-old woman presenting with sudden vision loss to finger count vision immediately after left nasal fat pad cosmetic filler injection. Dilated funduscopic examination revealed a swollen optic disc with multiple branch arterial occlusions with visible embolic material. Fluorescein angiography confirmed multiple branch arterial occlusions in addition to a focal choroidal infarction in the macula. Spectral-domain optical coherence tomography revealed middle retinal hyperreflectivity in the superotemporal macula consistent with paracentral acute middle maculopathy. En face optical coherence tomography demonstrated a superotemporal area of whitening at the level of the deep capillary plexus corresponding to the paracentral acute middle maculopathy lesion seen on spectral-domain optical coherence tomography. On twelve-month follow-up, final visual acuity was 20/100 due to optic neuropathy. Emboli from cosmetic facial filler injections may rarely result in ipsilateral arterial occlusions and now have a novel association with paracentral acute middle maculopathy likely due to deep capillary plexus feeder vessel occlusion.

  4. High-frequency imaging of elastic contrast and contact area with implications for naturally observed changes in fault properties

    USGS Publications Warehouse

    Nagata, Kohei; Kilgore, Brian D.; Beeler, Nicholas M.; Nakatani, Masao

    2014-01-01

    During localized slip of a laboratory fault we simultaneously measure the contact area and the dynamic fault normal elastic stiffness. One objective is to determine conditions where stiffness may be used to infer changes in area of contact during sliding on nontransparent fault surfaces. Slip speeds between 0.01 and 10 µm/s and normal stresses between 1 and 2.5 MPa were imposed during velocity step, normal stress step, and slide-hold-slide tests. Stiffness and contact area have a linear interdependence during rate stepping tests and during the hold portion of slide-hold-slide tests. So long as linearity holds, measured fault stiffness can be used on nontransparent materials to infer changes in contact area. However, there are conditions where relations between contact area and stiffness are nonlinear and nonunique. A second objective is to make comparisons between the laboratory- and field-measured changes in fault properties. Time-dependent changes in fault zone normal stiffness made in stress relaxation tests imply postseismic wave speed changes on the order of 0.3% to 0.8% per year in the two or more years following an earthquake; these are smaller than postseismic increases seen within natural damage zones. Based on scaling of the experimental observations, natural postseismic fault normal contraction could be accommodated within a few decimeter wide fault core. Changes in the stiffness of laboratory shear zones exceed 10% per decade and might be detectable in the field postseismically.

  5. A review of micro-contact physics for microelectromechanical systems (MEMS) metal contact switches

    NASA Astrophysics Data System (ADS)

    Toler, Benjamin F.; Coutu, Ronald A., Jr.; McBride, John W.

    2013-10-01

    Innovations in relevant micro-contact areas are highlighted, these include, design, contact resistance modeling, contact materials, performance and reliability. For each area the basic theory and relevant innovations are explored. A brief comparison of actuation methods is provided to show why electrostatic actuation is most commonly used by radio frequency microelectromechanical systems designers. An examination of the important characteristics of the contact interface such as modeling and material choice is discussed. Micro-contact resistance models based on plastic, elastic-plastic and elastic deformations are reviewed. Much of the modeling for metal contact micro-switches centers around contact area and surface roughness. Surface roughness and its effect on contact area is stressed when considering micro-contact resistance modeling. Finite element models and various approaches for describing surface roughness are compared. Different contact materials to include gold, gold alloys, carbon nanotubes, composite gold-carbon nanotubes, ruthenium, ruthenium oxide, as well as tungsten have been shown to enhance contact performance and reliability with distinct trade offs for each. Finally, a review of physical and electrical failure modes witnessed by researchers are detailed and examined.

  6. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhudesai, V., E-mail: v_prabhudesai@hotmail.com; Mitra, K.; West, D. J.

    2003-09-15

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome.

  7. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  8. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  9. Acute left main coronary artery occlusion

    PubMed Central

    Burgazli, K. Mehmet; Bilgin, Mehmet; Soydan, Nedim; Chasan, Ridvan; Erdogan, Ali

    2013-01-01

    The treatment of an acute left main coronary artery occlusion still poses a challenge. In this case report we present a 50-year-old patient with an acute occlusion of the left main artery. After a successful angioplasty without “stenting” due to the complexity of the stenosis the patient underwent a successful bypass surgery. We discuss the therapeutic options of acute left main occlusion regarding medical, interventional and surgical options. PMID:24353543

  10. The influence of muscle pennation angle and cross-sectional area on contact forces in the ankle joint

    PubMed Central

    Sopher, Ran S; Amis, Andrew A; Davies, D Ceri; Jeffers, Jonathan RT

    2016-01-01

    Data about a muscle’s fibre pennation angle and physiological cross-sectional area are used in musculoskeletal modelling to estimate muscle forces, which are used to calculate joint contact forces. For the leg, muscle architecture data are derived from studies that measured pennation angle at the muscle surface, but not deep within it. Musculoskeletal models developed to estimate joint contact loads have usually been based on the mean values of pennation angle and physiological cross-sectional area. Therefore, the first aim of this study was to investigate differences between superficial and deep pennation angles within each muscle acting over the ankle and predict how differences may influence muscle forces calculated in musculoskeletal modelling. The second aim was to investigate how inter-subject variability in physiological cross-sectional area and pennation angle affects calculated ankle contact forces. Eight cadaveric legs were dissected to excise the muscles acting over the ankle. The mean surface and deep pennation angles, fibre length and physiological cross-sectional area were measured. Cluster analysis was applied to group the muscles according to their architectural characteristics. A previously validated OpenSim model was used to estimate ankle muscle forces and contact loads using architecture data from all eight limbs. The mean surface pennation angle for soleus was significantly greater (54%) than the mean deep pennation angle. Cluster analysis revealed three groups of muscles with similar architecture and function: deep plantarflexors and peroneals, superficial plantarflexors and dorsiflexors. Peak ankle contact force was predicted to occur before toe-off, with magnitude greater than five times bodyweight. Inter-specimen variability in contact force was smallest at peak force. These findings will help improve the development of experimental and computational musculoskeletal models by providing data to estimate force based on both surface and deep

  11. The influence of muscle pennation angle and cross-sectional area on contact forces in the ankle joint.

    PubMed

    Sopher, Ran S; Amis, Andrew A; Davies, D Ceri; Jeffers, Jonathan Rt

    2017-01-01

    Data about a muscle's fibre pennation angle and physiological cross-sectional area are used in musculoskeletal modelling to estimate muscle forces, which are used to calculate joint contact forces. For the leg, muscle architecture data are derived from studies that measured pennation angle at the muscle surface, but not deep within it. Musculoskeletal models developed to estimate joint contact loads have usually been based on the mean values of pennation angle and physiological cross-sectional area. Therefore, the first aim of this study was to investigate differences between superficial and deep pennation angles within each muscle acting over the ankle and predict how differences may influence muscle forces calculated in musculoskeletal modelling. The second aim was to investigate how inter-subject variability in physiological cross-sectional area and pennation angle affects calculated ankle contact forces. Eight cadaveric legs were dissected to excise the muscles acting over the ankle. The mean surface and deep pennation angles, fibre length and physiological cross-sectional area were measured. Cluster analysis was applied to group the muscles according to their architectural characteristics. A previously validated OpenSim model was used to estimate ankle muscle forces and contact loads using architecture data from all eight limbs. The mean surface pennation angle for soleus was significantly greater (54%) than the mean deep pennation angle. Cluster analysis revealed three groups of muscles with similar architecture and function: deep plantarflexors and peroneals, superficial plantarflexors and dorsiflexors. Peak ankle contact force was predicted to occur before toe-off, with magnitude greater than five times bodyweight. Inter-specimen variability in contact force was smallest at peak force. These findings will help improve the development of experimental and computational musculoskeletal models by providing data to estimate force based on both surface and deep

  12. Investigation of welded interconnection of large area wraparound contacted silicon solar cells

    NASA Technical Reports Server (NTRS)

    Lott, D. R.

    1984-01-01

    An investigation was conducted to evaluate the welding and temperature cycle testing of large area 5.9 x 5.9 wraparound silicon solar cells utilizing printed circuit substrates with SSC-155 interconnect copper metals and the LMSC Infrared Controlled weld station. An initial group of 5 welded modules containing Phase 2 developmental 5.9 x 5.9 cm cells were subjected to cyclical temperatures of + or 80 C at a rate of 120 cycles per day. Anomalies were noted in the adhesion of the cell contact metallization; therefore, 5 additional modules were fabricated and tested using available Phase I cells with demonstrated contact integrity. Cycling of the later module type through 12,000 cycles indicated the viability of this type of lightweight flexible array concept. This project demonstrated acceptable use of an alternate interconnect copper in combination with large area wraparound cells and emphasized the necessity to implement weld pull as opposed to solder pull procedures at the cell vendors for cells that will be interconnected by welding.

  13. Near-IR multi-modal imaging of natural occlusal lesions

    NASA Astrophysics Data System (ADS)

    Lee, Dustin; Fried, Daniel; Darling, Cynthia L.

    2009-02-01

    Reflectance and transillumination imaging show demineralization with high contrast in the near-IR. The objective of this study is to use lesion size and contrast acquired in reflectance and transillumination near-infrared imaging modes to estimate the severity of natural occlusal caries lesions. Previous studies have shown that near-infrared (NIR) light can be used to effectively image artificial carious lesions. However, its efficacy on natural lesions requires further exploration. Fifty extracted teeth with varying amounts of occlusal decay were examined using a NIR imaging system operating at 1310-nm. Image analysis software was used to calculate contrast values between sound and carious tooth structure. After imaging, teeth were histologically sampled at 1-mm intervals in order to determine lesion depth. Lesion contrast in transillumination mode significantly increased with lesion depth (p<0.001), while lesion contrast in reflectance mode did not increase. The lesion area demonstrated a significant increase with lesion severity in both imaging modes. These results suggest that lesion contrast and area can be used to estimate lesion severity in NIR images.

  14. Neuromuscular dentistry: Occlusal diseases and posture.

    PubMed

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture.

  15. Defining the value of injection current and effective electrical contact area for EGaIn-based molecular tunneling junctions.

    PubMed

    Simeone, Felice C; Yoon, Hyo Jae; Thuo, Martin M; Barber, Jabulani R; Smith, Barbara; Whitesides, George M

    2013-12-04

    Analysis of rates of tunneling across self-assembled monolayers (SAMs) of n-alkanethiolates SCn (with n = number of carbon atoms) incorporated in junctions having structure Ag(TS)-SAM//Ga2O3/EGaIn leads to a value for the injection tunnel current density J0 (i.e., the current flowing through an ideal junction with n = 0) of 10(3.6±0.3) A·cm(-2) (V = +0.5 V). This estimation of J0 does not involve an extrapolation in length, because it was possible to measure current densities across SAMs over the range of lengths n = 1-18. This value of J0 is estimated under the assumption that values of the geometrical contact area equal the values of the effective electrical contact area. Detailed experimental analysis, however, indicates that the roughness of the Ga2O3 layer, and that of the Ag(TS)-SAM, determine values of the effective electrical contact area that are ~10(-4) the corresponding values of the geometrical contact area. Conversion of the values of geometrical contact area into the corresponding values of effective electrical contact area results in J0(+0.5 V) = 10(7.6±0.8) A·cm(-2), which is compatible with values reported for junctions using top-electrodes of evaporated Au, and graphene, and also comparable with values of J0 estimated from tunneling through single molecules. For these EGaIn-based junctions, the value of the tunneling decay factor β (β = 0.75 ± 0.02 Å(-1); β = 0.92 ± 0.02 nC(-1)) falls within the consensus range across different types of junctions (β = 0.73-0.89 Å(-1); β = 0.9-1.1 nC(-1)). A comparison of the characteristics of conical Ga2O3/EGaIn tips with the characteristics of other top-electrodes suggests that the EGaIn-based electrodes provide a particularly attractive technology for physical-organic studies of charge transport across SAMs.

  16. Non-contact ulcer area calculation system for neuropathic foot ulcer.

    PubMed

    Shah, Parth; Mahajan, Siddaram; Nageswaran, Sharmila; Paul, Sathish Kumar; Ebenzer, Mannam

    2017-08-11

    Around 125,785 new cases in year 2013-14 of leprosy were detected in India as per WHO report on leprosy in September 2015 which accounts to approximately 62% of the total new cases. Anaesthetic foot caused by leprosy leads to uneven loading of foot leading to ulcer in approximately 20% of the cases. Much efforts have gone in identifying newer techniques to efficiently monitor the progress of ulcer healing. Current techniques followed in measuring the size of ulcers, have not been found to be so accurate but are still is followed by clinicians across the globe. Quantification of prognosis of the condition would be required to understand the efficacy of current treatment methods and plan for further treatment. This study aims at developing a non contact technique to precisely measure the size of ulcer in patients affected by leprosy. Using MATLAB software, GUI was designed to process the acquired ulcer image by segmenting and calculating the pixel area of the image. The image was further converted to a standard measurement using a reference object. The developed technique was tested on 16 ulcer images acquired from 10 leprosy patients with plantar ulcers. Statistical analysis was done using MedCalc analysis software to find the reliability of the system. The analysis showed a very high correlation coefficient (r=0.9882) between the ulcer area measurements done using traditional technique and the newly developed technique, The reliability of the newly developed technique was significant with a significance level of 99.9%. The designed non-contact ulcer area calculating system using MATLAB is found to be a reliable system in calculating the size of ulcers. The technique would help clinicians have a reliable tool to monitor the progress of ulcer healing and help modify the treatment protocol if needed. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  17. Evaluation of footprint contact area and pressure using a triple-row modification of the suture-bridge technique for rotator cuff repair.

    PubMed

    Ostrander, Roger V; McKinney, Bart I

    2012-10-01

    Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  18. The influence of varying maxillary incisal edge embrasure space and interproximal contact area dimensions on perceived smile aesthetics.

    PubMed

    Foulger, T E; Tredwin, C J; Gill, D S; Moles, D R

    2010-08-14

    The aim of this study was to determine the influence of incisal edge embrasure space and interproximal contact area dimensions on perceived smile aesthetics. Cross-sectional study. Postgraduate dental teaching hospital. A photograph of a smiling female, displaying only the lips and maxillary teeth was digitally altered. First, the proportions of the incisal edge embrasure spaces were modified to produce five different images. Secondly, the lengths of the interproximal contact areas were altered to produce five different images. The two sets of photographs were ranked from 'most attractive' to 'least attractive' by 35 dentists, 35 dental technicians and 35 patients. An embrasure space arrangement where the size of the embrasures increases progressively distally from the midline was deemed most attractive; absence of embrasure spaces was deemed least attractive. In assessing the interproximal contact areas, all groups assessed an arrangement where the areas between the teeth were equal (and 50% the length of the central incisor) as most attractive, and where the contact areas increased in length progressively distally from the midline as least attractive. There were few statistically significant differences between the groups in these perceptions. Whilst there is broad agreement in what the participant groups deem to be aesthetic, our findings do not wholly correspond to the 'ideals' that have been previously suggested in the dental literature.

  19. Dental occlusion and temporomandibular disorders.

    PubMed

    Stone, J Caitlin; Hannah, Andrew; Nagar, Nathan

    2017-10-27

    Data sourcesMedline, Scopus and Google Scholar.Study selectionTwo reviewers selected studies independently. English language clinical studies assessing the association between temporomandibular disorders (TMD) and features of dental occlusion were considered.Data extraction and synthesisStudy quality was assessed based on the Newcastle-Ottawa Scale (NOS) and a narrative synthesis was presented.ResultsIn all 25 studies (17 case-control, eight comparative) were included. Overall there was a high variability between occlusal features and TMD diagnosis. Findings were consistent with a lack of clinically relevant association between TMD and dental occlusion. Only two studies were associated with TMD in the majority (≥50%) of single variable analyses in patient populations. Only mediotrusive interferences are associated with TMD in the majority of multiple variable analyses.ConclusionsThe findings support the absence of a disease-specific association, there is no ground to hypothesise a major role for dental occlusion in the pathophysiology of TMDs. Dental clinicians are thus encouraged to move forward and abandon the old-fashioned gnathological paradig.

  20. Conventional occlusion versus pharmacologic penalization for amblyopia.

    PubMed

    Li, Tianjing; Shotton, Kate

    2009-10-07

    Amblyopia is defined as defective visual acuity in one or both eyes without demonstrable abnormality of the visual pathway, and is not immediately resolved by wearing glasses. To assess the effectiveness and safety of conventional occlusion versus atropine penalization for amblyopia. We searched CENTRAL, MEDLINE, EMBASE, LILACS, the WHO International Clinical Trials Registry Platform, preference lists, science citation index and ongoing trials up to June 2009. We included randomized/quasi-randomized controlled trials comparing conventional occlusion to atropine penalization for amblyopia. Two authors independently screened abstracts and full text articles, abstracted data, and assessed the risk of bias. Three trials with a total of 525 amblyopic eyes were included. One trial was assessed as having a low risk of bias among these three trials, and one was assessed as having a high risk of bias.Evidence from three trials suggests atropine penalization is as effective as conventional occlusion. One trial found similar improvement in vision at six and 24 months. At six months, visual acuity in the amblyopic eye improved from baseline 3.16 lines in the occlusion and 2.84 lines in the atropine group (mean difference 0.034 logMAR; 95% confidence interval (CI) 0.005 to 0.064 logMAR). At 24 months, additional improvement was seen in both groups; but there continued to be no meaningful difference (mean difference 0.01 logMAR; 95% CI -0.02 to 0.04 logMAR). The second trial reported atropine to be more effective than occlusion. At six months, visual acuity improved 1.8 lines in the patching group and 3.4 lines in the atropine penalization group, and was in favor of atropine (mean difference -0.16 logMAR; 95% CI -0.23 to -0.09 logMAR). Different occlusion modalities were used in these two trials. The third trial had inherent methodological flaws and limited inference could be drawn.No difference in ocular alignment, stereo acuity and sound eye visual acuity between occlusion and

  1. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    PubMed

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Neuromuscular dentistry: Occlusal diseases and posture

    PubMed Central

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K.

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture. PMID:25737904

  3. A neural model of visual figure-ground segregation from kinetic occlusion.

    PubMed

    Barnes, Timothy; Mingolla, Ennio

    2013-01-01

    Freezing is an effective defense strategy for some prey, because their predators rely on visual motion to distinguish objects from their surroundings. An object moving over a background progressively covers (deletes) and uncovers (accretes) background texture while simultaneously producing discontinuities in the optic flow field. These events unambiguously specify kinetic occlusion and can produce a crisp edge, depth perception, and figure-ground segmentation between identically textured surfaces--percepts which all disappear without motion. Given two abutting regions of uniform random texture with different motion velocities, one region appears to be situated farther away and behind the other (i.e., the ground) if its texture is accreted or deleted at the boundary between the regions, irrespective of region and boundary velocities. Consequently, a region with moving texture appears farther away than a stationary region if the boundary is stationary, but it appears closer (i.e., the figure) if the boundary is moving coherently with the moving texture. A computational model of visual areas V1 and V2 shows how interactions between orientation- and direction-selective cells first create a motion-defined boundary and then signal kinetic occlusion at that boundary. Activation of model occlusion detectors tuned to a particular velocity results in the model assigning the adjacent surface with a matching velocity to the far depth. A weak speed-depth bias brings faster-moving texture regions forward in depth in the absence of occlusion (shearing motion). These processes together reproduce human psychophysical reports of depth ordering for key cases of kinetic occlusion displays. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Induction of Electrode-Cellular Interfaces with ˜ 0.05 μm^2 Contact Areas

    NASA Astrophysics Data System (ADS)

    Flanders, Bret; Thapa, Prem

    2009-10-01

    Individual cells of the slime mold Dictyostelium discoideum attach themselves to negatively biased nanoelectrodes that are separated by 30 μm from grounded electrodes. There is a -43 mV voltage-threshold for cell-to-electrode attachment, with negligible probability across the 0 to -38 mV range but probability that approaches 0.7 across the -46 to -100 mV range. A cell initiates contact by extending a pseudopod to the electrode and maintains contact until the voltage is turned off. Scanning electron micrographs of these interfaces show the contact areas to be of the order of 0.05 μm^2. Insight into this straight-forward, reproducible process may lead to new electrode-cellular attachment strategies that complement established approaches, such as blind sampling and patch clamp.

  5. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    PubMed

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm 2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  6. Technetium-99m(Sn2+)pyrophosphate in ischemic and infarcted dog myocardium in early stages of acute coronary occlusion: histochemical and tissue-counting comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bianco, J.A.; Kemper, A.J.; Taylor, A.

    1983-06-01

    We have investigated the pattern of accumulation of Tc-99m(Sn2+)pyrophosphate (Tc-99m PPi) in myocardial tissue of dogs during the early stages of acute occlusion of the left anterior descending coronary artery. Three groups were studied after: (a) 40 min occlusion followed by 6 hr reperfusion (n . 6); (b) 6 hr occlusion followed by one hour reperfusion (n . 5); and (c) 7 hr occlusion with no reperfusion (n . 4). Areas of myocardial infarction were defined with triphenyl-tetrazolium chloride (TTC) staining, and blood flow was determined with 9-mu radioactive microspheres. In Group C uptake in infarcted and peri-infarct areas wasmore » not enhanced, most likely owing to low flow. In Group B, with late reperfusion, Tc-99m PPi sequestration was increased in both infarcted and peri-infarcted tissues. In Group A, areas ischemic during occlusion but with normal flow and viability by TTC after 6 hr of reperfusion showed significant uptake of Tc-99m PPi (twice the uptake of nonischemic regions).« less

  7. Improved single- and multi-contact life-time testing of dental restorative materials using key characteristics of the human masticatory system and a force/position-controlled robotic dental wear simulator.

    PubMed

    Raabe, D; Harrison, A; Ireland, A; Alemzadeh, K; Sandy, J; Dogramadzi, S; Melhuish, C; Burgess, S

    2012-03-01

    This paper presents a new in vitro wear simulator based on spatial parallel kinematics and a biologically inspired implicit force/position hybrid controller to replicate chewing movements and dental wear formations on dental components, such as crowns, bridges or a full set of teeth. The human mandible, guided by passive structures such as posterior teeth and the two temporomandibular joints, moves with up to 6 degrees of freedom (DOF) in Cartesian space. The currently available wear simulators lack the ability to perform these chewing movements. In many cases, their lack of sufficient DOF enables them only to replicate the sliding motion of a single occlusal contact point by neglecting rotational movements and the motion along one Cartesian axis. The motion and forces of more than one occlusal contact points cannot accurately be replicated by these instruments. Furthermore, the majority of wear simulators are unable to control simultaneously the main wear-affecting parameters, considering abrasive mechanical wear, which are the occlusal sliding motion and bite forces in the constraint contact phase of the human chewing cycle. It has been shown that such discrepancies between the true in vivo and the simulated in vitro condition influence the outcome and the quality of wear studies. This can be improved by implementing biological features of the human masticatory system such as tooth compliance realized through the passive action of the periodontal ligament and active bite force control realized though the central nervous system using feedback from periodontal preceptors. The simulator described in this paper can be used for single- and multi-occlusal contact testing due to its kinematics and ability to exactly replicate human translational and rotational mandibular movements with up to 6 DOF without neglecting movements along or around the three Cartesian axes. Recorded human mandibular motion and occlusal force data are the reference inputs of the simulator

  8. The role of "rescue saccades" in tracking objects through occlusions.

    PubMed

    Zelinsky, Gregory J; Todor, Andrei

    2010-12-29

    We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking.

  9. Vascular occlusion with a balloon-expandable stent occluder.

    PubMed

    Moss, J G; Laborde, J C; Clem, M C; Rivera, F J; Encarnacion, C E; Meyer, K B; Palmaz, J C

    1994-05-01

    To evaluate the effectiveness of a new vascular occlusion device. The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. This new occlusive device offers immediate vascular occlusion with excellent stability.

  10. Technical Note: Validation of two methods to determine contact area between breast and compression paddle in mammography.

    PubMed

    Branderhorst, Woutjan; de Groot, Jerry E; van Lier, Monique G J T B; Highnam, Ralph P; den Heeten, Gerard J; Grimbergen, Cornelis A

    2017-08-01

    To assess the accuracy of two methods of determining the contact area between the compression paddle and the breast in mammography. An accurate method to determine the contact area is essential to accurately calculate the average compression pressure applied by the paddle. For a set of 300 breast compressions, we measured the contact areas between breast and paddle, both capacitively using a transparent foil with indium-tin-oxide (ITO) coating attached to the paddle, and retrospectively from the obtained mammograms using image processing software (Volpara Enterprise, algorithm version 1.5.2). A gold standard was obtained from video images of the compressed breast. During each compression, the breast was illuminated from the sides in order to create a dark shadow on the video image where the breast was in contact with the compression paddle. We manually segmented the shadows captured at the time of x-ray exposure and measured their areas. We found a strong correlation between the manual segmentations and the capacitive measurements [r = 0.989, 95% CI (0.987, 0.992)] and between the manual segmentations and the image processing software [r = 0.978, 95% CI (0.972, 0.982)]. Bland-Altman analysis showed a bias of -0.0038 dm 2 for the capacitive measurement (SD 0.0658, 95% limits of agreement [-0.1329, 0.1252]) and -0.0035 dm 2 for the image processing software [SD 0.0962, 95% limits of agreement (-0.1921, 0.1850)]. The size of the contact area between the paddle and the breast can be determined accurately and precisely, both in real-time using the capacitive method, and retrospectively using image processing software. This result is beneficial for scientific research, data analysis and quality control systems that depend on one of these two methods for determining the average pressure on the breast during mammographic compression. © 2017 Sigmascreening B.V. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  11. A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venbrux, Anthony C., E-mail: avenbrux@mfa.gwu.edu; Rudakov, Leon, E-mail: leonrudakov@artventivemedical.com; Plass, Andre, E-mail: andre.plass@usz.ch

    2013-05-24

    PurposeThe purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles.MethodsThe ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males,more » ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects.ResultsThe acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients.ConclusionsAlthough we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.« less

  12. Contact Analysis of Nominally Flat Surfaces

    DTIC Science & Technology

    2008-06-01

    to analyze the simple case of Hertz-contact (a spherical body in contact with a rigid flat plane) and determine the change in contact area with...next major area was in the Hertz Contact Theory. This area allowed the authors to develop an analytical solution. The third major area was in the... bodies came into contact with one another. This research concluded with the development and testing of the Finite Element Analysis Program (FEAP) using

  13. Mapping the spatiotemporal evolution of solute transport in articular cartilage explants reveals how cartilage recovers fluid within the contact area during sliding.

    PubMed

    Graham, Brian T; Moore, Axel C; Burris, David L; Price, Christopher

    2018-04-11

    The interstitial fluid within articular cartilage shields the matrix from mechanical stresses, reduces friction and wear, enables biochemical processes, and transports solutes into and out of the avascular extracellular matrix. The balanced competition between fluid exudation and recovery under load is thus critical to the mechanical and biological functions of the tissue. We recently discovered that sliding alone can induce rapid solute transport into buried cartilage contact areas via a phenomenon termed tribological rehydration. In this study, we use in situ confocal microscopy measurements to track the spatiotemporal propagation of a small neutral solute into the buried contact area to clarify the fluid mechanics underlying the tribological rehydration phenomenon. Sliding experiments were interrupted by periodic static loading to enable scanning of the entire contact area. Spatiotemporal patterns of solute transport combined with tribological data suggested pressure driven flow through the extracellular matrix from the contact periphery rather than into the surface via a fluid film. Interestingly, these testing interruptions also revealed dynamic, repeatable and history-independent fluid loss and recovery processes consistent with those observed in vivo. Unlike the migrating contact area, which preserves hydration by moving faster than interstitial fluid can flow, our results demonstrate that the stationary contact area can maintain and actively recover hydration through a dynamic competition between load-induced exudation and sliding-induced recovery. The results demonstrate that sliding contributes to the recovery of fluid and solutes by cartilage within the contact area while clarifying the means by which it occurs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Large arterial occlusive strokes as a medical emergency: need to accurately predict clot location.

    PubMed

    Vanacker, Peter; Faouzi, Mohamed; Eskandari, Ashraf; Maeder, Philippe; Meuli, Reto; Michel, Patrik

    2017-10-01

    Endovascular treatment for acute ischemic stroke with a large intracranial occlusion was recently shown to be effective. Timely knowledge of the presence, site, and extent of arterial occlusions in the ischemic territory has the potential to influence patient selection for endovascular treatment. We aimed to find predictors of large vessel occlusive strokes, on the basis of available demographic, clinical, radiological, and laboratory data in the emergency setting. Patients enrolled in ASTRAL registry with acute ischemic stroke and computed tomography (CT)-angiography within 12 h of stroke onset were selected and categorized according to occlusion site. Easily accessible variables were used in a multivariate analysis. Of 1645 patients enrolled, a significant proportion (46.2%) had a large vessel occlusion in the ischemic territory. The main clinical predictors of any arterial occlusion were in-hospital stroke [odd ratios (OR) 2.1, 95% confidence interval 1.4-3.1], higher initial National Institute of Health Stroke Scale (OR 1.1, 1.1-1.2), presence of visual field defects (OR 1.9, 1.3-2.6), dysarthria (OR 1.4, 1.0-1.9), or hemineglect (OR 2.0, 1.4-2.8) at admission and atrial fibrillation (OR 1.7, 1.2-2.3). Further, the following radiological predictors were identified: time-to-imaging (OR 0.9, 0.9-1.0), early ischemic changes (OR 2.3, 1.7-3.2), and silent lesions on CT (OR 0.7, 0.5-1.0). The area under curve for this analysis was 0.85. Looking at different occlusion sites, National Institute of Health Stroke Scale and early ischemic changes on CT were independent predictors in all subgroups. Neurological deficits, stroke risk factors, and CT findings accurately identify acute ischemic stroke patients at risk of symptomatic vessel occlusion. Predicting the presence of these occlusions may impact emergency stroke care in regions with limited access to noninvasive vascular imaging.

  15. Occlusion issues in early Renaissance art

    PubMed Central

    Gillam, Barbara

    2011-01-01

    Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings. PMID:23145262

  16. Robust face alignment under occlusion via regional predictive power estimation.

    PubMed

    Heng Yang; Xuming He; Xuhui Jia; Patras, Ioannis

    2015-08-01

    Face alignment has been well studied in recent years, however, when a face alignment model is applied on facial images with heavy partial occlusion, the performance deteriorates significantly. In this paper, instead of training an occlusion-aware model with visibility annotation, we address this issue via a model adaptation scheme that uses the result of a local regression forest (RF) voting method. In the proposed scheme, the consistency of the votes of the local RF in each of several oversegmented regions is used to determine the reliability of predicting the location of the facial landmarks. The latter is what we call regional predictive power (RPP). Subsequently, we adapt a holistic voting method (cascaded pose regression based on random ferns) by putting weights on the votes of each fern according to the RPP of the regions used in the fern tests. The proposed method shows superior performance over existing face alignment models in the most challenging data sets (COFW and 300-W). Moreover, it can also estimate with high accuracy (72.4% overlap ratio) which image areas belong to the face or nonface objects, on the heavily occluded images of the COFW data set, without explicit occlusion modeling.

  17. BOLD fMRI and DTI in strabismic amblyopes following occlusion therapy.

    PubMed

    Gupta, Shikha; Kumaran, Senthil S; Saxena, Rohit; Gudwani, Sunita; Menon, Vimala; Sharma, Pradeep

    2016-08-01

    Evaluation of brain cluster activation using the functional magnetic resonance imaging (fMRI) and diffusion tensor imaging (DTI) was sought in strabismic amblyopes. In this hospital-based case-control cross-sectional study, fMRI and DTI were conducted in strabismic amblyopes before initiation of any therapy and after visual recovery following the administration of occlusion therapy. FMRI was performed in 10 strabismic amblyopic subjects (baseline group) and in 5 left strabismic amblyopic children post-occlusion therapy after two-line visual improvement. Ten age-matched healthy children with right ocular dominance formed control group. Structural and functional MRI was carried out on 1.5T MR scanner. The visual task consisted of 8 Hz flickering checkerboard with red dot and occasional green dot. Blood-oxygen-level-dependent (BOLD) fMRI was analyzed using statistical parametric mapping and DTI on NordicIce (NordicNeuroLab) softwares. Reduced occipital activation was elicited when viewing with the amblyopic eye in amblyopes. An 'ipsilateral to viewing eye' pattern of calcarine BOLD activation was observed in controls and left amblyopes. Activation of cortical areas associated with visual processing differed in relation to the viewing eye. Following visual recovery on occlusion therapy, enhanced activity in bilateral hemispheres in striate as well as extrastriate regions when viewing with either eye was seen. Improvement in visual acuity following occlusion therapy correlates with hemodynamic activity in amblyopes.

  18. Time to aortic occlusion: It's all about access.

    PubMed

    Romagnoli, Anna; Teeter, William; Pasley, Jason; Hu, Peter; Hoehn, Melanie; Stein, Deborah; Scalea, Thomas; Brenner, Megan

    2017-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less invasive method of proximal aortic occlusion compared with resuscitative thoracotomy with aortic cross-clamping (RTACC). This study compared time to aortic occlusion with REBOA and RTACC, both including and excluding time required for common femoral artery (CFA) cannulation. This was a retrospective, single-institution review of REBOA or RTACC performed between February 2013 and January 2016. Time of skin incision to aortic cross-clamp for RTACC, time required for CFA cannulation by percutaneous and open methods, and time from guide-wire insertion to balloon inflation at Zone 1 for REBOA, were obtained from videographic recordings. Eighteen RTACC and 21 REBOAs were performed. Median (Q1, Q3) time from skin incision to aortic cross-clamping was 317 seconds (227, 551 seconds). Median (Q1, Q3) time from start of arterial access to Zone 1 balloon occlusion was 474 seconds (431, 572 seconds) (vs. RTACC, p = 0.01). All REBOA procedures were performed with the same device. The median time to complete CFA cannulation was 247 seconds (range, 164-343 seconds), with no difference between percutaneous or open procedures (p = 0.07). The median (Q1, Q3) time to aortic occlusion in REBOA once arterial access had been established was 245 seconds (179, 295.5 seconds), which was significantly shorter than RTACC (p = 0.003). Once CFA access is achieved, time to aortic occlusion is faster with REBOA. Time to aortic occlusion is less than the time required to cannulate the CFA either by percutaneous or open approaches, emphasizing the importance of accurate and expedient CFA access. Resuscitative endovascular balloon occlusion of the aorta may represent a feasible alternative to thoracotomy for aortic occlusion. Time to aortic occlusion will likely decrease with the advent of newer REBOA technology. The rate-limiting portion of REBOA continues to be obtaining CFA access. Therapeutic, level V.

  19. Predictors of early stent occlusion among plastic biliary stents.

    PubMed

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  20. Evaluation of the effectiveness of a semi-finished occlusal appliance – a randomized, controlled clinical trial

    PubMed Central

    2013-01-01

    Introduction Painful temporomandibular disorders (TMDs) are usually treated with physiotherapy, self-exercises, medication-based therapy and splint therapy. For splint therapy different types of splints are available. Therefore this randomized controlled study compared the effectiveness of a semi-finished occlusal appliance (SB) with a laboratory-made occlusal appliance (SS) in myofascial pain patients. Method The trial subjects allocated to the experimental groups with the (SB) occlusal appliance and those provided with a laboratory-made occlusal appliance (SS) did, in addition, receive conservative treatment (self-exercises, drug-based and manual therapy). The control group was given conservative therapy (CO) only. Overall, a total of 63 patients participated in the study with each group consisting of 21 subjects. Results When the first follow-up examination took place (14 days after splint insertion) mouth opening within the SB group was significantly enlarged. When the second examination was conducted (2.5 months after splint insertion) mouth opening was significantly enlarged in both splint groups when compared with the initial value. In the control group, no significant enlargement of mouth opening was detected. At no point there was a significant reduction in the number of pressure-sensitive areas of the TMJ. On palpation of the masticatory muscles however, a significant reduction in the number of pressure-sensitive areas could be observed within the CO group and the SS group after 2.5 months. When comparing pain reduction (muscle/joint pain) and mouth opening, no significant differences could be detected between the treatments. Conclusion The results suggest that TMD should be treated conservatively. In cases of restricted mouth opening, the additional use of occlusal appliances can eliminate the patient’s discomfort more quickly. In this context, the tested, semi-finished occlusal appliance appears to offer an immediately available, temporary alternative

  1. Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

    PubMed Central

    Choi, Sulki

    2017-01-01

    PURPOSE The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness. PMID:29279761

  2. Temporo-mandibular joint condylectomy and its effect over occlusion in cats: cadaveric study.

    PubMed

    El-Warrak, A O; Ferrer, G A; Lanthier, T; Loureiro Silva, B; El-Warrak, L O

    2011-03-01

    To determine the effect of unilateral condylectomy on dental occlusion in cats. Twelve feline cadaver heads were randomly submitted to either a right or left unilateral condylectomy of the temporo-mandibular joint. The distance between the mandibular and maxillary canine tooth was measured before (B0) and after the unilateral condylectomy (P0). A right or left latero--lateral standardised force (4 N) was applied to the mandibular mentus area before and after the surgical procedure. These measurements were analysed with a linear model for repeated measures. The comparative analysis between pre- and postsurgical values indicated no significant variation in teeth displacement following condylectomy between B0 and P0 measurements. Statistically significant differences were detected after either left or right condylectomy with respect to all measurements after application of the standardised forces. Occlusion changes are significant when comparing bites before and after surgery. Unilateral condylectomy causes a significant increase in latero-lateral amplitude of jaw movement which might clinically affect feline dental occlusion. Clinical studies are required to determine the effect of unilateral condylectomies on mastication and dental occlusion in feline patients. © 2011 British Small Animal Veterinary Association.

  3. Modeling Thermal Contact Resistance

    NASA Technical Reports Server (NTRS)

    Kittel, Peter; Sperans, Joel (Technical Monitor)

    1994-01-01

    One difficulty in using cryocoolers is making good thermal contact between the cooler and the instrument being cooled. The connection is often made through a bolted joint. The temperature drop associated with this joint has been the subject of many experimental and theoretical studies. The low temperature behavior of dry joints have shown some anomalous dependence on the surface condition of the mating parts. There is also some doubts on how well one can extrapolate from the test samples to predicting the performance of a real system. Both finite element and analytic models of a simple contact system have been developed. The model assumes (a) the contact is dry (contact limited to a small portion of the total available area and the spaces in-between the actual contact patches are perfect insulators), (b) contacts are clean (conductivity of the actual contact is the same as the bulk), (c) small temperature gradients (the bulk conductance may be assumed to be temperature independent), (d) the absolute temperature is low (thermal radiation effects are ignored), and (e) the dimensions of the nominal contact area are small compared to the thickness of the bulk material (the contact effects are localized near the contact). The models show that in the limit of actual contact area much less than the nominal area (a much less than A), that the excess temperature drop due to a single point of contact scales as a(exp -1/2). This disturbance only extends a distance approx. A(exp 1/2) into the bulk material. A group of identical contacts will result in an excess temperature drop that scales as n(exp -1/2), where n is the number of contacts and n dot a is constant. This implies that flat rough surfaces will have a lower excess temperature drop than flat polished surfaces.

  4. Assessment of occlusion after placement of stainless steel crowns in children - a pilot study.

    PubMed

    Gallagher, S; O'Connell, B C; O'Connell, A C

    2014-10-01

    Many stainless steel crowns (SSCs) disrupt the occlusion in children, but stabilisation appears to occur within a short period post-placement. The extent and mechanism of these short-term occlusal changes in children are unknown. This study sought to determine whether placement of a SSC changes the maximum intercuspation position (MIP) in children, whether the MIP returns to normal within 4 weeks and whether local anaesthesia had an effect on the child's ability to achieve MIP. The T-Scan(®) III was used for the measurement of occlusal contacts. Reliability and reproducibility of the system was determined using a calibration exercise where MIP recordings were taken of eleven children not undergoing any dental treatment. For the main study, the percentage of total occlusal force on each tooth was recorded in 20 children preoperatively, after local anaesthesia, after SSC placement and 4 weeks postoperatively. There was no significant difference in MIP (P = 0·435) preoperatively and post-administration of local anaesthesia. There was a significant difference between the preoperative force on a tooth and the reading after crown placement (P = 0·0013, Wilcoxon test). By 4 weeks, there was no significant difference overall between post-SSC placement and the preoperative value for the tooth (P = 0·3). Administration of local anaesthesia did not affect the ability of a child to attain MIP. Maximum intercuspation position was disturbed by the placement of a SSC in seven of 20 cases. When MIP was disturbed, in most cases, it returned to preoperative status within 4 weeks of crown placement. © 2014 John Wiley & Sons Ltd.

  5. A Magnetic Microbead Occlusion Model to Induce Ocular Hypertension-Dependent Glaucoma in Mice

    PubMed Central

    Cueva Vargas, Jorge L.; Di Polo, Adriana

    2016-01-01

    The use of rodent models of glaucoma has been essential to understand the molecular mechanisms that underlie the pathophysiology of this multifactorial neurodegenerative disease. With the advent of numerous transgenic mouse lines, there is increasing interest in inducible murine models of ocular hypertension. Here, we present an occlusion model of glaucoma based on the injection of magnetic microbeads into the anterior chamber of the eye using a modified microneedle with a facetted bevel. The magnetic microbeads are attracted to the iridocorneal angle using a handheld magnet to block the drainage of aqueous humour from the anterior chamber. This disruption in aqueous dynamics results in a steady elevation of intraocular pressure, which subsequently leads to the loss of retinal ganglion cells, as observed in human glaucoma patients. The microbead occlusion model presented in this manuscript is simple compared to other inducible models of glaucoma and also highly effective and reproducible. Importantly, the modifications presented here minimize common issues that often arise in occlusion models. First, the use of a bevelled glass microneedle prevents backflow of microbeads and ensures that minimal damage occurs to the cornea during the injection, thus reducing injury-related effects. Second, the use of magnetic microbeads ensures the ability to attract most beads to the iridocorneal angle, effectively reducing the number of beads floating in the anterior chamber avoiding contact with other structures (e.g., iris, lens). Lastly, the use of a handheld magnet allows flexibility when handling the small mouse eye to efficiently direct the magnetic microbeads and ensure that there is little reflux of the microbeads from the eye when the microneedle is withdrawn. In summary, the microbead occlusion mouse model presented here is a powerful investigative tool to study neurodegenerative changes that occur during the onset and progression of glaucoma. PMID:27077732

  6. Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis.

    PubMed

    Borges Radaelli, Manuel Tomás; Idogava, Henrique Takashi; Spazzin, Aloisio Oro; Noritomi, Pedro Yoshito; Boscato, Noéli

    2018-04-30

    An occlusal device is frequently recommended for patients with bruxism to protect implant-supported restorations and prevent marginal bone loss. Scientific evidence to support this treatment is lacking. The purpose of this 3-dimensional (3D) finite element study was to evaluate the influence of an acrylic resin occlusal device, implant length, and insertion depth on stress distribution with functional and parafunctional loadings. Computer-aided design software was used to construct 8 models. The models were composed of a mandibular bone section including the second premolar and first and second molars. Insertion depths (bone level and 2 mm subcrestal) were simulated at the first molar. Three natural antagonist maxillary teeth and the placement or not of an occlusal device were simulated. Functional (200-N axial and 10-N oblique) and parafunctional (1000-N axial and 25-N oblique) forces were applied. Finite element analysis (FEA) was used to determine the maximum principal stress for the cortical and trabecular bone and von Mises for implant and prosthetic abutment. Stress concentration was observed at the abutment-implant and the implant-bone interfaces. Occlusal device placement changed the pattern of stress distribution and reduced stress levels from parafunctional loading in all structures, except in the trabecular bone. Implants with subcrestal insertion depths had reduced stress at the implant-abutment interface and cortical bone around the implant abutment, while the stress increased in the bone in contact with the implant. Parafunctional loading increased the stress levels in all structures when compared with functional loading. An occlusal device resulted in the lowest stress levels at the abutment and implant and the most favorable stress distribution between the cortical and trabecular bone. Under parafunctional loading, an occlusal device was more effective in reducing stress distribution for longer implants inserted at bone level. Subcrestally, implant

  7. Pattern of maxillary and mandibular proximal enamel thickness at the contact area of the permanent dentition from first molar to first molar.

    PubMed

    Sarig, Rachel; Vardimon, Alexander D; Sussan, Celine; Benny, Lea; Sarne, Ofer; Hershkovitz, Israel; Shpack, Nir

    2015-04-01

    Proximal enamel thickness (PET) at the mesial and distal contact areas of the complete permanent dentition has not been previously reported. Anatomic investigation of PET is essential for interproximal reduction treatment. Our objectives were to measure the PETs of the complete maxillary and mandibular dentitions at the contact areas, to compare the PETs of adjacent teeth, and to evaluate the vertical position of each contact area. We evaluated 720 extracted teeth; of these, 109 intact teeth were selected. The mesial and distal contact areas were demarcated, and each tooth was embedded in transparent epoxy resin. Blocks were prepared so that the 2 demarcated contact areas were exposed, and 6 measurements were taken and statistically analyzed. Both jaws showed the same PET pattern characterized by 5 features: PET increased progressively from incisor (0.63 mm) to first molar (1.48 mm). Per tooth, mesial and distal PET did not differ. Total maxillary (26.86 mm) and mandibular (24.52 mm) PETs were similar. Paired PETs at the interproximal interface were similar, with the exception of the lateral incisor-canine interfaces. From incisor to first molar, the contact area becomes located farther gingivally. The existing guideline of maximal 0.5-mm interproximal reduction per 2 adjacent teeth should be kept in the anterior region and could be increased to 1 mm in the posterior region, when an equal amount is removed. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Prediction of Large Vessel Occlusions in Acute Stroke: National Institute of Health Stroke Scale Is Hard to Beat.

    PubMed

    Vanacker, Peter; Heldner, Mirjam R; Amiguet, Michael; Faouzi, Mohamed; Cras, Patrick; Ntaios, George; Arnold, Marcel; Mattle, Heinrich P; Gralla, Jan; Fischer, Urs; Michel, Patrik

    2016-06-01

    Endovascular treatment for acute ischemic stroke with a large vessel occlusion was recently shown to be effective. We aimed to develop a score capable of predicting large vessel occlusion eligible for endovascular treatment in the early hospital management. Retrospective, cohort study. Two tertiary, Swiss stroke centers. Consecutive acute ischemic stroke patients (1,645 patients; Acute STroke Registry and Analysis of Lausanne registry), who had CT angiography within 6 and 12 hours of symptom onset, were categorized according to the occlusion site. Demographic and clinical information was used in logistic regression analysis to derive predictors of large vessel occlusion (defined as intracranial carotid, basilar, and M1 segment of middle cerebral artery occlusions). Based on logistic regression coefficients, an integer score was created and validated internally and externally (848 patients; Bernese Stroke Registry). None. Large vessel occlusions were present in 316 patients (21%) in the derivation and 566 (28%) in the external validation cohort. Five predictors added significantly to the score: National Institute of Health Stroke Scale at admission, hemineglect, female sex, atrial fibrillation, and no history of stroke and prestroke handicap (modified Rankin Scale score, < 2). Diagnostic accuracy in internal and external validation cohorts was excellent (area under the receiver operating characteristic curve, 0.84 both). The score performed slightly better than National Institute of Health Stroke Scale alone regarding prediction error (Wilcoxon signed rank test, p < 0.001) and regarding discriminatory power in derivation and pooled cohorts (area under the receiver operating characteristic curve, 0.81 vs 0.80; DeLong test, p = 0.02). Our score accurately predicts the presence of emergent large vessel occlusions, which are eligible for endovascular treatment. However, incorporation of additional demographic and historical information available on hospital arrival

  9. Observation and analysis of high-speed human motion with frequent occlusion in a large area

    NASA Astrophysics Data System (ADS)

    Wang, Yuru; Liu, Jiafeng; Liu, Guojun; Tang, Xianglong; Liu, Peng

    2009-12-01

    The use of computer vision technology in collecting and analyzing statistics during sports matches or training sessions is expected to provide valuable information for tactics improvement. However, the measurements published in the literature so far are either unreliably documented to be used in training planning due to their limitations or unsuitable for studying high-speed motion in large area with frequent occlusions. A sports annotation system is introduced in this paper for tracking high-speed non-rigid human motion over a large playing area with the aid of motion camera, taking short track speed skating competitions as an example. The proposed system is composed of two sub-systems: precise camera motion compensation and accurate motion acquisition. In the video registration step, a distinctive invariant point feature detector (probability density grads detector) and a global parallax based matching points filter are used, to provide reliable and robust matching across a large range of affine distortion and illumination change. In the motion acquisition step, a two regions' relationship constrained joint color model and Markov chain Monte Carlo based joint particle filter are emphasized, by dividing the human body into two relative key regions. Several field tests are performed to assess measurement errors, including comparison to popular algorithms. With the help of the system presented, the system obtains position data on a 30 m × 60 m large rink with root-mean-square error better than 0.3975 m, velocity and acceleration data with absolute error better than 1.2579 m s-1 and 0.1494 m s-2, respectively.

  10. A pressure plate study on fore and hindlimb loading and the association with hoof contact area in sound ponies at the walk and trot.

    PubMed

    Oosterlinck, M; Pille, F; Back, W; Dewulf, J; Gasthuys, F

    2011-10-01

    The aim of this study was to evaluate the association between fore- and hind-hoof contact area and limb loading. Data from a previous study on forelimb loading and symmetry were compared with data on hindlimb kinetics, and the fore- and hind-hoof contact area at the walk and trot was evaluated. Five sound ponies, selected for symmetrical feet, were walked and trotted over a pressure plate embedded in a custom-made runway. The hindlimb peak vertical force (PVF) and vertical impulse (VI) were found to be significantly lower than in the forelimb, whereas their high symmetry ratios (>95%) did not show a significant difference from forelimb data. Hindlimb PVF in ponies was found to be slightly higher when compared to data reported for horses even though the ponies moved at a similar or lower relative velocity. The contact area had low intra-individual variability and was significantly smaller in the hind- than in the fore-hooves. A larger contact area was significantly associated with lower peak vertical pressure (PVP) but higher PVF and VI. No significant differences between left and right sides were found for contact area or loading variables. Pressure plate measurements demonstrated a significant association between hoof contact area and limb loading, in addition to intrinsic differences between fore and hindlimb locomotor function. The pressure plate provides the clinician with a tool to quantify simultaneously contralateral differences in hoof contact area and limb loading. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Dynamic Modelling of Tooth Deformation Using Occlusal Kinematics and Finite Element Analysis.

    PubMed

    Benazzi, Stefano; Nguyen, Huynh Nhu; Kullmer, Ottmar; Kupczik, Kornelius

    2016-01-01

    Dental biomechanics based on finite element (FE) analysis is attracting enormous interest in dentistry, biology, anthropology and palaeontology. Nonetheless, several shortcomings in FE modeling exist, mainly due to unrealistic loading conditions. In this contribution we used kinematics information recorded in a virtual environment derived from occlusal contact detection between high resolution models of an upper and lower human first molar pair (M1 and M1, respectively) to run a non-linear dynamic FE crash colliding test. MicroCT image data of a modern human skull were segmented to reconstruct digital models of the antagonistic right M1 and M1 and the dental supporting structures. We used the Occlusal Fingerprint Analyser software to reconstruct the individual occlusal pathway trajectory during the power stroke of the chewing cycle, which was applied in a FE simulation to guide the M1 3D-path for the crash colliding test. FE analysis results showed that the stress pattern changes considerably during the power stroke, demonstrating that knowledge about chewing kinematics in conjunction with a morphologically detailed FE model is crucial for understanding tooth form and function under physiological conditions. Results from such advanced dynamic approaches will be applicable to evaluate and avoid mechanical failure in prosthodontics/endodontic treatments, and to test material behavior for modern tooth restoration in dentistry. This approach will also allow us to improve our knowledge in chewing-related biomechanics for functional diagnosis and therapy, and it will help paleoanthropologists to illuminate dental adaptive processes and morphological modifications in human evolution.

  12. Volumetric ambient occlusion for real-time rendering and games.

    PubMed

    Szirmay-Kalos, L; Umenhoffer, T; Toth, B; Szecsi, L; Sbert, M

    2010-01-01

    This new algorithm, based on GPUs, can compute ambient occlusion to inexpensively approximate global-illumination effects in real-time systems and games. The first step in deriving this algorithm is to examine how ambient occlusion relates to the physically founded rendering equation. The correspondence stems from a fuzzy membership function that defines what constitutes nearby occlusions. The next step is to develop a method to calculate ambient occlusion in real time without precomputation. The algorithm is based on a novel interpretation of ambient occlusion that measures the relative volume of the visible part of the surface's tangent sphere. The new formula's integrand has low variation and thus can be estimated accurately with a few samples.

  13. Enhancing the magnetic anisotropy energy by tuning the contact areas of Ag and Ni at the Ag/Ni interface.

    PubMed

    Chow, Yu-Ting; Jiang, Bin-Han; Chang, Cheng-Hsun-Tony; Tsay, Jyh-Shen

    2018-01-17

    Modifying the interfacial conditions of magnetic layers by capping with overlayers can efficiently enhance the magnetic functionality of a material. However, the mechanisms responsible for this are closely related to the crystalline structure, compositional combinations, and interfacial quality, and are generally complex. In this contribution, we explored the use of Ag ultrathin overlayers on annealed . A method for preparing magnetic layers with different levels of enhanced magnetic anisotropy energy was developed. The method essentially involves simply modifying the contact area of the metallic/magnetic interface. A rougher interface results in a larger contact area between the Ag and Ni layers, resulting in an increase in magnetic anisotropy energy. Moreover, post-annealing treatments led to the segregation of Ni atoms, thus making the enhancement in the coercive force even more efficient. A model permits an understanding of the contact area and a strategy for enhancing the magnetic anisotropy energy and the coercive force was developed. Our approaches and the developed model promise to be helpful in terms of developing potential applications of ultrathin magnetic layers in the area of spintronics.

  14. Occlusion and rupture of ex vivo capillary bifurcation due to acoustic droplet vaporization

    NASA Astrophysics Data System (ADS)

    Feng, Yi; Qin, Dui; Zhang, Jun; Zhang, Lei; Bouakaz, Ayache; Wan, Mingxi

    2018-06-01

    Gas embolotherapy (GE) consists in the occlusion of tumor blood vessels using gas emboli induced by acoustic droplet vaporization (ADV), to create tumor starvation and localized drug delivery. Therefore, the occlusion and rupture of capillary bifurcation due to ADV was investigated in an ex vivo rat mesentery model using a confocal acousto-optical high-speed microscope system. Following ADV bubble formation, coalescence, and translational movement, the growing bubbles lodged in and then occluded two different capillary bifurcations. Capillary rupture was induced at the bubble lodging area, immediately followed by gas extravasation and bubble dislodging. Before and after bubble lodgment/occlusion, a local microvessel invagination was observed due to the interactions between ADV bubbles and the microvessel itself, indicating a contribution to the capillary rupture. Understanding the transient dynamics of ADV bubble, the bubble-microvessel interaction and the consequent mechanical bio-effects in GE is of the paramount importance for developing and applying this approach in clinical practice.

  15. Dental cervical lesions associated with occlusal erosion and attrition.

    PubMed

    Khan, F; Young, W G; Shahabi, S; Daley, T J

    1999-09-01

    Acid demineralization of teeth causes occlusal erosion and attrition, and shallow and wedge-shaped cervical lesions putatively involving abfraction. From 250 patients with tooth wear, 122 with cervical lesions were identified. From epoxy resin replicas of their dentitions, associations of occlusal attrition or erosion or no wear with cervical lesions were recorded at 24 tooth sites (total 2928 sites). Criteria used to discriminate occlusal attrition from erosion, and shallow from grooved, wedge-shaped or restored cervical lesions were delineated by scanning electron microscopy. A 96 per cent association was found between occlusal and cervical pathology. Shallow cervical lesions were more commonly found in association with occlusal erosion. Wedge-shaped lesions were found equally commonly in association with occlusal erosion, as with attrition. Grooved and restored cervical lesions were uncommon. Differences were appreciated in the associations within incisor, canine, premolar and molar tooth sites which related more to the site-specificity of dental erosion than to attrition from occlusal forces. Non-carious lesions on teeth then have multifactorial aetiology and pathogenesis in which erosion and salivary protection play central roles. Dentists should primarily consider erosion in the diagnosis, prevention and treatment of tooth wear.

  16. Natural (Mineral, Vegetable, Coconut, Essential) Oils and Contact Dermatitis.

    PubMed

    Verallo-Rowell, Vermén M; Katalbas, Stephanie S; Pangasinan, Julia P

    2016-07-01

    Natural oils include mineral oil with emollient, occlusive, and humectant properties and the plant-derived essential, coconut, and other vegetable oils, composed of triglycerides that microbiota lipases hydrolyze into glycerin, a potent humectant, and fatty acids (FAs) with varying physico-chemical properties. Unsaturated FAs have high linoleic acid used for synthesis of ceramide-I linoleate, a barrier lipid, but more pro-inflammatory omega-6:-3 ratios above 10:1, and their double bonds form less occlusive palisades. VCO FAs have a low linoleic acid content but shorter and saturated FAs that form a more compact palisade, more anti-inflammatory omega-6:-3 ratio of 2:1, close to 7:1 of olive oil, which disrupts the skin barrier, otherwise useful as a penetration enhancer. Updates on the stratum corneum illustrate how this review on the contrasting actions of NOs provide information on which to avoid and which to select for barrier repair and to lower inflammation in contact dermatitis genesis.

  17. Performance of experienced dentists in Switzerland after an e-learning program on ICDAS occlusal caries detection.

    PubMed

    Rodrigues, Jonas Almeida; de Oliveira, Renata Schlesner; Hug, Isabel; Neuhaus, Klaus; Lussi, Adrian

    2013-08-01

    This study aimed to evaluate the effect of an e-learning program on the validity and reproducibility of the International Caries Detection and Assessment System (ICDAS) in detecting occlusal caries. For the study, 170 permanent molars were selected. Four dentists in Switzerland who had no previous contact with ICDAS examined the teeth before and after the e-learning program and scored the sites according to ICDAS. Teeth were histologically prepared and assessed for caries extension. The significance level was set at 0.05. Sensitivity before and after the e-learning program was 0.80 and 0.77 (D1), 0.72 and 0.63 (D2), and 0.74 and 0.67 (D3,4), respectively. Specificity was 0.64 and 0.69 (D1), 0.70 and 0.81 (D2), and 0.81 and 0.87 (D3,4). A McNemar test did not show any difference between the values of sensitivity, specificity, accuracy, and area under the ROC curve (AUC) before and after the e-learning program. The averages of wK values for interexaminer reproducibility were 0.61 (before) and 0.66 (after). Correlation with histology presented wK values of 0.62 (before) and 0.63 (after). A Wilcoxon test showed a statistically significant difference between before and after the e-learning program. In conclusion, even though ICDAS performed well in detecting occlusal caries, the e-learning program did not have any statistically significant effect on its performance by these experienced dentists.

  18. Schottky Barrier Height of Pd/MoS2 Contact by Large Area Photoemission Spectroscopy.

    PubMed

    Dong, Hong; Gong, Cheng; Addou, Rafik; McDonnell, Stephen; Azcatl, Angelica; Qin, Xiaoye; Wang, Weichao; Wang, Weihua; Hinkle, Christopher L; Wallace, Robert M

    2017-11-08

    MoS 2 , as a model transition metal dichalcogenide, is viewed as a potential channel material in future nanoelectronic and optoelectronic devices. Minimizing the contact resistance of the metal/MoS 2 junction is critical to realizing the potential of MoS 2 -based devices. In this work, the Schottky barrier height (SBH) and the band structure of high work function Pd metal on MoS 2 have been studied by in situ X-ray photoelectron spectroscopy (XPS). The analytical spot diameter of the XPS spectrometer is about 400 μm, and the XPS signal is proportional to the detection area, so the influence of defect-mediated parallel conduction paths on the SBH does not affect the measurement. The charge redistribution by Pd on MoS 2 is detected by XPS characterization, which gives insight into metal contact physics to MoS 2 and suggests that interface engineering is necessary to lower the contact resistance for the future generation electronic applications.

  19. Vehicle Detection with Occlusion Handling, Tracking, and OC-SVM Classification: A High Performance Vision-Based System

    PubMed Central

    Velazquez-Pupo, Roxana; Sierra-Romero, Alberto; Torres-Roman, Deni; Shkvarko, Yuriy V.; Romero-Delgado, Misael

    2018-01-01

    This paper presents a high performance vision-based system with a single static camera for traffic surveillance, for moving vehicle detection with occlusion handling, tracking, counting, and One Class Support Vector Machine (OC-SVM) classification. In this approach, moving objects are first segmented from the background using the adaptive Gaussian Mixture Model (GMM). After that, several geometric features are extracted, such as vehicle area, height, width, centroid, and bounding box. As occlusion is present, an algorithm was implemented to reduce it. The tracking is performed with adaptive Kalman filter. Finally, the selected geometric features: estimated area, height, and width are used by different classifiers in order to sort vehicles into three classes: small, midsize, and large. Extensive experimental results in eight real traffic videos with more than 4000 ground truth vehicles have shown that the improved system can run in real time under an occlusion index of 0.312 and classify vehicles with a global detection rate or recall, precision, and F-measure of up to 98.190%, and an F-measure of up to 99.051% for midsize vehicles. PMID:29382078

  20. Relationship between femoroacetabular contact areas and hip position in the normal joint: an in vitro evaluation.

    PubMed

    Signorelli, Cecilia; Lopomo, Nicola; Bonanzinga, Tommaso; Marcheggiani Muccioli, Giulio Maria; Safran, Marc R; Marcacci, Maurilio; Zaffagnini, Stefano

    2013-02-01

    Different approaches have been proposed to diagnose femoroacetabular impingement (FAI) condition and hip instability. It is still debatable which test is the most effective to make a correct diagnosis. The true mechanics of the hip during particular physical examination manoeuvres is unknown. Eight fresh frozen hips were passively taken through 3 different commonly used positions for FAI diagnosis and hip instability: 90° Flexion-Adduction-Internal Rotation, Hyperextension-Adduction-External Rotation and Hyperextension-Neutral-External Rotation. Kinematics and anatomical data were acquired by an optoelectronic system. The contact areas between acetabulum and femoral head were analysed to determine whether these tests are able to localize regions of the hip that may give patients pain. In the hip positions where the femur was in Hyperextension-External Rotation, the contact area was mainly concentrated in the posterosuperior area of the acetabulum, while during 90° Flexion-Adduction-Internal Rotation position, there was a wider distribution of contact, not specific to the anterolateral acetabulum. The results confirm the ability of the Hyperextension-External Rotation tests to particularly analyse the posterior region of the acetabulum. Placing the hip in 90° of Flexion-Adduction-Internal Rotation allows for testing a wider zone of the acetabulum and is not specific to abutment of the femoral head-neck region against the anterolateral acetabulum.

  1. Part-time occlusion therapy for amblyopia in older children

    PubMed Central

    Singh, Inderpreet; Sachdev, Nishant; Kaushik, Sushmita

    2008-01-01

    Aim: To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Materials and Methods: Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Statistical Analysis: Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. Results: All four groups showed significant visual improvement after 18 weeks of occlusion therapy (P<0.001). Seventy-three (73%) of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups (P=0.083). However, in severe amblyopia (vision 20/100 or worse), six hours (P=0.048) and full-time occlusion (P=0.027) treatment were significantly more effective than two hours occlusion. Conclusion: All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy. PMID:18974515

  2. Part-time occlusion therapy for amblyopia in older children.

    PubMed

    Singh, Inderpreet; Sachdev, Nishant; Brar, Gagandeep S; Kaushik, Sushmita

    2008-01-01

    To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. All four groups showed significant visual improvement after 18 weeks of occlusion therapy ( P < 0.001). Seventy-three (73%) of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups ( P =0.083). However, in severe amblyopia (vision 20/100 or worse), six hours ( P =0.048) and full-time occlusion ( P =0.027) treatment were significantly more effective than two hours occlusion. All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy.

  3. Occlusal plane location in edentulous patients: a review.

    PubMed

    Shetty, Sanath; Zargar, Nazia Majeed; Shenoy, Kamalakanth; Rekha, V

    2013-09-01

    Occlusal plane orientation is an important factor in the construction of a complete denture. Occlusal plane could be oriented using landmarks in the mandibular arch as well as in the maxillary arch. In the mandibular arch there are few landmarks which could be used to orient the occlusal plane like the retromolar pad, corner of the lips (lower lip length) whereas the maxillary arch has a number of landmarks, of which the ala-tragal line is the most commonly used and the same being the most controversial. In the following article different landmarks and its accuracy for orientating the occlusal plane in an edentulous subject as studied by various authors has been discussed.

  4. Osteogenesis imperfecta with right renal artery occlusion

    PubMed Central

    Vaish, Arvind Kumar; Kumar, Nitin; Jain, Nirdesh; Agarwal, Abhishek

    2012-01-01

    We here report a case of osteogenesis imperfecta who presented with severe hypertension and left ventricular failure and had right renal artery occlusion. The case is very interesting as renal artery occlusion has not been reported earlier in osteogenesis imperfecta. PMID:22962392

  5. Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jambon, E.; Petitpierre, F.; Brizzi, V.

    PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomesmore » and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.« less

  6. Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas

    PubMed Central

    2013-01-01

    Background Cuff electrodes have been widely used chronically in different clinical applications. This neural interface has been dominantly used for nerve stimulation while interfering noise is the major issue when employed for recording purposes. Advancements have been made in rejecting extra-neural interference by using continuous ring contacts in tripolar topologies. Ring contacts provide an average of the neural activity, and thus reduce the information retrieved. Splitting these contacts into smaller recording areas could potentially increase the information content. In this study, we investigate the impact of such discretization on the Signal-to-Noise Ratio (SNR). The effect of contacts positioning and an additional short circuited pair of electrodes were also addressed. Methods Different recording configurations using ring, dot, and a mixed of both contacts were studied in vitro in a frog model. An interfering signal was induced in the medium to simulate myoelectric noise. The experimental setup was design in such a way that the only difference between recordings was the configuration used. The inter-session experimental differences were taken care of by a common configuration that allowed normalization between electrode designs. Results It was found that splitting all contacts into small recording areas had negative effects on noise rejection. However, if this is only applied to the central contact creating a mixed tripole configuration, a considerable and statistically significant improvement was observed. Moreover, the signal to noise ratio was equal or larger than what can be achieved with the best known configuration, namely the short circuited tripole. This suggests that for recording purposes, any tripole topology would benefit from splitting the central contact into one or more discrete contacts. Conclusions Our results showed that a mixed tripole configuration performs better than the configuration including only ring contacts. Therefore, splitting

  7. Near-infrared diffuse reflectance imaging of infarct core and peri-infarct depolarization in a rat middle cerebral artery occlusion model

    NASA Astrophysics Data System (ADS)

    Kawauchi, Satoko; Nishidate, Izumi; Nawashiro, Hiroshi; Sato, Shunichi

    2014-03-01

    To understand the pathophysiology of ischemic stroke, in vivo imaging of the brain tissue viability and related spreading depolarization is crucial. In the infarct core, impairment of energy metabolism causes anoxic depolarization (AD), which considerably increases energy consumption, accelerating irreversible neuronal damage. In the peri-infarct penumbra region, where tissue is still reversible despite limited blood flow, peri-infarct depolarization (PID) occurs, exacerbating energy deficit and hence expanding the infarct area. We previously showed that light-scattering signal, which is sensitive to cellular/subcellular structural integrity, was correlated with AD and brain tissue viability in a rat hypoxia-reoxygenation model. In the present study, we performed transcranial NIR diffuse reflectance imaging of the rat brain during middle cerebral artery (MCA) occlusion and examined whether the infarct core and PIDs can be detected. Immediately after occluding the left MCA, light scattering started to increase focally in the occlusion site and a bright region was generated near the occlusion site and spread over the left entire cortex, which was followed by a dark region, showing the occurrence of PID. The PID was generated repetitively and the number of times of occurrence in a rat ranged from four to ten within 1 hour after occlusion (n=4). The scattering increase in the occlusion site was irreversible and the area with increased scattering expanded with increasing the number of PIDs, indicating an expansion of the infarct core. These results suggest the usefulness of NIR diffuse reflectance signal to visualize spatiotemporal changes in the infarct area and PIDs.

  8. Comparison Between Bandage Contact Lenses and Pressure Patching on the Erosion Area and Pain Scale in Patients With Corneal Erosion.

    PubMed

    Triharpini, Ni Nyoman; Gede Jayanegara, I Wayan; Handayani, Ariesanti Tri; Widiana, I Gde Raka

    2015-01-01

    Corneal erosion is common in eye emergency cases. Extensive corneal erosions result in severe pain and prolonged healing time. This study aimed to compare bandage contact lenses with pressure patching in terms of reducing the size of the erosion area, pain scale in patients with corneal erosion and its complications. A randomized open-label clinical trial was conducted. Subjects with mechanical corneal erosion were selected to use either bandage contact lenses or pressure patching. All subjects received antibiotic eye drops and 0.5% tropicamide eye drops. Evaluations were done 24 and 72 hours after treatment. The size of the corneal erosion area, pain scale, and complications were assessed. A total of 32 eyes (16 eyes in each group) were studied. The change in the size of the corneal erosion area was greater in the bandage contact lens group than in the pressure patching group, although there was no significant difference. In the bandage contact lens group, 56.25% of the eyes were healed at 24 hours and 43.75% were healed at 72 hours. In the pressure patching group, 62.50% were healed at 24 hours and 12.50% were healed at 72 hours. The change in pain scale was significantly greater in the bandage contact lens group than in the pressure patching group. No complications were found in both groups. Bandage contact lenses are an effective alternative to treating mechanical corneal erosion because of their effect in reducing pain without causing any complications.

  9. [Perivenular whitening in central retinal vein occlusion demonstrated by "en-face" OCT].

    PubMed

    Marc, C; Gire, J; Boulicot, C; Guigou, S

    2013-10-01

    We report the case of a patient with a central vein occlusion associated with perivenular whitening. The "en-face" spectral domain OCT precisely demonstrated the ischemic area. This case underscores the utility of the "en-face" mode in the follow-up CRVO. Copyright © 2013. Published by Elsevier Masson SAS.

  10. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vessel occlusion transducer. 870.2890 Section 870.2890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion...

  11. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel occlusion transducer. 870.2890 Section 870.2890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion...

  12. Bony contact area and displacement of the temporomandibular joint after high-oblique and bilateral sagittal split osteotomy: a computer-simulated comparison.

    PubMed

    Möhlhenrich, Stephan Christian; Kamal, Mohammad; Peters, Florian; Fritz, Ulrike; Hölzle, Frank; Modabber, Ali

    2016-04-01

    The most common way to move the mandible during orthognathic surgery is by bilateral sagittal split osteotomy (BSSO). The high-oblique sagittal split osteotomy (HSSO) is an alternative, although its use is limited by potential complications, mainly to do with the position of the condyle and reduced contact with bone. The aim of this study was to find out the optimal intercondylar distance and area of contact with the surface of the bone for mandibular advancement and setback in BSSO and HSSO. Data from computed tomographic (CT) images from 40 patients were loaded into special planning software, and virtual operations done for mandibular advancement and setback at 3, 5, 8, and 10mm using BSSO and HSSO, which resulted in 640 individual mandibular displacements. The resultant area of bony contact and intercondylar distance were calculated by the software. The mean (SD) areas of contact with the bony surface after 10mm advancement for HSSO and BSSO were 193.94 (63.76) mm(2) and 967.92 (229.21) mm(2), respectively, and after 10mm setback 202.64 (62.30) mm(2) and 1108.86 (247.38) mm(2). The mean corresponding intercondylar distance after maximum advancement were 86.76 (6.40) mm and 86.59 (6.24) mm, and after maximum setback 74.90 (5.73) mm and 73.06 (6.06) mm. There were significant differences between the two for the area of contact with the surface at each displacement distance (p<0.001), but not for intercondylar distance. A larger area of bony contact can be expected at any displacement distance for BSSO, so the changes in intercondylar distance should not be considered when deciding which osteotomy to select. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Morpho-histological assessment of the periodontal support structures under the action of excessive occlusal forces and under the influence of nicotine.

    PubMed

    Ispas, Ana; Mihu, Carmen Mihaela; Crăciun, Antarinia Maria; Constantiniuc, Mariana

    2018-01-01

    Smoking and occlusal trauma are two factors that can interfere with bone homeostasis. The aim of this study was to evaluate the histocellular changes occurring in the periodontal ligament and alveolar bone during the action of excessive occlusal forces, and to assess the influence of nicotine on the alveolar bone loss in teeth subjected to occlusal trauma. Fifty-six Wistar rats were randomized into seven groups (n=8). Animals were exposed to nicotine and occlusal trauma for 7, 14 and 30 days. Three groups were exposed to occlusal trauma alone, another three groups were exposed to occlusal trauma and nicotine, and one group was not exposed to any treatment. Periodontal lesions induced in the first stage (7-14 days) manifested by a moderate increase of the periodontal space, a multiplication, thickening and elongation of periodontal fibers, as well as their condensation in the middle area of the periradicular space. Regarding bone changes induced by occlusal trauma, groups 5 and 7 (occlusal trauma and nicotine administration) had higher bone losses compared to groups 1, 2, 3, 4 and 6. This study demonstrated that nicotine significantly affected the alveolar bone. The induced occlusal trauma caused obvious tissue damage. At the same time, it was found that nicotine enhanced alveolar bone resorption, increased tooth mobility and induced an exacerbation of inflammatory processes.

  14. How Dutch orthoptists deal with noncompliance with occlusion therapy for amblyopia.

    PubMed

    Tjiam, A M; Vukovic, E; Asjes-Tydeman, W L; Holtslag, G; Loudon, S E; Sinoo, M M; Simonsz, H J

    2010-12-01

    We previously found that compliance with occlusion therapy for amblyopia is poor, especially among children of non-native parents who spoke Dutch poorly and who were low educated. We investigated conception, awareness, attitude, and actions to deal with noncompliance among Dutch orthoptists. Orthoptists working in non-native, low socioeconomic status (SES) areas and a selection of orthoptists working elsewhere in the Netherlands were studied. They were observed in their practice, received a structured questionnaire, and underwent a semi-structured interview. Finally, a short survey was sent to all working orthoptists in the Netherlands. Nine orthoptists working in non-native, low-SES areas and 23 working elsewhere in the Netherlands participated. One hundred and fifty-one orthoptists returned the short survey. Major discrepancies existed in conception, awareness, and attitude. Opinions differed on what should be defined as noncompliance and on what causes noncompliance. Some orthoptists found noncompliance annoying, unpleasant, and hard to imagine, others were more understanding. Many pitied the noncompliant child. Almost all thought that the success of occlusion therapy lies both with the parents and the orthoptist, but one third thought that noncompliance was not solely their responsibility. Patients' compliance was estimated at 69.3% in non-native, low-SES areas (electronically, 52% had been measured), at 74.1% by the other 23 orthoptists, and at 73.8% in the short survey. Actions to improve compliance were diverse; some increased occlusion hours whereas others decreased them. In non-native, low-SES areas, 22% spoke Dutch moderately to none; the allotted time for a patient's first visit was 21'; the time spent on explaining to the parents was 2'30" and to the child 10". In practices of the other 23 orthoptists, 6% spoke Dutch moderately to none (P<0.0001), the time for a patient's first visit was 27'24" (P=0.47), and the periods spent explaining were 2'51" (P=0

  15. Long-term occlusal changes assessed by the American Board of Orthodontics' model grading system.

    PubMed

    Aszkler, Robert M; Preston, Charles B; Saltaji, Humam; Tabbaa, Sawsan

    2014-02-01

    The purpose of this study was to assess the long-term posttreatment changes in all criteria of the American Board of Orthodontics' (ABO) model grading system. We used plaster models from patients' final and posttreatment records. Thirty patients treated by 1 orthodontist using 1 bracket prescription were selected. An initial discrepancy index for each subject was performed to determine the complexity of each case. The final models were then graded using the ABO's model grading system immediately at posttreatment and postretention. Statistical analysis was performed on the 8 criteria of the model grading system, including paired t tests and Pearson correlations. An alpha of 0.05 was considered statistically significant. The average length of time between the posttreatment and postretention records was 12.7 ± 4.4 years. It was shown that alignment and rotations worsened by postretention (P = 0.014), and a weak statistically significant correlation at posttreatment and postretention was found (0.44; P = 0.016). Both marginal ridges and occlusal contacts scored less well at posttreatment. These criteria showed a significant decrease in scores between posttreatment and postretention (P <0.001), but the correlations were not statistically significant. The average total score showed a significant decrease between posttreatment and postretention (P <0.001), partly because of the large decrease in the previous 2 criteria. Higher scores for occlusal contacts and marginal ridges were found at the end of treatment; however, those scores and the overall scores for the 30 subjects improved in the postretention phase. Copyright © 2014. Published by Mosby, Inc.

  16. Does compliance with amblyopia management improve following supervised occlusion treatment?

    PubMed

    El-Ghrably, I A; Longville, D; Gnanaraj, L

    2007-01-01

    To demonstrate improvement in compliance following supervised occlusion therapy for amblyopia in children who had failed to respond to outpatient treatment. Retrospective review of the visual outcome of 30 children who were admitted to an ophthalmology ward for 1-day intensive supervised occlusion. These children had documented poor compliance and previously failed to respond to the outpatient occlusion treatment. During their stay a trained ophthalmology nurse educated parents regarding amblyopia and the benefits of occlusion therapy. Visual acuity (VA) of the amblyopic and fellow eyes was recorded on admission, discharge, and at each subsequent visit. The compliance was recorded from parent's history and also indirectly by noticing improvement in vision. The mean supervised occlusion was 7.4 hours (range 4-12 hours). The compliance with occlusion therapy improved in 23 children (77%) after discharge. The mean duration of occlusion after discharge improved to 4 hours (range 1-12 hours). The mean follow-up was 18 months (range 4-24 months). Though there was no dramatic improvement in VA at discharge there was a statistically significant improvement in VA between admission and last recorded VA (p<0.0001). Of the 23 children who were compliant with occlusion following discharge, 21 (91%) gained at least one line of acuity in their amblyopic eye on the last assessment of their VA and five of them achieved 6/12. Of the seven children who did not comply with occlusion following discharge, only one patient gained one line improvement in his amblyopic eye. This study shows that supervised occlusion treatment and parental education was effective in children who had initially failed traditional outpatient treatment.

  17. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  18. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  19. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  20. In vitro reproduction of incisal/occlusal cupping/cratering.

    PubMed

    Dzakovich, John J; Oslak, Robert R

    2013-06-01

    Occlusal cupping/cratering (depressed dentin surrounded by elevated rims of enamel) has been postulated to be the result of abrasion, bruxism, attrition, acid erosion, stress corrosion, or a combination of these. The primary etiology or the multifactorial sequence of occlusal cupping/cratering remains scientifically unsubstantiated. The purpose of this study was to reproduce occlusal/incisal cupping/cratering in vitro. This study was designed to create cupping/cratering on the occlusal surfaces of extracted human teeth rather than to quantify the amount of lost tooth structure caused by abrasion. One name-brand toothbrush was tested with 2 different dentifrices (of different abrasive potentials [low and high]) and water only (nonabrasive) on extracted human teeth. Six specimens of 4 teeth each (24 teeth) were subjected to horizontal brushing in a 1:1 toothpaste/water slurry and water only. The control group, brushed with water only, demonstrated no visible loss of tooth structure. Each of the specimens brushed with toothpaste, regardless of the degree of abrasivity, demonstrated visible wear of the dentin, resulting in occlusal/incisal cupping/cratering. Pronounced cupping/cratering was caused by horizontal brushing with commercial toothpastes. Brushing in water demonstrated no visual loss of occlusal tooth structure. (J Prosthet Dent 2013;109:384-391). Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Endovascular Treatment of Veno-Occlusive Behcet's Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tekbas, Guven, E-mail: drgtekbas@gmail.com; Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Gur, Serkan, E-mail: mserkangur@yahoo.com

    Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet's disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18-76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd-Chiari syndrome (BCS; n = 2).more » All patients met criteria of the International Study Group on Behcet's Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.« less

  2. Compliance with occlusion therapy for childhood amblyopia.

    PubMed

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2013-09-17

    Explore compliance with occlusion treatment of amblyopia in the Monitored and Randomized Occlusion Treatment of Amblyopia Studies (MOTAS and ROTAS), using objective monitoring. Both studies had a three-phase protocol: initial assessment, refractive adaptation, and occlusion. In the occlusion phase, participants were instructed to dose for 6 hours/day (MOTAS) or randomized to 6 or 12 hour/day (ROTAS). Dose was monitored continuously using an occlusion dose monitor (ODM). One hundred and fifty-two patients (71 male, 81 female; 122 Caucasian, 30 non-Caucasian) of mean ± SD age 68 ± 18 months participated. Amblyopia was defined as an interocular acuity difference of at least 0.1 logMAR and was associated with anisometropia in 50, strabismus in 44, and both (mixed) in 58. Median duration of occlusion was 99 days (interquartile range 72 days). Mean compliance was 44%, mean proportion of days with no patch worn was 42%. Compliance was lower (39%) on weekends compared with weekdays (46%, P = 0.04), as was the likelihood of dosing at all (52% vs. 60%, P = 0.028). Compliance was lower when attendance was less frequent (P < 0.001) and with prolonged treatment duration (P < 0.001). Age, sex, amblyopia type, and severity were not associated with compliance. Mixture modeling suggested three subpopulations of patch day doses: less than 30 minutes; doses that achieve 30% to 80% compliance; and doses that achieve around 100% compliance. This study shows that compliance with patching treatment averages less than 50% and is influenced by several factors. A greater understanding of these influences should improve treatment outcome. (ClinicalTrials.gov number, NCT00274664).

  3. Melorheostosis with occlusion of dorsalis pedis artery.

    PubMed

    Ishibe, Motomi; Inoue, Masayuki; Saitou, Katsutoshi

    2002-02-01

    Melorheostosis is an unusual sclerotic dysplasia of bone. The case of a 51-year-old female patient with melorheostosis and occlusion of the dorsalis pedis artery is described. Although numerous vascular anomalies have been noted in patients with melorheostosis, occlusion of the dorsalis pedis artery has not been reported previously.

  4. Effects of mid-foot contact area ratio on lower body kinetics/kinematics in sagittal plane during stair descent in women.

    PubMed

    Lee, Jinkyu; Hong, Yoon No Gregory; Shin, Choongsoo S

    2016-07-01

    The mid-foot contact area relative to the total foot contact area can facilitate foot arch structure evaluation. A stair descent motion consistently provides initial fore-foot contact and utilizes the foot arch more actively for energy absorption. The purpose of this study was to compare ankle and knee joint angle, moment, and work in sagittal plane during stair descending between low and high Mid-Foot-Contact-Area (MFCA) ratio group. The twenty-two female subjects were tested and classified into two groups (high MFCA and low MFCA) using their static MFCA ratios. The ground reaction force (GRF) and kinematics of ankle and knee joints were measured while stair descending. During the period between initial contact and the first peak in vertical GRF (early absorption phase), ankle negative work for the low MFCA ratio group was 33% higher than that for the high MFCA ratio group (p<0.05). However, ankle negative work was not significantly different between the two groups during the period between initial contact and peak dorsiflexion angle (early absorption phase+late absorption phase). The peak ankle dorsiflexion angle was smaller in the low MFCA ratio group (p<0.05). Our results suggest that strategy of energy absorption at the ankle and foot differs depending upon foot arch types classified by MFCA. The low MFCA ratio group seemed to absorb more impact energy using strain in the planar fascia during early absorption phase, whereas the high MFCA ratio group absorbed more impact energy using increased dorsiflexion during late absorption phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Amalric sign: An augur of ophthalmic artery occlusion

    PubMed Central

    Hande, Prathibha; Sinha, Babi; Nayak, Shivani; Srinivasan, Srilakshmi; Shetty, Jyothi

    2017-01-01

    A 75-year-old man presented to us with sudden onset of profound vision loss in his right eye and was identified as suffering from an ophthalmic artery occlusion. Apart from the retinal whitening and box-carring of the retinal arteries, there were characteristic triangular patches of retinal whitening in the midperipheral temporal fundus indicating a previous lateral posterior choroidal artery occlusion. The patient was a chronic smoker and had dyslipidemia. The carotid Doppler study showed complete occlusion of the internal carotid artery. The presence of these triangular patches of retinal whitening or amalric sign can therefore herald a more proximal vessel occlusion. Hence such patients require evaluation on an emergency basis. The characteristic features of the patches on fluorescein angiography and indocyanine green angiography are discussed here. PMID:29044080

  6. Amalric sign: An augur of ophthalmic artery occlusion.

    PubMed

    Hande, Prathibha; Sinha, Babi; Nayak, Shivani; Srinivasan, Srilakshmi; Shetty, Jyothi

    2017-10-01

    A 75-year-old man presented to us with sudden onset of profound vision loss in his right eye and was identified as suffering from an ophthalmic artery occlusion. Apart from the retinal whitening and box-carring of the retinal arteries, there were characteristic triangular patches of retinal whitening in the midperipheral temporal fundus indicating a previous lateral posterior choroidal artery occlusion. The patient was a chronic smoker and had dyslipidemia. The carotid Doppler study showed complete occlusion of the internal carotid artery. The presence of these triangular patches of retinal whitening or amalric sign can therefore herald a more proximal vessel occlusion. Hence such patients require evaluation on an emergency basis. The characteristic features of the patches on fluorescein angiography and indocyanine green angiography are discussed here.

  7. The anterior component of occlusal force revisited: direct measurement and theoretical considerations.

    PubMed

    Al Qassar, Sarmad S Salih; Mavragani, Maria; Psarras, Vasilis; Halazonetis, Demetrios J

    2016-04-01

    The anterior component of occlusal force (ACF), considered to result from the mesial inclination of teeth relative to the occlusal plane, has been estimated by indirectly measuring contact point tightness (CPT) through interproximal insertion of metal strips. ACF has been observed concurrently with a posterior component, whose theoretical origin is difficult to explain. Evaluate ACF by measuring CPT directly, and integrate current data to propose a theoretical basis for ACF. The sample comprised 14 females (age: 22.3±2.8) and 16 males (age: 20.8±2.5). Our device consisted of two force sensors: one for measuring maximum bite force (MBF) (overall thickness: 4mm), and one for measuring CPT directly (0.2mm thick), inserted between the lower first molar and second premolar. ACF was computed as the difference in CPT between the biting (at 75 per cent of MBF) and non-biting conditions. Averages of MBF, CPT, and ACF were 666.67 [standard deviation (SD): 36.06], 6.74 (SD: 1.17), and 20.59 (SD: 4.60) N, respectively. ACF, CPT, and MBF were higher in males by approximately 28, 18 and 7 per cent, respectively. A positive correlation was observed between ACF and MBF (R (2): 0.64). CPT was also significantly correlated to MBF (R (2): 0.40). Biomechanical analysis indicates that previously offered explanations do not unriddle the concurrent increase of CPT at anterior and posterior contact points. ACF was related to bite force by a logarithmic model. We speculate that CPT increases during biting through a combination of mesial tipping of teeth and mandibular bending. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  8. Tracking with occlusions via graph cuts.

    PubMed

    Papadakis, Nicolas; Bugeau, Aurélie

    2011-01-01

    This work presents a new method for tracking and segmenting along time-interacting objects within an image sequence. One major contribution of the paper is the formalization of the notion of visible and occluded parts. For each object, we aim at tracking these two parts. Assuming that the velocity of each object is driven by a dynamical law, predictions can be used to guide the successive estimations. Separating these predicted areas into good and bad parts with respect to the final segmentation and representing the objects with their visible and occluded parts permit handling partial and complete occlusions. To achieve this tracking, a label is assigned to each object and an energy function representing the multilabel problem is minimized via a graph cuts optimization. This energy contains terms based on image intensities which enable segmenting and regularizing the visible parts of the objects. It also includes terms dedicated to the management of the occluded and disappearing areas, which are defined on the areas of prediction of the objects. The results on several challenging sequences prove the strength of the proposed approach.

  9. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures.

    PubMed

    Aguilar, F G; Drubi-Filho, B; Casemiro, L A; Watanabe, M G C; Pires-de-Souza, F C P

    2007-01-01

    This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield) and a photochromatic flowable composite resin (Tetric Flow Chroma) placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment--ten premolars were sealed with each material, isolated (except for the sealed surface) and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab). The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove's total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment--30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab). The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days). New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way ANOVA and Tukey's test P<0.05). Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  10. Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.

    PubMed

    Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan

    2008-01-01

    To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.

  11. Contact areas of the scaphoid and lunate with the distal radius in neutral and extension: correlation of falling strategies and distal radial anatomy.

    PubMed

    Chen, Y R; Wu, Y F; Tang, J B; Giddins, G

    2014-05-01

    The functional neutral of wrist movement is about 10° extension yet the distal radius has a volar tilt. This has not previously been explained. Assuming that the contact area between the carpus and the distal radius increased in wrist extension this would also help stabilize the carpus on the distal radius in positions where typically there is greater loading. To test this hypothesis we reconstructed three-dimensional structures of the carpal bones and distal radius using computed tomography scans of 13 normal wrists. The contact areas of the scaphoid with the distal radius were measured and were found progressively increased from flexion 20°, neutral, extension 20°, to extension 40°. The maximal increases in the contact area of the scaphoid and the distal radius was at full wrist extension. No significant changes in the contact areas of the lunate with the distal radius were found between the different positions. The contact characteristics provide greater stability to the carpus on the distal radius, and to help spread forces from impact to the wrist reducing the transmitted peak forces and thus the risk of distal radius and carpal injuries.

  12. Defining degree of aortic occlusion for partial-REBOA: A computed tomography study on large animals.

    PubMed

    Reva, Viktor A; Matsumura, Yosuke; Samokhvalov, Igor M; Pochtarnik, Alexander A; Zheleznyak, Igor S; Mikhailovskaya, Ekaterina M; Morrison, Jonathan J

    2018-04-20

    Partial resuscitative endovascular balloon occlusion of the aorta (P-REBOA) is a modified REBOA technique designed to help ameliorate ischemia-reperfusion injury. The balloon is partially deflated, allowing a proportion of aortic flow distal to the balloon. The aim of this study is to use an ovine model of haemorrhagic shock to correlate the degree of occlusion to several hemodynamic indices. Six sheep weighing 35-46 kg underwent a controlled venous haemorrhage inside a CT scanner until the systolic arterial pressure (AP) dropped to <90 mmHg. A balloon positioned in an aortic zone I was incrementally filled with 1 mL of saline, with serial measurement of the proximal (carotid artery) and distal (femoral artery) mean APs (MAP) and intra-balloon pressure (IBP), along with CT imaging, following each inflation, until full occlusion was achieved. A diameter of the aorta at zone I was 16.0 (15.7-17.2) mm, with a cross-sectional area of 212 (194-233) mm 2 . Median volume of saline injected into the balloon until total occlusion was 7.0 (6.3-8.5) mL. During gradual balloon inflation, proximal MAP increased and distal MAP decreased proportionate to the degree of occlusion, in a linear fashion (proximal: r 2  = 0.85, p < 0.001; distal: r 2  = 0.95, p < 0.001). The femoral/carotid (F/C) pressure gradient also demonstrated a linear trend (r 2  = 0.90, p < 0.001). The relationship between percentage occlusion and IBP was sigmoid. MAP values became significantly different at 40-49% occlusion and more (p < 0.01). Furthermore, a drop in the distal pulse pressure from 7.0 (5.5-16.5) to 2.0 (1.5-5.0) mmHg was observed at 80% occlusion. All animals had femoral pulse pressure <5 mmHg at 80% of occlusion and more, which also coincided with the observed loss of pulsatility of the femoral wave-form. Serial CT angiography at an ovine model of haemorrhagic shock demonstrates a correlation between the femoral MAP, F/C pressure gradient and degree of zone

  13. Occlusion handling framework for tracking in smart camera networks by per-target assistance task assignment

    NASA Astrophysics Data System (ADS)

    Bo, Nyan Bo; Deboeverie, Francis; Veelaert, Peter; Philips, Wilfried

    2017-09-01

    Occlusion is one of the most difficult challenges in the area of visual tracking. We propose an occlusion handling framework to improve the performance of local tracking in a smart camera view in a multicamera network. We formulate an extensible energy function to quantify the quality of a camera's observation of a particular target by taking into account both person-person and object-person occlusion. Using this energy function, a smart camera assesses the quality of observations over all targets being tracked. When it cannot adequately observe of a target, a smart camera estimates the quality of observation of the target from view points of other assisting cameras. If a camera with better observation of the target is found, the tracking task of the target is carried out with the assistance of that camera. In our framework, only positions of persons being tracked are exchanged between smart cameras. Thus, communication bandwidth requirement is very low. Performance evaluation of our method on challenging video sequences with frequent and severe occlusions shows that the accuracy of a baseline tracker is considerably improved. We also report the performance comparison to the state-of-the-art trackers in which our method outperforms.

  14. Design of retinal-projection-based near-eye display with contact lens.

    PubMed

    Wu, Yuhang; Chen, Chao Ping; Mi, Lantian; Zhang, Wenbo; Zhao, Jingxin; Lu, Yifan; Guo, Weiqian; Yu, Bing; Li, Yang; Maitlo, Nizamuddin

    2018-04-30

    We propose a design of a retinal-projection-based near-eye display for achieving ultra-large field of view, vision correction, and occlusion. Our solution is highlighted by a contact lens combo, a transparent organic light-emitting diode panel, and a twisted nematic liquid crystal panel. Its design rules are set forth in detail, followed by the results and discussion regarding the field of view, angular resolution, modulation transfer function, contrast ratio, distortion, and simulated imaging.

  15. Swept-Source Optical Coherence Tomography Angiography in West Nile Virus Chorioretinitis and Associated Occlusive Retinal Vasculitis.

    PubMed

    Khairallah, Moncef; Kahloun, Rim; Gargouri, Salma; Jelliti, Bechir; Sellami, Dorra; Ben Yahia, Salim; Feki, Jamel

    2017-08-01

    A 65-year-old man with diabetes and a history of fever of unknown origin 2 weeks earlier complained of sudden decreased vision in the left eye. The patient was diagnosed with bilateral West Nile virus (WNV) chorioretinitis associated with occlusive retinal vasculitis in the left eye. Swept-source optical coherence tomography angiography (SS-OCTA) of the left eye showed extensive, well-delineated, hypointense non-perfusion areas and perifoveal capillary arcade disruption in the superficial capillary plexus, as well as larger non-perfusion areas, capillary rarefaction, and diffuse capillary network attenuation and disorganization in the deep capillary plexus. OCTA may be a valuable tool for noninvasively assessing occlusive retinal vasculitis associated with WNV infection. It allows an accurate detection and precise delineation of areas of retinal capillary nonperfusion in both the superficial and deep capillary plexuses. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:672-675.]. Copyright 2017, SLACK Incorporated.

  16. Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis.

    PubMed

    Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio

    2017-11-25

    Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.

  17. Retinal vein occlusion

    MedlinePlus

    ... of one eye. Exams and Tests Tests to evaluate for vein occlusion include: Exam of the retina after dilating the pupil An eye test that uses a special dye and camera to look at blood flow in the retina and choroid. Intraocular pressure Pupil ...

  18. A non-contact time-domain scanning brain imaging system: first in-vivo results

    NASA Astrophysics Data System (ADS)

    Mazurenka, M.; Di Sieno, L.; Boso, G.; Contini, D.; Pifferi, A.; Dalla Mora, A.; Tosi, A.; Wabnitz, H.; Macdonald, R.

    2013-06-01

    We present results of first in-vivo tests of an optical non-contact scanning imaging system, intended to study oxidative metabolism related processes in biological tissue by means of time-resolved near-infrared spectroscopy. Our method is a novel realization of the short source-detector separation approach and based on a fast-gated single-photon avalanche diode to detect late photons only. The scanning system is built in quasi-confocal configuration and utilizes polarizationsensitive detection. It scans an area of 4×4 cm2, recording images with 32×32 pixels, thus creating a high density of source-detector pairs. To test the system we performed a range of in vivo measurements of hemodynamic changes in several types of biological tissues, i.e. skin (Valsalva maneuver), muscle (venous and arterial occlusions) and brain (motor and cognitive tasks). Task-related changes in hemoglobin concentrations were clearly detected in skin and muscle. The brain activation shows weaker, but yet detectable changes. These changes were localized in pixels near the motor cortex area (C3). However, it was found that even very short hair substantially impairs the measurement. Thus the applicability of the scanner is limited to hairless parts of body. The results of our first in-vivo tests prove the feasibility of non-contact scanning imaging as a first step towards development of a prototype for biological tissue imaging for various medical applications.

  19. Aqueous levels of erythropoietin in acute retinal vein occlusion with macular edema

    PubMed Central

    Shin, Hyun Jin; Kim, Hyung Chan; Moon, Jun Woong

    2014-01-01

    AIM To investigate the aqueous erythropoietin (EPO) levels and associated factors in patients with acute retinal vein occlusion (RVO). METHODS The aqueous EPO level was measured in patients with macular edema (ME) secondary to acute branched retinal vein occlusion (BRVO) or central retinal vein occlusion (CRVO). Aqueous fluid from cataract patients served as the control. We also evaluated whether aqueous level of EPO was associated with factors such as serum EPO level, non-perfusion area, central macular thickness (CMT), and arterio-venous (AV) transit time RESULTS Twenty-seven RVO patients (16 BRVO, 11 CRVO) and 9 control subjects were enrolled in the study. The aqueous EPO level (mU/mL) was higher in RVO (68.2±54.3) than that in the control subjects (12.9±5.9). More specifically, the aqueous EPO level was higher in CRVO (118.9±52.1) than that in BRVO (33.3±10.8). However, no differences were found in serum EPO levels among three groups. CMT in RVO patients had a positive correlation with the aqueous EPO level (r=0.66). Also, in terms of non-perfusion area, the aqueous EPO levels were more elevated in the ischemic subgroup than in the non-ischemic subgroup in both BRVO and CRVO. CONCLUSION Aqueous EPO levels are elevated in patients with macular edema secondary to recent onset RVO. Patients with CRVO have higher EPO levels than those with BRVO. The aqueous EPO level in RVO has a positive correlation with CMT and is associated with non-perfusion area. These results suggest that the aqueous EPO level could be associated with retinal ischemia and may be involved in the pathogenesis of macular edema secondary to RVO. PMID:24967199

  20. A system for simultaneous near-infrared reflectance and transillumination imaging of occlusal carious lesions

    NASA Astrophysics Data System (ADS)

    Simon, Jacob C.; Darling, Cynthia L.; Fried, Daniel

    2016-02-01

    Clinicians need technologies to improve the diagnosis of questionable occlusal carious lesions (QOC's) and determine if decay has penetrated to the underlying dentin. Assessing lesion depth from near-infrared (NIR) images holds great potential due to the high transparency of enamel and stain to NIR light at λ=1300-1700-nm, which allows direct visualization and quantified measurements of enamel demineralization. Unfortunately, NIR reflectance measurements alone are limited in utility for approximating occlusal lesion depth >200-μm due to light attenuation from the lesion body. Previous studies sought to combine NIR reflectance and transillumination measurements taken at λ=1300-nm in order to estimate QOC depth and severity. The objective of this study was to quantify the change in lesion contrast and size measured from multispectral NIR reflectance and transillumination images of natural occlusal carious lesions with increasing lesion depth and severity in order to determine the optimal multimodal wavelength combinations for estimating QOC depth. Extracted teeth with varying amounts of natural occlusal decay were measured using a multispectral-multimodal NIR imaging system at prominent wavelengths within the λ=1300-1700-nm spectral region. Image analysis software was used to calculate lesion contrast and area values between sound and carious enamel regions.

  1. An approximate JKR solution for a general contact, including rough contacts

    NASA Astrophysics Data System (ADS)

    Ciavarella, M.

    2018-05-01

    In the present note, we suggest a simple closed form approximate solution to the adhesive contact problem under the so-called JKR regime. The derivation is based on generalizing the original JKR energetic derivation assuming calculation of the strain energy in adhesiveless contact, and unloading at constant contact area. The underlying assumption is that the contact area distributions are the same as under adhesiveless conditions (for an appropriately increased normal load), so that in general the stress intensity factors will not be exactly equal at all contact edges. The solution is simply that the indentation is δ =δ1 -√{ 2 wA‧ /P″ } where w is surface energy, δ1 is the adhesiveless indentation, A‧ is the first derivative of contact area and P‧‧ the second derivative of the load with respect to δ1. The solution only requires macroscopic quantities, and not very elaborate local distributions, and is exact in many configurations like axisymmetric contacts, but also sinusoidal waves contact and correctly predicts some features of an ideal asperity model used as a test case and not as a real description of a rough contact problem. The solution permits therefore an estimate of the full solution for elastic rough solids with Gaussian multiple scales of roughness, which so far was lacking, using known adhesiveless simple results. The result turns out to depend only on rms amplitude and slopes of the surface, and as in the fractal limit, slopes would grow without limit, tends to the adhesiveless result - although in this limit the JKR model is inappropriate. The solution would also go to adhesiveless result for large rms amplitude of roughness hrms, irrespective of the small scale details, and in agreement with common sense, well known experiments and previous models by the author.

  2. Single-row versus double-row capsulolabral repair: a comparative evaluation of contact pressure and surface area in the capsulolabral complex-glenoid bone interface.

    PubMed

    Kim, Doo-Sup; Yoon, Yeo-Seung; Chung, Hoi-Jeong

    2011-07-01

    Despite the attention that has been paid to restoration of the capsulolabral complex anatomic insertion onto the glenoid, studies comparing the pressurized contact area and mean interface pressure at the anatomic insertion site between a single-row repair and a double-row labral repair have been uncommon. The purpose of our study was to compare the mean interface pressure and pressurized contact area at the anatomic insertion site of the capsulolabral complex between a single-row repair and a double-row repair technique. Controlled laboratory study. Thirty fresh-frozen cadaveric shoulders (mean age, 61 ± 8 years; range, 48-71 years) were used for this study. Two types of repair were performed on each specimen: (1) a single-row repair and (2) a double-row repair. Using pressure-sensitive films, we examined the interface contact area and contact pressure. The mean interface pressure was greater for the double-row repair technique (0.29 ± 0.04 MPa) when compared with the single-row repair technique (0.21 ± 0.03 MPa) (P = .003). The mean pressurized contact area was also significantly greater for the double-row repair technique (211.8 ± 18.6 mm(2), 78.4% footprint) compared with the single-row repair technique (106.4 ± 16.8 mm(2), 39.4% footprint) (P = .001). The double-row repair has significantly greater mean interface pressure and pressurized contact area at the insertion site of the capsulolabral complex than the single-row repair. The double-row repair may be advantageous compared with the single-row repair in restoring the native footprint area of the capsulolabral complex.

  3. Large area, low cost space solar cells with optional wraparound contacts

    NASA Technical Reports Server (NTRS)

    Michaels, D.; Mendoza, N.; Williams, R.

    1981-01-01

    Design parameters for two large area, low cost solar cells are presented, and electron irradiation testing, thermal alpha testing, and cell processing are discussed. The devices are a 2 ohm-cm base resistivity silicon cell with an evaporated aluminum reflector produced in a dielectric wraparound cell, and a 10 ohm-cm silicon cell with the BSF/BSR combination and a conventional contact system. Both cells are 5.9 x 5.9 cm and require 200 micron thick silicon material due to mission weight constraints. Normalized values for open circuit voltage, short circuit current, and maximum power calculations derived from electron radiation testing are given. In addition, thermal alpha testing values of absorptivity and emittance are included. A pilot cell processing run produced cells averaging 14.4% efficiencies at AMO 28 C. Manufacturing for such cells will be on a mechanized process line, and the area of coverslide application technology must be considered in order to achieve cost effective production.

  4. Role of occlusion in endodontic management: report of two cases.

    PubMed

    Yu, Christine Y

    2004-12-01

    The two clinical cases reported demonstrate that traumatic occlusion can play a role in the initiation and progression of pulp and periradicular inflammation. The symptom of persistent pain did not subside after the commencement of endodontic treatment. Traumatic occlusion was identified in both cases to be the main cause and hence occlusal adjustment was performed. This resulted in the gradual resolution of the symptoms. The findings suggest that occlusal trauma is often overlooked in the diagnosis and management of endodontic diseases.

  5. Influence of vision and dental occlusion on body posture in pilots.

    PubMed

    Baldini, Alberto; Nota, Alessandro; Cravino, Gaia; Cioffi, Clementina; Rinaldi, Antonio; Cozza, Paola

    2013-08-01

    Air force pilots have great postural control, movement coordination, motor learning, and motor transformation. They undergo abnormal stresses during flight that affect their organs and systems, with consequences such as barodontalgia, bruxism, TMJ dysfunctions, and cervical pain. The aim of this study was to evaluate the influence of dental occlusion and vision on their body posture. In collaboration with the "A. Mosso" Legal Medical Institute (Aeronautica Militare), two groups, consisting of 20 air force and 20 civilian pilots, were selected for the study using a protocol approved by the Italian Air Force. An oral examination and a force platform test were performed in order to evaluate the subjects' postural system efficiency. A MANOVA (Multivariate analysis of variance) analysis was performed by using the Wilkes' criterion, in order to statistically evaluate the influence of each factor. Both the sway area and velocity parameters are very strongly influenced by vision: the sway area increases by approximately 32% and the sway velocity increases by approximately 50% when the pilot closes his eyes. Only the sway area parameter was significantly influenced by the mandibular position: the mandibular position with eyes open changed the sway area by about 51% and with eyes closed by about 40%. No statistically significant differences were found between air force and civilian pilots. The results of this analysis show that occlusion and visual function could influence posture in air force and civilian pilots.

  6. [Comparison of 2 lacrimal punctal occlusion methods].

    PubMed

    Shalaby, O; Rivas, L; Rivas, A I; Oroza, M A; Murube, J

    2001-09-01

    To study and compare two methods for canalicular occlusion: Cautery and Punctal Patch. The study included fourty patients divided in two groups of 20 patients. The end point was 4 occluded puncti. The first group underwent deep cauterization resulting in occlusion of the full vertical aspect of the canaliculus. The second group underwent punctal patch technique for canalicular occlusion. Differential parameters were the following: time of intervention, ease of use, risks and precision. In the post operatory, discomfort, subjective and objective improvement in ocular surface as well as long term result of each technique was analysed. Time of intervention was longer for punctal patch compared to cautery. Both methods exhibited similar ease of use and improvement in ocular surface. Precision was high in punctal patch technique showing complete and final occlusion and no punctum needed reopening, while cautery technique presented 20% rate of reopening intervention. Postoperatory discomfort and irritation were remarkably evident with punctal technique, while minimal in cautery technique. Survival analysis after one year follow up, showed a higher rate of advantages for punctal patch technique over cautery technique.

  7. The Risk of Depressive Disorder Among Contacts of Tuberculosis Patients in a TB-endemic Area

    PubMed Central

    Pan, Sheng-Wei; Yen, Yung-Feng; Feng, Jia-Yih; Su, Vincent Yi-Fong; Kou, Yu Ru; Su, Wei-Juin

    2015-01-01

    Abstract Tuberculosis (TB) disease may be transmitted to close contacts of index cases, causing physical illness. No studies have investigated the risk of developing depressive disorder among TB contacts in a TB-endemic area. Adult participants with a new diagnosis of TB contact (ICD-9-CM codes V01.1 plus chest radiographic order) since January 1, 2008, were identified from the National Health Insurance Research Database in Taiwan. A control cohort matched for age (±5 y), sex, enrolled years, and income level was selected. These 2 cohorts were followed until December 31, 2012, and observed for the development of depressive disorder. The Kaplan-Meier method and the log-rank test were used to examine the difference in cumulative incidences of depressive disorder between groups. Cox proportional-hazard models were used to calculate adjusted hazard ratios (aHRs) for depressive disorder. The TB contact cohort consisted of 9046 patients and matched controls of 36,184 ones. The mean age of TB contacts was 44.7 years, and 56.0% of them were women. During a mean follow-up period of 2.5 years, 127 (1.40%) TB contacts and 521 (1.44%) matched controls developed depressive disorder. TB exposure was found to be an independent risk factor of depressive disorder in women (aHR 1.34, 95% confidence interval [CI] 1.07–1.68), but not in men (aHR 0.71, 95% CI 0.48–1.06) after adjusting for age, comorbidities, and income levels. The risk of depression was significantly higher for female TB contacts than for matched controls in the first and second years (aHR 1.49, 95% CI 1.03–2.14; and aHR 1.53, 95% CI 1.05–2.23, respectively), but not thereafter. Of note, 67 (0.74%) TB contacts and 88 (0.24%) matched controls developed active TB, but none of them had subsequent depressive disorder during follow-up periods. Female TB contacts had an increased risk of depression within the first 2 years after exposure. Clinicians should consider conducting depression evaluations in addition to

  8. Collateral Circulation in Chronic Total Occlusions - an interventional perspective.

    PubMed

    Choo, Gim-Hooi

    2015-09-09

    Human coronary collaterals are inter-coronary communications that are believed to be present from birth. In the presence of chronic total occlusions, recruitment of flow via these collateral anastomoses to the arterial segment distal to occlusion provide an alternative source of blood flow to the myocardial segment at risk. This mitigates the ischemic injury. Clinical outcome of coronary occlusion ie. severity of myocardial infarction/ischemia, impairment of cardiac function and possibly survival depends not only on the acuity of the occlusion, extent of jeopardized myocardium, duration of ischemia but also to the adequacy of collateral circulation. Adequacy of collateral circulation can be assessed by various methods. These coronary collateral channels have been used successfully as a retrograde access route for percutaneous recanalization of chronic total occlusions. Factors that promote angiogenesis and further collateral remodeling ie. arteriogenesis have been identified. Promotion of collateral growth as a therapeutic target in patients with no suitable revascularization option is an exciting proposal.

  9. Acute pancreatitis during sickle cell vaso-occlusive painful crisis.

    PubMed

    Ahmed, Shahid; Siddiqui, Anita K; Siddiqui, Rina K; Kimpo, Miriam; Russo, Linda; Mattana, Joseph

    2003-07-01

    Sickle cell disease is characterized by chronic hemolytic anemia and vaso-occlusive painful crisis. The vascular occlusion in sickle cell disease is a complex process and accounts for the majority of the clinical manifestations of the disease. Abdominal pain is an important component of vaso-occlusive painful crisis and may mimic diseases such as acute appendicitis and cholecystitis. Acute pancreatitis is rarely included as a cause of abdominal pain in patients with sickle cell disease. When it occurs it may result form biliary obstruction, but in other instances it might be a consequence of microvessel occlusion causing ischemia. In this series we describe four cases of acute pancreatitis in patients with sickle cell disease apparently due to microvascular occlusion and ischemic injury to the pancreas. All patients responded to conservative management. Acute pancreatitis should be considered in the differential diagnosis of abdominal pain in patients with sickle cell disease. Copyright 2003 Wiley-Liss, Inc.

  10. Occlusion of Arteriovenous Fistulas of In-Situ Saphenous Vein Bypass Grafts Using the Amplatzer Vascular Plug 4: Initial Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libicher, Martin, E-mail: martin.libicher@uk-koeln.de; Reichert, V.; Schwabe, H.

    2011-06-15

    We examined the safety and efficacy of vessel occlusion of the Amplatzer Vascular Plug 4 (AVP-4) in patients with arteriovenous fistulas after in-situ saphenous vein bypass grafts. We treated 18 fistulas of seven patients (four women, mean {+-} standard deviation age 76 {+-} 7 years, range 63-88 years). All fistulas were detected within 14 days after surgery. Initial diagnosis and follow-up was established by sonography. We measured the diameter of the feeding vessel and the time of vessel occlusion after plug deployment. Additionally, we recorded procedure time and the dose area product. Additional interventional procedures were necessary in three patients.more » We successfully used 19 AVP-4 for occlusion of all fistulas without thromboembolic complications. There was no need for recapturing the device, and we did not observe dislocation. Mean occlusion time was 9.6 min (range 5-22 min). Mean diameter of the feeding vessels was 3.5 mm (range 2.6-5.1 mm). Plug sizes ranged from 4-8 mm (mean 5.5 mm) resulting in an oversizing of 33-88%. Mean procedure time for patients with and without additional intervention was 91 {+-} 38 min and 35 {+-} 18 min, respectively. Mean dose area product was 11,790 cGy/cm{sup 2} (range 1,850-23,500 cGy/cm{sup 2}). Permanent occlusion of the fistulas was confirmed by ultrasound after a mean follow-up of 4 months (1-6 months). Occlusion of arteriovenous fistulas with an AVP-4 seems to be effective and safe in patients with in-situ saphenous vein bypass grafts. The AVP-4 is well suited for this purpose because of the appropriate diameter of the feeding vessels.« less

  11. Computational evaluation of aortic occlusion and the proposal of a novel, improved occluder: Constrained endo-aortic balloon occlusion.

    PubMed

    de Vaal, M H; Gee, M W; Stock, U A; Wall, W A

    2016-12-01

    Because aortic occlusion is arguably one of the most dangerous aortic manipulation maneuvers during cardiac surgery in terms of perioperative ischemic neurological injury, the purpose of this investigation is to assess the structural mechanical impact resulting from the use of existing and newly proposed occluders. Existing (clinically used) occluders considered include different cross-clamps (CCs) and endo-aortic balloon occlusion (EABO). A novel occluder is also introduced, namely, constrained EABO (CEABO), which consists of applying a constrainer externally around the aorta when performing EABO. Computational solid mechanics are employed to investigate each occluder according to a comprehensive list of functional requirements. The potential of a state of occlusion is also considered for the first time. Three different constrainer designs are evaluated for CEABO. Although the CCs were responsible for the highest strains, largest deformation, and most inefficient increase of the occlusion potential, it remains the most stable, simplest, and cheapest occluder. The different CC hinge geometries resulted in poorer performance of CC used for minimally invasive procedures than conventional ones. CEABO with a profiled constrainer successfully addresses the EABO shortcomings of safety, stability, and positioning accuracy, while maintaining its complexities of operation (disadvantage) and yielding additional functionalities (advantage). Moreover, CEABO is able to achieve the previously unattainable potential to provide a clinically determinable state of occlusion. CEABO offers an attractive alternative to the shortcomings of existing occluders, with its design rooted in achieving the highest patient safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Traumatic occlusion of the anterior cerebral artery--case report.

    PubMed

    Ishibashi, A; Kubota, Y; Yokokura, Y; Soejima, Y; Hiratsuka, T

    1995-12-01

    A 71-year-old female presented with posttraumatic occlusion of the anterior cerebral artery (ACA) after a road accident in which she was hit in the mid-frontal region. Initial computed tomography (CT) demonstrated frontal skull fractures and pneumocephalus. High density areas were also identified in the right basal cisterns, suggesting traumatic subarachnoid hemorrhage. She was alert on admission, but with attendant shock due to crush wounds. Her condition rapidly deteriorated and an emergency amputation of her left leg was performed. After aggressive treatment with transfusion and infusion, her systolic pressure increased to 120 mmHg. Her consciousness remained disturbed. Serial CT disclosed hemorrhagic infarction in the entire medial side of the right frontal lobe. Magnetic resonance angiography demonstrated decreased flow voids in the bilateral A1 segments and right ACA, and a basilar artery aneurysm, which was unruptured clinically. Three weeks after the injury, she regained consciousness. Six months later, she had motor aphasia and left upper extremity weakness. The clinicopathological mechanism causing the traumatic occlusion of the ACA in the present case was probably dissecting aneurysm.

  13. Time-to-Contact Judgments of an Approaching Object that Is Partially Concealed by an Occluder

    ERIC Educational Resources Information Center

    DeLucia, Patricia R.

    2004-01-01

    Prior studies of time-to-contact (TTC) focused on judgments of unoccluded approaching objects. P. R. DeLucia, M. K. Kaiser, J. M. Bush, L. E. Meyer, and B. T. Sweet (2003) showed that partial occlusion decreases an object's optical size and expansion rate and that the value of tau derived from the reduced optical size (relative rate of accretion;…

  14. Venous sinus occlusive disease: MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuh, W.T.C.; Simonson, T.M.; Tali, E.T.

    1994-02-01

    To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attention to mass effect, hemorrhage, and T2-weighted image abnormalities as well as to abnormal parenchymal, venous, or arterial enhancement after intravenous gadopentetate dimeglumine administration. Follow-up studies when available were evaluated for atrophy, infraction, chronic mass effect, and hemorrhage. Mass effect was present in 25 of 26more » patients. Eleven of the 26 had mass effect without abnormal signal on T2-weighted images. Fifteen patients had abnormal signal on T2-weighted images, but this was much less extensive than the degree of brain swelling in all cases. No patient showed abnormal parenchymal or arterial enhancement. Abnormal venous enhancement was seen in 10 of 13 patients who had contrast-enhanced studies. Intraparenchymal hemorrhage was seen in nine patients with high signal on T2-weighted images predominantly peripheral to the hematoma in eight. Three overall MR patterns were observed in acute sinus thrombosis: (1) mass effect without associated abnormal signal on T2-weighted images, (2) mass effect with associated abnormal signal on T2-weighted images and/or ventricular dilatation that may be reversible, and (3) intraparenchymal hematoma with surrounding edema. MR findings of venus sinus occlusive disease are different from those of arterial ischemia and may reflect different underlying pathophysiology. In venous sinus occlusive disease, the breakdown of the blood-brain barrier (vasogenic edema and abnormal parenchymal enhancement) does not always occur, and brain swelling can persist up to 2 years with or without abnormal signal on T2-weighted images. 34 refs., 5 figs.« less

  15. Compliance with the prescribed occlusion treatment for amblyopia.

    PubMed

    Vagge, Aldo; Nelson, Leonard B

    2017-09-01

    The present review article is an update on the current evidence about compliance to the prescribed occlusion treatment for amblyopia. In particular, the authors focus on the predictors and causes of noncompliance and possible interventions to increase it. Compliance with prescribed occlusion treatment is often challenging. Reported rates of compliance range widely from 49% to 87%. Objective monitoring of occlusion has opened up new research opportunities and allow the design of effective therapeutic regimens. Also, predictors and causes of noncompliance have been investigated and their knowledge may help the clinician to improved compliance with prescribed occlusion treatment for amblyopia. Although many of the studies assessing the effectiveness of interventions to increase compliance to patching treatment for amblyopia have many limitations, evidences support that use of educational supports, parents, and patient understanding on the importance of patching and written information should be considered to increase compliance with patching.

  16. Automated vision occlusion-timing instrument for perception-action research.

    PubMed

    Brenton, John; Müller, Sean; Rhodes, Robbie; Finch, Brad

    2018-02-01

    Vision occlusion spectacles are a highly valuable instrument for visual-perception-action research in a variety of disciplines. In sports, occlusion spectacles have enabled invaluable knowledge to be obtained about the superior capability of experts to use visual information to guide actions within in-situ settings. Triggering the spectacles to occlude a performer's vision at a precise time in an opponent's action or object flight has been problematic, due to experimenter error in using a manual buttonpress approach. This article describes a new laser curtain wireless trigger for vision occlusion spectacles that is portable and fast in terms of its transmission time. The laser curtain can be positioned in a variety of orientations to accept a motion trigger, such as a cricket bowler's arm that distorts the lasers, which then activates a wireless signal for the occlusion spectacles to change from transparent to opaque, which occurs in only 8 ms. Results are reported from calculations done in an electronics laboratory, as well as from tests in a performance laboratory with a cricket bowler and a baseball pitcher, which verified this short time delay before vision occlusion. In addition, our results show that occlusion consistently occurred when it was intended-that is, near ball release and during mid-ball-flight. Only 8% of the collected data trials were unusable. The laser curtain improves upon the limitations of existing vision occlusion spectacle triggers, indicating that it is a valuable instrument for perception-action research in a variety of disciplines.

  17. Virtual occlusal definition for orthognathic surgery.

    PubMed

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. On the relevance of "ideal" occlusion concepts for incisor inclination target definition.

    PubMed

    Knösel, Michael; Jung, Klaus

    2011-11-01

    The concept of "ideal" occlusion in harmony with craniofacial structures is often proposed as an ultimate goal of orthodontic treatment. The aim of this study was to assess the impact of slight variations in posterior occlusion and the history of straight-wire orthodontic treatment on the predictability of incisor inclination and third-order angles. Axial incisor inclinations, third-order angles, and craniofacial relationships were assessed on lateral headfilms and corresponding dental casts of 75 healthy white subjects, 16 to 26 years old, selected by the general inclusion criterion of a good interincisal relationship. Four groups were formed: group A (n = 17), Angle Class I occlusion subjects with no orthodontic treatment; group B (n = 20), Angle Class I occlusion subjects treated with standardized straight-wire orthodontics; group C (n = 20), up to a half-cusp distal occlusion after straight-wire treatment; and group D (n = 18), up to a half-cusp distal occlusion and no orthodontic treatment. Regression analysis was used to insert predictor angles into selected regression equations of the subjects with "ideal" occlusion, and the absolute differences between predicted and observed response angles were determined. Small differences in incisor inclination were found between subjects with "ideal" occlusion and those who slightly deviated from "ideal" with a mild occlusion of the Angle Class II category. Posterior occlusion was not relevant to the validity of the vast majority of predictor-response pairs. Straight-wire treatment produced incisor inclination that was slightly protruded compared with subjects who had good natural occlusion. The "ideal" posterior occlusion concepts as a general orthodontic treatment goal should be reconsidered. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    PubMed

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  20. 24 and 48 h allergen exposure in patch testing. Comparative study with 11 common contact allergens and NiCl2.

    PubMed

    Kalimo, K; Lammintausta, K

    1984-01-01

    Patch test reactions to 11 common contact allergens were studied after 24 h and 48 h occlusion with Finn Chambers in 390 patients. Concordant allergic results were found in 96 cases (74%). In 22 patients (17%), the reaction was positive only after 48 h and in 11 cases (8.5%) only after 24 h exposure. Most of the discordant reactions were to nickel, cobalt, neomycin, formaldehyde and perfume mix. Irritant reactions were found in 55 cases, the majority occurring after 48 h occlusion. Nickel chloride tested in parallel with 48 h exposure lead to more positive allergic and toxic reactions than nickel sulphate.

  1. Mechanism of vaso-occlusion in sickle cell anemia

    NASA Astrophysics Data System (ADS)

    Lei, Huan; Karniadakis, George

    2012-11-01

    Vaso-occlusion crisis is one of the key hallmark of sickle cell anemia. While early studies suggested that the crisis is caused by blockage of a single elongated cell, recent experimental investigations indicate that vaso-occlusion is a complex process triggered by adhesive interactions among different cell groups in multiple stages. Based on dissipative particle dynamics, a multi-scale model for the sickle red blood cells (SS-RBCs), accounting for diversity in both shapes and cell rigidities, is developed to investigate the mechanism of vaso-occlusion crisis. Using this model, the adhesive dynamics of single SS-RBC was investigated in arterioles. Simulation results indicate that the different cell groups (deformable SS2 RBCs, rigid SS4 RBCs, leukocytes, etc.) exhibit heterogeneous adhesive behavior due to the different cell morphologies and membrane rigidities. We further simulate the tube flow of SS-RBC suspensions with different cell fractions. The more adhesive SS2 cells interact with the vascular endothelium and further trap rigid SS4 cells, resulting in vaso-occlusion in vessels less than 15 μm . Under inflammation, adherent leukocytes may also trap SS4 cells, resulting in vaso-occlusion in even larger vessels. This work was supported by the NSF grant CBET-0852948 and the NIH grant R01HL094270.

  2. Occlusal tooth wear in Chinese adults with shortened dental arches.

    PubMed

    Zhang, Q; Witter, D J; Bronkhorst, E M; Bartlett, D W; Creugers, N H J

    2014-02-01

    To assess associations between occlusal tooth wear and shortened dental arches (SDA) in Chinese 40 years and older subjects. From a sample of 1462 urban and rural adults, those presenting with SDA (n = 150) were compared with a control group of 65 randomly selected subjects with complete dentitions (CDA). Occlusal wear was assessed using a modified Smith and Knight index - the occlusal tooth wear index (OWTI) - and analysed using multivariate (logistic) regression. There was no significant effect from SDA on severe occlusal wear (OTWI score 3 or 4: OR = 2.016; 95% CI = 0.960-4.231; P = 0.064). Higher age was associated with severe occlusal wear (P values ≤0.007) and with higher mean OTWI scores; urban had less often severe occlusal wear than rural residents (OR = 0.519; P = 0.008). Higher mean OTWI scores were associated with rural residents, except for anterior teeth. Females had lower mean OTWI score for anterior teeth (effect = -0.153; P = 0.030). Premolars in SDA had higher mean OTWI scores compared with those in CDA (effect = +0.213; P = 0.006). In SDA, more posterior occluding pairs (POPs) were associated with lower mean OTWI sores for anterior teeth (effect: -0.158; P = 0.008) and higher scores for molars (effect: +0.249, P = 0.003). Subjects with SDA or CDA presented comparable occlusal wear, but premolars in SDA tend to have higher probability for having occlusal wear. Fewer numbers of POPs were associated with more wear in anterior teeth. © 2013 John Wiley & Sons Ltd.

  3. Near-IR Image-Guided Laser Ablation of Demineralization on Tooth Occlusal Surfaces

    PubMed Central

    Tom, Henry; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel

    2016-01-01

    Introduction Studies have shown that reflectance images at near-IR wavelengths coincident with higher water absorption are well-suited for image-guided laser ablation of carious lesions since the contrast between sound and demineralized enamel is extremely high and interference from stains is minimized. The objective of this study was to demonstrate that near-IR reflectance images taken at a wavelength range of 1,500–1,700 nm can be used to guide a 9.3 μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. Methods The occlusal surfaces of ten sound human molars were used in this in vitro study. Shallow simulated caries lesions with random patterns and varying depth and position were produced on tooth occlusal surfaces. Sequential near-IR reflectance images at 1,500–1,700 nm were used to guide the laser for the selective removal of the demineralized enamel. Digital microscopy and polarization sensitive optical coherence tomography (PS-OCT) were used to assess selectivity. Results Images taken before and after lesion removal suggest that the demineralized areas were removed with high selectivity. Although the estimated volume of tissue ablated was typically higher than the initial lesion volume measured with PS-OCT, the volume of enamel removed by the laser correlated well with the initial lesion volume. Conclusion Sequential near-IR reflectance images at 1,500–1,700 nm can be used to guide a 9.3 μm CO2 laser for the selective ablation of early demineralization on tooth occlusal surfaces. PMID:26763111

  4. Full area covered 3D profile measurement of special-shaped optics based on a new prototype non-contact profiler

    NASA Astrophysics Data System (ADS)

    Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu

    2017-06-01

    A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.

  5. Full area covered 3D profile measurement of special-shaped optics based on a new prototype non-contact profiler.

    PubMed

    Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu

    2017-06-01

    A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.

  6. Future prospects for contact factors as therapeutic targets

    PubMed Central

    Gailani, David

    2015-01-01

    Anticoagulants currently used in clinical practice to treat or prevent thromboembolic disease are effective, but place patients at increased risk for serious bleeding because they interfere with plasma enzymes (thrombin and factor Xa) that are essential for hemostasis. In the past 10 years, work with genetically altered mice and studies in baboons and rabbits have demonstrated that the plasma contact proteases factor XI, factor XII, and prekallikrein contribute to the formation of occlusive thrombi despite having limited roles in hemostasis. In the case of factor XI, epidemiologic data from human populations indicate that elevated levels of this protein increase risk for stroke and venous thromboembolism and may also influence risk for myocardial infarction. These findings suggest that inhibiting contact activation may produce an antithrombotic effect without significantly compromising hemostasis. This chapter reviews strategies that are being developed for therapeutic targeting of factor XI and factor XII and their performances in preclinical and early human trials. PMID:25696834

  7. Pulmonary veno-occlusive disease and pulmonary capillary hemangiomatosis.

    PubMed

    Ortiz-Bautista, Carlos; Hernández-González, Ignacio; Escribano-Subías, Pilar

    2017-03-22

    Pulmonary veno-occlusive disease is a rare cause of pulmonary hypertension which is part, together with pulmonary capillary hemangiomatosis, of the special designation (subgroup 1') within pulmonary hypertension group 1 in the latest classification of the pulmonary hypertension World Symposium. Recent discovery that gene mutations in eukaryotic translation initiation factor 2 alpha kinase 4 (EIF2AK4) are responsible for inherited forms of pulmonary veno-occlusive disease has changed the role of genetic testing, acquiring relevant importance in the diagnosis of these patients. Despite the advances in genetic, cellular and molecular basis knowledge in the last decade, pulmonary veno-occlusive disease remains as a rare aetiology of pulmonary hypertension without any effective medical treatment approved and poor outcomes. This document aims to review the advances occurred in the understanding of pulmonary veno-occlusive disease in the last years. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  8. A change in humidification system can eliminate endotracheal tube occlusion.

    PubMed

    Doyle, Alex; Joshi, Manasi; Frank, Peter; Craven, Thomas; Moondi, Parvez; Young, Peter

    2011-12-01

    Inadequate airway humidification can result in endotracheal tube occlusion. There is evidence that heat and moisture exchangers (HMEs) are more prone to endotracheal tube occlusion than heated humidifiers (HHs) that contain a heated wire circuit. We aimed to compare the incidence of endotracheal tube occlusion while introducing a new dual-heated wire circuit HH in place of an established hydrophobic HME. This was a prospective observational study. All patients who required intubation were included in our analysis. Univariate statistical analysis was performed using a Fisher exact test. P < .05 was considered statistically significant. There were 158 patients in the HME group and 88 patients in the HH group. The incidence of endotracheal tube occlusion was 5.7% in the HME group and 0% in the HH group. Statistical analysis revealed a significant difference between the 2 groups (P = .02). In light of this finding, we changed our practice to provide humidification exclusively by HH. In the subsequent 18-month period, there were no further episodes of endotracheal tube occlusion. Our study demonstrates that there is a significant increase in the incidence of endotracheal tube occlusion when using a hydrophobic HME compared with an HH and that using a dual-heated wire circuit HH can eliminate endotracheal tube occlusion. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Does partial occlusion promote normal binocular function?

    PubMed

    Li, Jingrong; Thompson, Benjamin; Ding, Zhaofeng; Chan, Lily Y L; Chen, Xiang; Yu, Minbin; Deng, Daming; Hess, Robert F

    2012-10-03

    There is growing evidence that abnormal binocular interactions play a key role in the amblyopia syndrome and represent a viable target for treatment interventions. In this context the use of partial occlusion using optical devices such as Bangerter filters as an alternative to complete occlusion is of particular interest. The aims of this study were to understand why Bangerter filters do not result in improved binocular outcomes compared to complete occlusion, and to compare the effects of Bangerter filters, optical blur and neutral density (ND) filters on normal binocular function. The effects of four strengths of Bangerter filters (0.8, 0.6, 0.4, 0.2) on letter and vernier acuity, contrast sensitivity, stereoacuity, and interocular suppression were measured in 21 observers with normal vision. In a subset of 14 observers, the partial occlusion effects of Bangerter filters, ND filters and plus lenses on stereopsis and interocular suppression were compared. Bangerter filters did not have graded effect on vision and induced significant disruption to binocular function. This disruption was greater than that of monocular defocus but weaker than that of ND filters. The effect of the Bangerter filters on stereopsis was more pronounced than their effect on monocular acuity, and the induced monocular acuity deficits did not predict the induced deficits in stereopsis. Bangerter filters appear to be particularly disruptive to binocular function. Other interventions, such as optical defocus and those employing computer generated dichoptic stimulus presentation, may be more appropriate than partial occlusion for targeting binocular function during amblyopia treatment.

  10. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    PubMed Central

    Kothari, Mihir

    2014-01-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa. PMID:23571255

  11. Occlusion-amblyopia following high dose oral levodopa combined with part time patching.

    PubMed

    Kothari, Mihir

    2014-12-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  12. Ocular Complications Following Autologous Fat Injections into Facial Area: Case Report of a Recovery from Visual Loss After Ophthalmic Artery Occlusion and a Review of the Literature.

    PubMed

    Szantyr, Aleksandra; Orski, Michał; Marchewka, Ida; Szuta, Mariusz; Orska, Małgorzata; Zapała, Jan

    2017-06-01

    With the increase in popularity of the use of cosmetic fillers in plastic and esthetic surgery, the possibility of severe ocular complications should not be neglected. Of the fillers used, autologous fat is the most common to cause permanent visual deterioration, one of the most severe complications associated with the use of cosmetic fillers. Here we present the first report of a complete recovery of visual acuity from an instance of visual loss with no light perception caused by ophthalmic artery occlusion of the right eye following autologous fat injection in the facial area. Immediate ophthalmological intervention and comprehensive therapy with prostaglandins and vinpocetine made it possible to restore retinal perfusion and achieve complete recovery of visual acuity. Awareness of the iatrogenic artery occlusions associated with facial fillers and the need for immediate treatment should be popularized among injectors to prevent devastating consequences, such as permanent vision loss. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  13. Combined Central Retinal Vein and Branch Retinal Artery Occlusion Post Intense Physical Activity.

    PubMed

    Coca, Mircea; Tecle, Nahom; Amde, Wendewessen; Mehta, Ankur

    2017-08-23

    We report a case of combined central retinal vein occlusion and branch retinal artery occlusion. A previously healthy 47-year-old male presented with decreased vision in the right eye after completing a half marathon. A fundus exam and retinal imaging revealed a combined central retinal vein and branch retinal artery occlusion. In the present report, we review the literature and discuss the possible mechanisms behind combined retinal vessel occlusions. To our knowledge, this is the first reported case of combined central retinal vein occlusion and branch retinal artery occlusion following intense exercise.

  14. Combined Central Retinal Vein and Branch Retinal Artery Occlusion Post Intense Physical Activity

    PubMed Central

    Tecle, Nahom; Amde, Wendewessen; Mehta, Ankur

    2017-01-01

    We report a case of combined central retinal vein occlusion and branch retinal artery occlusion. A previously healthy 47-year-old male presented with decreased vision in the right eye after completing a half marathon. A fundus exam and retinal imaging revealed a combined central retinal vein and branch retinal artery occlusion. In the present report, we review the literature and discuss the possible mechanisms behind combined retinal vessel occlusions. To our knowledge, this is the first reported case of combined central retinal vein occlusion and branch retinal artery occlusion following intense exercise. PMID:29067224

  15. Development and Validation of a Novel Scoring System for Predicting Technical Success of Chronic Total Occlusion Percutaneous Coronary Interventions: The PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) Score.

    PubMed

    Christopoulos, Georgios; Kandzari, David E; Yeh, Robert W; Jaffer, Farouc A; Karmpaliotis, Dimitri; Wyman, Michael R; Alaswad, Khaldoon; Lombardi, William; Grantham, J Aaron; Moses, Jeffrey; Christakopoulos, Georgios; Tarar, Muhammad Nauman J; Rangan, Bavana V; Lembo, Nicholas; Garcia, Santiago; Cipher, Daisha; Thompson, Craig A; Banerjee, Subhash; Brilakis, Emmanouil S

    2016-01-11

    This study sought to develop a novel parsimonious score for predicting technical success of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) performed using the hybrid approach. Predicting technical success of CTO PCI can facilitate clinical decision making and procedural planning. We analyzed clinical and angiographic parameters from 781 CTO PCIs included in PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) using a derivation and validation cohort (2:1 sampling ratio). Variables with strong association with technical success in multivariable analysis were assigned 1 point, and a 4-point score was developed from summing all points. The PROGRESS CTO score was subsequently compared with the J-CTO (Multicenter Chronic Total Occlusion Registry in Japan) score in the validation cohort. Technical success was 92.9%. On multivariable analysis, factors associated with technical success included proximal cap ambiguity (beta coefficient [b] = 0.88), moderate/severe tortuosity (b = 1.18), circumflex artery CTO (b = 0.99), and absence of "interventional" collaterals (b = 0.88). The resulting score demonstrated good calibration and discriminatory capacity in the derivation (Hosmer-Lemeshow chi-square = 2.633; p = 0.268, and receiver-operator characteristic [ROC] area = 0.778) and validation (Hosmer-Lemeshow chi-square = 5.333; p = 0.070, and ROC area = 0.720) subset. In the validation cohort, the PROGRESS CTO and J-CTO scores performed similarly in predicting technical success (ROC area 0.720 vs. 0.746, area under the curve difference = 0.026, 95% confidence interval = -0.093 to 0.144). The PROGRESS CTO score is a novel useful tool for estimating technical success in CTO PCI performed using the hybrid approach. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair.

    PubMed

    Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min

    2016-01-01

    To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Distance of the contact glide in the closing masticatory stroke during mastication of three types of food.

    PubMed

    Rilo, B; Fernández-Formoso, N; Mora, M J; Cadarso-Suárez, C; Santana, U

    2009-08-01

    This study was designed to characterize the distance of the contact glide in the closing masticatory stroke in healthy adult subjects, during chewing of three types of food (crustless bread, chewing gum and peanuts). Mandibular movements (masticatory movements and laterality movements with dental contact) were registered using a gnathograph (MK-6I Diagnostic System) on the right and left side during unilateral chewing of the three food types. Length of dental contact was measured in masticatory cycle, which is defined as where the terminal part of the chewing cycles could be superimposed on the pathways taken by the mandible during lateral excursions with occlusal contacts. The length of dental contact during mastication of chewing gum is 1.46 +/- 1 mm, during chewing of soft bread is 1.38 +/- 0.7 mm and during chewing of peanuts is 1.45 +/- 0.9 mm. There is no significant difference in the lengths of dental contact during mastication of three types of foods that enable direct tooth gliding.

  18. Improving prediction of recanalization in acute large-vessel occlusive stroke.

    PubMed

    Vanacker, P; Lambrou, D; Eskandari, A; Maeder, P; Meuli, R; Ntaios, G; Michel, P

    2014-06-01

    Recanalization in acute ischemic stroke with large-vessel occlusion is a potent indicator of good clinical outcome. To identify easily available clinical and radiologic variables predicting recanalization at various occlusion sites. All consecutive, acute stroke patients from the Acute STroke Registry and Analysis of Lausanne (2003-2011) who had a large-vessel occlusion on computed tomographic angiography (CTA) (< 12 h) were included. Recanalization status was assessed at 24 h (range: 12-48 h) with CTA, magnetic resonance angiography, or ultrasonography. Complete and partial recanalization (corresponding to the modified Treatment in Cerebral Ischemia scale 2-3) were grouped together. Patients were categorized according to occlusion site and treatment modality. Among 439 patients, 51% (224) showed complete or partial recanalization. In multivariate analysis, recanalization of any occlusion site was most strongly associated with endovascular treatment, including bridging therapy (odds ratio [OR] 7.1, 95% confidence interval [CI] 2.2-23.2), and less so with intravenous thrombolysis (OR 1.6, 95% CI 1.0-2.6) and recanalization treatments performed beyond guidelines (OR 2.6, 95% CI 1.2-5.7). Clot location (large vs. intermediate) and tandem pathology (the combination of intracranial occlusion and symptomatic extracranial stenosis) were other variables discriminating between recanalizers and non-recanalizers. For patients with intracranial occlusions, the variables significantly associated with recanalization after 24 h were: baseline National Institutes of Health Stroke Scale (NIHSS) (OR 1.04, 95% CI 1.02-1.1), Alberta Stroke Program Early CT Score (ASPECTS) on initial computed tomography (OR 1.2, 95% CI 1.1-1.3), and an altered level of consciousness (OR 0.2, 95% CI 0.1-0.5). Acute endovascular treatment is the single most important factor promoting recanalization in acute ischemic stroke. The presence of extracranial vessel stenosis or occlusion decreases

  19. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  20. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  1. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  2. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  3. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  4. Measurement of occlusion of the spinal canal and intervertebral foramen by intervertebral disc bulge

    PubMed Central

    Cuchanski, Mathieu; Cook, Daniel; Whiting, Donald M.; Cheng, Boyle C.

    2011-01-01

    Background Disc protrusion has been proposed to be a possible cause of both pain and stenosis in the lower spine. No previous study has described the amount of disc occlusion of the spinal canal and intervertebral foramen that occurs under different loading conditions. The objective of this study was to quantitatively assess the percent occlusion of the spinal canal and intervertebral foramen by disc bulge under different loading conditions. Methods Spinal canal depth and foraminal width were measured on computed tomography–scanned images of 7 human lumbar spine specimens. In vitro disc bulge measurements were completed by use of a previously described method in which single functional spinal units were subjected to 3 separate load protocols in a spine test machine and disc bulge was recorded with an optoelectric motion system that tracked active light-emitting diodes placed on the posterior and posterolateral aspects of the intervertebral disc. Occlusion was defined as percentage of encroachment into area of interest by maximum measured disc bulge at corresponding point of interest (the spinal canal is at the posterior point; the intervertebral foramen is at the posterolateral point). Results The mean spinal canal depth and mean foraminal width were 19 4 ± mm and 5 ± 2 mm, respectively. Mean spinal canal occlusion under a 250-N axial load, ± 2.5 Nm of flexion/extension, and ± 2.5 Nm of lateral bend was 2.5% ± 1.9%, 2.5% ± 1.6%, and 1.5% ± 0.8%, respectively. Mean intervertebral foramen occlusion under a 250-N axial load, ± 2.5 Nm of flexion/extension, and ± 2.5 Nm of lateral bend was 7.8% ± 4.7%, 9.5% ± 5.7%, and 11.3% ± 6.2%, respectively. Conclusion Percent occlusion of the spinal canal and intervertebral foramen is dependent on magnitude and direction of load. Exiting neural elements at the location of the intervertebral foramen are the most vulnerable to impingement and generation of pain. PMID:25802663

  5. Levodopa-carbidopa with occlusion in older children with amblyopia.

    PubMed

    Bhartiya, Prashant; Sharma, Pradeep; Biswas, Nihar R; Tandon, Radhika; Khokhar, Sudarshan K

    2002-12-01

    To study the role of levodopa-carbidopa in supplementing occlusion therapy in older children with strabismic or anisometropic amblyopia. A clinical study was performed on 40 amblyopic children (19 strabismic and 21 anisometropic), 6 to 18 years old (mean age, 10.9 years). They received an average dose of 1.86 mg/kg/day (1.33-2.36 mg/kg/day) of levodopa and carbidopa (4:1 ratio) or a placebo in 3 divided doses over a 4-week period, combined with full-time occlusion. The occlusion was continued for the study duration of 3 months. Early Treatment Diabetic Retinopathy Study visual acuity charts and Cambridge low-contrast gratings for contrast sensitivity (CS) were used to assess visual functions. Tolerance and compliance with occlusion and capsule consumption were assessed. Visual acuity of the nonamblyopic eye did not deteriorate during the study in either group. CS decreased by 22 units in the levodopa group and increased in the placebo group by 53 units at the first month. The CS in the levodopa group recovered later by the third month of follow-up. Both the levodopa and the placebo groups showed significant improvement in visual function in the amblyopic eye (P <.001). Overall changes in logarithm of minimum angle of resolution values and CS in the amblyopic eyes were similar in both groups (P >.05). Strabismic and anisometropic amblyopes did not behave differently. Drug tolerance, occlusion compliance, and capsule ingestion compliance were similar between the groups, with no significant side effects. Clinically, levodopa supplementation does not offer any advantage over occlusion alone. Moreover, the risk of occlusion amblyopia could increase with the use of drugs like levodopa that might affect the plasticity of the visual cortex.

  6. Hypothalamic digoxin, hemispheric chemical dominance, and mesenteric artery occlusion.

    PubMed

    Kurup, Ravi Kumar; Kurup, Paramesware Achutha

    2003-12-01

    The role of the isoprenoid pathway in vascular thrombosis, especially mesenteric artery occlusion and its relation to hemispheric dominance, was assessed in this study. The following parameters were measured in patients with mesenteric artery occlusion and individuals with right hemispheric, left hemispheric, and bihemispheric dominance: (1) plasma HMG CoA reductase, digoxin, dolichol, ubiquinone, and magnesium levels; (2) tryptophan/tyrosine catabolic patterns; (3) free radical metabolism; (4) glycoconjugate metabolism; and (5) membrane composition. In patients with mesenteric artery occlusion there was elevated digoxin synthesis, increased dolichol and glycoconjugate levels, low ubiquinone, and elevated free radical levels. The RBC membrane Na(+)-K+ ATPase activity and serum magnesium were decreased. There was also an increase in tryptophan catabolites and reduction in tyrosine catabolites in the serum. There was an increase in cholesterol:phospholipid ratio and a reduction in glycoconjugate level of RBC membrane in these patients. The biochemical patterns obtained in mesenteric artery occlusion is similar to those obtained in left-handed/right hemispheric dominant individuals by the dichotic listening test. But all the patients with mesenteric artery occlusion were right-handed/left hemispheric dominant by the dichotic listening test. Hemispheric chemical dominance has no correlation with handedness or the dichotic listening test. Mesenteric artery occlusion occurs in right hemispheric chemically dominant individuals and is a reflection of altered brain function. Hemispheric chemical dominance may thus control the risk for developing vascular thrombosis in individuals.

  7. Increased carboxyhemoglobin level during liver resection with inflow occlusion.

    PubMed

    Godai, Kohei; Hasegawa-Moriyama, Maiko; Kuniyoshi, Tamotsu; Matsunaga, Akira; Kanmura, Yuichi

    2013-04-01

    Controlling stress responses associated with ischemic changes due to bleeding and ischemia/reperfusion injury is essential for anesthetic management. Endogenous carboxyhemoglobin (COHb) is produced in the oxidative degradation of heme proteins by the stress-response enzyme heme oxygenase. Although the COHb level is elevated in critically ill patients, changes in endogenous COHb during anesthesia have not been well investigated. Therefore, we evaluated changes in endogenous COHb levels in patients undergoing liver resections with inflow occlusion. Levels of COHb were significantly increased after the Pringle maneuver. The inflow occlusion time in patients with increased COHb after the Pringle maneuver (∆COHb > 0.3 %) was significantly longer than in patients without increased COHb (∆COHb < 0.3 %) (P = 0.01). In addition, COHb changes were correlated with inflow occlusion time (P = 0.005, R(2) = 0.21). Neither total blood loss, transfusion volume of packed red blood cells, operation time, nor anesthetic time differed between patients with and without increased COHb. The results indicated that endogenous COHb levels were increased by inflow occlusion in patients undergoing liver resections, which suggests that changes in COHb may correlate with hepatic ischemia/reperfusion injury induced by inflow occlusion.

  8. Complete occlusion after blunt injury to the abdominal aorta.

    PubMed

    Meghoo, Colin A L; Gonzalez, Ernest A; Tyroch, Alan H; Wohltmann, Christopher D

    2003-10-01

    Injury to the abdominal aorta after blunt trauma is uncommon. When this injury results in complete vessel occlusion, the presentation is dramatic. Timely intervention is essential. After a case report, we examined all reported cases of complete occlusion after blunt injury to the abdominal aorta and reviewed the cause, presentation, and management of this injury. Complete vessel occlusion arises from intimal injury. The most frequent mechanism is compression from a seat belt or steering wheel during a motor vehicle crash. Patients present with absent femoral and distal pulses in association with lower extremity neuropathy. Intervention commonly involves bypass grafting of the abdominal aorta. Complete occlusion after blunt trauma to the abdominal aorta is rare. Neurologic deficits most commonly arise from peripheral nerve ischemia. Reperfusion within 6 hours confers a greater chance of limb salvage and neurologic recovery.

  9. Aphid watery saliva counteracts sieve-tube occlusion: a universal phenomenon?

    PubMed

    Will, Torsten; Kornemann, Sarah R; Furch, Alexandra C U; Tjallingii, W Fred; van Bel, Aart J E

    2009-10-01

    Ca2+-binding proteins in the watery saliva of Megoura viciae counteract Ca2+-dependent occlusion of sieve plates in Vicia faba and so prevent the shut-down of food supply in response to stylet penetration. The question arises whether this interaction between aphid saliva and sieve-element proteins is a universal phenomenon as inferred by the coincidence between sieve-tube occlusion and salivation. For this purpose, leaf tips were burnt in a number of plant species from four different families to induce remote sieve-plate occlusion. Resultant sieve-plate occlusion in these plant species was counteracted by an abrupt switch of aphid behaviour. Each of the seven aphid species tested interrupted its feeding behaviour and started secreting watery saliva. The protein composition of watery saliva appeared strikingly different between aphid species with less than 50% overlap. Secretion of watery saliva seems to be a universal means to suppress sieve-plate occlusion, although the protein composition of watery saliva seems to diverge between species.

  10. Contact with turf algae alters the coral microbiome: contact versus systemic impacts

    NASA Astrophysics Data System (ADS)

    Pratte, Zoe A.; Longo, Guilherme O.; Burns, Andrew S.; Hay, Mark E.; Stewart, Frank J.

    2018-03-01

    Coral reefs are degrading to algae-dominated reefs worldwide, with alterations of coral microbiomes commonly co-occurring with reef demise. The severe thermal anomaly during the 2016 El Niño event in the South Pacific killed many corals and stressed others. We examined the microbiome of turf algae and of the coral Porites sp. in contact with turf during this thermal event to investigate algal turf effects on the coral microbiome during a period of environmental stress. The microbial composition of turf did not differ between coral-contacted and non-contacted turfs. However, microbiomes of corals in direct contact with turf were similar to those of the turf microbiome, but differed significantly from coral portions 5 cm from the point of turf/coral contact and from portions of the coral that looked most healthy, regardless of location. Although the majority of significant differences occurred in coral samples at the point of contact, a small subset of microbial taxa was enriched in coral tissues taken 5 cm from turf contact compared to all other sample types, including samples from areas of the coral that appeared most healthy. These results suggest that the coral microbiome is susceptible to colonization by microbes from turf, but not vice versa. Results also suggest that algal contact elicits a subtle shift in the coral microbiome just beyond the contact site. The combination of turf microbiome stability and coral microbiome vulnerability at areas of contact may contribute to the continued decline in coral cover and increase in algal cover associated with coral-algae phase shifts.

  11. Vertical dimensional stability and rigidity of occlusal registration materials.

    PubMed

    Walker, Mary P; Wu, Edis; Heckman, M Elizabeth; Alderman, Nicholas

    2009-01-01

    Dimensionally accurate occlusal registration records are essential for restorative dentistry; moreover, since records are not used immediately or may be used more than once, the registration material should exhibit accuracy over time (a concept known as dimensional stability). It has been speculated that materials with increased hardness or rigidity should produce more accurate registration records due to an increased resistance to distortion. This study compared the rigidity and associated dimensional accuracy of a recently marketed bisacrylic occlusal registration material and a vinyl polysiloxane (VPS). Maxillary and mandibular typodont arches were mounted on a plasterless articulator from which teeth No. 3, 13, and 15 had been removed to simulate edentulous spaces. After preparing teeth No. 2, 4, 12, and 14 as bridge abutments, the remaining teeth were equilibrated selectively to produce even anterior contact. Four digital photographs were taken to make vertical interarch measurements at four locations (teeth No. 3, 7, 10, and 14). Following initial photos (controls), 10 interocclusal records were made using each registration material, with material placed only in the segments in which teeth were prepared. The records were used for mounting the maxillary arch against the mandibular arch after 48, 72, and 120 hours. There were significant effects on vertical dimensional change related to arch location, material, and mounting time. Both materials demonstrated significantly larger posterior vertical openings than anterior vertical openings, while the bisacrylate produced a larger posterior opening than VPS at 48 and 72 hours and a larger anterior opening at all mounting times. There also was a significant difference in hardness/rigidity due to material and measurement time; at all measurement times, bisacrylate exhibited a significantly higher hardness number.

  12. Prehospital Acute Stroke Severity Scale to Predict Large Artery Occlusion: Design and Comparison With Other Scales.

    PubMed

    Hastrup, Sidsel; Damgaard, Dorte; Johnsen, Søren Paaske; Andersen, Grethe

    2016-07-01

    We designed and validated a simple prehospital stroke scale to identify emergent large vessel occlusion (ELVO) in patients with acute ischemic stroke and compared the scale to other published scales for prediction of ELVO. A national historical test cohort of 3127 patients with information on intracranial vessel status (angiography) before reperfusion therapy was identified. National Institutes of Health Stroke Scale (NIHSS) items with the highest predictive value of occlusion of a large intracranial artery were identified, and the most optimal combination meeting predefined criteria to ensure usefulness in the prehospital phase was determined. The predictive performance of Prehospital Acute Stroke Severity (PASS) scale was compared with other published scales for ELVO. The PASS scale was composed of 3 NIHSS scores: level of consciousness (month/age), gaze palsy/deviation, and arm weakness. In derivation of PASS 2/3 of the test cohort was used and showed accuracy (area under the curve) of 0.76 for detecting large arterial occlusion. Optimal cut point ≥2 abnormal scores showed: sensitivity=0.66 (95% CI, 0.62-0.69), specificity=0.83 (0.81-0.85), and area under the curve=0.74 (0.72-0.76). Validation on 1/3 of the test cohort showed similar performance. Patients with a large artery occlusion on angiography with PASS ≥2 had a median NIHSS score of 17 (interquartile range=6) as opposed to PASS <2 with a median NIHSS score of 6 (interquartile range=5). The PASS scale showed equal performance although more simple when compared with other scales predicting ELVO. The PASS scale is simple and has promising accuracy for prediction of ELVO in the field. © 2016 American Heart Association, Inc.

  13. Clinical outcomes in middle cerebral artery trunk occlusions versus secondary division occlusions after mechanical thrombectomy: pooled analysis of the Mechanical Embolus Removal in Cerebral Ischemia (MERCI) and Multi MERCI trials.

    PubMed

    Shi, Zhong-Song; Loh, Yince; Walker, Gary; Duckwiler, Gary R

    2010-05-01

    The benefit of endovascular revascularization of patients with acute ischemic stroke with middle cerebral artery (MCA) secondary division (M2) occlusions as compared with MCA trunk (M1) occlusions is not known. In this analysis, we compared revascularization status and clinical outcomes in patients with angiographically confirmed MCA M1 versus isolated M2 occlusions treated with mechanical thrombectomy using the Merci Retriever devices. We retrospectively analyzed the pooled data of patients with MCA strokes from the Mechanical Embolus Removal in Cerebral Ischemia (MERCI) and Multi MERCI trials. Patient data were dichotomized into 2 groups: MCA M1 occlusions and isolated M2 occlusions. Baseline characteristics, revascularization rates, hemorrhage rates, complications, outcomes, and mortality were evaluated for both groups. Of 178 patients with MCA occlusion treated in the MERCI and Multi MERCI trials, 84.3% had M1 lesions and 15.7% had isolated M2 lesions. Patients with isolated M2 occlusions were revascularized at a higher rate, required a lower mean number of passes, and were associated with a trend toward shorter mean procedure time than patients with M1 occlusions. No statistically significant differences were found between M2 and M1 groups for symptomatic hemorrhage, clinically significant procedural adverse events, favorable 90-day outcome, or 90-day mortality, although in all instances, the M2 outcomes were numerically better than those in M1 subjects. In multivariate analysis, final revascularization was the strongest independent predictor of good outcome at 90 days. Patients with both MCA M1 occlusions and isolated M2 occlusions can achieve a relatively high rate of revascularization and favorable clinical outcomes after mechanical thrombectomy. In fact, patients with isolated M2 occlusions had a higher rate of revascularization, required fewer passes, and had no increased complications compared with patients with M1 occlusions.

  14. [Occlusion and posture: is there evidence of correlation?].

    PubMed

    Michelotti, A; Manzo, P; Farella, M; Martina, R

    1999-11-01

    The observation that the masticatory system and the postural body regulating system are anatomically and functionally related, has led to postulate several hypotheses of correlation between occlusal and postural disturbances. In the last decade, these arguments have gained a great social impact, also because they have been broadly spread by the mass-media. As a consequence, there has been a growing number of patients seeking concomitant occlusal and postural treatments. The aim of this study was to review critically the current evidence of correlation between the two systems; this in order to address clinical issues for the management of patients. Methodology of the studies reviewed has been evaluated according to the criteria suggested by Storey and Rugh 20 rif. Although there are some evidences of correlation between occlusion and posture, this appears limited to the cranio-cervical tract of the column and tends to disappear when descending in cranio-caudal direction. On the basis of this review of the literature, it's not advisable to treat postural imbalance by means of occlusal treatment or vice versa, particularly if the therapeutic modalities are irreversible.

  15. Intrarenal hemodynamic changes following acute partial renal arterial occlusion.

    DOT National Transportation Integrated Search

    1965-10-01

    Both an increase and a decrease in total renal vascular resistance, following a period of total renal artery occlusion, have been reported from this laboratory. The duration of the occlusive period and height of the perfusion pressure were found to p...

  16. Pulmonary veno-occlusive disease

    MedlinePlus

    ... disorder. Alternative Names Pulmonary vaso-occlusive disease Images Respiratory system References Chin K, Channick RN. Pulmonary hypertension. In: Broaddus VC, Mason RJ, Ernst JD, et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016: ...

  17. What Governs Friction of Silicon Oxide in Humid Environment: Contact Area between Solids, Water Meniscus around the Contact, or Water Layer Structure?

    PubMed

    Chen, Lei; Xiao, Chen; Yu, Bingjun; Kim, Seong H; Qian, Linmao

    2017-09-26

    In order to understand the interfacial parameters governing the friction force (F t ) between silicon oxide surfaces in humid environment, the sliding speed (v) and relative humidity (RH) dependences of F t were measured for a silica sphere (1 μm radius) sliding on a silicon oxide (SiO x ) surface, using atomic force microscopy (AFM), and analyzed with a mathematical model describing interfacial contacts under a dynamic condition. Generally, F t decreases logarithmically with increasing v to a cutoff value below which its dependence on interfacial chemistry and sliding condition is relatively weak. Above the cutoff value, the logarithmic v dependence could be divided into two regimes: (i) when RH is lower than 50%, F t is a function of both v and RH; (ii) in contrast, at RH ≥ 50%, F t is a function of v only, but not RH. These complicated v and RH dependences were hypothesized to originate from the structure of the water layer adsorbed on the surface and the water meniscus around the annulus of the contact area. This hypothesis was tested by analyzing F t as a function of the water meniscus area (A m ) and volume (V m ) estimated from a thermally activated water-bridge formation model. Surprisingly, it was found that F t varies linearly with V m and correlates poorly with A m at RH < 50%; and then its V m dependence becomes weaker as RH increases above 50%. Comparing the friction data with the attenuated total reflection infrared (ATR-IR) spectroscopy analysis result of the adsorbed water layer, it appeared that the solidlike water layer structure formed on the silica surface plays a critical role in friction at RH < 50% and its contribution diminishes at RH ≥ 50%. These findings give a deeper insight into the role of water condensation in friction of the silicon oxide single asperity contact under ambient conditions.

  18. Continuous full-time occlusion of the sound eye vs full-time occlusion of the sound eye periodically alternating with occlusion of the amblyopic eye in treatment of amblyopia: a prospective randomized study.

    PubMed

    Stanković, B; Milenković, S

    2007-01-01

    To compare continuous full-time (24 hours per day) occlusion of the sound eye with full-time occlusion (24 hours per day) of the sound eye 1 day more than the years of age periodically alternating with occlusion of the amblyopic eye for 1 day, as treatments for profound strabismic amblyopia in children older than 5 years. A total of 53 patients with visual acuity (VA) of 0.4 and less in the amblyopic eye (tested by crowded Landolt Cs) after previously being provided optimal optical correction were randomly assigned to receive either of the two patching regimens. VA and pattern reversal visual evoked potentials (PVEP) were recorded prospectively at 1-month intervals. Improvement in VA and the reduction in crowding difficulties (CD) were the main outcome measures of the treatment efficiency. Both treatment modalities were equally effective. Of the 51 subjects who completed the study, 21 (41.2%) were cured whereas 32 (62.7%) attained satisfactory improvement. Recovery of VA was related to age, with cure being obtained in 23.5% (4/17) and satisfactory improvement in 52.9% (9/17) of patients older than 9 years. Larger gain in VA influenced the stability of the vision over time. It can be concluded that in clinically monitored parameters both treatment modalities were equally effective without any statistical or clinical significance in the observed groups of patients. However, events like the "trade-off" effect, occurrence of occlusion amblyopia, or prolongation of PVEP latency of the sound eye indicate that full-time continuous occlusion possibly presents a more effective form of treatment.

  19. ACUTE RETINAL ARTERIAL OCCLUSIVE DISORDERS

    PubMed Central

    Hayreh, Sohan Singh

    2011-01-01

    The initial section deals with basic sciences; among the various topics briefly discussed are the anatomical features of ophthalmic, central retinal and cilioretinal arteries which may play a role in acute retinal arterial ischemic disorders. Crucial information required in the management of central retinal artery occlusion (CRAO) is the length of time the retina can survive following that. An experimental study shows that CRAO for 97 minutes produces no detectable permanent retinal damage but there is a progressive ischemic damage thereafter, and by 4 hours the retina has suffered irreversible damage. In the clinical section, I discuss at length various controversies on acute retinal arterial ischemic disorders. Classification of acute retinal arterial ischemic disorders These are of 4 types: CRAO, branch retinal artery occlusion (BRAO), cotton wools spots and amaurosis fugax. Both CRAO and BRAO further comprise multiple clinical entities. Contrary to the universal belief, pathogenetically, clinically and for management, CRAO is not one clinical entity but 4 distinct clinical entities – non-arteritic CRAO, non-arteritic CRAO with cilioretinal artery sparing, arteritic CRAO associated with giant cell arteritis (GCA) and transient non-arteritic CRAO. Similarly, BRAO comprises permanent BRAO, transient BRAO and cilioretinal artery occlusion (CLRAO), and the latter further consists of 3 distinct clinical entities - non-arteritic CLRAO alone, non-arteritic CLRAO associated with central retinal vein occlusion and arteritic CLRAO associated with GCA. Understanding these classifications is essential to comprehend fully various aspects of these disorders. Central retinal artery occlusion The pathogeneses, clinical features and management of the various types of CRAO are discussed in detail. Contrary to the prevalent belief, spontaneous improvement in both visual acuity and visual fields does occur, mainly during the first 7 days. The incidence of spontaneous visual

  20. A new surgical approach for punctal occlusion using fibrous tissue from under the lacrimal caruncle

    PubMed Central

    Yokoi, Norihiko; Komuro, Aoi; Sotozono, Chie; Kinoshita, Shigeru

    2018-01-01

    Purpose Surgical punctal occlusion is indispensable for the treatment of severe dry eye in cases where punctal-plug insertion is not applicable due to an enlarged or deformed punctum. However, permanent punctal occlusion is difficult in some cases. In our aim to establish a more reliable punctal occlusion, we have devised a new surgical approach for punctal occlusion. Patients and methods This study involved 20 puncta of 12 eyes of 12 patients (1 male and 11 females; mean age: 65.2 years) with severe aqueous-tear-deficient dry eye. A new surgical procedure for punctal occlusion using fibrous tissue from under the lacrimal caruncle into the diathermy-induced deepithelialized canaliculus as supporting tissue for punctal closure was performed. In all patients, the assessment of eye symptoms, as well as the condition of punctal occlusion by slit-lamp biomicroscopy, tear volume (tear-meniscus radius [TMR] measurement by meniscometry), the condition of precorneal tear film (graded by interferometry [IG]), measurement of fluorescein breakup time (FBUT), and scoring of ocular surface staining (fluorescein score of area [FSA] and density [FSD], and lissamine green score [LGS]) were performed, and the preoperative and 6-month-postoperative values were compared. Results In regard to the postoperative improvement of symptoms, 11 patients showed remarkable improvement, 1 patient showed improvement, and no reopening of the closed punctum was found in any patient. Test values were all significantly improved post surgery (all: P<0.05) as compared to those prior to surgery (respective values [mean ± SD], and the pre- and postoperative P-values were: TMR (mm) [0.18±0.08; 0.56±0.28, P=0.002], IG [4.3±0.9; 2.7±0.8, P=0.009], FBUT [0.4±0.6; 4.1±2.9, P=0.004], FSA [1.6±0.7; 0.7±0.9, P=0.03], FSD [2.7±0.7; 0.6±0.7, P=0.003], and LGS [5.1±2.7; 1.1±2.1, P=0.005]). Moreover, no postoperative complications were observed. Conclusion The findings of this study showed that our

  1. Contact Tracing during an Outbreak of Ebola Virus Disease in the Western Area Districts of Sierra Leone: Lessons for Future Ebola Outbreak Response.

    PubMed

    Olu, Olushayo Oluseun; Lamunu, Margaret; Nanyunja, Miriam; Dafae, Foday; Samba, Thomas; Sempiira, Noah; Kuti-George, Fredson; Abebe, Fikru Zeleke; Sensasi, Benjamin; Chimbaru, Alexander; Ganda, Louisa; Gausi, Khoti; Gilroy, Sonia; Mugume, James

    2016-01-01

    Contact tracing is a critical strategy required for timely prevention and control of Ebola virus disease (EVD) outbreaks. Available evidence suggests that poor contact tracing was a driver of the EVD outbreak in West Africa, including Sierra Leone. In this article, we answered the question as to whether EVD contact tracing, as practiced in Western Area (WA) districts of Sierra Leone from 2014 to 2015, was effective. The goal is to describe contact tracing and identify obstacles to its effective implementation. Mixed methods comprising secondary data analysis of the EVD case and contact tracing data sets collected from WA during the period from 2014 to 2015, key informant interviews of contact tracers and their supervisors, and a review of available reports on contact tracing were implemented to obtain data for this study. During the study period, 3,838 confirmed cases and 32,706 contacts were listed in the viral hemorrhagic fever and contact databases for the district (mean 8.5 contacts per case). Only 22.1% (852) of the confirmed cases in the study area were listed as contacts at the onset of their illness, which indicates incomplete identification and tracing of contacts. Challenges associated with effective contact tracing included lack of community trust, concealing of exposure information, political interference with recruitment of tracers, inadequate training of contact tracers, and incomplete EVD case and contact database. While the tracers noted the usefulness of community quarantine in facilitating their work, they also reported delayed or irregular supply of basic needs, such as food and water, which created resistance from the communities. Multiple gaps in contact tracing attributed to a variety of factors associated with implementers, and communities were identified as obstacles that impeded timely control of the EVD outbreak in the WA of Sierra Leone. In future outbreaks, early community engagement and participation in contact tracing, establishment of

  2. New approach for pattern collapse problem by increasing contact area at sub-100nm patterning

    NASA Astrophysics Data System (ADS)

    Lee, Sung-Koo; Jung, Jae Chang; Lee, Min Suk; Lee, Sung K.; Kim, Sam Young; Hwang, Young-Sun; Bok, Cheol K.; Moon, Seung-Chan; Shin, Ki S.; Kim, Sang-Jung

    2003-06-01

    To accomplish minimizing feature size to sub 100nm, new light sources for photolithography are emerging, such as ArF(193nm), F2(157nm), and EUV(13nm). However as the pattern size decreases to sub 100nm, a new obstacle, that is pattern collapse problem, becomes most serious bottleneck to the road for the sub 100 nm lithography. The main reason for this pattern collapse problem is capillary force that is increased as the pattern size decreases. As a result there were some trials to decrease this capillary force by changing developer or rinse materials that had low surface tension. On the other hands, there were other efforts to increase adhesion between resists and sub materials (organic BARC). In this study, we will propose a novel approach to solve pattern collapse problems by increasing contact area between sub material (organic BARC) and resist pattern. The basic concept of this approach is that if nano-scale topology is made at the sub material, the contact area between sub materials and resist will be increased. The process scheme was like this. First after coating and baking of organic BARC material, the nano-scale topology (3~10nm) was made by etching at this organic BARC material. On this nano-scale topology, resist was coated and exposed. Finally after develop, the contact area between organic BARC and resist could be increased. Though nano-scale topology was made by etching technology, this 20nm topology variation induced large substrate reflectivity of 4.2% and as a result the pattern fidelity was not so good at 100nm 1:1 island pattern. So we needed a new method to improve pattern fidelity problem. This pattern fidelity problem could be solved by introducing a sacrificial BARC layer. The process scheme was like this. First organic BARC was coated of which k value was about 0.64 and then sacrificial BARC layers was coated of which k value was about 0.18 on the organic BARC. The nano-scale topology (1~4nm) was made by etching of this sacrificial BARC layer

  3. Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.

    PubMed

    Sunaga, Akihiro; Masuda, Masaharu; Asai, Mitsutoshi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Syota; Mano, Toshiaki

    2018-04-10

    Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media. Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation. We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%. Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.

  4. Fracture analysis of randomized implant-supported fixed dental prostheses

    PubMed Central

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and

  5. Amplatzer vascular plug for rapid vessel occlusion in interventional neuroradiology

    PubMed Central

    Banfield, Jillian C

    2016-01-01

    The purpose of this paper is to report different uses of endovascular Amplatzer vascular plug (AVP) treatment for rapid vessel occlusion in the field of interventional neuroradiology. We retrospectively reviewed our interventional neuroradiology database from November 2010 to July 2015 and found nine patients who were treated with endovascular AVP. AVP was used for rapid vessel occlusion of common carotid artery (1 patient), internal carotid artery (5 patients), vertebral artery (2 patients), and internal jugular vein (1 patient). A median of three AVPs were used with almost immediate occlusion and no thromboembolic complications. Use of AVP is feasible, safe, rapid, and potentially cost-effective method for rapid occlusion of larger size vessels in the head and neck region for different indications. PMID:26515699

  6. Microfluidics for investigating vaso-occlusions in sickle cell disease.

    PubMed

    Horton, Renita E

    2017-07-01

    SCD stems from amutation in the beta globin gene. Upon deoxygenation, hemoglobin polymerizes and triggers RBC remodeling. This phenomenon is central to SCD pathogenesis as individuals suffering from the disease are plagued by painful vaso-occlusive crises episodes. These episodes are the result of a combination of processes including inflammation, thrombosis, and blood cell adhesion to the vascular wall which leads to blockages within the vasculature termed vaso-occlusions. Vaso-occlusive episodes deprive tissues of oxygen and are a major contributor to SCD-related complications; unfortunately, the complex mechanisms that contribute to vaso-occlusions are not well understood. Vaso-occlusions can occur in post-capillary venules; hence, the microvasculature is a prime target for SCD therapies. Traditional in vitro systems poorly recapitulate architectural and dynamic flow properties of in vivo systems. However, microfluidic devices can capture features of the native vasculature such as cellular composition, flow, geometry, and ECM presentation. This review, although not comprehensive, highlights microfluidic approaches that aim to improve our current understanding of the pathophysiological mechanisms surrounding SCD. Microfluidic platforms can aid in identifying factors that may contribute to disease severity and can serve as suitable test beds for novel treatment strategies which may improve patient outcomes. © 2017 John Wiley & Sons Ltd.

  7. Influence of occlusal loading on peri-implant clinical parameters. A pilot study

    PubMed Central

    Pellicer-Chover, Hilario; Viña-Almunia, José; Romero-Millán, Javier; Peñarrocha-Oltra, David; Peñarrocha-Diago, María

    2014-01-01

    Objectives: To investigate the relation between occlusal loading and peri-implant clinical parameters (probing depth, bleeding on probing, gingival retraction, width of keratinized mucosa, and crevicular fluid volume) in patients with implant-supported complete fixed prostheses in both arches. Material and Methods: This clinical study took place at the University of Valencia (Spain) dental clinic. It included patients attending the clinic for regular check-ups during at least 12 months after rehabilitation of both arches with implant-supported complete fixed ceramo-metallic prostheses. One study implant and one control implant were established for each patient using the T-Scan®III computerized system (Tesco, South Boston, USA). The maxillary implant closest to the point of maximum occlusal loading was taken as the study implant and the farthest (with least loading) as the control. Occlusal forces were registered with the T-Scan® III and then occlusal adjustment was performed to distribute occlusal forces correctly. Peri-implant clinical parameters were analyzed in both implants before and two and twelve months after occlusal adjustment. Results: Before occlusal adjustment, study group implants presented a higher mean volume of crevicular fluid (51.3±7.4 UP) than the control group (25.8±5.5 UP), with statistically significant difference. Two months after occlusal adjustment, there were no significant differences between groups (24.6±3.8 UP and 26±4.5 UP respectively) (p=0.977). After twelve months, no significant differences were found between groups (24.4±11.1 UP and 22.5±8.9 UP respectively) (p=0.323). For the other clinical parameters, no significant differences were identified between study and control implants at any of the study times (p>0.05). Conclusions: Study group implants receiving higher occlusal loading presented significantly higher volumes of crevicular fluid than control implants. Crevicular fluid volumes were similar in both groups two and

  8. The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilic, Nikola, E-mail: fosafosa75@yahoo.com; Davidovic, Lazar; Koncar, Igor

    Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographicmore » evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.« less

  9. The muscle engram: the reflex that limits conventional occlusal treatment.

    PubMed

    Lerman, Martin D

    2011-10-01

    The engram (the masticatory "muscle memory") is shown to be a conditionable reflex whose muscle conditioning lasts less than two minutes, far shorter than previously thought. This reflex, reinforced and stored in the masticatory muscles at every swallow, adjusts masticatory muscle activity to guide the lower arch unerringly into its ICP. These muscle adjustments compensate for the continually changing intemal and external factors that affect the mandible's entry into the ICP. A simple quick experiment described in this article isolates the engram, enabling the reader to see its action clearly for the first time. It is urged that every reader perform this experiment. This experiment shows how the engram, by hiding the masticatory muscles' reaction (the hit-and-slide), limits the success of the therapist in achieving occlusion-muscle compatibility. This finding has major clinical implications. It means that, as regards the muscle aspect of treating occlusion, the dentist treating occlusion conventionally is working blind, a situation the neuromuscular school of occlusal thought seeks to correct. The controversy over occlusion continues.

  10. A study of parallelism of the occlusal plane and ala-tragus line.

    PubMed

    Sadr, Katayoun; Sadr, Makan

    2009-01-01

    Orientation of the occlusal plane is one of the most important clinical procedures in prostho-dontic rehabilitation of edentulous patients. The aim of this study was to define the best posterior reference point of ala-tragus line for orientation of occlusal plane for complete denture fabrication. Fifty-three dental students (27 females and 26 males) with complete natural dentition and Angel's Class I occlusal relationship were selected. The subjects were photographed in natural head position while clenching on a Fox plane. After tracing the photographs, the angles between the following lines were measured: the occlusal plane (Fox plane) and the superior border of ala-tragus, the occlusal plane (Fox plane) and the middle of ala-tragus as well as the occlusal plane (Fox plane) and the inferior border of ala-tragus. Descriptive statistics, one sample t-test and independent t-test were used. P value less than 0.05 was considered significant. There was no parallelism between the occlusal plane and ala-tragus line with three different posterior ends and one sample t-test showed that the angles between them were significantly different from zero (p<0.05). However, the supe-rior border of ala-tragus line had the lowest mean angle, 1.80° (3.12) and was almost parallel to the occlusal plane. The superior border of the tragus is suggested as the posterior reference for ala-tragus line.

  11. Novel Evidence-Based Classification of Cavernous Venous Occlusive Disease.

    PubMed

    Pathak, Ram A; Rawal, Bhupendra; Li, Zhuo; Broderick, Gregory A

    2016-10-01

    The primary aim of our study was to determine whether an evidence-based rationale could categorize cavernous venous occlusive disease into mild, moderate and severe erectile dysfunction. A total of 863 patients underwent color duplex Doppler ultrasound from January 2010 to June 2013 performed by a single urologist. We identified a cohort of 75 patients (8.7%) with a diagnosis of cavernous venous occlusive disease based on a unilateral resistive index less than 0.9, and right and left peak systolic velocity 35 cm per second or less after visual sexual stimulation. At a median followup of 13 months patients were evaluated for treatment efficacy. A total of 75 patients with a median age of 60 years (range 19 to 83) and a mean body mass index of 26.3 kg/m(2) (range 19.0 to 39.3) satisfied the criteria of cavernous venous occlusive disease. When substratified into tertiles, resistive index cutoffs were obtained, including mild cavernous venous occlusive disease-81.6 to 94.0, moderate disease-72.6 to 81.5 and severe disease-59.5 to 72.5. Using these 3 groups the phosphodiesterase type 5-inhibitor failure rate (p = 0.017) and SHIM (Sexual Health Inventory for Men) score categories (1 to 10 vs 11 to 20, p = 0.030) were statistically significantly different for mild, moderate and severe cavernous venous occlusive disease. Treatment satisfaction was also statistically significantly different. Penile prosthetic placement was a more common outcome among patients with erectile dysfunction and more severe cavernous venous occlusive disease. Our retrospective analysis supports a correlation between the phosphodiesterase type 5 inhibitor failure rate, SHIM score and the rate of surgical intervention using resistive index values. Our data further suggest that an evidence-based classification of cavernous venous occlusive disease by color Doppler ultrasound is possible and can triage patients to penile prosthetic placement. Copyright © 2016 American Urological Association

  12. Fluoroscopy-free Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for controlling life threatening postpartum hemorrhage

    PubMed Central

    Stensaeth, Knut Haakon; Sovik, Edmund; Haig, Ingrid Natasha Ylva; Skomedal, Erna; Jorgensen, Arve

    2017-01-01

    Background Severe postpartum hemorrhage occurs in 1/1000 women giving birth. This condition is often dramatic and may be life threatening. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) has in recent years been introduced as a novel treatment for hemorrhagic shock. We present a series of fluoroscopy-free REBOA for controlling life threatening postpartum hemorrhage. Methods In 2008 an ‘aortic occlusion kit’ was assembled and used in three Norwegian university hospitals. The on-call interventional radiologist (IR) was to be contacted with a response time < 30 minutes in case of life threatening PPH. Demographics and characteristics were noted from the medical records. Results This retrospective study includes 36 patients treated with fluoroscopy-free REBOA for controlling severe postpartum hemorrhage in the years 2008–2015. The REBOA success rate was 100% and no patients died from REBOA related complications. Uterine artery embolization was performed in 17 (47%) patients and a hysterectomy in 16 (44%) patients. A short (11cm) introducer length was strongly associated with iliac artery thrombus formation (ρ = 0.50, P = 0.002). In addition, there was a strong negative correlation between uterine artery embolization and hysterectomy (ρ = -0.50, P = 0.002). Conclusions Our Norwegian experience indicates the clinical safety and feasibility of REBOA in life threatening PPH. Also, REBOA can be used in an emergency situation without the use of fluoroscopy with a high degree of technical success. It is important that safety implementation of REBOA is established, especially through limited aortic balloon occlusion time and a thorough balloon deflation regime. PMID:28355242

  13. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    PubMed

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  14. Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients.

    PubMed

    Thanathornwong, Bhornsawan; Suebnukarn, Siriwan

    2017-10-01

    The aim of this study was to develop a decision support model for the prediction of occlusal force from the size and color of articulating paper markings in bruxism patients. We used the information from the datasets of 30 bruxism patients in which digital measurements of the size and color of articulating paper markings (12-µm Hanel; Coltene/Whaledent GmbH, Langenau, Germany) on canine protected hard stabilization splints were measured in pixels (P) and in red (R), green (G), and blue (B) values using Adobe Photoshop software (Adobe Systems, San Jose, CA, USA). The occlusal force (F) was measured using T-Scan III (Tekscan Inc., South Boston, MA, USA). The multiple regression equation was applied to predict F from the P and RGB. Model evaluation was performed using the datasets from 10 new patients. The patient's occlusal force measured by T-Scan III was used as a 'gold standard' to compare with the occlusal force predicted by the multiple regression model. The results demonstrate that the correlation between the occlusal force and the pixels and RGB of the articulating paper markings was positive (F = 1.62×P + 0.07×R -0.08×G + 0.08×B + 4.74; R 2 = 0.34). There was a high degree of agreement between the occlusal force of the patient measured using T-Scan III and the occlusal force predicted by the model (kappa value = 0.82). The results obtained demonstrate that the multiple regression model can predict the occlusal force using the digital values for the size and color of the articulating paper markings in bruxism patients.

  15. Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients

    PubMed Central

    Thanathornwong, Bhornsawan

    2017-01-01

    Objectives The aim of this study was to develop a decision support model for the prediction of occlusal force from the size and color of articulating paper markings in bruxism patients. Methods We used the information from the datasets of 30 bruxism patients in which digital measurements of the size and color of articulating paper markings (12-µm Hanel; Coltene/Whaledent GmbH, Langenau, Germany) on canine protected hard stabilization splints were measured in pixels (P) and in red (R), green (G), and blue (B) values using Adobe Photoshop software (Adobe Systems, San Jose, CA, USA). The occlusal force (F) was measured using T-Scan III (Tekscan Inc., South Boston, MA, USA). The multiple regression equation was applied to predict F from the P and RGB. Model evaluation was performed using the datasets from 10 new patients. The patient's occlusal force measured by T-Scan III was used as a ‘gold standard’ to compare with the occlusal force predicted by the multiple regression model. Results The results demonstrate that the correlation between the occlusal force and the pixels and RGB of the articulating paper markings was positive (F = 1.62×P + 0.07×R –0.08×G + 0.08×B + 4.74; R2 = 0.34). There was a high degree of agreement between the occlusal force of the patient measured using T-Scan III and the occlusal force predicted by the model (kappa value = 0.82). Conclusions The results obtained demonstrate that the multiple regression model can predict the occlusal force using the digital values for the size and color of the articulating paper markings in bruxism patients. PMID:29181234

  16. Effectiveness of various toothpastes on dentine tubule occlusion.

    PubMed

    Arnold, W H; Prange, M; Naumova, E A

    2015-04-01

    Dentine hypersensitivity is an increasing problem in dentistry. Several products are available that claim to occlude open dentine tubules and to reduce dentine hypersensitivity. The aim of this study was to investigate the effectiveness of several different products on dentine tubule occlusion using qualitative and quantitative methods. Dentine discs were prepared from extracted human premolars and molars. The dentine discs were brushed with 6 different experimental toothpastes, 1 positive control toothpaste and 1 negative control without toothpaste; the brushing simulated a total brushing time of 1 year. Half of the discs were etched with lemon juice after toothpaste application. Standardized scanning electron microphotographs were taken and converted into binary black and white images. The black pixels, which represented the open dentine tubules, were counted and statistically evaluated. Then, half of the dentine discs were broken, and the occlusion of the dentine tubules was investigated using energy dispersive X-ray spectroscopy (EDS). The number of open dentine tubules decreased significantly after brushing with 5 of the 6 tested toothpastes. A significant effect was observed after acid erosion for 3 of the 6 tested toothpastes. EDS revealed partly closed dentine tubules after brushing with 3 toothpastes; however, no partly closed dentine tubules were observed after acid erosion. Some toothpastes are capable of partial dentine tubule occlusion. This occlusion is unstable and can be removed with acid erosion. Desensitizing toothpastes are the most common products that are used against dentine hypersensitivity, and these toothpastes affect dentine tubule occlusion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Laparoscopic uterine artery occlusion for symptomatic leiomyomas.

    PubMed

    Lichtinger, Moises; Hallson, Laurey; Calvo, Patricia; Adeboyejo, Ghea

    2002-05-01

    To describe a laparoscopic technique that safely occludes both uterine arteries, overcoming an altered surgical field resulting from scarring and/or uterine leiomyomatous growth. Prospective analysis (Canadian Task Force classification II-2). Nonprofit community hospital. Eight women with leiomyomas with abnormal uterine bleeding, pelvic pain or pressure, and/or anemia. Bilateral laparoscopic retroperitoneal uterine artery occlusion. Occlusion at the initial track of the uterine artery was performed by laparoscopic coated ligature in six patients. In two obese patients with deep retroperitoneal space, vascular clips were placed endoscopically using the same dissecting technique. All patients were discharged within 20 hours after the procedure. All five women with abnormal bleeding reported satisfactory decrease; none reported amenorrhea. Of eight with preoperative pain or pressure, seven reported complete disappearance and one significant relief. All three patients with anemia had normal red cell counts after 1 month. Laparoscopic uterine artery occlusion using a lateral retroperitoneal technique is safe and effective in women with pelvic scarring and altered pelvic anatomy.

  18. Direct observation of mineral–organic composite formation reveals occlusion mechanism

    DOE PAGES

    Cho, Kang Rae; Kim, Yi -Yeoun; Yang, Pengcheng; ...

    2016-01-06

    Manipulation of inorganic materials with organic macromolecules enables organisms to create biominerals such as bones and seashells, where occlusion of biomacromolecules within individual crystals generates superior mechanical properties. Current understanding of this process largely comes from studying the entrapment of micron-size particles in cooling melts. Here, by investigating micelle incorporation in calcite with atomic force microscopy and micromechanical simulations, we show that different mechanisms govern nanoscale occlusion. By simultaneously visualizing the micelles and propagating step edges, we demonstrate that the micelles experience significant compression during occlusion, which is accompanied by cavity formation. This generates local lattice strain, leading to enhancedmore » mechanical properties. Furthermore, these results give new insight into the formation of occlusions in natural and synthetic crystals, and will facilitate the synthesis of multifunctional nanocomposite crystals.« less

  19. Reconstruction-Based Digital Dental Occlusion of the Partially Edentulous Dentition.

    PubMed

    Zhang, Jian; Xia, James J; Li, Jianfu; Zhou, Xiaobo

    2017-01-01

    Partially edentulous dentition presents a challenging problem for the surgical planning of digital dental occlusion in the field of craniomaxillofacial surgery because of the incorrect maxillomandibular distance caused by missing teeth. We propose an innovative approach called Dental Reconstruction with Symmetrical Teeth (DRST) to achieve accurate dental occlusion for the partially edentulous cases. In this DRST approach, the rigid transformation between two symmetrical teeth existing on the left and right dental model is estimated through probabilistic point registration by matching the two shapes. With the estimated transformation, the partially edentulous space can be virtually filled with the teeth in its symmetrical position. Dental alignment is performed by digital dental occlusion reestablishment algorithm with the reconstructed complete dental model. Satisfactory reconstruction and occlusion results are demonstrated with the synthetic and real partially edentulous models.

  20. Reconstruction-based Digital Dental Occlusion of the Partially Edentulous Dentition

    PubMed Central

    Zhang, Jian; Xia, James J.; Li, Jianfu; Zhou, Xiaobo

    2016-01-01

    Partially edentulous dentition presents a challenging problem for the surgical planning of digital dental occlusion in the field of craniomaxillofacial surgery because of the incorrect maxillomandibular distance caused by missing teeth. We propose an innovative approach called Dental Reconstruction with Symmetrical Teeth (DRST) to achieve accurate dental occlusion for the partially edentulous cases. In this DRST approach, the rigid transformation between two symmetrical teeth existing on the left and right dental model is estimated through probabilistic point registration by matching the two shapes. With the estimated transformation, the partially edentulous space can be virtually filled with the teeth in its symmetrical position. Dental alignment is performed by digital dental occlusion reestablishment algorithm with the reconstructed complete dental model. Satisfactory reconstruction and occlusion results are demonstrated with the synthetic and real partially edentulous models. PMID:26584502

  1. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery.

    PubMed

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro

    2017-06-01

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. • Hepatic artery occlusion causes haemodynamic changes in hepatocellular carcinoma and liver. • Segmental occlusion decreased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Subsegmental occlusion increased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Hepatic artery occlusion decreased enhancement volume of hepatocellular carcinoma and liver. • Hepatic artery occlusion causes perfusion defects in hepatocellular carcinoma.

  2. Endovascular management of inferior vena cava filter thrombotic occlusion.

    PubMed

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  3. The mechanisms of intrarenal hemodynamic changes following acute arterial occlusion.

    DOT National Transportation Integrated Search

    1963-10-01

    The hemodynamic response of the kidney to acute arterial occlusion is poorly understood. The purpose of the present study was to determine intrarenal hemodynamic changes in intact and isolated kidneys following arterial occlusion. : The relative role...

  4. [A Project to Reduce the Occlusion Rate in Hemodialysis Arteriovenous Access].

    PubMed

    Huang, Jia-Ling; Jang, Jeng-Fong; Lee, Kun-Feng; Shie, Yu-Ting; Jin, Mei-Hua

    2015-06-01

    Vascular occlusions in patients frequently necessitate that duty nurses work overtime to manage related vascular problems. For patients, vascular occlusions require invasive treatments that are painful, take time to heal, and increase anxiety. Furthermore, vascular occlusions seriously influence the effectiveness of hemodialysis. This project worked to reduce the rates of occlusion from 18.6% to < 15% for hemodialysis arteriovenous grafts (AVGs) and from 5.2% to < 2.6% for arteriovenous fistulas (AVFs). This project was conducted between September 1st, 2012 and July 31th, 2013. Our approach used a retrospective study, literature review, meeting discussions, and data compilation. The four main problems identified as associated with occlusion were: (1) low blood pressure during hemodialysis; (2) successive fistula puncture sites were located too close to one another; (3) abnormal blood flow; and (4) poor moisture control. Our solutions included: 1) adjusting and creating forms; 2) adjusting related nursing procedures; and 3) organizing a related lecture for our department. The occlusion rates of AVG and AVF decreased from 18.6% to 7.4% and 5.2% to 0.9%, respectively. We significantly reduced AVG and AVF occlusion rates by using simple methods such as using a tourniquet ruler, designing big-print, illustrated patient instruction sheets on preventing low blood pressure, creating a simplified fistula puncture site series chart, creating a moisture control card, and scheduling follow-up visits for patients with abnormal blood flow at the OPD. This project provides a reference for other hemodialysis departments.

  5. Effect of occlusal trauma on healing of periapical pathoses: report of two cases.

    PubMed

    Harn, W M; Chen, M C; Chen, Y H; Liu, J W; Chung, C H

    2001-10-01

    To present two clinical cases and demonstrate that occlusal trauma may affect healing of periapical pathoses. Two teeth with periradicular disease did not respond successfully to conventional root canal treatment or endodontic surgery. Occlusal adjustment was finally performed on both cases. After occlusal adjustment, uncomplicated healing and periapical repair occurred in both cases. The findings in these two cases suggest that occlusal trauma may play a role in the healing of periapical pathoses. Occlusal trauma is positively correlated with changes in periodontal tissues. Although experiments in animals have shown that application of forces to teeth will not induce further periodontal destruction, we believe that some failures of root canal treatment may be due to the presence of occlusal trauma modulating the responses of inflamed periapical tissues or apical pathoses with persistent infection.

  6. A Study of Parallelism of the Occlusal Plane and Ala-Tragus Line

    PubMed Central

    Sadr, Katayoun; Sadr, Makan

    2009-01-01

    Background and aims Orientation of the occlusal plane is one of the most important clinical procedures in prostho-dontic rehabilitation of edentulous patients. The aim of this study was to define the best posterior reference point of ala-tragus line for orientation of occlusal plane for complete denture fabrication. Materials and methods Fifty-three dental students (27 females and 26 males) with complete natural dentition and Angel’s Class I occlusal relationship were selected. The subjects were photographed in natural head position while clenching on a Fox plane. After tracing the photographs, the angles between the following lines were measured: the occlusal plane (Fox plane) and the superior border of ala-tragus, the occlusal plane (Fox plane) and the middle of ala-tragus as well as the occlusal plane (Fox plane) and the inferior border of ala-tragus. Descriptive statistics, one sample t-test and independent t-test were used. P value less than 0.05 was considered significant. Results There was no parallelism between the occlusal plane and ala-tragus line with three different posterior ends and one sample t-test showed that the angles between them were significantly different from zero (p<0.05). However, the supe-rior border of ala-tragus line had the lowest mean angle, 1.80° (3.12) and was almost parallel to the occlusal plane. Conclusion The superior border of the tragus is suggested as the posterior reference for ala-tragus line. PMID:23230496

  7. Current status of percutaneous coronary intervention of chronic total occlusion

    PubMed Central

    Ge, Jun-bo

    2012-01-01

    This paper describes the current status of percutaneous coronary intervention (PCI) for totally occluded coronary arteries. Chronic total occlusion is associated with 10%–20% of all PCI procedures. Results show that opening an occluded vessel, especially one supplying a considerable area of myocardium, may be beneficial for a patient’s angina relief and heart function. We describe the devices used currently in re-canalization such as new wires, microcatheters (including Tonus and Cosair) and intravascular ultrasound guidance. Different techniques to improve the success rate and reduce complications are discussed in detail. PMID:22843178

  8. Effect of endovascular reperfusion in relation to site of arterial occlusion.

    PubMed

    Lemmens, Robin; Hamilton, Scott A; Liebeskind, David S; Tomsick, Tom A; Demchuk, Andrew M; Nogueira, Raul G; Marks, Michael P; Jahan, Reza; Gralla, Jan; Yoo, Albert J; Yeatts, Sharon D; Palesch, Yuko Y; Saver, Jeffrey L; Pereira, Vitor M; Broderick, Joseph P; Albers, Gregory W; Lansberg, Maarten G

    2016-02-23

    To assess whether the association between reperfusion and improved clinical outcomes after stroke differs depending on the site of the arterial occlusive lesion (AOL). We pooled data from Solitaire With the Intention for Thrombectomy (SWIFT), Solitaire FR Thrombectomy for Acute Revascularisation (STAR), Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution Study 2 (DEFUSE 2), and Interventional Management of Stroke Trial (IMS III) to compare the strength of the associations between reperfusion and clinical outcomes in patients with internal carotid artery (ICA), proximal middle cerebral artery (MCA) (M1), and distal MCA (M2/3/4) occlusions. Among 710 included patients, the site of the AOL was the ICA in 161, the proximal MCA in 389, and the distal MCA in 160 patients (M2 = 131, M3 = 23, and M4 = 6). Reperfusion was associated with an increase in the rate of good functional outcome (modified Rankin Scale [mRS] score 0-2) in patients with ICA (odds ratio [OR] 3.5, 95% confidence interval [CI] 1.7-7.2) and proximal MCA occlusions (OR 6.2, 95% CI 3.8-10.2), but not in patients with distal MCA occlusions (OR 1.4, 95% CI 0.8-2.6). Among patients with M2 occlusions, a subset of the distal MCA cohort, reperfusion was associated with excellent functional outcome (mRS 0-1; OR 2.2, 95% CI 1.0-4.7). The association between endovascular reperfusion and better clinical outcomes is more profound in patients with ICA and proximal MCA occlusions compared to patients with distal MCA occlusions. Because there are limited data from randomized controlled trials on the effect of endovascular therapy in patients with distal MCA occlusions, these results underscore the need for inclusion of this subgroup in future endovascular therapy trials. © 2016 American Academy of Neurology.

  9. Psychosocial distress of part-time occlusion in children with intermittent exotropia.

    PubMed

    Kim, Ungsoo Samuel; Park, Subin; Yoo, Hee Jeong; Hwang, Jeong-Min

    2013-01-01

    To evaluate the psychosocial distress of part-time occlusion therapy in intermittent exotropia. A total of 25 children (15 males and 10 females, aged 3 to 7 years, mean age 4.7 years) with intermittent exotropia were enrolled. Behavioral and psychosocial problems were assessed by the Korean Child Behavior Checklist (K-CBCL), which consists of eight categories of withdrawal, somatic problems, depression/anxiety, social problems, thought problems, attention problems, delinquent behavior, and aggressive behavior, and the Amblyopia Treatment Index (ATI). The ATI was designed to evaluate the three factors of compliance, adverse effect, and social stigma. The Parenting Stress Index (PSI) is a parent self-report designed to identify potentially dysfunctional parent-child systems. The K-CBCL was obtained before and after occlusion therapy, and the ATI and PSI were taken from parents only after occlusion therapy. We evaluated the change on the K-CBCL and the correlation between the K-CBCL and ATI. The attention problem assessed by the K-CBCL significantly decreased after occlusion therapy. On the ATI, the social stigma was relatively lower than compliance and adverse effect factors (Likert scale 2.64, 3.11, and 3.11, respectively). The somatic problem assessed by the K-CBCL and compliance on the ATI were significantly correlated (p = 0.014). There was no significant change in percentile scores of each subscale (parental dominant scale and child dominant scale) of the PSI. Total stress index before and after occlusion therapy was 97.16 ± 8.38 and 97.00 ± 8.16 respectively (p = 0.382). Occlusion therapy may influence the psychosocial impact on intermittent exotropia patients. Part-time occlusion significantly decreased the attention problem in children with intermittent strabismus. Children with a high somatic problem score on the KCBCL showed poor compliance to the part-time occlusion.

  10. Evidence Relating Subjective Contours and Interpretations Involving Occlusion.

    DTIC Science & Technology

    1981-06-01

    This article describes a patient with visual agnosia who is both unable to make the usual occlusion interpretations and is unable to see subjective...article describes a patient with visual agnosia who is both unable to make the usual occlusion interpretions and is unable to see subjective contours...Dr. Howard Gardner for providing access to the facilities at Boston Veterans Administration Hospital for examination of the agnosia patient J.R. Also

  11. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    PubMed

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  12. Head position affects the direction of occlusal force during tapping movement.

    PubMed

    Nakamura, K; Minami, I; Wada, J; Ikawa, Y; Wakabayashi, N

    2018-05-01

    Despite numerous reports describing the relationship between head position and mandibular movement in human subjects, the direction and magnitude of force at the occlusal contacts have not been investigated in relation to head position. The objective was to investigate the effect of head position on the direction of occlusal force while subjects performed a tapping movement. Twenty-three healthy adult subjects were asked to sit on a chair with their back upright and to perform 15 tapping movements in five different head positions: natural head position (control); forward; backward; and right and left rolled. The direction and magnitude of force were measured using a small triaxial force sensor. The Wilcoxon signed-rank test and Bonferroni test were used to compare head positions in each angle of the anteroposterior axis direction and the lateral axis direction with respect to the superior axis. The force element in the anteroposterior axis shifted to the forward direction in the head position pitched backward, compared with control, pitched forward and rolled left positions (P = .02, <.01 and <.01, respectively). The force direction in the lateral axis with the head position rolled to the right or left shifted to the left and right directions, respectively, compared with those in the other positions (P < .05). Results of this study suggest that the head should be maintained in a position in which a stable tapping movement can be performed in a relaxed position without anteroposterior and lateral loading. © 2018 John Wiley & Sons Ltd.

  13. A cephalometric study to determine the plane of occlusion in completely edentulous patients.

    PubMed

    Hindocha, Amit D; Vartak, Vikas N; Bhandari, Aruna J; Dudani, Mohit T

    2013-01-01

    Determination of the plane of occlusion in completely edentulous patients with the help of the ala-tragus line (Camper's plane) may be questioned. An attempt to devise an alternative method to determine the orientation of the plane of occlusion was made. Cephalometric analysis was used to identify whether a correlation exists between the plane of occlusion of dentulous Indian individuals and other stable cranial landmarks. A negative correlation was found to exist between the occlusal Plane-FH plane angle and the porion-nasion-anterior nasal spine (PoNANS) angle. From the derived mathematical correlation, it was concluded that the angulation of the occlusal plane in completely edentulous subjects may be determined by taking a cephalogram at the diagnostic stage. Further, the clinical applicability of the derived mathematical formula (while determining the plane of occlusion) was tested on completely edentulous patients.

  14. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    PubMed Central

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  15. Interdisciplinary treatment of bruxism with an occlusal splint and cognitive behavioral therapy.

    PubMed

    Trindade, Marilene; Orestes-Cardoso, Silvana; de Siqueira, Teresa Cristina

    2015-01-01

    The etiology of bruxism is associated with exogenous factors, such as occlusal interference, stress, and anxiety, as well as endogenous factors involving neurotransmitters of the basal ganglia. Due to the multifactorial etiology of bruxism, interdisciplinary treatment involving professionals from different healthcare fields has been proposed. The aim of the present study was to compare 2 groups of patients with bruxism (11 in each group) treated with either an occlusal splint combined with cognitive behavioral therapy or an occlusal splint alone. Surface electromyography of the masseter and anterior temporal muscles at rest was performed before and after treatment. The mean amplitude of activity of all muscles was lower after treatment, except for the right anterior temporal muscle in the group treated with an occlusal splint alone. Mean amplitudes were greater in the anterior temporal muscles than in the masseter muscles. Significantly greater improvement was found in the group exposed to cognitive behavioral therapy (P < 0.05; analysis of variance and Student t tests). Therefore, the combination of occlusal splint and psychological therapy was more effective at achieving muscle relaxation than occlusal splint use alone.

  16. Occlusive retinal vasculitis in a patient with West Nile virus.

    PubMed

    Teitelbaum, Bruce A; Newman, Tricia L; Tresley, David J

    2007-11-01

    West Nile virus (WNV) was first identified in the United States in 1999. In addition to a spectrum of systemic manifestations, several ocular conditions secondary to the virus have been reported, including chorioretinitis, uveitis and optic neuritis. Age and diabetes mellitus (DM) have been reported to be associated risk factors for the more severe forms of the systemic disease. Only seven cases of occlusive retinal vasculitis have been reported in patients with WNV infection. A 60-year-old Asian male presented with complaints of decreased vision in his left eye. He had been hospitalised approximately seven weeks earlier with meningo-encephalitis secondary to presumed WNV infection, at which time he was also diagnosed with DM. The visual loss coincided with the manifestation of systemic WNV infection. Old peripheral chorioretinal lesions without active inflammation in both eyes were consistent with WNV infection. In addition, retinal haemorrhage and cotton wool spots were noted in the posterior pole of both eyes with severe macular ischaemia in the left eye. Occlusive retinal vasculitis is an uncommon ocular manifestation of WNV, which should be suspected in patients with meningitis or encephalitis who reside in endemic areas with ocular findings of the disease.

  17. Reduction of deviation angle during occlusion therapy: in partially accommodative esotropia with moderate amblyopia.

    PubMed

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa; Kwon, Jung Yoon

    2007-09-01

    To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Mean deviation angle with glasses at the start of occlusion treatment was 19.45+/-5.97 PD and decreased to 12.14+/-12.96 PD at 2 years after occlusion therapy (p<0.01). After occlusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia.

  18. Reduction of Deviation Angle During Occlusion Therapy: In Partially Accommodative Esotropia with Moderate Amblyopia

    PubMed Central

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa

    2007-01-01

    Purpose To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Methods Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Results Mean deviation angle with glasses at the start of occlusion treatment was 19.45±5.97 PD and decreased to 12.14±12.96 PD at 2 years after occlusion therapy (p<0.01). After occlusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). Conclusions There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia. PMID:17804922

  19. Transcatheter vessel occlusion: angiographic results versus clinical success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, L.; Greenfield, A.J.; Waltman, A.C.

    1983-04-01

    A review was made of 219 transcatheter vessel occlusion procedures performed over a ten-year period for control of hemorrhage, tumor palliation, or blood supply redistribution prior to intra-arterial chemotherapy. Complete angiographic success was obtained in 85% of the procedures, with partial success in 8%; complete clinical success was achieved in 53% of patients, with partial success in 23%. the most satisfactory clinical results were obtained with hemorrhagic gastritis and pelvic trauma. Embolizations for duodenal ulcer hemorrhage and transhepatic variceal occlusion were the least clinically successful, although isobutyl-cyanoacrylate appeared to be a significant improvement in angiographic therapy for duodenal ulcer. Themore » overall complication rate was 13%, with one third of the complications clinically silent. These results indicate that transcatheter vessel occlusion is a relatively safe and effective method for control of hemorrhage or tumor infarction.« less

  20. Review of Allergic and Photoallergic Contact Dermatitis from an Ingredient in a Medicament Vehicle Consisting of a Compress, Poultice, Plaster, and Tape

    PubMed Central

    Oiso, Naoki; Kawada, Akira

    2011-01-01

    The topical application of a medicament vehicle consisting of a compress, poultice, plaster, and tape containing a nonsteroidal anti-inflammatory drug or methyl salicylate is prevalent in Japan. The method is effective for conveying ingredients to the muscles via the skin for the relief of muscular pain. However, an ingredient in the occlusive vehicle can cause allergic and photoallergic contact dermatitis. We summarize cases reported over the past decade and discuss the current strategy for diminishing the risk of allergic and photoallergic contact dermatitis. PMID:21603165

  1. Implications of Natural Occlusion of Ventilated Racks on Ammonia and Sanitation Practices

    PubMed Central

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-01-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague–Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded. PMID:24602544

  2. Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.

    PubMed

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-03-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague-Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded.

  3. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, Marlies, E-mail: marlies.wagner@kgu.de; Kyriakou, Yiannis, E-mail: yiannis.kyriakou@siemens.com; Mesnil de Rochemont, Richard du, E-mail: mesnil@em.uni-frankfurt.de

    2013-08-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebralmore » PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.« less

  4. Two-photon imaging during prolonged middle cerebral artery occlusion in mice reveals recovery of dendritic structure after reperfusion.

    PubMed

    Li, Ping; Murphy, Timothy H

    2008-11-12

    Filament occlusion of the middle cerebral artery (MCA) is a well accepted animal model of focal ischemia. Advantages of the model are relatively long occlusion times and a large penumbra region that simulates aspects of human stroke. Here, we use two-photon and confocal microscopy in combination with regional measurement of blood flow using laser speckle to assess the spatial relationship between the borders of the MCA ischemic territory and loss of dendrite structure, as well as the effect of reperfusion on dendritic damage in adult YFP (yellow fluorescent protein) and GFP (green fluorescent protein) C57BL/6 transgenic mice with fluorescent (predominantly layer 5) neurons. By examining the spatial extent of dendritic damage, we determined that 60 min of MCA occlusion produced a core with severe structural damage that did not recover after reperfusion (begins approximately 3.8 mm lateral to midline), a reversibly damaged area up to 0.6 mm medial to the core that recovered after reperfusion (penumbra), and a relatively structurally intact area ( approximately 1 mm wide; medial penumbra) with hypoperfusion. Loss of structure was preceded by a single ischemic depolarization 122.1 +/- 10.2 s after occlusion onset. Reperfusion of animals after 60 min of ischemia was not associated with exacerbation of damage (reperfusion injury) and resulted in a significant restoration of blebbed dendritic structure, but only within approximately 0.6 mm lateral of the dendritic damage structural border. In summary, we find that recovery of dendritic structure can occur after reperfusion after even 60 min of ischemia, but is likely restricted to a relatively small penumbra region with partial blood flow or oxygenation.

  5. Physical properties of root cementum: part 24. Root resorption of the first premolars after 4 weeks of occlusal trauma.

    PubMed

    Cakmak, Fethiye; Turk, Tamer; Karadeniz, Ersan Ilsay; Elekdag-Turk, Selma; Darendeliler, M Ali

    2014-05-01

    In orthodontics, adding restorative materials on occlusal or lingual surfaces is a common method to create a mini-biteplane to increase patients' vertical dimension temporarily to facilitate several treatment procedures. However, this method transmits excessive occlusal forces through the periodontal ligament and causes trauma. In this prospective randomized clinical trial, we measured and compared quantitatively the volumes of root resorption after 4 weeks of occlusal trauma. Forty-eight maxillary and mandibular first premolars of 12 patients (6 girls, 6 boys) comprised the sample for this study. One side of each patient was randomly selected as the control. On the contralateral side, a light-cured glass ionomer cement (Transbond Plus Light Cure Band Adhesive; 3M Unitek, Monrovia, Calif) was bonded onto the occlusal surface of the mandibular first premolar so that the cement was in contact with the maxillary first premolar. After 4 weeks, both first premolars were extracted. Each sample was imaged using a microcomputed tomography system (1172; SkyScan, Aartselaar, Belgium) and analyzed with specially designed software for volumetric measurements of resorption craters. Furthermore, pain was evaluated with a visual analog scale for 7 days. There were significant differences in the amounts of root resorption between the control and the experimentally traumatized teeth. No significant difference among the buccal, lingual, mesial, and distal surfaces was found in either jaw. Furthermore, no significant difference existed in the amount of root resorption among the cervical, middle, and apical thirds of both jaws. There was no correlation between age, sex, volume of the root resorption craters, and pain. Restorative buildups, used to increase the vertical dimension by 2 mm for 4 weeks, caused root resorption along the sides of the teeth during the active bite-increase period. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights

  6. Visual Acuity Improvement in Continuous vs Divided Occlusion in Anisometropic Amblyopia

    PubMed Central

    Irfani, Irawati; Feriyanto, Feri; Oktarima, Primawita; Kartasasmita, Arief

    2018-01-01

    Purpose: To compare visual acuity improvement between continuous and split part-time occlusion for the treatment of moderate and severe anisometropic amblyopia. Methods: Randomised clinical trials in 6 – 13 y.o children with moderate and severe anisometropic amblyopia. Each patient was consecutively selected with continuous or split part-time occlusion. Best corrected visual acuity’s improvement was followed up to six weeks and statistical data were analyzed using chi square and unpaired t-test. Results: Best corrected visual acuity’s improvement was comparable between continuous and split part-time occlusion (0.20±0.27 vs 0.21±0.25; p = 0.79). Conclusion: Split part-time occlusion may be considered as an alternative treatment for moderate and severe anisometropic amblyopia treatment. PMID:29515681

  7. Occlus-o-Guide® versus Andresen activator appliance: neuromuscular evaluation.

    PubMed

    Farronato, Giampietro; Giannini, Lucia; Galbiati, Guido; Grillo, Elena; Maspero, Cinzia

    2013-05-20

    The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-Guide® and Andresen activator appliances. Eighty-two patients (35 males and 47 females) aged between 8 and 12 years (mean age, 10.5±0.8 years) participated in the study. Fifty patients underwent treatment with an Occlus-o-Guide® and 32 patients with an Andresen activator. All patients underwent EMG examination using a Freely EMG (De Gotzen, Legnano, Italy) and surface bipolar electrodes when the appliances were worn for the first time (T0), and after 6 months (T1) and after 12 months (T2) of appliance use. Statistical analysis showed that both at T0 and T2, the percent overlapping coefficient (POC) of the anterior temporalis muscles was not statistically different between the appliance groups. At T0, the POC of the masseter muscles was significantly lower for the Andresen appliance as compared to the Occlus-o-Guide® (p=0.02), while at T2 this significance was lost. At insertion of an appliance, all patients show neuromuscular balance that does not correspond to orthognathic occlusion. Both appliances work by creating muscular imbalance. With the appliances in situ, EMG responses were generally analogous for the Occlus-o-Guide® and the Andresen activator; however, the imbalance was greater and the recovery of the orthological muscular balance was slower in patients under treatment with the Andresen activator as compared to those with the Occlus-o-Guide®.

  8. Effect of electrode contact area on the information content of the recorded electrogastrograms: An analysis based on Rényi entropy and Teager-Kaiser Energy

    NASA Astrophysics Data System (ADS)

    Alagumariappan, Paramasivam; Krishnamurthy, Kamalanand; Kandiah, Sundravadivelu; Ponnuswamy, Mannar Jawahar

    2017-06-01

    Electrogastrograms (EGG) are electrical signals originating from the digestive system, which are closely correlated with its mechanical activity. Electrogastrography is an efficient non-invasive method for examining the physiological and pathological states of the human digestive system. There are several factors such as fat conductivity, abdominal thickness, change in electrode surface area etc, which affects the quality of the recorded EGG signals. In this work, the effect of variations in the contact area of surface electrodes on the information content of the measured electrogastrograms is analyzed using Rényi entropy and Teager-Kaiser Energy (TKE). Two different circular cutaneous electrodes with approximate contact areas of 201.14 mm2 and 283.64 mm2, have been adopted and EGG signals were acquired using the standard three electrode protocol. Further, the information content of the measured EGG signals were analyzed using the computed values of entropy and energy. Results demonstrate that the information content of the measured EGG signals increases by 6.72% for an increase in the contact area of the surface electrode by 29.09%. Further, it was observed that the average energy increases with increase in the contact surface area. This work appears to be of high clinical significance since the accurate measurement of EGG signals without loss in its information content, is highly useful for the design of diagnostic assistance tools for automated diagnosis and mass screening of digestive disorders.

  9. Recent advances in managing vascular occlusions in the cardiac catheterization laboratory

    PubMed Central

    Qureshi, Athar M.; Mullins, Charles E.; Latson, Larry A.

    2018-01-01

    Vascular occlusions continue to be a significant cause of morbidity and mortality. The management of vascular occlusions in patients is complex, requiring specialized expertise in the cardiac catheterization laboratory and from other disciplines. Knowledge of currently available tools at the operator’s disposal is important to optimize the success of these procedures. In this review, we discuss some of the recent advances in recanalization procedures of vascular occlusions and thrombotic lesions in the cardiac catheterization laboratory. PMID:29770200

  10. Management of Retinal Vein Occlusion, Who Is Responsible?

    PubMed

    Aghamirsalim, Mohamadreza; Sorbi, Reza; Naderian, Mohammadreza; Cugati, Sudha; Shahsuvaryan, Marianne Levon; Ghazizadeh Hashemi, Maryam

    2016-11-01

    Retinal vein occlusion (RVO) is a common retinal vascular occlusive disorder and is associated with a variety of systemic risk factors. The aim of this study was to investigate whether the underlying diseases were evaluated and managed appropriately by ophthalmologists. We performed a study of 1344 patients with retinal vein occlusion (RVO). Patients were evaluated with a questionnaire including ten closed questions to determine whether ophthalmologists evaluated and informed their patients about the underlying systemic diseases. None of the patients' homocysteine levels were measured. Only a small percentage of the patients were asked about the history of thrombotic diseases or family history of thrombotic diseases. We believe that most ophthalmologists are still not entirely convinced of their responsibility of managing the underlying predisposing factors of RVO. Ophthalmologists should either manage or engage other healthcare providers in the management of RVO to guarantee the patient the best care.

  11. Dental caries, contact with dental services and deprivation in young children: their relationship at a small area level.

    PubMed

    Tickle, M; Moulding, G; Milsom, K; Blinkhorn, A

    2000-10-14

    To measure the relationship between tooth decay, contact with dental services and deprivation at electoral ward level. The study was carried out in 1998 in Ellesmere Port in the North West of England. All children younger than six years resident in Ellesmere Port registered with GDS services and those using CDS services were matched against the HA population register to identify unregistered children. Rates for children aged 3-5 years 'in contact' with primary dental care services, whether CDS or GDS, were calculated at ward level. One calibrated examiner examined all 5-year-old children in Ellesmere Port and dmft scores were calculated at ward level. Ward deprivation was measured using the Jarman score. Bivariate linear regressions at ward level were performed in turn between: dmft and Jarman score; rates for 3-5-year-olds in contact with dental services and Jarman score; and dmft and rates for 3-5-year-olds in contact with dental services. A significant linear relationship was observed between dmft and Jarman score (P=0.02, R2 = 0.43). Significant inverse relationships were found between rates for 3-5-year-olds in contact with dental services and Jarman score (P=0.001, R2 = 0.67), and also between dmft and rates for 3-5-year-olds in contact with dental services (P=0.002, R2 = 0.65). A strong inverse relationship was found between dental caries and contact with primary dental care services at electoral ward level. This relationship needs to be explored over a wider geographical area to establish if it is consistent and independent of deprivation.

  12. Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants.

    PubMed

    Willing, Ryan; King, Graham J W; Johnson, James A

    2015-11-26

    Erosion of articular cartilage is a concern following distal humeral hemiarthroplasty, because native cartilage surfaces are placed in contact with stiff metallic implant components, which causes decreases in contact area and increases in contact stresses. Recently, reverse engineered implants have been proposed which are intended to promote more natural contact mechanics by reproducing the native bone or cartilage shape. In this study, finite element modeling is used in order to calculate changes in cartilage contact areas and stresses following distal humeral hemiarthroplasty with commercially available and reverse engineered implant designs. At the ulna, decreases in contact area were -34±3% (p=0.002), -27±1% (p<0.001) and -14±2% (p=0.008) using commercially available, bone reverse engineered and cartilage reverse engineered designs, respectively. Peak contact stresses increased by 461±57% (p=0.008), 387±127% (p=0.229) and 165±16% (p=0.003). At the radius, decreases in contact area were -21±3% (p=0.013), -13±2% (p<0.006) and -6±1% (p=0.020), and peak contact stresses increased by 75±52% (p>0.999), 241±32% (p=0.010) and 61±10% (p=0.021). Between the three different implant designs, the cartilage reverse engineered design yielded the largest contact areas and lowest contact stresses, but was still unable to reproduce the contact mechanics of the native joint. These findings align with a growing body of evidence indicating that although reverse engineered hemiarthroplasty implants can provide small improvements in contact mechanics when compared with commercially available designs, further optimization of shape and material properties is required in order reproduce native joint contact mechanics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. The dental literature on occlusion and myogenous orofacial pain: application of critical thinking.

    PubMed

    Solow, Roger Alan

    2016-09-01

    To enhance the reader's critical thinking when reading the dental literature on the relationship of occlusion and myogenous orofacial pain (MOP). Representative journal articles and systematic reviews from the dental literature confirming and denying a relationship of occlusion to MOP were analyzed and reviewed. Studies using computerized occlusal analysis (COA) consistently find a relationship of the occlusion to MOP. Studies that do not confirm this relationship have problems with invalid primary source conclusions, unstated assumptions, bias, and errors in logic that disqualify their conclusion. This review explains four categories of problems with the dental literature that denies occlusion has a relationship with MOP. When the reader understands these examples of flaws in this literature, they can apply this critical thinking to future studies. Correct interpretation of the literature on occlusion and MOP requires a foundation of basic and clinical scientific knowledge as well as an understanding of the details of the primary source articles.

  14. Ambient occlusion effects for combined volumes and tubular geometry.

    PubMed

    Schott, Mathias; Martin, Tobias; Grosset, A V Pascal; Smith, Sean T; Hansen, Charles D

    2013-06-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  15. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    PubMed Central

    Schott, Mathias; Martin, Tobias; Grosset, A.V. Pascal; Smith, Sean T.; Hansen, Charles D.

    2013-01-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed. PMID:23559506

  16. Comparison of vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification systems.

    PubMed

    Han, Young Keun; Miller, Kevin M

    2009-08-01

    To compare vacuum rise time, vacuum limit accuracy, and occlusion break surge of 3 new phacoemulsification machines. Jules Stein Eye Institute and Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. The vacuum rise time under normal and enhanced aspiration modes, vacuum limit accuracy, and occlusion break surge of the Infiniti Vision System, Stellaris Vision Enhancement System, and WhiteStar Signature Phacoemulsification System were tested. Vacuum rise time and limit accuracy were measured at limit settings of 400 mm Hg and 600 mm Hg. Surge area was recorded at vacuum limit settings of 200 mm Hg, 300 mm Hg, 400 mm Hg, and 500 mm Hg. The Infiniti had the fastest vacuum rise times under normal and enhanced aspiration modes. At 4 seconds, the vacuum limit accuracy was greatest with the Infiniti at the 400 mm Hg limit and the Signature at the 600 mm Hg limit. The Stellaris did not reach either vacuum target. The Infiniti performed better than the other 2 machines during testing of occlusion break surge at all vacuum limit settings above 200 mm Hg. Under controlled laboratory test conditions, the Infiniti had the fastest vacuum rise time, greatest vacuum limit accuracy at 400 mm Hg, and least occlusion break surge. These results can be explained by the lower compliance of the Infiniti system.

  17. Occlusion assessment of intracranial aneurysms treated with the WEB device.

    PubMed

    Caroff, Jildaz; Mihalea, Cristian; Tuilier, Titien; Barreau, Xavier; Cognard, Christophe; Desal, Hubert; Pierot, Laurent; Arnoux, Armelle; Moret, Jacques; Spelle, Laurent

    2016-09-01

    The Woven EndoBridge (WEB) system is an innovative device under evaluation for its capacity to treat wide-neck bifurcation intracranial aneurysms. The purpose of this study is to evaluate the use of the different occlusion scales available in clinical practice. Seven WEB-experienced neurointerventionalists were provided with 30 angiographic follow-up data sets and asked to grade each evaluation point according to the Bicêtre Occlusion Scale Score (BOSS), firstly based on DSA images only then using additional C-Arm VasoCT analysis. This BOSS evaluation was then converted into the WEB Occlusion Scale (WOS) and into a dichotomized scale (complete occlusion or not). To estimate the inter-rater agreement among the seven raters, an overall kappa coefficient [1] and its standard error (SE) were computed. Using the five-grade BOSS, raters showed "moderate" agreement (kappa = 0.56). Using the three-grade WOS, agreement appeared slightly better (kappa = 0.59). Strongest inter-rater agreement was observed with a dichotomized version of the scale (complete occlusion or not), which enabled an "almost perfect" agreement (kappa = 0.88). VasoCT consistently enhanced the agreement particularly with regards depicting intra-WEB residual filling. The WOS is a consistent means to angiographically evaluate the WEB device efficiency. But the five-grade BOSS scale allows to identify aneurysm subgroups with differing risks of recurrence and/or rehemorrhage, which needs to be separated especially at the initial phase of evaluation of this innovative device. The additional use of VasoCT allows better inter-rater agreement in evaluating occlusion and specially in depicting intra-WEB persistent filling.

  18. Occlus-o-Guide® versus Andresen activator appliance: neuromuscular evaluation

    PubMed Central

    2013-01-01

    Background The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-Guide® and Andresen activator appliances. Methods Eighty-two patients (35 males and 47 females) aged between 8 and 12 years (mean age, 10.5 ± 0.8 years) participated in the study. Fifty patients underwent treatment with an Occlus-o-Guide® and 32 patients with an Andresen activator. All patients underwent EMG examination using a Freely EMG (De Gotzen, Legnano, Italy) and surface bipolar electrodes when the appliances were worn for the first time (T0), and after 6 months (T1) and after 12 months (T2) of appliance use. Results Statistical analysis showed that both at T0 and T2, the percent overlapping coefficient (POC) of the anterior temporalis muscles was not statistically different between the appliance groups. At T0, the POC of the masseter muscles was significantly lower for the Andresen appliance as compared to the Occlus-o-Guide® (p = 0.02), while at T2 this significance was lost. Conclusions At insertion of an appliance, all patients show neuromuscular balance that does not correspond to orthognathic occlusion. Both appliances work by creating muscular imbalance. With the appliances in situ, EMG responses were generally analogous for the Occlus-o-Guide® and the Andresen activator; however, the imbalance was greater and the recovery of the orthological muscular balance was slower in patients under treatment with the Andresen activator as compared to those with the Occlus-o-Guide®. PMID:24325935

  19. Farmer Contacts with District Agriculturists in Three Areas in British Columbia.

    ERIC Educational Resources Information Center

    Akinbode, Isaac A.; Dorling, M. J.

    This study analyzed data gathered in a Canada Land Inventory project in British Columbia; the purpose was to measure the degree of communication between farmers and the agricultural extension service by analyzing the nature and extent of contacts, and the relationship of the contacts to socioeconomic characteristics. The farmers tended to be an…

  20. Lower body positive pressure application with an antigravity suit in acute carotid occlusion.

    PubMed

    Berthet, Karine; Lukaszewicz, Anne Claire; Bousser, Marie-Germaine; Payen, Didier

    2010-04-01

    The challenge in acute stroke is still to reperfuse as early as possible the ischemic territory. Since fibrinolytic therapies have a limited window with potential risk of bleeding, having a nonpharmacologic mean to recruit vessels in area surrounding necrosis might be useful. We propose here to use antigravity suit inflated at "venous" pressure levels to shift blood towards thoracic and brain territories. We report two cases of spectacular clinical recovery after acute carotid occlusion.

  1. Hardness and posting of foot orthoses modify plantar contact area, plantar pressure, and perceived comfort when cycling.

    PubMed

    Bousie, Jaquelin A; Blanch, Peter; McPoil, Thomas G; Vicenzino, Bill

    2018-07-01

    To evaluate the effects of hardness and posting of orthoses on plantar profile and perceived comfort and support during cycling. A repeated measures study with randomised order of orthoses, hardness, and posting conditions. Twenty-three cyclists cycled at a cadence of 90rpm and a perceived exertion rating of twelve. Contoured soft and hard orthoses with or without a medial forefoot or lateral forefoot post were evaluated. Plantar contact area, mean pressure and peak pressure were measured for nine plantar regions using the pedar ® -X system and represented as a percentage of the total (CA%, MP%, and PP% respectively). Perceived comfort and support was rated on a visual analogue scale. The softer orthosis significantly increased CA% (p=0.014) across the midfoot and heel with a decrease in the toe region and forefoot. MP% (p=0.034) and PP% (p=0.012) were significantly increased at the mid and lateral forefoot with reductions in MP% at the midfoot and in PP% at the hallux and toes. Forefoot posting significantly increased CA% (p=0.018) at the toes and forefoot and decreased it at the heel. PP% was significantly altered (p=0.013) based on posting position. Lateral forefoot posting significantly decreased heel comfort (p=0.036). When cycling, a soft, contoured orthosis increased contact across the midfoot and heel, modulating forefoot and midfoot plantar pressures but not altering comfort or support. Forefoot postings significantly modified contact areas and plantar pressures and reduced comfort at the heel. Copyright © 2017. Published by Elsevier Ltd.

  2. Reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old.

    PubMed

    Megbelayin, E; Ekpenyong, S M; Azunobi, J; Ejiro, G

    2014-03-01

    To report a reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old. Case report. Eye clinic of a University Teaching Hospital in a metropolitan city. an index patient. Occlusion therapy. Post occlusion visual acuity. Presenting unaided visual acuity of right eye: 6/6, left eye: 4/60. Refraction result was: right eye: -0.50DS (6/6), left eye: -3.50DS (6/18). Following day time occlusion therapy of at least 6 hours for about 4 weeks, subjective refraction was: right eye: -0.5DS (6/5), left eye: -3.50DS (6/6(+3)). The remarkable improvement in vision at age 25 years of a patient with myopic anisometropic amblyopia shows that occlusion therapy might still be useful long after amblyogenic period.

  3. Veno-occlusive disease and primary hepatic vein thrombosis in Israeli Arabs.

    PubMed

    Ghanem, J; Hershko, C

    1981-05-01

    In a survey of nine major Israeli hospitals, 29 patients diagnosed between 1955 and 1975 as suffering from hepatic vein thrombosis were identified. Fifteen of the patients were Jews and 14 were Arabs. In contrast to the Jewish patients, all of whom were adults, the majority of the Arab patients were children below 10 years of age. Primary hepatic vein occlusion was 2.4 times more common among Arab than among Jewish patients. Of the 11 Arab patients with primary hepatic vein occlusion, three had histological changes typical of veno-occlusive disease; whereas in five others, thrombotic occlusion of large hepatic veins or of the vena cava was documented. Although no plant alkaloids could be directly implicated in any of the Arab patients, circumstantial evidence strongly supports such an etiology. All of our Arab patients originated from small agricultural communities where ancient methods of winnowing, which expose the home-ground wheat to a high risk of contamination by grains containing pyrrolizidine alkaloids, are still in use. This report confirms the world-wide distribution of veno-occlusive disease, and under-lines the need for a systematic search for possible sources of poisoning by pyrrolizidine alkaloids.

  4. The effect of occlusion therapy on motion perception deficits in amblyopia.

    PubMed

    Giaschi, Deborah; Chapman, Christine; Meier, Kimberly; Narasimhan, Sathyasri; Regan, David

    2015-09-01

    There is growing evidence for deficits in motion perception in amblyopia, but these are rarely assessed clinically. In this prospective study we examined the effect of occlusion therapy on motion-defined form perception and multiple-object tracking. Participants included children (3-10years old) with unilateral anisometropic and/or strabismic amblyopia who were currently undergoing occlusion therapy and age-matched control children with normal vision. At the start of the study, deficits in motion-defined form perception were present in at least one eye in 69% of the children with amblyopia. These deficits were still present at the end of the study in 55% of the amblyopia group. For multiple-object tracking, deficits were present initially in 64% and finally in 55% of the children with amblyopia, even after completion of occlusion therapy. Many of these deficits persisted in spite of an improvement in amblyopic eye visual acuity in response to occlusion therapy. The prevalence of motion perception deficits in amblyopia as well as their resistance to occlusion therapy, support the need for new approaches to amblyopia treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Traction of elastohydrodynamic contacts with thermal shearing flow

    NASA Technical Reports Server (NTRS)

    Jakobsen, J.; Winer, W. O.

    1974-01-01

    The formulation and solution for the shear stress and temperature in heavily loaded sliding elastohydrodynamic contacts is presented. The solutions are presented in dimensionless design charts. Integration over the contact area will yield the traction. Accuracy is expected to be very good over the nearly flat part of the contact area where the majority of the sliding traction is generated. The procedure presented is not appropriate for thick film lubrication, for the inlet region, or for the rolling friction of elastohydrodynamic contacts.

  6. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    PubMed

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  7. Guide wire extension for shape memory polymer occlusion removal devices

    DOEpatents

    Maitland, Duncan J [Pleasant Hill, CA; Small, IV, Ward; Hartman, Jonathan [Sacramento, CA

    2009-11-03

    A flexible extension for a shape memory polymer occlusion removal device. A shape memory polymer instrument is transported through a vessel via a catheter. A flexible elongated unit is operatively connected to the distal end of the shape memory polymer instrument to enhance maneuverability through tortuous paths en route to the occlusion.

  8. Correlation-based perfusion mapping using time-resolved MR angiography: A feasibility study for patients with suspicions of steno-occlusive craniocervical arteries.

    PubMed

    Nam, Yoonho; Jang, Jinhee; Park, Sonya Youngju; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-Soo

    2018-05-22

    To explore the feasibility of using correlation-based time-delay (CTD) maps produced from time-resolved MR angiography (TRMRA) to diagnose perfusion abnormalities in patients suspected to have steno-occlusive lesions in the craniocervical arteries. Twenty-seven patients who were suspected to have steno-occlusive lesions in the craniocervical arteries underwent both TRMRA and brain single-photon emission computed tomography (SPECT). TRMRA was performed on the supra-aortic area after intravenous injection of a 0.03 mmol/kg gadolinium-based contrast agent. Time-to-peak (TTP) maps and CTD maps of the brain were automatically generated from TRMRA data, and their quality was assessed. Detection of perfusion abnormalities was compared between CTD maps and the time-series maximal intensity projection (MIP) images from TRMRA and TTP maps. Correlation coefficients between quantitative changes in SPECT and parametric maps for the abnormal perfusion areas were calculated. The CTD maps were of significantly superior quality than TTP maps (p < 0.01). For perfusion abnormality detection, CTD maps (kappa 0.84, 95% confidence interval [CI] 0.67-1.00) showed better agreement with SPECT than TTP maps (0.66, 0.46-0.85). For perfusion deficit detection, CTD maps showed higher accuracy (85.2%, 95% CI 66.3-95.8) than MIP images (66.7%, 46-83.5), with marginal significance (p = 0.07). In abnormal perfusion areas, correlation coefficients between SPECT and CTD (r = 0.74, 95% CI 0.34-0.91) were higher than those between SPECT and TTP (r = 0.66, 0.20-0.88). CTD maps generated from TRMRA were of high quality and offered good diagnostic performance for detecting perfusion abnormalities associated with steno-occlusive arterial lesions in the craniocervical area. • Generation of perfusion parametric maps from time-resolved MR angiography is clinically useful. • Correlation-based delay maps can be used to detect perfusion abnormalities associated with steno-occlusive craniocervical arteries

  9. Computerized classification of proximal occlusion in the left anterior descending coronary artery.

    PubMed

    Gregg, Richard E; Nikus, Kjell C; Zhou, Sophia H; Startt Selvester, Ronald H; Barbara, Victoria

    2010-01-01

    Proximal occlusion within the left anterior descending (LAD) coronary artery in patients with acute myocardial infarction leads to higher mortality than does nonproximal occlusion. We evaluated an automated program to detect proximal LAD occlusion. All patients with suspected acute coronary syndrome (n = 7,710) presenting consecutively to the emergency department of a local hospital with a coronary angiogram–confirmed flow-limiting lesion and notation of occlusion site were included in the study (n = 711). Electrocardiograms (ECGs) that met ST-segment elevation myocardial infarction (STEMI) criteria were included in the training set (n = 183). Paired angiographic location of proximal LAD and ECGs with ST elevation in the anterolateral region were used for the computer program development (n = 36). The test set was based on ECG criteria for anterolateral STEMI only without angiographic reports (n = 162). Tested against 2 expert cardiologists' agreed reading of proximal LAD occlusion, the algorithm has a sensitivity of 95% and a specificity of 82%. The algorithm is designed to have high sensitivity rather than high specificity for the purpose of not missing any proximal LAD in the STEMI population. Our preliminary evaluation suggests that the algorithm can detect proximal LAD occlusion as an additional interpretation to STEMI detection with similar accuracy as cardiologist readers.

  10. Retinal vein occlusion: current treatment.

    PubMed

    Lattanzio, Rosangela; Torres Gimeno, Ana; Battaglia Parodi, Maurizio; Bandello, Francesco

    2011-01-01

    Retinal vein occlusion (RVO) is a pathology noted for more than 150 years. Although a lot has been written on the matter, it is still a frequent condition with multifactorial etiopathogenesis with many unclear aspects. The RVO pathogenesis has varied systemic and local implications that make it difficult to elaborate treatment guidelines. The management of the patient with RVO is very complex and a multidisciplinary approach is required in order to identify and correct the associated risk factors. Laser therapy remains the gold standard in RVO, but only modest functional improvement has been shown in branch retinal occlusion forms. Multicenter studies of intravitreal drugs present them as an option to combine with laser. Anti-vascular endothelial growth factor, corticosteroids and sustained-release implants are the future weapons to stop disease progression and get a better visual outcome. Consequently, it is useful to clarify some aspects of the pathology that allow a better patient management. Copyright © 2010 S. Karger AG, Basel.

  11. Ferromagnetic tunnel contacts to graphene: Contact resistance and spin signal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cubukcu, M.; Laczkowski, P.; Vergnaud, C.

    2015-02-28

    We report spin transport in CVD graphene-based lateral spin valves using different magnetic contacts. We compared the spin signal amplitude measured on devices where the cobalt layer is directly in contact with the graphene to the one obtained using tunnel contacts. Although a sizeable spin signal (up to ∼2 Ω) is obtained with direct contacts, the signal is strongly enhanced (∼400 Ω) by inserting a tunnel barrier. In addition, we studied the resistance-area product (R.A) of a variety of contacts on CVD graphene. In particular, we compared the R.A products of alumina and magnesium oxide tunnel barriers grown by sputteringmore » deposition of aluminum or magnesium and subsequent natural oxidation under pure oxygen atmosphere or by plasma. When using an alumina tunnel barrier on CVD graphene, the R.A product is high and exhibits a large dispersion. This dispersion can be highly reduced by using a magnesium oxide tunnel barrier, as for the R.A value. This study gives insight in the material quest for reproducible and efficient spin injection in CVD graphene.« less

  12. CAB-Align: A Flexible Protein Structure Alignment Method Based on the Residue-Residue Contact Area.

    PubMed

    Terashi, Genki; Takeda-Shitaka, Mayuko

    2015-01-01

    Proteins are flexible, and this flexibility has an essential functional role. Flexibility can be observed in loop regions, rearrangements between secondary structure elements, and conformational changes between entire domains. However, most protein structure alignment methods treat protein structures as rigid bodies. Thus, these methods fail to identify the equivalences of residue pairs in regions with flexibility. In this study, we considered that the evolutionary relationship between proteins corresponds directly to the residue-residue physical contacts rather than the three-dimensional (3D) coordinates of proteins. Thus, we developed a new protein structure alignment method, contact area-based alignment (CAB-align), which uses the residue-residue contact area to identify regions of similarity. The main purpose of CAB-align is to identify homologous relationships at the residue level between related protein structures. The CAB-align procedure comprises two main steps: First, a rigid-body alignment method based on local and global 3D structure superposition is employed to generate a sufficient number of initial alignments. Then, iterative dynamic programming is executed to find the optimal alignment. We evaluated the performance and advantages of CAB-align based on four main points: (1) agreement with the gold standard alignment, (2) alignment quality based on an evolutionary relationship without 3D coordinate superposition, (3) consistency of the multiple alignments, and (4) classification agreement with the gold standard classification. Comparisons of CAB-align with other state-of-the-art protein structure alignment methods (TM-align, FATCAT, and DaliLite) using our benchmark dataset showed that CAB-align performed robustly in obtaining high-quality alignments and generating consistent multiple alignments with high coverage and accuracy rates, and it performed extremely well when discriminating between homologous and nonhomologous pairs of proteins in both

  13. The impact of occlusal plane cant along with gingival display on smile attractiveness.

    PubMed

    Kaya, B; Uyar, R

    2016-05-01

    To evaluate the influence of occlusal plane cant in conjunction with maxillary gingival display on perception of smile attractiveness by orthodontists, dentists, and laypersons. Faculty of Dentistry at Baskent University. A total of 204 raters for smile attractiveness. A frontal intra-oral photograph of aligned teeth was modified using image processing software. Six different occlusal lines representing 0° to 5° cants were obtained by tilting the photographs. Each occlusal cant was adjusted in five manners resulting in five different gingival display amounts. Attractiveness of the 30 different smiles was evaluated by 204 raters divided into three groups (n = 68 in each group). Both occlusal cant (p < 0.001) and gingival display amount (p < 0.001) had a statistically significant influence on smile attractiveness. Smile attractiveness scores with reference to amount of gingival display showed a significant difference between rater groups (p < 0.001). Orthodontists preferred 1-mm coverage of upper central incisors by the upper lip, whereas dentists and laypersons preferred 2 mm. Significant (p < 0.001) interaction was observed between occlusal cant and gingival display amount, which influenced smile attractiveness. Increase in both occlusal plane cant and gingival display negatively influences smile attractiveness. The influence of occlusal plane cant becomes less when gingival display increases, whereas the influence of gingival display decreases when occlusal cant increases. Dentists are more generous than orthodontists, while laypersons are the most generous regarding smile attractiveness scores. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. A contact-area model for rail-pads connections in 2-D simulations: sensitivity analysis of train-induced vibrations

    NASA Astrophysics Data System (ADS)

    Ferrara, R.; Leonardi, G.; Jourdan, F.

    2013-09-01

    A numerical model to predict train-induced vibrations is presented. The dynamic computation considers mutual interactions in vehicle/track coupled systems by means of a finite and discrete elements method. The rail defects and the case of out-of-round wheels are considered. The dynamic interaction between the wheel-sets and the rail is accomplished by using the non-linear Hertzian model with hysteresis damping. A sensitivity analysis is done to evaluate the variables affecting more the maintenance costs. The rail-sleeper contact is assumed extended to an area-defined contact zone, rather than a single-point assumption which fits better real case studies. Experimental validations show how prediction fits well experimental data.

  15. Ventilation Increases with Lower Extremity Venous Occlusion in Young Adults

    PubMed Central

    Keller-Ross, Manda L.; Cowl, Andrielle L.; Cross, Troy; Johnson, Bruce D.; Olson, Thomas P.

    2015-01-01

    Introduction Venous distention via sub-systolic occlusion of the lower limbs may augment ventilation via stimulation of group III/IV afferent neurons. Purpose The purpose of this study was to examine the ventilatory response to graded lower extremity venous occlusion during exercise in healthy adults. Methods Nineteen adults (9 men, 25±5 yr) completed two visits. Visit 1: a maximal cycle ergometry exercise test. Visit 2 included a 30% peak workload cycle exercise with randomized inflations of bilateral thigh pressure tourniquets to 20, 40, 60, 80, 100 mmHg for 2 min each, separated by 2 min of deflation. Three min of cycling occurred prior to cuffing (CTL). Expired minute ventilation (VE), whole body gas exchange, rating of perceived exertion and dyspnea were measured during each session. Results VE increased significantly from the control condition (exercise only, control, CTL) to each occlusion pressure (p<0.05) with the greatest increase at 100 mmHg (CTL to 100 mmHg: 31.5±6.6 to 40.1±10.7 L/min). Respiratory rate (RR) increased as well (CTL to 100 mmHg: 24.8±6.0 to 30.9±11.5 breaths/min, p<0.05, condition effect) with no change in tidal volume (p>0.05). Tidal volume to inspiratory time (VT/TI) increased significantly from the CTL condition to each occlusion pressure (CTL to 100 mmHg: 1.5±0.3 to 1.8±0.4 L/min, p<0.05, all pressures). Dyspnea and RPE increased with all occlusion pressures from CTL exercise (p<0.05, all pressures). Conclusion Our findings suggest that mild-to-moderate venous occlusion of the lower extremity evokes a tachypneic breathing pattern which, in turn, augments VE and perceived breathing effort during exercise. PMID:26484951

  16. Estimating the Contact Endurance of the AISI 321 Stainless Steel Under Contact Gigacycle Fatigue Tests

    NASA Astrophysics Data System (ADS)

    Savrai, R. A.; Makarov, A. V.; Osintseva, A. L.; Malygina, I. Yu.

    2018-02-01

    Mechanical testing of the AISI 321 corrosion resistant austenitic steel for contact gigacycle fatigue has been conducted with the application of a new method of contact fatigue testing with ultrasonic frequency of loading according to a pulsing impact "plane-to-plane" contact scheme. It has been found that the contact endurance (the ability to resist the fatigue spalling) of the AISI 321 steel under contact gigacycle fatigue loading is determined by its plasticity margin and the possibility of additional hardening under contact loading. It is demonstrated that the appearance of localized deep and long areas of spalling on a material surface can serve as a qualitative characteristic for the loss of the fatigue strength of the AISI 321 steel under impact contact fatigue loading. The value of surface microhardness measured within contact spots and the maximum depth of contact damages in the peripheral zone of contact spots can serve as quantitative criteria for that purpose.

  17. Neural substrates of dynamic object occlusion.

    PubMed

    Shuwairi, Sarah M; Curtis, Clayton E; Johnson, Scott P

    2007-08-01

    In everyday environments, objects frequently go out of sight as they move and our view of them becomes obstructed by nearer objects, yet we perceive these objects as continuous and enduring entities. Here, we used functional magnetic resonance imaging with an attentive tracking paradigm to clarify the nature of perceptual and cognitive mechanisms subserving this ability to fill in the gaps in perception of dynamic object occlusion. Imaging data revealed distinct regions of cortex showing increased activity during periods of occlusion relative to full visibility. These regions may support active maintenance of a representation of the target's spatiotemporal properties ensuring that the object is perceived as a persisting entity when occluded. Our findings may shed light on the neural substrates involved in object tracking that give rise to the phenomenon of object permanence.

  18. Occlusion pressures in men rebreathing CO2 under methoxyflurane anesthesia.

    PubMed

    Derenne, J P; Couture, J; Iscoe, S; Whitelaw, A; Milic-Emili, J

    1976-05-01

    The effect of general anesthesia on control of breathing was studied by CO2 rebreathing and occlusion pressure measurements in six normal human subjects under methoxyflurane anesthesia. CO2 was found to increase the amplitude of the occlusion pressure wave without changing its shape, so that CO2 responses in terms of the occlusion pressure developed 100 ms after the onset of inspiration (Po/0.1) gave results equivalent to the responses in terms of Po/1.o or any other parameter of the pressure wave. Methoxyflurane depressed the ventilatory response to CO2 but not the occlusion pressure response, implying that the most important action of the anesthetic was to increase the effective elastance of the respiratory system rather than to depress the respiratory centers. The elastance was further increased by CO2, and this mechanical change had the effect of shifting the "apneic threshold" extrapolated from the ventilatory response curve to a lower PAco2. Frequency of breathing, inspiratory and expiratory times were not altered by CO2 in anesthetized subjects.

  19. The Study of the Impacts of "Running" on the Contact Area of Soles and Maximal Strength among Elite Middle Distance Runners

    ERIC Educational Resources Information Center

    Uzun, Ahmet; Aydos, Latif; Kaya, Metin; Yuksel, Mehmet Fatih; Pekel, Haci Ahmet

    2017-01-01

    It is possible that running training for many years in athletics affects athletes' running patterns and sole structure. The main aim of this study is to examine the effect of maximal force applied to the floor area and contact area of the athletes with related to mid-distance training for athletics. 18 male athletes who represent Turkey on the…

  20. [A cephalometric study on determining the orientation of occlusal plane].

    PubMed

    Xie, J; Zhao, Y; Chao, Y; Luo, W

    1993-12-01

    A study of the parallel relationship between the occlusal plane and the line connecting nasal alar and tragus was made in 90 dentulous cases by using cephalometry. The results show that the line connecting the inferior point of nasal alar and the mid-point of tragus runs much more parallel with the occlusal plane. The regression equation reveals a "line of closest fitting". It was used in the prosthetic treatment for 50 edentulous patients with good clinical results. The line connecting the inferior point of nasal alar and the mid-point of tragus therefore represents a proper reference plane for determining occlusal plane and hence should be still a valuable index in clinical dentistry.

  1. A Novel Nitinol Spherical Occlusion Device for Liver Cancer

    PubMed Central

    Hsiao, Hao-Ming; Wang, Yi-Ping; Ko, Chun-Yi; Cheng, Yu-Han; Lee, Han-Yu

    2016-01-01

    Liver cancer or hepatic cancer is a cancer that originates in the liver. It is formed from either the liver itself or from structures within the liver, including blood vessels or the bile duct. Liver cancer can be a life-threatening condition, but it may be cured if found early. Hepatic artery embolization is one of the treatment options involving the injection of substances to reduce the blood flow to cancer cells in the livers of patients with tumors that cannot be removed by surgery; however, this treatment has some limitations. In this paper, we propose a novel nitinol “spherical occlusion device” concept, the first of its kind in the world. Our proposed spherical occlusion device is able to reduce the blood flow to cancer cells by deploying it in the upstream hepatic artery supplying blood to the liver. Moreover, it could carry multiple chemotherapy or radioactive drugs for delivery directly to the target site. Nitinol alloy was chosen as the device material due to its excellent super-elastic property. Computational models were developed to predict the mechanical response of the device during manufacturing and deployment procedures, as well as its hemodynamic behavior. Simulation results showed that the presence of the spherical occlusion device with 14%–27% metal density deployed at the upstream location of the right hepatic artery had significant occlusion effects, with the average blood flow rate cut down by 30%–50%. A pulsed fiber laser and a series of expansions and heat treatments were developed to make the first prototype of the spherical occlusion device for the demonstration of our novel concept. PMID:28787820

  2. Incidence and Determinants of Port Occlusions in Cancer Outpatients: A Prospective Cohort Study.

    PubMed

    Milani, Alessandra; Mazzocco, Ketti; Gandini, Sara; Pravettoni, Gabriella; Libutti, Livio; Zencovich, Claudia; Sbriglia, Ada; Pari, Chiara; Magon, Giorgio; Saiani, Luisa

    Normal saline is considered a safe alternative for heparin as a locking solution in totally implantable venous access devices. The incidence rate of partial occlusion with the use of normal saline (easy injection, impossible aspiration) is estimated at 4%. The aim of this study was to investigate determinants of partial occlusions with the use of normal saline solution and the maintenance of positive pressure in the catheter. We enrolled 218 patients with different solid tumors who underwent pharmacologic treatment through the port with different frequencies: from once every week to at least once every month. The port was flushed with normal saline solution keeping a positive pressure in the catheter. We performed 4111 observations and documented normal port functioning in 99% of observations (n = 4057) and partial occlusions in 1% of observations (n = 54). Partial occlusions were significantly associated with frequency of port flushing (P < .05), chemotherapy (P < .001), and blood sample collection (P < .001). The use of positive pressure in addition to normal saline reduces the incidence rate of partial occlusions. The type of treatment, blood sample collection, and treatment schedule are important determinants of partial occlusions. Nurses play a key role in maintaining a functioning port using positive pressure during the flushing techniques. Certain risk factors must be monitored to prevent partial occlusions, and certain patients are more likely to present with port-related problems.

  3. Occlusion pressure analysis role in partitioning of pulmonary vascular resistance in CTEPH.

    PubMed

    Toshner, Mark; Suntharalingam, Jay; Fesler, Pierre; Soon, Elaine; Sheares, Karen K; Jenkins, David; White, Paul; Morrell, Nicholas W; Naeije, Robert; Pepke-Zaba, Joanna

    2012-09-01

    Flow-directed pulmonary artery occlusion is posited to enable partitioning of vascular resistance into small and large vessels. As such it may have a role in assessment for pulmonary endarterectomy. To test if the occlusion technique distinguished small from large vessel disease we studied 59 subjects with chronic thromboembolic pulmonary hypertension (CTEPH), idiopathic pulmonary arterial hypertension (IPAH), and connective tissue disease (CTD)-associated PAH. At right heart catheterisation, occlusion pressures were recorded. With fitting of the pressure decay curve, pulmonary vascular resistance was partitioned into downstream (small vessels) and upstream (large vessels, Rup). 47 patients completed the study; 14 operable CTEPH, 15 inoperable CTEPH, 13 idiopathic or CTD-PAH and five post-operative CTEPH. There was a significant difference in mean Rup in the proximal operable CTEPH group 87.3 (95% CI 84.1-90.5); inoperable CTEPH mean 75.8 (95% CI 66.76-84.73), p=0.048; and IPAH/CTD, mean 77.1 (95% CI 71.86-82.33), p=0.003. Receiver operating characteristic curves to distinguish operable from inoperable CTEPH demonstrated an area under the curve of 0.75, p=0.0001. A cut-off of 79.3 gave 100% sensitivity (95% CI 73.5-100%) but 57.1% specificity (95% CI 28.9-82.3%). In a subgroup analysis of multiple lobar sampling there was demonstrable heterogeneity. Rup is significantly increased in operable proximal CTEPH compared with non-operable distal CTEPH and IPAH/CTD-PAH. Rup variability in patients with CTEPH and PAH is suggestive of pathophysiological heterogeneity.

  4. Liver size, bodyweight, and tolerance to acute complete occlusion of congenital extrahepatic portosystemic shunts in dogs.

    PubMed

    Doran, Ivan P; Barr, Frances J; Hotston Moore, Alasdair; Knowles, Toby G; Holt, Peter E

    2008-10-01

    To investigate the relationship between preoperative liver size, bodyweight, and tolerance to shunt occlusion in dogs with congenital extrahepatic portosystemic shunt(s) (CPSS). Longitudinal cohort study. Dogs with CPSS (n=35). Ultrasonography was used to measure preoperative maximum transverse dimension of the liver (TS) of each dog. Intraoperative portal pressures were measured, before and after CPSS occlusion, via a jejunal vein catheter. Tolerance to shunt occlusion was judged on gross visceral observations, and on changes in portal pressure, central venous and mean arterial pressures. TS was significantly related to bodyweight (P<.05). Mean ratios for TS/bodyweight were calculated for dogs tolerant and intolerant of acute complete shunt occlusion. Dogs tolerant to occlusion had significantly higher TS/bodyweight ratios than dogs intolerant to occlusion (P=.025). Dogs with a TS/bodyweight ratio of >7 were more likely to tolerate CPSS occlusion than dogs with a TS/bodyweight ratio of <5 (P=.036). A model was generated to predict portal pressure rise after shunt occlusion, based on liver dimensions and bodyweight (R=0.668). Intestinal oxygenation did not correlate significantly with tolerance to CPSS occlusion (P=.29). In dogs with CPSS, liver size (relative to bodyweight) is significantly greater (P=.025) in dogs that are tolerant of full ligation than intolerant of occlusion. Preoperative measurement of bodyweight and liver size help indicate the likelihood of tolerance to acute complete occlusion of CPSS in dogs.

  5. A prospective randomized comparison of continuous hemihepatic with intermittent total hepatic inflow occlusion in hepatectomy for liver tumors.

    PubMed

    Liang, Guanlin; Wen, Tianfu; Yan, Lunan; Li, B O; Wu, Guochang; Yang, Jian; Lu, Bo; Chen, Zheyu; Liao, Zhixue; Ran, Shun; Yu, Zhang

    2009-01-01

    To evaluate whether continuous hemihepatic inflow occlusion (HHO) during hepatectomy can be safer than and be as effective as intermittent total hepatic inflow occlusion (THO) in reducing blood loss. Eighty patients undergoing liver resections were included in a prospective randomized study comparing the intra- and postoperative course under THO (n=40) or HHO (n=40). THO was performed with periods of 20 minutes of occlusion and 5 minutes of releasing, while HHO was performed with continuous occlusion. The surface area of liver transection, amount of blood loss, measurements of alanine aminotransferase (ALT) and aspartate aminotransferase (AST), and postoperative evolution were recorded. The two groups were similar at entry in terms of preoperative liver function and in the proportion of patients experiencing major hepatectomy. The total ischemic time of the two groups was similar (p=0.37), but the operative time in the THO group was longer than in the HHO group (p=0.02). No significant difference was found between the HHO and THO group in blood loss during liver parenchyma transection (p=0.14), the elevations of ALT and AST on the first postoperative day (ALT: p=0.12; AST: p=0.66) and postoperative morbidity (p=0.35). On the basis of our findings, if it is feasible, continuous HHO is recommended for complex liver resection.

  6. Lower Body Positive Pressure Application with an Antigravity Suit in Acute Carotid Occlusion

    PubMed Central

    Berthet, Karine; Lukaszewicz, Anne Claire; Bousser, Marie-Germaine; Payen, Didier

    2010-01-01

    The challenge in acute stroke is still to reperfuse as early as possible the ischemic territory. Since fibrinolytic therapies have a limited window with potential risk of bleeding, having a nonpharmacologic mean to recruit vessels in area surrounding necrosis might be useful. We propose here to use antigravity suit inflated at “venous” pressure levels to shift blood towards thoracic and brain territories. We report two cases of spectacular clinical recovery after acute carotid occlusion. PMID:20798842

  7. Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee.

    PubMed

    Lee, Stephen J; Aadalen, Kirk J; Malaviya, Prasanna; Lorenz, Eric P; Hayden, Jennifer K; Farr, Jack; Kang, Richard W; Cole, Brian J

    2006-08-01

    There is no consensus regarding the extent of meniscectomy leading to deleterious effects on tibiofemoral contact mechanics. The meniscus aids in optimizing tibiofemoral contact mechanics, increasing contact area, and decreasing contact stress. Controlled laboratory study. Twelve fresh-frozen human cadaveric knees each underwent 15 separate testing conditions-5 serial 20-mm posterior medial meniscectomy conditions (intact, 50% radial width, 75% radial width, segmental, and total meniscectomy) at 3 flexion angles (0 degrees , 30 degrees , and 60 degrees )-under an 1800-N axial load. Tekscan sensors were used to measure total force and medial force, contact area, mean contact stress, and peak contact stress. All posterior medial meniscectomy conditions resulted in significantly decreased contact areas and increased mean and peak contact stresses compared with the intact state (P < .05). The changes in contact mechanics after segmental and total posterior medial meniscectomies were not statistically different (P > .05). Incremental changes in contact area and mean contact stress increased as more peripheral portions of the medial meniscus were removed, whereas peak contact stresses exhibited similar incremental changes throughout all meniscectomy conditions. The meniscus is a crucial load-bearing structure, optimizing contact area and minimizing contact stress. Loss of hoop tension (ie, segmental meniscectomy) is equivalent to total meniscectomy in load-bearing terms. The peripheral portion of the medial meniscus provides a greater contribution to increasing contact areas and decreasing mean contact stresses than does the central portion, whereas peak contact stresses increase proportionally to the amount of meniscus removed. Because the degree of meniscectomy leading to clinically significant outcomes is unknown, a prudent strategy is to preserve the greatest amount of meniscus possible.

  8. Occlusal plane rotation: aesthetic enhancement in mandibular micrognathia.

    PubMed

    Rosen, H M

    1993-06-01

    Patients afflicted with extreme degrees of mandibular micrognathia typically have vertically deficient rami as well as sagittally deficient mandibular bodies. This results in deficient posterior facial height, an obtuse gonial angle, excessively steep occlusal and mandibular planes, and a compensatory increase in anterior facial height. The entire maxillomandibular complex is overrotated in a clockwise direction. Standard orthognathic surgical correction fails to address this rotational deformity. As a consequence, the achieved projection of the lower face is inadequate, posterior facial height is further reduced, and occlusal and mandibular planes remain steep. Eleven patients with severe mandibular micrognathia underwent a surgical correction involving occlusal plane rotation to its normal orientation relative to Frankfort horizontal. This was accomplished by Le Fort I osteotomy to shorten the anterior maxilla (creating open bites in seven patients and making preexisting open bites worse in four patients) and sagittal split ramus osteotomies to advance and rotate the mandibular body counterclockwise, thus closing the surgically produced open bite. Counterclockwise rotation of the mandible afforded significantly greater sagittal displacement at the B point (mean 17 mm) than at the first molar (mean 10 mm) and produced adequate degrees of projection of the lower face when accompanied by a modest sliding genioplasty (mean 6.9 mm). Total advancement at the pogonion was a mean of 25.2 mm. In addition, posterior facial height was preserved, and mandibular and occlusal planes were normalized to mean angles of 27 and 10 degrees, respectively. At follow-up, which ranged from 9 to 24 months with a mean of 14.1 months, the mean sagittal relapse at the B point was 1.9 mm. Although heretofore considered unstable and therefore not clinically accepted, maxillomandibular counterclockwise rotation to normalize the occlusal plane rotational deformity provides stable, aesthetically

  9. Amplatzer vascular plug for arteriovenous hemodialysis access occlusion: initial experience.

    PubMed

    Bui, J T; Gaba, R C; Knuttinen, M G; West, D L; Owens, C A

    2009-01-01

    The Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN) is a recently developed self-expanding metallic device indicated for peripheral vascular embolizations. Herein, we describe use of this device in the treatment of vascular complications related to arteriovenous hemodialysis fistulas and grafts. This HIPAA compliant retrospective study was approved by the institutional review board with informed consent waived. Six patients with problematic arteriovenous access underwent access occlusion using the AVP. Procedure indications included vascular steal syndrome in five patients, and enlarging vascular aneurysms in one patient. Contraindications for surgical correction were determined by the referring surgeon. AVP embolizations were performed using devices oversized by 50% introduced through vascular sheaths positioned within vein segments just beyond the arteriovenous anastomoses. Noninvasive evaluation of the involved extremity was performed pre- and post-embolization in addition to clinical follow-up examinations. Measured outcomes included success of angiographic occlusion, improvement in distal arterial flow, AVP number, AVP diameter, time to access occlusion, and clinical symptomatic improvement. Technical success was 100%, with complete arteriovenous access occlusion accomplished in all cases, with an average of 1.5 AVPs used per patient. Mean time to access occlusion was 19.3 minutes. Angiographic improvement in distal arterial flow was immediately evident and resolution of clinical symptoms occurred in all patients, with mean long-term follow-up of 16 months. No procedure-related complications were encountered. The Amplatzer Vascular Plug provides a minimally invasive and efficacious method for embolization of problematic arteriovenous hemodialysis access.

  10. Patching compliance with full-time vs. part-time occlusion therapy.

    PubMed

    Kane, Jessica; Biernacki, Ron; Fraine, Lisa; Fukuda, Neva; Haskins, Kelsie; Morrison, David G

    2013-01-01

    Amblyopia is commonly treated with part-time occlusion (PTO) therapy. We have made two anecdotal observations regarding this therapy. First, children undergoing full-time occlusion seem to have better success and compliance rates. Secondly, a subset of children exists that fail PTO but can improve with more aggressive therapy. A retrospective review where treatment, visual outcome, and compliance scores were recorded. Compliance was graded on percent adherence reported by family. Patients scored “1” (for no compliance), “2” (for 1–25% of prescribed treatment performed), “3” (for 26–50%), “4” (for 51–75%), or “5” (for 76–100%). Seventy-six children were enrolled in the study: forty-five were treated with part-time occlusion, twenty-two were treated with full time occlusion (FTO), and nine had a history of failed PTO and were subsequently treated with FTO. Visual outcomes for FTO versus PTO were not statistically significant (P = 0.82). However, compliance rates in FTO were significantly better (P = 0.02). Of the nine patients that failed PTO, four improved an average of three lines with full-time occlusion, and five had no change with more aggressive patching. This study confirms previous reports of similar visual outcomes between PTO and FTO. However, compliance rates for FTO seem to be higher and some children who have failed PTO may improve with FTO.

  11. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Nambiar, Ashwin, E-mail: uvashwin@gmail.com; Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Fivemore » arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.« less

  12. Evaluation of in-vehicle HMI using occlusion techniques: experimental results and practical implications.

    PubMed

    Baumann, Martin; Keinath, Andreas; Krems, Josef F; Bengler, Klaus

    2004-05-01

    Despite the usefulness of new on-board information systems one has to be concerned about the potential distraction effects that they impose on the driver. Therefore, methods and procedures are necessary to assess the visual demand that is connected to the usage of an on-board system. The occlusion-method is considered a strong candidate as a procedure for evaluating display designs with regard to their visual demand. This paper reports results from two experimental studies conducted to further evaluate this method. In the first study, performance in using an in-car navigation system was measured under three conditions: static (parking lot), occlusion (shutter glasses), and driving. The results show that the occlusion-procedure can be used to simulate visual requirements of real traffic conditions. In a second study the occlusion method was compared to a global evaluation criterion based on the total task time. It can be demonstrated that the occlusion method can identify tasks which meet this criterion, but are yet irresolvable under driving conditions. It is concluded that the occlusion technique seems to be a reliable and valid method for evaluating visual and dialogue aspects of in-car information systems.

  13. Contoured in-shoe foot orthoses increase mid-foot plantar contact area when compared with a flat insert during cycling.

    PubMed

    Bousie, Jaquelin A; Blanch, Peter; McPoil, Thomas G; Vicenzino, Bill

    2013-01-01

    To determine the effect of contouring of an in-shoe foot orthosis on plantar contact area and surface pressure, as well as perceived comfort and support at the foot-orthosis interface during stationary cycling. A randomised, repeated measures control study. Twelve cyclists performed steady-state seated cycling at a cadence of 90 rpm using a contoured orthosis and a flat insert of similar hardness. Contact area (CA) and plantar mean pressure (PP) were measured using the PEDAR® system, determined for seven discrete plantar regions and represented as the percentage of the total CA and PP respectively (CA% and PP%). Perceived comfort and support were rated using a visual analogue scale (VAS). The contoured orthosis produced a significantly greater CA% at the medial midfoot (p=0.001) and lateral midfoot (p=0.009) with a standardised mean difference (SMD) of 1.3 and 0.9 respectively. The contoured orthosis also produced a significantly greater PP% at the hallux (p=0.003) compared to the flat insert with a SMD of 1.1. There was a small non-significant effect (SMD<0.4) for the perceived comfort measures between conditions, but perceived support was significantly greater at the arch (p=0.000) and heel (p=0.013) with the contoured orthoses (SMD of 1.5 and 0.9, respectively). Contoured orthoses influenced the plantar surface of the foot by increasing contact area as well as a perception of greater support at the midfoot while increasing relative pressure through the hallux when compared to a flat insert during stationary cycling. No difference in perceived comfort was noted. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  14. Differences between Subjective Balanced Occlusion and Measurements Reported With T-Scan III

    PubMed Central

    Lila-Krasniqi, Zana; Shala, Kujtim; Krasniqi, Teuta Pustina; Bicaj, Teuta; Ahmedi, Enis; Dula, Linda; Dragusha, Arlinda Tmava; Guguvcevski, Ljuben

    2017-01-01

    BACKGROUND: The aetiology of Temporomandibular disorder is multifactorial, and numerous studies have addressed that occlusion may be of great importance in the pathogenesis of Temporomandibular disorder. AIM: The aim of this study is to determine if any direct relationship exists between balanced occlusion and Temporomandibular disorder and to evaluate the differences between subjective balanced occlusion and measurements reported with T-scan III electronic system. MATERIAL AND METHODS: A total of 54 subjects were divided into three groups, selection based on anamnesis-responded to a Fonseca questionnaire and clinical measurements analysed with electronic system T-scan III. In the I study group were participants with fixed dentures with prosthetic ceramic restorations. In the II study group were symptomatic participants with TMD. In the third control group were healthy participants with full arch dentition that completed a subjective questionnaire that documented the absence of jaw pain, joint noise, locking and subjects without a history of TMD. The occlusal balance was reported subjectively through Fonseca questionnaire and compared with occlusion analysed with electronic system T-scan III. RESULTS: For attributive data were used percentage of the structure. Differences in P < 0.05 were considered significant. After distributing attributive data of occlusal balance subjectively reported and compared with measurements analysed with electronic system T-scan III were found significant difference P < 0.001 in all three groups. CONCLUSION: In our study, it was concluded that there were statistically significant differences of balanced occlusion in all three groups. Also it was concluded that subjective data are not exact with measurements reported with electronic device T-scan III. PMID:28932311

  15. Comparative study to evaluate the accuracy of polyether occlusal bite registration material and occlusal registration wax as a guide for occlusal reduction during tooth preparation.

    PubMed

    Joshi, Niranjan; Shetty, Sridhar N; Prasad, Krishna D

    2013-01-01

    The use of different materials and techniques has been studied to decide the safest quantum of reduction of the occlusal surfaces. However, these methods provide limited information as to the actual amount of reduction with limitations in accuracy, accessibility and complexity. The objective of this study was to compare and evaluate the reliability of the most commonly used occlusal registration wax that with polyether bite registration material as a guide for occlusal reduction required during tooth preparations. For the purpose of this study, 25 abutment teeth requiring tooth preparation for fixed prosthesis were selected and tooth preparations carried out. Modeling wax strips of specific dimensions were placed onto the cast of prepared tooth, which was mounted on maximum intercuspation on the articulator and the articulator was closed. The thickness of the wax registration was measured at three zones namely two functional cusps and central fossa. Similar measurements were made using the polyether bite registration material and prosthesis at the same zones. The data was tabulated and was subjected to statistical analysis using anova test and Tukey honestly significant difference test. The differences in thickness between wax record and prosthesis by 0.1346 mm, whereas the difference between polyether and prosthesis was 0.02 mm with a P value of 0.042, which is statistically significant. This means that the wax record was 8.25% larger than the prosthesis while polyether was just 1.27% larger than the prosthesis. The clinical significance of the above analysis is that Ramitec polyether bite registration material is most suitable material when compared with commonly used modeling wax during the tooth preparation.

  16. Tibiofemoral contact stress and stress distribution evaluation of total knee arthroplasties.

    PubMed

    Szivek, J A; Cutignola, L; Volz, R G

    1995-08-01

    The Fuji film (Itochu, Los Angeles, CA) area analysis technique demonstrates that a more accurate assessment of tibiofemoral contact stresses is possible when the film is used at 37 degrees C and at the upper end of its sensitivity range (in this case, a 2,000-N load). An AMK with a regular and Hylamer-M insert (DePuy, Warsaw, IN), an MG II (Zimmer, Warsaw, IN), an Omnifit (Osteonics, Allendale, NJ), an Ortholoc III (Dow Corning Wright, Midland, MI), a PCA II (Howmedica, Rutherford, NJ), and a PFC (Johnson & Johnson Orthopaedics, Raynham, MA) had average contact stresses that varied only 12% at 60 degrees flexion. At 0 degrees, 15 degrees and 60 degrees flexion, stresses ranged from 13 to 25 MPa. Contact area distribution ratios, which were smaller at 37 degrees C than at 24 degrees C, provide a quantitative means of grouping implants according to the shape of the tibiofemoral contact area. The Omnifit, MG II, PCA II, and PFC had small ratios (symmetric areas). The AMK and Ortholoc III had large ratios (asymmetric contact areas). If the impression is reflective of wear, it would be expected to be focal in knees with small ratios and contact areas, and uniform in knees with large ratios and contact areas, whereas large ratios and small areas would imply a linear wear pattern. Calibrated electrical resistance contact stress measurements indicated that the Fuji film measurements underestimated the magnitude of contact stresses. They also provided a means of quantifying the rate of area increase during initial loading of the knees, with the highest area increase noted for the knee with the roughest insert (Ortholoc III) and the lowest area increase for the knee with the smoothest insert (PCA II).

  17. Interobserver variability in the assessment of aneurysm occlusion with the WEB aneurysm embolization system.

    PubMed

    Fiorella, David; Arthur, Adam; Byrne, James; Pierot, Laurent; Molyneux, Andy; Duckwiler, Gary; McCarthy, Thomas; Strother, Charles

    2015-08-01

    The WEB (WEB aneurysm embolization system, Sequent Medical, Aliso Viejo, California, USA) is a self-expanding, nitinol, mesh device designed to achieve aneurysm occlusion after endosaccular deployment. The WEB Occlusion Scale (WOS) is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with intrasaccular mesh implants. This study was performed to assess the interobserver variability of the WOS. Seven experienced neurovascular specialists were trained to apply the WOS. These physicians independently reviewed angiographic image sets from 30 patients treated with the WEB under blinded conditions. No additional clinical information was provided. Raters graded each image according to the WOS (complete occlusion, residual neck or residual aneurysm). Final statistics were calculated using the dichotomous outcomes of complete occlusion or incomplete occlusion. The interobserver agreement was measured by the generalized κ statistic. In this series of 30 test case aneurysms, observers rated 12-17 as completely occluded, 3-9 as nearly completely occluded, and 9-11 as demonstrating residual aneurysm filling. Agreement was perfect across all seven observers for the presence or absence of complete occlusion in 22 of 30 cases. Overall, interobserver agreement was substantial (κ statistic 0.779 with a 95% CI of 0.700 to 0.857). The WOS allows a consistent means of reporting angiographic occlusion for aneurysms treated with the WEB device. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. An Investigation of the Posterior Component of Occlusal Force

    DTIC Science & Technology

    1994-05-01

    of the hemostat allowed subjects to consistently orient the bite force transducer parallel to the occIusal plane , thus allowing the bite force to be...the anterior component of occlusal force was influenced by the steepness of the occlusal plane . Southard et al (1989) was the first to quantify the...young adult males yielded higher mean maximum bite forces at 20 mm opening and at 40 mm opening. The authors suggested that orientation and function of

  19. Pathophysiological mechanisms of high-intensity focused ultrasound-mediated vascular occlusion and relevance to non-invasive fetal surgery

    PubMed Central

    Shaw, C. J.; ter Haar, G. R.; Rivens, I. H.; Giussani, D. A.; Lees, C. C.

    2014-01-01

    High-intensity focused ultrasound (HIFU) is a non-invasive technology, which can be used occlude blood vessels in the body. Both the theory underlying and practical process of blood vessel occlusion are still under development and relatively sparse in vivo experimental and therapeutic data exist. HIFU would however provide an alternative to surgery, particularly in circumstances where serious complications inherent to surgery outweigh the potential benefits. Accordingly, the HIFU technique would be of particular utility for fetal and placental interventions, where open or endoscopic surgery is fraught with difficulty and likelihood of complications including premature delivery. This assumes that HIFU could be shown to safely and effectively occlude blood vessels in utero. To understand these mechanisms more fully, we present a review of relevant cross-specialty literature on the topic of vascular HIFU and suggest an integrative mechanism taking into account clinical, physical and engineering considerations through which HIFU may produce vascular occlusion. This model may aid in the design of HIFU protocols to further develop this area, and might be adapted to provide a non-invasive therapy for conditions in fetal medicine where vascular occlusion is beneficial. PMID:24671935

  20. Dental Occlusion and Ophthalmology: A Literature Review

    PubMed Central

    Marchili, Nicola; Ortu, Eleonora; Pietropaoli, Davide; Cattaneo, Ruggero; Monaco, Annalisa

    2016-01-01

    Stomatognathic system is strictly correlated to other anatomical regions; many studies investigated relationship between temporomandibular joint and posture, several articles describe cranio-facial pain from dental causes, such as trigger points. Until now less interest has been given to connections between dental occlusion and ophthalmology, even if they are important and involving. Clinical experience in dental practice claims that mandibular latero-deviation is connected both to eye dominance and to defects of ocular convergence. The trigeminal nerve is the largest and most complex of the twelve cranial nerves. The trigeminal system represents the connection between somitic structures and those derived from the branchial arches, collecting the proprioception from both somitic structures and oculomotor muscles. The intermedius nucleus of the medulla is a small perihypoglossal brainstem nucleus, which acts to integrate information from the head and neck and relays it on to the nucleus of the solitary tract where autonomic responses are generated. This intriguing neurophysiological web led our research group to investigate anatomical and functional associations between dental occlusion and vision. In conclusion, nervous system and functional pathways strictly connect vision and dental occlusion, and in the future both dentists and oculists should be more and more aware of this correlation for a better diagnosis and therapy. PMID:27733873

  1. Effects of tissue conductivity and electrode area on internal electric fields in a numerical human model for ELF contact current exposures

    NASA Astrophysics Data System (ADS)

    Tarao, H.; Kuisti, H.; Korpinen, L.; Hayashi, N.; Isaka, K.

    2012-05-01

    Contact currents flow through the human body when a conducting object with different potential is touched. There are limited reports on numerical dosimetry for contact current exposure compared with electromagnetic field exposures. In this study, using an anatomical human adult male model, we performed numerical calculation of internal electric fields resulting from 60 Hz contact current flowing from the left hand to the left foot as a basis case. Next, we performed a variety of similar calculations with varying tissue conductivity and contact area, and compared the results with the basis case. We found that very low conductivity of skin and a small electrode size enhanced the internal fields in the muscle, subcutaneous fat and skin close to the contact region. The 99th percentile value of the fields in a particular tissue type did not reliably account for these fields near the electrode. In the arm and leg, the internal fields for the muscle anisotropy were identical to those in the isotropy case using a conductivity value longitudinal to the muscle fibre. Furthermore, the internal fields in the tissues abreast of the joints such as the wrist and the elbow, including low conductivity tissues, as well as the electrode contact region, exceeded the ICNIRP basic restriction for the general public with contact current as the reference level value.

  2. Sperm characteristics and teratology in rats following vas deferens occlusion with RISUG and its reversal.

    PubMed

    Lohiya, N K; Suthar, R; Khandelwal, A; Goyal, S; Ansari, A S; Manivannan, B

    2010-02-01

    The functional success of the reversal of vas occlusion by styrene maleic anhydride (RISUG), using the solvent vehicle, Dimethyl Sulphoxide (DMSO), has been investigated. Reversal with DMSO was carried out in Wistar albino rats 90 days after bilateral vas occlusion. The body weight, organ weight, sperm characteristics, fertility test and teratology, including skeletal morphology were evaluated in vas occlusion and reversal animals and in F(1) progenies to assess the functional success of the occlusion and reversal. Body weight, organ weight and the cauda epididymal sperm characteristics of vas occlusion and reversal animals and of F(1) progenies were comparable to control. Ejaculated spermatozoa in the vaginal smear showed detached head/tail, acrosomal damage, bent midpiece, bent tail and morphological aberrations in sperm head after vas occlusion, which returned to normal, 90 days after reversal. Monthly fertility test, post-injection showed 0% fertility, which improved gradually and 100% fertility was achieved 90 days after reversal. The fertility/pregnancy/implantation record and skeletal morphology of the offspring were comparable to control. The results suggest functional success and safety of vas occlusion reversal by DMSO.

  3. A 57-year follow-up study of occlusion. Part 3: Oral health and attitudes to teeth among individuals with crossbite at the age of 8 years.

    PubMed

    Berg, Rolf Elling; Espeland, Lisen; Stenvik, Arild

    2008-11-01

    To analyze occlusal changes occurring between the ages of 8 and 65 years in persons with anterior and/or posterior crossbite at the age of 8; to examine their attitudes toward dental appearance and their experiences related to their own teeth. Of the 81 people we contacted who had been documented as having crossbite as 8-year-olds in 1950, 21 agreed to participate in this follow-up study. Their occlusal conditions had been documented initially by intraoral photographs in 1950, and a clinical examination including facial photographs, further occlusal photographs and an interview took place in 2007. For comparison, we also had available similarly-documented examples of individuals (n = 18) of the same age and with normal occlusion in 1950. Oral hygiene was good or excellent in all individuals and all but one visited their dentist regularly. The average number of missing teeth was 3.8, whereas in the normal occlusion sample that number was 1.6. Of the eight persons who had undergone minor orthodontic treatment during childhood, five had an anterior crossbite resolved. Four persons who had initially presented a posterior crossbite later developed an anterior crossbite as well. In 2007, eleven individuals had a posterior and eight an anterior crossbite. At 65, four persons remembered that they had been teased in childhood because of their teeth, and could still remember the terms that had been used. Eighteen persons were satisfied with their teeth although two had severe anterior crossbite; three were dissatisfied, and their reasons were general health problems, mild crowding, and dentofacial asymmetry. Seven persons had TMJ symptoms with various types of history. With three exceptions, they all considered good tooth position to be important or very important. In those not orthodontically treated, malocclusion tended to worsen, although 18 of the 21 persons expressed satisfaction with their teeth as adults. They had a higher average number of missing teeth, and more had

  4. Occlusal characteristics of children with hypertrophied adenoids in Nigeria.

    PubMed

    Osiatuma, Vivien Ijeoma; Otuyemi, Olayinka Donald; Kolawole, Kikelomo Adebanke; Ogunbanjo, Babatunde Ogunbiyi; Amusa, Yemisi Bola

    2015-03-01

    Nasorespiratory function and its relation to craniofacial growth are of great interest because of the basic biological relationship between form and function, and the accumulating findings of the relationship between mode of breathing, craniofacial growth and orthodontic treatment. The aim of this study was to evaluate the effect of adenoid hypertrophy and sociodemographic variables on the occlusion of children. A total of 180 subjects aged 3-12 years were selected at the Obafemi Awolowo University Teaching Hospital Complex, Ile-Ife, Nigeria. Ninety subjects had hypertrophied adenoids while 90 normal children served as the control group. Orthodontic examinations were carried out and impressions for study models taken. Occlusion was assessed in the anterior-posterior, transverse and vertical planes. Class I relationship was the most prevalent occlusion in both adenoid and control subjects (55.6% and 72.2%, respectively). The occurrence of class II division 1 was significantly higher among adenoid than control subjects (P=0.003). Posterior crossbites occurred significantly more in adenoid subjects in the 9-12 years category. In the vertical plane, the occurrence of deep bite was significantly greater in male than female adenoid subjects. Age had a statistically significant but weak correlation with anterior open bite (r=0.37). Age and BMI also had significant though weak correlations with posterior crossbite in female adenoid subjects (r=0.39 and r=0.36, respectively). Regression analysis also showed that age had a significant effect on the occurrence of anterior open bite, while BMI had a significant effect on the occurrence of class II occlusion in adenoid subjects (P<0.05). The presence of hypertrophied adenoids affects the occlusion in the three planes. Age and BMI have significant effects on the occurrence of anterior open bite and class II division 1 malocclusion respectively in adenoid subjects. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. [Evaluation of visual acuity in a historical cohort of 137 patients treated for amblyopia by occlusion 30-35 years ago].

    PubMed

    Simonsz-Tóth, B; Loudon, S E; van Kempen-du Saar, H; van de Graaf, E S; Groenewoud, J H; Simonsz, H J

    2007-01-01

    Opinions differ on the course of the visual acuity in the amblyopic eye after cessation of occlusion therapy. This study evaluated visual acuity in a historical cohort treated for amblyopia with occlusion therapy 30-35 years ago. Between 1968 and 1975, 1250 patients had been treated by the orthoptist in the Waterland Hospital in Purmerend, The Netherlands. Of these, 471 received occlusion treatment for amblyopia (prevalence 5.0%, after comparison with the local birth rate). We were able to contact 203 of these patients, 137 were orthoptically re-examined in 2003. We correlated the current visual acuity with the cause of amblyopia, the age at start and end of treatment, the visual acuity at start and end of treatment, fixation, binocular vision and refractive errors. Mean age at the start of treatment was 5.4 +/- 1.9 years, 7.4 +/- 1.7 years at the end and 37 +/- 2.7 years at follow-up. Current visual acuity in the amblyopic eye was correlated with a low visual acuity at the start (p < 0.0001) and end (p < 0.0001) of occlusion therapy, an eccentric fixation (p < 0.0001), and the cause of amblyopia (p = 0.005). At the end of the treatment, patients with a strabismic amblyopia (n = 98) had a visual acuity in the amblyopic eye of 0.29 logMAR +/- 0.3, and in 2003 0.27 +/- 0.3 logMAR. In patients with an anisometropic amblyopia (> 1 D, n = 16) visual acuity had decreased from 0.17 +/- 0.23 logMAR to 0.21 logMAR +/- 0.23. In patients with both strabismic and anisometropic amblyopia (n = 23), visual acuity had decreased from 0.52 logMAR +/- 0.54 to 0.65 logMAR +/- 0.54. Overall, acuity had decreased in 54 patients (39%) after cessation of treatment. Of these, 18 patients had an acuity decrease to less than 50% of their acuity at the end of treatment. In 15 of these 18 patients anisohypermetropia had increased. A decrease in visual acuity after cessation of occlusion therapy occurred in patients with a combined cause of amblyopia or with an increase in anisohypermetropia.

  6. SWIR reflectance imaging of demineralization on the occlusal surfaces of teeth beyond 1700 nm

    NASA Astrophysics Data System (ADS)

    Ng, Chung; Simon, Jacob C.; Fried, Daniel; Darling, Cynthia L.

    2018-02-01

    Most new lesions are found in the pits and fissures of the occlusal surface. Radiographs have extremely low sensitivity for early occlusal decay and by the time the lesion is severe enough on a radiograph it typically has penetrated well into the dentin and surgical intervention is required. The occlusal surfaces are heavily stained and visual and tactile methods for their detection also have poor sensitivity and specificity. Previous studies at wavelengths beyond 1300-nm have demonstrated that stains are not visible and demineralization on the occlusal surfaces can be viewed without interference from stains. New extended range InGaAs near- IR cameras allow access to wavelengths beyond 1700-nm. The objective of this study was to determine how the contrast of occlusal lesions varies with wavelength from the visible to 2350-nm. The lesion contrast was measured in 55 extracted teeth with suspected occlusal lesions using reflectance measurements from 400- 2350-nm using Si and InGaAs imaging arrays. The highest lesion contrast in reflectance was measured at wavelengths greater than 1700-nm. Stains interfered significantly at wavelengths shorter than 1150-nm. This study indicates that the optimum wavelengths for reflectance imaging decay in the occlusal surfaces are greater than 1700-nm.

  7. Use of PTFE Stent Grafts for Hemodialysis-related Central Venous Occlusions: Intermediate-Term Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kundu, Sanjoy, E-mail: sanjoy_kundu40@hotmail.com; Modabber, Milad; You, John M.

    2011-10-15

    Purpose: To assess the safety and effectiveness of a polytetrafluoroethylene (PTFE) encapsulated nitinol stents (Bard Peripheral Vascular, Tempe, AZ) for treatment of hemodialysis-related central venous occlusions. Materials and Methods: Study design was a single-center nonrandomized retrospective cohort of patients from May 2004 to August 2009 for a total of 64 months. There were 14 patients (mean age 60 years, range 50-83 years; 13 male, 1 female). All patients had autogenous fistulas. All 14 patients had central venous occlusions and presented with clinical symptoms of the following: extremity swelling (14%, 2 of 14), extremity and face swelling (72%, 10 of 14),more » and face swelling/edema (14%, 2 of 14). There was evidence of access dysfunction with decreased access flow in 36% (5 of 14) patients. There were prior interventions or previous line placement at the site of the central venous lesion in all 14 patients. Results were assessed by recurrence of clinical symptoms and function of the access circuit (National Kidney Foundation recommended criteria). Results: Sixteen consecutive straight stent grafts were implanted in 14 patients. Average treated lesion length was 5.0 cm (range, 0.9-7 cm). All 14 patients had complete central venous occlusion (100% stenosis). The central venous occlusions were located as follows: right subclavian and brachiocephalic vein (21%, 3 of 14), right brachiocephalic vein (36%, 5 of 14), left brachiocephalic vein (36%, 5 of 14), and bilateral brachiocephalic vein (7%, 1 of 14). A total of 16 PTFE stent grafts were placed. Ten- or 12-mm-diameter PTFE stent grafts were placed. The average stent length was 6.1 cm (range, 4-8 cm). Technical (deployment), anatomic (<30% residual stenosis), clinical (resolution of symptoms), and hemodynamic (resolution of access dysfunction) success were 100%. At 3, 6, and 9 months, primary patency of the treated area and access circuit were 100% (14 of 14). Conclusions: This PTFE encapsulated stent

  8. Fluid to fluid contact heat exchanger

    NASA Technical Reports Server (NTRS)

    Clark, W. E.

    1986-01-01

    Heat transfer and pressure drop test results for a fluid to fluid contact heat exchanger are reported. The heat exchanger, fabricated and tested to demonstrate one method of transferring heat between structures in space, had a total contact area of 0.18 sq m. It utilized contact surfaces which were flexible and conformed to the mating contact surfaces upon pressurization of the fluid circulating within the heat exchanger. During proof-of-concept performance tests, the heat exchanger was operated in a typical earth environment. It demonstrated a contact conductance of 3.8 kW/sq m C at contact pressures in the 15 to 70 kPa range.

  9. The role of polymorphisms associated with early tooth eruption in dental and occlusal traits in East Asian populations

    PubMed Central

    Kawaguchi, Akira; Kim, Yong-Il; Haga, Shugo; Katayama, Koshu; Ishida, Hajime; Park, Soo-Byung; Maki, Koutaro; Kimura, Ryosuke

    2014-01-01

    Objective A recent study suggested that rs6504340, a polymorphism within the homeobox B (HOXB) gene cluster, is associated with the susceptibility for malocclusions in Europeans. The resulting malocclusions require orthodontic treatment. The aim of this study was to investigate the association of rs6504340 and other dentition-implicated polymorphisms with dental and occlusal traits in Korean and Japanese populations. Methods The study participants included 223 unrelated Koreans from the Busan area and 256 unrelated Japanese individuals from the Tokyo metropolitan area. DNA samples were extracted from saliva specimens. Genotyping for rs6504340 and four single nucleotide polymorphisms (SNPs) that have been shown to be associated with the timing of first tooth eruption and the number of teeth at 1 year of age (rs10506525, rs1956529, rs9674544, and rs8079702) was performed using TaqMan assays. The Index of Orthodontic Treatment Need (IOTN), overjet, overbite, arch length discrepancy, crown sizes, and length and width of the dental arches were measured. Spearman's correlation coefficients were calculated to evaluate relationships between rs6504340 and these dental/occlusal traits. Results We evaluated the aesthetic components and dental health components of the IOTN in the Korean and Japanese populations and found that neither rs6504340 nor the other four SNPs showed any association with dental and occlusal traits in these East Asian populations. Conclusions These negative results suggest that further research is needed to identify the genetic determinants of malocclusions in order to reach a consensus. PMID:24696826

  10. In vitro evaluation of ICDAS and radiographic examination of occlusal surfaces and their association with treatment decisions.

    PubMed

    Diniz, Michele B; Lima, Luciana Monti; Eckert, George; Zandona, Andrea G Ferreira; Cordeiro, Rita C L; Pinto, Lourdes Santos

    2011-01-01

    This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10× occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0–6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and interexaminer repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was

  11. Influence of occlusal plane inclination and mandibular deviation on esthetics

    PubMed Central

    Corte, Cristiane Cherobini Dalla; da Silveira, Bruno Lopes; Marquezan, Mariana

    2015-01-01

    Objective: The aim of this study was to assess the degree of perception of occlusal plane inclination and mandibular deviation in facial esthetics, assessed by laypeople, dentists and orthodontists. Methods: A woman with 5.88° of inclination and 5.54 mm of mandibular deviation was selected and, based on her original photograph, four new images were created correcting the deviations and creating more symmetric faces and smiles. Examiners assessed the images by means of a questionnaire. Their opinions were compared by qualitative and quantitative analyses. Results: A total of 45 laypeople, 27 dentists and 31 orthodontists filled out the questionnaires. All groups were able to perceive the asymmetry; however, orthodontists were more sensitive, identifying asymmetries as from 4.32° of occlusal plane inclination and 4.155 mm of mandibular deviation (p< 0.05). The other categories of evaluators identified asymmetries and assigned significantly lower grades, starting from 5.88° of occlusal plane inclination and 5.54 mm of mandibular deviation (p< 0.05). Conclusion: Occlusal plane inclination and mandibular deviation were perceived by all groups, but orthodontists presented higher perception of deviations. PMID:26560821

  12. Branch retinal arterial occlusion.

    PubMed

    Subedi, S; Shrestha, C

    2010-01-01

    Retinal arterial occlusion is an ocular emergency in which visual prognosis is poor mostly due to late presentation of the patient and macular involvement. The casee described, in this report is ane incidence of Branch Retinal Arterial Occlusion in a 22 year old female with grade II Mitral Regurgitation. The patiente presented witha complaint of painless, diminution of vision in the right eyn. She also presented with perception of black shadow in the superior visual fiel n of the same eye5 for five days. There was no significant systemic ord personal history. Her visual acuity at presentation was 6/60 and 6/6 in the right and left eyes,y which did not improve with glasses or pin-hole. Anterior segment including papillary reaction was normal in both eyes while Fundus examination of the right eye revealed retinal whitening inside the inferotemporal vascular arcade that was encroaching foveolar avascular zone. Visual field defect was detected at superonasally inside arhade but Fundus Fluorescence Angiography was normal. An echoycardiograph revealed grade II Mitral Regurgitation. The patient was kept on observation and after two2 days of follow-up, vision in the right eye was improved to 6/6 unaided but visual field defect was remained same.

  13. Investigation of the Mixing Behavior and the Generation of Contact-Area in a Continuous Twin-Shaft Kneader

    NASA Astrophysics Data System (ADS)

    Seck, Oliver; Maxisch, Tobias; Bothe, Dieter; Warnecke, Hans-Joachim

    2010-03-01

    The technical synthesis and processing of polymer materials is the basis for major branches of the chemical industry. Well introduced for high-viscosity processes are screw extruders. However, in case of large residence times, a kneader with its large volume is more appropriate, but the latter still requires further understanding for intensification purposes. First, the axial mixing behavior is characterized by studying the residence time distribution under continuous operation. For this purpose silicone oil of high viscosity is used as kneading material. At the inlet dye tracer is injected and detected at the outlet via photometry. The response functions show that the classical dispersion model leads to an appropriate description of the experimental data. By means of a fast chemical reaction of second order the radial mixing behavior including transport on the molecular scale is studied. The generation of contact-area between two fluid elements, each one charged with one of the educts is the characteristic quantity since the two reactants cannot coexist and, hence, react directly at the interface. Thus the amount of detected product is a measure for the contact-area produced by kneading. Based on these data, a simplified model for the mixing process in the kneader is developed.

  14. The Basilar Artery on Computed Tomography Angiography Prognostic Score for Basilar Artery Occlusion.

    PubMed

    Alemseged, Fana; Shah, Darshan G; Diomedi, Marina; Sallustio, Fabrizio; Bivard, Andrew; Sharma, Gagan; Mitchell, Peter J; Dowling, Richard J; Bush, Steven; Yan, Bernard; Caltagirone, Carlo; Floris, Roberto; Parsons, Mark W; Levi, Christopher R; Davis, Stephen M; Campbell, Bruce C V

    2017-03-01

    Basilar artery occlusion is associated with high risk of disability and mortality. This study aimed to assess the prognostic value of a new radiological score: the Basilar Artery on Computed Tomography Angiography (BATMAN) score. A retrospective analysis of consecutive stroke patients with basilar artery occlusion diagnosed on computed tomographic angiography was performed. BATMAN score is a 10-point computed tomographic angiography-based grading system which incorporates thrombus burden and the presence of collaterals. Reliability was assessed with intraclass coefficient correlation. Good outcome was defined as modified Rankin Scale score of ≤3 at 3 months and successful reperfusion as thrombolysis in cerebral infarction 2b-3. BATMAN score was externally validated and compared with the Posterior Circulation Collateral score. The derivation cohort included 83 patients with 41 in the validation cohort. In receiver operating characteristic (ROC) analysis, BATMAN score had an area under receiver operating characteristic curve of 0.81 (95% confidence interval [CI], 0.7-0.9) in derivation cohort and an area under receiver operating characteristic curve of 0.74 (95% CI, 0.6-0.9) in validation cohort. In logistic regression adjusted for age and clinical severity, BATMAN score of <7 was associated with poor outcome in derivation cohort (odds ratio, 5.5; 95% CI, 1.4-21; P =0.01), in validation cohort (odds ratio, 6.9; 95% CI, 1.4-33; P =0.01), and in endovascular patients, after adjustment for recanalization and time to treatment (odds ratio, 4.8; 95% CI, 1.2-18; P =0.01). BATMAN score of <7 was not associated with recanalization. Interrater agreement was substantial (intraclass coefficient correlation, 0.85; 95% CI, 0.8-0.9). BATMAN score had greater accuracy compared with Posterior Circulation Collateral score ( P =0.04). The addition of collateral quality to clot burden in BATMAN score seems to improve prognostic accuracy in basilar artery occlusion patients. © 2017

  15. Acute Central Retinal Vein Occlusion Secondary to Reactive Thrombocytosis after Splenectomy

    PubMed Central

    Oncel Acir, Nursen; Borazan, Mehmet

    2014-01-01

    The diagnosis and treatment of central retinal vein occlusion was reported in a young patient. Central retinal vein occlusion was probably related to secondary to reactive thrombocytosis after splenectomy. The patient was treated with steroids for papilledema and administered coumadin and aspirin. The symptoms resolved, and the findings returned to normal within three weeks. Current paper emphasizes that, besides other well-known thrombotic events, reactive thrombocytosis after splenectomy may cause central retinal vein occlusion, which may be the principal symptom of this risky complication. Thus, it can be concluded that followup for thrombocytosis and antithrombotic treatment, when necessary, are essential for these cases. PMID:25276452

  16. Effect of theobromine-containing toothpaste on dentin tubule occlusion in situ.

    PubMed

    Amaechi, Bennett T; Mathews, Sapna M; Mensinkai, Poornima K

    2015-01-01

    Dentin hypersensitivity (DH) is treated by either occlusion of dentin tubules or nerve desensitization. This in situ study compared dentin tubules occlusion by theobromine-containing dentifrices with (Theodent-classic-F®, TCF) and without (Theodent-classic®, TC) fluoride with 1,500 ppm fluoride toothpaste, Colgate®-Regular (Fluoride) and Novamin®-containing toothpaste, Sensodyne®-5000-Nupro (Novamin®). Each subject wore four intraoral appliances bearing dentin blocks while using one of four test dentifrices (n = 20/dentifrice) twice daily for 7 days. The four appliances were removed successively after 1, 2, 3, and 7 days. Treated blocks and their control (untreated) blocks were examined with scanning electron microscopy (SEM). Effects were compared statistically (ANOVA/Tukey's) based on percentage of surface area covered by deposited precipitate layer (%DPL) and percentage of fully open (%FOT), partially occluded (%POT), and completely occluded (%COT) tubules in each block calculated relative to the number of tubules in their control blocks. SEM observation indicated an increased %COT and %DPL over time. After 1 and 2 days, %COT was comparable with TC and TCF, and significantly (p < 0.05) higher compared with Novamin® and Fluoride. Following 3 and 7 days, %COT was comparable among TC, TCF, and Novamin®, but remained significantly lower in Fluoride. At any time, %DPL was significantly (p < 0.05) higher in TC, TCF, and Novamin® compared with Fluoride. Theobromine-containing toothpastes with and without fluoride have equal potential in occluding dentin tubules within a shorter time period than Novamin®-containing toothpaste; however, the three demonstrated equal potential after 1 week, but not the fluoride toothpaste. Theobromine-containing toothpaste promoted dentin tubule occlusion thus shows potential to relief DH.

  17. Implicit Multibody Penalty-BasedDistributed Contact.

    PubMed

    Xu, Hongyi; Zhao, Yili; Barbic, Jernej

    2014-09-01

    The penalty method is a simple and popular approach to resolving contact in computer graphics and robotics. Penalty-based contact, however, suffers from stability problems due to the highly variable and unpredictable net stiffness, and this is particularly pronounced in simulations with time-varying distributed geometrically complex contact. We employ semi-implicit integration, exact analytical contact gradients, symbolic Gaussian elimination and a SVD solver to simulate stable penalty-based frictional contact with large, time-varying contact areas, involving many rigid objects and articulated rigid objects in complex conforming contact and self-contact. We also derive implicit proportional-derivative control forces for real-time control of articulated structures with loops. We present challenging contact scenarios such as screwing a hexbolt into a hole, bowls stacked in perfectly conforming configurations, and manipulating many objects using actively controlled articulated mechanisms in real time.

  18. Retinal vein occlusion: pathophysiology and treatment options.

    PubMed

    Karia, Niral

    2010-07-30

    This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.

  19. Dissection and re-entry techniques and longer-term outcomes following successful percutaneous coronary intervention of chronic total occlusion.

    PubMed

    Rinfret, Stéphane; Ribeiro, Henrique Barbosa; Nguyen, Can Manh; Nombela-Franco, Luis; Ureña, Marina; Rodés-Cabau, Josep

    2014-11-01

    New techniques involving dissection of the subintimal space and re-entry into the true lumen increase success rates in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). However, their long-term safety and efficacy were unknown. This study included a series of consecutive patients who underwent CTO PCI. All patients who did not present events were contacted 12 to 18 months after their PCI. The combined incidence of cardiac death, myocardial infarction, ischemia-driven target-vessel revascularization (TVR), or reocclusion was assessed as our primary outcome. From January 2010 to January 2013, of 212 CTOs treated in our CTO program, 192 (91%) were successfully opened (in 179 patients). Follow-up data were available for 187 CTOs (97.4%), with 82 (44%) that were opened with dissection re-entry and 105 (56%) with conventional wire escalation techniques. At a median follow-up of 398 days, the primary outcome occurred in 18 of 179 CTOs treated (10.7%), driven by TVR. No patient died from cardiac causes. Eleven CTOs (15.2%) treated with dissection re-entry versus 7 CTOs (7.3%) treated with wire escalation presented with the primary outcome (p = 0.17). With multivariate adjustment, dissection re-entry techniques had no significant impact on outcomes. However, treatment of an in-stent occlusion was independently associated with TVR (hazards ratio >6.0, p <0.001). In conclusion, dissection re-entry techniques have minimal impact on long-term outcomes after CTO PCI, which are favorable in most patients. However, treatment of an in-stent occlusion and use of sirolimus-eluting stent were predictors of subsequent adverse outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. A double blind randomized clinical trial comparing lingualized and fully bilateral balanced posterior occlusion for conventional complete dentures.

    PubMed

    Kawai, Yasuhiko; Ikeguchi, Nobuyuki; Suzuki, Asako; Kuwashima, Azusa; Sakamoto, Ryuji; Matsumaru, Yuichi; Kimoto, Suguru; Iijima, Morio; Feine, Jocelyne Sylvia

    2017-04-01

    A lingualized occlusion (LO) for complete dentures reduces lateral inferences and occlusal force contacts and direction; thus, LO is theorized to be more suitable for patients with compromised ridges than fully bilateral balanced articulation (FBBA). However, no studies have yet provided evidence to support LO in edentate patients with compromised alveolar ridges. The purpose of this study was to compare LO and FBBA in edentulous individuals with compromised ridges. Sixty edentulous individuals were randomly allocated into groups and received dentures with either LO or FBBA. Following delivery, several denture-related satisfaction variables were measured using 100mm visual analogue scales; oral health-related quality of life (OHRQoL) was also assessed using the Oral Health Impact Profile (OHIP). Sub-group analyses of the effect of moderate and severe mandibular bone loss were also carried out. No significant differences were detected between LO and FBBA with the primary outcome. At 6 months, participants with severely atrophied mandibles and FBBA rated their satisfaction with retention of mandibular dentures significantly lower than those with LO (median LO: 86, FBBA: 58.5, p=0.03). They also had significantly lower OHRQoL for the domain of Pain (median LO: 4, FBBA: 5, p=0.02). General satisfaction and total OHIP scores significantly improved between baseline and 6 months only for the LO subjects with severely atrophied mandibles (satisfaction: p=0.003, OHIP total score: p=0.0007). The results indicate that the LO occlusal scheme with hard resin artificial teeth is more efficient for patients with severely resorbed mandibular ridges. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. [Retrospective analysis of patients with thrombocytopenia after patent ductus arteriosus interventional occlusion].

    PubMed

    Liao, Qi-wei; Zhang, Wei-hua; Guang, Xue-feng; Lu, Yi-bing

    2013-03-01

    To explore the risk factors of patent ductus arteriosus (PDA) patients with thrombocytopenia after PDA interventional occlusion. Thrombocytopenia occurred in 14 out of 350 patients underwent PDA occlusion. Age, gender, body weight, PDA size, occluder size, mean pulmonary arterial pressure, the dose of heparin, the manufacturer of occluder, residual shunt after operation were analyzed. The recovery time of different grades of thrombocytopenia was observed. Multivariate logistic regression showed that the PDA size (OR = 2.238, P < 0.05), the dose of heparin (OR = 3.247, P < 0.05), residual shunt after operation (OR = 1.912, P < 0.01) were the independent risk factors of thrombocytopenia after PDA occlusion. The recovery time of mild thrombocytopenia was (7 ± 2) days without treatment. The recovery time of moderate thrombocytopenia was (12 ± 4) days with glucocorticoids treatment. The recovery time of severe thrombocytopenia was (21 ± 7) days with platelet transfusion. The occluder size, dose of heparin, residual shunt are the independent risk factors of thrombocytopenia after PDA interventional occlusion. Recover time of thrombocytopenia after PDA interventional occlusion is closely related to the severity of thrombocytopenia.

  2. Influence of stabilization occlusal splint on craniocervical relationships. Part I: Cephalometric analysis.

    PubMed

    Moya, H; Miralles, R; Zuñiga, C; Carvajal, R; Rocabado, M; Santander, H

    1994-01-01

    This study was conducted in order to determine the effect of an occlusal splint on craniocervical relationships, in subjects with muscle spasms in the sternocleidomastoid and trapezius muscles. A full-arch maxillary stabilization occlusal splint was made for each of the 15 subjects. Two lateral craniocervical radiographs were taken for each subject, with and without an occlusal splint. Cephalometric analysis showed that the splint caused a significant extension of the head on the cervical spine. There was also a significant decrease in the cervical spine lordosis in the first, second and third cervical segment. These cervical changes could be a compensation mechanism caused by the extension of the cranium on the upper cervical spine. The change in the curvature implies that it is necessary to periodically evaluate the changes occurring in the craniocervical relationships after the occlusal splint has been inserted.

  3. RANKL, Osteopontin, and Osteoclast Homeostasis in a Hyper-Occlusion Mouse Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Cameron G.; Ito, Yoshihiro; Dangaria, Smit

    2010-11-15

    The biological mechanisms that maintain the position of teeth in their sockets establish a dynamic equilibrium between bone resorption and apposition. In order to reveal some of the dynamics involved in the tissue responses towards occlusal forces on periodontal ligament (PDL) and alveolar bone homeostasis, we developed the first mouse model of hyperocclusion. Swiss-Webster mice were kept in hyperocclusion for 0, 3, 6, and 9 d. Morphological and histological changes in the periodontium were assessed using micro-computed tomography (micro-CT) and ground sections with fluorescent detection of vital dye labels. Sections were stained for tartrate-resistant acid phosphatase, and the expression ofmore » receptor activator of nuclear factor-{kappa}B ligand (RANKL) and osteopontin (OPN) was analyzed by immunohistochemistry and real-time polymerase chain reaction (PCR). Traumatic occlusion resulted in enamel surface abrasion, inhibition of alveolar bone apposition, significant formation of osteoclasts at 3, 6 and 9 d, and upregulation of OPN and RANKL. Data from this study suggest that both OPN and RANKL contribute to the stimulation of bone resorption in the hyperocclusive state. In addition, we propose that the inhibition of alveolar bone apposition by occlusal forces is an important mechanism for the control of occlusal height that might work in synergy with RANKL-induced bone resorption to maintain normal occlusion.« less

  4. Posttraumatic cerebral infarction due to progressive occlusion of the internal carotid artery after minor head injury in childhood: a case report.

    PubMed

    Matsumoto, Hiroaki; Kohno, Kanehisa

    2011-07-01

    Although minor head injury in childhood is a common occurrence and usually no complications, posttraumatic cerebral infarction has rarely been reported. Such infarction is characterized by occlusion of the lateral lenticulostriate artery. The authors report an atypical case of posttraumatic occlusion of the internal carotid artery (ICA) after minor head injury in childhood. A healthy 16-year-old boy was hit on the head by a pitch while playing baseball. He developed a transient ischemic attack involving the left extremities 15 min after the accident. Initial magnetic resonance imaging revealed neither hemorrhage nor infarction, and MR angiography demonstrated mild stenosis of the right carotid fork. Conservative therapy was started. However, 24 h after the accident, he suddenly developed left hemiparesis. Emergent neuroimaging demonstrated progressive occlusion of the supraclinoid portion of the right ICA and cerebral infarction of the deep white matter in the right frontal lobe. The hemiparesis deteriorated and the infarction area continued to expand on a daily. The patient underwent emergent superficial temporally artery-middle cerebral artery (STA-MCA) bypass. Intraoperative observation demonstrated that the supraclinoid portion of the right ICA was not thrombosed but pale with low tension and did not appear dissected. He fully recovered by 2 weeks after the operation. Postoperative investigations showed gradual improvement of the ICA occlusion. Minor head injury can cause cerebral infarction in childhood, although this is rare. If conservative therapy cannot prevent progressive cerebral infarction, STA-MCA bypass should be considered in case of the ICA occlusion.

  5. Influence of dental occlusion on postural control and plantar pressure distribution.

    PubMed

    Scharnweber, Benjamin; Adjami, Frederic; Schuster, Gabriele; Kopp, Stefan; Natrup, Jörg; Erbe, Christina; Ohlendorf, Daniela

    2017-11-01

    The number of studies investigating correlations between the temporomandibular system and body posture, postural control or plantar pressure distribution is continuously increasing. If a connection can be found, it is often of minor influence or for only a single parameter. However, small subject groups are critical. This study was conducted to define correlations between dental parameters, postural control and plantar pressure distribution in healthy males. In this study, 87 male subjects with an average age of 25.23 ± 3.5 years (ranging from 18 to 35 years) were examined. Dental casts of the subjects were analyzed. Postural control and plantar pressure distribution were recorded by a force platform. Possible orthodontic and orthopedic factors of influence were determined by either an anamnesis or a questionnaire. All tests performed were randomized and repeated three times each for intercuspal position (ICP) and blocked occlusion (BO). For a statistical analysis of the results, non-parametric tests (Wilcoxon-Matched-Pairs-Test, Kruskall-Wallis-Test) were used. A revision of the results via Bonferroni-Holm correction was considered. ICP increases body sway in the frontal (p ≤ 0.01) and sagittal planes (p ≤ 0.03) compared to BO, whereas all other 29 correlations were independent of the occlusion position. For both of the ICP or BO cases, Angle-class, midline-displacement, crossbite, or orthodontic therapy were found to have no influence on postural control or plantar pressure distribution (p > 0.05). However, the contact time of the left foot decreased (p ≤ 0.001) while detecting the plantar pressure distribution in each position. Persistent dental parameters have no effect on postural sway. In addition, postural control and plantar pressure distribution have been found to be independent postural criteria.

  6. Genetics Home Reference: pulmonary veno-occlusive disease

    MedlinePlus

    ... G, Humbert M. Pulmonary veno-occlusive disease: clinical, functional, radiologic, and hemodynamic characteristics and outcome of 24 cases confirmed by histology. Medicine (Baltimore). 2008 Jul;87(4):220-33. doi: ...

  7. Minimally invasive per-catheter occlusion and dilation procedures for congenital cardiovascular abnormalities in dogs.

    PubMed

    Tobias, Anthony H; Stauthammer, Christopher D

    2010-07-01

    With ever-increasing sophistication of veterinary cardiology, minimally invasive per-catheter occlusion and dilation procedures for the treatment of various congenital cardiovascular abnormalities in dogs have become not only available, but mainstream. Much new information about minimally invasive per-catheter patent ductus arteriosus occlusion has been published and presented during the past few years. Consequently, patent ductus arteriosus occlusion is the primary focus of this article. Occlusion of other less common congenital cardiac defects is also briefly reviewed. Balloon dilation of pulmonic stenosis, as well as other congenital obstructive cardiovascular abnormalities is discussed in the latter part of the article.

  8. Occlusal Classification in Relation to Original Cleft Width in Patients With Unilateral Cleft Lip and Palate.

    PubMed

    Huang, Andrew H; Patel, Kamlesh B; Maschhoff, Clayton W; Huebener, Donald V; Skolnick, Gary B; Naidoo, Sybill D; Woo, Albert S

    2015-09-01

    To determine a correlation between the width of the cleft palate measured at the time of lip adhesion, definitive lip repair, and palatoplasty and the subsequent occlusal classification of patients born with unilateral cleft lip and palate. Retrospective, observational study. Referral, urban, children's hospital Participants : Dental models and records of 270 patients were analyzed. None. Angle occlusion classification. The mean age at which occlusal classification was determined was 11 ± 0.3 years. Of the children studies, 84 were diagnosed with Class I or II occlusion, 67 were diagnosed with Class III occlusion, and 119 were lost to follow up or transferred care. Mean cleft widths were significantly larger in subjects with Class III occlusion for all measures at time of lip adhesion and definitive lip repair (P < .02). At time of palatoplasty, cleft widths were significantly greater at the alveolus (P = .025) but not at the midportion of the hard palate (P = .35) or posterior hard palate (P = .10). Cleft widths from the lip through to the posterior hard palate are generally greater in children who are diagnosed with Class III occlusion later in life. Notably, the alveolar cleft width is significantly greater at each time point for patients who went on to develop Class III occlusion. There were no significant differences in cleft widths between patients diagnosed later with Class I and Class II occlusions.

  9. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

    PubMed

    Abay, T Y; Kyriacou, P A

    2016-04-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.

  10. Retinal vein occlusion: pathophysiology and treatment options

    PubMed Central

    Karia, Niral

    2010-01-01

    This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms. PMID:20689798

  11. Near-IR and CP-OCT Imaging of Suspected Occlusal Caries Lesions

    PubMed Central

    Simon, Jacob C.; Kang, Hobin; Staninec, Michal; Jang, Andrew T.; Chan, Kenneth H.; Darling, Cynthia L.; Lee, Robert C.; Fried, Daniel

    2017-01-01

    Introduction Radiographic methods have poor sensitivity for occlusal lesions and by the time the lesions are radiolucent they have typically progressed deep into the dentin. New more sensitive imaging methods are needed to detect occlusal lesions. In this study, cross-polarization optical coherence tomography (CP-OCT) and near-IR imaging were used to image questionable occlusal lesions (QOC's) that were not visible on radiographs but had been scheduled for restoration on 30 test subjects. Methods Near-IR reflectance and transillumination probes incorporating a high definition InGaAs camera and near-IR broadband light sources were used to acquire images of the lesions before restoration. The reflectance probe utilized cross-polarization and operated at wavelengths from 1500–1700-nm where there is an increase in water absorption for higher contrast. The transillumination probe was operated at 1300-nm where the transparency of enamel is highest. Tomographic images (6×6×7 mm3) of the lesions were acquired using a high-speed swept-source CP-OCT system operating at 1300-nm before and after removal of the suspected lesion. Results Near-IR reflectance imaging at 1500–1700-nm yielded significantly higher contrast (p<0.05) of the demineralization in the occlusal grooves compared with visible reflectance imaging. Stains in the occlusal grooves greatly reduced the lesion contrast in the visible range yielding negative values. Only half of the 26 lesions analyzed showed the characteristic surface demineralization and increased reflectivity below the dentinal-enamel junction (DEJ) in 3D OCT images indicative of penetration of the lesion into the dentin. Conclusion This study demonstrates that near-IR imaging methods have great potential for improving the early diagnosis of occlusal lesions. PMID:28339115

  12. Bite force measurement system using pressure-sensitive sheet and silicone impression material.

    PubMed

    Ando, Katsuya; Fuwa, Yuji; Kurosawa, Masahiro; Kondo, Takamasa; Goto, Shigemi

    2009-03-01

    This study was conducted to reduce the bias in measured values caused by the thickness of materials used in occlusal examinations. To this end, a silicone impression material for bite force measurement and an experimental model of a simplified stomatognathic system were employed in this study. By means of this experimental model, results showed that the effect of bias toward the posterior arch could be reduced in the anterior-posterior distribution of bite forces and in the occlusal contact areas due to the thickness of the materials used in occlusal examinations.

  13. Numerical Simulation of Thrombotic Occlusion in Tortuous Arterioles

    PubMed Central

    Feng, Zhi-Gang; Cortina, Miguel; Chesnutt, Jennifer KW; Han, Hai-Chao

    2017-01-01

    Tortuous microvessels alter blood flow and stimulate thrombosis but the physical mechanisms are poorly understood. Both tortuous microvessels and abnormally large platelets are seen in diabetic patients. Thus, the objective of this study was to determine the physical effects of arteriole tortuosity and platelet size on the microscale processes of thrombotic occlusion in microvessels. A new lattice-Boltzmann method-based discrete element model was developed to simulate the fluid flow field with fluid-platelet coupling, platelet interactions, thrombus formation, and thrombotic occlusion in tortuous arterioles. Our results show that vessel tortuosity creates high shear stress zones that activate platelets and stimulate thrombus formation. The growth rate depends on the level of tortuosity and the pressure and flow boundary conditions. Once thrombi began to form, platelet collisions with thrombi and subsequent activations were more important than tortuosity level. Thrombus growth narrowed the channel and reduced the flow rate. Larger platelet size leads to quicker decrease of flow rate due to larger thrombi that occluded the arteriole. This study elucidated the important roles that tortuosity and platelet size play in thrombus formation and occlusion in arterioles. PMID:29327739

  14. Measurement of periapical pressure created by occlusal loading.

    PubMed

    Dobó-Nagy, C; Fejérdy, P; Angyal, J; Harasztosi, L; Daróczi, L; Beke, D; Wesselink, P R

    2003-10-01

    To develop an in vitro model in which the pressure in the periapical tissues can be measured during loading. Extracted human maxillary central incisors were embedded in resin blocks that had physical characteristics similar to those of bone and periodontal ligament. Each tooth was loaded with 20, 40, 50, 60, 75, 85, 100, 200, 300 and 450 N vertical forces from the incisal edge of the crown on three consecutive occasions. A minute resistor embedded in the periapical space was used to detect apical pressure changes during occlusal loading. The ratio of apical pressure changes (DeltaP) to the loading force changes (DeltaF) was calculated. The periapical pressure detected was in direct proportion to the loading force. The mean value of DeltaP/DeltaF was 5.994 kPa N-1 (SD = 2.04). Direct proportionality was found between the coronal loading and the apical hydrostatic pressure. The DeltaP/DeltaF ratio determined in this study makes it easier to estimate the apical hydrostatic pressure values during occlusal loading of single-rooted teeth. In this study, the apical pressure generated under occlusal loading was the same magnitude as that estimated with the finite element method.

  15. The effect of resting blood flow occlusion on exercise tolerance and W'.

    PubMed

    Broxterman, Ryan M; Craig, Jesse C; Ade, Carl J; Wilcox, Samuel L; Barstow, Thomas J

    2015-09-15

    It has previously been postulated that the anaerobic work capacity (W') may be utilized during resting blood flow occlusion in the absence of mechanical work. We tested the hypothesis that W' would not be utilized during an initial range of time following the onset of resting blood flow occlusion, after which W' would be utilized progressively more. Seven men completed blood flow occlusion constant power severe intensity handgrip exercise to task failure following 0, 300, 600, 900, and 1,200 s of resting blood flow occlusion. The work performed above critical power (CP) was not significantly different between the 0-, 300-, and 600-s conditions and was not significantly different from the total W' available. Significantly less work was performed above CP during the 1,200-s condition than the 900-s condition (P < 0.05), while both conditions were significantly less than the 0-, 300-, and 600-s conditions (P < 0.05). The work performed above CP during these conditions was significantly less than the total W' available (P < 0.05). The utilization of W' during resting blood flow occlusion did not begin until 751 ± 118 s, after which time W' was progressively utilized. The current findings demonstrate that W' is not utilized during the initial ∼751 s of resting blood flow occlusion, but is progressively utilized thereafter, despite no mechanical work being performed. Thus, the utilization of W' is not exclusive to exercise, and a constant amount of work that can be performed above CP is not the determining mechanism of W'. Copyright © 2015 the American Physiological Society.

  16. Voxel-Space Ambient Occlusion

    DTIC Science & Technology

    2012-02-01

    a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. a...represents the BRDF of the surface material, for incoming direction ψ and an outgoing direction. L(y) is the incoming radiance in the direction ψ from a...10-1-0338). Models come from the Stanford repository. References [BS09] L. Bavoil, M.Sainz Multi-layer dual-resolution screen-space ambient occlusion

  17. Secondary trauma from occlusion: three-dimensional analysis using the finite element method.

    PubMed

    Geramy, Allahyar; Faghihi, Sharieh

    2004-01-01

    Clinical effects of forces applied by dental occlusion on the periodontium have been evaluated for decades. Historically, trauma from occlusion has been considered as a major etiologic factor of inflammatory periodontal diseases, while some researchers have interpreted it to be of less importance or without any detectable importance in periodontics. In this study, five three-dimensional models of a maxillary central incisor were created using ANSYS 5.40. The only difference in each model was the height of the alveolar bone that showed from normal height (13 mm of alveolar bone height) to 8 mm of alveolar bone loss (5 mm of alveolar bone height). Five-point forces of 0.3 N summing up to 1.5 N were applied in a parallel line, 1 mm apical to the incisal edge on the palatal side in a palatolabial direction. The maximum (S1) and minimum (S3) principal stresses in the nodes of the labial side of the periodontal ligament (apical to the alveolar crest) were assessed. Analysis was done using the finite element method. An increase of S1 (up to 16 times in the cervical and 11.25 times in the apical area) and S3 (up to 17.13 times in the cervical and 9.9 times in the apical area) in comparison to the normal model was shown. The highest stress levels were traced in the subcervical area, except for the last model (8 mm of the alveolar bone loss). According to the results of this study, 2.5 mm of alveolar bone loss can be considered as a limit beyond which stress alterations were accelerated. Based on the FEM analysis, alveolar bone loss increases stress (S1 and S3) produced in the PDL, in spite of applying the same force vector.

  18. Effects of retraction force and anchorage reinforcement on occlusal force: a model study.

    PubMed

    Kim, MoonHee; Seol, Kyung-sim; Lee, Yoonjung; Park, Jiman; Kim, Minji; Chun, Youn-Sic

    2014-10-01

    The aim of this study was to investigate the effects of retraction force and anchorage reinforcement with orthodontic mini implants on occlusal force. A strain gauge was attached to the palatal surface of the maxillary right first molar on an en masse retraction model. Occlusal forces were measured from this model, according to different retraction forces that were generated by elastic chain, under varied compressive forces (simulating masticatory forces). This retraction experiment was then performed again, after using anchorage reinforcement with an orthodontic mini implant. Occlusal force decreased as retraction force increased. The decrease showed a significant difference above 150g of retraction force (P < 0.05) and was more definite under compressive force higher than 150 N (P < 0.001). After anchorage reinforcement with the orthodontic mini implant, however, occlusal force did not significantly decrease with increasing retraction force. Significant differences in occlusal force were noted between the conditions with and without anchorage reinforcement when the applied retraction force was greater than 200g. Occlusal force tends to decrease during retraction, and this decrease can be prevented by anchorage reinforcement with orthodontic mini implants. Further investigation on the actual masticatory process in humans is required for more clear clinical implication. © The Author 2013. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  19. Central retinal artery occlusion in an ANCA negative Churg-Strauss syndrome patient.

    PubMed

    Türkçüoğlu, Peykan; Isik, Ahmet; Deniz, Nurettin; Turgut, Burak; Kan, Elif Kiliç

    2007-12-01

    To describe a central retinal artery occlusion in a patient with antineutrophil cytoplasmic antibody (ANCA) negative Churg-Strauss syndrome. Review of clinical and laboratory findings of a 44-year-old woman with ANCA negative Churg-Strauss syndrome that developed sudden vision loss in left eye. Left central retinal artery occlusion was diagnosed by retinal whitening, a cherry-red spot, and delayed arterial filling on fluorescein angiography. Perinuclear ANCA and cytoplasmic ANCA were negative. Central retinal artery occlusion can occur in ANCA negative Churg-Strauss syndrome. Patients with this diagnosis should be considered for prophylactic high dose corticosteroid, regardless of their ANCA status.

  20. Occlusion therapy of unilateral amblyopia with botulinum toxin induced ptosis.

    PubMed

    Halkiadakis, Ioannis; Iliaki, Olga; Kalyvianaki, Maria I; Tsilimbaris, Miltiadis K

    2007-01-01

    In order to evaluate the role of botulinum toxin induced ptosis as an occlusion method to treat unilateral deep strabismic amblyopia in two uncooperative children, we injected 0.2 ml of diluted botulinum toxin in the levator palpaebrae; low sedation was necessary in one of the two children. In both cases a marked ptosis was achieved, which lasted about four weeks and then gradually resolved completely. The visual acuity of the ablyopic eye increased in both children, making patching easy thereafter. One child developed amblyopia in the injected eye, which was handled successfully using part-time occlusion. No other side effects were noted. Whether this new method could be a simple, safe and effective alternative method of occlusion for the treatment of deep amblyopia in uncooperative children needs to be proven with a larger series of children.