Sample records for occlusal splint therapy

  1. Interdisciplinary treatment of bruxism with an occlusal splint and cognitive behavioral therapy.

    PubMed

    Trindade, Marilene; Orestes-Cardoso, Silvana; de Siqueira, Teresa Cristina

    2015-01-01

    The etiology of bruxism is associated with exogenous factors, such as occlusal interference, stress, and anxiety, as well as endogenous factors involving neurotransmitters of the basal ganglia. Due to the multifactorial etiology of bruxism, interdisciplinary treatment involving professionals from different healthcare fields has been proposed. The aim of the present study was to compare 2 groups of patients with bruxism (11 in each group) treated with either an occlusal splint combined with cognitive behavioral therapy or an occlusal splint alone. Surface electromyography of the masseter and anterior temporal muscles at rest was performed before and after treatment. The mean amplitude of activity of all muscles was lower after treatment, except for the right anterior temporal muscle in the group treated with an occlusal splint alone. Mean amplitudes were greater in the anterior temporal muscles than in the masseter muscles. Significantly greater improvement was found in the group exposed to cognitive behavioral therapy (P < 0.05; analysis of variance and Student t tests). Therefore, the combination of occlusal splint and psychological therapy was more effective at achieving muscle relaxation than occlusal splint use alone.

  2. Dentists' knowledge of occlusal splint therapy for bruxism and temporomandibular joint disorders.

    PubMed

    Candirli, C; Korkmaz, Y T; Celikoglu, M; Altintas, S H; Coskun, U; Memis, S

    2016-01-01

    The aim of this study was to investigate dentist's approaches to the use of splint therapy for myofascial pain, bruxism, and temporomandibular joint (TMJ) disorders and to assessment of treatment modalities. A 12-item questionnaire was developed to determine dentists' knowledge of TMJ disorders and approaches for occlusal splint treatments. The researchers spoke with each dentist included in the study at his/her clinic or by telephone to assess their immediate knowledge and approach to the TMJ disorders. Chi-squared test was performed to analyze the values. The confidence interval was set as 95%. A total of 370 dentists working in Turkey were participated in this study. The most common splint application reason for occlusal splint treatment was bruxism (77.8%) while TMJ pain was very rare (%1.4). The use of hard splint ratios for 0-5 years of professional experience was 57.0%, 42.4.0%, and 26.8% for the experience of 5-15 years and over 15 years groups, respectively (P < 0.001). While the dentists' with sufficient knowledge soft splint application rates were 11.6%, hard splint application rates were 43.4% for the dentists with sufficient knowledge. Occlusion adjustment rate of dentists who practice in all three groups was under 16.0%. The knowledge of the dentists about TMJ disorders and occlusal splint therapy were found to be insufficient. Their knowledge decreased with increasing experience.

  3. Occlusal stabilization splint therapy in orofacial pain and tension-type headache.

    PubMed

    Kostrzewa-Janicka, J; Mierzwinska-Nastalska, E; Rolski, D; Szczyrek, P

    2013-01-01

    Studies suggest an association between orofacial pain, accompanying temporomandibular disorders of myogenous origin, and headache, especially its tension-type. The occlusal appliance therapy is one of the options for the treatment of orofacial pain due to masticatory muscles tenderness. The aim of the present study was to assess the effectiveness of occlusal stabilization splint therapy in myofascial pain and tension-type headache in patients with sleep-disordered breathing. Forty three such patients were enrolled into the study group. The patients were treated with stabilization occlusal splint of vertical thickness at vertical jaw separation, established individually for each patient using a cephalometric analysis. The intensity of orofacial pain (numeric rating scale) and headache (analog rating scale), frequency of headache (%), and jaw qualitative function were assessed at baseline and after 2 and 6 months. Medians of headache and orofacial pain intensity were reduced after 6 months of treatment compared with baseline: 6.0 vs. 2.0 (p < 0.0001) and 6.0 vs. 1.0 (p < 0.0001), respectively. Pain decreased below 3 score points in 61.8 % of the patients with headache (p = 0.23) and in 85.3 % of patients with orofacial pain (p < 0.0001). Overall, the improvement in both signs and symptoms of orofacial pain was observed 81.4 % of patients after using occlusal stabilization splint for 6 months. We conclude that occlusal stabilization splint was effective in reducing painful symptoms of temporomandibular disorders of myogenous origin, a frequent feature of sleep disordered breathing.

  4. Soft versus hard occlusal splint therapy in the management of temporomandibular disorders (TMDs)

    PubMed Central

    Seifeldin, Sameh A; Elhayes, Khaled A.

    2015-01-01

    Aim To compare between soft and hard occlusal splint therapy for the management of myofacial pain dysfunction (MPD) or internal derangement (ID) of the temporomandibular joint (TMJ) with reciprocal clicking. Patients and methods This study included 50 patients (age range: 24–47 years) who had been diagnosed with MPD or ID of the TMJ in the form of reciprocal clicking. Patients were divided into two groups. They were treated for 4 months with either a vacuum-formed soft occlusal splint constructed from 2-mm-thick elastic rubber sheets (soft splint group) or a hard flat occlusal splint fabricated from transparent acrylic resin (hard splint group). Monthly follow-up visits were performed during the treatment period. Before treatment and 1, 2, 3 and 4 months after treatment, the dentist measured all parameters of TMJ function (pain visual analog scores, tenderness of masticatory muscles, clicking and tenderness of the TMJ, and range of mouth opening). Results All parameters of TMJ function showed significant improvement in both groups during the follow-up period, with a statistically significant difference between the two groups at the 4-month follow-up visit. Conclusions Both forms of occlusal splints (soft and hard) improved TMJ symptoms in patients with MPD or ID of the TMJ. However, the soft occlusal splints exhibited superior results after 4 months of use. PMID:26644756

  5. Occlusal splint versus modified nociceptive trigeminal inhibition splint in bruxism therapy: a randomized, controlled trial using surface electromyography.

    PubMed

    Dalewski, B; Chruściel-Nogalska, M; Frączak, B

    2015-12-01

    An occlusal splint and a modified nociceptive trigeminal inhibition splint (AMPS, anterior deprogrammer, Kois deprogrammer, Lucia jig, etc.) are commonly and quite frequently used in the treatment of masticatory muscle disorders, although their sustainable and long-lasting effect on these muscles' function is still not very well known. Results of scant surface electromyography studies in patients with temporomandibular disorders have been contradictory. The aim of this study was to evaluate both devices in bruxism therapy; EMG activity levels during postural activity and maximum voluntary contraction of the superficial temporal and masseter muscles were compared before and after 30 days of treatment. Surface electromyography of the examined muscles was performed in two groups of bruxers (15 patients each). Patients in the first group used occlusal splints, while those in the second used modified nociceptive trigeminal inhibition splints. The trial was randomized, controlled and semi-blind. Neither device affected the asymmetry index or postural activity/maximum voluntary contraction ratio after 1 month of treatment. Neither the occlusal nor the nociceptive trigeminal inhibition splint showed any significant influence on the examined muscles. Different scientific methods should be considered in clinical applications that require either direct influence on the muscles' bioelectrical activity or a quantitative measurement of the treatment quality. © 2015 Australian Dental Association.

  6. Effects of massage therapy and occlusal splint therapy on mandibular range of motion in individuals with temporomandibular disorder: a randomized clinical trial.

    PubMed

    Gomes, Cid André Fidelis de Paula; Politti, Fabiano; Andrade, Daniel Ventura; de Sousa, Dowglas Fernando Magalhães; Herpich, Carolina Marciela; Dibai-Filho, Almir Vieira; Gonzalez, Tabajara de Oliveira; Biasotto-Gonzalez, Daniela Aparecida

    2014-01-01

    The purpose of this study was to investigate the effects of massage therapy compared with occlusal splint therapy on mandibular range of motion (ROM) in individuals with temporomandibular disorder (TMD) and compare the results with ROM obtained in a group of individuals without this disorder. A blinded randomized clinical trial was conducted. Twenty-eight volunteers with TMD were randomly distributed into either a massage therapy group or an occlusal splint group. Both treatments were provided for 4 weeks. Fourteen individuals without TMD were consecutively allocated to a comparison group. Fonseca anamnestic index was used to characterize TMD and allocate the volunteers to either of the intervention groups or asymptomatic comparison group. Mandibular ROM was evaluated before and after treatment using a digital caliper. Two-way repeated-measures analysis of variance with a post hoc Bonferroni testing was used for intergroup and intragroup comparisons (level of significance was set to 5%). Cohen d was used to calculate the effect size. In the intragroup analysis, significant increases in ROM were found for all measures in both the massage and occlusal splint groups (P < .05). A small to moderate clinical effect of treatment with the occlusal splint was found regarding right and left lateral excursion in comparison with the massage therapy and asymptomatic comparison groups (0.2 therapy on the masticatory muscles and the use of an occlusal splint lead to an increase in mandibular ROM similar to that of the asymptomatic comparison group with regard to maximum active mouth opening and both right and left excursion in individuals with TMD. © 2013. Published by National University of Health Sciences All rights reserved.

  7. Effects of massage therapy and occlusal splint therapy on electromyographic activity and the intensity of signs and symptoms in individuals with temporomandibular disorder and sleep bruxism: a randomized clinical trial.

    PubMed

    Gomes, Cid André Fidelis de Paula; El Hage, Yasmin; Amaral, Ana Paula; Politti, Fabiano; Biasotto-Gonzalez, Daniela Aparecida

    2014-01-01

    Temporomandibular disorder (TDM) is the most common source of orofacial pain of a non-dental origin. Sleep bruxism is characterized by clenching and/or grinding the teeth during sleep and is involved in the perpetuation of TMD. The aim of the present study was to investigate the effects of massage therapy, conventional occlusal splint therapy and silicone occlusal splint therapy on electromyographic activity in the masseter and anterior temporal muscles and the intensity of signs and symptoms in individuals with severe TMD and sleep bruxism. Sixty individuals with severe TMD and sleep bruxism were randomly distributed into four treatment groups: 1) massage group, 2) conventional occlusal splint group, 3) massage + conventional occlusal splint group and 4) silicone occlusal splint group. Block randomization was employed and sealed opaque envelopes were used to conceal the allocation. Groups 2, 3 and 4 wore an occlusal splint for four weeks. Groups 1 and 3 received three weekly massage sessions for four weeks. All groups were evaluated before and after treatment through electromyographic analysis of the masseter and anterior temporal muscles and the Fonseca Patient History Index. The Wilcoxon test was used to compare the effects of the different treatments and repeated-measures ANOVA was used to determine the intensity of TMD. The inter-group analysis of variance revealed no statistically significant differences in median frequency among the groups prior to treatment. In the intra-group analysis, no statistically significant differences were found between pre-treatment and post-treatment evaluations in any of the groups. Group 3 demonstrated a greater improvement in the intensity of TMD in comparison to the other groups. Massage therapy and the use of an occlusal splint had no significant influence on electromyographic activity of the masseter or anterior temporal muscles. However, the combination of therapies led to a reduction in the intensity of signs and

  8. Effect of simultaneous therapy of arthrocentesis and occlusal splints on temporomandibular disorders: anterior disc displacement without reduction

    PubMed Central

    Lee, Hye-Sung; Baek, Hyun-Su; Song, Dong-Suk; Kim, Hee-Chul; Kim, Hyo-Geun; Kim, Bok-Joo; Kim, Myung-Soo; Shin, Sang-Hoon; Jung, Sung-Hee

    2013-01-01

    Objectives This study sought to evaluate the effect of simultaneous application of arthrocentesis and occlusal splint. Materials and Methods A retrospective study of 43 patients (3 males, 40 females) whose symptoms had improved was conducted at the Department of Oral and Maxillofacial Surgery, Dong-A University Hospital between 2008 and 2010. Subjects were divided into three groups: Group A (17 patients with arthrocentesis and occlusal splints simultaneously applied), Group B (13 patients whose symptoms did not improve with occlusal splints, undergoing arthrocentesis after occlusal splint use for 8 weeks), and Group C (13 patients that only used occlusal splints). We compared these groups in maximum comfortable opening (MCO) and the visual analogue scale of pain and noise. Follow-up was performed at 1 week, 1 month, 3 months, and 6 months. Results The improvement of symptoms was noted in all three groups, but Group A had a quicker improvement than the other groups, in terms of pain reduction and MCO increases. Conclusion The simultaneous application of arthrocentesis and occlusal splints can reduce patient discomfort more quickly. PMID:24471012

  9. Effect of simultaneous therapy of arthrocentesis and occlusal splints on temporomandibular disorders: anterior disc displacement without reduction.

    PubMed

    Lee, Hye-Sung; Baek, Hyun-Su; Song, Dong-Suk; Kim, Hee-Chul; Kim, Hyo-Geun; Kim, Bok-Joo; Kim, Myung-Soo; Shin, Sang-Hoon; Jung, Sung-Hee; Kim, Chul-Hoon

    2013-02-01

    This study sought to evaluate the effect of simultaneous application of arthrocentesis and occlusal splint. A retrospective study of 43 patients (3 males, 40 females) whose symptoms had improved was conducted at the Department of Oral and Maxillofacial Surgery, Dong-A University Hospital between 2008 and 2010. Subjects were divided into three groups: Group A (17 patients with arthrocentesis and occlusal splints simultaneously applied), Group B (13 patients whose symptoms did not improve with occlusal splints, undergoing arthrocentesis after occlusal splint use for 8 weeks), and Group C (13 patients that only used occlusal splints). We compared these groups in maximum comfortable opening (MCO) and the visual analogue scale of pain and noise. Follow-up was performed at 1 week, 1 month, 3 months, and 6 months. The improvement of symptoms was noted in all three groups, but Group A had a quicker improvement than the other groups, in terms of pain reduction and MCO increases. The simultaneous application of arthrocentesis and occlusal splints can reduce patient discomfort more quickly.

  10. Efficacy of biofeedback therapy via a mini wireless device on sleep bruxism contrasted with occlusal splint: a pilot study

    PubMed Central

    Gu, WeiPing; Yang, Jie; Zhang, FeiMin; Yin, XinMin; Wei, XiaoLong; Wang, Chen

    2015-01-01

    Abstract The putative causes of bruxism are multifactorial and there are no definite measures for bruxism management. The aim of this study was to evaluate the efficacy of biofeedback therapy on sleep bruxism, compared with occlusal splint. Twenty-four volunteers with sleep bruxism were divided into two groups: the GTB group that were treated with biofeedback therapy (n  = 12) and the GTO group that were treated with occlusal splint (n  = 12). A mini pressure sensor integrated with a monitoring circuit by use of a maxillary biofeedback splint was fabricated. To foster the relaxation of the masticatory muscles and the nervous system, the wireless device received signals from bruxism events and vibrations alerted the bruxer when the threshold was exceeded. Total episodes and average duration of bruxism events during 8 hours of sleep were analyzed with the monitoring program (TRMY1.0). After 6 and 12 weeks, the episodes (P  =  0.001) and duration (P < 0.05) in the GTB group declined dramatically. In contrast, there were no significant differences in the GTO group after the treatment (P > 0.05). Furthermore, the episodes had significant differences between the GTB group and the GTO group after the same period of treatment (P  =  0.000). The results suggest that biofeedback therapy may be an effective and convenient measure for mild bruxers, when compared with occlusal splint therapy. The mini wireless biofeedback method may be of value for the diagnosis and management of bruxism in the future. PMID:25859272

  11. Laser Therapy and Occlusal Stabilization Splint for Temporomandibular Disorders in Patients With Fibromyalgia Syndrome: A Randomized, Clinical Trial.

    PubMed

    Molina-Torres, Guadalupe; Rodríguez-Archilla, Alberto; Matarán-Peñarrocha, Guillermo; Albornoz-Cabello, Manuel; Aguilar-Ferrándiz, María Encarnación; Castro-Sánchez, Adelaida María

    2016-09-01

    Context • Patients with fibromyalgia syndrome (FMS) report frequent and severe symptoms from temporomandibular disorders (TMDs). The appropriate treatment of TMDs remains controversial. No studies have occurred on the efficacy of therapy with a laser or an occlusal stabilization splint in the treatment of TMDs in patients with FMS. Objective • The study intended to investigate the therapeutic effects of laser therapy and of an occlusal stabilization splint for reducing pain and dysfunction and improving the quality of sleep in patients with TMDs and FMS. Design • The research team designed a single-blinded, randomized clinical trial. Setting • The study took place in the research laboratory at the University of Granada (Granada, Spain). Participants • Participants were 58 women and men who had been diagnosed with FMS and TMDs and who were referred from the clinical setting. Intervention • Participants were randomly assigned to the occlusal-splint or the laser group. The laser group received a treatment protocol in which laser therapy was applied to the participant's tender points, and the occlusal-splint group underwent a treatment protocol in which an occlusal stabilization splint was used. Both groups underwent treatment for 12 wk. Outcomes Measures • Pain intensity, widespread pain, quality of sleep, severity of symptoms, active and passive mouth opening, and joint sounds were assessed in both groups at baseline and after the last intervention. The measurements used were (1) a visual analogue scale (VAS), (2) the Widespread Pain Index (WPI), (3) the Symptom Severity Scale (SSS), (4) the Patient's Global Impression of Change (PGIC), (5) the Pittsburgh Quality of Sleep Questionnaire Index (PSQI), (6) an assessment of the number of tender points, (7) a measurement of the active mouth opening, (8) a measurement of the vertical overlap of the incisors, and (9) the measurement of joint sounds during mouth opening and closing. Results • The group X time

  12. Occlusal splints for treating sleep bruxism (tooth grinding).

    PubMed

    Macedo, C R; Silva, A B; Machado, M A; Saconato, H; Prado, G F

    2007-10-17

    Sleep bruxism is an oral activity characterised by teeth grinding or clenching during sleep. Several treatments for sleep bruxism have been proposed such as pharmacological, psychological, and dental. To evaluate the effectiveness of occlusal splints for the treatment of sleep bruxism with alternative interventions, placebo or no treatment. We searched the Cochrane Oral Health Group's Trials Register (to May 2007); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, Issue 1); MEDLINE (1966 to May 2007); EMBASE (1980 to May 2007); LILACS (1982 to May 2007); Biblioteca Brasileira de Odontologia (1982 to May 2007); Dissertation, Theses and Abstracts (1981 to May 2007); and handsearched abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. We selected randomised or quasi-randomised controlled trials (RCTs), in which splint therapy was compared concurrently to no treatment, other occlusal appliances, or any other intervention in participants with sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCTs were identified. Twenty-four trials were excluded. Five RCTs were included. Occlusal splint was compared to: palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant differences between the occlusal splint and control groups were found in the meta-analyses. There is not sufficient evidence to state that the occlusal splint is

  13. The effectiveness of occlusal splints for sleep bruxism.

    PubMed

    Jagger, Robert

    2008-01-01

    Searches were made using the Cochrane Oral Health Group's Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Embase, LILACS (Latin American & Caribbean Health Sciences Literature), Biblioteca Brasileira de Odontologia, and Dissertations, Theses and Abstracts. Hand searches were made of abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. Randomised controlled trials (RCT) or quasi-RCT were chosen that compared splint therapy concurrently with no treatment, other occlusal appliances, or any other intervention in participants who had sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCT were identified of which five were eventually included. In these, use of an occlusal splint was compared with palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant difference between the occlusal splint and control groups were found in meta-analysis. There is not enough evidence to state that the occlusal splint is effective for treating sleep bruxism. Indication of its use is questionable with regard to sleep outcomes, but there may be some benefit with regard to tooth wear. This systematic review suggests the need for further investigation in more controlled RCT that pay attention to method of allocation, outcome assessment, large sample size, and sufficient duration of followup. The study design must be parallel in order to eliminate

  14. COMPARATIVE EVALUATION OF THE EFFICACY OF OCCLUSAL SPLINTS FABRICATED IN CENTRIC RELATION OR MAXIMUM INTERCUSPATION IN TEMPOROMANDIBULAR DISORDERS PATIENTS

    PubMed Central

    Hamata, Marcelo Matida; Zuim, Paulo Renato Junqueira; Garcia, Alicio Rosalino

    2009-01-01

    Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous origin and bruxism were divided into 2 groups treated with splints in maximum intercuspation (I) or centric relation (II). Clinical, electrognathographic and electromyographic examinations were performed before and 3 months after therapy. Data were analyzed by the Student's t test. Differences at 5% level of probability were considered statistically significant. There was a remarkable reduction in pain symptomatology, without statistically significant differences (p>0.05) between the groups. There was mandibular repositioning during therapy, as demonstrated by the change in occlusal contacts on the splints. Electrognathographic examination demonstrated a significant increase in maximum left lateral movement for group I and right lateral movement for group II (p<0.05). There were no significant differences (p>0.05) in the electromyographic activities at rest after utilization of both splints. In conclusion, both occlusal splints were effective for pain control and presented similar action. The results suggest that maximum intercuspation may be used for fabrication of occlusal splints in patients with occlusal stability without large discrepancies between centric relation and maximum intercuspation. Moreover, this technique is simpler and less expensive. PMID:19148403

  15. Changes in cortical activation in craniomandibular disorders during splint therapy - a single subject fMRI study.

    PubMed

    Lickteig, Rita; Lotze, Martin; Lucas, Christian; Domin, Martin; Kordass, Bernd

    2012-03-20

    There is some controversial discussion within the therapy of craniomandibular disorders (CMDs) about the mode of action of occlusal splints. Here we present a case report on one CMD-patient measuring cerebral activation changes with functional magnetic resonance imaging (fMRI) before and after therapy with a stabilization splint. Wearing the Michigan splint for 11 nights and partially days resulted in substantial pain relief and changes in occlusal movement performance. Cerebral activation during occlusion was decreased after therapy (PRE-POST) in bilateral sensorimotor regions but also additional areas such as left posterior insula, right superior temporal cortex and bilateral occipital lobe. During the first usage of the splint in the scanner (PRE) increased activation in the left dorsolateral prefrontal lobe (BA 9) was observed. After splint training occlusion with the splint compared to without a splint increasingly involved the left superior parietal lobe (BA 7, POST). Whereas BA 9 might be associated with increasing working memory load due to the manipulation with an unusual object, the BA 7 activation in the POST session might document increased sensorimotor interaction after getting used to the splint. Our findings indicate that wearing an occlusion splint triggers activation in parietal sensorimotor integration areas, also observed after long periods of sensorimotor training. These additional recourses might improve coordination and physiological handling of the masticatory system. Copyright © 2011. Published by Elsevier GmbH.

  16. Influence of stabilization occlusal splint on craniocervical relationships. Part I: Cephalometric analysis.

    PubMed

    Moya, H; Miralles, R; Zuñiga, C; Carvajal, R; Rocabado, M; Santander, H

    1994-01-01

    This study was conducted in order to determine the effect of an occlusal splint on craniocervical relationships, in subjects with muscle spasms in the sternocleidomastoid and trapezius muscles. A full-arch maxillary stabilization occlusal splint was made for each of the 15 subjects. Two lateral craniocervical radiographs were taken for each subject, with and without an occlusal splint. Cephalometric analysis showed that the splint caused a significant extension of the head on the cervical spine. There was also a significant decrease in the cervical spine lordosis in the first, second and third cervical segment. These cervical changes could be a compensation mechanism caused by the extension of the cranium on the upper cervical spine. The change in the curvature implies that it is necessary to periodically evaluate the changes occurring in the craniocervical relationships after the occlusal splint has been inserted.

  17. Towards an optimal therapy strategy for myogenous TMD, physiotherapy compared with occlusal splint therapy in an RCT with therapy-and-patient-specific treatment durations.

    PubMed

    van Grootel, Robert J; Buchner, Rob; Wismeijer, Daniël; van der Glas, Hilbert W

    2017-02-10

    Temporomandibular Disorders (TMD) may be characterized by pain and restricted jaw movements. In the absence of somatic factors in the temporomandibular joint, mainly myogenous, psychobiological, and psychosocial factors may be involved in the aetiology of myogenous TMD. An occlusal appliance (splint) is commonly used as a basic therapy of the dental practice. Alternatively, a type of physiotherapy which includes, apart from massage of sore muscles, aspects of cognitive-behavioural therapy might be a basic therapy for myogenous TMD. Treatment outcome of physiotherapy (Ph-Tx) was evaluated in comparison to that of splint therapy (Sp-Tx), using the index Treatment Duration Control (TDC) that enabled a randomized controlled trial with, comparable to clinical care, therapy-and-patient-specific treatment durations. Seventy-two patients were randomly assigned to either Ph-Tx or Sp-Tx, with an intended treatment duration between 10 and 21 or 12 and 30 weeks respectively. Using TDC, the clinician controlled treatment duration and the number of visits needed. A blinded assessor recorded anamnestic and clinical data to determine TDC-values following treatment and a 1-year follow-up, yielding success rate (SR) and effectiveness (mean TDC) as treatment outcomes. Cohen's d, was determined for pain intensity. Overall SR for stepped-care was assessed in a theoretical model, i.e. a second of the two studied therapies was applied if the first treatment was unsuccessful, and the effect of therapy sequence and difference in success rates was examined. SR and effectiveness were similar for Ph-Tx and Sp-Tx (long-term SR: 51-60%; TDC: -0.512- -0.575). Cohen's d was 0.86 (Ph-Tx) and 1.39 (Sp-Tx). Treatment duration was shorter for Ph-Tx (on average 10.4 weeks less; p < 0.001). Sp-Tx needed 7.1 less visits (p < 0.001). Physiotherapy may be preferred as initial therapy over occlusal splint therapy in stepped-care of myogenous TMD. With a similar SR and effectiveness, physiotherapy

  18. Combined occlusal and pharmacological therapy in the treatment of temporo-mandibular disorders.

    PubMed

    Inchingolo, F; Tatullo, M; Marrelli, M; Inchingolo, A M; Tarullo, A; Inchingolo, A D; Dipalma, G; Podo Brunetti, S; Tarullo, A; Cagiano, R

    2011-11-01

    Aim of the present work is to assess the effectiveness of a scientific protocol built up to relieve pain in chronic temporo-mandibular disorders (TMD) using Michigan splint together with a pharmacological therapy compared to the traditional occlusal therapy by Michigan splint alone. 35 adult patients, with signs and symptoms of TMD lasting more than 6 months, were enrolled into this study and divided into two groups: the first receiving occlusal therapy by Michigan splint and pharmacological therapy with Delorazepam and Thiocolchicoside, while the second receiving occlusal therapy by Michigan splint and "placebo" administration. The comparisons between the two experimental groups were assessed using a 5 steps visual-analogue scale (V.A.S.). The outcomes from the experimental groups were statistically compared resulting significantly different with an improvement or disappearance of signs and symptoms in the treated group with respect to the placebo group at 12 and 18 months from the beginning of the experiment (p < 0.001).

  19. Effect of occlusal splint therapy on maximum bite force in individuals with moderate to severe attrition of teeth.

    PubMed

    Jain, Veena; Mathur, Vijay Prakash; Abhishek, Kumar; Kothari, Mohit

    2012-10-01

    The purpose of the pilot study was to determine the effect of restoring lost occlusal vertical dimension (OVD) due to attrition on maximum bite force in humans. A total of 124 subjects in age range of 25-40 years, with moderate to severe attrition, having full complement of teeth were screened according to inclusion and exclusion criteria. After consent, occlusal vertical dimension was assessed by employing mechanical and physiological methods in the experimental group and a maxillary canine guided hard splint was fabricated for each subjects fulfilling inclusion criteria and with positive consent (78). Bite force in experimental group was measured before, immediately after delivery of splint and subsequently at an interval of four, eight, and twelve weeks. Due loss during follow up, only 50 subjects could be available for bite force recording till 12 weeks. Bite force of age, gender, height and weight matched controls with no signs of attrition was also measured for comparison. Bite force of the experimental group was found to be significantly less than the matched controls (P=0.000) initially. After delivery of splint, bite force values increased progressively till twelve weeks. However comparison of bite force values of experimental group with control group showed no significant difference at end of eight (P=0.008) and twelve weeks (P=0.162). It was concluded that maximum bite force increases with restoration of lost vertical using splint therapy. A time period of 8-12 weeks is required to restore the maximum bite force value approximately similar to matched controls. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Controlled assessment of the efficacy of occlusal stabilization splints on sleep bruxism.

    PubMed

    van der Zaag, Jacques; Lobbezoo, Frank; Wicks, Darrel J; Visscher, Corine M; Hamburger, Hans L; Naeije, Machiel

    2005-01-01

    To assess the efficacy of occlusal stabilization splints in the management of sleep bruxism (SB) in a double-blind, parallel, controlled, randomized clinical trial. Twenty-one participants were randomly assigned to an occlusal splint group (n = 11; mean age = 34.2 +/- 13.1 years) or a palatal splint (ie, an acrylic palatal coverage) group (n = 10; mean age = 34.9 +/- 11.2 years). Two polysomnographic recordings that included bilateral masseter electromyographic activity were made: one prior to treatment, the other after a treatment period of 4 weeks. The number of bruxism episodes per hour of sleep (Epi/h), the number of bursts per hour (Bur/h), and the bruxism time index (ie, the percentage of total sleep time spent bruxing) were established as outcome variables at a 10% maximum voluntary contraction threshold level. A general linear model was used to test both the effects between splint groups and within the treatment phase as well as their interaction for each outcome variable. Neither occlusal stabilization splints nor palatal splints had an influence on the SB outcome variables or on the sleep variables measured on a group level. In individual cases, variable outcomes were found: Some patients had an increase (33% to 48% of the cases), while others showed no change (33% to 48%) or a decrease (19% to 29%) in SB outcome variables. The absence of significant group effects of splints in the management of SB indicates that caution is required when splints are indicated, apart from their role in the protection against dental wear. The application of splints should therefore be considered at the individual patient level.

  1. A digital process for additive manufacturing of occlusal splints: a clinical pilot study

    PubMed Central

    Salmi, Mika; Paloheimo, Kaija-Stiina; Tuomi, Jukka; Ingman, Tuula; Mäkitie, Antti

    2013-01-01

    The aim of this study was to develop and evaluate a digital process for manufacturing of occlusal splints. An alginate impression was taken from the upper and lower jaws of a patient with temporomandibular disorder owing to cross bite and wear of the teeth, and then digitized using a table laser scanner. The scanned model was repaired using the 3Data Expert software, and a splint was designed with the Viscam RP software. A splint was manufactured from a biocompatible liquid photopolymer by stereolithography. The system employed in the process was SLA 350. The splint was worn nightly for six months. The patient adapted to the splint well and found it comfortable to use. The splint relieved tension in the patient's bite muscles. No sign of tooth wear or significant splint wear was detected after six months of testing. Modern digital technology enables us to manufacture clinically functional occlusal splints, which might reduce costs, dental technician working time and chair-side time. Maximum-dimensional errors of approximately 1 mm were found at thin walls and sharp corners of the splint when compared with the digital model. PMID:23614943

  2. Side effects of stabilization occlusal splints: a report of three cases and literature review.

    PubMed

    Magdaleno, Fernando; Ginestal, Eduardo

    2010-04-01

    Stabilization splints are frequently used for the treatment of temporomandibular disorders (TMD) and bruxism, despite the fact that little is known about their mechanism of action or the precise conditions under which they can be recommended. Moreover, information about their possible adverse effects, which in the majority of cases include occlusal modifications of little clinical relevance, is scarce. On occasions, these splints can provoke severe occlusal alterations and other complications, which are rarely alluded to in the literature. Here presented in this paper are three case reports in which part-time stabilization splints led to irreversible occlusal alterations and a discussion of the relevant clinical implications. Such splints are reported to negatively affect the condyle-disk relation in patients who exhibit disk displacement with reduction and to modify breathing features in patients with obstructive sleep apnea, although further studies are required to unequivocally demonstrate these findings. Finally, the splint seems to modify peripheral information at the level of the Central Nervous System, leading to modifications in corporal postural tone. The clinical repercussions of such alterations are currently poorly understood. It is our hope that future research will throw fresh light on these important topics.

  3. RapidSplint: virtual splint generation for orthognathic surgery - results of a pilot series.

    PubMed

    Adolphs, Nicolai; Liu, Weichen; Keeve, Erwin; Hoffmeister, Bodo

    2014-01-01

    Within the domain of craniomaxillofacial surgery, orthognathic surgery is a special field dedicated to the correction of dentofacial anomalies resulting from skeletal malocclusion. Generally, in such cases, an interdisciplinary orthodontic and surgical treatment approach is required. After initial orthodontic alignment of the dental arches, skeletal discrepancies of the jaws can be corrected by distinct surgical strategies and procedures in order to achieve correct occlusal relations, as well as facial balance and harmony within individualized treatment concepts. To transfer the preoperative surgical planning and reposition the mobilized dental arches with optimal occlusal relations, surgical splints are typically used. For this purpose, different strategies have been described which use one or more splints. Traditionally, these splints are manufactured by a dental technician based on patient-specific dental casts; however, computer-assisted technologies have gained increasing importance with respect to preoperative planning and its subsequent surgical transfer. In a pilot study of 10 patients undergoing orthognathic corrections by a one-splint strategy, two final occlusal splints were produced for each patient and compared with respect to their clinical usability. One splint was manufactured in the traditional way by a dental technician according to the preoperative surgical planning. After performing a CBCT scan of the patient's dental casts, a second splint was designed virtually by an engineer and surgeon working together, according to the desired final occlusion. For this purpose, RapidSplint, a custom-made software platform, was used. After post-processing and conversion of the datasets into .stl files, the splints were fabricated by the PolyJet procedure using photo polymerization. During surgery, both splints were inserted after mobilization of the dental arches then compared with respect to their clinical usability according to the occlusal fitting. Using

  4. Comparison of wear between occlusal splint materials and resin composite materials.

    PubMed

    Reyes-Sevilla, M; Kuijs, R H; Werner, A; Kleverlaan, C J; Lobbezoo, F

    2018-07-01

    Tooth wear in bruxing patients often results in a need for treatment with composite restorations. In some cases, bruxing patients receive an occlusal splint as a protective means as well. However, the wear between these opposing materials has not been investigated yet. The aim of this in vitro study was to assess the wear of different splint materials against resin composite materials. A two-body wear test was conducted using the ACTA wear machine. The materials selected for this study were three composites used for direct restorations (Filtek Z250, CLEARFIL AP-X, and Filtek Supreme XT) and four occlusal splints materials, viz. a polyamide resin (ThermoSens) an conventional (hand-processed), milled and printed polymethylmethacrylate (PMMA). As antagonistic materials, stainless steel, Filtek Supreme XT and CLEARFIL AP-X were used. The wear rate of the seven materials was determined after 200 000 cycles, using a profilometry. The rates were analysed using two-way ANOVA and post hoc Tukey's tests. The wear rates were significantly higher for the conventional and milled PMMA materials than for all other materials (P < .001). The wear rates of printed PMMA and the polyamide resin were comparable to composite wear rates. The antagonist materials have minor or no influence on the amount of wear of the various splint materials (P < .001). In conclusion, different splint materials yielded different wear rates for all antagonist materials tested. Keeping in mind that this study is an experimental in vitro study, this finding enables practitioners to choose the splint material necessary according to their patients' needs. © 2018 John Wiley & Sons Ltd.

  5. Stabilisation splint therapy for temporomandibular pain dysfunction syndrome.

    PubMed

    Al-Ani, M Z; Davies, S J; Gray, R J M; Sloan, P; Glenny, A M

    2004-01-01

    Pain dysfunction syndrome (PDS) is the most common temporomandibular disorder (TMD). There are many synonyms for this condition including facial arthromylagia, TMJ dysfunction syndrome, myofacial pain dysfunction syndrome, craniomandibular dysfunction and myofacial pain dysfunction. The aetiology of PDS is multifactorial and many different therapies have been advocated. To establish the effectiveness of stabilisation splint therapy in reducing symptoms in patients with pain dysfunction syndrome. Electronic databases (including the Cochrane Oral Health Group's Trials Register; the Cochrane Central Register of Controlled Trials (CENTRAL); The Cochrane Library Issue 2, 2003; MEDLINE (1966 to June 2001); EMBASE (1966 to June 2001)) were searched. Handsearching of relevant journals was undertaken and reference lists of included studies screened. Experts in the field were contacted to identify unpublished articles. There was no language restriction. Randomised or quasi-randomised controlled trials (RCTs), in which splint therapy was compared concurrently to no treatment, other occlusal appliances, or any other active intervention. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third reviewer consulted. The author of the primary study was contacted where necessary. The studies were grouped according to treatment type and duration of follow up. Twenty potentially relevant RCTs were identified. Eight trials were excluded leaving 12 RCTs for analysis. Stabilisation splint therapy was compared to: acupuncture, bite plates, biofeedback/stress management, visual feedback, relaxation, jaw exercises, non-occluding appliance and minimal/no treatment. There was no evidence of a statistically significant difference in the effectiveness of stabilisation splint therapy (SS) in reducing symptoms in patients with pain dysfunction syndrome

  6. Splint therapy for trigger finger in children.

    PubMed

    Tsuyuguchi, Y; Tada, K; Kawaii, H

    1983-02-01

    During the last 9 years, 83 trigger digits in 65 children were treated using a modified coil spring splint which maintains the interphalangeal (IP) joint in neutral extension or hyperextension. Sixty-two digits (75%) were completely healed following splint therapy alone, after an average period of splinting for 9.4 months. Eight digits which did not improve with splinting were surgically treated. Splint therapy to maintain the IP joint in neutral extension or hyperextension proved markedly effective in our series.

  7. Effect of an occlusal splint on sleep bruxism in children in a pilot study with a short-term follow up.

    PubMed

    Giannasi, Lilian Chrystiane; Santos, Israel Reis; Alfaya, Thays Almeida; Bussadori, Sandra Kalil; Franco de Oliveira, Luis Vicente

    2013-10-01

    The aim of the present study was to evaluate the effect of the use of an occlusal splint in children with bruxism in a pilot study with a short-term follow up. Seventeen children were recruited, only nine of whom formed the sample following the application of the inclusion criteria: presence of sleep bruxism for at least six months (based on parents' reports); presence of at least the first permanent molars; and no previous history of treatment involving an occlusal splint. The sample was submitted to a clinical exam. Other sleep problems were screened with the use of a sleep questionnaire filled out by parents before and after 90 days of occlusal splint usage. The children received a flat acrylic resin splint with full coverage of the occlusal surfaces to be worn in the maxilla. In children with erupting teeth, a space was created in the splint to allow normal eruption. After the 90-day period, the absence of sleep bruxism and sleep movements was noted in most of children. Moreover, snoring was reduced in nearly 50%, which raises a new issue to be investigated with regard to the pathophysiology of sleep bruxism. The use of an occlusal splint was effective in reducing the symptoms of sleep bruxism and other sleep problems. Further investigations should be carried out on the relationship between snoring and sleep bruxism in children. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Clinical and radiological outcomes after treatment of sagittal fracture of mandibular condyle (SFMC) by using occlusal splint in children.

    PubMed

    Liu, Chang-Kui; Meng, Fan-Wen; Tan, Xin-Ying; Xu, Juan; Liu, Hua-Wei; Liu, San-Xia; Huang, Hai-Tao; Yan, Rong-Zeng; Hu, Min; Hu, Kai-Jin

    2014-02-01

    This study was designed to investigate the effects of occlusal splints in the treatment of sagittal fractures of the mandibular condyle in children. From January 1995 to December 2011, 37 sagittal fractures of the mandibular condyle in 30 patients aged 4-8 years old were included in this study. All the patients were treated with 1-2mm occlusal splints in the molar region. The mouths of the patients were kept slightly open by the occlusal splints for 3-6 months, and we reviewed the clinical and radiological remodelling of the affected condyles after treatment. Excellent (n=20) and good (n=10) clinical outcomes were achieved with full radiological remodelling seen in 19 and partial remodelling in 11. Treatment with occlusal splints is effective in delivering good results and function with minimal morbidity in children with sagittal fractures of the condyle, while permitting ongoing remodelling and growth in the short term. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Effectiveness of Ear Splint Therapy for Ear Deformities

    PubMed Central

    2017-01-01

    Objective To present our experience with ear splint therapy for babies with ear deformities, and thereby demonstrate that this therapy is an effective and safe intervention without significant complications. Methods This was a retrospective study of 54 babies (35 boys and 19 girls; 80 ears; age ≤3 months) with ear deformities who had received ear splint therapy at the Center for Torticollis, Department of Physical Medicine and Rehabilitation, Ajou University Hospital between December 2014 and February 2016. Before the initiation of ear splint therapy, ear deformities were classified with reference to the standard terminology. We compared the severity of ear deformity before and after ear splint therapy by using the physician's ratings. We also compared the physician's ratings and the caregiver's ratings on completion of ear splint therapy. Results Among these 54 babies, 41 children (58 ears, 72.5%) completed the ear splint therapy. The mean age at initiation of therapy was 52.91±18.26 days and the treatment duration was 44.27±32.06 days. Satyr ear, forward-facing ear lobe, Darwinian notch, overfolded ear, and cupped ear were the five most common ear deformities. At the completion of therapy, the final physician's ratings of ear deformities were significantly improved compared to the initial ratings (8.28±1.44 vs. 2.51±0.92; p<0.001). There was no significant difference between the physician's ratings and the caregiver's ratings at the completion of ear splint therapy (8.28±1.44 vs. 8.0±1.61; p=0.297). Conclusion We demonstrated that ear splint therapy significantly improved ear deformities in babies, as measured by quantitative rating scales. Ear splint therapy is an effective and safe intervention for babies with ear deformities. PMID:28289646

  10. A Simplified Way for the Stabilization of Pediatric Mandibular Fracture With an Occlusal Splint.

    PubMed

    Demirkol, Mehmet; Demirkol, Nermin; Abdo, Omar Hasan; Aras, Mutan Hamdi

    2016-06-01

    The management of pediatric mandibular fractures is challenging for maxillofacial surgeons due to ongoing mandibular growth involving tooth buds. The treatment of such fractures has been a topic of much research. Generally accepted methods for the treatment of mandibular parasymphyseal or symphyseal fractures in children are conservative approaches involving the use of acrylic splints, lateral compression with an open-cap splint stabilized by circummandibular wiring, and maxillomandibular fixation with an arch bar and eyelet wiring. The aim of this technical note was to describe a straightforward approach to the treatment of pediatric mandibular fractures, in which an occlusal splint is secured to prevent trauma to the soft tissue, without the need for general anesthesia.

  11. Choice of biomaterials—Do soft occlusal splints influence jaw-muscle activity during sleep? A preliminary report

    NASA Astrophysics Data System (ADS)

    Arima, Taro; Takeuchi, Tamiyo; Tomonaga, Akio; Yachida, Wataru; Ohata, Noboru; Svensson, Peter

    2012-12-01

    AimThe choice of biomaterials for occlusal splints may significantly influence biological outcome. In dentistry, hard acrylic occlusal splints (OS) have been shown to have a temporary and inhibitory effect on jaw-muscle activity, such as tooth clenching and grinding during sleep, i.e., sleep bruxism (SB). Traditionally, this inhibitory effect has been explained by changes in the intraoral condition rather than the specific effects of changes in occlusion. The aim of this preliminary study was to investigate the effect of another type of occlusal surface, such as a soft-material OS in addition to a hard-type OS in terms of changes in jaw-muscle activity during sleep. Materials and methodsSeven healthy subjects (mean ± SD, six men and one woman: 28.9 ± 2.7 year old), participated in this study. A soft-material OS (ethylene vinyl acetate copolymer) was fabricated for each subject and the subjects used the OS for five continuous nights. The EMG activity during sleep was compared to baseline (no OS). Furthermore, the EMG activity during the use of a hard-type OS (Michigan-type OS, acrylic resin), and hard-type OS combined with contingent electrical stimulation (CES) was compared to baseline values. Each session was separated by at least two weeks (washout). Jaw-muscle activity during sleep was recorded with single-channel ambulatory devices (GrindCare, MedoTech, Herlev, Denmark) in all sessions for five nights. ResultsJaw-muscle activity during sleep was 46.6 ± 29.8 EMG events/hour at baseline and significantly decreased during the hard-type OS (17.4 ± 10.5, P = 0.007) and the hard-type OS + CES (10.8 ± 7.1, P = 0.002), but not soft-material OS (36.3 ± 24.5, P = 0.055). Interestingly, the soft-material OS (coefficient of variance = 98.6 ± 35.3%) was associated with greater night-to-night variations than baseline (39.0 ± 11.8%) and the hard-type OS + CES (53.3 ± 13.7%, P < 0.013). ConclusionThe present pilot study in small sample showed that a soft

  12. Evaluation of the effectiveness of a semi-finished occlusal appliance – a randomized, controlled clinical trial

    PubMed Central

    2013-01-01

    Introduction Painful temporomandibular disorders (TMDs) are usually treated with physiotherapy, self-exercises, medication-based therapy and splint therapy. For splint therapy different types of splints are available. Therefore this randomized controlled study compared the effectiveness of a semi-finished occlusal appliance (SB) with a laboratory-made occlusal appliance (SS) in myofascial pain patients. Method The trial subjects allocated to the experimental groups with the (SB) occlusal appliance and those provided with a laboratory-made occlusal appliance (SS) did, in addition, receive conservative treatment (self-exercises, drug-based and manual therapy). The control group was given conservative therapy (CO) only. Overall, a total of 63 patients participated in the study with each group consisting of 21 subjects. Results When the first follow-up examination took place (14 days after splint insertion) mouth opening within the SB group was significantly enlarged. When the second examination was conducted (2.5 months after splint insertion) mouth opening was significantly enlarged in both splint groups when compared with the initial value. In the control group, no significant enlargement of mouth opening was detected. At no point there was a significant reduction in the number of pressure-sensitive areas of the TMJ. On palpation of the masticatory muscles however, a significant reduction in the number of pressure-sensitive areas could be observed within the CO group and the SS group after 2.5 months. When comparing pain reduction (muscle/joint pain) and mouth opening, no significant differences could be detected between the treatments. Conclusion The results suggest that TMD should be treated conservatively. In cases of restricted mouth opening, the additional use of occlusal appliances can eliminate the patient’s discomfort more quickly. In this context, the tested, semi-finished occlusal appliance appears to offer an immediately available, temporary alternative

  13. Body position effects on sternocleidomastoid and masseter EMG pattern activity in patients undergoing occlusal splint therapy.

    PubMed

    Ormeño, G; Miralles, R; Santander, H; Casassus, R; Ferrer, P; Palazzi, C; Moya, H

    1997-10-01

    This study was conducted in order to determine the effects of body position on electromyographic (EMG) activity of sternocleidomastoid and masseter muscles, in 15 patients with myogenic cranio-cervical-mandibular dysfunction undergoing occlusal splint therapy. EMG activity was recorded by placing surface electrodes on the sternocleidomastoid and masseter muscles (contralateral to the habitual sleeping side of each patient). EMG activity at rest and during swallowing of saliva and maximal voluntary clenching was recorded in the following body positions: standing, supine and lateral decubitus. In the sternocleidomastoid muscle significant higher EMG activities at rest and during swallowing were recorded in the lateral decubitus position, whereas during maximal voluntary clenching EMG activity did not change. In the masseter muscle significant higher EMG activity during maximal voluntary clenching in a standing position was observed, whereas EMG activity at rest and during swallowing did not change. The opposite pattern of EMG activity supports the idea that there may exist a differential modulation of the motor neuron pools of the sternocleidomastoid and masseter muscles, of peripheral and/or central origin. This suggests that the presence of parafunctional habits and body position could be closely correlated with the clinical symptomatology in these muscles in patients with myogenic craniomandibular dysfunction.

  14. [SCREW-BASED INTERMAXILLARY TRACTION COMBINED WITH OCCLUSAL SPLINT FOR TREATMENT OF PEDIATRIC MANDIBULAR CONDYLAR FRACTURE].

    PubMed

    Wu, Yang; Long, Xing; Deng, Mohong; Cai, Hengxing; Meng, Qinggong; Li, Bo

    2015-04-01

    To evaluate the effectiveness of the screw-based intermaxillary traction combined with occlusal splint in the treatment of pediatric mandibular condylar fracture. Between June 2005 and December 2013, 35 pediatric patients with 49 mandibular condylar fractures were treated, and the clinical data were retrospectively reviewed. There were 25 boys and 10 girls, aged 3-13 years (mean, 7.3 years). The injury causes included falling (18 cases), traffic accident (14 cases), and violence (3 cases). The time between injury and treatment was 2-30 days (mean, 6.8 days). Restricted mouth opening was observed, and the maximal mouth opening was (22.74 +/- 7.22) mm except 3 patients who were too young to measure. Condylar fractures were located at the left (12 cases), at the right (9 cases), at bilateral (14 cases) based on the sites; and fractures were classified as intracapsular (35 fractures), neck (10 fractures), and subcondylar (4 fractures) based on the fracture line. Four self-drilling titanium screws were inserted into the alveolar bone of both maxilla and mandible. After screw inserting, an occlusal splint with a fulcrum was used on the affected side and elastic band was put to perform anterior intermaxillary traction. After 1 month, the screws and splint were removed. Follow-up examinations were carried out on schedule. All the patients were followed up from 6 months to 8 years and 10 months (median, 71 months). No screw-related complication occurred in the others except one case of screw loosening. The postoperative maximal mouth opening was (38.82 +/- 2.02) nim. Mild joint noise was found in 4 cases and opening deviation occurred in 6 cases. Radiographic results demonstrated complete condyle remodeling was achieved in 24 cases (32 fractures), and moderate remodeling in 11 cases (17 fractures) at last follow-up. The screw-based intermaxillary traction combined with occlusal splint might be an effective method for pediatric mandibular condylar fracture. The screw

  15. Digital Michigan splint - from intraoral scanning to plasterless manufacturing.

    PubMed

    Dedem, Philipp; Türp, Jens C

    2016-01-01

    To investigate whether the fully digital, plasterless fabrication of clinically usable Michigan splints can be accomplished in a time- and cost-efficient manner. Digital scans of the maxillary and mandibular arches of 10 subjects were acquired with an intraoral scanner (3Shape, Copenhagen) and used to generate virtual models of the dental arches. Jaw relation records were made using jigs placed on the subjects' anterior teeth, and silicone registration material was referenced to the jaw models. The data sets were then sent via the company's online portal to the dental laboratory, where computer-aided design (CAD) of the Michigan-type maxillary splints was performed. After receiving the designs, the splints were milled in-office using computer-aided manufacturing (CAM) software, and finished manually. During try-in, the splints where checked for fit, retention quality, and occlusal contacts of the mandibular teeth on the splint surfaces in static and dynamic occlusion. Fit and retention were clinically acceptable in 10 splints and 9 splints, respectively. The number of initial occlusal contacts on the splint surfaces ranged from 4 to 16. The question addressed in this study can be answered in the affirmative. Some of the main advantages of digital manufacturing of Michigan splints over traditional, conventional, impression-based manufacturing are the time-efficient manufacturing process, the high material quality, and the possibility of manufacturing duplicate splints.

  16. Oral splint for temporomandibular joint disorders with revolutionary fluid system

    PubMed Central

    Srivastava, Rahul; Jyoti, Bhuvan; Devi, Parvathi

    2013-01-01

    Temporomandibular joint (TMJ) diseases and disorders refer to a complex and poorly understood set of conditions, manifested by pain in the area of the jaw and associated muscles and limitations in the ability to make the normal movements of speech, facial expression, eating, chewing, and swallowing. The conventional soft occlusal splint therapy is a much safer and effective mode of a conservative line of therapy in comparison to the surgical therapy for temporomandibular joint disorders (TMD). The purpose of this article is to review the Aqualizer™, an hydrostatic oral splint, as accurate, effective treatment and differential diagnostic tool in TMD that allow treating the patient's pain quickly and accurately saving valuable treatment time. The review article has been prepared doing a literature review from the world-wide web and pubmed/medline. PMID:24019797

  17. Efficacy of splint therapy for the management of temporomandibular disorders: a meta-analysis.

    PubMed

    Zhang, Chao; Wu, Jun-Yi; Deng, Dong-Lai; He, Bing-Yang; Tao, Yuan; Niu, Yu-Ming; Deng, Mo-Hong

    2016-12-20

    Temporomandibular disorders (TMD) are a group of clinical problems affecting temporomandibular joint (TMJ), myofascial muscles and other related structures. Splint therapy is the most commonly used approach to treatment of TMD, but its effectiveness is remains unclear. We therefore conducted a meta-analysis to evaluate the effectiveness of splint therapy for TMD in adults. The electronic databases PubMed, EMBASE, Cochrane Library, and ClinicalTrials.gov were searched for reports published up to March 31, 2016. Thirteen eligible studies involving 538 patients were identified. The results indicated that splint therapy increased maximal mouth opening (MMO) for patients with a MMO <45mm and reduced pain intensity measured using the visual analogue scale (VAS) for patients with TMD without specific description (TMDSD). Splint therapy also reduced the frequency of painful episodes for patients with TMJ clicking. No publication bias was observed, as determined with Egger's test for all outcomes. On the basis of this evidence, we recommend the use of splints for the treatment and control of TMD in adults.

  18. A paradigm shift in orthognathic surgery? A comparison of navigation, computer-aided designed/computer-aided manufactured splints, and "classic" intermaxillary splints to surgical transfer of virtual orthognathic planning.

    PubMed

    Zinser, Max J; Sailer, Hermann F; Ritter, Lutz; Braumann, Bert; Maegele, Marc; Zöller, Joachim E

    2013-12-01

    Advances in computers and imaging have permitted the adoption of 3-dimensional (3D) virtual planning protocols in orthognathic surgery, which may allow a paradigm shift when the virtual planning can be transferred properly. The purpose of this investigation was to compare the versatility and precision of innovative computer-aided designed and computer-aided manufactured (CAD/CAM) surgical splints, intraoperative navigation, and "classic" intermaxillary occlusal splints for surgical transfer of virtual orthognathic planning. The protocols consisted of maxillofacial imaging, diagnosis, virtual orthognathic planning, and surgical planning transfer using newly designed CAD/CAM splints (approach A), navigation (approach B), and intermaxillary occlusal splints (approach C). In this prospective observational study, all patients underwent bimaxillary osteotomy. Eight patients were treated using approach A, 10 using approach B, and 12 using approach C. These techniques were evaluated by applying 13 hard and 7 soft tissue parameters to compare the virtual orthognathic planning (T0) with the postoperative result (T1) using 3D cephalometry and image fusion (ΔT1 vs T0). The highest precision (ΔT1 vs T0) for the maxillary planning transfer was observed with CAD/CAM splints (<0.23 mm; P > .05) followed by surgical "waferless" navigation (<0.61 mm, P < .05) and classic intermaxillary occlusal splints (<1.1 mm; P < .05). Only the innovative CAD/CAM splints kept the condyles in their central position in the temporomandibular joint. However, no technique enables a precise prediction of the mandible and soft tissue. CAD/CAM splints and surgical navigation provide a reliable, innovative, and precise approach for the transfer of virtual orthognathic planning. These computer-assisted techniques may offer an alternate approach to the use of classic intermaxillary occlusal splints. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All

  19. Efficacy of Selective Grinding Guided by an Occlusal Splint in Management of Myofascial Pain: A Prospective Clinical Trial

    PubMed Central

    Fernández-González, Felipe J.; Cabero-López, Jorge; Brizuela, Aritza; Suazo, Ivan; Pérez-Pevida, Esteban; Cobo, Teresa; Montalban, Oier; Diéguez-Pereira, Markel; Chávarri-Prado, David; de la Pinta, Iker Bellanco; Jiménez-Garrudo, Antonio

    2017-01-01

    Background: For patients whose centric relation (CR) has not been considered at the start and during treatment, the task of achieving an occlusal scheme that works together with the temporomandibular joint, the muscles, and the structures of the stomatognathic apparatus becomes a major concern. Objective: This study aims to describe a reproducible, predictable and to date unreported procedure of selective grinding guided by an occlusal splint and to analyze condylar position (CP) based on the skeletal pattern. Methods: A total of 72 symptomatic patients (38 females and 34 males) were classified into three groups: hyperdivergent, intermediate and hypodivergent. CP was quantified by mounted casts on a measures condyle displacement (MCD) device. Helkimo index was also performed in order to assess the severity of the temporomandibular joint (TMJ) disorders attending to clinical dysfunction, occlusal state and anamnestic dysfunction. Once the stability had been obtained, the splint was progressively reduced until the maximum intercuspation (MIC) was achieved. Results: The vertical displacement was found to be significantly different between the hyperdivergent and other two groups (p<0.01). Comparisons of MCD analysis before and after the selective grinding procedure identified a statistically significant difference in the horizontal and vertical CP (p<0.01) between the different groups whereas the Helkimo Index showed a clear improvement of TMJ disorders. Conclusion: All facial types, specially the hyperdivergent face type, showed a reduction in condylar displacement (CD) and less craniomandibular symptoms using this procedure, making it an excellent technique for clinicians. PMID:28839479

  20. The effect of intermittent use of occlusal splint devices on sleep bruxism: a 4-week observation with a portable electromyographic recording device.

    PubMed

    Matsumoto, H; Tsukiyama, Y; Kuwatsuru, R; Koyano, K

    2015-04-01

    This randomised controlled study investigated the effect of intermittent use of occlusal splints on sleep bruxism compared with that of continuous use by measuring masseter muscle electromyographic activity using a portable electromyographic recording system. Twenty bruxers were randomly allocated to the continuous group and intermittent group. Subjects in the continuous group wore stabilisation splints during sleep for 29 nights continuously, whereas those in the intermittent group wore splints during sleep every other week, that is they used splints on the 1st-7th, 15th-21st and 29th nights. Electromyographic activity of the masseter muscle during sleep was recorded for the following six time points: before (baseline), immediately after, and 1, 2, 3 and 4 weeks after the insertion of a stabilisation splint. The number of nocturnal masseter electromyographic events, duration and the total activity of sleep bruxism were analysed. In the continuous group, nocturnal masseter electromyographic events were significantly reduced immediately and 1 week after the insertion of the stabilisation splint, and duration was reduced immediately after the insertion (P < 0·05, Dunnett's test), but no reduction was observed at 2, 3 and 4 weeks after insertion. In the intermittent group, nocturnal masseter electromyographic events and duration were significantly reduced immediately after and also 4 weeks after insertion of the stabilisation splint (P < 0·05, Dunnett's test). The obtained results of the present exploratory trial indicate that the intermittent use of stabilisation splints may reduce sleep bruxism activity for a longer period compared with that of continuous use. © 2014 John Wiley & Sons Ltd.

  1. A concept to transfer a therapeutic splint position into permanent occlusion with a customized lingual appliance.

    PubMed

    Sachse, Tina; Schwestka-Polly, Rainer; Flieger, Stefanie; Wiechmann, Dirk

    2012-05-21

    The role of occlusion concerning temporomandibular disorder is still unclear but seems to be the only component of the stomathognathic system dentists are able to change morphologically. The aim of the paper is to describe the orthodontist's approach for transferring and maintaining a therapeutic splint position into permanent occlusion using a fully customized lingual appliance. Fixed acrylic bite planes on lower molars were used to maintain a symptom-free condyle position prior to orthodontic treatment. Silicone impressions of the arches including the fixed bite planes were used for the Incognito laboratory procedure. Two digital setups were made. One setup represents the target occlusion. A second setup including the bite planes was used to fabricate an additional set of lower molar brackets. In the leveling stage all teeth except the lower molars were settled to maintain the therapeutic condyle position. Finally, the fixed bite planes were stepwise removed and molar brackets were replaced to establish the permanent occlusion planned with the first setup. The advantage of an individual lingual appliance consists in the high level of congruence between the fabricated setups and the final clinical result. Both the individual scope for design and the precision of the appliance were vitally important in the treatment of a patient with a functional disorder of the masticatory system.

  2. Strength improvements through occlusal splints? The effects of different lower jaw positions on maximal isometric force production and performance in different jumping types

    PubMed Central

    Maurer, Christian; Heller, Sebastian; Sure, Jil-Julia; Fuchs, Daniel; Mickel, Christoph; Wanke, Eileen M.; Groneberg, David A.

    2018-01-01

    Objective The influence of the jaw position on postural control, body posture, walking and running pattern has been reported in the literature. All these movements have in common that a relatively small, but well controlled muscle activation is required. The induced effects on motor output through changed jaw positions have been small. Therefore, it has been questioned if it could still be observed in maximal muscle activation. Method Twenty-three healthy, mid age recreational runners (mean age = 34.0 ± 10.3 years) participated in this study. Three different jump tests (squat jump, counter movement jump, and drop jumps from four different heights) and three maximal strength tests (trunk flexion and extension, leg press of the right and left leg) were conducted. Four different dental occlusion conditions and an additional familiarization condition were tested. Subjects performed the tests on different days for which the four occlusion conditions were randomly changed. Results No familiarization effect was found. Occlusion conditions with a relaxation position and with a myocentric condylar position showed significantly higher values for several tests compared to the neutral condition and the maximal occlusion position. Significance was found in the squat jump, countermovement jump, the drop jump from 32cm and 40cm, trunk extension, leg press force and rate of force development. The effect due to the splint conditions is an improvement between 3% and 12% (min and max). No influence of the jaw position on symmetry or balance between extension and flexion muscle was found. Conclusion An influence of occlusion splints on rate of force development (RFD) and maximal strength tests could be confirmed. A small, but consistent increase in the performance parameters could be measured. The influence of the occlusion condition is most likely small compared to other influences as for example training status, age, gender and circadian rhythm. PMID:29474465

  3. Ex vivo tracheomalacia model with 3D-printed external tracheal splint.

    PubMed

    Kaye, Rachel; Goldstein, Todd; Aronowitz, Danielle; Grande, Daniel A; Zeltsman, David; Smith, Lee P

    2017-04-01

    To design and evaluate an ex vivo model of tracheomalacia with and without a three-dimensional (3D)-printed external tracheal splint. Prospective, ex vivo animal trial. Three groups of ex vivo porcine tracheas were used: 1) control (unmanipulated trachea), 2) tracheomalacia (tracheal rings partially incised and crushed), and 3) splinted tracheomalacia (external custom tracheal splint fitted onto group 2 trachea). Each end of an ex vivo trachea was sealed with a custom-designed and 3D-printed cap; a transducer was placed through one end to measure the pressure inside the trachea. Although the negative pressure was applied to the tracheal lumen, the tracheal wall collapse was measured externally and internally using a bronchoscope. Each group had at least three recorded trials. Tracheal diameter was evaluated using ImageJ software (National Institutes of Health, Bethesda, MD) and was averaged between two raters. Average tracheal occlusion percentage was compared using Student t test. The average occlusion was 31% for group 1, 87.4% for group 2, and 20% for group 3. Significant differences were found between the control and tracheomalacia groups (P < 0.01) and the tracheomalacia and splinted tracheomalacia groups (P < 0.01). There was no significant difference between the control and splinted tracheomalacia groups (P = 0.13). Applied pressure was plotted against occlusion and regression line slope differed between the tracheomalacia (0.91) and control (0.12) or splinted tracheomalacia (0.39) groups. We demonstrate the potential for an ex vivo tracheomalacia model to reproduce airway collapse and show that this collapse can be treated successfully with a 3D-printed external splint. These results are promising and justify further studies. N/A. Laryngoscope, 127:950-955, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Recurrence of amblyopia after occlusion therapy.

    PubMed

    Bhola, Rahul; Keech, Ronald V; Kutschke, Pamela; Pfeifer, Wanda; Scott, William E

    2006-11-01

    To determine the stability of visual acuity (VA) after a standardized occlusion regimen in children with strabismic and/or anisometropic amblyopia. Retrospective, population-based, consecutive observational case series. Four hundred forty-nine patients younger than 10 years who underwent an occlusion trial for amblyopia and were observed until there was a recurrence of amblyopia or for a maximum of 1 year after decrease or cessation of occlusion therapy. We performed a retrospective chart review of all patients treated by occlusion therapy for strabismic and/or anisometropic amblyopia at our institution over a 34-year period. Of the 1621 patients identified in our database, 449 met the eligibility criteria and were included in this study. Patients having at least a 2 logarithm of the minimum angle of resolution (logMAR)-level improvement in VA by optotypes or a change from unmaintained to maintained fixation preference during the course of occlusion therapy were included. A recurrence of amblyopia was defined as > or =2 logMAR levels of VA reduction or reversal of fixation preference within 1 year after a decrease or cessation of occlusion therapy. Recurrence of amblyopia after a decrease or cessation of occlusion therapy and its relationship with patient age and VA of the amblyopic eye at the time of decrease or cessation of occlusion therapy. Of 653 occlusion trials, 179 (27%) resulted in recurrence of amblyopia. The recurrence was found to be inversely correlated with patient age. There was no statistically significant association between the recurrence of amblyopia and VA of the amblyopic eye at the end of maximal occlusion therapy. There is a clinically important risk of amblyopia recurrence when occlusion therapy is decreased before the age of 10 years. The risk of recurrence is inversely correlated with age (P<0.0001).

  5. The fabrication of a customized occlusal splint based on the merging of dynamic jaw tracking records, cone beam computed tomography, and CAD-CAM digital impression.

    PubMed

    Aslanidou, Katerina; Kau, Chung How; Vlachos, Christos; Saleh, Tayem Abou

    2017-01-01

    The aim of this case report was to present the procedure of fabricating a customized occlusal splint, through a revolutionary software that combines cone beam computed tomography (CBCT) with jaw motion tracking (JMT) data and superimposes a digital impression. The case report was conducted on a 46-year-old female patient diagnosed with the temporomandibular disorder. A CBCT scan and an optical impression were obtained. The range of the patient's mandibular movements was captured with a JMT device. The data were combined in the SICAT software (SICAT, Sirona, Bonn, Germany). The software enabled the visualization of patient-specific mandibular movements and provided a real dynamic anatomical evaluation of the condylar position in the glenoid fossa. After the assessment of the range of movements during opening, protrusion, and lateral movements all the data were sent to SICAT and a customized occlusal splint was manufactured. The SICAT software provides a three-dimensional real-dynamic simulation of mandibular movements relative to the patient-specific anatomy of the jaw; thus, it opens new possibilities and potentials for the management of temporomandibular disorders.

  6. Ear Acupuncture Therapy for Masticatory Myofascial and Temporomandibular Pain: A Controlled Clinical Trial.

    PubMed

    Ferreira, Luciano Ambrosio; Grossmann, Eduardo; Januzzi, Eduardo; Gonçalves, Rafael Tardin Rosa Ferraz; Mares, Fernando Antonio Guedes; de Paula, Marcos Vinicius Queiroz; Carvalho, Antonio Carlos Pires

    2015-01-01

    Ear acupuncture works by reducing painful sensations with analgesic effect through microsystem therapy and has been demonstrated to be as effective as conventional therapies in the control of facial pain. This clinical trial aimed to evaluate the adjuvant action of auricular acupuncture through an observation of the evolution of temporomandibular and masticatory myofascial symptoms in two groups defined by the therapies elected: auricular acupuncture associated with occlusal splint (study) and the use of the occlusal splint plate alone (control). We have selected 20 patients, who were randomly allocated into two groups of ten individuals. Symptoms were evaluated in five different moments, every seven days. We analyzed the orofacial muscle and joint palpation in order to measure the intensity of the experienced pain. Both groups showed a statistically significant decrease in muscle and joint symptoms (p < 0.05). However, comparisons between the groups showed an expressive and significant reduction of symptomatology in the study group (p < 0.05) already on the first week of therapy. According to the results, to the methodological criteria developed and statistical analysis applied, the conclusion is that auricular acupuncture therapy has synergistic action on conventional occlusal splint treatment. It was demonstrated to be effective in the reduction of symptoms in the short term.

  7. Ear Acupuncture Therapy for Masticatory Myofascial and Temporomandibular Pain: A Controlled Clinical Trial

    PubMed Central

    Ferreira, Luciano Ambrosio; Grossmann, Eduardo; Januzzi, Eduardo; Gonçalves, Rafael Tardin Rosa Ferraz; Mares, Fernando Antonio Guedes; de Paula, Marcos Vinicius Queiroz; Carvalho, Antonio Carlos Pires

    2015-01-01

    Ear acupuncture works by reducing painful sensations with analgesic effect through microsystem therapy and has been demonstrated to be as effective as conventional therapies in the control of facial pain. This clinical trial aimed to evaluate the adjuvant action of auricular acupuncture through an observation of the evolution of temporomandibular and masticatory myofascial symptoms in two groups defined by the therapies elected: auricular acupuncture associated with occlusal splint (study) and the use of the occlusal splint plate alone (control). We have selected 20 patients, who were randomly allocated into two groups of ten individuals. Symptoms were evaluated in five different moments, every seven days. We analyzed the orofacial muscle and joint palpation in order to measure the intensity of the experienced pain. Both groups showed a statistically significant decrease in muscle and joint symptoms (p < 0.05). However, comparisons between the groups showed an expressive and significant reduction of symptomatology in the study group (p < 0.05) already on the first week of therapy. According to the results, to the methodological criteria developed and statistical analysis applied, the conclusion is that auricular acupuncture therapy has synergistic action on conventional occlusal splint treatment. It was demonstrated to be effective in the reduction of symptoms in the short term. PMID:26351510

  8. Effect of occlusal splints on the temporomandibular disorders, dental wear and anxiety of bruxist children.

    PubMed

    Restrepo, Claudia C; Medina, Isabel; Patiño, Isabel

    2011-08-01

    To evaluate the effectiveness of occlusal splints to reduce the signs and symptoms of temporomandibular disorders (TMD), dental wear and anxiety in a group of bruxist children. All of the subjects were 3 to 6 years old, had complete primary dentition, class I occlusion and were classified as bruxist according to the minimal criteria of the ICSD for bruxism. For each child, anxiety was evaluated with the Conners' Parent Rating Scales (CPRS). The TMD were evaluated using the RDC/TMD. The dental wear was processed in digital format with Mat Lab® and Lab view® software to determine its size and form. The children were randomized into an experimental (n=19) and a control (n=17) group. The children in the experimental group used rigid bite plates for a two-year period, until mixed dentition. Afterwards, the CPRS and the RDC/TMD were applied again and dental casts were taken. Comparisons of the variables regarding dental wear, signs and symptoms of TMD and anxiety before and after treatment among the groups were analyzed using the t-test, the Wilcoxon rank sum test and the Mann-Whitney test. The subjects in the experimental group showed no statistically significant difference regarding anxiety levels and dental wear when compared with the control group. The signs and symptoms of TMD were not reduced except for the deviation in mouth opening. The use of rigid occlusal bite plates was not efficient in reducing the signs of bruxism as a whole but did reduce the deviation in mouth opening.

  9. Three-Dimensional Planning in Maxillofacial Fracture Surgery: Computer-Aided Design/Computer-Aided Manufacture Surgical Splints by Integrating Cone Beam Computerized Tomography Images Into Multislice Computerized Tomography Images.

    PubMed

    Ren, Jiayin; Zhou, Zhongwei; Li, Peng; Tang, Wei; Guo, Jixiang; Wang, Hu; Tian, Weidong

    2016-09-01

    This study aimed to evaluate an innovative workflow for maxillofacial fracture surgery planning and surgical splint designing. The maxillofacial multislice computerized tomography (MSCT) data and dental cone beam computerized tomography (CBCT) data both were obtained from 40 normal adults and 58 adults who suffered fractures. The each part of the CBCT dentition image was registered into MSCT image by the use of the iterative closest point algorithm. Volume evaluation of the virtual splints that were designed by the registered MSCT images and MSCT images of the same object was performed. Eighteen patients (group 1) were operated without any splint. Twenty-one (group 2) and 19 patients (group 3) used the splints designed according to the MSCT images and registered MSCT images, respectively. The authors' results showed that the mean errors between the 2 models ranged from 0.53 to 0.92 mm and the RMS errors ranged from 0.38 to 0.69 mm in fracture patients. The mean errors between the 2 models ranged from 0.47 to 0.85 mm and the RMS errors ranged from 0.33 to 0.71 mm in normal adults. 72.22% patients in group 1 recovered occlusion. 85.71% patients in group 2, and 94.73% patients in group 3 reconstructed occlusion. There was a statistically significant difference between the MSCT images based splints' volume and the registered MSCT splints' volume in patients (P <0.05). The MSCT images based splints' volume was statistically significantly distinct from the registered MSCT splints' volume in normal adults (P <0.05). There was a statistically significant difference between the MSCT images based splints' volume and the registered MSCT splints' volume in patients and normal adults (P <0.05). The occlusion recovery rate of group 3 was better than that of group 1 and group 2. The way of integrating CBCT images into MSCT images for splints designing was feasible. The volume of the splints designed by MSCT images tended to be smaller than the splints designed by

  10. Shin splints--a literature review.

    PubMed

    Bates, P

    1985-09-01

    "Shin splints" is not a specific diagnosis. It is merely a descriptive term that describes chronic exertional shin pain in an athlete. The evidence seems clear that shin splint pain has many different causes and this reflects the variation in the anatomy. It would be preferable to describe shin splint pain by location and aetiology, for example, lower medial tibial pain due to periostitis or upper lateral tibial pain due to elevated compartment pressure. This would aid communication between physicians and also direct therapy more accurately.

  11. Shin splints--a literature review.

    PubMed Central

    Bates, P

    1985-01-01

    "Shin splints" is not a specific diagnosis. It is merely a descriptive term that describes chronic exertional shin pain in an athlete. The evidence seems clear that shin splint pain has many different causes and this reflects the variation in the anatomy. It would be preferable to describe shin splint pain by location and aetiology, for example, lower medial tibial pain due to periostitis or upper lateral tibial pain due to elevated compartment pressure. This would aid communication between physicians and also direct therapy more accurately. Images p132-a PMID:3907743

  12. An electromyographic study to assess the minimal time duration for using the splint to raise the vertical dimension in patients with generalized attrition of teeth.

    PubMed

    Nanda, Aditi; Jain, Veena; Srivastava, Achal

    2011-01-01

    To investigate the effect of restoration of lost vertical by centric stabilizing splint on electromyographic (EMG) activity of masseter and anterior temporalis muscles bilaterally in patients with generalized attrition of teeth. EMG activity of anterior temporalis and masseter muscle was recorded bilaterally for 10 patients whose vertical was restored with centric stabilizing splint. The recording was done at postural rest position and in maximum voluntary clenching for each subject before the start of treatment, immediately after placement of splint and at subsequent recall visits, with splint and without the splint. The EMG activity at postural rest position (PRP) and maximum voluntary clench (MVC) decreased till 1 month for both the muscles. In the third month, an increase in muscle activity toward normalization was noted at PRP, both with and without splint. At MVC in the third month, the muscle activity without splint decreased significantly as compared to pretreatment values for anterior temporalis and masseter, while with the splint an increase was seen beyond the pretreatment values. A definite response of anterior temporalis and masseter muscle was observed over a period of 3 months. This is suggestive that the reversible increase in vertical prior to irreversible intervention must be carried out for a minimum of 3 months to achieve neuromuscular deprogramming. This allows the muscle to get adapted to the new postural position and attain stability in occlusion following splint therapy.

  13. Occlusion, sternocleidomastoid muscle activity, and body sway: a pilot study in male astronauts.

    PubMed

    Sforza, Chiarella; Tartaglia, Gianluca M; Solimene, Umberto; Morgun, Valery; Kaspranskiy, Rustem R; Ferrario, Virgilio F

    2006-01-01

    The modifications induced by microgravity on the coordinated patterns of movement of the head, trunk, and limbs are reported on extensively. However, apparently there is little data on the masticatory muscles. In normal gravitational conditions, information from the neck and stomatognathic apparatus play a role in maintaining the body's balance and equilibrium. The current pilot study used normal gravity conditions to investigate the hypothesis of a functional coupling between occlusion and neck muscles and body postural oscillations. The immediate effect of modified occlusal surfaces on the contraction pattern of the sternocleidomastoid muscles during maximum voluntary clenching and on the oscillation of the center of foot pressure was analyzed in 11 male astronauts (aged 31-54 yrs). All subjects were healthy and free from pathologies of the neck and stomatognathic apparatus. Occlusal splints were prepared using impressions of their dental arches. The splints were modeled on the mandibular arch, had only posterior contacts, and were modified to obtain a more symmetric, standardized contraction of the masseter and temporalis muscles during teeth clenching. Surface EMG activity of the sternocleidomastoid muscles was recorded during a maximal voluntary clench with and without the splint. Sternocleidomastoid potentials were standardized as percent of the mean potentials recorded during a maximum contralateral rotation of the head, and the symmetry of the EMG waves of left- and right-side muscles was measured. Body sway was assessed with and without the splint, either with eyes open or closed. The variations of the center of foot pressure were analyzed through bivariate analysis, and the area of the 90% standard ellipse was computed. Within each visual condition (eyes open or closed), the difference between the areas of oscillation measured with and without the splint was computed. Muscular activity was more symmetric with the splint. The area of oscillation of the

  14. The Conservative Treatment of Pediatric Mandible Fracture With External Nasal Splint.

    PubMed

    Sharifi, Reza; Hasheminasab, Mahboube

    2016-09-01

    The frequency of mandible fractures is relatively less in children compared with adults, but their treatment is significantly more challenging due to the concerns regarding mandible growth and the developing dentition. The authors have introduced a new way of closed reduction by using external nasal splints. In 3 patients aged between 4 and 6-year old with parasymphyseal and body fractures of mandible, fractures were reduced under general anesthesia and thermoplastic nasal splints were directly formed and trimmed to fit the lingual surface of mandible.Splints were fixed to mandible with circummandibular wiring and were retained in place for 3 weeks. All fractures healed uneventfully and the occlusion in all patients was satisfactory. All patients gained good masticatory efficiency. There was no need to use the intermaxillary fixation in any of the patients. Using thermoplastic external nasal splint for fracture stabilization in children is an easy, rapid, nonexpensive, and conservative way to treat mandible fractures in pediatric patients.

  15. Therapies most frequently used for the management of bruxism by a sample of German dentists.

    PubMed

    Ommerborn, Michelle A; Taghavi, Jalleh; Singh, Preeti; Handschel, Joerg; Depprich, Rita A; Raab, Wolfgang H M

    2011-03-01

    At present, there is little information available on how practicing dentists manage bruxism patients with respect to conservative, reversible techniques as compared to irreversible techniques. The purpose of this study was to determine the most commonly applied therapies used for the management of bruxism by German general dentists (GDs) and dental specialists. In addition, efforts were made to gather information on the knowledge and opinion of GDs and specialists regarding the role of occlusal interferences, in particular, on the development of sleep bruxism. A 13-item questionnaire was developed and mailed to all active members of the statutory dental insurance providers of the German North Rhine (n=5500; 2006 roster) and the German Westphalia-Lippe area (n=4984; 2006 roster). Group differences were statistically analyzed using chi-square tests for the qualitative variables and Mann-Whitney U tests for the quantitative variables (α=.05). Occlusal splints were by far the most frequently prescribed therapy for the management of bruxism, followed by relaxation techniques, occlusal equilibration, physiotherapy, and prosthodontic reconstruction. The occlusal stabilization splint with canine protected articulation was the splint type most often prescribed, whereas respondents used unadjusted soft splints for approximately 8% of their bruxism patients. Comparison of the opinions of all responding practicing dentists with that of experts in regard to the statement that "sleep bruxism is caused by occlusal interferences" showed a significant difference between the 2 groups (P=.021). Eighty-five percent of the experts disagreed with this statement, and only 47.7% of the practicing dentists had the same opinion as the experts. Most practicing dentists seem to concur with current scientific recommendations, and express the opinion that the management of bruxism should predominantly be conservative and reversible; however, the findings of the present survey reveal diverse

  16. A Myoelectric Hand Splint

    ERIC Educational Resources Information Center

    Silverstein, Frances; And Others

    1974-01-01

    Development of a myoelectrically controlled hand splint permitting ambulating mobility of the user is discussed. The role of occupational therapy in the research and design of the device and the training of the patient are emphasized. (Authors)

  17. The vacuum splint: an aid in emergency splinting of fractures

    PubMed Central

    Letts, R. M.; Hobson, D. A.

    1973-01-01

    The vacuum splint has been shown to be a simple, safe and effective method of emergency splinting of fractured extremities. The splint is simply constructed from clear vinyl sheeting and contains 2-mm. expanded polystyrene balls. Evacuation of air causes the splint to become rigid, thereby providing stability and immobilization of the limb. The splint is radiolucent, containing no obstructive metal components that would interfere with the radiographic appearance of the injured limb. The ease of application of this splint makes it especially effective for the emergency splinting of fractures in children. ImagesFIG. 1FIG. 2AFIG. 2BFIG. 3FIG. 4 PMID:4742489

  18. Part-time occlusion therapy for amblyopia in older children

    PubMed Central

    Singh, Inderpreet; Sachdev, Nishant; Kaushik, Sushmita

    2008-01-01

    Aim: To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Materials and Methods: Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Statistical Analysis: Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. Results: All four groups showed significant visual improvement after 18 weeks of occlusion therapy (P<0.001). Seventy-three (73%) of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups (P=0.083). However, in severe amblyopia (vision 20/100 or worse), six hours (P=0.048) and full-time occlusion (P=0.027) treatment were significantly more effective than two hours occlusion. Conclusion: All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy. PMID:18974515

  19. Part-time occlusion therapy for amblyopia in older children.

    PubMed

    Singh, Inderpreet; Sachdev, Nishant; Brar, Gagandeep S; Kaushik, Sushmita

    2008-01-01

    To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. All four groups showed significant visual improvement after 18 weeks of occlusion therapy ( P < 0.001). Seventy-three (73%) of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups ( P =0.083). However, in severe amblyopia (vision 20/100 or worse), six hours ( P =0.048) and full-time occlusion ( P =0.027) treatment were significantly more effective than two hours occlusion. All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy.

  20. Anterior midline point stop device (AMPS) in the treatment of myogenous TMDs: comparison with the stabilization splint and control group.

    PubMed

    Al Quran, Firas A M; Kamal, Mudar S

    2006-06-01

    Two occlusal splints, the full-arch stabilization splint and the anterior midline point stop (AMPS) device, were evaluated for their efficiency in relieving myogenous temporomandibular disorders (TMD). One hundred and fourteen patients with myogenous TMD were distributed into 3 groups. The first group was treated with the AMPS device, the second with the stabilization splint, and the third group was the control group. Pain intensity was scored using the visual analogue scale before treatment and 1 month and 3 months after treatment. Statistical Package for the Social Sciences (SPSS, Chicago, Ill) and multiple comparisons tests were used to compare results before and after treatment and to compare the groups. The use of AMPS device in the first group resulted in a significant improvement after 1 month and 3 months (P < or = .001) and showed a 56.66% pain reduction. A significant improvement was also noticed in the second group (P = .001) with a 47.71% pain reduction. Although pain reduction percentage appeared more in the first group, this was not statistically significant. There was a highly significant difference between groups treated with both kinds of splints and the control group. It was concluded that both types of occlusal splints are beneficial to patients with myogenous TMD.

  1. Shin Splints

    MedlinePlus

    Shin splints Overview The term "shin splints" refers to pain along the shin bone (tibia) — the large bone in the front of your lower leg. Shin splints are common in runners, dancers and military recruits. ...

  2. Histologic and histomorphometric evaluation of peri-implant bone of immediate or delayed occlusal-loaded non-splinted implants in the posterior mandible--an experimental study in monkeys.

    PubMed

    Stokholm, Rie; Isidor, Flemming; Nyengaard, Jens R

    2014-11-01

    The primary aim of this study was to compare the bone reaction around immediate-loaded non-splinted single implants vs. delayed loaded non-splinted single implants placed in healed ridges in the posterior mandible. Six adult Macaca Fascicularis monkeys were used in this study. The first and second premolars and the first molar were extracted in both sides of the mandible. After 3 months of healing, four implants (Replace Select Tapered; Nobel Biocare, Gothenburg, Sweden) with a moderately rough surface (TiUnite, Nobel Biocare) were placed in the edentulous areas of each monkey, two in each side. The implants had a length of 10 mm and a diameter of 3.5 mm. Four groups of varying time and occlusal loading aspects were created: (i) control group: implant placed non-loaded for 3 months; (ii) immediate loaded: implant placed and loaded immediately for 3 months; (iii) immediate loaded: implant placed and loaded immediately for 6 months; and (iv) delayed loaded: implant placed submerged for 3 months and then loaded for 3 months. At the loaded implants, after a second stage surgery, a composite crown was made directly on an abutment mounted on the implant reinsuring simultaneous occlusal contact on the implant crown and the neighboring teeth. After euthanization of the animals, histologic specimens were quantified in the light microscope. All implants were clinically, radiographically, and histologically osseointegrated at the time of euthanization and with only mild signs of inflammation in the peri-implant mucosa. The histologic marginal bone level was located on average 1.14-1.74 mm apical to the margin of the implants in the various groups. The average bone-to-implant contact (BIC) varied between 55% and 65% and the average bone density (i.e., the proportion of mineralized bone tissue from the implant surface and to a distance of 1 mm lateral to the implant) varied between 30.6% and 34.2%. No statistical significant differences between groups were observed in

  3. Reduction of deviation angle during occlusion therapy: in partially accommodative esotropia with moderate amblyopia.

    PubMed

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa; Kwon, Jung Yoon

    2007-09-01

    To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Mean deviation angle with glasses at the start of occlusion treatment was 19.45+/-5.97 PD and decreased to 12.14+/-12.96 PD at 2 years after occlusion therapy (p<0.01). After occlusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia.

  4. Reduction of Deviation Angle During Occlusion Therapy: In Partially Accommodative Esotropia with Moderate Amblyopia

    PubMed Central

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa

    2007-01-01

    Purpose To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Methods Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Results Mean deviation angle with glasses at the start of occlusion treatment was 19.45±5.97 PD and decreased to 12.14±12.96 PD at 2 years after occlusion therapy (p<0.01). After occlusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). Conclusions There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia. PMID:17804922

  5. A dynamic traction splint for the management of extrinsic tendon tightness.

    PubMed

    Dovelle, S; Heeter, P K; Phillips, P D

    1987-02-01

    The dynamic traction splint designed by therapists at Walter Reed Army Medical Center is used for the management of extrinsic extensor tendon tightness commonly seen in brachial plexus injuries and traumatic soft tissue injuries of the upper extremity. The two components of the splint allow for simultaneous maximum flexion of the MCP and IP joints. This simple and economical splint provides an additional modality to any occupational therapy service involved in the management of upper extremity disorders.

  6. The effect of occlusion therapy on motion perception deficits in amblyopia.

    PubMed

    Giaschi, Deborah; Chapman, Christine; Meier, Kimberly; Narasimhan, Sathyasri; Regan, David

    2015-09-01

    There is growing evidence for deficits in motion perception in amblyopia, but these are rarely assessed clinically. In this prospective study we examined the effect of occlusion therapy on motion-defined form perception and multiple-object tracking. Participants included children (3-10years old) with unilateral anisometropic and/or strabismic amblyopia who were currently undergoing occlusion therapy and age-matched control children with normal vision. At the start of the study, deficits in motion-defined form perception were present in at least one eye in 69% of the children with amblyopia. These deficits were still present at the end of the study in 55% of the amblyopia group. For multiple-object tracking, deficits were present initially in 64% and finally in 55% of the children with amblyopia, even after completion of occlusion therapy. Many of these deficits persisted in spite of an improvement in amblyopic eye visual acuity in response to occlusion therapy. The prevalence of motion perception deficits in amblyopia as well as their resistance to occlusion therapy, support the need for new approaches to amblyopia treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. GABA and glutamate levels in occlusal splint-wearing males with possible bruxism.

    PubMed

    Dharmadhikari, Shalmali; Romito, Laura M; Dzemidzic, Mario; Dydak, Ulrike; Xu, Jun; Bodkin, Cynthia L; Manchanda, Shalini; Byrd, Kenneth E

    2015-07-01

    The inhibitory neurotransmitter γ-aminobutyric acid (GABA) plays an important role in the pathophysiology of anxiety behavioural disorders such as panic disorder and post-traumatic stress disorder and is also implicated in the manifestation of tooth-grinding and clenching behaviours generally known as bruxism. In order to test whether the stress-related behaviours of tooth-grinding and clenching share similar underlying mechanisms involving GABA and other metabolites as do anxiety-related behavioural disorders, we performed a Magnetic Resonance Spectroscopy (MRS) study for accurate, in vivo metabolite quantification in anxiety-related brain regions. MRS was performed in the right hippocampus and right thalamus involved in the hypothalamic-pituitary-adrenal axis system, together with a motor planning region (dorsal anterior cingulate cortex/pre-supplementary motor area) and right dorsolateral prefrontal cortex (DLPFC). Eight occlusal splint-wearing men (OCS) with possible tooth-grinding and clenching behaviours and nine male controls (CON) with no such behaviour were studied. Repeated-measures ANOVA showed significant Group×Region interaction for GABA+ (p = 0.001) and glutamate (Glu) (p = 0.031). Between-group post hoc ANOVA showed significantly lower levels of GABA+ (p = 0.003) and higher levels of Glu (p = 0.002) in DLPFC of OCS subjects. These GABA+ and Glu group differences remained significant (GABA+, p = 0.049; Glu, p = 0.039) after the inclusion of anxiety as a covariate. Additionally, GABA and Glu levels in the DLPFC of all subjects were negatively related (Pearson's r = -0.75, p = 0.003). These findings indicate that the oral behaviours of tooth-grinding and clenching, generally known as bruxism, may be associated with disturbances in brain GABAergic and glutamatergic systems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old.

    PubMed

    Megbelayin, E; Ekpenyong, S M; Azunobi, J; Ejiro, G

    2014-03-01

    To report a reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old. Case report. Eye clinic of a University Teaching Hospital in a metropolitan city. an index patient. Occlusion therapy. Post occlusion visual acuity. Presenting unaided visual acuity of right eye: 6/6, left eye: 4/60. Refraction result was: right eye: -0.50DS (6/6), left eye: -3.50DS (6/18). Following day time occlusion therapy of at least 6 hours for about 4 weeks, subjective refraction was: right eye: -0.5DS (6/5), left eye: -3.50DS (6/6(+3)). The remarkable improvement in vision at age 25 years of a patient with myopic anisometropic amblyopia shows that occlusion therapy might still be useful long after amblyogenic period.

  9. Shin splints - self-care

    MedlinePlus

    ... self-care; Tibial periostitis - self-care; Posterior tibial shin splints - self-care ... Shin splints are an exercise problem. You get shin splints from overloading your leg muscles, tendons or shin ...

  10. History of intranasal splints.

    PubMed

    Lau, J; Elhassan, H A; Singh, N

    2018-03-01

    Intranasal splints have long been utilised as a post-operative adjunct in septoplasty, intended to reduce the risk of adhesions and haematoma formation, and to maintain alignment during healing. A Medline literature review of the history and evolution of intranasal splint materials and designs was performed. Advantages and disadvantages of various splints are discussed. Intranasal splints fashioned from X-ray film were first reported in 1955. Since then, a variety of materials have been utilised, including polyethylene coffee cup lids, samarium cobalt magnets and dental utility wax. Most contemporary splints are produced from silicon rubber or polytetrafluoroethylene (Teflon). Designs have varied in thickness, flexibility, shape, absorption and the inclusion of built-in airway tubes. Future directions in splint materials and designs are discussed. Intranasal splints have steadily evolved since 1955, with numerous novel innovations. Despite their simplicity, they play an important role in nasal surgery and will continue to evolve over time.

  11. Patching compliance with full-time vs. part-time occlusion therapy.

    PubMed

    Kane, Jessica; Biernacki, Ron; Fraine, Lisa; Fukuda, Neva; Haskins, Kelsie; Morrison, David G

    2013-01-01

    Amblyopia is commonly treated with part-time occlusion (PTO) therapy. We have made two anecdotal observations regarding this therapy. First, children undergoing full-time occlusion seem to have better success and compliance rates. Secondly, a subset of children exists that fail PTO but can improve with more aggressive therapy. A retrospective review where treatment, visual outcome, and compliance scores were recorded. Compliance was graded on percent adherence reported by family. Patients scored “1” (for no compliance), “2” (for 1–25% of prescribed treatment performed), “3” (for 26–50%), “4” (for 51–75%), or “5” (for 76–100%). Seventy-six children were enrolled in the study: forty-five were treated with part-time occlusion, twenty-two were treated with full time occlusion (FTO), and nine had a history of failed PTO and were subsequently treated with FTO. Visual outcomes for FTO versus PTO were not statistically significant (P = 0.82). However, compliance rates in FTO were significantly better (P = 0.02). Of the nine patients that failed PTO, four improved an average of three lines with full-time occlusion, and five had no change with more aggressive patching. This study confirms previous reports of similar visual outcomes between PTO and FTO. However, compliance rates for FTO seem to be higher and some children who have failed PTO may improve with FTO.

  12. Serious infectious complications related to extremity cast/splint placement in children.

    PubMed

    Delasobera, B Elizabeth; Place, Rick; Howell, John; Davis, Jonathan E

    2011-07-01

    Extremity injuries necessitating splinting or casting are commonly seen in the emergency department (ED) setting. Subsequently, it is not uncommon for patients to present to the ED with complaints related to an extremity cast or splint. To present a literature-based approach to the identification and initial management of patients with possible infectious cast/splint complications in the ED setting. We present two cases of serious infectious complications arising from extremity cast/splint placement seen in a single pediatric ED: a case of toxic shock syndrome in an 8-year-old child, and a case of necrotizing fasciitis resulting in upper extremity amputation in a 3-year-old child. A wide spectrum of potential extremity cast/splint infectious complications may be seen, which include limb- or life-threatening infections such as toxic shock syndrome and necrotizing fasciitis. Simply considering these diagnoses, and removing the cast or splint to carefully inspect the affected extremity, are potential keys to early identification and optimal outcome of cast/splint complications. It is also prudent to maintain particular vigilance when treating a patient with a water-exposed cast, which may lead to moist padding, skin breakdown, and potential infection. In patients with suspected serious infections, aggressive fluid management and antibiotic therapy should be initiated and appropriate surgical consultation obtained without delay. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. BOLD fMRI and DTI in strabismic amblyopes following occlusion therapy.

    PubMed

    Gupta, Shikha; Kumaran, Senthil S; Saxena, Rohit; Gudwani, Sunita; Menon, Vimala; Sharma, Pradeep

    2016-08-01

    Evaluation of brain cluster activation using the functional magnetic resonance imaging (fMRI) and diffusion tensor imaging (DTI) was sought in strabismic amblyopes. In this hospital-based case-control cross-sectional study, fMRI and DTI were conducted in strabismic amblyopes before initiation of any therapy and after visual recovery following the administration of occlusion therapy. FMRI was performed in 10 strabismic amblyopic subjects (baseline group) and in 5 left strabismic amblyopic children post-occlusion therapy after two-line visual improvement. Ten age-matched healthy children with right ocular dominance formed control group. Structural and functional MRI was carried out on 1.5T MR scanner. The visual task consisted of 8 Hz flickering checkerboard with red dot and occasional green dot. Blood-oxygen-level-dependent (BOLD) fMRI was analyzed using statistical parametric mapping and DTI on NordicIce (NordicNeuroLab) softwares. Reduced occipital activation was elicited when viewing with the amblyopic eye in amblyopes. An 'ipsilateral to viewing eye' pattern of calcarine BOLD activation was observed in controls and left amblyopes. Activation of cortical areas associated with visual processing differed in relation to the viewing eye. Following visual recovery on occlusion therapy, enhanced activity in bilateral hemispheres in striate as well as extrastriate regions when viewing with either eye was seen. Improvement in visual acuity following occlusion therapy correlates with hemodynamic activity in amblyopes.

  14. Shin splints (image)

    MedlinePlus

    Shin splints is the common name for the medical condition called medial tibial stress syndrome in which pain ... the lower leg muscles' attachment to the tibia. Shin splints are typically caused from intense or vigorous athletic ...

  15. Therapy challenges for athletes: splinting options.

    PubMed

    Russell, Carrie R

    2015-01-01

    Therapists treating athletes with hand and wrist injuries may be involved in all stages of recovery, from the acute phase to return to sport. This article gives case examples of how creative use of custom and commercially available orthoses, splints, tape, and braces can augment various stages of recovery. Understanding the specific demands of the sport and respect for the standards of care are imperative to fabricating or fitting an athlete with the best device or customization of the athlete's own equipment for a safe return to sport. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Shin Splints 101: Explaining Shin Splints to Young Runners

    ERIC Educational Resources Information Center

    Newlin, Dana; Smith, Darla S.

    2011-01-01

    Shin splints are a common but often confusing injury. Sources disagree on both the cause of the injury and the anatomical source of the pain. Some blame shin splints on foot pronation, footstrike pattern, or arch height. Regardless of what causes the condition, it affects many runners, beginning in some at a young age. Young runners often have…

  17. Proximal Interphalangeal Joint Extension Block Splint

    PubMed Central

    Abboudi, Jack; Jones, Christopher M.

    2016-01-01

    Background: Extension block splinting of the proximal interphalangeal (PIP) joint is a simple and useful treatment option although the practical application of this technique has remained undefined in the literature. Methods: This article provides a step-by-step technique for the construction of a reliable PIP extension block splint and also reviews basic indications for treatment with a PIP extension block splint as well as other PIP extension block splint designs. Results: The proposed splint design outlined in this article is reliable, easy to reproduce and easy for patients to manage when treated with a PIP extension block splint. Conclusions: PIP extension block splinting has a role for certain injuries and certain post-operative protocols. A reliable splint design that is easy to manage makes this treatment choice more attractive to the surgeon and the patient. PMID:27390555

  18. Effect of Restorative Configurations and Occlusal Schemes on Strain Levels in Bone Surrounding Implants.

    PubMed

    Block, Jonathan; Matalon, Shlomo; Tanase, Gabriela; Ormianer, Zeev

    2017-08-01

    This study investigated strain levels during and after implant insertion, and during and after simulated mastication, in splinted and nonsplinted restorations with different occlusal schemes. Fresh bovine bone resembling type I jawbone was collected. Strain gauges were placed at each implant's neck, one horizontally and one vertically. Strains at and after implant insertion were recorded. The restoration was loaded with cyclic load simulating mastication. Loading and residual strains were recorded for 6 experimental loading types. At and after implant insertion, high horizontal strains were measured. Full splint loading presented higher vertical compared with horizontal strains (P < 0.05). Segmented cross-arch splint showed higher horizontal strains (P < 0.05). Premolar loading guidance presented the most favorable loading and residual strain results (P < 0.05). Splinting implant restorations may reduce strain levels at implant neck area and provide preferable strain distribution during cyclic loading.

  19. Efficiency of occlusion therapy for management of amblyopia in older children.

    PubMed

    Brar, Gagandeep S; Bandyopadhyay, Supratik; Kaushik, Sushmita; Raj, Surishti

    2006-12-01

    To analyse results of full time occlusion therapy for amblyopia in children older than 6 years. This was a retrospective consecutive case series analysis of children treated for amblyopia at a tertiary care center. All children received full time occlusion (FTO) for the dominant eye. Eighty-eight children older than 6 years at the time of initiation of therapy were included. Age at initiation of therapy ranged from 6 to 20 years (9.45 +/- 3.11 years). Forty-two children (47.7%) had strabismic amblyopia, 37 (42.0%) had anisometropic amblyopia and 9 (10.2%) had a combination of strabismic and anisometropic amblyopia. Eighty out of 88 eyes (90.0%) had improvement in visual acuity following FTO. Visual acuity (VA) improved from 0.82 +/- 0.34 at presentation to 0.42 +/- 0.34 (P < 0.001) after FTO. In children with strabismic amblyopia, VA improved from 0.81 +/- 0.42 to 0.42 +/- 0.39 (P <0.001). In children with anisometropic amblyopia, visual acuity of the amblyopic eye improved fron 0.82 +/- 0.24 to 0.36 +/- 0.29 (P< 0.001) following FTO. Out of 13 children older than 12 years, only 6 children (46.1%) had improvement in VA. Mean follow-up after complete stoppage of occlusion was 8.37 +/- 1.78 months. Occlusion therapy yields favorable results in strabismic and/or anisometropic amblyopia, even when initiated for the first time after 6 years of age. After 12 years of age, some children may still respond to occlusion of the dominant eye.

  20. Pattern Visual Evoked Potential as a Predictor of Occlusion Therapy for Amblyopia

    PubMed Central

    Chung, Woosuk; Hong, Samin; Lee, Jong Bok

    2008-01-01

    Purpose This study was conducted to investigate the role of the pattern visual evoked potential (pVEP) as a predictor of occlusion therapy for patients with strabismic, anisometropic, and isometropic amblyopia. The secondary aim was to compare the characteristics of pVEP between strabismic and anisometropic amblyopia. Methods This retrospective comparative case series included 120 patients who had received occlusion therapy or a glasses prescription for correction of strabismic, anisometropic, and isometropic amblyopia (20 patients had strabismic amblyopia, 41 patients had anisometropic amblyopia, and 59 patients had isometropic amblyopia). For each patient, the value of the P100 latency on pVEP at the time of the initial diagnosis of amblyopia was collected. Subsequently, the P100 latency was compared according to types of amblyopia. Fifty of 120 patients (7 patients with strabismic amblyopia, 21 patients with anisometropic amblyopia, and 22 patients with isometropic amblyopia) who were followed-up for longer than 6 months were divided into two groups based on the value of their P100 latency (Group 1, P100 latency 120 msec or less; Group 2, P100 latency longer than 120 msec.) The amount of visual improvement after occlusion therapy or glasses was compared between two study groups. Results The mean P100 latency was 119.7±25.2 msec in eyes with strabismic amblyopia and 111.9±17.8 msec in eyes with non-strabismic (anisometropic or isometropic) amblyopia (p=0.213). In Group 1, the mean visual improvement after occlusion therapy or glasses was 3.69±2.14 lines on Dr. Hahn's standard test chart; in Group 2, the mean improvement was 2.27±2.21 lines (p=0.023). Conclusions The P100 latency on pVEP at the time of initial diagnosis was significantly related to the visual improvement after occlusion therapy or glasses in patients with strabismic, anisometropic, and isometropic amblyopia. Therefore, it was presumed that patients with a delayed P100 latency might have less

  1. Pattern visual evoked potential as a predictor of occlusion therapy for amblyopia.

    PubMed

    Chung, Woosuk; Hong, Samin; Lee, Jong Bok; Han, Sueng-Han

    2008-12-01

    This study was conducted to investigate the role of the pattern visual evoked potential (pVEP) as a predictor of occlusion therapy for patients with strabismic, anisometropic, and isometropic amblyopia. The secondary aim was to compare the characteristics of pVEP between strabismic and anisometropic amblyopia. This retrospective comparative case series included 120 patients who had received occlusion therapy or a glasses prescription for correction of strabismic, anisometropic, and isometropic amblyopia (20 patients had strabismic amblyopia, 41 patients had anisometropic amblyopia, and 59 patients had isometropic amblyopia). For each patient, the value of the P100 latency on pVEP at the time of the initial diagnosis of amblyopia was collected. Subsequently, the P100 latency was compared according to types of amblyopia. Fifty of 120 patients (7 patients with strabismic amblyopia, 21 patients with anisometropic amblyopia, and 22 patients with isometropic amblyopia) who were followed-up for longer than 6 months were divided into two groups based on the value of their P100 latency (Group 1, P100 latency 120 msec or less; Group 2, P100 latency longer than 120 msec.) The amount of visual improvement after occlusion therapy or glasses was compared between two study groups. The mean P100 latency was 119.7+/-25.2 msec in eyes with strabismic amblyopia and 111.9+/-17.8 msec in eyes with non-strabismic (anisometropic or isometropic) amblyopia (p=0.213). In Group 1, the mean visual improvement after occlusion therapy or glasses was 3.69+/-2.14 lines on Dr. Hahn's standard test chart; in Group 2, the mean improvement was 2.27+/-2.21 lines (p=0.023). The P100 latency on pVEP at the time of initial diagnosis was significantly related to the visual improvement after occlusion therapy or glasses in patients with strabismic, anisometropic, and isometropic amblyopia. Therefore, it was presumed that patients with a delayed P100 latency might have less visual improvement after

  2. The pathology of shin splints.

    PubMed

    Kues, J M

    1990-01-01

    The purpose of this review is to critically evaluate experimental evidence describing the pathology associated with shin splints. Shin splints are defined as medial or posteromedial leg pain which is brought about by walking, running, or related activities and which decreases with rest. The evidence indicates that shin splints may be due to pathology of the posteromedial tibial cortex, the periosteum of the posteromedial tibia, or the crural fascia of the deep posterior compartment of the leg. Research is needed to determine if increased pressure in the deep posterior compartment of the leg or pathology of the muscles, tendons, or interosseous membrane of the leg are associated with shin splints. J Orthop Sports Phys Ther 1990;12(3):115-121.

  3. Lateral compression open cap splint with circummandibular wiring for management of pediatric mandibular fractures: a retrospective audit of 10 cases.

    PubMed

    Bhola, Nitin; Jadhav, Anendd; Borle, Rajiv; Khemka, Gaurav; Adwani, Nitin; Bhattad, Mayur

    2014-03-01

    Mandibular fractures are relatively less frequent in children when compared to adults. Pediatric patients present a unique challenge to maxillofacial surgeons in terms of their treatment planning and in their functional needs. We currently describe our experience with lateral compression open cap splint with circummandibular wiring as a treatment modality which involves fewer risks in treating pediatric symphysis/parasymphysis/body mandibular fractures. A retrospective analysis of pediatric patients with mandibular symphysis/parasymphysis/body fractures operated from January 2007 to January 2012 was performed. Clinical photographs and orthopantomogram assessment at the time of presentation, after treatment, and at 6 months postoperatively were evaluated. All the 10 patients were followed up until the period of 6 months, and none of them had any major complications. Postoperatively, there was satisfactory healing and union of fracture fragments in all the patients. Only one patient developed infection at submental region. The 6-month follow-up showed good occlusion, without interference in teeth eruption and no signs of temporomandibular joint problems. Lateral compression open cap splints for treatment of pediatric mandibular symphysis/parasymphysis/body fractures are reliable treatment modalities with regard to occlusion-guided fracture reduction.

  4. [Importance of occlusion therapy for amblyopia in partial unilateral congenital cataracts that are discovered late].

    PubMed

    Denion, E; Dedes, V; Bonne, M; Labalette, P; Berger, C; Guilbert, F; Bouckehove, S; Rouland, J-F

    2004-11-01

    The aim of this study is to investigate the importance of occlusion therapy for amblyopia in patients with partial unilateral congenital cataracts that were discovered after 24 months of age. A retrospective study was conducted on 11 patients, each of whom underwent a clinical examination including a cycloplegic refraction with atropine. The average age when the cataract was diagnosed was 35 months. The average distance visual acuity was 6/78 and the average near visual acuity was 35/175. Occlusion therapy using adhesive patches was started after refractive error correction. In two cases, observance was mediocre. Ametropia was found in every patient, with anisometropia in nine patients (alpha < 0.02). This anisometropia included an astigmatism that was always greater on the side with the cataract (alpha < 0.001), averaging 2.7 diopters. After occlusion therapy for amblyopia, the average visual acuity significantly improved to 6/22 in distance vision (alpha < 0.02) and 35/45 in near vision (alpha < 0.01). The average follow-up period was 28 months (5-60 months). Amblyopia is related to lens opacities as well as frequently associated anisometropia. Functional improvement is greater in near vision than in distance vision. With occlusion therapy for amblyopia, accommodation is preserved. This factor is of utmost importance as near vision is preferential in young children. This study provides an opportunity to recall the importance of refraction and occlusion therapy for amblyopia, which must be systematically attempted in cases of partial unilateral congenital cataracts before considering a surgical procedure.

  5. Binocular Rivalry Measured 2 Hours After Occlusion Therapy Predicts the Recovery Rate of the Amblyopic Eye in Anisometropic Children.

    PubMed

    Lunghi, Claudia; Morrone, Maria Concetta; Secci, Jacopo; Caputo, Roberto

    2016-04-01

    Recent studies on adults have shown that short-term monocular deprivation boosts the deprived eye signal in binocular rivalry, reflecting homeostatic plasticity. Here we investigate whether homeostatic plasticity is present also during occlusion therapy for moderate amblyopia. Binocular rivalry and visual acuity (using Snellen charts for children) were measured in 10 children (mean age 6.2 ± 1 years) with moderate anisometropic amblyopia before the beginning of treatment and at four intervals during occlusion therapy (2 hours, 1, 2, and 5 months). Visual stimuli were orthogonal gratings presented dichoptically through ferromagnetic goggles and children reported verbally visual rivalrous perception. Bangerter filters were applied on the spectacle lens over the best eye for occlusion therapy. Two hours of occlusion therapy increased the nonamblyopic eye predominance over the amblyopic eye compared with pretreatment measurements, consistent with the results in adults. The boost of the nonamblyopic eye was still present after 1 month of treatment, steadily decreasing afterward to reach pretreatment levels after 2 months of continuous occlusion. Across subjects, the increase in nonamblyopic eye predominance observed after 2 hours of occlusion correlated (rho = -0.65, P = 0.04) with the visual acuity improvement of the amblyopic eye measured after 2 months of treatment. Homeostatic plasticity operates during occlusion therapy for moderate amblyopia and the increase in nonamblyopic eye dominance observed at the beginning of treatment correlates with the amblyopic eye recovery rate. These results suggest that binocular rivalry might be used to monitor visual cortical plasticity during occlusion therapy, although further investigations on larger clinical populations are needed to validate the predictive power of the technique.

  6. Binocular Rivalry Measured 2 Hours After Occlusion Therapy Predicts the Recovery Rate of the Amblyopic Eye in Anisometropic Children

    PubMed Central

    Lunghi, Claudia; Morrone, Maria Concetta; Secci, Jacopo; Caputo, Roberto

    2016-01-01

    Purpose Recent studies on adults have shown that short-term monocular deprivation boosts the deprived eye signal in binocular rivalry, reflecting homeostatic plasticity. Here we investigate whether homeostatic plasticity is present also during occlusion therapy for moderate amblyopia. Methods Binocular rivalry and visual acuity (using Snellen charts for children) were measured in 10 children (mean age 6.2 ± 1 years) with moderate anisometropic amblyopia before the beginning of treatment and at four intervals during occlusion therapy (2 hours, 1, 2, and 5 months). Visual stimuli were orthogonal gratings presented dichoptically through ferromagnetic goggles and children reported verbally visual rivalrous perception. Bangerter filters were applied on the spectacle lens over the best eye for occlusion therapy. Results Two hours of occlusion therapy increased the nonamblyopic eye predominance over the amblyopic eye compared with pretreatment measurements, consistent with the results in adults. The boost of the nonamblyopic eye was still present after 1 month of treatment, steadily decreasing afterward to reach pretreatment levels after 2 months of continuous occlusion. Across subjects, the increase in nonamblyopic eye predominance observed after 2 hours of occlusion correlated (rho = −0.65, P = 0.04) with the visual acuity improvement of the amblyopic eye measured after 2 months of treatment. Conclusions Homeostatic plasticity operates during occlusion therapy for moderate amblyopia and the increase in nonamblyopic eye dominance observed at the beginning of treatment correlates with the amblyopic eye recovery rate. These results suggest that binocular rivalry might be used to monitor visual cortical plasticity during occlusion therapy, although further investigations on larger clinical populations are needed to validate the predictive power of the technique. PMID:27046118

  7. Displacement of screw-retained splinted and nonsplinted restorations into implants with conical internal connections.

    PubMed

    Yilmaz, Burak; Seidt, Jeremy D; Clelland, Nancy L

    2014-01-01

    Variable abutment displacement could potentially affect proximal contacts, incisal edge position, or occlusion of implant-supported prostheses. This study aimed to measure and compare displacements of splinted and nonsplinted restorations into implants featuring internal conical connections as screws were tightened by hand or by torque driver. A stereolithic resin model was printed using computed tomography data from a patient missing mandibular left first and second molars. Two 5.0 × 11-mm implants were placed in the edentulous site using a surgical guide. Two sets (splinted and nonsplinted) of gold screw-retained prostheses were made indirectly to fit the implants in the stereolithic model representing the patient. The axial position of the crowns relative to a fixed location on the model was recorded following hand tightening using the three-dimensional image correlation technique and image correlation software. A pair of high-resolution digital cameras provided a synchronized view of the model during the experiment. Relative crown positions were again recorded after tightening with a torque driver to 25 Ncm. Testing was repeated randomly three times for each set of crowns. Displacement data after torque tightening were compared using a factorial analysis of variance with JMP 9.0 software (SAS) followed by a Tukey-Kramer post hoc test (α = .05). Interproximal contacts were evaluated using an 8-μm tin foil shim after tightening by hand and torque driver. Displacements for splinted and nonsplinted restorations differed only in a buccal direction. The nonsplinted crowns displaced significantly more than splinted crowns. Discernible differences were observed for the tin foil shim when dragged through proximal contacts following hand versus torque tightening. Differences between screw tightening by hand or torque driver should be taken into consideration during laboratory and clinical adjustments to prevent esthetic and functional complications.

  8. Factors affecting the stability of visual function following cessation of occlusion therapy for amblyopia.

    PubMed

    Tacagni, Daniel J; Stewart, Catherine E; Moseley, Merrick J; Fielder, Alistair R

    2007-06-01

    To identify factors that predict which children with amblyopia are at greatest risk of regression of visual acuity (VA) following the cessation of occlusion therapy. A retrospective analysis was performed of 182 children (mean age at cessation of treatment; 5.9+/-1.6 years) who had undergone occlusion therapy for unilateral amblyopia, and had been followed up at least once within 15 months of cessation. Statistical analysis was used to identify whether change in VA following treatment cessation had any association with various factors, including the child's age, type of amblyopia, degree of anisometropia, initial severity of amblyopia, binocular vision status, length and dose of occlusion therapy, and VA response to treatment. At 1 year, follow-up from treatment cessation, children with "mixed" amblyopia (both anisometropia and strabismus) demonstrated significantly (p=0.03) greater deterioration in VA (0.11+/-0.11 log units) than children with only anisometropia (0.02+/-0.08 log units) or only strabismus (0.05+/-0.10 log units). However, none of the other factors investigated were found to be significant predictors. This study supports previous research that it is possible to identify those children most at risk of deterioration in VA following cessation of occlusion therapy. The presence of mixed amblyopia was the only risk factor identified in this study. Management of amblyopia should take this into account, with a more intensive follow-up recommended for those with both anisometropia and strabismus (mixed) amblyopia.

  9. Shin splints--a review of terminology.

    PubMed

    Batt, M E

    1995-01-01

    This review is intended to improve the understanding of and rationale for the use of the term shin splints. Currently the term is used widely and variably, with little consensus of definition. Broadly, it denotes the occurrence of exertional lower leg pain; more specifically, it refers to an anatomical site of periostitis. The literature reports a multiplicity of descriptions and definitions of shin splints resultant from the complex etiologies and differing perceptions of these conditions. It is proposed that the term shin splint be recognized as generic, rather than diagnostic, and that specific conditions that currently exist under this term be differentiated. The etiology and interaction of these related conditions are considered, and a classification based on the current literature is given of conditions currently termed shin splints, providing a rationale for their clinical presentations, investigative findings, and interactions.

  10. Occlusion dose monitoring in amblyopia therapy: status, insights, and future directions.

    PubMed

    Stewart, Catherine E; Moseley, Merrick J; Georgiou, Pantelis; Fielder, Alistair R

    2017-10-01

    Occlusion therapy remains the mainstay treatment of amblyopia, but its outcome is not assured or universally excellent. Many factors are known to influence treatment outcome, among which compliance is foremost. The occlusion dose monitor (ODM) removes one variable from the treatment equation, because it records the occlusion actually received by-rather than prescribed for-the child. Improvement observed can thus be quantitatively related to the patching received. This review summarizes the insights the ODM has provided to date particularly in elucidating the dose-response relationship. We are entering the era of personalized ophthalmology in which treatments will be tailored to the needs of the individual child and facilitated by the use of wearable monitors. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  11. Digital radiographic evaluation of alveolar bone loss, density and lamina dura integrity on post splinting mandibular anterior with chronic periodontitis

    NASA Astrophysics Data System (ADS)

    Rafini, F.; Priaminiarti, M.; Sukardi, I.; Lessang, R.

    2017-08-01

    The healing of periodontal splinting can be detected both with clinical and radiographic examination. In this study, the alveolar bone was evaluated by radiographic digital periapical analysis. Periodontal tooth splinting is periodontal support therapy used to prevent periodontal injury during repair and regeneration of periodontal therapy. Radiographic digital periapical analysis of alveolar bone in the mandibular anterior region with chronic periodontitis and 2/3 cervical bone loss after three months of periodontal splinting. Eighty four proximal site (43 mesial and 41 distal) from 16 patients with chronic periodontitis and treated with spinting were examined by taking periapical digital radiographic at day 1 and 91. The bone loss, bone density and utility of lamina dura were evaluated. The statistical analysis after three months evaluation using T-test for bone loss, Wilcoxon sign rank test for bone density and utility lamina dura showed no significantly differences (p<0.05) (p=0.44, 0.256 and 0.059). No radiographic change in bone loss, bone density and utility of lamina dura from chronic periodontitis with 2/3 alveolar bone loss after three months splinting.

  12. Treatment dose-response in amblyopia therapy: the Monitored Occlusion Treatment of Amblyopia Study (MOTAS).

    PubMed

    Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2004-09-01

    Amblyopia is the commonest visual disorder of childhood. Yet the contributions of the two principal treatments (spectacle wear and occlusion) to outcome are unknown. This study was undertaken to investigate the dose-response relationship of amblyopia therapy. The study comprised three distinct phases: baseline, in which repeat measures of visual function were undertaken to confirm the initial visual deficit; refractive adaptation: an 18-week period of spectacle wear with six weekly measurements of logarithm of the minimum angle of resolution (logMAR) visual acuity; occlusion: in which participants were prescribed 6 hours of "patching" per day. In the latter phase, occlusion was objectively monitored and logMAR visual acuity recorded at 2-week intervals until any observed gains had ceased. Data were obtained from 94 participants (mean age, 5.1 +/- 1.4 years) with amblyopia associated with strabismus (n = 34), anisometropia (n = 23), and both anisometropia and strabismus (n = 37). Eighty-six underwent refractive adaptation. Average concordance with patching was 48%. The relationship between logMAR visual acuity gain and total occlusion dose was monotonic and linear. Increasing dose rate beyond 2 h/d hastened the response but did not improve outcome. More than 80% of the improvement during occlusion occurred within 6 weeks. Treatment outcome was significantly better for children younger than 4 years (n = 17) than in those older than 6 years (n = 24; P = 0.0014). Continuous objective monitoring of the amount of patching therapy received has provided insight into the dose-response relationship of occlusion therapy for amblyopia. Patching is most effective within the first few weeks of treatment, even for those in receipt of a relatively small dose. Further studies are needed to elucidate the neural basis for the dose-response functions. Copyright Association for Research in Vision and Ophthalmology

  13. 21 CFR 874.4780 - Intranasal splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4780 Intranasal splint. (a) Identification... septum and the nasal cavity. It is placed in the nasal cavity after surgery or trauma. The intranasal splint is constructed from plastic, silicone, or absorbent material. (b) Classification. Class I (general...

  14. 21 CFR 874.4780 - Intranasal splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4780 Intranasal splint. (a) Identification... septum and the nasal cavity. It is placed in the nasal cavity after surgery or trauma. The intranasal splint is constructed from plastic, silicone, or absorbent material. (b) Classification. Class I (general...

  15. 21 CFR 874.4780 - Intranasal splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4780 Intranasal splint. (a) Identification... septum and the nasal cavity. It is placed in the nasal cavity after surgery or trauma. The intranasal splint is constructed from plastic, silicone, or absorbent material. (b) Classification. Class I (general...

  16. 21 CFR 874.4780 - Intranasal splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4780 Intranasal splint. (a) Identification... septum and the nasal cavity. It is placed in the nasal cavity after surgery or trauma. The intranasal splint is constructed from plastic, silicone, or absorbent material. (b) Classification. Class I (general...

  17. 21 CFR 874.4780 - Intranasal splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4780 Intranasal splint. (a) Identification... septum and the nasal cavity. It is placed in the nasal cavity after surgery or trauma. The intranasal splint is constructed from plastic, silicone, or absorbent material. (b) Classification. Class I (general...

  18. Electroacupuncture and splinting versus splinting alone to treat carpal tunnel syndrome: a randomized controlled trial.

    PubMed

    Chung, Vincent C H; Ho, Robin S T; Liu, Siya; Chong, Marc K C; Leung, Albert W N; Yip, Benjamin H K; Griffiths, Sian M; Zee, Benny C Y; Wu, Justin C Y; Sit, Regina W S; Lau, Alexander Y L; Wong, Samuel Y S

    2016-09-06

    The effectiveness of acupuncture for managing carpal tunnel syndrome is uncertain, particularly in patients already receiving conventional treatments (e.g., splinting). We aimed to assess the effects of electroacupuncture combined with splinting. We conducted a randomized parallel-group assessor-blinded 2-arm trial on patients with clinically diagnosed primary carpal tunnel syndrome. The treatment group was offered 13 sessions of electroacupuncture over 17 weeks. The treatment and control groups both received continuous nocturnal wrist splinting. Of 181 participants randomly assigned to electroacupuncture combined with splinting (n = 90) or splinting alone (n = 91), 174 (96.1%) completed all follow-up. The electroacupuncture group showed greater improvements at 17 weeks in symptoms (primary outcome of Symptom Severity Scale score mean difference [MD] -0.20, 95% confidence interval [CI] -0.36 to -0.03), disability (Disability of Arm, Shoulder and Hand Questionnaire score MD -6.72, 95% CI -10.9 to -2.57), function (Functional Status Scale score MD -0.22, 95% CI -0.38 to -0.05), dexterity (time to complete blinded pick-up test MD -6.13 seconds, 95% CI -10.6 to -1.63) and maximal tip pinch strength (MD 1.17 lb, 95% CI 0.48 to 1.86). Differences between groups were small and clinically unimportant for reduction in pain (numerical rating scale -0.70, 95% CI -1.34 to -0.06), and not significant for sensation (first finger monofilament test -0.08 mm, 95% CI -0.22 to 0.06). For patients with primary carpal tunnel syndrome, chronic mild to moderate symptoms and no indication for surgery, electroacupuncture produces small changes in symptoms, disability, function, dexterity and pinch strength when added to nocturnal splinting. Chinese Clinical Trial Register no. ChiCTR-TRC-11001655 (www.chictr.org.cn/showprojen.aspx?proj=7890); subsequently deposited in the World Health Organization International Clinical Trials Registry Platform (apps.who.int/trialsearch/Trial2.aspx

  19. Percutaneous endovascular therapy for symptomatic chronic total occlusion of the left subclavian artery.

    PubMed

    Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan

    2018-03-16

    Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.

  20. Asymmetrically pressing nasal splint for crooked nose deformity.

    PubMed

    Tugrul, Selahattin; Dogan, Remzi; Kocak, Ilker; Ozturan, Orhan

    2015-01-01

    Correcting crooked nose deformity is one of the most difficult procedure in rhinoplastic surgery. For that reason, the authors have been designed an asymmetrically pressing nasal splint. In this prospective study, the aim was to compare the effects of applying asymmetrically pressing nasal splint and normal symmetrically splint on the crooked nose. This study included 129 patients who were operated on for crooked nose deformity. Patients were divided into 2 groups. Normal symmetrically pressing nasal splint was applied to groups 1a (I type) and 1b (C type). Asymmetrically pressing nasal splint was applied to groups 2a (I type) and 2b (C type). All groups were compared according to deflection angle from the midline, the percentage of postoperative improvement, patient satisfaction with visual analog scale, and complication rate. I-type noses in both groups at postoperative angle values were reduced, and C-type noses in both groups at postoperative angle values were increased significantly compared with preoperative values. I-type noses of group 2 at postoperative angle values compared with group 1 were reduced, and C-type noses were increased in group 2 significantly. Patient satisfaction rate in group 2 were significantly better than in group 1. The closeness ratios to the ideal angles in group 1 were in "good" and "moderate" levels, whereas in group 2, it was in "excellent" level. There was no significant difference in complication rate in both groups. Asymmetrically pressing splint (novel design) showed increasing success rate clearly in crooked nose surgery than in normal splints.

  1. Electroacupuncture and splinting versus splinting alone to treat carpal tunnel syndrome: a randomized controlled trial

    PubMed Central

    Chung, Vincent C.H.; Ho, Robin S.T.; Liu, Siya; Chong, Marc K.C.; Leung, Albert W.N.; Yip, Benjamin H.K.; Griffiths, Sian M.; Zee, Benny C.Y.; Wu, Justin C.Y.; Sit, Regina W.S.; Lau, Alexander Y.L.; Wong, Samuel Y.S.

    2016-01-01

    Background: The effectiveness of acupuncture for managing carpal tunnel syndrome is uncertain, particularly in patients already receiving conventional treatments (e.g., splinting). We aimed to assess the effects of electroacupuncture combined with splinting. Methods: We conducted a randomized parallel-group assessor-blinded 2-arm trial on patients with clinically diagnosed primary carpal tunnel syndrome. The treatment group was offered 13 sessions of electroacupuncture over 17 weeks. The treatment and control groups both received continuous nocturnal wrist splinting. Results: Of 181 participants randomly assigned to electroacupuncture combined with splinting (n = 90) or splinting alone (n = 91), 174 (96.1%) completed all follow-up. The electroacupuncture group showed greater improvements at 17 weeks in symptoms (primary outcome of Symptom Severity Scale score mean difference [MD] −0.20, 95% confidence interval [CI] −0.36 to −0.03), disability (Disability of Arm, Shoulder and Hand Questionnaire score MD −6.72, 95% CI −10.9 to −2.57), function (Functional Status Scale score MD −0.22, 95% CI −0.38 to −0.05), dexterity (time to complete blinded pick-up test MD −6.13 seconds, 95% CI −10.6 to −1.63) and maximal tip pinch strength (MD 1.17 lb, 95% CI 0.48 to 1.86). Differences between groups were small and clinically unimportant for reduction in pain (numerical rating scale −0.70, 95% CI −1.34 to −0.06), and not significant for sensation (first finger monofilament test −0.08 mm, 95% CI −0.22 to 0.06). Interpretation: For patients with primary carpal tunnel syndrome, chronic mild to moderate symptoms and no indication for surgery, electroacupuncture produces small changes in symptoms, disability, function, dexterity and pinch strength when added to nocturnal splinting. Trial registration: Chinese Clinical Trial Register no. ChiCTR-TRC-11001655 (www.chictr.org.cn/showprojen.aspx?proj=7890); subsequently deposited in the World Health

  2. Polyvinyl siloxane: novel material for external nasal splinting.

    PubMed

    Jayakumar, N K; Rathnaprabhu, V; Ramesh, S; Parameswaran, A

    2016-01-01

    External nasal splinting is performed routinely after nasal bone fracture reductions, osteotomies, and rhinoplasties. Materials commonly used include plaster of Paris (POP), thermoplastic splints, self-adhesive padded aluminium splints, and Orthoplast, among many others. The disadvantages of these materials are described in this paper, and polyvinyl siloxane is recommended as an effective and more readily available alternative material to counter these pitfalls. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Evaluation of the Role of Monocular Video Game Play as an Adjuvant to Occlusion Therapy in the Management of Anisometropic Amblyopia.

    PubMed

    Singh, Archita; Sharma, Pradeep; Saxena, Rohit

    2017-07-01

    To evaluate the role of monocular video game play as an adjuvant to occlusion therapy in the treatment of anisometropic amblyopia. In a prospective randomized study design, 68 children with ages ranging from 6 to 14 years who had anisometropic amblyopia with a best corrected visual acuity (BCVA) in the amblyopic eye of better than 6/36 and worse than 6/12 and no manifest strabismus were recruited. They were randomly allocated into two groups: 34 children received 1 hour per day of video game play for the first month plus 6 hours per day of occlusion therapy (video game and occlusion group) and 34 children received 6 hours per day of occlusion therapy alone (occlusion only group). Patients were then evaluated at baseline and 1 and 3 months after treatment for BCVA, stereoacuity, and contrast sensitivity. In the video game and occlusion group, BCVA improved from 0.61 ± 0.12 logarithm of the minimum angle of resolution (logMAR) at baseline to 0.51 ± 0.14 logMAR (P = .001) at 1 month and 0.40 ± 0.15 logMAR (P = .001) at 3 months. In the occlusion only group, BCVA improved from 0.65 ± 0.09 logMAR at baseline to 0.60 ± 0.10 logMAR (P = .001) at 1 month and 0.48 ± 0.10 logMAR (P = .001) at 3 months. There was significantly more improvement in the video game and occlusion group compared to the occlusion only group (P = .003 at 1 month and P = .027 at 3 months). Video game play plus occlusion therapy enhances the visual recovery in anisometropic amblyopia. [J Pediatr Ophthalmol Strabismus. 2017;54(4):244-249.]. Copyright 2017, SLACK Incorporated.

  4. 21 CFR 872.3890 - Endodontic stabilizing splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endodontic stabilizing splint. 872.3890 Section 872.3890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3890 Endodontic stabilizing splint. (a...

  5. No Improvement in Sprint Performance With a Neuromuscular Fitted Dental Splint.

    PubMed

    Fischer, Henrike; Weber, Daniel; Beneke, Ralph

    2017-03-01

    Mouth guards protect against orofacial and dental injuries in sports. However, special fitted dental splints have been claimed to improve strength and speed and, therefore, to enhance athletic performance. To test the effects of a neuromuscular fitted dental splint in comparison with a habitual verticalizing splint and a no-splint condition on cycling sprint performance in the Wingate Anaerobic Test (WAnT). Twenty-three men (26.0 ± 2.0 y, 1.82 ± 0.06 m, 79.4 ± 7.7 kg) performed 3 WAnTs, 1 with the neuromuscular fitted splint, 1 with a habitual verticalized dental splint of the same height and material, and 1 under control conditions without any mouth guard, in randomized order separated by 1 wk. No differences between any splint conditions were found in any aspect of WAnT performance (time to peak power, peak power, minimum power, power drop, and average power). Moderate to nearly perfect correlations between all splint conditions in all WAnT outcomes with coefficients of variation between 1.3% and 6.6% were found. Irrespective of habitual verticalization or myocentric positioning, dental splints have no effects on any aspect of WAnT performance. Results are comparable to those of test-retest experiments.

  6. A comparison of conservative and invasive dental approaches in the treatment of tension-type headache.

    PubMed

    Troeltzsch, Markus; Messlinger, Karl; Brodine, Brian; Gassling, Volker; Troeltzsch, Matthias

    2014-10-01

    To investigate the efficacy of conservative dental treatment (occlusal splint and pharmacologic therapy) and invasive therapy (prosthetic restorations) in the treatment of tension-type headache (TTH). The study sample was composed of 70 patients who presented with symptomatic TTH and were assigned to three treatment groups according to their treatment needs. Group A (30 patients): a conservative treatment protocol with a combination of an occlusal splint and analgesic and muscle relaxant medication. Group B (10 patients): invasive prosthodontic procedures. Group C (30 patients): patients who refused any type of treatment but consented to the study served as a control group. Pain quality was measured with the Headache Impact Test (HIT-6). The statistical analysis was performed with the Wilcoxon rank test (P≤.05). Conservative treatment with splints and analgesic medication and invasive treatment by prosthetic rehabilitation relieved the TTH symptoms. The patients who received treatment experienced a significant reduction in their discomfort after 6 months (P≤.01), whereas the patients who refused therapy remained, on average, at the same pain level (P≤.117). In group A, the HIT-6 score was reduced for 26 patients, and in group B for 8 patients. In group C a reduction of HIT-6 scores was observed in 10 patients. Conservative or invasive occlusal adjustments may serve as a useful tool in the treatment of TTH.

  7. Improving education: just-in-time splinting video.

    PubMed

    Wang, Vincent; Cheng, Yu-Tsun; Liu, Deborah

    2016-06-01

    Just-in-time training (JITT) is an emerging concept in medical procedural education, but with few studies to support its routine use. Providing a brief educational intervention in the form of a digital video immediately prior to patient care may be an effective method to reteach knowledge for procedural techniques learned previously. Paediatric resident physicians were taught to perform a volar splint in a small workshop setting. Subsequently, they were asked to demonstrate their splinting proficiency by performing a splint on another doctor. Proficiency was scored on a five-point assessment tool. After 2-12 months, participants were asked to demonstrate their splinting proficiency on one of the investigators, and were divided into the control group (no further instruction) and the intervention group, which viewed a 3-minute JITT digital video demonstrating the splinting technique prior to performing the procedure. Thirty subjects were enrolled between August 2012 and July 2013, and 29 of 30 completed the study. The retest splinting time was not significantly different, but if the JITT group included watching the video, the total time difference was statistically significant: 3.86 minutes (control) versus 7.07 minutes (JITT) (95% confidence interval: 2.20-3.90 minutes). The average assessment score difference was 1.87 points higher for the JITT group, which was a statistically significant difference (95% confidence interval: 1.00-3.00). Just-in-time training is an emerging concept in medical procedural education JITT seems to be an effective tool in medical education for reinforcing previously learned skills. JITT may offer other possibilities for enhancing medical education. © 2015 John Wiley & Sons Ltd.

  8. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  9. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  10. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  11. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  12. 21 CFR 874.5800 - External nasal splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false External nasal splint. 874.5800 Section 874.5800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5800 External nasal splint. (a...

  13. 21 CFR 890.3675 - Denis Brown splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Denis Brown splint. 890.3675 Section 890.3675 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3675 Denis Brown splint. (a...

  14. 21 CFR 890.3675 - Denis Brown splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Denis Brown splint. 890.3675 Section 890.3675 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3675 Denis Brown splint. (a...

  15. 21 CFR 890.3675 - Denis Brown splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Denis Brown splint. 890.3675 Section 890.3675 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3675 Denis Brown splint. (a...

  16. 21 CFR 890.3675 - Denis Brown splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Denis Brown splint. 890.3675 Section 890.3675 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3675 Denis Brown splint. (a...

  17. Comparison of the Thickness and Volume of the Macula and Fovea in Patients with Anisometropic Amblyopia Prior to and after Occlusion Therapy.

    PubMed

    Yoon, Dong Hee; Chun, Bo Young

    2018-02-01

    To compare the thickness of superior, temporal, inferior, and nasal macula and foveal thickness and volume in patients with anisometropic amblyopia prior to and after successful occlusion therapy using optical coherence tomography (OCT) measurement. Data were collected prospectively on 30 patients with unilateral anisometropic amblyopia from December 2006 to August 2007. All patients had anisometropia of 2.0 diopters or more. OCT scans were obtained for all patients at diagnosis. Occlusion therapy was then prescribed and OCT scans were obtained again at the time of successful occlusion therapy (defined as interocular difference of <0.1 log units). The Stratus OCT-3 was used to measure fovea thickness and volume and the thickness of superior, temporal, inferior, and nasal macula (within a diameter of 3 mm). Of 30 patients, 22 (mean age of 5.8 years) had successful resolution of amblyopia. The mean duration of occlusion was 11.24 months and mean best-corrected visual acuity at diagnosis was 0.35 ± 0.12 logarithm of the minimum angle of resolution. The mean thicknesses of the superior, temporal, inferior, and nasal macula prior to and after occlusion were not significantly different (p > 0.05). However, mean foveal volume prior to occlusion therapy (0.15 ± 0.02 mm³) decreased after occlusion (0.14 ± 0.01 mm³) with statistical significance (Wilcoxon signed rank test, p = 0.025). There was a meaningful decrease in foveal volume in patients with anisometropic amblyopia after successful occlusion therapy. Whether this decrease relates to visual improvement of the amblyopic eye remains to be determined. © 2018 The Korean Ophthalmological Society

  18. Hyperbaric oxygen therapy in combination with systemic treatment of sickle cell disease presenting as central retinal artery occlusion: a case report.

    PubMed

    Canan, Handan; Ulas, Burak; Altan-Yaycioglu, Rana

    2014-11-17

    We describe hyperbaric oxygen therapy for the treatment of central retinal artery occlusion in a young adult with sickle cell disease. A 25-year-old Turkish man with a history of sickle cell disease developed sudden painless loss of vision in the left eye and was hospitalized for diagnosis and treatment. Central retinal artery occlusion was diagnosed with retinal whitening, cherry red spot, and delayed arteriovenous transit on fluorescein angiography. He underwent exchange transfusion and hyperbaric oxygen therapy. In the following three months, his visual acuity improved to 20/30. In this present case with sickle cell disease, the visual acuity improved with hyperbaric oxygen therapy in addition to systemic therapy. The result of our case suggests that hyperbaric oxygen therapy may be beneficial in the treatment of central retinal artery occlusion.

  19. Magnetic resonance imaging in stress fractures and shin splints.

    PubMed

    Aoki, Yoshimitsu; Yasuda, Kazunori; Tohyama, Harukazu; Ito, Hirokazu; Minami, Akio

    2004-04-01

    The purpose of the current study was to determine whether stress fractures and shin splints could be discriminated with MRI in the early phase. Twenty-two athletes, who had pain in the middle or distal part of their leg during or after sports activity, were evaluated with radiographs and MRI scans. Stress fractures were diagnosed when consecutive radiographs showed local periosteal reaction or a fracture line, and shin splints were diagnosed in all the other cases. In all eight patients with stress fractures, an abnormally wide high signal in the localized bone marrow was the most detectable in the coronal fat-suppressed MRI scan. In 11 patients with shin splints, the coronal fat-suppressed MRI scans showed a linear abnormally high signal along the medial posterior surface of the tibia, and in seven patients with shin splints, the MRI scans showed a linear abnormally high signal along the medial bone marrow. No MRI scans of shin splints showed an abnormally wide high signal in the bone marrow as observed on MRI scans of stress fractures. This study showed that fat-suppressed MRI is useful for discrimination between stress fracture and shin splints before radiographs show a detectable periosteal reaction in the tibia.

  20. Sensitive and specific miRNA detection method using SplintR Ligase

    PubMed Central

    Jin, Jingmin; Vaud, Sophie; Zhelkovsky, Alexander M.; Posfai, Janos; McReynolds, Larry A.

    2016-01-01

    We describe a simple, specific and sensitive microRNA (miRNA) detection method that utilizes Chlorella virus DNA ligase (SplintR® Ligase). This two-step method involves ligation of adjacent DNA oligonucleotides hybridized to a miRNA followed by real-time quantitative PCR (qPCR). SplintR Ligase is 100X faster than either T4 DNA Ligase or T4 RNA Ligase 2 for RNA splinted DNA ligation. Only a 4–6 bp overlap between a DNA probe and miRNA was required for efficient ligation by SplintR Ligase. This property allows more flexibility in designing miRNA-specific ligation probes than methods that use reverse transcriptase for cDNA synthesis of miRNA. The qPCR SplintR ligation assay is sensitive; it can detect a few thousand molecules of miR-122. For miR-122 detection the SplintR qPCR assay, using a FAM labeled double quenched DNA probe, was at least 40× more sensitive than the TaqMan assay. The SplintR method, when coupled with NextGen sequencing, allowed multiplex detection of miRNAs from brain, kidney, testis and liver. The SplintR qPCR assay is specific; individual let-7 miRNAs that differ by one nucleotide are detected. The rapid kinetics and ability to ligate DNA probes hybridized to RNA with short complementary sequences makes SplintR Ligase a useful enzyme for miRNA detection. PMID:27154271

  1. Splint sterilization--a potential registration hazard in computer-assisted surgery.

    PubMed

    Figl, Michael; Weber, Christoph; Assadian, Ojan; Toma, Cyril D; Traxler, Hannes; Seemann, Rudolf; Guevara-Rojas, Godoberto; Pöschl, Wolfgang P; Ewers, Rolf; Schicho, Kurt

    2012-04-01

    Registration of preoperative targeting information for the intraoperative situation is a crucial step in computer-assisted surgical interventions. Point-to-point registration using acrylic splints is among the most frequently used procedures. There are, however, no generally accepted recommendations for sterilization of the splint. An appropriate method for the thermolabile splint would be hydrogen peroxide-based plasma sterilization. This study evaluated the potential deformation of the splint undergoing such sterilization. Deformation was quantified using image-processing methods applied to computed tomographic (CT) volumes before and after sterilization. An acrylic navigation splint was used as the study object. Eight metallic markers placed in the splint were used for registration. Six steel spheres in the mouthpiece were used as targets. Two CT volumes of the splint were acquired before and after 5 sterilization cycles using a hydrogen peroxide sterilizer. Point-to-point registration was applied, and fiducial and target registration errors were computed. Surfaces were extracted from CT scans and Hausdorff distances were derived. Effectiveness of sterilization was determined using Geobacillus stearothermophilus. Fiducial-based registration of CT scans before and after sterilization resulted in a mean fiducial registration error of 0.74 mm; the target registration error in the mouthpiece was 0.15 mm. The Hausdorff distance, describing the maximal deformation of the splint, was 2.51 mm. Ninety percent of point-surface distances were shorter than 0.61 mm, and 95% were shorter than 0.73 mm. No bacterial growth was found after the sterilization process. Hydrogen peroxide-based low-temperature plasma sterilization does not deform the splint, which is the base for correct computer-navigated surgery. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Aqua splint suture technique in isolated zygomatic arch fractures.

    PubMed

    Kim, Dong-Kyu; Kim, Seung Kyun; Lee, Jun Ho; Park, Chan Hum

    2014-04-01

    Various methods have been used to treat zygomatic arch fractures, but no optimal modality exists for reducing these fractures and supporting the depressed bone fragments without causing esthetic problems and discomfort for life. We developed a novel aqua splint and suture technique for stabilizing isolated zygomatic arch fractures. The objective of this study is to evaluate the effect of novel aqua splint and suture technique in isolated zygomatic arch fractures. Patients with isolated zygomatic arch fractures were treated by a single surgeon in a single center from January 2000 through December 2012. Classic Gillies approach without external fixation was performed from January 2000 to December 2003, while the novel technique has been performed since 2004. 67 consecutive patients were included (Classic method, n = 32 and Novel method, n = 35). An informed consent was obtained from all patients. The novel aqua splint and suture technique was performed by the following fashion: first, we evaluated intraoperatively the bony alignment by ultrasonography and then, reduced the depressed fracture surgically using the Gillies approach. Thereafter, to stabilize the fracture and obtain the smooth facial figure, we made an aqua splint that fit the facial contour and placed monofilament nonabsorbable sutures around the fractured zygomatic arch. The novel aqua splint and suture technique showed significantly correlated with better cosmetic and functional results. In conclusion, the aqua splint suture technique is very simple, quick, safe, and effective for stabilizing repositioned zygomatic arch fractures. The aqua splint suture technique can be a good alternative procedure in isolated zygomatic arch fractures.

  3. Hyperbaric oxygen therapy in combination with systemic treatment of sickle cell disease presenting as central retinal artery occlusion: a case report

    PubMed Central

    2014-01-01

    Introduction We describe hyperbaric oxygen therapy for the treatment of central retinal artery occlusion in a young adult with sickle cell disease. Case presentation A 25-year-old Turkish man with a history of sickle cell disease developed sudden painless loss of vision in the left eye and was hospitalized for diagnosis and treatment. Central retinal artery occlusion was diagnosed with retinal whitening, cherry red spot, and delayed arteriovenous transit on fluorescein angiography. He underwent exchange transfusion and hyperbaric oxygen therapy. In the following three months, his visual acuity improved to 20/30. Conclusions In this present case with sickle cell disease, the visual acuity improved with hyperbaric oxygen therapy in addition to systemic therapy. The result of our case suggests that hyperbaric oxygen therapy may be beneficial in the treatment of central retinal artery occlusion. PMID:25399776

  4. Postoperative dynamic extension splinting compared with fixation with Kirschner wires and static splinting in contractures of burned hands: a comparative study of 57 cases in 9 years.

    PubMed

    Tan, Onder; Atik, Bekir; Dogan, Ali; Uslu, Mustafa; Alpaslan, Suleyman

    2007-01-01

    Skin grafting is widely used for the treatment of postburn contractures. Their main disadvantage, a tendency to contract again, can be reduced and better outcomes achieved by postoperative splinting. In this study we compared the outcomes of dynamic and static splinting postoperatively. Of the 57 patients managed by split grafts, 36 (44 hands) had Kirschner (K) wires applied with static splints, whereas 21 (26 hands) had dynamic splinting. The mean age was 11 (range 2-37) and 15 (range 2-50) years in the two groups. Before and after the operation, basic hand functions were evaluated clinically, and the results analysed statistically. The mean follow-up times were 18 and 14 months respectively, and recurrence rates were 22% and 14%. We think that the postoperative dynamic splinting is superior to fixation with K-wires with or without static splints.

  5. Factors influencing visual rehabilitation after occlusion therapy in unilateral amblyopia in children.

    PubMed

    Menon, Vimla; Chaudhuri, Zia; Saxena, Rohit; Gill, Kulwant; Sachdeva, M M

    2005-12-01

    Amblyopia is one of the most common causes of visual impairment in adults and children, and visual loss may be permanent if not treated in time. Though many studies have been done on occlusion therapy which is the mainstay in the treatment of unilateral amblyopia, discrepancies exist in literature about quantification of treatment and follow up measures. The present study was undertaken to evaluate the factors responsible for the successful outcome of treatment and the optimum time required for the same in children with unilateral amblyopia. Baseline characteristics of 63 verbal patients with unilateral amblyopia (strabismic, anisometropic, mixed) referred to the Strabismus and Amblyopia Clinic at the Dr Rajendra Prasad Centre for Ophthalmic Sciences, New Delhi between September 2001 to December 2002 who improved to the desired level of visual acuity after treatment for amblyopia in the mentioned time period, were analyzed to assess for factors that directly or indirectly influenced the optimum visual rehabilitation and the average duration of therapy required for the same. The evaluation included assessment of the baseline best-corrected visual acuity (BCVA) and refractive status in both eyes, the age at presentation, the type of amblyopia present, fixation pattern in the amblyopic eye, inter-eye visual acuity difference, and evaluation of compliance through a parental diary system. Baseline BCVA in the amblyopic eye was similar in all the three groups. Patients with anisometropic amblyopia showed a quicker response to therapy. Compliance to treatment was the major factor affecting the overall time required for a successful outcome in most cases. The overall time required for the treatment to be successful (including the period of maintenance) was about 1,089 h. This hospital-based study showed that the average duration of occlusion therapy to achieve stable isoacuity was 7.2 months with an average occlusion of 6-7 h/day. Compliance to therapy was the most

  6. The flexibility controlling study for 3D printed splint

    NASA Astrophysics Data System (ADS)

    Li, Jianyou; Tanaka, Hiroya

    2017-04-01

    The 3D printed splint's light weight, ventilation and water proof are considered as significant improvement for patients' comfortableness. Somehow, the flexible material is required in the splint to avoid skin friction may cased by its rigid edge, but this would increase the complexity and timeconsuming. In this study, two main techniques to control the infilling densities and printing temperature are applied on printing splint prototype. The gradual increasing of infilling density from splint outside to inside would turn the partial strength from hard to flexible. Besides, higher printing temperature can also achieve stronger hardness after cooling. Such structural can provide high strength in outside surface to keep the immovable function, and give flexible touch of inside surface to decrease friction on the patient's skin.

  7. Patient's experience of treatment for sleep apnoea with a mandibular advancement splint.

    PubMed

    Bhamrah, Gurprit; Dhir, Arti; Cash, Alex; Ahmad, Sofia; Winchester, Lindsay J

    2015-10-01

    Obstructive sleep apnoea (OSA) is a well recognised clinical disorder in which there is narrowing and repeated collapse of the upper airway during sleep resulting in the cessation of breathing. Patients with mild to moderate sleep apnoea are often provided with mandibular advancement splint (MAS) therapy as a form of first line or definitive treatment. The aims of this audit were to evaluate patient satisfaction and success of MAS therapy. 93 patients diagnosed with sleep apnoea and suitable for a splint were recruited prospectively at Queen Victoria Hospital, East Grinstead between January 2009 and October 2010. A patient satisfaction questionnaire was developed by health professionals involved in the care of patients with sleep apnoea and assessed for face and content validity and reliability. Participants completed the questionnaire six weeks after the splint was fitted. 44% who previously experienced snoring now reported no snoring and 47% reported less snoring since wearing the MAS appliance. 69% reported complete resolution of sleep apnoea symptoms. 37% experienced aching teeth and 33% experienced having a dry throat when wearing the appliance. 86% of sleeping partners felt that their quality of sleep was improved following their partners treatment. The standards set for each criteria in this audit were met. MAS treatment has a key role to play in the management of obstructive sleep apnoea with high rates of patient satisfaction and the majority of patients partners reporting a significant improvement in their own and their partners sleep quality. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  8. Teaching Splinting Techniques Using a Just-in-Time Training Instructional Video.

    PubMed

    Cheng, Yu-Tsun; Liu, Deborah R; Wang, Vincent J

    2017-03-01

    Splinting is a multistep procedure that is seldom performed by primary care physicians. Just-in-time training (JITT) is an emerging teaching modality and can be an invaluable asset for infrequently performed procedures or in locations where teaching resources and trained professionals are limited. Our objective was to determine the utility of JITT for teaching medical students the short-arm (SA) volar splinting technique. This was a prospective randomized controlled pilot study. An instructional video on SA volar splinting was produced. Students viewed the video or had access to standard medical textbooks (control group) immediately before applying an SA volar splint. The students were assessed for the quality of the splint via a standard 6-point skills checklist. The times required for presplinting preparation and for completion of the splint were also measured. Just-in-time training group students scored higher on the splint checklist (mean [SD], 5.45 [1.06]; 95% confidence interval [CI], 4.99-5.92 vs mean [SD], 1.58 [1.12]; 95% CI, 1.04-2.12; P < 0.0001), had higher pass rates (73%; 95% CI, 53%-93% vs 0%; P < 0.0001), and required less time (minutes) for presplinting preparation (mean [SD], 7.86 [2.45]; 95% CI, 6.78-8.94 vs mean [SD], 9.89 [0.46]; 95% CI, 9.67-10.12; P < 0.0001) compared with the control group. No difference was seen in the time required to complete a splint, successful or not. In comparison with reading standard textbooks, watching a brief JITT instructional video before splinting yielded faster learning times combined with more successful procedural skills. The use of a JITT instructional video may have potential applications, including globally, as an alternative resource for teaching and disseminating procedural skills, such as SA volar splinting.

  9. Implant-supported mandibular splinting affects temporomandibular joint biomechanics.

    PubMed

    Zaugg, Balthasar; Hämmerle, Christoph H F; Palla, Sandro; Gallo, Luigi M

    2012-08-01

    Mandibular functional movements lead to complex deformations of bony structures. The aim of this study was to test whether mandibular splinting influences condylar kinematics and temporomandibular joint (TMJ) loading patterns. Six subjects were analyzed by means of dynamic stereometry during jaw opening-closing with mandibles unconstrained as well as splinted transversally by a cast metal bar fixed bilaterally to two implant pairs in the (pre)molar region. Statistical analysis was performed by means of ANOVAs for repeated measurements (significance level α=0.05). Transversal splinting reduced mandibular deformation during jaw opening-closing as measured between two implants in the (pre)molar region on each side of the mandible significantly by 54%. Furthermore, splinting significantly reduced the distance between lateral condylar poles (average displacement vector magnitude of each pole: 0.84±0.36 mm; average mediolateral displacement component: 45±28% of the magnitude) and led to a medial displacement of their trajectories as well as a mediolateral displacement of stress-field paths. During jaw opening-closing, splinting of the mandible leads to a significant reduction of mandibular deformation and intercondylar distance and to altered stress-field paths, resulting in changed loading patterns of the TMJ structures. © 2011 John Wiley & Sons A/S.

  10. Cell Therapy Applications for Retinal Vascular Diseases: Diabetic Retinopathy and Retinal Vein Occlusion.

    PubMed

    Park, Susanna S

    2016-04-01

    Retinal vascular conditions, such as diabetic retinopathy and retinal vein occlusion, remain leading causes of vision loss. No therapy exists to restore vision loss resulting from retinal ischemia and associated retinal degeneration. Tissue regeneration is possible with cell therapy. The goal would be to restore or replace the damaged retinal vasculature and the retinal neurons that are damaged and/or degenerating from the hypoxic insult. Currently, various adult cell therapies have been explored as potential treatment. They include mesenchymal stem cells, vascular precursor cells (i.e., CD34+ cells, hematopoietic cells or endothelial progenitor cells), and adipose stromal cells. Preclinical studies show that all these cells have a paracrine trophic effect on damaged ischemic tissue, leading to tissue preservation. Endothelial progenitor cells and adipose stromal cells integrate into the damaged retinal vascular wall in preclinical models of diabetic retinopathy and ischemia-reperfusion injury. Mesenchymal stem cells do not integrate as readily but appear to have a primary paracrine trophic effect. Early phase clinical trials have been initiated and ongoing using mesenchymal stem cells or autologous bone marrow CD34+ cells injected intravitreally as potential therapy for diabetic retinopathy or retinal vein occlusion. Adipose stromal cells or pluripotent stem cells differentiated into endothelial colony-forming cells have been explored in preclinical studies and show promise as possible therapies for retinal vascular disorders. The relative safety or efficacy of these various cell therapies for treating retinal vascular disorders have yet to be determined.

  11. Development of a computer-aided design software for dental splint in orthognathic surgery

    NASA Astrophysics Data System (ADS)

    Chen, Xiaojun; Li, Xing; Xu, Lu; Sun, Yi; Politis, Constantinus; Egger, Jan

    2016-12-01

    In the orthognathic surgery, dental splints are important and necessary to help the surgeon reposition the maxilla or mandible. However, the traditional methods of manual design of dental splints are difficult and time-consuming. The research on computer-aided design software for dental splints is rarely reported. Our purpose is to develop a novel special software named EasySplint to design the dental splints conveniently and efficiently. The design can be divided into two steps, which are the generation of initial splint base and the Boolean operation between it and the maxilla-mandibular model. The initial splint base is formed by ruled surfaces reconstructed using the manually picked points. Then, a method to accomplish Boolean operation based on the distance filed of two meshes is proposed. The interference elimination can be conducted on the basis of marching cubes algorithm and Boolean operation. The accuracy of the dental splint can be guaranteed since the original mesh is utilized to form the result surface. Using EasySplint, the dental splints can be designed in about 10 minutes and saved as a stereo lithography (STL) file for 3D printing in clinical applications. Three phantom experiments were conducted and the efficiency of our method was demonstrated.

  12. Development of a computer-aided design software for dental splint in orthognathic surgery

    PubMed Central

    Chen, Xiaojun; Li, Xing; Xu, Lu; Sun, Yi; Politis, Constantinus; Egger, Jan

    2016-01-01

    In the orthognathic surgery, dental splints are important and necessary to help the surgeon reposition the maxilla or mandible. However, the traditional methods of manual design of dental splints are difficult and time-consuming. The research on computer-aided design software for dental splints is rarely reported. Our purpose is to develop a novel special software named EasySplint to design the dental splints conveniently and efficiently. The design can be divided into two steps, which are the generation of initial splint base and the Boolean operation between it and the maxilla-mandibular model. The initial splint base is formed by ruled surfaces reconstructed using the manually picked points. Then, a method to accomplish Boolean operation based on the distance filed of two meshes is proposed. The interference elimination can be conducted on the basis of marching cubes algorithm and Boolean operation. The accuracy of the dental splint can be guaranteed since the original mesh is utilized to form the result surface. Using EasySplint, the dental splints can be designed in about 10 minutes and saved as a stereo lithography (STL) file for 3D printing in clinical applications. Three phantom experiments were conducted and the efficiency of our method was demonstrated. PMID:27966601

  13. Development of a computer-aided design software for dental splint in orthognathic surgery.

    PubMed

    Chen, Xiaojun; Li, Xing; Xu, Lu; Sun, Yi; Politis, Constantinus; Egger, Jan

    2016-12-14

    In the orthognathic surgery, dental splints are important and necessary to help the surgeon reposition the maxilla or mandible. However, the traditional methods of manual design of dental splints are difficult and time-consuming. The research on computer-aided design software for dental splints is rarely reported. Our purpose is to develop a novel special software named EasySplint to design the dental splints conveniently and efficiently. The design can be divided into two steps, which are the generation of initial splint base and the Boolean operation between it and the maxilla-mandibular model. The initial splint base is formed by ruled surfaces reconstructed using the manually picked points. Then, a method to accomplish Boolean operation based on the distance filed of two meshes is proposed. The interference elimination can be conducted on the basis of marching cubes algorithm and Boolean operation. The accuracy of the dental splint can be guaranteed since the original mesh is utilized to form the result surface. Using EasySplint, the dental splints can be designed in about 10 minutes and saved as a stereo lithography (STL) file for 3D printing in clinical applications. Three phantom experiments were conducted and the efficiency of our method was demonstrated.

  14. Accuracy of five implant impression technique: effect of splinting materials and methods

    PubMed Central

    Cho, Sung-Bum

    2011-01-01

    PURPOSE The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure. PMID:22259700

  15. Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients.

    PubMed

    Thanathornwong, Bhornsawan; Suebnukarn, Siriwan

    2017-10-01

    The aim of this study was to develop a decision support model for the prediction of occlusal force from the size and color of articulating paper markings in bruxism patients. We used the information from the datasets of 30 bruxism patients in which digital measurements of the size and color of articulating paper markings (12-µm Hanel; Coltene/Whaledent GmbH, Langenau, Germany) on canine protected hard stabilization splints were measured in pixels (P) and in red (R), green (G), and blue (B) values using Adobe Photoshop software (Adobe Systems, San Jose, CA, USA). The occlusal force (F) was measured using T-Scan III (Tekscan Inc., South Boston, MA, USA). The multiple regression equation was applied to predict F from the P and RGB. Model evaluation was performed using the datasets from 10 new patients. The patient's occlusal force measured by T-Scan III was used as a 'gold standard' to compare with the occlusal force predicted by the multiple regression model. The results demonstrate that the correlation between the occlusal force and the pixels and RGB of the articulating paper markings was positive (F = 1.62×P + 0.07×R -0.08×G + 0.08×B + 4.74; R 2 = 0.34). There was a high degree of agreement between the occlusal force of the patient measured using T-Scan III and the occlusal force predicted by the model (kappa value = 0.82). The results obtained demonstrate that the multiple regression model can predict the occlusal force using the digital values for the size and color of the articulating paper markings in bruxism patients.

  16. Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients

    PubMed Central

    Thanathornwong, Bhornsawan

    2017-01-01

    Objectives The aim of this study was to develop a decision support model for the prediction of occlusal force from the size and color of articulating paper markings in bruxism patients. Methods We used the information from the datasets of 30 bruxism patients in which digital measurements of the size and color of articulating paper markings (12-µm Hanel; Coltene/Whaledent GmbH, Langenau, Germany) on canine protected hard stabilization splints were measured in pixels (P) and in red (R), green (G), and blue (B) values using Adobe Photoshop software (Adobe Systems, San Jose, CA, USA). The occlusal force (F) was measured using T-Scan III (Tekscan Inc., South Boston, MA, USA). The multiple regression equation was applied to predict F from the P and RGB. Model evaluation was performed using the datasets from 10 new patients. The patient's occlusal force measured by T-Scan III was used as a ‘gold standard’ to compare with the occlusal force predicted by the multiple regression model. Results The results demonstrate that the correlation between the occlusal force and the pixels and RGB of the articulating paper markings was positive (F = 1.62×P + 0.07×R –0.08×G + 0.08×B + 4.74; R2 = 0.34). There was a high degree of agreement between the occlusal force of the patient measured using T-Scan III and the occlusal force predicted by the model (kappa value = 0.82). Conclusions The results obtained demonstrate that the multiple regression model can predict the occlusal force using the digital values for the size and color of the articulating paper markings in bruxism patients. PMID:29181234

  17. Surgical Outcome of Intermittent Exotropia With Improvement in Control Grade Subsequent to Part-time Preoperative Occlusion Therapy.

    PubMed

    Bang, Seung Pil; Lee, Dong Cheol; Lee, Se Youp

    2018-01-01

    To evaluate the effect of improvement in the control grade of intermittent exotropia using part-time occlusion therapy on the final postoperative outcome. Control of intermittent exotropia was graded as good, fair, or poor in 89 consecutive patients with intermittent exotropia during their first visit. The patients were reevaluated after part-time preoperative occlusion therapy and divided into two groups (improvement and no improvement) according to whether they showed improvement in control grade. The surgical success rate was compared retrospectively between the two groups. The mean angle of deviation on the first visit was 27.61 ± 5.40 prism diopters (PD) at distance and 29.82 ± 5.28 PD at near. There were significant improvements in the angles of deviation for distance (26.17 ± 5.09 PD) and near (27.26 ± 5.56 PD) after part-time occlusion (both P < .001). The 49 patients who had a significantly improved control grade had a significantly better surgical success rate (77.6%) than the 40 patients who did not (50%; P = .007). Part-time occlusion therapy improves the control grade of intermittent exotropia, leading to a better likelihood of successful surgery and a reduction of the angles of deviation for distance and near. [J Pediatr Ophthalmol Strabismus. 2018;55(1):59-64.]. Copyright 2017, SLACK Incorporated.

  18. Sociocultural and psychological determinants in migrants for noncompliance with occlusion therapy for amblyopia.

    PubMed

    Tjiam, Angela M; Akcan, Hilal; Ziylan, Fatma; Vukovic, Elizabet; Loudon, Sjoukje E; Looman, Caspar W N; Passchier, Jan; Simonsz, Huibert J

    2011-12-01

    Compliance with occlusion therapy for amblyopia in children is low when their parents have a low level of education, speak Dutch poorly, or originate from another country. We determined how sociocultural and psychological determinants affect compliance. Included were amblyopic children between the ages of 3 and 6, living in low socio-economic status (SES) areas. Compliance with occlusion therapy was measured electronically. Their parents completed an oral questionnaire, based on the "Social Position & Use of Social Services by Migrants and Natives" questionnaire that included demographics and questions on issues like education, employment, religion and social contacts. Parental fluency in Dutch was rated on a five-point scale. Regression analysis was used to describe the relationship between the level of compliance and sociocultural and psychological determinants. Data from 45 children and their parents were analyzed. Mean electronically measured compliance was 56 ± 44 percent. Children whose parents had close contact with their neighbors or who were highly dependent on their family demonstrated low levels of compliance. Children of parents who were members of a club and who had positive conceptualizations of Dutch society showed high levels of compliance. Poor compliance was also associated with low income, depression, and when patching interfered with the child's outdoor activity. Religion was not associated with compliance. Poor compliance with occlusion therapy seems correlated with indicators of social cohesion. High social cohesion at micro level, i.e., family, neighbors and friends, and low social cohesion on macro level, i.e., Dutch society, are associated with noncompliance. However, such parents tend to speak Dutch poorly, so it is difficult to determine its actual cause.

  19. Shin splints. Diagnosis, management, prevention.

    PubMed

    Moore, M P

    1988-01-01

    Our knowledge of the etiology of shin splints is incomplete. Biomechanical abnormalities are likely to be major factors in predisposing certain persons to such injury. Also, training errors are major etiologic factors. Because shin splints result from mechanical overload of various elements of the musculoskeletal system of the leg that exceed their adaptive remodeling capacity, rest and recovery should be emphasized as an important aspect of sports training. Accurate and prompt diagnosis reduces the severity and duration of the injury. Management should consist of measures to reduce inflammation and pain and to identify possible biomechanical factors that may be correctable by strengthening and flexibility exercises or by the use of an orthotic device.

  20. Surface electromyographic patterns of masticatory, neck, and trunk muscles in temporomandibular joint dysfunction patients undergoing anterior repositioning splint therapy.

    PubMed

    Tecco, Simona; Tetè, Stefano; D'Attilio, Michele; Perillo, Letizia; Festa, Felice

    2008-12-01

    The aim of this study was to investigate the surface electromyographic (sEMG) activity of neck, trunk, and masticatory muscles in subjects with temporomandibular joint (TMJ) internal derangement treated with anterior mandibular repositioning splints. sEMG activities of the muscles in 34 adult subjects (22 females and 12 males; mean age 30.4 years) with TMJ internal derangement were compared with a control group of 34 untreated adults (20 females and 14 males; mean age 31.8 years). sEMG activities of seven muscles (anterior and posterior temporalis, masseter, posterior cervicals, sternocleidomastoid, and upper and lower trapezius) were studied bilaterally, with the mandible in the rest position and during maximal voluntary clenching (MVC), at the beginning of therapy (T0) and after 10 weeks of treatment (T1). Paired and Student's t-tests were undertaken to determine differences between the T0 and T1 data and in sEMG activity between the study and control groups. At T0, paired masseter, sternocleidomastoid, and cervical muscles, in addition to the left anterior temporal and right lower trapezius, showed significantly greater sEMG activity (P = 0.0001; P = 0.0001; for left cervical, P = 0.03; for right cervical, P = 0.0001; P = 0.006 and P = 0.007 muscles, respectively) compared with the control group. This decreased over the remaining study period, such that after treatment, sEMG activity revealed no statistically significant difference when compared with the control group. During MVC at T0, paired masseter and anterior and posterior temporalis muscles showed significantly lower sEMG activity (P = 0.03; P = 0.005 and P = 0.04, respectively) compared with the control group. In contrast, at T1 sEMG activity significantly increased (P = 0.02; P = 0.004 and P = 0.04, respectively), but no difference was observed in relation to the control group. Splint therapy in subjects with internal disk derangement seems to affect sEMG activity of the masticatory, neck, and trunk

  1. Operating Room Time Savings with the Use of Splint Packs: A Randomized Controlled Trial

    PubMed Central

    Gonzalez, Tyler A.; Bluman, Eric M.; Palms, David; Smith, Jeremy T.; Chiodo, Christopher P.

    2016-01-01

    Background: The most expensive variable in the operating room (OR) is time. Lean Process Management is being used in the medical field to improve efficiency in the OR. Streamlining individual processes within the OR is crucial to a comprehensive time saving and cost-cutting health care strategy. At our institution, one hour of OR time costs approximately $500, exclusive of supply and personnel costs. Commercially prepared splint packs (SP) contain all components necessary for plaster-of-Paris short-leg splint application and have the potential to decrease splint application time and overall costs by making it a more lean process. We conducted a randomized controlled trial comparing OR time savings between SP use and bulk supply (BS) splint application. Methods: Fifty consecutive adult operative patients on whom post-operative short-leg splint immobilization was indicated were randomized to either a control group using BS or an experimental group using SP. One orthopaedic surgeon (EMB) prepared and applied all of the splints in a standardized fashion. Retrieval time, preparation time, splint application time, and total splinting time for both groups were measured and statistically analyzed. Results: The retrieval time, preparation time and total splinting time were significantly less (p<0.001) in the SP group compared with the BS group. There was no significant difference in application time between the SP group and BS group. Conclusion: The use of SP made the process of splinting more lean. This has resulted in an average of 2 minutes 52 seconds saved in total splinting time compared to BS, making it an effective cost-cutting and time saving technique. For high volume ORs, use of splint packs may contribute to substantial time and cost savings without impacting patient safety. PMID:26894212

  2. Compliance with occlusion therapy for childhood amblyopia.

    PubMed

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2013-09-17

    Explore compliance with occlusion treatment of amblyopia in the Monitored and Randomized Occlusion Treatment of Amblyopia Studies (MOTAS and ROTAS), using objective monitoring. Both studies had a three-phase protocol: initial assessment, refractive adaptation, and occlusion. In the occlusion phase, participants were instructed to dose for 6 hours/day (MOTAS) or randomized to 6 or 12 hour/day (ROTAS). Dose was monitored continuously using an occlusion dose monitor (ODM). One hundred and fifty-two patients (71 male, 81 female; 122 Caucasian, 30 non-Caucasian) of mean ± SD age 68 ± 18 months participated. Amblyopia was defined as an interocular acuity difference of at least 0.1 logMAR and was associated with anisometropia in 50, strabismus in 44, and both (mixed) in 58. Median duration of occlusion was 99 days (interquartile range 72 days). Mean compliance was 44%, mean proportion of days with no patch worn was 42%. Compliance was lower (39%) on weekends compared with weekdays (46%, P = 0.04), as was the likelihood of dosing at all (52% vs. 60%, P = 0.028). Compliance was lower when attendance was less frequent (P < 0.001) and with prolonged treatment duration (P < 0.001). Age, sex, amblyopia type, and severity were not associated with compliance. Mixture modeling suggested three subpopulations of patch day doses: less than 30 minutes; doses that achieve 30% to 80% compliance; and doses that achieve around 100% compliance. This study shows that compliance with patching treatment averages less than 50% and is influenced by several factors. A greater understanding of these influences should improve treatment outcome. (ClinicalTrials.gov number, NCT00274664).

  3. Professional musicians with craniomandibular dysfunctions treated with oral splints.

    PubMed

    Steinmetz, Anke; Ridder, Paul H; Methfessel, Götz; Muche, Burkhard

    2009-10-01

    Craniomandibular dysfunction (CMD) symptoms occur frequently in violin/viola and wind players and can be associated with pain in the neck, shoulders and arm. In the current study, the effect of oral splint treatment of CMD on reducing pain and symptoms especially in these areas was investigated. Thirty (30) musicians undergoing CMD treatment with oral splints participated in this study. They completed a questionnaire that addressed CMD symptoms, localization of pain, and subjective changes in symptoms. Pain in the shoulder and/or upper extremity was the most frequent symptom reported by 83% of subjects, followed by neck pain (80%) and pain in the teeth/TMJ regions (63%). Treatment with oral splints contributed to a significant decrease in neck pain in 91%, teeth/TMJ pain in 83%, and shoulder and upper extremity pain in 76% of the musicians. Eighty percent (80%) of the patients reported improvement of their predominant symptoms. CMD can be a potential cause for pain in the neck, shoulders, and upper extremities of musicians. It is paramount that musicians with musculoskeletal problems be examined for CMD symptoms. Treatment with oral splints seems to be valuable. Further prospective, randomized controlled studies are necessary to confirm efficacy of oral splint treatment in CMD-associated pain and problems in the neck, shoulder, and the upper extremities in musicians.

  4. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.

    PubMed

    Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq

    2014-08-01

    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.

  5. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

    PubMed

    Kim, Yongsik; Oh, Tae-Ju; Misch, Carl E; Wang, Hom-Lay

    2005-02-01

    Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

  6. Comparison between an Acrylic Splint Herbst and an Acrylic Splint Miniscrew-Herbst for Mandibular Incisors Proclination Control

    PubMed Central

    Manni, Antonio; Pasini, Marco; Nuzzo, Claudio; Grassi, Felice Roberto

    2014-01-01

    Aim. The aim of this study is to compare dental and skeletal effects produced by an acrylic splint Herbst with and without skeletal anchorage for correction of dental class II malocclusion. Methods. The test group was formed by 14 patients that were treated with an acrylic splint miniscrew-Herbst; miniscrews were placed between mandibular second premolars and first molars; controls also consisted of 14 subjects that were treated with an acrylic splint Herbst and no miniscrews. Cephalometric measurements before and after Herbst treatment were compared. The value of α for significance was set at 0.05. Results. All subjects from both groups were successfully treated to a bilateral Class I relationship; mean treatment time was 8,1 months in the test group and 7.8 in the controls. Several variables did not have a statistical significant difference between the two groups. Some of the variables, instead, presented a significant difference such as incisor flaring, mandibular bone base position, and skeletal discrepancy. Conclusions. This study showed that the Herbst appliance associated to miniscrews allowed a better control of the incisor flaring with a greater mandibular skeletal effect. PMID:24963293

  7. Part-time occlusion therapy for anisometropic amblyopia detected in children eight years of age and older.

    PubMed

    Lee, Young Rok; Lee, Ju Youn

    2006-09-01

    To determine the outcome of part-time occlusion therapy in children with anisometropic amblyopia detected after they were 8 years of age. We analyzed 29 eyes with anisometropic amblyopia in children 8 years of age and older. The mean age was 8.79 +/- 0.98 (range 8-12) years old. The subjects whose best-corrected visual acuity (BCVA) did not improve by two lines or better within 2 weeks of wearing glasses full-time were prescribed occlusion therapy for 6 hours a day outside of school hours, along with the instruction to wear glasses full-time. Subjects who complied with occlusion for more than 3 hours a day were considered to comply well. The major component of the anisometropia was hyperopia in 51.7% of the subjects, and hyperopia plus astigmatism was found in 24.1%. The mean pretreatment BCVA score was 0.51 0.23 (LogMAR). Compliance was 89.66%. The mean posttreatment BCVA was 0.03 +/- 0.01 (LogMAR), and the success rate, based on a posttreatment BCVA of 0.1 (LogMAR) and better, was 96.43%. It took an average of 4.79 +/- 3.35 months to reach the desired posttreatment BCVA. The mean posttreatment stereopsis was 79.78 +/- 37.61 seconds of arc. The recurrence rate was 8%. The visual improvement was related to the degree of compliance (p = 0.000). The time taken to reach the posttreatment BCVA was shorter in subjects with a better pretreatment BCVA (p = 0.019), but it did not relate to the compliance (p = 0.366). The most common component of anisometropia detected after 8 years of age was hyperopia. The part-time occlusion therapy, which had been carried out after school hours, was successful in most cases.

  8. Part-Time Occlusion Therapy for Anisometropic Amblyopia Detected in Children Eight Years of Age and Older

    PubMed Central

    Lee, Young Rok

    2006-01-01

    Purpose To determine the outcome of part-time occlusion therapy in children with anisometropic amblyopia detected after they were 8 years of age. Methods We analyzed 29 eyes with anisometropic amblyopia in children 8 years of age and older. The mean age was 8.79±0.98 (range 8~12) years old. The subjects whose best-corrected visual acuity (BCVA) did not improve by two lines or better within 2 weeks of wearing glasses full-time were prescribed occlusion therapy for 6 hours a day outside of school hours, along with the instruction to wear glasses full-time. Subjects who complied with occlusion for more than 3 hours a day were considered to comply well. Results The major component of the anisometropia was hyperopia in 51.7% of the subjects, and hyperopia plus astigmatism was found in 24.1%. The mean pretreatment BCVA score was 0.51±0.23 (LogMAR). Compliance was 89.66%. The mean posttreatment BCVA was 0.03±0.01 (LogMAR), and the success rate, based on a posttreatment BCVA of 0.1 (LogMAR) and better, was 96.43%. It took an average of 4.79±3.35 months to reach the desired posttreatment BCVA. The mean posttreatment stereopsis was 79.78±37.61 seconds of arc. The recurrence rate was 8%. The visual improvement was related to the degree of compliance (p=0.000). The time taken to reach the posttreatment BCVA was shorter in subjects with a better pretreatment BCVA (p=0.019), but it did not relate to the compliance (p=0.366). Conclusions The most common component of anisometropia detected after 8 years of age was hyperopia. The part-time occlusion therapy, which had been carried out after school hours, was successful in most cases. PMID:17004632

  9. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure

    PubMed Central

    2014-01-01

    Background The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee’s satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. Methods The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. Results The subject’s dynamic pressure on the socket that’s applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. Conclusion The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics. PMID:25085005

  10. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    PubMed

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  11. Accuracy of virtual surgical planning of orthognathic surgery with aid of CAD/CAM fabricated surgical splint-A novel 3D analyzing algorithm.

    PubMed

    Chin, Shih-Jan; Wilde, Frank; Neuhaus, Michael; Schramm, Alexander; Gellrich, Nils-Claudius; Rana, Majeed

    2017-12-01

    The benefit of computer-assisted planning in orthognathic surgery has been extensively documented over the last decade. This study aims to evaluate the accuracy of a virtual orthognathic surgical plan by a novel three dimensional (3D) analysis method. Ten patients who required orthognathic surgery were included in this study. A virtual surgical plan was achieved by the combination of a 3D skull model acquired from computed tomography (CT) and surface scanning of the upper and lower dental arch respectively and final occlusal position. Osteotomies and movement of maxilla and mandible were simulated by Dolphin Imaging 11.8 Premium ® (Dolphin Imaging and Management Solutions, Chatsworth, CA). The surgical plan was transferred to surgical splints fabricated by means of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM). Differences of three dimensional measurements between the virtual surgical plan and postoperative results were evaluated. The results from all parameters showed that the virtual surgical plans were successfully transferred by the assistance of CAD/CAM fabricated surgical splint. Wilcoxon's signed rank test showed that no statistically significant deviation between surgical plan and post-operational result could be detected. However, deviation of angle U1 axis-HP and distance of A-CP could not fulfill the clinical success criteria. Virtual surgical planning and CAD/CAM fabricated surgical splint are proven to facilitate treatment planning and offer an accurate surgical result in orthognathic surgery. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Removing intranasal splints after septal surgery.

    PubMed

    Aksoy, Elif; Serin, Gediz Murat; Polat, Senol; Kaytaz, Asm

    2011-05-01

    The aim of this retrospective chart review of the patients who had septal surgery with or without turbinate surgery was to compare the postoperative complication rates according to the time of intranasal-splint (INS) removal. The data of 137 patients who underwent septal surgery with or without turbinate surgery at 2 different hospitals of Acıbadem Health Care Group between January 2007 and March 2009 were retrospectively evaluated. The patients who had these risk factors were eliminated, and 96 patients were included in this study. The patients were divided into 2 groups according to splint-removal time. The first group comprises patients whose nasal splints were removed in 24 hours after surgery, and the second group comprises patients whose splints were removed 5 days after the surgery. Any bleeding, septal hematoma, and synechia after pack removal were recorded. Analysis of the rate of complications was done with the χ test. Sixty-five male and 31 female patients with a mean age of 32.4 years (range, 18-57 years) were included in the study groups. Septal surgeries were performed in association with turbinate surgery in all 96 patients. These patients were divided into 2 groups. In the first group (n = 50), INSs were removed in 24 hours after surgery. In the second group (n = 46), INSs were removed 5 days after surgery. Bleeding within the first postoperative week was not recorded in both groups. Late bleeding was recorded in 2% (n = 1) of group 1 and in 2.17% (n = 1) in group 2. Septal hematoma and synechia were not recorded in none of the groups. The results were not statistically significant (P = 1). The routine use of INSs after septoplasty and removing them 24 hours after septoplasty are sufficient to avoid postoperative complications, and it minimizes postoperative discomfort.

  13. Removable splint with locking attachments for maxillary distraction osteogenesis with the RED system.

    PubMed

    Suzuki, E Y; Suzuki, B

    2007-12-01

    The external traction hooks of the intraoral splint used to control traction forces applied to the maxilla with the rigid external distraction system represent a major barrier to surgical procedures. The purpose of this article is to introduce a removable intraoral splint with locking attachments that can be placed post-surgically immediately before distraction, facilitating surgery and consequently reducing the operative time. Fifteen cleft lip and palate patients underwent maxillary distraction osteogenesis using a rigid external distraction device in combination with the proposed removable splint that was fixed onto the maxillary teeth to provide anchorage. Initial records showed severe maxillary hypoplasia and negative overjet. The removable splint was fabricated using 1.5-mm diameter stainless-steel rigid orthodontic wires soldered to the locking attachments (Y&B Products LP, Chiang Mai, Thailand), making possible its placement post-surgically. Stable splint fixation was achieved prior to the distraction procedure and the desired treatment goals were reached. No complications inserting or removing the splint post-surgically, including pain or discomfort, were observed. The use of the removable splint with locking attachments has proved to be a highly effective fixation approach to manage the severely hypoplastic maxilla, eliminating lip constraints resulting from scarring, and allowing for easier, more deliberate and careful dissection.

  14. Polishability and wear resistance of splint material for oral appliances produced with conventional, subtractive, and additive manufacturing.

    PubMed

    Huettig, Fabian; Kustermann, Achim; Kuscu, Ebru; Geis-Gerstorfer, Jürgen; Spintzyk, Sebastian

    2017-11-01

    Occlusal splints to treat bruxism are commonly made from polymethylmethacrylate (PMMA) in a manual workflow (powder-liquid technique). Today digitalization allows a machine-based manufacturing in subtractive (milling) and additive (printing) means using industrial-made PMMA or comparable resins. An in-vitro study should assess the surface finish and screen the wear resistance of conventional and industrial materials. Therefore, a total of 30 specimens made from conventionally PMMA (group C; powder-liquid, Palapress), polycarbonate ingots (group S; innoBlanc splint plus), and light-curing resin (group A; VarseoWax splint) were polished to examine the surface roughness (Ra) by profilometry and further analyzed by SEM. The specimens were loaded with a steatite ball moving 5000 times along 1cm with 5N of surface pressure under constant wetting (artificial saliva). The total height of profile (Pt) was calculated by further profilometry of the specimens. All specimen showed initially comparable Ra values ranging between 0.06 and 0.05µm (SD = 0.01) after polishing. SEM investigations revealed no visual cues for scratches or irregularities in any group. After abrasion test, the comparison of the wear depths, revealed mean Pt values of 111.4µm (SD = 18.5) in C, 85.7µm (SD = 21.5) in S, and 99.1µm (SD = 21.5) in A, whereas the mean of S was statistically different from C (p = 0.025). No signs of abrasion were found on the steatite balls. All materials showed comparable polished surfaces and a similar scale of wear. It remains questionable if the detected statistical differences are of clinical relevance, but indicates the need for tests of novel materials, especially in additive manufacturing. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The biomechanical analysis of three-dimensional distal radius fracture model with different fixed splints.

    PubMed

    Hua, Zhen; Wang, Jian-Wei; Lu, Zhen-Fei; Ma, Jian-Wei; Yin, Heng

    2018-01-01

    The distal radius fracture is one of the common clinical fractures. At present, there are no reports regarding application of the finite element method in studying the mechanism of Colles fracture and the biomechanical behavior when using splint fixation. To explore the mechanism of Colles fracture and the biomechanical behavior when using different fixed splints. Based on the CT scanning images of forearm for a young female volunteer, by using model construction technology combined with RPOE and ANSYS software, a 3-D distal radius fracture forearm finite element model with a real shape and bioactive materials is built. The material tests are performed to obtain the mechanical properties of the paper-based splint, the willow splint and the anatomical splint. The numerical results are compared with the experimental results to verify the correctness of the presented model. Based on the verified model, the stress distribution of different tissues are analyzed. Finally, the clinical tests are performed to observe and verify that the anatomical splint is the best fit for human body. Using the three kinds of splints, the transferred bone stress focus on the distal radius and ulna, which is helpful to maintain the stability of fracture. Also the stress is accumulated in the distal radius which may be attributed to flexion position. Such stress distribution may be helpful to maintain the ulnar declination. By comparing the simulation results with the experimental observations, the anatomical splint has the best fitting to the limb, which can effectively avoid the local compression. The anatomical splint is the most effective for fixing and curing the fracture. The presented model can provide theoretical basis and technical guide for further investigating mechanism of distal radius fracture and clinical application of anatomical splint.

  16. Backscattering from dental restorations and splint materials during therapeutic radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farman, A.G.; Sharma, S.; George, D.I.

    1985-08-01

    Models were constructed to simulate as closely as possible the human oral cavity. Radiation absorbed doses were determined for controls and various test situations involving the presence of dental restorative and splint materials during cobalt-60 irradiation of the models. Adjacent gold full crowns and adjacent solid dental silver amalgam cores both increased the dose to the interproximal gingivae by 20%. Use of orthodontic full bands for splinting the jaws increased the dose to the buccal tissues by an average of 10%. Augmentation of dose through backscatter radiation was determined to be only slight for intracoronal amalgam fillings and stainless steelmore » or plastic bracket splints.« less

  17. The effect of splinting implant-supported restorations on stress distribution of different crown-implant ratios and crown height spaces.

    PubMed

    Nissan, Joseph; Gross, Ora; Ghelfan, Oded; Priel, Ilan; Gross, Martin; Chaushu, Gavriel

    2011-12-01

    To assess whether splinting can counterbalance the detrimental effects of varying the crown-to-implant (C/I) ratio and crown height space (CHS) by decreasing nonaxial overload stresses. Three implants were inserted into a photoelastic block model. Two strain gauges were cemented onto the neck of each implant on the buccal and lingual aspects and provided a simultaneous direct reading of strain. Four groups of splinted cement-retained restorations with C/I ratios of 1:1, 1:1.5, 1:1.75, and 1:2 were used. CHSs were 10, 15, 17.5, and 20 mm, respectively. Fifteen static loadings were carried out simultaneously with 20-kg weights via a custom-built loading apparatus at 30° to the vertical axis. Occlusal force application at 30° showed a statistically significant increase in both buccal (1,911.65 ± 110 vs 3,252.06 ± 150) and palatal (35.58 ± 7 vs 286.85 ± 15) microstrain values as the C/I ratio increased from 1:1 to 1:1.5 (P < .001). Force application at 30° in cases with C/I ratios of 1:1.75 and 1:2 resulted in fracture of the abutment screw followed by dislodgement of the crowns. Failures were noted at a CHS of 15 mm or greater. In this biomechanical mode, splinting does not prevent prosthetic failure when the CHS is 15 mm or greater. Vertical bone augmentation is highly recommended in cases with a CHS of 15 mm or greater. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. In Vitro Implant Impression Accuracy Using a New Photopolymerizing SDR Splinting Material.

    PubMed

    Di Fiore, Adolfo; Meneghello, Roberto; Savio, Gianpaolo; Sivolella, Stefano; Katsoulis, Joannis; Stellini, Edoardo

    2015-10-01

    The study aims to evaluate three-dimensionally (3D) the accuracy of implant impressions using a new resin splinting material, "Smart Dentin Replacement" (SDR). A titanium model of an edentulous mandible with six implant analogues was used as a master model and its dimensions measured with a coordinate measuring machine. Before the total 60 impressions were taken (open tray, screw-retained abutments, vinyl polysiloxane), they were divided in four groups: A (test): copings pick-up splinted with dental floss and fotopolymerizing SDR; B (test): see A, additionally sectioned and splinted again with SDR; C (control): copings pick-up splinted with dental floss and autopolymerizing Duralay® (Reliance Dental Mfg. Co., Alsip, IL, USA) acrylic resin; and D (control): see C, additionally sectioned and splinted again with Duralay. The impressions were measured directly with an optomechanical coordinate measuring machine and analyzed with a computer-aided design (CAD) geometric modeling software. The Wilcoxon matched-pair signed-rank test was used to compare groups. While there was no difference (p = .430) between the mean 3D deviations of the test groups A (17.5 μm) and B (17.4 μm), they both showed statistically significant differences (p < .003) compared with both control groups (C 25.0 μm, D 19.1 μm). Conventional impression techniques for edentulous jaws with multiple implants are highly accurate using the new fotopolymerizing splinting material SDR. Sectioning and rejoining of the SDR splinting had no impact on the impression accuracy. © 2015 Wiley Periodicals, Inc.

  19. Rapid customization system for 3D-printed splint using programmable modeling technique - a practical approach.

    PubMed

    Li, Jianyou; Tanaka, Hiroya

    2018-01-01

    Traditional splinting processes are skill dependent and irreversible, and patient satisfaction levels during rehabilitation are invariably lowered by the heavy structure and poor ventilation of splints. To overcome this drawback, use of the 3D-printing technology has been proposed in recent years, and there has been an increase in public awareness. However, application of 3D-printing technologies is limited by the low CAD proficiency of clinicians as well as unforeseen scan flaws within anatomic models.A programmable modeling tool has been employed to develop a semi-automatic design system for generating a printable splint model. The modeling process was divided into five stages, and detailed steps involved in construction of the proposed system as well as automatic thickness calculation, the lattice structure, and assembly method have been thoroughly described. The proposed approach allows clinicians to verify the state of the splint model at every stage, thereby facilitating adjustment of input content and/or other parameters to help solve possible modeling issues. A finite element analysis simulation was performed to evaluate the structural strength of generated models. A fit investigation was applied on fabricated splints and volunteers to assess the wearing experience. Manual modeling steps involved in complex splint designs have been programed into the proposed automatic system. Clinicians define the splinting region by drawing two curves, thereby obtaining the final model within minutes. The proposed system is capable of automatically patching up minor flaws within the limb model as well as calculating the thickness and lattice density of various splints. Large splints could be divided into three parts for simultaneous multiple printing. This study highlights the advantages, limitations, and possible strategies concerning application of programmable modeling tools in clinical processes, thereby aiding clinicians with lower CAD proficiencies to become adept

  20. [Evaluation of the clinical results of non-surgical treatment for pediatric sagittal fracture of mandibular condyle].

    PubMed

    Liu, Chang-kui; Tan, Xin-ying; Xu, Juan; Liu, Hua-wei; Liu, San-xia; Hu, Min

    2013-11-01

    To investigate the clinical results of occlusal splint in the treatment of sagittal fracture of mandibular condyle (SFMC) in children. Thirty-nine patients (48 condyles)aged 3-8 years with sagittal fracture of mandibular condyle were included in this study. All the patients were treated by occlusal splint.Slight open occlusion was maintained by occlusal splint for 3-6 months. Clinical and radiological examination was performed six mouths and every year after treatment. Good mandibular function was observed in 39 patients. Maximal mouth opening over 35 mm was achieved at 6 months. But 11 of the 39 patients presented with deviation on mouth opening at 6 months. The radiology showed an complete remodeling in 32 condyles (28 patients) and partial remodeling in 16 condyles (11 patients). Poor remodelling was not observed in any patients. Good clinical results can be obtained by using occlusal splint in the treatment of pediatric sagittal fracture of mandibular condyle.

  1. Predictors of Good Outcome After Endovascular Therapy for Vertebrobasilar Occlusion Stroke.

    PubMed

    Bouslama, Mehdi; Haussen, Diogo C; Aghaebrahim, Amin; Grossberg, Jonathan A; Walker, Gregory; Rangaraju, Srikant; Horev, Anat; Frankel, Michael R; Nogueira, Raul G; Jovin, Tudor G; Jadhav, Ashutosh P

    2017-12-01

    Endovascular therapy is increasingly used in acute ischemic stroke treatment and is now considered the gold standard approach for selected patient populations. Prior studies have demonstrated that eventual patient outcomes depend on both patient-specific factors and procedural considerations. However, these factors remain unclear for acute basilar artery occlusion stroke. We sought to determine prognostic factors of good outcome in acute posterior circulation large vessel occlusion strokes treated with endovascular therapy. We reviewed our prospectively collected endovascular databases at 2 US tertiary care academic institutions for patients with acute posterior circulation strokes from September 2005 to September 2015 who had 3-month modified Rankin Scale documented. Baseline characteristics, procedural data, and outcomes were evaluated. A good outcome was defined as a 90-day modified Rankin Scale score of 0 to 2. The association between clinical and procedural parameters and functional outcome was assessed. A total of 214 patients qualified for the study. Smoking status, creatinine levels, baseline National Institutes of Health Stroke Scale score, anesthesia modality (conscious sedation versus general anesthesia), procedural length, and reperfusion status were significantly associated with good outcomes in the univariate analysis. Multivariate logistic regression indicated that only smoking (odds ratio=2.61; 95% confidence interval, 1.23-5.56; P =0.013), low baseline National Institutes of Health Stroke Scale score (odds ratio=1.09; 95% confidence interval, 1.04-1.13; P <0.0001), and successful reperfusion status (odds ratio=10.80; 95% confidence interval, 1.36-85.96; P =0.025) were associated with good outcome. In our retrospective case series, only smoking, low baseline National Institutes of Health Stroke Scale score, and successful reperfusion status were associated with good outcome in patients with posterior circulation stroke treated with endovascular

  2. Intervention Therapy for Portal Vein Stenosis/Occlusion After Pediatric Liver Transplantation.

    PubMed

    Gao, Haijun; Wang, Hao; Chen, Guang; Yi, Zhengjia

    2017-04-18

    BACKGROUND The aim of this study was to investigate the outcomes and stent implantation timing of portal vein stenosis intervention after pediatric liver transplantation (pLT). MATERIAL AND METHODS The clinical data of 30 children with post-liver transplantation portal vein stenosis/occlusion (PVS/O) between Jan 2008 and Jun 2015 were retrospectively analyzed. The successfully re-opened cases used balloon angioplasty or stent implantation. SPSS13.0 software was used for statistical analysis and paired t test of the pressure gradient at both ends of the stenosis, diameter and flow rate within the stenosis, platelet count, and albumin in the PVS children before and after balloon angioplasty, with p<0.05 considered as statistically significant. Among the 30 patients, 6 received a stent implant in their first treatment, 22 received balloon angioplasty in their first treatment, and in 2 the re-opening could not be achieved. RESULTS The diameter of the stenotic segment, portal vein velocity, pressure gradient at both ends of the stenosis, and platelet count in these children with portal vein stenosis/occlusion (PVS/O) showed statistically significant differences when comparing values before and after intervention (p<0.05), but albumin showed no statistically significant difference (p>0.05). CONCLUSIONS Intervention therapy for portal vein stenosis after pediatric liver transplantation (pLT-PVS) is a safe and effective treatment, and patients with portal vein torsion, intimal tearing, or long portal vein segment occlusion should undergo stent implantation.

  3. 3D motion analysis of the wrist splint effect to wrist joint movement.

    PubMed

    Shin, Joong-Il; Park, Soo-Hee

    2017-06-01

    [Purpose] This study aimed to investigate the degree of straightness of the wrist joint, depending on the use of a wrist splint while opening a bottle cap. Its results may provide data for later studies on preventing accidents at workplaces and improving efficiency. [Subjects and Methods] Thirty Male and Female in their twenties who did not have hand-related diseases, fractures, or history that included neurological impairments associated with the hand were selected as subjects of the study. Wrist splints were made to fit the hand and lower arm of each subject. Evaluation assignments were carried out without and with the splints after 10 minutes of rest. To analyze the wrist movement in opening the bottle cap, a three-dimensional movement analyzing system by Zebris was used. [Results] Wrist angle decreased while opening caps of four different diameters while wearing splints, but not when splints were not worn. This means that wearing a splint may aid weakened wrist muscles. [Conclusion] Future studies should be conducted among subjects with damaged wrist muscles and evaluate the subjects in actual workplaces to obtain more objective and more valid data.

  4. 3D motion analysis of the wrist splint effect to wrist joint movement

    PubMed Central

    Shin, Joong-il; Park, Soo-hee

    2017-01-01

    [Purpose] This study aimed to investigate the degree of straightness of the wrist joint, depending on the use of a wrist splint while opening a bottle cap. Its results may provide data for later studies on preventing accidents at workplaces and improving efficiency. [Subjects and Methods] Thirty Male and Female in their twenties who did not have hand-related diseases, fractures, or history that included neurological impairments associated with the hand were selected as subjects of the study. Wrist splints were made to fit the hand and lower arm of each subject. Evaluation assignments were carried out without and with the splints after 10 minutes of rest. To analyze the wrist movement in opening the bottle cap, a three-dimensional movement analyzing system by Zebris was used. [Results] Wrist angle decreased while opening caps of four different diameters while wearing splints, but not when splints were not worn. This means that wearing a splint may aid weakened wrist muscles. [Conclusion] Future studies should be conducted among subjects with damaged wrist muscles and evaluate the subjects in actual workplaces to obtain more objective and more valid data. PMID:28626332

  5. Postsurgical Orthodontic Treatment Planning: a Case Report with 20 Years Follow-up.

    PubMed

    Farronato, Giampietro; Garagiola, Umberto; Carletti, Vera; Cressoni, Paolo; Mortellaro, Carmen

    2011-01-01

    Traditionally, maxillofacial deformities are corrected surgically after an initial orthodontic treatment phase. However in, this article, the authors emphasize the postsurgical therapeutic protocol which is extremely important for determining the final and permanent retention of the corrected occlusion. A 55 year old female with severe skeletal Class II malocclusion is presented. Combined surgical and orthodontic correction of the malocclusion was used. : The step-by-step procedure the authors followed for the postsurgical therapy is described. The goals of the postoperative therapy were to restore and rehabilitate neuromuscular function, obtain occlusal stabilization, grind teeth selectively, and final occlusion retention. The importance of a surgical occlusal splint for rehabilitating stomatognathic neuromuscular function postoperatively was demonstrated. Furthermore, the orthodontic-prosthodontic treatment ensured occlusion stability after the surgical correction. The long-term results confirmed the efficacy of the treatment protocol presented here from both functional and aesthetical perspectives. Postsurgical orthodontic treatment is an important step in the surgical and orthodontic therapy of maxillofacial deformities.

  6. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  7. Needle aponeurotomy for Dupuytren contracture: Effectiveness of postoperative night extension splinting.

    PubMed

    Tam, Louisa; Chung, Yin-Yin

    2016-01-01

    Night extension splinting has been used to treat patients with Dupuytren contracture to improve active range of motion (AROM) of the hand. A published case study demonstrated the benefit of splinting following needle aponeurotomy; however, no larger studies have evaluated the impact of postoperative splinting. To compare the impact of night extension splinting on AROM, specifically extension, following needle aponeurotomy for Dupuytren contracture. A retrospective chart review was conducted in which the charts of 53 patients who underwent needle aponeurotomy for Dupuytren contracture between 2009 and 2013 were reviewed. The control group consisted of patients who underwent needle aponeurotomy only, whereas the treatment group was also referred for fabrication of custom night extension splints after surgery. Comparisons in pre- and postoperative AROM measurements for the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints were made between both groups of patients. The degrees of change in AROM for each joint were categorized in terms of levels of change: mild (0° to 29°); moderate (30° to 60°); and significant (≥61°). All patients exhibited increased AROM after surgery for both MCP and PIP joints. Both groups had a greater increase in AROM in the MCP joint. Twelve joints from the control group had moderate changes and two from the treatment group had significant changes. When both groups were compared, the levels of change of AROM between both groups did not vary significantly. Night extension splinting following needle aponeurotomy may not improve AROM of the MCP or PIP joints.

  8. Retrospective study of combined splinting restorations in the aesthetic zone of periodontal patients

    PubMed Central

    Liu, X.; Zhang, Y.; Zhou, Z.; Ma, S.

    2016-01-01

    Aims This retrospective study evaluated the clinical performance of combining a fiber-reinforced, composite-resin (FRC) bonded splint; bridge; fiber post; and/or resin veneer for the restoration of periodontally-involved anterior teeth. Methods Sixty-three patients with periodontally-involved anterior teeth each received one of the following splinting restorations: FRC-bonded splint-bridges (SB), a combination of an FRC-bonded splint and resin veneer (SV), or FRC-bonded splints (S). Six patients with healthy periodontal teeth received orthodontic retainers with FRC-bonded splints (OS) as a control. Modified USPHS criteria were used to evaluate the effects of rehabilitation, and the periodontal pocket depth (PPD) and clinical attachment level (CAL) of the natural teeth were measured. Results All restorations resulted in good aesthetic outcomes. SV, S in combination with fiber posts and OS all resulted in 100% acceptable ratings for each category that was directly evaluated at each follow-up. The mean PPD was 3.5 ± 1.0 mm at baseline, decreased to 3.3 ± 1.0 mm after one year (p <0.05), and subsequently increased to 3.5±1.0 mm again after four years (p >0.05). These changes were similar to those in the mean CAL. Conclusion A combination of a FRC-bonded splint, bridge, fiber post and/or resin veneer for minimally invasive prosthodontic treatment in the aesthetic zone is a good choice for periodontal patients. PMID:26964599

  9. External airway splint to treat tracheomalacia following laryngotracheal reconstruction.

    PubMed

    Hsueh, Wayne D; Smith, Lee P

    2017-03-01

    This observation reports the use of an external airway splint to treat tracheomalacia in a pediatric patient. The patient underwent a double stage laryngotracheal reconstruction however was unable to be decannulated due to severe tracheomalacia. Our purpose is to further support the use of external splinting in the treatment of tracheomalacia in a unique case involving isolated nighttime airway obstruction following laryngotracheal reconstruction. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Continuing to work with a sterile thumb splint: A case report.

    PubMed

    Roner, S; Fürnstahl, P; Schweizer, A; Wieser, K

    2018-05-17

    Nonoperative treatment of an injured ulnar collateral ligament of the thumb metacarpophalangeal (MCP) joint (skier's thumb without a Stener lesion) is managed by immobilization. A splint is applied on the radial side with the thumb in slight flexion to immobilize the MCP joint and allow motion in the interphalangeal joint. Thermoplastic splints are mainly used for daily activities with the advantage of custom fabrication for optimal comfort. To immobilize the thumb during surgical procedures performed by an orthopedic surgeon, splints made of sterilizable materials are needed but not yet available to our knowledge. We present the case of a 36-year-old orthopedic surgeon diagnosed with skier's thumb, and the development and application of a reusable, patient-specific (i.e., the orthopedic surgeon) splint to immobilize the thumb MCP joint in a sterile environment so the surgeon could continue working. Copyright © 2018 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  11. Evaluating Stiffness of Fibreglass and Thermoplastic Splint Materials and Inter-fragmentary Motion in a Canine Tibial Fracture Model.

    PubMed

    Wagoner, Amanda L; Allen, Matthew J; Zindl, Claudia; Litsky, Alan; Orsher, Robert; Ben-Amotz, Ron

    2018-04-16

     Various materials are used to construct splints for mid-diaphyseal tibial fracture stabilization. The objective of this study was to compare construct stiffness and inter-fragmentary bone motion when fibreglass (FG) or thermoplastic (TP) splints are applied to either the lateral or cranial aspect of the tibia in a mid-diaphyseal fracture model.  A coaptation bandage was applied to eight cadaveric canine pelvic limbs, with a custom-formed splint made of either FG or TP material applied to either the lateral or cranial aspect of the osteotomized tibia. Four-point bending tests were performed to evaluate construct stiffness and inter-fragmentary motion in both frontal and sagittal planes.  For a given material, FG or TP, construct stiffness was not affected by splint location. Construct stiffness was significantly greater with cranial FG splints than with cranial TP splints ( p  < 0.05), but this difference was not significant when comparing splints applied laterally ( p  = 0.15). Inter-fragmentary motions in the sagittal and frontal planes were similar across splint types for cranial splints, but for lateral splints there was a 64% reduction in frontal plane motion when FG was used as the splint material ( p  = 0.03).  FG produces a stiffer construct, but the difference is not reflected in a reduction in inter-fragmentary motion. For lateral splints, FG splints are associated with reduced inter-fragmentary motion as compared with TP and may therefore have slight superiority for this application. Schattauer GmbH Stuttgart.

  12. Treatment of severe porcine tracheomalacia with a 3-dimensionally printed, bioresorbable, external airway splint

    PubMed Central

    Zopf, David A.; Flanagan, Colleen L.; Wheeler, Matthew; Hollister, Scott J.; Green, Glenn E.

    2015-01-01

    Importance The study demonstrates an application for 3-dimensional (3D) printing that may serve as an effective intervention for severe tracheobronchomalacia. Objective A novel 3D printed, bioresorbable airway splint is tested for efficacy in extending survival in an animal model of severe, life-threatening tracheobronchomalacia. Participants Evaluation of an external airway splint for severe, life-threatening tracheobronchomalacia in a porcine animal model. Setting Multi-institutional and multidisciplinary collaboration between biomedical engineering laboratories and an academic animal surgery center. Interventions Experimental analysis of a 3D printed, bioresorbable airway splint is assessed in a porcine animal model of life-threatening tracheobronchomalacia. The open-cylindrical, bellow shaped porous polycaprolactone splint is placed externally and designed to suspend the underlying collapsed airway. Control animals (n=3) undergoing tracheal cartilage division and inner tracheal lumen dissociation and experimental animals (n=3) receiving the same model with overlying placement of the newly developed airway splint were evaluated. Main Outcomes and Measures An animal model for severe, life-threatening tracheobronchomalacia is proposed. Complete or near complete tracheal lumen collapse was observed in each animal with resolution of symptoms in all of the experimental animals after splint placement. Using our severe tracheobronchomalacia animal model, survival was significantly longer in duration in the experimental group receiving the airway splint after model creation when compared to model creation alone (p = 0.0495). Mortality in the experimental group was related to infection. Conclusions A multidisciplinary effort producing a CAD/CAM, bioresorbable tracheobronchial splint was tested in a porcine model of severe tracheomalacia and was found to extend survival. PMID:24232078

  13. Unilateral phthiriasis palpebrarum infestation in a child during occlusion therapy for amblyopia: Case report.

    PubMed

    Biler, Elif Demirkilinc; Selver, Ozlem Barut; Palamar, Melis; Uner, Ahmet; Uretmen, Onder

    2016-01-01

    An 8-year-old mentally retarded boy is brought to the hospital because of itching and burning at his right eye for 10 days. He was on full time right eye occlusion therapy for left amblyopia. Slit lamp examination revealed nits and adult lice anchored to the eyelashes in his occluded eye. Eyelashes and all detected lice and nits were mechanically trimmed, and sent for parasitological examination, which confirmed the diagnosis. Upon familial evaluation for additional infestation, the father was also found to have genital phthiriasis pubis and received appropriate treatment. While phthiriasis palpebrarum in children may signify sexual abuse, a detailed investigation by a child psychiatrist was performed and revealed no sign of abuse. Since the infestation was at only on occluded eye, the most possible explanation for the transmission was evaluated as the misusage of the adhesive patch in our case. In conclusion, sexual abuse should be excluded in children with phthiriasis palpebrarum and parents of amblyopic children on occlusion therapy should be warned about the importance of the hygiene of the patching in order to avoid any kind of infection and infestation.

  14. Design of an Orthopedic Product by Using Additive Manufacturing Technology: The Arm Splint.

    PubMed

    Blaya, Fernando; Pedro, Pilar San; Silva, Julia López; D'Amato, Roberto; Heras, Enrique Soriano; Juanes, Juan Antonio

    2018-02-05

    The traditional fabrication process of custom-made splints has hardly undergone any progress since the beginning of its use at the end of the eighteenth century. New manufacturing techniques and the new materials can help to modernize this treatment method of fractures. The use of Additive Manufacturing has been proposed in recent years as an alternative process for the manufacture of splints and there has been an increase in public awareness and exploration. For this reason, in this study a splint model printed in 3D, that replaces the deficiencies of the cast maintaining its virtues, has been proposed. The proposed methodology is based on three-dimensional digitalization techniques and 3D modeling with reverse engineering software. The work integrates different scientific disciplines to achieve its main goal: to improve life quality of the patient. In addition, the splint has been designed based on the principles of sustainable development. The design of splint is made of Polycarbonate by technique of Additive Manufacturing with fused deposition manufacturing, and conceived with organic shapes, customizing openings and closing buttons with rubber. In this preliminary study the final result is a prototype of the 3D printed arm splint in a reduced scale by using PLA as material.

  15. Fixation of a human rib by an intramedullary telescoping splint anchored by bone cement.

    PubMed

    Liovic, Petar; Šutalo, Ilija D; Marasco, Silvana F

    2016-09-01

    A novel concept for rib fixation is presented that involves the use of a bioresorbable polymer intramedullary telescoping splint. Bone cement is used to anchor each end of the splint inside the medullary canal on each side of the fracture site. In this manner, rib fixation is achieved without fixation device protrusion from the rib, making the splint completely intramedullary. Finite element analysis is used to demonstrate that such a splint/cement composite can preserve rib fixation subjected to cough-intensity force loadings. Computational fluid dynamics and porcine rib experiments were used to study the anchor formation process required to complete the fixation.

  16. Shin splints: MR appearance in a preliminary study.

    PubMed

    Anderson, M W; Ugalde, V; Batt, M; Gacayan, J

    1997-07-01

    To investigate the magnetic resonance (MR) imaging appearance of activity-related lower leg pain (shin splints syndrome) and evaluate the relative involvement of bone and soft tissues. Nineteen patients with activity-related lower leg pain and tenderness on palpation along the posteromedial tibia (shin splints) underwent clinical examination and MR imaging. Five also underwent plain radiography. MR findings were compared with patient demographics, clinical findings, and plain radiographs when available. Four MR patterns were identified: normal appearance (n = 7), periosteal fluid only (n = 5), abnormal marrow signal intensity (n = 5), and stress fracture (n = 2). Increased symptom duration correlated strongly with a normal MR image (P = .002). Plain radiographs appeared normal in all five patients for whom they were available. Patients with acute shin splints have a spectrum of MR findings, which suggests this clinical entity is part of a continuum of stress response in bone. The strong association between chronic symptoms and a normal-appearing MR image implies that this modality has less utility in these patients.

  17. How Dutch orthoptists deal with noncompliance with occlusion therapy for amblyopia.

    PubMed

    Tjiam, A M; Vukovic, E; Asjes-Tydeman, W L; Holtslag, G; Loudon, S E; Sinoo, M M; Simonsz, H J

    2010-12-01

    We previously found that compliance with occlusion therapy for amblyopia is poor, especially among children of non-native parents who spoke Dutch poorly and who were low educated. We investigated conception, awareness, attitude, and actions to deal with noncompliance among Dutch orthoptists. Orthoptists working in non-native, low socioeconomic status (SES) areas and a selection of orthoptists working elsewhere in the Netherlands were studied. They were observed in their practice, received a structured questionnaire, and underwent a semi-structured interview. Finally, a short survey was sent to all working orthoptists in the Netherlands. Nine orthoptists working in non-native, low-SES areas and 23 working elsewhere in the Netherlands participated. One hundred and fifty-one orthoptists returned the short survey. Major discrepancies existed in conception, awareness, and attitude. Opinions differed on what should be defined as noncompliance and on what causes noncompliance. Some orthoptists found noncompliance annoying, unpleasant, and hard to imagine, others were more understanding. Many pitied the noncompliant child. Almost all thought that the success of occlusion therapy lies both with the parents and the orthoptist, but one third thought that noncompliance was not solely their responsibility. Patients' compliance was estimated at 69.3% in non-native, low-SES areas (electronically, 52% had been measured), at 74.1% by the other 23 orthoptists, and at 73.8% in the short survey. Actions to improve compliance were diverse; some increased occlusion hours whereas others decreased them. In non-native, low-SES areas, 22% spoke Dutch moderately to none; the allotted time for a patient's first visit was 21'; the time spent on explaining to the parents was 2'30" and to the child 10". In practices of the other 23 orthoptists, 6% spoke Dutch moderately to none (P<0.0001), the time for a patient's first visit was 27'24" (P=0.47), and the periods spent explaining were 2'51" (P=0

  18. Assessment of platelet-derived growth factor using A splinted full thickness dermal wound model in bearded dragons (Pogona vitticeps).

    PubMed

    Keller, Krista A; Paul-Murphy, Joanne; Weber, E P Scott; Kass, Philip H; Guzman, Sanchez-Migallon David; Park, Shin Ae; Raghunathan, Vijay Krishna; Gustavsen, Kate A; Murphy, Christopher J

    2014-12-01

    Wounds in reptiles are a common reason for presentation to a veterinarian. At this time there is limited information on effective topical medications to aid in wound closure. The objectives of this study were to translate the splinted, full-thickness dermal wound model, validated in mice, to the bearded dragon (Pogona vitticeps) and to determine the effect of topical becaplermin (BP), a platelet-derived growth factor (0.01%), on the rate of wound closure. Ten bearded dragons were anesthetized and two full-thickness cutaneous wounds were made on the dorsum of each lizard. Encircling splints were applied surrounding each wound and subsequently covered by a semi-occlusive dressing. Five lizards had one wound treated with BP and the adjacent wound treated with a vehicle control. Five additional lizards had one wound treated with saline and the second wound treated with a vehicle control. Wounds were imaged daily, and the wound area was measured using digital image analysis. The change in percentage wound closure over 17 days and the time to 50% wound closure was compared among the four treatment groups. There was no significant difference in wound closure rates between BP-treated and saline-treated wounds or in the time to 50% wound closure between any treatments. Vehicle-treated wounds adjacent to saline-treated wounds closed significantly slower than did BP (P < 0.010), saline (P < 0.001), and vehicle-treated wounds adjacent to BP-treated wounds (P < 0.013). Our preliminary study indicates that the splinted wound model, with modifications, may be used to determine wound closure rates in bearded dragons. When compared with saline, BP did not have a significant effect on wound closure rates, while the vehicle alone delayed wound closure. Histologic analysis of experimentally created wounds throughout the wound healing process is needed to further evaluate the effects of these treatments on reptile dermal wound healing.

  19. Psychosocial distress of part-time occlusion in children with intermittent exotropia.

    PubMed

    Kim, Ungsoo Samuel; Park, Subin; Yoo, Hee Jeong; Hwang, Jeong-Min

    2013-01-01

    To evaluate the psychosocial distress of part-time occlusion therapy in intermittent exotropia. A total of 25 children (15 males and 10 females, aged 3 to 7 years, mean age 4.7 years) with intermittent exotropia were enrolled. Behavioral and psychosocial problems were assessed by the Korean Child Behavior Checklist (K-CBCL), which consists of eight categories of withdrawal, somatic problems, depression/anxiety, social problems, thought problems, attention problems, delinquent behavior, and aggressive behavior, and the Amblyopia Treatment Index (ATI). The ATI was designed to evaluate the three factors of compliance, adverse effect, and social stigma. The Parenting Stress Index (PSI) is a parent self-report designed to identify potentially dysfunctional parent-child systems. The K-CBCL was obtained before and after occlusion therapy, and the ATI and PSI were taken from parents only after occlusion therapy. We evaluated the change on the K-CBCL and the correlation between the K-CBCL and ATI. The attention problem assessed by the K-CBCL significantly decreased after occlusion therapy. On the ATI, the social stigma was relatively lower than compliance and adverse effect factors (Likert scale 2.64, 3.11, and 3.11, respectively). The somatic problem assessed by the K-CBCL and compliance on the ATI were significantly correlated (p = 0.014). There was no significant change in percentile scores of each subscale (parental dominant scale and child dominant scale) of the PSI. Total stress index before and after occlusion therapy was 97.16 ± 8.38 and 97.00 ± 8.16 respectively (p = 0.382). Occlusion therapy may influence the psychosocial impact on intermittent exotropia patients. Part-time occlusion significantly decreased the attention problem in children with intermittent strabismus. Children with a high somatic problem score on the KCBCL showed poor compliance to the part-time occlusion.

  20. [Physical therapy for scars].

    PubMed

    Masanovic, Marguerite Guillot

    2013-01-01

    Physical therapy consists notably of hand or mechanical massages, pressure therapy using various fabrics or splints, cryotherapy, laser therapy, etc. It forms part of the range of therapies used to treat pathological scars, including medical and surgical treatment. While the results are often satisfactory for hypertrophic scars, they remain uncertain for major keloids.

  1. Influence of the Lower Jaw Position on the Running Pattern.

    PubMed

    Maurer, Christian; Stief, Felix; Jonas, Alexander; Kovac, Andrej; Groneberg, David Alexander; Meurer, Andrea; Ohlendorf, Daniela

    2015-01-01

    The effects of manipulated dental occlusion on body posture has been investigated quite often and discussed controversially in the literature. Far less attention has been paid to the influence of dental occlusion position on human movement. If human movement was analysed, it was mostly while walking and not while running. This study was therefore designed to identify the effect of lower jaw positions on running behaviour according to different dental occlusion positions. Twenty healthy young recreational runners (mean age = 33.9±5.8 years) participated in this study. Kinematic data were collected using an eight-camera Vicon motion capture system (VICON Motion Systems, Oxford, UK). Subjects were consecutively prepared with four different dental occlusion conditions in random order and performed five running trials per test condition on a level walkway with their preferred running shoes. Vector based pattern recognition methods, in particular cluster analysis and support vector machines (SVM) were used for movement pattern identification. Subjects exhibited unique movement patterns leading to 18 clusters for the 20 subjects. No overall classification of the splint condition could be observed. Within individual subjects different running patterns could be identified for the four splint conditions. The splint conditions lead to a more symmetrical running pattern than the control condition. The influence of an occlusal splint on running pattern can be confirmed in this study. Wearing a splint increases the symmetry of the running pattern. A more symmetrical running pattern might help to reduce the risk of injuries or help in performance. The change of the movement pattern between the neutral condition and any of the three splint conditions was significant within subjects but not across subjects. Therefore the dental splint has a measureable influence on the running pattern of subjects, however subjects individuality has to be considered when choosing the optimal splint

  2. Shin splints and forefoot contact running: a case report.

    PubMed

    Cibulka, M T; Sinacore, D R; Mueller, M J

    1994-08-01

    Many athletes develop shin splints after athletic activity. The purpose of this case report is to describe the treatment of a patient with posteromedial tibial pain (shin splints) who habitually ran with a forefoot contact running style. The 20-year-old male patient, who played volleyball and basketball about 7 hours a week, complained of pain in the middle one-third of the posteromedial tibia after an acute but prolonged episode of running. Routine observational analysis and in-shoe pressure analysis of the patient's running style showed that he habitually ran on his toes with an absence of heelstrike (forefoot contact running). After instructing the patient on heel-toe running, he no longer complained of posteromedial tibial bone pain. Several possible reasons are proposed for the reduction of leg pain following cessation of forefoot contact running. This case report proposes forefoot contact running as a possible contributor to posteromedial shin splints and that a change in running style may be the optimal treatment for some patients.

  3. Psychological causes of non-compliance with electronically monitored occlusion therapy for amblyopia.

    PubMed

    Loudon, S E; Passchier, J; Chaker, L; de Vos, S; Fronius, M; Harrad, R A; Looman, C W N; Simonsz, B; Simonsz, H J

    2009-11-01

    To analyse psychological causes for low compliance with occlusion therapy for amblyopia. In a randomised trial, the effect of an educational programme on electronically measured compliance had been assessed. 149 families who participated in this trial completed a questionnaire based on the Protection Motivation Theory after 8 months of treatment. Families with compliance less than 20% of prescribed occlusion hours were interviewed to better understand their cause for non-compliance. Poor compliance was most strongly associated with a high degree of distress (p<0.001), followed by low perception of vulnerability (p = 0.014), increased stigma (p = 0.017) and logistical problems with treatment (p = 0.044). Of 44 families with electronically measured compliance less than 20%, 28 could be interviewed. The interviews confirmed that lack of knowledge, distress and logistical problems resulted in non-compliance. Poor parental knowledge, distress and difficulties implementing treatment seemed to be associated with non-compliance. For the same domains, the scores were more favourable for families who had received the educational programme than for those who had not.

  4. How I Manage Shin Splints.

    PubMed

    Andrish, J; Work, J A

    1990-12-01

    Shin splints are a common problem for athletes whose sports involve a repeated, jarring impact to the leg. Often they are due to a change in activity level. Stopping the activity until the pain subsides, and then gradually working back up to the desired level is generally the best treatment and protection against recurrence.

  5. A supplemental video teaching tool enhances splinting skills.

    PubMed

    Mehrpour, Saeed Reza; Aghamirsalim, Mohamadreza; Motamedi, Seyed Mohammad Kalantar; Ardeshir Larijani, Fatemeh; Sorbi, Reza

    2013-02-01

    The ability to apply casts and splints is a technical skill that requires practice and understanding of basic principles of musculoskeletal medicine. A video in which a given procedure is simulated on a dummy can represent reality under controlled conditions. A decrease in physician competency in musculoskeletal medicine is the result of educational deficiencies at the medical school level. We asked whether (1) a supplemental video educational program enhances performance of medical students' musculoskeletal clinical skills and (2) factors such as the proportion of orthopaedic professors to students, sex, age, and previous scores of medical students affected the clinical skills of medical students. We allocated 474 medical students into one of two groups: all participants received 90 minutes of lecture instruction on how to splint and cast but one group viewed the supplemental instructional video and the other did not. There were no differences in terms of sex, age, basic science exam scores, or grade point average of the groups. Thirteen specific skills in splinting an injured limb were evaluated. We recorded grade point averages. We developed a 10-point scoring system and graded each student on their splinting skills 6 months after the lectures. The medical students who watched the video had an average score of 7.6, whereas the control group's average score was 2.0. We observed a positive association between watching the educational video and clinical exam score. A higher professor-to-student ratio was associated with lower student Objective Structured Clinical Examination score. Our observations suggest a supplemental video instructional program improved the performance of musculoskeletal clinical skills in comparison to only a traditional lecture series.

  6. 21 CFR 890.3675 - Denis Brown splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3675 Denis Brown splint. (a... on young children with tibial torsion (excessive rotation of the lower leg) or club foot. (b...

  7. PDGF-BB Does Not Accelerate Healing in Diabetic Mice with Splinted Skin Wounds

    PubMed Central

    Shah, Nihar M.; Teixeira, Leandro; Motta, Monica J.; Covert, Jill; Dubielzig, Richard; Schurr, Michael; Isseroff, Roslyn Rivkah; Abbott, Nicholas L.; McAnulty, Jonathan; Murphy, Christopher J.

    2014-01-01

    Topical application of platelet-derived growth factor-BB (PDGF-BB) is considered to accelerate tissue repair of impaired chronic wounds. However, the vast literature is plagued with conflicting reports of its efficacy in animal models and this is often influenced by a wide array of experimental variables making it difficult to compare the results across the studies. To mitigate the confounding variables that influence the efficacy of topically applied PDGF-BB, we used a controlled full thickness splinted excisional wound model in db/db mice (type 2 diabetic mouse model) for our investigations. A carefully-defined silicone-splinted wound model, with reduced wound contraction, controlled splint and bandage maintenance, allowing for healing primarily by reepithelialization was employed. Two splinted 8 mm dorsal full thickness wounds were made in db/db mice. Wounds were topically treated once daily with either 3 µg PDGF-BB in 30 µl of 5% PEG-PBS vehicle or an equal volume of vehicle for 10 days. Body weights, wound contraction, wound closure, reepithelialization, collagen content, and wound bed inflammation were evaluated clinically and histopathologically. The bioactivity of PDGF-BB was confirmed by in vitro proliferation assay. PDGF-BB, although bioactive in vitro, failed to accelerate wound healing in vivo in the db/db mice using the splinted wound model. Considering that the predominant mechanism of wound healing in humans is by re-epeithelialization, the most appropriate model for evaluating therapeutics is one that uses splints to prevent excessive wound contraction. Here, we report that PDGF-BB does not promote wound closure by re-epithelialization in a murine splinted wound model. Our results highlight that the effects of cytoactive factors reported in vivo ought to be carefully interpreted with critical consideration of the wound model used. PMID:25121729

  8. Does compliance with amblyopia management improve following supervised occlusion treatment?

    PubMed

    El-Ghrably, I A; Longville, D; Gnanaraj, L

    2007-01-01

    To demonstrate improvement in compliance following supervised occlusion therapy for amblyopia in children who had failed to respond to outpatient treatment. Retrospective review of the visual outcome of 30 children who were admitted to an ophthalmology ward for 1-day intensive supervised occlusion. These children had documented poor compliance and previously failed to respond to the outpatient occlusion treatment. During their stay a trained ophthalmology nurse educated parents regarding amblyopia and the benefits of occlusion therapy. Visual acuity (VA) of the amblyopic and fellow eyes was recorded on admission, discharge, and at each subsequent visit. The compliance was recorded from parent's history and also indirectly by noticing improvement in vision. The mean supervised occlusion was 7.4 hours (range 4-12 hours). The compliance with occlusion therapy improved in 23 children (77%) after discharge. The mean duration of occlusion after discharge improved to 4 hours (range 1-12 hours). The mean follow-up was 18 months (range 4-24 months). Though there was no dramatic improvement in VA at discharge there was a statistically significant improvement in VA between admission and last recorded VA (p<0.0001). Of the 23 children who were compliant with occlusion following discharge, 21 (91%) gained at least one line of acuity in their amblyopic eye on the last assessment of their VA and five of them achieved 6/12. Of the seven children who did not comply with occlusion following discharge, only one patient gained one line improvement in his amblyopic eye. This study shows that supervised occlusion treatment and parental education was effective in children who had initially failed traditional outpatient treatment.

  9. Relieving Painful 'Shin Splints'.

    PubMed

    Fick, Daniel S; Albright, John P; Murray, Boyd P

    1992-12-01

    In brief Shin splints, or more precisely, medial tibial stress syndrome (MTSS), are painful and troublesome. Despite treatment or activity modification, they often recur. Distinguishing MTSS, the most common running overuse injury, from other overuse injuries can help focus treatment, which starts conservatively. Recommending activity modification, ice massage, NSAIDs, and stretching is a good first step. Patients who don't respond to treatment may need additional diagnostic workup and more restrictive activity guidelines.

  10. Some biomechanical aspects of the foot and ankle in athletes with and without shin splints.

    PubMed

    Viitasalo, J T; Kvist, M

    1983-01-01

    Thirteen adult male athletes (long-distance runners and orienteerers without foot problems) and 35 male athletes with shin splints were compared with respect to: 1) the position of the lower leg and the heel while standing, 2) the passive range of mobility in the subtalar joint, and 3) the angular displacement between the calcaneus and the midline of the lower leg (Achilles tendon angle) while running with bare feet on a treadmill. In standing, the two groups differed statistically significantly in the Achilles tendon angle, which values were greater in the shin splint group. With respect to passive mobility, the athletes with shin splints had significantly greater (P less than 0.05-0.01) angular displacement values in inversion, eversion, and in their sum than the control group. While running, the Achilles tendon angle of the shin splint group was significantly greater (P less than 0.01) at the heel strike. Further, the shin splints group had a significantly greater (P less than 0.01) angular displacement between the heel strike and the maximal everted position. The results suggest structural and functional differences in the feet and ankles between healthy athletes and those with shin splints.

  11. Bridging Therapy with i. v. rtPA in MCA Occlusion Prior to Endovascular Thrombectomy: a Double-Edged Sword?

    PubMed

    Kaesmacher, Johannes; Kleine, Justus F

    2018-03-01

    Recent studies suggested that preinterventional intravenous (i. v.) recombinant tissue plasminogen activator (rtPA) as bridging therapy facilitates successful and fast vessel recanalization in endovascular stroke treatment (EST); however, data on this effect and the associated clinical value are discrepant. This study examined if this discrepancy could be related to an effect-modifying variable, specifically to the exact occlusion site. Retrospective analysis of 239 patients with acute occlusion of the middle cerebral artery (MCA) treated with up to date endovascular techniques. Effects of i. v.-rtPA bridging on clinical outcomes and safety/efficacy of EST, defined as the respective rates of successful, first pass and thrombolysis in cerebral infarction (TICI) scale 3 recanalization, were evaluated and stratified according to distal versus proximal occlusion sites. Overall, i. v.-rtPA bridging was associated with a significantly higher rate of successful recanalization (86.9 % vs. 75.7 %, p = 0.028). i. v.-rtPA bridging-related effects, however, were observable only in distal, but not in proximal MCA-occlusions. In distal occlusions, i. v.-rtPA clearly favored successful recanalization (adj. OR 4.6, 95 %-CI 1.5-13.6, p = 0.006) and first-pass successes (adj. OR 2.8, 95 %-CI 1.0-7.6, p = 0.042), but tended to be associated with lower rates of complete (TICI-3) reperfusion (adj. OR 0.4, 95 %-CI 0.2-1.1, p = 0.068). The net effect was a small clinical benefit, reflected in higher rates of strong neurological improvement (adj. OR: 2.8, 95 %-CI: 1.1-6.9, p = 0.03). i. v.-rtPA-bridging-related effects are occlusion site-dependent, paralleling similar effects of systemic i. v.-rtPA when applied without subsequent endovascular therapy. In distal occlusions, i. v.-rtPA facilitates thrombectomy, but may also promote distal embolization, with a small clinical benefit as overall net effect. Randomized trials assessing i.v-rtPA bridging need

  12. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    PubMed

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  13. 21 CFR 872.3890 - Endodontic stabilizing splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. An endodontic stabilizing splint is a device made of a material, such as titanium, intended to be inserted through the root canal into the upper or lower jaw bone to stabilize a tooth. (b) Classification...

  14. A randomized single blind crossover trial comparing leather and commercial wrist splints for treating chronic wrist pain in adults

    PubMed Central

    Thiele, Jill; Nimmo, Rachel; Rowell, Wendy; Quinn, Stephen; Jones, Graeme

    2009-01-01

    Background To compare the effectiveness of a custom-made leather wrist splint (LS) with a commercially available fabric splint (FS) in adults with chronic wrist pain. Methods Participants (N = 25, mean age = 54) were randomly assigned to treatment order in a 2-phase crossover trial. Splints were worn for 2 weeks, separated by a one-week washout period. Outcomes were assessed at baseline and after each splint phase using the Australian/Canadian Osteoarthritis Hand Index (AUSCAN), the Canadian Occupational Performance Measure (COPM) and Jamar dynamometer by an observer blinded to treatment allocation. Results Both styles of wrist splint significantly reduced pain (effect size LS 0.79, FS 0.43), improved hand function and increased grip strength compared to baseline (all p < 0.05) with no increase in wrist stiffness. There was a consistent trend for the LS to be superior to the FS but this was statistically significant only for patient perceived occupational performance (p = 0.008) and satisfaction (p = 0.015). Lastly, 72% of patients preferred the custom-made leather splint compared to the commercially available splint. Conclusion Leather wrist splints were superior to a commercially available fabric splint for the short-term relief of pain and dysfunction. PMID:19843345

  15. Photomodulation in the treatment of chronic pain in patients with temporomandibular disorder: protocol for cost-effectiveness analysis

    PubMed Central

    Sobral, Ana Paula Taboada; de Godoy, Camila Leal H; Fernandes, Kristianne P Santos; Bussadori, Sandra Kalil; Ferrari, Raquel Agnelli Mesquita; Monken, Sonia F

    2018-01-01

    Introduction Epidemiological data show that the signs and symptoms of temporomandibular disorder (TMD) start becoming apparent from 6 years of age, and during adolescence these signs and symptoms are similar to those of adults. The present study aims to estimate the direct costs for treatment of chronic muscle pain with photobiomodulation therapy, occlusal splint and placebo in patients with TMD; to evaluate the effectiveness of photobiomodulation therapy and occlusal splint for treatment of muscle pain in patients with TMD; to analyse the cost-effectiveness of the two proposed treatments for pain; and to describe and compare the results of the analyses of these treatments. Methods and analysis This is a prospective trial of clinical and economic analyses that will include 135 patientswith TMD aged between 15 years and 25 years, randomly assigned to a treatment group: G1 (photobiomodulation), G2 (occlusal splint) and G3 (placebo). The analyses will be based on the cost of each treatment during the 12-month period. The outcome of the analysis of effectiveness will be pain, measured periodically by means of clinical examination of Research Diagnostic Criteria for Temporomandibular Disorders. The cost-effectiveness ratio will be calculated using, as end points, pain and the ratio of the differences in costs between the groups studied. The evaluation of the impact of the treatment on quality of life will be determined by applying the adapted EuroQol-5D. Ethics and dissemination This protocol has been ethically approved by the local medical ethical committee, protocol number 2.014.339. Results will be submitted to international peer-reviewed journals and presented at international conferences. Trial registration number NCT03096301. PMID:29730613

  16. Endobronchial occlusive disease: Nd:YAG or PDT?

    NASA Astrophysics Data System (ADS)

    Regal, Anne-Marie; Takita, Hiroshi

    1991-06-01

    Patients with endobronchial occlusion commonly experience dyspnea, cough, hemoptysis, pneumonitis, and atelectasis. If luminal patency is not re-established, obstructive symptoms may progress to sepsis and death. Although the overall survival of patients with lung cancer may not be altered by relief of airway obstruction, the prognosis for this subset of patients may be improved by eliminating the septic complications of bronchial occlusion. Techniques to treat occluded bronchi include electro-fulguration, cryotherapy, brachytherapy, laser (CO2, Nd-YAG) therapy, and photodynamic therapy (PDT). These represent local forms of treatment and are intended to be palliative. Nd-YAG and PDT are the modalities more frequently utilized in this setting. Comparison of the two treatment forms may furnish insight regarding the appropriate role for each as individual therapies and as part of the armamentarium of cancer therapies.

  17. A Method for Direct Fabrication of a Lingual Splint for Management of Pediatric Mandibular Fractures

    PubMed Central

    Davies, Sarah; Costello, Bernard J.

    2013-01-01

    Summary: Pediatric mandibular fractures have successfully been managed in various ways. The use of a lingual splint is one such option. The typical indirect method for acrylic lingual splint fabrication involves obtaining dental impressions. Dental models are produced from those impressions so that model surgery may be performed. The splint is then made on those models using resin powder and liquid monomer in a wet laboratory and transferred to the patient. Obvious limitations to this technique exist for both patient and operator. We present a technique for direct, intraoperative, fabrication of a splint using commercially available light-cured material that avoids some of the shortcomings of the indirect method. Recommendations are made based on available material safety information. PMID:25289246

  18. The Effect of Distal Location of the Volar Short Arm Splint on the Metacarpophalangeal Joint Motion.

    PubMed

    Kim, Joon Yub; Sohn, Dong Wook; Park, Ho Youn; Yoo, Jeong Hyun; Kim, Joo Hak; Jung, Myung Gon; Cho, Jae Ho

    2016-06-01

    The goals of this study were to compare maximal metacarpophalangeal joint (MCPJ) flexion angles after application of a volar short arm splint at 3 different locations and verify the relations between the three different physical and radiological locations. Forty dominant hands of healthy subjects were analyzed in the study. We defined a transverse skin folding line as a line drawn from the radial aspect of the thenar crease to the ulnar aspect of the distal transverse palmar crease. The distal end of the volar short arm splint was applied on 3 parallel locations to this line. Location A was on this transverse skin folding line; location B was 1 cm proximal to location A; and location C was 1 cm distal to location A. Two orthopedic surgeons measured the maximal MCPJ flexion angles of each finger except the thumb with the application of a volar short arm splint at 3 different locations as well as without a splint as a control. Radiological locations of the 3 different distal ends of the volar short arm splint were also assessed by anteroposterior radiographs of the wrist. When the splint was applied at location A and C, the maximal MCPJ flexion angle decreased to a mean of 83° (91% of control value) and 56° (62% of control value), respectively (compared to the control, p < 0.001). At location B, the maximal MCPJ flexion angle was a mean of 90° (99% of control value); no significant difference was observed compared to the control or without the splint (p = 0.103). On radiography, the average length from the metacarpal head to the distal end of the splint at all fingers decreased in the order of location B, A, and C (29 mm, 19 mm, and 10 mm, respectively; p < 0.001). We recommend applying the distal end of a volar short arm splint at proximal 1 cm to the transverse skin folding line to preserve MCPJ motion perfectly, which is located at distal 44% of the whole metacarpal bone length radiologically.

  19. Use of a splint following open carpal tunnel release: a comparative study.

    PubMed

    Cebesoy, Oguz; Kose, Kamil Cagri; Kuru, Ilhami; Altinel, Levent; Gul, Rauf; Demirtas, Mehmet

    2007-01-01

    This study was undertaken to compare the clinical effectiveness and costs of postoperative splintage and late rehabilitation with a bulky bandage dressing versus early rehabilitation after carpal tunnel release. In this comparative study, 46 patients were randomly divided into 2 groups. In each group, 3 patients were excluded because of improper follow-up, leaving a total of 40 patients. Group 1 used a splint (exercises given 3 wk postoperatively) and group 2 was given a bulky bandage (exercises provided immediately) after open release. Patients were assessed preoperatively and at the first and third postoperative months with the Questionnaire of Levine for Clinical Assessment of Carpal Tunnel Syndrome. The 2 groups were similar in terms of preoperative functional status scores and in controls at the first and third months (P=.549, P=.326, P=.190). When both groups were compared, no statistical significance was found regarding symptom severity scale scores preoperatively and at the first postoperative month (P=.632 vs P=.353). At the third month, scores were lower in favor of group 2 (P=.023). Additionally, 16 of 20 patients (80%) in group 1 reported a heavy feeling and discomfort caused by the splint. This problem was not reported by the patients in group 2. The cheapest splint on the market was 9 times more expensive than a bulky dressing. The investigators concluded that postoperative immobilization with a splint has no detectable benefits. Use of bulky dressings and abandonment of the use of postoperative splints may prevent unnecessary expenditures without sacrificing patient comfort or compromising the course of healing in carpal tunnel surgery.

  20. Positioning, Splinting, and Contracture Management

    DTIC Science & Technology

    2011-01-01

    IP) joints in extension, thumb in palmar abduction, hip extension and abducted 20 (no external rotation), knee extension, and neutral ankle ...to skin breakdown are the heels,55 sacrum, ankles , wrists, elbows, and occipital area.8 Some options for splinting and positioning devices can be...children.70 In addition, moveable parts are difficult to anchor to small levers and the cognition and responsibilities needed for proper fit of dynamic

  1. Temporomandibular joint fibrocartilage degeneration from unilateral dental splints.

    PubMed

    Henderson, Sarah E; Lowe, Jesse R; Tudares, Mauro A; Gold, Michael S; Almarza, Alejandro J

    2015-01-01

    The objective of this study was to determine the extent to which altered loading in the temporomandibular joint (TMJ), as might be associated with a malocclusion, drives degeneration of articulating surfaces in the TMJ. We therefore sought to quantify the effects of altered joint loading on the mechanical properties and biochemical content and distribution of TMJ fibrocartilage in the rabbit. Altered TMJ loading was induced with a 1mm splint placed unilaterally over the maxillary and mandibular molars for 6 weeks. At that time, TMJ fibrocartilage was assessed by compression testing, biochemical content (collagen, glycosaminoglycan (GAG), DNA) and distribution (histology), for both the TMJ disc and the condylar fibrocartilage. There were no changes in the TMJ disc for any of the parameters tested. The condylar fibrocartilage from the splinted animals was significantly stiffer and the DNA content was significantly lower than that in control animals. There was significant remodeling in the condylar fibrocartilage layers as manifested by a change in GAG and collagen II distribution and a loss of defined cell layers. A connection between the compressive properties of TMJ condylar fibrocartilage after 6 weeks of splinting and the changes in histology was observed. These results suggest a change in joint loading leads to condylar damage, which may contribute to pain associated with at least some forms of TMJ disease. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Temporomandibular Joint Fibrocartilage Degeneration from Unilateral Dental Splints

    PubMed Central

    Henderson, Sarah E.; Lowe, Jesse R.; Tudares, Mauro A.; Gold, Michael S.; Almarza, Alejandro J.

    2014-01-01

    Objective The objective of this study was to determine the extent to which altered loading in the temporomandibular joint (TMJ), as might be associated with a maloclussion, drives degeneration of articulating surfaces in the TMJ. We therefore sought to quantify the effects of altered joint loading on the mechanical properties and biochemical content and distribution of TMJ fibrocartilage in the rabbit. Design Altered TMJ loading was induced with a 1 mm splint placed unilaterally over the maxillary and mandibular molars for six weeks. At that time, TMJ fibrocartilage was assessed by compression testing, biochemical content (collagen, glycosaminoglycan (GAG), DNA) and distribution (histology), for both the TMJ disc and the condylar fibrocartilage. Results There were no changes in the TMJ disc for any of the parameters tested. The condylar fibrocartilage from the splinted animals was significantly stiffer and the DNA content was significantly lower than that in control animals. There was significant remodeling in the condylar fibrocartilage layers as manifested by a change in GAG and collagen II distribution and a loss of defined cell layers. Conclusions A connection between the compressive properties of TMJ condylar fibrocartilage after 6 weeks of splinting and the changes in histology was observed. These results suggest a change in joint loading, leads to condylar damage, which may contribute to pain associated with at least some forms of TMJ disease. PMID:25247778

  3. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    PubMed Central

    Kothari, Mihir

    2014-01-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa. PMID:23571255

  4. Occlusion-amblyopia following high dose oral levodopa combined with part time patching.

    PubMed

    Kothari, Mihir

    2014-12-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  5. The relationship between Shin Splints with anthropometric characteristics and some indicators of body composition.

    PubMed

    Sabeti, V; Khoshraftar Yazdi, N; Bizheh, N

    2014-10-06

    Medial tibial stress syndrome (MTSS), commonly known as ''shin splints,'' is a frequent injury of the lower extremity and one of the most common causes of exertional leg pain in athletes. The aim of this study was to study the relationship between Shin splints, anthropometric characteristics and some indicators of body composition. In this descriptive - comparative study, thirty--five students of physical education were evaluated in two groups: Shin Splints group [(n=17) , mean (± SD) height and weight, 161.52 ± 5.32 and 56.85 ± 9.30 respectively] and healthy group [(n=18) ,mean (± SD) height and weight, 162.75 ± 3.85 and 54.73 ± 6.36 respectively]. Anthropometric and body composition characteristic of both groups were studied under identical conditions. Independent t--test was performed in order to analyze the data. No significant differences were found in anthropometric parameters (thigh length, leg length, foot length and leg circumference) body composition (the amount of minerals and body fat percentage) between the healthy group and the Shin Splints group (P> 0/05). According to the results of this study, anthropometric characteristics and body composition indicators may not be regarded as a risk factor for shin splints.

  6. The effects of the time of intranasal splinting on bacterial colonization, postoperative complications, and patient discomfort after septoplasty operations.

    PubMed

    Karatas, Abdullah; Pehlivanoglu, Filiz; Salviz, Mehti; Kuvat, Nuray; Cebi, Isil Taylan; Dikmen, Burak; Sengoz, Gonul

    The main reason for nasal tampon placement after septoplasty is to prevent postoperative hemorrhage, while the secondary purpose is internal stabilization after operations involving the cartilaginous-bony skeleton of the nose. Silicone intranasal splints are as successful as other materials in controlling postoperative hemorrhages of septal origin. The possibility of leaving the splints intranasally for extended periods helps stabilize the septum in the midline. However, there is nothing in the literature about how long these splints can be retained inside the nasal cavity without increasing the risk of infection, postoperative complications, and patient discomfort. The current study aimed to evaluate the association between the duration of intranasal splinting and bacterial colonization, postoperative complications, and patient discomfort. Patients who had undergone septoplasty were divided into three groups according to the day of removal of the silicone splints. The splints were removed on the fifth, seventh, and tenth postoperative days. The removed splints were microbiologically cultured. Early and late complications were assessed, including local and systemic infections, tissue necrosis, granuloma formation, mucosal crusting, synechia, and septal perforation. Postoperative patient discomfort was evaluated by scoring the levels of pain and nasal obstruction. No significant difference was found in the rate of bacterial colonization among the different groups. Decreased mucosal crusting and synechia were detected with longer usage intervals of intranasal silicone splints. Postoperative pain and nasal obstruction were also diminished by the third postoperative day. Silicone splints were well tolerated by the patients and any negative effects on postoperative patient comfort were limited. In fact, prolonged splint usage intervals reduced late complications. Long-term silicone nasal splint usage is a reliable, effective, and comfortable method in patients with

  7. A randomized controlled trial of cast versus splint for distal radial buckle fracture: an evaluation of satisfaction, convenience, and preference.

    PubMed

    Williams, Kristine G; Smith, Gillian; Luhmann, Scott J; Mao, Jingnan; Gunn, Joseph D; Luhmann, Janet D

    2013-05-01

    Buckle fractures are inherently stable and at low risk for displacement. These advantages allow for treatment options that may create confusion for the practitioner. Accepted immobilization methods include circumferential cast, plaster or prefabricated splint, and soft bandaging. Despite mounting evidence for splinting, the questions of pain, preference, satisfaction, and convenience offer a challenge to changing practice. The purposes of this study were (1) to compare cast versus splint for distal radial buckle fractures in terms of parental and patient satisfaction, convenience, and preference and (2) to compare pain reported for cast versus splint. We conducted a prospective randomized trial of a convenience sample of patients 2 through 17 years with a radiologically confirmed distal radial buckle fracture. Subjects were randomly assigned to short-arm cast or prefabricated wrist splint. We assessed satisfaction, convenience, preference, and pain in the emergency department and at days 1, 3, 7, and 21 after immobilization. Ninety-four patients were enrolled. Compared with the cast group, those in the splint group reported higher levels of satisfaction, preference, and convenience on 10-point visual analog scale. Although pain scores were higher for those in the splint group, the difference was not statistically significant. With the exception of pain reported in the emergency department being higher for the splinted group, all other measures, including convenience, satisfaction, and preference, showed a clear trend favoring splints at almost every time period in the study. This study provides additional evidence that splinting is preferable to casting for the treatment of distal radial buckle fractures.

  8. Outcomes and stability in patients with anterior open bite and long anterior face height treated with temporary anchorage devices and a maxillary intrusion splint

    PubMed Central

    Scheffler, Nicole R.; Proffit, William R.; Phillips, Ceib

    2015-01-01

    Introduction Temporary skeletal anchorage devices now offer the possibility of closing anterior open bites and decreasing anterior face height by intruding maxillary posterior teeth, but data for treatment outcomes are lacking. This article presents outcomes and posttreatment changes for consecutive patients treated with a standardized technique. Methods The sample included 33 consecutive patients who had intrusion of maxillary posterior teeth with a maxillary occlusal splint and nickel-titanium coil springs to temporary anchorage devices in the zygomatic buttress area, buccal and apical to the maxillary molars. Of this group, 30 had adequate cephalograms available for the period of treatment, 27 had cephalograms including 1-year posttreatment, and 25 had cephalograms from 2 years or longer. Results During splint therapy, the mean molar intrusion was 2.3 mm. The mean decrease in anterior face height was 1.6 mm, less than expected because of a 0.6-mm mean eruption of the mandibular molars. During the postintrusion orthodontics, the mean change in maxillary molar position was a 0.2-mm extrusion, and there was a mean 0.5-mm increase in face height. Positive overbite was maintained in all patients, with a slight elongation (<2 mm) of the incisors contributing to this. During the 1 year of posttreatment retention, the mean changes were a further eruption of 0.5 mm of the maxillary molars, whereas the mandibular molars intruded by 0.6 mm, and there was a small decrease in anterior face height. Changes beyond 1 year posttreatment were small and attributable to growth rather than relapse in tooth positions. Conclusions Intrusion of the maxillary posterior teeth can give satisfactory correction of moderately severe anterior open bites, but 0.5 to 1.5 mm of reeruption of these teeth is likely to occur. Controlling the vertical position of the mandibular molars so that they do not erupt as the maxillary teeth are intruded is important in obtaining a decrease in face height

  9. 21 CFR 878.3910 - Noninflatable extremity splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Noninflatable extremity splint. 878.3910 Section 878.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3910 Noninflatable...

  10. 21 CFR 878.3910 - Noninflatable extremity splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Noninflatable extremity splint. 878.3910 Section 878.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3910 Noninflatable...

  11. 21 CFR 878.3910 - Noninflatable extremity splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Noninflatable extremity splint. 878.3910 Section 878.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3910 Noninflatable...

  12. 21 CFR 878.3910 - Noninflatable extremity splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Noninflatable extremity splint. 878.3910 Section 878.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3910 Noninflatable...

  13. 21 CFR 878.3910 - Noninflatable extremity splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Noninflatable extremity splint. 878.3910 Section 878.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3910 Noninflatable...

  14. The Effect of Dexpanthenol-Vitamin A (Nazalnem) on Silastic Splints After Nasal Septal Surgery.

    PubMed

    Yildirim, Güven; Kumral, Tolgar Lütfi; Altindağ, Cem; Özdemir, Erdi; Uyar, Yavuz

    2017-11-01

    To investigate the effect of dexpanthenol-vitamin A (Nazalnem) ointment applied to the surface of silastic splints with an airway immediately after nasal septal surgery on postoperative complaints and nasal mucosa function. The study enrolled 60 patients undergoing nasal septoplasty surgery. Group 1 (n = 30) received silastic splints with ointment containing dexpanthenol-vitamin A (Nazalnem), and Group 2 (n = 30), the control group, received silastic splints with vaseline. Of these patients, 2 patients from the Group 1 and 9 from the Group 2 were excluded.A thin layer of ointment was applied to the flat side of a silastic splint with an airway. The splints were removed on the second postoperative day. Patients were evaluated preoperatively and 1 and 2 weeks postoperatively using a visual analog scale and the Sino-Nasal Outcome test (SNOT-22). Mucociliary clearance (MCC) tests were performed at the same times. Visual analog scale for nasal crusting, nasal congestion, and foul odor was better in Group 1 than in Group 2 both at 1 week and at 2 weeks postoperatively (P < 0.05).The SNOT scores were significantly lower in Group 1 than in Group 2 at 1 week (P < 0.01), but did not differ at 2 weeks postoperatively (P > 0.05).Postoperatively, the MCC were insignificant between the groups and within the groups at 1 and 2 weeks (P > 0.05). Although Dexpanthenol-Vitamin A ointment had no direct effect on wound healing, it had significant effects on crusting, obstruction, and foul smell. However, silastic splints with dexpanthenol did not improve the MCC of the nose.

  15. 42 CFR 414.106 - Splints and casts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false Splints and casts. 414.106 Section 414.106 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM (CONTINUED) PAYMENT FOR PART B MEDICAL AND OTHER HEALTH SERVICES Fee Schedules for...

  16. 21 CFR 878.3900 - Inflatable extremity splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Inflatable extremity splint. 878.3900 Section 878.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3900 Inflatable extremity...

  17. 21 CFR 878.3900 - Inflatable extremity splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Inflatable extremity splint. 878.3900 Section 878.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3900 Inflatable extremity...

  18. 21 CFR 878.3900 - Inflatable extremity splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Inflatable extremity splint. 878.3900 Section 878.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3900 Inflatable extremity...

  19. 21 CFR 878.3900 - Inflatable extremity splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Inflatable extremity splint. 878.3900 Section 878.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3900 Inflatable extremity...

  20. 21 CFR 878.3900 - Inflatable extremity splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inflatable extremity splint. 878.3900 Section 878.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3900 Inflatable extremity...

  1. Customized dynamic splinting: orthoses that promote optimal function and recovery after radial nerve injury: a case report.

    PubMed

    McKee, Pat; Nguyen, Cecilia

    2007-01-01

    Radial nerve injury is a relatively common occurrence and recovery depends on the level of injury and extent of connective tissue damage. Orthoses (splints) are often provided to compensate for lost motor power. This article chronicles the recovery, over 27 months, of a 76-year-old woman who sustained a high radial nerve injury of her dominant arm during surgery for total shoulder replacement (Delta Reverse). Customized, low-profile dynamic splints, unlike any previously published design, were developed to address her goals for functional independence and the biological needs of the tissues. Dynamic power was provided to the wrist, fingers, and thumb by elastic cords and thin, flexible thermoplastic, without the need of an outrigger, thus avoiding the need for wire bending and cutting. At the outset, the splint was forearm-based and when wrist extension power was recovered, a hand-based splint was designed. Eventually, a circumferential hand-based thumb-stabilizing splint fulfilled most of the remaining orthotic requirements.

  2. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890... abduction splint is a device intended for medical purposes to stabilize the hips of a young child with...

  3. The prevention of shin splints in sports: a systematic review of literature.

    PubMed

    Thacker, Stephen B; Gilchrist, Julie; Stroup, Donna F; Kimsey, C Dexter

    2002-01-01

    To review the published and unpublished evidence regarding risk factors associated with shin splints, assess the effectiveness of prevention strategies, and offer evidence-based recommendations to coaches, athletes, and researchers. We searched electronic data bases without language restriction, identified citations from reference sections of research papers retrieved, contacted experts in the field, and searched the Cochrane Collaboration. Of the 199 citations identified, we emphasized results of the four reports that compared methods to prevent shin splints. We assessed the methodologic quality of these reports by using a standardized instrument. The use of shock-absorbent insoles, foam heel pads, heel cord stretching, alternative footwear, as well as graduated running programs among military recruits have undergone assessment in controlled trials. There is no strong support for any of these interventions, and each of the four controlled trials is limited methodologically. Median quality scores in these four studies ranged from 29 to 47, and serious flaws in study design, control of bias, and statistical methods were identified. Our review yielded little objective evidence to support widespread use of any existing interventions to prevent shin splints. The most encouraging evidence for effective prevention of shin splints involves the use of shock-absorbing insoles. However, serious flaws in study design and implementation constrain the work in this field thus far. A rigorously implemented research program is critically needed to address this common sports medicine problem.

  4. Analysis and comparison of wrist splint designs using the finite element method: Multi-material three-dimensional printing compared to typical existing practice with thermoplastics.

    PubMed

    Cazon, Aitor; Kelly, Sarah; Paterson, Abby M; Bibb, Richard J; Campbell, R Ian

    2017-09-01

    Rheumatoid arthritis is a chronic disease affecting the joints. Treatment can include immobilisation of the affected joint with a custom-fitting splint, which is typically fabricated by hand from low temperature thermoplastic, but the approach poses several limitations. This study focused on the evaluation, by finite element analysis, of additive manufacturing techniques for wrist splints in order to improve upon the typical splinting approach. An additive manufactured/3D printed splint, specifically designed to be built using Objet Connex multi-material technology and a virtual model of a typical splint, digitised from a real patient-specific splint using three-dimensional scanning, were modelled in computer-aided design software. Forty finite element analysis simulations were performed in flexion-extension and radial-ulnar wrist movements to compare the displacements and the stresses. Simulations have shown that for low severity loads, the additive manufacturing splint has 25%, 76% and 27% less displacement in the main loading direction than the typical splint in flexion, extension and radial, respectively, while ulnar values were 75% lower in the traditional splint. For higher severity loads, the flexion and extension movements resulted in deflections that were 24% and 60%, respectively, lower in the additive manufacturing splint. However, for higher severity loading, the radial defection values were very similar in both splints and ulnar movement deflection was higher in the additive manufacturing splint. A physical prototype of the additive manufacturing splint was also manufactured and was tested under normal conditions to validate the finite element analysis data. Results from static tests showed maximum displacements of 3.46, 0.97, 3.53 and 2.51 mm flexion, extension, radial and ulnar directions, respectively. According to these results, the present research argues that from a technical point of view, the additive manufacturing splint design stands at the

  5. Occlusion therapy of unilateral amblyopia with botulinum toxin induced ptosis.

    PubMed

    Halkiadakis, Ioannis; Iliaki, Olga; Kalyvianaki, Maria I; Tsilimbaris, Miltiadis K

    2007-01-01

    In order to evaluate the role of botulinum toxin induced ptosis as an occlusion method to treat unilateral deep strabismic amblyopia in two uncooperative children, we injected 0.2 ml of diluted botulinum toxin in the levator palpaebrae; low sedation was necessary in one of the two children. In both cases a marked ptosis was achieved, which lasted about four weeks and then gradually resolved completely. The visual acuity of the ablyopic eye increased in both children, making patching easy thereafter. One child developed amblyopia in the injected eye, which was handled successfully using part-time occlusion. No other side effects were noted. Whether this new method could be a simple, safe and effective alternative method of occlusion for the treatment of deep amblyopia in uncooperative children needs to be proven with a larger series of children.

  6. A population-based incidence of M2 strokes indicates potential expansion of large vessel occlusions amenable to endovascular therapy.

    PubMed

    Rai, Ansaar T; Domico, Jennifer R; Buseman, Chelsea; Tarabishy, Abdul R; Fulks, Daniel; Lucke-Wold, Noelle; Boo, SoHyun; Carpenter, Jeffrey S

    2018-06-01

    M2 occlusions may result in poor outcomes and potentially benefit from endovascular therapy. Data on the rate of M2 strokes is lacking. Patients with acute ischemic stroke discharged over a period of 3 years from a tertiary level hospital in the 'stroke belt' were evaluated for M2 occlusions on baseline vascular imaging. Regional and national incidence was calculated from discharge and multicounty data. There were 2739 ICD-9 based AIS discharges. M2 occlusions in 116 (4%, 95% CI 3.5% to 5%) patients constituted the second most common occlusion site. The median National Institute of Health Stroke Scale (NIHSS) score was 12 (IQR 5-18). Good outcomes were observed in 43% (95% CI 34% to 53%), poor outcomes in 57% (95% CI 47% to 66%), and death occurred in 27% (95% CI 19% to 37%) of patients. Receiver operating characteristics curves showed the NIHSS to be predictive of outcomes (area under the curve 0.829, 95% CI 0.745 to 0.913, p<0.0001). An NIHSS score ≥9 was the optimal cut-off point for predicting poor outcomes (sensitivity 85.7%, specificity 67.4%). 71 (61%) patients had an NIHSS score ≥9 and 45 (39%) an NIHSS score <9. The rate of good-outcome was 22.6% for NIHSS score ≥9 versus 78.4% for NIHSSscore <9 (OR=0.08, 95% CI 0.03 to 0.21, p<0.0001). Mortality was 42% for NIHSS score ≥9 versus 2.7% for NIHSS score <9 (OR=26, 95% CI 3.3 to 202, p<0.0001). Infarct volume was 57 (±55.7) cm 3 for NIHSS score ≥9 versus 30 (±34)cm 3 for NIHSS score <9 (p=0.003). IV recombinant tissue plasminogen activator (rtPA) administered in 28 (24%) patients did not affect outcomes. The rate of M2 occlusions was 7 (95% CI 5 to 9)/100 000 people/year (3%, 95% CI 2% to 4%), giving an incidence of 21 176 (95% CI 15 282 to 29 247)/year. Combined with M1, internal carotid artery terminus and basilar artery, this yields a 'large vessel occlusion (LVO)+M2' rate of 31 (95% CI 26 to 35)/100 000 people/year and a national incidence of 99 227 (95% CI 84 004 to 112 005

  7. Comparison of the effectiveness in pain reduction and pulmonary function between a rib splint constructed in the ER and a manufactured rib splint.

    PubMed

    Lee, Yoonje; Lee, Sang-Hyun; Kim, Changsun; Choi, Hyuk Joong

    2018-05-01

    In the treatment of patients with rib fractures (RFs), pain reduction is the most important consideration. Various studies have examined the effectiveness of treatments administered to RF patients, such as lidocaine patches, IV drugs, nerve blockers, and surgery. In this study, we evaluated the difference in the effectiveness in pain reduction between 2 groups of RF patients: 1 group who received a rib splint constructed in the ER (ER splint) and another group who received a Chrisofix Chest Orthosis (CCO) manufactured rib splint. A pilot study for a prospective randomized clinical trial was conducted to compare subjects using the CCO (Group A) with those using the ER splint (Group B) before and after the intervention. The primary outcome was difference in the level of pain based on the visual analogue scale (VAS) and the pulmonary function (PF) variables between before and after intervention in each group during forceful and resting respiration. A total of 24 subjects were enrolled in this study. The VAS results showed that the intervention was significantly effective in each group (before vs after: Group A resting: 8.50 ± 1.05 vs 4.17 ± 1.33, P < .001; Group A forceful: 9.83 ± 0.41 vs 7.17 ± 0.75, P < .001; Group B resting: 8.83 ± 1.60 vs 4.50 ± 1.38, P < .001; and Group B forceful: 9.67 ± 0.82 vs 7.33 ± 1.51, P = .003). The PF variables showed that the intervention was significantly effective in each group (before vs after: Group A, FVC: 2.74 ± 0.92 vs 3.35 ± 0.99, P < .001; FEV1: 2.16 ± 0.74 vs 2.57 ± 0.78, P = .001; PEF: 235.30 ± 43.06 vs 319.00 ± 51.58, P = .004; and Group B, FVC: 2.02 ± 0.49 vs 2.72 ± 0.62, P < .001; FEV1: 1.27 ± 0.25 vs 1.91 ± 0.37, P < .001; PEF: 216.67 ± 67.49 vs 300.33 ± 87.79, P = .003). Applying either the CCO or the ER splint to RF patients effectively reduced pain, and no significant differences

  8. Influence of bruxism on survival of porcelain laminate veneers

    PubMed Central

    Agustín-Panadero, Rubén; Fons-Font, Antonio; Román-Rodríguez, Juan L.; Solá-Ruíz, María F.

    2014-01-01

    Objectives: This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Material and Methods: Restorations were made in 70 patients, including 30 patients with some type of parafunctional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, fractures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Results: Analysis of the ceramic failures showed that of the 13 fractures and 29 debonding that were present in our study, 8 fractures and 22 debonding were related to the presence of bruxism. Conclusions: Porcelain laminate veneers are a predictable treatment option that provides excellent results, recognizing a higher risk of failure in patients with bruxism activity. The use of occlusal splints reduces the risk of fractures. Key words:Veneer, fracture, debonding, bruxism, occlusal splint. PMID:23986018

  9. Comparison of Early-period Results of Nasal Splint and Merocel Nasal Packs in Septoplasty

    PubMed Central

    Bingöl, Fatih; Budak, Ali; Şimşek, Eda; Kılıç, Korhan; Bingöl, Buket Özel

    2017-01-01

    Objective Several types of nasal packs are used postoperatively in septoplasty. In this study, we compared two commonly used nasal packing materials, the intranasal septal splint with airway and Merocel tampon, in terms of pain, bleeding, nasal obstruction, eating difficulties, discomfort in sleep, and pain and bleeding during removal of packing in the early period. Methods The study group included 60 patients undergoing septoplasty. Patients were divided into two groups (n=30 in each group). An intranasal splint with airway was used for the patients in the first group after septoplasty, while Merocel nasal packing was used for the second group. Patients were investigated in terms of seven different factors - pain, bleeding while the tampon was in place, nasal obstruction, eating difficulties, night sleep, pain during removal of the nasal packing, and bleeding after removal of packing. Results There was no statistically significant difference between the groups in terms of pain 24 hours after operation (p=0.05), while visual analog scale (VAS) scores for nasal obstruction, night sleep, eating difficulties, and pain during packing removal were lower in the nasal splint group with a statistically significant difference (p<0.05). There was no statistically significant difference between the groups in terms of postoperative bleeding (p=0.23). Significantly less bleeding occurred during removal of the packing in the nasal splint group (p<0.05). Conclusion Our study indicates that the nasal splint was more comfortable and effective in terms of causing lesser bleeding and pain during removal of packing. PMID:29392071

  10. Shin splints: painful to have and to treat.

    PubMed

    Story, Julie; Cymet, Tyler Childs

    2006-01-01

    When people overuse their legs they develop an uncomfortable awareness of these limbs manifested as a dull burning or aching. The cause is often clear to the person with the problem as a result of the often obvious relationship to overdoing an exercise or activity and the pain. "Shin splints" is the lay term; physicians use the term medial tibial stress syndrome. The pathophysiology that leads to this pain is unclear, although there are a number of competing theories. Differential diagnosis includes stress fractures and compartment syndromes. Bone tumors or lipomas can also cause similar pain to shin splints. Diagnosis can be made by history alone in a majority of cases, but if the diagnosis is unclear, an X-ray and magnetic resonance imaging should be considered. Treatment is still mostly supportive and symptom related. Rest is the most important aspect of treatment. Locally applied cold and anti-inflammatory medication have also been felt to be beneficial.

  11. Chronic osteomyelitis of the tibia in a runner: catastrophic consequences of shin splints.

    PubMed

    Hammad, Yunes Nadim; Johnson, Abigail; Norrish, Alan

    2018-03-01

    Medial tibial stress syndrome and chronic osteomyelitis are conditions that are traditionally thought to affect very different patient groups. We present a case of shin splints in a recreational long-distance runner, complicated by chronic osteomyelitis of the tibia. This is a unique case in which the microtrauma resulting from shin splints was implicated as an entry point for bacterial infection into the bone. Clinical evaluation and bone biopsy culture results indicated haematogenous spread of bacteria originating from the oral cavity. The patient required surgical resection of the affected bone and a prolonged course of intravenous antibiotic treatment. We illustrate that when shin splints show signs of acute inflammation with delayed recovery, the possibility of osteomyelitis should be kept in mind. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Part-time versus full-time occlusion therapy for treatment of amblyopia: A meta-analysis.

    PubMed

    Yazdani, Negareh; Sadeghi, Ramin; Momeni-Moghaddam, Hamed; Zarifmahmoudi, Leili; Ehsaei, Asieh; Barrett, Brendan T

    2017-06-01

    To compare full-time occlusion (FTO) and part-time occlusion (PTO) therapy in the treatment of amblyopia, with the secondary aim of evaluating the minimum number of hours of part-time patching required for maximal effect from occlusion. A literature search was performed in PubMed, Scopus, Science Direct, Ovid, Web of Science and Cochrane library. Methodological quality of the literature was evaluated according to the Oxford Center for Evidence Based Medicine and modified Newcastle-Ottawa scale. Statistical analyses were performed using Comprehensive Meta-Analysis (version 2, Biostat Inc., USA). The present meta-analysis included six studies [three randomized controlled trials (RCTs) and three non-RCTs]. Pooled standardized difference in the mean changes in the visual acuity was 0.337 [lower and upper limits: -0.009, 0.683] higher in the FTO as compared to the PTO group; however, this difference was not statistically significant ( P  = 0.056, Cochrane Q value = 20.4 ( P  = 0.001), I 2  = 75.49%). Egger's regression intercept was 5.46 ( P  = 0.04). The pooled standardized difference in means of visual acuity changes was 1.097 [lower and upper limits: 0.68, 1.513] higher in the FTO arm ( P  < 0.001), and 0.7 [lower and upper limits: 0.315, 1.085] higher in the PTO arm ( P  < 0.001) compared to PTO less than two hours. This meta-analysis shows no statistically significant difference between PTO and FTO in treatment of amblyopia. However, our results suggest that the minimum effective PTO duration, to observe maximal improvement in visual acuity is six hours per day.

  13. Arteriovenous Fistula Development After Posterior Compartment Fasciotomy to Treat Shin Splints.

    PubMed

    Marotta, J J; Richmond, J C

    1988-12-01

    In brief: This case report presents an unusual complication in a distance runner who was treated for the shin splint syndrome. Following release of the deep posterior fascial compartment, he had mild erythema and swelling in the region of his incision. He could not bear full weight on his left leg because of pain. An arteriogram obtained approximately six months later showed an arteriovenous fistula, which was subsequently treated with resection and neurolysis of the saphenous nerve. The patient improved but did not reach his previous level of athletic performance. Recommendations for preventing this complication are outlined, and the use of the term shin splints is discussed.

  14. Correlation between TMD and Cervical Spine Pain and Mobility: Is the Whole Body Balance TMJ Related?

    PubMed Central

    Walczyńska-Dragon, Karolina; Baron, Stefan; Nitecka-Buchta, Aleksandra; Tkacz, Ewaryst

    2014-01-01

    Temporomandibular dysfunction (TMD) is considered to be associated with imbalance of the whole body. This study aimed to evaluate the influence of TMD therapy on cervical spine range of movement (ROM) and reduction of spinal pain. The study group consisted of 60 patients with TMD, cervical spine pain, and limited cervical spine range of movements. Subjects were interviewed by a questionnaire about symptoms of TMD and neck pain and had also masticatory motor system physically examined (according to RDC-TMD) and analysed by JMA ultrasound device. The cervical spine motion was analysed using an MCS device. Subjects were randomly admitted to two groups, treated and control. Patients from the treated group were treated with an occlusal splint. Patients from control group were ordered to self-control parafunctional habits. Subsequent examinations were planned in both groups 3 weeks and 3 months after treatment was introduced. The results of tests performed 3 months after the beginning of occlusal splint therapy showed a significant improvement in TMJ function (P > 0.05), cervical spine ROM, and a reduction of spinal pain. The conclusion is that there is a significant association between TMD treatment and reduction of cervical spine pain, as far as improvement of cervical spine mobility. PMID:25050363

  15. Clinical feasibility and efficacy of using virtual surgical planning in bimaxillary orthognathic surgery without intermediate splint.

    PubMed

    Li, Yunfeng; Jiang, Yangmei; Zhang, Nan; Xu, Rui; Hu, Jing; Zhu, Songsong

    2015-03-01

    Computer-aided jaw surgery has been extensively studied recently. The purpose of this study was to determine the clinical feasibility of performing bimaxillary orthognathic surgery without intermediate splint using virtual surgical planning and rapid prototyping technology. Twelve consecutive patients who underwent bimaxillary orthognathic surgery were included. The presented treatment plan here mainly consists of 6 procedures: (1) data acquisition from computed tomography (CT) of the skull and laser scanning of the dentition; (2) reconstruction and fusion of a virtual skull model with accurate dentition; (3) virtual surgery simulation including osteotomy and movement and repositioning of bony segments; (4) final surgical splint fabrication (no intermediate splint) using computer-aided design and rapid prototyping technology; (5) transfer of the virtual surgical plan to the operating room; and (6) comparison of the actual surgical outcome to the virtual surgical plan. All procedures of the treatment were successfully performed on all 12 patients. In quantification of differences between simulated and actual postoperative outcome, we found that the mean linear difference was less than 1.8 mm, and the mean angular difference was less than 2.5 degrees in all evaluated patients. Results from this study suggested that it was feasible to perform bimaxillary orthognathic surgery without intermediate splint. Virtual surgical planning and the guiding splints facilitated the diagnosis, treatment planning, accurate osteotomy, and bony segments repositioning in orthognathic surgery.

  16. Randomised comparison of three tools for improving compliance with occlusion therapy: an educational cartoon story, a reward calendar, and an information leaflet for parents.

    PubMed

    Tjiam, A M; Holtslag, G; Van Minderhout, H M; Simonsz-Tóth, B; Vermeulen-Jong, M H L; Borsboom, G J J M; Loudon, S E; Simonsz, H J

    2013-01-01

    We previously demonstrated that compliance with occlusion therapy for amblyopia was improved by the use of an educational programme, especially in children of parents of foreign origin and who spoke Dutch poorly. The programme consisted of: (i) a cartoon story for amblyopic children that explained without words why they should patch, (ii) a calendar with reward stickers, and (iii) an information leaflet for parents. In the current study, we assessed the individual effect of each component on compliance. We recruited 120 3- to 6-year-old children who lived in a low socio-economic status (SES) area in The Hague and were starting occlusion therapy for the first time. They were randomised to receive one of the components (three intervention groups), or a picture to colour (control group). The randomisation was blinded for treating orthoptist and researcher. Compliance was measured electronically using the Occlusion Dose Monitor (ODM). Primary outcome was percentage of compliance (actual/prescribed occlusion time). Secondary outcome was absolute occlusion hours per day. Parental fluency in Dutch was rated on a five-point scale. Compliance could be measured electronically in 88 of the 120 children; in 32 others, it failed for various reasons. Parental fluency in Dutch was moderate or worse in 36.4 % (p = 0.327). Average compliance was 55 % standard deviation (SD) 40 (n = 18) in the control group, 89 % SD 25 in the group receiving the educational cartoon (n = 25, P = 0.002 compared with control group), 67 % SD 33 (n = 24, P = 0.301) in the reward-calendar group and 73 % SD 40 (n = 21, P = 0.119) in the parent-information-leaflet group. On average, children in the control group occluded 1:46 SD1:19 hours/day, 2:33 SD 1:18 hours/day in the group receiving the educational cartoon, 1:59 SD 1:13 hours/day in the reward-calendar group and 2:18 SD 1:13 hours/day in the parent-information-leaflet group. No child who received the cartoon story occluded less than 1 hour per day

  17. Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis.

    PubMed

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Batista, Victor Eduardo de Souza; Noritomi, Pedro Yoshito; Pellizzer, Duardo Piza

    2018-01-01

    The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.

  18. Management of Symphysis and Parasymphysis Mandibular Fractures in Children Treated with MacLennan Splint: Stability and Early Results

    PubMed Central

    Bhat, Manohar; Sharma, Anupama; Sharma, Rajesh

    2015-01-01

    ABSTRACT Objective: The aim of this study was to assess the safety and efficiency of MacLennan splint in symphysis and parasymphysis mandibular fractures in children. Study design: Six patients (four boys and two girls, mean age 3 years, range between 2 and 5 years) were operated on parasymphysis fractures of children. The mean follow-up time was 12 months. MacLennan splint was applied in these case upto 3 weeks. Results: Primary healing of the fractured mandible was observed in all patients. Postoperative complications were minor and transient. The outcome of the operation was not endangered. Adverse tissue reaction like infection, malocclusion, swelling and growth restrictions did not occur during observation period. Conclusion: MacLennan splint is having various advantages like faster mobilization and the avoidance of secondary removal operations. Based on this preliminary results MacLennan splints are safe and efficient in the treatment of pediatric mandible fracture. How to cite this article: Khairwa A, Bhat M, Sharma A, Sharma R. Management of Symphysis and Parasymphysis Mandibular Fractures in Children Treated with MacLennan Splint: Stability and Early Results. Int J Clin Pediatr Dent 2015;8(2):127-132. PMID:26379381

  19. Development and refinement of computer-assisted planning and execution system for use in face-jaw-teeth transplantation to improve skeletal and dento-occlusal outcomes.

    PubMed

    Hashemi, Sepehr; Armand, Mehran; Gordon, Chad R

    2016-10-01

    To describe the development and refinement of the computer-assisted planning and execution (CAPE) system for use in face-jaw-teeth transplants (FJTTs). Although successful, some maxillofacial transplants result in suboptimal hybrid occlusion and may require subsequent surgical orthognathic revisions. Unfortunately, the use of traditional dental casts and splints pose several compromising shortcomings in the context of FJTT and hybrid occlusion. Computer-assisted surgery may overcome these challenges. Therefore, the use of computer-assisted orthognathic techniques and functional planning may prevent the need for such revisions and improve facial-skeletal outcomes. A comprehensive CAPE system for use in FJTT was developed through a multicenter collaboration and refined using plastic models, live miniature swine surgery, and human cadaver models. The system marries preoperative surgical planning and intraoperative execution by allowing on-table navigation of the donor fragment relative to recipient cranium, and real-time reporting of patient's cephalometric measurements relative to a desired dental-skeletal outcome. FJTTs using live-animal and cadaveric models demonstrate the CAPE system to be accurate in navigation and beneficial in improving hybrid occlusion and other craniofacial outcomes. Future refinement of the CAPE system includes integration of more commonly performed orthognathic/maxillofacial procedures.

  20. Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.

    PubMed

    Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P

    2008-12-01

    The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p < 0.05). Sufficient vision penalization can be achieved to make occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.

  1. [Occlusion: current situation and prospect in view of holistic integrative medicine].

    PubMed

    Wang, M Q; Liu, X D

    2017-08-09

    The rise of holistic integrative medicine (HIM) is an inevitable consequence of modern medical development which emphasizes the change from specialization to integration of the most advanced medical knowledge. It does not mean a simple collection of the medical theories, but means the digestion of those theories for the clinical practical application. Because occlusal therapy is characterized as not only a high level of individualization, but also a relation to many stomatology and other disciplines, such as plastic surgery, orthopedics, neurosciences and psychology. It needs the HIM to guide the clinical practice. With undertaking occlusal therapy, to avoid the limitation due to the excessive specialized disciplines, and to provide effective treatment plans for abnormal occlusion induced diseases, it is necessary to develop the discipline of the holistic integrative stomatology.

  2. COMBINATION THERAPY OF INTRAVITREAL RANIBIZUMAB AND SUBTHRESHOLD MICROPULSE PHOTOCOAGULATION FOR MACULAR EDEMA SECONDARY TO BRANCH RETINAL VEIN OCCLUSION: 6-MONTH RESULT.

    PubMed

    Terashima, Hiroko; Hasebe, Hiruma; Okamoto, Fumiki; Matsuoka, Naoki; Sato, Yayoi; Fukuchi, Takeo

    2018-04-23

    To determine the efficacy of the combination therapy of intravitreal ranibizumab (IVR) and 577-nm yellow laser subthreshold micropulse laser photocoagulation (SMLP) for macular edema secondary to branch retinal vein occlusion cystoid macular edema. Retrospective, consecutive, case-control study. Forty-six eyes of 46 patients with treatment-naive branch retinal vein occlusion cystoid macular edema were enrolled. The IVR + SMLP group consisted of 22 patients who had undergone both SMLP and IVR. Intravitreal ranibizumab group consisted of 24 patients who had undergone IVR monotherapy. Intravitreal ranibizumab therapy was one initial injection and on a pro re nata in both groups, and SMLP was performed at 1 month after IVR in the IVR + SMLP group. Preoperatively and monthly, best-corrected visual acuity and central retinal thickness were evaluated using swept source optical coherence tomography. Best-corrected visual acuity and central retinal thickness significantly improved at 6 months in IVR + SMLP and IVR groups. Best-corrected visual acuity and central retinal thickness were not significantly different between the two groups at any time points. The number of IVR injections during initial 6 months in IVR group (2.3 ± 0.9) was significantly greater (P = 0.034) than that in IVR + SMLP group (1.9 ± 0.8). The combination therapy of IVR and SMLP can treat branch retinal vein occlusion cystoid macular edema effectively, by decreasing the frequency of IVR injections while maintaining good visual acuity.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  3. A pilot randomized clinical trial of intermittent occlusion therapy liquid crystal glasses versus traditional patching for treatment of moderate unilateral amblyopia.

    PubMed

    Wang, Jingyun; Neely, Daniel E; Galli, Jay; Schliesser, Joshua; Graves, April; Damarjian, Tina G; Kovarik, Jessica; Bowsher, James; Smith, Heather A; Donaldson, Dana; Haider, Kathryn M; Roberts, Gavin J; Sprunger, Derek T; Plager, David A

    2016-08-01

    To compare the effectiveness of intermittent occlusion therapy (IO therapy) using liquid crystal glasses and continuous occlusion therapy using traditional adhesive patches for treating amblyopia. Children 3-8 years of age with previously untreated, moderate, unilateral amblyopia (visual acuity of 20/40 to 20/100 in the amblyopic eye) were enrolled in this randomized controlled trial. Amblyopia was associated with strabismus, anisometropia, or both. All subjects had worn any optimal refractive correction for at least 12 weeks without improvement. Subjects were randomized into two treatment groups: a 4-hour IO therapy group with liquid crystal glasses (Amblyz), set at 30-second opaque/transparent intervals (occluded 50% of wear time), and a 2-hour continuous patching group (occluded 100% of wear time). For each patient, visual acuity was measured using ATS-HOTV before and after 12 weeks of treatment. Data from 34 patients were available for analysis. Amblyopic eye visual acuity improvement from baseline was 0.15 ± 0.12 logMAR (95% CI, 0.09-0.15) in the IO therapy group (n = 19) and 0.15 ± 0.11 logMAR (95% CI, 0.1-0.15) in the patching group (n = 15). In both groups improvement was significant, but the difference between groups was not (P = 0.73). No adverse effects were reported. In this pilot study, IO therapy with liquid crystal glasses is not inferior to adhesive patching and is a promising alternative treatment for children 3-8 years of age with moderate amblyopia. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  4. Effects of a resistance training program performed with an interocclusal splint for community-dwelling older adults: a randomized controlled trial

    PubMed Central

    Hirase, Tatsuya; Inokuchi, Shigeru; Matsusaka, Nobuou; Nakahara, Kazumi; Okita, Minoru

    2016-01-01

    [Purpose] To examine whether resistance training for elderly community-dwellers performed with an interocclusal splint resulted in greater lower extremity muscle strength and better balance than resistance training performed without an interocclusal splint. [Subjects and Methods] Eighty-eight elderly persons using Japanese community day centers were randomly divided into two groups: an intervention group (n=45), which performed resistance training with an interocclusal splint; and a control group (n=43), which performed resistance training without an interocclusal splint. The resistance training program comprised a 40-min session performed twice a week for 12 weeks. Outcome measures were the chair stand test (CST), timed up and go test (TUG), and one-leg standing test (OLST). Assessments were conducted before the intervention and every 2 weeks after the start of the intervention. [Results] There was a significant group × time interaction for the OLST, with the intervention group showing significant improvement from 8 to 12 weeks compared to the control group. For the CST and TUG, no significant differences were found between the two groups throughout the 12 weeks. [Conclusion] Resistance training with an interocclusal splint improved the balance ability of elderly community-dwellers more effectively than resistance training without an interocclusal splint. PMID:27313359

  5. Effects of a resistance training program performed with an interocclusal splint for community-dwelling older adults: a randomized controlled trial.

    PubMed

    Hirase, Tatsuya; Inokuchi, Shigeru; Matsusaka, Nobuou; Nakahara, Kazumi; Okita, Minoru

    2016-05-01

    [Purpose] To examine whether resistance training for elderly community-dwellers performed with an interocclusal splint resulted in greater lower extremity muscle strength and better balance than resistance training performed without an interocclusal splint. [Subjects and Methods] Eighty-eight elderly persons using Japanese community day centers were randomly divided into two groups: an intervention group (n=45), which performed resistance training with an interocclusal splint; and a control group (n=43), which performed resistance training without an interocclusal splint. The resistance training program comprised a 40-min session performed twice a week for 12 weeks. Outcome measures were the chair stand test (CST), timed up and go test (TUG), and one-leg standing test (OLST). Assessments were conducted before the intervention and every 2 weeks after the start of the intervention. [Results] There was a significant group × time interaction for the OLST, with the intervention group showing significant improvement from 8 to 12 weeks compared to the control group. For the CST and TUG, no significant differences were found between the two groups throughout the 12 weeks. [Conclusion] Resistance training with an interocclusal splint improved the balance ability of elderly community-dwellers more effectively than resistance training without an interocclusal splint.

  6. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  7. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  8. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  9. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  10. Medical therapy, percutaneous coronary intervention and prognosis in patients with chronic total occlusions.

    PubMed

    Ladwiniec, Andrew; Allgar, Victoria; Thackray, Simon; Alamgir, Farquad; Hoye, Angela

    2015-12-01

    There is little published data reporting outcomes for those found to have a chronic total coronary occlusion (CTO) that is electively treated medically versus those treated by percutaneous coronary intervention (PCI). We sought to compare long-term clinical outcomes between patients treated by PCI and elective medical therapy in a consecutive cohort of patients with an identified CTO. Patients found to have a CTO on angiography between January 2002 and December 2007 in a single tertiary centre were identified using a dedicated database. Those undergoing CTO PCI and elective medical therapy to the CTO were propensity matched to adjust for baseline clinical and angiographic differences. In total, 1957 patients were identified, a CTO was treated by PCI in 405 (20.7%) and medical therapy in 667 (34.1%), 885 (45.2%) patients underwent coronary artery bypass graft surgery. Of those treated by PCI or medical therapy, propensity score matching identified 294 pairs of patients, PCI was successful in 177 patients (60.2%). All-cause mortality at 5 years was 11.6% for CTO PCI and 16.7% for medical therapy HR 0.63 (0.40 to 1.00, p=0.052). The composite of 5-year death or myocardial infarction occurred in 13.9% of the CTO PCI group and 19.6% in the medical therapy group, HR 0.64 (0.42 to 0.99, p=0.043). Among the CTO PCI group, if the CTO was revascularised by any means during the study period, 5-year mortality was 10.6% compared with 18.3% in those not revascularised in the medical therapy group, HR 0.50 (0.28-0.88, p=0.016). Revascularisation, but not necessarily PCI of a CTO, is associated with improved long-term survival relative to medical therapy alone. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study

    PubMed Central

    Selvaraj, Sunantha; Dorairaj, Jayachandran; Mohan, Jayashree; Simon, Paul

    2016-01-01

    Introduction: An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. Objective: The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. Methodology: A mandibular reference model with four ADIN implants was done. Ten custom trays were fabricated using the light curable resin sheets. Medium body polyether impression material was used. These trays were randomly divided between the two groups, with five trays in each group. Impression techniques were divided into two groups namely: Group A: Direct impression technique with open tray impression copings splinted with autopolymerizing acrylic resin (GC pattern resin). Group B: Direct impression technique with open tray impression copings splinted with Pro-temp TM 4 (bis-GMA) syringable temporization material. Thus, final impressions were made. Total of 10 master casts were fabricated. Evaluation of casts using Dynascope-Vision Engineering, TESA microhite two- dimension and coordinate measuring machine were used. Results: Statistical comparisons were made using ANOVA test and post-hoc test. Same amount of deviation values obtained with resin splinted and bis-GMA splinted impression copings. Conclusion: The master cast obtained by both the splinting material exhibits no difference from the reference model. So bis-GMA can be used, which is easy to handle, less time consuming, less technique sensitive, rigid, and readily available material in clinics. PMID:27141167

  12. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    PubMed

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (< 60 years old) and elderly (60 years old or more) patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  13. Management of sleep-time masticatory muscle activity using stabilisation splints affects psychological stress.

    PubMed

    Takahashi, H; Masaki, C; Makino, M; Yoshida, M; Mukaibo, T; Kondo, Y; Nakamoto, T; Hosokawa, R

    2013-12-01

    To treat sleep bruxism (SB), symptomatic therapy using stabilisation splints (SS) is frequently used. However, their effects on psychological stress and sleep quality have not yet been examined fully. The objective of this study was to clarify the effects of SS use on psychological stress and sleep quality. The subjects (11 men, 12 women) were healthy volunteers. A crossover design was used. Sleep measurements were performed for three consecutive days or longer without (baseline) or with an SS or palatal splint (PS), and data for the final day were evaluated. We measured masseter muscle activity during sleep using portable electromyography to evaluate SB. Furthermore, to compare psychological stress before and after sleep, assessments were made based on STAI-JYZ and the measurement of salivary chromogranin A. To compare each parameter among the three groups (baseline, SS and PS), Friedman's and Dunn's tests were used. From the results of the baseline measurements, eight subjects were identified as high group and 15 as low group. Among the high group, a marked decrease in the number of bruxism events per hour and an increase in the difference in the total STAI Y-1 scores were observed in the SS group compared with those at baseline (P < 0·05). No significant difference was observed in sleep stages. SS use may be effective in reducing the number of SB events, while it may increase psychological stress levels, and SS use did not apparently influence sleep stages. © 2013 John Wiley & Sons Ltd.

  14. Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials.

    PubMed

    Buzayan, Muaiyed; Baig, Mirza Rustum; Yunus, Norsiah

    2013-01-01

    This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. A reference model with six internal-connection implant replicas placed in the completely edentulous mandibular arch and connected to multi-base abutments was fabricated from heat-curing acrylic resin. Forty impressions of the reference model were made, 20 each with polyether (PE) and polyvinylsiloxane (PVS) impression materials using the open tray technique. The PE and PVS groups were further subdivided into four subgroups of five each on the bases of splinting type: no splinting, bite registration PE, bite registration addition silicone, or autopolymerizing acrylic resin. The positional accuracy of the implant replica heads was measured on the poured casts using a coordinate measuring machine to assess linear differences in interimplant distances in all three axes. The collected data (linear and three-dimensional [3D] displacement values) were compared with the measurements calculated on the reference resin model and analyzed with nonparametric tests (Kruskal-Wallis and Mann-Whitney). No significant differences were found between the various splinting groups for both PE and PVS impression materials in terms of linear and 3D distortions. However, small but significant differences were found between the two impression materials (PVS, 91 μm; PE, 103 μm) in terms of 3D discrepancies, irrespective of the splinting technique employed. Casts obtained from both impression materials exhibited differences from the reference model. The impression material influenced impression inaccuracy more than the splinting material for multiple-unit abutment-level impressions.

  15. A prospective study of pain reduction and knee dysfunction comparing femoral skeletal traction and splinting in adult trauma patients.

    PubMed

    Bumpass, David B; Ricci, William M; McAndrew, Christopher M; Gardner, Michael J

    2015-02-01

    To determine if distal femoral traction pins result in knee dysfunction in patients with femoral or pelvic fracture, and to determine if skeletal traction relieves pain more effectively than splinting for femoral shaft fractures. Prospective cohort trial. Level I urban trauma center. One hundred twenty adult patients with femoral shaft, acetabular, and unstable pelvic fractures. Patients with femoral shaft fractures were placed into distal femoral skeletal traction or a long-leg splint, based on an attending-specific protocol. Patients with pelvic or acetabular fractures with instability or intraarticular bone fragments were placed into skeletal traction. An initial Lysholm knee survey was administered to assess preinjury knee pain and function; the survey was repeated at 3- and 6-month follow-up visits. Also, a 10-point visual analog scale was used to document pain immediately before, during, and immediately after fracture immobilization with traction or splinting. Thirty-five patients (29%) were immobilized with a long-leg splint, and 85 (71%) were immobilized with a distal femoral traction pin. Eighty-four patients (70%) completed a 6-month follow-up. Lysholm scores decreased by a mean 9.3 points from preinjury baseline to 6 months postinjury in the entire cohort (P < 0.01); no significant differences were found between the splint and traction pin groups. During application of immobilization, visual analog scale pain scores were significantly lower in traction patients as compared with splinted patients (mean, 1.9 points less, P < 0.01). Traction pins caused no infections, neurovascular injuries, or iatrogenic fractures. Distal femoral skeletal traction does not result in detectable knee dysfunction at 6 months after insertion, and results in less pain during and after immobilization than long-leg splinting. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  16. Natural teeth-retained splint based on a patient-specific 3D-printed mandible used for implant surgery and vestibuloplasty

    PubMed Central

    Xing, Helin; Wu, Jinshuang; Zhou, Lei; Yang, Sefei

    2017-01-01

    Abstract Rationale: With respect to improving the quality of oral rehabilitation, the management of keratinized mucosa is as important as bone condition for implant success. To enhance this management, a natural teeth-retained splint based on a patient-specific 3-dimensional (3D) printed mandible was used in vestibuloplasty to provide sufficient keratinized mucosa around dental implants to support long-term implant maintenance. Patient concerns: A 28-year-old male patient had a fracture of the anterior andible 1 year ago, and the fracture was treated with titanium. Diagnoses: The patient had lost mandibular incisors on both the sides and had a shallow vestibule and little keratinized mucosa. Interventions: In the first-stage implant surgery, 2 implants were inserted and the titanium fracture fixation plates and screws were removed at the same time. During second-stage implant surgery, vestibuloplasty was performed, and the natural teeth-retained splint was applied. The splint was made based upon a patient-specific 3D-printed mandible. At 30-day follow-up, the splint was modified and reset. The modified splint was removed after an additional 60 days, and the patient received prosthetic treatment. Outcomes: After prosthetic treatment, successful oral rehabilitation was achieved. Within 1 year and 3 years after implant prosthesis finished, the patient exhibited a good quantity of keratinized gingiva. Lessons subsections: The proposed splint is a simple and time-effective technique for correcting soft tissue defects in implant dentistry that ensures a good quantity of keratinized mucosa. PMID:29310359

  17. Coronary Intervention for Persistent Occlusion after Myocardial Infarction

    PubMed Central

    Hochman, Judith S.; Lamas, Gervasio A.; Buller, Christopher E.; Dzavik, Vladimir; Reynolds, Harmony R.; Abramsky, Staci J.; Forman, Sandra; Ruzyllo, Witold; Maggioni, Aldo P.; White, Harvey; Sadowski, Zygmunt; Carvalho, Antonio C.; Rankin, Jamie M.; Renkin, Jean P.; Steg, P. Gabriel; Mascette, Alice M.; Sopko, George; Pfisterer, Matthias E.; Leor, Jonathan; Fridrich, Viliam; Mark, Daniel B.; Knatterud, Genell L.

    2007-01-01

    BACKGROUND It is unclear whether stable, high-risk patients with persistent total occlusion of the infarct-related coronary artery identified after the currently accepted period for myocardial salvage has passed should undergo percutaneous coronary intervention (PCI) in addition to receiving optimal medical therapy to reduce the risk of subsequent events. METHODS We conducted a randomized study involving 2166 stable patients who had total occlusion of the infarct-related artery 3 to 28 days after myocardial infarction and who met a high-risk criterion (an ejection fraction of <50% or proximal occlusion). Of these patients, 1082 were assigned to routine PCI and stenting with optimal medical therapy, and 1084 were assigned to optimal medical therapy alone. The primary end point was a composite of death, myocardial reinfarction, or New York Heart Association (NYHA) class IV heart failure. RESULTS The 4-year cumulative primary event rate was 17.2% in the PCI group and 15.6% in the medical therapy group (hazard ratio for death, reinfarction, or heart failure in the PCI group as compared with the medical therapy group, 1.16; 95% confidence interval [CI], 0.92 to 1.45; P = 0.20). Rates of myocardial reinfarction (fatal and nonfatal) were 7.0% and 5.3% in the two groups, respectively (hazard ratio, 1.36; 95% CI, 0.92 to 2.00; P = 0.13). Rates of nonfatal reinfarction were 6.9% and 5.0%, respectively (hazard ratio, 1.44; 95% CI, 0.96 to 2.16; P = 0.08); only six reinfarctions (0.6%) were related to assigned PCI procedures. Rates of NYHA class IV heart failure (4.4% vs. 4.5%) and death (9.1% vs. 9.4%) were similar. There was no interaction between treatment effect and any subgroup variable (age, sex, race or ethnic group, infarct-related artery, ejection fraction, diabetes, Killip class, and the time from myocardial infarction to randomization). CONCLUSIONS PCI did not reduce the occurrence of death, reinfarction, or heart failure, and there was a trend toward excess

  18. Moist exposed therapy: an effective and valid alternative to occlusive dressings for postlaser resurfacing wound care.

    PubMed

    Atiyeh, Bishara S; Dham, Ruwayda; Costagliola, Michel; Al-Amm, Christian A; Belhaouari, Lakhdar

    2004-01-01

    Laser resurfacing has now become an accepted and important component of facial rejuvenation. With the introduction of computerized scanning systems, the actual laser resurfacing technique has been greatly simplified; however, the final outcome still depends to a large extent on the efficiency of the postlaser wound care in promoting wound healing and preventing early and late complications. It has been repeatedly confirmed that a moist environment is the single most important external factor affecting the rate of re-epithelialization. Occlusive moisture-retentive dressings, however, are difficult to apply and maintain in position and may as well be complicated by serious infections. Moist exposed burn ointment has been shown to maintain adequate moisture for optimal healing by frequent ointment application without the need for a secondary overlying dressing. It would be ideal for postoperative laser care. Twenty-eight consecutive patients treated with coherent ultrapulse CO2 laser in Toulouse, France, were included in the trial. Moisture-retentive ointment was applied over the treated areas every 4 to 6 hours. Healing was assessed clinically and with repeated transepidermal water loss measurements. Swab cultures were taken, and pain was evaluated with a visual analog scale. Colorimetric analysis of pictures taken was statistically compared with picture analysis of 20 patients treated earlier with an occlusive dressing. Uneventful timely healing occurred in all patients with minimal pain and discomfort. Healing with moist exposed therapy resulted in faster recovery of cutaneous erythema, as evidenced by colorometry. Moist exposed burn ointment application can be safely considered a good and valid alternative to occlusive dressings for postoperative laser care.

  19. [Cilioretinal artery occlusion and central retinal vein occlusion complicating hyperhomocysteinemia: a case report].

    PubMed

    Berkani, Z; Kitouni, Y; Belhadj, A; Sifi, K; Abbadi, N; Bellatrache, C; Hartani, D; Kherroubi, R

    2013-09-01

    Hyperhomocysteinemia is known to be a risk factor in both retinal artery and retinal vein occlusions. We report the case of a young patient with combined occlusion of the cilioretinal artery and the central retinal vein due to hyperhomocysteinemia. A 23-year-old patient without significant medical history, presented for sudden, painless visual loss in the right eye. Ophthalmologic examination revealed best-corrected visual acuity of the right eye 8/10 P2, and 10/10 P2 on the left. Anterior segment exam was normal in both eyes, while the right fundus revealed white, ischemic edema, centered around a cilioretinal artery, sparing the fovea, with some hemorrhagic spots and disc edema. Fluorescein angiography confirmed delayed filling of the right cilioretinal artery and revealed a normal disc on the left. Two weeks later, the clinical picture had evolved into a right ischemic CRVO, confirmed by a second angiogram, with a decrease in visual acuity to 3/10. A work-up was performed, including: a full lipid profile, serum electrolytes, ESR, CRP, a complete blood count (leukocytes, platelets, hemoglobin were normal), a coagulation work-up (PT, PTT, protein C, protein S, antithrombin III, factor V Leiden were normal), ANCA, antiphospholipid antibodies and antinuclear antibodies were negative, and finally cardiology studies (cardiac echo, carotid Doppler) and neurology (brain MRI) were ordered and came back normal. Otherwise, plasma homocysteine was moderately high on two samples, at 18.3 μmol/L and 17.78 μmol/L. Thyroid and renal work-ups were ordered. Urgent PRP was performed, and vitamin therapy (vitB12, vitB6, folic acid) was instituted. The subsequent course was remarkable for recovery of visual acuity to 10/10, P2 with persistence of an inferior altitudinal central scotoma. MTHFR C677T polymorphism was negative. Retinal vascular occlusions (RVO) are serious events, which require investigation for underlying systemic disease, which can be life-threatening. The clinical

  20. Effect of endovascular reperfusion in relation to site of arterial occlusion.

    PubMed

    Lemmens, Robin; Hamilton, Scott A; Liebeskind, David S; Tomsick, Tom A; Demchuk, Andrew M; Nogueira, Raul G; Marks, Michael P; Jahan, Reza; Gralla, Jan; Yoo, Albert J; Yeatts, Sharon D; Palesch, Yuko Y; Saver, Jeffrey L; Pereira, Vitor M; Broderick, Joseph P; Albers, Gregory W; Lansberg, Maarten G

    2016-02-23

    To assess whether the association between reperfusion and improved clinical outcomes after stroke differs depending on the site of the arterial occlusive lesion (AOL). We pooled data from Solitaire With the Intention for Thrombectomy (SWIFT), Solitaire FR Thrombectomy for Acute Revascularisation (STAR), Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution Study 2 (DEFUSE 2), and Interventional Management of Stroke Trial (IMS III) to compare the strength of the associations between reperfusion and clinical outcomes in patients with internal carotid artery (ICA), proximal middle cerebral artery (MCA) (M1), and distal MCA (M2/3/4) occlusions. Among 710 included patients, the site of the AOL was the ICA in 161, the proximal MCA in 389, and the distal MCA in 160 patients (M2 = 131, M3 = 23, and M4 = 6). Reperfusion was associated with an increase in the rate of good functional outcome (modified Rankin Scale [mRS] score 0-2) in patients with ICA (odds ratio [OR] 3.5, 95% confidence interval [CI] 1.7-7.2) and proximal MCA occlusions (OR 6.2, 95% CI 3.8-10.2), but not in patients with distal MCA occlusions (OR 1.4, 95% CI 0.8-2.6). Among patients with M2 occlusions, a subset of the distal MCA cohort, reperfusion was associated with excellent functional outcome (mRS 0-1; OR 2.2, 95% CI 1.0-4.7). The association between endovascular reperfusion and better clinical outcomes is more profound in patients with ICA and proximal MCA occlusions compared to patients with distal MCA occlusions. Because there are limited data from randomized controlled trials on the effect of endovascular therapy in patients with distal MCA occlusions, these results underscore the need for inclusion of this subgroup in future endovascular therapy trials. © 2016 American Academy of Neurology.

  1. A Pilot Randomized Clinical Trial of Intermittent Occlusion Therapy Liquid Crystal Glasses versus Traditional Patching for Treatment of Moderate Unilateral Amblyopia

    PubMed Central

    Wang, Jingyun; Neely, Daniel E.; Galli, Jay; Schliesser, Joshua; Graves, April; Damarjian, Tina G.; Kovarik, Jessica; Bowsher, James; Smith, Heather A.; Donaldson, Dana; Haider, Kathryn M.; Roberts, Gavin J.; Sprunger, Derek T.; Plager, David A.

    2017-01-01

    INTRODUCTION This pilot study was designed to compare the effectiveness of intermittent occlusion therapy (IO-Therapy) using liquid crystal glasses versus continuous occlusion therapy using traditional adhesive patches for treating amblyopia. DESIGN A randomized controlled trial. Children 3–8 years of age with previously untreated, moderate, unilateral amblyopia (visual acuity of 20/40 to 20/100 in the amblyopic eye) were enrolled. Amblyopia was associated with strabismus, anisometropia, or both. All subjects had worn optimal refractive correction (if needed) for at least 12 weeks without improvement. Subjects were randomized into two treatment groups: a 4-hour IO-Therapy Group with liquid crystal glasses (Amblyz™), set at 30-second opaque/transparent intervals (occluded 50% of wear time) or a 2-hour continuous Patching Group (occluded 100% of wear time). For each patient, visual acuity was measured with the ATS-HOTV method before and after 12 weeks of treatment. RESULTS At the conclusion of the first 12 week-treatment interval, data from 34 patients were available for analysis. Amblyopic eye visual acuity improvement from baseline was 0.15±0.12 (95% CI=0.09 to 0.15) logMAR in the IO-Therapy Group (N=19) and 0.15±0.11 (95% CI=0.1 to 0.15) logMAR in the Patching Group (N=15). Improvements in both groups were significant. The difference between groups was not statistically significant (P=0.73). No adverse effects were reported. CONCLUSION In this pilot study, IO-Therapy with Amblyz liquid crystal glasses is not inferior to adhesive patching and is a promising alternative treatment for children 3–8 years of age with moderate amblyopia. A larger randomized clinical trial is needed to confirm results in future. PMID:27418249

  2. Effects of neoprene wrist/hand splints on handwriting for students with joint hypermobility syndrome: a single system design study.

    PubMed

    Frohlich, Lauren; Wesley, Alison; Wallen, Margaret; Bundy, Anita

    2012-08-01

    Pain associated with hypermobility of wrist and hand joints can contribute to decreased handwriting output. This study examined the effectiveness of a neoprene wrist/hand splint in reducing pain and increasing handwriting speed and endurance for students with joint hypermobility syndrome. Multiple baseline, single system design (SSD) methodology was used. Four ninth grade students with handwriting difficulties because of joint hypermobility syndrome participated in this study. Visual and statistical (two standard deviation band method) analyses indicated a significant decrease in handwriting speed when using the splint for three out of four participants. No significant change in pain or endurance was noted during intervention. There was a significant decrease in pain following withdrawal of the splint for three participants. Evidence from this study does not support use of this particular splint for decreasing pain and increasing handwriting speed and endurance for ninth grade students with joint hypermobility syndrome.

  3. Evaluation of aural manifestations in temporo-mandibular joint dysfunction.

    PubMed

    Sobhy, O A; Koutb, A R; Abdel-Baki, F A; Ali, T M; El Raffa, I Z; Khater, A H

    2004-08-01

    Thirty patients with temporo-mandibular joint dysfunction were selected to investigate the changes in otoacoustic emissions before and after conservative treatment of their temporo-mandibular joints. Pure tone audiometry, transient-evoked otoacoustic emissions (TEOAE), distortion-product otoacoustic emissions (DPOAE) as well as a tinnitus questionnaire were administered to all patients before and after therapy. Therapy was conservative in the form of counselling, physiotherapy, anti-inflammatory agents, muscle relaxants, and occlusal splints. Results indicated insignificant changes in the TEOAEs, whereas there were significant increases in distortion product levels at most of the frequency bands. These results were paralleled to subjective improvement of tinnitus.

  4. Evidence for an enduring ischaemic penumbra following central retinal artery occlusion, with implications for fibrinolytic therapy.

    PubMed

    McLeod, David; Beatty, Stephen

    2015-11-01

    The rationale behind hyperacute fibrinolytic therapy for cerebral and retinal arterial occlusion is to rescue ischaemic cells from irreversible damage through timely restitution of tissue perfusion. In cerebral stroke, an anoxic tissue compartment (the "infarct core") is surrounded by a hypoxic compartment (the "ischaemic penumbra"). The latter comprises electrically-silent neurons that undergo delayed apoptotic cell death within 1-6 h unless salvaged by arterial recanalisation. Establishment of an equivalent hypoxic compartment within the inner retina following central retinal artery occlusion (CRAO) isn't widely acknowledged. During experimental CRAO, electroretinography reveals 3 oxygenation-based tissue compartments (anoxic, hypoxic and normoxic) that contribute 32%, 27% and 41% respectively to the pre-occlusion b-wave amplitude. Thus, once the anoxia survival time (≈2 h) expires, the contribution from the infarcted posterior retina is irreversibly extinguished, but electrical activity continues in the normoxic periphery. Inbetween these compartments, an annular hypoxic zone (the "penumbra obscura") endures in a structurally-intact but functionally-impaired state until retinal reperfusion allows rapid recovery from electrical silence. Clinically, residual circulation of sufficient volume flow rate generates the heterogeneous fundus picture of "partial" CRAO. Persistent retinal venous hypoxaemia signifies maximal extraction of oxygen by an enduring "polar penumbra" that permeates or largely replaces the infarct core. On retinal reperfusion some days later, the retinal venous oxygen saturation reverts to normal and vision improves. Thus, penumbral inner retina, marginally oxygenated by the choroid or by residual circulation, isn't at risk of delayed apoptotic infarction (unlike hypoxic cerebral cortex). Emergency fibrinolytic intervention is inappropriate, therefore, once the duration of CRAO exceeds 2 h. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Tibial Stress Injuries: Decisive Diagnosis and Treatment of "Shin Splints."

    ERIC Educational Resources Information Center

    Couture, Christopher J.; Karlson, Kristine A.

    2002-01-01

    Tibial stress injuries, commonly called shin splints, often result when bone remodeling processes adopt inadequately to repetitive stress. Physicians who are caring for athletic patients must have a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are…

  6. Design of splints based on the NiTi alloy for the correction of joint deformities in the fingers

    PubMed Central

    2010-01-01

    Background The proximal interphalange joint (PIP) is fundamental for the functional nature of the hand. The contracture in flexion of the PIP, secondary to traumatisms or illnesses leads to an important functional loss. The use of correcting splints is the common procedure for treating this problem. Its functioning is based on the application of a small load and a prolonged stress which can be dynamic, static progressive or static serial. It is important that the therapist has a splint available which can release a constant and sufficient force to correct the contracture in flexion. Nowadays NiTi is commonly used in bio-engineering, due to its superelastical characteristics. The experience of the authors in the design of other devices based on the NiTi alloy, makes it possible to carry out a new design in this work - the production of a finger splint for the treatment of the contracture in flexion of the PIP joint. Methods Commercial orthosis have been characterized using a universal INSTRON 5565 machine. A computational simulation of the proposed design has been conducted, reproducing its performance and using a model "ad hoc" for the NiTi material. Once the parameters have been adjusted, the design is validated using the same type of test as those carried out on commercial orthosis. Results and Discussion For commercial splint the recovering force falls to excessively low values as the angle increases. Angle curves for different lengths and thicknesses of the proposed design have been obtained, with a practically constant recovering force value over a wide range of angles that vary between 30° and 150° in every case. Then the whole treatment is possible with only one splint, and without the need of progressive replacements as the joint recovers. Conclusions A new model of splint based on NiTi alloy has been designed, simulated and tested comparing its behaviour with two of the most regularly used splints. Its uses is recommended instead of other dynamic

  7. Interstitial pressure measurements in the anterior and posterior compartments in athletes with shin splints.

    PubMed

    D'Ambrosia, R D; Zelis, R F; Chuinard, R G; Wilmore, J

    1977-01-01

    We found no basis for increased intercompartmental pressure in either the anterior or posterior compartments as the cause of shin splints. The pain in all 14 of the patients studied was localized to the posterior medial border of the tibia at the origin of the posterior tibial muscle, and evidence of periostitis in this area was seen in two of our patients, suggesting the possible tearing away of the posterior tibial muscle from its origin. Shin splints is a lay term which has assumed medical diagnostic significance and should be removed from common usage by more accurately localizing the focus of pain.

  8. Intravenous thrombolysis and endovascular therapy for acute ischemic stroke with internal carotid artery occlusion: a systematic review of clinical outcomes.

    PubMed

    Mokin, Maxim; Kass-Hout, Tareq; Kass-Hout, Omar; Dumont, Travis M; Kan, Peter; Snyder, Kenneth V; Hopkins, L Nelson; Siddiqui, Adnan H; Levy, Elad I

    2012-09-01

    Strokes secondary to acute internal carotid artery (ICA) occlusion are associated with extremely poor prognosis. The best treatment approach to acute stroke in this setting is unknown. We sought to determine clinical outcomes in patients with acute ischemic stroke attributable to ICA occlusion treated with intravenous (IV) systemic thrombolysis or intra-arterial endovascular therapy. Using the PubMed database, we searched for studies that included patients with acute ischemic stroke attributable to ICA occlusion who received treatment with IV thrombolysis or intra-arterial endovascular interventions. Studies providing data on functional outcomes beyond 30 days and mortality and symptomatic intracerebral hemorrhage (sICH) rates were included in our analysis. We compared the proportions of patients with favorable functional outcomes, sICH, and mortality rates in the 2 treatment groups by calculating χ(2) and confidence intervals for odds ratios. We identified 28 studies with 385 patients in the IV thrombolysis group and 584 in the endovascular group. Rates of favorable outcomes and sICH were significantly higher in the endovascular group than the IV thrombolysis-only group (33.6% vs 24.9%, P=0.004 and 11.1% vs 4.9%, P=0.001, respectively). No significant difference in mortality rate was found between the groups (27.3% in the IV thrombolysis group vs 32.0% in the endovascular group; P=0.12). According to our systematic review, endovascular treatment of acute ICA occlusion results in improved clinical outcomes. A higher rate of sICH after endovascular treatment does not result in increased overall mortality rate.

  9. Can electromagnetic-navigated maxillary positioning replace occlusional splints in orthognathic surgery? A clinical pilot study.

    PubMed

    Berger, Moritz; Nova, Igor; Kallus, Sebastian; Ristow, Oliver; Freudlsperger, Christian; Eisenmann, Urs; Dickhaus, Hartmut; Engel, Michael; Hoffmann, Jürgen; Seeberger, Robin

    2017-10-01

    Because of the inaccuracy of intermaxillary splints in orthognathic surgery, intraoperative guidance via a real time navigation system might represent a suitable method for enhancing the precision of maxillary positioning. Therefore, in this clinical trial, maxillary repositioning after Le Fort I osteotomy was guided splintless by an electromagnetic navigation system. Conservatively planned maxillary reposition in each of 5 patients was transferred to a novel software module of the electromagnetic navigation system. Intraoperatively, after Le Fort I osteotomy, the software guided the maxilla to the targeted position. Accuracy was evaluated by pre- and postoperative cone beam computer tomography imaging (the vectorial distance of the incisal marker points was measured in three dimensions) and compared with that of a splint transposed control group. The repositioning of the maxilla guided by the electromagnetic navigation system was intuitive and simple to accomplish. The achieved maxillary position with a deviation of 0.7 mm on average to the planned position was equally accurate compared with that of the splint transposed control group of 0.5 mm (p > 0.05). The data of this clinical study display good accuracy for splintless electromagnetic-navigated maxillary positioning. Nevertheless, this method does not surpass the splint-encoded gold standard with regard to accuracy. Future investigations will be necessary to show the full potential of electromagnetic navigation in orthognathic surgery. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. 3D splint prototype system for applications in muscular rehab by transcutaneous electrical nerve stimulation (TENS)

    NASA Astrophysics Data System (ADS)

    Saldaña-Martínez, M. I.; Guzmán-González, J. V.; Barajas-González, O. G.; Guzman-Ramos, V.; García-Garza, A. K.; González-García, R. B.; García-Ramírez, M. A.

    2017-03-01

    It is quite common that patients with ligamentous ruptures, tendonitis, tenosynovitis or sprains are foreseen the use of ad hoc splints for a swift recovery. In this paper, we propose a rehabilitation split that is focused on upper-limb injuries. By considering that upper-limb patient shows a set of different characteristics, our proposal personalizes and prints the splint custom made though a digital model that is generated by a 3D commercial scanner. To fabricate the 3D scanned model the Stereolithography material (SLA) is considered due to the properties that this material offers. In order to complement the recovery process, an electronic system is implemented within the splint design. This system generates a set of pulses for a fix period of time that focuses mainly on a certain group of muscles to allow a fast recovery process known as Transcutaneous Electrical Nerve Stimulation Principle (TENS).

  11. Transcatheter vessel occlusion: angiographic results versus clinical success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, L.; Greenfield, A.J.; Waltman, A.C.

    1983-04-01

    A review was made of 219 transcatheter vessel occlusion procedures performed over a ten-year period for control of hemorrhage, tumor palliation, or blood supply redistribution prior to intra-arterial chemotherapy. Complete angiographic success was obtained in 85% of the procedures, with partial success in 8%; complete clinical success was achieved in 53% of patients, with partial success in 23%. the most satisfactory clinical results were obtained with hemorrhagic gastritis and pelvic trauma. Embolizations for duodenal ulcer hemorrhage and transhepatic variceal occlusion were the least clinically successful, although isobutyl-cyanoacrylate appeared to be a significant improvement in angiographic therapy for duodenal ulcer. Themore » overall complication rate was 13%, with one third of the complications clinically silent. These results indicate that transcatheter vessel occlusion is a relatively safe and effective method for control of hemorrhage or tumor infarction.« less

  12. Carpal Tunnel Syndrome: Effectiveness of Physical Therapy and Electrophysical Modalities. An Updated Systematic Review of Randomized Controlled Trials.

    PubMed

    Huisstede, Bionka M; Hoogvliet, Peter; Franke, Thierry P; Randsdorp, Manon S; Koes, Bart W

    2017-09-20

    To review scientific literature studying the effectiveness of physical therapy and electrophysical modalities for carpal tunnel syndrome (CTS). The Cochrane Library, PubMed, Embase, CINAHL, and Physiotherapy Evidence Database. Two reviewers independently applied the inclusion criteria to select potential eligible studies. Two reviewers independently extracted the data and assessed the methodologic quality using the Cochrane Risk of Bias Tool. A best-evidence synthesis was performed to summarize the results of the included studies (2 reviews and 22 randomized controlled trials [RCTs]). For physical therapy, moderate evidence was found for myofascial massage therapy versus ischemic compression on latent, or active, trigger points or low-level laser therapy in the short term. For several electrophysical modalities, moderate evidence was found in the short term (ultrasound vs placebo, ultrasound as single intervention vs other nonsurgical interventions, ultrasound vs corticosteroid injection plus a neutral wrist splint, local microwave hyperthermia vs placebo, iontophoresis vs phonophoresis, pulsed radiofrequency added to wrist splint, continuous vs pulsed vs placebo shortwave diathermy, and interferential current vs transcutaneous electrical nerve stimulation vs a night-only wrist splint). In the midterm, moderate evidence was found in favor of radial extracorporeal shockwave therapy (ESWT) added to a neutral wrist splint, in favor of ESWT versus ultrasound, or cryo-ultrasound, and in favor of ultrasound versus placebo. For all other interventions studied, only limited, conflicting, or no evidence was found. No RCTs investigating the long-term effects of physical therapy and electrophysical modalities were found. Because of heterogeneity in the treatment parameters used in the included RCTs, optimal treatment parameters could not be identified. Moderate evidence was found for several physical therapy and electrophysical modalities for CTS in the short term and midterm

  13. Hepatic veno-occlusive disease after hematopoietic stem cell transplantation: update on defibrotide and other current investigational therapies.

    PubMed

    Ho, V T; Revta, C; Richardson, P G

    2008-02-01

    Hepatic veno-occlusive disease (VOD), also known as sinusoidal obstruction syndrome (SOS), remains one of the most serious and common complications after myeloablative hematopoietic stem cell transplantation (HSCT). Clinical diagnosis of hepatic VOD is based on the clinical triad of (1) painful hepatomegaly, (2) hyperbilirubinemia and (3) unexplained fluid retention. While milder cases usually resolve spontaneously, severe VOD is associated with a grim prognosis. Defibrotide (DF), a polydisperse mixture of single-stranded oligonucleotide with antithrombotic and fibrinolytic effects on microvascular endothelium, has emerged as an effective and safe therapy for patients with severe VOD. Multiple studies, including a recent large international multicenter phase II clinical trial, have demonstrated 30-60% complete remission rates with DF, even among patients with severe VOD and multiorgan failure. This article will review our current understanding of hepatic VOD, and update the clinical trial experience with DF and other potential therapies for this feared transplant complication.

  14. Tibial stress injuries: decisive diagnosis and treatment of 'shin splints'.

    PubMed

    Couture, Christopher J; Karlson, Kristine A

    2002-06-01

    Tibial stress injuries, commonly called 'shin splints,' often result when bone remodeling processes adapt inadequately to repetitive stress. Physicians who care for athletic patients need a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are implications for appropriate diagnosis, management, and prevention.

  15. Microfluidics for investigating vaso-occlusions in sickle cell disease.

    PubMed

    Horton, Renita E

    2017-07-01

    SCD stems from amutation in the beta globin gene. Upon deoxygenation, hemoglobin polymerizes and triggers RBC remodeling. This phenomenon is central to SCD pathogenesis as individuals suffering from the disease are plagued by painful vaso-occlusive crises episodes. These episodes are the result of a combination of processes including inflammation, thrombosis, and blood cell adhesion to the vascular wall which leads to blockages within the vasculature termed vaso-occlusions. Vaso-occlusive episodes deprive tissues of oxygen and are a major contributor to SCD-related complications; unfortunately, the complex mechanisms that contribute to vaso-occlusions are not well understood. Vaso-occlusions can occur in post-capillary venules; hence, the microvasculature is a prime target for SCD therapies. Traditional in vitro systems poorly recapitulate architectural and dynamic flow properties of in vivo systems. However, microfluidic devices can capture features of the native vasculature such as cellular composition, flow, geometry, and ECM presentation. This review, although not comprehensive, highlights microfluidic approaches that aim to improve our current understanding of the pathophysiological mechanisms surrounding SCD. Microfluidic platforms can aid in identifying factors that may contribute to disease severity and can serve as suitable test beds for novel treatment strategies which may improve patient outcomes. © 2017 John Wiley & Sons Ltd.

  16. A new approach of splint-less orthognathic surgery using a personalized orthognathic surgical guide system: A preliminary study

    PubMed Central

    Li, B.; Shen, S.; Jiang, W.; Li, J.; Jiang, T.; Xia, J. J.; Shen, S. G.; Wang, X.

    2017-01-01

    The purpose of this study was to evaluate a personalized orthognathic surgical guide (POSG) system for bimaxillary surgery without the use of surgical splint. Ten patients with dentofacial deformities were enrolled. Surgeries were planned with the computer-aided surgical simulation method. The POSG system was designed for both maxillary and mandibular surgery. Each consisted of cutting guides and three-dimensionally (3D) printed custom titanium plates to guide the osteotomy and repositioning the bony segments without the use of the surgical splints. Finally, the outcome evaluation was completed by comparing planned outcomes with postoperative outcomes. All operations were successfully completed using the POSG system. The largest root-mean-square deviations were 0.74 mm and 1.93° for the maxillary dental arch, 1.10 mm and 2.82° for the mandibular arch, 0.83 mm and 2.59° for the mandibular body, and 0.98 mm and 2.45° for the proximal segments. The results of the study indicated that our POSG system is capable of accurately and effectively transferring the surgical plan without the use of surgical splint. A significant advantage is that the repositioning of the bony segments is independent to the mandibular autorotation, thus eliminates the potential problems associated with the surgical splint. PMID:28552440

  17. Patients' and sleeping partners' experience of treatment for sleep-related breathing disorders with a mandibular repositioning splint.

    PubMed

    Bates, C J; McDonald, J P

    2006-01-28

    To determine in detail the complications associated with the use of mandibular repositioning splints (MRS) to treat sleep-related breathing disorders. This prospective cross-sectional cohort study audits the management with mandibular repositioning splints of 121 patients suffering from sleep-related breathing disorders. Investigation of patients' and sleeping partners' perspectives on treatment was undertaken with the use of a questionnaire based study. Sixty-eight per cent of respondents reported that they were compliant with treatment; various side effects were reported of which excess salivation was the most common. Investigation of sleeping partners' perspectives revealed that 70% felt that their partners' snoring was improved and 47% felt that their partner's breathing pauses during sleep were reduced. Sixty-four per cent of the sleeping partners also reported that their own sleep pattern had improved since their partner's treatment. Mandibular repositioning splints used in the manner described by this paper are demonstrated to have a good compliance rate, provide successful treatment and exhibit only minor, reversible side effects.

  18. Retinal vein occlusion: current treatment.

    PubMed

    Lattanzio, Rosangela; Torres Gimeno, Ana; Battaglia Parodi, Maurizio; Bandello, Francesco

    2011-01-01

    Retinal vein occlusion (RVO) is a pathology noted for more than 150 years. Although a lot has been written on the matter, it is still a frequent condition with multifactorial etiopathogenesis with many unclear aspects. The RVO pathogenesis has varied systemic and local implications that make it difficult to elaborate treatment guidelines. The management of the patient with RVO is very complex and a multidisciplinary approach is required in order to identify and correct the associated risk factors. Laser therapy remains the gold standard in RVO, but only modest functional improvement has been shown in branch retinal occlusion forms. Multicenter studies of intravitreal drugs present them as an option to combine with laser. Anti-vascular endothelial growth factor, corticosteroids and sustained-release implants are the future weapons to stop disease progression and get a better visual outcome. Consequently, it is useful to clarify some aspects of the pathology that allow a better patient management. Copyright © 2010 S. Karger AG, Basel.

  19. Stress Distribution in Splinted and Unsplinted Implant-Supported Maxillary Overdentures: A 3D Finite Element Analysis.

    PubMed

    Geramy, Allahyar; Habibzadeh, Sareh

    2018-02-01

    This study was accomplished to assess the biomechanical state of splinting in implant-supported maxillary overdentures. Two models of maxillary overdentures were designed in SolidWorks 2011. The first model included 4 separate implants and ball abutments, whereas the second one included 4 splinted implants connected with a bar. Evaluation was performed in ANSYS Workbench software with 200 N load applied at the molar-premolar region, bilaterally. The maximum equivalent stress and strain (von Mises) was recorded and analyzed along a path between the implants in the crestal bone and the prosthetic attachments. First model presented higher values of strain in prosthetic attachment and higher values of von Mises stress in crestal bone. The second model presented higher stress concentration in the gingival tissue of premolar area (near the bar), whereas the peak stress values were reported within the most distal part of the soft tissue support of the prosthesis in the first model (unsplinted). Splinting maxillary overdentures implants is associated with significant lower stress levels in the surrounding bone tissue.

  20. Occlusion therapy in amblyopia: an experience from Hong Kong.

    PubMed

    Tang, Emily W H; Li, Brian C Y; Yeung, Ian Y L; Li, Kenneth K W

    2014-02-01

    OBJECTIVES. To review the results of patching for amblyopia management in Hong Kong. DESIGN. Retrospective case series. SETTING. Regional hospital, Hong Kong. PATIENTS. Records of all patients attending Paediatric Ophthalmology Clinic at United Christian Hospital, Hong Kong from 1 January 2009 to 31 March 2009 were retrospectively reviewed. Records of all children who underwent patching for amblyopia in the study period were evaluated. RESULTS. The mean age of 50 children (50 eyes) was 4 (standard deviation, 1; range, 2-7) years and mean pretreatment visual acuity was 0.35 (0.15; 0.02-0.63) [~20/60]. The values for mean, standard deviation, and range of treatment duration were 27, 16, 4-67 months respectively, and corresponding values for prescribed patching per day were 4, 1, 2-8 hours. The mean, standard deviation, and range of visual acuity at final post-treatment assessment were 0.66, 0.16, 0.1-1.0 (~20/30), respectively. The overall success rate (ie final visual acuity >0.7 or 20/30) was 62%. Children with moderate amblyopia (20/40-20/80) and severe amblyopia (20/100-20/400) had success rates of 74% and 55%, respectively. The mean visual acuity improvements for moderate and severely amblyopic children were 2.3 lines and 5.8 lines, respectively. The mean, standard deviation, and range of patching prescriptions for moderate and severely amblyopic children were 5, 1, 2-7 hours and 5, 1, 3-6 hours, respectively. Recurrence ensued in 7% of the children with moderate amblyopia and 46% of those with severe amblyopia. Reported compliance was good (>75% of the time) in 68% of the children. CONCLUSION. Occlusion therapy is the mainstay of treatment in Hong Kong. The overall success rate was comparable to that achieved in the Amblyopia Treatment Study. Recurrence was more common in patients with severe amblyopia, for whom maintenance therapy may reduce the risk of recurrence. The duration of treatment was much longer in our locality than in western countries. Reported

  1. Is there a benefit of using an arbitrary facebow for the fabrication of a stabilization appliance?

    PubMed

    Shodadai, S P; Türp, J C; Gerds, T; Strub, J R

    2001-01-01

    The aim of this clinical study was to evaluate if an arbitrary facebow registration and transfer provides significant advantages for the fabrication of an occlusal appliance in comparison with the omission of such a procedure. For 20 fully dentate adult patients diagnosed with bruxism, two Michigan occlusal splints were constructed. One of the two upper dental casts was transferred to the articulator with an arbitrary earpiece facebow; the other maxillary cast was mounted arbitrarily using a flat occlusal plane indicator. Upon splint delivery, the number of intraoral occlusal contacts and the time needed for chairside occlusal adjustment were recorded. The number of occlusal contacts on the appliance fabricated with or without facebow was similar in most cases both in the articulator and in the mouth. The one-sided Wilcoxon rank sum test showed with high probability that the use of an arbitrary facebow does not yield a clinically relevant improvement with regard to the number of occlusal contacts or the chairside adjustment time. From this pilot study, it appears that for the fabrication of an occlusal appliance, registration and transfer with an arbitrary earpiece facebow does not yield clinically relevant benefits. Of course, this conclusion cannot be transferred to other facebows and is restricted to the levels of clinical relevance defined in the study.

  2. The relationship of heel contact in ascent and descent from jumps to the incidence of shin splints in ballet dancers.

    PubMed

    Gans, A

    1985-08-01

    I conducted a study to determine whether ballet dancers with a history of shin splints make heel contact on ascent and descent from jumps less often than dancers without this history. Sixteen dancers were filmed as they executed a sequence of jumps at two different speeds. Eight of the subjects had a history of shin-splint pain; eight had no such history. The film was viewed on a Super 8 movie projector. Heel contacts on ascent and descent from jumps were counted. Double heel strikes (heel rise between landing and pushing off) were also counted. A nonparametric t test showed no differences between the two groups in the number of contacts on ascent or descent. The dancers with a history of shin splints, however, demonstrated more double heel strikes (p = .02) than the other group. Clinically, this finding may represent a lack of control or a tight Achilles tendon or both. Further study is necessary to confirm these theories. For treatment and prevention of shin splints, a clinician must evaluate a dancer's jumping technique and then provide systematic training to develop the skin strength, flexibility, and coordination that make up control.

  3. Veno occlusive disease: Update on clinical management

    PubMed Central

    Senzolo, M; Germani, G; Cholongitas, E; Burra, P; Burroughs, AK

    2007-01-01

    Hepatic veno-occlusive disease is a clinical syndrome characterized by hepatomegaly, ascites, weight gain and jaundice, due to sinusoidal congestion which can be caused by alkaloid ingestion, but the most frequent cause is haematopoietic stem cell transplantation (STC) and is also seen after solid organ transplantation. The incidence of veno occlusive disease (VOD) after STC ranges from 0 to 70%, but is decreasing. Survival is good when VOD is a mild form, but when it is severe and associated with an increase of hepatic venous pressure gradient > 20 mmHg, and mortality is about 90%. Prevention remains the best therapeutic strategy, by using non-myeloablative conditioning regimens before STC. Prophylactic administration of ursodeoxycholic acid, being an antioxidant and antiapoptotic agent, can have some benefit in reducing overall mortality. Defibrotide, which has pro-fibrinolytic and antithrombotic properties, is the most effective therapy; decompression of the sinusoids by a transjugular intrahepatic portosystemic shunt (TIPS) can be tried, especially to treat VOD after liver transplantation and when multiorgan failure (MOF) is not present. Liver transplantation can be the last option, but can not be considered a standard rescue therapy, because usually the concomitant presence of multiorgan failure contraindicates this procedure. PMID:17663504

  4. The specific scintigraphic pattern of "shin splints in the lower leg": concise communication.

    PubMed

    Holder, L E; Michael, R H

    1984-08-01

    The clinical entity, "shin splints," is now being recognized, and more specifically characterized by the findings of exercise-induced pain and tenderness to palpation along the posterior medial border of the tibia. In this prospective study, ten patients with this syndrome were evaluated using three-phase bone scintigrams, and a specific scintigraphic pattern was determined. Radionuclide angiograms and blood-pool images were all normal. On delayed images, tibial lesions involved the posterior cortex, were longitudinally oriented, were long, involving one third of the length of the bone, and often showed varying tracer uptake along that length. Obtaining both lateral and medial views was crucial. The location of activity suggested that this entity is related to the soleus muscle. These scintigraphic findings can be used to differentiate shin splints from stress fractures or other conditions causing pain in the lower leg in athletes.

  5. Distal Radius Fractures Do Not Displace following Splint or Cast Removal in the Acute, Postreduction Period: A Prospective, Observational Study.

    PubMed

    Foster, Brock D; Sivasundaram, Lakshmanan; Heckmann, Nathanael; Pannell, William C; Alluri, Ram K; Ghiassi, Alidad

    2017-02-01

    Background  Displacement of distal radius fractures has been previously described in the literature; however, little is known about fracture displacement following splint or cast removal at the initial clinic visit following reduction and immobilization. Purpose  The purpose of this study was to evaluate risk factors for fracture displacement following splint or cast removal and physical examination in the acute postinjury period. Methods  All patients with a closed distal radius fracture who presented to our orthopedic hand clinic within 3 weeks of injury were prospectively enrolled in our study. Standard wrist radiographs were obtained prior to splint or cast removal. A second wrist series was obtained following physical exam and application of immobilization at the end of the clinic visit. Radiographic parameters for displacement were measured by two independent reviewers and included dorsal angulation, radial inclination, articular step-off, radial height, and ulnar variance. Displacement was assessed using predefined, radiographic criteria for displacement. Results  A total of 64 consecutive patients were enrolled over a period of 12 weeks. Of these, 37.5% were classified as operative according to American Academy of Orthopaedic Surgeons guidelines and 37.5% met LaFontaine instability criteria. For each fracture, none of the five measurements exceeded the predefined clinically or statistically significant criteria for displacement. Conclusion  Splint removal in the acute postinjury period did not result in distal radius fracture displacement. Clinicians should feel comfortable removing splints and examining underlying soft tissue in the acute setting for patients with distal radius fractures after closed reduction. Level of Evidence  Level II, prospective comparative study.

  6. Tendon-bone graft for tendinous mallet fingers following failed splinting.

    PubMed

    Wang, Le; Zhang, Xu; Liu, Ze; Huang, Xiuge; Zhu, Hongwei; Yu, Yadong

    2013-12-01

    To describe and assess a surgical technique for the treatment of tendinous mallet fingers after failed conservative treatment. From January 2010 to March 2012, 28 tendinous mallet fingers in 28 patients were treated. All patients had greater than 25° extensor lags after 6 to 8 weeks of splinting. Four patients had a second trial of splinting, which also failed. A tendon-bone graft, taken from the extensor carpi radialis brevis and the third metacarpal base, was used for reconstruction. The mean time between the injury and operation was 74 days. The mean preoperative extension lag was 34°. Five patients reported pain in the distal interphalangeal joint. At the final follow-up, patients rated the level of pain on the distal interphalangeal and wrist joints using a visual analog scale. Joint motion was graded with the Crawford criteria. Hand function was assessed with the Disabilities of the Arm, Shoulder, and Hand questionnaire. Patients reported on their satisfaction based on the Michigan Hand Outcomes Questionnaire. Bone healing was achieved in all patients at a mean of 5 weeks. Position of bone graft was maintained until bone healing was evident in all cases. At the mean follow-up period of 15 months, nail deformity was not noted. No patient reported pain on the distal interphalangeal joint or wrist. The mean residual extension lag of the distal interphalangeal joints was 4°. The results showed that 24 digits were excellent and 4 were good based on the Crawford criteria. The Disabilities of the Arm, Shoulder, and Hand scores averaged 1, and 27 patients were satisfied with appearance of the hand. One patient sometimes felt uncomfortable regarding the appearance. A tendon-bone graft is a useful and reliable technique for the treatment of tendinous mallet fingers after failed splinting. Therapeutic IV. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. The NTI-tss device for the therapy of bruxism, temporomandibular disorders, and headache – Where do we stand? A qualitative systematic review of the literature

    PubMed Central

    Stapelmann, Henrike; Türp, Jens C

    2008-01-01

    Background The NTI-tss device is an anterior bite stop, which, according to the manufacturer, is indicated for the prevention and treatment of bruxism, temporomandibular disorders (TMDs), tension-type headaches, and migraine. The aim of this systematic review was to appraise the currently available evidence regarding the efficacy and safety of the NTI-tss splint. Methods We performed a systematic search in nine electronic databases and in NTI-tss-associated websites (last update: December 31, 2007). The reference lists of all relevant articles were perused. Five levels of scientific quality were distinguished. Reporting quality of articles about randomized controlled trials (RCTs) was evaluated using the Jadad score. To identify adverse events, we searched in the identified publications and in the MAUDE database. Results Nine of 68 relevant publications reported about the results of five different RCTs. Two RCTs concentrated on electromyographic (EMG) investigations in patients with TMDs and concomitant bruxism (Baad-Hansen et al 2007, Jadad score: 4) or with bruxism alone (Kavaklı 2006, Jadad score: 2); in both studies, compared to an occlusal stabilization splint the NTI-tss device showed significant reduction of EMG activity. Two RCTs focused exclusively on TMD patients; in one trial (Magnusson et al 2004, Jadad score: 3), a stabilization appliance led to greater improvement than an NTI-tss device, while in the other study (Jokstad et al 2005, Jadad score: 5) no difference was found. In one RCT (Shankland 2002, Jadad score: 1), patients with tension-type headache or migraine responded more favorably to the NTI-tss splint than to a bleaching tray. NTI-tss-induced complications related predominantly to single teeth or to the occlusion. Conclusion Evidence from RCTs suggests that the NTI-tss device may be successfully used for the management of bruxism and TMDs. However, to avoid potential unwanted effects, it should be chosen only if certain a patient will be

  8. Effect and sustainability of part-time occlusion therapy for patients with anisometropic amblyopia aged > or =8 years.

    PubMed

    Hwang, D J; Kim, Y J; Lee, J Y

    2010-09-01

    To study the effect and long-term sustainability of part-time occlusion therapy for anisometropic amblyopia after 8 years of age. A total of 41 anisometropic amblyopes aged > or =8 years were analysed. In six patients, best-corrected visual acuity (BCVA) of amblyopic eye improved more than two lines within 2 weeks of full-time spectacle wear. The remaining patients were assigned to perform part-time patching during out-of-school hours. Long-term results were assessed in patients who were observed over 1 year after the end of the treatment. Among 35 patients, four dropped out, refusing further treatment, and one changed to atropine penalisation. The part-time patching schedule was completed in 30 patients. 90% of patients (27/30) complied well. Mean BCVA in the amblyopic eye improved significantly (p<0.001), and 96.7% of patients (29/30) achieved the final BCVA of 0.1 logMAR or better. In long-term results, 87% preserved the BCVA of 0.1 logMAR or better. None of four dropouts achieved the BCVA of 0.1 logMAR or better in long-term results even on the continuous spectacle wear. The part-time occlusion treatment in school-aged amblyopes, which had been carried out after school hours, was successful and the effect was sustained in most cases.

  9. Levodopa-carbidopa with occlusion in older children with amblyopia.

    PubMed

    Bhartiya, Prashant; Sharma, Pradeep; Biswas, Nihar R; Tandon, Radhika; Khokhar, Sudarshan K

    2002-12-01

    To study the role of levodopa-carbidopa in supplementing occlusion therapy in older children with strabismic or anisometropic amblyopia. A clinical study was performed on 40 amblyopic children (19 strabismic and 21 anisometropic), 6 to 18 years old (mean age, 10.9 years). They received an average dose of 1.86 mg/kg/day (1.33-2.36 mg/kg/day) of levodopa and carbidopa (4:1 ratio) or a placebo in 3 divided doses over a 4-week period, combined with full-time occlusion. The occlusion was continued for the study duration of 3 months. Early Treatment Diabetic Retinopathy Study visual acuity charts and Cambridge low-contrast gratings for contrast sensitivity (CS) were used to assess visual functions. Tolerance and compliance with occlusion and capsule consumption were assessed. Visual acuity of the nonamblyopic eye did not deteriorate during the study in either group. CS decreased by 22 units in the levodopa group and increased in the placebo group by 53 units at the first month. The CS in the levodopa group recovered later by the third month of follow-up. Both the levodopa and the placebo groups showed significant improvement in visual function in the amblyopic eye (P <.001). Overall changes in logarithm of minimum angle of resolution values and CS in the amblyopic eyes were similar in both groups (P >.05). Strabismic and anisometropic amblyopes did not behave differently. Drug tolerance, occlusion compliance, and capsule ingestion compliance were similar between the groups, with no significant side effects. Clinically, levodopa supplementation does not offer any advantage over occlusion alone. Moreover, the risk of occlusion amblyopia could increase with the use of drugs like levodopa that might affect the plasticity of the visual cortex.

  10. A case report on the remodelling technique for the earlobe using a soft splint.

    PubMed

    Vaiude, Partha N; Anthony, Edwin T; Syed, Mobin; Ilyas, Syed

    2008-01-01

    Correcting earlobe deformities often presents an aesthetic challenge to the surgeon. The described technique presents a simple, accurate and cost effective method of remodelling soft tissue defects of the earlobe using a soft splint.

  11. Immobilization in Neutral Rotation for a Glenohumeral Dislocation Using a Sling and Splint

    PubMed Central

    2008-01-01

    The purpose of this manuscript is to provide an expedient means of immobilizing a glenohumeral dislocation in neutral rotation. This technique for post-reduction immobilization of a glenohumeral dislocation is inexpensive and easy to fabricate. Anterior glenohumeral dislocations often involve an avulsion of the labrum from the glenoid rim. In contrast to immobilization in internal rotation, positioning the shoulder in 0-45° of external rotation approximates the labrum and glenoid rim. It is hypothesized that placing the shoulder in a more externally rotated position could allow for better healing and increased joint stability. This technique places the shoulder in neutral rotation, because 45° of external rotation is awkward and may interfere with certain activities of daily living. Structural aluminum malleable (SAM) splints are used as an alternative to a bolster sling. The SAM splints are lightweight, simply shaped, and easily stored. PMID:21509136

  12. Influence of bruxism on survival of porcelain laminate veneers.

    PubMed

    Granell-Ruíz, Maria; Agustín-Panadero, Rubén; Fons-Font, Antonio; Román-Rodríguez, Juan-Luis; Solá-Ruíz, María-Fernanda

    2014-09-01

    This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Restorations were made in 70 patients, including 30 patients with some type of parafunctional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, fractures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Analysis of the ceramic failures showed that of the 13 fractures and 29 debonding that were present in our study, 8 fractures and 22 debonding were related to the presence of bruxism. Porcelain laminate veneers are a predictable treatment option that provides excellent results, recognizing a higher risk of failure in patients with bruxism activity. The use of occlusal splints reduces the risk of fractures.

  13. Dynamics of Interocular Suppression in Amblyopic Children during Electronically Monitored Occlusion Therapy: First Insight.

    PubMed

    Kehrein, Stephan; Kohnen, Thomas; Fronius, Maria

    2016-06-01

    Interocular suppression is assumed to be the mechanism leading to impaired visual acuity, especially in strabismic amblyopia. Little is known about the dynamics of suppression during treatment. The aim of our study was to assess the development of the depth of suppression and its relation to changes in visual acuity during electronically monitored occlusion treatment. In a prospective pilot study, 15 amblyopes (8 with and 7 without strabismus) aged 5 to 16 years (mean 10.24 years) were examined before initiation of patching and then every 3 to 6 weeks for 4 months. To quantify suppression, a red filter ladder (Sbisa bar) was used, attenuating the image of the dominant eye until the patients reported a binocular perception (diplopia, rivalry, color mixture) or a change in eye dominance. Acuity was assessed with crowded Landolt rings. Daily occlusion was recorded using occlusion dose monitors. The depth of interocular suppression showed a biphasic change: it increased significantly during the first month (P=0.02), while visual acuity improved (mean 0.14 log units ±0.13; P<0.01). During the following 3 months, median suppression decreased back to the initial values. This reduction in suppression was more pronounced in anisometropic patients without strabismus than in amblyopes with strabismus. The average visual acuity steadily improved (P<0.01) during the 4 months of treatment. Mean recorded patching dose rate was 3.91 h/d. The correlation between mean daily occlusion and suppression changes was not statistically significant. This first insight into the functional changes during electronically monitored patching suggests a complex relationship between visual acuity and interocular suppression that seems to be influenced by the presence of strabismus. Knowledge of the dynamics of interocular suppression is crucial for enhancing the outcome of occlusion treatment and also for the evaluation of its future role compared to emerging dichoptic treatments.

  14. Improving prediction of recanalization in acute large-vessel occlusive stroke.

    PubMed

    Vanacker, P; Lambrou, D; Eskandari, A; Maeder, P; Meuli, R; Ntaios, G; Michel, P

    2014-06-01

    Recanalization in acute ischemic stroke with large-vessel occlusion is a potent indicator of good clinical outcome. To identify easily available clinical and radiologic variables predicting recanalization at various occlusion sites. All consecutive, acute stroke patients from the Acute STroke Registry and Analysis of Lausanne (2003-2011) who had a large-vessel occlusion on computed tomographic angiography (CTA) (< 12 h) were included. Recanalization status was assessed at 24 h (range: 12-48 h) with CTA, magnetic resonance angiography, or ultrasonography. Complete and partial recanalization (corresponding to the modified Treatment in Cerebral Ischemia scale 2-3) were grouped together. Patients were categorized according to occlusion site and treatment modality. Among 439 patients, 51% (224) showed complete or partial recanalization. In multivariate analysis, recanalization of any occlusion site was most strongly associated with endovascular treatment, including bridging therapy (odds ratio [OR] 7.1, 95% confidence interval [CI] 2.2-23.2), and less so with intravenous thrombolysis (OR 1.6, 95% CI 1.0-2.6) and recanalization treatments performed beyond guidelines (OR 2.6, 95% CI 1.2-5.7). Clot location (large vs. intermediate) and tandem pathology (the combination of intracranial occlusion and symptomatic extracranial stenosis) were other variables discriminating between recanalizers and non-recanalizers. For patients with intracranial occlusions, the variables significantly associated with recanalization after 24 h were: baseline National Institutes of Health Stroke Scale (NIHSS) (OR 1.04, 95% CI 1.02-1.1), Alberta Stroke Program Early CT Score (ASPECTS) on initial computed tomography (OR 1.2, 95% CI 1.1-1.3), and an altered level of consciousness (OR 0.2, 95% CI 0.1-0.5). Acute endovascular treatment is the single most important factor promoting recanalization in acute ischemic stroke. The presence of extracranial vessel stenosis or occlusion decreases

  15. Optimization of the static occlusion by "occlusal surface settling" in the Cerec 3D software.

    PubMed

    Späth, C; Kordass, B

    2006-04-01

    The adjustment of the static occlusion can be automated in computer-based systems. The Cerec 3D software makes it possible to take preformed occlusal surfaces from a database and adapt them to the antagonist. In this adaptation (settling), the CAD occlusal surface "settles" as whole or each cusp individually into the occlusal surface of the antagonist until stable occlusion is reached. Two occlusal surface shapes were compared: Vita Physiodens and Lee Culp. An index was formed from the number, quality, and position of the occlusal contacts for 35 model cases (25 molars, 10 premolars). With regard to the settling of the total occlusal surfaces, there were no differences between the two occlusal surface shapes. In "cusp settling" of the molars, Vita Physiodens performed significantly better. In the comparison of the 1st with the 3rd settling process, significant improvements occurred the 3rd time in many cases when settling individual cusps, but in clearly fewer cases in the settling process of the total occlusal surface. The Lee Culp tooth occlusion improved especially after the 3rd settling process of individual cusps. It is therefore expedient to combine both settling versions with one another.

  16. A randomized controlled trial of a leg orthosis versus traditional treatment for soldiers with shin splints: a pilot study.

    PubMed

    Johnston, Ember; Flynn, Timothy; Bean, Michael; Breton, Matthew; Scherer, Matthew; Dreitzler, Gail; Thomas, Dennis

    2006-01-01

    Diagnosis and management strategies for shin splints in active duty military populations closely resemble those in civilian athletic populations. There is a paucity of evidence supporting the use of many of these interventions. The purpose of this study was to present data on the Shin Saver orthosis as a treatment for shin splints in an active duty military population and to review current condition management. Twenty-five subjects diagnosed with shin splints by a U.S. Army physical therapist were randomly assigned to a shin orthosis treatment group or a control group. There was no significant difference between treatment and control groups in days to finish a 0.5-mile run pain free. Visual analog scales for pain at intake versus after 1 week of relative rest revealed no significant improvement in symptoms in either group. Current best-practice guidelines support a treatment program of rest, cryotherapy, and a graduated walk-to-run program.

  17. 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - our experience in 16 cases.

    PubMed

    Aboul-Hosn Centenero, Samir; Hernández-Alfaro, Federico

    2012-02-01

    The aim of this article is to determine the advantages of 3D planning in predicting postoperative results and manufacturing surgical splints using CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) technology in orthognathic surgery when the software program Simplant OMS 10.1 (Materialise(®), Leuven, Belgium) was used for the purpose of this study which was carried out on 16 patients. A conventional preoperative treatment plan was devised for each patient following our Centre's standard protocol, and surgical splints were manufactured. These splints were used as study controls. The preoperative treatment plans devised were then transferred to a 3D-virtual environment on a personal computer (PC). Surgery was simulated, the prediction of results on soft and hard tissue produced, and surgical splints manufactured using CAD/CAM technology. In the operating room, both types of surgical splints were compared and the degree of similitude in results obtained in three planes was calculated. The maxillary osteotomy line was taken as the point of reference. The level of concordance was used to compare the surgical splints. Three months after surgery a second set of 3D images were obtained and used to obtain linear and angular measurements on screen. Using the Intraclass Correlation Coefficient these postoperative measurements were compared with the measurements obtained when predicting postoperative results. Results showed that a high degree of correlation in 15 of the 16 cases. A high coefficient of correlation was obtained in the majority of predictions of results in hard tissue, although less precise results were obtained in measurements in soft tissue in the labial area. The study shows that the software program used in the study is reliable for 3D planning and for the manufacture of surgical splints using CAD/CAM technology. Nevertheless, further progress in the development of technologies for the acquisition of 3D images, new versions of software programs

  18. Occlusal changes secondary to temporomandibular joint conditions: a critical review and implications for clinical practice.

    PubMed

    Caldas, Waleska; Conti, Ana Cláudia de Castro Ferreira; Janson, Guilherme; Conti, Paulo César Rodrigues

    2016-01-01

    The aim of this article is to present the most commonly occlusal changes secondary to TMD. The clinical presentation of these conditions is discussed. Details regarding diagnosis, treatment, and follow-up of patients presenting TMD prior or during treatment are also presented. All plans for irreversible therapy should be preceded by a meticulous analysis of TMD signs and symptoms in such a way that patients are not submitted to irreversible treatment, based on an untrue occlusal relationship, secondary to articular and/or muscular disorders. When present, TMD symptoms must always be controlled to reestablish a "normal" occlusion and allow proper treatment strategy.

  19. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Nambiar, Ashwin, E-mail: uvashwin@gmail.com; Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Fivemore » arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.« less

  20. Long-Term Resolution of Severe Ankle Contractures Using Botulinum Toxin, Serial Casting, Splinting, and Motor Retraining.

    PubMed

    Leung, Joan; Stroud, Katarina

    2018-01-01

    Purpose: Serial casting for ankle contractures is traditionally performed in prone, a position that patients may not easily tolerate. Also, although serial casting is effective in correcting contracture, its effect dissipates quickly. This case report describes a procedure for performing casting for ankle contractures in a supine or sitting position. It also describes a process that enables the effect of serial casting to be maintained long term. Client Description: The client was an adult who had suffered traumatic brain injury and severe bilateral ankle contractures. Intervention: He received botulinum toxin and serial casting for his bilateral ankle contractures, one ankle at 8 months and the other at 13 months after the injury. He then underwent a programme of splinting and motor training. Measures and Outcome: The client gained more than 40° dorsiflexion for both ankles after receiving botulinum toxin injections and serial casting. The improvement in ankle range enabled him to progress to walking practice. Ankle splinting was gradually reduced. On discharge at 25 months post-injury, the ankle joint range was maintained. Implications: The use of botulinum toxin and serial casting, followed by an intensive programme of splinting and motor training, may be an option to consider for effective long-term resolution of severe contractures after acquired brain injury.

  1. Weighing the potential effectiveness of various treatments for sleep bruxism.

    PubMed

    Huynh, Nelly; Manzini, Christiane; Rompré, Pierre H; Lavigne, Gilles J

    2007-10-01

    Sleep bruxism may lead to a variety of problems, but its pathophysiology has not been completely elucidated. As such, there is no definitive treatment, but certain preventive measures and/or drugs may be used in acute cases, particularly those involving pain. This article is intended to guide clinician scientists to the treatment most appropriate for future clinical studies. To determine the best current treatment, 2 measures were used to compare the results of 10 clinical studies on sleep bruxism, 3 involving oral devices and 7 involving pharmacologic therapy. The first measure, the number needed to treat (NNT), allows several randomized clinical studies to be compared and a general conclusion to be drawn. The second measure, effect size, allows evaluation of the impact of treatment relative to a placebo using different studies of similar design. Taking into account the NNT, the effect size and the power of each study, it can be concluded that the following treatments reduce sleep bruxism: mandibular advancement device, clonidine and occlusal splint. However, the first 2 of these have been linked to adverse effects. The occlusal splint is therefore the treatment of choice, as it reduces grinding noise and protects the teeth from premature wear with no reported adverse effects. The NNT could not be calculated for an alternative pharmacologic treatment, short-term clonazepam therapy, which had a large effect size and reduced the average bruxism index. However, the risk of dependency limits its use over long periods. Assessment of efficacy and safety of the most promising treatments will require studies with larger sample sizes over longer periods.

  2. The impact of numeric and graphic displays of ST-segment deviation levels on cardiologists' decisions of reperfusion therapy for patients with acute coronary occlusion.

    PubMed

    Nimmermark, Magnus O; Wang, John J; Maynard, Charles; Cohen, Mauricio; Gilcrist, Ian; Heitner, John; Hudson, Michael; Palmeri, Sebastian; Wagner, Galen S; Pahlm, Olle

    2011-01-01

    The study purpose is to determine whether numeric and/or graphic ST measurements added to the display of the 12-lead electrocardiogram (ECG) would influence cardiologists' decision to provide myocardial reperfusion therapy. Twenty ECGs with borderline ST-segment deviation during elective percutaneous coronary intervention and 10 controls before balloon inflation were included. Only 5 of the 20 ECGs during coronary balloon occlusion met the 2007 American Heart Association guidelines for ST-elevation myocardial infarction (STEMI). Fifteen cardiologists read 4 sets of these ECGs as the basis for a "yes/no" reperfusion therapy decision. Sets 1 and 4 were the same 12-lead ECGs alone. Set 2 also included numeric ST-segment measurements, and set 3 included both numeric and graphically displayed ST measurements ("ST Maps"). The mean (range) positive reperfusion decisions were 10.6 (2-15), 11.4 (1-19), 9.7 (2-14), and 10.7 (1-15) for sets 1 to 4, respectively. The accuracies of the observers for the 5 STEMI ECGs were 67%, 69%, and 77% for the standard format, the ST numeric format, and the ST graphic format, respectively. The improved detection rate (77% vs 67%) with addition of both numeric and graphic displays did achieve statistical significance (P < .025). The corresponding specificities for the 10 control ECGs were 85%, 79%, and 89%, respectively. In conclusion, a wide variation of reperfusion decisions was observed among clinical cardiologists, and their decisions were not altered by adding ST deviation measurements in numeric and/or graphic displays. Acute coronary occlusion detection rate was low for ECGs meeting STEMI criteria, and this was improved by adding ST-segment measurements in numeric and graphic forms. These results merit further study of the clinical value of this technique for improved acute coronary occlusion treatment decision support. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. A Comparison of Cervical Spine Motion After Immobilization With a Traditional Spine Board and Full-Body Vacuum-Mattress Splint.

    PubMed

    Etier, Brian E; Norte, Grant E; Gleason, Megan M; Richter, Dustin L; Pugh, Kelli F; Thomson, Keith B; Slater, Lindsay V; Hart, Joe M; Brockmeier, Stephen F; Diduch, David R

    2017-12-01

    The National Athletic Trainers' Association (NATA) advocates for cervical spine immobilization on a rigid board or vacuum splint and for removal of athletic equipment before transfer to an emergency medical facility. To (1) compare triplanar cervical spine motion using motion capture between a traditional rigid spine board and a full-body vacuum splint in equipped and unequipped athletes, (2) assess cervical spine motion during the removal of a football helmet and shoulder pads, and (3) evaluate the effect of body mass on cervical spine motion. Controlled laboratory study. Twenty healthy male participants volunteered for this study to examine the influence of immobilization type and presence of equipment on triplanar angular cervical spine motion. Three-dimensional cervical spine kinematics was measured using an electromagnetic motion analysis system. Independent variables included testing condition (static lift and hold, 30° tilt, transfer, equipment removal), immobilization type (rigid, vacuum-mattress), and equipment (on, off). Peak sagittal-, frontal-, and transverse-plane angular motions were the primary outcome measures of interest. Subjective ratings of comfort and security did not differ between immobilization types ( P > .05). Motion between the rigid board and vacuum splint did not differ by more than 2° under any testing condition, either with or without equipment. In removing equipment, the mean peak motion ranged from 12.5° to 14.0° for the rigid spine board and from 11.4° to 15.4° for the vacuum-mattress splint, and more transverse-plane motion occurred when using the vacuum-mattress splint compared with the rigid spine board (mean difference, 0.14 deg/s [95% CI, 0.05-0.23 deg/s]; P = .002). In patients weighing more than 250 lb, the rigid board provided less motion in the frontal plane ( P = .027) and sagittal plane ( P = .030) during the tilt condition and transfer condition, respectively. The current study confirms similar motion in the

  4. Dental Occlusion and Ophthalmology: A Literature Review

    PubMed Central

    Marchili, Nicola; Ortu, Eleonora; Pietropaoli, Davide; Cattaneo, Ruggero; Monaco, Annalisa

    2016-01-01

    Stomatognathic system is strictly correlated to other anatomical regions; many studies investigated relationship between temporomandibular joint and posture, several articles describe cranio-facial pain from dental causes, such as trigger points. Until now less interest has been given to connections between dental occlusion and ophthalmology, even if they are important and involving. Clinical experience in dental practice claims that mandibular latero-deviation is connected both to eye dominance and to defects of ocular convergence. The trigeminal nerve is the largest and most complex of the twelve cranial nerves. The trigeminal system represents the connection between somitic structures and those derived from the branchial arches, collecting the proprioception from both somitic structures and oculomotor muscles. The intermedius nucleus of the medulla is a small perihypoglossal brainstem nucleus, which acts to integrate information from the head and neck and relays it on to the nucleus of the solitary tract where autonomic responses are generated. This intriguing neurophysiological web led our research group to investigate anatomical and functional associations between dental occlusion and vision. In conclusion, nervous system and functional pathways strictly connect vision and dental occlusion, and in the future both dentists and oculists should be more and more aware of this correlation for a better diagnosis and therapy. PMID:27733873

  5. Effectiveness of functional hand splinting and the cognitive orientation to occupational performance (CO-OP) approach in children with cerebral palsy and brain injury: two randomised controlled trial protocols

    PubMed Central

    2014-01-01

    Background Cerebral palsy (CP) and brain injury (BI) are common conditions that have devastating effects on a child’s ability to use their hands. Hand splinting and task-specific training are two interventions that are often used to address deficits in upper limb skills, both in isolation or concurrently. The aim of this paper is to describe the method to be used to conduct two randomised controlled trials (RCT) investigating (a) the immediate effect of functional hand splints, and (b) the effect of functional hand splints used concurrently with task-specific training compared to functional hand splints alone, and to task-specific training alone in children with CP and BI. The Cognitive Orientation to Occupational Performance (CO-OP) approach will be the task-specific training approach used. Methods/Design Two concurrent trials; a two group, parallel design, RCT with a sample size of 30 participants (15 per group); and a three group, parallel design, assessor blinded, RCT with a sample size of 45 participants (15 per group). Inclusion criteria: age 4-15 years; diagnosis of CP or BI; Manual Abilities Classification System (MACS) level I – IV; hand function goals; impaired hand function; the cognitive, language and behavioural ability to participate in CO-OP. Participants will be randomly allocated to one of 3 groups; (1) functional hand splint only (n=15); (2) functional hand splint combined with task-specific training (n=15); (3) task-specific training only (n=15). Allocation concealment will be achieved using sequentially numbered, sealed opaque envelopes opened by an off-site officer after baseline measures. Treatment will be provided for a period of 2 weeks, with outcome measures taken at baseline, 1 hour after randomisation, 2 weeks and 10 weeks. The functional hand splint will be a wrist cock-up splint (+/- thumb support or supination strap). Task-specific training will involve 10 sessions of CO-OP provided in a group of 2-4 children. Primary outcome

  6. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms.

    PubMed

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-12-01

    The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as "decreased," "slightly decreased," and "preserved". Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P<0.001) between the two groups. HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group (33.8 ± 8.2 HU vs. 11.9 ± 6.1 HU, P<0.001). There was no significant difference in HUs for the entire lesion between the non-occlusive (33.8 ± 8.2 HU) and corresponding normal group (34.5 ± 6.8 HU; P=0.294). Iodine perfusion tended to be visually and quantitatively preserved in lungs with

  7. Occlusal changes secondary to temporomandibular joint conditions: a critical review and implications for clinical practice

    PubMed Central

    CALDAS, Waleska; CONTI, Ana Cláudia de Castro Ferreira; JANSON, Guilherme; Paulo César Rodrigues, CONTI

    2016-01-01

    ABSTRACT The relationship between Temporomandibular Disorders (TMD) and malocclusion is an extremely critical issue in dentistry. Contrary to the old concept that malocclusion causes TMD, occlusal changes, especially those observed as sudden, may be secondary and reflect joint or muscle disorders due to the obvious connection between these structures and the dental occlusion. Objectives The aim of this article is to present the most commonly occlusal changes secondary to TMD. Methods The clinical presentation of these conditions is discussed. Details regarding diagnosis, treatment, and follow-up of patients presenting TMD prior or during treatment are also presented. Conclusions All plans for irreversible therapy should be preceded by a meticulous analysis of TMD signs and symptoms in such a way that patients are not submitted to irreversible treatment, based on an untrue occlusal relationship, secondary to articular and/or muscular disorders. When present, TMD symptoms must always be controlled to reestablish a “normal” occlusion and allow proper treatment strategy. PMID:27556214

  8. Overuse injuries of the lower extremity: shin splints, iliotibial band friction syndrome, and exertional compartment syndromes.

    PubMed

    Jones, D C; James, S L

    1987-04-01

    The authors' discussion of overuse injuries of the lower extremity encompasses shin splints, iliotibial band friction syndrome, and exertional compartment syndromes. Etiology, diagnosis, and treatment are considered for each disorder.

  9. Light transmission and preference of eye patches for occlusion treatment.

    PubMed

    Heo, Hwan; Park, Jung Won; Park, Sang Woo

    2013-01-01

    To investigate light transmission and preference for six eye patches for occlusion therapy. Six patches were examined, including; Ortopad Fun Pack, Ortopad Flesh, Kawamoto A-1, Kawamoto A-2, 3M Opticlude, and Everade Eye Guard. The size and the presence of a light blocking pad of patches were investigated. The amount of light transmitted through the patches was evaluated, using a digital light meter and a model eye, in three different environments; indoors with fluorescent light, outdoors on a sunny day, and strong light from illuminator. After patching the normal eye, the flash visual evoked potential (VEP) was measured. Thirty patients with amblyopia or horizontal strabismus, who received occlusion therapy as initial treatment, were included. After using all six patches, patients completed a 7-item questionnaire regarding the patch preference for size, color and shape, adhesive power, pain with removal, skin irritation after removing patch, parent's preference and overall opinion. All patches had a light-blocking pad, except the 3M Nexcare. Ortopad had the strongest light blocking power in the three environments, and the 3M Nexcare had the weakest power. In flash VEP, Ortopad and Kawamoto patches showed flat, but 3M Nexcare and Everade Eye Guard showed normal response. There were significant preferential differences among the patches in all the items of the questionnaire (P<0.05). In comparison between the patches respectively, 3M Nexcare received the lowest satisfaction in pain when removing a patch and skin irritation after removing a patch. Kawamoto A-2 received the lowest score in the overall satisfaction. We found differences in the light-blocking power and in the preference of the various patches for the occlusion treatment. This is a pilot study regarding only characteristics and preferences of patches. Further clinical studies regarding the relationship between characteristics or preferences of patches and outcomes of occlusion treatment are needed.

  10. Manifestations and management of veno-occlusive disease/sinusoidal obstruction syndrome in the era of contemporary therapies.

    PubMed

    Tewari, Priti; Wallis, Whitney; Kebriaei, Partow

    2017-02-01

    The concept of veno-occlusive disease (VOD), along with our understanding of it, has historically been and remains an evolving phenomenon. This review presents a broad view of VOD, also known as sinusoidal obstruction syndrome (SOS), including (1) traditional hematopoietic stem cell transplant-associated VOD/SOS, (2) late-onset VOD/SOS, (3) pulmonary VOD, and (4) VOD/SOS associated with chemotherapy only. Several VOD/SOS management modalities exist that include modes for both prophylaxis and treatment. An extensive review of the literature on monoclonal antibodies, both approved and pending approval by the US Food and Drug Administration, reveals that only a few have been associated with an increased risk for VOD/SOS. In fact, bevacizumab appears to have a protective effect against the development of VOD/SOS. As the landscape of cancer treatment changes, careful attention needs to be focused on how new therapies affect the incidence of VOD/SOS.

  11. [Clinical randomized controlled trial on ultrashort wave and magnetic therapy for the treatment of early stage distal radius fractures].

    PubMed

    Wang, Guan-Jie; Liu, Jia

    2012-07-01

    To explore the effect of application of ultrashort wave and magnetic therapy instrument on the swelling regression in distal radius fractures treated by splint external fixation in initial stage. From March 2007 to May 2010,90 patients with distal radial fracture were treated by manual reduction and splint external fixation. After manual reduction and small splints external fixation, these patients were randomly divided into electrical physical therapy group, western medicine group and the control group by the order of calling number, with 30 cases each group. In control group, there were 9 males and 21 females with an average age of (61.29 +/- 1.97) years, the patients raised and exercise the limb and fingers only. The other two groups also carried out this treatment. In electrical physical therapy group, there were 9 males and 21 females with an average age of (62.37 +/- 2.48) years, the patients were treated with ultrashort wave and magnetic therapy instrument for early intervention, once a day, 5 days for a course of treatment and three cycle were operated. In western medicine group,there were 8 males and 22 females with an average age of (60.12 +/- 2.87) years, the patients were injected with beta-aescin (20 mg, intravenous injection,once a day) for 5 days, followed by Danshen injection (20 ml, intravenous injection, once a day) for 10 days. The limb swelling of patients were assessed every day for 20 days after manual reduction and small splints external fixation. The time of swelling regression in electrical physical therapy group, western medicine group and the control group were respectively (9.62 +/- 3.32), (10.05 +/- 3.05) and (14.57 +/- 2.93) days. Both of that in electrical physical therapy group and western medicine group were shorter than that in the control group (P<0.05), then there were not statistical difference between electrical physical therapy group and western medicine group (P>0.05). The effective rate of swelling regression in electrical

  12. Laser targeted photo-occlusion of rat choroidal neovascularization without collateral damage.

    PubMed

    Nishiwaki, Hirokazu; Zeimer, Ran; Goldberg, Morton F; D'Anna, Salvatore A; Vinores, Stanley A; Grebe, Rhonda

    2002-02-01

    Laser targeted photo-occlusion (LTO) is a novel method being developed to treat choroidal neovascular membranes (CNV) in age-related and other macular degenerations. A photosensitive agent, encapsulated in heat-sensitive liposomes, is administered intravenously. A low power laser warms the targeted tissue and releases a bolus of photosensitizer. The photosensitizer is activated after it clears from the normal choriocapillaris but not from the CNV. Forty-five experimental CNV were induced in seven rats. Five weeks after LTO, complete occlusion was observed by laser targeted angiography (LTA) in 76% of treated CNV, and partial occlusion was found in the remaining 24%. The tissues outside the CNV but within the area treated by LTO showed no flow alteration and no dye leakage. All untreated CNV were patent on LTA at 5 weeks. Light microscopy and electron microscopy confirmed the results in treated and control lesions. Moreover, treated areas next to lesions showed normal photoreceptors, retinal pigment epithelium (RPE), Bruch's membrane and choriocapillaris. These results indicate that LTO may improve current photodynamic therapy by alleviating the need for repeated treatments and by avoiding the long-term risks associated with damage to the RPE and occlusion of normal choriocapillaries.

  13. Reestablishment of occlusion through overlay removable partial dentures: a case report.

    PubMed

    Bataglion, César; Hotta, Takami Hirono; Matsumoto, Wilson; Ruellas, Carlos Ventura de Oliveira

    2012-01-01

    Loss of posterior teeth may cause an imbalance in the stomatognathic system. Overlay removable partial dentures (ORPD) are a reversible and relatively inexpensive treatment for patients with severely worn teeth. This paper presents a treatment with ORPD in a 55-year-old male patient who had severe attrition in the maxillary and mandibular teeth, temporomandibular joint pain and reduced vertical dimension of occlusion (VDO). The treatment consisted in the reestablishment of the VDO using Lucia's jig, fabricating removable partial denture with reconstruction of the worn teeth without preparation. This therapy can be used as an alternative treatment to provide esthetic, function and stable occlusion in patients with severely worn teeth.

  14. Lycra splinting garments for adults with intellectual disabilities who fall due to gait or balance issues: a feasibility study.

    PubMed

    Finlayson, J; Crockett, J; Shanmugam, S; Stansfield, B

    2018-05-01

    Adults with intellectual disabilities (IDs) experience high rates of falls and have high rates of gait or balance issues which contribute to falls. Lycra splinting garments (LSGs) have potential to improve gait or balance, but they have never before been tested with adults with IDs who fall due to gait or balance issues. The aim of this study was to test in adults with IDs, the feasibility of using LSGs to improve movement and function and reduce falls, whilst also exploring usability and likely compliance. A convenience sample of nine adults with IDs wore tailored LSGs over a 6-week assessment period. Laboratory-based foot clearance, balance, and gait measures were collected pre- and post-LSG-wear. Falls charts and questionnaires on usability and likely compliance were also completed. Seven participants experienced a reduction in falls during their six weeks of LSG wear; most notably in the group of five participants who wore lycra splinting socks, compared with only two in the group of four who wore lycra splinting shorts or leggings only. Lycra splinting socks are likely to bring about positive outcomes for adults with IDs who fall due to gait/balance issues on an individual case by case basis over time, but further research is required to test this hypothesis under randomised controlled trial conditions. Potential benefits of more intrusive LSGs are outweighed by reported problems with usability and compliance. © 2018 The Authors. Journal of Intellectual Disability Research published by MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disibilities and John Wiley & Sons Ltd.

  15. Nocturnal bruxism and temporomandibular disorders.

    PubMed

    Rugh, J D; Harlan, J

    1988-01-01

    This chapter has discussed the important aspects of nocturnal bruxism and its relation to disorders of the masticatory system and headaches. Bruxism is believed to be a stress-related sleep disorder, occurring in both men and women, in children, and in adults. In most patients, bruxism results only in minor tooth wear; however, it can become extremely severe with damage occurring in essentially every part of the masticatory apparatus. Nocturnal bruxism should not be overlooked as an etiologic factor in muscular headaches. Short-term acute therapy may involve physical therapy, nocturnal electromyographic biofeedback, and medication to relieve anxiety and improve sleep. Long-term management usually includes some form of stress reduction, change in lifestyle, and an occlusal splint or nightguard to protect the teeth and masticatory system.

  16. Numeric simulation of occlusal interferences in molars restored with ultrathin occlusal veneers.

    PubMed

    Magne, Pascal; Cheung, Raymond

    2017-01-01

    Selecting material for a minimally invasive occlusal veneer reconstruction concept requires an understanding of how stresses are distributed during functional and parafunctional forces. The purpose of this in vitro study was to investigate stress distribution in a maxillary molar restored with ultrathin occlusal veneers and subjected by an antagonistic mandibular molar to clenching and working and nonworking movements. A maxillary first molar was modeled from microcomputed tomography (micro-CT) data, using medical image processing software, stereolithography editing/optimizing software, and finite element software. Simulated ultrathin occlusal veneer materials were used. The mandibular molar antagonist was a solid nondeformable geometric entity. Loads simulated clenching, working, and nonworking movements with loading of 500 N. The values of the maximum principal stress were recorded. In the clenching load situation, maximum tensile stresses were located at the occlusal veneer (52 MPa for composite resin versus 47 MPa for ceramic). In the working movement, significant additional tensile stresses were found on the palatal root (87 MPa for composite resin and 85 MPa for ceramic). In the nonworking movement, tensile stress on the ultrathin occlusal veneer increased to 118 MPa for composite resin and 143 MPa for ceramic veneers. Tensile stress peaks shifted to the mesiobuccal root (75 MPa for composite resin and 74 MPa for ceramic). The topography of stresses generated by the various occlusal interferences were clearly identified. Significant tensile stress concentrations were found within the restoration's occlusal topography and root, with the nonworking interference being the most harmful and also the most revealing of the difference between the composite resin and ceramic ultrathin occlusal veneers. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Superselective Urokinase Infusion Therapy for Dorsalis Pedis Artery Occlusion in Buerger's Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kubota, Yasushi; Kichikawa, Kimihiko; Uchida, Hideo

    1997-09-15

    Occlusion of the proximal left dorsalis pedis artery (DPA) in a patient with Buerger's disease was treated by continuous urokinase intraarterial infusion using a microcatheter. Recanalization of the DPA and healing of a toe ulcer were achieved. The patient remains asymptomatic during a 4-year follow-up.

  18. Changes in Retinal Microvasculature and Visual Acuity After Antivascular Endothelial Growth Factor Therapy in Retinal Vein Occlusion.

    PubMed

    Winegarner, Andrew; Wakabayashi, Taku; Fukushima, Yoko; Sato, Tatsuhiko; Hara-Ueno, Chikako; Busch, Caleb; Nishiyama, Issei; Shiraki, Nobuhiko; Sayanagi, Kaori; Nishida, Kentaro; Sakaguchi, Hirokazu; Nishida, Kohji

    2018-06-01

    To investigate the changes in the retinal microvasculature during the course of anti-VEGF therapy in eyes with macular edema due to retinal vein occlusion (RVO) and their association with visual outcomes. The vessel density (VD) and foveal avascular zone (FAZ) area in the superficial capillary plexus (SCP) and deep capillary plexus (DCP) were quantitatively measured by optical coherence tomography angiography (OCTA) in 48 consecutive eyes with RVO before and 1, 3, 6, 9, and 12 months after anti-VEGF therapy. Anti-VEGF therapy was performed either with ranibizumab or aflibercept following a pro re nata (PRN) regimen. The correlation between post-treatment best-corrected visual acuity (BCVA) and changes in the retinal microvasculature evaluated by OCTA were assessed. The BCVA improved significantly at 12 months (P < 0.001). Better BCVA at 12 months was significantly associated with a better VD in the SCP and DCP both at baseline (R2 = 0.524, P < 0.001 and R2 = 0.457, P < 0.001, respectively) and at 12 months (R2 = 0.521, P < 0.001 and R2 = 0.662, P < 0.001, respectively). Overall, both VD and FAZ did not change significantly during the 12 months. However, the progression of nonperfusion was observed in the SCP in 6 (13%) eyes and in the DCP in 10 (21%) eyes. The number of macular edema recurrence was significantly associated with a decrease in the VD (P = 0.006 [SCP] and P < 0.001 [DCP]) and less visual gain (P = 0.02) after treatment. Anti-VEGF therapy maintains retinal perfusion in most patients with RVO. Preserving retinal perfusion is crucial for better visual outcomes.

  19. Impact of injection therapy on retinal patients with diabetic macular edema or retinal vein occlusion.

    PubMed

    Sivaprasad, Sobha; Oyetunde, Sesan

    2016-01-01

    An important factor in the choice of therapy is the impact it has on the patient's quality of life. This survey aimed to understand treatment burden, treatment-related anxiety and worry, and practical issues such as appointment attendance and work absence in patients receiving injection therapy for diabetic macular edema (DME) or retinal vein occlusion (RVO). A European sample of 131 retinal patients completed a detailed questionnaire to elucidate the impact of injection therapy on individuals with DME or RVO. RVO and DME greatly impact a patient's quality of life. An intensive injection regimen and the requirements for multiple hospital visits place a large practical burden on the patient. Each intravitreal injection appointment (including travel time) was reported to take an average of 4.5 hours, with a total appointment burden over 6 months of 13.5 hours and 20 hours for RVO and DME patients, respectively. This creates a significant burden on patient time and may make appointment attendance difficult. Indeed, 53% of working patients needed to take at least 1 day off work per appointment and 71% of patients required a carer's assistance at the time of the injection appointment, ~6.3 hours per injection. In addition to practical issues, three-quarters of patients reported experiencing anxiety about their most recent injection treatment, with 54% of patients reporting that they were anxious for at least 2 days prior to the injection. Patients' most desired improvement to their treatment regimen was to have fewer injections and to require fewer appointments, to achieve the same visual results. Patients' quality of life is clearly very affected by having to manage an intensive intravitreal injection regimen, with a considerable treatment burden having a large negative effect. Reducing the appointment burden to achieve the same visual outcomes and the provision of additional support for patients to attend appointments would greatly benefit those receiving intravitreal

  20. Evidence of an application of a variable MEMS capacitive sensor for detecting shunt occlusions

    NASA Astrophysics Data System (ADS)

    Apigo, David J.; Bartholomew, Philip L.; Russell, Thomas; Kanwal, Alokik; Farrow, Reginald C.; Thomas, Gordon A.

    2017-04-01

    A sensor was tested subdural and in vitro, simulating a supine infant with a ventricular-peritoneal shunt and controlled occlusions. The variable MEMS capacitive device is able to detect and forecast blockages, similar to early detection procedures in cancer patients. For example, with gradual occlusion development over a year, the method forecasts a danger over one month ahead of blockage. The method also distinguishes between ventricular and peritoneal occlusions. Because the sensor provides quantitative data on the dynamics of the cerebrospinal fluid, it can help test new therapies and work toward understanding hydrocephalus as well as idiopathic normal pressure hydrocephalus. The sensor appears to be a substantial advance in treating brain injuries treated with shunts and has the potential to bring significant impact in a clinical setting.

  1. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference.

    PubMed

    Ono, Yumie; Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-11-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near-infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task-related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task-related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD.

  2. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference

    PubMed Central

    Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-01-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near‐infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task‐related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task‐related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD. PMID:29744159

  3. SPLINTS: small-molecule protein ligand interface stabilizers.

    PubMed

    Fischer, Eric S; Park, Eunyoung; Eck, Michael J; Thomä, Nicolas H

    2016-04-01

    Regulatory protein-protein interactions are ubiquitous in biology, and small molecule protein-protein interaction inhibitors are an important focus in drug discovery. Remarkably little attention has been given to the opposite strategy-stabilization of protein-protein interactions, despite the fact that several well-known therapeutics act through this mechanism. From a structural perspective, we consider representative examples of small molecules that induce or stabilize the association of protein domains to inhibit, or alter, signaling for nuclear hormone, GTPase, kinase, phosphatase, and ubiquitin ligase pathways. These SPLINTS (small-molecule protein ligand interface stabilizers) drive interactions that are in some cases physiologically relevant, and in others entirely adventitious. The diverse structural mechanisms employed suggest approaches for a broader and systematic search for such compounds in drug discovery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Continuous passive motion and physical therapy (CPM) versus physical therapy (PT) versus delayed physical therapy (DPT) after surgical release for elbow contractures; a study protocol for a prospective randomized controlled trial.

    PubMed

    Viveen, Jetske; Doornberg, Job N; Kodde, Izaak F; Goossens, Pjotr; Koenraadt, Koen L M; The, Bertram; Eygendaal, Denise

    2017-11-22

    The elbow is prone to stiffness after trauma. To regain functional elbow motion several conservative- and surgical treatment options are available. Conservative treatment includes physical therapy, intra-articular injections with corticosteroids and a static progressive or dynamic splinting program. If conservative treatment fails, an operative release of the posttraumatic stiff elbow is often performed. The best Evidence-Based rehabilitation protocol for patients after an operative release is unknown to date and differs per surgeon, hospital and country. Options include early- or delayed motion supervised by a physical therapist, immediate continuous passive motion (CPM), (night) splinting and a static progressive or dynamic splinting program. The SET-Study (Stiff Elbow Trial) is a single-centre, prospective, randomized controlled trial. The primary objective of this study is to compare the active Range of Motion (ROM) (flexion arc and rotational arc) twelve months after surgery between three groups. The first group will receive in-hospital CPM in combination with early motion Physical Therapy (PT) supervised by a physical therapist, the second group will receive only in-hospital early motion PT supervised by a physical therapist and the third group will receive outpatient supervised PT from postoperative day seven till ten. Secondary outcome measures will be Patient Reported Outcome Measures (PROMs) including the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), the quick Disabilities of Arm, Shoulder and Hand (qDASH) score, Visual Analogue pain Scale in rest and activity (VAS), Pain Catastrophizing Scale (PCS), the Short Form (SF)-36, the Centre for Epidemiological Studies Depression Scale Revised (CESD-R) and the Work Rehabilitation Questionnaire (WORQ) for the upper limb. A successful completion of this trial will provide evidence on the best rehabilitation protocol in order to (re)gain optimal motion after surgical release of the stiff elbow

  5. [Long-Term Multidisciplinary Therapy for Multiple Liver Metastases from Colorectal Cancer with Biliary Drainage for Occlusive Jaundice--A Case Report].

    PubMed

    Okamura, Shu; Mikami, Koji; Murata, Kohei; Nushijima, Yoichirou; Okada, Kazuyuki; Yanagisawa, Tetsu; Fukuchi, Nariaki; Ebisui, Chikara; Yokouchi, Hideoki; Kinuta, Masakatsu

    2015-11-01

    Here, we report the case of a 43-year-old man who was diagnosed with sigmoid colon cancer with synchronous multiple liver metastases following resection of a primary lesion. Subsequent mFOLFOX+BV therapy elicited a marked response in the liver metastases, which led to the patient undergoing hepatic (S7) radiofrequency ablation (RFA), hepatic resection (lateral segmentectomy and partial [S5] resection), and cholecystectomy. Six months later, transluminal RFA was repeated because liver (S7) metastasis recurred, and 8 courses of XELOX plus BV therapy were administered. As obstructive jaundice due to recurrence of the liver metastases developed after a 6 months hiatus in chemotherapy, we endoscopically inserted a biliary stent. Despite reducing IRIS plus BV therapy, obstructive jaundice developed again, and 3 intrahepatic biliary stents were inserted with percutaneous transhepatic biliary drainage. To date, the patient has been alive for 4 years since the initial resection of the primary lesion after undergoing consecutive systemic chemotherapy with different regimens. Some studies have shown that in cases of obstructive jaundice caused by advanced gastrointestinal cancer, longer survival could be expected by reducing the severity of jaundice, suggesting that resuming chemotherapy as well as improving the severity of jaundice could contribute to better outcomes. The patient in the present case was successfully treated twice with biliary drainage for occlusive jaundice and chemotherapy, suggesting that a combination of multidisciplinary therapy and adequate local therapy such as biliary drainage could be important for the treatment of metastatic liver cancer.

  6. Occlusion therapy improves phase-alignment of the cortical response in amblyopia.

    PubMed

    Kelly, John P; Tarczy-Hornoch, Kristina; Herlihy, Erin; Weiss, Avery H

    2015-09-01

    The visual evoked potential (VEP) generated by the amblyopic visual system demonstrates reduced amplitude, prolonged latency, and increased variation in response timing (phase-misalignment). This study examined VEPs before and after occlusion therapy (OT) and whether phase-misalignment can account for the amblyopic VEP deficits. VEPs were recorded to 0.5-4cycles/degree gratings in 10 amblyopic children (2-6years age) before and after OT. Phase-misalignment was measured by Fourier analysis across a limited bandwidth. Signal-to-noise ratios (SNRs) were estimated from amplitude and phase synchrony in the Fourier domain. Responses were compared to VEPs corrected for phase-misalignment (individual epochs shifted in time to correct for the misalignment). Before OT, amblyopic eyes (AE) had significantly more phase-misalignment, latency prolongation, and lower SNR relative to the fellow eye. Phase-misalignment contributed significantly to low SNR but less so to latency delay in the AE. After OT, phase-alignment improved, SNR improved and latency shortened in the AE. Raw averaged waveforms from the AE improved after OT, primarily at higher spatial frequencies. Correcting for phase-misalignment in the AE sharpened VEP peak responses primarily at low spatial frequencies, but could not account for VEP waveform improvements in the AE after OT at higher spatial frequencies. In summary, VEP abnormalities from the AE are associated with phase-misalignment and reduced SNR possibly related to desynchronization of neuronal activity. The effect of OT on VEP responses is greater than that accounted for by phase-misalignment and SNR alone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Reconstruction of attached soft tissue around dental implants by acelluar dermal matrix grafts and resin splint

    PubMed Central

    Liu, Changying; Su, Yucheng; Tan, Baosheng; Ma, Pan; Wu, Gaoyi; Li, Jun; Geng, Wei

    2014-01-01

    Objectives: The purpose of this study was to recommend a new method using acellular dermal matrix graft and resin splint to reconstruct the attached soft tissue around dental implants in patients with maxillofacial defects. Materials and methods: Total 8 patients (3 male and 5 female patients) diagnosed with maxillofacial defects and dentition defects caused by tumors, fractures or edentulous jaw, were selected for this study. Dental implants were routinely implanted at the edentulous area. Acellular dermal matrix heterografts and resin splint were used to increase the attached soft tissue. The width of attached gingiva in the labial or buccal surface at edentulous area was measured before surgical procedures and after the completion of superstructures. Paired t-test was applied to assess the change of quantitative variables. All tests were 2-tailed, and P < 0.05 was considered statistically significant. Results: The dense connective tissue around implants could be reconstructed one month after the completion of surgical procedures, and the epithelial cuff around the implant neck established very well. The width of attached gingival tissue in the patients increased significantly from a mean of 0.61 ± 0.75 mm to 6.25 ± 1.04 mm. The patients were fully satisfied with the esthetic and functional results achieved. Conclusions: The acellular dermal matrix graft could be used to increase the attached gingiva around dental implants in these patients with maxillofacial defects. The resin splint could facilitate the healing of graft. PMID:25663964

  8. Evaluation of Occlusion Treatment Outcomes for Unilateral Amblyopia Using Different Definitions of Outcome.

    PubMed

    Su, Liping; Yan, Hong; Xing, Yongxin; Zhang, Yuhai; Zhu, Baoyi

    2016-01-01

    We studied 87 cases of children aged 3 to 10 with unilateral amblyopia (with types of anisometropia, strabismus, or both) who received good recovery after occlusion therapy. The proportional improvement had moderate positive correlation with amblyopic eye improvement (p < 0.05) and negative correlation with residual amblyopia (p < 0.05); the amblyopia residual had no correlation with amblyopic eye improvement (p < 0.05). In multivariate analysis, the proportion of the deficit-corrected of the <5 years group with 2 h/d occlusion therapy group displayed the best outcome (p < 0.05). The BCVA of amblyopia eye and residual amblyopia are simple and direct indicators for clinical application. The proportion of the deficit-corrected method should be graded as the proportion of change in visual acuity with respect to the absolute potential for improvement, and these optimum outcomes can provide powerful evidence for good therapeutic effect.

  9. Outcomes of 6 hour part-time occlusion treatment combined with near activities for unilateral amblyopia.

    PubMed

    Park, Kyoung Soo; Chang, Yoon Hee; Na, Kyung Doo; Hong, Samin; Han, Sueng Han

    2008-03-01

    To evaluate the outcome of the part-time occlusion therapy with near activities in monocular amblyopic patients according to gender, age, severity of amblyopia, and the cause of amblyopia. Fifty eight patients who were prescribed part-time occlusion therapy with near activity from July 1998 to October 2004, were included in this retrospective study. All patients were divided into groups by gender, age, severity of amblyopia, and the cause of amblyopia. Main outcome measures were best corrected visual acuity, line improvement, and success rate. At the end of patch therapy, visual acuity improved from baseline by an average of 3.2+/-2.5 lines (0.33+/-0.26 log MAR), and follow-up period was 19.71+/-14.61 months (1.62+/-1.20 years). At the last follow-up, visual acuity improved from baseline by an average of 3.7+/-2.4 lines (0.38+/-0.26 log MAR), and follow-up period was 37.41+/-25.83 months (3.08+/-2.12 years). The success rate was 86% (50 patients) at the end of patch therapy. In 44 patients out of 50 patients (88%), the visual acuity was maintained. While 43 patients out of 47 patients who were less than 7 years old (91%) achieved success, 7 patients out of 11 patients 7 years or older (64%) achieved success (p=0.035). Six-hour part-time occlusion treatment combined with near activities appears to be favorable in treating 58 children during follow-up of mean 3.08 years. The significant factor was the age at initial treatment.

  10. Association of Far-Infrared Radiation Therapy and Ankle-Brachial Index of Patients on Hemodialysis with Peripheral Artery Occlusive Disease

    PubMed Central

    Chen, Szu-Chia; Lee, Mei-Yueh; Huang, Jiun-Chi; Kuo, I-Ching; Mai, Hsiu-Chin; Kuo, Po-Lin; Chang, Jer-Ming; Hwang, Shang-Jyh; Chen, Hung-Chun

    2016-01-01

    Background and Aim: The ankle-brachial index (ABI) is recognized to be a good marker for atherosclerosis, and is useful in the diagnosis of peripheral artery occlusive disease (PAOD) which is prevalent among patients on hemodialysis (HD). Methods: This randomized trial aimed to evaluate the effect of far-infrared radiation (FIR) therapy on ABI in HD patients with PAOD. PAOD was defined as patients with ABI < 0.95. One hundred and eight HD patients were enrolled, including 50 in the control group and 58 in the FIR group. A WS TY101 FIR emitter was applied for 40 minutes during each HD session, three times per week for six months. The ABI was measured before and after the FIR therapy. Results: Regardless of FIR therapy, the bilateral ABI decreased (in the FIR group, left: 0.88±0.22 to 0.85±0.24, p = 0.188; right: 0.92±0.20 to 0.90±0.23, p = 0.372; in control group, left: 0.91±0.23 to 0.88±0.21, p = 0144; right: 0.93±0.17 to 0.89±0.21, p = 0.082). Multivariate logistic analysis of the FIR group revealed that high uric acid (odds ratio [OR]: 2.335; 95% confidence interval [CI]: 1.117-4.882; p=0.024) and aspirin use (OR: 16.463; 95% CI: 1.787-151.638; p=0.013) were independently associated with increased bilateral ABI after FIR therapy. Conclusions: This study demonstrates that ABI is not increased after FIR therapy in HD patients with PAOD. However, in the FIR group, patients with higher uric acid level or those who used aspirin have increased bilateral ABI after FIR therapy. PMID:27994503

  11. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raupach, J., E-mail: janraupach@seznam.cz; Lojik, M., E-mail: miroslav.lojik@fnhk.cz; Chovanec, V., E-mail: chovanec.v@seznam.cz

    2016-02-15

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due tomore » a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %.« less

  12. Contralateral Occlusion Test: The effect of external ear canal occlusion on hearing thresholds.

    PubMed

    Reis, Luis Roque; Fernandes, Paulo; Escada, Pedro

    Bedside testing with tuning forks may decrease turnaround time and improve decision making for a quick qualitative assessment of hearing loss. The purpose of this study was to quantify the effects of ear canal occlusion on hearing, in order to decide which tuning fork frequency is more appropriate to use for quantifying hearing loss with the Contralateral Occlusion Test. Twenty normal-hearing adults (forty ears) underwent sound field pure tone audiometry with and without ear canal occlusion. Each ear was tested with the standard frequencies. The contralateral ear was suppressed with by masking. Ear occlusion was performed by two examiners. Participants aged between 21 and 30 years (25.6±3.03 years) showed an increase in hearing thresholds with increasing frequencies from 19.94dB (250Hz) to 39.25dB (2000Hz). The threshold difference between occluded and unoccluded conditions was statistically significant and increased from 10.69dB (250Hz) to 32.12dB (2000Hz). There were no statistically significant differences according to gender or between the examiners. The occlusion effect increased the hearing thresholds and became more evident with higher frequencies. The occlusion method as performed demonstrated reproducibility. In the Contralateral Occlusion Test, 256Hz or 512Hz tuning forks should be used for diagnosis of mild hearing loss, and a 2048Hz tuning fork should be used for moderate hearing loss. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  13. Enlargement of basilar artery aneurysms following balloon occlusion--"water-hammer effect". Report of two cases.

    PubMed

    Kwan, E S; Heilman, C B; Shucart, W A; Klucznik, R P

    1991-12-01

    Two patients with distal basilar aneurysms were treated with intra-aneurysmal balloon occlusion. After apparently successful therapy, follow-up angiograms demonstrated aneurysm enlargement with balloon migration distally in the sac. Geometric mismatch between the base of the balloons and the aneurysm neck together with transmitted pulsation through the 2-hydroxyl-ethylmethacrylate (HEMA)-filled balloon directly contributed to aneurysm enlargement. In this report, the authors discuss the problems of progressive aneurysm enlargement due to a "water-hammer effect" and the possibility of hemorrhage following subtotal occlusion.

  14. Microfluidic Thrombosis under Multiple Shear Rates and Antiplatelet Therapy Doses

    PubMed Central

    Ku, David N.; Forest, Craig R.

    2014-01-01

    The mainstay of treatment for thrombosis, the formation of occlusive platelet aggregates that often lead to heart attack and stroke, is antiplatelet therapy. Antiplatelet therapy dosing and resistance are poorly understood, leading to potential incorrect and ineffective dosing. Shear rate is also suspected to play a major role in thrombosis, but instrumentation to measure its influence has been limited by flow conditions, agonist use, and non-systematic and/or non-quantitative studies. In this work we measured occlusion times and thrombus detachment for a range of initial shear rates (500, 1500, 4000, and 10000 s−1) and therapy concentrations (0–2.4 µM for eptifibatide, 0–2 mM for acetyl-salicylic acid (ASA), 3.5–40 Units/L for heparin) using a microfluidic device. We also measured complete blood counts (CBC) and platelet activity using whole blood impedance aggregometry. Effects of shear rate and dose were analyzed using general linear models, logistic regressions, and Cox proportional hazards models. Shear rates have significant effects on thrombosis/dose-response curves for all tested therapies. ASA has little effect on high shear occlusion times, even at very high doses (up to 20 times the recommended dose). Under ASA therapy, thrombi formed at high shear rates were 4 times more prone to detachment compared to those formed under control conditions. Eptifibatide reduced occlusion when controlling for shear rate and its efficacy increased with dose concentration. In contrast, the hazard of occlusion from ASA was several orders of magnitude higher than that of eptifibatide. Our results show similar dose efficacy to our low shear measurements using whole blood aggregometry. This quantitative and statistically validated study of the effects of a wide range of shear rate and antiplatelet therapy doses on occlusive thrombosis contributes to more accurate understanding of thrombosis and to models for optimizing patient treatment. PMID:24404131

  15. Branch retinal vein occlusion followed by central retinal artery occlusion in Churg-Strauss syndrome: unusual ocular manifestations in allergic granulomatous angiitis.

    PubMed

    De Salvo, Gabriella; Li Calzi, Concetta; Anastasi, Mario; Lodato, Gaetano

    2009-01-01

    To describe a rare branch retinal vein occlusion (BRVO) followed by central retinal artery occlusion (CRAO) in a patient with Churg-Strauss syndrome (CSS). A 55-year-old man with a not yet diagnosed CSS developed a BRVO in the left eye and 1 year later a CRAO with painless and acute vision loss in the same eye. Medical history included bronchial asthma, history of allergy, eosinophilic pneumonia, bilateral pleuric and pericardial effusion, hypereosinophilia, and purpuric vasculitis. CRAO in the left eye was diagnosed by retinal whitening and a cherry red spot with coexisting old BRVO evidenced by previous laser photocoagulation. Corticosteroids and cyclophosphamide therapy improved his general condition but no visual recovery occurred. BRVO and CRAO can occur in the same eye in CSS. In the presence of systemic signs or symptoms, it is important to rule out systemic vasculitis in order to start appropriate immune-modulatory treatment thereby avoiding unnecessary mortality.

  16. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    PubMed

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  17. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki

    2001-07-15

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source.

  18. Acute stroke with major intracranial vessel occlusion: Characteristics of cardioembolism and atherosclerosis-related in situ stenosis/occlusion.

    PubMed

    Horie, Nobutaka; Tateishi, Yohei; Morikawa, Minoru; Morofuji, Yoichi; Hayashi, Kentaro; Izumo, Tsuyoshi; Tsujino, Akira; Nagata, Izumi; Matsuo, Takayuki

    2016-10-01

    Acute ischemic stroke with major intracranial vessel occlusion is commonly due to cardioembolic or atherosclerosis-related in situ stenosis/occlusion, and immediate identification of these subtypes is important to establish the optimal treatment strategy. The aim of this study was to clarify the differences in clinical presentation, radiological findings, neurological temporal courses, and outcomes between these etiologies, which have not been fully evaluated. Consecutive emergency patients with acute ischemic stroke were retrospectively reviewed. Among them, patients with stroke with major intracranial vessel occlusion were analyzed with a focus on clinical and radiological findings, and a comparison was performed for those with cardioembolic or atherosclerosis-related in situ stenosis/occlusion. Of 1053 patients, 80 had stroke with acute major intracranial vessel occlusion (45 with cardioembolic and 35 with atherosclerosis-related in situ stenosis/occlusion). Interestingly, the susceptibility vessel sign (SVS) on T2-weighted MR angiography was more frequently detected in cardioembolic stroke (80.0%) than in atherosclerosis (in situ stenosis: 5.9%, chronic occlusion: 14.3%). Moreover, the proximal intra-arterial signal (IAS) on arterial spin labeling MRI and the distal IAS on fluid attenuated inversion recovery MRI was less frequently detected in chronic occlusion (27.3% and 50.0%, respectively) than in acute occlusion due to cardioembolic or in situ stenosis. Multivariate regression analysis showed that the SVS was significantly related to cardioembolism (adjusted odds ratio (OR): 21.68, P=0.004). Clinical characteristics of acute stroke with major intracranial vessel occlusion differ depending on the etiology. The SVS and proximal/distal IAS on MRI are useful to distinguish between cardioembolic and atherosclerotic-related in situ stenosis/occlusion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Resolution in partially accomodative esotropia during occlusion treatment for amblyopia.

    PubMed

    Koc, F; Ozal, H; Yasar, H; Firat, E

    2006-03-01

    To evaluate alignment changes in partially accommodative esotropia during occlusion treatment for amblyopia. Changes at the deviation angles of 63 partially accommodative esotropia patients, who had occlusion treatment for amblyopia, were evaluated retrospectively. Mean deviation angle at the start of therapy without glasses was 45 PD (10-90 PD) and became 27 PD (5-70 PD) after at least 2 months with glasses. During 12 (2-36) months of occlusion period, mean manifest deviation angle with glasses decreased to 11 PD (0-50) (P < 0.001) and amblyopia resolved in 71.5% of the cases. After termination of amblyopia treatment 24 (38%) cases had surgery for the residual deviation but if we had planned surgery before amblyopia treatment, 81% of the patients would have had surgery. Should amblyopia be treated initially or should we operate first in patients with strabismus and amblyopia together? Our research suggests that we should not hurry to operate in high hypermetropic partially accommodative cases, which have amblyopia and a long-term history of strabismus. Initial amblyopia treatment in these cases allows time for resolution of the nonaccomodative component in strabismus and can significantly decrease the necessity for surgery.

  20. Efficacy of Combined Ultrasound-Guided Steroid Injection and Splinting in Patients With Carpal Tunnel Syndrome: A Randomized Controlled Trial.

    PubMed

    Wang, Jia-Chi; Liao, Kwong-Kum; Lin, Kon-Ping; Chou, Chen-Liang; Yang, Tsui-Fen; Huang, Yu-Fang; Wang, Kevin A; Chiu, Jan-Wei

    2017-05-01

    To compare the effectiveness of local steroid injection plus splinting with that of local steroid injection alone using clinical and electrophysiological parameters in patients with carpal tunnel syndrome (CTS). Randomized controlled study with 12 weeks of follow-up. Tertiary care center. Volunteer sample of patients (N=52) diagnosed with CTS. Participants were randomly assigned to the steroid injection group (n=26) or the steroid injection-plus-splinting group (n=26). Patients of both groups received ultrasound-guided steroid injection with 1mL of 10mg (10mg/mL) triamcinolone acetonide (Shincort) and 1mL of 2% lidocaine hydrochloride (Xylocaine). Participants in the second group also wore a volar splint in the neutral position while sleeping and also during daytime whenever possible for the 12-week intervention period. Participants were evaluated before the treatment and at 6 and 12 weeks after the onset of treatment. The primary outcome measure was Boston Carpal Tunnel Questionnaire scores. The secondary outcome measures were as follows: scores on the visual analog scale for pain; electrophysiological parameters, including median nerve distal motor latency, sensory nerve conduction velocity (SNCV), and compound muscle action potential and sensory nerve action potential (SNAP) amplitudes; and patient's subjective impression of improvement. At 12-week follow-up, improvements in symptom severity and functional status scores on the Boston Carpal Tunnel Questionnaire as well as SNCV and SNAP amplitudes were greater in the group that received steroid injection combined with splinting than in the group that received steroid injection alone. The between-group difference was .48 points (95% confidence interval [CI], .09-.88 points; P=.032) in the Symptom Severity Scale score, .37 points (95% CI, .06-.67 points; P=.019) in the Functional Status Scale score, 3.38m/s (95% CI, 0.54-6.22m/s; P=.015) in the SNCV amplitude, and 3.21μV (95% CI, 0.00-6.46μV; P=.025) in the SNAP

  1. ICA Occlusion by an ACTH-secreting pituitary adenoma post-TSS and irradiation

    PubMed Central

    El-Zammar, Diala; Akagami, Ryojo

    2011-01-01

    Occlusion of intracranial arteries by a pituitary adenoma with ensuing infarction is a rare occurrence. In this case study, we show the instance of a pituitary macroadenoma and apoplexy causing mechanical obstruction of the internal carotid artery with consequent infarction following transphenoidal surgery (TSS) and radiation therapy in a patient with Cushing's disease. We report a 44-year-old woman presented with amenorrhea and headaches. Necessary investigations, resection by TSS, and microscopic examination revealed an adenocorticotropin (ACTH)-secreting pituitary macroadenoma. The pituitary tumour recurred in subsequent years, resulting in the development of Cushing's disease and syndrome. Despite two more transphenoidal surgeries, radiotherapy, and medical suppressive therapy, the pituitary adenoma continued to enlarge, and the hypercortisolemia and Cushingoid symptoms persisted. A craniotomy was arranged as the next step in the treatment strategy. Only hours prior to the scheduled surgery, the patient developed left-sided hemiplegia, was diagnosed with acute occlusion of the right ICA and underwent an emergency bifrontal craniotomy with evacuation of the tumour and decompression. Pathological examination revealed evidence of apoplexy in the ACTH-secreting pituitary adenoma. This case demonstrates the vast scope of complications that can arise from pituitary adenomas despite combination therapy and forewarns clinicians to be prepared to manage these infrequent but conceivable occurrences. PMID:22399870

  2. Outcomes of 6 Hour Part-time Occlusion Treatment Combined with Near Activities for Unilateral Amblyopia

    PubMed Central

    Park, Kyoung Soo; Chang, Yoon-Hee; Na, Kyung Doo; Hong, Samin

    2008-01-01

    Purpose To evaluate the outcome of the part-time occlusion therapy with near activities in monocular amblyopic patients according to gender, age, severity of amblyopia, and the cause of amblyopia. Methods Fifty eight patients who were prescribed part-time occlusion therapy with near activity from July 1998 to October 2004, were included in this retrospective study. All patients were divided into groups by gender, age, severity of amblyopia, and the cause of amblyopia. Main outcome measures were best corrected visual acuity, line improvement, and success rate. Results At the end of patch therapy, visual acuity improved from baseline by an average of 3.2±2.5 lines (0.33±0.26 log MAR), and follow-up period was 19.71±14.61 months (1.62±1.20 years). At the last follow-up, visual acuity improved from baseline by an average of 3.7±2.4 lines (0.38±0.26 log MAR), and follow-up period was 37.41±25.83 months (3.08±2.12 years). The success rate was 86% (50 patients) at the end of patch therapy. In 44 patients out of 50 patients (88%), the visual acuity was maintained. While 43 patients out of 47 patients who were less than 7 years old (91%) achieved success, 7 patients out of 11 patients 7 years or older (64%) achieved success (p=0.035). Conclusions Six-hour part-time occlusion treatment combined with near activities appears to be favorable in treating 58 children during follow-up of mean 3.08 years. The significant factor was the age at initial treatment. PMID:18323702

  3. Amputee skin condition: occlusion, stratum corneum hydration and free amino acid levels.

    PubMed

    Visscher, Marty O; Robinson, Marisa; Fugit, Benetta; Rosenberg, Richard J; Hoath, Steven B; Randall Wickett, R

    2011-03-01

    Patients with a prosthetic limb report negative skin effects, including irritation, rash and chafing, which can lead to infection, discomfort and reduced wear time to significantly impact normal activities. The aims were to examine the epidermal integrity (transepidermal water loss, TEWL), stratum corneum (SC) hydration [moisture accumulation rate (MAT)], friction and biomechanical properties in active below the knee amputees and to determine the effects of an inert sock liner on skin condition. The liner reduced hydration, TEWL and friction and increased elasticity versus the amputee's conventional skin care methods. Residual limb TEWL was increased and MAT was reduced versus the contralateral normal skin. In a second study, we hypothesized that complete occlusion would decrease free amino acids (FAA) and quantified them by high performance liquid chromatography in an adult volar forearm model. Occlusion with a water vapor impermeable wet dressing led to increased TEWL, erythema and dryness and reduced MAT versus normal skin, comparable to the results in the amputees. The FAA levels were significantly reduced for the occluded sites. The results suggest that residual limb occlusion in amputees may block the formation of FAA in the upper SC. Therapies based on replacement of water binding FAAs, may alleviate the consequences of long-term occlusion.

  4. [Temporomandibular joint, occlusion and bruxism].

    PubMed

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Part-time vs. full-time occlusion for amblyopia: evidence for part-time patching.

    PubMed

    Matta, Noelle S; Silbert, David I

    2013-01-01

    Amblyopia is characterized by a decreased uncorrectable visual acuity in a structurally normal eye. Occlusion therapy has been used for years to improve acuity, and, traditionally, practitioners have utilized full-time patching. This article will explore more recent research looking at using part-time patching in the treatment of amblyopia.

  6. Implant rehabilitation in bruxism patient

    PubMed Central

    Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas

    2014-01-01

    A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215

  7. Surgical treatment of central retinal vein occlusion.

    PubMed

    Berker, Nilufer; Batman, Cosar

    2008-05-01

    The treatment of central retinal vein occlusion (CRVO) is still a subject of debate. Medical therapy efforts, as well as retinal laser photocoagulation, have mostly dealt with management of the sequelae of CRVO, and have shown limited success in improving visual acuity. The unsatisfactory results of such therapeutic efforts led to the development of new treatment strategies focused on the surgical treatment of the occluded retinal vein. The purpose of this review is to summarize the outcomes of commonly reported surgical treatment strategies and to review different opinions on the various surgical approaches to the treatment of CRVO.

  8. Hybrid Assistive Neuromuscular Dynamic Stimulation Therapy: A New Strategy for Improving Upper Extremity Function in Patients with Hemiparesis following Stroke.

    PubMed

    Fujiwara, Toshiyuki; Kawakami, Michiyuki; Honaga, Kaoru; Tochikura, Michi; Abe, Kaoru

    2017-01-01

    Hybrid Assistive Neuromuscular Dynamic Stimulation (HANDS) therapy is one of the neurorehabilitation therapeutic approaches that facilitates the use of the paretic upper extremity (UE) in daily life by combining closed-loop electromyography- (EMG-) controlled neuromuscular electrical stimulation (NMES) with a wrist-hand splint. This closed-loop EMG-controlled NMES can change its stimulation intensity in direct proportion to the changes in voluntary generated EMG amplitudes recorded with surface electrodes placed on the target muscle. The stimulation was applied to the paretic finger extensors. Patients wore a wrist-hand splint and carried a portable stimulator in an arm holder for 8 hours during the daytime. The system was active for 8 hours, and patients were instructed to use their paretic hand as much as possible. HANDS therapy was conducted for 3 weeks. The patients were also instructed to practice bimanual activities in their daily lives. Paretic upper extremity motor function improved after 3 weeks of HANDS therapy. Functional improvement of upper extremity motor function and spasticity with HANDS therapy is based on the disinhibition of the affected hemisphere and modulation of reciprocal inhibition. HANDS therapy may offer a promising option for the management of the paretic UE in patients with stroke.

  9. 35% Good Outcome Rate in IV-tPA treated Patients with CTA Confirmed Severe Anterior Circulation Occlusive Stroke

    PubMed Central

    González, R. Gilberto; Furie, Karen L.; Goldmacher, Gregory V.; Smith, Wade S.; Kamalian, Shervin; Payabvash, Seyedmehdi; Harris, Gordon J.; Halpern, Elkan F.; Koroshetz, Walter J.; Camargo, Erica C. S.; Dillon, William P.; Lev, Michael H.

    2015-01-01

    BACKGROUND AND PURPOSE To determine the effect of IV-tPA on outcomes in patients with severe major anterior circulation ischemic stroke. METHODS Prospectively, 649 acute stroke patients had admission NIH stroke scale scores (NIHSS), non-contrast CT, CT angiography (CTA), and 6-month outcome assessed using modified Rankin scale (mRS). IV-tPA treatment decisions were made prior to CTA, at the time of non-contrast CT scanning, as per routine clinical protocol. Severe symptoms were defined as NIHSS>10. Poor outcome was defined as mRS>2. Major occlusions were identified on CTA. Univariate and multivariate stepwise-forward logistic regression analyses of the full cohort were performed. RESULTS Of 649 patients, 188 (29%) presented with NIHSS>10, and 64/188 (34%) of these received IV-tPA. Admission NIHSS, large artery occlusion, and IV-tPA all independently predicted good outcomes, however a significant interaction existed between IV-tPA and occlusion (p<0.001). Of NIHSS>10 patients with anterior circulation occlusion, twice the percentage had good outcomes if they received IV-tPA (17/49, 35%), than if they did not (13/77, 17%; p=0.031). The “number needed to treat” was 7 (95% CI = 3–60). CONCLUSIONS IV-tPA treatment resulted in significantly more good outcomes in severely symptomatic stroke patients with major anterior circulation occlusions. The 35% good outcome rate was similar to rates found in endovascular therapy trials. Vascular imaging may help in patient selection and stratification for trials of IV-thrombolytic and endovascular therapies. PMID:24003051

  10. RETINAL VEIN OCCLUSIONS, FROM BASICS TO THE LATEST TREATMENT.

    PubMed

    Ho, Mary; Liu, David T L; Lam, Dennis S C; Jonas, Jost B

    2016-03-01

    To review the pathophysiology, diagnosis, and updated treatments of retinal vein occlusions (RVOs). A review of the literature was performed, focusing on the epidemiology, pathophysiology, diagnosis, and treatments (including both medical and surgical treatments) of RVO. Based on this review, a comprehensive overview was provided regarding the topic of RVO and focused on recent treatment updates. Retinal vein occlusions have an age- and sex-standardized prevalence of 5.20 per 1,000 for any RVO, 4.42 per 1,000 for branch RVO, 0.80 per 1,000 for central RVO. Worldwide, an estimated 16.4 million adults are affected by RVOs, with 2.5 million affected by central RVO and 13.9 million affected by branch RVO. Retinal vein occlusion is recognized as an important cause of blindness and the diagnostic approaches and treatment options for RVO are reviewed and reported. The current treatment options including medical treatments (bevacizumab, ranibizumab, aflibercept, triamcinolone, and dexamethasone implants) and surgical alternatives were reviewed and reported with summaries on the corresponding strength of evidence. Despite the understanding of this disease entity, challenges persist in the long-term treatment of RVO-related complications and visual loss. This review provided a detailed summary on the rationality and efficacy of recently developed treatment regimes and evaluated the potential benefit of combination therapy.

  11. Hepatic veno-occlusive disease in pediatric stem cell transplantation: impact of pre-emptive antithrombin III replacement and combined antithrombin III/defibrotide therapy.

    PubMed

    Haussmann, Ursula; Fischer, Joachim; Eber, Stefan; Scherer, Franziska; Seger, Reinhard; Gungor, Tayfun

    2006-06-01

    Hepatic veno-occlusive disease (VOD) remains a serious complication after hematopoietic stem cell transplantation (HSCT). Based on a protective effect of antithrombin III (ATIII) on endothelial cells, we assessed the incidence of VOD after pre-emptive ATIII replacement and the outcome of VOD after combined high dose defibrotide (DF) and ATIII therapy. This prospective case series comprised two phases. In the first phase 71 children did not receive any specific VOD prophylaxis or therapy (controls). In the second phase 91 children were given pre-emptive ATIII replacement in case of decreased ATIII activity (< or =70%). If VOD was diagnosed clinically (according to modified Seattle criteria), high dose defibrotide (60 mg/day) and ATIII replacement therapy were combined. The severity of VOD was determined according to the degree of multiple organ dysfunction. The incidence of VOD was similar in both groups (13/71, 18% vs. 14/91, 15%). All 14 patients in the second group who developed VOD showed decreased ATIII activity not more than 1 day prior to the clinical diagnosis of VOD. The resulting short duration of pre-emptive ATIII therapy failed to prevent VOD (OR 0.96). None of the patients (n=72) maintaining normal ATIII levels developed VOD. All 14 patients with VOD who received combined therapy achieved complete remission and 93 % (13/14) survived until day +100, compared to six survivors (46%) in the first group. Pre-emptive ATIII administration did not alter the incidence of VOD. Combination treatment with ATIII and defibrotide was safe and yielded excellent remission and survival rates.

  12. Progressive outer retinal necrosis associated with occlusive vasculitis in acquired immunodeficiency syndrome.

    PubMed

    Tseng, Chien-Chi; Chen, San-Ni; Hwang, Jiunn-Feng; Lin, Chun-Ju; Chen, Huan-Sheng

    2015-05-01

    A 45-year-old man, a case of acquired immunodeficiency syndrome, received a highly active antiretroviral therapy at the outpatient service for 4 years without regular follow-up. He experienced progressively blurred vision for 6 months and a cutaneous zoster on his back 3 months ago. He was diagnosed with progressive outer retinal necrosis by polymerase chain reaction-restriction fragment length polymorphism using an aqueous humor sample, which revealed an existence of varicella zoster virus. He was given a combination of systemic, intravitreal antiviral and a highly active antiretroviral therapy. Occlusive vasculitis, an unusual finding for progressive outer retinal necrosis, developed in both eyes 1 week after the secondary intravitreal injection. Unfortunately, his vision deteriorated to no light perception in both eyes within 2 weeks. Progressive outer retinal necrosis is characterized clinically as showing minimal or no inflammation in the aqueous and vitreous humors, absence of retinal vasculitis, and patches of yellowish spots located deep in the retina. Physicians should pay attention to this rare case of progressive outer retinal necrosis associated occlusive vasculitis with very poor prognosis in spite of aggressive treatment. Copyright © 2015. Published by Elsevier B.V.

  13. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  14. A special role for binocular visual input during development and as a component of occlusion therapy for treatment of amblyopia.

    PubMed

    Mitchell, Donald E

    2008-01-01

    To review work on animal models of deprivation amblyopia that points to a special role for binocular visual input in the development of spatial vision and as a component of occlusion (patching) therapy for amblyopia. The studies reviewed employ behavioural methods to measure the effects of various early experiential manipulations on the development of the visual acuity of the two eyes. Short periods of concordant binocular input, if continuous, can offset much longer daily periods of monocular deprivation to allow the development of normal visual acuity in both eyes. It appears that the visual system does not weigh all visual input equally in terms of its ability to impact on the development of vision but instead places greater weight on concordant binocular exposure. Experimental models of patching therapy for amblyopia imposed on animals in which amblyopia had been induced by a prior period of early monocular deprivation, indicate that the benefits of patching therapy may be only temporary and decline rapidly after patching is discontinued. However, when combined with critical amounts of binocular visual input each day, the benefits of patching can be both heightened and made permanent. Taken together with demonstrations of retained binocular connections in the visual cortex of monocularly deprived animals, a strong argument is made for inclusion of specific training of stereoscopic vision for part of the daily periods of binocular exposure that should be incorporated as part of any patching protocol for amblyopia.

  15. Overuse injuries: tendinopathies, stress fractures, compartment syndrome, and shin splints.

    PubMed

    Wilder, Robert P; Sethi, Shikha

    2004-01-01

    Approximately 50% of all sports injuries are secondary to overuse and result from repetitive microtrauma that causes local tissue damage. Injuries are most likely with changes in mode, intensity, or duration of training and can accumulate before symptoms appear. Intrinsic factors contributing to injuries are individual bio-mechanical abnormalities such as malalignments, muscle imbalance, inflexibility, weakness, and instability. Contributing extrinsic (avoidable) factors include poor technique, improper equipment, and improper changes in duration or frequency of activity. Injuries are often related to biomechanical abnormalities removed from the specific injury site, requiring evaluation of the entire kinetic chain. This article discusses common overuse injuries of the lower leg, ankle, and foot: tendinopathies, stress fractures, chronic exertional compartment syndrome, and shin splints.

  16. Application of photogrammetry for analysis of occlusal contacts.

    PubMed

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Central retinal artery occlusion - rethinking retinal survival time.

    PubMed

    Tobalem, Stephan; Schutz, James S; Chronopoulos, Argyrios

    2018-04-18

    The critical time from onset of complete occlusion of the central retinal artery (CRA) to functionally significant inner retinal infarction represents a window of opportunity for treatment and also has medical-legal implications, particularly when central retinal artery occlusion (CRAO) complicates therapeutic interventions. Here, we review the evidence for time to infarction from complete CRAO and discuss the implications of our findings. A Medline search was performed using each of the terms "central retinal artery occlusion", "retinal infarction", "retinal ischemia", and "cherry red spot" from 1970 to the present including articles in French and German. All retrieved references as well as their reference lists were screened for relevance. An Internet search using these terms was also performed to look for additional references. We find that the experimental evidence showing that inner retinal infarction occurs after 90-240 min of total CRAO, which is the interval generally accepted in the medical literature and practice guidelines, is flawed in important ways. Moreover, the retinal ganglion cells, supplied by the CRA, are part of the central nervous system which undergoes infarction after non-perfusion of 12-15 min or less. Retinal infarction is most likely to occur after only 12-15 min of complete CRAO. This helps to explain why therapeutic maneuvers for CRAO are often ineffective. Nevertheless, many CRAOs are incomplete and may benefit from therapy after longer intervals. To try to avoid retinal infarcton from inadvertent ocular compression by a headrest during prone anesthesia, the eyes should be checked at intervals of less than 15'.

  18. Posttraumatic cerebral infarction due to progressive occlusion of the internal carotid artery after minor head injury in childhood: a case report.

    PubMed

    Matsumoto, Hiroaki; Kohno, Kanehisa

    2011-07-01

    Although minor head injury in childhood is a common occurrence and usually no complications, posttraumatic cerebral infarction has rarely been reported. Such infarction is characterized by occlusion of the lateral lenticulostriate artery. The authors report an atypical case of posttraumatic occlusion of the internal carotid artery (ICA) after minor head injury in childhood. A healthy 16-year-old boy was hit on the head by a pitch while playing baseball. He developed a transient ischemic attack involving the left extremities 15 min after the accident. Initial magnetic resonance imaging revealed neither hemorrhage nor infarction, and MR angiography demonstrated mild stenosis of the right carotid fork. Conservative therapy was started. However, 24 h after the accident, he suddenly developed left hemiparesis. Emergent neuroimaging demonstrated progressive occlusion of the supraclinoid portion of the right ICA and cerebral infarction of the deep white matter in the right frontal lobe. The hemiparesis deteriorated and the infarction area continued to expand on a daily. The patient underwent emergent superficial temporally artery-middle cerebral artery (STA-MCA) bypass. Intraoperative observation demonstrated that the supraclinoid portion of the right ICA was not thrombosed but pale with low tension and did not appear dissected. He fully recovered by 2 weeks after the operation. Postoperative investigations showed gradual improvement of the ICA occlusion. Minor head injury can cause cerebral infarction in childhood, although this is rare. If conservative therapy cannot prevent progressive cerebral infarction, STA-MCA bypass should be considered in case of the ICA occlusion.

  19. [Evaluation of visual acuity in a historical cohort of 137 patients treated for amblyopia by occlusion 30-35 years ago].

    PubMed

    Simonsz-Tóth, B; Loudon, S E; van Kempen-du Saar, H; van de Graaf, E S; Groenewoud, J H; Simonsz, H J

    2007-01-01

    Opinions differ on the course of the visual acuity in the amblyopic eye after cessation of occlusion therapy. This study evaluated visual acuity in a historical cohort treated for amblyopia with occlusion therapy 30-35 years ago. Between 1968 and 1975, 1250 patients had been treated by the orthoptist in the Waterland Hospital in Purmerend, The Netherlands. Of these, 471 received occlusion treatment for amblyopia (prevalence 5.0%, after comparison with the local birth rate). We were able to contact 203 of these patients, 137 were orthoptically re-examined in 2003. We correlated the current visual acuity with the cause of amblyopia, the age at start and end of treatment, the visual acuity at start and end of treatment, fixation, binocular vision and refractive errors. Mean age at the start of treatment was 5.4 +/- 1.9 years, 7.4 +/- 1.7 years at the end and 37 +/- 2.7 years at follow-up. Current visual acuity in the amblyopic eye was correlated with a low visual acuity at the start (p < 0.0001) and end (p < 0.0001) of occlusion therapy, an eccentric fixation (p < 0.0001), and the cause of amblyopia (p = 0.005). At the end of the treatment, patients with a strabismic amblyopia (n = 98) had a visual acuity in the amblyopic eye of 0.29 logMAR +/- 0.3, and in 2003 0.27 +/- 0.3 logMAR. In patients with an anisometropic amblyopia (> 1 D, n = 16) visual acuity had decreased from 0.17 +/- 0.23 logMAR to 0.21 logMAR +/- 0.23. In patients with both strabismic and anisometropic amblyopia (n = 23), visual acuity had decreased from 0.52 logMAR +/- 0.54 to 0.65 logMAR +/- 0.54. Overall, acuity had decreased in 54 patients (39%) after cessation of treatment. Of these, 18 patients had an acuity decrease to less than 50% of their acuity at the end of treatment. In 15 of these 18 patients anisohypermetropia had increased. A decrease in visual acuity after cessation of occlusion therapy occurred in patients with a combined cause of amblyopia or with an increase in anisohypermetropia.

  20. Occlusal wear and occlusal condition in a convenience sample of young adults.

    PubMed

    Van't Spijker, A; Kreulen, C M; Bronkhorst, E M; Creugers, N H J

    2015-01-01

    To study progression of tooth wear quantitatively in a convenient sample of young adults and to assess possible correlations with occlusal conditions. Twenty-eight dental students participated in a three-year follow up study on tooth wear. Visible wear facets on full arch gypsum casts were assessed using a flatbed scanner and measuring software. Regression analyses were used to assess possible associations between the registered occlusal conditions 'occlusal guidance scheme', 'vertical overbite', 'horizontal overbite', 'depth of sagittal curve', 'canine Angle class relation', 'history of orthodontic treatment', and 'self-reported grinding/clenching' (independent variables) and increase of wear facets (dependent variable). Mean increase in facet surface areas ranged from 1.2 mm2 (premolars, incisors) to 3.4 mm2 (molars); the relative increase ranged from 15% to 23%. Backward regression analysis showed no significant relation for 'group function', 'vertical overbite', 'depth of sagittal curve', 'history of orthodontic treatment' nor 'self-reported clenching. The final multiple linear regression model showed significant associations amongst 'anterior protected articulation' and 'horizontal overbite' and increase of facet surface areas. For all teeth combined, only 'anterior protected articulation' had a significant effect. 'Self reported grinding' did not have a significant effect (p>0.07). In this study 'anterior protected articulation' and 'horizontal overbite', were significantly associated with the progression of tooth wear. Self reported grinding was not significantly associated with progression of tooth wear. Occlusal conditions such as anterior protected articulation and horizontal overbite seem to have an effect on the progression of occlusal tooth wear in this convenient sample of young adults. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Detecting natural occlusion boundaries using local cues

    PubMed Central

    DiMattina, Christopher; Fox, Sean A.; Lewicki, Michael S.

    2012-01-01

    Occlusion boundaries and junctions provide important cues for inferring three-dimensional scene organization from two-dimensional images. Although several investigators in machine vision have developed algorithms for detecting occlusions and other edges in natural images, relatively few psychophysics or neurophysiology studies have investigated what features are used by the visual system to detect natural occlusions. In this study, we addressed this question using a psychophysical experiment where subjects discriminated image patches containing occlusions from patches containing surfaces. Image patches were drawn from a novel occlusion database containing labeled occlusion boundaries and textured surfaces in a variety of natural scenes. Consistent with related previous work, we found that relatively large image patches were needed to attain reliable performance, suggesting that human subjects integrate complex information over a large spatial region to detect natural occlusions. By defining machine observers using a set of previously studied features measured from natural occlusions and surfaces, we demonstrate that simple features defined at the spatial scale of the image patch are insufficient to account for human performance in the task. To define machine observers using a more biologically plausible multiscale feature set, we trained standard linear and neural network classifiers on the rectified outputs of a Gabor filter bank applied to the image patches. We found that simple linear classifiers could not match human performance, while a neural network classifier combining filter information across location and spatial scale compared well. These results demonstrate the importance of combining a variety of cues defined at multiple spatial scales for detecting natural occlusions. PMID:23255731

  2. Endovascular Management of Central Retinal Arterial Occlusion.

    PubMed

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  3. Marvels, mysteries, and misconceptions of vascular compensation to peripheral artery occlusion.

    PubMed

    Ziegler, Matthew A; Distasi, Matthew R; Bills, Randall G; Miller, Steven J; Alloosh, Mouhamad; Murphy, Michael P; Akingba, A George; Sturek, Michael; Dalsing, Michael C; Unthank, Joseph L

    2010-01-01

    Peripheral arterial disease is a major health problem and there is a significant need to develop therapies to prevent its progression to claudication and critical limb ischemia. Promising results in rodent models of arterial occlusion have generally failed to predict clinical success and led to questions of their relevance. While sub-optimal models may have contributed to the lack of progress, we suggest that advancement has also been hindered by misconceptions of the human capacity for compensation and the specific vessels which are of primary importance. We present and summarize new and existing data from humans, Ossabaw miniature pigs, and rodents which provide compelling evidence that natural compensation to occlusion of a major artery (i) may completely restore perfusion, (ii) occurs in specific pre-existing small arteries, rather than the distal vasculature, via mechanisms involving flow-mediated dilation and remodeling (iii) is impaired by cardiovascular risk factors which suppress the flow-mediated mechanisms and (iv) can be restored by reversal of endothelial dysfunction. We propose that restoration of the capacity for flow-mediated dilation and remodeling in small arteries represents a largely unexplored potential therapeutic opportunity to enhance compensation for major arterial occlusion and prevent the progression to critical limb ischemia in the peripheral circulation.

  4. Marvels, Mysteries, and Misconceptions of Vascular Compensation to Peripheral Artery Occlusion

    PubMed Central

    ZIEGLER, MATTHEW A.; DISTASI, MATTHEW R.; BILLS, RANDALL G.; MILLER, STEVEN J.; ALLOOSH, MOUHAMAD; MURPHY, MICHAEL P.; AKINGBA, A. GEORGE; STUREK, MICHAEL; DALSING, MICHAEL C.; UNTHANK, JOSEPH L.

    2010-01-01

    Peripheral arterial disease is a major health problem and there is a significant need to develop therapies to prevent its progression to claudication and critical limb ischemia. Promising results in rodent models of arterial occlusion have generally failed to predict clinical success and led to questions of their relevance. While sub-optimal models may have contributed to the lack of progress, we suggest that advancement has also been hindered by misconceptions of the human capacity for compensation and the specific vessels which are of primary importance. We present and summarize new and existing data from humans, Ossabaw miniature pigs, and rodents which provide compelling evidence that natural compensation to occlusion of a major artery (i) may completely restore perfusion, (ii) occurs in specific pre-existing small arteries, rather than the distal vasculature, via mechanisms involving flow-mediated dilation and remodeling (iii) is impaired by cardiovascular risk factors which suppress the flow-mediated mechanisms and (iv) can be restored by reversal of endothelial dysfunction. We propose that restoration of the capacity for flow-mediated dilation and remodeling in small arteries represents a largely unexplored potential therapeutic opportunity to enhance compensation for major arterial occlusion and prevent the progression to critical limb ischemia in the peripheral circulation. PMID:20141596

  5. Effectiveness of physical and occupational therapy on pain, function and quality of life in patients with trapeziometacarpal osteoarthritis - A systematic review and meta-analysis.

    PubMed

    Aebischer, Bernhard; Elsig, Simone; Taeymans, Jan

    2016-03-01

    Trapeziometacarpal osteoarthritis is associated with more pain and restrictions than other hand osteoarthritis due to the functional importance of the thumb. While the effectiveness of surgical and pharmacological interventions has been widely examined, there is a lack of specific evidence about conservative non-pharmacological trapeziometacarpal osteoarthritis therapies. The objective of this systematic review was to provide evidence-based knowledge on the effectiveness of physiotherapy and occupational therapy on pain, function and quality of life. A literature search of Medline, CINAHL, PEDro, OTseeker, EMB Dare Cochrane Database of Systematic Reviews and Cochrane CENTRAL was performed. Randomized and quasi-randomized controlled trials and corresponding systematic reviews, observational studies, pragmatic studies and case-control studies were included. The risk of bias was assessed. Out of 218 studies, 27 were retained. A narrative summary and a series of meta-analyses were performed. Concerning pain reduction, the meta-analysis showed parity of pre-fabricated neoprene and custom-made thermoplastic splints: standardized mean difference (SMD) -0.01 (95%CI -0.43, 0.40) (p=0.95). Multimodal interventions are more effective on pain compared to single interventions: standardized mean difference -3.16 (95%CI -5.56, -0.75) ( p  = 0.01). Physical and occupational therapy-related interventions, especially multimodal interventions, seem to be effective to treat pain in patients with trapeziometacarpal osteoarthritis. Pre-fabricated neoprene splints and custom-made thermoplastic splints may reduce pain equally. Single interventions seem not to be effective. Significant evidence for effectiveness on function and quality of life could not be found.

  6. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    PubMed Central

    2010-01-01

    Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p < 0.001). The changes in the mean HOP-BPOP differences on the x-axis (mediolateral) and the y-axis (anteroposterior) were significant (p < 0.05), whereas the change on the z-axis (superoinferior) was not significant (p > 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167

  7. Endovascular revascularization results in IMS III: intracranial ICA and M1 occlusions.

    PubMed

    Tomsick, Thomas A; Yeatts, Sharon D; Liebeskind, David S; Carrozzella, Janice; Foster, Lydia; Goyal, Mayank; von Kummer, Ruediger; Hill, Michael D; Demchuk, Andrew M; Jovin, Tudor; Yan, Bernard; Zaidat, Osama O; Schonewille, Wouter; Engelter, Stefan; Martin, Renee; Khatri, Pooja; Spilker, Judith; Palesch, Yuko Y; Broderick, Joseph P

    2015-11-01

    Interventional Management of Stroke III did not show that combining IV recombinant tissue plasminogen activator (rt-PA) with endovascular therapies (EVTs) is better than IV rt-PA alone. To report efficacy and safety results for EVT of intracranial internal carotid artery (ICA) and middle cerebral artery trunk (M1) occlusion. Five revascularization methods for persistent occlusions after IV rt-PA treatment were evaluated for prespecified primary and secondary endpoints, after accounting for differences in key baselines variables using propensity scores. Revascularization was scored using the arterial occlusive lesion (AOL) and the modified Thrombolysis in Cerebral Ischemia (mTICI) scores. EVT of 200 subjects with intracranial ICA or M1 occlusion resulted in 81.5% AOL 2-3 recanalization, in addition to 76% mTICI 2-3 and 42.5% mTICI 2b-3 reperfusion. Adverse events included symptomatic intracranial hemorrhage (SICH) (8.0%), vessel perforations (1.5%), and new emboli (14.9%). EVT techniques used were standard microcatheter n=51; EKOS n=14; Merci n=77; Penumbra n=39; Solitaire n=4; multiple n=15. Good clinical outcome was associated with both TICI 2-3 and TICI 2b-3 reperfusion. Neither modified Rankin scale (mRS) 0-2 (28.5%), nor 90-day mortality (28.5%), nor asymptomatic ICH (36.0%) differed among revascularization methods after propensity score adjustment for subjects with intracranial ICA or M1 occlusion. Good clinical outcome was associated with good reperfusion for ICA and M1 occlusion. No significant differences in efficacy or safety among revascularization methods were demonstrated after adjustment. Lack of high-quality reperfusion, adverse events, and prolonged time to treatment contributed to lower-than-expected mRS 0-2 outcomes and study futility compared with IV rt-PA. NCT00359424. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhudesai, V., E-mail: v_prabhudesai@hotmail.com; Mitra, K.; West, D. J.

    2003-09-15

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome.

  9. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  10. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  11. Sinusoidal Obstruction Syndrome (Hepatic Veno-Occlusive Disease)

    PubMed Central

    Fan, Cathy Q.; Crawford, James M.

    2014-01-01

    Hepatic sinusoidal obstruction syndrome (SOS) is an obliterative venulitis of the terminal hepatic venules, which in its more severe forms imparts a high risk of mortality. SOS, also known as veno-occlusive disease (VOD), occurs as a result of cytoreductive therapy prior to hematopoietic stem cell transplantation (HSCT), following oxaliplatin-containing adjuvant or neoadjuvant chemotherapy for colorectal carcinoma metastatic to the liver and treated by partial hepatectomy, in patients taking pyrrolizidine alkaloid-containing herbal remedies, and in other particular settings such as the autosomal recessive condition of veno-occlusive disease with immunodeficiency (VODI). A central pathogenic event is toxic destruction of hepatic sinusoidal endothelial cells (SEC), with sloughing and downstream occlusion of terminal hepatic venules. Contributing factors are SEC glutathione depletion, nitric oxide depletion, increased intrahepatic expression of matrix metalloproteinases and vascular endothelial growth factor (VEGF), and activation of clotting factors. The clinical presentation of SOS includes jaundice, development of right upper-quadrant pain and tender hepatomegaly, ascites, and unexplained weight gain. Owing to the potentially critical condition of these patients, transjugular biopsy may be the preferred route for liver biopsy to exclude other potential causes of liver dysfunction and to establish a diagnosis of SOS. Treatment includes rigorous fluid management so as to avoid excessive fluid overload while avoiding too rapid diuresis or pericentesis, potential use of pharmaceutics such as defibrotide, coagulolytic agents, or methylprednisolone, and liver transplantation. Proposed strategies for prevention and prophylaxis include reduced-intensity conditioning radiation for HSCT, treatment with ursodeoxycholic acid, and inclusion of bevacizumab with oxaliplatin-based chemotherapeutic regimes. While significant progress has been made in understanding the pathogenesis

  12. Acute left main coronary artery occlusion

    PubMed Central

    Burgazli, K. Mehmet; Bilgin, Mehmet; Soydan, Nedim; Chasan, Ridvan; Erdogan, Ali

    2013-01-01

    The treatment of an acute left main coronary artery occlusion still poses a challenge. In this case report we present a 50-year-old patient with an acute occlusion of the left main artery. After a successful angioplasty without “stenting” due to the complexity of the stenosis the patient underwent a successful bypass surgery. We discuss the therapeutic options of acute left main occlusion regarding medical, interventional and surgical options. PMID:24353543

  13. The effect of polarized polychromatic noncoherent light (bioptron) therapy on patients with carpal tunnel syndrome.

    PubMed

    Raeissadat, Seyed Ahmad; Rayegani, Seyed Mansoor; Rezaei, Sajad; Sedighipour, Leyla; Bahrami, Mohammad Hasan; Eliaspour, Dariush; Karimzadeh, Afshin

    2014-01-01

    To study the effects of Polarized Polychromatic Noncoherent Light (Bioptron) therapy on patients with carpal tunnel syndrome (CTS). This study was designed as a randomized clinical trial. Forty four patients with mild or moderate CTS (confirmed by clinical and electrodiagnostic studies) were assigned randomly into two groups (intervention and control goups). At the beginning of the study, both groups received wrist splinting for 8 weeks. Bioptron light was applied for the intervention group (eight sessions, for 3/weeks). Bioptron was applied perpendicularly to the wrist from a 10 centimeter sdistance. Pain severity and electrodiagnostic measurements were compared from before to 8 weeks after initiating each treatment. Eight weeks after starting the treatments, the mean of pain severity based on Visual Analogue Scale (VAS) scores decreased significantly in both groups. Median Sensory Nerve Action Potential (SNAP) latency decreased significantly in both groups. However, other electrophysiological findings (median Compound Motor Action Potential (CMAP) latency and amplitude, also SNAP amplitude) did not change after the therapy in both groups. There was no meaningful difference between two groups regarding the changes in the pain severity. Bioptron with the above mentioned parameters led to therapeutic effects equal to splinting alone in patients with carpal tunnel syndrome. However, applying Bioptron with different therapeutic protocols and light parameters other than used in this study, perhaps longer duration of therapy and long term assessment may reveal different results favoring Bioptron therapy.

  14. The Effect of Polarized Polychromatic Noncoherent Light (Bioptron) Therapy on Patients with Carpal Tunnel Syndrome

    PubMed Central

    Raeissadat, Seyed Ahmad; Rayegani, Seyed Mansoor; Rezaei, Sajad; Bahrami, Mohammad Hasan; Eliaspour, Dariush; Karimzadeh, Afshin

    2014-01-01

    Introduction: To study the effects of Polarized Polychromatic Noncoherent Light (Bioptron) therapy on patients with carpal tunnel syndrome (CTS). Methods: This study was designed as a randomized clinical trial. Forty four patients with mild or moderate CTS (confirmed by clinical and electrodiagnostic studies) were assigned randomly into two groups (intervention and control goups). At the beginning of the study, both groups received wrist splinting for 8 weeks. Bioptron light was applied for the intervention group (eight sessions, for 3/weeks). Bioptron was applied perpendicularly to the wrist from a 10 centimeter sdistance. Pain severity and electrodiagnostic measurements were compared from before to 8 weeks after initiating each treatment. Results: Eight weeks after starting the treatments, the mean of pain severity based on Visual Analogue Scale (VAS) scores decreased significantly in both groups. Median Sensory Nerve Action Potential (SNAP) latency decreased significantly in both groups. However, other electrophysiological findings (median Compound Motor Action Potential (CMAP) latency and amplitude, also SNAP amplitude) did not change after the therapy in both groups. There was no meaningful difference between two groups regarding the changes in the pain severity. Conclusion: Bioptron with the above mentioned parameters led to therapeutic effects equal to splinting alone in patients with carpal tunnel syndrome. However, applying Bioptron with different therapeutic protocols and light parameters other than used in this study, perhaps longer duration of therapy and long term assessment may reveal different results favoring Bioptron therapy. PMID:25606338

  15. Therapies for Macular Edema Associated with Branch Retinal Vein Occlusion: A Report by the American Academy of Ophthalmology.

    PubMed

    Ehlers, Justis P; Kim, Stephen J; Yeh, Steven; Thorne, Jennifer E; Mruthyunjaya, Prithvi; Schoenberger, Scott D; Bakri, Sophie J

    2017-09-01

    To evaluate the available evidence on the ocular safety and efficacy of current therapeutic alternatives for the management of macular edema (ME) secondary to branch retinal vein occlusion (BRVO). Literature searches were last conducted on January 31, 2017, in PubMed with no date restrictions and limited to articles published in English, and in the Cochrane Database without language limitations. The searches yielded 321 citations, of which 109 were reviewed in full text and 27 were deemed appropriate for inclusion in this assessment. The panel methodologist assigned ratings to the selected studies according to the level of evidence. Level I evidence was identified in 10 articles that addressed anti-vascular endothelial growth factor (VEGF) pharmacotherapies for ME, including intravitreal bevacizumab (5), aflibercept (2), and ranibizumab (4). Level I evidence was identified in 6 studies that examined intravitreal corticosteroids, including triamcinolone (4) and the dexamethasone implant (2). Level I evidence also was available for the role of macular grid laser photocoagulation (7) and scatter peripheral laser surgery (1). The inclusion of level II and level III studies was limited given the preponderance of level I studies. The number of studies on combination therapy is limited. Current level I evidence suggests that intravitreal pharmacotherapy with anti-VEGF agents is effective and safe for ME secondary to BRVO. Prolonged delay in treatment is associated with less improvement in visual acuity (VA). Level I evidence also indicates that intravitreal corticosteroids are effective and safe for the management of ME associated with BRVO; however, corticosteroids are associated with increased potential ocular side effects (e.g., elevated intraocular pressure, cataracts). Laser photocoagulation remains a safe and effective therapy, but VA results lag behind the results for anti-VEGF therapies. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier

  16. Length of occlusion predicts recanalization and outcome after intravenous thrombolysis in middle cerebral artery stroke.

    PubMed

    Rohan, Vladimir; Baxa, Jan; Tupy, Radek; Cerna, Lenka; Sevcik, Petr; Friesl, Michal; Polivka, Jiri; Polivka, Jiri; Ferda, Jiri

    2014-07-01

    The length of large vessel occlusion is considered a major factor for therapy in patients with ischemic stroke. We used 4D-CT angiography evaluation of middle cerebral artery occlusion in prediction of recanalization and favorable clinical outcome and after intravenous thrombolysis (IV-tPA). In 80 patients treated with IV-tPA for acute complete middle cerebral artery/M1 occlusion determined using CT angiography and temporal maximum intensity projection, calculated from 4D-CT angiography, the length of middle cerebral artery proximal stump, occlusion in M1 or M1 and M2 segment were measured. Univariate and multivariate analyses were performed to define independent predictors of successful recanalization after 24 hours and favorable outcome after 3 months. The length of occlusion was measureable in all patients using temporal maximum intensity projection. Recanalization thrombolysis in myocardial infarction 2 to 3 was achieved in 37 individuals (46%). The extension to M2 segment as a category (odds ratio, 4.58; 95% confidence interval, 1.39-15.05; P=0.012) and the length of M1 segment occlusion (odds ratio, 0.82; 95% confidence interval, 0.73-0.92; P=0.0007) with an optimal cutoff value of 12 mm (sensitivity 0.67; specificity 0.71) were significant independent predictors of recanalization. Favorable outcome (modified Rankin scale 0-2) was achieved in 25 patients (31%), baseline National Institutes of Health Stroke Scale (odds ratio, 0.82; 95% confidence interval, 0.72-0.93; P=0.003) and the length of occlusion M1 in segment (odds ratio, 0.79; 95% confidence interval, 0.69-0.91; P=0.0008) with an optimal cutoff value of 11 mm (sensitivity 0.74; specificity 0.76) were significant independent predictors of favorable outcome. The length of middle cerebral artery occlusion is an independent predictor of successful IV-tPA treatment. © 2014 American Heart Association, Inc.

  17. Real-Time Color-Doppler Guidance of HIFU for the Selective Avoidance or Occlusion of Blood Vessels

    NASA Astrophysics Data System (ADS)

    Rabkin, Brian A.; Zderic, Vesna; Vaezy, Shahram

    2005-03-01

    High-intensity focused ultrasound (HIFU) has been shown to effectively occlude blood vessels deep within tissue. The objective of the current study was to synchronize HIFU and color-Doppler ultrasound (US) for the real-time visualization of flow within blood vessels during HIFU treatment. The excitation of the HIFU was synchronized with the color-Doppler imager by collecting the excitation pulses of one of the elements of either a curved array intracavitary (C 9-5) or an intraoperative (CL 10-5) imaging probe. The collected excitation pulse was converted into a TTL-high pulse, which was delayed and gated to time the excitation duration and location of the HIFU pulse with respect to each imaging frame. The single pulse was used to drive a 3.2 MHz concave HIFU transducer (focal length of 3.5 cm, f-number 1) while the US imager was not collecting RF signals from the treatment region of the US image. The feasibility of the system was demonstrated in vivo by the selective ablation of tissue adjacent to, or the occlusion of, large vessels (including the femoral artery) both transcutaneously and interoperatively in the rabbit and pig. For the occlusion of vessels, the HIFU focus was placed immediately distal (with respect to the transducer) to the vessel at a depth of 2-2.5 cm. HIFU was applied at in situ intensities of 1000-2000 W/cm2, at a duty cycle of 50-75%, and a HIFU pulse repetition frequency (set by the US image frame rate) of 6-18 Hz. During each HIFU exposure, the HIFU pulse resulted in color interference bands running vertically within the color-Doppler window. Through the synchronization of the US imager with the HIFU excitation, the location and duration of the interference bands were set outside the treatment region within each image frame. This provided the operator with a clear view of the HIFU treatment site during therapy. Gross assessment showed necrosis of the tissue surrounding the HIFU treated vessel and occlusion of vessels up to 4 mm in diameter

  18. Inheritance of Occlusal Topography: A Twin Study

    PubMed Central

    Su, C-Y.; Corby, P.M.; Elliot, M.A.; Studen-Pavlovich, D.A.; Ranalli, D.N.; Rosa, B.; Wessel, J.; Schork, N.J.; Hart, T.C.; Bretz, W.A.

    2011-01-01

    Aim This was to determine the relative contribution of genetic factors on the morphology of occlusal surfaces of mandibular primary first molars by employing the twin study model. Methods The occlusal morphology of mandibular primary first molar teeth from dental casts of 9 monozygotic (MZ) twin pairs and 12 dizygotic (DZ) twin pairs 4 to 7 years old, were digitized by contact-type three-dimensional (3D) scanner. To compare the similarity of occlusal morphology between twin sets, each twin pair of occlusal surfaces was superimposed to establish the best fit by using computerized least squared techniques. Heritability was computed using a variance component model, adjusted for age and gender. Results DZ pairs demonstrated a greater degree of occlusal morphology variance. The total amount of difference in surface overlap was 0.0508 mm (0.0018 (inches) for the MZ (n=18) sample and 0.095 mm (0.0034 inches) for the DZ (n=24) sample and were not statistically significant (p=0.2203). The transformed mean differences were not statistically significantly different (p=0.2203). Heritability estimates of occlusal surface areas for right and left mandibular primary first molars were 97.5% and 98.2% (p<0.0001), respectively. Conclusions Occlusal morphology of DZ twin pairs was more variable than that of MZ twin pairs. Heritability estimates revealed that genetic factors strongly influence occlusal morphology of mandibular primary first molars. PMID:18328234

  19. Rapidly progressive pulmonary veno-occlusive disease in an infant with Down syndrome.

    PubMed

    Muneuchi, Jun; Oda, Shinichiro; Shimizu, Daisuke

    2017-09-01

    A 4-month-old girl with Down syndrome showed unexpected deterioration of pulmonary hypertension. Despite aggressive pulmonary vasodilation therapy, the patient died at 5 months of age. Lung autopsy showed that the pulmonary veins were obliterated by intimal fibrous thickening, and the media of the veins was arterialised with an increase in elastic fibres. Pulmonary veno-occlusive disease should be considered in the management of individuals with Down syndrome.

  20. Oestradiol supplement minimises coronary occlusion-induced myocardial infarction and ventricular dysfunction in oophorectomised female rats.

    PubMed

    Zheng, Xiao-Pu; Ma, Ai-Qun; Dong, An-Ping; Wang, Shun; Jiang, Wen-Hui; Wang, Ting-Zhong; Fan, Fen-Ling; Ling, Shanhong

    2011-09-15

    Endogenous oestrogen deficiency after menopause is associated with high risk of acute cardiac events and the protection of exogenous oestrogen supplements remains uncertain. This study investigates whether oestrogen therapy protects the heart from ischemic injury in oophorectomised rats. Sexually mature female Sprague-Dawley rats (6 for each group) with bilateral oophorectomy underwent selective ligation (occlusion) of left coronary artery for 4 weeks. 17β-oestradiol (E2) supplements (10 μg, i.m., every other day) were started before (preventive-therapeutic supplement) or after coronary occlusion (therapeutic supplement). In oophorectomised rats plasma levels of E2 declined from 1301 ± 80 to 196 ± 48 pmol/L (p<0.01) and cardiac expression of oestrogen receptors (ER) decreased by ∼60%. E2 supplements recovered the ER expression. Selective ligation of left coronary led myocardial infarction in the left ventricle, with an increase in plasma cardiac troponin I (cTn-I), decrease in systolic blood pressure (SBP), and reduction of left ventricular pressures. Preventive-therapeutic but not therapeutic E2 supplement reduced cTn-I levels (from 21.9 ± 2.0 to 6.0 ± 0.3 ng/mL, p<0.01), minimised infarction (from 37.0 ± 1.2% to 18.1 ± 2.3%, p<0.05), increased SBP (from 82 ± 4.2 to 97 ± 4.4mm Hg, p<0.05), and improved left ventricular end pressures in the oophorectomised rats following coronary occlusion. Postmenopausal (ooporectomised) oestrogen supplement commenced before establishment of myocardial ischemia minimises myocardial infarction and ventricular dysfunction following the coronary artery occlusion. Cellular and molecular mechanisms underlying the cardiac protection of oestrogen therapy remain unclear, in which activation of cardiac ER expression and increasing in circulating CD90(+) stem cells may be involved. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Strategy for the management of macular edema in retinal vein occlusion: the European VitreoRetinal Society macular edema study.

    PubMed

    Adelman, Ron A; Parnes, Aaron J; Bopp, Silvia; Saad Othman, Ihab; Ducournau, Didier

    2015-01-01

    To compare the efficacy of different therapies in the treatment of macular edema associated with retinal vein occlusion (RVO). This is a nonrandomized, multicenter collaborative study. 86 retina specialists from 29 countries provided clinical information, including choice of treatment and outcome, on 2,603 patients with macular edema including 738 cases of RVO. Reported data included the type and number of treatments performed, visual acuities, and other clinical and diagnostic findings. The mean increase in visual acuity and mean number of treatments performed. 358 cases of central retinal vein occlusion (CRVO) and 380 cases of branch retinal vein occlusion (BRVO) were included in this investigation. Taking all RVO cases together, pars plana vitrectomy with internal limiting membrane (ILM) peeling alone resulted in an improvement in vision greater than other therapies. Those treated with intravitreal antivascular endothelial growth factor (anti-VEGF) injection alone showed the second greatest improvement in vision. Dexamethasone intravitreal implant alone and intravitreal triamcinolone alone both resulted in modest visual gains. In the treatment of macular edema in RVO, vitrectomy with ILM peeling may achieve visual improvement and may be a good option for certain cases. Anti-VEGF injection is the most effective of the nonsurgical treatments.

  2. Patient-specific interface pressure case study at transradial prosthetic socket: comparison trials between ICRC polypropylene socket and air splint socket.

    PubMed

    Abd Razak, Nasrul A; Abu Osman, Noor A; Ali, Sadeeq A; Gholizadeh, Hossein

    2016-01-15

    While considering how important the interface between the amputees with the prostheses socket, we have carried out research to compare the gradient pressure occur at the interface socket that may lead to the discomforting effects to the user using common ICRC polypropylene socket and air splint socket. Not Applicable SETTING: Not Applicable POPULATION: The subject was a 23 year old who suffered a traumatic defect on the right arm caused by higher electrical volt. F-Socket sensors have been used to measure dynamic socket interface pressure for the transradial amputee wearer during static and dynamic movements. The printed circuit with a thickness of 0.18 mm is equipped between the socket and the surface of the residual limb. Two F-Socket sensor is required to cover the entire socket surface attached to the residual limb. The average of 10 trials made on prosthetic user using both type of sockets for static and dynamic movements was recorded. The pressure gradient shows that the circumference of the socket interface for the ICRC polypropylene socket gives the most pressure distributions to the amputees compared to the pressure gradient for the air splint socket. The pressure gradient for ICRC socket increased consistently when the user makes movements while for the air splint socket remain constantly. The specific interface pressure occur at the socket interface help in determine the comfort and pain of the socket design and improve the correlation between the user and the prosthesis.

  3. The lingual splint: an often forgotten method for fixating pediatric mandibular fractures.

    PubMed

    Binahmed, Abdulaziz; Sansalone, Claudio; Garbedian, Justin; Sándor, George K B

    2007-01-01

    Maxillofacial fractures are uncommon in the pediatric population, and their treatment is unique due to the psychological, physiological, developmental and anatomical characteristics of children. We present the case of a boy who was treated in an outpatient dental clinic using a lingual splint for the reduction, stabilization and fixation of a mandibular body fracture. This technique is a reliable, noninvasive procedure that dentists may consider in selected cases by referral to an oral and maxillofacial surgeon. It also limits the discomfort and morbidity that can be associated with maxillomandibular fixation or open reduction and internal fixation in pediatric patients.

  4. Percutaneous left atrial appendage occlusion – treatment outcomes and 6 months of follow-up – a single-center experience

    PubMed Central

    Karczewski, Michał; Skowronek, Radomir; Burysz, Marian; Fischer, Marcin; Anisimowicz, Lech; Demkow, Marcin; Konka, Marek; Ogorzeja, Wojciech

    2016-01-01

    Aim To present the results of treatment and evaluate 6 months of follow-up in a group of patients with non-valvular atrial fibrillation, who underwent the procedure of percutaneous left atrial appendage occlusion (PLAAO). Material and methods Percutaneous left atrial appendage occlusion was performed in 34 patients with non-valvular atrial fibrillation and contraindications for oral anticoagulation therapy. The risk of thromboembolic and bleeding complications was determined based on the CHA2DS2VASc and HAS-BLED scales. The Amplatzer Amulet system from St. Jude Medical was used. On the first postoperative day, all patients were started on double antiplatelet therapy with 75 mg/day of acetylsalicylic acid (ASA) and 75 mg/day of clopidogrel (CLO). On the 30th postoperative day, the efficacy of the antiplatelet therapy was assessed with impedance aggregometry using a Multiplate analyzer (Roche). Echocardiographic examinations were performed intraoperatively and on the first postoperative day; subsequently, follow-up examinations were conducted 1 and 6 months after the implantation. Results In all patients, proper occluder position was observed throughout the follow-up. No leakage or thrombi around the implants were found. No strokes or bleeding complications associated with the antiplatelet therapy were observed. Multiplate assessment of platelet activity was conducted in 20 out of 34 patients. The efficacy of ASA treatment was demonstrated in all patients; no response to clopidogrel treatment was observed in 5 out of 20 patients. One patient suffered from cardiac tamponade, which required the performance of full sternotomy. Local complications (hematomas of the inguinal region) were observed in 3 patients. One of the patients died for reasons unrelated to the procedure. Conclusions Percutaneous left atrial appendage occlusion is an effective procedure in patients with non-valvular atrial fibrillation and contraindications for chronic anticoagulation therapy. Further

  5. A randomized multicentre trial to compare revascularization with optimal medical therapy for the treatment of chronic total coronary occlusions.

    PubMed

    Werner, Gerald S; Martin-Yuste, Victoria; Hildick-Smith, David; Boudou, Nicolas; Sianos, Georgios; Gelev, Valery; Rumoroso, Jose Ramon; Erglis, Andrejs; Christiansen, Evald Høj; Escaned, Javier; di Mario, Carlo; Hovasse, Thomas; Teruel, Luis; Bufe, Alexander; Lauer, Bernward; Bogaerts, Kris; Goicolea, Javier; Spratt, James C; Gershlick, Anthony H; Galassi, Alfredo R; Louvard, Yves

    2018-05-02

    The clinical value of percutaneous coronary intervention (PCI) for chronic coronary total occlusions (CTOs) is not established by randomized trials. This study should compare the benefit of PCI vs. optimal medical therapy (OMT) on the health status in patients with at least one CTO. Three hundred and ninety-six patients were enrolled in a prospective randomized, multicentre, open-label, and controlled clinical trial to compare the treatment by PCI with OMT with a 2:1 randomization ratio. The primary endpoint was the change in health status assessed by the Seattle angina questionnaire (SAQ) between baseline and 12 months follow-up. Fifty-two percent of patients have multi-vessel disease in whom all significant non-occlusive lesions were treated before randomization. An intention-to-treat analysis was performed including 13.4% failed procedures in the PCI group and 7.3% cross-overs in the OMT group. At 12 months, a greater improvement of SAQ subscales was observed with PCI as compared with OMT for angina frequency [5.23, 95% confidence interval (CI) 1.75; 8.71; P = 0.003], and quality of life (6.62, 95% CI 1.78-11.46; P = 0.007), reaching the prespecified significance level of 0.01 for the primary endpoint. Physical limitation (P = 0.02) was also improved in the PCI group. Complete freedom from angina was more frequent with PCI 71.6% than OMT 57.8% (P = 0.008). There was no periprocedural death or myocardial infarction. At 12 months, major adverse cardiac events were comparable between the two groups. Percutaneous coronary intervention leads to a significant improvement of the health status in patients with stable angina and a CTO as compared with OMT alone. NCT01760083.

  6. A novel route of revascularization in basilar artery occlusion and review of the literature

    PubMed Central

    Morales, Alejandro; Parry, Phillip Vaughan; Jadhav, Ashutosh; Jovin, Tudor

    2015-01-01

    Ischemia of the basilar artery is one of the most devastating types of arterial occlusive disease. Despite treatment of basilar artery occlusions (BAO) with intravenous tissue plasminogen activator, antiplatelet agents, intra-arterial therapy or a combination, fatality rates remain high. Aggressive recanalization with mechanical thrombectomy is therefore often necessary to preserve life. When direct access to the basilar trunk is not possible, exploration of chronically occluded vessels through collaterals with angioplasty and stenting creates access for manual aspiration. We describe the first report of retrograde vertebral artery (VA) revascularization using thyrocervical collaterals for anterograde mechanical aspiration of a BAO followed by stenting of the chronically occluded VA origin. Our novel retrograde–anterograde approach resulted in resolution of the patient's clinical stroke syndrome. PMID:26055597

  7. Neuromuscular dentistry: Occlusal diseases and posture.

    PubMed

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture.

  8. Subdissociative intranasal ketamine plus standard pain therapy versus standard pain therapy in the treatment of paediatric sickle cell disease vaso-occlusive crises in resource-limited settings: study protocol for a randomised controlled trial.

    PubMed

    Young, James R; Sawe, Hendry Robert; Mfinanga, Juma A; Nshom, Ernest; Helm, Ethan; Moore, Charity G; Runyon, Michael S; Reynolds, Stacy L

    2017-07-10

    Pediatric sickle cell disease, highly prevalent in sub-Saharan Africa, carries great morbidity and mortality risk. Limited resources and monitoring make management of acute vaso-occlusive crises challenging. This study aims to evaluate the efficacy and safety of subdissociative intranasal ketamine as a cheap, readily available and easily administered adjunct to standard pain therapy. We hypothesise that subdissociative, intranasal ketamine may significantly augment current approaches to pain management in resource-limited settings in a safe and cost-effective manner. This is a multicentred, randomised, double-blind, placebo-controlled trial enrolling children 4-16 years of age with sickle cell disease and painful vaso-occlusive pain crises. Study sites include two sub-Saharan teaching and referral hospitals with acute intake areas. All patients receive standard analgesic therapy during evaluation. Patients randomised to the treatment arm receive 1 mg/kg intranasal ketamine at onset of therapy, while placebo arm participants receive volume-matched intranasal normal saline. All participants and clinical staff are blinded to the treatment allocation. Data will be analysed on an intention-to-treat basis. Primary endpoints are changes in self-report pain scales (Faces Pain Scale-Revised) at 30, 60 and 120 minutes and rates of adverse events. Secondary endpoints include hospital length of stay, total analgesia use and quality of life assessment 2-3 weeks postintervention. The research methods for this study have been approved by the Cameroon Baptist Convention Health Board Institutional Review Board (IRB2015-07), the Tanzanian National Institute for Medical Research (NIMR/HQ/R.8a/Vol. IX/2299), Muhimbili National Hospital IRB (MNH/IRB/I/2015/14) and the Tanzanian Food and Drugs Authority (TFDA0015/CTR/0015/9). Data reports will be provided to the Data and Safety Monitoring Board (DSMB) periodically throughout the study as well as all reports of adverse events. All

  9. Subdissociative intranasal ketamine plus standard pain therapy versus standard pain therapy in the treatment of paediatric sickle cell disease vaso-occlusive crises in resource-limited settings: study protocol for a randomised controlled trial

    PubMed Central

    Sawe, Hendry Robert; Mfinanga, Juma A; Nshom, Ernest; Helm, Ethan; Moore, Charity G; Runyon, Michael S; Reynolds, Stacy L

    2017-01-01

    Introduction Pediatric sickle cell disease, highly prevalent in sub-Saharan Africa, carries great morbidity and mortality risk. Limited resources and monitoring make management of acute vaso-occlusive crises challenging. This study aims to evaluate the efficacy and safety of subdissociative intranasal ketamine as a cheap, readily available and easily administered adjunct to standard pain therapy. We hypothesise that subdissociative, intranasal ketamine may significantly augment current approaches to pain management in resource-limited settings in a safe and cost-effective manner. Methods and analysis This is a multicentred, randomised, double-blind, placebo-controlled trial enrolling children 4–16 years of age with sickle cell disease and painful vaso-occlusive pain crises. Study sites include two sub-Saharan teaching and referral hospitals with acute intake areas. All patients receive standard analgesic therapy during evaluation. Patients randomised to the treatment arm receive 1 mg/kg intranasal ketamine at onset of therapy, while placebo arm participants receive volume-matched intranasal normal saline. All participants and clinical staff are blinded to the treatment allocation. Data will be analysed on an intention-to-treat basis. Primary endpoints are changes in self-report pain scales (Faces Pain Scale-Revised) at 30, 60 and 120 minutes and rates of adverse events. Secondary endpoints include hospital length of stay, total analgesia use and quality of life assessment 2–3 weeks postintervention. Ethics and dissemination The research methods for this study have been approved by the Cameroon Baptist Convention Health Board Institutional Review Board (IRB2015-07), the Tanzanian National Institute for Medical Research (NIMR/HQ/R.8a/Vol. IX/2299), Muhimbili National Hospital IRB (MNH/IRB/I/2015/14) and the Tanzanian Food and Drugs Authority (TFDA0015/CTR/0015/9). Data reports will be provided to the Data and Safety Monitoring Board (DSMB) periodically throughout

  10. Acute basilar artery occlusion treated by thromboaspiration in a cocaine and ecstasy abuser.

    PubMed

    Vallée, J-N; Crozier, S; Guillevin, R; Obadia, M; Lo, D; Barragan-Campos, H M; Samson, Y; Chiras, J

    2003-09-23

    Thromboaspiration was performed in a young adult in a coma because of acute basilar artery occlusion associated with cocaine and ecstasy abuse 30 hours after symptom onset. There was complete recanalization of the basilar artery and favorable recovery. Because cocaine and ecstasy abuse has been reported to be a risk factor for ischemic stroke and fatal brain hemorrhage, thromboaspiration may be an alternative therapy to thrombolysis.

  11. Biomechanics of occlusion--implications for oral rehabilitation.

    PubMed

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. © 2015 John Wiley & Sons Ltd.

  12. Dental occlusion and temporomandibular disorders.

    PubMed

    Stone, J Caitlin; Hannah, Andrew; Nagar, Nathan

    2017-10-27

    Data sourcesMedline, Scopus and Google Scholar.Study selectionTwo reviewers selected studies independently. English language clinical studies assessing the association between temporomandibular disorders (TMD) and features of dental occlusion were considered.Data extraction and synthesisStudy quality was assessed based on the Newcastle-Ottawa Scale (NOS) and a narrative synthesis was presented.ResultsIn all 25 studies (17 case-control, eight comparative) were included. Overall there was a high variability between occlusal features and TMD diagnosis. Findings were consistent with a lack of clinically relevant association between TMD and dental occlusion. Only two studies were associated with TMD in the majority (≥50%) of single variable analyses in patient populations. Only mediotrusive interferences are associated with TMD in the majority of multiple variable analyses.ConclusionsThe findings support the absence of a disease-specific association, there is no ground to hypothesise a major role for dental occlusion in the pathophysiology of TMDs. Dental clinicians are thus encouraged to move forward and abandon the old-fashioned gnathological paradig.

  13. [Effective dimethyl sulfoxide (DMSO) occlusive dressing technique for amyloidosis of the urinary bladder].

    PubMed

    Hasegawa, Yoshihiro; Kanda, Hideki; Miki, Manabu; Masui, Satoru; Yoshio, Yuko; Yamada, Yasushi; Soga, Norihito; Arima, Kiminobu; Sugimura, Yoshiki

    2013-10-01

    A 48-year-old married woman complaining of macroscopic hematuria and cystitis symptom was admitted to our institute. Flexible cystoscopy revealed many yellowish, nodular masses at the paries posterior of the urinary bladder, and cold-punch biopsy proved it to be amyloidosis. Serum amyloid protein A (SAA) was high, and suggested systemic amyloidosis. Renal biopsy and colon fiberscopy did not reveal any abnormalities. We therefore diagnosed a primary localized amyloidosis of the urinary bladder. Transurethral resection and dimethyl sulfoxide (DMSO) infusion therapy are used to treat amyloidosis of the urinary bladder. However there is no definite cure for amyloidosis of the urinary bladder. Therefore we selected DMSO occlusive dressing technique therapy. After 5 years of therapy, there was no evidence of a recurrence of amyloidosis.

  14. Randomized evaluation of spectacles plus alternate-day occlusion to treat amblyopia.

    PubMed

    Agervi, Pia; Kugelberg, Ulla; Kugelberg, Maria; Simonsson, Gunnela; Fornander, Monica; Zetterström, Charlotta

    2010-02-01

    To compare spectacles plus patching >or=8 hours daily 6 days a week with spectacles plus patching >or=8 hours on alternate days to treat amblyopia in children 4 to 5 years of age. Prospective, randomized clinical trial. Forty children (median age, 4.3 years) with untreated amblyopia and a median best-corrected visual acuity (BCVA) in the amblyopic eye of 0.9 (range, 0.3-1.5) logarithm of the minimum angle of resolution. Refractive correction was provided, and the children were randomized to patching >or=8 hours daily 6 days a week or patching >or=8 hours on alternate days. The BCVA, binocular function, and refractive errors were measured repeatedly during the study. Median change in BCVA of the amblyopic eye after 1 year. The median change in BCVA of the amblyopic eye did not differ significantly between the 2 groups (0.6 log units for daily occlusion; 0.8 log unit for alternate-day occlusion). The final median BCVA in the amblyopic eyes was 0.1 logarithm of the minimum angle of resolution in both groups. Binocular function improved in both groups with no significant differences between the groups at 1 year. The median spherical equivalent refractive error did not change significantly during the study period in the amblyopic eyes in either group; however, a significant increase was found in the fellow eyes in both groups (daily occlusion, P<0.05; alternate-day occlusion, P<0.001). The magnitude of change in the BCVA 1 year after spectacles plus prescribed alternate-day patching was not significantly different than that after spectacles plus prescribed daily patching to treat amblyopia in children 4 to 5 years old. The effect of patching was not separate from that of optical correction with a period of refractive adaptation. Thus, the improvement in visual acuity is a combined effect of spectacle wear and occlusion therapy. Copyright (c) 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  15. Conventional occlusion versus pharmacologic penalization for amblyopia.

    PubMed

    Li, Tianjing; Shotton, Kate

    2009-10-07

    Amblyopia is defined as defective visual acuity in one or both eyes without demonstrable abnormality of the visual pathway, and is not immediately resolved by wearing glasses. To assess the effectiveness and safety of conventional occlusion versus atropine penalization for amblyopia. We searched CENTRAL, MEDLINE, EMBASE, LILACS, the WHO International Clinical Trials Registry Platform, preference lists, science citation index and ongoing trials up to June 2009. We included randomized/quasi-randomized controlled trials comparing conventional occlusion to atropine penalization for amblyopia. Two authors independently screened abstracts and full text articles, abstracted data, and assessed the risk of bias. Three trials with a total of 525 amblyopic eyes were included. One trial was assessed as having a low risk of bias among these three trials, and one was assessed as having a high risk of bias.Evidence from three trials suggests atropine penalization is as effective as conventional occlusion. One trial found similar improvement in vision at six and 24 months. At six months, visual acuity in the amblyopic eye improved from baseline 3.16 lines in the occlusion and 2.84 lines in the atropine group (mean difference 0.034 logMAR; 95% confidence interval (CI) 0.005 to 0.064 logMAR). At 24 months, additional improvement was seen in both groups; but there continued to be no meaningful difference (mean difference 0.01 logMAR; 95% CI -0.02 to 0.04 logMAR). The second trial reported atropine to be more effective than occlusion. At six months, visual acuity improved 1.8 lines in the patching group and 3.4 lines in the atropine penalization group, and was in favor of atropine (mean difference -0.16 logMAR; 95% CI -0.23 to -0.09 logMAR). Different occlusion modalities were used in these two trials. The third trial had inherent methodological flaws and limited inference could be drawn.No difference in ocular alignment, stereo acuity and sound eye visual acuity between occlusion and

  16. The soleus syndrome. A cause of medial tibial stress (shin splints).

    PubMed

    Michael, R H; Holder, L E

    1985-01-01

    Radionuclide bone scans have demonstrated linear uptake along the posterior medial border of the tibia in patients with shin splints. This area was investigated by anatomical dissection (14 human cadavers), electromyographic (EMG) and muscle stimulation studies (10 patients), and open biopsy (1 patient). Histologically, the increased metabolic activity manifested on the radionuclide scan is due to a periostitis with new bone formation. The soleus muscle and its investing fascia are anatomically and biomechanically implicated in the production of these stress changes, particularly when the heel is in the pronated position. The soleus muscle and fascia form a tough "soleus bridge" over the deep compartment which is thought to be important in patients requiring surgical decompression.

  17. Occlusion for stimulus deprivation amblyopia.

    PubMed

    Antonio-Santos, Aileen; Vedula, Satyanarayana S; Hatt, Sarah R; Powell, Christine

    2014-02-06

    Stimulus deprivation amblyopia (SDA) develops due to an obstruction to the passage of light secondary to a condition such as cataract. The obstruction prevents formation of a clear image on the retina. SDA can be resistant to treatment, leading to poor visual prognosis. SDA probably constitutes less than 3% of all amblyopia cases, although precise estimates of prevalence are unknown. In developed countries, most patients present under the age of one year; in less developed parts of the world patients are likely to be older at the time of presentation. The mainstay of treatment is removal of the cataract and then occlusion of the better-seeing eye, but regimens vary, can be difficult to execute, and traditionally are believed to lead to disappointing results. Our objective was to evaluate the effectiveness of occlusion therapy for SDA in an attempt to establish realistic treatment outcomes. Where data were available, we also planned to examine evidence of any dose response effect and to assess the effect of the duration, severity, and causative factor on the size and direction of the treatment effect. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), the Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to October 2013), PubMed (January 1946 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com ), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 28 October 2013. We planned to include randomized and quasi-randomized controlled

  18. Occlusion for stimulus deprivation amblyopia

    PubMed Central

    Antonio-Santos, Aileen; Vedula, Satyanarayana S; Hatt, Sarah R; Powell, Christine

    2014-01-01

    Background Stimulus deprivation amblyopia (SDA) develops due to an obstruction to the passage of light secondary to a condition such as cataract. The obstruction prevents formation of a clear image on the retina. SDA can be resistant to treatment, leading to poor visual prognosis. SDA probably constitutes less than 3% of all amblyopia cases, although precise estimates of prevalence are unknown. In developed countries, most patients present under the age of one year; in less developed parts of the world patients are likely to be older at the time of presentation. The mainstay of treatment is removal of the cataract and then occlusion of the better-seeing eye, but regimens vary, can be difficult to execute, and traditionally are believed to lead to disappointing results. Objectives Our objective was to evaluate the effectiveness of occlusion therapy for SDA in an attempt to establish realistic treatment outcomes. Where data were available, we also planned to examine evidence of any dose response effect and to assess the effect of the duration, severity, and causative factor on the size and direction of the treatment effect. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), the Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to October 2013), PubMed (January 1946 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 28 October 2013. Selection criteria We planned

  19. Necrotizing Fasciitis of the Periorbital Region Complicated by Combined Central Retinal Artery Occlusion, Central Retinal Vein Occlusion, and Posterior Ciliary Occlusion.

    PubMed

    Sultan, Harris; Malik, Amina; Li, Helen K; Chévez-Barrios, Patricia; Lee, Andrew G

    A 50 year-old man on immunosuppressive agents presented with left eye vision loss, periorbital swelling, pain, and ophthalmoplegia. The patient was clinically found to have a central retinal artery and vein occlusion. A CT scan was performed which demonstrated intraorbital fat stranding, however the patient lacked sinus disease. The etiology of the orbital infection was held in question. The area was debrided in the operating room, and the specimen demonstrated group A streptococcal species consistent with necrotizing fasciitis. Periorbital necrotizing fasciitis should be suspected in patients with rapidly progressive orbital symptoms without sinus disease as lack of surgical intervention can result in poor outcomes. The unusual aspect to this case is the mechanism of vision loss, as the authors hypothesize that there was vascular infiltration of the infection resulting in the central retinal artery occlusion and central retinal vein occlusion which have not been previously reported secondary to necrotizing fasciitis of the orbit.

  20. Compartment syndrome and shin splints of the lower leg.

    PubMed

    Gerow, G; Matthews, B; Jahn, W; Gerow, R

    1993-05-01

    The objective of this article is to review and categorize the current knowledge on compartment syndromes (CS) and shin splints (SS), with specific importance relegated to the diagnosis, differential diagnosis and management of these conditions. The bibliographic data sources reviewed are limited to the English language and human content and are from medical and scientific journals, as well as chiropractic and medical texts. A mini-Medline version of Index Medicus was utilized. Terms for indexing included compartment syndromes, shin splints and stress fractures. The bibliographies of the journals selected were then evaluated and, where appropriate, the specific journal or text references regarding diagnosis and management were then reviewed. This information was then included in this article, where useful, to further clarify or reference statements made. Differential diagnosis of the acute CS from chronic CS and SS requires clinical methods and imaging procedures. The pathogenesis of the acute CS of the lower leg is associated with external pressure or internal hemorrhage. If the tissue pressure were to rise above 30-40 mm Hg for 4-12 h, irreversible muscular damage would result. Emergency surgical intervention is the only appropriate form of treatment in acute CS. In chronic CS, where elevated pressures exist on a transient basis, influenced by activity, conservative management procedures are felt to be effective. However, if these methods are not helpful, surgical intervention may be necessary. The etiology of pain associated with SS is not associated with compartmental pressure elevations, but rather, results from periostitis occurring along the tibia caused by muscular and tendinous strain associated with inflammation. Conservative management is most appropriate for this disorder, with surgical intervention being an uncommon treatment approach. Although clinical findings are useful in the diagnosis of these disorders, fluid pressure findings may be necessary to

  1. Neuromuscular dentistry: Occlusal diseases and posture

    PubMed Central

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K.

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture. PMID:25737904

  2. Epidemiology and clinical features of inflammatory retinal vascular occlusions: pooled data from two tertiary-referral institutions.

    PubMed

    Agarwal, Aniruddha; Karkhur, Samendra; Aggarwal, Kanika; Invernizzi, Alessandro; Singh, Ramandeep; Dogra, Mangat R; Gupta, Vishali; Gupta, Amod; Do, Diana V; Nguyen, Quan D

    2018-01-01

    In a subset of patients with retinal vasculitis, there is occlusion of blood flow through the retinal vessels. These eyes are at high risk of sight-threatening complications. To characterize epidemiology, clinical course, treatment and outcomes of occlusive retinal vasculitis (ORV). Retrospective study PARTICIPANTS: Seventy-seven uveitis patients with ORV at two large tertiary-care institutions (the USA and India). Out of 2438 patients screened, 346 patients were diagnosed with retinal vasculitis of which 77 patients (96 eyes) were diagnosed with ORV. Patients with ORV (capillary, arteriolar and/or venular) were further analysed. Diagnostic criteria for occlusive vasculitis included (i) absence of blood flow in vessels (arterioles, venules and/or capillaries), (ii) capillary non-perfusion areas and/or arteriolar-venous anastomosis and (iii) intraretinal haemorrhages, cotton-wool spots or vitreous haemorrhage. Best-corrected visual acuity, treatment and complications. The mean age was 32.09 ± 13.51 years. Most common aetiologies were tuberculosis and Adamantiades-Behçet's disease in India and systemic lupus erythematosus in the USA. Best-corrected visual acuity improved from 0.38 ± 0.30 logMAR (20/48 Snellen equivalent) (baseline) to 0.25 ± 0.30 (20/35 Snellen equivalent) at final visit (P < 0.0001). Vitreous haemorrhage was seen in 31.08% eyes. Pars plana vitrectomy was performed in 12.16% eyes. Therapy with systemic steroids was required in 78.48% patients. In addition, 46.75% patients required immunomodulators and/or biologics. Occlusive retinal vasculitis is caused by heterogeneous group of uveitides depending upon the geographic location. It is imperative to identify eyes with ORV as they are predisposed to complications requiring aggressive therapy. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  3. Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants.

    PubMed

    Wentaschek, Stefan; Scheller, Herbert; Schmidtmann, Irene; Hartmann, Sinsa; Weyhrauch, Michael; Weibrich, Gernot; Lehmann, Karl Martin

    2015-10-01

    To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. This retrospective study aimed to assess the suitability of three stability parameters - namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values - as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediately loaded using temporary fixed dentures. The IT results, PT values, and ISQ results were recorded. Receiver operating characteristic analysis was performed to assess the quality of each parameter as a diagnostic test. After a 3-month observation period, 11 implants in four patients were not osseointegrated. The IT and ISQ (IT 25.0 ± 12.5 Ncm and 8.4 ± 2.3 Ncm; PT -1.5 ± 3.0 and +2.7 ± 3.0; and ISQ 62.6 ± 6.7 and 54.7 ± 6.2) differed significantly between the osseointegrated and failed implants (p < .005). The IT showed the greatest specificity at a sensitivity of 1 and the greatest area under the curve (AUC; 0.929), followed by the PT value (AUC = 0.836) and ISQ (AUC = 0.811). Among the intraoperative parameters analyzed, IT showed the highest specificity at a high sensitivity of 1. Therefore, the IT can be considered the most valid prognostic factor for osseointegration of immediately loaded splinted dental implants. © 2014 Wiley Periodicals, Inc.

  4. Long-term application of computer-based pleoptics in home therapy: selected results of a prospective multicenter study.

    PubMed

    Kämpf, Uwe; Shamshinova, Angelika; Kaschtschenko, Tamara; Mascolus, Wilfried; Pillunat, Lutz; Haase, Wolfgang

    2008-01-01

    The paper presents selected results of a prospective multicenter study. The reported study was aimed at the evaluation of a software-based stimulation method of computer training applied in addition to occlusion as a complementary treatment for therapy-resistant cases of amblyopia. The stimulus was a drifting sinusoidal grating of a spatial frequency of 0.3 cyc/deg and a temporal frequency of 1 cyc/sec, reciprocally coordinated with each other to a drift of 0.33 deg/sec. This pattern was implemented as a background stimulus into simple computer games to bind attention by sensory-motor coordination tasks. According to an earlier proposed hypothesis, the stimulation aims at the provocation of stimulus-induced phase-coupling in order to contribute to the refreshment of synchronization and coordination processes in the visual transmission channels. To assess the outcome of the therapy, we studied the development of the visual acuity during a period of 6 months. Our cooperating partners of this prospective multicenter study were strabologic departments in ophthalmic clinics and private practices as well. For the issue of therapy control, a partial sample of 55 patients from an overall sample of 198 patients was selected, according to the criterion of strong therapy resistance. The visual acuity was increased about two logarithmic steps by an occlusion combined with computer training in addition to the earlier obtained gain of the same amount by occlusion alone. Recalculated relatively to the duration of the therapy periods, the computer training combined with occlusion was found to be about twice as effective as the preceding occlusion alone. The results of combined computer training and occlusion show an additional increase of the same amount as the preceding occlusion alone, which yielded at its end no further advantage to the development of visual acuity in the selected sample of our 55 therapy-resistant patients. In a concluding theoretical note, a preliminary

  5. Effects of Neoprene Wrist/Hand Splints on Handwriting for Students with Joint Hypermobility Syndrome: A Single System Design Study

    ERIC Educational Resources Information Center

    Frohlich, Lauren; Wesley, Alison; Wallen, Margaret; Bundy, Anita

    2012-01-01

    Purpose: Pain associated with hypermobility of wrist and hand joints can contribute to decreased handwriting output. This study examined the effectiveness of a neoprene wrist/hand splint in reducing pain and increasing handwriting speed and endurance for students with joint hypermobility syndrome. Methods: Multiple baseline, single system design…

  6. The comparative biomechanics of the reinforced interdental crossover and the Stout loop composite splints for mandibular fracture repair in dogs.

    PubMed

    Kitshoff, A M; de Rooster, H; Ferreira, S M; Burger, D; Steenkamp, G

    2013-01-01

    To describe a new technique, the reinforced interdental crossover composite splint (RIC), for transverse mandibular fracture repair in dogs. This technique was compared biomechanically with the established reinforced interdental Stout loop composite splint (RIS) technique. Six pairs of mandibles from young adult small breed dogs were used for the study. Osteotomies were created in a standardized fashion and fixed with either RIC or RIS. All composite splint constructs were tested biomechanically with a cantilever bending force, using a single column testing machine at a rate of 2 mm/min. The time of application, amount of composite used, ultimate force, stiffness, total displacement, and total energy absorbed during displacement of the rostral mandibular segment were calculated and compared between the two groups. No significant difference was found when comparing the time of application of the RIC and the RIS techniques. All implants failed by either composite resin fracture over the region of the osteotomy or by fracture between the first and second molar followed by detachment of the resin from the lingual enamel surface of the first molar. Differences between the RIC and RIS in force (80.5 N ± 40.3 and 51.8 N ± 27.4. respectively) and stiffness (16.2 N/mm ± 4.4 and 10.1 N/mm ± 4.1 respectively) were significant (p = 0.03). However differences between the two techniques in displacement and total energy absorbed were not significant. In experimentally fractured mandibles of young adult dogs there is evidence that RIC is biomechanically similar to RIS.

  7. The role of "rescue saccades" in tracking objects through occlusions.

    PubMed

    Zelinsky, Gregory J; Todor, Andrei

    2010-12-29

    We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking.

  8. Vascular occlusion with a balloon-expandable stent occluder.

    PubMed

    Moss, J G; Laborde, J C; Clem, M C; Rivera, F J; Encarnacion, C E; Meyer, K B; Palmaz, J C

    1994-05-01

    To evaluate the effectiveness of a new vascular occlusion device. The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. This new occlusive device offers immediate vascular occlusion with excellent stability.

  9. Good outcome rate of 35% in IV-tPA-treated patients with computed tomography angiography confirmed severe anterior circulation occlusive stroke.

    PubMed

    González, R Gilberto; Furie, Karen L; Goldmacher, Gregory V; Smith, Wade S; Kamalian, Shervin; Payabvash, Seyedmehdi; Harris, Gordon J; Halpern, Elkan F; Koroshetz, Walter J; Camargo, Erica C S; Dillon, William P; Lev, Michael H

    2013-11-01

    To determine the effect of intravenous tissue plasminogen activator (IV-tPA) on outcomes in patients with severe major anterior circulation ischemic stroke. Prospectively, 649 patients with acute stroke had admission National Institutes of Health stroke scale (NIHSS) scores, noncontrast computed tomography (CT), CT angiography (CTA), and 6-month outcome assessed using modified Rankin scale. IV-tPA treatment decisions were made before CTA, at the time of noncontrast CT scanning, as per routine clinical protocol. Severe symptoms were defined as NIHSS>10. Poor outcome was defined as modified Rankin scale >2. Major occlusions were identified on CTA. Univariate and multivariate stepwise-forward logistic regression analyses of the full cohort were performed. Of 649 patients, 188 (29%) patients presented with NIHSS>10, and 64 out of 188 (34%) patients received IV-tPA. Admission NIHSS, large artery occlusion, and IV-tPA all independently predicted good outcomes; however, a significant interaction existed between IV-tPA and occlusion (P<0.001). Of the patients who presented with NIHSS>10 with anterior circulation occlusion, twice the percentage had good outcomes if they received IV-tPA (17 out of 49 patients, 35%) than if they did not (13 out of 77 patients, 17%; P=0.031). The number needed to treat was 7 (95% confidence interval, 3-60). IV-tPA treatment resulted in significantly better outcomes in patients with severely symptomatic stroke with major anterior circulation occlusions. The 35% good outcome rate was similar to rates found in endovascular therapy trials. Vascular imaging may help in patient selection and stratification for trials of IV-thrombolytic and endovascular therapies.

  10. A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venbrux, Anthony C., E-mail: avenbrux@mfa.gwu.edu; Rudakov, Leon, E-mail: leonrudakov@artventivemedical.com; Plass, Andre, E-mail: andre.plass@usz.ch

    2013-05-24

    PurposeThe purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles.MethodsThe ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males,more » ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects.ResultsThe acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients.ConclusionsAlthough we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.« less

  11. [Pulmonary veno-occlusive disease/pulmonary capillary hemangiomatosis: A case report and literature review].

    PubMed

    Xiong, Xianliang; Zhu, Tengteng; Li, Jiang

    2018-05-28

    Pulmonary veno-occlusive disease (PVOD)/pulmonary capillary hemangiomatosis (PCH) is a rare form of pulmonary vascular disease that causes pulmonary arterial hypertension. The diagnosis of PVOD/PCH can be established by the combination of clinical features, physical examination, radiological findings, lung function, bronchoscopy and other resources. There is no established medical therapy for PVOD/PCH, and the only curative therapy for PVOD/PCH is lung transplantation. A girl with PVOD/PCH was diagnosed in the Second Xiangya Hospital. Combining the characteristics for this case with the relevant literature, we summarized the epidemiology, etiology, diagnosis and treatment for the disease to raise doctors' awareness for this rare disease.

  12. Effectiveness of PELOID therapy in carpal tunnel syndrome: A randomized controlled single blind study

    NASA Astrophysics Data System (ADS)

    Metin Ökmen, Burcu; Kasapoğlu Aksoy, Meliha; Güneş, Aygül; Eröksüz, Riza; Altan, Lale

    2017-08-01

    Carpal tunnel syndrome(CTS) is the most common neuromuscular cause of upper extremity disability. We aimed to investigate the effectiveness of peloid therapy in patients with CTS. This randomized, controlled, single-blind study enrolled 70 patients between the ages of 30 to 65 who had a diagnosis of either mild, mild-to-moderate, or moderate CTS. The patients were randomized into two groups using random number table. In the first group, (Group 1)( n = 35), patients were given splint (every night for 6 weeks) + peloid treatment(five consecutive days a week for 2 weeks) and in the second group, (Group 2)( n = 28), patients received splint treatment(every night for 6 weeks) alone. The patients were assessed by using visual analog scale(VAS) for pain, electroneuromyography(ENMG), the Boston Carpal Tunnel Syndrome Questionnaire(BCTSQ), hand grip strength(HGS), finger grip strength(FGS), and Short Form-12(SF-12). The data were obtained before treatment(W0), immediately after treatment(W2), and one month after treatment(W6). Both in Group 1 and 2, there was a statistically significant improvement in all the evaluation parameters at W2 and W6 when compared to W0( p < 0.05). Comparison of the groups with each other revealed significantly better results for VAS, BCTSQ, mSNCV, SF-12 in Group 1 than in Group 2 at W2( p < 0.05). There was also a statistically significant difference in favor of Group 1 for VAS, BCTSQ, FGS and MCS at W6 when compared to W0 ( p < 0.05). The results of our study demonstrated that in patients with CTS; peloid + splint treatment was more effective than splint treatment alone in pain, functionality and life quality both at after treatment(W2) and one month after treatment (W6). We may suggest peloid as a supplementary therapeutic agent in CTS.

  13. [Effectivity of an occlusion-supporting PC-based visual training programme by horizontal drifting sinus gratings in children with amblyopia].

    PubMed

    Bau, V; Rose, K; Pollack, K; Spoerl, E; Pillunat, L E

    2012-10-01

    The studies of Kämpf et al. suggested an efficiency of a computer-based stimulation therapy by drifting sinus gratings in patients with anisometropic and/or strabismic amblyopia but provided no clear evidence. This is the first trial with amblyopic patients without previous treatment at the beginning of amblyopia therapy. A prospective, randomised, single-blinded, placebo-controlled study of n = 15 patients with anisometropic and/or strabismic amblyopia without previous treatment was performed. Age of the patients was between 4 and 10 years, mean 6.3 years (± 2.0), all after full correction of refraction errors and refractive adaptation. Stimulation therapy was performed 5 times a week over 4 weeks, respectively 2 × 20 min, a drifting sinus grating of constant spatial and temporal frequency was combined with computer games (n = 8). Control group had only computer games with a neutral background (n = 7). In both groups patching was only done in stimulation times. Stimulation and control group did not differ due to age, gender, and cause of amblyopie, baseline visual acuity, and time of wearing glasses. There was no significant difference in the development of visual acuity over the stimulation period between stimulation and control groups. Stimulation therapy with drifting sinus gratings did not improve the development of visual acuity in the first phase of amblyopia treatment combined with minimal occlusion therapy. Accordingly, the stimulation therapy is not adequate to replace sufficient occlusion therapy. Whether this therapy could support patching therapy and improve acuity development in later therapy phases cannot be assumed from this trial. Georg Thieme Verlag KG Stuttgart · New York.

  14. Strategy for the Management of Macular Edema in Retinal Vein Occlusion: The European VitreoRetinal Society Macular Edema Study

    PubMed Central

    Adelman, Ron A.; Parnes, Aaron J.; Bopp, Silvia; Saad Othman, Ihab; Ducournau, Didier

    2015-01-01

    Objective. To compare the efficacy of different therapies in the treatment of macular edema associated with retinal vein occlusion (RVO). Design. This is a nonrandomized, multicenter collaborative study. Participants. 86 retina specialists from 29 countries provided clinical information, including choice of treatment and outcome, on 2,603 patients with macular edema including 738 cases of RVO. Methods. Reported data included the type and number of treatments performed, visual acuities, and other clinical and diagnostic findings. Main Outcome Measures. The mean increase in visual acuity and mean number of treatments performed. Results. 358 cases of central retinal vein occlusion (CRVO) and 380 cases of branch retinal vein occlusion (BRVO) were included in this investigation. Taking all RVO cases together, pars plana vitrectomy with internal limiting membrane (ILM) peeling alone resulted in an improvement in vision greater than other therapies. Those treated with intravitreal antivascular endothelial growth factor (anti-VEGF) injection alone showed the second greatest improvement in vision. Dexamethasone intravitreal implant alone and intravitreal triamcinolone alone both resulted in modest visual gains. Conclusions. In the treatment of macular edema in RVO, vitrectomy with ILM peeling may achieve visual improvement and may be a good option for certain cases. Anti-VEGF injection is the most effective of the nonsurgical treatments. PMID:25705695

  15. Occlusion issues in early Renaissance art

    PubMed Central

    Gillam, Barbara

    2011-01-01

    Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings. PMID:23145262

  16. [Manipulative reduction and external fixation with cardboard splint for the treatment of calcaneal fractures: a 60-case report].

    PubMed

    Hao, Bo-Chuan; Xie, Ke-Bo

    2014-07-01

    To investigate the therapeutic effects of manipulative reduction for calcaneal fractures. From January 2009 to June 2012, 53 cases (60 affected feet) of Sanders type I-IV calcaneal fractures were treated by manipulative reduction and external fixation with cardboard splint,including 45 males and 8 females with an average age of (33.5 +/- 1.54) years old ranging from 18 to 65. The course of disease ranged 0.5 h to 7 d. Before treatment the feet were swelling, ache and activity limitation in evidence, some feet were wide flat deformity, the cortical bone was broken in the imaging examination. All selected cases were evaluated using Creighton-Nebraska health foundation assessment scale for fractures of calcaneus. All cases were followed up at 12 months after treatment, 13 feet got excellent curative effect, 34 good, 11 moderate and 2 poor. Manipulative reduction for Sanders type I-IV calcaneal fractures could get excellent curative effect. Manipulative reduction for calcaneal fractures could avoid surgical trauma while assure high curative effects. Manipulative reduction is not only economical and easy therapy, but also can restore maximum function of the calcaneus with few complications and facilitate early rehabilitation of ankle and joint function.

  17. A Three-Dimensional Finite Element Analysis of the Stress Distribution Generated by Splinted and Nonsplinted Prostheses in the Rehabilitation of Various Bony Ridges with Regular or Short Morse Taper Implants.

    PubMed

    Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina; Ribeiro, Ricardo Faria; de Mattos, Maria G

    The aim of this study was to compare the biomechanical performance of splinted or nonsplinted prostheses over short- or regular-length Morse taper implants (5 mm and 11 mm, respectively) in the posterior area of the mandible using finite element analysis. Three-dimensional geometric models of regular implants (Ø 4 × 11 mm) and short implants (Ø 4 × 5 mm) were placed into a simulated model of the left posterior mandible that included the first premolar tooth; all teeth posterior to this tooth had been removed. The four experimental groups were as follows: regular group SP (three regular implants were rehabilitated with splinted prostheses), regular group NSP (three regular implants were rehabilitated with nonsplinted prostheses), short group SP (three short implants were rehabilitated with splinted prostheses), and short group NSP (three short implants were rehabilitated with nonsplinted prostheses). Oblique forces were simulated in molars (365 N) and premolars (200 N). Qualitative and quantitative analyses of the minimum principal stress in bone were performed using ANSYS Workbench software, version 10.0. The use of splinting in the short group reduced the stress to the bone surrounding the implants and tooth. The use of NSP or SP in the regular group resulted in similar stresses. The best indication when there are short implants is to use SP. Use of NSP is feasible only when regular implants are present.

  18. A Method of Three-Dimensional Recording of Mandibular Movement Based on Two-Dimensional Image Feature Extraction

    PubMed Central

    Li, Zhongke; Yang, Huifang; Lü, Peijun; Wang, Yong; Sun, Yuchun

    2015-01-01

    Background and Objective To develop a real-time recording system based on computer binocular vision and two-dimensional image feature extraction to accurately record mandibular movement in three dimensions. Methods A computer-based binocular vision device with two digital cameras was used in conjunction with a fixed head retention bracket to track occlusal movement. Software was developed for extracting target spatial coordinates in real time based on two-dimensional image feature recognition. A plaster model of a subject’s upper and lower dentition were made using conventional methods. A mandibular occlusal splint was made on the plaster model, and then the occlusal surface was removed. Temporal denture base resin was used to make a 3-cm handle extending outside the mouth connecting the anterior labial surface of the occlusal splint with a detection target with intersecting lines designed for spatial coordinate extraction. The subject's head was firmly fixed in place, and the occlusal splint was fully seated on the mandibular dentition. The subject was then asked to make various mouth movements while the mandibular movement target locus point set was recorded. Comparisons between the coordinate values and the actual values of the 30 intersections on the detection target were then analyzed using paired t-tests. Results The three-dimensional trajectory curve shapes of the mandibular movements were consistent with the respective subject movements. Mean XYZ coordinate values and paired t-test results were as follows: X axis: -0.0037 ± 0.02953, P = 0.502; Y axis: 0.0037 ± 0.05242, P = 0.704; and Z axis: 0.0007 ± 0.06040, P = 0.952. The t-test result showed that the coordinate values of the 30 cross points were considered statistically no significant. (P<0.05) Conclusions Use of a real-time recording system of three-dimensional mandibular movement based on computer binocular vision and two-dimensional image feature recognition technology produced a recording

  19. Time to aortic occlusion: It's all about access.

    PubMed

    Romagnoli, Anna; Teeter, William; Pasley, Jason; Hu, Peter; Hoehn, Melanie; Stein, Deborah; Scalea, Thomas; Brenner, Megan

    2017-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less invasive method of proximal aortic occlusion compared with resuscitative thoracotomy with aortic cross-clamping (RTACC). This study compared time to aortic occlusion with REBOA and RTACC, both including and excluding time required for common femoral artery (CFA) cannulation. This was a retrospective, single-institution review of REBOA or RTACC performed between February 2013 and January 2016. Time of skin incision to aortic cross-clamp for RTACC, time required for CFA cannulation by percutaneous and open methods, and time from guide-wire insertion to balloon inflation at Zone 1 for REBOA, were obtained from videographic recordings. Eighteen RTACC and 21 REBOAs were performed. Median (Q1, Q3) time from skin incision to aortic cross-clamping was 317 seconds (227, 551 seconds). Median (Q1, Q3) time from start of arterial access to Zone 1 balloon occlusion was 474 seconds (431, 572 seconds) (vs. RTACC, p = 0.01). All REBOA procedures were performed with the same device. The median time to complete CFA cannulation was 247 seconds (range, 164-343 seconds), with no difference between percutaneous or open procedures (p = 0.07). The median (Q1, Q3) time to aortic occlusion in REBOA once arterial access had been established was 245 seconds (179, 295.5 seconds), which was significantly shorter than RTACC (p = 0.003). Once CFA access is achieved, time to aortic occlusion is faster with REBOA. Time to aortic occlusion is less than the time required to cannulate the CFA either by percutaneous or open approaches, emphasizing the importance of accurate and expedient CFA access. Resuscitative endovascular balloon occlusion of the aorta may represent a feasible alternative to thoracotomy for aortic occlusion. Time to aortic occlusion will likely decrease with the advent of newer REBOA technology. The rate-limiting portion of REBOA continues to be obtaining CFA access. Therapeutic, level V.

  20. Predictors of early stent occlusion among plastic biliary stents.

    PubMed

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  1. Influence of denture adhesives on occlusion and disocclusion times.

    PubMed

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  2. Adhesive taping vs. daily manual muscle stretching and splinting after botulinum toxin type A injection for wrist and fingers spastic overactivity in stroke patients: a randomized controlled trial.

    PubMed

    Santamato, Andrea; Micello, Maria Francesca; Panza, Francesco; Fortunato, Francesca; Picelli, Alessandro; Smania, Nicola; Logroscino, Giancarlo; Fiore, Pietro; Ranieri, Maurizio

    2015-01-01

    To compare the effectiveness of two procedures increasing the botulinum toxin type A effect for wrist and finger flexor spasticity after stroke. A single-blind randomized trial. Seventy patients with upper limb post-stroke spasticity. Adults with wrist and finger flexor muscles spasticity after stroke were submitted to botulinum toxin type A therapy. After the treatment, the subjects injected were randomly divided into two groups and submitted to adhesive taping (Group A) or daily muscle manual stretching, passive articular mobilization of wrist and fingers, and palmar splint (Group B) for 10 days. We measured spasticity with Modified Ashworth Scale, related disability with Disability Assessment Scale, and fingers position at rest. The measurements were done at baseline, after two weeks, and after one month from the treatment session. After two weeks, subjects in Group A reported a significantly greater decrease in spasticity scores (Modified Ashworth Scale fingers: mean (standard deviation) 1.3±0.6 vs. 2.1±0.6; Modified Ashworth Scale wrist: 1.7 ±0.6 vs. 2.3 ±0.8), and after one month in spasticity and disability scores (Modified Ashworth Scale fingers: mean (standard deviation) 1.9 ±0.7 vs. 2.5 ±0.6; Modified Ashworth Scale wrist: 2.0 ±0.7 vs. 2.6 ±0.6; Disability Assessment Scale: 1.6 ±0.7 vs. 2.1 ±0.7) compared with Group B subjects. Subjects in Group A reported also a significantly improved fingers position at rest compared with Group B subjects after two weeks (2.8 ±0.9 vs. 2.1 ±0.7) and one month (2.3 ±0.7 vs. 1.5 ±0.6). Adhesive taping of wrist and finger flexor muscles appeared to enhance the effect of botulinum toxin type A therapy more than daily manual muscle stretching combined with passive articular mobilization and palmar splint. © The Author(s) 2014.

  3. Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

    PubMed Central

    Choi, Sulki

    2017-01-01

    PURPOSE The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness. PMID:29279761

  4. EMBOLIC MIDDLE CEREBRAL ARTERY OCCLUSION MODEL USING THROMBIN AND FIBRINOGEN COMPOSED CLOTS IN RAT

    PubMed Central

    Ren, Ming; Lin, Zi-Jing; Qian, Hai; Gourav, Choudhury Roy; liu, Ran; Liu, Hanli; Yang, Shao-Hua

    2012-01-01

    Ischemic stroke accounts for over 80% in total human stroke which mostly affect middle cerebral artery (MCA) territory. Embolic stroke models induced by injection of homologous clots into the internal carotid artery and MCA closely mimic human stroke and have been commonly used in stroke research. Studies indicate that the size and composition of clots are critical for the reproducibility of the stroke model. In the present study, we modified the homologous clots formation by addition of thrombin and fibrinogen which produced even distribution of fibrin with tight cross linkage of red blood cells. We optimized the embolic MCA occlusion model in rats using different size of the mixed clots. A precise lodgment of the clots at the MCA bifurcation and highly reproducible ischemic lesion in the MCA territory were demonstrated in the embolic MCA occlusion model induced by injection of 10 pieces of 1-mm long mixed clots made in PE-60 catheter. We further tested the effect of recombinant tissue plasminogen activator (rtPA) in this embolic MCA occlusion model. rtPA induced thrombolysis, improved neurological outcome, and significantly reduced ischemic lesion volume when administered at 1 hour after embolism as compared with control. In summary, we have established a reproducible embolic MCA occlusion model using clots made of homologous blood, thrombin and fibrinogen. The mixed clots enable precise lodgment at the MCA bifurcation which is responsive to thrombolytic therapy of rtPA. PMID:22985597

  5. Embolic middle cerebral artery occlusion model using thrombin and fibrinogen composed clots in rat.

    PubMed

    Ren, Ming; Lin, Zi-Jing; Qian, Hai; Choudhury, Gourav Roy; Liu, Ran; Liu, Hanli; Yang, Shao-Hua

    2012-11-15

    Ischemic stroke accounts for over 80% in total human stroke which mostly affect middle cerebral artery (MCA) territory. Embolic stroke models induced by injection of homologous clots into the internal carotid artery and MCA closely mimic human stroke and have been commonly used in stroke research. Studies indicate that the size and composition of clots are critical for the reproducibility of the stroke model. In the present study, we modified the homologous clots formation by addition of thrombin and fibrinogen which produced even distribution of fibrin with tight cross linkage of red blood cells. We optimized the embolic MCA occlusion model in rats using different size of the mixed clots. A precise lodgment of the clots at the MCA bifurcation and highly reproducible ischemic lesion in the MCA territory were demonstrated in the embolic MCA occlusion model induced by injection of 10 pieces of 1-mm long mixed clots made in PE-60 catheter. We further tested the effect of recombinant tissue plasminogen activator (rtPA) in this embolic MCA occlusion model. rtPA induced thrombolysis, improved neurological outcome, and significantly reduced ischemic lesion volume when administered at 1h after embolism as compared with control. In summary, we have established a reproducible embolic MCA occlusion model using clots made of homologous blood, thrombin and fibrinogen. The mixed clots enable precise lodgment at the MCA bifurcation which is responsive to thrombolytic therapy of rtPA. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Lower body positive pressure application with an antigravity suit in acute carotid occlusion.

    PubMed

    Berthet, Karine; Lukaszewicz, Anne Claire; Bousser, Marie-Germaine; Payen, Didier

    2010-04-01

    The challenge in acute stroke is still to reperfuse as early as possible the ischemic territory. Since fibrinolytic therapies have a limited window with potential risk of bleeding, having a nonpharmacologic mean to recruit vessels in area surrounding necrosis might be useful. We propose here to use antigravity suit inflated at "venous" pressure levels to shift blood towards thoracic and brain territories. We report two cases of spectacular clinical recovery after acute carotid occlusion.

  7. First experiences with a new device for mechanical thrombectomy in acute basilar artery occlusion.

    PubMed

    Roth, C; Mielke, A; Siekmann, R; Ferbert, A

    2011-01-01

    The aim of this study was to evaluate our first results using a new device for mechanical thrombectomy in patients with acute basilar artery occlusion. Between May 2009 and September 2010 a new device for aspiration thrombectomy (The Penumbra System™; Penumbra Inc., Alameda, Calif., USA) was used in 12 patients with acute basilar artery occlusion. We performed a retrospective review of these patients' medical records. One patient received endovascular treatment without intravenous (IV) thrombolysis because of infarction on the initial CT scan. Eleven of 12 patients received IV thrombolysis with rtPA followed by endovascular thrombectomy according to a bridging concept. After thrombolysis, the basilar artery was patent in 1 patient (9%), partially recanalized in 3 (27%) and still occluded in 7 (64%). The endovascular device could not access in 2 patients (17%). Among the remaining 10 patients, the patency rate after thrombectomy was 100%. The overall patency rate after treatment was 9 of 12 (75%) at the time of discharge. National Institute of Health Stroke Scale improved from a median of 27 to a median of 18 after treatment. Four patients died (33%). The survivors had a mean modified Rankin Scale before discharge of 2.3 (range 0-4). A bridging therapy with the combination of IV thrombolysis with recombinant tissue plasminogen activator and continuous aspiration thrombectomy seems to be a promising therapy strategy for acute basilar artery occlusion. Furthermore, our results confirm the advantage of the additional use of this new thrombectomy device, working with thrombus aspiration, with a satisfactory patency rate and a good clinical outcome. Copyright © 2011 S. Karger AG, Basel.

  8. Mandibular Advancement Splint as Short-Term Alternative Treatment in Patients with Obstructive Sleep Apnea Already Effectively Treated with Continuous Positive Airway Pressure

    PubMed Central

    Almeida, Fernanda R.; Mulgrew, Alan; Ayas, Najib; Tsuda, Hiroko; Lowe, Alan A.; Fox, Nurit; Harrison, Sandra; Fleetham, John A.

    2013-01-01

    Study Objectives: CPAP is used as the first-line treatment for patients with severe OSA, but this machine is not always feasible to use on the long term. We performed a clinical trial to determine whether patients with OSA could use a mandibular advancement splint (MAS) as a short-term treatment alternative to CPAP. Methods: Twenty-two patients adherent with CPAP therapy were recruited to the study. Each patient used the MAS for approximately 4 months. The transition between CPAP to MAS was gradual, and patients were asked to start using MAS together with CPAP during the MAS titration until subjective improvement or maximum mandibular advancement was achieved. Sleepiness (ESS), quality of life (SAQLI), and polysomnography were recorded prior to and after MAS titration. Patients recorded CPAP or MAS usage for the following 3 months. Results: Seven women and 12 men with a mean age of 53.8 (± 12.1) years and mean body mass index of 28.1 (± 4.8) kg/m2 completed the clinical trial. Prior to MAS, CPAP adherence was 5.8 h/night. AHI decreased significantly with MAS use compared to baseline (30.7 ± 23.1 vs 13.2 ± 11; p < 0.01). Fourteen patients (74%) had > 50% decrease in their AHI, while 2 patients had an increase in their AHI. There were no significant differences in SAQLI between MAS and CPAP treatment, while ESS decreased significantly on MAS. MAS self-reported usage was correlated with treatment efficacy (r = 0.52; p < 0.05). Seventy-five percent of the patients reported being sufficiently satisfied with MAS to continue to use it as an alternative short-term therapy. Conclusions: MAS partially or completely reduced sleep disordered breathing in the majority of selected, successfully CPAP-treated severe OSA patients. Many patients can probably effectively use MAS as a short-term treatment alternative to CPAP. Clinical Trial Registration: ClinicalTrials.gov registration number NCT00358605. Commentary: A commentary on this article appears in this issue on page 325

  9. Recanalization and clinical outcome of occlusion sites at baseline CT angiography in the Interventional Management of Stroke III trial.

    PubMed

    Demchuk, Andrew M; Goyal, Mayank; Yeatts, Sharon D; Carrozzella, Janice; Foster, Lydia D; Qazi, Emmad; Hill, Michael D; Jovin, Tudor G; Ribo, Marc; Yan, Bernard; Zaidat, Osama O; Frei, Donald; von Kummer, Rüdiger; Cockroft, Kevin M; Khatri, Pooja; Liebeskind, David S; Tomsick, Thomas A; Palesch, Yuko Y; Broderick, Joseph P

    2014-10-01

    To use baseline computed tomographic (CT) angiography to analyze imaging and clinical end points in an Interventional Management of Stroke III cohort to identify patients who would benefit from endovascular stroke therapy. The primary clinical end point was 90-day dichotomized modified Rankin Scale (mRS) score. Secondary end points were 90-day mRS score distribution and 24-hour recanalization. Prespecified subgroup was baseline proximal occlusions (internal carotid, M1, or basilar arteries). Exploratory analyses were subsets with any occlusion and specific sites of occlusion (two-sided α = .01). Of 656 subjects, 306 (47%) underwent baseline CT angiography or magnetic resonance angiography. Of 306, 282 (92%) had arterial occlusions. At baseline CT angiography, proximal occlusions (n = 220) demonstrated no difference in primary outcome (41.3% [62 of 150] endovascular vs 38% [27 of 70] intravenous [IV] tissue-plasminogen activator [tPA]; relative risk, 1.07 [99% confidence interval: 0.67, 1.70]; P = .70); however, 24-hour recanalization rate was higher for endovascular treatment (n = 167; 84.3% [97 of 115] endovascular vs 56% [29 of 52] IV tPA; P < .001). Exploratory subgroup analysis for any occlusion at baseline CT angiography did not demonstrate significant differences between endovascular and IV tPA arms for primary outcome (44.7% [85 of 190] vs 38% [35 of 92], P = .29), although ordinal shift analysis of full mRS distribution demonstrated a trend toward more favorable outcome (P = .011). Carotid T- or L-type occlusion (terminal internal carotid artery [ICA] with M1 middle cerebral artery and/or A1 anterior cerebral artery involvement) or tandem (extracranial or intracranial) ICA and M1 occlusion subgroup also showed a trend favoring endovascular treatment over IV tPA alone for primary outcome (26% [12 of 46] vs 4% [one of 23], P = .047). Significant differences were identified between treatment arms for 24-hour recanalization in proximal occlusions; carotid T

  10. Results of a bone splint technique for the treatment of lower limb deformities in children with type I osteogenesis imperfecta

    PubMed Central

    Lin, Dasheng; Zhai, Wenliang; Lian, Kejian; Ding, Zhenqi

    2013-01-01

    Background: Children with osteogenesis imperfecta (OI) can suffer from frequent fractures and limb deformities, resulting in impaired ambulation. Osteopenia and thin cortices complicate orthopedic treatment in this group. This study evaluates the clinical results of a bone splint technique for the treatment of lower limb deformities in children with type I OI. The technique consists of internal plating combined with cortical strut allograft fixation. Materials and Methods: We prospectively followed nine children (five boys, four girls) with lower limb deformities due to type I OI, who had been treated with the bone splint technique (11 femurs, four tibias) between 2003 and 2006. The fracture healing time, deformity improvement, ambulation ability and complications were recorded to evaluate treatment effects. Results: At the time of surgery the average age in our study was 7.7 years (range 5-12 years). The average length of followup was 69 months (range 60-84 months). All patients had good fracture healing with an average healing time of 14 weeks (range 12-16 weeks) and none experienced further fractures, deformity, or nonunion. The fixation remained stable throughout the procedure in all cases, with no evidence of loosening or breakage of screws and the deformity and mobility significantly improved after surgery. Of the two children confined to bed before surgery, one was able to walk on crutches and the other needed a wheelchair. The other seven patients could walk without walking aids or support like crutches. Conclusions: These findings suggest that the bone splint technique provides good mechanical support and increases the bone mass. It is an effective treatment for children with OI and lower limb deformities. PMID:23960282

  11. An epiphyseal stress fracture of the foot and shin splints in an anomalous calf muscle in a runner.

    PubMed

    Percy, E C; Gamble, F O

    1980-07-01

    The following case is presented as one of unusual foot and leg lesions encountered in an adolescent long-distance runner. The associated problems of a first metatarsal Salter Harris type II epiphyseal stress fracture, and an accessory calf muscle with "shin splints" in the contralateral leg are discussed. Treatment of these conditions is outlined with eventual return to full function by the athlete.

  12. Outcomes of 3 hours part-time occlusion treatment combined with near activities among children with unilateral amblyopia.

    PubMed

    Alotaibi, Abdullah G; Fawazi, Samah M; Alenazy, Badriah R; Abu-Amero, Khaled K

    2012-04-01

    To evaluate the outcome of part-time occlusion therapy with or without near activities in monocular amblyopic patients. One hundred and thirty patients who prescribed daily occlusion therapy (part-time occlusion) were followed-up for a 12-week period. The study was carried out in the Pediatric Ophthalmology and Orthoptics Clinics of King Abdul-Aziz University Hospital, Riyadh, Saudi Arabia for the period from January to November 2010. Sixty-five patients were recommended to undertake the 3 hours of near visual activities (such as reading a book during patching) while the other 65 patients were not advised to do any near activity. Main outcome measures were best corrected visual acuity (VA) for both groups and line improvement. The total line of VA improved from baseline by an average of 6.7+/-2.37 line log MAR (logarithm of the minimum angle of resolution) units in the group of patching with near activities and by an average of 5.3+/- 2.04 line log MAR units in the group of patching without near activities. All type of amblyopia (strabismic, anisometropic, and mixed types of amblyopia) improved significantly after patching with near activities. Both moderate and severe amblyopia improved significantly in the group of near activities compared with the group without near activities. Performing near activities while patching in the treatment of anisometropic, stabismic, or combined amblyopia improves the VA outcome more than patching alone.

  13. [Manipulative reduction and small splint fixation combined with micromovement exercise for treatment of humeral shaft fractures].

    PubMed

    Tang, Hao-chen; Xiang, Ming; Chen, Hang; Hu, Xiao-chuan; Yang, Guo-yong

    2016-01-01

    To investigate the therapeutic efficacy of bone-setting manipulative reduction and small splint fixation combined with micro-movement theory exercise for treatment of humeral shaft fractures. From March 2011 to February 2014, 64 cases of humeral shaft fractures were treated by bone-setting manipulative reduction and small splint fixation including 28 males and 36 females with an average age of 38.1 years old ranging from 22 to 67 years old. According to the classification of AO/OTA, there were 10 cases of type A1, 12 cases of type A2,11 cases of type A3,10 cases of type B1,12 cases of type B2, 7 cases of type B3, 2 cases of type C1, 1 case of type C2, 1 case of type C3. After close reduction early functional exercise performed according to micro-movement theory. All patients had no other parts of the fractures, neurovascular injury, and serious medical problems. Patients were followed up for fracture healing, shoulder and elbow joint function recovery, and curative effect. All patients were followed up from 10 to 12 months with an average of 10.3 months. Of them, 2 cases had a small amount of callus growth at 3 months after close reduction, so instead of operation; 2 cases appeared radial nerve symptoms after close reduction ,so instead of operation. Other patients were osseous healing, the time was 8 to 12 weeks with an average of 10.2 weeks. After osseous healing, according to Constant-Murley score system ,the average score was (93.5 ± 3.2) points, the result was excellent in 29 cases, good in 29 cases, fair in 6 cases, excellent and good rate was 90.3%; according to the Mayo score system, the average score was (93.7 ± 4.2) points, the result was excellent in 35 cases, good in 23 cases, fair in 6 cases, excellent and good rate was 91.9%. Bone-setting manipulative reduction and small splint fixation combined with micromovement theory exercise for treatment of humeral shaft fractures has advantage of positive effect, easy and inexpensive method, the treatment has

  14. Volumetric ambient occlusion for real-time rendering and games.

    PubMed

    Szirmay-Kalos, L; Umenhoffer, T; Toth, B; Szecsi, L; Sbert, M

    2010-01-01

    This new algorithm, based on GPUs, can compute ambient occlusion to inexpensively approximate global-illumination effects in real-time systems and games. The first step in deriving this algorithm is to examine how ambient occlusion relates to the physically founded rendering equation. The correspondence stems from a fuzzy membership function that defines what constitutes nearby occlusions. The next step is to develop a method to calculate ambient occlusion in real time without precomputation. The algorithm is based on a novel interpretation of ambient occlusion that measures the relative volume of the visible part of the surface's tangent sphere. The new formula's integrand has low variation and thus can be estimated accurately with a few samples.

  15. Varying face occlusion detection and iterative recovery for face recognition

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Hu, Zhengping; Sun, Zhe; Zhao, Shuhuan; Sun, Mei

    2017-05-01

    In most sparse representation methods for face recognition (FR), occlusion problems were usually solved via removing the occlusion part of both query samples and training samples to perform the recognition process. This practice ignores the global feature of facial image and may lead to unsatisfactory results due to the limitation of local features. Considering the aforementioned drawback, we propose a method called varying occlusion detection and iterative recovery for FR. The main contributions of our method are as follows: (1) to detect an accurate occlusion area of facial images, an image processing and intersection-based clustering combination method is used for occlusion FR; (2) according to an accurate occlusion map, the new integrated facial images are recovered iteratively and put into a recognition process; and (3) the effectiveness on recognition accuracy of our method is verified by comparing it with three typical occlusion map detection methods. Experiments show that the proposed method has a highly accurate detection and recovery performance and that it outperforms several similar state-of-the-art methods against partial contiguous occlusion.

  16. Lower Body Positive Pressure Application with an Antigravity Suit in Acute Carotid Occlusion

    PubMed Central

    Berthet, Karine; Lukaszewicz, Anne Claire; Bousser, Marie-Germaine; Payen, Didier

    2010-01-01

    The challenge in acute stroke is still to reperfuse as early as possible the ischemic territory. Since fibrinolytic therapies have a limited window with potential risk of bleeding, having a nonpharmacologic mean to recruit vessels in area surrounding necrosis might be useful. We propose here to use antigravity suit inflated at “venous” pressure levels to shift blood towards thoracic and brain territories. We report two cases of spectacular clinical recovery after acute carotid occlusion. PMID:20798842

  17. Dental cervical lesions associated with occlusal erosion and attrition.

    PubMed

    Khan, F; Young, W G; Shahabi, S; Daley, T J

    1999-09-01

    Acid demineralization of teeth causes occlusal erosion and attrition, and shallow and wedge-shaped cervical lesions putatively involving abfraction. From 250 patients with tooth wear, 122 with cervical lesions were identified. From epoxy resin replicas of their dentitions, associations of occlusal attrition or erosion or no wear with cervical lesions were recorded at 24 tooth sites (total 2928 sites). Criteria used to discriminate occlusal attrition from erosion, and shallow from grooved, wedge-shaped or restored cervical lesions were delineated by scanning electron microscopy. A 96 per cent association was found between occlusal and cervical pathology. Shallow cervical lesions were more commonly found in association with occlusal erosion. Wedge-shaped lesions were found equally commonly in association with occlusal erosion, as with attrition. Grooved and restored cervical lesions were uncommon. Differences were appreciated in the associations within incisor, canine, premolar and molar tooth sites which related more to the site-specificity of dental erosion than to attrition from occlusal forces. Non-carious lesions on teeth then have multifactorial aetiology and pathogenesis in which erosion and salivary protection play central roles. Dentists should primarily consider erosion in the diagnosis, prevention and treatment of tooth wear.

  18. [Navigated retinal laser therapy].

    PubMed

    Kernt, M; Ulbig, M; Kampik, A; Neubauer, A S

    2013-08-01

    Navigated laser therapy introduces for the first time computerized assistance systems for retinal laser therapy. The Navilas system offers high precision and safety and provides additional benefits regarding standardization of planning, execution, documentation and quality assurance. The current focus of clinical application for navigated laser therapy besides laser treatment after retinal vein occlusion and panretinal laser photocoagulation in proliferative diabetic retinopathy (PDR) is diabetic macular edema. Recent data indicate that combined initial anti-vascular endothelial growth factor (anti-VEGF) and navigated macular laser therapy allows achievement and maintenance of treatment success with a minimum number of interventions. Despite very promising results the current assessment of navigated laser therapy is still limited by the evidence available worldwide.

  19. Sigmoid sinus occlusion infiltrated by inflammatory myofibroblastic tumor from mastoid.

    PubMed

    Wang, Jingye; Sun, Zhongwu; Zhuo, Shengxia; Wang, Kai

    2015-01-01

    Inflammatory myofibroblastic tumor (IMT) and some types of immunoglobulin (Ig) G4-related disease are often involved in the spectrum of inflammatory pseudotumor (IPT) and the concept of IgG4-related IPT/IMT has recently been proposed. A 38-year-old man complained of initial symptoms of blurred vision and headache. A tumor was found in the right mastoid, which caused occlusion of the right sigmoid sinus and intracranial hypertension. A diagnosis of IMT with IgG4+ plasma cell infiltration was established by surgical, pathological, and immunohistochemistry findings. His symptoms were completely relieved after corticosteroid therapy and no recurrence was detected during 22 months of follow-up. A case with cerebral venous sinus infiltrated by IMTs in the head and neck has never been reported; corticosteroid therapy proved satisfactory in IMT with IgG4+ plasma cell infiltration. © 2014 Wiley Periodicals, Inc.

  20. Gene Therapy With Extracellular Superoxide Dismutase Protects Conscious Rabbits Against Myocardial Infarction

    PubMed Central

    Li, Qianhong; Bolli, Roberto; Qiu, Yumin; Tang, Xian-Liang; Guo, Yiru; French, Brent A.

    2013-01-01

    Background Extracellular superoxide dismutase (Ec-SOD) may protect the heart against myocardial infarction (MI) because of its extended half-life and capacity to bind heparan sulfate proteoglycans on cellular surfaces. Accordingly, we used direct gene transfer to increase systemic levels of Ec-SOD and determined whether this gene therapy could protect against MI. Methods and Results The cDNA for human Ec-SOD was incorporated into a replication-deficient adenovirus (Ad5/CMV/Ec-SOD). Injection of this virus produced a high level of Ec-SOD in the liver, which was redistributed to the heart and other organs by injection of heparin. Untreated rabbits (group I) underwent a 30-minute coronary occlusion and 3 days of reperfusion. For comparison, preconditioned rabbits (group II) underwent a sequence of six 4-minute-occlusion/4-minute-reperfusion cycles 24 hours before the 30-minute occlusion. Control-treated rabbits (group III) were injected intravenously with Ad5/CMV/nls-LacZ, and gene-therapy rabbits (group IV) were injected with Ad5/CMV/Ec-SOD 3 days before the 30-minute occlusion. Both groups treated with Ad5 received intravenous heparin 2 hours before the 30-minute occlusion. Infarct size (percent risk area) was similar in groups I (57±6%) and III (58±5%). Ec-SOD gene therapy markedly reduced infarct size to 25±4% (P<0.01, group IV versus group III), a protection comparable to that of the late phase of ischemic preconditioning (29±3%, P<0.01 group II versus group I). Conclusions Direct gene transfer of the cDNA encoding membrane-bound Ec-SOD affords powerful cardioprotection, providing proof of principle for the effectiveness of antioxidant gene therapy against MI. PMID:11294809

  1. Effects of Mandibular Retrusive Deviation on Prefrontal Cortex Activation: A Functional Near-Infrared Spectroscopy Study

    PubMed Central

    Otsuka, Takero; Yamasaki, Ryuichi; Shimazaki, Tateshi; Sasaguri, Kenichi; Kawata, Toshitsugu

    2015-01-01

    The objective of this study was to evaluate occlusal condition by assessing brain activity in the prefrontal cortex, which is associated with emotion. Functional near-infrared spectroscopy (fNIRS) was used to detect changes in cerebral blood flow in the prefrontal cortex of 12 healthy volunteers. The malocclusion model was a custom-made splint that forced the mandible into retrusion. A splint with no modification was used as a control. The cortical activation during clenching was compared between the retrusive position condition and the control condition. A visual analog scale score for discomfort was also obtained during clenching and used to evaluate the interaction between fNIRS data and psychiatric changes. Activation of the prefrontal cortex was significantly greater during clenching in the mandibular retrusive condition than during clenching in the control condition. Furthermore, Spearman rank-correlation coefficient revealed a parallel relation between prefrontal cortex activation and visual analog scale score for discomfort. These results indicate that fNIRS can be used to objectively evaluate the occlusal condition by evaluating activity in the prefrontal cortex. PMID:26075235

  2. Effects of mandibular retrusive deviation on prefrontal cortex activation: a functional near-infrared spectroscopy study.

    PubMed

    Otsuka, Takero; Yamasaki, Ryuichi; Shimazaki, Tateshi; Yoshino, Fumihiko; Sasaguri, Kenichi; Kawata, Toshitsugu

    2015-01-01

    The objective of this study was to evaluate occlusal condition by assessing brain activity in the prefrontal cortex, which is associated with emotion. Functional near-infrared spectroscopy (fNIRS) was used to detect changes in cerebral blood flow in the prefrontal cortex of 12 healthy volunteers. The malocclusion model was a custom-made splint that forced the mandible into retrusion. A splint with no modification was used as a control. The cortical activation during clenching was compared between the retrusive position condition and the control condition. A visual analog scale score for discomfort was also obtained during clenching and used to evaluate the interaction between fNIRS data and psychiatric changes. Activation of the prefrontal cortex was significantly greater during clenching in the mandibular retrusive condition than during clenching in the control condition. Furthermore, Spearman rank-correlation coefficient revealed a parallel relation between prefrontal cortex activation and visual analog scale score for discomfort. These results indicate that fNIRS can be used to objectively evaluate the occlusal condition by evaluating activity in the prefrontal cortex.

  3. Occlusal plane location in edentulous patients: a review.

    PubMed

    Shetty, Sanath; Zargar, Nazia Majeed; Shenoy, Kamalakanth; Rekha, V

    2013-09-01

    Occlusal plane orientation is an important factor in the construction of a complete denture. Occlusal plane could be oriented using landmarks in the mandibular arch as well as in the maxillary arch. In the mandibular arch there are few landmarks which could be used to orient the occlusal plane like the retromolar pad, corner of the lips (lower lip length) whereas the maxillary arch has a number of landmarks, of which the ala-tragal line is the most commonly used and the same being the most controversial. In the following article different landmarks and its accuracy for orientating the occlusal plane in an edentulous subject as studied by various authors has been discussed.

  4. Osteogenesis imperfecta with right renal artery occlusion

    PubMed Central

    Vaish, Arvind Kumar; Kumar, Nitin; Jain, Nirdesh; Agarwal, Abhishek

    2012-01-01

    We here report a case of osteogenesis imperfecta who presented with severe hypertension and left ventricular failure and had right renal artery occlusion. The case is very interesting as renal artery occlusion has not been reported earlier in osteogenesis imperfecta. PMID:22962392

  5. Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jambon, E.; Petitpierre, F.; Brizzi, V.

    PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomesmore » and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.« less

  6. A possible association of idiopathic osteosclerosis with excessive occlusal forces.

    PubMed

    Misirlioglu, Melda; Nalcaci, Rana; Baran, Ilgi; Adisen, Mehmet Zahit; Yilmaz, Selmi

    2014-03-01

    The aim of the study was to determine the relationship between idiopathic osteosclerotic lesions and occlusal forces using the T-Scan II computerized occlusal analysis device, and to test the sensitivity of the system in occlusal analysis. The study was conducted with 21 volunteers with idiopathic osteosclerosis (IO; 14 women, 7 men) aged between 17 and 62 years (mean 29.95). For every patient, seven or eight recordings were made with the T-Scan II occlusal analysis device in maximum intercuspation, and the last two (excluding any with technical problems) were chosen for evaluation. For each lesion-related area, the distribution of high occlusal forces from two different movies was analyzed. In 18 patients (85.71%), lesions were observed in an area of high occlusal force, and in 13 patients (61.9%), the lesions were located at the first area subjected to high occlusal forces. The percentage distribution of high forces at a lesion related area ranged from 0% to 88%. On average, the high forces at an osteosclerotic lesion area accounted for 20% of the maximum total force. No statistical differences were observed between the measurements of the two selected recordings (P > .05). The findings of this study suggest a possible relationship between IO and occlusal forces and primary contacts. T-Scan II was found to be a successful diagnostic device for detecting primary contacts and excessive occlusal forces.

  7. [Occlusion treatment for amblyopia. Age dependence and dose-response relationship].

    PubMed

    Fronius, M

    2016-04-01

    Based on clinical experience and studies on animal models the age of 6-7 years was regarded as the limit for treatment of amblyopia, although functional improvement was also occasionally reported in older patients. New technical developments as well as insights from clinical studies and the neurosciences have attracted considerable attention to this topic. Various aspects of the age dependence of amblyopia treatment are discussed in this article, e. g. prescription, electronic monitoring of occlusion dosage, calculation of indicators for age-dependent plasticity of the visual system, and novel, alternative treatment approaches. Besides a discussion of the recent literature, results of studies by our "Child Vision Research Unit" in Frankfurt are presented: results of a questionnaire about prescription habits concerning age limits of patching, electronic recording of occlusion in patients beyond the conventional treatment age, calculation of dose-response function and efficiency of patching and their age dependence. The results of the questionnaire illustrate the uncertainty about age limits of prescription with significant deviations from the guideline of the German Ophthalmological Society (DOG). Electronic recording of occlusion allowed the quantification of declining dose-response function and treatment efficiency between 5 and 16 years of age. Reports about successful treatment with conventional and novel methods in adults are at variance with the notion of a rigid adult visual system lacking plasticity. Electronic recording of patching allowed new insights into the age-dependent susceptibility of the visual system and contributes to a more evidence-based treatment of amblyopia. Alternative approaches for adults challenge established notions about age limits of amblyopia therapy. Further studies comparing different treatment options are urgently needed.

  8. Occlusal contact of fixed implant prostheses using functional bite impression technique.

    PubMed

    Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2015-02-01

    Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.

  9. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vessel occlusion transducer. 870.2890 Section 870.2890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion...

  10. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel occlusion transducer. 870.2890 Section 870.2890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion...

  11. A case of Churg-Strauss syndrome and central retinal artery occlusion with good visual recovery.

    PubMed

    Kamata, Yuki; Hashizume, Kouhei; Kaneko, Muneyoshi; Kurosaka, Daijiro

    2013-04-01

    Here we report a case of Churg-Strauss syndrome (CSS) and central retinal artery occlusion (CRAO), with good visual recovery. A 58-year-old Japanese man with CSS experienced acute painless loss of vision in his right eye. CRAO was diagnosed by fundoscopic findings (retinal whitening with a cherry-red spot). Steroid pulse therapy (methylprednisolone at 1 g daily for 3 days) followed by combined treatment with prednisolone (30 mg/day) and cyclophosphamide (150 mg/day) was administered; his visual acuity recovered to 20/30 in 1 month, and no recurrence has occurred for 1 year. Steroid pulse therapy may be effective for CRAO in CSS patients.

  12. Ocular vascular occlusive disorders: Natural history of visual outcome☆

    PubMed Central

    Hayreh, Sohan Singh

    2014-01-01

    Ocular vascular occlusive disorders collectively constitute the most common cause of visual disability. Before a disease can be managed, it is essential to understand its natural history, so as to be able to assess the likely effectiveness of any intervention. I investigated natural history of visual outcome in prospective studies of 386 eyes with non-arteritic anterior ischemic optic neuropathy (NA-AION), 16 eyes with non-arteritic posterior ischemic optic neuropathy, 697 eyes with central retinal vein occlusion (CRVO), 67 eyes with hemi-CRVO (HCRVO), 216 eyes with branch retinal vein occlusion (BRVO), 260 eyes with central retinal artery occlusion (CRAO), 151 eyes with branch retinal artery occlusion (BRAO) and 61 eyes with cilioretinal artery occlusion (CLRAO). My studies have shown that every one of these disorders consists of multiple distinct clinical sub-categories with different visual findings. When an ocular vascular occlusive disorder is caused by giant cell arteritis, which is an ophthalmic emergency, it would be unethical to do a natural history study of visual outcome in them, because in this case early diagnosis and immediate, intensive high-dose steroid therapy is essential to prevent any further visual loss, not only in the involved eye but also in the fellow, normal eye. In NA-AION in eyes seen ≤2 weeks after the onset, visual acuity (VA) improved in 41% of those with VA 20/70 or worse, and visual field (VF) improved in 26% of those with moderate to severe VF defect. In non-ischemic CRVO eyes with VA 20/70 or worse, VA improved in 47% and in ischemic CRVO in 23%; moderate to severe VF defect improved in 79% in non-ischemic CRVO and in 27% in ischemic CRVO. In HCRVO, overall findings demonstrated that initial VA and VF defect and the final visual outcome were different in non-ischemic from ischemic HCRVO – much better in the former than the latter. In major BRVO, in eyes with initial VA of 20/70 or worse, VA improved in 69%, and moderate to

  13. Workflow Optimization in Vertebrobasilar Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kamper, Lars, E-mail: lars.kamper@helios-kliniken.de; Meyn, Hannes; Rybacki, Konrad

    2012-06-15

    Objective: In vertebrobasilar occlusion, rapid recanalization is the only substantial means to improve the prognosis. We introduced a standard operating procedure (SOP) for interventional therapy to analyze the effects on interdisciplinary time management. Methods: Intrahospital time periods between hospital admission and neuroradiological intervention were retrospectively analyzed, together with the patients' outcome, before (n = 18) and after (n = 20) implementation of the SOP. Results: After implementation of the SOP, we observed statistically significant improvement of postinterventional patient neurological status (p = 0.017). In addition, we found a decrease of 5:33 h for the mean time period from hospital admissionmore » until neuroradiological intervention. The recanalization rate increased from 72.2% to 80% after implementation of the SOP. Conclusion: Our results underscore the relevance of SOP implementation and analysis of time management for clinical workflow optimization. Both may trigger awareness for the need of efficient interdisciplinary time management. This could be an explanation for the decreased time periods and improved postinterventional patient status after SOP implementation.« less

  14. Circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures: A randomized controlled clinical trial using cone beam computed tomography.

    PubMed

    Elsyad, Moustafa Abdou; Khirallah, Ahmed Samir

    2016-11-01

    Circumferential marginal bone around 2 splinted and nonsplinted immediately loaded implants in the edentulous mandible has not been previously investigated. The purpose of this randomized controlled clinical trial was to assess circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures, using cone beam computed tomography (CBCT). Thirty participants with complete edentulism were allocated to 2 groups and received 2 implants in the canine region of the mandible. Implants were either left nonsplinted (with ball attachment [BA]) or splinted (with bar attachment [RA]). Mandibular overdentures were connected to the implants 1 week later. CBCT was used to evaluate vertical bone loss (VBL) and horizontal bone loss (HBLo) bone loss at the distal (D), buccal (B), mesial (M), and lingual (L) sites of each implant upon overdenture insertion (baseline, T0), 1 year (T1) and 3 years (T3) after insertion. Repeated measures ANOVA was used for statistical analysis (α=.05). No significant difference in the survival rate (93.3% for BA and 100% for RA) was found between groups (P=.156). VBL and HBLo increased significantly at T3 compared with T1 for both groups (P<.005). After 3 years, VBL were 1.36 ±0.57 mm and 1.0 ±0.44 mm and HBLo were 0.88 ±0.48 mm for BA and 0.77 ±0.53 mm for RA. At T1 and T3, BA had more significant VBL than RA (P<.001), while HBLo did not differ significantly between groups. For both groups, a significant difference was found in VBL and HBLo between implant sites (P<.001). The B site recorded the highest VBL, and the L site recorded the lowest VBL. The M and D sites recorded the highest HBLo, and the B and L sites recorded the lowest HBLo. Two nonsplinted immediately loaded implants retaining mandibular overdentures were associated with significantly higher vertical and horizontal circumferential bone loss than those associated with splinted implants after a follow-up of 3 years. Copyright

  15. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  16. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  17. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  18. In vitro reproduction of incisal/occlusal cupping/cratering.

    PubMed

    Dzakovich, John J; Oslak, Robert R

    2013-06-01

    Occlusal cupping/cratering (depressed dentin surrounded by elevated rims of enamel) has been postulated to be the result of abrasion, bruxism, attrition, acid erosion, stress corrosion, or a combination of these. The primary etiology or the multifactorial sequence of occlusal cupping/cratering remains scientifically unsubstantiated. The purpose of this study was to reproduce occlusal/incisal cupping/cratering in vitro. This study was designed to create cupping/cratering on the occlusal surfaces of extracted human teeth rather than to quantify the amount of lost tooth structure caused by abrasion. One name-brand toothbrush was tested with 2 different dentifrices (of different abrasive potentials [low and high]) and water only (nonabrasive) on extracted human teeth. Six specimens of 4 teeth each (24 teeth) were subjected to horizontal brushing in a 1:1 toothpaste/water slurry and water only. The control group, brushed with water only, demonstrated no visible loss of tooth structure. Each of the specimens brushed with toothpaste, regardless of the degree of abrasivity, demonstrated visible wear of the dentin, resulting in occlusal/incisal cupping/cratering. Pronounced cupping/cratering was caused by horizontal brushing with commercial toothpastes. Brushing in water demonstrated no visual loss of occlusal tooth structure. (J Prosthet Dent 2013;109:384-391). Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  19. Endovascular Treatment of Veno-Occlusive Behcet's Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tekbas, Guven, E-mail: drgtekbas@gmail.com; Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Gur, Serkan, E-mail: mserkangur@yahoo.com

    Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet's disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18-76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd-Chiari syndrome (BCS; n = 2).more » All patients met criteria of the International Study Group on Behcet's Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.« less

  20. Combining technologies: a computerized occlusal analysis system synchronized with a computerized electromyography system.

    PubMed

    Kerstein, Robert B

    2004-04-01

    Current advances in computer technologies have afforded dentists precision ways to examine occlusal contacts and muscle function. Recently, two separate computer technologies have been synchronized together, so that an operator can record their separate diagnostic data simultaneously. The two systems are: the T Scan II Occlusal Analysis System and the Biopak Electromyography Recording System. The simultaneous recording and playback capacity of these two computer systems allows the operator to analyze and correlate specific occlusal moments to specific electromyographic changes that result from these occlusal moments. This synchronization provides unparalleled evidence of the effect occlusal contact arrangement has on muscle function. Therefore, the occlusal condition of an inserted dental prosthesis or the occlusal scheme of the natural teeth (before and after corrective occlusal adjustments) can be readily evaluated, documented, and quantified for both, quality of occlusal parameters and muscle activity and the responses to the quality of the occlusal condition. This article describes their synchronization and illustrates their use in performing precision occlusal adjustment procedures on two patients: one who demonstrates occlusal disharmony while exhibiting the signs and symptoms of chronic myofascial pain dysfunction syndrome, and the other who had extensive restorative work accomplished but exhibits occlusal discomfort post-operatively.

  1. Melorheostosis with occlusion of dorsalis pedis artery.

    PubMed

    Ishibe, Motomi; Inoue, Masayuki; Saitou, Katsutoshi

    2002-02-01

    Melorheostosis is an unusual sclerotic dysplasia of bone. The case of a 51-year-old female patient with melorheostosis and occlusion of the dorsalis pedis artery is described. Although numerous vascular anomalies have been noted in patients with melorheostosis, occlusion of the dorsalis pedis artery has not been reported previously.

  2. Amalric sign: An augur of ophthalmic artery occlusion

    PubMed Central

    Hande, Prathibha; Sinha, Babi; Nayak, Shivani; Srinivasan, Srilakshmi; Shetty, Jyothi

    2017-01-01

    A 75-year-old man presented to us with sudden onset of profound vision loss in his right eye and was identified as suffering from an ophthalmic artery occlusion. Apart from the retinal whitening and box-carring of the retinal arteries, there were characteristic triangular patches of retinal whitening in the midperipheral temporal fundus indicating a previous lateral posterior choroidal artery occlusion. The patient was a chronic smoker and had dyslipidemia. The carotid Doppler study showed complete occlusion of the internal carotid artery. The presence of these triangular patches of retinal whitening or amalric sign can therefore herald a more proximal vessel occlusion. Hence such patients require evaluation on an emergency basis. The characteristic features of the patches on fluorescein angiography and indocyanine green angiography are discussed here. PMID:29044080

  3. Amalric sign: An augur of ophthalmic artery occlusion.

    PubMed

    Hande, Prathibha; Sinha, Babi; Nayak, Shivani; Srinivasan, Srilakshmi; Shetty, Jyothi

    2017-10-01

    A 75-year-old man presented to us with sudden onset of profound vision loss in his right eye and was identified as suffering from an ophthalmic artery occlusion. Apart from the retinal whitening and box-carring of the retinal arteries, there were characteristic triangular patches of retinal whitening in the midperipheral temporal fundus indicating a previous lateral posterior choroidal artery occlusion. The patient was a chronic smoker and had dyslipidemia. The carotid Doppler study showed complete occlusion of the internal carotid artery. The presence of these triangular patches of retinal whitening or amalric sign can therefore herald a more proximal vessel occlusion. Hence such patients require evaluation on an emergency basis. The characteristic features of the patches on fluorescein angiography and indocyanine green angiography are discussed here.

  4. Extraluminal biodegradable splint to treat upper airway anterior malacia: A preclinical proof of principle.

    PubMed

    Gorostidi, François; Courbon, Cécile; Burki, Marco; Reinhard, Antoine; Sandu, Kishore

    2018-02-01

    Upper airway malacia highly complicates the treatment of benign laryngotracheal stenosis, and no ideal option is available to date. We here explore the use of extraluminal biodegradable splints in an animal model of long-segment anterior tracheomalacia (TM). We show the efficacy, as well as the tissue tolerance, of a custom-made biodegradable extraluminal device surgically inserted around the trachea. Preclinical animal study. Anterior TM was induced in rabbits through an anterior neck approach by removing eight consecutive anterior tracheal rings without damaging the underlying mucosa. Malacia was corrected during the same surgery by pexy sutures, suspending the tracheal mucosa to an experimental biodegradable device. Symptoms, survival, and tissue reaction were compared to healthy and sham surgery controls. The model induced death by respiratory failure within minutes. Ten animals received the experimental treatment, and those who survived the perioperative period remained asymptomatic with a maximum follow-up of 221 days. Histological studies at programmed euthanasia showed complete degradation of the prosthesis, with significant remnant fibrosis around the trachea. However, the tracheal stiffness of test segments was comparatively less than that of control segments. Extraluminal biodegradable splints rescued animals with a condition otherwise incompatible with life. It was well tolerated, leaving peritracheal fibrosis that was not as stiff as normal trachea. The external tracheal stiffening was sufficient for the test animals to live through the phase of severe acute hypercollapsibility. This represents a valid option to help pediatric patients with laryngotracheal stenosis and associated cartilaginous airway malacia. NA. Laryngoscope, 128:E53-E58, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.

    PubMed

    Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan

    2008-01-01

    To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.

  6. Mandibular body fracture repair with wire-reinforced interdental composite splint in small dogs.

    PubMed

    Guzu, Michel; Hennet, Philippe R

    2017-11-01

    To report the outcome of mandibular body fractures treated with a wire-reinforced interdental composite splint (WRICS) in small breed dogs. Retrospective case series. Client-owned small breed dogs (n = 24). Medical records (1998-2012) of small breed dogs (<10 kg) with mandibular body fractures treated by WRICS were reviewed for signalment, history, type of fracture, treatment, and clinical and radiological follow-up. The angle of the fracture line (ANG) was measured on dental radiographs. A mandibular injury severity score (MISS) and a dental injury score (DIS) were evaluated as potential prognostic factors. Fractures most commonly involved P4-M1 (56%), and healed in a mean time of 2.37 ± 0.7 months. Healing was slower (P = .012) if teeth were present in the fracture line and required extraction, hemisection, or root canal therapy prior to WRICS placement (2.39 ± 0.7 months) than if no dental treatment was required (1.46 ± 0.8 months). Contrary to the MISS, the DIS was associated with longer time to bone healing (P = .001; r = .63) and risk of complications (P = .004). Bone healing time was decreased (P = .003; r = .61) with increasing fracture angles. WRICS can be considered to treat mandibular body fractures in small breed dogs if the fracture is not severely comminuted, and if at least the canine and first molar tooth can be used for anchorage. More severe lesions, such as those with teeth in the fracture line and a shorter fracture surface, are associated with prolonged bone healing. © 2017 The American College of Veterinary Surgeons.

  7. Progression of Diabetic Capillary Occlusion: A Model

    PubMed Central

    Gens, John Scott; Glazier, James A.; Burns, Stephen A.; Gast, Thomas J.

    2016-01-01

    An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions. PMID:27300722

  8. Acute painless monocular visual loss due to central retinal artery occlusion in a patient with Churg-Strauss vasculitis.

    PubMed

    Skrapari, Ioanna; Kagkelari, Eleftheria; Charitatos, Evangelos; Pantelidaki, Catherine; Gounaris, Theodoros; Sioula, Evagelia

    2008-01-01

    Ocular involvement in Churg-Strauss syndrome (CSS) is infrequent. We describe a case of a 50-year-old woman, with blood eosinophilia, involvement of the respiratory tract, skin, and peripheral nervous system, fulfilling the American College of Rheumatology criteria for CSS, who presented with left foot drop followed by left acute painless visual loss. Central retinal artery occlusion was diagnosed by fundoscopic findings (retinal whitening with a cherry-red spot). CSS was confirmed by sural nerve biopsy. Despite treatment with high-dose corticosteroids, cyclophosphamide, and anticoagulant therapy, visual acuity was not substantially improved. Acute blindness in CSS has been rarely described. Even more rarely, central retinal artery occlusion has been found to be the underlying cause of this infrequent clinical manifestation in CSS.

  9. Retinal vein occlusion

    MedlinePlus

    ... of one eye. Exams and Tests Tests to evaluate for vein occlusion include: Exam of the retina after dilating the pupil An eye test that uses a special dye and camera to look at blood flow in the retina and choroid. Intraocular pressure Pupil ...

  10. Role of occlusion in endodontic management: report of two cases.

    PubMed

    Yu, Christine Y

    2004-12-01

    The two clinical cases reported demonstrate that traumatic occlusion can play a role in the initiation and progression of pulp and periradicular inflammation. The symptom of persistent pain did not subside after the commencement of endodontic treatment. Traumatic occlusion was identified in both cases to be the main cause and hence occlusal adjustment was performed. This resulted in the gradual resolution of the symptoms. The findings suggest that occlusal trauma is often overlooked in the diagnosis and management of endodontic diseases.

  11. Haptic simulation framework for determining virtual dental occlusion.

    PubMed

    Wu, Wen; Chen, Hui; Cen, Yuhai; Hong, Yang; Khambay, Balvinder; Heng, Pheng Ann

    2017-04-01

    The surgical treatment of many dentofacial deformities is often complex due to its three-dimensional nature. To determine the dental occlusion in the most stable position is essential for the success of the treatment. Computer-aided virtual planning on individualized patient-specific 3D model can help formulate the surgical plan and predict the surgical change. However, in current computer-aided planning systems, it is not possible to determine the dental occlusion of the digital models in the intuitive way during virtual surgical planning because of absence of haptic feedback. In this paper, a physically based haptic simulation framework is proposed, which can provide surgeons with the intuitive haptic feedback to determine the dental occlusion of the digital models in their most stable position. To provide the physically realistic force feedback when the dental models contact each other during the searching process, the contact model is proposed to describe the dynamic and collision properties of the dental models during the alignment. The simulated impulse/contact-based forces are integrated into the unified simulation framework. A validation study has been conducted on fifteen sets of virtual dental models chosen at random and covering a wide range of the dental relationships found clinically. The dental occlusions obtained by an expert were employed as a benchmark to compare the virtual occlusion results. The mean translational and angular deviations of the virtual occlusion results from the benchmark were small. The experimental results show the validity of our method. The simulated forces can provide valuable insights to determine the virtual dental occlusion. The findings of this work and the validation of proposed concept lead the way for full virtual surgical planning on patient-specific virtual models allowing fully customized treatment plans for the surgical correction of dentofacial deformities.

  12. Evaluation of the occlusal contact of crowns fabricated with the bite impression method.

    PubMed

    Makino, Sachi; Okada, Daizo; Shin, Chiharu; Ogura, Reiko; Ikeda, Masaomi; Miura, Hiroyuki

    2013-09-30

    In prosthodontic treatment, reconstruction of a proper occlusal contact relationship is very important as well as reconstruction of a proper interproximal relationship and marginal fitness. Unfortunately, occlusal relationships are sometimes lost in the process of occlusal adjustment of crowns. The purpose of this study was to compare the occlusal contacts of single crown fabricated by two different types of impression techniques. Nine subjects, whose molars required treatment with crown restoration, were enrolled in this study. Full cast crowns were fabricated using two types of impression techniques: the conventional impression method (CIM) and the bite impression method (BIM). The occlusal contacts of crowns were precisely evaluated at the following stages: after occlusal adjustment on the articulator (Step 0), before occlusal adjustment in the mouth (Step 1), after occlusal adjustment at the intercuspal position (Step 2), and after occlusal adjustment during lateral and protrusive excursions (Step 3). The number of occlusal contacts of the crowns on the functional cusps fabricated with BIM was significantly greater than that with CIM after occlusal adjustment. For this reason, the crowns fabricated with BIM might have a more functionally desirable occlusal surface compared to the crowns fabricated with CIM.

  13. [Comparison of 2 lacrimal punctal occlusion methods].

    PubMed

    Shalaby, O; Rivas, L; Rivas, A I; Oroza, M A; Murube, J

    2001-09-01

    To study and compare two methods for canalicular occlusion: Cautery and Punctal Patch. The study included fourty patients divided in two groups of 20 patients. The end point was 4 occluded puncti. The first group underwent deep cauterization resulting in occlusion of the full vertical aspect of the canaliculus. The second group underwent punctal patch technique for canalicular occlusion. Differential parameters were the following: time of intervention, ease of use, risks and precision. In the post operatory, discomfort, subjective and objective improvement in ocular surface as well as long term result of each technique was analysed. Time of intervention was longer for punctal patch compared to cautery. Both methods exhibited similar ease of use and improvement in ocular surface. Precision was high in punctal patch technique showing complete and final occlusion and no punctum needed reopening, while cautery technique presented 20% rate of reopening intervention. Postoperatory discomfort and irritation were remarkably evident with punctal technique, while minimal in cautery technique. Survival analysis after one year follow up, showed a higher rate of advantages for punctal patch technique over cautery technique.

  14. Massage treatment and medial tibial stress syndrome; A commentary to provoke thought about the way massage therapy is used in the treatment of MTSS.

    PubMed

    Fogarty, Sarah

    2015-07-01

    As students and practitioners we are taught about the treatment and causative factors of medial shin pain, in particular' shin splints' or the more recent term; medial tibial stress syndrome (MTSS). During the years there have been many theories, conjecture and misunderstandings about the mechanisms of 'shin splints/medial tibial stress syndrome' however the ramifications of these mechanisms on how massage treatment is delivered have not being discussed. The evidence for the treatment of MTSS is largely clinical with little evidence of any treatment being proven to be effective in treating MTSS. The aim of this article is to present a summary of the mechanisms of MTSS and a commentary to provoke thought about the way massage therapy is used in the treatment of MTSS based on these mechanisms. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. ISCHEMIC CENTRAL RETINAL VEIN OCCLUSION IN THE ANTI-VASCULAR ENDOTHELIAL GROWTH FACTOR ERA.

    PubMed

    Tam, Emily K; Golchet, Pamela; Yung, Madeline; DeCroos, Francis C; Spirn, Marc; Lehmann-Clarke, Lydia; Ambresin, Aude; Tsui, Irena

    2018-02-01

    Anti-vascular endothelial growth factor therapy has improved the prognosis for patients with central retinal vein occlusion (CRVO). However, most studies published to date exclude ischemic CRVO. The purpose of this study was to describe the outcome in eyes with ischemic CRVO treated with anti-vascular endothelial growth factor therapy. Thirty-seven patients with ischemic CRVO from 3 centers were followed for at least 6 months. Data on patient demographic, vision status, and anti-vascular endothelial growth factor treatments were collected. Average number of injections during the study period was 5. Younger age was associated with improved vision (P = 0.006). Patients with improved visual outcomes tended to have macular edema as the primary indication for treatment, whereas patients with worse outcomes tended to have neovascularization as the primary indication for treatment. This study highlights significant variability in the use of anti-vascular endothelial growth factor therapy for ischemic CRVO and underscores that eyes with neovascularization tend to have worse visual outcomes.

  16. Collateral Circulation in Chronic Total Occlusions - an interventional perspective.

    PubMed

    Choo, Gim-Hooi

    2015-09-09

    Human coronary collaterals are inter-coronary communications that are believed to be present from birth. In the presence of chronic total occlusions, recruitment of flow via these collateral anastomoses to the arterial segment distal to occlusion provide an alternative source of blood flow to the myocardial segment at risk. This mitigates the ischemic injury. Clinical outcome of coronary occlusion ie. severity of myocardial infarction/ischemia, impairment of cardiac function and possibly survival depends not only on the acuity of the occlusion, extent of jeopardized myocardium, duration of ischemia but also to the adequacy of collateral circulation. Adequacy of collateral circulation can be assessed by various methods. These coronary collateral channels have been used successfully as a retrograde access route for percutaneous recanalization of chronic total occlusions. Factors that promote angiogenesis and further collateral remodeling ie. arteriogenesis have been identified. Promotion of collateral growth as a therapeutic target in patients with no suitable revascularization option is an exciting proposal.

  17. Acute pancreatitis during sickle cell vaso-occlusive painful crisis.

    PubMed

    Ahmed, Shahid; Siddiqui, Anita K; Siddiqui, Rina K; Kimpo, Miriam; Russo, Linda; Mattana, Joseph

    2003-07-01

    Sickle cell disease is characterized by chronic hemolytic anemia and vaso-occlusive painful crisis. The vascular occlusion in sickle cell disease is a complex process and accounts for the majority of the clinical manifestations of the disease. Abdominal pain is an important component of vaso-occlusive painful crisis and may mimic diseases such as acute appendicitis and cholecystitis. Acute pancreatitis is rarely included as a cause of abdominal pain in patients with sickle cell disease. When it occurs it may result form biliary obstruction, but in other instances it might be a consequence of microvessel occlusion causing ischemia. In this series we describe four cases of acute pancreatitis in patients with sickle cell disease apparently due to microvascular occlusion and ischemic injury to the pancreas. All patients responded to conservative management. Acute pancreatitis should be considered in the differential diagnosis of abdominal pain in patients with sickle cell disease. Copyright 2003 Wiley-Liss, Inc.

  18. Hand Therapy

    MedlinePlus

    ... a scar Find a hand surgeon near you. Videos Figures Figure 1: Examples of hand splints PDF ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  19. Catheter-less robotic radical prostatectomy using a custom-made synchronous anastomotic splint and vesical urinary diversion device: report of the initial series and perioperative outcomes.

    PubMed

    Tewari, Ashutosh; Rao, Sandhya; Mandhani, Anil

    2008-09-01

    To study the feasibility of avoiding a urethral catheter after robotic radical prostatectomy by using suprapubic diversion with a urethral splint, as urethral catheterization is often a source of major discomfort and pain to the patient, and can cause more concern to the patient than the procedure; we present the outcomes of a pilot study. This pilot study involved 30 patients; in group 1 (the study group of 10 patients) we used a custom-made suprapubic catheter which provided a small anastomotic splint, multiple holes for drainage and the ability to retract the splint to give a voiding trial before removing the drainage device. Group 2 was a control group of 20 patients who had standard urethral catheterization with an 18 F Silastic Foley catheter. Demographic, intraoperative and outcome data were measured and analysed. Urethral symptoms were recorded using a specially developed questionnaire. The two groups were comparable in terms of age, serum prostate specific antigen level, body mass index, Gleason scores, tumour stage, operative duration, amount of bleeding, console times, anastomotic leakage and postoperative retention rates. The study group had significantly less penile shaft or tip pain and discomfort during walking or sleeping. No patient in either group had haematuria or clot retention requiring irrigation. Urethral catheter-less robotic radical prostatectomy is feasible. The advantages are decreased penile shaft and tip pain, and decreased patient discomfort and an earlier return of continence.

  20. Computational evaluation of aortic occlusion and the proposal of a novel, improved occluder: Constrained endo-aortic balloon occlusion.

    PubMed

    de Vaal, M H; Gee, M W; Stock, U A; Wall, W A

    2016-12-01

    Because aortic occlusion is arguably one of the most dangerous aortic manipulation maneuvers during cardiac surgery in terms of perioperative ischemic neurological injury, the purpose of this investigation is to assess the structural mechanical impact resulting from the use of existing and newly proposed occluders. Existing (clinically used) occluders considered include different cross-clamps (CCs) and endo-aortic balloon occlusion (EABO). A novel occluder is also introduced, namely, constrained EABO (CEABO), which consists of applying a constrainer externally around the aorta when performing EABO. Computational solid mechanics are employed to investigate each occluder according to a comprehensive list of functional requirements. The potential of a state of occlusion is also considered for the first time. Three different constrainer designs are evaluated for CEABO. Although the CCs were responsible for the highest strains, largest deformation, and most inefficient increase of the occlusion potential, it remains the most stable, simplest, and cheapest occluder. The different CC hinge geometries resulted in poorer performance of CC used for minimally invasive procedures than conventional ones. CEABO with a profiled constrainer successfully addresses the EABO shortcomings of safety, stability, and positioning accuracy, while maintaining its complexities of operation (disadvantage) and yielding additional functionalities (advantage). Moreover, CEABO is able to achieve the previously unattainable potential to provide a clinically determinable state of occlusion. CEABO offers an attractive alternative to the shortcomings of existing occluders, with its design rooted in achieving the highest patient safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Influence of occlusal contact area on cusp defection and stress distribution.

    PubMed

    Costa, Anna Karina Figueiredo; Xavier, Thaty Aparecida; Paes-Junior, Tarcisio José Arruda; Andreatta-Filho, Oswaldo Daniel; Borges, Alexandre Luiz Souto

    2014-11-01

    The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental

  2. Pathophysiological mechanisms of high-intensity focused ultrasound-mediated vascular occlusion and relevance to non-invasive fetal surgery

    PubMed Central

    Shaw, C. J.; ter Haar, G. R.; Rivens, I. H.; Giussani, D. A.; Lees, C. C.

    2014-01-01

    High-intensity focused ultrasound (HIFU) is a non-invasive technology, which can be used occlude blood vessels in the body. Both the theory underlying and practical process of blood vessel occlusion are still under development and relatively sparse in vivo experimental and therapeutic data exist. HIFU would however provide an alternative to surgery, particularly in circumstances where serious complications inherent to surgery outweigh the potential benefits. Accordingly, the HIFU technique would be of particular utility for fetal and placental interventions, where open or endoscopic surgery is fraught with difficulty and likelihood of complications including premature delivery. This assumes that HIFU could be shown to safely and effectively occlude blood vessels in utero. To understand these mechanisms more fully, we present a review of relevant cross-specialty literature on the topic of vascular HIFU and suggest an integrative mechanism taking into account clinical, physical and engineering considerations through which HIFU may produce vascular occlusion. This model may aid in the design of HIFU protocols to further develop this area, and might be adapted to provide a non-invasive therapy for conditions in fetal medicine where vascular occlusion is beneficial. PMID:24671935

  3. Venous sinus occlusive disease: MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuh, W.T.C.; Simonson, T.M.; Tali, E.T.

    1994-02-01

    To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attention to mass effect, hemorrhage, and T2-weighted image abnormalities as well as to abnormal parenchymal, venous, or arterial enhancement after intravenous gadopentetate dimeglumine administration. Follow-up studies when available were evaluated for atrophy, infraction, chronic mass effect, and hemorrhage. Mass effect was present in 25 of 26more » patients. Eleven of the 26 had mass effect without abnormal signal on T2-weighted images. Fifteen patients had abnormal signal on T2-weighted images, but this was much less extensive than the degree of brain swelling in all cases. No patient showed abnormal parenchymal or arterial enhancement. Abnormal venous enhancement was seen in 10 of 13 patients who had contrast-enhanced studies. Intraparenchymal hemorrhage was seen in nine patients with high signal on T2-weighted images predominantly peripheral to the hematoma in eight. Three overall MR patterns were observed in acute sinus thrombosis: (1) mass effect without associated abnormal signal on T2-weighted images, (2) mass effect with associated abnormal signal on T2-weighted images and/or ventricular dilatation that may be reversible, and (3) intraparenchymal hematoma with surrounding edema. MR findings of venus sinus occlusive disease are different from those of arterial ischemia and may reflect different underlying pathophysiology. In venous sinus occlusive disease, the breakdown of the blood-brain barrier (vasogenic edema and abnormal parenchymal enhancement) does not always occur, and brain swelling can persist up to 2 years with or without abnormal signal on T2-weighted images. 34 refs., 5 figs.« less

  4. Management of acute basilar artery occlusion: should any treatment strategy prevail?

    PubMed

    Dornak, Tomas; Herzig, Roman; Sanak, Daniel; Skoloudik, David

    2014-12-01

    Acute basilar artery occlusion (BAO) is relatively infrequent form of acute ischemic stroke associated with severe and persisting neurological deficit and high mortality rate (to 86%). Early recanalization is essential for good clinical outcome but the most effective treatment approach remains unestablished. Several treatment strategies are currently available but their safety and efficacy have only been tested in retrospective/prospective case series. Randomized controlled trials (RCTs) are lacking. We searched the PubMed database for assessments of recanalization rate and clinical outcome in BAO patients treated with various treatment methods. The results show that antithrombotics are least effective while specific reperfusion therapies including intravenous thrombolysis (IVT) and various types of intra-arterial therapy (IAT) are more so. Less than half of BAO patients reach independent outcome following IVT with a recanalization rate 52-78%. Even though IAT recanalizes BAO more frequently (in up to 100%), the higher recanalization rate is not necessarily associated with better outcome. Good clinical outcome is strongly dependent on recanalization time. Thus, the concept of bridging therapy, combining widely available IVT with IAT, was introduced and is usually considered a rescue strategy in non-responders to IV alteplase. A trend to better outcome in patients treated with bridging therapy in some studies, has to be confirmed by large RCTs.

  5. Dynamic Modelling of Tooth Deformation Using Occlusal Kinematics and Finite Element Analysis.

    PubMed

    Benazzi, Stefano; Nguyen, Huynh Nhu; Kullmer, Ottmar; Kupczik, Kornelius

    2016-01-01

    Dental biomechanics based on finite element (FE) analysis is attracting enormous interest in dentistry, biology, anthropology and palaeontology. Nonetheless, several shortcomings in FE modeling exist, mainly due to unrealistic loading conditions. In this contribution we used kinematics information recorded in a virtual environment derived from occlusal contact detection between high resolution models of an upper and lower human first molar pair (M1 and M1, respectively) to run a non-linear dynamic FE crash colliding test. MicroCT image data of a modern human skull were segmented to reconstruct digital models of the antagonistic right M1 and M1 and the dental supporting structures. We used the Occlusal Fingerprint Analyser software to reconstruct the individual occlusal pathway trajectory during the power stroke of the chewing cycle, which was applied in a FE simulation to guide the M1 3D-path for the crash colliding test. FE analysis results showed that the stress pattern changes considerably during the power stroke, demonstrating that knowledge about chewing kinematics in conjunction with a morphologically detailed FE model is crucial for understanding tooth form and function under physiological conditions. Results from such advanced dynamic approaches will be applicable to evaluate and avoid mechanical failure in prosthodontics/endodontic treatments, and to test material behavior for modern tooth restoration in dentistry. This approach will also allow us to improve our knowledge in chewing-related biomechanics for functional diagnosis and therapy, and it will help paleoanthropologists to illuminate dental adaptive processes and morphological modifications in human evolution.

  6. Pancreatitis in the Setting of Vaso-occlusive Sickle Cell Crisis: A Rare Encounter.

    PubMed

    Hasan, Badar; Asif, Talal; Braun, Cody; Bahaj, Waled; Dosokey, Eslam; Pauly, Rebecca R

    2017-04-25

    Acute pancreatitis is a common cause of acute abdominal pain. Gallstones and alcohol abuse account for the majority of the cases. Pancreatic ischemia is an uncommon but established cause of pancreatitis associated with connective tissue diseases, vasculitis, and shock. Our case highlights a rare case of vaso-occlusive crisis (VOC) in a patient with sickle cell (SC) disease leading to pancreatitis. Treatment remains largely conservative but exchange transfusion may be the therapy of choice in severely hypoxic patients or in patients with high pre-treatment hemoglobin S levels.

  7. Compliance with the prescribed occlusion treatment for amblyopia.

    PubMed

    Vagge, Aldo; Nelson, Leonard B

    2017-09-01

    The present review article is an update on the current evidence about compliance to the prescribed occlusion treatment for amblyopia. In particular, the authors focus on the predictors and causes of noncompliance and possible interventions to increase it. Compliance with prescribed occlusion treatment is often challenging. Reported rates of compliance range widely from 49% to 87%. Objective monitoring of occlusion has opened up new research opportunities and allow the design of effective therapeutic regimens. Also, predictors and causes of noncompliance have been investigated and their knowledge may help the clinician to improved compliance with prescribed occlusion treatment for amblyopia. Although many of the studies assessing the effectiveness of interventions to increase compliance to patching treatment for amblyopia have many limitations, evidences support that use of educational supports, parents, and patient understanding on the importance of patching and written information should be considered to increase compliance with patching.

  8. Effects of injection-site splinting on the incidence of phlebitis in patients taking peripherally infused amiodarone: A randomized clinical trial.

    PubMed

    Ayat-Isfahani, Farah; Pashang, Mina; Davoudi, Bita; Sadeghian, Saeed; Jalali, Arash

    2017-03-01

    Intravenous amiodarone is considered an effective treatment option for cardiac ventricular and atrial arrhythmias. Peripheral infusion of amiodarone may cause blood vessels irritation and phlebitis that is the most common complication of this drug by this route even when it is administered within recommended dosing limits. The effect of injection-site splinting on the occurrence of phlebitis among a group of cardiac arrhythmia patients receiving peripherally infused amiodarone. This research is a clinical trial on patients of Tehran Heart Center who were hospitalized due to cardiac arrhythmias. A sample of 60 patients with mean age 65 ± 14 years were randomly divided into control and test groups. In the experimental group with close splint and restrict the movement of the injection site until the end of the infusion and control groups without closing brace, at the same time received amiodarone. Injection protocol was similar for both groups. The results were analyzed with Spss18. The results of this research still significantly reduced the incidence of amiodarone injection-site phlebitis in the injection time (P = .005). Copyright © 2016 Society for Vascular Nursing, Inc. Published by Elsevier Inc. All rights reserved.

  9. Automated vision occlusion-timing instrument for perception-action research.

    PubMed

    Brenton, John; Müller, Sean; Rhodes, Robbie; Finch, Brad

    2018-02-01

    Vision occlusion spectacles are a highly valuable instrument for visual-perception-action research in a variety of disciplines. In sports, occlusion spectacles have enabled invaluable knowledge to be obtained about the superior capability of experts to use visual information to guide actions within in-situ settings. Triggering the spectacles to occlude a performer's vision at a precise time in an opponent's action or object flight has been problematic, due to experimenter error in using a manual buttonpress approach. This article describes a new laser curtain wireless trigger for vision occlusion spectacles that is portable and fast in terms of its transmission time. The laser curtain can be positioned in a variety of orientations to accept a motion trigger, such as a cricket bowler's arm that distorts the lasers, which then activates a wireless signal for the occlusion spectacles to change from transparent to opaque, which occurs in only 8 ms. Results are reported from calculations done in an electronics laboratory, as well as from tests in a performance laboratory with a cricket bowler and a baseball pitcher, which verified this short time delay before vision occlusion. In addition, our results show that occlusion consistently occurred when it was intended-that is, near ball release and during mid-ball-flight. Only 8% of the collected data trials were unusable. The laser curtain improves upon the limitations of existing vision occlusion spectacle triggers, indicating that it is a valuable instrument for perception-action research in a variety of disciplines.

  10. Virtual occlusal definition for orthognathic surgery.

    PubMed

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. On the relevance of "ideal" occlusion concepts for incisor inclination target definition.

    PubMed

    Knösel, Michael; Jung, Klaus

    2011-11-01

    The concept of "ideal" occlusion in harmony with craniofacial structures is often proposed as an ultimate goal of orthodontic treatment. The aim of this study was to assess the impact of slight variations in posterior occlusion and the history of straight-wire orthodontic treatment on the predictability of incisor inclination and third-order angles. Axial incisor inclinations, third-order angles, and craniofacial relationships were assessed on lateral headfilms and corresponding dental casts of 75 healthy white subjects, 16 to 26 years old, selected by the general inclusion criterion of a good interincisal relationship. Four groups were formed: group A (n = 17), Angle Class I occlusion subjects with no orthodontic treatment; group B (n = 20), Angle Class I occlusion subjects treated with standardized straight-wire orthodontics; group C (n = 20), up to a half-cusp distal occlusion after straight-wire treatment; and group D (n = 18), up to a half-cusp distal occlusion and no orthodontic treatment. Regression analysis was used to insert predictor angles into selected regression equations of the subjects with "ideal" occlusion, and the absolute differences between predicted and observed response angles were determined. Small differences in incisor inclination were found between subjects with "ideal" occlusion and those who slightly deviated from "ideal" with a mild occlusion of the Angle Class II category. Posterior occlusion was not relevant to the validity of the vast majority of predictor-response pairs. Straight-wire treatment produced incisor inclination that was slightly protruded compared with subjects who had good natural occlusion. The "ideal" posterior occlusion concepts as a general orthodontic treatment goal should be reconsidered. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  12. The effects of oral appliance therapy on occlusal function in patients with obstructive sleep apnea: a short-term prospective study.

    PubMed

    Otsuka, Ryo; Almeida, Fernanda Ribeiro; Lowe, Alan A

    2007-02-01

    The aim of this study was to objectively and prospectively assess whether oral appliances (OAs) alter occlusal function in patients treated for snoring or obstructive sleep apnea. The occlusal contact area (OCA) and bite force (Bf) of 12 patients who used OAs were measured with pressure-sensitive sheets in the morning and evening with the Dental Prescale Occluzer System. OCA and Bf were compared in each measurement period by using ANOVA. Percentage changes in the morning relative to the evening (OCA(M-E) and Bf(M-E)) were compared between the 2 periods by using the Wilcoxon signed rank test. Correlations between percentage changes in pretreatment and posttitration ((Pre-Post)OCA and (Pre-Post)Bf), age, and cephalometric variables were also assessed. Patients showed significant decreases in OCA and Bf when posttitration readings were compared with corresponding pretreatment measurements. OCA(M-E) and Bf(M-E) were significantly different between pretreatment and posttitration, suggesting that OCA and Bf tend to be smaller in the morning with OA use. (Pre-Post)Bf measured in the evening correlated with age. Effects on occlusal function after OA use were observed. These results suggest that practitioners should pay attention to the possible side effects of OAs on the dentition when treating patients with snoring or obstructive sleep apnea.

  13. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    PubMed

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  14. Mechanism of vaso-occlusion in sickle cell anemia

    NASA Astrophysics Data System (ADS)

    Lei, Huan; Karniadakis, George

    2012-11-01

    Vaso-occlusion crisis is one of the key hallmark of sickle cell anemia. While early studies suggested that the crisis is caused by blockage of a single elongated cell, recent experimental investigations indicate that vaso-occlusion is a complex process triggered by adhesive interactions among different cell groups in multiple stages. Based on dissipative particle dynamics, a multi-scale model for the sickle red blood cells (SS-RBCs), accounting for diversity in both shapes and cell rigidities, is developed to investigate the mechanism of vaso-occlusion crisis. Using this model, the adhesive dynamics of single SS-RBC was investigated in arterioles. Simulation results indicate that the different cell groups (deformable SS2 RBCs, rigid SS4 RBCs, leukocytes, etc.) exhibit heterogeneous adhesive behavior due to the different cell morphologies and membrane rigidities. We further simulate the tube flow of SS-RBC suspensions with different cell fractions. The more adhesive SS2 cells interact with the vascular endothelium and further trap rigid SS4 cells, resulting in vaso-occlusion in vessels less than 15 μm . Under inflammation, adherent leukocytes may also trap SS4 cells, resulting in vaso-occlusion in even larger vessels. This work was supported by the NSF grant CBET-0852948 and the NIH grant R01HL094270.

  15. Occlusal tooth wear in Chinese adults with shortened dental arches.

    PubMed

    Zhang, Q; Witter, D J; Bronkhorst, E M; Bartlett, D W; Creugers, N H J

    2014-02-01

    To assess associations between occlusal tooth wear and shortened dental arches (SDA) in Chinese 40 years and older subjects. From a sample of 1462 urban and rural adults, those presenting with SDA (n = 150) were compared with a control group of 65 randomly selected subjects with complete dentitions (CDA). Occlusal wear was assessed using a modified Smith and Knight index - the occlusal tooth wear index (OWTI) - and analysed using multivariate (logistic) regression. There was no significant effect from SDA on severe occlusal wear (OTWI score 3 or 4: OR = 2.016; 95% CI = 0.960-4.231; P = 0.064). Higher age was associated with severe occlusal wear (P values ≤0.007) and with higher mean OTWI scores; urban had less often severe occlusal wear than rural residents (OR = 0.519; P = 0.008). Higher mean OTWI scores were associated with rural residents, except for anterior teeth. Females had lower mean OTWI score for anterior teeth (effect = -0.153; P = 0.030). Premolars in SDA had higher mean OTWI scores compared with those in CDA (effect = +0.213; P = 0.006). In SDA, more posterior occluding pairs (POPs) were associated with lower mean OTWI sores for anterior teeth (effect: -0.158; P = 0.008) and higher scores for molars (effect: +0.249, P = 0.003). Subjects with SDA or CDA presented comparable occlusal wear, but premolars in SDA tend to have higher probability for having occlusal wear. Fewer numbers of POPs were associated with more wear in anterior teeth. © 2013 John Wiley & Sons Ltd.

  16. Striae and Their Relation to Topical Steroid Therapy

    PubMed Central

    Adam, J. E.; Craig, Gibson

    1965-01-01

    Atrophic striae have been reported to occur normally in 35% of adolescents and abnormally in a variety of medical conditions. Recently, the occurrence of striae has been observed in adults after the use of potent topical steroids with occlusion. Pre-existing striae have been found to enlarge after topical steroid therapy, even without occlusion. The mechanism of striae formation appears to be due to the action of the steroids on the dermal connective tissue and/or dermal matrix rather than to mechanical tension. ImagesFig. 1Fig. 2 PMID:14270214

  17. Pulmonary veno-occlusive disease and pulmonary capillary hemangiomatosis.

    PubMed

    Ortiz-Bautista, Carlos; Hernández-González, Ignacio; Escribano-Subías, Pilar

    2017-03-22

    Pulmonary veno-occlusive disease is a rare cause of pulmonary hypertension which is part, together with pulmonary capillary hemangiomatosis, of the special designation (subgroup 1') within pulmonary hypertension group 1 in the latest classification of the pulmonary hypertension World Symposium. Recent discovery that gene mutations in eukaryotic translation initiation factor 2 alpha kinase 4 (EIF2AK4) are responsible for inherited forms of pulmonary veno-occlusive disease has changed the role of genetic testing, acquiring relevant importance in the diagnosis of these patients. Despite the advances in genetic, cellular and molecular basis knowledge in the last decade, pulmonary veno-occlusive disease remains as a rare aetiology of pulmonary hypertension without any effective medical treatment approved and poor outcomes. This document aims to review the advances occurred in the understanding of pulmonary veno-occlusive disease in the last years. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  18. Vasculitic central retinal vein occlusion: The presenting sign of seronegative rheumatoid arthritis.

    PubMed

    Trese, Matthew G J; Yonekawa, Yoshihiro; Thomas, Benjamin J; Randhawa, Sandeep

    2016-07-01

    To report the case of a patient who presented with a vasculitic central retinal vein occlusion (CRVO), which was the result of an undiagnosed systemic inflammatory condition, seronegative rheumatoid arthritis (RA). The patient presented with reduced vision in the left eye and polyarthralgia. Fundoscopic examination revealed a central retinal vein occlusion (CRVO) with concurrent evidence of vasculitis. Work-up for polyarthralgia included comprehensive serologic testing for connective tissue disease, including Vectra ® disease activity (DA) testing. Results of these studies confirmed the diagnosis of seronegative rheumatoid arthritis (RA). Systemic steroid therapy was initiated with subsequent anatomic and visual improvement. We hypothesize that the systemic inflammation-a hallmark of RA-led to the development of a vasculitic CRVO and, thus, the retinal manifestations served as the disease marker that prompted thorough work-up of the patient's disease, even in the face of initial seronegativity. This case serves as a reminder that, in the setting of CRVO and polyarthralgia, systemic inflammatory conditions must be considered as the underlying etiology. Further, this case report highlights our evolving understanding of the role that serologic markers play in the diagnosis and monitoring of RA.

  19. Effects of tracheal occlusion with retinoic acid administration on normal lung development.

    PubMed

    Delabaere, Amélie; Marceau, Geoffroy; Coste, Karen; Blanchon, Loïc; Déchelotte, Pierre-Jean; Blanc, Pierre; Sapin, Vincent; Gallot, Denis

    2017-05-01

    Tracheal occlusion (TO) is an investigational therapy for severe congenital diaphragmatic hernia that decreases pulmonary hypoplasia, but sustained TO also induces deficient surfactant synthesis. Intramuscular maternal administration of retinoic acid (RA) in a surgical rabbit model of congenital diaphragmatic hernia showed a beneficial effect on lung maturation. We evaluated the potential of RA delivery into the trachea and studied the combined effects of TO and RA on normal lung development. Experiments were performed on normal rabbit fetuses. Liposomes and capric triglyceride (Miglyol ® ), alone and with RA, were administered in the trachea just before TO (d26). Lung morphology and surfactant production were studied at term (d30). Tracheal occlusion increased lung weight and enhanced alveolar development but increased apoptotic activity and decreased surfactant expression. Tracheal injection of RA improved surfactant production to levels of normal controls. We established the potential of liposome and Miglyol as RA vehicle for delivering this bioactive molecule in the fetal airways. Tracheal RA injection seems to oppose the effects of TO in fetuses with normal lungs. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  20. Standing with electrical stimulation and splinting is no better than standing alone for management of ankle plantarflexion contractures in people with traumatic brain injury: a randomised trial.

    PubMed

    Leung, Joan; Harvey, Lisa A; Moseley, Anne M; Whiteside, Bhavini; Simpson, Melissa; Stroud, Katarina

    2014-12-01

    Is a combination of standing, electrical stimulation and splinting more effective than standing alone for the management of ankle contractures after severe brain injury? A multi-centre randomised trial with concealed allocation, assessor blinding and intention-to-treat analysis. Thirty-six adults with severe traumatic brain injury and ankle plantarflexion contractures. All participants underwent a 6-week program. The experimental group received tilt table standing, electrical stimulation and ankle splinting. The control group received tilt table standing alone. The primary outcome was passive ankle dorsiflexion with a 12Nm torque. Secondary outcomes included: passive dorsiflexion with lower torques (3, 5, 7 and 9Nm); spasticity; the walking item of the Functional Independence Measure; walking speed; global perceived effect of treatment; and perceived treatment credibility. OUTCOME MEASURES were taken at baseline (Week 0), end of intervention (Week 6), and follow-up (Week 10). The mean between-group differences (95% CI) for passive ankle dorsiflexion at Week 6 and Week 10 were -3 degrees (-8 to 2) and -1 degrees (-6 to 4), respectively, in favour of the control group. There was a small mean reduction of 1 point in spasticity at Week 6 (95% CI 0.1 to 1.8) in favour of the experimental group, but this effect disappeared at Week 10. There were no differences for other secondary outcome measures except the physiotherapists' perceived treatment credibility. Tilt table standing with electrical stimulation and splinting is not better than tilt table standing alone for the management of ankle contractures after severe brain injury. ACTRN12608000637347. [Leung J, Harvey LA, Moseley AM, Whiteside B, Simpson M, Stroud K (2014) Standing with electrical stimulation and splinting is no better than standing alone for management of ankle plantarflexion contractures in people with traumatic brain injury: a randomised trial.Journal of Physiotherapy60: 201-208]. Copyright © 2014