Sample records for occlusal fissures sealing

  1. The immediate and long-term effects of invasive and noninvasive pit and fissure sealing techniques on the microflora in occlusal fissures of human teeth.

    PubMed

    Kramer, P F; Zelante, F; Simionato, M R

    1993-01-01

    The purpose of this study was to evaluate the effect of acid conditioning and occlusal sealant on microbial colonization of pit and fissures submitted to ameloplasty or left intact. Human enamel blocks containing fissures prepared from the occlusal surfaces of unerupted third molars were implanted in occlusal fillings in molars of 12 patients for seven, 30, 60, and 120 days. After seven days of exposure to the oral environment, the pit and fissure blocks were removed and found to be colonized, mainly with gram-positive coccal flora. The acid-etching procedure itself reduced the number of cultivable microorganisms by about 95%. Subsequent application of occlusal sealant caused a gradual decrease of the remaining viable microorganism throughout the experiment. Despite the decrease of 100% after acid etching in most of the fissures submitted to ameloplasty, the occlusal sealant did not lead to a subsequent significant reduction.

  2. An in vitro investigation of pre-treatment effects before fissure sealing.

    PubMed

    Bagheri, Mahshid; Pilecki, Peter; Sauro, Salvatore; Sherriff, Martyn; Watson, Timothy F; Hosey, Marie Therese

    2017-11-01

    Fissure sealants prevent occlusal caries in permanent molars. Enamel preparation methods are used before fissure sealing. To investigate effects of bioglass air-abrasion pre-treatment with and without an adhesive, on fissure enamel of permanent teeth, with respect to etchability, microleakage and microtensile bond strength. Half of the occlusal surfaces of 50 extracted premolars underwent bioglass air-abrasion. Dye was applied to the entire occlusal surface. Photographs were taken to score etched surface by dye uptake. Adhesive was applied to 25 of the bioglass-treated areas and all teeth were fissure sealed, sectioned, and evaluated using confocal microscopy. Buccal and lingual surfaces of a further eight premolars were acid-etched and randomly received: air-abrasion, adhesive, both, or none before sealant application for microtensile bond strength measurement in half of the samples immediately and half following 6 months of water immersion. Linear mixed models and multinomial logistic regression were used (P = 0.05). Bioglass air-abrasion significantly improved enamel etchability and reduced microleakage. The addition of an adhesive made no difference to either microleakage or microtensile bond strength. The combination of bioglass abrasion and adhesive led to more cohesive, rather than adhesive, failure. Bioglass air-abrasion improved enamel etchability and reduced microleakage irrespective of the adhesive use but neither pre-treatment affected the microtensile bond strength. © 2017 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    PubMed

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p <0.05. There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  4. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel

    PubMed Central

    Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    Background The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. Material and Methods A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p<0.05. Results There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. Conclusions The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words:Pit and fissure sealant, Universal adhesive, Saliva. PMID:29670708

  5. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures.

    PubMed

    Aguilar, F G; Drubi-Filho, B; Casemiro, L A; Watanabe, M G C; Pires-de-Souza, F C P

    2007-01-01

    This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield) and a photochromatic flowable composite resin (Tetric Flow Chroma) placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment--ten premolars were sealed with each material, isolated (except for the sealed surface) and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab). The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove's total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment--30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab). The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days). New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way ANOVA and Tukey's test P<0.05). Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  6. Noninvasive pit and fissure sealing: microtensile bond strength to intact bovine enamel of different pit and fissure sealants in a simplified fissure model.

    PubMed

    Papacchini, Federica; Cury, Alvaro H; Goracci, Cecilia; Chieffi, Nicoletta; Tay, Franklin R; Polimeni, Antonella; Ferrari, Marco

    2006-12-01

    To measure the microtensile bond strength of different pit and fissure sealants in a simplified fissure model. Twenty extracted bovine mandibular permanent incisors were randomly divided into 4 groups for treatment: G1: 35% phosphoric acid/Clinpro Sealant; G2: 35% phosphoric acid/Delton; G3: Non-Rinse Conditioner/Dyract Seal; G4: 20% polyacrylic acid/Fuji IILC. Each tooth was sectioned into 6 pieces (4 x 6 mm) of buccal enamel. SEM examination was used to confirm the presence of aprismatic enamel on each tooth. Using a spacer, two pieces of etched enamel were secured to a glass slide at a mean distance of 0.6+/-0.1 mm. The space between enamel substrates was then etched/conditioned and sealed with different materials according to the tested groups. By serially cutting each double-bonded sample, multiple beam-shaped specimens about 0.8mm(2) in cross section were obtained and tested in tension (0.5 mm/min) until failure occurred at either one of the two stressed interfaces. Failure modes were classified by stereomicroscopy. G1 and G2 showed statistically higher bond strengths than G3 and G4. G4 demonstrated the significantly lowest bond strength. Failures were mostly adhesive in G1, G2, G3, and mainly cohesive/mixed in G4. According to this model, resin-based materials (Clinpro Sealant, Delton) showed better microtensile bond strength than compomer (Dyract Seal) or resin-modified glass ionomer (Fuji IILC).

  7. The effect of pit and fissure sealants on the detection of occlusal caries in vitro.

    PubMed

    Manton, D J; Messer, L B

    2007-03-01

    To compare, in vitro, the effect of placing opaque (OPS) and clear fluorescing (CFS) pit and fissure sealants (PFS) on the detection of occlusal caries (OCD). Occlusal surfaces of 67 extracted molars were examined under standardised conditions by 6 final year undergraduate dental students, using visual, bitewing radiography, transillumination (FOTI), laser fluorescence (LF) and tactile methods of caries detection. The teeth were then assigned randomly to two groups for PFS placement: OPS and CFS; then the OCD methods were repeated. Caries presence/absence was determined histologically on serial sections examined under stereo-microscopy (10x). Before PFS placement the sensitivity and specificity for the OCD methods were: visual: 68%, 71%; radiographic: 15%, 95%; FOTI: 36%, 93%; LF: 49%, 83% and tactile: 39%, 67%, respectively. After placement of OPS, the sensitivity of LF (20%) and visual (13%) methods decreased and specificity increased (93%, 98% respectively). Placement of CFS resulted in minor changes in sensitivity and specificity. Correlation (Spearman's Rho coefficients) between OCD methods and histological intra-dentinal caries for pre- PFS, OPS, and CFS were: visual: 0.38, 0.34, 0.33; FOTI: 0.42, 0.35, 0.43; and LF: 0.41, 0.30, and 0.45 respectively. The sensitivity of all OCD methods was low, as well as their correlation to the histological gold standard. Placing OPS further decreased the sensitivity of LF and visual methods, whereas placing CFS had little effect on all OCD methods. It is recommended that tactile detection of occlusal caries should be discontinued, and the probe used only to clean the pits and fissures gently for more accurate visual detection, or prior to pit and fissure sealant placement. Further research into the development of an affordable, robust, accurate and easy to use method for OCD is required.

  8. Treatment of Angio-Seal-Related Femoral Artery Occlusion Using Directional Atherectomy-Primary Results and Midterm Follow-Up.

    PubMed

    Babaev, Anvar; Gokhale, Rohit; Zavlunova, Susanna; Attubato, Michael

    2016-11-01

    We describe a novel approach for the endovascular treatment of femoral artery occlusion as a result of Angio-Seal closure device deployment. Angio-Seal is the most commonly used vascular closure device following percutaneous coronary and peripheral catheterizations worldwide. A rare complication of Angio-Seal deployment is an occlusion of the femoral artery leading to limb ischemia requiring revascularization. Given its unique ability to cut both atherosclerotic plaque and the Angio-Seal anchor with a collagen plug at operator-directed planes, TurboHawk/HawkOne atherectomy device can be a fast and effective approach to treat Angio-Seal-associated femoral artery occlusions. We studied 13 consecutive patients who developed Angio-Seal-associated femoral artery occlusions that occurred from 3 hours to several weeks after catheterization. These patients were successfully treated with TurboHawk/HawkOne directional atherectomy followed by balloon angioplasty with no complications. During a mean follow-up period of 20.4 ± 17.3 months, 12 patients remained claudication free with no evidence of obstructive arterial disease of the treated segment on imaging studies. One patient developed restenosis that was treated with repeat atherectomy and balloon angioplasty following which he was asymptomatic at follow-up. The use of directional atherectomy followed by balloon angioplasty is a quick, safe, and effective endovascular approach to treating Angio-Seal-associated femoral artery occlusions. It is associated with an excellent success rate, no complications, and good midterm outcomes.

  9. Sealing occlusal caries lesions in adults referred for restorative treatment: 2-3 years of follow-up.

    PubMed

    Bakhshandeh, Azam; Qvist, Vibeke; Ekstrand, Kim R

    2012-04-01

    The aim of this study was to assess the possibility to arrest occlusal caries lesions in adults by sealant as well as to assess the presence of radiographic progression, arrest, and regression of the sealed lesions. Seventy-two occlusal caries lesions in 52 adult patients referred to restorative treatment by senior lecturers at School of Dentistry, Copenhagen, Denmark were included. In case the patient had more than one occlusal caries lesion, randomization between sealing and restoration was made; otherwise, the lesion was sealed. In total, 60 resin sealants and 12 composite restorations were made. Follow-up period was 25-38 months (mean = 33 months). Data were analyzed using non-parametric statistics including kappa statistics. After 2-3 years, the dropout rate was 15%; two patients did not show up for control and nine previously sealed lesions were restored by the patients' general practitioners. All 12 restorations and 39 of the remaining 49 sealants were well functioning, seven (14%) sealants were repaired/replaced due to failure, and three (6%) sealed lesions were restored due to caries progression (p > 0.05). The radiographic assessment showed caries progression beneath five (10%) sealants, caries regression beneath one (2%) sealant, and unchanged depth beneath 43 (88%) sealants and all restorations (p > 0.05). The majority of the referred lesions were successfully arrested by sealants, indicating the possibility for extending the criteria for sealing occlusal caries lesions in adults. However, a longer observation period is needed for final conclusion. Extending the criteria of therapeutic sealing of occlusal caries lesions in adults will lead to increased dental health.

  10. Non-destructive measurement of demineralization and remineralization in the occlusal pits and fissures of extracted 3rd molars with PS-OCT

    NASA Astrophysics Data System (ADS)

    Lee, Chulsung; Hsu, Dennis J.; Le, Michael H.; Darling, Cynthia L.; Fried, Daniel

    2009-02-01

    Previous studies have demonstrated that Polarization Sensitive Optical Coherence Tomography (PS-OCT) can be used to image the remineralization of early artificial caries lesion on smooth enamel surfaces of human and bovine teeth. However, most new dental decay is found in the pits and fissures of the occlusal surfaces of posterior dentition and it is in these high risk areas where the performance of new caries imaging devices need to be investigated. The purpose of this study was to demonstrate that PS-OCT can be used to measure the subsequent remineralization of artificial lesions produced in the pits and fissures of extracted 3rd molars. A PS-OCT system operating at 1310-nm was used to acquire polarization resolved images of occlusal surfaces exposed to a demineralizing solution at pH-4.5 followed by a fluoride containing remineralizing solution at pH-7.0 containing 2-ppm fluoride. The integrated reflectivity was calculated to a depth of 200-µm in the entire lesion area using an automated image processing algorithm. Although a well-defined surface zone was clearly resolved in only a few of the samples that underwent remineralization, the PS-OCT measurements indicated a significant (p<0.05) reduction in the integrated reflectivity between the severity of the lesions that were exposed to the remineralization solution and those that were not. The lesion depth and mineral loss were also measured with polarized light microscopy and transverse microradiography after sectioning the teeth. These results show that PS-OCT can be used to non-destructively monitor the remineralization potential of anti-caries agents in the important pits and fissures of the occlusal surface.

  11. Effect of occlusal calculus utilized as a potential "biological sealant" in special needs patients with gastric feeding tubes: a qualitative in vitro contrast to pit and fissure sealant restorations.

    PubMed

    Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G

    2016-01-01

    The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.

  12. Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): a 4 year clinical study.

    PubMed

    Lygidakis, N A; Dimou, G; Stamataki, E

    2009-12-01

    This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p<0.001). Also both groups revealed a decreasing retention rate over the 4-year period (p<0.001). There was no difference in dental caries increment rate and enamel breakdowns at the end of the study (p>0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.

  13. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    PubMed

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  14. The Effect of Various Finish Line Configurations on the Marginal Seal and Occlusal Discrepancy of Cast Full Crowns After Cementation - An In-vitro Study.

    PubMed

    Nemane, Vaishali; Akulwar, Ravikumar Suryakanth; Meshram, Suresh

    2015-08-01

    The marginal fit of crowns is of clinical importance. It is found that marginal and occlusal discrepancies are commonly increased following cementation. The resistance of cementing materials is a factor that prevents cast restorations from being correctly seated. Different finish lines behave differently in facilitating the escape of the cement. When the escape path of the cement decreases, the crown fails to seat further. This study was planned with an aim to evaluate the effect of various finish lines on the marginal seal and occlusal seat of full crown preparations. Six stainless steel metal dies were machined to simulate molar crown preparations. The diameter was 10 mm and height was 6mm. The occlusal surface was kept flat and a small circular dimple was machined for reorientation of the wax pattern and metal copings, margins of various designs were machined accurately. The margins prepared were Group A- 90(0)C shoulder, Group B- Rounded shoulder, Group C- 45 degree sloped shoulder, Group D- Chamfer, Group E- Long chamfer, Group F- Feather edge. Full cast metal crowns of base metal alloy were fabricated over the metal dies. Zinc phosphate luting cement was used for the cementation. After twenty four hours, the cemented crown and die assembly were embedded in clear acrylic resin so as to hold the assembly together while sectioning. Twenty four hours later, all the samples were sectioned sagitally. The sectioned halves were focused under a stereomicroscope and the cement spaces were measured to the nearest micron. The cement thickness was measured at two points on the occlusal surface and one at each margin. Significant differences were observed in the occlusal seat and marginal seal of all the finish line configurations. The rounded shoulder had the best occlusal seat, followed by 90(0)C shoulder. The occlusal seat and marginal seal afforded by the shoulder finish lines were similar whereas there was a vast difference in the seating and sealing of long chamfer

  15. Systematic review of noninvasive treatments to arrest dentin non-cavitated caries lesions

    PubMed Central

    de Assunção, Isauremi Vieira; da Costa, Giovanna de Fátima Alves; Borges, Boniek Castillo Dutra

    2014-01-01

    AIM: To systematically review the literature on the efficacy of noninvasive methods of arresting the progression of non-cavitated occlusal carious lesions in dentin. METHODS: The Medline/PubMed, LILACS, SciELO and Scopus databases were searched to identify relevant publications through to November 2013. Only clinical trials evaluating the ability of noninvasive methods to arrest the progression of occlusal non-cavitated carious lesions in dentin were included. Screening, data extraction and quality assessment were conducted independently and in duplicate. RESULTS: Of 167 citations identified, nine full text articles were screened and five were included in the analysis. All papers reported on occlusal fissure sealing using a self-curing glass ionomer (n = 1) or resin-based (n = 4) sealant. Only the use of resin-based sealant to obliterate occlusal fissures arrested the progression of non-cavitated occlusal carious lesions in dentin. CONCLUSION: Occlusal fissure sealing with a resin-based sealant may arrest the progression of non-cavitated occlusal dentinal caries. Further clinical trials with longer follow-up times should be performed to increase scientific evidence. PMID:24868513

  16. The Effect of Various Finish Line Configurations on the Marginal Seal and Occlusal Discrepancy of Cast Full Crowns After Cementation - An In-vitro Study

    PubMed Central

    Nemane, Vaishali; Meshram, Suresh

    2015-01-01

    Background The marginal fit of crowns is of clinical importance. It is found that marginal and occlusal discrepancies are commonly increased following cementation. The resistance of cementing materials is a factor that prevents cast restorations from being correctly seated. Different finish lines behave differently in facilitating the escape of the cement. When the escape path of the cement decreases, the crown fails to seat further. Materials and Methods This study was planned with an aim to evaluate the effect of various finish lines on the marginal seal and occlusal seat of full crown preparations. Six stainless steel metal dies were machined to simulate molar crown preparations. The diameter was 10 mm and height was 6mm. The occlusal surface was kept flat and a small circular dimple was machined for reorientation of the wax pattern and metal copings, margins of various designs were machined accurately. The margins prepared were Group A- 900C shoulder, Group B- Rounded shoulder, Group C- 45 degree sloped shoulder, Group D- Chamfer, Group E- Long chamfer, Group F- Feather edge. Full cast metal crowns of base metal alloy were fabricated over the metal dies. Zinc phosphate luting cement was used for the cementation. After twenty four hours, the cemented crown and die assembly were embedded in clear acrylic resin so as to hold the assembly together while sectioning. Twenty four hours later, all the samples were sectioned sagitally. The sectioned halves were focused under a stereomicroscope and the cement spaces were measured to the nearest micron. The cement thickness was measured at two points on the occlusal surface and one at each margin. Results Significant differences were observed in the occlusal seat and marginal seal of all the finish line configurations. The rounded shoulder had the best occlusal seat, followed by 900C shoulder. The occlusal seat and marginal seal afforded by the shoulder finish lines were similar whereas there was a vast difference in the

  17. Evaluation of different types of enamel conditioning before application of a fissure sealant.

    PubMed

    Ciucchi, Philip; Neuhaus, Klaus W; Emerich, Marta; Peutzfeldt, Anne; Lussi, Adrian

    2015-01-01

    The aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.

  18. Effect of air abrasion and polishing on primary molar fissures.

    PubMed

    Lenzi, T L; Menezes, L B R; Soares, F Z M; Rocha, R O

    2013-04-01

    To evaluate the effect of air abrasion and polishing on primary molar fissures under light microscopy. 15 exfoliated primary second molars were longitudinally sectioned and photographed under a stereomicroscope (40×; baseline evaluation). Sections were then randomly allocated into one of the two groups (n = 15) and treated by either air abrasion (aluminium oxide jet) or air polishing (sodium bicarbonate jet) for 30 s. After treatment, sections were washed with an air/water spray, dried with absorbent paper, and photographed as previously described (final evaluation). Baseline and final morphology were compared by two blinded examiners who evaluated changes in the width and depth of fissures. The percentage of changed fissures was analysed, and the two treatments were compared using the Mann-Whitney test (α = 0.01). Both air systems resulted in fissure changes in most (93.3 %) of the sections. No significant differences in fissure width changes were found between treatments, but when changes in fissure depth were evaluated, air polishing was found to be less damaging than air abrasion (p < 0.01). Air abrasion and polishing cause changes to the anatomical configuration of occlusal fissures of primary molars.

  19. Enhancing caries resistance in occlusal fissures with a short-pulsed CO2 9.6-μm laser: an in vitro pH-cycling study, preliminary results

    NASA Astrophysics Data System (ADS)

    Charland, Daniel; Fulton, Crystal; Rechmann, Beate; Hewko, Mark; Featherstone, John; Choo-Smith, Lin-P'ing; Rechmann, Peter

    2011-03-01

    Treatment of occlusal surfaces with a short-pulsed CO2 9.6 μm wavelength laser has previously been proposed as a method for caries prevention. A sample of 20 extracted human molars were measured before and after demineralizationremineralization pH-cycling with ICDAS II visual inspection, DIAGNOdent, quantitative light-induced fluorescence (QLF), SoproLife in daylight and blue light-induced fluorescence mode, optical coherence tomography (OCT) and polarized Raman spectroscopy (PRS). Per tooth, one fissure was subjected to laser treatment using a short-pulsed CO2 laser at 9.6 μm wavelength with a fluence of 3.5 J/cm2, 20 Hz pulse repetition rate, 20 μs pulse duration, angulated handpiece, and focus diameter of 600 μm, while the other fissure was left untreated as control. The teeth were subjected to a demineralization-remineralization pH-cycling for 9 days. Cross-sectional micro-hardness testing was done as a gold standard to compare results with findings from the other detection methods used. Due to the small sample size reported, the trend observed was that laser treated fissures demonstrated a smaller relative mineral loss ▵Z than the controls. QLF findings followed a similar trend. Using a rotary catheter probe, OCT measurements were acquired from the various fissures to generate circularly mapped OCT depth images. PRS measurements of parallel- and cross-polarized spectra were acquired with a Raman microscope system. Preliminary OCT images showed differences in the initial air-tooth interface, with PRS results indicating a change in the surface property along with biochemical alterations after pH-cycling. Following pH-cycling, an increase in the OCT subsurface light backscattering intensity in the control fissures was observed compared to the laser test fissures. Porphyrin based fluorescence methods like DIAGNOdent and SoproLife, respectively demonstrated only additional light scattering due to the demineralization process.

  20. [Comparative studies on fissure sealing: composite versus Cermet cement].

    PubMed

    Hickel, R; Voss, A

    1989-06-01

    Fifty two molars sealed with either composite or Cermet cement were compared. The composite sealant was applied after enamel etching using a rubber dam. Before sealing with Cermet cement the enamel was only cleaned with pumice powder and sodium hypochlorie and the material was applied without enamel etching. After an average follow-up of 1.6 years composite sealants proved to be significantly more reliable. Cermet cement sealings showed defects more frequently.

  1. Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars.

    PubMed

    Sly, Edith G; Kaplan, Andrea E; Missana, Liliana

    2010-01-01

    The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A double-blind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge's criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p > 0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p > 0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars.

  2. A One-Year Evaluation of a Free Fissure Sealant Program.

    PubMed

    M, Bakhtiar; N, Azadi; A, Golkari

    2016-12-01

    Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran's oral health reform plan is not clear. To evaluate the longevity of different fissure sealant applied in Iran's oral health reform plan in Fars Province (south of Iran) after one year. Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant ( p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child's gender, age, and being caries-free. Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application.

  3. Anal Fissure

    PubMed Central

    Beaty, Jennifer Sam; Shashidharan, M.

    2016-01-01

    Anal fissure (fissure-in-ano) is a very common anorectal condition. The exact etiology of this condition is debated; however, there is a clear association with elevated internal anal sphincter pressures. Though hard bowel movements are implicated in fissure etiology, they are not universally present in patients with anal fissures. Half of all patients with fissures heal with nonoperative management such as high fiber diet, sitz baths, and pharmacological agents. When nonoperative management fails, surgical treatment with lateral internal sphincterotomy has a high success rate. In this chapter, we will review the symptoms, pathophysiology, and management of anal fissures. PMID:26929749

  4. A One-Year Evaluation of a Free Fissure Sealant Program

    PubMed Central

    M, Bakhtiar; N, Azadi; A, Golkari

    2016-01-01

    Statement of Problem: Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran’s oral health reform plan is not clear. Objectives: To evaluate the longevity of different fissure sealant applied in Iran’s oral health reform plan in Fars Province (south of Iran) after one year. Materials and Methods: Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Results: Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant (p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child’s gender, age, and being caries-free. Conclusions: Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application. PMID

  5. Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents.

    PubMed

    Ahovuo-Saloranta, A; Hiiri, A; Nordblad, A; Worthington, H; Mäkelä, M

    2004-01-01

    Fissure sealants used on occlusal tooth surfaces were introduced in the 1960s for protecting pits and fissures from dental caries. Although sealants have demonstrated to be effective in preventing caries, their efficacy may be related to the background caries prevalence in the population. The primary objective of this review was to evaluate the caries prevention of resin based pit and fissure sealants and glass ionomer cements or sealants in children and adolescents. We searched the Cochrane Oral Health Group's Trials Register (last update December 2002), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 4, 2002), MEDLINE via OVID (1966 to December 2002), EMBASE (1974 to February 2002), SCISEARCH, SIGLE, CAplus, INSPEC, JICST-EPLUS, NTIS, PASCAL (February 2002) and DARE, NHS EED, HTA (March 2002). Reference lists from included articles and review articles were searched for additional relevant articles. All relevant studies in most languages were considered and translated. Randomised or quasi-randomised controlled trials of at least 12 months in duration in which sealants were used for preventing caries in children and adolescents under 20 years of age were included. The primary outcome was the increment in the numbers of carious occlusal surfaces of premolars and molars. In the first phase, two reviewers independently examined whether a given study was likely to be relevant on the basis of the title, key words and abstract. In the second phase, four of the reviewers independently classified studies to be included in final analyses. Study authors were contacted for additional information. In the split-mouth studies relative risk ratios were calculated for the paired differences of tooth surfaces being carious or not. In studies comparing resin based sealant with no treatment, fixed effect meta-analyses were used to combine the estimates of relative risk ratios. In one parallel group study, the mean DFS data as continuous data

  6. Performance of some diagnostic systems in the prediction of occlusal caries in permanent molars in 6- and 11-year-old children.

    PubMed

    Fennis-Ie, Y L; Verdonschot, E H; van't Hof, M A

    1998-01-01

    Attempts have been made to develop diagnostic methods which enable an early diagnosis of occlusal lesions which are not detectable by visual inspection. The aim of this study was to compare the performance of visual inspection focused on finding signs of fissure decalcification and discoloration, visual inspection upon fibre-optic transillumination (FOTI), and electrical conductance measurements (ECMs) in predicting the onset of occlusal caries in 6- and 11-year-old children. Fifty children aged 5-7 and 11-15 years, having first or second permanent molar teeth that were not exposed to the oral environment for more than half a year, participated in the study. Following baseline data recording, the diagnostic measurements were repeated six times at 6-month intervals over a period of 2.5 years. Data were collected at predefined sites in the fissures. During the study, 220 of the 652 sites, i.e. 75 of 197 molars in 31 of the 50 children were judged to require a sealant or a sealant restoration. Two examiners jointly decided on the decay status at the sites. Survival plots showed that ECMs were superior to FOTI and fissure discoloration in predicting the onset of occlusal caries, although the differences were small. ECM is a better predictor of occlusal caries than fissure discoloration and FOTI, although the differences among the performance of the three methods in this study were very small. A cost-effective analysis is envisaged to obtain insight into the practical value of ECMs in the prediction of occlusal caries and, thus, into the effectiveness of sealant application.

  7. A comparative study of fissure sealants Helioseal Clear Chroma and Delton FS(+): 3 year results.

    PubMed

    Kargul, B; Tanboga, I; Gulman, N

    2009-12-01

    To evaluate the retention rates of a resin based colour changing fissure sealant (Helioseal Clear Chroma; Ivoclar Vivadent AG Schaan, Liechtenstein) compared with a coloured resin based fluoride fissure sealant (Delton FS(+); Dentsply De Trey GmbH,Konstanz,Germany). The fissure sealants (FS) were placed on all 4 caries-free first permanent molars of 31 children aged 6-9 years, using a half mouth experimental design by a paediatric dentist according to the manufacturers' instructions. A total of 121 FS were placed at baseline. Teeth were evaluated at 3 month intervals for 36 months where a preventive program including topical fluoride application was applied. Retention rates for 36 months showed a differences between Delton FS(+) and Helioseal Clear Chroma that were statistically significant (p<0.05). Delton FS(+) had total retention rate of 30.4% for 36 months compared with Helioseal Clear Chroma at 10.8% for the same evaluation period. Although Delton FS(+) showed significantly better results than Helioseal Clear Chroma for the evaluation periods, there were no statistically significant differences between Delton FS(+) (90.7%) and Helioseal Clear Chroma (80.4%) with respect to caries incidence at 36 months(p>0.05). Delton FS(+) showed a better complete retention rate for occlusal FS at one year. Both FS were aesthetically acceptable and easy to see during application and follow-up periods and gave significant protection from occlusal decay.

  8. Microleakage and penetration depth of different fissure sealant materials after cyclic thermo-mechanic and brushing simulation.

    PubMed

    Hatirli, Hüseyin; Yasa, Bilal; Yasa, Elif

    2018-01-30

    The aim of the study was to evaluate microleakage and the penetration-depths of different fissure-sealant materials applied with/without enameloplasty after cyclic aging. One-hundred-sixty mandibular molars were divided into non-invasive and enameloplasty preparation groups and eight material subgroups, including: flowable composites (microhyrid, nanohybrid, and nanofilled), three resin-based (unfilled, filled, and highly-filled), a giomer-based, and a glass-ionomer-based fissure sealant. Specimens were subjected to two-year cyclic chewing and brushing simulation. After 5% basic-fuchsin dye penetration, specimens were sectioned and scored under stereomicroscope. Kruskal-Wallis statistical data showed that preparation type significantly affected the penetration of all tested materials (p<0.05), but not significantly affected microleakage (p>0.05). Flowable composites showed the best and the glass-ionomer-based sealant showed the worst penetration and microleakage. Slight preparation of fissures is not important in microleakage. However, enameloplasty significantly enhanced the depth of penetration of the sealants. Flowable composites offer promising results at the fissure sealing.

  9. Evidence-based clinical practice guideline for the use of pit-and-fissure sealants: A report of the American Dental Association and the American Academy of Pediatric Dentistry.

    PubMed

    Wright, John T; Crall, James J; Fontana, Margherita; Gillette, E Jane; Nový, Brian B; Dhar, Vineet; Donly, Kevin; Hewlett, Edmond R; Quinonez, Rocio B; Chaffin, Jeffrey; Crespin, Matt; Iafolla, Timothy; Siegal, Mark D; Tampi, Malavika P; Graham, Laurel; Estrich, Cameron; Carrasco-Labra, Alonso

    2016-08-01

    This article presents evidence-based clinical recommendations for the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars in children and adolescents. A guideline panel convened by the American Dental Association (ADA) Council on Scientific Affairs and the American Academy of Pediatric Dentistry conducted a systematic review and formulated recommendations to address clinical questions in relation to the efficacy, retention, and potential side effects of sealants to prevent dental caries; their efficacy compared with fluoride varnishes; and a head-to-head comparison of the different types of sealant material used to prevent caries on pits and fissures of occlusal surfaces. This is an update of the ADA 2008 recommendations on the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars. The authors conducted a systematic search in MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and other sources to identify randomized controlled trials reporting on the effect of sealants (available on the US market) when applied to the occlusal surfaces of primary and permanent molars. The authors used the Grading of Recommendations Assessment, Development, and Evaluation approach to assess the quality of the evidence and to move from the evidence to the decisions. The guideline panel formulated 3 main recommendations. They concluded that sealants are effective in preventing and arresting pit-and-fissure occlusal carious lesions of primary and permanent molars in children and adolescents compared with the nonuse of sealants or use of fluoride varnishes. They also concluded that sealants could minimize the progression of noncavitated occlusal carious lesions (also referred to as initial lesions) that receive a sealant. Finally, based on the available limited evidence, the panel was unable to provide specific recommendations on the relative merits of 1 type of sealant material over the others. These

  10. Thoracoscopic anterior ‘fissure first’ technique for left lung cancer with an incomplete fissure

    PubMed Central

    Samejima, Joji; Matsuura, Yosuke; Nakao, Masayuki; Uehara, Hirofumi; Nakagawa, Ken; Masuda, Munetaka; Okumura, Sakae

    2016-01-01

    Background Dealing with incomplete lung fissures during thoracoscopic surgery is difficult. Our objective was to evaluate the efficacy and safety of a thoracoscopic anterior ‘fissure first’ technique for dealing with incomplete left lung fissures. Methods One hundred and seventy patients underwent left upper lobectomy or left lower lobectomy between April 2008 and July 2014. Of these, 34 patients underwent surgery using a thoracoscopic anterior ‘fissure first’ technique for incomplete fissures (group A) and 136 underwent surgery using a conventional thoracoscopic method for unfused fissures (group B). A four-port complete thoracoscopic approach was used in all patients. After completion of the fissure, hilar lymphadenectomy was performed in the conventional manner. Results There were no significant differences between the two groups in operating time, blood loss, or duration of chest tube drainage. Patients in group A required more staple cartridges than those in group B (mean number of cartridges, 2.4 vs. 1.1; P<0.01). The two groups did not significantly differ with regard to the prevalence of air leaks (12% vs. 4%; P=0.11), either prolonged or delayed. Conclusions We found that a thoracoscopic anterior ‘fissure first’ technique for left lung cancer with an incomplete fissure enabled hilar lymphadenectomy to be performed in the conventional manner without any increase in the prevalence of air leaks, operating time, or duration of chest tube drainage. This technique should be considered for use in left upper lobectomy or left lower lobectomy in patients with an incomplete fissure. PMID:28066589

  11. SURFACE FISSURE FORMATION ABOVE UNDERGROUND COALSEAM FIRES: DIMENSIONLESS RELATIONSHIPS BETWEEN SURFACE FISSURES AND SUBSURFACE SUBSIDENCE

    NASA Astrophysics Data System (ADS)

    Ide, T. S.; Pollard, D. D.; Orr, F. M.

    2009-12-01

    Coalbed fires are uncontrolled subsurface fires that occur around the world. These fires are believed to be significant contributors to annual CO2 emissions. Although many of these fires have been burning for decades, researchers have only recently begun to investigate physical mechanisms that control fire behavior. One aspect that is poorly characterized is the relationship between subsurface combustion and surface fissures. At the surface above many fires, long, wide fissures are observed. At a coalbed fire near Durango, Colorado, these fissures form systematic orthogonal patterns that align with regional joints in the Upper Cretaceous Fruitland Formation. Understanding the mechanisms that form and widen these fissures is important, as the fissures are believed to play vital roles in sustaining the combustion in the subsurface by acting as chimneys for the escaping gases and conduits for incoming oxygen. In some of the coalbed fire simulation models available today, these fissures are treated as fixed boundary conditions, but we argue, using field observations and simulation results, that there exists a relationship between the location and magnitude of subsidence caused by the fire and the opening of fissures. Four distinct types of fissures are observed over the coalbed fire near Durango, CO. These fissures are termed ‘molehill’, ‘plateau’, ‘gaping’, and ‘narrow’ based on their surface appearances. Molehill fissures are marked by surface depressions on either side, causing the strata around the opening to form an apex towards the center of the fissure. Plateau fissures show a steep vertical offset on only one side with minimal horizontal displacement. Gaping fissures and narrow fissures are predominantly opening with little evidence for vertical displacements. Gaping fissures are defined as fissures with wide apertures (0.3 ~ 1.5m), while narrow fissures have apertures on the order of centimeters. A boundary element method code was used to show

  12. Shallow Subsurface Structures of Volcanic Fissures

    NASA Astrophysics Data System (ADS)

    Parcheta, C. E.; Nash, J.; Mitchell, K. L.; Parness, A.

    2015-12-01

    Volcanic fissure vents are a difficult geologic feature to quantify. They are often too thin to document in detail with seismology or remote geophysical methods. Additionally, lava flows, lava drain back, or collapsed rampart blocks typically conceal a fissure's surface expression. For exposed fissures, quantifying the surface (let along sub0surface) geometric expression can become an overwhelming and time-consuming task given the non-uniform distribution of wall irregularities, drain back textures, and the larger scale sinuosity of the whole fissure system. We developed (and previously presented) VolcanoBot to acquire robust characteristic data of fissure geometries by going inside accessible fissures after an eruption ends and the fissure cools off to <50 C. Data from VolcanoBot documents the fissure conduit geometry with a near-IR structured light sensor, and reproduces the 3d structures to cm-scale accuracy. Here we present a comparison of shallow subsurface structures (<30 m depth) within the Mauna Ulu fissure system and their counterpart features at the vent-to-ground-surface interface. While we have not mapped enough length of the fissure to document sinuosity at depth, we see a self-similar pattern of irregularities on the fissure walls throughout the entire shallow subsurface, implying a fracture mechanical origin similar to faults. These irregularities are, on average, 1 m across and protrude 30 cm into the drained fissure. This is significantly larger than the 10% wall roughness addressed in the engineering literature on fluid dynamics, and implies that magma fluid dynamics during fissure eruptions are probably not as passive nor as simple as previously thought. In some locations, it is possible to match piercing points across the fissure walls, where the dike broke the wall rock in order to propagate upwards, yet in other locations there are erosional cavities, again, implying complex fluid dynamics in the shallow sub-surface during fissure eruptions.

  13. European Fissure Sealant Guidelines: assessment using AGREE II.

    PubMed

    San Martin-Galindo, L; Rodríguez-Lozano, F J; Abalos-Labruzzi, C; Niederman, R

    2017-02-01

    Pit and fissure sealants are effective in reducing the incidence of occlusal caries, and multiple clinical practice guidelines (CPGs) have been developed for recommending their proper use. The usefulness of CPGs depends on their quality and on the rigour of the guideline development process. A study was made to assess the quality of current European CPGs based on the Appraisal of Guidelines for Research and Evaluation (AGREE II) instrument, which uses 23 key items rated on a 7-point scale to assess practice guideline development and the quality of reporting. A search was conducted for fissure sealant guidelines for preventing caries in children and adults at high and low risk published in the last 10 years. Calibration was carried out before scoring to assess agreement between the appraisers using the AGREE II instrument. The searches identified 19 relevant guidelines, and following application of the inclusion/exclusion criteria, three guidelines were retained for evaluation. The proportion of observed agreement was calculated, expressed by the agreement separately for positive and negative ratings (PA = 0.89, NA = 0-91). The results of the guideline assessments revealed the highest score for the Irish guideline, a moderate score for the French guideline and the lowest score for the European guideline. Based on the AGREE II instrument, the results obtained show significant variation in the quality assessment of the three European Fissure Sealant Guidelines. Future studies should be carried out both to develop quality dental CPGs and to investigate effective ways of adopting them. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Pulmonary Lobe Segmentation with Probabilistic Segmentation of the Fissures and a Groupwise Fissure Prior

    PubMed Central

    Bragman, Felix J.S.; McClelland, Jamie R.; Jacob, Joseph; Hurst, John R.; Hawkes, David J.

    2017-01-01

    A fully automated, unsupervised lobe segmentation algorithm is presented based on a probabilistic segmentation of the fissures and the simultaneous construction of a population model of the fissures. A two-class probabilistic segmentation segments the lung into candidate fissure voxels and the surrounding parenchyma. This was combined with anatomical information and a groupwise fissure prior to drive non-parametric surface fitting to obtain the final segmentation. The performance of our fissure segmentation was validated on 30 patients from the COPDGene cohort, achieving a high median F1-score of 0.90 and showed general insensitivity to filter parameters. We evaluated our lobe segmentation algorithm on the LOLA11 dataset, which contains 55 cases at varying levels of pathology. We achieved the highest score of 0.884 of the automated algorithms. Our method was further tested quantitatively and qualitatively on 80 patients from the COPDGene study at varying levels of functional impairment. Accurate segmentation of the lobes is shown at various degrees of fissure incompleteness for 96% of all cases. We also show the utility of including a groupwise prior in segmenting the lobes in regions of grossly incomplete fissures. PMID:28436850

  15. Effects of subpressure on the sealing ability of dental sealant in vitro.

    PubMed

    Tian, Y M; Zhuge, R S; Zhang, Z T; Zheng, D X; Ding, N; Li, Y M

    2018-06-06

    Pits and fissures sealing with flowable materials is a popular method for preventing caries in preventive dentistry while there is still microleakage existed. This in vitro study aimed to explore the effects of subpressure technique on the sealing ability of pit and fissure sealant. One hundred and forty-one extracted human premolars were collected in this study and treated with different pressure (atmosphere pressure as group C, -0.04 MPa as group S 4 and -0.08 MPa as group S 8 ). Thermocycling (×5000) was also performed. Penetration percentage, microleakage, cross-sectional microhardness (Knoop, KMH) and mineral loss were evaluated. Kappa tests, Friedman nonparametric and two-way ANOVA were used for data analysis. Penetration percentages of group S 4 and S 8 were significant higher compared to that of group C. Microleakage of groups was similar before thermocycling, while subpressure groups showed lower scale of microleakage after thermocycling. Data of KMH and mineral loss showed significant differences between subpressure and thermocycling groups. Subpressure technique could increase the penetration of pit and fissure sealant, decrease microleakage and increase resistance of demineralization after thermocycling. This novel technique may have great potential for preventing from secondary caries. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Mechanical Performance of Two Left Atrial Appendage Occlusion Systems: In Vitro Comparison of Tug Force, Radial Force, Sealing and Deformation.

    PubMed

    Menne, Matthias F; Schrickel, Jan W; Nickenig, Georg; Al-Kassou, Baravan; Nelles, Dominik; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Sedaghat, Alexander

    2018-05-24

    The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech ® , of three different sizes underwent testing in novel dedicated in vitro setups. Radial force was assessed in a commercial radial force tester. At baseline, tug force of the WATCHMAN™ was significantly higher when compared to Occlutech ® for all devices. Repeated resheathing resulted in a reduction of device-diameter in the WATCHMAN™ devices of max. 7.9%, whereas diameters of Occlutech ® occluders remained unchanged. Tug force was not significantly impacted by resheathing in both devices. At baseline, sealing capacity in a bench-test using silicone LAA-models did not differ between the devices. Resheathing lead to an in vitro loss of sealing capacity of the WATCHMAN™ devices, increasing with resheathing and resulting in a max. peridevice leak of 91.1 ± 7.9%. Radial force was higher for the Occlutech ® devices and decreased for WATCHMAN™ occluders after resheathing. The WATCHMAN™ occluder series showed progressive deformation, increased peridevice leakage and decreased radial force after resheathing, presumably as a result of diameter reduction. Tug force of the WATCHMAN™ was not impaired by resheathing and was significantly higher than that of the Occlutech ® device.

  17. Mechanism of Earth Fissures in Beijing,China

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Gong, H.; Gu, Z.; Wang, R.; Jia, S.; Li, X.

    2013-12-01

    Earth fissure is one of the natural hazards that can occur due to different mechanisms. The Beijing city, located in the north of North China Plain, China, has undergone extensive fissuring for the last twenty years. These fissures have caused serious damages to homes, farmlands and infrastructures. The previous investigation shows the distribution and direction of the major earth fissures mostly paralleled to the active fault, such as Huangzhuang-Gaoliying Fault. Hence, tectonic movements were thought to be the major cause of the fissuring in this region. But the subsidence caused by overdraft and other geological, hydrological and mechanical factors may also play important roles in forming earth fissure. The purpose of the work was to further explores the reason for the cause of the earth fissures and their mechanism of formations using field investigations, geophysical surveys, geotechnical tests and numerical analysis. The results indicated that over-extraction groundwater and differential subsidence are the major causes of the fissuring. The active faulting and fault zone provided or created an ideal condition for stress to accumulate. The earth fissures occur at times when the accumulated stress exceed the strength of soil or coupled with other process by which the strength of soil material is reduced. Survey and simulated results reveal the complex pattern of earth fissure including tensile deformation, vertical offset and rotation. The potential locations for future damage were also evaluated. Keywords: Earth Fissure; Mechanism; Beijing; Subsidence; tectonic movement; Geophysical survey

  18. The Bacterial Flora of Incipient Occlusal Lesions in Naval Recruits.

    DTIC Science & Technology

    1980-07-01

    fluoridation of water and dental caries experiences. Int. Dent. J. 17:582-665, 1967. 15. Koch, G. Effect of sodium fluoride in dentifrice and mouthwash on...WIRTHLIN, JR. Captain, DC, USN Commanding Officer Dental caries is a bacterial disease in which the prime etiological agent(s) responsible for its...that dental caries occurs more frequently in occlusal fissures rather than on smooth surfaces, which have up to now received the major share of study

  19. Influence of etching time and bonding strategies on the microshear bond strength of self- and light-cured pit-and-fissure sealants.

    PubMed

    Souza-Junior, Eduardo José; Borges, Boniek Castillo Dutra; Montes, Marcos Antônio Japiassú Resende; Alonso, Roberta Caroline Bruschi; Ambrosano, Glaucia Maria Bovi; Sinhoreti, Mário Alexandre Coelho

    2012-01-01

    This study evaluated the impact of extended etching and bonding strategies on the microshear bond strength of three sealant materials. Two pit-and-fissure sealants [FluroShield, Dentsply (light-cured) and AlphaSeal, DFL (self-cured)] and one light-cured flowable composite resin (Permaflo, Ultradent) were evaluated according to different enamel etching times (15 s or 30 s) and bonding procedures (no adhesive application, application of primer/hydrophobic resin or hydrophobic resin only). Intact enamel blocks were obtained from bovine teeth and sealed via the tested protocols. After 24 h, the microshear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were classified by stereomicroscopy. Data were submitted to a three-way ANOVA and to Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) among the materials. Permaflo showed higher bond strength when etched for 30 s alone. Enamel overetching decreased the bond strength of the light-cured sealant. Primer/bond previous treatment improved bond performance for AlphaSeal. In conclusion, from the tested conditions, all sealant materials presented similar bond strength values in relation to bonding protocol and etching time. The flowable composite can be used as a pit-and-fissure sealant. The use of a three-step adhesive system was essential for the self-cured sealant application.

  20. The use of a 'bleach-etch-seal' deproteinization technique on MIH affected enamel.

    PubMed

    Gandhi, Shan; Crawford, Peter; Shellis, Peter

    2012-11-01

    To ascertain whether deproteinization pretreatment of molar-incisor hypomineralization (MIH) enamel affects resin sealant infiltration. Thirty one extracted MIH teeth were divided into three sections and randomly allocated into the Control (etch and FS), Treatment 1 (5% NaOCl, etched and fissure sealed), and Treatment 2 (5% NaOCl and fissure sealed with no etch) groups. Two hundred seventy nine sealant tag/enamel grade observations were recorded by scanning electron microscopy. Control and Treatment 1 were similar in their outcomes, and Treatment 2 was markedly different. There was no statistical evidence to suggest that there was any difference between Treatment 1 and the Control Treatment (95% CI, 0.52, 1.51; P = 0.6). There was a marked difference between Treatment 2 and the Control Treatment (95% CI, 0.07, 0.25; P < 0.001). All treatments also demonstrated a high-predicted probability of obtaining 'poor' sealant tags (Control = 47%, Treatment 1 = 49%, and Treatment 2 = 40%). The findings suggest that there was no significant difference in the tag quality between the conventional technique (Control) and the 'bleach-etch-seal' technique (Treatment 1). There was no benefit in pre-treating with NaOCl alone (without etch) before sealing. This research also showed that there was a high-predicted probability of obtaining 'poor' sealant tags in MIH enamel, regardless of which of the three treatments was used. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  1. Evaluation of non-invasive treatment applied to occlusal surfaces.

    PubMed

    Flório, F M; Pereira, A C; Meneghim, M de C; Ramacciato, J C

    2001-01-01

    The purpose of this study was to evaluate the efficacy of non-invasive methods of treatment for active incipent occlusal caries. Anamnesis, professional prophylaxis, and visual inspection were used to classify 250 Brazilian pre-school-children. First permanent decayed molars (n=98) from thirty-one subjects (6 years+ 6 months) were selected and divided into three groups. Group 1: fissure sealants with resin-modified glass ionomer - Vitremer (n=29); Group 2: fluoride varnish -Duraphat (n=36) and control group: tooth brushing and 0.2 percent NaF weekly mouthwashes (n=33). Four clinical evaluations were carried out over three, six, nine, and twelve months. Caries activity and progression were observed through clinical and radiographic evaluation. The results were analyzed by Fisher=s Exact test. After twelve months, the results showed 100 percent of arrestment of caries activity for Group 1, 83.3 percent for group 2, and 72.7 percent for control group. At the same time, the results showed 0 percent of caries progression for group 1, 5.5 percent for Group 2, and 6.1 percent for control group. Group 1 showed a better inactivation property than the other groups (p<0.05). There were no statistically significant differences in caries progression among these groups (p>0.05). It was concluded that this non-invasive methods were able to arrest the progression of occlusal caries, but fissure sealant showed better results in controlling caries activity.

  2. [Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing].

    PubMed

    Su, Hong-Ru; Xu, Pei-Cheng; Qian, Wen-Hao

    2016-06-01

    To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P<0.05). No significant difference was found between C1 and C2 groups (P>0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P<0.05). The caries rate in A1and A2, B1 and B2, C1 and C2 group had no significant difference during different follow-up time (P>0.05). The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.

  3. SWIR reflectance imaging of demineralization on the occlusal surfaces of teeth beyond 1700 nm

    NASA Astrophysics Data System (ADS)

    Ng, Chung; Simon, Jacob C.; Fried, Daniel; Darling, Cynthia L.

    2018-02-01

    Most new lesions are found in the pits and fissures of the occlusal surface. Radiographs have extremely low sensitivity for early occlusal decay and by the time the lesion is severe enough on a radiograph it typically has penetrated well into the dentin and surgical intervention is required. The occlusal surfaces are heavily stained and visual and tactile methods for their detection also have poor sensitivity and specificity. Previous studies at wavelengths beyond 1300-nm have demonstrated that stains are not visible and demineralization on the occlusal surfaces can be viewed without interference from stains. New extended range InGaAs near- IR cameras allow access to wavelengths beyond 1700-nm. The objective of this study was to determine how the contrast of occlusal lesions varies with wavelength from the visible to 2350-nm. The lesion contrast was measured in 55 extracted teeth with suspected occlusal lesions using reflectance measurements from 400- 2350-nm using Si and InGaAs imaging arrays. The highest lesion contrast in reflectance was measured at wavelengths greater than 1700-nm. Stains interfered significantly at wavelengths shorter than 1150-nm. This study indicates that the optimum wavelengths for reflectance imaging decay in the occlusal surfaces are greater than 1700-nm.

  4. Pit and fissure sealants in dental public health – application criteria and general policy in Finland

    PubMed Central

    Kervanto-Seppälä, Sari; Pietilä, Ilpo; Meurman, Jukka H; Kerosuo, Eero

    2009-01-01

    Background Pit and fissure sealants (sealants) are widely used as a non-operative preventive method in public dental health in Finland. Most children under 19 years of age attend the community-organized dental health services free of charge. The aims of this study were to find out to what extent sealants were applied, what the attitudes of dental professionals towards sealant application were, and whether any existing sealant policies could be detected among the health centres or among the respondents in general. The study evaluated changes that had taken place in the policies used during a ten year period (1991–2001). Methods A questionnaire was mailed to each chief dental officer (CDO) of the 265 public dental health centres in Finland, and to a group of general dentists (GDP) applying sealants in these health centres, giving a total of 434 questionnaires with 22 questions. The response rate was 80% (N = 342). Results A majority of the respondents reported to application of sealants on a systematic basis for children with increased caries risk. The criteria for applying sealants and the actual strategies seemed to vary locally between the dentists within the health centres and between the health centres nationwide. The majority of respondents believed sealants had short- and long-term effects. The overall use of sealants decreased towards the end of the ten year period. The health centres (N = 28) choosing criteria to seal over detected or suspected enamel caries lesion had a DMFT value of 1.0 (SD ± 0.49) at age 12 (year 2000) compared to a value of 1.2 (SD ± 0.47) for those health centres (N = 177) applying sealants by alternative criteria (t-test, p < 0.05). Conclusion There seems to be a need for defined guidelines for sealant application criteria and policy both locally and nationwide. Occlusal caries management may be improved by shifting the sealant policy from the traditional approach of prevention to interception, i.e. applying the sealants over

  5. A Volcanic Fissure

    NASA Image and Video Library

    2017-04-26

    Although Mars is known for having the largest volcano in our solar system, Olympus Mons, we also find small-scale volcanic features on its surface, as shown in this image from HiRISE onboard NASA's Mars Reconnaissance Orbiter (MRO). This fissure, less than 500 meters across at its widest point, lies in the Tharsis region and is believed to be a vent from which lava flowed in ancient eruptions. The total volume of lava released from this fissure is much less than what would erupt from nearby volcanoes, but the mark left on the landscape is dramatic nonetheless. https://photojournal.jpl.nasa.gov/catalog/PIA21601

  6. Effect of three surface sealants on marginal sealing of Class V composite resin restorations.

    PubMed

    Ramos, R P; Chimello, D T; Chinelatti, M A; Dibb, R G; Mondelli, J

    2000-01-01

    This study evaluated in vitro the effectiveness of three different surface sealants (Fortify, Protect-it! and Optiguard) on the marginal sealing of Class V light-activated composite resin restorations (Prodigy). For this purpose, 20 sound noncarious human premolars extracted within a six-month period were selected. Class V cavities with the occlusal margin in enamel and cervical margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with 10 cavities in each group, were restored with composite resin after applying an adhesive system (Optibond FL). After the finishing and polishing procedures, the restorations were covered with a specific surface sealant, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled and immersed in a 50% silver nitrate solution (tracer agent) for eight hours, sectioned longitudinally and analyzed for leakage using an optical microscope in a blind study with three examiners. The marginal microleakage was evaluated at the occlusal and cervical interfaces and compared among the four groups using the Kruskall-Wallis and the Wilcoxon Tests. There was better sealing at the occlusal margin, and in this region, there were no statistically significant differences among the materials (p > 0.05). In the cervical region, Fortify and Protect-it! showed improved results over the Control Group, and Optiguard showed similar results to the Control Group (without sealing).

  7. Anomalous sylvian fissure morphology in Williams syndrome.

    PubMed

    Eckert, Mark A; Galaburda, Albert M; Karchemskiy, Asya; Liang, Alyssa; Thompson, Paul; Dutton, Rebecca A; Lee, Agatha D; Bellugi, Ursula; Korenberg, Julie R; Mills, Debra; Rose, Fredric E; Reiss, Allan L

    2006-10-15

    The unusual sensitivity and attraction to auditory stimuli in people with Williams syndrome (WS) has been hypothesized to be the consequence of atypical development of brain regions surrounding the Sylvian fissure. Planum temporale surface area, which is determined in part by Sylvian fissure patterning, was examined in 42 WS and 40 control participants to determine if anomalous Sylvian fissure morphology is present in WS. WS participants had significantly reduced leftward asymmetry of the planum temporale compared to control participants, due to a significant expansion in the size of the right planum temporale. The increased right planum temporale size was largely due to WS participants (24%) who had a right hemisphere Sylvian fissure that coursed horizontally and failed to ascend into the parietal lobe. This sulcal pattern is unusual in the right hemisphere and is more commonly found in the left hemisphere of typically developing individuals. There were no control participants with this type of right hemisphere Sylvian fissure pattern. The right hemisphere Sylvian fissure sulcal patterns were also related to a measure of cortical complexity and the amount of right hemisphere occipital lobe volume, suggesting that intrinsic genetic influences leading to anomalous visual system development in WS have widespread influences on cortical morphology that are similar in manner to extrinsic embryonic visual system lesions.

  8. Recent ground fissures in the Hetao basin, Inner Mongolia, China

    NASA Astrophysics Data System (ADS)

    He, Zhongtai; Ma, Baoqi; Long, Jianyu; Zhang, Hao; Liang, Kuan; Jiang, Dawei

    2017-10-01

    Ground fissures are a geological hazard with complex formation mechanisms. Increasing amounts of human activity have created more ground fissures, which can destroy buildings and threaten human security. Some ground fissures indicate potentially devastating earthquakes, so we must pay attention to these hazards. This paper documents recently discovered ground fissures in the Hetao basin. These ground fissures are located along the frontal margins of the terraces of the Sertengshan piedmont fault. These fissures are 600-1600 m long, 5-50 cm wide, and at most 1 m deep. These ground fissures emerged after 2010 and ruptured newly constructed roads and field ridges. The deep geodynamic mechanisms within this extensional environment, which is dominated by NE-SW principal compressive shear, involve N-S tensile stress, which has produced continuous subsidence in the Hetao basin and continuous activity along the Sertengshan piedmont fault since the late Quaternary. Trenches across the ground fissures reveal that the fissures are the latest manifestation of the activity of preexisting faults and are the result of creep-slip movement along the faults. The groundwater level in the Hetao basin has been dropping since the 1960s because of overexploitation, resulting in subsidence. When the tensile stress exceeds the ultimate tensile strength of the strata, the strata rupture along preexisting faults, producing ground fissures. Thus, the Sertengshan piedmont fault planes are the structural foundation of the ground fissures, and groundwater extraction induces the development of ground fissures.

  9. Quantitative light-induced fluorescence (QLF): a tool for early occlusal dental caries detection and supporting decision making in vivo.

    PubMed

    Alammari, M R; Smith, P W; de Josselin de Jong, E; Higham, S M

    2013-02-01

    This study reports the development and assessment of a novel method using quantitative light-induced fluorescence (QLF), to determine whether QLF parameters ΔF and ΔQ were appropriate for aiding diagnosis and clinical decision making of early occlusal mineral loss by comparing QLF analysis with actual restorative management. Following ethical approval, 46 subjects attending a dental teaching hospital were enrolled. White light digital (WL) and QLF images/analyses of 46 unrestored posterior teeth with suspected occlusal caries were made after a clinical decision had already been taken to explore fissures operatively. WL and QLF imaging/analysis were repeated after initial cavity preparation. The type of restorative treatment was determined by the supervising clinician independent of any imaging performed. Actual restorative management carried out was recorded as fissure sealant/preventive resin restoration (F/P) or class I occlusal restoration (Rest.) thus reflecting the extent of intervention (=gold standard). All QLF images were analysed independently. The results showed statistically significant differences between the two treatment groups ΔF (p=0.002) (mean 22.60 - F/P and 28.80 - Rest.) and ΔQ (p=0.012) (mean 230.49 - F/P and 348.30 - Rest.). ΔF and ΔQ values may be useful in aiding clinical diagnosis and decision making in relation to the management of early mineral loss and restorative intervention of occlusal caries. QLF has the potential to be a valuable tool for caries diagnosis in clinical practice. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. A visualization system for CT based pulmonary fissure analysis

    NASA Astrophysics Data System (ADS)

    Pu, Jiantao; Zheng, Bin; Park, Sang Cheol

    2009-02-01

    In this study we describe a visualization system of pulmonary fissures depicted on CT images. The purpose is to provide clinicians with an intuitive perception of a patient's lung anatomy through an interactive examination of fissures, enhancing their understanding and accurate diagnosis of lung diseases. This system consists of four key components: (1) region-of-interest segmentation; (2) three-dimensional surface modeling; (3) fissure type classification; and (4) an interactive user interface, by which the extracted fissures are displayed flexibly in different space domains including image space, geometric space, and mixed space using simple toggling "on" and "off" operations. In this system, the different visualization modes allow users not only to examine the fissures themselves but also to analyze the relationship between fissures and their surrounding structures. In addition, the users can adjust thresholds interactively to visualize the fissure surface under different scanning and processing conditions. Such a visualization tool is expected to facilitate investigation of structures near the fissures and provide an efficient "visual aid" for other applications such as treatment planning and assessment of therapeutic efficacy as well as education of medical professionals.

  11. Influence of laser irradiation on pits and fissures: an in situ study.

    PubMed

    Correa-Afonso, Alessandra M; Pécora, Jesus D; Palma-Dibb, Regina G

    2013-02-01

    The aim of this in situ study was to analyze the influence of the Er:YAG, Nd:YAG, and CO(2) lasers on the enamel acid resistance of pits and fissures. The laser tissue interaction has been studied as a method of preventing occlusal caries. Thirteen volunteers wore palatal acrylic appliances containing human occlusal enamel blocks that were divided into four groups (G1, control; G2, Er:YAG; G3, Nd:YAG; G4, CO(2)). Each palatal acrylic appliance was used in the four studied groups and was used for 14 consecutive days. A sucrose solution was applied to the specimens six times per day. The specimens were then sectioned in half, and a microhardness test was applied. The other halves were analyzed using polarized light microscopy to measure the caries-like lesion areas, and a morphological analysis was conducted using a scanning electron microscope (SEM). For the statistical analysis of the data obtained from the microhardness test (Knoop hardness number. [KHN]) (α=5%), Fisher's exact test was performed, and the group means were as follows: G1, 247±71; G2, 258±70; G3, 272±73; and G4, 298±56. The results demonstrated that the control group was significantly different from G3 and G4, which presented higher microhardness values. The Wilcoxon signed-rank test was used to analyze the data obtained from the caries-lesion area measurements (mm(2)) (α=5%) (G1, 0.01±1.08; G2, 0.13±0.18; G3, 0.05±0.17; and G4, 0.09±0.22). The results no showed significant differences among the groups in this analysis. Based on the results from the present study, it may be concluded that the CO(2) and Nd:YAG lasers increased the enamel acid resistance in pits and fissures.

  12. Assessment of microleakage of class V restored by resin composite and resin-modified glass ionomer and pit and fissure resin-based sealants following Er:YAG laser conditioning and acid etching: in vitro study

    PubMed Central

    Luong, Emilie; Shayegan, Amir

    2018-01-01

    Aim The aim of this study was to make a comparison between microleakage of conventionally restored class V cavities using acid etchant and the ones conditioned by erbium-doped yttrium aluminum garnet (Er:YAG) laser, and also to assess and compare the effectiveness of enamel surface treatments of occlusal pits and fissures by acid etching and conditioned by Er:YAG laser-etch. Materials and methods Seventy-two extracted third molars were used in this study. The samples were divided into two major groups: class V cavities and pit and fissure sealants. Each subgroup was divided into conventional acid etching, Er:YAG laser conditioning and conventional acid etching, and combination with Er:YAG laser conditioning (n=12). The teeth were placed in 2% methylene blue dye solution, were sectioned, and were evaluated according to the dye penetration criteria. Two samples per subgroup were chosen for scanning electron microscopic (SEM) analysis. Results There was a significant difference between occlusal and cervical margin groups. Laser conventional composite cementum group showed more microleakage values compared to other groups. There was no significant difference between occlusal margin groups. However, there was a significant difference between cervical margin groups in terms of microleakage. In sealant groups, there was a significant difference between laser and conventional with/without laser treatment groups in terms of microleakage. Conclusion Based on the results reported in this study, it can be concluded that the application of the Er:YAG laser beneath the resin composite, the resin-modified glass ionomers (GIs), and the fissure sealant placement may be an alternative enamel and dentin etching method to acid etching. PMID:29881311

  13. Lung fissure detection in CT images using global minimal paths

    NASA Astrophysics Data System (ADS)

    Appia, Vikram; Patil, Uday; Das, Bipul

    2010-03-01

    Pulmonary fissures separate human lungs into five distinct regions called lobes. Detection of fissure is essential for localization of the lobar distribution of lung diseases, surgical planning and follow-up. Treatment planning also requires calculation of the lobe volume. This volume estimation mandates accurate segmentation of the fissures. Presence of other structures (like vessels) near the fissure, along with its high variational probability in terms of position, shape etc. makes the lobe segmentation a challenging task. Also, false incomplete fissures and occurrence of diseases add to the complications of fissure detection. In this paper, we propose a semi-automated fissure segmentation algorithm using a minimal path approach on CT images. An energy function is defined such that the path integral over the fissure is the global minimum. Based on a few user defined points on a single slice of the CT image, the proposed algorithm minimizes a 2D energy function on the sagital slice computed using (a) intensity (b) distance of the vasculature, (c) curvature in 2D, (d) continuity in 3D. The fissure is the infimum energy path between a representative point on the fissure and nearest lung boundary point in this energy domain. The algorithm has been tested on 10 CT volume datasets acquired from GE scanners at multiple clinical sites. The datasets span through different pathological conditions and varying imaging artifacts.

  14. A clinical trial to evaluate the retention of a silver cermet-ionomer cement used as a fissure sealant.

    PubMed

    Mills, R W; Ball, I A

    1993-01-01

    A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P < 0.01): 93% compared with 74% at six months, 81% compared with 65% at 12 months, and 83% compared with 58% at 24 months. When analyzed according to age range, the difference between the retention rates was statistically significant in the five- to 10-year-olds but not significant in the 11- to 16-year-olds. The conclusion reached in this study was that cermet cement was better retained than conventional resin sealants in younger children.

  15. Proximal lava drainage controls on basaltic fissure eruption dynamics

    NASA Astrophysics Data System (ADS)

    Jones, T. J.; Llewellin, E. W.; Houghton, B. F.; Brown, R. J.; Vye-Brown, C.

    2017-11-01

    Hawaiian basaltic eruptions commonly initiate as a fissure, producing fountains, spattering, and clastogenic lava flows. Most fissures rapidly localize to form a small number of eruptive vents, the location of which may influence the subsequent distribution of lava flows and associated hazards. We present results from a detailed field investigation of the proximal deposits of episode 1 of the 1969 fissure eruption of Mauna Ulu, Kīlauea, Hawai`i. Exceptional preservation of the deposits allows us to reconstruct vent-proximal lava drainage patterns and to assess the role that drainage played in constraining vent localization. Through detailed field mapping, including measurements of the height and internal depth of lava tree moulds, we reconstruct high-resolution topographic maps of the pre-eruption ground surface, the lava high-stand surface and the post-eruption ground surface. We calculate the difference in elevation between pairs of maps to estimate the lava inundation depth and lava drainage depth over the field area and along different segments of fissure. Aerial photographs collected during episode 1 of the eruption allow us to locate those parts of the fissure that are no longer exposed at the surface. By comparing with the inundation and drainage maps, we find that fissure segments that were inundated with lava to greater depths (typically 1-6 m) during the eruption later became foci of lava drainage back into the fissure (internal drain-back). We infer that, in these areas, lava ponding over the fissure suppressed discharge of magma, thereby favouring drain-back and stagnation. By contrast, segments with relatively shallow inundation (typically less than 1 m), such as where the fissure intersects pre-eruptive topographic highs, or where flow away from the vent (outflow) was efficient, are often associated with sub-circular vent geometries in the post-eruption ground surface. We infer that these parts of the fissure became localization points for ongoing

  16. Influence of various bonding techniques on the fracture strength of thin CAD/CAM-fabricated occlusal glass-ceramic veneers.

    PubMed

    Yazigi, Christine; Kern, Matthias; Chaar, Mohamed Sad

    2017-11-01

    To evaluate the efficiency of immediate dentin sealing and the effects of different bonding protocols on the fracture strength of CAD/CAM occlusal veneers bonded to exposed dentin. Ninety-six extracted maxillary premolars were initially divided into three main groups with 32 specimens each: without immediate dentin sealing, immediate dentin sealing/total etching and immediate dentin sealing/selective etching. Teeth were identically prepared in the dentin to receive occlusal veneers of 0.8mm thickness, milled from lithium disilicate ceramic blocks (IPS e.max CAD). Each main group was later subdivided, according to the pre-cementation surface etching protocol (total/selective), into two subgroups with 16 specimens each. All restorations were adhesively bonded using a resin cement (Variolink Esthetic). Half of the specimens of each subgroup were subjected to thermo-dynamic loading in a chewing simulator with 1,200,000 cycles at 10kg load. The other half and the surviving specimens were subjected to quasi-static loading until failure. Statistical analysis was performed using three-way ANOVA and Tukey's post-hoc tests. All specimens except one survived the artificial aging. A significantly higher fracture strength of restorations (p ≤ 0.001) was obtained when immediate dentin sealing was followed regardless of the etching method with values ranging from a minimum of 1122 ± 336N to a maximum of 1853 ± 333N. Neither the pre-cementation treatment nor the artificial aging had a statistical significant effect on the fracture strength. Immediate dentin sealing protocol is recommended whenever dentin is exposed during the preparation for thin glass-ceramic occlusal veneers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Robust pulmonary lobe segmentation against incomplete fissures

    NASA Astrophysics Data System (ADS)

    Gu, Suicheng; Zheng, Qingfeng; Siegfried, Jill; Pu, Jiantao

    2012-03-01

    As important anatomical landmarks of the human lung, accurate lobe segmentation may be useful for characterizing specific lung diseases (e.g., inflammatory, granulomatous, and neoplastic diseases). A number of investigations showed that pulmonary fissures were often incomplete in image depiction, thereby leading to the computerized identification of individual lobes a challenging task. Our purpose is to develop a fully automated algorithm for accurate identification of individual lobes regardless of the integrity of pulmonary fissures. The underlying idea of the developed lobe segmentation scheme is to use piecewise planes to approximate the detected fissures. After a rotation and a global smoothing, a number of small planes were fitted using local fissures points. The local surfaces are finally combined for lobe segmentation using a quadratic B-spline weighting strategy to assure that the segmentation is smooth. The performance of the developed scheme was assessed by comparing with a manually created reference standard on a dataset of 30 lung CT examinations. These examinations covered a number of lung diseases and were selected from a large chronic obstructive pulmonary disease (COPD) dataset. The results indicate that our scheme of lobe segmentation is efficient and accurate against incomplete fissures.

  18. Anal fissure - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100154.htm Anal fissure - series—Normal anatomy To use the sharing ... rectum through which passes stool during defecation. The anal sphincter is a critical mechanism for control of ...

  19. Earth fissures and localized differential subsidence

    USGS Publications Warehouse

    Holzer, Thomas L.; Pampeyan, Earl H.

    1981-01-01

    Long linear tension cracks associated with declining groundwater levels at four sites in subsiding areas in south-central Arizona, Fremont Valley, California, and Las Vegas Valley, Nevada, occur near points of maximum convex-upward curvature in subsidence profiles oriented perpendicular to the cracks. Profiles are based on repeated precise vertical control surveys of lines of closely spaced bench marks. Association of these fissures with zones of localized differential subsidence indicates that linear earth fissures are caused by horizontal tensile strains probably resulting from localized differential compaction. Horizontal tensile strains across the fissures at the point of maximum convex-upward curvature, ranging from approximately 100 to 700 microstrains (0.01 to 0.07% per year), were indicated based on measurements with a tape or electronic distance meter.

  20. Effect of laser and air abrasion pretreatment on the microleakage of a fissure sealant applied with conventional and self etch adhesives.

    PubMed

    Tirali, R E; Celik, C; Arhun, N; Berk, G; Cehreli, S B

    2013-01-01

    The purpose of this study was to investigate the effects of different pretreatment protocols along with different bonding agents on the microleakage of a fissure sealant material. A total of 144 freshly extracted noncarious human third molars were used The teeth were randomly assigned into three groups with respect to the pretreatment protocol employed: A. Air Abrasion B. Er,Cr:YSGG laser C. No pretreatment (Control). In each group specimens were further subjected to one of the following procedures before application of the sealant: 1. %36 Phosphoric acid-etch (AE) (DeTrey Conditioner 36/Denstply, UK) 2.AE+Prime&Bond NT (Dentsply, UK) 3. Clearfil S3 Bond (Kuraray, Japan) 4. Clearfil SE Bond (Kuraray, Japan). All teeth were sealed with the same fissure sealant material (Conseal F/SDI, Australia). Sealed teeth were further subjected to thermocycling, dye penetration test, sectioning and quantitative image analysis. Statistical evaluation of the microleakage data was performed with two way independent ANOVA and multiple comparisons test at p = 0.05. For qualitative evaluation 2 samples from each group were examined under Scanning Electron Microscopy. Microleakage was affected by both the type of pretreatment and the subsequent bonding protocols employed (p < 0.05). Overall, the highest (Mean = 0.36 mm) and lowest (Mean = 0.06 mm) microleakage values were observed in samples with unpretreated enamel sealed by S3+Conseal F and samples with laser pretreated enamel sealed by Acid Etch+Prime&-Bond+Conseal F protocols, respectively (p < 0.05). In the acid-etch group samples pretreated with laser yielded in slightly lower microleakage scores when compared with unpretreated samples and samples pretreated with air abrasion but the statistical significance was not important (p = 0,179). Similarly, when bonding agent is applied following acid-etching procedure, microleakage scores were not affected from pretreatment protocol (p = 0,615) (intact enamel/laser or air-abrasion). For

  1. [Fissures in biliary calculi. Personal contribution (author's transl)].

    PubMed

    Nano, M; Potenzoni, F; Camandona, M; Casalegno, P A

    1979-04-01

    In a series of 70 patients suffering from biliary lithiasis, the roentgenologic findings of fissures in the calculi was observed in 5 cases examined by means of cholecystography and in 7 cases who underwent cholangiocholecystography. Fissures were demonstrated 11 times in calculi after surgery. The "Mercedes-Benz" sign was never observed at the abdominal examination without contrast medium. The presence of fissures may be an additional sign in the radiologic diagnosis of biliary calculi, but its value is not determinant.

  2. Research on Integrated Geophysics Detect Potential Ground Fissure in City

    NASA Astrophysics Data System (ADS)

    Qian, R.

    2017-12-01

    North China confined aquifer lied 70 to 200 meters below the earth's surface has been exploited for several decades, which resulted in confined water table declining and has generated a mass of ground fissure. Some of them has reached the surface and the other is developing. As it is very difficult to stop the ground fissure coming into being, measures of avoiding are often taken. It brings great potential risk to urban architecture and municipal engineering. It is very important to find out specific distribution and characteristic of potential ground fissure in city with high resolution. The ground fissure is concealed, therefor, geophysical method is an important technology to detecting concealed ground fissure. However, it is very difficult to detect the characteristics of the superficial part of ground fissure directly, as it lies dozens of meters below and has only scores of centimeters fault displacement. This paper studies applied ground penetration radar, surface wave and shallow refleciton seismic to detect ground fissure. It sets up model of surface by taking advantage of high resolution of ground penetrating radar data, constrains Reilay wave inversion and improves its resolution. The high resolution reflection seismic is good at detecting the geology structure. The data processing and interpretation technique is developmented to avoid the pitfall and improve the aliability of the rusult. The experiment has been conducted in Shunyi District, Beijing in 2016. 5 lines were settled to collect data of integrated geophysical method. Development zone of concealed ground fissure was found and its ultra shallow layer location was detected by ground penetrating radar. A trial trench of 6 meters in depth was dug and obvious ground fissure development was found. Its upper end was 1.5 meters beneath the earth's surface with displacement of 0.3 meters. The favorable effect of this detection has provided a new way for detecting ground fissure in cities of China, such

  3. A Computational Geometry Approach to Automated Pulmonary Fissure Segmentation in CT Examinations

    PubMed Central

    Pu, Jiantao; Leader, Joseph K; Zheng, Bin; Knollmann, Friedrich; Fuhrman, Carl; Sciurba, Frank C; Gur, David

    2010-01-01

    Identification of pulmonary fissures, which form the boundaries between the lobes in the lungs, may be useful during clinical interpretation of CT examinations to assess the early presence and characterization of manifestation of several lung diseases. Motivated by the unique nature of the surface shape of pulmonary fissures in three-dimensional space, we developed a new automated scheme using computational geometry methods to detect and segment fissures depicted on CT images. After a geometric modeling of the lung volume using the Marching Cube Algorithm, Laplacian smoothing is applied iteratively to enhance pulmonary fissures by depressing non-fissure structures while smoothing the surfaces of lung fissures. Next, an Extended Gaussian Image based procedure is used to locate the fissures in a statistical manner that approximates the fissures using a set of plane “patches.” This approach has several advantages such as independence of anatomic knowledge of the lung structure except the surface shape of fissures, limited sensitivity to other lung structures, and ease of implementation. The scheme performance was evaluated by two experienced thoracic radiologists using a set of 100 images (slices) randomly selected from 10 screening CT examinations. In this preliminary evaluation 98.7% and 94.9% of scheme segmented fissure voxels are within 2 mm of the fissures marked independently by two radiologists in the testing image dataset. Using the scheme detected fissures as reference, 89.4% and 90.1% of manually marked fissure points have distance ≤ 2 mm to the reference suggesting a possible under-segmentation of the scheme. The case-based RMS (root-mean-square) distances (“errors”) between our scheme and the radiologist ranged from 1.48±0.92 to 2.04±3.88 mm. The discrepancy of fissure detection results between the automated scheme and either radiologist is smaller in this dataset than the inter-reader variability. PMID:19272987

  4. Using occlusal wear information and finite element analysis to investigate stress distributions in human molars

    PubMed Central

    Benazzi, Stefano; Kullmer, Ottmar; Grosse, Ian R; Weber, Gerhard W

    2011-01-01

    Simulations based on finite element analysis (FEA) have attracted increasing interest in dentistry and dental anthropology for evaluating the stress and strain distribution in teeth under occlusal loading conditions. Nonetheless, FEA is usually applied without considering changes in contacts between antagonistic teeth during the occlusal power stroke. In this contribution we show how occlusal information can be used to investigate the stress distribution with 3D FEA in lower first molars (M1). The antagonistic crowns M1 and P2–M1 of two dried modern human skulls were scanned by μCT in maximum intercuspation (centric occlusion) contact. A virtual analysis of the occlusal power stroke between M1 and P2–M1 was carried out in the Occlusal Fingerprint Analyser (OFA) software, and the occlusal trajectory path was recorded, while contact areas per time-step were visualized and quantified. Stress distribution of the M1 in selected occlusal stages were analyzed in strand7, considering occlusal information taken from OFA results for individual loading direction and loading area. Our FEA results show that the stress pattern changes considerably during the power stroke, suggesting that wear facets have a crucial influence on the distribution of stress on the whole tooth. Grooves and fissures on the occlusal surface are seen as critical locations, as tensile stresses are concentrated at these features. Properly accounting for the power stroke kinematics of occluding teeth results in quite different results (less tensile stresses in the crown) than usual loading scenarios based on parallel forces to the long axis of the tooth. This leads to the conclusion that functional studies considering kinematics of teeth are important to understand biomechanics and interpret morphological adaptation of teeth. PMID:21615398

  5. Who discovered the sylvian fissure?

    PubMed

    Collice, Massimo; Collice, Rosa; Riva, Alessandro

    2008-10-01

    Cerebral convolutions were unknown until the 17th century. A constant sulcus was not recognized until the mid-1600s; it was named "the fissure of Sylvius," after the person who had always been considered as the one who discovered it. It is commonly asserted that the first description of the lateral scissure was made by Caspar Bartholin, who attributed its discovery to Sylvius. However, this was not actually the case, as Caspar Bartholin died in 1629, whereas Sylvius started studying medicine in 1632. The description could have been made either by Caspar Bartholin's son Thomas or by Sylvius himself. Irrespective of the description's author, the key to the history of the lateral fissure is that it was first identified by Fabrici d'Acquapendente in 1600, 40 years before Sylvius' description. In one of the 300 colored plates (Tabulae Pictae) by Fabrici, the lateral fissure is perfectly depicted, as are the temporal convolutions. Therefore, even if it was an accidental discovery, Fabrici should be the one noted as having discovered the fissure. This article ends with a short history of the plates. They were painted in oil on paper and were thought to further a great work, the Theatrum Totius Animalis Fabricae, which was begun in 1591 and never completed or published. Only the colored illustrations of this project remain. These plates were forgotten for more than 200 years, until they were rediscovered by Giuseppe Sterzi in 1909. They are among the best examples of anatomic iconography in terms of innovation, accuracy, and artistic accomplishment.

  6. Macroscopic Anatomy of the Saimaa Ringed Seal (Phoca hispida saimensis) Lower Respiratory Tract.

    PubMed

    Laakkonen, Juha; Jernvall, Jukka

    2016-04-01

    We studied the macroscopic anatomy of the lower respiratory tract of the endangered Saimaa ringed seal (Phoca hispida saimensis). Examination of one adult and one young individual found dead showed that trachea had 85 and 86 complete cartilage rings. The adjacent cartilages exhibited very few random anastomoses. There was variation in the confirmation of the trachea between the cranial and caudal part of the trachea. The right lung was divided by partly incomplete inter-lobar fissures into cranial, middle, caudal, and accessory lobes. The left lung consisted of cranial, middle, and caudal lobes. The lungs were characterized by a high amount of interlobular connective tissue. Silicone casts were prepared of the two specimens to visualize the tracheobronchial branching which was similar to that of marine ringed seals but in the Saimaa ringed seal the right middle lobar bronchus originated at the same level as the accessory lobar bronchus. © 2016 Wiley Periodicals, Inc.

  7. Influence of stains on lesion contrast in the pits and fissures of tooth occlusal surfaces from 800-1600-nm

    NASA Astrophysics Data System (ADS)

    Almaz, Elias C.; Simon, Jacob C.; Fried, Daniel; Darling, Cynthia L.

    2016-02-01

    For over one hundred years, x-rays have served as a cornerstone of dentistry. Dental radiographic imaging technologies have constantly improved, however, detecting occlusal lesions remains as one of the greatest challenges due to the low sensitivity of radiographs and the overlap of enamel. Once detected, occlusal lesions have penetrated far into the dentin, necessitating invasive restorative treatment. The adoption of near-infrared (NIR) systems in dentistry introduces the potential for early detection of occlusal lesions. Commercially available NIR systems for intra-oral applications currently operate near 800-nm; however, extrinsic stains may interfere with the detection of demineralization of the underlying enamel surface. Higher wavelengths such as 1300-nm render stains nearly transparent and enhances the contrast of sound enamel to demineralized enamel. This novel finding promotes minimally invasive dentistry and allows oral health professionals the ability to detect, image, track, and monitor early lesions without repeated exposure to ionizing radiation nor invasive treatment.

  8. Influence of stains on lesion contrast in the pits and fissures of tooth occlusal surfaces from 800-1600-nm.

    PubMed

    Almaz, Elias C; Simon, Jacob C; Fried, Daniel; Darling, Cynthia L

    2016-02-13

    For over one hundred years, x-rays have served as a cornerstone of dentistry. Dental radiographic imaging technologies have constantly improved, however, detecting occlusal lesions remains as one of the greatest challenges due to the low sensitivity of radiographs and the overlap of enamel. Once detected, occlusal lesions have penetrated far into the dentin, necessitating invasive restorative treatment. The adoption of near-infrared (NIR) systems in dentistry introduces the potential for early detection of occlusal lesions. Commercially available NIR systems for intra-oral applications currently operate near 800-nm; however, extrinsic stains may interfere with the detection of demineralization of the underlying enamel surface. Higher wavelengths such as 1300-nm render stains nearly transparent and enhances the contrast of sound enamel to demineralized enamel. This novel finding promotes minimally invasive dentistry and allows oral health professionals the ability to detect, image, track, and monitor early lesions without repeated exposure to ionizing radiation nor invasive treatment.

  9. Fine Mapping and Introgressing a Fissure Resistance Locus

    USDA-ARS?s Scientific Manuscript database

    Rice (Oryza sativa L.) kernel fissuring is a major concern of both rice producers and millers. Fissures are small cracks in rice kernels that increase breakage among kernels when transported or milled, which decrease the value of processed rice. This study employed molecular gene tagging methods to ...

  10. Corrosion sealing of amalgam restorations in vitro.

    PubMed

    Mahler, David B; Pham, Bao V; Adey, Jerry D

    2009-01-01

    Amalgam restorations, when first placed, have been shown to exhibit a gap at the amalgam/tooth interface. With time in service, this gap fills with corrosion products that have the potential to "seal" the restoration. With the advent of high-copper, more corrosion-resistant amalgams, there has been concern that the time required to create this seal would be increased significantly when compared with low-copper traditional amalgams. The current study was designed to address this concern. Amalgam was condensed into a MACOR mold, simulating a Class I cavity form and then immersed into a 1.0% NaCl solution to simulate oral conditions. Using an air pressure test, the sealing was monitored over time. The results showed that the sealing was influenced by the size of the initial gap prior to immersion as well as corrosion resistance of the amalgam and that a corrosion-resistant amalgam with a small initial gap size can seal as quickly as a corrosion-prone amalgam. Therefore, it is not possible to predict sealing behavior based on corrosion resistance, alone. Furthermore, the presence of zinc in the amalgam alloy has been shown to result in the formation of zinc corrosion products in the amalgam/mold margin, which contributes to more rapid sealing. Analysis of a tooth extracted after 16 years of clinical service that had been restored with an amalgam-containing zinc was also shown to contain zinc corrosion products in the occlusal marginal area. This could explain the reported reduction in marginal fracture of clinically placed amalgam restorations made from zinc-containing alloys.

  11. Ultrasound Fissure Observation: Assessment of Lung by Pleural-Hub Affiliates.

    PubMed

    Zanforlin, Alessandro; Livi, Vanina; Santoriello, Carlo; Ceruti, Paolo; Trigiani, Marco; Valerio, Manlio; Perani, Cristiano; Carlucci, Paolo; Palmiotti, Antonio; Marchetti, Giampietro

    2018-02-22

    Lung ultrasound examination is becoming an even more important part of pulmonologists' clinical routine. As indicated in the literature, the coordinates of any findings on lung parenchyma are based on surface landmarks or conventional quadrants. In our experience we have noticed that lung fissures are clearly detectable as interruptions of the pleural line, but this has never been investigated previously. The aim of this study was to evaluate whether lung fissures are detectable under normal conditions in routine clinical practice. Ten operators were enrolled from Pleural-Hub, a scientific discussion group. After compiling a prestudy survey to investigate whether they had observed fissures previously, they were asked to note if the following fissures were detectable: posterior right (PR) and left (PL), lateral right (LR) and left (LL), anterior right (AR), and anterolateral left (AL). Enrollment was competitive, aiming to reach 100 case subjects. We found that general fissure detection was 61.3%, in particular: PR, 59%; LR, 75%; AR, 69%; PL, 45%; LL, 64%; AL, 56%. Single operators yielded different detection rates ranging from 90% to 25%, showing strong operator dependency. Before being made aware of general results operators indicated operator's skill and rib shadow artifacts as the principal factors affecting fissure detection. Lung fissures may be detected with ultrasound once adequate training is provided. This may allow the clinician a more precise anatomical delineation of pathology identified by lung ultrasound. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  12. Lateral internal sphincterotomy for surgically recurrent chronic anal fissure.

    PubMed

    Liang, Jennifer; Church, James M

    2015-10-01

    Lateral internal sphincterotomy cures chronic anal fissure by preventing internal sphincter hypertonia. However, cutting sphincter predisposes to sphincter dysfunction, manifests as incontinence of gas, liquid, or stool. Surgeons, therefore, can be too cautious in its use, making ineffective superficial incisions or avoiding the operation altogether. This study is designed to confirm the role of redo lateral internal sphincterotomy in the treatment of surgically recurrent chronic anal fissure. Patients undergoing repeat lateral internal sphincterotomy for surgically recurrent chronic anal fissure were accessed from a prospectively maintained database. Chronicity was defined by symptoms persisting more than 3 weeks. Contralateral sphincterotomy was performed with electrocautery through a stab incision over the intersphincteric plane. The length of sphincter division was the same as the length of the fissure. Phone questionnaire was administered and fecal continence was assessed by modified Cleveland Clinic Incontinence Score. Patients were asked to rank their overall satisfaction with the operation, and pre- and postoperative quality of life. There were 57 patients, 24 women and 33 men; mean age was 47.9 ± 14.8 years. Mean follow-up was 12.5 ± 4.2 years (range 6.2 to 25.2 years). Presenting symptoms included pain (100%), bleeding (80%), pruritus ani (39%), constipation (26%), and diarrhea. Fifty patients (90%) presented with 1 fissure, and 40 were posterior. Most procedures were performed on an outpatient basis. Fissure healing rate was 98%, and 2 patients (4%) developed minor incontinence postoperatively (one of gas, the other, gas and seepage). Overall satisfaction was 9.7 ± .9 out of 10 with a significant improvement in the quality of life from 5.7 ± 2.4 out of 10 to 9.3 ± 1.4 out of 10 (P < .001). Judicious repeat lateral sphincterotomy cures recurrent chronic fissures with minimal risk of incontinence. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Surface anatomy of the pulmonary fissures determined by high-resolution computed tomography.

    PubMed

    Heřmanová, Zuzana; Ctvrtlík, Filip; Heřman, Miroslav

    2012-10-01

    The aim of our study was to describe the surface anatomy of the interlobar fissures using volumetric thin-section high-resolution computed tomography (HRCT). Retrospective assessment of HRCT examinations of 250 patients was performed. The localization of the oblique fissures was marked at three sites: posteriorly at its most superior medial limit, laterally in the midaxillary line, and inferiorly at the junction of the middle and lateral thirds of the hemithorax; posteriorly and laterally, this was to the nearest rib whilst inferiorly the position was described in relation to the diaphragm or chest wall. The localization of the horizontal fissure was marked anteriorly in relation to the nearest rib (or costal cartilage) and posteriorly where it intersected with the oblique fissure (superior, middle, or inferior third). Shapes of the fissures and differences between inspiration and expiration were also documented. Descriptive statistics were used to report the most frequent positions. The most frequent localization of the oblique fissure on the left side was posteriorly at the fourth rib (45%), laterally at the sixth rib (52%), and inferiorly in the anterior third of the hemidiaphragm (60%). The right oblique fissure was located posteriorly at the fifth rib (50%), laterally at the sixth rib (50%), and inferiorly in the anterior third of the hemidiaphragm (71%). The horizontal fissure most commonly originated in the middle third of the oblique fissure (61%) and met the anterior thoracic wall at the level of the fourth rib (51%). The most frequent shape of the left oblique fissure was linear (78%), whereas S-shaped and linear configurations (28% each) were most frequent on the right. No difference was found in the surface markings of the fissures between inspiration and expiration in 90% of cases. The considerable individual variation in the position and shape of the interlobar fissures helps to explain the variable descriptions of their surface anatomy in the

  14. Selection for fissure resistance now made possible in early breeding generations

    USDA-ARS?s Scientific Manuscript database

    Rice kernel fissuring is one of the leading causes of milling yield losses. Any reduction in fissuring can result in direct increases in yield and profit for both producers and millers. While most U.S. rice varieties yield around 55% head rice, the fissure-resistant varieties ‘Cypress’, ‘Saber’ an...

  15. Infrasound from the 2007 fissure eruptions of Kīlauea Volcano, Hawai'i

    NASA Astrophysics Data System (ADS)

    Fee, David; Garces, Milton; Orr, Tim; Poland, Mike

    2011-03-01

    Varied acoustic signals were recorded at Kīlauea Volcano in mid-2007, coincident with dramatic changes in the volcano's activity. Prior to this time period, Pu'u 'Ō'ō crater produced near-continuous infrasonic tremor and was the primary source of degassing and lava effusion at Kīlauea. Collapse and draining of Pu'u 'Ō'ō crater in mid-June produced impulsive infrasonic signals and fluctuations in infrasonic tremor. Fissure eruptions on 19 June and 21 July were clearly located spatially and temporally using infrasound arrays. The 19 June eruption from a fissure approximately mid-way between Kīlauea's summit and Pu'u 'Ō'ō produced infrasound for ˜30 minutes—the only observed geophysical signal associated with the fissure opening. The infrasound signal from the 21 July eruption just east of Pu'u 'Ō'ō shows a clear azimuthal progression over time, indicative of fissure propagation over 12.9 hours. The total fissure propagation rate is relatively slow at 164 m/hr, although the fissure system ruptured discontinuously. Individual fissure rupture times are estimated using the acoustic data combined with visual observations.

  16. Infrasound from the 2007 fissure eruptions of Kīlauea Volcano, Hawai'i

    USGS Publications Warehouse

    Fee, D.; Garces, M.; Orr, T.; Poland, M.

    2011-01-01

    Varied acoustic signals were recorded at Kīlauea Volcano in mid-2007, coincident with dramatic changes in the volcano's activity. Prior to this time period, Pu'u 'Ō'ō crater produced near-continuous infrasonic tremor and was the primary source of degassing and lava effusion at Kīlauea. Collapse and draining of Pu'u 'Ō'ō crater in mid-June produced impulsive infrasonic signals and fluctuations in infrasonic tremor. Fissure eruptions on 19 June and 21 July were clearly located spatially and temporally using infrasound arrays. The 19 June eruption from a fissure approximately mid-way between Kīlauea's summit and Pu'u 'O'o produced infrasound for ~30 minutes-the only observed geophysical signal associated with the fissure opening. The infrasound signal from the 21 July eruption just east of Pu'u 'Ō'ō shows a clear azimuthal progression over time, indicative of fissure propagation over 12.9 hours. The total fissure propagation rate is relatively slow at 164 m/hr, although the fissure system ruptured discontinuously. Individual fissure rupture times are estimated using the acoustic data combined with visual observations.

  17. Engineering a robotic approach to mapping exposed volcanic fissures

    NASA Astrophysics Data System (ADS)

    Parcheta, C. E.; Parness, A.; Mitchell, K. L.

    2014-12-01

    Field geology provides a framework for advanced computer models and theoretical calculations of volcanic systems. Some field terrains, though, are poorly preserved or accessible, making documentation, quantification, and investigation impossible. Over 200 volcanologists at the 2012 Kona Chapman Conference on volcanology agreed that and important step forward in the field over the next 100 years should address the realistic size and shape of volcanic conduits. The 1969 Mauna Ulu eruption of Kīlauea provides a unique opportunity to document volcanic fissure conduits, thus, we have an ideal location to begin addressing this topic and provide data on these geometries. Exposed fissures can be mapped with robotics using machine vision. In order to test the hypothesis that fissures have irregularities with depth that will influence their fluid dynamical behavior, we must first map the fissure vents and shallow conduit to deci- or centimeter scale. We have designed, constructed, and field-tested the first version of a robotic device that will image an exposed volcanic fissure in three dimensions. The design phase included three steps: 1) create the payload harness and protective shell to prevent damage to the electronics and robot, 2) construct a circuit board to have the electronics communicate with a surface-based computer, and 3) prototype wheel shapes that can handle a variety of volcanic rock textures. The robot's mechanical parts were built using 3d printing, milling, casting and laser cutting techniques, and the electronics were assembled from off the shelf components. The testing phase took place at Mauna Ulu, Kīlauea, Hawai'i, from May 5 - 9, 2014. Many valuable design lessons were learned during the week, and the first ever 3D map from inside a volcanic fissure were successfully collected. Three vents had between 25% and 95% of their internal surfaces imaged. A fourth location, a non-eruptive crack (possibly a fault line) had two transects imaging the textures

  18. Combined treatment approach to chronic anal fissure with associated anal fistula.

    PubMed

    FitzDowse, Andrew J; Behrenbruch, Corina C; Hayes, Ian P

    2017-12-03

    Anal fistula in association with chronic anal fissure (fissure-fistula) is infrequently described. Recognizing this association and managing both components may help prevent some treatment failures seen with chronic anal fissure. This study aims to report on the outcomes of 20 consecutive patients with fissure-fistula managed with fistulotomy and injection of botulinum A toxin. The study is a retrospective, observational study, assessing the success of symptom resolution following fistulotomy with botulinum A toxin, in patients identified as having a chronic anal fissure with associated anal fistula. The study included all patients with this condition treated with combination treatment by a single surgeon at a tertiary care hospital between January 2013 and January 2016. Twenty patients with fissure-fistula treated with fistulotomy and botulinum toxin A were identified. The median cohort age was 44 years (range 25-78), with a predominance of males (80%) and posterior fissure position (80%). The most common presenting symptoms were anal pain (70%), rectal bleeding (55%), anal discharge (35%) and anal pruritus (35%). Mean follow-up was 10.5 weeks and all patients who attended follow-up appointments reported resolution of symptoms. There were no cases of incontinence and none of the cohort required further surgical intervention for the condition. Chronic anal fissure with associated anal fistula can be successfully managed with fistulotomy and injection of botulinum toxin A. Further studies would be helpful in determining if recognition and management of the fistula component in isolation with fistulotomy is as effective as fistulotomy plus botulinum A toxin. © 2017 Royal Australasian College of Surgeons.

  19. Implications of ground-deformation measurements across earth fissures in subsidence areas in the southwestern USA

    USGS Publications Warehouse

    Holzer, Thomas L.

    2010-01-01

    Ground deformation was monitored at earth fissures in areas of land subsidence induced by groundwater extraction in the southwestern United States. The ground deformation is consistent with the mechanism that fissures are caused by horizontal strains generated by bending of overburden in response to localized differential compaction. Subsidence profiles indicated that localized differential subsidence occurred across the fissures and that maximum convex-upward curvature was at the fissure. The overall shape of the profile stayed similar with time, and maximum curvature remained stationary at the fissure. Horizontal displacements were largest near the fissure, and generally were small to negligible away from the fissure. Maximum tensile horizontal strains were at the fissure and coincided with maximum curvature in the subsidence profiles. Horizontal tensile strain continued to accumulate at fissures after they formed with rates of opening ranging from 30 to 120 microstrain/year at fissures in Arizona.

  20. Groundwater-Mining-Induced Subsidence and Earth Fissures in Cedar Valley, Southwestern Utah

    NASA Astrophysics Data System (ADS)

    Knudsen, T. R.; Inkenbrandt, P.; Lund, W. R.; Lowe, M.; Bowman, S. D.

    2014-12-01

    Groundwater pumping in excess of recharge (groundwater mining) has lowered the potentiometric surface in Cedar Valley, southwestern Utah, by as much as 114 feet since 1939. Lowering the potentiometric surface (head decline) has caused permanent compaction of fine-grained sediments of the Cedar Valley aquifer. Recently acquired interferometric synthetic aperture radar (InSAR) imagery shows that land subsidence is occurring over an ~100 square-mile area, including two pronounced subsidence bowls in the northeastern (Enoch graben) and southwestern (Quichapa Lake area) parts of the valley. A lack of accurate historical benchmark elevation data over much of the valley prevents detailed long-term quantification of subsidence. In response to the land subsidence, earth fissures have formed along the margins of the Enoch graben and north and west of Quichapa Lake. Our initial inventory of Cedar Valley fissures, which relied on aerial-photography analysis, identified 3.9 miles of fissures in 2009. With newly acquired light detection and ranging (LiDAR) coverage in 2011, we more than doubled the total length of mapped fissures to 8.3 miles. Fissures on the west side of the Enoch graben exhibit ongoing vertical surface displacement with rates as high as 1.7 inches/year. The largest Enoch-graben-west fissure has displaced street surfaces, curb and gutter, and sidewalks, and has reversed the flow direction of a sewer line in a partially developed subdivision. Several Cedar Valley fissures are closely associated with, and in some places coincident with, mapped Quaternary faults. While the majority of Cedar Valley fissures are mapped in agricultural areas, continued groundwater mining and resultant subsidence will likely cause existing fissures to lengthen and new fissures to form that may eventually impact other developed areas of the valley.

  1. The Transcription Factor Foxg1 Promotes Optic Fissure Closure in the Mouse by Suppressing Wnt8b in the Nasal Optic Stalk

    PubMed Central

    Smith, Rowena; Huang, Yu-Ting; Tian, Tian; Vojtasova, Dominika; Mesalles-Naranjo, Oscar; Price, David J.

    2017-01-01

    During vertebrate eye morphogenesis, a transient fissure forms at its inferior part, known as the optic fissure. This will gradually close, giving rise to a healthy, spherical optic cup. Failure of the optic fissure to close gives rise to an ocular disorder known as coloboma. During this developmental process, Foxg1 is expressed in the optic neuroepithelium, with highest levels of expression in the nasal optic stalk. Foxg1−/− mutant mice have microphthalmic eyes with a large ventral coloboma. We found Wnt8b expression upregulated in the Foxg1−/− optic stalk and hypothesized that, similar to what is observed in telencephalic development, Foxg1 directs development of the optic neuroepithelium through transcriptional suppression of Wnt8b. To test this, we generated Foxg1−/−;Wnt8b−/− double mutants of either sex and found that the morphology of the optic cup and stalk and the closure of the optic fissure were substantially rescued in these embryos. This rescue correlates with restored Pax2 expression in the anterior tip of the optic fissure. In addition, although we do not find evidence implicating altered proliferation in the rescue, we observe a significant increase in apoptotic cell density in Foxg1−/−;Wnt8b−/− double mutants compared with the Foxg1−/− single mutant. Upregulation of Wnt/β-catenin target molecules in the optic cup and stalk may underlie the molecular and morphological defects in the Foxg1−/− mutant. Our results show that proper optic fissure closure relies on Wnt8b suppression by Foxg1 in the nasal optic stalk to maintain balanced apoptosis and Pax2 expression in the nasal and temporal edges of the fissure. SIGNIFICANCE STATEMENT Coloboma is an ocular disorder that may result in a loss of visual acuity and accounts for ∼10% of childhood blindness. It results from errors in the sealing of the optic fissure (OF), a transient structure at the bottom of the eye. Here, we investigate the colobomatous phenotype of the

  2. Transperineal sonographic anal sphincter complex evaluation in chronic anal fissures.

    PubMed

    Bedair, Elsaid M; El Hennawy, Hany M; Moustafa, Ahmed Abdu; Meki, Gad Youssef; Bosat, Bosat Elwany

    2014-11-01

    The purpose of this study was to assess the role of transperineal sonography in assessment of pathologic changes to the anal sphincter complex in patients with chronic anal fissures. We conducted a prospective case-control study of 100 consecutive patients of any age and both sexes with chronic anal fissures who presented to a colorectal clinic between January 2012 and August 2013 (group A) and 50 healthy volunteers (group B). The most common patterns of radiologic changes to anal sphincters associated with chronic anal fissures were circumferential thickening of the anal sphincter complex in 5 patients (5%), circumferential thickening of the internal anal sphincter in 3 patients (3%), preferential thickening of the internal anal sphincter at the 6-o'clock position in 80 patients (80%) and the 12-o'clock position in 7 patients (7%), preferential thickening of the internal and external anal sphincters in 3 patients (3%), and thinning of the internal anal sphincter in 2 patients (2%). Chronic anal fissures cause differential thickening of both internal and external anal sphincters, with a trend toward increased thickness in relation to the site of the fissure. Routine preoperative transperineal sonography for patients with chronic anal fissures is recommended, and it is mandatory in high-risk patients. © 2014 by the American Institute of Ultrasound in Medicine.

  3. Sieve element occlusion (SEO) genes encode structural phloem proteins involved in wound sealing of the phloem.

    PubMed

    Ernst, Antonia M; Jekat, Stephan B; Zielonka, Sascia; Müller, Boje; Neumann, Ulla; Rüping, Boris; Twyman, Richard M; Krzyzanek, Vladislav; Prüfer, Dirk; Noll, Gundula A

    2012-07-10

    The sieve element occlusion (SEO) gene family originally was delimited to genes encoding structural components of forisomes, which are specialized crystalloid phloem proteins found solely in the Fabaceae. More recently, SEO genes discovered in various non-Fabaceae plants were proposed to encode the common phloem proteins (P-proteins) that plug sieve plates after wounding. We carried out a comprehensive characterization of two tobacco (Nicotiana tabacum) SEO genes (NtSEO). Reporter genes controlled by the NtSEO promoters were expressed specifically in immature sieve elements, and GFP-SEO fusion proteins formed parietal agglomerates in intact sieve elements as well as sieve plate plugs after wounding. NtSEO proteins with and without fluorescent protein tags formed agglomerates similar in structure to native P-protein bodies when transiently coexpressed in Nicotiana benthamiana, and the analysis of these protein complexes by electron microscopy revealed ultrastructural features resembling those of native P-proteins. NtSEO-RNA interference lines were essentially devoid of P-protein structures and lost photoassimilates more rapidly after injury than control plants, thus confirming the role of P-proteins in sieve tube sealing. We therefore provide direct evidence that SEO genes in tobacco encode P-protein subunits that affect translocation. We also found that peptides recently identified in fascicular phloem P-protein plugs from squash (Cucurbita maxima) represent cucurbit members of the SEO family. Our results therefore suggest a common evolutionary origin for P-proteins found in the sieve elements of all dicotyledonous plants and demonstrate the exceptional status of extrafascicular P-proteins in cucurbits.

  4. A Case Series of Anal Carcinoma Misdiagnosed as Idiopathic Chronic Anal Fissure.

    PubMed

    Barbeiro, Sandra; Atalaia-Martins, Catarina; Marcos, Pedro; Gonçalves, Cláudia; Cotrim, Isabel; Vasconcelos, Helena

    2017-09-01

    Chronic anal fissure is a linear ulcer in the anal canal that has not cicatrized for more than 8-12 weeks of treatment. Most anal fissures are idiopathic and are located in the posterior midline. Squamous cell carcinoma of the anus commonly presents as bleeding and anal pain. It may also present as a mass, nonhealing ulcer, itching, discharge, fecal incontinence and fistulae. Not uncommonly, small and early cancers are misdiagnosed as benign anorectal disorders like anal fissures or hemorrhoids. The clinical suspicion of squamous cell carcinoma of the anus is of paramount importance in patients with nonhealing anal fissures, fissures in atypical positions or with indurated or ulcerated anal tags and in patients with risk factors for the development of anal squamous intraepithelial lesions that are precursors of invasive anal squamous cell carcinoma. The authors present 3 cases of squamous cell carcinoma of the anus initially misdiagnosed as benign chronic anal fissure.

  5. Conditions of Fissuring in a Pumped-Faulted Aquifer System

    NASA Astrophysics Data System (ADS)

    Hernandez-Marin, M.; Burbey, T. J.

    2007-12-01

    Earth fissuring associated with subsidence from groundwater pumping is problematic in many arid-zone heavily pumped basins such as Las Vegas Valley. Long-term pumping at rates considerably greater than the natural recharge rate has stressed the heterogeneous aquifer system resulting in a complex stress-strain regime. A rigorous artificial recharge program coupled with increased surface-water importation has allowed water levels to appreciably recover, which has led to surface rebound in some localities. Nonetheless, new fissures continue to appear, particularly near basin-fill faults that behave as barriers to subsidence bowls. The purpose of this research is to develop a series of computational models to better understand the influence that structure (faults), pumping, and hydrostratigraphy has in the generation and propagation of fissures. The hydrostratigraphy of Las Vegas Valley consists of aquifers, aquitards and a relatively dry vadoze zone that may be as thick as 100m in much of the valley. Quaternary faults are typically depicted as scarps resulting from pre- pumping extensional tectonic events and are probably not responsible for the observed strain. The models developed to simulate the stress-strain and deformation processes in a faulted pumped aquifer-aquitard system of Las Vegas use the ABAQUS CAE (Complete ABAQUS Environment) software system. ABAQUS is a sophisticated engineering industry finite-element modeling package capable of simulating the complex fault- fissure system described here. A brittle failure criteria based on the tensile strength of the materials and the acting stresses (from previous models) are being used to understand how and where fissures are likely to form. , Hypothetical simulations include the role that faults and the vadose zone may play in fissure formation

  6. Monitoring of the Ground Fissure Activity Within Yuncheng Basin by Time Series Insar

    NASA Astrophysics Data System (ADS)

    Zhang, F.; Yang, C. S.; Zhao, C. Y.; Liu, R. C.

    2018-04-01

    Yuncheng area is one of the most extensive distributions of ground fissures in Shanxi basin, especially in Yanhu District of Yuncheng, the disaster of ground fissures and ground subsidence are the most serious. According to previous studies, the development and distribution of the ground fissures in this area are mainly controlled by the underlying active faults. In order to provide a better understanding of the formation mechanism, the deformation of ground fissures and its surrounding environment should be taken into consideration. In this paper, PS-InSAR technology was employed to assess the time-series ground deformation of Yuncheng ground fissures and its surrounding area with X-band TerraSAR images from 2013 to 2015. The interaction between ground fissures activity and land subsidence, groundwater, precipitation and surrounding faults will be discussed.

  7. Monitoring on Xi'an ground fissures deformation with TerraSAR-X data

    USGS Publications Warehouse

    Zhao, C.; Zhang, Q.; Zhu, W.; Lu, Z.

    2012-01-01

    Owing to the fine resolution of TerraSAR-X data provided since 2007, this paper applied 6 TerraSAR data (strip mode) during 3rd Dec. 2009 to 23rd Mar. 2010 to detect and monitor the active fissures over Xi'an region. Three themes have been designed for high precision detection and monitoring of Xi'an-Chang'an fissures, as small baseline subsets (SBAS) to test the atmospheric effects of differential interferograms pair stepwise, 2-pass differential interferogram with very short baseline perpendicular to generate the whole deformation map with 44 days interval, and finally, corner reflector (CR) technique was used to closely monitor the relative deformation time series between two CRs settled crossing two ground fissures. Results showed that TerraSAR data are a good choice for small-scale ground fissures detection and monitoring, while special considerations should be taken for their great temporal and baseline decorrelation. Secondly, ground fissures in Xi'an were mostly detected at the joint section of stable and deformable regions. Lastly, CR-InSAR had potential ability to monitor relative deformation crossing fissures with millimeter precision.

  8. Automatic segmentation of pulmonary fissures in x-ray CT images using anatomic guidance

    NASA Astrophysics Data System (ADS)

    Ukil, Soumik; Sonka, Milan; Reinhardt, Joseph M.

    2006-03-01

    The pulmonary lobes are the five distinct anatomic divisions of the human lungs. The physical boundaries between the lobes are called the lobar fissures. Detection of lobar fissure positions in pulmonary X-ray CT images is of increasing interest for the early detection of pathologies, and also for the regional functional analysis of the lungs. We have developed a two-step automatic method for the accurate segmentation of the three pulmonary fissures. In the first step, an approximation of the actual fissure locations is made using a 3-D watershed transform on the distance map of the segmented vasculature. Information from the anatomically labeled human airway tree is used to guide the watershed segmentation. These approximate fissure boundaries are then used to define the region of interest (ROI) for a more exact 3-D graph search to locate the fissures. Within the ROI the fissures are enhanced by computing a ridgeness measure, and this is used as the cost function for the graph search. The fissures are detected as the optimal surface within the graph defined by the cost function, which is computed by transforming the problem to the problem of finding a minimum s-t cut on a derived graph. The accuracy of the lobar borders is assessed by comparing the automatic results to manually traced lobe segments. The mean distance error between manually traced and computer detected left oblique, right oblique and right horizontal fissures is 2.3 +/- 0.8 mm, 2.3 +/- 0.7 mm and 1.0 +/- 0.1 mm, respectively.

  9. Morbidity associated with treatment of chronic anal fissure

    PubMed Central

    Latif, Ansar; Ansar, Anila; Butt, Muhammad Qasim

    2013-01-01

    Objective: To assess the effectiveness of different modes of treatment of chronic anal fissure as regards improvement of symptoms and complications. Methods: This prospective study included 129 consecutive patients with chronic anal fissures presented to the Surgical Outpatients’ Department of Islam Teaching Hospital Sialkot, Pakistan; from September 2010 to November 2012. Patients were distributed in three groups. In “OBG group”, patients had attended Gynae/Obs OPD and got treated and were then referred to surgical OPD for failure of treatment or recurrence. Patients who presented with history of treatment by GPs were included in “GP Group” “SGR Group” included those who directly reported to surgical OPD for treatment. Patients were managed both pharmacologically as OPD patients and surgically as admitted patients. Patients were instructed to apply small amounts of 0.2% GTN paste in soft white paraffin, to the anoderm with finger tips three times a day. Patients were evaluated at two-week intervals and at each visit the symptoms control, adverse effects and fissure status were recorded. If there was symptomatic relief or the fissure healing was in progress, the treatment was continued for a total duration of eight weeks. Operated patients were nursed in wards after surgery i.e Internal Anal Sphicterotomy. They were advised to report to OPD weekly for one month or earlier if they experienced any symptoms suggestive of complications. Patients were declared cured in case of complete symptomatic relief with fissure healing. Success, failure and associated problems were recorded and analysed to get results. Results:This study included 129 patients who could be followed up for a minimum of three months. These patients were referred by gynaecologist i.e. 22 (17%) for treatment failure while 5 patients with wrong diagnosis were not included in statistical analysis; similarly 41 (32%) patients were referred by general practitioners and 9 patients with wrong

  10. The effect of normal pulsed Nd-YAG laser irradiation on pits and fissures in human teeth.

    PubMed

    Bahar, A; Tagomori, S

    1994-01-01

    The effects of normal pulsed Nd-YAG laser irradiation on the acid resistance of human dental enamel of pits and fissures, the cleaning of the pit and fissure contents and fluoride uptake into deep pits and fissures were examined. The acid resistance of the pit and fissure enamel was evaluated by the amount of dissolved calcium per square millimeter of the surface area. The pit and fissure enamel treated with laser irradiation obtained an acid resistance 30% higher than that of the unlased controls. The cleaning effect of laser irradiation on the pit and fissure contents was compared with chemicomechanical and mechanical methods. The laser irradiation was found to clean the pits and fissures to a greater depth without alterating the shape of pits and fissures, compared with the other two methods. The distribution of calcium, phosphorus and fluoride in the enamel of the pits and fissures was then measured by electron probe microanalyzer. At the entrance and in the deep part of the pits and fissures, the fluoride content of the enamel treated with acidulated phosphate fluoride after laser irradiation was higher than that of the enamel treated with acidulated phosphate fluoride alone. These results thus suggest that Nd-YAG laser irradiation might be effective in increasing the acid resistance of the pit and fissure enamel, while removing the pit and fissure debris contents and increasing the fluoride uptake into the pit and fissure enamel.

  11. [Diagnosis and surgical treatment of intraparenchymal sylvian fissure meningioma].

    PubMed

    Zheng, Jian; Wang, Shuo; Zhao, Ji-Zong; Cao, Yong

    2009-09-08

    To describe the characteristics of patients diagnosed with intraparenchymal sylvian meningioma at our department. A retrospective review was performed over 5 patients with intraparenchymal sylvian fissure meningioma confirmed by histopathology and receiving treatment at our department during January 1997 to September 2008. The mean age was 19.4 years old and there were 3 males and 2 females. On CT scanning, intraparenchymal sylvian meningioma was iso- or slightly hyper-dense masses. On MR imaging, tumors showed iso- or hypo- intense signal on T1WI and hyperintense signal on T2WI. After contrast enhancement, T1-weighted images revealed well-demarcated enhancing masses and intimately associated with the middle cerebral artery and its branches in the sylvian fissure. All the patients underwent craniotomy. As a rare disease with radiographic characteristics similar to those of general meningiomas, intraparenchymal sylvian fissure meningioma does not adhere to the dura matter but adhere to or even encase the middle cerebral artery and its branches in the sylvian fissure. All of the above have differential values. During the surgical procedures, a proper handling of tumor and encompassed main trunk of middle cerebral artery and its branches is crucial to patient prognosis.

  12. Pit and fissure sealants for preventing dental decay in permanent teeth.

    PubMed

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya; Nordblad, Anne; Mäkelä, Marjukka; Worthington, Helen V

    2017-07-31

    Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries in children and adolescents compared to no sealants. Effectiveness may, however, be related to caries incidence level of the population. This is an update of a review published in 2004, 2008 and 2013. To compare the effects of different types of fissure sealants in preventing caries in occlusal surfaces of permanent teeth in children and adolescents. Cochrane Oral Health's Information Specialist searched: Cochrane Oral Health's Trials Register (to 3 August 2016), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2016, Issue 7), MEDLINE Ovid (1946 to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Randomised controlled trials (RCTs) comparing sealants with no sealant or a different type of sealant material for preventing caries of occlusal surfaces of premolar or molar teeth in children and adolescents aged up to 20 years. Studies required at least 12 months follow-up. We excluded studies that compared compomers to resins/composites. Two review authors independently screened search results, extracted data and assessed risk of bias of included studies. We presented outcomes for caries or no caries on occlusal surfaces of permanent molar teeth as odds ratio (OR) or risk ratio (RR). We used mean difference (MD) for mean caries increment. All measures were presented with 95% confidence intervals (CI). We conducted meta-analyses using a random-effects model for comparisons where there were more than three trials; otherwise we used the fixed

  13. A robotic approach to mapping post-eruptive volcanic fissure conduits

    NASA Astrophysics Data System (ADS)

    Parcheta, Carolyn E.; Pavlov, Catherine A.; Wiltsie, Nicholas; Carpenter, Kalind C.; Nash, Jeremy; Parness, Aaron; Mitchell, Karl L.

    2016-06-01

    VolcanoBot was developed to map volcanic vents and their underlying conduit systems, which are rarely preserved and generally inaccessible to human exploration. It uses a PrimeSense Carmine 1.09 sensor for mapping and carries an IR temperature sensor, analog distance sensor, and an inertial measurement unit (IMU) inside a protective shell. The first field test succeeded in collecting valuable scientific data but revealed several needed improvements, including more rugged cable connections and mechanical couplers, increased ground clearance, and higher-torque motors for uphill mobility. The second field test significantly improved on all of these aspects but it traded electrical ruggedness for reduced data collection speed. Data collected by the VolcanoBots, while intermittent, yield the first insights into the cm-scale geometry of volcanic fissures at depths of up to 25 m. VolcanoBot was deployed at the 1969 Mauna Ulu fissure system on Kīlauea volcano in Hawai'i. It collected first-of-its-kind data from inside the fissure system. We hypothesized that 1) fissure sinuosity should decrease with depth, 2) irregularity should be persistent with depth, 3) any blockages in the conduit should occur at the narrowest points, and 4) the fissure should narrow with depth until it is too narrow for VolcanoBot to pass or is plugged with solidified lava. Our field campaigns did not span enough lateral or vertical area to test sinuosity. The preliminary data indicate that 1) there were many irregularities along fissures at depth, 2) blockages occurred, but not at obviously narrow locations, and 3) the conduit width remained a consistent 0.4-0.5 m for most of the upper 10 m that we analyzed.

  14. An Investigation of the Morphology of the Petrotympanic Fissure Using Cone-Beam Computed Tomography

    PubMed Central

    Syriopoulos, Konstantinos; Sens, Rogier L.; Politis, Constantinus

    2018-01-01

    ABSTRACT Objectives The purpose of the present study was: a) to examine the visibility and morphology of the petrotympanic fissure on cone-beam computed tomography images, and b) to investigate whether the petrotympanic fissure morphology is significantly affected by gender and age, or not. Material and Methods Using Newtom VGi (QR Verona, Italy), 106 cone-beam computed tomography examinations (212 temporomandibular joint areas) of both genders were retrospectively and randomly selected. Two observers examined the images and subsequently classified by consensus the petrotympanic fissure morphology into the following three types: type 1 - widely open; type 2 - narrow middle; type 3 - very narrow/closed. Results The petrotympanic fissure morphology was assessed as type 1, type 2, and type 3 in 85 (40.1%), 72 (34.0%), and 55 (25.9%) cases, respectively. No significant difference was found between left and right petrotympanic fissure morphology (Kappa = 0.37; P < 0.001). Furthermore, no significant difference was found between genders, specifically P = 0.264 and P = 0.211 for the right and left petrotympanic fissure morphology, respectively. However, the ordinal logistic regression analysis showed that males tend to have narrower petrotympanic fissures, in particular OR = 1.58 for right and OR = 1.5 for left petrotympanic fissure. Conclusions The current study lends support to the conclusion that an enhanced multi-planar cone-beam computed tomography yields a clear depiction of the petrotympanic fissure's morphological characteristics. We have found that the morphology is neither gender nor age-related. PMID:29707183

  15. An Investigation of the Morphology of the Petrotympanic Fissure Using Cone-Beam Computed Tomography.

    PubMed

    Damaskos, Spyros; Syriopoulos, Konstantinos; Sens, Rogier L; Politis, Constantinus

    2018-01-01

    The purpose of the present study was: a) to examine the visibility and morphology of the petrotympanic fissure on cone-beam computed tomography images, and b) to investigate whether the petrotympanic fissure morphology is significantly affected by gender and age, or not. Using Newtom VGi (QR Verona, Italy), 106 cone-beam computed tomography examinations (212 temporomandibular joint areas) of both genders were retrospectively and randomly selected. Two observers examined the images and subsequently classified by consensus the petrotympanic fissure morphology into the following three types: type 1 - widely open; type 2 - narrow middle; type 3 - very narrow/closed. The petrotympanic fissure morphology was assessed as type 1, type 2, and type 3 in 85 (40.1%), 72 (34.0%), and 55 (25.9%) cases, respectively. No significant difference was found between left and right petrotympanic fissure morphology (Kappa = 0.37; P < 0.001). Furthermore, no significant difference was found between genders, specifically P = 0.264 and P = 0.211 for the right and left petrotympanic fissure morphology, respectively. However, the ordinal logistic regression analysis showed that males tend to have narrower petrotympanic fissures, in particular OR = 1.58 for right and OR = 1.5 for left petrotympanic fissure. The current study lends support to the conclusion that an enhanced multi-planar cone-beam computed tomography yields a clear depiction of the petrotympanic fissure's morphological characteristics. We have found that the morphology is neither gender nor age-related.

  16. Risk factors special to eastern culture for the development of anal fissure.

    PubMed

    Erel, Serap; Adahan, Didem; Kismet, Kemal; Caylan, Ayse; Tanrikulu, Yusuf; Akkus, Mehmet Ali

    2009-01-01

    To reveal the effect of diet, bowel functions and toilet habits on the development of anal fissure. One hundred patients complaining of anal fissure were included to the case group; and one hundred age- and gender-matched patients referred for other reasons except for anorectal complaints were included to the control group. The information was obtained by face to face interviews using questionnaires. Statistically significant differences were found in coffee, fruit, and meat consumption between the groups. The patients suffering from anal fissure avoided paprika consumption. The rate of anal fissure incidence was higher in squat toilet users. This study is the first study which evaluates the risk factors such as paprika consumption and squat toilet usage that are specific to Eastern culture. Further studies including large numbers of population are needed to evaluate different risk factors for anal fissure development (Tab. 2, Ref. 11). Full Text (Free, PDF) www.bmj.sk.

  17. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and...

  18. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...

  19. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...

  20. Phreatic explosions during basaltic fissure eruptions: Kings Bowl lava field, Snake River Plain, USA

    NASA Astrophysics Data System (ADS)

    Hughes, Scott S.; Kobs Nawotniak, Shannon E.; Sears, Derek W. G.; Borg, Christian; Garry, William Brent; Christiansen, Eric H.; Haberle, Christopher W.; Lim, Darlene S. S.; Heldmann, Jennifer L.

    2018-02-01

    Physical and compositional measurements are made at the 7 km-long ( 2200 years B.P.) Kings Bowl basaltic fissure system and surrounding lava field in order to further understand the interaction of fissure-fed lavas with phreatic explosive events. These assessments are intended to elucidate the cause and potential for hazards associated with phreatic phases that occur during basaltic fissure eruptions. In the present paper we focus on a general understanding of the geological history of the site. We utilize geospatial analysis of lava surfaces, lithologic and geochemical signatures of lava flows and explosively ejected blocks, and surveys via ground observation and remote sensing. Lithologic and geochemical signatures readily distinguish between Kings Bowl and underlying pre-Kings Bowl lava flows, both of which comprise phreatic ejecta from the Kings Bowl fissure. These basalt types, as well as neighboring lava flows from the contemporaneous Wapi lava field and the older Inferno Chasm vent and outflow channel, fall compositionally within the framework of eastern Snake River Plain olivine tholeiites. Total volume of lava in the Kings Bowl field is estimated to be 0.0125 km3, compared to a previous estimate of 0.005 km3. The main (central) lava lake lost a total of 0.0018 km3 of magma by either drain-back into the fissure system or breakout flows from breached levees. Phreatic explosions along the Kings Bowl fissure system occurred after magma supply was cut off, leading to fissure evacuation, and were triggered by magma withdrawal. The fissure system produced multiple phreatic explosions and the main pit is accompanied by others that occur as subordinate pits and linear blast corridors along the fissure. The drop in magma supply and the concomitant influx of groundwater were necessary processes that led to the formation of Kings Bowl and other pits along the fissure. A conceptual model is presented that has relevance to the broader range of low-volume, monogenetic

  1. Multispectral near-infrared reflectance and transillumination imaging of occlusal carious lesions: variations in lesion contrast with lesion depth

    NASA Astrophysics Data System (ADS)

    Simon, Jacob C.; Curtis, Donald A.; Darling, Cynthia L.; Fried, Daniel

    2018-02-01

    In vivo and in vitro studies have demonstrated that near-infrared (NIR) light at λ=1300-1700-nm can be used to acquire high contrast images of enamel demineralization without interference of stains. The objective of this study was to determine if a relationship exists between the NIR image contrast of occlusal lesions and the depth of the lesion. Extracted teeth with varying amounts of natural occlusal decay were measured using a multispectral-multimodal NIR imaging system which captures λ=1300-nm occlusal transillumination, and λ=1500-1700-nm cross-polarized reflectance images. Image analysis software was used to calculate the lesion contrast detected in both images from matched positions of each imaging modality. Samples were serially sectioned across the lesion with a precision saw, and polarized light microscopy was used to measure the respective lesion depth relative to the dentinoenamel junction. Lesion contrast measured from NIR crosspolarized reflectance images positively correlated (p<0.05) with increasing lesion depth and a statistically significant difference between inner enamel and dentin lesions was observed. The lateral width of pit and fissures lesions measured in both NIR cross-polarized reflectance and NIR transillumination positively correlated with lesion depth.

  2. Hemorrhoids and anal fissures in inflammatory bowel disease.

    PubMed

    D'Ugo, S; Stasi, E; Gaspari, A L; Sileri, P

    2015-12-01

    Perianal disease is a common complication of inflammatory bowel disease (IBD). It includes different conditions from more severe and potentially disabling ones, such as abscesses and fistulas, to more benign conditions such as hemorrhoids, skin tags and fissures. Most literature has been focused on anal sepsis and fistulae, as they carry the majority of disease burden and often alter the natural course of the disease. Hemorrhoids and anal fissures in patients with IBD have been overlooked, although they can represent a challenging problem. The management of hemorrhoids and fissures in IBD patients may be difficult and may significantly differ compared to the non-affected population. Historically surgery was firmly obstructed, and hemorrhoidectomy or sphincterotomy in patients with associated diagnosis of IBD was considered harmful, although literature data is scant and based on small series. Various authors reported an incidence of postoperative complications higher in IBD than in the general populations, with potential severe events. Considering that a spontaneous healing is possible, the first line management should be a medical therapy. In patients non-responding to conservative measures it is possible a judicious choice of surgical options on a highly selective basis; this can lead to acceptable results, but the risk of possible complications needs to be considered. In this review it is analyzed the current literature on the incidence, symptoms and treatment options of hemorrhoids and anal fissures in patients with Crohn's disease and ulcerative colitis.

  3. Geometry of the September 1971 eruptive fissure at Kilauea volcano, Hawaii

    USGS Publications Warehouse

    Dvorak, J.J.

    1990-01-01

    A three-dimensional model has been used to estimate the location and dimensions of the eruptive fissure for the 24-29 September 1971 eruption along the southwest rift zone of Kilauea volcano, Hawaii. The model is an inclined rectangular sheet embedded in an elastic half-space with constant displacement on the plane of the sheet. The set of "best" model parameters suggests that the sheet is vertical, extends from a depth of about 2 km to the surface, and has a length of about 14 km. Because this sheet intersects the surface where eruptive vents and extensive ground cracking formed during the eruption, this sheet probably represents the conduit for erupted lava. The amount of displacement perpendicular to the sheet is about 1.9 m, in the middle range of values measured for the amount of opening across the September 1971 eruptive fissure. The thickness of the eruptive fissure associated with the January 1983 east rift zone eruption was determined in an earlier paper to be 3.6 m, about twice the thickness determined here for the September 1971 eruption. Because the lengths (12 km for 1983 and 14 km for 1971) and heights (about 2 km) of the sheet models derived for the January 1983 and September 1971 rift zone eruptions are nearly identical, the greater thickness for the January 1983 eruptive fissure implies that the magma pressure was about a factor of two greater to form the January 1983 eruptive fissure. Because the September 1971 and January 1983 eruptive fissures extent to depths of only a few kilometers, the region of greatest compressive stress produced along the volcano's flank by either of these eruptive fissures would also be within a few kilometers of the surface. Previous work has shown that rift eruptions and intrusions contribute to the buildup of compressive stress along Kilauea's south flank and that this buildup is released by increased seismicity along the south flank. Because south flank earthquakes occur at significantly greater depths, i.e., from 5

  4. Adherence evaluation of vented chest seals in a swine skin model.

    PubMed

    Arnaud, Françoise; Maudlin-Jeronimo, Eric; Higgins, Adam; Kheirabadi, Bijan; McCarron, Richard; Kennedy, Daniel; Housler, Greggory

    2016-10-01

    Perforation of the chest (open pneumothorax) with and without lung injury can cause air accumulation in the chest, positive intrapleural pressure and lead to tension pneumothorax if untreated. The performance of chest seals to prevent tension physiology depends partially on their ability to adhere to the skin and seal the chest wound. Novel non-occlusive vented chest seals were assessed for their adhesiveness on skin of live swine under normal and extreme environmental conditions to simulate austere battlefield conditions. Chest seals were applied on the back of the swine on skin that was soiled by various environmental contaminants to represent battlefield situations. A peeling (horizontal rim peeling) and detachment and breaching (vertical pulling) techniques were used to quantify the adhesive performance of vented chest seals. Among eight initially selected vented seals, five (Bolin, Russell, Fast breathe, Hyfin and SAM) were further down-selected based on their superior adherence scores at ambient temperatures. The adherence of these seals was then assessed after approximately 17h storage at extreme cold (-19.5°C) and hot (71.5°C) temperatures. Adherence scores for peeling (above 90%) and detachment scores (less than 25%) were comparable for four vented chest seals when tested at ambient temperature, except for the Bolin seal which had higher breaching. Under extreme storage temperatures, adherence peeling scores were comparable to those at ambient temperatures for four chest seals. Scores were significantly lower for the Bolin seal at extreme temperatures. This seal also had the highest detachment and breaching scores. In contrast, the Russell, Fast breathe, Hyfin and SAM seals showed similar ability to stay air tight without breaching after hot storage. No significant difference was found in skin adherence of the five vented chest seals at ambient temperature and the four seals (Russell, Fast breathe, Hyfin and SAM) maintained superior adherence even after

  5. Preserving rice quality: fine mapping and introgressing a fissure resistance locus

    USDA-ARS?s Scientific Manuscript database

    Rice (Oryza sativa L.) kernel fissuring is a major concern of both rice producers and millers. Fissures are small cracks in the rice kernels that increase the percentage of breakage among the kernels when they are transported and milled, which decreases the value of processed rice. This study employ...

  6. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    PubMed

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (< 60 years old) and elderly (60 years old or more) patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  7. Glass ionomer ART sealant and fluoride-releasing resin sealant in fissure caries prevention – results from a randomized clinical trial

    PubMed Central

    2014-01-01

    Background The relative performance of ART sealant and fluoride-releasing resin sealant in preventing fissure caries in permanent molars was compared in a randomized clinical trial conducted in southern China (ClinicalTrials.gov NCT01829334). Methods After obtaining ethical approval, healthy schoolchildren who had permanent first molars with occlusal fissures which were sound but deep or presented with only incipient caries were recruited for the study. Included molars were randomly allocated into one of four parallel study groups in units of left/right teeth per mouth. Two of the four groups adopted the methods of ART or fluoride-releasing resin sealant placement while the other two groups adopted the topical fluoride application methods. Fissure status of the molars in each group was evaluated every 6 months. Development of dentine caries and sealant retention over 24 months in the molars in the two sealant-using groups was compared in this report. Outcome on cost-effectiveness of all four groups over 36 months will be reported elsewhere. Results At baseline, a total of 280 children (383 molars) with mean age 7.8 years were involved for the two sealant groups. After 24 months, 261 children (357 molars) were followed. Proportions of molars with dentine caries were 7.3% and 3.9% in the ART sealant and fluoride-releasing resin sealant groups, respectively (chi-square test, p = 0.171). Life-table survival analysis showed that sealant retention (full and partial) rate over 24 months for the resin sealant (73%) was significantly higher than that (50%) for the ART sealant (p < 0.001). Molar survival (no development of dentine caries) rates in the ART sealant (93%) and fluoride-releasing resin sealant (96%) groups were not significantly different (p = 0.169). Multilevel logistic regression (GEE modeling) accounting for the effects of data clustering and confounding factors confirmed this finding. Conclusions Though the retention of fluoride

  8. Differential compaction mechanism for earth fissures near Casa Grande, Arizona.

    USGS Publications Warehouse

    Jachens, R.C.; Holzer, T.L.

    1982-01-01

    Precise gravity measurements indicate that earth fissures or tension cracks caused by ground-water withdrawal within a 10km2 area SE of Casa Grande are associated with relief on the buried interface between the alluvial aquifer and underlying bedrock. These relations suggest that the fissures are forming in response to localized differential compaction caused by localized variations of aquifer-system thickness. -from Authors

  9. Internal sphincterotomy versus topical nitroglycerin ointment for chronic anal fissure.

    PubMed

    Aslam, Muhammad I; Pervaiz, Arif; Figueiredo, Rodrigo

    2014-01-01

    Anal fissure is a common benign condition. An anorectal problem is defined as a split in the anal canal mucosa that extends from the dentate line to the anal verge. Chronic anal fissure is defined by a history of symptoms present for more than 2 months' duration and with a triad of external skin tags, namely, a hypertrophied anal papilla, an ulcer with rolled edges, and a base exposing the internal sphincter. Because complications such as incontinence are associated with surgical treatment, chemical sphincterotomy is currently favored. The objective of this study is to compare the difference in outcome between open partial lateral anal sphincterotomy and application of topical 0.2% nitroglycerin ointment for the treatment of chronic anal fissure. This was a quasi-experimental study carried out between January 16, 2007 and January 15, 2008 in the Surgical Department of Jinnah Hospital, Lahore, Pakistan. Sixty consecutive cases with a clinical diagnosis of chronic anal fissure were recruited in the study. All recruited patients met the study inclusion criteria and were randomly assigned to one of the two groups. Group A was managed conservatively using topical 0.2% nitroglycerin ointment, whereas Group B underwent open partial lateral anal sphincterotomy. Both groups were followed up at 1 week, 2 weeks, 4 weeks, and 6 weeks after the treatment. All the patients complained of pain. A total of 43 (71.7%) patients had pain with constipation, whereas 31 (51.7%) patients had bleeding per rectum. Upon clinically examining the anal area, tenderness was elicited in all 60 (100%) patients. Group A included 30 (11 females and 19 males) cases treated with topical 0.2% nitroglycerin ointment and Group B included 30 (11 females and 19 males) cases who underwent open partial lateral anal sphincterotomy. In Group A, only 15 patients with fissures were successfully treated (50%). By contrast, 28 (93%) patients with fissures in Group B were successfully treated, and only two (7

  10. [Application of individually designed trans-fissure approach in brain surgery: analysis of 90 cases].

    PubMed

    Zhao, Ji-Zong; Wang, Shuo; Zhang, Mao-Zhi; Wang, Lei; Wang, Rong; Tang, Ya-Juan

    2009-01-06

    To explore the feasibility and value of trans-fissure approaches in brain surgery through individually designed craniotomy. Ninety patients with intracranial space-occupying lesions, 47 males and 58 females, aged (43 +/- 14) (1 - 68), were treated by individualized trans-fissure approach surgeries. Linear scalp incision or "horseshoe shape" scalp incision were designed to perform the operation, with a bone flap 3 - 4 cm in diameter. The shortest approach to reach the lesion was decided under the guidance of neuro-navigation and real-time B-mode ultrasonography. Then the lesions were removed through natural cortical fissures. Another 79 patients with intracranial space-occupying lesions, 53 males and 51 females, aged (42 +/- 11) (15 -73), undergoing classical surgeries in the same period were used as control group. The average operation time, size of bone flap, amount of blood loss, hospitalization time, and hospitalization cost were compared between these 2 groups. The operation time of the individually designed trans-fissure approach group was (3.1 +/- 1.6) hours (1.33 - 10.83 hours), significantly shorter than that of the control group [(4.8 +/- 1.9) hrs, P < 0.05]. The amount of blood loss of the individually designed trans-fissure approach group was (173 +/- 168) ml (20 m - 500 ml), significantly less than that of the control group [(410 +/- 61) ml, P < 0.01]. The size of bone flap of the individually designed trans-fissure approach group was (12 +/- 5) cm2 [(1 - 25) cm2], significantly smaller than that of the control group [(20. +/- 9) cm2, P < 0.01]. Four of the 90 patients of the individually designed trans-fissure approach group received retransfusion, compared to 15 in the control group, during operation. No infection or other significant complications occurred after operation in the individually designed trans-fissure approach group. The hospitalization time of the individually designed trans-fissure approach group was (20 +/- 6) days (9 - 39 days

  11. Efficacy of nitroglycerine ointment in the treatment of pediatric anal fissure.

    PubMed

    Joda, Ali E; Al-Mayoof, Ali F

    2017-11-01

    Anal fissure is the most common anal disease in children. In the past few decades, the understanding of its pathophysiology has led to a progressive reduction in invasive procedures in favor of conservative treatment based on stool softeners and the relaxation of the anal sphincter. This randomized controlled study assessed the safety and efficacy of nitroglycerine (NTG) ointment in the treatment of pediatric anal fissure, which had not yet been proved. An unequal randomized controlled study included 105 pediatric patients with anal fissure who had presented to the private and outpatient clinics of the Central Teaching Hospital of Pediatrics during the period from February 2015 to May 2016. The control group consisted of 70 patients. Both groups were treated with classical conservative therapy of sitz bath, stool softener, and local anesthetic. In the second group, chemical sphincterotomy with 0.2% NTG ointment was used in 35 patients, and was applied at the anal canal twice daily for 8weeks. The primary outcomes of symptomatic improvement and healed fissure, as well as side effects, were analyzed. The average age of patients was 2years (range, 4months to 5years). Patients in the NTG group had 77% symptomatic relief and 60% healed fissure compared to the control group, which had 54% and 32.8% respectively. All were statistically significant. No serious adverse effects were noticed during the treatment period. The use of 0.2% NTG ointment is an effective therapy for anal fissure in children in terms of good healing rate and rapid symptom relief, but it has the drawback of a long treatment period, making patient compliance more difficult, in addition to the problems of tolerance and recurrence. Prospective randomized controlled study (treatment study). Type 2. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Seals and Sealing Techniques

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Developments by the aerospace industry in seals and sealing techniques are announced for possible use in other areas. The announcements presented are grouped as: sealing techniques for cryogenic fluids, high pressure applications, and modification for improved performance.

  13. Numerical simulation of earth fissures caused by overly aquifer exploitation at Guangming Village, China

    NASA Astrophysics Data System (ADS)

    Ye, S.; Franceschini, A.; Zhang, Y.; Janna, C.; Gong, X.; Yu, J.; Teatini, P.

    2017-12-01

    Earth fissures accompanying anthropogenic land subsidence due to overly aquifer exploitation create significant geohazards in China. In the framework of an efficient and safe management of groundwater, numerical models represent a unique scientific approach to predict the generation and development of earth fissures. However, the common geomechanical simulators fail to reproduce fissure development because, due to compatibility conditions, they cannot be effectively applied in discontinuous mechanics. We present an innovative modelling approach for the simulation of fissure development. Firstly, a regional 3D groundwater model is calibrated on available piezometric records; secondly, the regional outcome is used to define the boundary conditions of a local 3D groundwater model developed at the fissure scale and implementing a refined discretization of the local hydrogeologic setting; finally, the pressure change are used as forcing factor in a local 3D geomechanical model, which combines Finite Elements and Interface Elements to simulate the deformation of the continuous aquifer system and the generation and sliding/opening of earth fissures The approach has been applied to simulate the earth fissure at Guangming Village in Wuxi, China with land subsidence of more than 1 m caused by the overexploitation of the second confined aquifer. The first earth fissure was observed in 1998. It developed fast from 1998 to 2007. The domain addressed by the local simulations is 2 km wide and 5 km long. The thickness of the aquifer system ranges from 0 m, in the proximity of a mountain ridge southward, to 210 m northward and includes a phreatic aquifer, the first and second confined aquifers, and four aquitards. The simulations spanned the period from 1980, i.e. before the inception of large groundwater withdrawals, to 2015. The modelling results highlight that the earth fissures at Guangming Village have been caused by tension and shear, which developed from the land surface

  14. Haemorrhoids and anal fissures during pregnancy and after childbirth: a prospective cohort study.

    PubMed

    Poskus, T; Buzinskienė, D; Drasutiene, G; Samalavicius, N E; Barkus, A; Barisauskiene, A; Tutkuviene, J; Sakalauskaite, I; Drasutis, J; Jasulaitis, A; Jakaitiene, A

    2014-12-01

    To identify the incidence and risk factors of haemorrhoids and fissures during pregnancy and after childbirth. Prospective observational cohort study. University hospital and outpatient clinics in Lithuania. A total of 280 pregnant women followed up until 1 month after delivery. Women were examined four times through pregnancy and after delivery; those that developed peri-anal diseases were compared with those that did not. Incidence, time and risk factors of haemorrhoids and fissures. In all, 123 (43.9%) women developed peri-anal disease: 1.6% in the first trimester, 61% during the third trimester, 34.1% after delivery and 3.3% 1 month after delivery; 114 (40.7%) women were diagnosed with haemorrhoids, seven (2.5%) with haemorrhoids and anal fissure and two (0.71%) with anal fissure. Ninety-nine (80.5%) women had vaginal delivery and 24 (19.5%) women had undergone caesarean section. Multivariate analysis identified personal history of peri-anal diseases (odds ratio [OR] 11.93; 95% confidence interval [95% CI] 2.18-65.30), constipation (OR 18.98; 95% CI 7.13-50.54), straining during delivery for more than 20 minutes (OR 29.75; 95% CI 4.00-221.23) and birthweight of newborn>3800 g (OR 17.99; 95% CI 3.29-98.49) as significant predictors of haemorrhoids and anal fissures during pregnancy and perinatal period. Haemorrhoids and fissures are common during the last trimester of pregnancy and 1 month after delivery, with constipation, personal history of haemorrhoids or fissures, birthweight of newborn>3800 g, straining during delivery for more than 20 minutes being independently associated risk factors. © 2014 Royal College of Obstetricians and Gynaecologists.

  15. The Performance of ICDAS-II Using Low-Powered Magnification with Light-Emitting Diode Headlight and Alternating Current Impedance Spectroscopy Device for Detection of Occlusal Caries on Primary Molars.

    PubMed

    Ari, Timucin; Ari, Nilgun

    2013-01-01

    Early detection of occlusal caries in children is challenging for the dentists, because of the morphology of pit and fissures. The aim of this study was to compare in vitro the diagnostic performance of low-powered magnification with light-emitting diode headlight (LPMLED) using ICDAS-II criteria and AC Impedance Spectroscopy (ACIS) device, on occlusal surfaces of primary molars. The occlusal surfaces of 18 extracted primary molars were examined blindly by two examiners. The teeth were sectioned and examined under light microscopy using Downer's histological criteria as gold standard. Good to excellent inter- and intraexaminer reproducibility, higher sensitivity, specificity, and AUC values were achieved by LPMLED at D1 threshold. Also the relationship between histology and LPMLED was statistically significant. In conclusion visual aids have the potential to improve the performance of early caries detection and clinical diagnostics in children. Despite its potential, ACIS device should be considered as an adjunct method in detecting caries on primary teeth.

  16. Maps showing water-level declines, land subsidence, and earth fissures in south-central Arizona

    USGS Publications Warehouse

    Laney, R.L.; Raymond, R.H.; Winikka, C.C.

    1978-01-01

    From 1915 to 1975, more than 109 million acre-feet of ground water was withdrawn from about 4,500 square miles in Pinal and Maricopa Counties in south-central Arizona. The volume of water withdrawn greatly exceeds the volume of natural recharge, and water levels have been declining since 1923. As a result of the water-level declines, the land surface has subsided, the alluvial deposits have been subjected to stress, and earth fissures have developed. Land subsidence and earth fissures have damaged public and private properties. Subsidence and fissures will continue to occur as long as ground water is being mined and water levels continue to decline. As urban development expands, land subsidence and earth fissures will have an increasing socioeconomic impact. Information on maps includes change in water levels, measurements of land subsidence, and location of earth fissures. A section showing land subsidence between Casa Grande and the Picacho Peak Interchange also is included. Scale 1:250,000. (Woodard-USGS)

  17. Adaptive Management of Land Subsidence and Ground Fissuring in the Chino Groundwater Basin, California

    NASA Astrophysics Data System (ADS)

    Malone, A.; Rolfe, T.; Wildermuth, M.; Kavounas, P.

    2014-12-01

    The Chino Basin, located in southern California, is a large alluvial groundwater basin with storage in excess of five million acre-feet. The basin has a long history of groundwater development for various uses dating back to the early 1900s. As a result, piezometric heads declined basin-wide during the past century - in some areas by more than 200 feet. Declines of this magnitude typically cause irreversible aquifer-system compaction, which in turn results in subsidence at the ground surface. In portions of Chino Basin, land subsidence has been differential and accompanied by ground fissuring, which damaged existing infrastructure and poses concerns for new and existing development.Chino Basin Watermaster, the agency responsible for groundwater basin management, has recognized that land subsidence and ground fissuring should be minimized to the extent possible. At the same time, Watermaster is implementing aggressive groundwater-supply programs that include controlled overdraft and the possibility of causing head declines in areas prone to subsidence and fissuring. The groundwater-supply programs must also address the subsidence and fissuring phenomena.From 2001 to 2005, Watermaster conducted a technical investigation to characterize the extent, rate, and mechanisms of subsidence and fissuring. The investigation employed InSAR and ground-level surveying of benchmarks to monitor ground-surface deformation, and borehole extensometers and piezometric monitoring to establish the relationships between groundwater production, piezometric levels, and aquifer-system deformation. Based on the results of the investigation, Watermaster developed: (i) subsidence-management criteria for the areas experiencing acute subsidence and fissuring, and (ii) an adaptive management program to minimize the potential for future subsidence and fissuring across the entire Chino Basin. The science-based program includes ongoing monitoring, which now includes sophisticated fissure

  18. Expression profiling during ocular development identifies 2 Nlz genes with a critical role in optic fissure closure.

    PubMed

    Brown, Jacob D; Dutta, Sunit; Bharti, Kapil; Bonner, Robert F; Munson, Peter J; Dawid, Igor B; Akhtar, Amana L; Onojafe, Ighovie F; Alur, Ramakrishna P; Gross, Jeffrey M; Hejtmancik, J Fielding; Jiao, Xiaodong; Chan, Wai-Yee; Brooks, Brian P

    2009-02-03

    The gene networks underlying closure of the optic fissure during vertebrate eye development are poorly understood. Here, we profile global gene expression during optic fissure closure using laser capture microdissected (LCM) tissue from the margins of the fissure. From these data, we identify a unique role for the C(2)H(2) zinc finger proteins Nlz1 and Nlz2 in normal fissure closure. Gene knockdown of nlz1 and/or nlz2 in zebrafish leads to a failure of the optic fissure to close, a phenotype which closely resembles that seen in human uveal coloboma. We also identify misregulation of pax2 in the developing eye of morphant fish, suggesting that Nlz1 and Nlz2 act upstream of the Pax2 pathway in directing proper closure of the optic fissure.

  19. Modeling plaque fissuring and dissection during balloon angioplasty intervention.

    PubMed

    Gasser, T Christian; Holzapfel, Gerhard A

    2007-05-01

    Balloon angioplasty intervention is traumatic to arterial tissue. Fracture mechanisms such as plaque fissuring and/or dissection occur and constitute major contributions to the lumen enlargement. However, these types of mechanically-based traumatization of arterial tissue are also contributing factors to both acute procedural complications and chronic restenosis of the treatment site. We propose physical and finite element models, which are generally useable to trace fissuring and/or dissection in atherosclerotic plaques during balloon angioplasty interventions. The arterial wall is described as an anisotropic, heterogeneous, highly deformable, nearly incompressible body, whereas tissue failure is captured by a strong discontinuity kinematics and a novel cohesive zone model. The numerical implementation is based on the partition of unity finite element method and the interface element method. The later is used to link together meshes of the different tissue components. The balloon angioplasty-based failure mechanisms are numerically studied in 3D by means of an atherosclerotic-prone human external iliac artery, with a type V lesion. Image-based 3D geometry is generated and tissue-specific material properties are considered. Numerical results show that in a primary phase the plaque fissures at both shoulders of the fibrous cap and stops at the lamina elastica interna. In a secondary phase, local dissections between the intima and the media develop at the fibrous cap location with the smallest thickness. The predicted results indicate that plaque fissuring and dissection cause localized mechanical trauma, but prevent the main portion of the stenosis from high stress, and hence from continuous tissue damage.

  20. Glaser Fissure, Huguier Canal, and Civinini Canal: A Confused Eponymical Imbroglio.

    PubMed

    Mudry, Albert

    2015-07-01

    Huguier canal or Civinini canal is a canaliculus in the Glaser fissure allowing the exit of the chorda tympani from the tympanic cavity. The aim of this study is to try to put some order in the origins and relations of these different eponyms, and to evaluate their pertinence in the actual anatomical terminology. This study demonstrates that Huguier and Civinini are not the first to describe this canal in the 1830s. Furthermore, it confirms that Glaser does not describe the related fissure in 1680. In conclusion, Glaser, Civinini, and Huguier no longer have a place in the actual anatomical nomenclature of the fine details of the temporal bone. To avoid confusion and errors, they must be replaced by anterior canaliculus for the chorda tympani and petrotympanic fissure.

  1. Does the duration of symptoms of anal fissure impact its response to conservative treatment? A prospective cohort study.

    PubMed

    Emile, Sameh Hany; Elgendy, Hesham; Elfeki, Hossam; Magdy, Alaa; Abdelmawla, Ahmed Aly; Abdelnaby, Mahmoud; Khafagy, Wael

    2017-08-01

    Conservative treatment is the first line of treatment for anal fissure. The current study aimed to evaluate the impact of symptom duration on the response of anal fissure to conservative treatment. This prospective study was conducted on sixty patients with acute or chronic anal fissure who were treated conservatively with bulking agents, Sitz baths, and topical glyceryl trinitrate (GTN) 0.2%. Pain and constipation were assessed prior to treatment and at 6 weeks after therapy using visual analogue scale (VAS) and Wexner constipation score. Adverse effects as headache and postural hypotension were also queried. The mean pre-treatment VAS for acute fissure was significantly higher than chronic fissure (8.8 ± 0.96 Vs 5.8 ± 1.12), also the post-treatment VAS for acute fissure was significantly lower at 6 weeks of treatment (0.47 ± 0.8 Vs 2.5 ± 1.3). The baseline Wexner constipation score was comparable in both groups; however, at six weeks of treatment it declined more significantly in patients with acute fissure. Patients with acute fissure achieved significantly better healing than chronic fissure (80% Vs 40%). Healing rates decreased from 100% in patients with symptoms < one month to 33.3% in patients with symptoms >6 months. Conservative treatment including topical GTN 0.2% significantly hastened healing and relieved pain and other symptoms of acute more than chronic anal fissure. Healing rates of anal fissure in response to conservative treatment showed remarkable decrease in proportion to the duration of complaint. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  2. Retention of fissure sealants in young permanent molars affected by dental fluorosis: a 12-month clinical study.

    PubMed

    Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A

    2014-10-01

    To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.

  3. Treatment for anal fissure: Is there a safe option?

    PubMed

    Brady, Justin T; Althans, Alison R; Neupane, Ruel; Dosokey, Eslam M G; Jabir, Murad A; Reynolds, Harry L; Steele, Scott R; Stein, Sharon L

    2017-10-01

    Surgeons often approach anal fissure with chemical denervation (Botulinum toxin, BT) instead of initial lateral internal sphincterotomy (LIS) due to concerns for long-term incontinence. We evaluated the characteristics and outcomes of patients who received BT or LIS. We performed a retrospective chart review of patients undergoing LIS and BT for anal fissure between 2009 and 2015. In 2015, a telephone survey was performed to evaluate durability, long-term incontinence and patient satisfaction. Ninety-four patients met criteria: 73 LIS and 21 BT. Age (BT 49 vs. LIS 52) was similar between groups (p = 1.0). Cleveland Clinic Fecal Incontinence (CCFI) score pre-intervention was higher in BT than LIS patients (2.1 vs. 0.4, p = 0.007) with fewer BT patients with perfect continence (50% vs. 88%). Telephone survey response was 61%. Fissure recurrence was significantly higher for BT than LIS patients (36% vs. 9%, p = 0.03). Patients undergoing LIS were less likely to recur. Both LIS and BT patients had some durable changes in continence raising the question of whether there is a safe technique. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Contracting/expanding self-sealing cryogenic tube seals

    NASA Technical Reports Server (NTRS)

    Jia, Lin X. (Inventor)

    1997-01-01

    Contracting/expanding self-sealing cryogenic tube seals are disclosed which use the different properties of thermal contraction and expansion of selected dissimilar materials in accord with certain design criteria to yield self-tightening seals via sloped-surface sealing. The seals of the subject invention are reusable, simple to assemble, adaptable to a wide variety of cryogenic applications.

  5. Contracting/expanding self-sealing cryogenic tube seals

    NASA Technical Reports Server (NTRS)

    Jia, Lin X. (Inventor)

    1997-01-01

    Contracting/expanding self-sealing cryogenic tube seals are disclosed which use the different properties of thermal contraction and expansion of selected dissimilar materials in accord with certain design criteria to yield self-tightening seals via sloped-surface sealing. The seals of the subject invention are reusable, simple to assemble, and adaptable to a wide variety of cryogenic applications.

  6. An experimental study on fracture mechanical behavior of rock-like materials containing two unparallel fissures under uniaxial compression

    NASA Astrophysics Data System (ADS)

    Huang, Yan-Hua; Yang, Sheng-Qi; Tian, Wen-Ling; Zeng, Wei; Yu, Li-Yuan

    2016-06-01

    Strength and deformability characteristics of rock with pre-existing fissures are governed by cracking behavior. To further research the effects of pre-existing fissures on the mechanical properties and crack coalescence process, a series of uniaxial compression tests were carried out for rock-like material with two unparallel fissures. In the present study, cement, quartz sand, and water were used to fabricate a kind of brittle rock-like material cylindrical model specimen. The mechanical properties of rock-like material specimen used in this research were all in good agreement with the brittle rock materials. Two unparallel fissures (a horizontal fissure and an inclined fissure) were created by inserting steel during molding the model specimen. Then all the pre-fissured rock-like specimens were tested under uniaxial compression by a rock mechanics servo-controlled testing system. The peak strength and Young's modulus of pre-fissured specimen all first decreased and then increased when the fissure angle increased from 0° to 75°. In order to investigate the crack initiation, propagation and coalescence process, photographic monitoring was adopted to capture images during the entire deformation process. Moreover, acoustic emission (AE) monitoring technique was also used to obtain the AE evolution characteristic of pre-fissured specimen. The relationship between axial stress, AE events, and the crack coalescence process was set up: when a new crack was initiated or a crack coalescence occurred, the corresponding axial stress dropped in the axial stress-time curve and a big AE event could be observed simultaneously. Finally, the mechanism of crack propagation under microscopic observation was discussed. These experimental results are expected to increase the understanding of the strength failure behavior and the cracking mechanism of rock containing unparallel fissures.

  7. Traumatic superior orbital fissure syndrome: assessment of cranial nerve recovery in 33 cases.

    PubMed

    Chen, Chien-Tzung; Wang, Theresa Y; Tsay, Pei-Kwei; Huang, Faye; Lai, Jui-Pin; Chen, Yu-Ray

    2010-07-01

    Superior orbital fissure syndrome is a rare complication that occurs in association with craniofacial trauma. The characteristics of superior orbital fissure syndrome are attributable to a constellation of cranial nerve III, IV, and VI palsies. This is the largest series describing traumatic superior orbital fissure syndrome that assesses the recovery of individual cranial nerve function after treatment. In a review from 1988 to 2002, 33 patients with superior orbital fissure syndrome were identified from 11,284 patients (0.3 percent) with skull and facial fractures. Severity of cranial nerve injury and functional recovery were evaluated by extraocular muscle movement. Patients were evaluated on average 6 days after initial injury, and average follow-up was 11.8 months. There were 23 male patients. The average age was 31 years. The major mechanism of injury was motorcycle accident (67 percent). Twenty-two received conservative treatment, five were treated with steroids, and six patients underwent surgical decompression of the superior orbital fissure. After initial injury, cranial nerve VI suffered the most damage, whereas cranial nerve IV sustained the least. In the first 3 months, recovery was greatest in cranial nerve VI. At 9 months, function was lowest in cranial nerve VI and highest in cranial nerve IV. Eight patients (24 percent) had complete recovery of all cranial nerves. Functional recovery of all cranial nerves reached a plateau at 6 months after trauma. Cranial nerve IV suffered the least injury, whereas cranial nerve VI experienced the most neurologic deficits. Cranial nerve palsies improved to their final recovery endpoints by 6 months. Surgical decompression is considered when there is evidence of bony compression of the superior orbital fissure.

  8. Calcified gallstone fissures: the reversed Mercedes Benz sign.

    PubMed

    Strijk, S P

    1987-01-01

    This article describes the occurrence of an unusual radiating pattern of calcification in the center of large radiolucent gallstones. The radiographic findings are attributed to calcium deposition within the fissures of biliary calculi.

  9. Thermomechanical behavior of mica layers with lenticular fissures

    NASA Astrophysics Data System (ADS)

    Yang, Michael Xinyi

    The thermomechanical behavior of natural phlogopite mica specimens from seven different origins is characterized. An initial heat treatment, to a temperature between 300°C and 400°C, is found to form fissures that stabilize in the material. Following the initial heat treatment, all the phlogopite specimens, regardless of their origin and polytype, exhibit the extraordinarily large thermal expansion (intumescence), more than 200% at 600°C, in the direction perpendicular to the basal planes. This phenomenon is strictly reproducible when tested under a range of thermal conditions including thermal shock, multiple thermal fatigue cycles, varying heating or cooling rates and isothermal heating over an extensive period of time at different temperatures up to 585°C. The hysteresis, associated with the thermal cycle, is increased when the specimen is heated or cooled at a faster rate. The maximum coefficient of linear thermal expansion, approximately 10 -2°C-1, is observed over the temperature range 100--120°C. This is due to the non-structural water, entrapped within the layer structure, which undergoes a phase transition and causes the mica layers to expand abruptly. A model of lenticular fissures is developed based on thin-plate mechanics and thermodynamics assumptions. The state of a lenticular fissure with water vapor molecules is determined to correlate the experimental parameters with the material properties. The average density of water vapor molecules within a lenticular fissure is calculated to be ˜1025 m 3 for the temperature interval between 100°C and 275°C. The concentration of non-structure water, based on the model calculation, is less than 0.1% by weight. Acoustic emission (AE) signals have been reported by Pranevicius et al. (1995) to correspond to the microstructure changes as the internal lenticular fissures develop in phlogopite. This technique has also been proven feasible to characterize the thermomechanical behavior of other layer structures

  10. A study on using texture analysis methods for identifying lobar fissure regions in isotropic CT images.

    PubMed

    Wei, Q; Hu, Y

    2009-01-01

    The major hurdle for segmenting lung lobes in computed tomographic (CT) images is to identify fissure regions, which encase lobar fissures. Accurate identification of these regions is difficult due to the variable shape and appearance of the fissures, along with the low contrast and high noise associated with CT images. This paper studies the effectiveness of two texture analysis methods - the gray level co-occurrence matrix (GLCM) and the gray level run length matrix (GLRLM) - in identifying fissure regions from isotropic CT image stacks. To classify GLCM and GLRLM texture features, we applied a feed-forward back-propagation neural network and achieved the best classification accuracy utilizing 16 quantized levels for computing the GLCM and GLRLM texture features and 64 neurons in the input/hidden layers of the neural network. Tested on isotropic CT image stacks of 24 patients with the pathologic lungs, we obtained accuracies of 86% and 87% for identifying fissure regions using the GLCM and GLRLM methods, respectively. These accuracies compare favorably with surgeons/radiologists' accuracy of 80% for identifying fissure regions in clinical settings. This shows promising potential for segmenting lung lobes using the GLCM and GLRLM methods.

  11. The effect of CT technical factors on quantification of lung fissure integrity

    NASA Astrophysics Data System (ADS)

    Chong, D.; Brown, M. S.; Ochs, R.; Abtin, F.; Brown, M.; Ordookhani, A.; Shaw, G.; Kim, H. J.; Gjertson, D.; Goldin, J. G.

    2009-02-01

    A new emphysema treatment uses endobronchial valves to perform lobar volume reduction. The degree of fissure completeness may predict treatment efficacy. This study investigated the behavior of a semiautomated algorithm for quantifying lung fissure integrity in CT with respect to reconstruction kernel and dose. Raw CT data was obtained for six asymptomatic patients from a high-risk population for lung cancer. The patients were scanned on either a Siemens Sensation 16 or 64, using a low-dose protocol of 120 kVp, 25 mAs. Images were reconstructed using kernels ranging from smooth to sharp (B10f, B30f, B50f, B70f). Research software was used to simulate an even lower-dose acquisition of 15 mAs, and images were generated at the same kernels resulting in 8 series per patient. The left major fissure was manually contoured axially at regular intervals, yielding 37 contours across all patients. These contours were read into an image analysis and pattern classification system which computed a Fissure Integrity Score (FIS) for each kernel and dose. FIS values were analyzed using a mixed-effects model with kernel and dose as fixed effects and patient as random effect to test for difference due to kernel and dose. Analysis revealed no difference in FIS between the smooth kernels (B10f, B30f) nor between sharp kernels (B50f, B70f), but there was a significant difference between the sharp and smooth groups (p = 0.020). There was no significant difference in FIS between the two low-dose reconstructions (p = 0.882). Using a cutoff of 90%, the number of incomplete fissures increased from 5 to 10 when the imaging protocol changed from B50f to B30f. Reconstruction kernel has a significant effect on quantification of fissure integrity in CT. This has potential implications when selecting patients for endobronchial valve therapy.

  12. Effect of Local Crystallographic Texture on the Fissure Formation During Charpy Impact Testing of Low-Carbon Steel

    NASA Astrophysics Data System (ADS)

    Ghosh, Abhijit; Patra, Sudipta; Chatterjee, Arya; Chakrabarti, Debalay

    2016-06-01

    The severity of the formation of fissures (also known as splitting or delamination) on the fracture surface of Charpy impact-tested samples of a low-carbon steel has been found to increase with the decrease in finish rolling temperature [1093 K to 923 K (820 °C to 650 °C)]. Combined scanning electron microscopy and electron back-scattered diffraction study revealed that crystallographic texture was the prime factor responsible for the fissure formation. Through-thickness texture band composed of cube [Normal Direction (ND)║<001>] and gamma [ND║<111>] orientations developed during the inter-critical rolling treatment. Strain incompatibility between these two texture bands causes fissure cracking on the main fracture plane. A new approach based on the angle between {001} planes of neighboring crystals has been employed in order to estimate the `effective grain size,' which is used to determine the cleavage fracture stress on different planes of a sample. The severity of fissure formation was found to be directly related to the difference in cleavage fracture stress between the `main fracture plane' and `fissure plane.' Clustering of ferrite grains having cube texture promoted the fissure crack propagation along the transverse `fissure plane,' by increasing the `effective grain size' and decreasing the cleavage fracture stress on that plane.

  13. Pressure Actuated Leaf Seals for Improved Turbine Shaft Sealing

    NASA Technical Reports Server (NTRS)

    Grondahl, Clayton

    2006-01-01

    This presentation introduces a shaft seal in which leaf seal elements are constructed from slotted shim material formed and layered into a frusto-conical assembly. Limited elastic deflection of seal leaves with increasing system pressure close large startup clearance to a small, non-contacting, steady state running clearance. At shutdown seal elements resiliently retract as differential seal pressure diminishes. Large seal clearance during startup and shutdown provides a mechanism for rub avoidance. Minimum operating clearance improves performance and non-contacting operation promises long seal life. Design features of this seal, sample calculations at differential pressures up to 2400 psid and benefit comparison with brush and labyrinth seals is documented in paper, AIAA 2005 3985, presented at the Advanced Seal Technology session of the Joint Propulsion Conference in Tucson this past July. In this presentation use of bimetallic leaf material will be discussed. Frictional heating of bimetallic leaf seals during a seal rub can relieve the rub condition to some extent with a change in seal shape. Improved leaf seal rub tolerance is expected with bimetallic material.

  14. Earth-Fissure Movements Associated with Fluctuations in Ground-Water Levels near the Picacho Mountains, South-Central Arizona, 1980-84

    USGS Publications Warehouse

    Carpenter, M.C.

    1993-01-01

    The Picacho earth fissure transects subsiding alluvial sediments near the east periphery of the Picacho basin in south-central Arizona. The basin has undergone land subsidence of as much as 3.8 meters since the 1930's owing to compaction of the aquifer system in response to ground-water-Ievel declines that have exceeded 100 meters. The fissure, which extends generally north-south for 15 kilometers, exhibits horizontal tensile failure and as much as 0.6 meter of normal dip-slip movement at the land surface. The west side of the fissure is down thrown. The fissure was observed as early as 1927 and is the longest earth fissure in Arizona. Vertical and horizontal displacements were monitored along a line normal to the fissure. The survey line extends from a bedrock outcrop in the Picacho Mountains on the east, past an observation well near the fissure, to a point 1,422 meters to the west. From May 1980 to May 1984, the downthrown west side of the fissure subsided 167+-1.8 millimeters and moved 18+-1.5 millimeters westward into the basin. Concurrently, the relatively upthrown east side subsided 148+-1.8 millimeters and moved 14+-1.5 millimeters westward. Dislocation modeling of deformation along the survey line near the fissure indicates that dip-slip movement has occurred along a vertical fault surface that extends from the land surface to a depth of about 300 meters. Slip was 9 millimeters from May to December 1980 and also 9 millimeters from March to November 1981. Continuous measurements were made of horizontal movement across the fissure using a buried invar-wire horizontal extensometer, while water-level fluctuations were continuously monitored in four piezometers nested in two observation wells. The range of horizontal movement was 4.620 millimeters, and the range of water-level fluctuation in the nearest piezometer in the deep alluvium was 9.05 meters. The maximum annual opening of the fissure during the study period was 3.740 millimeters from March to October

  15. Bipolar sealing of lung parenchyma: tests in an ex vivo model.

    PubMed

    Kirschbaum, A; Clemens, A; Steinfeldt, T; Pehl, A; Meyer, C; Bartsch, D K

    2015-01-01

    Almost every pulmonary lobe resection requires cutting the lung parenchyma in the area of a lung fissure. A monopolar cutter or stapler is often used for this purpose. The seal should be absolutely airtight to prevent post-operative pulmonary fistulas. In the present study, the bipolar sealing technique was evaluated regarding air tightness of the seals during normal ventilation and its burst pressure in an ex vivo animal model. The investigations were carried out on paracardial lung lobes obtained from heart-lung preparations taken from freshly killed pigs at a slaughter house. In the laboratory, each individual lobe was perfused with Ringer's solution at body temperature and protectively ventilated through a tube (frequency: 20 1/min, p insp = 20 mbar, PEEP +5 mbar). Non-anatomic resection was carried out in the periphery of the lung lobe. The two control groups (12 lobes per group; Group 1-stapler, Group 2-parenchyma suture) were compared to three groups in which different bipolar sealing instruments were used. They were Group 3-MARSEAL(®) 10 mm (KLS Martin, Tuttlingen); Group 4-MARSEAL(®) 5 mm; and Group 5-MARCLAMP(®) (KLS Martin, Tuttlingen). The SealSafe(®) G3 electric current was used in all cases. Ventilation was continued for 20 min following parenchymal resection. Parenchymal sealing was then judged visually in a water bath and given a score (0-3). Burst pressure (mbar) was measured by increasing the inspiration pressure stepwise. Group mean values were compared (nonparametric Mann-Whitney U test, p < 0.005). Parenchymal seals were airtight under ventilation throughout the observation period in all groups. Mean burst pressures were as follows: Group 1: 47.1 ± 6.2 mbar; Group 2: 32.9 ± 3.9 mbar; Group 3: 38.8 ± 2.2 mbar; Group 4: 25.0 ± 6.4 mbar; and Group 5: 32.9 ± 5.8 mbar. Group 1, the stapler group, thus exhibited the highest burst pressures. Burst pressures for Group 3 were significantly greater than those for Group 2 (p < 0.006). Burst

  16. The economics of pit and fissure sealants in preventive dentistry: a review.

    PubMed

    Kitchens, Dinah H

    2005-08-15

    Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.

  17. Subpial Hematoma and Extravasation in the Interhemispheric Fissure with Subarachnoid Hemorrhage

    PubMed Central

    Matsuoka, Go; Abe, Kayoko; Okada, Yoshikazu; Sakai, Shuji

    2015-01-01

    A recent report on computed tomography (CT) findings of contrast extravasation in subarachnoid hemorrhage (SAH) with Sylvian hematoma suggests that the occurrence of the hematoma is secondary to bleeding in the subpial space. Our patient was in his sixties and was admitted to the hospital because of loss of consciousness (Glasgow Coma Scale E4V1M4). SAH was diagnosed in plain head CT, and growing hematomas were observed in the Sylvian and interhemispheric fissures following a subarachnoid hemorrhage. CT angiography (CTA) using a dual-phase scan protocol revealed contrast extravasation in both the fissures in the latter phase, and hematoma in the interhemispheric fissure contained multiple bleeding points. This case indicates that the occurrence of subpial hematoma such as Sylvian hematoma can be a secondary event following subpial bleeding from damaged small vessels elsewhere in the cranium. Instead of four-dimensional (4D) CT, the dual-phase CTA technique may help detect minor extravasations with usual helical CT scanner. PMID:25963159

  18. Treatment of anal fissures using a combination of minoxidil and lignocaine: a randomized, double-blind trial.

    PubMed

    Muthukumarassamy, Rajakannu; Robinson, Smile S; Sarath, Sistla Chandra; Raveendran, R

    2005-01-01

    Anal fissures are associated with hypertonia of the internal anal sphincter and pain. We evaluated the efficacy of local application of a combination of minoxidil and lignocaine in healing anal fissures. In this prospective, randomized, double-blind study, 90 patients with anal fissure were recruited. Patients received local applications of ointments containing 5% lignocaine (n=28), 0.5% minoxidil (n=36), or both (n=26). Healing of anal fissure at 6 weeks was used as the primary end-point. Rates of complete healing of fissure were similar in the three groups (lignocaine alone 8/27, minoxidil alone 10/34, combination 7/22; p=ns). Mean (SD) time taken for complete healing with combination treatment [1.9 (0.6) weeks] was significantly shorter than that with minoxidil alone (3.1 [1.7] weeks; p=0.001) or with lignocaine alone (3.3 [0.8] weeks; p=0.002). Rates of pain relief were similar in the three groups. Stoppage of bleeding occurred more often with combination treatment than with lignocaine alone. No patient had systemic or local side effects. Combination treatment with minoxidil and lignocaine helps in faster healing of anal fissures and provides better symptomatic relief than either drug alone.

  19. Aortocoronary dissection with acute left main artery occlusion: successful treatment with emergent stenting.

    PubMed

    Wykrzykowska, Joanna J; Carrozza, Joseph; Laham, Roger J

    2006-08-01

    Iatrogenic aortocoronary dissection is a rare but devastating complication of percutaneous coronary interventions and cardiac surgery, with a mortality rate up to 35%. Of the type-A dissections in the International Registry of Aortic Dissections (IRAD), 27% were caused by coronary interventions. The mechanism involves an initial dissection in the coronary artery, which then propagates in a retrograde fashion past the sinuses of Valsalva, often several centimeters beyond the aortic valve. With the advent of complex interventions such as left main stent implantation, revascularization of chronic total occlusions and mechanical thrombectomy, this complication may become more prevalent. Here we present a unique case of percutaneous coronary intervention (PCI) of the left circumflex (LCx) artery complicated by a left main coronary dissection that propagated approximately 8 cm into the ascending aorta and caused abrupt left main coronary artery occlusion and hemodynamic collapse. Rescue of the left main artery and sealing of the aortic dissection with stabilization of the patient was possible with rapid ostial left main artery stenting.

  20. Long Term Outcome after Application of the Angio-Seal Vascular Closure Device in Minipigs

    PubMed Central

    Kabelitz, Lisa; Nonn, Andrea; Nolte, Kay W.; Nikoubashman, Omid; Othman, Ahmed; Heringer, Sarah; Kramer, Martin; Wiesmann, Martin; Brockmann, Marc A.

    2016-01-01

    Minipigs are frequently used in (neuro-)interventional research. Longitudinal experiments may require repeated vessel access via the femoral artery. Anticoagulation and incompliance of the animals necessitates the use of a vascular closure device (VCD). The effects of the Angio-Seal VCD in minipigs were longitudinally assessed. Minipig (42±8.4 kg body weight) femoral arteries were sealed using the 8F (n = 6) or 6F (n = 7) Angio-Seal VCD. The pre-interventional femoral artery diameter was 5.1±0.4 mm (4.3–5.8 mm). Sealed puncture sites were analysed angiographically as well as by computed tomography angiography (CTA) for a mean period of 14.1±8.0 weeks (1–22 weeks). All animals were constantly treated with acetylsalicylic acid (ASS) (450 mg/d (n = 7) or 100 mg/d (n = 1)) and clopidogrel (75 mg/d (n = 8)). Non-instrumented (n = 2) and arteries sealed using the VCD (n = 2) were examined histologically. No postoperative hemorrhagic complications were observed. Three arteries were occluded after VCD placement (1 animal diagnosed after 4 weeks (8F), 2 animals after 1 week (6F)) and remained so until the end of the experiments after 22, 12 and 4 weeks, respectively. In one artery a 50% stenosis 8 weeks after application of a 6F Angio-Seal was detected. In 69.2% (n = 9) the VCD was applied without complications. Histopathological analysis of the sealed arterial segments showed subtotal obliteration of the vessel lumen, formation of collagenous tissue and partial damage of the internal elastic lamina. The Angio-Seal VCD prevents relevant hemorrhagic complications in minipigs treated with dual platelet inhibition, but is associated with increased vessel occlusion rates. PMID:27682594

  1. Sealing device for providing a seal in a turbomachine

    DOEpatents

    Lacy, Benjamin Paul; Kottilingam, Srikanth Chandrudu; Porter, Christopher Donald; Schick, David Edward; Weber, David Wayne

    2016-08-16

    Sealing device for providing seals between adjacent components, and turbomachines utilizing such sealing devices, are provided. A sealing device includes a seal plate insertable between the adjacent components, the seal plate comprising a first face and an opposing second face. The sealing device further includes a plurality of pins extending from one of the first face or the second face, the plurality of pins configured to space the one of the first face or the second face from contact surfaces of the adjacent components.

  2. Titanium sealing glasses and seals formed therefrom

    DOEpatents

    Brow, Richard K.; McCollister, Howard L.; Phifer, Carol C.; Day, Delbert E.

    1997-01-01

    Alkaline-earth lanthanoborate sealing-glass compositions containing CaO, La.sub.2 O.sub.3, B.sub.2 O.sub.3, TiO.sub.2 and Al.sub.2 O.sub.3 in various combinations of mole-% are provided. These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys that have a high aqueous durability for component or device applications requiring exposure to moisture, water or body fluids. Particular applications of the titanium sealing-glass compositions include forming glass-to-metal seals for lithium batteries and implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps).

  3. Focal dilation and paradoxical collapse of cortical fissures and sulci in patients with normal-pressure hydrocephalus.

    PubMed

    Holodny, A I; George, A E; de Leon, M J; Golomb, J; Kalnin, A J; Cooper, P R

    1998-11-01

    The authors describe a subgroup of patients with shunt-proven normal-pressure hydrocephalus (NPH) who presented with focal fissural and sulcal dilation on imaging studies. The specific radiological features and methods of differentiating this condition from cortical atrophy are delineated. Normal-pressure hydrocephalus has been described as dilation of the ventricles that is out of proportion to the sulci. Sulcal dilation has been taken as evidence of cortical atrophy and has even been used as a criterion to exclude patients from undergoing a shunting procedure. The authors describe five cases of patients with shunt-proven NPH who presented with focal dilation of cortical fissures and sulci. In three of the cases, there was a paradoxical decrease in the size of the dilated fissures and sulci that paralleled the decrease in the size of the lateral ventricles following successful shunting. This study demonstrates that focal fissural and sulcal dilation may represent reservoirs of cerebrospinal fluid analogous to the ventricular system. Patients should not be denied a shunting procedure solely on the basis of focally dilated fissures of sulci.

  4. Seal assembly

    DOEpatents

    Johnson, Roger Neal; Longfritz, William David

    2001-01-01

    A seal assembly that seals a gap formed by a groove comprises a seal body, a biasing element, and a connection that connects the seal body to the biasing element to form the seal assembly. The seal assembly further comprises a concave-shaped center section and convex-shaped contact portions at each end of the seal body. The biasing element is formed from an elastic material and comprises a convex-shaped center section and concave-shaped biasing zones that are opposed to the convex-shaped contact portions. The biasing element is adapted to be compressed to change a width of the seal assembly from a first width to a second width that is smaller than the first width. In the compressed state, the seal assembly can be disposed in the groove. After release of the compressing force, the seal assembly expands. The contact portions will move toward a surface of the groove and the biasing zones will move into contact with another surface of the groove. The biasing zones will bias the contact portions of the seal body against the surface of the groove.

  5. Aspirating Seal Development: Analytical Modeling and Seal Test Rig

    NASA Technical Reports Server (NTRS)

    Bagepalli, Bharat

    1996-01-01

    This effort is to develop large diameter (22 - 36 inch) Aspirating Seals for application in aircraft engines. Stein Seal Co. will be fabricating the 36-inch seal(s) for testing. GE's task is to establish a thorough understanding of the operation of Aspirating Seals through analytical modeling and full-scale testing. The two primary objectives of this project are to develop the analytical models of the aspirating seal system, to upgrade using GE's funds, GE's 50-inch seal test rig for testing the Aspirating Seal (back-to-back with a corresponding brush seal), test the aspirating seal(s) for seal closure, tracking and maneuver transients (tilt) at operating pressures and temperatures, and validate the analytical model. The objective of the analytical model development is to evaluate the transient and steady-state dynamic performance characteristics of the seal designed by Stein. The transient dynamic model uses a multi-body system approach: the Stator, Seal face and the rotor are treated as individual bodies with relative degrees of freedom. Initially, the thirty-six springs are represented as a single one trying to keep open the aspirating face. Stops (Contact elements) are provided between the stator and the seal (to compensate the preload in the fully-open position) and between the rotor face and Seal face (to detect rub). The secondary seal is considered as part of the stator. The film's load, damping and stiffness characteristics as functions of pressure and clearance are evaluated using a separate (NASA) code GFACE. Initially, a laminar flow theory is used. Special two-dimensional interpolation routines are written to establish exact film load and damping values at each integration time step. Additionally, other user-routines are written to read-in actual pressure, rpm, stator-growth and rotor growth data and, later, to transfer these as appropriate loads/motions in the system-dynamic model. The transient dynamic model evaluates the various motions, clearances

  6. Acoustic Seal

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor)

    2006-01-01

    The invention relates to a sealing device having an acoustic resonator. The acoustic resonator is adapted to create acoustic waveforms to generate a sealing pressure barrier blocking fluid flow from a high pressure area to a lower pressure area. The sealing device permits noncontacting sealing operation. The sealing device may include a resonant-macrosonic-synthesis (RMS) resonator.

  7. Acoustic seal

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor)

    2006-01-01

    The invention relates to a sealing device having an acoustic resonator. The acoustic resonator is adapted to create acoustic waveforms to generate a sealing pressure barrier blocking fluid flow from a high pressure area to a lower pressure area. The sealing device permits noncontacting sealing operation. The sealing device may include a resonant-macrosonic-synthesis (RMS) resonator.

  8. Hawaiian fissure fountains 1: decoding deposits-episode 1 of the 1969-1974 Mauna Ulu eruption

    USGS Publications Warehouse

    Parcheta, C.E.; Houghton, Bruce F.; Swanson, D.A.

    2012-01-01

    Deposits from episode 1 of the 1969–1974 Mauna Ulu eruption of Kīlauea provide an exceptional opportunity to study processes of low intensity Hawaiian fissure fountains. Episode 1 lava flows passed through dense forest that had little impact on flow dynamics; in contrast, the pattern of spatter preservation was strongly influenced by the forest (through the formation of tree molds) and the preexisting topography. A low, near-continuous spatter rampart is present upwind and upslope, on the north side of the fissure. Most of the pyroclastic products, however, fell downwind to the south of the fissure, but little was preserved due to two processes: (1) incorporation of proximal spatter in rheomorphic lava flows 10–20 m from the vents, and (2) the downslope transport of cooler spatter falling on top of these flows beyond 20 m from vent. The lava flow field itself shows a complex history. Initially, discharge from the fissure exceeded the transport capacity of the southern drainage pathways, and lava ponded dynamically to a maximum height of 4 m for 40–120 min, until fountains began to decline. During declining discharge, lava flowed both southward away from the fissure and increasingly back into the vents. There is a clear “lava-shed” or delineation between where lava drained northwards back into the fissure, and where it continued flowing to the south. The 1969 deposits suggest that care is needed when products of less well-documented eruptions are analyzed, as postdepositional transport of spatter may preclude the formation of classic paired (symmetrical) ramparts.

  9. Deformation Associated With the July 21 Fissure Eruption at Kilauea Volcano, Hawai`i

    NASA Astrophysics Data System (ADS)

    Poland, M.; Orr, T.; Miklius, A.

    2007-12-01

    Deformation measurements at the Pu`u `O`o cone on Kilauea volcano indicate that the vent is underlain by a shallow magma storage reservoir fed by magma transported from Kilauea's summit. The Pu`u `O`o reservoir was drained during the "Father's&pDay" intrusion of June 17-19, 2007, causing Pu`u `O`o's floor to collapse. Following the intrusion, the reservoir gradually refilled and lava reappeared on July 1-2. A lava lake grew in the crater during July 2-20, steadily raising the elevation of the crater floor. The crater interior and adjoining walls began to uplift on July 10, and 2 days later lava began to vent above the level of the lava lake along the margins of the crater. The number of crater margin vents and the magnitude of their activity increased until July 21, by which time crater uplift amounted to about 8 meters. Early that morning, the lava pond at Pu`u `O`o drained suddenly and an eruptive fissure opened on the east flank of the cone. The fissure propagated 2 km downrift, and within a few hours the eruption had localized on three fissure segments between 1 and 2 km east of Pu`u `O`o. Lava erupting from this series of vents formed a system of perched lava ponds feeding long `a`a flows. Deformation associated with the July 21 fissure was exceptionally well-documented by a borehole tiltmeter on the north flank of Pu`u `O`o and 7 continuous GPS stations within 2 km of the cone (the fissure propagated between two of these GPS stations). The time series of geodetic measurements suggests that deflation of Pu`u `O`o began at about 2250 HST (Hawaiian Standard Time - UTC minus 10 hours) on July 20, while a camera looking into Pu`u `O`o crater recorded draining of the lava lake starting at around 2355 HST. Deformation associated with opening of the fissure was apparent in the tilt and GPS records by 0012 HST, with the camera showing glow in the direction of the eruption site by 0039 HST on July 21. Localized deformation from InSAR suggests that the fissure has a

  10. Cyp1b1 Regulates Ocular Fissure Closure Through a Retinoic Acid–Independent Pathway

    PubMed Central

    Williams, Antionette L.; Eason, Jessica; Chawla, Bahaar; Bohnsack, Brenda L.

    2017-01-01

    Purpose Mutations in the CYP1B1 gene are the most commonly identified genetic causes of primary infantile-onset glaucoma. Despite this disease association, the role of CYP1B1 in eye development and its in vivo substrate remain unknown. In the present study, we used zebrafish to elucidate the mechanism by which cyp1b1 regulates eye development. Methods Zebrafish eye and neural crest development were analyzed using live imaging of transgenic zebrafish embryos, in situ hybridization, immunostaining, TUNEL assay, and methylacrylate sections. Cyp1b1 and retinoic acid (RA) levels were genetically (morpholino oligonucleotide antisense and mRNA) and pharmacologically manipulated to examine gene function. Results Using zebrafish, we observed that cyp1b1 was expressed in a specific spatiotemporal pattern in the ocular fissures of the developing zebrafish retina and regulated fissure patency. Decreased Cyp1b1 resulted in the premature breakdown of laminin in the ventral fissure and altered subsequent neural crest migration into the anterior segment. In contrast, cyp1b1 overexpression inhibited cell survival in the ventral ocular fissure and prevented fissure closure via an RA-independent pathway. Cyp1b1 overexpression also inhibited the ocular expression of vsx2, pax6a, and pax6b and increased the extraocular expression of shha. Importantly, embryos injected with human wild-type but not mutant CYP1B1 mRNA also showed colobomas, demonstrating the evolutionary and functional conservation of gene function between species. Conclusions Cyp1b1 regulation of ocular fissure closure indirectly affects neural crest migration and development through an RA-independent pathway. These studies provide insight into the role of Cyp1b1 in eye development and further elucidate the pathogenesis of primary infantile-onset glaucoma. PMID:28192799

  11. Titanium sealing glasses and seals formed therefrom

    DOEpatents

    Brow, R.K.; McCollister, H.L.; Phifer, C.C.; Day, D.E.

    1997-12-02

    Alkaline-earth lanthanoborate sealing-glass compositions containing CaO, La{sub 2}O{sub 3}, B{sub 2}O{sub 3}, TiO{sub 2} and Al{sub 2}O{sub 3} in various combinations of mole-% are provided. These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys that have a high aqueous durability for component or device applications requiring exposure to moisture, water or body fluids. Particular applications of the titanium sealing-glass compositions include forming glass-to-metal seals for lithium batteries and implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps). 2 figs.

  12. Multilayer compressive seal for sealing in high temperature devices

    DOEpatents

    Chou, Yeong-Shyung [Richland, WA; Stevenson, Jeffry W [Richland, WA

    2007-08-21

    A mica based compressive seal has been developed exhibiting superior thermal cycle stability when compared to other compressive seals known in the art. The seal is composed of compliant glass or metal interlayers and a sealing (gasket) member layer composed of mica that is infiltrated with a glass forming material, which effectively reduces leaks within the seal. The compressive seal shows approximately a 100-fold reduction in leak rates compared with previously developed hybrid seals after from 10 to about 40 thermal cycles under a compressive stress of from 50 psi to 100 psi at temperatures in the range from 600.degree. C. to about 850.degree. C.

  13. Sealing device

    DOEpatents

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  14. The effects of dietary biotin supplementation on vertical fissures of the claw wall in beef cattle.

    PubMed Central

    Campbell, J R; Greenough, P R; Petrie, L

    2000-01-01

    A clinical field trial was performed on a herd of Hereford beef cows in central Saskatchewan. The herd had a history of being severely affected with vertical fissures. The objective of the study was to determine the effects of supplemental dietary biotin on the prevalence of vertical fissures in beef cows. In June 1994 and June 1995, 1- and 2-year-old heifers were randomly allocated into 2 treatment groups, each composed of 79 animals. One group received a 10 mg/head/day biotin-supplemented free-choice mineral supplement, while the other groups received an identical free-choice mineral without the biotin supplementation. The claws from these animals were evaluated in June 1994, October 1994, June 1995, October 1995, and June 1996 for the presence of vertical fissures. Supplemental dietary biotin significantly increased serum levels of biotin and significantly increased claw hardness in supplemented cows. Both groups of heifers started the trial without vertical fissures. After 18 months, 15% of the cows fed supplemental dietary biotin had vertical fissures compared with 33% in the nonsupplemented group. The difference was statistically significant (P = 0.01). PMID:10992986

  15. Anal sphincter fibrillation: is this a new finding that identifies resistant chronic anal fissures that respond to botulinum toxin?

    PubMed

    Moon, A; Chitsabesan, P; Plusa, S

    2013-08-01

    Anal fissures can be resistant to treatment and some patients may undergo several trials of medical therapy before definitive surgery. It would be useful to identify predictors of poor response to medical therapy. This study assesses the role of anorectal physiological criteria to identify patients with anal fissure predicted to fail botulinum toxin (BT) treatment. A retrospective analysis of anorectal physiological data collected for patients with resistant chronic anal fissures, referred to one consultant surgeon between 2007 and 2011, was undertaken. These were correlated with treatment plans and healing rates. Twenty-five patients with idiopathic chronic anal fissures underwent anorectal physiology studies and were subsequently treated with BT injection. Eleven had a characteristic high-frequency low-amplitude 'saw tooth' waveform or anal sphincter fibrillation (ASF) and higher anal sphincter pressures. Nine (82%) of these patients had resolution of their anal fissure symptoms following treatment with BT. Of 14 patients with no evidence of ASF and a greater range of anal sphincter pressures, only one (7%) had resolution following BT. ASF appears to be an anorectal physiological criterion that helps predict response of anal fissures to BT injection. This could help streamline fissure management. © 2013 The Authors. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  16. Evaluation of dentin tubule occlusion after laser irradiation and desensitizing agent application.

    PubMed

    Kim, Min-Ho; Kim, Ryan Jin-Young; Lee, Woo-Cheol; Lee, In-Bog

    2015-10-01

    To evaluate the effects of lasers (Nd:YAG and Er:YAG) and of topical desensitizing agents on dentin tubule occlusion by measuring real-time dentin fluid flow (DFF). 32 molars were prepared with V-shape cavity at the cervical area, acid-etched, water rinsed, blotted dry, and treated with (1) Nd:YAG laser; (2) Er:YAG laser; (3) SuperSeal, a desensitizing agent; (4) ClinproXT, a resin-modified glass-ionomer (RMGI) varnish (n = 8 each). A real-time fluid flow measuring instrument (nano-Flow) was used to measure the DFF throughout the procedures. The DFF rates before and after the treatment were compared. Moreover, the surface topography of dentin tubules after each desensitizing method was examined using SEM. DFF varied among the groups. The DFF rate was significantly reduced after laser irradiation/application of the desensitizing agents (P < 0.05). ClinproXT showed the greatest reduction of DFF rate (71.9%), followed by the SuperSeal (34.8%) and laser groups (P< 0.05). However, there was no significant difference between the Nd:YAG (24.1%) and Er:YAG (20.6%) groups (P > 0.05). In SEM images, narrowed dentin tubules were observed in both lased groups and SuperSeal group. In the ClinproXT group, the occluded dentin tubules by the RMGI covering were observed.

  17. A comparison between three different pit and fissure sealants with regard to marginal integrity.

    PubMed

    Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen

    2012-04-01

    THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.

  18. An Experimental and Numerical Study on Cracking Behavior of Brittle Sandstone Containing Two Non-coplanar Fissures Under Uniaxial Compression

    NASA Astrophysics Data System (ADS)

    Yang, Sheng-Qi; Tian, Wen-Ling; Huang, Yan-Hua; Ranjith, P. G.; Ju, Yang

    2016-04-01

    To understand the fracture mechanism in all kinds of rock engineering, it is important to investigate the fracture evolution behavior of pre-fissured rock. In this research, we conducted uniaxial compression experiments to evaluate the influence of ligament angle on the strength, deformability, and fracture coalescence behavior of rectangular prismatic specimens (80 × 160 × 30 mm) of brittle sandstone containing two non-coplanar fissures. The experimental results show that the peak strength of sandstone containing two non-coplanar fissures depends on the ligament angle, but the elastic modulus is not closely related to the ligament angle. With the increase of ligament angle, the peak strength decreased at a ligament angle of 60°, before increasing up to our maximum ligament angle of 120°. Crack initiation, propagation, and coalescence were all observed and characterized from the inner and outer tips of pre-existing non-coplanar fissures using photographic monitoring. Based on the results, the sequence of crack evolution in sandstone containing two non-coplanar fissures was analyzed in detail. In order to fully understand the crack evolution mechanism of brittle sandstone, numerical simulations using PFC2D were performed for specimens containing two non-coplanar fissures under uniaxial compression. The results are in good agreement with the experimental results. By analyzing the stress field, the crack evolution mechanism in brittle sandstone containing two non-coplanar fissures under uniaxial compression is revealed. These experimental and numerical results are expected to improve the understanding of the unstable fracture mechanism of fissured rock engineering structures.

  19. Optimization of the static occlusion by "occlusal surface settling" in the Cerec 3D software.

    PubMed

    Späth, C; Kordass, B

    2006-04-01

    The adjustment of the static occlusion can be automated in computer-based systems. The Cerec 3D software makes it possible to take preformed occlusal surfaces from a database and adapt them to the antagonist. In this adaptation (settling), the CAD occlusal surface "settles" as whole or each cusp individually into the occlusal surface of the antagonist until stable occlusion is reached. Two occlusal surface shapes were compared: Vita Physiodens and Lee Culp. An index was formed from the number, quality, and position of the occlusal contacts for 35 model cases (25 molars, 10 premolars). With regard to the settling of the total occlusal surfaces, there were no differences between the two occlusal surface shapes. In "cusp settling" of the molars, Vita Physiodens performed significantly better. In the comparison of the 1st with the 3rd settling process, significant improvements occurred the 3rd time in many cases when settling individual cusps, but in clearly fewer cases in the settling process of the total occlusal surface. The Lee Culp tooth occlusion improved especially after the 3rd settling process of individual cusps. It is therefore expedient to combine both settling versions with one another.

  20. Coining seal

    DOEpatents

    Mancebo, Lloyd

    1976-01-01

    A bakeable high pressure-vacuum seal is provided in which an inductile sealing element having a butterfly shaped crosssection with protruding sharp edges at each of the four corners, is sandwiched between two ductile sealing elements, the sandwiched assembly then being compressed between the surfaces of the flange elements of a high pressure or high vacuum vessel to coin the ductile sealing element into the surface of the inductile sealing element as well as the surfaces of the flange elements.

  1. Monitoring of land subsidence and ground fissures in Xian, China 2005-2006: Mapped by sar Interferometry

    USGS Publications Warehouse

    Zhao, C.Y.; Zhang, Q.; Ding, X.-L.; Lu, Z.; Yang, C.S.; Qi, X.M.

    2009-01-01

    The City of Xian, China, has been experiencing significant land subsidence and ground fissure activities since 1960s, which have brought various severe geohazards including damages to buildings, bridges and other facilities. Monitoring of land subsidence and ground fissure activities can provide useful information for assessing the extent of, and mitigating such geohazards. In order to achieve robust Synthetic Aperture Radar Interferometry (InSAR) results, six interferometric pairs of Envisat ASAR data covering 2005–2006 are collected to analyze the InSAR processing errors firstly, such as temporal and spatial decorrelation error, external DEM error, atmospheric error and unwrapping error. Then the annual subsidence rate during 2005–2006 is calculated by weighted averaging two pairs of D-InSAR results with similar time spanning. Lastly, GPS measurements are applied to calibrate the InSAR results and centimeter precision is achieved. As for the ground fissure monitoring, five InSAR cross-sections are designed to demonstrate the relative subsidence difference across ground fissures. In conclusion, the final InSAR subsidence map during 2005–2006 shows four large subsidence zones in Xian hi-tech zones in western, eastern and southern suburbs of Xian City, among which two subsidence cones are newly detected and two ground fissures are deduced to be extended westward in Yuhuazhai subsidence cone. This study shows that the land subsidence and ground fissures are highly correlated spatially and temporally and both are correlated with hi-tech zone construction in Xian during the year of 2005–2006.

  2. High temperature braided rope seals for static sealing applications

    NASA Technical Reports Server (NTRS)

    Adams, Michael L.; Olsen, Andrew; Darolia, Ram; Steinetz, Bruce M.; Bartolotta, Paul A.

    1996-01-01

    Achieving efficiency and performance goals of advanced aircraft and industrial systems are leading designers to implement high temperature materials such as ceramics and intermetallics. Generally these advanced materials are applied selectively in the highest temperature sections of the engine system including the combustor and high pressure turbine, amongst others. Thermal strains that result in attaching the low expansion-rate components to high expansion rate superalloy structures can cause significant life reduction in the components. Seals are being designed to both seal and to serve as compliant mounts allowing for relative thermal growths between high temperature but brittle primary structures and the surrounding support structures. Designers require high temperature, low-leakage, compliant seals to mitigate thermal stresses and control parasitic and cooling airflow between structures. NASA is developing high temperature braided rope seals in a variety of configurations to help solve these problems. This paper will describe the types of seals being developed, describe unique test techniques used to assess seal performance, and present leakage flow data under representative pressure, temperature and scrubbing conditions. Feasibility of the braided rope seals for both an industrial tube seal and a turbine vane seal application is also demonstrated.

  3. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...

  4. 21 CFR 872.3765 - Pit and fissure sealant and conditioner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...

  5. Medical and surgical treatment of haemorrhoids and anal fissure in Crohn's disease: a critical appraisal.

    PubMed

    D'Ugo, Stefano; Franceschilli, Luana; Cadeddu, Federica; Leccesi, Laura; Blanco, Giovanna Del Vecchio; Calabrese, Emma; Milito, Giovanni; Di Lorenzo, Nicola; Gaspari, Achille L; Sileri, Pierpaolo

    2013-03-11

    The principle to avoid surgery for haemorrhoids and/or anal fissure in Crohn's disease (CD) patients is still currently valid despite advances in medical and surgical treatments. In this study we report our prospectively recorded data on medical and surgical treatment of haemorrhoids and anal fissures in CD patients over a period of 8 years. Clinical data of patients affected by perianal disease were routinely and prospectively inserted in a database between October 2003 and October 2011 at the Department of Surgery, Tor Vergata University Hospital, Rome. We reviewed and divided in two groups records on CD patients treated either medically or surgically according to the diagnosis of haemorrhoids or anal fissures. Moreover, we compared in each group the outcome in patients with prior diagnosis of CD and in patients diagnosed with CD only after perianal main treatment. Eighty-six CD patients were included in the study; 45 were treated for haemorrhoids and 41 presented with anal fissure. Conservative approach was initially adopted for all patients; in case of medical treatment failure, the presence of stable intestinal disease made them eligible for surgery. Fifteen patients underwent haemorrhoidectomy (open 11; closed 3; stapled 1), and two rubber band ligation. Fourteen patients required surgery for anal fissure (Botox ± fissurectomy 8; LIS 6). In both groups we observed high complication rate, 41.2% for haemorrhoids and 57.1% for anal fissure. Patients who underwent haemorrhoidectomy without certain diagnosis of CD had significantly higher risk of complications. Conservative treatment of proctologic diseases in CD patients has been advocated given the high risk of complications and the evidence that spontaneous healing may also occur. From these preliminary results a role of surgery is conceivable in high selected patients, but definitve conclusions can't be made. Further randomized trials are needed to establish the efficacy of the surgical approach, giving

  6. Mechanical seal assembly

    DOEpatents

    Kotlyar, Oleg M.

    2001-01-01

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transferring it to the mechanical diode.

  7. Mechanical seal assembly

    DOEpatents

    Kotlyar, Oleg M.

    2002-01-01

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transfering it to the mechanical diode.

  8. Tracer Movement in a Single Fissure in Granitic Rock: Some Experimental Results and Their Interpretation

    NASA Astrophysics Data System (ADS)

    Neretnieks, Ivars; Eriksen, Tryggve; TäHtinen, PäIvi

    1982-08-01

    Radionuclide migration was studied in a natural fissure in a granite core. The fissure was oriented parallel to the axis in a cylindrical core 30 cm long and 20 cm in diameter. The traced solution was injected at one end of the core and collected at the other. Breakthrough curves were obtained for the nonsorbing tracers, tritiated water, and a large-molecular-weight lignosulphonate molecule and for the sorbing tracers, cesium and strontium. From the breakthrough curves for the nonsorbing tracers it could be concluded that channeling occurs in the single fissure. A `dispersion' model based on channeling is presented. The results from the sorbing tracers indicate that there is substantial diffusion into and sorption in the rock matrix. Sorption on the surface of the fissure also accounts for a part of the retardation effect of the sorbing species. A model which includes the mechanisms of channeling, surface sorption, matrix diffusion, and matrix sorption is presented. The experimental breakthrough curves can be fitted fairly well by this model by use of independently obtained data on diffusivities and matrix sorption.

  9. Glass sealing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brow, R.K.; Kovacic, L.; Chambers, R.S.

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  10. Rotary kiln seal

    DOEpatents

    Drexler, Robert L.

    1992-01-01

    A rotary seal used to prevent the escape of contaminates from a rotating kiln incinerator. The rotating seal combines a rotating disc plate which is attached to the rotating kiln shell and four sets of non-rotating carbon seal bars housed in a primary and secondary housing and which rub on the sides of the disc. A seal air system is used to create a positive pressure in a chamber between the primary and secondary seals to create a positive air flow into the contaminated gas chamber. The seal air system also employs an air inlet located between the secondary and tertiary seals to further insure that no contaminates pass the seal and enter the external environment and to provide makeup air for the air which flows into the contaminated gas chamber. The pressure exerted by the seal bars on the rotating disc is controlled by means of a preload spring. The seal is capable of operating in a thermally changing environment where the both radial expansion and axial movement of the rotating kiln do not result in the failure of the seal.

  11. Sylvian fissure lipoma with angiomatous component and associated brain malformation: A case report.

    PubMed

    Thakur, Shruti; Sood, Ram Gopal; Jhobta, Anupam; Makhaik, Sushma; Thakur, Charusmita

    2013-01-01

    Intracranial lipomas are congenital malformations. These uncommon lesions have an incidence of 0.1 to 1.7% of all intracranial tumors. Most cases are located at midline and 5% are along the sylvian fissures. If symptomatic, seizures are the most common symptom. These tumors are slow growing and have favorable outcome. We report a case of a 25-year-old man whose CT and MRI revealed a lesion in right sylvian fissure suggesting a lipoma with abnormal vasculature and overlying cortical dysplasia.

  12. Impact de la preparation des anodes crues et des conditions de cuisson sur la fissuration dans des anodes denses

    NASA Astrophysics Data System (ADS)

    Amrani, Salah

    La fabrication de l'aluminium est realisee dans une cellule d'electrolyse, et cette operation utilise des anodes en carbone. L'evaluation de la qualite de ces anodes reste indispensable avant leur utilisation. La presence des fissures dans les anodes provoque une perturbation du procede l'electrolyse et une diminution de sa performance. Ce projet a ete entrepris pour determiner l'impact des differents parametres de procedes de fabrication des anodes sur la fissuration des anodes denses. Ces parametres incluent ceux de la fabrication des anodes crues, des proprietes des matieres premieres et de la cuisson. Une recherche bibliographique a ete effectuee sur tous les aspects de la fissuration des anodes en carbone pour compiler les travaux anterieurs. Une methodologie detaillee a ete mise au point pour faciliter le deroulement des travaux et atteindre les objectifs vises. La majorite de ce document est reservee pour la discussion des resultats obtenus au laboratoire de l'UQAC et au niveau industriel. Concernant les etudes realisees a l'UQAC, une partie des travaux experimentaux est reservee a la recherche des differents mecanismes de fissuration dans les anodes denses utilisees dans l'industrie d'aluminium. L'approche etait d'abord basee sur la caracterisation qualitative du mecanisme de la fissuration en surface et en profondeur. Puis, une caracterisation quantitative a ete realisee pour la determination de la distribution de la largeur de la fissure sur toute sa longueur, ainsi que le pourcentage de sa surface par rapport a la surface totale de l'echantillon. Cette etude a ete realisee par le biais de la technique d'analyse d'image utilisee pour caracteriser la fissuration d'un echantillon d'anode cuite. L'analyse surfacique et en profondeur de cet echantillon a permis de voir clairement la formation des fissures sur une grande partie de la surface analysee. L'autre partie des travaux est basee sur la caracterisation des defauts dans des echantillons d'anodes crues

  13. Mechanical Behavior of Brittle Rock-Like Specimens with Pre-existing Fissures Under Uniaxial Loading: Experimental Studies and Particle Mechanics Approach

    NASA Astrophysics Data System (ADS)

    Cao, Ri-hong; Cao, Ping; Lin, Hang; Pu, Cheng-zhi; Ou, Ke

    2016-03-01

    Joints and fissures with similar orientation or characteristics are common in natural rocks; the inclination and density of the fissures affect the mechanical properties and failure mechanism of the rock mass. However, the strength, crack coalescence pattern, and failure mode of rock specimens containing multi-fissures have not been studied comprehensively. In this paper, combining similar material testing and discrete element numerical method (PFC2D), the peak strength and failure characteristics of rock-like materials with multi-fissures are explored. Rock-like specimens were made of cement and sand and pre-existing fissures created by inserting steel shims into cement mortar paste and removing them during curing. The peak strength of multi-fissure specimens depends on the fissure angle α (which is measured counterclockwise from horizontal) and fissure number ( N f). Under uniaxial compressional loading, the peak strength increased with increasing α. The material strength was lowest for α = 25°, and highest for α = 90°. The influence of N f on the peak strength depended on α. For α = 25° and 45°, N f had a strong effect on the peak strength, while for higher α values, especially for the 90° sample, there were no obvious changes in peak strength with different N f. Under uniaxial compression, the coalescence modes between the fissures can be classified into three categories: S-mode, T-mode, and M-mode. Moreover, the failure mode can be classified into four categories: mixed failure, shear failure, stepped path failure, and intact failure. The failure mode of the specimen depends on α and N f. The peak strength and failure modes in the numerically simulated and experimental results are in good agreement.

  14. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms.

    PubMed

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-12-01

    The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as "decreased," "slightly decreased," and "preserved". Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P<0.001) between the two groups. HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group (33.8 ± 8.2 HU vs. 11.9 ± 6.1 HU, P<0.001). There was no significant difference in HUs for the entire lesion between the non-occlusive (33.8 ± 8.2 HU) and corresponding normal group (34.5 ± 6.8 HU; P=0.294). Iodine perfusion tended to be visually and quantitatively preserved in lungs with

  15. Nozzle seal

    DOEpatents

    Groff, Russell Dennis; Vatovec, Richard John

    1978-06-11

    In an illustrative embodiment of the invention, a nuclear reactor pressure vessel, having an internal hoop from which the heated coolant emerges from the reactor core and passes through to the reactor outlet nozzles, is provided with annular sealing members operatively disposed between the outlet nozzle and the hoop and partly within a retaining annulus formed in the hoop. The sealing members are biased against the pressure vessel and the hoop and one of the sealing members is provided with a piston type pressure ring sealing member which effectively closes the path between the inlet and outlet coolants in the region about the outlet nozzle establishing a leak-proof condition. Furthermore, the flexible responsiveness of the seal assures that the seal will not structurally couple the hoop to the pressure vessel.

  16. Regenerator seal design

    DOEpatents

    Eckart, Francis H.

    1982-01-01

    A rotary regenerator disc matrix has a face seal with a cross arm and arcuate rim segments joined by prestress clamps to prestrain the arcuate rim seals so as to compensate seal rim twisting or coning and resultant disc face seal leakage as produced by operating thermal gradients across the seal.

  17. Response of rock-fissure seepage to snowmelt in Mount Taihang slope-catchment, North China.

    PubMed

    Cao, Jiansheng; Liu, Changming; Zhang, Wanjun

    2013-01-01

    The complex physiographic and hydrogeological systems of mountain terrains facilitate intense rock-fissure seepages and multi-functional ecological interactions. As mountain eco-hydrological terrains are the common water sources of river basins across the globe, it is critical to build sufficient understanding into the hydrological processes in this unique ecosystem. This study analyzes infiltration and soil/rock-fissure seepage processes from a 65 mm snowfall/melt in November 2009 in the typical granitic gneiss slope catchment in the Taihang Mountains. The snowfall, snowmelt and melt-water processes are monitored using soil-water time-domain reflectometry (TDR) probes and tipping bucket flowmeters. The results suggest that snowmelt infiltration significantly influences soil/rock water seepage in the 0-100 cm soil depth of the slope-catchment. It is not only air temperature that influences snowmelt, but also snowmelt infiltration and rock-fissure seepage. Diurnal variations in rock-fissure seepage are in close correlation with air temperature (R(2) > 0.7). Temperature also varies with soil/rock water viscosity, which element in turn influences soil/rock water flow. Invariably, water dynamics in the study area is not only a critical water supply element for domestic, industrial and agricultural uses, but also for food security and social stability.

  18. Conformable seal

    DOEpatents

    Neef, W.S.; Lambert, D.R.

    1982-08-10

    Sealing apparatus and method, comprising first and second surfaces or membranes, at least one of which surfaces is deformable, placed in proximity to one another. Urging means cause these surfaces to contact one another in a manner such that the deformable surface deforms to conform to the geometry of the other surface, thereby creating a seal. The seal is capable of undergoing multiple cycles of sealing and unsealing.

  19. Randomized clinical trial of transcutaneous electrical posterior tibial nerve stimulation versus lateral internal sphincterotomy for treatment of chronic anal fissure.

    PubMed

    Youssef, Tamer; Youssef, Mohamed; Thabet, Waleed; Lotfy, Ahmed; Shaat, Reham; Abd-Elrazek, Eman; Farid, Mohamed

    2015-10-01

    The objective of this study was to evaluate the efficacy of transcutaneous electrical posterior tibial nerve stimulation in treatment of patients with chronic anal fissure and to compare it with the conventional lateral internal sphincterotomy. Consecutive patients with chronic anal fissure were randomly allocated into two treatment groups: transcutaneous electrical posterior tibial nerve stimulation group and lateral internal sphincterotomy group. The primary outcome measures were number of patients with clinical improvement and healed fissure. Secondary outcome measures were complications, VAS pain scores, Wexner's constipation and Peascatori anal incontinence scores, anorectal manometry, and quality of life index. Seventy-three patients were randomized into two groups of 36 patients who were subjected to transcutaneous electrical nerve stimulation and 37 patients who underwent lateral internal sphincterotomy. All (100%) patients in lateral internal sphincterotomy group had clinical improvement at one month following the procedure in contrast to 27 (75%) patients in transcutaneous electrical nerve stimulation group. Recurrence of anal fissure after one year was reported in one (2.7%) and 11 (40.7%) patients in lateral internal sphincterotomy and transcutaneous electrical nerve stimulation groups respectively. Resting anal pressure and functional anal canal length were significantly reduced after lateral internal sphincterotomy. Transcutaneous electrical posterior tibial nerve stimulation for treatment of chronic anal fissure is a novel, non-invasive procedure and has no complications. However, given the higher rate of clinical improvement and fissure healing and the lower rate of fissure recurrence, lateral internal sphincterotomy remains the gold standard for treating chronic anal fissure. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  20. Sealing performance of a magnetic fluid seal for rotary blood pumps.

    PubMed

    Mitamura, Yoshinori; Takahashi, Sayaka; Kano, Kentaro; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya; Higuchi, Taka-Aki

    2009-09-01

    A magnetic fluid (MF) for a rotary blood pump seal enables mechanical contact-free rotation of the shaft and, hence, has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a "shield" mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Under the condition of continuous flow, the MF seal remained in perfect condition against a pressure of 298 mm Hg (pump flow rate: 3.96 L/min). The seal was also perfect against a pressure of 170 mm Hg in a continuous flow of 3.9 L/min for 275 days. We have developed a MF seal that works in liquid against clinically used pressures. The MF seal is promising as a shaft seal for rotary blood pumps.

  1. The pattern of circumferential and radial eruptive fissures on the volcanoes of Fernandina and Isabela islands, Galapagos

    USGS Publications Warehouse

    Chadwick, W.W.; Howard, K.A.

    1991-01-01

    Maps of the eruptive vents on the active shield volcanoes of Fernandina and Isabela islands, Galapagos, made from aerial photographs, display a distinctive pattern that consists of circumferential eruptive fissures around the summit calderas and radial fissures lower on the flanks. On some volcano flanks either circumferential or radial eruptions have been dominant in recent time. The location of circumferential vents outside the calderas is independent of caldera-related normal faults. The eruptive fissures are the surface expression of dike emplacement, and the dike orientations are interpreted to be controlled by the state of stress in the volcano. Very few subaerial volcanoes display a pattern of fissures similar to that of the Galapagos volcanoes. Some seamounts and shield volcanoes on Mars morphologically resemble the Galapagos volcanoes, but more specific evidence is needed to determine if they also share common structure and eruptive style. ?? 1991 Springer-Verlag.

  2. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    PubMed

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  3. Rotary shaft sealing assembly

    DOEpatents

    Dietle, Lannie L; Schroeder, John E; Kalsi, Manmohan S; Alvarez, Patricio D

    2013-08-13

    A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.

  4. Rotary shaft sealing assembly

    DOEpatents

    Dietle, Lannie L.; Schroeder, John E.; Kalsi, Manmohan S.; Alvarez, Patricio D.

    2010-09-21

    A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.

  5. Can earthquake fissures predispose hillslopes to landslides? - Evidence from Central and East Asia

    NASA Astrophysics Data System (ADS)

    Sidle, Roy C.; Gomi, Takashi; Rajapbaev, Muslim; Chyngozhoev, Nurstan

    2017-04-01

    Factors affecting earthquake-initiated landslides include earthquake magnitude, focal depth, and seismic wave propagation and attenuation. In contrast to rainfall-initiated landslides, earthquake-induced landslides often occur on convex slopes and near ridgelines. Here we present evidence from Fergana Basin, Kyrgyzstan and Kumamoto, Japan on how fissures developed during earthquakes may promote subsequent initiation of rainfall-triggered landslides. More than 1800 recent major landslides in hilly terrain and soft sediments of the Fergana Basin have been largely attributed to accumulation of heavy rainfall and snowmelt. While no large earthquakes have occurred in the Fergana Basin, smaller earthquakes have generated fissures near ridgelines and on convex slopes. The connection of fissures, developed years or decades before slope failure, with preferential transport of rainwater and runoff into the soil has not been previously investigated. Fissures have been observed to expand with time, particularly during subsequent minor earthquakes, further promoting preferential infiltration. Because the soil mantle does not have large contrasts in permeability that would define a slip plane for landslides, it appears that the position and depth of these fissures may control the location and depth of failures. Zones in the soil where surficial inputs of water are preferentially transported, augment natural subsurface accumulation of antecedent rainfall. Many landslides in the eastern Fergana Basin occur after several months of accumulated precipitation and groundwater has been observed emerging on critical hillside locations (near ridgelines and on convex slopes) prior to slope failure. During the 2016 Kumamoto Earthquake (M 7.3), many landslides were triggered in forest and grassland hillslopes near Mount Aso. All of these earthquakes were shallow (focal depths about 10 km), causing high shaking intensity and ground rupturing. Because soils were relatively dry during these

  6. Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents

    PubMed Central

    Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.

    2015-01-01

    Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs <12th grade = 43.3, p = 0.001), gender (male = 27.3 vs female = 19.6, p = 0.04), age (≤15 years = 27.1 vs <15 years = 18.5, p = 0.02), presence of fissure sealants (yes = 30.6 vs no = 13.5, p = 0.001) and experience of dental pain (no = 25.4 vs yes = 16.8, p = 0.02). When analyzing the prevalence of fissure sealants, we verified that 58.8% of adolescents had at least one fissure sealant applied. Significant statistical differences were found when analyzing the presence of fissure sealants related with parents´educational level (<9th grade, OR = 1.56 CI95% = 1.05–2.54), gender (female, OR = 1.86 CI95% = 1.19–2.98), experience of dental pain (yes, OR = 0.62 CI95% = 0.39–0.97) and presence of dental caries (yes, OR = 0.35 CI95% = 0.19–0.65). Conclusions The moderate level of caries prevalence reveals the need of improvement of primary prevention interventions among

  7. Inboard seal mounting

    DOEpatents

    Hayes, John R.

    1983-01-01

    A regenerator assembly for a gas turbine engine has a hot side seal assembly formed in part by a cast metal engine block having a seal recess formed therein that is configured to supportingly receive ceramic support blocks including an inboard face thereon having a regenerator seal face bonded thereto. A pressurized leaf seal is interposed between the ceramic support block and the cast metal engine block to bias the seal wear face into sealing engagement with a hot side surface of a rotary regenerator matrix.

  8. Triple acting radial seal

    DOEpatents

    Ebert, Todd A [West Palm Beach, FL; Carella, John A [Jupiter, FL

    2012-03-13

    A triple acting radial seal used as an interstage seal assembly in a gas turbine engine, where the seal assembly includes an interstage seal support extending from a stationary inner shroud of a vane ring, the interstage seal support includes a larger annular radial inward facing groove in which an outer annular floating seal assembly is secured for radial displacement, and the outer annular floating seal assembly includes a smaller annular radial inward facing groove in which an inner annular floating seal assembly is secured also for radial displacement. A compliant seal is secured to the inner annular floating seal assembly. The outer annular floating seal assembly encapsulates the inner annular floating seal assembly which is made from a very low alpha material in order to reduce thermal stress.

  9. Security seal

    DOEpatents

    Gobeli, Garth W.

    1985-01-01

    Security for a package or verifying seal in plastic material is provided by a print seal with unique thermally produced imprints in the plastic. If tampering is attempted, the material is irreparably damaged and thus detectable. The pattern of the imprints, similar to "fingerprints" are recorded as a positive identification for the seal, and corresponding recordings made to allow comparison. The integrity of the seal is proved by the comparison of imprint identification records made by laser beam projection.

  10. The prevalence of dental caries and fissure sealants in 12 year old children by disadvantaged status in Dublin (Ireland).

    PubMed

    Sagheri, D; McLoughlin, J; Clarkson, J J

    2009-03-01

    The aim was to record dental caries levels and the presence of fissure sealants in 12-year-old schoolchildren whose domestic water supply had been fluoridated since birth in Dublin (Ireland). Cross-sectional study. Participants A representative, random sample of 12-year-old schoolchildren in north-west Dublin. Dental caries levels were recorded using WHO criteria and fissure sealant was recorded when sealant was detectable on a permanent molar tooth. Medical card ownership, as a surrogate for disadvantage, was recorded by use of a questionnaire. Three-hundred and thirty-two (332) children were examined. The mean DMFT was 0.80 (SD 1.24). Analysis (Mann-Whitney U test) based on stratification of the sample according to medical-card status revealed no statistically significant difference between DMFT median scores of children of medical-card holders (i.e., social disadvantage background) and non medical-card holders (p-value = 0.23). However, the data revealed a social gradient in the presence of at least one fissure sealant. Approximately 10% more children in the group of medical-card holders had no fissure sealants present. Fisher's exact test was used to examine the association between the absence of fissure sealants and at least one fissure sealant between the two groups and was considered to be statistically significant (p-value = 0.04). This study demonstrated a social gradient in the presence of fissure sealants, but no such gradient in dental caries levels. This demonstrates the importance of population-based measures in the prevention of dental caries, such as water fluoridation, in reducing oral health inequalities.

  11. The SSME seal test program: Leakage tests for helically-grooved seals

    NASA Technical Reports Server (NTRS)

    Childs, D. W.

    1983-01-01

    Helically grooved annular seal configurations were tested in highly turbulent flow to determine if reduced leakage and enhanced stability would result from the pumping action of the seal. It was found that: (1) leakage of a helically grooved seals decreases with running speed; (2) leakage reduction due to increased running speed is greater at lower values of R sub a; (3) an asymptote for leakage reduction is indicated with increasing running speed; (4) leakage is reduced by reducing the ridge (minimum) and average clearances; (5) leakage increases with increasing pitch angles and with increasing groove depth. Plain seals with smooth rotors and stators will leak more than a helically grooved seal. It was also found that plain seals with a rough rotor and a rough stator leak less than a properly designed helically grooved seal. A properly designed helically grooved seal consumes at least twice as much power as a conventional annular seal.

  12. Sealed-off CO2 laser with In-Au alloy sealing

    NASA Astrophysics Data System (ADS)

    Iehisa, N.; Fukaya, K.; Karube, N.

    1986-02-01

    The In-Au alloy sealing was found to satisfy all the requirements imposed on the sealed-off CO2 lasers. The sealing between different materials such as quartz, SUS 303, Si, and ZnSe was shown to withstand the thermal shock test, and gave the He leak rate lower than 1×10-9 atm cc/s both before and after the tests. It was also proved that the transmittance characteristics of dielectric coated output couplers did not change after the sealing. The sealed-off CO2 lasers with La1-xSrxCoO3 perovskite oxide cathodes sealed with this technique produced the operational life of 3000 h at the laser power level of 50 W/m.

  13. Natural Treatments for Fissure in Ano Used by Traditional Persian Scholars, Razi (Rhazes) and Ibn Sina (Avicenna)

    PubMed Central

    Derakhshan, Ali Reza

    2016-01-01

    Most cases of chronic fissure do not respond to medical treatment. Razi and Ibn Sina were 2 of the best-known scientists of ancient Persia. The purpose of this study was to find out new scientific evidence in modern medicine about their recommendations, in order to find certain clues to conduct useful researches in the future. First, treatments of anal fissure mentioned by Razi and Ibn Sina were reviewed. Then, literature search was made in electronic databases including PubMed, Scopus, and Google Scholar. Management of anal fissure according to Razi’s and Ibn Sina’s practices is done based on 3 interventions: lifestyle modifications, drug treatments, and manual procedures. Almost all remedies suggested by Razi and Ibn Sina have shown their effects on fissure in ano via several mechanisms of action in many in vitro and in vivo studies; Still there is lack of human studies on the subject. PMID:27279645

  14. Natural Treatments for Fissure in Ano Used by Traditional Persian Scholars, Razi (Rhazes) and Ibn Sina (Avicenna).

    PubMed

    Derakhshan, Ali Reza

    2016-06-08

    Most cases of chronic fissure do not respond to medical treatment. Razi and Ibn Sina were 2 of the best-known scientists of ancient Persia. The purpose of this study was to find out new scientific evidence in modern medicine about their recommendations, in order to find certain clues to conduct useful researches in the future. First, treatments of anal fissure mentioned by Razi and Ibn Sina were reviewed. Then, literature search was made in electronic databases including PubMed, Scopus, and Google Scholar. Management of anal fissure according to Razi's and Ibn Sina's practices is done based on 3 interventions: lifestyle modifications, drug treatments, and manual procedures. Almost all remedies suggested by Razi and Ibn Sina have shown their effects on fissure in ano via several mechanisms of action in many in vitro and in vivo studies; Still there is lack of human studies on the subject. © The Author(s) 2016.

  15. Numeric simulation of occlusal interferences in molars restored with ultrathin occlusal veneers.

    PubMed

    Magne, Pascal; Cheung, Raymond

    2017-01-01

    Selecting material for a minimally invasive occlusal veneer reconstruction concept requires an understanding of how stresses are distributed during functional and parafunctional forces. The purpose of this in vitro study was to investigate stress distribution in a maxillary molar restored with ultrathin occlusal veneers and subjected by an antagonistic mandibular molar to clenching and working and nonworking movements. A maxillary first molar was modeled from microcomputed tomography (micro-CT) data, using medical image processing software, stereolithography editing/optimizing software, and finite element software. Simulated ultrathin occlusal veneer materials were used. The mandibular molar antagonist was a solid nondeformable geometric entity. Loads simulated clenching, working, and nonworking movements with loading of 500 N. The values of the maximum principal stress were recorded. In the clenching load situation, maximum tensile stresses were located at the occlusal veneer (52 MPa for composite resin versus 47 MPa for ceramic). In the working movement, significant additional tensile stresses were found on the palatal root (87 MPa for composite resin and 85 MPa for ceramic). In the nonworking movement, tensile stress on the ultrathin occlusal veneer increased to 118 MPa for composite resin and 143 MPa for ceramic veneers. Tensile stress peaks shifted to the mesiobuccal root (75 MPa for composite resin and 74 MPa for ceramic). The topography of stresses generated by the various occlusal interferences were clearly identified. Significant tensile stress concentrations were found within the restoration's occlusal topography and root, with the nonworking interference being the most harmful and also the most revealing of the difference between the composite resin and ceramic ultrathin occlusal veneers. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Seal dynamics on the Swedish west coast: Scenarios of competition as Baltic grey seal intrude on harbour seal territory

    NASA Astrophysics Data System (ADS)

    Svensson, Carl Johan

    2012-07-01

    The Kattegat-Skagerrak region on the Swedish west coast is home to an abundant harbour seal population (Phoca vitulina) and a small scattered grey seal population (Halichoerus grypus). In addition, grey seal from the growing population in the Baltic Sea frequently migrate into the Kattegat-Skagerrak. Harbour seals on the west coast of Sweden show relatively high population growth (approximately 9%) compared to the Baltic grey seal in ice-free habitats (approximately 6%), which, in theory, makes harbour seal the stronger competitor of the two in this region. However, incidents of disease in harbour seals that lower population growth are becoming more frequent. These epidemics are primarily caused by the Phocine Distemper Virus (PDV), and may reduce population size with up to 70%. This study models the average development under potential scenarios of competing harbour- and Baltic grey seal populations using Leslie matrices and the Lotka-Volterra model of inter-specific competition. The model is parameterised with previously published data, and resource overlap is incorporated through density dependent pup survival. Using numerical methods short- and long-term abundances are simulated under weak, moderate and strong competition and for different frequencies of PDV epidemics. Results show that the harbour seals are resilient to competition while exerting a negative effect on grey seal abundance under moderate to strong competition. Hence Baltic grey seal benefit from weaker levels of competition. Under moderate and strong competition grey seal abundance is a direct function of the PDV frequency as this reduces the competitive strength of harbour seals. Theoretically this means that higher frequencies of PDV or other pathogens epidemics could facilitate an expansion of Baltic grey seal into Kattegat-Skagerrak. Independent of interaction strength and frequency of epidemics the projected changes to abundances are slow (50-100 years), and even in exceedingly stable

  17. Skew resisting hydrodynamic seal

    DOEpatents

    Conroy, William T.; Dietle, Lannie L.; Gobeli, Jeffrey D.; Kalsi, Manmohan S.

    2001-01-01

    A novel hydrodynamically lubricated compression type rotary seal that is suitable for lubricant retention and environmental exclusion. Particularly, the seal geometry ensures constraint of a hydrodynamic seal in a manner preventing skew-induced wear and provides adequate room within the seal gland to accommodate thermal expansion. The seal accommodates large as-manufactured variations in the coefficient of thermal expansion of the sealing material, provides a relatively stiff integral spring effect to minimize pressure-induced shuttling of the seal within the gland, and also maintains interfacial contact pressure within the dynamic sealing interface in an optimum range for efficient hydrodynamic lubrication and environment exclusion. The seal geometry also provides for complete support about the circumference of the seal to receive environmental pressure, as compared the interrupted character of seal support set forth in U.S. Pat. Nos. 5,873,576 and 6,036,192 and provides a hydrodynamic seal which is suitable for use with non-Newtonian lubricants.

  18. Brucella Antibodies in Alaskan True Seals and Eared Seals-Two Different Stories.

    PubMed

    Nymo, Ingebjørg H; Rødven, Rolf; Beckmen, Kimberlee; Larsen, Anett K; Tryland, Morten; Quakenbush, Lori; Godfroid, Jacques

    2018-01-01

    Brucella pinnipedialis was first isolated from true seals in 1994 and from eared seals in 2008. Although few pathological findings have been associated with infection in true seals, reproductive pathology including abortions, and the isolation of the zoonotic strain type 27 have been documented in eared seals. In this study, a Brucella enzyme-linked immunosorbent assay (ELISA) and the Rose Bengal test (RBT) were initially compared for 206 serum samples and a discrepancy between the tests was found. Following removal of lipids from the serum samples, ELISA results were unaltered while the agreement between the tests was improved, indicating that serum lipids affected the initial RBT outcome. For the remaining screening, we used ELISA to investigate the presence of Brucella antibodies in sera of 231 eared and 1,412 true seals from Alaskan waters sampled between 1975 and 2011. In eared seals, Brucella antibodies were found in two Steller sea lions ( Eumetopias jubatus ) (2%) and none of the 107 Northern fur seals ( Callorhinus ursinus ). The low seroprevalence in eared seals indicate a low level of exposure or lack of susceptibility to infection. Alternatively, mortality due to the Brucella infection may remove seropositive animals from the population. Brucella antibodies were detected in all true seal species investigated; harbor seals ( Phoca vitulina ) (25%), spotted seals ( Phoca largha ) (19%), ribbon seals ( Histriophoca fasciata ) (16%), and ringed seals ( Pusa hispida hispida ) (14%). There was a low seroprevalence among pups, a higher seroprevalence among juveniles, and a subsequent decreasing probability of seropositivity with age in harbor seals. Similar patterns were present for the other true seal species; however, solid conclusions could not be made due to sample size. This pattern is in accordance with previous reports on B. pinnipedialis infections in true seals and may suggest environmental exposure to B. pinnipedialis at the juvenile stage, with a

  19. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference.

    PubMed

    Ono, Yumie; Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-11-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near-infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task-related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task-related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD.

  20. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference

    PubMed Central

    Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-01-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near‐infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task‐related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task‐related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD. PMID:29744159

  1. Corkscrew Seals: Grey Seal (Halichoerus grypus) Infanticide and Cannibalism May Indicate the Cause of Spiral Lacerations in Seals

    PubMed Central

    2016-01-01

    Large numbers of dead seals with characteristic spiral lesions have been washing ashore around the North Atlantic over the past two decades. Interactions with ship propellers and shark predation have been suggested as the likely causal mechanisms. However, new evidence points towards a more likely candidate: grey seal predation. An adult male grey seal was observed and recorded catching, killing and eating five weaned grey seal pups over a period of one week on the Isle of May, Scotland. A further 9 carcasses found in the same area exhibited similar injuries. Post mortem analysis of lesions indicated the wound characteristics were similar to each other and in 12 of the 14 carcasses analysed, were indistinguishable from carcasses previously attributed to propeller interaction. We therefore propose that most of the seal carcasses displaying spiral lacerations in the UK are caused by grey seal predation. Cases in other locations should be re-evaluated using the scoring system presented here to identify whether grey seal predation is a major cause of mortality in phocid seals. PMID:27254025

  2. Corkscrew Seals: Grey Seal (Halichoerus grypus) Infanticide and Cannibalism May Indicate the Cause of Spiral Lacerations in Seals.

    PubMed

    Brownlow, Andrew; Onoufriou, Joseph; Bishop, Amanda; Davison, Nicholas; Thompson, Dave

    2016-01-01

    Large numbers of dead seals with characteristic spiral lesions have been washing ashore around the North Atlantic over the past two decades. Interactions with ship propellers and shark predation have been suggested as the likely causal mechanisms. However, new evidence points towards a more likely candidate: grey seal predation. An adult male grey seal was observed and recorded catching, killing and eating five weaned grey seal pups over a period of one week on the Isle of May, Scotland. A further 9 carcasses found in the same area exhibited similar injuries. Post mortem analysis of lesions indicated the wound characteristics were similar to each other and in 12 of the 14 carcasses analysed, were indistinguishable from carcasses previously attributed to propeller interaction. We therefore propose that most of the seal carcasses displaying spiral lacerations in the UK are caused by grey seal predation. Cases in other locations should be re-evaluated using the scoring system presented here to identify whether grey seal predation is a major cause of mortality in phocid seals.

  3. Fundamentals of fluid sealing

    NASA Technical Reports Server (NTRS)

    Zuk, J.

    1976-01-01

    The fundamentals of fluid sealing, including seal operating regimes, are discussed and the general fluid-flow equations for fluid sealing are developed. Seal performance parameters such as leakage and power loss are presented. Included in the discussion are the effects of geometry, surface deformations, rotation, and both laminar and turbulent flows. The concept of pressure balancing is presented, as are differences between liquid and gas sealing. Mechanisms of seal surface separation, fundamental friction and wear concepts applicable to seals, seal materials, and pressure-velocity (PV) criteria are discussed.

  4. Femtosecond Laser in situ Keratomileusis Flap Creation in Narrow Palpebral Fissure Eyes without Suction.

    PubMed

    Chang, John S M; Law, Antony K P; Ng, Jack C M; Cheng, May S Y

    2017-01-01

    To evaluate a surgical technique used in eyes with narrow palpebral fissure undergoing femtosecond laser flap creation without suction during laser in situ keratomileusis (LASIK). All data of 2 patient groups were collected through chart review. Group 1 consisted of 6 eyes with narrow palpebral fissure in which the suction ring was manually fixated and femtosecond laser was applied accordingly. Thirty comparison cases were randomly drawn from among eyes that underwent a standard LASIK procedure matched for age and preoperative refraction (group 2). Only 1 eye of each patient was selected to compare the refractive and visual outcomes between groups. In all group 1 eyes, the flaps were created successfully with manual fixation of the suction ring without suction. No eyes lost 2 or more lines of vision. No significant difference was found in the safety and refractive outcomes between groups. Manual fixation of the suction ring in eyes with narrow palpebral fissure without suction was feasible for flap creation during LASIK.

  5. Seroprevalence of Antibodies against Seal Influenza A(H10N7) Virus in Harbor Seals and Gray Seals from the Netherlands.

    PubMed

    Bodewes, Rogier; Rubio García, Ana; Brasseur, Sophie M; Sanchez Conteras, Guillermo J; van de Bildt, Marco W G; Koopmans, Marion P G; Osterhaus, Albert D M E; Kuiken, Thijs

    2015-01-01

    In the spring and summer 2014, an outbreak of seal influenza A(H10N7) virus infection occurred among harbor seals (Phoca vitulina) off the coasts of Sweden and Denmark. This virus subsequently spread to harbor seals off the coasts of Germany and the Netherlands. While thousands of seals were reported dead in Sweden, Denmark and Germany, only a limited number of seals were found dead in the Netherlands. To determine the extent of exposure of seals in the Netherlands to influenza A/H10N7 virus, we measured specific antibody titers in serum samples from live-captured seals and seals admitted for rehabilitation in the Netherlands by use of a hemagglutination inhibition assay and an ELISA. In harbor seals in 2015, antibodies against seal influenza A(H10N7) virus were detected in 41% (32 out of 78) pups, 10% (5 out of 52) weaners, and 58% (7 out of 12) subadults or adults. In gray seals (Halichoerus grypus) in 2015, specific antibodies were not found in the pups (n = 26), but in 26% (5 out of 19) of the older animals. These findings indicate that, despite apparent low mortality, infection with seal influenza A(H10N7) virus was geographically widespread and also occurred in grey seals.

  6. Indium sealing techniques.

    NASA Technical Reports Server (NTRS)

    Hochuli, U.; Haldemann, P.

    1972-01-01

    Gold films are used as an alloying flux to form 5-micron-thick indium film seals at temperatures below 300 C. Pyrex was sealed to quartz, ULE, CER-VIT, Irtran 2, Ge, GaAs, Invar, Kovar, Al, and Cu. The seals can also be used as current feedthroughs and graded seals.

  7. Shaft seal system

    DOEpatents

    Kapich, Davorin D.

    1985-01-01

    A shaft seal system is disclosed for isolating two regions of different fluid mediums through which a rotatable shaft extends. The seal system includes a seal housing through which the shaft extends and which defines an annular land and an annular labyrinth both of which face on the shaft so that each establishes a corresponding fluid sealing annulus. A collection cavity is formed in communication with the annular sealing spaces, and fluids compatible with the fluids in each of the two regions to be isolated are introduced, respectively, into the annular sealing spaces and collected in the collection cavity from which the fluid mixture is removed and passed to a separator which separates the fluids and returns them to their respective annular sealing spaces in a recycling manner. In the illustrated embodiment, the isolated fluid mediums comprise a liquid region and a gas region. Gas is removed from the gas region and passed through a purifier and a gas pump operative to introduce the purified gas through the labyrinth sealing annulus to the collection cavity. After passing to the separator, the separated gas is passed through a dryer from which the dried gas is caused to pass through the labyrinth sealing annulus into the collection cavity independently of the purified gas so as to insure isolation of the gas region in the event of sealing gas pump malfunction.

  8. X-38 Seal Development

    NASA Technical Reports Server (NTRS)

    Curry, Donald M.; Lewis, Ronald K.; Hagen, Jeffrey D.

    2002-01-01

    An X-38 Crew Return Vehicle Seal Development is presented. The contents include: 1) X-38 Crew Return Vehicle; 2) X-38 TPS Configuration; 3) X-38 Seal Locations; 4) X-38 Rudder/Fin Seal Assembly; 5) Baseline X-38 Rudder/Fin Seal Design; 6) Rudder/Fin Seal to Bracket Assembly; 7) X-38 Rudder/Fin Vertical Rub Surface Inconel-0.10 inches; 8) X-38 Rudder/Fin Seal Analysis; 9) Seal Analysis Model; and 10) Governing Differential Equations for Equilibrium Thermal Assumption. The X-38 Rudder/Fin Seal temperature and pressure properties are also given.

  9. Dynamic sealing principles

    NASA Technical Reports Server (NTRS)

    Zuk, J.

    1976-01-01

    The fundamental principles governing dynamic sealing operation are discussed. Different seals are described in terms of these principles. Despite the large variety of detailed construction, there appear to be some basic principles, or combinations of basic principles, by which all seals function, these are presented and discussed. Theoretical and practical considerations in the application of these principles are discussed. Advantages, disadvantages, limitations, and application examples of various conventional and special seals are presented. Fundamental equations governing liquid and gas flows in thin film seals, which enable leakage calculations to be made, are also presented. Concept of flow functions, application of Reynolds lubrication equation, and nonlubrication equation flow, friction and wear; and seal lubrication regimes are explained.

  10. Deformation at longyao ground fissure and its surroundings, north China plain, revealed by ALOS PALSAR PS-InSAR

    NASA Astrophysics Data System (ADS)

    Yang, Chengsheng; Lu, Zhong; Zhang, Qin; Zhao, Chaoying; Peng, Jianbing; Ji, Lingyun

    2018-05-01

    The Longyao ground fissure (LGF) is the longest and most active among more than 1000 ground fissures on the North China Plain. There have been many studies on the formation mechanism of the LGF, due to its scientific importance and its potential for damage to the environment. These studies have been based on both regional tectonic analysis and numerical simulations. In order to provide a better understanding of the formation mechanism, the deformation of the crack and its surrounding environment should be taken into consideration. In this paper, PS-InSAR technology was employed to assess the ground deformation of LGF and its surrounding area, using L-band ALOS-1 PALSAR images from 2007 to 2011. The characteristics of ground deformation, relationships between fissure activity and surrounding faults and groundwater exploitation were analyzed. This study shows that the north side of Longyao fault (LF) is uplifting while the south side is subsiding. This provides the tectonic conditions responsible for the activity of the ground fissure. Local groundwater exploitation also plays an important role in the development of ground fissures. InSAR observations were modeled to infer the loading depth (-2.8 km) and the slip rate (31.1 mm/yr) of LF.

  11. Dental Pit and Fissure Sealants: Implications for School Health Personnel.

    ERIC Educational Resources Information Center

    McCormack-Brown, K. R.; And Others

    1989-01-01

    To promote good personal hygiene practices in students, school health personnel must be informed about dental pit and fissure sealants and related programs. Adoption and maintenance of such programs may depend on the success of school health personnel in educating administrators and policymakers. (SM)

  12. Turbine blade platform seal

    DOEpatents

    Zagar, Thomas W.; Schiavo, Anthony L.

    2001-01-01

    A rotating blade group 90 for a turbo-machine having an improved device for sealing the gap 110 between the edges 112,114 of adjacent blade platforms 96,104. The gap 110 between adjacent blades 92,100 is sealed by a seal pin 20 its central portion 110 and by a seal plate 58,60 at each of the front 54 and rear 56 portions. The seal plates 58,60 are inserted into corresponding grooves 62,64 formed in the adjacent edges 112,114 of adjoining blades 92,100 and held in place by end plates 40,42. The end of the seal plates 58,60 may be chamfered 78,80 to improve the seal against the end plate 40,42. The seal pin 20 provides the required damping between the blades 92,100 and the seal plates 58,60 provide improved sealing effectiveness.

  13. Fuel cell manifold sealing system

    DOEpatents

    Grevstad, Paul E.; Johnson, Carl K.; Mientek, Anthony P.

    1980-01-01

    A manifold-to-stack seal and sealing method for fuel cell stacks. This seal system solves the problem of maintaining a low leak rate manifold seal as the fuel cell stack undergoes compressive creep. The seal system eliminates the problem of the manifold-to-stack seal sliding against the rough stack surface as the stack becomes shorter because of cell creep, which relative motion destroys the seal. The seal system described herein utilizes a polymer seal frame firmly clamped between the manifold and the stack such that the seal frame moves with the stack. Thus, as the stack creeps, the seal frame creeps with it, and there is no sliding at the rough, tough to seal, stack-to-seal frame interface. Here the sliding is on a smooth easy to seal location between the seal frame and the manifold.

  14. Three-Dimensional Numerical Simulation on Triaxial Failure Mechanical Behavior of Rock-Like Specimen Containing Two Unparallel Fissures

    NASA Astrophysics Data System (ADS)

    Huang, Yan-Hua; Yang, Sheng-Qi; Zhao, Jian

    2016-12-01

    A three-dimensional particle flow code (PFC3D) was used for a systematic numerical simulation of the strength failure and cracking behavior of rock-like material specimens containing two unparallel fissures under conventional triaxial compression. The micro-parameters of the parallel bond model were first calibrated using the laboratory results of intact specimens and then validated from the experimental results of pre-fissured specimens under triaxial compression. Numerically simulated stress-strain curves, strength and deformation parameters and macro-failure modes of pre-fissured specimens were all in good agreement with the experimental results. The relationship between stress and the micro-crack numbers was summarized. Crack initiation, propagation and coalescence process of pre-fissured specimens were analyzed in detail. Finally, horizontal and vertical cross sections of numerical specimens were derived from PFC3D. A detailed analysis to reveal the internal damage behavior of rock under triaxial compression was carried out. The experimental and simulated results are expected to improve the understanding of the strength failure and cracking behavior of fractured rock under triaxial compression.

  15. Turbine with radial acting seal

    DOEpatents

    Eng, Darryl S; Ebert, Todd A

    2016-11-22

    A floating brush seal in a rim cavity of a turbine in a gas turbine engine, where the floating brush seal includes a seal holder in which the floating brush seal floats, and a expandable seal that fits within two radial extending seal slots that maintains a seal with radial displacement of the floating brush seal and the seal holder.

  16. Tamper-indicating seal

    DOEpatents

    Fiarman, S.; Degen, M.F.; Peters, H.F.

    1982-08-13

    There is disclosed a tamper-indicating seal that permits in the field inspection and detection of tampering. Said seal comprises a shrinkable tube having a visible pattern of markings which is shrunk over th item to be sealed, and a second transparent tube, having a second visible marking pattern, which is shrunk over the item and the first tube. The relationship between the first and second set of markings produces a pattern so that the seal may not be removed without detection. The seal is particularly applicable to UF/sub 6/ cylinder valves.

  17. Medical and surgical treatment of haemorrhoids and anal fissure in Crohn’s disease: a critical appraisal

    PubMed Central

    2013-01-01

    Background The principle to avoid surgery for haemorrhoids and/or anal fissure in Crohn’s disease (CD) patients is still currently valid despite advances in medical and surgical treatments. In this study we report our prospectively recorded data on medical and surgical treatment of haemorrhoids and anal fissures in CD patients over a period of 8 years. Methods Clinical data of patients affected by perianal disease were routinely and prospectively inserted in a database between October 2003 and October 2011 at the Department of Surgery, Tor Vergata University Hospital, Rome. We reviewed and divided in two groups records on CD patients treated either medically or surgically according to the diagnosis of haemorrhoids or anal fissures. Moreover, we compared in each group the outcome in patients with prior diagnosis of CD and in patients diagnosed with CD only after perianal main treatment. Results Eighty-six CD patients were included in the study; 45 were treated for haemorrhoids and 41 presented with anal fissure. Conservative approach was initially adopted for all patients; in case of medical treatment failure, the presence of stable intestinal disease made them eligible for surgery. Fifteen patients underwent haemorrhoidectomy (open 11; closed 3; stapled 1), and two rubber band ligation. Fourteen patients required surgery for anal fissure (Botox ± fissurectomy 8; LIS 6). In both groups we observed high complication rate, 41.2% for haemorrhoids and 57.1% for anal fissure. Patients who underwent haemorrhoidectomy without certain diagnosis of CD had significantly higher risk of complications. Conclusions Conservative treatment of proctologic diseases in CD patients has been advocated given the high risk of complications and the evidence that spontaneous healing may also occur. From these preliminary results a role of surgery is conceivable in high selected patients, but definitve conclusions can’t be made. Further randomized trials are needed to establish the

  18. King's Bowl Pit Crater, Lava Field and Eruptive Fissure, Idaho - A Multipurpose Volcanic Planetary Analog

    NASA Astrophysics Data System (ADS)

    Hughes, S. S.; Garry, B.; Kobs-Nawotniak, S. E.; Sears, D. W. G.; Borg, C.; Elphic, R. C.; Haberle, C. W.; Kobayashi, L.; Lim, D. S. S.; Sears, H.; Skok, J. R.; Heldmann, J. L.

    2014-12-01

    King's Bowl (KB) and its associated eruptive fissure and lava field on the eastern Snake River Plain, is being investigated by the NASA SSERVI FINESSE (Field Investigations to Enable Solar System Science and Exploration) team as a planetary analog to similar pits on the Moon, Mars and Vesta. The 2,220 ± 100 BP basaltic eruption in Craters of the Moon National Monument and Preserve represents early stages of low shield growth, which was aborted when magma supply was cut off. Compared to mature shields, KB is miniscule, with ~0.02 km3 of lava over ~3 km2, yet the ~6 km long series of fissures, cracks and pits are well-preserved for analog studies of volcanic processes. The termination of eruption was likely related to proximity of the 2,270 ± 50 BP eruption of the much larger Wapi lava field (~5.5 km3 over 325 km2 area) on the same rift. Our investigation extends early work by R. Greeley and colleagues, focusing on imagery, compositional variations, ejecta distribution, dGPS profiles and LiDAR scans of features related to: (1) fissure eruptions - spatter ramparts, cones, feeder dikes, extension cracks; (2) lava lake formation - surface morphology, squeeze-ups, slab pahoehoe lava mounds, lava drain-back, flow lobe overlaps; and (3) phreatic steam blasts - explosion pits, ejecta blankets of ash and blocks. Preliminary results indicate multiple fissure eruptions and growth of a basin-filled lava lake up to ~ 10 m thick with outflow sheet lava flows. Remnant mounds of original lake crust reveal an early high lava lake level, which subsided as much as 5 m as the molten interior drained back into the fissure system. Rapid loss of magma supply led to the collapse of fissure walls allowing groundwater influx that triggered multiple steam blasts along at least 500 m. Early blasts occurred while lake magma pressure was still high enough to produce squeeze-ups when penetrated by ejecta blocks. The King's Bowl pit crater exemplifies processes of a small, but highly energetic

  19. Nozzle seal

    DOEpatents

    Herman, Richard Frederick

    1977-10-25

    In an illustrative embodiment of the invention, a nuclear reactor pressure vessel, having an internal hoop from which the heated coolant emerges from the reactor core and passes through to the reactor outlet nozzles, is provided with sealing members operatively disposed between the outlet nozzle and the hoop. The sealing members are biased against the pressure vessel and the hoop and are connected by a leak restraining member establishing a leak-proof condition between the inlet and outlet coolants in the region about the outlet nozzle. Furthermore, the flexible responsiveness of the seal assures that the seal will not structurally couple the hoop to the pressure vessel.

  20. Novel QTLs affecting rice kernel fissure resistance discovered in the cultivar ‘Saber’ augment those from ‘Cybonnet’

    USDA-ARS?s Scientific Manuscript database

    Kernel fissures in rice (Oryza sativa L.) caused by pre- or post-harvest stresses are the leading cause of breakage among milled rice. Such breakage causes economic losses for producers, millers, and marketers. Five QTLs for kernel fissure resistance (FR) were identified among a set of 275 RILs de...

  1. Nuclear reactor sealing system

    DOEpatents

    McEdwards, James A.

    1983-01-01

    A liquid metal-cooled nuclear reactor sealing system. The nuclear reactor includes a vessel sealed at its upper end by a closure head. The closure head comprises at least two components, one of which is rotatable; and the two components define an annulus therebetween. The sealing system includes at least a first and second inflatable seal disposed in series in an upper portion of the annulus. The system further includes a dip seal extending into a body of insulation located adjacent a bottom portion of the closure head. The dip seal comprises a trough formed by a lower portion of one of the components, and a seal blade pendently supported from the other component and extending downwardly into the trough. A body of liquid metal is contained in the trough which submerges a portion of the seal blade. The seal blade is provided with at least one aperture located above the body of liquid metal for providing fluid communication between the annulus intermediate the dip seal and the inflatable seals, and a body of cover gas located inside the vessel. There also is provided means for introducing a purge gas into the annulus intermediate the inflatable seals and the seal blade. The purge gas is introduced in an amount sufficient to substantially reduce diffusion of radioactive cover gas or sodium vapor up to the inflatable seals. The purge gas mixes with the cover gas in the reactor vessel where it can be withdrawn from the vessel for treatment and recycle to the vessel.

  2. Seismic and Infrasound Recordings from Kilauea Volcano: Volcanic Tremor, Lava Outbreaks, and Fissure Eruptions

    NASA Astrophysics Data System (ADS)

    Fee, D.; Garces, M.; Orr, T.

    2007-12-01

    The continuous effusion from the Pu'u 'O'o crater complex, the active vent of Kilauea Volcano, Hawaii, produced nearly continuous tremor for years. Recently this tremor was recorded by two infrasound arrays, one at 12.5 km and one at 2.5 km, as well as a broadband seismometer at the closer array. These recordings exhibit significant temporal changes. A sharp, complex spectral peak of ~0.6 Hz is present in nearly the entire dataset, and tends to bifurcate and shift frequency over time. Although the seismic wavefield at Kilauea is complex and path effects appear to play a significant role, this spectral peak is also weakly manifested in the seismic recordings. Array processing of the infrasonic data reveals an abundance of broadband signal as well. Most of the signal appears to originate from the main crater region. However, the 2.5 km array detected the presence of a skylight with growing hornitos ~400 m south of Pu'u 'O'o on the active lava tube system. On June 19th, 2007, the magmatic system at Pu'u 'O'o changed. An intrusion of magma reached the surface 6 km west of the crater complex. The timing and location of the lava outbreak were determined acoustically using array processing. Two distinct acoustic pulses were recorded from the correct azimuth, both exhibiting harmonics. The 7/21 fissure eruption also produced clear infrasound signals. The onset of the fissure eruption east of P'u' 'O'o was apparent beginning around midnight on 7/21 and was focused between ~1.5-5 Hz. Although the fissure eruption continued to produce infrasound, the character of the recorded signal changes over time. A third infrasound array was placed closer to P'u' 'O'o and the fissure to help further constrain the eruption. More detailed results on acoustic signals from the Father's Day Intrusion and Fissure eruption will be presented.

  3. Compliant seal development

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.

    1993-01-01

    The compliant metallic seal combines the noncontact feature of the labyrinth seal, the low leakage of a mechanical seal, and the compliant nature of the brush seal. It consists of several thin metallic elements or leaves mounted within a ring which is press fit into the housing, and in form, sort of resembles a lip seal sections wiping the shaft. A second set of overlapping cover leaves are placed on top of the shaft riding leaves which reduces leakage and provides stiffness. The leaves can be straight or angle cut. The shaft riding fingers are designed with mismatched curvature to provide lift off similar to the Rayleigh lift pads in mechanical seals with leading edge clearances nearly twice those of the trailing edge as as shown by Fleming to be optimal for gas flows in convergent seal passages. Leading edge clearances range from 300 to 500 microinches. Balance pockets beneath the leaves provide fluid film feed to the 'Rayleigh lift' surface and the proper balance ratio (mechanical seal) when combined with the static pressure and film pressure. The leaves flex in the radial direction and accommodate thermomechanical behavior as well as axial motion and angular misalignment. In the static mode, there is a net closing force on the leaves. The seals were tested to 70 psi at speeds to 16,000 rpm or surface speeds to 330 fps and temperatures from ambient to 440 F. A slow cycle through the rig critical at 10,000 rpm induced a radial vibration response of 0.004 to 0.005 inch were accommodated by the seal. Preliminary performance data are encouraging demonstrating hydrodynamic liftoff and noncontacting operation at pressure and speeds typical of gas turbine engines. The leakage performance data are significantly better than commercial labyrinth and brush seals which should be expected as this design incorporates the features of the low leakage face or mechanical seal along with the flexibility of the brush configuration.

  4. Compliant seal development

    NASA Astrophysics Data System (ADS)

    Hendricks, Robert C.

    1993-10-01

    The compliant metallic seal combines the noncontact feature of the labyrinth seal, the low leakage of a mechanical seal, and the compliant nature of the brush seal. It consists of several thin metallic elements or leaves mounted within a ring which is press fit into the housing, and in form, sort of resembles a lip seal sections wiping the shaft. A second set of overlapping cover leaves are placed on top of the shaft riding leaves which reduces leakage and provides stiffness. The leaves can be straight or angle cut. The shaft riding fingers are designed with mismatched curvature to provide lift off similar to the Rayleigh lift pads in mechanical seals with leading edge clearances nearly twice those of the trailing edge as as shown by Fleming to be optimal for gas flows in convergent seal passages. Leading edge clearances range from 300 to 500 microinches. Balance pockets beneath the leaves provide fluid film feed to the 'Rayleigh lift' surface and the proper balance ratio (mechanical seal) when combined with the static pressure and film pressure. The leaves flex in the radial direction and accommodate thermomechanical behavior as well as axial motion and angular misalignment. In the static mode, there is a net closing force on the leaves. The seals were tested to 70 psi at speeds to 16,000 rpm or surface speeds to 330 fps and temperatures from ambient to 440 F. A slow cycle through the rig critical at 10,000 rpm induced a radial vibration response of 0.004 to 0.005 inch were accommodated by the seal. Preliminary performance data are encouraging demonstrating hydrodynamic liftoff and noncontacting operation at pressure and speeds typical of gas turbine engines. The leakage performance data are significantly better than commercial labyrinth and brush seals which should be expected as this design incorporates the features of the low leakage face or mechanical seal along with the flexibility of the brush configuration.

  5. Self-acting shaft seals

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P.

    1978-01-01

    Self-acting seals are described in detail. The mathematical models for obtaining a seal force balance and the equilibrium operating film thickness are outlined. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis reveals three different vibration models with secondary seal friction being an important parameter. Leakage flow inlet pressure drop and affects of axisymmetric sealing face deformations are discussed. Experimental data on self-acting face seals operating under simulated gas turbine conditions are given. Also a spiral groove seal design operated to 244 m/sec (800 ft/sec) is described.

  6. Damped flexible seal

    DOEpatents

    DuBois, Neil J.; Amaral, Antonio M.

    1992-10-27

    A damped flexible seal assembly for a torpedo isolates the tailcone thereof rom vibrational energy present in the drive shaft assembly. A pair of outside flanges, each of which include an inwardly facing groove and an O-ring constrained therein, provide a watertight seal against the outer non-rotating surface of the drive shaft assembly. An inside flange includes an outwardly-facing groove and an O-ring constrained therein, and provides a watertight seal against the inner surface of the tail cone. Two cast-in-place elastomeric seals provide a watertight seal between the flanges and further provide a damping barrier between the outside flanges and the inside flanges for damping vibrational energy present in the drive shaft assembly before the energy can reach the tailcone through the seal assembly.

  7. Compliant Turbomachine Sealing

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Braun, M. J.; Deng, D.; Hendricks, J. A.

    2011-01-01

    Sealing interface materials and coatings are sacrificial, giving up their integrity for the benefit of the component. Seals that are compliant while still controlling leakage, dynamics, and coolant flows are sought to enhance turbomachine performance. Herein we investigate the leaf-seal configuration. While the leaf seal is classified as contacting, a ready modification using the leaf-housing arrangement in conjunction with an interface film rider (a bore seal, for example) provides for a film-riding noncontact seal. The leaf housing and leaf elements can be made from a variety of materials from plastic to ceramic. Four simplistic models are used to identify the physics essential to controlling leakage. Corroborated by CFD, these results provide design parameters for applications to within reasonable engineering certainty. Some potential improvements are proposed.

  8. Contralateral Occlusion Test: The effect of external ear canal occlusion on hearing thresholds.

    PubMed

    Reis, Luis Roque; Fernandes, Paulo; Escada, Pedro

    Bedside testing with tuning forks may decrease turnaround time and improve decision making for a quick qualitative assessment of hearing loss. The purpose of this study was to quantify the effects of ear canal occlusion on hearing, in order to decide which tuning fork frequency is more appropriate to use for quantifying hearing loss with the Contralateral Occlusion Test. Twenty normal-hearing adults (forty ears) underwent sound field pure tone audiometry with and without ear canal occlusion. Each ear was tested with the standard frequencies. The contralateral ear was suppressed with by masking. Ear occlusion was performed by two examiners. Participants aged between 21 and 30 years (25.6±3.03 years) showed an increase in hearing thresholds with increasing frequencies from 19.94dB (250Hz) to 39.25dB (2000Hz). The threshold difference between occluded and unoccluded conditions was statistically significant and increased from 10.69dB (250Hz) to 32.12dB (2000Hz). There were no statistically significant differences according to gender or between the examiners. The occlusion effect increased the hearing thresholds and became more evident with higher frequencies. The occlusion method as performed demonstrated reproducibility. In the Contralateral Occlusion Test, 256Hz or 512Hz tuning forks should be used for diagnosis of mild hearing loss, and a 2048Hz tuning fork should be used for moderate hearing loss. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  9. Pathological investigation of caries and occlusal pulpar exposure in donkey cheek teeth using computerised axial tomography with histological and ultrastructural examinations.

    PubMed

    Toit, Nicole du; Burden, Faith A; Kempson, Sue A; Dixon, Padraic M

    2008-12-01

    Post-mortem examination of 16 donkey cheek teeth (CT) with caries (both peripheral and infundibular) and pulpar exposure were performed using computerised axial tomography (CAT), histology and scanning electron microscopy. CAT imaging was found to be useful to assess the presence and extent of caries and pulp exposure in individual donkey CT. Histology identified the loss of occlusal secondary dentine, and showed pulp necrosis in teeth with pulpar exposure. Viable pulp was present more apically in one exposed pulp horn, with its occlusal aspect sealed off from the exposed aspect of the pulp horn by a false pulp stone. Scanning electron microscopy showed the amelo-cemental junction to be a possible route of bacterial infection in infundibular cemental caries. The basic pathogenesis of dental caries in donkeys appears very similar to its description in other species.

  10. Femtosecond Laser in situ Keratomileusis Flap Creation in Narrow Palpebral Fissure Eyes without Suction

    PubMed Central

    Chang, John S.M.; Law, Antony K.P.; Ng, Jack C.M.; Cheng, May S.Y.

    2017-01-01

    Purpose To evaluate a surgical technique used in eyes with narrow palpebral fissure undergoing femtosecond laser flap creation without suction during laser in situ keratomileusis (LASIK). Methods All data of 2 patient groups were collected through chart review. Group 1 consisted of 6 eyes with narrow palpebral fissure in which the suction ring was manually fixated and femtosecond laser was applied accordingly. Thirty comparison cases were randomly drawn from among eyes that underwent a standard LASIK procedure matched for age and preoperative refraction (group 2). Only 1 eye of each patient was selected to compare the refractive and visual outcomes between groups. Results In all group 1 eyes, the flaps were created successfully with manual fixation of the suction ring without suction. No eyes lost 2 or more lines of vision. No significant difference was found in the safety and refractive outcomes between groups. Conclusion Manual fixation of the suction ring in eyes with narrow palpebral fissure without suction was feasible for flap creation during LASIK. PMID:28690535

  11. Numerical Investigation of the Effect of Radial Lip Seal Geometry on Sealing Performance

    NASA Astrophysics Data System (ADS)

    Tok, G.; Parlar, Z.; Temiz, V.

    2018-01-01

    Sealing elements are often needed in industry and especially in machine design. With the change and development of machine technology from day to day, sealing elements show continuous development and change in parallel with these developments. Many factors influence the performance of the sealing elements such as shaft surface roughness, radial force, lip geometry etc. In addition, the radial lip seals must have a certain pre-load and interference in order to provide a good sealing. This also affects the friction torque. Researchers are developing new seal designs to reduce friction losses in mechanical systems. In the presented study, the effect of the lip seal geometry on sealing performance will be examined numerically. The numerical model created for this purpose will be verified with experimental data firstly. In the numerical model, shaft and seal will be modeled as hyper-elastic in 2D and 3D. NBR (Nitrile Butadiene Rubber) as seal material will be analyzed for the rotating shaft state at constant speed by applying a uniform radial force.

  12. COMPRESSION SEAL AND SEALING MATERIAL THEREFOR

    DOEpatents

    Branin, T.G.

    1962-05-29

    This patent relates to compression seal and more particularly to a seaiing material therefor. The sealing surface is a coating consisting of alternate layers of gold and of a non-gold metal having similar plastic flow properties under pressure as gold. The coating is substantially free from oxidation effects when exposed to ambient atmosphere and does not become brittle when worked, as in a valve. (AEC)

  13. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    PubMed

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  14. Anal self-massage in the treatment of acute anal fissure: a randomized prospective study.

    PubMed

    Gaj, Fabio; Biviano, Ivano; Candeloro, Laura; Andreuccetti, Jacopo

    2017-01-01

    An anal fissure (AF) is a tear in the epithelial lining of the anal canal. This is a very common condition, but the choice of treatment is unclear. The use of anal dilators is effective, economic, and safe. The aim of the study was to compare the efficacy of two conservative treatments, the use of anal dilators or a finger for anal dilatation, in reducing anal pressure and resolving anal fissures. Fifty patients with a clinical diagnosis of AF were randomly assigned to one of the treatments, self-massage of the anal sphincter (group A, 25 patients) or passive dilatation using dilators (group B, 25 patients). All patients were evaluated at baseline, at the end of treatment, and after 12 weeks and 6 months. Pain was measured using a visual analog scale. After the treatment, 60% of patients treated with dilators and 80% of patients treated with anal self-massage using a finger showed disappearance of their anal fissures. A comparison between signs and symptoms reported by the patients in the two groups showed a statistically significant reduction in anal pain (group A, P=0.0001; group B, P=0.0001) and bleeding after defecation (group A, P=0.001, group B, P=0.001). At 6 months after treatment, a significantly greater reduction in anal pain was observed in Group A compared to Group B (P=0.02). The use of anal self-massage with a finger appears to induce a better resolution of acute anal fissure than do anal dilators, and in a shorter time.

  15. Energy efficient face seal

    NASA Technical Reports Server (NTRS)

    Sehnal, J.; Sedy, J.; Etsion, I.; Zobens, A.

    1982-01-01

    Torque, face temperature, leakage, and wear of a flat face seal were compared with three coned face seals at pressures up to 2758 kPa and speeds up to 8000 rpm. Axial movement of the mating seal parts was recorded by a digital data acquisition system. The coning of the tungsten carbide primary ring ranged from .51 micro-m to 5.6 micro-m. The torque of the coned face seal balanced to 76.3% was an average 42% lower, the leakage eleven times higher, than that of the standard flat face seal. The reduction of the balance of the coned face seal to 51.3% resulted by decreasing the torque by an additional 44% and increasing leakage 12 to 230 times, depending on the seal shaft speed. No measurable wear was observed on the face of the coned seals.

  16. Shift from magmatic to phreatomagmatic explosion controlled by the evolution of lateral fissure eruption in Suoana Crater, Miyakejima

    NASA Astrophysics Data System (ADS)

    Geshi, Nobuo; Nemeth, Karoly; Noguchi, Rina; Oikawa, Teruki

    2016-04-01

    Combined analysis of the proximal deposit and exposed feeder-diatreme structure of the Suoana Crater of Miyakejima reveals the process of magma-water interaction controlled by the evolution of lateral fissure eruption in a stratovolcanic edifice. The Suoana Crater, an oval maar with 400 x 300 m across is one of the craters of the Suoana-Kazahaya crater chain which is formed during a fissure eruption in the 7th Century. The eruption fissure extends ~3 km from the summit area (~700 m asl) to the lower-flank area (~200m asl). The eruption fissure consists of upper maar-chain (>450 m asl) and lower scora-cone chain. As the wall of the 2000 AD caldera truncated at near the center of the Suoana Crater, the vertical section of the feeder dike - diatreme - maar system of the Suoana Crater is exposed in the caldera wall (Geshi et al., 2011). The ejected materials from the Suoana crater indicate the transition of eruption style from magmatic to phreatomagmatic. The juvenile clasts in the lower half of the deposit exhibit spatter-like shape, indicating the typical deposit from a vigorous fire fountain. Contrary, the juvenile clasts in the upper half are less vesiculated and exhibit cauliflower-shape, indicating the typical phreatomagmatic activity. This transition indicates that the magma-water interaction started at the middle of the eruption. Judging from the ratio of the thickness of the lower and upper parts, the contrast of the content of juvenile clasts, and bulk density of the deposit, the total ejected volume of magma is larger in the lower part compare to the upper part. The transition from magmatic to phreatomagmatic occurred only in the upper half of the eruption fissure, including the Suoana crater, whereas the lower half of the fissure continued dry magmatic eruption throughout their activity. The limited distribution of phreatomagmatic activity can be resulted by the magma extraction from the upper feeder dike system to the lower eruption fissure as it

  17. SSME Seal Test Program: Test results for sawtooth pattern damper seal

    NASA Technical Reports Server (NTRS)

    Childs, D. W.

    1986-01-01

    Direct and transverse force coefficients for 11, sawtooth-pattern, and damper-seal configurations were examined. The designation damper seal uses a deliberately roughened stator and smooth rotor to increase the net damping force developed by a seal. The designation sawtooth-pattern refers to a stator roughness pattern. The sawtooth pattern yields axial grooves in the stator which are interrupted by spacer elements which act as flow constrictions or dams. All seals use the same smooth rotor and have the same, constant, minimum clearance. The stators examined the consequences of changes in the following design parameters: (1) axial-groove depth; (2) number of teeth: (3) number of sawtooth sections; (4) number of spacer elements; (5) dam width; (6) axially aligned sawtooth sections versus axially-staggered sawtooth sections; and (7) groove geometry. It is found that none of the sawtooth-pattern seal performs as well as the best round-hole-pattern seal. Maximum damping configurations for the sawtooth and round-hole-pattern stators have comparable stiffness performance. Several of the sawtooth pattern stators outperformed the best round-hole pattern seal.

  18. Collapsable seal member

    DOEpatents

    Sherrell, Dennis L.

    1990-01-01

    A hollow, collapsable seal member normally disposed in a natural expanded state offering fail-safe pressure sealing against a seating surface and adapted to be evacuated by a vacuum force for collapsing the seal member to disengage the same from said seating surface.

  19. Circumferential shaft seal

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A circumferential shaft seal comprising two sealing rings held to a rotating shaft by means of a surrounding elastomeric band is disclosed. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  20. Collapsable seal member

    DOEpatents

    Sherrell, D.L.

    1983-12-08

    A hollow, collapsable seal member normally disposed in a natural expanded state offering fail-safe pressure sealing against a seating surface and adapted to be evacuated by a vacuum force for collapsing the seal member to disengage the same from said seating surface.

  1. Increased anal basal pressure in chronic anal fissures may be caused by overreaction of the anal-external sphincter continence reflex.

    PubMed

    van Meegdenburg, Maxime M; Trzpis, Monika; Heineman, Erik; Broens, Paul M A

    2016-09-01

    Chronic anal fissure is a painful disorder caused by linear ulcers in the distal anal mucosa. Even though it counts as one of the most common benign anorectal disorders, its precise etiology and pathophysiology remains unclear. Current thinking is that anal fissures are caused by anal trauma and pain, which leads to internal anal sphincter hypertonia. Increased anal basal pressure leads to diminished anodermal blood flow and local ischemia, which delays healing and leads to chronic anal fissure. The current treatment of choice for chronic anal fissure is either lateral internal sphincterotomy or botulinum toxin injections. In contrast to current thinking, we hypothesize that the external, rather than the internal, anal sphincter is responsible for increased anal basal pressure in patients suffering from chronic anal fissure. We think that damage to the anal mucosa leads to hypersensitivity of the contact receptors of the anal-external sphincter continence reflex, resulting in overreaction of the reflex. Overreaction causes spasm of the external anal sphincter. This in turn leads to increased anal basal pressure, diminished anodermal blood flow, and ischemia. Ischemia, finally, prevents the anal fissure from healing. Our hypothesis is supported by two findings. The first concerned a chronic anal fissure patient with increased anal basal pressure (170mmHg) who had undergone lateral sphincterotomy. Directly after the operation, while the submucosal anesthetic was still active, basal anal pressure decreased to 80mmHg. Seven hours after the operation, when the anesthetic had completely worn off, basal anal pressure increased again to 125mmHg, even though the internal anal sphincter could no longer be responsible for the increase. Second, in contrast to previous studies, recent studies demonstrated that botulinum toxin influences external anal sphincter activity and, because it is a striated muscle relaxant, it seems reasonable to presume that it affects the striated

  2. Seals Flow Code Development 1993

    NASA Technical Reports Server (NTRS)

    Liang, Anita D. (Compiler); Hendricks, Robert C. (Compiler)

    1994-01-01

    Seals Workshop of 1993 code releases include SPIRALI for spiral grooved cylindrical and face seal configurations; IFACE for face seals with pockets, steps, tapers, turbulence, and cavitation; GFACE for gas face seals with 'lift pad' configurations; and SCISEAL, a CFD code for research and design of seals of cylindrical configuration. GUI (graphical user interface) and code usage was discussed with hands on usage of the codes, discussions, comparisons, and industry feedback. Other highlights for the Seals Workshop-93 include environmental and customer driven seal requirements; 'what's coming'; and brush seal developments including flow visualization, numerical analysis, bench testing, T-700 engine testing, tribological pairing and ceramic configurations, and cryogenic and hot gas facility brush seal results. Also discussed are seals for hypersonic engines and dynamic results for spiral groove and smooth annular seals.

  3. Acute stroke with major intracranial vessel occlusion: Characteristics of cardioembolism and atherosclerosis-related in situ stenosis/occlusion.

    PubMed

    Horie, Nobutaka; Tateishi, Yohei; Morikawa, Minoru; Morofuji, Yoichi; Hayashi, Kentaro; Izumo, Tsuyoshi; Tsujino, Akira; Nagata, Izumi; Matsuo, Takayuki

    2016-10-01

    Acute ischemic stroke with major intracranial vessel occlusion is commonly due to cardioembolic or atherosclerosis-related in situ stenosis/occlusion, and immediate identification of these subtypes is important to establish the optimal treatment strategy. The aim of this study was to clarify the differences in clinical presentation, radiological findings, neurological temporal courses, and outcomes between these etiologies, which have not been fully evaluated. Consecutive emergency patients with acute ischemic stroke were retrospectively reviewed. Among them, patients with stroke with major intracranial vessel occlusion were analyzed with a focus on clinical and radiological findings, and a comparison was performed for those with cardioembolic or atherosclerosis-related in situ stenosis/occlusion. Of 1053 patients, 80 had stroke with acute major intracranial vessel occlusion (45 with cardioembolic and 35 with atherosclerosis-related in situ stenosis/occlusion). Interestingly, the susceptibility vessel sign (SVS) on T2-weighted MR angiography was more frequently detected in cardioembolic stroke (80.0%) than in atherosclerosis (in situ stenosis: 5.9%, chronic occlusion: 14.3%). Moreover, the proximal intra-arterial signal (IAS) on arterial spin labeling MRI and the distal IAS on fluid attenuated inversion recovery MRI was less frequently detected in chronic occlusion (27.3% and 50.0%, respectively) than in acute occlusion due to cardioembolic or in situ stenosis. Multivariate regression analysis showed that the SVS was significantly related to cardioembolism (adjusted odds ratio (OR): 21.68, P=0.004). Clinical characteristics of acute stroke with major intracranial vessel occlusion differ depending on the etiology. The SVS and proximal/distal IAS on MRI are useful to distinguish between cardioembolic and atherosclerotic-related in situ stenosis/occlusion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Transmission seal development

    NASA Technical Reports Server (NTRS)

    Brien, M.

    1977-01-01

    An experimental evaluation was performed on a high-speed (72.9 m/s, 14,349 ft/min) transmission seal of the synergistic type. During testing of the seal, oil leakage occurred at positive bearing cavity pressures. Modifications were made in an attempt to eliminate the leakage but none were completely successful. Leakage appears to be the result of questionable positioning of the sealing elements resulting in inadequate shaft contact by the oil side sealing element. This condition may be related to the nonsymmetrical shape of the elastomeric retainer and to dimensional changes caused by swelling of the elastomeric retainer from exposure to the sealed fluid. Indications of a speed dependent leakage characteristic were also observed.

  5. Medium-term results of anal advancement flap compared with lateral sphincterotomy for the treatment of anal fissure.

    PubMed

    Patel, Sanjay D; Oxenham, Tom; Praveen, Bhandhipalyan V

    2011-09-01

    Anal fissure is associated with anal pain and bleeding. Lateral internal sphincterotomy (LIS) has been a common form of surgical management. This can however cause incontinence and hence an equally effective alternative without this risk would be ideal. Anal fissurectomy and an anal advancement flap (AAF) have been used as an alternative to LIS. We carried out a retrospective analysis of the results of AAF and LIS for the treatment of anal fissure. Fifty patients underwent AAF and a further 50 cases were chosen who had undergone LIS over the same time period. Patient and procedural data were collected including post-operative course. Presenting symptoms included anal pain (94%), rectal bleeding (77%) and constipation (15%). Mean (±SD) follow-up was 20 ± 12 months in the AAF group vs 22 ± 12.5 months in the LIS group. Healing of fissure was achieved in 96% of patients after AAF and 88% after LIS (p = 0.27). Resolution of symptoms was achieved in 90% after AAF and 72% of patients after LIS (p = 0.04). LIS was associated with an increased incidence of readmission with infection and pain (8% vs 4%, p = 0.35). Seven patients whom had undergone successful AAF with complete resolution of symptoms had previously had LIS with failure of symptom relief. There was no incidence of faecal incontinence in either group. AAF is associated with a higher incidence of symptomatic relief and fissure healing and lower incidence of complications when compared with LIS. AAF is effective at healing fissures which are refractory to LIS.

  6. Foil Face Seal Testing

    NASA Technical Reports Server (NTRS)

    Munson, John

    2009-01-01

    In the seal literature you can find many attempts by various researchers to adapt film riding seals to the gas turbine engine. None have been successful, potential distortion of the sealing faces is the primary reason. There is a film riding device that does accommodate distortion and is in service in aircraft applications, namely the foil bearing. More specifically a foil thrust bearing. These are not intended to be seals, and they do not accommodate large axial movement between shaft & static structure. By combining the 2 a unique type of face seal has been created. It functions like a normal face seal. The foil thrust bearing replaces the normal primary sealing surface. The compliance of the foil bearing allows the foils to track distortion of the mating seal ring. The foil seal has several perceived advantages over existing hydrodynamic designs, enumerated in the chart. Materials and design methodology needed for this application already exist. Also the load capacity requirements for the foil bearing are low since it only needs to support itself and overcome friction forces at the antirotation keys.

  7. Recurrence of amblyopia after occlusion therapy.

    PubMed

    Bhola, Rahul; Keech, Ronald V; Kutschke, Pamela; Pfeifer, Wanda; Scott, William E

    2006-11-01

    To determine the stability of visual acuity (VA) after a standardized occlusion regimen in children with strabismic and/or anisometropic amblyopia. Retrospective, population-based, consecutive observational case series. Four hundred forty-nine patients younger than 10 years who underwent an occlusion trial for amblyopia and were observed until there was a recurrence of amblyopia or for a maximum of 1 year after decrease or cessation of occlusion therapy. We performed a retrospective chart review of all patients treated by occlusion therapy for strabismic and/or anisometropic amblyopia at our institution over a 34-year period. Of the 1621 patients identified in our database, 449 met the eligibility criteria and were included in this study. Patients having at least a 2 logarithm of the minimum angle of resolution (logMAR)-level improvement in VA by optotypes or a change from unmaintained to maintained fixation preference during the course of occlusion therapy were included. A recurrence of amblyopia was defined as > or =2 logMAR levels of VA reduction or reversal of fixation preference within 1 year after a decrease or cessation of occlusion therapy. Recurrence of amblyopia after a decrease or cessation of occlusion therapy and its relationship with patient age and VA of the amblyopic eye at the time of decrease or cessation of occlusion therapy. Of 653 occlusion trials, 179 (27%) resulted in recurrence of amblyopia. The recurrence was found to be inversely correlated with patient age. There was no statistically significant association between the recurrence of amblyopia and VA of the amblyopic eye at the end of maximal occlusion therapy. There is a clinically important risk of amblyopia recurrence when occlusion therapy is decreased before the age of 10 years. The risk of recurrence is inversely correlated with age (P<0.0001).

  8. Circumferential shaft seal

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1980-01-01

    A circumferential shaft seal is described which comprises two sealing rings held to a rotating shaft by means of a surrounding elastomeric band. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  9. Turbomachine Interface Sealing

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Chupp, Raymond E.; Lattime, Scott B.; Steinetz, Bruce M.

    2005-01-01

    Sealing interfaces and coatings, like lubricants, are sacrificial, giving up their integrity for the benefit of the component. Clearance control is a major issue in power systems turbomachine design and operational life. Sealing becomes the most cost-effective way to enhance system performance. Coatings, films, and combined use of both metals and ceramics play a major role in maintaining interface clearances in turbomachine sealing and component life. This paper focuses on conventional and innovative materials and design practices for sealing interfaces.

  10. SSME seal test program: Test results for hole-pattern damper seals

    NASA Technical Reports Server (NTRS)

    Childs, D. W.

    1985-01-01

    The results consisting of direct and transverse force coefficients are presented for thirteen, hole-pattern, damper-seal configurations. The designation damper seal refers to a seal which uses a deliberately roughened stator nd smooth rotor, to increase the net damping force developed by a seal. The designation hole-pattern refers to a stator roughness pattern which is developed by a pattern of round holes while are milled into the stator. All seals tested use the same smooth rotor and have the same constant minimum clearance. The seal tests examined the following major design options: (1) hole-area density, i.e., the proportion of stator surface area consumed by holes; and (2) hole depth, particularly the ratio of hole depth to minimum clearance. In addition, limited data were taken to examine the influence of in-line versus staggered hole patterns and flat-bottomed versus spherical-bottomed holes.

  11. Double-porosity models for a fissured groundwater reservoir with fracture skin

    USGS Publications Warehouse

    Moench, Allen F.

    1984-01-01

    Theories of flow to a well in a double-porosity groundwater reservoir are modified to incorporate effects of a thin layer of low-permeability material or fracture skin that may be present at fracture-block interfaces as a result of mineral deposition or alteration. The commonly used theory for flow in double- porosity formations that is based upon the assumption of pseudo–steady state block-to-fissure flow is shown to be a special case of the theory presented in this paper. The latter is based on the assumption of transient block-to-fissure flow with fracture skin. Under conditions where fracture skin has a hydraulic conductivity that is less than that of the matrix rock, it may be assumed to impede the interchange of fluid between the fissures and blocks. Resistance to flow at fracture-block interfaces tends to reduce spatial variation of hydraulic head gradients within the blocks. This provides theoretical justification for neglecting the divergence of flow in the blocks as required by the pseudo–steady state flow model. Coupled boundary value problems for flow to a well discharging at a constant rate were solved in the Laplace domain. Both slab-shaped and sphere-shaped blocks were considered, as were effects of well bore storage and well bore skin. Results obtained by numerical inversion were used to construct dimensionless-type curves that were applied to well test data, for a pumped well and for an observation well, from the fractured volcanic rock terrane of the Nevada Test Site.

  12. Canister, Sealing Method And Composition For Sealing A Borehole

    DOEpatents

    Brown, Donald W.; Wagh, Arun S.

    2005-06-28

    Method and composition for sealing a borehole. A chemically bonded phosphate ceramic sealant for sealing, stabilizing, or plugging boreholes is prepared by combining an oxide or hydroxide and a phosphate with water to form slurry. The slurry is introduced into the borehole where the seal, stabilization or plug is desired, and then allowed to set up to form the high strength, minimally porous sealant, which binds strongly to itself and to underground formations, steel and ceramics.

  13. Comparative study of Ksharasutra suturing and Lord's anal dilatation in the management of Parikartika (chronic fissure-in-ano)

    PubMed Central

    Dudhamal, Tukaram S.; Baghel, Madhav Singh; Bhuyan, Chaturbhuja; Gupta, Sanjay Kumar

    2014-01-01

    Background: Parikartika resembles fissure-in-ano which is very common among all ano-rectal disorders. In Ayurvedic texts, Parikartika is described as a complication of Vamana and Virechana as well as complication of Atisara. Ksharasutra was proved successful in the management of fistula-in-ano, piles, and there is a need to try its efficacy in fissure-in-ano. Aim: To evaluate the role of Ksharasutra suturing (KSS) in fissure bed in chronic fissure-in-ano. Materials and Methods: Total 100 patients of chronic fissure-in-ano were selected and randomly divided into two groups (50 in each group). In group-A, patients were undergone by KSS; while in patients of Group-B Lord's anal dilatation followed by KSS was done under spinal anesthesia. The KSS was done once and after slough out of Ksharasutra, the wound was treated for 4 weeks and assessment of the result was done on the basis of gradation adopted. Results: The pain relief on 14th day in Group-A was 86% while in Group-B 100% was observed. As on 7th day in Group-A, oozing was stopped in 68% patients, while in Group-B, oozing was stopped in 82% patients. On 21st day, Group-B showed more healing (85%) as compared to Group-A (69%). In this study 68% of patients were cured. Conclusion: In Group-B (KSS with Lord's anal dilatation) patients were cured early as compared to patients of Group-A (KSS alone). PMID:25558158

  14. Comparative study of Ksharasutra suturing and Lord's anal dilatation in the management of Parikartika (chronic fissure-in-ano).

    PubMed

    Dudhamal, Tukaram S; Baghel, Madhav Singh; Bhuyan, Chaturbhuja; Gupta, Sanjay Kumar

    2014-04-01

    Parikartika resembles fissure-in-ano which is very common among all ano-rectal disorders. In Ayurvedic texts, Parikartika is described as a complication of Vamana and Virechana as well as complication of Atisara. Ksharasutra was proved successful in the management of fistula-in-ano, piles, and there is a need to try its efficacy in fissure-in-ano. To evaluate the role of Ksharasutra suturing (KSS) in fissure bed in chronic fissure-in-ano. Total 100 patients of chronic fissure-in-ano were selected and randomly divided into two groups (50 in each group). In group-A, patients were undergone by KSS; while in patients of Group-B Lord's anal dilatation followed by KSS was done under spinal anesthesia. The KSS was done once and after slough out of Ksharasutra, the wound was treated for 4 weeks and assessment of the result was done on the basis of gradation adopted. The pain relief on 14(th) day in Group-A was 86% while in Group-B 100% was observed. As on 7(th) day in Group-A, oozing was stopped in 68% patients, while in Group-B, oozing was stopped in 82% patients. On 21(st) day, Group-B showed more healing (85%) as compared to Group-A (69%). In this study 68% of patients were cured. In Group-B (KSS with Lord's anal dilatation) patients were cured early as compared to patients of Group-A (KSS alone).

  15. Laterally Translating Seal Carrier For A Drilling Mud Motor Sealed Bearing Assembly

    DOEpatents

    Dietle, Lannie

    1993-03-23

    A sealing and lubrication assembly for rotating shafts intended for operation in an abrasive environment and wherein the rotary shaft may have lateral translation or excursion during its rotation. A housing receives the rotary shaft in bearing supporting relation and defines a lubricant chamber about the shaft. A seal carrier is movably positioned about the rotary shaft and has non-rotatable articulating or laterally translating relation with the housing. A high pressure rotary shaft seal is supported by the seal carrier and maintains bearing and sealing engagement with the rotary shaft during its lateral translation or excursion. The seal carrier is hydraulic force balanced and thus is not subject to pressure induced loads that might otherwise interfere with its articulation or lateral translation.

  16. [Temporomandibular joint, occlusion and bruxism].

    PubMed

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Resilient Flexible Pressure-Activated Seal

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor); Dunlap, Patrick H., Jr. (Inventor)

    2009-01-01

    A resilient, flexible, pressure-activated, high-temperature seal is adapted to be interposed between high and low pressure regions to provide sealing between opposing surfaces of adjacent relatively movable structures. The seal comprises at least one C-shaped sheet element. The C-shaped element design enables the seal to be pressure-activated to provide a radially outward biasing force, responsive to a seal-activating pressure differential acting across the seal thereby increasing resiliency. A centrally-located, resilient core structure provides load bearing and insulating properties. In an exemplary embodiment where at least two seal elements are used, each layer has a cutout slot pattern and the remaining strip material pattern. The slots provide flexibility to the seal, enabling the seal to be manually contoured to seal around corners and curves. The strip material of each layer covers the slots in each adjacent layer to minimize leakage through the slots. Attached barrier strips can block interface leakage between the seal and the opposing surfaces.

  18. Design guide for helicopter transmission seals

    NASA Technical Reports Server (NTRS)

    Hayden, T. S.; Keller, C. H., Jr.

    1974-01-01

    A detailed approach for the selection and design of seals for helicopter transmissions is presented. There are two major types of seals presently being used and they are lip type seals and mechanical type seals. Lip type seals can be divided in conventional lip seals and hydrodynamic lip seals. Conventional lip seals can be used for slow-speed, low-pressure, low-temperature sealing. Hydrodynamic lip seals although they are as pressure and temperature limited as conventional lip seals, can operate at a higher speed. Mechanical types seals are comprised of face seals and circumferential seals. Face seals are capable of high speed, high pressure, and high temperature. Circumferential seals can be used in high-speed and high-temperature applications, but will leak excessively at moderate pressures. The performance goals of transmission seals are a life that is at least equal to the scheduled overhaul interval of the gearbox component and a leakage rate of near zero.

  19. P-proteins in Arabidopsis are heteromeric structures involved in rapid sieve tube sealing.

    PubMed

    Jekat, Stephan B; Ernst, Antonia M; von Bohl, Andreas; Zielonka, Sascia; Twyman, Richard M; Noll, Gundula A; Prüfer, Dirk

    2013-01-01

    Structural phloem proteins (P-proteins) are characteristic components of the sieve elements in all dicotyledonous and many monocotyledonous angiosperms. Tobacco P-proteins were recently confirmed to be encoded by the widespread sieve element occlusion (SEO) gene family, and tobacco SEO proteins were shown to be directly involved in sieve tube sealing thus preventing the loss of photosynthate. Analysis of the two Arabidopsis SEO proteins (AtSEOa and AtSEOb) indicated that the corresponding P-protein subunits do not act in a redundant manner. However, there are still pending questions regarding the interaction properties and specific functions of AtSEOa and AtSEOb as well as the general function of structural P-proteins in Arabidopsis. In this study, we characterized the Arabidopsis P-proteins in more detail. We used in planta bimolecular fluorescence complementation assays to confirm the predicted heteromeric interactions between AtSEOa and AtSEOb. Arabidopsis mutants depleted for one or both AtSEO proteins lacked the typical P-protein structures normally found in sieve elements, underlining the identity of AtSEO proteins as P-proteins and furthermore providing the means to determine the role of Arabidopsis P-proteins in sieve tube sealing. We therefore developed an assay based on phloem exudation. Mutants with reduced AtSEO expression levels lost twice as much photosynthate following injury as comparable wild-type plants, confirming that Arabidopsis P-proteins are indeed involved in sieve tube sealing.

  20. P-proteins in Arabidopsis are heteromeric structures involved in rapid sieve tube sealing

    PubMed Central

    Jekat, Stephan B.; Ernst, Antonia M.; von Bohl, Andreas; Zielonka, Sascia; Twyman, Richard M.; Noll, Gundula A.; Prüfer, Dirk

    2013-01-01

    Structural phloem proteins (P-proteins) are characteristic components of the sieve elements in all dicotyledonous and many monocotyledonous angiosperms. Tobacco P-proteins were recently confirmed to be encoded by the widespread sieve element occlusion (SEO) gene family, and tobacco SEO proteins were shown to be directly involved in sieve tube sealing thus preventing the loss of photosynthate. Analysis of the two Arabidopsis SEO proteins (AtSEOa and AtSEOb) indicated that the corresponding P-protein subunits do not act in a redundant manner. However, there are still pending questions regarding the interaction properties and specific functions of AtSEOa and AtSEOb as well as the general function of structural P-proteins in Arabidopsis. In this study, we characterized the Arabidopsis P-proteins in more detail. We used in planta bimolecular fluorescence complementation assays to confirm the predicted heteromeric interactions between AtSEOa and AtSEOb. Arabidopsis mutants depleted for one or both AtSEO proteins lacked the typical P-protein structures normally found in sieve elements, underlining the identity of AtSEO proteins as P-proteins and furthermore providing the means to determine the role of Arabidopsis P-proteins in sieve tube sealing. We therefore developed an assay based on phloem exudation. Mutants with reduced AtSEO expression levels lost twice as much photosynthate following injury as comparable wild-type plants, confirming that Arabidopsis P-proteins are indeed involved in sieve tube sealing. PMID:23840197

  1. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  2. Seal ring installation tool

    NASA Technical Reports Server (NTRS)

    Haselmaier, L. Haynes (Inventor)

    2004-01-01

    A seal ring tool that allows an installer to position a primary seal ring between hub ends of pipe flanges that are being assembled together. The tool includes a pivoting handle member and extension arms attached to the pivoting handle member. The ends of the arms have side indentation type longitudinal grooves angled toward one another for holding the primary seal ring in place between the hubs of respective pipes that are to be attached together. The arms of the tool can also have flat sides that can be used to abut against an optional second larger seal that is supported within a groove in one of the hub ends so that the second hub end can then be moved against the other side of the primary seal ring. Once the seal ring is positioned between the pipe hubs, the pipe hubs can be moved about the seal ring due to the flat sides of the arms of the tool. The tool eliminates the chances of damaging and contaminating seal rings being installed within pipe hubs that are being attached to one another.

  3. Seals Research at AlliedSignal

    NASA Technical Reports Server (NTRS)

    Ullah, M. Rifat

    1996-01-01

    A consortium has been formed to address seal problems in the Aerospace sector of Allied Signal, Inc. The consortium is represented by makers of Propulsion Engines, Auxiliary Power Units, Gas Turbine Starters, etc. The goal is to improve Face Seal reliability, since Face Seals have become reliability drivers in many of our product lines. Several research programs are being implemented simultaneously this year. They include: Face Seal Modeling and Analysis Methodology; Oil Cooling of Seals; Seal Tracking Dynamics; Coking Formation & Prevention; and Seal Reliability Methods.

  4. Hawaiian fissure fountains: Quantifying vent and shallow conduit geometry, episode 1 of the 1969-1974 Mauna Ulu eruption: Chapter 17

    USGS Publications Warehouse

    Parcheta, Carolyn; Fagents, Sarah; Swanson, Donald A.; Houghton, Bruce F.; Ericksen, Todd; Carey, Rebecca; Cayol, Valérie; Poland, Michael P.; Weis, Dominique

    2015-01-01

    Geometries of shallow magmatic pathways feeding volcanic eruptions are poorly constrained, yet many key interpretations about eruption dynamics depend on knowledge of these geometries. Direct quantification is difficult because vents typically become blocked with lava at the end of eruptions. Indirect geophysical techniques have shed light on some volcanic conduit geometries, but the scales are too coarse to resolve narrow fissures (widths typically 1 m). Kīlauea's Mauna Ulu eruption, which started with <50 m high Hawaiian fountains along a 4.5 km fissure on 24 May 1969, provides a unique opportunity to measure the detailed geometry of a shallow magmatic pathway, as the western vents remain unobstructed to depths >30 m. Direct measurements at the ground surface were augmented by tripod-mounted lidar measurements to quantify the shallow conduit geometry for three vents at a resolution <4 cm. We define the form of the fissure in terms of aspect ratio, flaring ratio, irregularity, sinuosity, and segmentation and discuss the factors influencing these parameters. In the past, simplified first-order fissure geometries have been used in computational modeling. Our data can provide more accurate conduit shapes for better understanding of shallow fissure fluid dynamics and how it controls eruptive behavior, especially if incorporated into computer models.

  5. Sodium sulfur battery seal

    DOEpatents

    Mikkor, Mati

    1981-01-01

    This disclosure is directed to an improvement in a sodium sulfur battery construction in which a seal between various battery compartments is made by a structure in which a soft metal seal member is held in a sealing position by holding structure. A pressure applying structure is used to apply pressure on the soft metal seal member when it is being held in sealing relationship to a surface of a container member of the sodium sulfur battery by the holding structure. The improvement comprises including a thin, well-adhered, soft metal layer on the surface of the container member of the sodium sulfur battery to which the soft metal seal member is to be bonded.

  6. Turbine disc sealing assembly

    DOEpatents

    Diakunchak, Ihor S.

    2013-03-05

    A disc seal assembly for use in a turbine engine. The disc seal assembly includes a plurality of outwardly extending sealing flange members that define a plurality of fluid pockets. The sealing flange members define a labyrinth flow path therebetween to limit leakage between a hot gas path and a disc cavity in the turbine engine.

  7. The effect of Saqez (Pistacia atlantica) ointment on the treatment of nipple fissure and nipple pain in breastfeeding women

    PubMed Central

    As’adi, Nayereh; Kariman, Nourossadat; Mojab, Faraz; Pourhoseingholi, Mohammad Amin

    2017-01-01

    Background Nipple fissure is a common problem in breastfeeding women, and the main reason for the early discontinuation of breastfeeding. Objective To determine the effect of Saqez (Pistacia atlantica) ointment on the treatment of nipple fissure and nipple pain in breastfeeding women. Methods This randomized clinical trial was conducted on 100 subjects admitted to the health centers in Tehran, Iran from mid-July to mid-November 2015. The subjects were randomly divided into two equal groups of 50 for the Saqez ointment group and the control group. The subjects were divided into the two groups through random allocation in Excel. The subjects were monitored on day 1, 3 and 7. Data were analyzed in SAS using the Cumulative Logit model and in SPSS-21 using Mann-Whitney, independent-samples t-test, the Chi square and Fisher’s exact test. Results No significant differences were observed between the two groups in terms of their demographic and fertility characteristics. The Cumulative Logit model showed that high levels of nipple fissure and pain were significantly less frequent in the Saqez group compared to the control group (p<0.001). There was about 83% reduction in the severity of fissure and 85 %in the severity of pain in the Saqez group compared to the control group (p<0.001). Conclusion Saqez ointment is more effective in the treatment of nipple fissures and pain than breast milk. As this study was done for the first time, judgment about the conclusive efficacy of Saqez ointment on the nipple fissure, needs further similar studies. Trial registration The trial was registered at the Iranian Registry of Clinical Trials (http://www.irct.ir) with the Irct ID: IRCT2015080723535N1. Funding The authors received no financial support for the research, authorship, and/or publication of this article. PMID:28979728

  8. Fine mapping and introgressing qFIS1-2, a major QTL for kernel fissure resistance in rice (Oryza sativa L.)

    USDA-ARS?s Scientific Manuscript database

    Rice (Oryza sativa L.) kernel fissuring increases breakage during milling and decreases the value of processed rice. This study employed molecular gene tagging methods to fine-map a fissure resistance (FR) locus in ‘Cybonnet’, a semidwarf tropical japonica cultivar, as well as transfer this trait to...

  9. Bidirectional Brush Seals

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Wilson, Jack; Wu, Tom; Flower, Ralph

    1997-01-01

    Presented is a study of the use of a set of I.D./O.D. bidirectional press seals to reduce the leakage losses in a wave rotor. Relative to the baseline configuration, data indicate the use of brush seals enhanced wave rotor efficiency from 36 to 45 percent at low leakages (small rotor endwall gap spacings) and from 15 to 33 percent at high leakages (larger endwall gap spacings). These brush seals are capable of sealing positive or negative pressure drops with respect to the axial direction. Surface tribology for these tests suggested little evidence of grooving although the bristles appeared polished.

  10. Overview of NASA Glenn Seal Program

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Proctor, Margaret P.; Dunlap, Patrick H., Jr.; Delgado, Irebert; DeMange, Jeffrey J.; Daniels, Christopher C.; Lattime, Scott B.

    2003-01-01

    The Seal Team is divided into four primary areas. These areas include turbine engine seal development, structural seal development, acoustic seal development, and adaptive seal development. The turbine seal area focuses on high temperature, high speed shaft seals for secondary air system flow management. The structural seal area focuses on high temperature, resilient structural seals required to accommodate large structural distortions for both space- and aero-applications. Our goal in the acoustic seal project is to develop non-contacting, low leakage seals exploiting the principles of advanced acoustics. We are currently investigating a new acoustic field known as Resonant Macrosonic Synthesis (RMS) to see if we can harness the large acoustic standing pressure waves to form an effective air-barrier/seal. Our goal in the adaptive seal project is to develop advanced sealing approaches for minimizing blade-tip (shroud) or interstage seal leakage. We are planning on applying either rub-avoidance or regeneration clearance control concepts (including smart structures and materials) to promote higher turbine engine efficiency and longer service lives.

  11. A hybrid floating brush seal (HFBS) for improved sealing and wear performance in turbomachinery applications

    NASA Astrophysics Data System (ADS)

    Lattime, Scott Byran

    A conceptually new type of seal has been developed for gas turbine applications which dramatically reduces wear and leakage associated with current labyrinth and brush seal technologies. The Hybrid Floating Brush Seal (HFBS) combines brush seal and film riding face seal technologies to create a hybrid seal that allows both axial and radial excursions of the sealed shaft, while simultaneously eliminating interface surface speeds (friction and heat) between the rotor and the brush material that characterize standard brush seal technology. A simple test rig was designed to evaluate feasibility of the HFBS under relatively low pressures and rotational speeds (50psig, 5krpm). A second test stand was created to study the effects of centrifugal force on bristle deflection. A third test facility was constructed for prototype development and extensive room temperature testing at moderate pressures and fairly high rotational speeds (100psig, 40krpm). This test rig also allowed the evaluation of the HFBS during axial movement of a rotating shaft. An analytical model to predict the effects of centrifugal force on the bristles of a rotating brush seal was developed. Room temperature analysis of the HFBS proved successful for relatively high operating rotational velocities at moderate pressures with very acceptable leakage rates for gas turbine engines. Brush seals were able to track rotor speeds up to 24krpm while maintaining sealing integrity. The HFBS's ability to function under axial shaft displacement and synchronous dynamic radial loading was also proven successful. Hydrodynamic performance of the face seal was proven to provide adequate stiffness and load carrying capacity to keep the brush seal from contacting the face seal at pressure drops across the brush of up to 100psi. Leakage performance over standard brush seal and labyrinth technology was quite dramatic. The HFBS showed its sealing advantage using much higher radial interference between the rotor and the bristle

  12. Hydrodynamic perception in true seals (Phocidae) and eared seals (Otariidae).

    PubMed

    Hanke, Wolf; Wieskotten, Sven; Marshall, Christopher; Dehnhardt, Guido

    2013-06-01

    Pinnipeds, that is true seals (Phocidae), eared seals (Otariidae), and walruses (Odobenidae), possess highly developed vibrissal systems for mechanoreception. They can use their vibrissae to detect and discriminate objects by direct touch. At least in Phocidae and Otariidae, the vibrissae can also be used to detect and analyse water movements. Here, we review what is known about this ability, known as hydrodynamic perception, in pinnipeds. Hydrodynamic perception in pinnipeds developed convergently to the hydrodynamic perception with the lateral line system in fish and the sensory hairs in crustaceans. So far two species of pinnipeds, the harbour seal (Phoca vitulina) representing the Phocidae and the California sea lion (Zalophus californianus) representing the Otariidae, have been studied for their ability to detect local water movements (dipole stimuli) and to follow hydrodynamic trails, that is the water movements left behind by objects that have passed by at an earlier point in time. Both species are highly sensitive to dipole stimuli and can follow hydrodynamic trails accurately. In the individuals tested, California sea lions were clearly more sensitive to dipole stimuli than harbour seals, and harbour seals showed a superior trail following ability as compared to California sea lions. Harbour seals have also been shown to derive additional information from hydrodynamic trails, such as motion direction, size and shape of the object that caused the trail (California sea lions have not yet been tested). The peculiar undulated shape of the harbour seals' vibrissae appears to play a crucial role in trail following, as it suppresses self-generated noise while the animal is swimming.

  13. A hot dynamic seal rig for measuring hypersonic engine seal durability and flow performance

    NASA Technical Reports Server (NTRS)

    Miller, Jeffrey H.; Steinetz, Bruce M.; Sirocky, Paul J.; Kren, Lawrence A.

    1993-01-01

    A test fixture for measuring the dynamic performance of candidate high-temperature engine seal concepts has been installed at NASA Lewis Research Center. The test fixture has been designed to evaluate seal concepts under development for advanced hypersonic engines, such as those being considered for the National Aerospace Plane (NASP). The fixture can measure dynamic seal leakage performance from room temperature up to 840 C (1550 F) and air pressure differentials up to 690 kPa (100 psi). Performance of the seals can be measured while sealing against flat or distorted walls. In the fixture two seals are preloaded against the sides of a 30 cm (1 ft) long saber that slides transverse to the axis of the seals, simulating the scrubbing motion anticipated in these engines. This report covers the capabilities of this test fixture along with preliminary data showing the dependence of seal leakage performance on high temperature cycling.

  14. A Hot Dynamic Seal Rig for Measuring Hypersonic Engine Seal Durability and Flow Performance

    NASA Technical Reports Server (NTRS)

    Miller, Jeffrey H.; Steinetz, Bruce M.; Sirocky, Paul J.; Kren, Lawrence A.

    1993-01-01

    A test fixture for measuring the dynamic performance of candidate high-temperature engine seal concepts was installed at NASA Lewis Research Center. The test fixture was designed to evaluate seal concepts under development for advanced hypersonic engines, such as those being considered for the National Aerospace Plane (NASP). The fixture can measure dynamic seal leakage performance from room temperature up to 840 C (1550 F) and air pressure differentials up to 690 kPa (100 psi). Performance of the seals can be measured while sealing against flat or distorted walls. In the fixture two seals are preloaded against the sides of a 30 cm (1 ft) long saber that slides transverse to the axis of the seals, simulating the scrubbing motion anticipated in these engines. The capabilities of this test fixture along with preliminary data showing the dependence of seal leakage performance on high temperature cycling are addressed.

  15. Shaft seal assembly and method

    NASA Technical Reports Server (NTRS)

    Keba, John E. (Inventor)

    2007-01-01

    A pressure-actuated shaft seal assembly and associated method for controlling the flow of fluid adjacent a rotatable shaft are provided. The seal assembly includes one or more seal members that can be adjusted between open and closed positions, for example, according to the rotational speed of the shaft. For example, the seal member can be configured to be adjusted according to a radial pressure differential in a fluid that varies with the rotational speed of the shaft. In addition, in the closed position, each seal member can contact a rotatable member connected to the shaft to form a seal with the rotatable member and prevent fluid from flowing through the assembly. Thus, the seal can be closed at low speeds of operation and opened at high speeds of operation, thereby reducing the heat and wear in the seal assembly while maintaining a sufficient seal during all speeds of operation.

  16. 30 CFR 57.8535 - Seals.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Seals. 57.8535 Section 57.8535 Mineral....8535 Seals. Seals shall be provided with a means for checking the quality of air behind the seal and a means to prevent a water head from developing unless the seal is designed to impound water. ...

  17. 30 CFR 57.8535 - Seals.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Seals. 57.8535 Section 57.8535 Mineral....8535 Seals. Seals shall be provided with a means for checking the quality of air behind the seal and a means to prevent a water head from developing unless the seal is designed to impound water. ...

  18. Resilient Braided Rope Seal

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor); Kren, Lawrence A. (Inventor)

    1996-01-01

    A resilient braided rope seal for use in high temperature applications. The resilient braided rope seal includes a center core of fibers, a resilient 5 member overbraided by at least one layer of braided sheath fibers tightly packed together. The resilient member adds significant stiffness to the seal while maintaining resiliency. Furthermore, the seal permanent set and hysteresis are greatly reduced. Finally, improved load capabilities are provided.

  19. Rotary shaft seal

    DOEpatents

    Langebrake, C.O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transucer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  20. Rotary shaft seal

    DOEpatents

    Langebrake, Clair O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transducer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  1. Sealing in Turbomachinery

    NASA Technical Reports Server (NTRS)

    Chupp, Raymond E.; Hendricks, Robert C.; Lattime, Scott B.; Steinetz, Bruce M.

    2006-01-01

    Clearance control is of paramount importance to turbomachinery designers and is required to meet today's aggressive power output, efficiency, and operational life goals. Excessive clearances lead to losses in cycle efficiency, flow instabilities, and hot gas ingestion into disk cavities. Insufficient clearances limit coolant flows and cause interface rubbing, overheating downstream components and damaging interfaces, thus limiting component life. Designers have put renewed attention on clearance control, as it is often the most cost effective method to enhance system performance. Advanced concepts and proper material selection continue to play important roles in maintaining interface clearances to enable the system to meet design goals. This work presents an overview of turbomachinery sealing to control clearances. Areas covered include: characteristics of gas and steam turbine sealing applications and environments, benefits of sealing, types of standard static and dynamics seals, advanced seal designs, as well as life and limitations issues.

  2. A systematic review and meta-analysis of the treatment of anal fissure.

    PubMed

    Nelson, R L; Manuel, D; Gumienny, C; Spencer, B; Patel, K; Schmitt, K; Castillo, D; Bravo, A; Yeboah-Sampong, A

    2017-08-01

    Anal fissure has a very large number of treatment options. The choice is difficult. In an effort to assist in that, choice presented here is a systematic review and meta-analysis of all published treatments for anal fissure that have been studied in randomized controlled trials. Randomized trials were sought in the Cochrane Controlled Trials Register, Medline, EMBASE and the trials registry sites clinicaltrials.gov and who/int/ictrp/search/en. Abstracts were screened, full-text studies chosen, and finally eligible studies selected and abstracted. The review was then divided into those studies that compared two or more surgical procedures and those that had at least one arm that was non-surgical. Studies were further categorized by the specific interventions and comparisons. The outcome assessed was treatment failure. Negative effects of treatment assessed were headache and anal incontinence. Risk of bias was assessed for each study, and the strength of the evidence of each comparison was assessed using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach. One hundred and forty-eight eligible trials were found and assessed, 31 in the surgical group and 117 in the non-surgical group. There were 14 different operations described in the surgical group and 29 different non-surgical treatments in the non-surgical group along with partial lateral internal sphincterotomy (LIS). There were 61 different comparisons. Of these, 47 were reported in 2 or fewer studies, usually with quite small patient samples. The largest single comparison was glyceryl trinitrate (GTN) versus control with 19 studies. GTN was more effective than control in sustained cure (OR 0.68; 95% CI 0.63-0.77), but the quality of evidence was very poor because of severe heterogeneity, and risk of bias due to inadequate clinical follow-up. The only comparison to have a GRADE quality of evidence of high was a subgroup analysis of LIS versus any medical therapy (OR 0.12; CI 0

  3. Mechanically expandable annular seal

    DOEpatents

    Gilmore, R.F.

    1983-07-19

    A mechanically expandable annular reusable seal assembly to form an annular hermetic barrier between two stationary, parallel, and planar containment surfaces is described. A rotatable ring, attached to the first surface, has ring wedges resembling the saw-tooth array of a hole saw. Matching seal wedges are slidably attached to the ring wedges and have their motion restricted to be perpendicular to the second surface. Each seal wedge has a face parallel to the second surface. An annular elastomer seal has a central annular region attached to the seal wedges' parallel faces and has its inner and outer circumferences attached to the first surface. A rotation of the ring extends the elastomer seal's central region perpendicularly towards the second surface to create the fluid tight barrier. A counter rotation removes the barrier. 6 figs.

  4. Seals Code Development Workshop

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C. (Compiler); Liang, Anita D. (Compiler)

    1996-01-01

    Seals Workshop of 1995 industrial code (INDSEAL) release include ICYL, GCYLT, IFACE, GFACE, SPIRALG, SPIRALI, DYSEAL, and KTK. The scientific code (SCISEAL) release includes conjugate heat transfer and multidomain with rotordynamic capability. Several seals and bearings codes (e.g., HYDROFLEX, HYDROTRAN, HYDROB3D, FLOWCON1, FLOWCON2) are presented and results compared. Current computational and experimental emphasis includes multiple connected cavity flows with goals of reducing parasitic losses and gas ingestion. Labyrinth seals continue to play a significant role in sealing with face, honeycomb, and new sealing concepts under investigation for advanced engine concepts in view of strict environmental constraints. The clean sheet approach to engine design is advocated with program directions and anticipated percentage SFC reductions cited. Future activities center on engine applications with coupled seal/power/secondary flow streams.

  5. Layered seal for turbomachinery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarawate, Neelesh Nandkumar; Morgan, Victor John; Weber, David Wayne

    2015-11-20

    The present application provides seal assemblies for reducing leakages between adjacent components of turbomachinery. The seal assemblies may include outer shims, and at least a portion of the outer shims may be substantially impervious. At least one of the outer shims may be configured for sealing engagement with seal slots of the adjacent components. The seal assemblies may also include at least one of an inner shim and a filler layer positioned between the outer shims. The at least one inner shim may be substantially solid and the at least one filler layer may be relatively porous. The seal assembliesmore » may be sufficiently flexible to account for misalignment between the adjacent components, sufficiently stiff to meet assembly requirements, and sufficiently robust to operating meet requirements associated with turbomachinery.« less

  6. Liquid zone seal

    DOEpatents

    Klebanoff, Leonard E.

    2001-01-01

    A seal assembly that provides a means for establishing multiple pressure zones within a system. The seal assembly combines a plate extending from the inner wall of a housing or inner enclosure that intersects with and is immersed in the fluid contained in a well formed in a tray contained within the enclosure. The fluid is a low vapor pressure oil, chemically inert and oxidation resistant. The use of a fluid as the sealing component provides a seal that is self-healing and mechanically robust not subject to normal mechanical wear, breakage, and formation of cracks or pinholes and decouples external mechanical vibrations from internal structural members.

  7. Ultra high vacuum seal arrangement

    DOEpatents

    Flaherty, Robert

    1981-01-01

    Arrangement for demountably sealing two concentric metallic tubes in an ultra high vacuum system which facilitates remote actuation. A tubular seal includes integral spaced lips which circumferentially engage the metallic tubes. The lips plastically deform the metallic tubes by mechanical forces resulting from a martensite to austenite transformation of the tubular seal upon application of a predetermined temperature. The sealing force is released upon application of another temperature which causes a transformation from the stronger austenite to the weaker martensite. Use of a dual acting sealing ring and driving ring circumferentially contacting the sealing ring is particularly applicable to sealing larger diameter concentric metallic members.

  8. Core disruptive accident margin seal

    DOEpatents

    Golden, Martin P.

    1979-01-01

    Apparatus for sealing the annulus defined within a substantially cylindrical rotatable riser assembly and plug combination of a nuclear reactor closure head. The apparatus comprises an inflatable sealing mechanism disposed in one portion of the riser assembly near the annulus such that upon inflation the sealing mechanism is radially actuated against the other portion of the riser assembly thereby sealing the annulus. The apparatus further comprises a connecting mechanism which places one end of the sealing mechanism in fluid communication with the reactor cover gas so that overpressurization of the reactor cover gas will increase the radial actuation of the sealing mechanism thus enhancing sealing of the annulus.

  9. Seal system with integral detector

    DOEpatents

    Fiarman, S.

    1982-08-12

    A seal system is disclosed for materials where security is of the essence, such as nuclear materials. The seal is tamper-indicating, indicates changes in environmental conditions that evidence attempts to bypass the seal, is unique and cost effective. The seal system is comprised of a seal where an optical signal is transmitted through a loop, with a detector to read said signal, and one or more additional detectors designed to detect environmental changes, these detectors being operatively associated with the seal so that detection of a break in the optical signal or detection of environmental changes will cause an observable change in the seal.

  10. Improved circumferential shaft seal

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P.; Strom, T. N.

    1974-01-01

    Comparative tests of modified and unmodified carbon ring seals showed that addition of helical grooves to conventional segmented carbon ring seals reduced leakage significantly. Modified seal was insensitive to shaft runout and to flooding by lubricant.

  11. Ground fissures in the area of Mavropigi Village (N. Greece): Seismotectonics or mining activity?

    NASA Astrophysics Data System (ADS)

    Kalogirou, Eleni; Tsapanos, Theodoros; Karakostas, Vassilios; Marinos, Vassilios; Chatzipetros, Alexandros

    2014-12-01

    In the beginning of July 2010, a ground fissure was observed in the field near the village of Mavropigi (Northern Greece) and specifically in its NW side. Later on (early September), a second ground fissure was perceived, close and almost parallel to the first one and very close to the limits of the lignite exploitation mine (by the Public Power Corporation, PPC). It was observed that the village of Mavropigi slides away slowly towards the PPC lignite mine. Geological, seismological, as well as geotechnical survey in the field indicated that the phenomenon is related to the coal mining exploitation in the near vicinity of the village rather than to any seismotectonic activity in the surrounding area.

  12. Ferrules seals

    DOEpatents

    Smith, James L.

    1984-01-01

    A device is provided for sealing an inner tube and an outer tube without excessively deforming the tubes. The device includes two ferrules which cooperate to form a vacuum-tight seal between the inner tube and outer tube and having mating surfaces such that overtightening is not possible.

  13. Can prevention eliminate caries?

    PubMed

    O'Mullane, D

    1995-07-01

    There are four main factors involved in the carious process: at-risk tooth structure, plaque flora, fermentable carbohydrates, and time. Based on our knowledge of the carious process, four main preventive strategies have been developed over the years, namely, fluorides, fissure sealing, dietary choice, and plaque control. Fluorides are having a major impact on smooth-surface caries; hence, strategies combining fluorides and fissure sealing are very effective. However, use of fissure sealing is still problematic. Changing dietary practices with a view to reducing dental caries seems to be having little impact on a global scale. Plaque control, as practiced routinely by the majority of people, is not sufficient to result in caries reductions. Deprivation and poverty are strongly associated with high caries levels. Although the preventive strategies currently available are likely to result in lower caries levels for many, for logistical reasons and because of factors associated with deprivation and poverty, caries is likely to remain a major public health problem in most communities for the foreseeable future.

  14. Air Force seal activities

    NASA Astrophysics Data System (ADS)

    Mayhew, Ellen R.

    1994-07-01

    Seal technology development is an important part of the Air Force's participation in the Integrated High Performance Turbine Engine Technology (IHPTET) initiative, the joint DOD, NASA, ARPA, and industry endeavor to double turbine engine capabilities by the turn of the century. Significant performance and efficiency improvements can be obtained through reducing internal flow system leakage, but seal environment requirements continue to become more extreme as the engine thermodynamic cycles advance towards these IHPTET goals. Brush seal technology continues to be pursued by the Air Force to reduce leakage at the required conditions. Likewise, challenges in engine mainshaft air/oil seals are also being addressed. Counter-rotating intershaft applications within the IHPTET initiative involve very high rubbing velocities. This viewgraph presentation briefly describes past and current seal research and development programs and gives a summary of seal applications in demonstrator and developmental engine testing.

  15. Investigation of positive shaft seals

    NASA Technical Reports Server (NTRS)

    Pfouts, J. O.

    1970-01-01

    Welded metal bellows secondary seals prevent secondary seal leakage with a minimum number of potential leak paths. High performance seal is obtained by controlling the potentially unstable seal-face movements induced by mechanical vibrations and fluid pressure pulsations.

  16. SEAL FOR ROTATING SHAFT

    DOEpatents

    Coffman, R.T.

    1957-12-10

    A seal is described for a rotatable shaft that must highly effective when the shaft is not rotating but may be less effective while the shaft is rotating. Weights distributed about a sealing disk secured to the shaft press the sealing disk against a tubular section into which the shiilt extends, and whem the shaft rotates, the centrifugal forces on the weights relieve the pressurc of the sealing disk against the tubular section. This action has the very desirible result of minimizing the wear of the rotating disk due to contact with the tubular section, while affording maximum sealing action when it is needed.

  17. High Pressure Rotary Shaft Sealing Mechanism

    DOEpatents

    Dietle, Lannie; Gobeli, Jeffrey D.

    2001-05-08

    A laterally translatable pressure staged rotary shaft sealing mechanism having a seal housing with a shaft passage therein being exposed to a fluid pressure P1 and with a rotary shaft being located within the shaft passage. At least one annular laterally translatable seal carrier is provided. First and second annular resilient sealing elements are supported in axially spaced relation by the annular seal carriers and have sealing relation with the rotary shaft. The seal housing and at least one seal carrier define a first pressure staging chamber exposed to the first annular resilient sealing element and a second pressure staging chamber located between and exposed to the first and second annular resilient sealing elements. A first fluid is circulated to the first pressure chamber at a pressure P1, and a second staging pressure fluid is circulated to the second pressure chamber at a fraction of pressure P1 to achieve pressure staging, cooling of the seals. Seal placement provides hydraulic force balancing of the annular seal carriers.

  18. Toward an Improved Hypersonic Engine Seal

    NASA Technical Reports Server (NTRS)

    Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; DeMange,Jeffrey J.; Taylor, Shawn C.

    2003-01-01

    High temperature, dynamic seals are required in advanced engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures from 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA s Glenn Research Center (GRC) is developing advanced seals to overcome these shortfalls. Two seal designs and two types of seal preloading devices were evaluated in a series of compression tests at room temperature and 2000 F and flow tests at room temperature. Both seals lost resiliency with repeated load cycling at room temperature and 2000 F, but seals with braided cores were significantly more flexible than those with cores composed of uniaxial ceramic fibers. Flow rates for the seals with cores of uniaxial fibers were lower than those for the seals with braided cores. Canted coil springs and silicon nitride compression springs showed promise conceptually as potential seal preloading devices to help maintain seal resiliency.

  19. Land subsidence and earth fissures in south-central and southern Arizona, USA

    NASA Astrophysics Data System (ADS)

    Conway, Brian D.

    2016-05-01

    Land subsidence due to groundwater overdraft has been an ongoing problem in south-central and southern Arizona (USA) since the 1940s. The first earth fissure attributed to excessive groundwater withdrawal was discovered in the early 1950s near Picacho. In some areas of the state, groundwater-level declines of more than 150 m have resulted in extensive land subsidence and earth fissuring. Land subsidence in excess of 5.7 m has been documented in both western metropolitan Phoenix and Eloy. The Arizona Department of Water Resources (ADWR) has been monitoring land subsidence since 2002 using interferometric synthetic aperture radar (InSAR) and since 1998 using a global navigation satellite system (GNSS). The ADWR InSAR program has identified more than 25 individual land subsidence features that cover an area of more than 7,300 km2. Using InSAR data in conjunction with groundwater-level datasets, ADWR is able to monitor land subsidence areas as well as identify areas that may require additional monitoring. One area of particular concern is the Willcox groundwater basin in southeastern Arizona, which is the focus of this paper. The area is experiencing rapid groundwater declines, as much as 32.1 m during 2005-2014 (the largest land subsidence rate in Arizona State—up to 12 cm/year), and a large number of earth fissures. The declining groundwater levels in Arizona are a challenge for both future groundwater availability and mitigating land subsidence associated with these declines. ADWR's InSAR program will continue to be a critical tool for monitoring land subsidence due to excessive groundwater withdrawal.

  20. Ferrules seals

    DOEpatents

    Smith, J.L.

    1984-07-10

    A device is provided for sealing an inner tube and an outer tube without excessively deforming the tubes. The device includes two ferrules which cooperate to form a vacuum-tight seal between the inner tube and outer tube and having mating surfaces such that overtightening is not possible. 3 figs.

  1. A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid.

    PubMed

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    2011-03-01

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.

  2. Why do seals have cones? Behavioural evidence for colour-blindness in harbour seals.

    PubMed

    Scholtyssek, Christine; Kelber, Almut; Dehnhardt, Guido

    2015-03-01

    All seals and cetaceans have lost at least one of two ancestral cone classes and should therefore be colour-blind. Nevertheless, earlier studies showed that these marine mammals can discriminate colours and a colour vision mechanism has been proposed which contrasts signals from cones and rods. However, these earlier studies underestimated the brightness discrimination abilities of these animals, so that they could have discriminated colours using brightness only. Using a psychophysical discrimination experiment, we showed that a harbour seal can solve a colour discrimination task by means of brightness discrimination alone. Performing a series of experiments in which two harbour seals had to discriminate the brightness of colours, we also found strong evidence for purely scotopic (rod-based) vision at light levels that lead to mesopic (rod-cone-based) vision in other mammals. This finding speaks against rod-cone-based colour vision in harbour seals. To test for colour-blindness, we used a cognitive approach involving a harbour seal trained to use a concept of same and different. We tested this seal with pairs of isoluminant stimuli that were either same or different in colour. If the seal had perceived colour, it would have responded to colour differences between stimuli. However, the seal responded with "same", providing strong evidence for colour-blindness.

  3. Borehole sealing method and apparatus

    DOEpatents

    Hartley, James N.; Jansen, Jr., George

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole.

  4. Static seal for turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salazar, Santiago; Gisch, Andrew

    2014-04-01

    A seal structure for a gas turbine engine, the seal structure including first and second components located adjacent to each other and forming a barrier between high and low pressure zones. A seal cavity is defined in the first and second components, the seal cavity extending to either side of an elongated gap extending generally in a first direction between the first and second components. A seal member is positioned within the seal cavity and spans across the elongated gap. The seal member includes first and second side edges extending into each of the components in a second direction transversemore » to the first direction, and opposing longitudinal edges extending between the side edges generally parallel to the first direction. The side edges include a groove formed therein for effecting a reduction of gas flow around the seal member at the side edges.« less

  5. Security seal. [Patent application

    DOEpatents

    Gobeli, G.W.

    1981-11-17

    Security for a package or verifying seal in plastic material is provided by a print seal with unique thermally produced imprints in the plastic. If tampering is attempted, the material is irreparably damaged and thus detectable. The pattern of the imprints, similar to fingerprints are recorded as a positive identification for the seal, and corresponding recordings made to allow comparison. The integrity of the seal is proved by the comparison of imprint identification records made by laser beam projection.

  6. Brush seals for cryogenic applications

    NASA Astrophysics Data System (ADS)

    Proctor, Margaret P.

    1994-07-01

    This viewgraph presentation presents test results of brush seals for cryogenic applications. Leakage for a single brush seal was two to three times less than for a 12-tooth labyrinth seal. The maximum temperature rise for a single brush seal was less than 50 R and occurred at 25 psid across the seal and 35,000 rpm. A static blowout test demonstrated sealing capability up to 550 psid. The seal limit was not obtained. The power loss for a single brush at 35,000 rpm and 175 psid was 2.45 hp. Two brushes far apart leak less than two brushes tight packed. Rotor wear was approximately 0.00075 mils and bristle wear was 1-3 mils after 4-1/2 hours.

  7. Endoscopic endonasal anatomy of superior orbital fissure and orbital apex regions: critical considerations for clinical applications.

    PubMed

    Dallan, Iacopo; Castelnuovo, Paolo; de Notaris, Matteo; Sellari-Franceschini, Stefano; Lenzi, Riccardo; Turri-Zanoni, Mario; Battaglia, Paolo; Prats-Galino, Alberto

    2013-05-01

    The superior orbital fissure is a critical three-dimensional space connecting the middle cranial fossa and the orbit. From an endoscopic viewpoint, only the medial aspect has a clinical significance. It presents a critical relationship with the lateral sellar compartment, the pterygopalatine fossa and the middle cranial fossa. The connective tissue layers and neural and vascular structures of this region are described. The role of Muller's muscle is confirmed, and the utility of the maxillary and optic strut is outlined. Muller's muscle extends for the whole length of the inferior orbital fissure, passes over the maxillary strut and enters the superior orbital fissure, representing a critical surgical landmark. Dividing the tendon between the medial and inferior rectus muscle allows the identification of the main trunk of the oculomotor nerve, and a little laterally, it is usually possible to visualize the first part of the ophthalmic artery. Based on a better knowledge of anatomy, we trust that this area could be readily addressed in clinical situations requiring an extended approach in proximity of the orbital apex.

  8. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  9. Stabilizing geometry for hydrodynamic rotary seals

    DOEpatents

    Dietle, Lannie L.; Schroeder, John E.

    2010-08-10

    A hydrodynamic sealing assembly including a first component having first and second walls and a peripheral wall defining a seal groove, a second component having a rotatable surface relative to said first component, and a hydrodynamic seal comprising a seal body of generally ring-shaped configuration having a circumference. The seal body includes hydrodynamic and static sealing lips each having a cross-sectional area that substantially vary in time with each other about the circumference. In an uninstalled condition, the seal body has a length defined between first and second seal body ends which varies in time with the hydrodynamic sealing lip cross-sectional area. The first and second ends generally face the first and second walls, respectively. In the uninstalled condition, the first end is angulated relative to the first wall and the second end is angulated relative to the second wall. The seal body has a twist-limiting surface adjacent the static sealing lip. In the uninstalled condition, the twist-limiting surface is angulated relative to the peripheral wall and varies along the circumference. A seal body discontinuity and a first component discontinuity mate to prevent rotation of the seal body relative to the first component.

  10. The effect of Saqez (Pistacia atlantica) ointment on nipple fissure improvement in breastfeeding women during one-month follow-up

    PubMed Central

    As’adi, Nayereh; Kariman, Nourossadat; Mojab, Faraz; Pourhoseingholi, Mohamad Amin

    2017-01-01

    Objective: Painful nipple fissure is a troublesome problem for breastfeeding mothers. This study was conducted to evaluate the effect of saqez (Pistacia atlantica) ointment on the improvement of nipple fissure in breastfeeding women during one-month follow-up. Materials and Methods: This randomized controlled clinical trial was conducted on 100 eligible women who visited the selected health centers affiliated to Shahid Beheshti University of Medical Sciences, Tehran, Iran, from July 2015 to December 2015 during their postpartum period. A total of 100 subjects were randomly divided into two equal groups of 50 women grouped as saqez ointment group and breast milk group, and followed-up for one month. Both groups received face-to-face instructions on breastfeeding techniques. For severity of nipple fissure, Storr scale and to measure the intensity of pain, visual analog scale (VAS) were used. Results: The results showed that the two groups were matched in terms of demographic and obstetric characteristics. Mean of nipple fissure severity in ointment group (42.62) was lower than that of the control group (48.02), that was significantly different between the two groups (p=0.047). In addition, Mean nipple pain intensity in ointment group (40.57) was lower than that of the control group (49.81), but there was no significant difference between the two groups (p=0.056). Conclusion: The present study showed that saqez ointment was more effective than breast milk in healing and controlling nipple fissures during one-month follow-up, without resulting in any side effects. PMID:29299430

  11. Sealing properties of mechanical seals for an axial flow blood pump.

    PubMed

    Tomioka, J; Mori, T; Yamazaki, K; Koyanagi, H

    1999-08-01

    A miniature intraventricular axial flow blood pump for left ventricular support is under development. One of the key technologies required for such pumps is sealing of the motor shaft. In this study, to prevent blood backflow into the motor side, mechanical seals were developed and their sealing properties investigated. In the experimental apparatus, the mechanical seal separated the bovine blood on the chamber side from the cooling water on the motor side. A leakage of the blood was measured by inductively coupled plasma (ICP) light emission analysis. The rate of hemolysis was measured by the cyanmethemoglobin method. Frictional torque acting on the shaft was measured by a torque transducer. In the experiments, the rotational speed of the shaft was changed from 1,000 to 10,000 rpm, and the contact force of the seal faces was changed from 1.96 to 4.31 N. To estimate lubrication regimes, the Stribeck curve, a diagram of the coefficient of friction against the bearing characteristic G number, was drawn. The results of the experiments showed that both the leakage of blood and the rate of hemolysis were very small. The friction loss was also very small. The mechanical seal was operated in various lubrication regimes, from a fluid lubrication regime to a mixed lubrication regime.

  12. Application of photogrammetry for analysis of occlusal contacts.

    PubMed

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Rim seal arrangement having pumping feature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ching-Pang; Myers, Caleb

    A rim seal arrangement for a gas turbine engine includes a first seal face on a rotor component, and a second seal face on a stationary annular rim centered about a rotation axis of the rotor component. The second seal face is spaced from the first seal face along an axial direction to define a seal gap. The seal gap is located between a radially outer hot gas path and a radially inner rotor cavity. The first seal face has a plurality of circumferentially spaced depressions, each having a depth in an axial direction and extending along a radial extentmore » of the first seal face. The depressions influence flow in the seal gap such that during rotation of the rotor component, fluid in the seal gap is pumped in a radially outward direction to prevent ingestion of a gas path fluid from the hot gas path into the rotor cavity.« less

  14. Regenerator cross arm seal assembly

    DOEpatents

    Jackman, Anthony V.

    1988-01-01

    A seal assembly for disposition between a cross arm on a gas turbine engine block and a regenerator disc, the seal assembly including a platform coextensive with the cross arm, a seal and wear layer sealingly and slidingly engaging the regenerator disc, a porous and compliant support layer between the platform and the seal and wear layer porous enough to permit flow of cooling air therethrough and compliant to accommodate relative thermal growth and distortion, a dike between the seal and wear layer and the platform for preventing cross flow through the support layer between engine exhaust and pressurized air passages, and air diversion passages for directing unregenerated pressurized air through the support layer to cool the seal and wear layer and then back into the flow of regenerated pressurized air.

  15. Nuclear instrumentation cable end seal

    DOEpatents

    Cannon, Collins P.; Brown, Donald P.

    1979-01-01

    An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates.

  16. Membrane Switches Check Seal Pressure

    NASA Technical Reports Server (NTRS)

    Hodgetts, P. J.; Stuckenberg, F. H.; Morrissey, E. T.

    1984-01-01

    Array of flexible membrane switches used to indicate closure of seal. Switch membrane responds to pressure exerted by rigid surface on compliant sealing medium and provides switch contacts monitored electronically. Membrane switches connected in series and placed under seal. When all switches are closed lamp or LED lights up, indicating requisite seal pressure has been realized at all switch positions. Principle used to ensure integrity of seals on refrigerator and oven doors, weatherstripping, hatches, spacecraft, airplanes, and submarines.

  17. Seal system with integral detector

    DOEpatents

    Fiarman, Sidney

    1985-01-01

    There is disclosed a seal system for materials where security is of the essence, such as nuclear materials, which is tamper-indicating, which indicates changes in environmental conditions that evidence attempts to by-pass the seal, which is unique and cost effective, said seal system comprised of a seal where an optical signal is transmitted through a loop, with a detector to read said signal, and one or more additional detectors designed to detect environmental changes, these detectors being operatively associated with the seal so that detection of a break in the optical signal or detection of environmental changes will cause an observable change in the seal.

  18. Occlusal wear and occlusal condition in a convenience sample of young adults.

    PubMed

    Van't Spijker, A; Kreulen, C M; Bronkhorst, E M; Creugers, N H J

    2015-01-01

    To study progression of tooth wear quantitatively in a convenient sample of young adults and to assess possible correlations with occlusal conditions. Twenty-eight dental students participated in a three-year follow up study on tooth wear. Visible wear facets on full arch gypsum casts were assessed using a flatbed scanner and measuring software. Regression analyses were used to assess possible associations between the registered occlusal conditions 'occlusal guidance scheme', 'vertical overbite', 'horizontal overbite', 'depth of sagittal curve', 'canine Angle class relation', 'history of orthodontic treatment', and 'self-reported grinding/clenching' (independent variables) and increase of wear facets (dependent variable). Mean increase in facet surface areas ranged from 1.2 mm2 (premolars, incisors) to 3.4 mm2 (molars); the relative increase ranged from 15% to 23%. Backward regression analysis showed no significant relation for 'group function', 'vertical overbite', 'depth of sagittal curve', 'history of orthodontic treatment' nor 'self-reported clenching. The final multiple linear regression model showed significant associations amongst 'anterior protected articulation' and 'horizontal overbite' and increase of facet surface areas. For all teeth combined, only 'anterior protected articulation' had a significant effect. 'Self reported grinding' did not have a significant effect (p>0.07). In this study 'anterior protected articulation' and 'horizontal overbite', were significantly associated with the progression of tooth wear. Self reported grinding was not significantly associated with progression of tooth wear. Occlusal conditions such as anterior protected articulation and horizontal overbite seem to have an effect on the progression of occlusal tooth wear in this convenient sample of young adults. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. SEALING MEANS FOR RELATIVELY ROTATABLE MEMBERS

    DOEpatents

    Skarstrom, C.S.

    1960-10-25

    A sealing means is offered for maintaining a seal between a pair of relatively rotatable members, panticularly between a rotating shaft and a stationary member surrounding the shaft. The sealing is accomplished by means of a flange extending outward radially on each of a plurality of sealing rings mounted on the rotating member which fit into annular grooves in the stationary member and are held in sealing relation therewith by means of spring rings. In addition, means are provided for passing a sealing gas through the seal sunfaces to prevent accumulation of lubricant and for scavenging any gas which may have leaked from the internal member into the seal area.

  20. Detecting natural occlusion boundaries using local cues

    PubMed Central

    DiMattina, Christopher; Fox, Sean A.; Lewicki, Michael S.

    2012-01-01

    Occlusion boundaries and junctions provide important cues for inferring three-dimensional scene organization from two-dimensional images. Although several investigators in machine vision have developed algorithms for detecting occlusions and other edges in natural images, relatively few psychophysics or neurophysiology studies have investigated what features are used by the visual system to detect natural occlusions. In this study, we addressed this question using a psychophysical experiment where subjects discriminated image patches containing occlusions from patches containing surfaces. Image patches were drawn from a novel occlusion database containing labeled occlusion boundaries and textured surfaces in a variety of natural scenes. Consistent with related previous work, we found that relatively large image patches were needed to attain reliable performance, suggesting that human subjects integrate complex information over a large spatial region to detect natural occlusions. By defining machine observers using a set of previously studied features measured from natural occlusions and surfaces, we demonstrate that simple features defined at the spatial scale of the image patch are insufficient to account for human performance in the task. To define machine observers using a more biologically plausible multiscale feature set, we trained standard linear and neural network classifiers on the rectified outputs of a Gabor filter bank applied to the image patches. We found that simple linear classifiers could not match human performance, while a neural network classifier combining filter information across location and spatial scale compared well. These results demonstrate the importance of combining a variety of cues defined at multiple spatial scales for detecting natural occlusions. PMID:23255731

  1. 14 CFR 65.133 - Seal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Seal. 65.133 Section 65.133 Aeronautics and...: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Parachute Riggers § 65.133 Seal. Each certificated parachute rigger must have a seal with an identifying mark prescribed by the Administrator, and a seal press. After...

  2. 14 CFR 65.133 - Seal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Seal. 65.133 Section 65.133 Aeronautics and...: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Parachute Riggers § 65.133 Seal. Each certificated parachute rigger must have a seal with an identifying mark prescribed by the Administrator, and a seal press. After...

  3. Advanced High Temperature Structural Seals

    NASA Technical Reports Server (NTRS)

    Newquist, Charles W.; Verzemnieks, Juris; Keller, Peter C.; Shorey, Mark W.; Steinetz, Bruce (Technical Monitor)

    2000-01-01

    This program addresses the development of high temperature structural seals for control surfaces for a new generation of small reusable launch vehicles. Successful development will contribute significantly to the mission goal of reducing launch cost for small, 200 to 300 lb payloads. Development of high temperature seals is mission enabling. For instance, ineffective control surface seals can result in high temperature (3100 F) flows in the elevon area exceeding structural material limits. Longer sealing life will allow use for many missions before replacement, contributing to the reduction of hardware, operation and launch costs. During the first phase of this program the existing launch vehicle control surface sealing concepts were reviewed, the aerothermal environment for a high temperature seal design was analyzed and a mock up of an arc-jet test fixture for evaluating seal concepts was fabricated.

  4. Turbine interstage seal with self-balancing capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, Jacob A; Jones, Russell B; Sexton, Thomas D

    An interstage seal for a turbine of a gas turbine engine, the interstage seal having a seal carrier with an axial extending seal tooth movable with a stator of the engine, and a rotor with a seal surface that forms the interstage seal with the seal tooth, where a magnetic force produced by two magnets and a gas force produced by a gas pressure acting on the seal carrier forms a balancing force to maintain a close clearance of the seal without the seal tooth contacting the rotor seal surfaces during engine operation. In other embodiments, two pairs of magnetsmore » produce first and second magnetic forces that balance the seal in the engine.« less

  5. Canister, sealing method and composition for sealing a borehole

    DOEpatents

    Brown, Donald W [Los Alamos, NM; Wagh, Arun S [Orland Park, IL

    2003-05-13

    Canister, sealing method and composition for sealing a borehole. The canister includes a container with slurry inside the container, one or more slurry exits at one end of the container, a pump at the other end of the container, and a piston inside that pushes the slurry though the slurry exit(s), out of the container, and into a borehole. An inflatable packer outside the container provides stabilization in the borehole. A borehole sealing material is made by combining an oxide or hydroxide and a phosphate with water to form a slurry which then sets to form a high strength, minimally porous material which binds well to itself, underground formations, steel and ceramics.

  6. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    PubMed Central

    2010-01-01

    Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p < 0.001). The changes in the mean HOP-BPOP differences on the x-axis (mediolateral) and the y-axis (anteroposterior) were significant (p < 0.05), whereas the change on the z-axis (superoinferior) was not significant (p > 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167

  7. Status of Understanding for Seal Materials

    NASA Technical Reports Server (NTRS)

    Brown, P. F.

    1984-01-01

    Material selection for mainshaft face and ring seals, labyrinth seals, accessory gearbox face seals, and lip seals are discussed in light of tribology requirements and a given seal application. Carbon graphite has been found to be one of the best sealing materials and it is widely used in current gas turbine mainshaft and accessory gearbox seals. Its popularity is due to its unique combination of properties which consists of dimensional stability, corrosion resistance, low friction, good self lubricating characteristics, high thermal conductivity and low thermal expansion, the latter two properties combining to provide good thermal shock resistance. A brief description of the seals and the requirements they must meet are discussed to provide insight into the limitations and advantages of the seals in containing the lubricant. A forecast is made of the operational requirements of main shaft and gearbox seals for advanced engines and candidate materials and coatings that may satisfy these advanced engine requirements.

  8. A magnetic fluid seal for rotary blood pumps: Behaviors of magnetic fluids in a magnetic fluid seal.

    PubMed

    Mitamura, Yoshinori; Yano, Tetsuya; Nakamura, Wataru; Okamoto, Eiji

    2013-01-01

    A magnetic fluid (MF) seal has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids (several days). We have developed an MF seal that has a shield mechanism. The seal was perfect for 275 days in water. To investigate the effect of a shield, behaviors of MFs in a seal in water were studied both experimentally and computationally. (a) Two kinds of MF seals, one with a shield and one without a shield, were installed in a centrifugal pump. Behaviors of MFs in the seals in water were observed with a video camera and high-speed microscope. In the seal without a shield, the surface of the water in the seal waved and the turbulent flow affected behaviors of the MFs. In contrast, MFs rotated stably in the seal with a shield in water even at high rotational speeds. (b) Computational fluid dynamics analysis revealed that a stationary secondary flow pattern in the seal and small velocity difference between magnetic fluid and water at the interface. These MF behaviors prolonged the life of an MF seal in water.

  9. 36 CFR 901.6 - Seal.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Seal. 901.6 Section 901.6... CORPORATION § 901.6 Seal. The Corporation may adopt a corporate seal which shall have the name of the Corporation and year of incorporation printed upon it. The seal may be used by causing it or a facsimile...

  10. 36 CFR 901.6 - Seal.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Seal. 901.6 Section 901.6... CORPORATION § 901.6 Seal. The Corporation may adopt a corporate seal which shall have the name of the Corporation and year of incorporation printed upon it. The seal may be used by causing it or a facsimile...

  11. Hermetic Seal Leak Detection Apparatus

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  12. Reusable, tamper-indicating seal

    DOEpatents

    Ryan, Michael J.

    1978-01-01

    A reusable, tamper-indicating seal comprises a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body -- visible from outside the seal -- adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same position. A new pattern of colored balls will appear in the segregated location when the seal is relocked.

  13. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhudesai, V., E-mail: v_prabhudesai@hotmail.com; Mitra, K.; West, D. J.

    2003-09-15

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome.

  14. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  15. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  16. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    PubMed

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  17. Acute left main coronary artery occlusion

    PubMed Central

    Burgazli, K. Mehmet; Bilgin, Mehmet; Soydan, Nedim; Chasan, Ridvan; Erdogan, Ali

    2013-01-01

    The treatment of an acute left main coronary artery occlusion still poses a challenge. In this case report we present a 50-year-old patient with an acute occlusion of the left main artery. After a successful angioplasty without “stenting” due to the complexity of the stenosis the patient underwent a successful bypass surgery. We discuss the therapeutic options of acute left main occlusion regarding medical, interventional and surgical options. PMID:24353543

  18. Double angle seal forming lubricant film

    DOEpatents

    Ernst, William D.

    1984-01-01

    A lubricated piston rod seal which inhibits gas leaking from a high pressure chamber on one side of the seal to a low pressure chamber on the other side of the seal. A liquid is supplied to the surface of the piston rod on the low pressure side of the seal. This liquid acts as lubricant for the seal and provides cooling for the rod. The seal, which can be a plastic, elastomer or other material with low elastic modulus, is designed to positively pump lubricant through the piston rod/seal interface in both directions when the piston rod is reciprocating. The capacity of the seal to pump lubricant from the low pressure side to the high pressure side is less than its capacity to pump lubricant from the high pressure side to the low pressure side which ensures that there is zero net flow of lubricant to the high pressure side of the seal. The film of lubricant between the seal and the rod minimizes any sliding contact and prevents the leakage of gas. Under static conditions gas leakage is prevented by direct contact between the seal and the rod.

  19. Flow induced force of labyrinth seal

    NASA Technical Reports Server (NTRS)

    Iwatsubo, T.; Motooka, N.; Kawai, R.

    1982-01-01

    Flow induced instability force due to a labyrinth seal is analyzed. An approximate solution is given for the partial differential equation representing the flow in labyrinth seal and it is compared with the finite difference method in order to verify the accuracy of both methods. The effects of difference of inlet and outlet pressures of the seal, deflection of pressure and mass flow from the steady state, rotor diameter, seal clearance, seal interval and seal number on the flow induced force of the seal are investigated and it is known that some of these factors are very influential on the flow induced force.

  20. Giant desiccation fissures on the Black Rock and Smoke Creek Deserts, Nevada

    USGS Publications Warehouse

    Willden, R.; Mabey, D.R.

    1961-01-01

    Open fissures, from 100 to several hundred feet apart, that have produced polygonal patterns on the Black Rock Desert, Nevada, are believed to be giant desiccation cracks resulting from a secular trend toward aridity in the last few decades. Similar features on the Smoke Creek Desert probably have the same origin.

  1. Turbine seal assembly

    DOEpatents

    Little, David A.

    2013-04-16

    A seal assembly that limits gas leakage from a hot gas path to one or more disc cavities in a turbine engine. The seal assembly includes a seal apparatus that limits gas leakage from the hot gas path to a respective one of the disc cavities. The seal apparatus comprises a plurality of blade members rotatable with a blade structure. The blade members are associated with the blade structure and extend toward adjacent stationary components. Each blade member includes a leading edge and a trailing edge, the leading edge of each blade member being located circumferentially in front of the blade member's corresponding trailing edge in a direction of rotation of the turbine rotor. The blade members are arranged such that a space having a component in a circumferential direction is defined between adjacent circumferentially spaced blade members.

  2. Rotatable seal assembly

    DOEpatents

    Logan, Clinton M.; Garibaldi, Jack L.

    1982-01-01

    An assembly is provided for rotatably supporting a rotor on a stator so that vacuum chambers in the rotor and stator remain in communication while the chambers are sealed from ambient air, which enables the use of a ball bearing or the like to support most of the weight of the rotor. The apparatus includes a seal device mounted on the rotor to rotate therewith, but shiftable in position on the rotor while being sealed to the rotor as by an O-ring. The seal device has a flat face that is biased towards a flat face on the stator, and pressurized air is pumped between the faces to prevent contact between them while spacing them a small distance apart to avoid the inflow of large amounts of air between the faces and into the vacuum chambers.

  3. Seal Related Development Activities at EG/G

    NASA Technical Reports Server (NTRS)

    Greiner, Harold F.

    1991-01-01

    Seal related development activities including modeling, analysis, and performance testing are described for several current seal related projects. Among the current seal related projects are the following: high pressure gas sealing systems for turbomachinery; brush seals for gas path sealing in gas turbines; and tribological material evaluation for wear surfaces in sealing systems.

  4. Inheritance of Occlusal Topography: A Twin Study

    PubMed Central

    Su, C-Y.; Corby, P.M.; Elliot, M.A.; Studen-Pavlovich, D.A.; Ranalli, D.N.; Rosa, B.; Wessel, J.; Schork, N.J.; Hart, T.C.; Bretz, W.A.

    2011-01-01

    Aim This was to determine the relative contribution of genetic factors on the morphology of occlusal surfaces of mandibular primary first molars by employing the twin study model. Methods The occlusal morphology of mandibular primary first molar teeth from dental casts of 9 monozygotic (MZ) twin pairs and 12 dizygotic (DZ) twin pairs 4 to 7 years old, were digitized by contact-type three-dimensional (3D) scanner. To compare the similarity of occlusal morphology between twin sets, each twin pair of occlusal surfaces was superimposed to establish the best fit by using computerized least squared techniques. Heritability was computed using a variance component model, adjusted for age and gender. Results DZ pairs demonstrated a greater degree of occlusal morphology variance. The total amount of difference in surface overlap was 0.0508 mm (0.0018 (inches) for the MZ (n=18) sample and 0.095 mm (0.0034 inches) for the DZ (n=24) sample and were not statistically significant (p=0.2203). The transformed mean differences were not statistically significantly different (p=0.2203). Heritability estimates of occlusal surface areas for right and left mandibular primary first molars were 97.5% and 98.2% (p<0.0001), respectively. Conclusions Occlusal morphology of DZ twin pairs was more variable than that of MZ twin pairs. Heritability estimates revealed that genetic factors strongly influence occlusal morphology of mandibular primary first molars. PMID:18328234

  5. Antipilferage Seal User’s Guide

    DTIC Science & Technology

    1997-10-01

    seal is properly installed, ensure that there is no free play between the seal body and the wire. Verify and record the serial number. During post...and Record - Once the seal is properly installed, ensure that there is no free play between the seal body and the wire. During post-mortem...seal is properly installed, ensure that there is no free play between the seal body and the wire. Verify and record the serial number. During post

  6. Fog seal guidelines.

    DOT National Transportation Integrated Search

    2003-10-01

    Fog seals are a method of adding asphalt to an existing pavement surface to improve sealing or waterproofing, prevent further stone loss by holding aggregate in place, or simply improve the surface appearance. However, inappropriate use can result in...

  7. Performance Evaluations of Ceramic Wafer Seals

    NASA Technical Reports Server (NTRS)

    Dunlap, Patrick H., Jr.; DeMange, Jeffrey J.; Steinetz, Bruce M.

    2006-01-01

    Future hypersonic vehicles will require high temperature, dynamic seals in advanced ramjet/scramjet engines and on the vehicle airframe to seal the perimeters of movable panels, flaps, and doors. Seal temperatures in these locations can exceed 2000 F, especially when the seals are in contact with hot ceramic matrix composite sealing surfaces. NASA Glenn Research Center is developing advanced ceramic wafer seals to meet the needs of these applications. High temperature scrub tests performed between silicon nitride wafers and carbon-silicon carbide rub surfaces revealed high friction forces and evidence of material transfer from the rub surfaces to the wafer seals. Stickage between adjacent wafers was also observed after testing. Several design changes to the wafer seals were evaluated as possible solutions to these concerns. Wafers with recessed sides were evaluated as a potential means of reducing friction between adjacent wafers. Alternative wafer materials are also being considered as a means of reducing friction between the seals and their sealing surfaces and because the baseline silicon nitride wafer material (AS800) is no longer commercially available.

  8. Soil gas geochemistry in relation to eruptive fissures on Timanfaya volcano, Lanzarote Island (Canary Islands, Spain)

    NASA Astrophysics Data System (ADS)

    Padrón, Eleazar; Padilla, Germán; Hernández, Pedro A.; Pérez, Nemesio M.; Calvo, David; Nolasco, Dácil; Barrancos, José; Melián, Gladys V.; Dionis, Samara; Rodríguez, Fátima

    2013-01-01

    We report herein the first results of an extensive soil gas survey performed on Timanfaya volcano on May 2011. Soil gas composition at Timanfaya volcano indicates a main atmospheric source, slightly enriched in CO2 and He. Soil CO2 concentration showed a very slight deep contribution of the Timanfaya volcanic system, with no clear relation to the main eruptive fissures of the studied area. The existence of soil helium enrichments in Timanfaya indicates a shallow degassing of crustal helium and other possible deeper sources probably form cooling magma bodies at depth. The main soil helium enrichments were observed in good agreement with the main eruptive fissures of the 1730-36 eruption, with the highest values located at those areas with a higher density of recent eruptive centers, indicating an important structural control for the leakage of helium at Timanfaya volcano. Atmospheric air slightly polluted by deep-seated helium emissions, CO2 degassed from a cooling magma body, and biogenic CO2, might be the most plausible explanation for the existence of soil gas. Helium is a deep-seated gas, exhibiting important emission rates along the main eruptive fissure of the 1730-36 eruption of Timanfaya volcano.

  9. Compliant high temperature seals for dissimilar materials

    DOEpatents

    Rynders, Steven Walton; Minford, Eric; Tressler, Richard Ernest; Taylor, Dale M.

    2001-01-01

    A high temperature, gas-tight seal is formed by utilizing one or more compliant metallic toroidal ring sealing elements, where the applied pressure serves to activate the seal, thus improving the quality of the seal. The compliant nature of the sealing element compensates for differences in thermal expansion between the materials to be sealed, and is particularly useful in sealing a metallic member and a ceramic tube art elevated temperatures. The performance of the seal may be improved by coating the sealing element with a soft or flowable coating such as silver or gold and/or by backing the sealing element with a bed of fine powder. The material of the sealing element is chosen such that the element responds to stress elastically, even at elevated temperatures, permitting the seal to operate through multiple thermal cycles.

  10. Brush seals for turbine engine fuel conservation

    NASA Astrophysics Data System (ADS)

    Sousa, Mike

    1994-07-01

    The program objective is to demonstrate brush seals for replacing labyrinth seals in turboprop engines. The approach taken was to design and procure brush seals with assistance from Sealol, modify and instrument an existing T407 low pressure turbine test rig, replace inner balance piston and outer balance piston labyrinth seals with brush seals, conduct cyclic tests to evaluate seal leakage at operating pressures and temperatures, and evaluate effect of seal pack width and rotor eccentricity. Results are presented in viewgraph format and show that brush seals offer performance advantages over labyrinth seals.

  11. Seals and Scrolls.

    ERIC Educational Resources Information Center

    Macaulay, Sara Grove

    2000-01-01

    Describes an art unit in which students sculpt a signature seal out of clay and use Chinese brush painting techniques to paint a scroll. Discusses the seal and its historical use in China. Lists materials needed and explains the procedure. (CMK)

  12. 39 CFR 2.4 - Seal.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 39 Postal Service 1 2011-07-01 2011-07-01 false Seal. 2.4 Section 2.4 Postal Service UNITED STATES... (ARTICLE II) § 2.4 Seal. (a) The Seal of the Postal Service is filed by the Board in the Office of the Secretary of State, and is required by 39 U.S.C. 207 to be judicially noticed. The Seal shall be in the...

  13. 39 CFR 2.4 - Seal.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Seal. 2.4 Section 2.4 Postal Service UNITED STATES... (ARTICLE II) § 2.4 Seal. (a) The Seal of the Postal Service is filed by the Board in the Office of the Secretary of State, and is required by 39 U.S.C. 207 to be judicially noticed. The Seal shall be in the...

  14. Self-acting seals for helicopter engines

    NASA Technical Reports Server (NTRS)

    Lynwander, P.

    1975-01-01

    An experimental evaluation was conducted with NASA-designed self-acting face and circumferential seals for use in the main shaft positions of advanced gas turbine engines. The seals featured Rayleigh step pads (self-acting geometry) for lift augmentation. The tested seals incorporated design improvements over previous self-acting configurations. Self-acting face seals were tested to speeds of 214 m/s (700 ft/sec, 63700 rpm), air pressures of 216.8 N/sq cm abs (314.7 psia), and air temperatures of 688K (778 F). Self-acting circumferential seals were tested to speeds of 183 m/s (600 ft/sec, 47700 rpm), air pressures of 61.8 N/sq cm abs (89.7 psia), and air temperatures of 711 K (820 F). Self-acting face-seals are capable of operating at conditions exceeding conventional seal capability. The limit on speed capability was found to be the flatness of the seal-seat. The self-acting circumferential seal design tested requires further development for use in advanced engines.

  15. Further Investigations of Hypersonic Engine Seals

    NASA Technical Reports Server (NTRS)

    Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; DeMange, Jeffrey J.

    2004-01-01

    Durable, flexible sliding seals are required in advanced hypersonic engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures of 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA's Glenn Research Center is developing advanced seals and preloading devices to overcome these shortfalls. An advanced ceramic wafer seal design and two silicon nitride compression spring designs were evaluated in a series of compression, scrub, and flow tests. Silicon nitride wafer seals survived 2000 in. (50.8 m) of scrubbing at 2000 F against a silicon carbide rub surface with no chips or signs of damage. Flow rates measured for the wafers before and after scrubbing were almost identical and were up to 32 times lower than those recorded for the best braided rope seal flow blockers. Silicon nitride compression springs showed promise conceptually as potential seal preload devices to help maintain seal resiliency.

  16. Detection of seal contamination in heat-sealed food packaging based on active infrared thermography

    NASA Astrophysics Data System (ADS)

    D'huys, Karlien; Saeys, Wouter; De Ketelaere, Bart

    2015-05-01

    In the food industry packaging is often applied to protect the product from the environment, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the material used and the closure (seal). The material is selected based on the specific needs of the food product to be wrapped. However, proper closure of the package is often harder to achieve. One problem possibly jeopardizing seal quality is the presence of food particles between the seal. Seal contamination can cause a decreased seal strength and thus an increased packaging failure risk. It can also trigger the formation of microchannels through which air and microorganisms can enter and spoil the enclosed food. Therefore, early detection and removal of seal-contaminated packages from the production chain is essential. In this work, a pulsed-type active thermography method using the heat of the sealing bars as an excitation source was studied for detecting seal contamination. The cooling profile of contaminated seals was recorded. The detection performance of four processing methods (based on a single frame, a fit of the cooling profile, pulsed phase thermography and a matched filter) was compared. High resolution digital images served as a reference to quantify contamination. The lowest detection limit (equivalent diameter of 0.63 mm) and the lowest processing time (0.42 s per sample) were obtained for the method based on a single frame. Presumably, practical limitations in the recording stage prevented the added value of active thermography to be fully reflected in this application.

  17. Rice fissure resistance QTLs from ‘Saber’ complement those from ‘Cypress’

    USDA-ARS?s Scientific Manuscript database

    The economic value of broken rice is about half that of whole milled rice, so one goal of producers, millers, and rice breeders is to reduce grain breakage during the dehusking and milling processes. One of the primary causes of rice breakage is fissuring, or cracking, of the rice before it enters ...

  18. Neuromuscular dentistry: Occlusal diseases and posture.

    PubMed

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture.

  19. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, J.V.; Novak, R.F.; McBride, J.R.

    1991-08-27

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system. 11 figures.

  20. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, John V.; Novak, Robert F.; McBride, James R.

    1991-01-01

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system.

  1. Shaft Seal Compensates for Cold Flow

    NASA Technical Reports Server (NTRS)

    Myers, W. N.; Hein, L. A.

    1985-01-01

    Seal components easy to install. Ring seal for rotating or reciprocating shafts spring-loaded to compensate for slow yielding (cold flow) of sealing material. New seal relatively easy to install because components preassembled, then installed in one piece.

  2. Film riding seals for rotary machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bidkar, Rahul Anil; Sarawate, Neelesh Nandkumar; Wolfe, Christopher Edward

    A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further,more » the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.« less

  3. Army Research Concerns in Engine Sealing

    NASA Technical Reports Server (NTRS)

    Bill, Robert C.

    1991-01-01

    The Army Propulsion Directorate is primarily concerned with small engine technology, where sealing performance is most critical. Tip leakage and secondary flow losses have a much greater performance impact on small engine aero-components than on large engines. A brief survey and critique of presently employed sealing concepts is presented. Some recent new research thrusts that show promise for substantial improvement are discussed. An especially promising approach for small engine applications is brush seals. Brush seal concepts are being considered for outer air seal and secondary airflow system seal locations.

  4. Monolithic LTCC seal frame and lid

    DOEpatents

    Krueger, Daniel S.; Peterson, Kenneth A.; Stockdale, Dave; Duncan, James Brent; Riggs, Bristen

    2016-06-21

    A method for forming a monolithic seal frame and lid for use with a substrate and electronic circuitry comprises the steps of forming a mandrel from a ceramic and glass based material, forming a seal frame and lid block from a ceramic and glass based material, creating a seal frame and lid by forming a compartment and a plurality of sidewalls in the seal frame and lid block, placing the seal frame and lid on the mandrel such that the mandrel fits within the compartment, and cofiring the seal frame and lid block.

  5. Low-Torque Seal Development

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Borowski, Richard

    2009-01-01

    The EcoTurn Class K production prototypes have passed all AAR qualification tests and received conditional approval. The accelerated life test on the second set of seals is in progress. Due to the performance of the first set, no problems are expected.The seal has demonstrated superior performance over the HDL seal in the test lab with virtually zero torque and excellent contamination exclusion and grease retention.

  6. Status of Seal Development at Technetics

    NASA Astrophysics Data System (ADS)

    Chappel, Doug

    2002-10-01

    Technetics has recently reported results for blade tip seal rub characteristics. Expanding on this work, Technetics will share rub characteristics for knife edge abradable seal systems typical of those found at vane inner air seal and shaft seal locations.

  7. Low-leakage and low-instability labyrinth seal

    NASA Technical Reports Server (NTRS)

    Rhode, David L. (Inventor)

    1997-01-01

    Improved labyrinth seal designs are disclosed. The present invention relates to labyrinth seal systems with selected sealing surfaces and seal geometry to optimize flow deflection and produce maximum turbulent action. Optimum seal performance is generally accomplished by providing sealing surfaces and fluid cavities formed to dissipate fluid energy as a function of the geometry of the sealing surfaces along with the position and size of the fluid cavities formed between members of the labyrinth seal system. Improved convex surfaces, annular flow reversal grooves, flow deflection blocks and rough, machined surfaces cooperate to enhance the performance of the labyrinth seal systems. For some labyrinth seal systems a mid-cavity throttle and either rigid teeth or flexible spring teeth may be included.

  8. Development of helicopter engine seals

    NASA Technical Reports Server (NTRS)

    Lynwander, P.

    1973-01-01

    An experimental evaluation of main shaft seals for helicopter gas turbine engines was conducted with shaft speeds to 213 m/s(700 ft/sec), air pressures to 148 N/sq cm (215 psia), and air temperatures to 645 K (675 F). Gas leakage test results indicate that conventional seals will not be satisfactory for high-pressure sealing because of excessive leakage. The self-acting face seal, however, had significantly lower leakage and operated with insignificant wear during a 150-hour endurance test at sliding speeds to 145 m/s (475 ft/sec), air pressures to 124 N/sq cm (180 psia), and air temperatures to 408 K (275 F). Wear measurements indicate that noncontact operation was achieved at shaft speeds of 43,000 rpm. Evaluation of the self-acting circumferential seal was inconclusive because of seal dimensional variations.

  9. Integrated seal for high-temperature electrochemical device

    DOEpatents

    Tucker, Michael C; Jacobson, Craig P

    2013-07-16

    The present invention provides electrochemical device structures having integrated seals, and methods of fabricating them. According to various embodiments the structures include a thin, supported electrolyte film with the electrolyte sealed to the support. The perimeter of the support is self-sealed during fabrication. The perimeter can then be independently sealed to a manifold or other device, e.g., via an external seal. According to various embodiments, the external seal does not contact the electrolyte, thereby eliminating the restrictions on the sealing method and materials imposed by sealing against the electrolyte.

  10. Development of braided rope engine seals

    NASA Technical Reports Server (NTRS)

    Ko, Frank K.; Cai, Zhong; Mutharasan, Rajakkannu; Steinetz, Bruce M.

    1994-01-01

    In this study, after reviewing current seal design concepts, the potential of textile structures for seal design is examined from the material, structural, and fabrication points of view. Braided structures are identified as potential candidates for hypersonic seal structures because of their conformability and design flexibility. A large family of braided structures using 2-D and 3-D architecture can be designed using well established methods to produce a wide range of braiding yarn orientation for wear resistance as well as seal porosity control. As a first demonstration of the approach, 2-D braided fiberglass seals were fabricated according to a factorial design experiment by varying braiding angles, fractional longitudinal fibers, and preload pressure levels. Factorial diagrams and response surfaces were constructed to elucidate the inter-relationship of the braiding parameters as well as the effect of preload pressures on leakage resistance of the seal. It was found that seal resistance is a strong function of fractional longitudinal fiber content. As braiding angle increases, seal leakage resistance increases, especially at high preload pressures and in seals having high proportion of longitudinal fibers.

  11. Biomechanics of occlusion--implications for oral rehabilitation.

    PubMed

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. © 2015 John Wiley & Sons Ltd.

  12. Dental occlusion and temporomandibular disorders.

    PubMed

    Stone, J Caitlin; Hannah, Andrew; Nagar, Nathan

    2017-10-27

    Data sourcesMedline, Scopus and Google Scholar.Study selectionTwo reviewers selected studies independently. English language clinical studies assessing the association between temporomandibular disorders (TMD) and features of dental occlusion were considered.Data extraction and synthesisStudy quality was assessed based on the Newcastle-Ottawa Scale (NOS) and a narrative synthesis was presented.ResultsIn all 25 studies (17 case-control, eight comparative) were included. Overall there was a high variability between occlusal features and TMD diagnosis. Findings were consistent with a lack of clinically relevant association between TMD and dental occlusion. Only two studies were associated with TMD in the majority (≥50%) of single variable analyses in patient populations. Only mediotrusive interferences are associated with TMD in the majority of multiple variable analyses.ConclusionsThe findings support the absence of a disease-specific association, there is no ground to hypothesise a major role for dental occlusion in the pathophysiology of TMDs. Dental clinicians are thus encouraged to move forward and abandon the old-fashioned gnathological paradig.

  13. Pressure Seal For Frequently Opened Hatch

    NASA Technical Reports Server (NTRS)

    Kennedy, Steven E.; Kramer, Joel M.

    1994-01-01

    Pressure-assisted seal for frequently opened hatch includes two sealing rings retained positively so not pulled out during opening. Seal makes contact with hatch well before hatch starts to squeeze rings extending distance over which seal becomes engaged. Improvements include more-secure mounting, redundancy, and better initial sealing action. Also minimizes loss of gas during closure by deflecting inward and closing gap. This action helps differential pressure to force hatch closed.

  14. Conventional occlusion versus pharmacologic penalization for amblyopia.

    PubMed

    Li, Tianjing; Shotton, Kate

    2009-10-07

    Amblyopia is defined as defective visual acuity in one or both eyes without demonstrable abnormality of the visual pathway, and is not immediately resolved by wearing glasses. To assess the effectiveness and safety of conventional occlusion versus atropine penalization for amblyopia. We searched CENTRAL, MEDLINE, EMBASE, LILACS, the WHO International Clinical Trials Registry Platform, preference lists, science citation index and ongoing trials up to June 2009. We included randomized/quasi-randomized controlled trials comparing conventional occlusion to atropine penalization for amblyopia. Two authors independently screened abstracts and full text articles, abstracted data, and assessed the risk of bias. Three trials with a total of 525 amblyopic eyes were included. One trial was assessed as having a low risk of bias among these three trials, and one was assessed as having a high risk of bias.Evidence from three trials suggests atropine penalization is as effective as conventional occlusion. One trial found similar improvement in vision at six and 24 months. At six months, visual acuity in the amblyopic eye improved from baseline 3.16 lines in the occlusion and 2.84 lines in the atropine group (mean difference 0.034 logMAR; 95% confidence interval (CI) 0.005 to 0.064 logMAR). At 24 months, additional improvement was seen in both groups; but there continued to be no meaningful difference (mean difference 0.01 logMAR; 95% CI -0.02 to 0.04 logMAR). The second trial reported atropine to be more effective than occlusion. At six months, visual acuity improved 1.8 lines in the patching group and 3.4 lines in the atropine penalization group, and was in favor of atropine (mean difference -0.16 logMAR; 95% CI -0.23 to -0.09 logMAR). Different occlusion modalities were used in these two trials. The third trial had inherent methodological flaws and limited inference could be drawn.No difference in ocular alignment, stereo acuity and sound eye visual acuity between occlusion and

  15. Tamper indicating seal

    DOEpatents

    Romero, Juan A [Albuquerque, NM; Walker, Charles A [Albuquerque, NM; Blair, Dianna S [Albuquerque, NM; Bodmer, Connie C [Albuquerque, NM

    2012-05-29

    Seals have a flexible wire that can be looped through a hasp-like device. The seals include a body having a recess, a plug insertable into the recess and a snap ring for fastening the plug to the body. The plug and/or body can have access holes for inserting the wire into the recess. "Teeth" on the outer diameter and through-holes through the thickness of the snap ring allow for passing the ends of the flexible wire from the recess through the snap ring. The ends of the wire can be folded back over the snap ring and into engagement with the teeth. Assembly of the seal causes the ends of the wire to be securely fastened between the teeth of the snap ring and the sidewall of the recess. Seals can include a plug and/or body made of a frangible material such as glass, ceramic, glass-ceramic or brittle polymer.

  16. Sealing properties of a self-etching primer system to normal caries-affected and caries-infected dentin.

    PubMed

    Lee, Kwang-Won; Son, H-H; Yoshiyama, Masatoshi; Tay, Franklin R; Carvalho, Ricardo M; Pashley, David H

    2003-09-01

    To compare the ability of an experimental antibacterial self-etching primer adhesive system to seal exposure sites in normal, caries-affected and caries-infected human dentin. 30 extracted human third molars were used within 1 month of extraction. 10 intact normal teeth comprised the normal group. 20 teeth with occlusal caries that radiographically extended halfway to the pulp were excavated using caries-detector solution (CDS) and a #4 round carbide bur in a slowspeed handpiece. Half of those teeth were fully excavated free of CDS-stained material without exposing the pulp, and were designated as the caries-affected dentin group. The remaining 10 teeth were excavated as close to the pulp as possible without obtaining an exposure, but whose dentin continued to stain red with CDS; this group was designated as the caries-infected dentin group. The remaining dentin thickness in all of the specimens in the other two groups was then reduced to the same extent as the caries-infected group. Direct exposures of the pulp chamber were made with a 1/4 round bur in the normal dentin or a 25 gauge needle in the other two groups. After measuring the fluid flow through the exposure, the sites were then sealed with an experimental antibacterial fluoride-containing self-etching primer adhesive systems (ABF). Fluid conductance was remeasured every week for 16 weeks. The fluid conductance through the exposure fell 99% in all groups following resin sealing. The seals of normal and caries-affected dentin remained relatively stable over the 16 weeks, while the seals of caries-infected dentin gradually deteriorated, reaching significance at 8 weeks. TEM examination revealed very thin (ca. 0.5 mm) hybrid layers in normal dentin, 3-4 microm thick hybrid layers in caries-affected dentin and 40 microm thick hybrid layers in caries-infected dentin. The tubules of caries-infected dentin were enlarged and filled with bacteria. Resin tags passed around these bacteria in the top 20-40 microm

  17. Rotary seal with improved film distribution

    DOEpatents

    Dietle, Lannie Laroy; Schroeder, John Erick

    2013-10-08

    The present invention is a generally circular rotary seal that establishes sealing between relatively rotatable machine components for lubricant retention and environmental exclusion, and incorporates seal geometry that interacts with the lubricant during relative rotation to distribute a lubricant film within the dynamic sealing interface. The features of a variable inlet size, a variable dynamic lip flank slope, and a reduction in the magnitude and circumferentially oriented portion of the lubricant side interfacial contact pressure zone at the narrowest part of the lip, individually or in combination thereof, serve to maximize interfacial lubrication in severe operating conditions, and also serve to minimize lubricant shear area, seal torque, seal volume, and wear, while ensuring retrofitability into the seal grooves of existing equipment.

  18. Rotary seal with improved film distribution

    DOEpatents

    Dietle, Lannie Laroy; Schroeder, John Erick

    2015-09-01

    The present invention is a generally circular rotary seal that establishes sealing between relatively rotatable machine components for lubricant retention and environmental exclusion, and incorporates seal geometry that interacts with the lubricant during relative rotation to distribute a lubricant film within the dynamic sealing interface. The features of a variable inlet size, a variable dynamic lip flank slope, and a reduction in the magnitude and circumferentially oriented portion of the lubricant side interfacial contact pressure zone at the narrowest part of the lip, individually or in combination thereof, serve to maximize interfacial lubrication in severe operating conditions, and also serve to minimize lubricant shear area, seal torque, seal volume, and wear, while ensuring retrofitability into the seal grooves of existing equipment.

  19. Method for producing a fuel cell manifold seal

    DOEpatents

    Grevstad, Paul E.; Johnson, Carl K.; Mientek, Anthony P.

    1982-01-01

    A manifold-to-stack seal and sealing method for fuel cell stacks. This seal system solves the problem of maintaining a low leak rate manifold seal as the fuel cell stack undergoes compressive creep. The seal system eliminates the problem of the manifold-to-stack seal sliding against the rough stack surface as the stack becomes shorter because of cell creep, which relative motion destroys the seal. The seal system described herein utilizes a polymer seal frame firmly clamped between the manifold and the stack such that the seal frame moves with the stack. Thus, as the stack creeps, the seal frame creeps with it, and there is no sliding at the rough, tough to seal, stack-to-seal frame interface. Here the sliding is on a smooth easy to seal location between the seal frame and the manifold.

  20. Seals Having Textured Portions for Protection in Space Environments

    NASA Technical Reports Server (NTRS)

    Daniels, Christopher (Inventor); Garafolo, Nicholas (Inventor)

    2016-01-01

    A sealing construct for a space environment includes a seal-bearing object, a seal on the seal-bearing object, and a seal-engaging object. The seal includes a seal body having a sealing surface, and a textured pattern at the sealing surface, the textured pattern defining at least one shaded channel surface. The seal-engaging object is selectively engaged with the seal-bearing object through the seal. The seal-engaging object has a sealing surface, wherein, when the seal-engaging object is selectively engaged with the seal-bearing object, the sealing surface of the seal-engaging object engages the sealing surface of the seal, and the seal is compressed between the seal-bearing object and the seal-engaging object such that at least one shaded channel surface engages the sealing surface of the seal-engaging object.

  1. [Banana peel: a possible source of infection in the treatment of nipple fissures].

    PubMed

    Novak, Franz Reis; de Almeida, João Aprígio Guerra; de Souza e Silva, Rosana

    2003-01-01

    To study the microbiology of banana peel being sold in the city of Rio de Janeiro, in an attempt to determine the possibility that the peel may represent a source of infection for women who use it to treat nipple fissures. The following microorganisms were studied in 20 banana peel samples: mesophiles, total coliforms, fecal coliforms, Pseudomonas aeruginosa, lipolytic and proteolytic microorganisms, molds and yeasts, lactic bacteria, and coagulase-positive staphylococcus. The microbiological analyses revealed the occurrence of several typical groups of microorganisms, with the following distribution of positive results being detected in banana peel samples: mesophiles, 100%; total coliforms, 20%; coagulase-positive staphylococcus, 25%; molds and yeasts, 30%; proteolytic microorganisms, 70%; lipolytic microorganisms, 30%, and lactic bacteria, 95%. Fecal coliforms and Pseudomonas aeruginosa were not isolated. The results show the presence of potentially pathogenic microorganisms in levels which could compromise the microbiological quality of the banana peel. Its use for the treatment of nipple fissures can initiate an infectious process.

  2. Development of a Brush Seals Program Leading to Ceramic Brush Seals

    NASA Technical Reports Server (NTRS)

    Hendricks, Robert C.; Flower, Ralph; Howe, Harold

    1994-01-01

    Some events of a U.S. Army/NASA Lewis Research Center brush seals program are reviewed, and the development of ceramic brush seals is described. Some preliminary room-temperature flow data are given, and the results of testing metallic brushes in cryogenic nitrogen are discussed.

  3. A Novel Approach to Model Earth Fissure Caused by Extensive Aquifer Exploitation and its Application to the Wuxi Case, China

    NASA Astrophysics Data System (ADS)

    Ye, Shujun; Franceschini, Andrea; Zhang, Yan; Janna, Carlo; Gong, Xulong; Yu, Jun; Teatini, Pietro

    2018-03-01

    Initially observed in the semiarid basins of southwestern USA, earth fissures due to aquifer over-exploitation are presently threatening a large number of subsiding basins in various countries worldwide. Different mechanics have been proposed to explain this process, such as differential compaction, horizontal movements, and fault reactivation. Numerical modeling and prediction of this major geohazard caused by overuse of groundwater resources are challenging because of two main requirements: shifting from the classical continuous to discontinuous geomechanics and incorporating two-dimensional features (the earth fissures) into large three-dimensional (3-D) modeling domain (the subsiding basin). In this work, we proposed a novel modeling approach to simulate earth fissure generation and propagation in 3-D complex geological settings. A nested two-scale approach associated with an original nonlinear elastoplastic finite element/interface element simulator allows modeling the mechanics of earth discontinuities, in terms of both sliding and opening. The model is applied on a case study in Wuxi, China, where groundwater pumping between 1985 and 2004 has caused land subsidence larger than 2 m. The model outcomes highlight that the presence of a shallow (˜80 m deep) bedrock ridge crossing the Yangtze River delta is the key factor triggering the earth fissure development in this area. Bending of the alluvial deposits around the ridge tip and shear stress due to the uneven piezometric change and asymmetrical shape of the bedrock have caused the earth fissure to onset at the land surface and propagate downward to a maximum depth of about 20-30 m. Maximum sliding and opening are computed in the range of 10-40 cm, in agreement with the order of magnitude estimated in the field.

  4. The length of pre-existing fissures effects on the mechanical properties of cracked red sandstone and strength design in engineering.

    PubMed

    Wu, Jiangyu; Feng, Meimei; Yu, Bangyong; Han, Guansheng

    2018-01-01

    It is important to study the mechanical properties of cracked rock to understand the engineering behavior of cracked rock mass. Consequently, the influence of the length of pre-existing fissures on the strength, deformation, acoustic emission (AE) and failure characteristics of cracked rock specimen was analyzed, and the optimal selection of strength parameter in engineering design was discussed. The results show that the strength parameters (stress of dilatancy onset and uniaxial compressive strength) and deformation parameters (axial strain and circumferential strain at dilatancy onset and peak point) of cracked rock specimen decrease with the increase of the number of pre-existing fissures, and the relations which can use the negative exponential function to fit. Compared with the intact rock specimens, the different degrees of stress drop phenomena were produced in the process of cracked rock specimens when the stress exceeds the dilatancy onset. At this moment, the cracked rock specimens with the existence of stress drop are not instantaneous failure, but the circumferential strain, volumetric strain and AE signals increase burstingly. And the yield platform was presented in the cracked rock specimen with the length of pre-existing fissure more than 23mm, the yield failure was gradually conducted around the inner tip of pre-existing fissure, the development of original fissures and new cracks was evolved fully in rock. However, the time of dilatancy onset is always ahead of the the time of that point with the existence of stress drop. It indicates that the stress of dilatancy onset can be as the parameter of strength design in rock engineering, which can effectively prevent the large deformation of rock. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Necrotizing Fasciitis of the Periorbital Region Complicated by Combined Central Retinal Artery Occlusion, Central Retinal Vein Occlusion, and Posterior Ciliary Occlusion.

    PubMed

    Sultan, Harris; Malik, Amina; Li, Helen K; Chévez-Barrios, Patricia; Lee, Andrew G

    A 50 year-old man on immunosuppressive agents presented with left eye vision loss, periorbital swelling, pain, and ophthalmoplegia. The patient was clinically found to have a central retinal artery and vein occlusion. A CT scan was performed which demonstrated intraorbital fat stranding, however the patient lacked sinus disease. The etiology of the orbital infection was held in question. The area was debrided in the operating room, and the specimen demonstrated group A streptococcal species consistent with necrotizing fasciitis. Periorbital necrotizing fasciitis should be suspected in patients with rapidly progressive orbital symptoms without sinus disease as lack of surgical intervention can result in poor outcomes. The unusual aspect to this case is the mechanism of vision loss, as the authors hypothesize that there was vascular infiltration of the infection resulting in the central retinal artery occlusion and central retinal vein occlusion which have not been previously reported secondary to necrotizing fasciitis of the orbit.

  6. Seal for sodium sulfur battery

    DOEpatents

    Topouzian, Armenag; Minck, Robert W.; Williams, William J.

    1980-01-01

    This invention is directed to a seal for a sodium sulfur battery in which the sealing is accomplished by a radial compression seal made on a ceramic component of the battery which separates an anode compartment from a cathode compartment of the battery.

  7. 7 CFR 29.34 - Sample seal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sample seal. 29.34 Section 29.34 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Definitions § 29.34 Sample seal. A seal approved by the Director for sealing official...

  8. 7 CFR 29.34 - Sample seal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sample seal. 29.34 Section 29.34 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Definitions § 29.34 Sample seal. A seal approved by the Director for sealing official...

  9. Neuromuscular dentistry: Occlusal diseases and posture

    PubMed Central

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K.

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture. PMID:25737904

  10. 19 CFR 113.25 - Seals.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BONDS... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... requires its acts to be evidenced by its corporate seal, such seal is required. ...

  11. 19 CFR 113.25 - Seals.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BONDS... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... requires its acts to be evidenced by its corporate seal, such seal is required. ...

  12. 19 CFR 113.25 - Seals.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BONDS... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... requires its acts to be evidenced by its corporate seal, such seal is required. ...

  13. 19 CFR 113.25 - Seals.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BONDS... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... requires its acts to be evidenced by its corporate seal, such seal is required. ...

  14. 19 CFR 113.25 - Seals.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CUSTOMS BONDS... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... requires its acts to be evidenced by its corporate seal, such seal is required. ...

  15. 7 CFR 29.35 - Lot seal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Lot seal. 29.35 Section 29.35 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Definitions § 29.35 Lot seal. A seal approved by the Director for sealing lots of...

  16. 7 CFR 29.35 - Lot seal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Lot seal. 29.35 Section 29.35 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Definitions § 29.35 Lot seal. A seal approved by the Director for sealing lots of...

  17. Liquid Annular Seal Research

    NASA Technical Reports Server (NTRS)

    Palazzolo, Alan B.; Venkataraman, Balaji; Padavala, Sathya S.; Ryan, Steve; Vallely, Pat; Funston, Kerry

    1996-01-01

    This paper highlights the accomplishments on a joint effort between NASA - Marshall Space Flight Center and Texas A and M University to develop accurate seal analysis software for use in rocket turbopump design, design audits and trouble shooting. Results for arbitrary clearance profile, transient simulation, thermal effects solution and flexible seal wall model are presented. A new solution for eccentric seals based on cubic spline interpolation and ordinary differential equation integration is also presented.

  18. Seals Flow Code Development

    NASA Technical Reports Server (NTRS)

    1991-01-01

    In recognition of a deficiency in the current modeling capability for seals, an effort was established by NASA to develop verified computational fluid dynamic concepts, codes, and analyses for seals. The objectives were to develop advanced concepts for the design and analysis of seals, to effectively disseminate the information to potential users by way of annual workshops, and to provide experimental verification for the models and codes under a wide range of operating conditions.

  19. Effect of artificial aging on the bond durability of fissure sealants.

    PubMed

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p < 0.05). Longer thermocycling (10,000 cycles) resulted in more decreases in µTBS for group PEL and PPC, while the strength of the UX group remained relatively unchanged. After thermocycling, considerable silver penetration could be seen at the sealant/enamel interface of the EL group in micro-CT images. The etch-and-rinse procedure for sealant application promotes higher bond strength under artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  20. Probe insertion apparatus with inflatable seal

    NASA Technical Reports Server (NTRS)

    Trimarchi, Paul A. (Inventor)

    1990-01-01

    A sealing apparatus is disclosed for inserting a probe into a pressure vessel having an elongated opening includes a pair of resiliently deformable seals opposingly disposed in sealing engagement with each other. A retainer is connected to the pressure vessel around the elongated opening and holds the pair of seals rigidly to the pressure vessel. A wedge is engageable with the pair of seals and carries the probe, for longitudinally translating the probe in pressure vessel.

  1. Self-acting and hydrodynamic shaft seals

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P.

    1973-01-01

    Self-acting and hydrodynamic seals are described. The analytical procedures are outlined for obtaining a seal force balance and the operating film thickness. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis revealed three different vibration modes. Proposed applications of self-acting seals in gas turbine engines and in rocket vehicle turbopumps are described. Also experimental data on self-acting face seals operating under simulated gas turbine conditions are given; these data show the feasibility of operating the seal at conditions of 345 newtons per square centimeter (500 psi) and 152 meters per second (500 ft/sec) sliding speed.

  2. Chronic anal fissure: morphometric analysis of the anal canal at 3.0 Tesla MR imaging.

    PubMed

    Erden, Ayşe; Peker, Elif; Gençtürk, Zeynep Bıyıklı

    2017-02-01

    OBJECTıVE: To compare the morphometric data relating to the muscular structures of the anal canal, in patients with chronic anal fissure and in control group, examined at a 3.0 Tesla MR system. Forty-seven consecutive patients with chronic anal fissure and randomly selected 40 patients who had no claims for perianal disease during their life time were included in the study. T2-weighted sagittal, high-resolution (HR) T2-weighted, and contrast-enhanced fat-suppressed T1-weighted oblique axial and oblique coronal images were retrospectively analyzed by two observers in consensus. Thickness of sphincteric muscles, anal canal length, anorectal angle, thickness of anococcygeal ligament, depth of Minor triangle, width between subcutaneous sphincters, vascularity of posterior commissure, visibility of posterosuperior projection of external sphincter, and angle between the distal anal canal and posterosuperior projection of external sphincter (H angle) in patients and in controls were compared and analyzed using t test, Mann-Whitney U test, and Spearman correlation. The patients with chronic anal fissure had longer anal canal (51.50 mm ± 0.91 vs. 44.11 mm ± 0.71; p = 0.000), thicker internal anal sphincter muscle at mid-anal level (4.18 ± 0.15 vs. 3.39 ± 0.07; p = 0.007), and wider space between subcutaneous external sphincters (11.39 ± 0.50 vs. 6.89 ± 0.22; p = 0.000). In patients, there was a positive correlation between H angle and external sphincter thickness at proximal (r = 0.347; p = 0.021), middle (r = 0427; p = 0.000), and distal (r = 0.518; p = 0.000)) levels of the anal canal. CONCLUSıON: 3.0 Tesla MR imaging provides detailed information about the morphometric changes in the anal sphincter muscles in patients with chronic anal fissure.

  3. Overview of LIDS Docking and Berthing System Seals

    NASA Technical Reports Server (NTRS)

    Daniels, Christopher C.; Dunlap, Patrick H., Jr.; deGroh, Henry C., III; Steinetz, Bruce M.; Oswald, Jay J.; Smith, Ian

    2007-01-01

    This viewgraph presentation describes the Low Impact Docking System (LIDS) docking and berthing system seals. The contents include: 1) Description of the Application: Low Impact Docking System (LIDS); 2) LIDS Seal Locations: Vehicle Undocked (Hatch Closed); 3) LIDS Seal Locations: Mechanical Pass Thru; 4) LIDS Seal Locations: Electrical and Pyro Connectors; 5) LIDS Seal Locations: Vehicle Docked (Hatches Open); 6) LIDS Seal Locations: Main Interface Seal; 7) Main Interface Seal Challenges and Specifications; 8) Approach; 9) Seal Concepts Under Development/Evaluation; 10) Elastomer Material Evaluations; 11) Evaluation of Relevant Seal Properties; 12) Medium-Scale (12") Gask-O-Seal Compression Tests; 13) Medium-Scale Compression Results; 14) Adhesion Forces of Elliptical Top Gask-o-seals; 15) Medium-Scale Seals; 16) Medium-Scale Leakage Results: Effect of Configuration; 17) Full Scale LIDS Seal Test Rig Development; 18) Materials International Space Station Experiment (MISSE 6A and 6B); and 19) Schedule.

  4. 30 CFR 75.339 - Seals records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Seals records. 75.339 Section 75.339 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.339 Seals records. (a) The table entitled “Seal.... Table—§ 75.339(a) Seal Recordkeeping Requirements Record Section reference Retention time (1) Approved...

  5. 39 CFR 3002.3 - Official seal.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Official seal. 3002.3 Section 3002.3 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL ORGANIZATION § 3002.3 Official seal. (a) Authority. The Seal described in this section is hereby established as the official seal of the Postal Rate Commission...

  6. 39 CFR 3002.3 - Official seal.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 39 Postal Service 1 2011-07-01 2011-07-01 false Official seal. 3002.3 Section 3002.3 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL ORGANIZATION § 3002.3 Official seal. (a) Authority. The Seal described in this section is hereby established as the official seal of the Postal Rate Commission...

  7. 30 CFR 75.339 - Seals records.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Seals records. 75.339 Section 75.339 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.339 Seals records. (a) The table entitled “Seal.... Table—§ 75.339(a) Seal Recordkeeping Requirements Record Section reference Retention time (1) Approved...

  8. Airfoil seal system for gas turbine engine

    DOEpatents

    None, None

    2013-06-25

    A turbine airfoil seal system of a turbine engine having a seal base with a plurality of seal strips extending therefrom for sealing gaps between rotational airfoils and adjacent stationary components. The seal strips may overlap each other and may be generally aligned with each other. The seal strips may flex during operation to further reduce the gap between the rotational airfoils and adjacent stationary components.

  9. The role of "rescue saccades" in tracking objects through occlusions.

    PubMed

    Zelinsky, Gregory J; Todor, Andrei

    2010-12-29

    We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking.

  10. Ingestion resistant seal assembly

    DOEpatents

    Little, David A [Chuluota, FL

    2011-12-13

    A seal assembly limits gas leakage from a hot gas path to one or more disc cavities in a gas turbine engine. The seal assembly includes a seal apparatus associated with a blade structure including a row of airfoils. The seal apparatus includes an annular inner shroud associated with adjacent stationary components, a wing member, and a first wing flange. The wing member extends axially from the blade structure toward the annular inner shroud. The first wing flange extends radially outwardly from the wing member toward the annular inner shroud. A plurality of regions including one or more recirculation zones are defined between the blade structure and the annular inner shroud that recirculate working gas therein back toward the hot gas path.

  11. Air riding seal with purge cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, Thomas D; Mills, Jacob A

    An air riding seal for a turbine in a gas turbine engine, where an annular piston is axial moveable within an annular piston chamber formed in a stator of the turbine and forms a seal with a surface on the rotor using pressurized air that forms a cushion in a pocket of the annular piston. A purge cavity is formed on the annular piston and is connected to a purge hole that extends through the annular piston to a lower pressure region around the annular piston or through the rotor to an opposite side. The annular piston is sealed alsomore » with inner and outer seals that can be a labyrinth seal to form an additional seal than the cushion of air in the pocket to prevent the face of the air riding seal from overheating.« less

  12. High-temperature, flexible, thermal barrier seal

    NASA Technical Reports Server (NTRS)

    Sirocky, Paul J. (Inventor); Steinetz, Bruce M. (Inventor)

    1991-01-01

    This device seals the sliding interfaces between structural panels that are roughly perpendicular to each other or whose edges are butted against one another. The nonuniformity of the gap between the panels requires significant flexibility along the seal length. The seal is mounted in a rectangular groove in a movable structural panel. A plurality of particles or balls is densely packed in an outer sheathing. The balls are laterally preloaded to maintain sealing contact with the adjacent wall using a pressurized linear bellows. Distortions in the adjacent panel are accommodated by rearrangement of the particles within the outer sheathing. Leakage through the seal is minimized by densely compacting the internal particles and by maintaining positive preload along the back side of the seal. The braid architecture of the outer sheathing is selected to minimize leakage through the seal and to resist mechanical abrasion.

  13. Brush Seals for Improved Steam Turbine Performance

    NASA Technical Reports Server (NTRS)

    Turnquist, Norman; Chupp, Ray; Baily, Fred; Burnett, Mark; Rivas, Flor; Bowsher, Aaron; Crudgington, Peter

    2006-01-01

    GE Energy has retrofitted brush seals into more than 19 operating steam turbines. Brush seals offer superior leakage control compared to labyrinth seals, owing to their compliant nature and ability to maintain very tight clearances to the rotating shaft. Seal designs have been established for steam turbines ranging in size from 12 MW to over 1200 MW, including fossil, nuclear, combined-cycle and industrial applications. Steam turbines present unique design challenges that must be addressed to ensure that the potential performance benefits of brush seals are realized. Brush seals can have important effects on the overall turbine system that must be taken into account to assure reliable operation. Subscale rig tests are instrumental to understanding seal behavior under simulated steam-turbine operating conditions, prior to installing brush seals in the field. This presentation discusses the technical challenges of designing brush seals for steam turbines; subscale testing; performance benefits of brush seals; overall system effects; and field applications.

  14. Tamper-indicating quantum optical seals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humble, Travis S; Williams, Brian P

    2015-01-01

    Confidence in the means for identifying when tampering occurs is critical for containment and surveillance technologies. Fiber-optic seals have proven especially useful for actively surveying large areas or inventories due to the extended transmission range and flexible layout of fiber. However, it is reasonable to suspect that an intruder could tamper with a fiber-optic sensor by accurately replicating the light transmitted through the fiber. In this contribution, we demonstrate a novel approach to using fiber-optic seals for safeguarding large-scale inventories with increased confidence in the state of the seal. Our approach is based on the use of quantum mechanical phenomenamore » to offer unprecedented surety in the authentication of the seal state. In particular, we show how quantum entangled photons can be used to monitor the integrity of a fiber-optic cable - the entangled photons serve as active sensing elements whose non-local correlations indicate normal seal operation. Moreover, we prove using the quantum no-cloning theorem that attacks against the quantum seal necessarily disturb its state and that these disturbances are immediately detected. Our quantum approach to seal authentication is based on physical principles alone and does not require the use of secret or proprietary information to ensure proper operation. We demonstrate an implementation of the quantum seal using a pair of entangled photons and we summarize our experimental results including the probability of detecting intrusions and the overall stability of the system design. We conclude by discussing the use of both free-space and fiber-based quantum seals for surveying large areas and inventories.« less

  15. Pleistocene microvertebrates from fissure-fillings in Thailand

    NASA Astrophysics Data System (ADS)

    Chaimanee, Yaowalak; Jaeger, Jean-Jacques; Suteethorn, Varavudh

    Microvertebrates (and among them specially, rodents) have contributed to the elaboration of precise biochronological time scales and to the reconstitution of Pleistocene paleoenvironments in several parts of the world (North America, Africa, Europe and Japan). They have been demonstrated to be highly sensitive to climatic changes since they are very sensitive to vegetation changes. Up to now, no data is available for Southeast Asia and very few information is available concerning the nature of climatic changes which affected that part of the tropical world during the Pleistocene. In the past few years, we have discovered several fissure fillings in Thailand yielding numerous remains of microvertebrates which have been extracted by dissolution in acetic acid solution. These deposits are the result of the feeding activity of predators, like owls or diurnal raptors, whose pellets are accumulated in caves or fissures. Eleven localities, located in Central (2), Eastern (1), Western (2) and Peninsular Thailand (6) have been investigated so far. Several rodent species, belonging to 9 genera of Murinae (rats and mice) and 9 genera of Sciuridae (squirrels) have been identified in these localities. The most important differences with the extant representatives often concern the size of the teeth of these fossil species. The meaning of these size differences is not yet clearly understood since they can be attributed either to significant time differences between localities (microevolution) or as the result of size variations related to climatic changes (clinical variations). More data will have to be collected to calibrate the temporal frame. Already, important modification of the geographic distribution of some species have been discovered which testify that during the Pleistocene, significative climatic changes have affected Southeast Asia. For example, Exilisciurus, a squirrel which is presently restricted to Borneo has been recognized in Peninsular Thailand. Also, Iomys

  16. Vascular occlusion with a balloon-expandable stent occluder.

    PubMed

    Moss, J G; Laborde, J C; Clem, M C; Rivera, F J; Encarnacion, C E; Meyer, K B; Palmaz, J C

    1994-05-01

    To evaluate the effectiveness of a new vascular occlusion device. The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. This new occlusive device offers immediate vascular occlusion with excellent stability.

  17. A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venbrux, Anthony C., E-mail: avenbrux@mfa.gwu.edu; Rudakov, Leon, E-mail: leonrudakov@artventivemedical.com; Plass, Andre, E-mail: andre.plass@usz.ch

    2013-05-24

    PurposeThe purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles.MethodsThe ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males,more » ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects.ResultsThe acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients.ConclusionsAlthough we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.« less

  18. 9 CFR 381.98 - Official seal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Official seal. 381.98 Section 381.98... Certificates; Certification Procedures § 381.98 Official seal. The official mark for use in sealing means of... and a serial number as shown below, and any seals approved by the Administrator for applying such mark...

  19. 9 CFR 381.98 - Official seal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Official seal. 381.98 Section 381.98... Certificates; Certification Procedures § 381.98 Official seal. The official mark for use in sealing means of... and a serial number as shown below, and any seals approved by the Administrator for applying such mark...

  20. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

    PubMed

    Kim, Yongsik; Oh, Tae-Ju; Misch, Carl E; Wang, Hom-Lay

    2005-02-01

    Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

  1. 1 CFR 18.8 - Seal.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Seal. 18.8 Section 18.8 General Provisions ADMINISTRATIVE COMMITTEE OF THE FEDERAL REGISTER PREPARATION, TRANSMITTAL, AND PROCESSING OF DOCUMENTS PREPARATION AND TRANSMITTAL OF DOCUMENTS GENERALLY § 18.8 Seal. Use of a seal on an original document or...

  2. 28 CFR 0.146 - Seals.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Seals. 0.146 Section 0.146 Judicial... Personnel and Certain Administrative Matters § 0.146 Seals. The Director of the Federal Bureau of... the U.S. Marshals Service shall each have custody of the seal pertaining to his respective...

  3. 28 CFR 0.146 - Seals.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Seals. 0.146 Section 0.146 Judicial... Personnel and Certain Administrative Matters § 0.146 Seals. The Director of the Federal Bureau of... the U.S. Marshals Service shall each have custody of the seal pertaining to his respective...

  4. 1 CFR 18.8 - Seal.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 1 General Provisions 1 2011-01-01 2011-01-01 false Seal. 18.8 Section 18.8 General Provisions ADMINISTRATIVE COMMITTEE OF THE FEDERAL REGISTER PREPARATION, TRANSMITTAL, AND PROCESSING OF DOCUMENTS PREPARATION AND TRANSMITTAL OF DOCUMENTS GENERALLY § 18.8 Seal. Use of a seal on an original document or...

  5. High-Temperature, Bellows Hybrid Seal

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor); Sirocky, Paul J. (Inventor)

    1994-01-01

    A high-temperature hybrid seal is constructed of multiple elements to meet the many demands placed on the seal. The primary elements are: a central high-temperature bellows, a braided ceramic sheath covering the bellows, an outer abrasion resistant sheath covering the ceramic sheath, and a structurally-sound seal-end termination.

  6. Flows of Newtonian and Power-Law Fluids in Symmetrically Corrugated Cappilary Fissures and Tubes

    NASA Astrophysics Data System (ADS)

    Walicka, A.

    2018-02-01

    In this paper, an analytical method for deriving the relationships between the pressure drop and the volumetric flow rate in laminar flow regimes of Newtonian and power-law fluids through symmetrically corrugated capillary fissures and tubes is presented. This method, which is general with regard to fluid and capillary shape, can also be used as a foundation for different fluids, fissures and tubes. It can also be a good base for numerical integration when analytical expressions are hard to obtain due to mathematical complexities. Five converging-diverging or diverging-converging geometrics, viz. wedge and cone, parabolic, hyperbolic, hyperbolic cosine and cosine curve, are used as examples to illustrate the application of this method. For the wedge and cone geometry the present results for the power-law fluid were compared with the results obtained by another method; this comparison indicates a good compatibility between both the results.

  7. Cure-in-place process for seals

    DOEpatents

    Hirasuna, Alan R.

    1981-01-01

    A cure-in-place process which allows a rubber seal element to be deformed to its service configuration before it is cross-linked and, hence, is a plastic and does not build up internal stress as a result of the deformation. This provides maximum residual strength to resist the differential pressure. Furthermore, the process allows use of high modulus formulations of the rubber seal element which would otherwise crack if cured and then deformed to its service configuration, resulting in a seal which has better gap bridging capability. Basically, the process involves positioning an uncured seal element in place, deforming it to its service configuration, heating the seal element, curing it in place, and then fully seating the seal.

  8. Air riding seal for a turbine

    DOEpatents

    Mills, Jacob A; Brown, Wesley D; Sexton, Thomas D; Jones, Russell B

    2016-07-19

    An air riding seal between a rotor and a stator in a turbine of a gas turbine engine, where an annular piston is movable in an axial direction within a housing that extends from the stator, and a bellows is secured to the annular piston to form a flexible air passageway from a compressed air inlet through the annular piston and into a cushion cavity that forms an air riding seal between the annular piston and the rotor sealing surface. In another embodiment, a flexible seal secured to and extending from the annular piston forms a sealing surface between the annular piston chamber and the annular piston to provide a seal and allow for axial movement.

  9. Groundwater drainage from fissures as a source for lahars

    NASA Astrophysics Data System (ADS)

    Johnson, P. J.; Valentine, G. A.; Stauffer, P. H.; Lowry, C. S.; Sonder, I.; Pulgarín, B. A.; Santacoloma, C. C.; Agudelo, A.

    2018-04-01

    One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have been heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. We consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 103 m3/m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. This simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.

  10. 46 CFR 501.11 - Official seal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 9 2010-10-01 2010-10-01 false Official seal. 501.11 Section 501.11 Shipping FEDERAL... Seal § 501.11 Official seal. (a) Description. Pursuant to section 201(c) of the Merchant Marine Act, 1936, as amended (46 U.S.C. 301(d)), the Commission prescribes its official seal, as adopted by the...

  11. 19 CFR 101.7 - Customs seal.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Customs seal. 101.7 Section 101.7 Customs Duties U... GENERAL PROVISIONS § 101.7 Customs seal. (a) Design. According to the design furnished by the Department of the Treasury, the Customs seal of the United States shall consist of the seal of the Department of...

  12. 46 CFR 501.11 - Official seal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 9 2011-10-01 2011-10-01 false Official seal. 501.11 Section 501.11 Shipping FEDERAL... Seal § 501.11 Official seal. (a) Description. Pursuant to section 201(c) of the Merchant Marine Act, 1936, as amended (46 U.S.C. 301(d)), the Commission prescribes its official seal, as adopted by the...

  13. 19 CFR 101.7 - Customs seal.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Customs seal. 101.7 Section 101.7 Customs Duties U... GENERAL PROVISIONS § 101.7 Customs seal. (a) Design. According to the design furnished by the Department of the Treasury, the Customs seal of the United States shall consist of the seal of the Department of...

  14. Advanced High Temperature Structural Seals

    NASA Astrophysics Data System (ADS)

    Newquist, Charles W.; Verzemnieks, Juris; Keller, Peter C.; Rorabaugh, Michael; Shorey, Mark

    2002-10-01

    This program addresses the development of high temperature structural seals for control surfaces for a new generation of small reusable launch vehicles. Successful development will contribute significantly to the mission goal of reducing launch cost for small, 200 to 300 pound payloads. Development of high temperature seals is mission enabling. For instance, ineffective control surface seals can result in high temperature (3100 F) flows in the elevon area exceeding structural material limits. Longer sealing life will allow use for many missions before replacement, contributing to the reduction of hardware, operation and launch costs.

  15. Advanced High Temperature Structural Seals

    NASA Technical Reports Server (NTRS)

    Newquist, Charles W.; Verzemnieks, Juris; Keller, Peter C.; Rorabaugh, Michael; Shorey, Mark

    2002-01-01

    This program addresses the development of high temperature structural seals for control surfaces for a new generation of small reusable launch vehicles. Successful development will contribute significantly to the mission goal of reducing launch cost for small, 200 to 300 pound payloads. Development of high temperature seals is mission enabling. For instance, ineffective control surface seals can result in high temperature (3100 F) flows in the elevon area exceeding structural material limits. Longer sealing life will allow use for many missions before replacement, contributing to the reduction of hardware, operation and launch costs.

  16. Pressure sensor for sealed containers

    DOEpatents

    Hodges, Franklin R.

    2001-01-01

    A magnetic pressure sensor for sensing a pressure change inside a sealed container. The sensor includes a sealed deformable vessel having a first end attachable to an interior surface of the sealed container, and a second end. A magnet mounted to the vessel second end defining a distance away from the container surface provides an externally detectable magnetic field. A pressure change inside the sealed container causes deformation of the vessel changing the distance of the magnet away from the container surface, and thus the detectable intensity of the magnetic field.

  17. Fiber Optic Safeguards Sealing System

    DTIC Science & Technology

    1978-01-01

    8217 or trade names does not constitute an official indorsement or approval of the use thereof. Destroy this report when it is no longer needed. Do not...an intergrity check of a seal than to photograph the seal’s fingerprints and to match positive/negative overlays. The seal identification time and

  18. Occlusion issues in early Renaissance art

    PubMed Central

    Gillam, Barbara

    2011-01-01

    Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings. PMID:23145262

  19. Sealing Assembly for Sealing a Port and the Like

    NASA Technical Reports Server (NTRS)

    Haas, Jon W. (Inventor); Haupt, Charles W. (Inventor)

    2000-01-01

    The sealing assembly for a port of a valve or the like is disclosed. In detail, the sealing assembly includes the port having a circular shaped end with a circular shaped knife-edge thereon. The sealing assembly further includes a hollow cap having a closed first end with an aperture therethrough and an open second end. The cap further includes internal threads adapted to mate with the external threads of the port. A gasket is mounted within the cap having flat first and second principle sides and made of a deformable metal, the first principle side of the gasket for mounting against the circular shaped knife edge of the port. A plunger having a circular shaped disc portion is adapted to fit within the hollow cap and is engagable with the first principle surface of the gasket and includes a shaft portion extending out of the aperture. The cap and shaft of the plunger include external wrenching flats. Thus when the cap is screwed onto the port and the plunger is prevented from rotating by a wrench mounted on the wrenching flats of the shaft portion of the plunger, the gasket is forced into engagement with the knife edge in pure compression and no rotation of the gasket occurs causing the knife edge to locally deform the gasket sealing of the port.

  20. Development of advanced seals for space propulsion turbomachinery

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Liang, A. D.; Childs, D. W.; Proctor, M. P.

    1992-01-01

    Current activities in seals for space propulsion turbomachinery that the NASA Lewis Research Center sponsors are surveyed. The overall objective is to provide the designer and researcher with the concepts and the data to control seal dynamics and leakage. Included in the program are low-leakage seals, such as the brush seal, the 'ceramic rope' seal, low-leakage seals for liquid oxygen turbopumps, face seals for two phase flow, and swirl brakes for stability. Two major efforts are summarized: a seal dynamics in rotating machinery and an effort in seal code development.

  1. Heartworm (Acanthocheilonema spirocauda) and seal louse (Echinophthirius horridus) infections in harbour seals (Phoca vitulina) from the North and Baltic Seas

    NASA Astrophysics Data System (ADS)

    Lehnert, Kristina; Schwanke, Eva; Hahn, Kerstin; Wohlsein, Peter; Siebert, Ursula

    2016-07-01

    The seal louse (Echinophthirius [E.] horridus) and the heartworm (Acanthocheilonema [A.] spirocauda) are parasites of harbour seal (Phoca vitulina). Little is known about the role of the seal louse as a potential vector and its role for the development and transmission of heartworm larvae to their final host, the harbour seal. The life-cycle of the heartworm is still not fully understood. For the presented study, findings of 1191 stranded harbour seals collected along the North- and Baltic Sea coast between 1996 and 2013 were examined. 4.4% (n = 53) of these harbour seals were infected with adult heartworms and 3.4% (n = 40) harbour seals carried seal lice. The highest prevalence and level of infection with adult heartworms (A. spirocauda) (9.3%) and seal lice (E. horridus) (8.9%) were found on yearling harbour seals (7-18 months) compared to neonate and adult seals. Investigating seal lice (n = 35) for larval heartworm stages one larvae was encountered in an ethanol-fixated seal louse. During a health monitoring survey of live harbour seals, 109 animals were captured and examined during spring and autumn between 2008 and 2014. Blood samples were taken and microfilariae were discovered in blood smears in 41% (n = 45) of the examined harbour seals. Yearling seals (n = 21) showed higher prevalence (86%) and level of infection with microfilariae than adults. Microfilariae were identified as A. spirocauda by sequencing the species-specific COI gene in 24 blood samples. The high prevalence of microfilariae of A. spirocauda in blood samples (41%) is in contrast to the low prevalence of mature infections/adult specimens in stranded seals (4.4%) investigated. Although rare parasites of seals, the recent increase in prevalence of heartworm and seal lice in stranded seals and the relatively high occurrence of microfilaria in the free-ranging population underscore the importance of further studies investigating the immunology of infections and their transmission pathways, as

  2. Turbine Seal Research at NASA GRC

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Steinetz, Bruce M.; Delgado, Irebert R.; Hendricks, Robert C.

    2011-01-01

    Low-leakage, long-life turbomachinery seals are important to both Space and Aeronautics Missions. (1) Increased payload capability (2) Decreased specific fuel consumption and emissions (3) Decreased direct operating costs. NASA GRC has a history of significant accomplishments and collaboration with industry and academia in seals research. NASA's unique, state-of-the-art High Temperature, High Speed Turbine Seal Test Facility is an asset to the U.S. Engine / Seal Community. Current focus is on developing experimentally validated compliant, non-contacting, high temperature seal designs, analysis, and design methodologies to enable commercialization.

  3. Aerodynamic seals for rotary machine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bidkar, Rahul Anil; Cirri, Massimiliano; Thatte, Azam Mihir

    2016-02-09

    An aerodynamic seal assembly for a rotary machine includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having multiple labyrinth teeth therebetween facing the rotor. The sealing device segment also includes multiple flexures connected to the shoe plate and to a top interface element, wherein the multiple flexures are configured to allow the high pressure fluid to occupy a forward cavity and the low pressure fluid to occupy an aft cavity. Further, the sealing device segments include amore » secondary seal attached to the top interface element at one first end and positioned about the flexures and the shoe plate at one second end.« less

  4. The retention of pit and fissure sealants placed in primary school children by Dental Health Services, Victoria.

    PubMed

    Messer, L B; Calache, H; Morgan, M V

    1997-08-01

    The benefit of a public sector sealant programme for children in Australia is yet to be established. This study evaluated sealants placed by therapists of the School Dental Service in Victoria, between 1989 and 1994, on permanent teeth of children in 15 primary schools in Melbourne. Seven hundred and seventy four children aged 6-12 years were examined in school dental clinics by six calibrated examiners. A total of 5363 sealants placed on 2875 permanent teeth (including 2616 first molars, 91 per cent of sample) up to four and a half years previously was examined. Values for complete and partial sealant retention were highest for premolars (86 per cent, 9 per cent respectively, total 95 per cent); similar for occlusal surfaces of maxillary and mandibular first molars (63 per cent, 30 per cent; 62 per cent, 32 per cent respectively) and buccal pits of mandibular molars (66 per cent); and low for pits/fissures of Carabelli's cusps of maxillary molars (44 per cent). Cross-sectional examination up to 24 months for both maxillary and mandibular first molars indicated average values of 67 per cent complete retention, 27 per cent partial retention, 6 per cent missing; thereafter complete retention decreased and partial retention increased. Sealant failures in the six months post-placement were attributed to technique failure. Regardless of sealant retention, caries experience was low under partially retained or missing sealants (4.5 per cent) and completely retained sealants (0.4 per cent). It is concluded that the SDS sealant programme is a sound preventive dental public health approach.

  5. Actively controlled shaft seals for aerospace applications

    NASA Technical Reports Server (NTRS)

    Salant, Richard F.

    1994-01-01

    This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100 C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changed suddenly.

  6. Histochemical changes of occlusal surface enamel of permanent teeth, where dental caries is questionable vs sound enamel surfaces.

    PubMed

    Michalaki, M; Oulis, C J; Pandis, N; Eliades, G

    2016-12-01

    This in vitro study was to classify questionable for caries occlusal surfaces (QCOS) of permanent teeth according to ICDAS codes 1, 2, and 3 and to compare them in terms of enamel mineral composition with the areas of sound tissue of the same tooth. Partially impacted human molars (60) extracted for therapeutic reasons with QCOS were used in the study, photographed via a polarised light microscope and classified according to the ICDAS II (into codes 1, 2, or 3). The crowns were embedded in clear self-cured acrylic resin and longitudinally sectioned at the levels of the characterised lesions and studied by SEM/EDX, to assess enamel mineral composition of the QCOS. Univariate and multivariate random effect regressions were used for Ca (wt%), P (wt%), and Ca/P (wt%). The EDX analysis indicated changes in the Ca and P contents that were more prominent in ICDAS-II code 3 lesions compared to codes 1 and 2 lesions. In these lesions, Ca (wt%) and P (wt%) concentrations were significantly decreased (p = 0.01) in comparison with sound areas. Ca and P (wt%) contents were significantly lower (p = 0.02 and p = 0.01 respectively) for code 3 areas in comparison with codes 1 and 2 areas. Significantly higher (p = 0.01) Ca (wt%) and P (wt%) contents were found on sound areas compared to the lesion areas. The enamel of occlusal surfaces of permanent teeth with ICDAS 1, 2, and 3 lesions was found to have different Ca/P compositions, necessitating further investigation on whether these altered surfaces might behave differently on etching preparation before fissure sealant placement, compared to sound surfaces.

  7. 2008 NASA Seal/Secondary Air System Workshop

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Editor); Hendricks, Robert C. (Editor); Delgado, Irebert R. (Editor)

    2009-01-01

    The 2008 NASA Seal/Secondary Air System Workshop covered the following topics: (i) Overview of NASA s new Orion project aimed at developing a new spacecraft that will fare astronauts to the International Space Station, the Moon, Mars, and beyond; (ii) Overview of NASA s fundamental aeronautics technology project; (iii) Overview of NASA Glenn s seal project aimed at developing advanced seals for NASA s turbomachinery, space, and reentry vehicle needs; (iv) Reviews of NASA prime contractor, vendor, and university advanced sealing concepts, test results, experimental facilities, and numerical predictions; and (v) Reviews of material development programs relevant to advanced seals development. Turbine engine studies have shown that reducing seal leakage as well as high-pressure turbine (HPT) blade tip clearances will reduce fuel burn, lower emissions, retain exhaust gas temperature margin, and increase range. Turbine seal development topics covered include a method for fast-acting HPT blade tip clearance control, noncontacting low-leakage seals, intershaft seals, and a review of engine seal performance requirements for current and future Army engine platforms.

  8. High temperature dynamic engine seal technology development

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Dellacorte, Christopher; Machinchick, Michael; Mutharasan, Rajakkannu; Du, Guang-Wu; Ko, Frank; Sirocky, Paul J.; Miller, Jeffrey H.

    1992-01-01

    Combined cycle ramjet/scramjet engines being designed for advanced hypersonic vehicles, including the National Aerospace Plane (NASP), require innovative high temperature dynamic seals to seal the sliding interfaces of the articulated engine panels. New seals are required that will operate hot (1200 to 2000 F), seal pressures ranging from 0 to 100 psi, remain flexible to accommodate significant sidewall distortions, and resist abrasion over the engine's operational life. This report reviews the recent high temperature durability screening assessments of a new braided rope seal concept, braided of emerging high temperature materials, that shows promise of meeting many of the seal demands of hypersonic engines. The paper presents durability data for: (1) the fundamental seal building blocks, a range of candidate ceramic fiber tows; and for (2) braided rope seal subelements scrubbed under engine simulated sliding, temperature, and preload conditions. Seal material/architecture attributes and limitations are identified through the investigations performed. The paper summarizes the current seal technology development status and presents areas in which future work will be performed.

  9. 29 CFR 4002.11 - Seal.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Seal. 4002.11 Section 4002.11 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION GENERAL BYLAWS OF THE PENSION BENEFIT GUARANTY CORPORATION § 4002.11 Seal. The seal of the Corporation shall be in such form as may be approved from time to...

  10. 29 CFR 4002.11 - Seal.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Seal. 4002.11 Section 4002.11 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION GENERAL BYLAWS OF THE PENSION BENEFIT GUARANTY CORPORATION § 4002.11 Seal. The seal of the Corporation shall be in such form as may be approved from time to...

  11. Ultrasonic dip seal maintenance system

    DOEpatents

    Poindexter, Allan M.; Ricks, Herbert E.

    1978-01-01

    A system for removing impurities from the surfaces of liquid dip seals and or wetting the metal surfaces of liquid dip seals in nuclear components. The system comprises an ultrasonic transducer that transmits ultrasonic vibrations along an ultrasonic probe to the metal and liquid surfaces of the dip seal thereby loosening and removing those impurities.

  12. Wet powder seal for gas containment

    DOEpatents

    Stang, Louis G.

    1982-01-01

    A gas seal is formed by a compact layer of an insoluble powder and liquid filling the fine interstices of that layer. The smaller the particle size of the selected powder, such as sand or talc, the finer will be the interstices or capillary spaces in the layer and the greater will be the resulting sealing capacity, i.e., the gas pressure differential which the wet powder layer can withstand. Such wet powder seal is useful in constructing underground gas reservoirs or storage cavities for nuclear wastes as well as stopping leaks in gas mains buried under ground or situated under water. The sealing capacity of the wet powder seal can be augmented by the hydrostatic head of a liquid body established over the seal.

  13. Wet powder seal for gas containment

    DOEpatents

    Stang, L.G.

    1979-08-29

    A gas seal is formed by a compact layer of an insoluble powder and liquid filling the fine interstices of that layer. The smaller the particle size of the selected powder, such as sand or talc, the finer will be the interstices or capillary spaces in the layer and the greater will be the resulting sealing capacity, i.e., the gas pressure differential which the wet powder layer can withstand. Such wet powder seal is useful in constructing underground gas reservoirs or storage cavities for nuclear wastes as well as stopping leaks in gas mains buried under ground or situated under water. The sealing capacity of the wet powder seal can be augmented by the hydrostatic head of a liquid body established over the seal.

  14. A Sample Return Container with Hermetic Seal

    NASA Technical Reports Server (NTRS)

    Kong, Kin Yuen; Rafeek, Shaheed; Sadick, Shazad; Porter, Christopher C.

    2000-01-01

    A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers and then hermetically seal samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the sampler's featured drill tip for interfacing, transfer-ring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses a few isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The drill based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. Again, the sampler provides all sealing actuation. This sample return container and co-engineered sample acquisition system are being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program.

  15. [Sealing properties of three resin-based sealers].

    PubMed

    Mai, Sui; Wu, Shiyu; Gu, Lisha; Qi, Yipin; Sun, Qiurong; Ling, Junqi

    2014-11-01

    To evaluate the sealing properties of three resin- based sealers, EndoREZ, RealSEAL and RealSEAL SE. Forthy-eight extracted human anterior teeth with single root and canal were prepared using ProTaper files with crown-down technique to F3. The teeth were filled with three sealer respectively with hot gutta- percha vertical condensation technique simulating the clinical situation. Leakage quantity was detected using computerized fluid filtration meter with 10 samples in each group. The cross section morphology of apical parts of roots of 5 mm was observed with scanning electron microscope and transmission electron microscope in 3 samples of each group, respectively. The leakage quantity of EndoREZ, RealSEAL and RealSEAL SE were (2.61±0.60), (1.43±0.11) and (1.76±0.18) µl/min, respectively. The gaps between the the sealer and the canal wall were increased in in order of RealSEAL, RealSEAL SE and EndoREZ. No obvious demineralized dentin under EndoREZ and the smear layer was not completed removed. The partly demineralized dentin was observed under RealSEAL and the smear layer was totally removed. The partly demineralized dentin was seen under RealSEAL SE and the majority of smear layer was removed. Among the three resin- based sealers, RealSEAL has the best sealing properties, followed by RealSEAL SE and EndoREZ.

  16. Time to aortic occlusion: It's all about access.

    PubMed

    Romagnoli, Anna; Teeter, William; Pasley, Jason; Hu, Peter; Hoehn, Melanie; Stein, Deborah; Scalea, Thomas; Brenner, Megan

    2017-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less invasive method of proximal aortic occlusion compared with resuscitative thoracotomy with aortic cross-clamping (RTACC). This study compared time to aortic occlusion with REBOA and RTACC, both including and excluding time required for common femoral artery (CFA) cannulation. This was a retrospective, single-institution review of REBOA or RTACC performed between February 2013 and January 2016. Time of skin incision to aortic cross-clamp for RTACC, time required for CFA cannulation by percutaneous and open methods, and time from guide-wire insertion to balloon inflation at Zone 1 for REBOA, were obtained from videographic recordings. Eighteen RTACC and 21 REBOAs were performed. Median (Q1, Q3) time from skin incision to aortic cross-clamping was 317 seconds (227, 551 seconds). Median (Q1, Q3) time from start of arterial access to Zone 1 balloon occlusion was 474 seconds (431, 572 seconds) (vs. RTACC, p = 0.01). All REBOA procedures were performed with the same device. The median time to complete CFA cannulation was 247 seconds (range, 164-343 seconds), with no difference between percutaneous or open procedures (p = 0.07). The median (Q1, Q3) time to aortic occlusion in REBOA once arterial access had been established was 245 seconds (179, 295.5 seconds), which was significantly shorter than RTACC (p = 0.003). Once CFA access is achieved, time to aortic occlusion is faster with REBOA. Time to aortic occlusion is less than the time required to cannulate the CFA either by percutaneous or open approaches, emphasizing the importance of accurate and expedient CFA access. Resuscitative endovascular balloon occlusion of the aorta may represent a feasible alternative to thoracotomy for aortic occlusion. Time to aortic occlusion will likely decrease with the advent of newer REBOA technology. The rate-limiting portion of REBOA continues to be obtaining CFA access. Therapeutic, level V.

  17. Predictors of early stent occlusion among plastic biliary stents.

    PubMed

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  18. Influence of denture adhesives on occlusion and disocclusion times.

    PubMed

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Sealed container sampling device

    NASA Technical Reports Server (NTRS)

    Hennigan, T. J.

    1969-01-01

    Sampling device, by means of a tapered needle, pierces a sealed container while maintaining the seal and either evacuates or pressurizes the container. This device has many applications in the chemical, preservative and battery-manufacturing industries.

  20. Bellow seal and anchor

    DOEpatents

    Mansure, Arthur J.

    2001-01-01

    An annular seal is made of a collapsible bellows. The bellows can function as an anchor or a seal and is easily set into position using relative component movement. The bellows folds can be slanted and their outer sealing edges can have different profiles to meet expected conditions. The bellows is expanded for insertion to reduce its outer dimension and sets by compaction as a result of relative movement. The bellows can be straight or tapered and is settable with a minimal axial force.

  1. Development of advanced seal verification

    NASA Technical Reports Server (NTRS)

    Workman, Gary L.; Kosten, Susan E.; Abushagur, Mustafa A.

    1992-01-01

    The purpose of this research is to develop a technique to monitor and insure seal integrity with a sensor that has no active elements to burn-out during a long duration activity, such as a leakage test or especially during a mission in space. The original concept proposed is that by implementing fiber optic sensors, changes in the integrity of a seal can be monitored in real time and at no time should the optical fiber sensor fail. The electrical components which provide optical excitation and detection through the fiber are not part of the seal; hence, if these electrical components fail, they can be easily changed without breaking the seal. The optical connections required for the concept to work does present a functional problem to work out. The utility of the optical fiber sensor for seal monitoring should be general enough that the degradation of a seal can be determined before catastrophic failure occurs and appropriate action taken. Two parallel efforts were performed in determining the feasibility of using optical fiber sensors for seal verification. In one study, research on interferometric measurements of the mechanical response of the optical fiber sensors to seal integrity was studied. In a second study, the implementation of the optical fiber to a typical vacuum chamber was implemented and feasibility studies on microbend experiments in the vacuum chamber were performed. Also, an attempt was made to quantify the amount of pressure actually being applied to the optical fiber using finite element analysis software by Algor.

  2. Assessing MMOD Impacts on Seal Performance

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III; Daniels, C.; Dunlap, P.; Steinetz, B.

    2007-01-01

    The elastomer seal needed to seal in cabin air when NASA s Crew Exploration Vehicle is docked is exposed to space prior to docking. While open to space, the seal might be hit by orbital debris or meteoroids. The likelihood of damage of this type depends on the size of the particle. Our campaign is designed to find the smallest particle that will cause seal failure resulting in loss of mission. We will then be able to estimate environmental risks to the seal. Preliminary tests indicate seals can withstand a surprising amount of damage and still function. Collaborations with internal and external partners are in place and include seal leak testing, modeling of the space environment using a computer code known as BUMPER, and hypervelocity impact (HVI) studies at Caltech. Preliminary work at White Sands Test Facility showed a 0.5 mm diameter HVI damaged areas about 7 times that diameter, boring deep (5 mm) into elastomer specimens. BUMPER simulations indicate there is a 1 in 1440 chance of getting hit by a particle of diameter 0.08 cm for current Lunar missions; and 0.27 cm for a 10 year ISS LIDS seal area exposure.

  3. Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

    PubMed Central

    Choi, Sulki

    2017-01-01

    PURPOSE The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness. PMID:29279761

  4. Actively Controlled Shaft Seals for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Salant, Richard F.; Wolff, Paul

    1995-01-01

    This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with a piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changes suddenly. the experimental results were compared to the predictions from the mathematical model. The model was successful in predicting the trends in leakage rate that occurred as the balance ratio and sealed pressure changed

  5. Multi-layer seal for electrochemical devices

    DOEpatents

    Chou, Yeong-Shyung [Richland, WA; Meinhardt, Kerry D [Kennewick, WA; Stevenson, Jeffry W [Richland, WA

    2010-11-16

    Multi-layer seals are provided that find advantageous use for reducing leakage of gases between adjacent components of electrochemical devices. Multi-layer seals of the invention include a gasket body defining first and second opposing surfaces and a compliant interlayer positioned adjacent each of the first and second surfaces. Also provided are methods for making and using the multi-layer seals, and electrochemical devices including said seals.

  6. Multi-layer seal for electrochemical devices

    DOEpatents

    Chou, Yeong-Shyung [Richland, WA; Meinhardt, Kerry D [Kennewick, WA; Stevenson, Jeffry W [Richland, WA

    2010-09-14

    Multi-layer seals are provided that find advantageous use for reducing leakage of gases between adjacent components of electrochemical devices. Multi-layer seals of the invention include a gasket body defining first and second opposing surfaces and a compliant interlayer positioned adjacent each of the first and second surfaces. Also provided are methods for making and using the multi-layer seals, and electrochemical devices including said seals.

  7. Optimal Dosing of Botulinum Toxin for Treatment of Chronic Anal Fissure: A Systematic Review and Meta-Analysis.

    PubMed

    Lin, Jin Xin; Krishna, Sanjeev; Su'a, Bruce; Hill, Andrew G

    2016-09-01

    Chronic anal fissures are associated with significant morbidity and reduced quality of life. Studies have investigated the efficacy of botulinum toxin with variable results; thus, there is currently no consensus on botulinum toxin dose or injection sites. This study aimed to systematically analyze trials studying the efficacy of botulinum toxin for treatment of chronic anal fissure to identify an optimum dosage and injection regimen. A comprehensive review of the literature was conducted according to PRISMA guidelines. PubMed/Medline, Embase, Scopus, and the Cochrane Library were searched from inception to June 2015. All clinical trials that investigated the efficacy of botulinum toxin for chronic anal fissure were selected according to specific criteria. The interventions used were various doses of botulinum toxin. Clinical outcomes, dosage, and injection site data were evaluated with weighted pooled results for each dosage and 95% confidence intervals. There were 1158 patients, with 661 in botulinum toxin treatment arms, from 18 clinical trials included in this review. The outcomes of interest were 3-month healing, incontinence, and recurrence rates. Meta-regression analysis demonstrated a small decrease in healing rate (0.34%; 95% CI, 0-0.68; p = 0.048) with each increase in dosage, a small increase in incontinence rate (1.02 times; 95% CI, 1.0002-1.049; p = 0.048) with each increase in dosage and a small increase in recurrence rate (1.037 times; 95% CI, 1.018-1.057; p = 0.0002) with each increase in dosage. The optimum injection site could not be determined. This study was limited by weaknesses in the underlying evidence, such as variable quality, short follow-up, and a limited range of doses represented. Fissure healing with lower doses of botulinum toxin is as effective as with high doses. Lower doses also reduce the risk of incontinence and recurrence in the long term.

  8. Sealed head access area enclosure

    DOEpatents

    Golden, Martin P.; Govi, Aldo R.

    1978-01-01

    A liquid-metal-cooled fast breeder power reactor is provided with a sealed head access area enclosure disposed above the reactor vessel head consisting of a plurality of prefabricated structural panels including a center panel removably sealed into position with inflatable seals, and outer panels sealed into position with semipermanent sealant joints. The sealant joints are located in the joint between the edge of the panels and the reactor containment structure and include from bottom to top an inverted U-shaped strip, a lower layer of a room temperature vulcanizing material, a separator strip defining a test space therewithin, and an upper layer of a room temperature vulcanizing material. The test space is tapped by a normally plugged passage extending to the top of the enclosure for testing the seal or introducing a buffer gas thereinto.

  9. MOLDED SEALING ELEMENT

    DOEpatents

    Bradford, B.W.; Skinner, W.J.

    1959-03-24

    Molded sealing elements suitable for use under conditions involving exposure to uranium hexafluoride vapor are described. Such sealing elements are made by subjecting graphitic carbons to a preliminary treatment with uranium hexafluoride vapor, and then incorporating polytetrafluorethylene in them. The resulting composition has good wear resistant and frictional properties and is resistant to disintegration by uranium hexafluoride over long periods of exposure.

  10. Anaplasic astrocytoma with exophytic growth in Sylvian fissure in a pediatric patient: a case report.

    PubMed

    Guerra-Mora, José Raúl; Bravo-Ángel, Ulises; Hernández-Reséndiz, Rodrigo Efraín; Vicuña-González, Rosa María; Frías-Guillén, Jessica; Bercholc-Urinowsky, Irina Jeanette; Bravo-Reyna, Carlos Cesar; García-González, Ulises

    2018-04-01

    Gliomas are the most frequent supratentorial intracranial tumors in the pediatric population. Usually, they are intra-axial lesions with a characteristic image pattern, however, there are few reported cases of gliomas with exophytic growth. There are no previous reports in the literature of gliomas with exophytic growth in the Sylvian fissure. Fourteen year-old female patient who started with seizures. In imaging studies, a neoplasic mass with an exophytic portion in the left Sylvian fissure was found. Macroscopically, total resection was performed, definitive diagnosis was anaplastic astrocytoma. She presented recurrence and is currently receiving adjuvant treatment. Supratentorial gliomas with exophytic growth are extremely rare. We report the first case in the pediatric population, and we consider it is important to know its imaging and macroscopic characteristics for its initial management and to take it into account as a differential diagnosis of exophytic lesions.

  11. Simulation of the Flow Through Porous Layers Composed of Converging-Diverging Capillary Fissures or Tubes

    NASA Astrophysics Data System (ADS)

    Walicka, A.

    2018-02-01

    In this paper, a porous medium is modelled by a network of converging-diverging capillaries which may be considered as fissures or tubes. This model makes it necessary to consider flows through capillary fissures or tubes. Therefore an analytical method for deriving the relationships between pressure drops, volumetric flow rates and velocities for the following fluids: Newtonian, polar, power-law, pseudoplastic (DeHaven and Sisko types) and Shulmanian, was developed. Next, considerations on the models of pore network for Newtonian and non-Newtonian fluids were presented. The models, similar to the schemes of central finite differences may provide a good basis for transforming the governing equations of a flow through the porous medium into a set of linear or quasi-linear algebraic equations. It was shown that the some coefficients in these algebraic equations depend on the kind of the capillary convergence.

  12. Seal coat research project

    DOT National Transportation Integrated Search

    1999-12-01

    This study evaluates the use of seal coating as a method to protect bituminous pavements from oxidation, water infiltration, and raveling. The Minnesota Department of Transportation (Mn/DOT) applied seal coating to a roadway segment of Trunk Highway ...

  13. Steam Turbine Flow Path Seals (a Review)

    NASA Astrophysics Data System (ADS)

    Neuimin, V. M.

    2018-03-01

    Various types of shroud, diaphragm, and end seals preventing idle leak of working steam are installed in the flow paths of steam turbine cylinders for improving their efficiency. Widely known labyrinth seals are most extensively used in the Russian turbine construction industry. The category of labyrinth seals also includes seals with honeycomb inserts. The developers of seals with honeycomb inserts state that the use of such seals makes it possible to achieve certain gain due to smaller leaks of working fluid and more reliable operation of the system under the conditions in which the rotor rotating parts may rub against the stator elements. However, a positive effect can only be achieved if the optimal design parameters of the honeycomb structure are fulfilled with due regard to the specific features of its manufacturing technology and provided that this structure is applied in a goal-seeking manner in the seals of steam and gas turbines and compressors without degrading their vibration stability. Calculated and preliminary assessments made by experts testify that the replacement of conventional labyrinth seals by seals with honeycomb inserts alone, due to which the radial gaps in the shroud seal can be decreased from 1.5 to 0.5 mm, allows the turbine cylinder efficiency to be increased at the initial stage by approximately 1% with the corresponding gain in the turbine set power output. The use of rectangular-cellular seals may result, according to estimates made by their developers, in a further improvement of turbine efficiency by 0.5-1.0%. The labor input required to fabricate such seals is six to eight times smaller than that to fabricate labyrinth seals with honeycomb inserts. Recent years have seen the turbine construction companies of the United States and Germany advertising the use of abradable (sealing) coatings (borrowed from the gas turbine construction technology) in the turbine designs instead of labyrinth seals. The most efficient performance of

  14. Damping seals for turbomachinery

    NASA Technical Reports Server (NTRS)

    Vonpragenau, G. L.

    1985-01-01

    Rotor whirl stabilization of high performance turbomachinery which operates at supercritical speed is discussed. Basic whirl driving forces are reviewed. Stabilization and criteria are discussed. Damping seals are offered as a solution to whirl and high vibration problems. Concept, advantages, retrofitting, and limits of damping seals are explained. Dynamic and leakage properties are shown to require a rough stator surface for stability and efficiency. Typical seal characteristics are given for the case of the high pressure oxidizer turbopump of the Space Shuttle. Ways of implementation and bearing load effects are discussed.

  15. High temperature seal for large structural movements

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M. (Inventor); Dunlap, Jr., Patrick H. (Inventor)

    2004-01-01

    A high temperature sealing system is operative to seal an interface between adjacent hot structures and to minimize parasitic flow between such structures that move relative to one another in-plane or out-of-plane. The sealing system may be used to seal thrust-directing ramp structures of a reusable launch vehicle and includes a channel and a plurality of movable segmented sealing elements. Adjacent ramp structures include edge walls which extend within the channel. The sealing elements are positioned along the sides of the channel and are biased to engage with the inner surfaces of the ramp structures. The segmented sealing elements are movable to correspond to the contour of the thrust-directing ramp structures. The sealing system is operative to prevent high temperature thrust gases that flow along the ramp structures from infiltrating into the interior of the vehicle.

  16. Spring loaded compliant seal for high temperature use

    DOEpatents

    Memmen, Robert L; Fedock, John A; Downs, James P

    2013-10-15

    A flexible seal having an X-shaped cross section that forms four contact points on four contact surfaces of two opposed seal slots. The flexible seal is used for a component in which the two seal slots undergo a large deflection such that the opposed slots are not aligned and a rigid seal will not form an adequate seal. The flexible seal can be used in a component of a combustor or a turbine in a gas turbine engine where opposed seal slots undergo the large deflection during operation.

  17. Crack sealing and filling: best practices.

    DOT National Transportation Integrated Search

    2015-10-01

    This study investigated the current state of practice for crack sealing/filling. In addition, the INDOT crack sealing/filling practice was : experimentally evaluated for the effectiveness of crack sealing/filling, the effectiveness of routing, the pe...

  18. Advanced Seal Development for Large Industrial Gas Turbines

    NASA Technical Reports Server (NTRS)

    Chupp, Raymond E.

    2006-01-01

    Efforts are in progress to develop advanced sealing for large utility industrial gas turbine engines (combustion turbines). Such seals have been under developed for some time for aero gas turbines. It is desired to transition this technology to combustion turbines. Brush seals, film riding face and circumferential seals, and other dynamic and static sealing approaches are being incorporated into gas turbines for aero applications by several engine manufacturers. These seals replace labyrinth or other seals with significantly reduced leakage rates. For utility industrial gas turbines, leakage reduction with advanced sealing can be even greater with the enormous size of the components. Challenges to transitioning technology include: extremely long operating times between overhauls; infrequent but large radial and axial excursions; difficulty in coating larger components; and maintenance, installation, and durability requirements. Advanced sealing is part of the Advanced Turbine Systems (ATS) engine development being done under a cooperative agreement between Westinghouse and the US Department of Energy, Office of Fossil Energy. Seal development focuses on various types of seals in the 501ATS engine both at dynamic and static locations. Each development includes rig testing of candidate designs and subsequent engine validation testing of prototype seals. This presentation gives an update of the ongoing ATS sealing efforts with special emphasis on brush seals.

  19. Sealing apparatus utilizing a conformable member

    DOEpatents

    Neef, William S.; Lambert, Donald R.

    1988-01-01

    Sealing apparatus and method, comprising first and second surfaces or membranes, at least one of which surfaces is deformable, placed in proximity to one another. Urging means cause these surfaces to contact one another in a manner such that the deformable surface "deforms" to conform to the geometry of the other surface, thereby creating a seal. The seal is capable of undergoing multiple cycles of sealing and unsealing.

  20. Chip seal design and specifications : final report.

    DOT National Transportation Integrated Search

    2016-12-01

    Chip seals or seal coats, are a pavement preservation method constructed using a layer of asphalt binder that is covered by a uniformly graded aggregate. The benefits of chip seal include: sealing surface cracks, keeping water from penetrating the su...

  1. Sealants in dentistry: a systematic review of the literature.

    PubMed

    Condò, R; Cioffi, A; Riccio, A; Totino, M; Condò, S G; Cerroni, L

    2013-03-01

    The occlusal surface is the most affected area by dental caries and the sealing of the pits and of the fissures has been found, in time, the preventive method most effective trying to counteract the onset. Currently, the WHO considers it as a primary preventive measure, in other words one of the most effective and least invasive available to ensure the complete protection and the total preservation of the occlusal carious by the phenomenon. THE AIM OF THIS WORK HAS BEEN TO PERFORM A SYSTEMATIC REVIEW OF THE LITERATURE ON CLINICAL TRIALS OF DIFFERENT SEALING MATERIALS, IN ORDER TO: compare their individual characteristics, highlight the reliability and the long-term efficacy and identify the most significant variables, both technological and clinics, in order to declare whether or not the success of this method prior. The research has been carried out in the MEDLINE database by choosing keywords as "sealants" and "follow up". Only studies published in the last thirteen years have been considered and have been evaluated only types of scientific articles that fall within the definition of Anglo-Saxon "Clinical Trial" and "Controlled Clinical Trial", excluding all experimental works in vitro, case-reports, meta-analyzes and literature reviews. Have been also considered only scientific papers on patients between the ages of 0 and 18 years. Out of 29 studies, evaluating a total of 2900 individuals (aged between 2.5 and 17 years), 7411 seals made by using resin-based sealants (RB Sealants), modified glass ionomer sealants (RMGI) and compomer sealants have been analyzed. The best retention capacity of the material in time has been obtained from the use of RB Sealants compared to RMGI, demonstrating retention values much lower with partial loss of material at a distance of one year from the clinic. The compomers demonstrate retention values intermediates. The incidence of caries in a year is negligible for all sealants application. In terms of retention, resin

  2. Overview of NASA Glenn Seal Developments

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Proctor, Margaret P.; Dunlap, Patrick H., Jr.; Delgado, Irebert; DeMange, Jeffrey J.; Daniels, Christopher C.; Lattime, Scott B.

    2004-01-01

    Turbine engine studies have shown that reducing high pressure turbine (HPT) blade tip clearances will reduce fuel burn, lower emissions, retain exhaust gas temperature margin and increase range. Dr. Lattime presented the design and development status of a new Active Clearance Control Test rig aimed at demonstrating advanced ACC approaches and sensors. Mr. Melcher presented controls considerations for turbine active clearance control. Mr. Geisheimer of Radatech presented an overview of their microwave blade tip sensor technology. Microwave tip sensors show promise of operation in the extreme gas temperatures present in the HPT location. Mr. Justak presented an overview of non-contacting seal developments at Advanced Technologies Group. Dr. Braun presented investigations into a non-contacting finger seal under development by NASA GRC and University of Akron. Dr. Stango presented analytical assessments of the effects of flow-induced radial loads on brush seal behavior. Mr. Flaherty presented innovative seal and seal fabrication developments at FlowServ. Mr. Chappel presented abradable seal developments at Technetics. Dr. Daniels presented an overview of NASA GRC s acoustic seal developments. NASA is investigating the ability to harness high amplitude acoustic waves, possible through a new field of acoustics called Resonant Macrosonic Synthesis, to effect a non-contacting, low leakage seal. Dr. Daniels presented early results showing the ability to restrict flow via acoustic pressures. Dr. Athavale presented numerical results simulating the flow blocking capability of a pre-prototype acoustic seal.

  3. Mainshaft seals for small gas turbine engines

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P.; Lynwander, P.

    1974-01-01

    An experimental evaluation of mainshaft seals for small gas turbine engines was conducted with shaft speeds to 213 m/s (700 ft/sec), air pressures to 148 Newtons per square centimeter abs. (215 psia), and air temperatures to 412k(282 F). A radial face seal incorporating self-acting geometry for lift augmentation was evaluated. In addition, three conventional carbon seal types (face, circumferential segmented, and rotating ring) were run for comparison. Test results indicated that the conventional seals used in this evaluation may not be satisfactory in future advanced engines because of excessive air leakage. On the other hand, the self-acting face seal was shown to have the potential capability of limiting leakages to one-half that of the conventional face seals and one-fifth that of conventional ring seals. A 150-hour endurance test of the self-acting face seal was conducted.

  4. Titanium hermetic seals

    DOEpatents

    Brow, Richard K.; Watkins, Randall D.

    1995-07-04

    Titanium is prenitrided by being heated in a nitrogen environment under conditions which give rise to the formation of a titanium-nitride surface layer on the titanium. Titanium thus prenitrided may be used in electrical components which are hermetically sealed using silicate glasses and standard glass sealing techniques. According to the method of the invention, alkali volatilization and formation of deleterious interfacial silicide are inhibited.

  5. Titanium hermetic seals

    DOEpatents

    Brow, Richard K.; Watkins, Randall D.

    1995-01-01

    Titanium is prenitrided by being heated in a nitrogen environment under conditions which give rise to the formation of a titanium-nitride surface layer on the titanium. Titanium thus prenitrided may be used in electrical components which are hermetically sealed using silicate glasses and standard glass sealing techniques. According to the method of the invention, alkali volatilization and formation of deleterious interfacial silicide are inhibited.

  6. SEAL FOR HIGH SPEED CENTRIFUGE

    DOEpatents

    Skarstrom, C.W.

    1957-12-17

    A seal is described for a high speed centrifuge wherein the centrifugal force of rotation acts on the gasket to form a tight seal. The cylindrical rotating bowl of the centrifuge contains a closure member resting on a shoulder in the bowl wall having a lower surface containing bands of gasket material, parallel and adjacent to the cylinder wall. As the centrifuge speed increases, centrifugal force acts on the bands of gasket material forcing them in to a sealing contact against the cylinder wall. This arrangememt forms a simple and effective seal for high speed centrifuges, replacing more costly methods such as welding a closure in place.

  7. Internal coaxial cable seal system

    DOEpatents

    Hall, David R.; Sneddon, Cameron; Dahlgren, Scott Steven; Briscoe, Michael A.

    2006-07-25

    The invention is a seal system for a coaxial cable and is placed within the coaxial cable and its constituent components. A series of seal stacks including load ring components and elastomeric rings are placed on load bearing members within the coaxial cable sealing the annular space between the coaxial cable and an electrical contact passing there through. The coaxial cable is disposed within drilling components to transmit electrical signals between drilling components within a drill string. The seal system can be used in a variety of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

  8. Fissurectomy Combined with High-Dose Botulinum Toxin Is a Safe and Effective Treatment for Chronic Anal Fissure and a Promising Alternative to Surgical Sphincterotomy.

    PubMed

    Barnes, Thomas G; Zafrani, Zakhi; Abdelrazeq, Ayman S

    2015-10-01

    There is paucity of data on the long-term outcome of the combination of fissurectomy and botulinum toxin A injection for the management of chronic anal fissure. The aim of this study is to assess the safety, efficacy, and long-term outcome of the combination of fissurectomy and botulinum toxin A injection. This is a nonrandomized prospective cohort study. This study was conducted at a district general hospital in the United Kingdom. The cohort included all patients treated with fissurectomy and botulinum toxin A for chronic anal fissure between September 2008 and March 2012. The patients were treated with a combination of fissurectomy and botulinum toxin A injection. Symptomatic relief, fissure healing, complications, recurrence, and the need for further surgical intervention. One hundred and two patients received fissurectomy and botulinum toxin A injection for chronic anal fissure. At 12-week follow-up, 68 patients had resolution of symptoms and complete healing of chronic anal fissure, 29 patients had improvement of symptoms but incomplete healing and had further topical or botulinum toxin A treatment with subsequent complete healing. Ninety-five patients (93%) reported no postoperative complications. Seven patients reported a degree of incontinence in the immediate postoperative period. All reported normal continence at12-week follow-up. No local complications were observed or reported. At the mean follow-up of 33 months, there was no evidence of recurrence. Twelve-month follow-up was conducted via telephone interview only. This study is nonrandomized and did not examine the dose response of Botulinum Toxin A. Fissurectomy combined with high-dose botulinum toxin A is a safe, effective, and durable option for the management of chronic anal fissure and a promising alternative to surgical sphincterotomy.

  9. Energy conversion device with improved seal

    DOEpatents

    Miller, Gerald R.; Virkar, Anil V.

    1980-01-01

    An energy conversion device comprising an improved sealing member adapted to seal a cation-permeable casing to the remainder of the device. The sealing member comprises a metal substrate which (i) bears a nonconductive and corrosion resistant coating on the major surface to which said casing is sealed, and (ii) is corrugated so as to render it flexible, thereby allowing said member to move relative to said casing without cracking the seal therebetween. Corrugations may be circumferential, radial, or both radial and circumferential so as to form dimples. The corrugated member may be in form of a bellows or in a substantially flat form, such as a disc.

  10. Seal between metal and ceramic conduits

    DOEpatents

    Underwood, Richard Paul; Tentarelli, Stephen Clyde

    2015-02-03

    A seal between a ceramic conduit and a metal conduit of an ion transport membrane device consisting of a sealing surface of ceramic conduit, a sealing surface of ceramic conduit, a single gasket body, and a single compliant interlayer.

  11. High-pressure cryogenic seals for pressure vessels

    NASA Technical Reports Server (NTRS)

    Buggele, A. E.

    1977-01-01

    This investigation of the problems associated with reliably containing gaseous helium pressurized to 1530 bars (22 500 psi) between 4.2 K and 150 K led to the following conclusions: (1) common seal designs used in existing elevated-temperature pressure vessels are unsuitable for high-pressure cryogenic operation, (2) extrusion seal-ring materials such as Teflon, tin, and lead are not good seal materials for cryogenic high-pressure operation; and (3) several high-pressure cryogenic seal systems suitable for large-pressure vessel applications were developed; two seals required prepressurization, and one seal functioned repeatedly without any prepressurization. These designs used indium seal rings, brass or 304 stainless-steel anvil rings, and two O-rings of silicone rubber or Kel-F.

  12. Improved Seals for High Temperature Airframe Applications

    NASA Technical Reports Server (NTRS)

    DeMange, Jeffrey J.; Dunlap, Patrick H.; Steinetz, Bruce M.

    2006-01-01

    Current thermal barrier seals, such as those used on the Space Shuttle, are insufficient to fully meet the demands of future hypersonic vehicles and reentry spacecraft. Previous investigations have demonstrated limited usage temperatures, as evidenced by a decreased ability to maintain sealing effectiveness at high temperatures (i.e., inadequate resiliency). In order to improve resiliency at elevated temperatures, Rene 41 (Allvac) was substituted for Inconel X-750 (Special Metals Corp.) as the spring tube material in the existing seal design. A seal construction incorporating the Rene 41 spring tube was fabricated and tested against the baseline Inconel X-750 spring tube seal. Although resiliency improvements were not as dramatic as in previous tests with the spring tubes alone, seals incorporating the Rene 41 spring tube exhibited an average 20 percent resiliency enhancement up to 1750 F when compared to seals containing the Inconel spring tube. In addition, the seals with the Rene 41 spring tubes showed less reduction in resiliency as temperatures increased above 1200 F. Results also indicated the Saffil (Saffil Ltd.) insulation in the core of the seal contributed more to resiliency than previously thought. Leakage data did not demonstrate an improvement with the seal containing the Rene 41 spring tube. However, based upon resiliency results, one could reasonably expect the Rene 41 version of the seal to track gap openings over a wider range. Therefore it would exhibit lower leakage than the Inconel X-750 version as the seal gap opens during a typical mission.

  13. Sodium sulfur battery seal

    DOEpatents

    Topouzian, Armenag

    1980-01-01

    This invention is directed to a seal for a sodium sulfur battery in which a flexible diaphragm sealing elements respectively engage opposite sides of a ceramic component of the battery which separates an anode compartment from a cathode compartment of the battery.

  14. Rim seal for turbine wheel

    DOEpatents

    Glezer, Boris; Boyd, Gary L.; Norton, Paul F.

    1996-01-01

    A turbine wheel assembly includes a disk having a plurality of blades therearound. A ceramic ring is mounted to the housing of the turbine wheel assembly. A labyrinth rim seal mounted on the disk cooperates with the ceramic ring to seal the hot gases acting on the blades from the disk. The ceramic ring permits a tighter clearance between the labyrinth rim seal and the ceramic ring.

  15. Gas turbine sealing apparatus

    DOEpatents

    Marra, John Joseph; Wessell, Brian J.; Liang, George

    2013-03-05

    A sealing apparatus in a gas turbine. The sealing apparatus includes a seal housing apparatus coupled to a disc/rotor assembly so as to be rotatable therewith during operation of the gas turbine. The seal housing apparatus comprises a base member, a first leg portion, a second leg portion, and spanning structure. The base member extends generally axially between forward and aft rows of rotatable blades and is positioned adjacent to a row of stationary vanes. The first leg portion extends radially inwardly from the base member and is coupled to the disc/rotor assembly. The second leg portion is axially spaced from the first leg portion, extends radially inwardly from the base member, and is coupled to the disc/rotor assembly. The spanning structure extends between and is rigidly coupled to each of the base member, the first leg portion, and the second leg portion.

  16. Aerodynamic seal assemblies for turbo-machinery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bidkar, Rahul Anil; Wolfe, Christopher; Fang, Biao

    2015-09-29

    The present application provides an aerodynamic seal assembly for use with a turbo-machine. The aerodynamic seal assembly may include a number of springs, a shoe connected to the springs, and a secondary seal positioned about the springs and the shoe.

  17. Groundwater drainage from fissures as a source for lahars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, P. J.; Valentine, G. A.; Stauffer, P. H.

    One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have beenmore » heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. In this paper, we consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 10 3 m 3/m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. Finally, this simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.« less

  18. Fissure sealant materials: Wear resistance of flowable composite resins

    PubMed Central

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm2 and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm2of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics. PMID:27651887

  19. Groundwater drainage from fissures as a source for lahars

    DOE PAGES

    Johnson, P. J.; Valentine, G. A.; Stauffer, P. H.; ...

    2018-03-22

    One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have beenmore » heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. In this paper, we consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 10 3 m 3/m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. Finally, this simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.« less

  20. Fissure sealant materials: Wear resistance of flowable composite resins.

    PubMed

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.