Sample records for occlusions current devices

  1. Recanalization of Chronic Total Occlusion Lesions: A Critical Appraisal of Current Devices and Techniques

    PubMed Central

    2016-01-01

    Chronic Total Occlusion (CTO) has been considered as one of the “final frontier” in interventional cardiology. Until recently, the patients with CTO are often managed surgically or medically due to lack of published evidence of clinical benefits and lower success rate of percutaneous recanalization of CTO. However, the introduction of enhanced guidewires, microcatheters combined with novel specialized devices and techniques reduce the number of unapproachable CTO. In this review article, current techniques and devices of percutaneous recanalization of CTO have been systematically summarized, which may help budding interventional cardiologists to theoretically understand these complex procedures and to deliver safe and effective percutaneous management of CTO to the patients. PMID:27790503

  2. Development of reversible vas deferens occlusive device: IV. Rigid prosthetic devices.

    PubMed

    Drueschke, E E; Zaneveld, L J; Burns, M; Rodzen, R; Wingfield, J R; Maness, J H

    1975-01-01

    Different types of rigid, reversible, vas deferens occlusive devices were developed and evaluated in 14 unilaterally vasectomized dogs. All prosthetic devices had molded silicone rubber bodies, and rigid inflow and outflow tubes. Various techniques for the removal of the vas luminal epithelium, and for the preparation of porous ceramic and etched stainless steel surfaces to encourage tissue ingrowth into the prosthetic device end tubues were attempted. The devices differed in their methods of achieving occlusion. One device used a "rotary stem valve" which had a C-section rotating mechanism; the others used the "shuttle stem valve" which possessed an occlusive element that moved transverse to the axis of flow in the device, thus occluding the device when the stem was depressed. The rotarystem valve was implanted by means of a longitudinal incision. The remaining 13 shuttle stem devices were placed in the vas using either a longitudinal or a transverse implantation. Inno case was sperm transport through the prosthetic devices obtained for more than a few ejaculations.

  3. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  4. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  5. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  6. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  7. 21 CFR 884.5380 - Contraceptive tubal occlusion device (TOD) and introducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive tubal occlusion device (TOD) and... Gynecological Therapeutic Devices § 884.5380 Contraceptive tubal occlusion device (TOD) and introducer. (a) Identification. A contraceptive tubal occlusion device (TOD) and introducer is a device designed to close a...

  8. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    PubMed Central

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  9. A New Occlusion Device: Application of the ArtVentive Endoluminal Occlusion System (EOS)—First in Human Clinical Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venbrux, Anthony C., E-mail: avenbrux@mfa.gwu.edu; Rudakov, Leon, E-mail: leonrudakov@artventivemedical.com; Plass, Andre, E-mail: andre.plass@usz.ch

    2013-05-24

    PurposeThe purpose of this study was to determine the safety and efficacy of a new endoluminal occlusion device, ArtVentive endoluminal occlusion system (EOS), to occlude the spermatic vein in symptomatic males with varicoceles.MethodsThe ArtVentive EOS device has been developed for percutaneous, peripheral occlusion of the peripheral arterial and venous vasculature. The system is comprised of an implantable occlusion device and a delivery catheter. At present, there are two device sizes: (a) size 1 for target vessels ranging between 3.5 and 5.5 mm in diameter, and (b) size 2 for target vessels 5.5–8.5 mm in diameter. The treatment group included six adult males,more » ages 22–34 years. Nine target vessels were occluded. A total of 20 devices were implanted in six subjects.ResultsThe acute occlusion rate at the end of the procedure was 100 % occurring in nine of nine vessels. The spermatic veins of all patients remained occluded on venography at 30 days follow-up. Pain scores related to varicoceles decreased in five of six patients.ConclusionsAlthough we recognize this study is limited, initial experience indicates that the ArtVentive EOS is a safe and effective new device for occlusion of vessels (varicoceles). The device has potential applications in other clinical conditions requiring occlusion of veins or arteries.« less

  10. A Novel Nitinol Spherical Occlusion Device for Liver Cancer

    PubMed Central

    Hsiao, Hao-Ming; Wang, Yi-Ping; Ko, Chun-Yi; Cheng, Yu-Han; Lee, Han-Yu

    2016-01-01

    Liver cancer or hepatic cancer is a cancer that originates in the liver. It is formed from either the liver itself or from structures within the liver, including blood vessels or the bile duct. Liver cancer can be a life-threatening condition, but it may be cured if found early. Hepatic artery embolization is one of the treatment options involving the injection of substances to reduce the blood flow to cancer cells in the livers of patients with tumors that cannot be removed by surgery; however, this treatment has some limitations. In this paper, we propose a novel nitinol “spherical occlusion device” concept, the first of its kind in the world. Our proposed spherical occlusion device is able to reduce the blood flow to cancer cells by deploying it in the upstream hepatic artery supplying blood to the liver. Moreover, it could carry multiple chemotherapy or radioactive drugs for delivery directly to the target site. Nitinol alloy was chosen as the device material due to its excellent super-elastic property. Computational models were developed to predict the mechanical response of the device during manufacturing and deployment procedures, as well as its hemodynamic behavior. Simulation results showed that the presence of the spherical occlusion device with 14%–27% metal density deployed at the upstream location of the right hepatic artery had significant occlusion effects, with the average blood flow rate cut down by 30%–50%. A pulsed fiber laser and a series of expansions and heat treatments were developed to make the first prototype of the spherical occlusion device for the demonstration of our novel concept. PMID:28787820

  11. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    PubMed

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  12. Limitations of the Outback LTD re-entry device in femoropopliteal chronic total occlusions.

    PubMed

    Shin, Susanna H; Baril, Donald; Chaer, Rabih; Rhee, Robert; Makaroun, Michel; Marone, Luke

    2011-05-01

    interval, 0.05-1.02; P = .054). Although the Outback re-entry device can be successful in extending the applicability of endovascular management to difficult femoropopliteal occlusions, it is not uniformly successful in current clinical practice. Significant calcification at the proposed re-entry site is a strong predictor of failure. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  13. Current status of percutaneous coronary intervention of chronic total occlusion

    PubMed Central

    Ge, Jun-bo

    2012-01-01

    This paper describes the current status of percutaneous coronary intervention (PCI) for totally occluded coronary arteries. Chronic total occlusion is associated with 10%–20% of all PCI procedures. Results show that opening an occluded vessel, especially one supplying a considerable area of myocardium, may be beneficial for a patient’s angina relief and heart function. We describe the devices used currently in re-canalization such as new wires, microcatheters (including Tonus and Cosair) and intravascular ultrasound guidance. Different techniques to improve the success rate and reduce complications are discussed in detail. PMID:22843178

  14. Occlusion assessment of intracranial aneurysms treated with the WEB device.

    PubMed

    Caroff, Jildaz; Mihalea, Cristian; Tuilier, Titien; Barreau, Xavier; Cognard, Christophe; Desal, Hubert; Pierot, Laurent; Arnoux, Armelle; Moret, Jacques; Spelle, Laurent

    2016-09-01

    The Woven EndoBridge (WEB) system is an innovative device under evaluation for its capacity to treat wide-neck bifurcation intracranial aneurysms. The purpose of this study is to evaluate the use of the different occlusion scales available in clinical practice. Seven WEB-experienced neurointerventionalists were provided with 30 angiographic follow-up data sets and asked to grade each evaluation point according to the Bicêtre Occlusion Scale Score (BOSS), firstly based on DSA images only then using additional C-Arm VasoCT analysis. This BOSS evaluation was then converted into the WEB Occlusion Scale (WOS) and into a dichotomized scale (complete occlusion or not). To estimate the inter-rater agreement among the seven raters, an overall kappa coefficient [1] and its standard error (SE) were computed. Using the five-grade BOSS, raters showed "moderate" agreement (kappa = 0.56). Using the three-grade WOS, agreement appeared slightly better (kappa = 0.59). Strongest inter-rater agreement was observed with a dichotomized version of the scale (complete occlusion or not), which enabled an "almost perfect" agreement (kappa = 0.88). VasoCT consistently enhanced the agreement particularly with regards depicting intra-WEB residual filling. The WOS is a consistent means to angiographically evaluate the WEB device efficiency. But the five-grade BOSS scale allows to identify aneurysm subgroups with differing risks of recurrence and/or rehemorrhage, which needs to be separated especially at the initial phase of evaluation of this innovative device. The additional use of VasoCT allows better inter-rater agreement in evaluating occlusion and specially in depicting intra-WEB persistent filling.

  15. Guide wire extension for shape memory polymer occlusion removal devices

    DOEpatents

    Maitland, Duncan J [Pleasant Hill, CA; Small, IV, Ward; Hartman, Jonathan [Sacramento, CA

    2009-11-03

    A flexible extension for a shape memory polymer occlusion removal device. A shape memory polymer instrument is transported through a vessel via a catheter. A flexible elongated unit is operatively connected to the distal end of the shape memory polymer instrument to enhance maneuverability through tortuous paths en route to the occlusion.

  16. Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jambon, E.; Petitpierre, F.; Brizzi, V.

    PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomesmore » and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.« less

  17. Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model.

    PubMed

    Hodis, Simona; Ding, Yong-Hong; Dai, Daying; Lingineni, Ravi; Mut, Fernando; Cebral, Juan; Kallmes, David; Kadirvel, Ramanathan

    2016-01-01

    Implanted, actual flow diverter pore density is thought to be strongly influenced by proper matching between the device size and parent artery diameter. The objective of this study was to characterize the correlation between device sizing, metal coverage, and the resultant occlusion of aneurysms following flow diverter treatment in a rabbit model. Rabbit saccular aneurysms were treated with flow diverters (iso-sized to proximal parent artery, 0.5 mm oversized, or 1.0 mm oversized, respectively, n=6 for each group). Eight weeks after implantation, the angiographic degree of aneurysm occlusion was graded (complete, near-complete, or incomplete). The ostium of the explanted aneurysm covered with the flow diverter struts was photographed. Based on gross anatomic findings, the metal coverage and pore density at the ostium of the aneurysm were calculated and correlated with the degree of aneurysm occlusion. Angiographic results showed there were no statistically significant differences in aneurysm geometry and occlusion among groups. The mean parent artery diameter to flow diverter diameter ratio was higher in the 1.0 mm oversized group than in the other groups. Neither the percentage metal coverage nor the pore density showed statistically significant differences among groups. Aneurysm occlusion was inversely correlated with the ostium diameter, irrespective of the size of the device implanted. Device sizing alone does not predict resultant pore density or metal coverage following flow diverter implantation in the rabbit aneurysm model. Aneurysm occlusion was not impacted by either metal coverage or pore density, but was inversely correlated with the diameter of the ostium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Prosthetic occlusive device for an internal passageway

    NASA Technical Reports Server (NTRS)

    Tenney, J. B., Jr. (Inventor)

    1983-01-01

    An occlusive device is disclosed for surgical implant to occlude the lumen of an internal organ. The device includes a cuff having a backing collar and two isolated cuff chambers. The fluid pressure of one chamber is regulated by a pump/valve reservoir unit. The other chamber is unregulated in pressure but its fluid volume is adjusted by removing or adding fluid to a septum/reservoir by means of a hypodermic needle. Pressure changes are transmitted between the two cuff chambers via faying surfaces which are sufficiently large in contact area and thin as to transmit pressure generally without attenuation. By adjusting the fluid volume of the septum, the operating pressure of the device may be adjusted to accommodate tubular organs of different diameter sizes as well as to compensate for changes in the organ following implant without reoperation.

  19. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device.

    PubMed

    Philip, Ranjit; Waller, B Rush; Agrawal, Vijaykumar; Wright, Dena; Arevalo, Alejandro; Zurakowski, David; Sathanandam, Shyam

    2016-02-01

    The aim of this study was to describe and differentiate the morphology of patent ductus arteriosus (PDA) seen in children born prematurely from other PDA types. PDAs are currently classified as types A-E using the Krichenko's classification. Children born prematurely with a PDA morphology that did not fit this classification were described as Type F PDA. A review of 100 consecutive children who underwent transcatheter device closure of PDA was performed. The diameter and length (L) of the PDA and the device diameter (D) were indexed to the descending aorta (DA) diameter. Comparison of 26 Type F PDAs was performed against, 29 Type A, 7 Type C and 32 Type E PDAs. Children with Type F PDAs (median 27.5 weeks gestation) were younger during the device occlusion compared with types A, C, and E (median age: 6 vs. 32, 11, and 42 months; P = 0.002). Type F PDAs were longer and larger, requiring a relatively large device for occlusion than types A, C, and E (Mean L/DA: 1.88 vs. 0.9, 1.21, and 0.89, P ≤ 0.01 and Mean D/DA: 1.04 vs. 0.46, 0.87, and 0.34, P ≤0.01). The Amplatzer vascular plug-II (AVP-II) was preferred for occlusion of Type F PDAs (85%; P <0.001). Children born prematurely have relatively larger and longer PDAs. These "fetal type PDAs" are best classified separately. We propose to classify them as Type F PDAs to add to types A-E currently in use. The AVP-II was effective in occluding Type F PDAs. © 2015 Wiley Periodicals, Inc.

  20. Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis.

    PubMed

    Borges Radaelli, Manuel Tomás; Idogava, Henrique Takashi; Spazzin, Aloisio Oro; Noritomi, Pedro Yoshito; Boscato, Noéli

    2018-04-30

    An occlusal device is frequently recommended for patients with bruxism to protect implant-supported restorations and prevent marginal bone loss. Scientific evidence to support this treatment is lacking. The purpose of this 3-dimensional (3D) finite element study was to evaluate the influence of an acrylic resin occlusal device, implant length, and insertion depth on stress distribution with functional and parafunctional loadings. Computer-aided design software was used to construct 8 models. The models were composed of a mandibular bone section including the second premolar and first and second molars. Insertion depths (bone level and 2 mm subcrestal) were simulated at the first molar. Three natural antagonist maxillary teeth and the placement or not of an occlusal device were simulated. Functional (200-N axial and 10-N oblique) and parafunctional (1000-N axial and 25-N oblique) forces were applied. Finite element analysis (FEA) was used to determine the maximum principal stress for the cortical and trabecular bone and von Mises for implant and prosthetic abutment. Stress concentration was observed at the abutment-implant and the implant-bone interfaces. Occlusal device placement changed the pattern of stress distribution and reduced stress levels from parafunctional loading in all structures, except in the trabecular bone. Implants with subcrestal insertion depths had reduced stress at the implant-abutment interface and cortical bone around the implant abutment, while the stress increased in the bone in contact with the implant. Parafunctional loading increased the stress levels in all structures when compared with functional loading. An occlusal device resulted in the lowest stress levels at the abutment and implant and the most favorable stress distribution between the cortical and trabecular bone. Under parafunctional loading, an occlusal device was more effective in reducing stress distribution for longer implants inserted at bone level. Subcrestally, implant

  1. The Performance of ICDAS-II Using Low-Powered Magnification with Light-Emitting Diode Headlight and Alternating Current Impedance Spectroscopy Device for Detection of Occlusal Caries on Primary Molars.

    PubMed

    Ari, Timucin; Ari, Nilgun

    2013-01-01

    Early detection of occlusal caries in children is challenging for the dentists, because of the morphology of pit and fissures. The aim of this study was to compare in vitro the diagnostic performance of low-powered magnification with light-emitting diode headlight (LPMLED) using ICDAS-II criteria and AC Impedance Spectroscopy (ACIS) device, on occlusal surfaces of primary molars. The occlusal surfaces of 18 extracted primary molars were examined blindly by two examiners. The teeth were sectioned and examined under light microscopy using Downer's histological criteria as gold standard. Good to excellent inter- and intraexaminer reproducibility, higher sensitivity, specificity, and AUC values were achieved by LPMLED at D1 threshold. Also the relationship between histology and LPMLED was statistically significant. In conclusion visual aids have the potential to improve the performance of early caries detection and clinical diagnostics in children. Despite its potential, ACIS device should be considered as an adjunct method in detecting caries on primary teeth.

  2. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  3. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occlusive wound dressing. 878.4020 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing. (a) Identification. An occlusive wound dressing is a nonresorbable, sterile or non-sterile device...

  4. Enhanced, rapid occlusion of carotid and vertebral arteries using the AMPLATZER Vascular Plug II device: the Duke Cerebrovascular Center experience in 8 patients with 22 AMPLATZER Vascular Plug II devices.

    PubMed

    Mihlon, Frank; Agrawal, Abishek; Nimjee, Shahid M; Ferrell, Andrew; Zomorodi, Ali R; Smith, Tony P; Britz, Gavin W

    2015-01-01

    Therapeutic embolization of the common carotid artery (CCA), internal carotid artery (ICA), and vertebral artery (VA) is necessary in the treatment of a subset of chronic arteriovenous fistulas (AVFs), hemorrhages, highly vascularized neoplasms before resection, and giant aneurysms. There are currently no reports of the use of the AMPLATZER Vascular Plug II (AVP II) device to occlude the CCA, ICA, or VA. The objective of this article is to present the Duke Cerebrovascular Center experience using the AVP II device in neurointerventional applications. This case series is a retrospective review of all of the cases at Duke University Hospital in which an AVP II device was used in the CCA, ICA, or VA up to September 2012. The AVP II device was often used in conjunction with embolization coils or as multiple AVP II devices deployed in tandem. During 2010-2012, 8 cases meeting criteria were performed. These included 2 chronic VA to internal jugular AVFs, 1 hemorrhagic CCA to internal jugular AVF secondary to invasive head and neck squamous cell carcinoma, 1 ICA hemorrhage secondary to invasive head and neck squamous cell carcinoma, 1 ICA hemorrhage secondary to trauma, 1 ruptured ICA aneurysm, 1 giant petrous ICA aneurysm, and 1 case of cervical vertebral sarcoma requiring preoperative VA embolization. Successful occlusion of the target vessel was achieved in all 8 cases. There was 1 major complication that consisted of a watershed distribution cerebral infarct; however, this was related to emergent occlusion of the ICA in the setting of intracranial hemorrhage and was not a problem intrinsic to the AVP II device. The AVP II device is relatively large, self-expanding vascular occlusion device that safely allows enhanced, rapid take-down of the CCA, ICA, and VA with low risk of distal migration. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Vascular occlusion with a balloon-expandable stent occluder.

    PubMed

    Moss, J G; Laborde, J C; Clem, M C; Rivera, F J; Encarnacion, C E; Meyer, K B; Palmaz, J C

    1994-05-01

    To evaluate the effectiveness of a new vascular occlusion device. The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. This new occlusive device offers immediate vascular occlusion with excellent stability.

  6. First experiences with a new device for mechanical thrombectomy in acute basilar artery occlusion.

    PubMed

    Roth, C; Mielke, A; Siekmann, R; Ferbert, A

    2011-01-01

    The aim of this study was to evaluate our first results using a new device for mechanical thrombectomy in patients with acute basilar artery occlusion. Between May 2009 and September 2010 a new device for aspiration thrombectomy (The Penumbra System™; Penumbra Inc., Alameda, Calif., USA) was used in 12 patients with acute basilar artery occlusion. We performed a retrospective review of these patients' medical records. One patient received endovascular treatment without intravenous (IV) thrombolysis because of infarction on the initial CT scan. Eleven of 12 patients received IV thrombolysis with rtPA followed by endovascular thrombectomy according to a bridging concept. After thrombolysis, the basilar artery was patent in 1 patient (9%), partially recanalized in 3 (27%) and still occluded in 7 (64%). The endovascular device could not access in 2 patients (17%). Among the remaining 10 patients, the patency rate after thrombectomy was 100%. The overall patency rate after treatment was 9 of 12 (75%) at the time of discharge. National Institute of Health Stroke Scale improved from a median of 27 to a median of 18 after treatment. Four patients died (33%). The survivors had a mean modified Rankin Scale before discharge of 2.3 (range 0-4). A bridging therapy with the combination of IV thrombolysis with recombinant tissue plasminogen activator and continuous aspiration thrombectomy seems to be a promising therapy strategy for acute basilar artery occlusion. Furthermore, our results confirm the advantage of the additional use of this new thrombectomy device, working with thrombus aspiration, with a satisfactory patency rate and a good clinical outcome. Copyright © 2011 S. Karger AG, Basel.

  7. First-in-man experience with the ReVive PV peripheral thrombectomy device for the revascularization of below-the-knee embolic occlusions.

    PubMed

    Landau, David; Moomey, Charles; Fiorella, David

    2014-10-01

    To report the initial use of a novel thrombectomy device for revascularization of below-the-knee thromboembolic occlusions encountered during proximal revascularization procedures. The ReVive PV Peripheral Thrombectomy Device is a non-detachable, self-expanding stent-like device recently approved for peripheral thrombectomy. Four patients (3 women; mean age 68.8 years) undergoing proximal revascularization procedures experienced embolic occlusions of all 3 trifurcation vessels in 1 patient, the tibioperoneal trunk alone in 2 cases, and the peroneal artery alone in the last patient. In all cases, the involved arteries represented the primary or sole vessel(s) providing outflow to the lower extremity. In each case, the ReVive PV device was used to successfully extract the thrombus and restore flow to the distal extremity. No complications were encountered during any of the procedures. The ReVive PV peripheral thrombectomy device may facilitate the safe and efficient revascularization of distal arterial embolic occlusions.

  8. The BridgePoint devices to facilitate recanalization of chronic total coronary occlusions through controlled subintimal reentry.

    PubMed

    Werner, Gerald S

    2011-01-01

    In view of the improved long-term patency with drug-eluting stents, the challenge with chronic total coronary occlusion remains a low primary success rate. Modes of failure to open a chronic total coronary occlusion are mainly related to the inability to pass a wire through the proximal occlusion cap, and the most difficult part of the procedure is to guide the wire into the distal true lumen. A frequent situation is a subintimal wire position. The BridgePoint (BridgePoint Medical, MN, USA) family of devices is designed to cope with both of these problems. First, the CrossBoss™ catheter aims at passing through the proximal cap by manual rotation of a blunt proximal tip, and second, in case of a subintimal position, the Stingray™ balloon enables guided reentry from the subintimal space into the true lumen. Certain features of an occlusion might favor the CrossBoss device, while the reentry approach may also be used as a standalone bailout method. The aim is to provide a means to resolve otherwise failed attempts and to make it unnecessary to resort to the more complex and time-consuming retrograde wire techniques through collateral channels with the associated potential higher procedural risks.

  9. Rationale of cerebral protection devices in left atrial appendage occlusion.

    PubMed

    Meincke, Felix; Spangenberg, Tobias; Kreidel, Felix; Frerker, Christian; Virmani, Renu; Ladich, Elena; Kuck, Karl-Heinz; Ghanem, Alexander

    2017-01-01

    Aims of this case-series were to assess the feasibility of cerebral protection devices in interventional left atrial appendage occlusion (iLAAO) procedures and to yield insight into the pathomorphological correlate of early, procedural cerebral embolization during iLAAO. Five consecutive patients underwent iLLO flanked by the Sentinel CPS® (Claret Medical, Inc., Santa Rosa, CA) cerebral protection system. Placement and recapture of the Sentinel ® device as well as the iLAAO were successful and safe in all cases. Histomorphometric analysis of the collected filters showed embolized debris in all patients. Acute thrombus was found in three patients, organizing thrombus in four. Interestingly, two patients had endocardial or myocardial tissue in their filters. Cerebral protection during iLAAO with the Sentinel CPS ® device is feasible. Furthermore, this dataset identifies the formation and embolization of thrombus and cardiac tissue as emboligeneic sources and potential future targets to reduce procedural complications. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vessel occlusion transducer. 870.2890 Section 870.2890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion...

  11. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel occlusion transducer. 870.2890 Section 870.2890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2890 Vessel occlusion...

  12. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  13. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  14. 21 CFR 878.4020 - Occlusive wound dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occlusive wound dressing. 878.4020 Section 878.4020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4020 Occlusive wound dressing...

  15. Evaluation of the need for chest X-rays in the management of asymptomatic, intraluminal vascular access device occlusion in childhood cancer.

    PubMed

    Stammers, David; Connolly, Bairbre; Brandão, Leonardo R; Zupanec, Sue; Gupta, Sumit

    2017-07-01

    Venous access device (VAD) occlusion from intraluminal thrombus is a common complication during childhood cancer treatment. Current practice at many institutions is to assess VAD position with a chest X-ray (CXR) prior to intraluminal administration of tissue plasminogen activator (tPA). We aimed to determine the utility of this practice. A retrospective chart review of children with newly diagnosed cancer with a VAD, treated at The Hospital for Sick Children between 2010 and 2011, was performed. Episodes of line occlusion were identified both by reviewing patient CXRs for indication and identifying tPA doses dispensed. These episodes were reviewed to determine whether CXR findings resulted in management other than tPA. Cases in which the X-ray resulted in a change in management were further reviewed to determine whether administration of tPA could have resulted in potential patient harm. A total of 330 patients with newly diagnosed cancer with VADs were identified. Eighty-five (25.8%) patients experienced 123 episodes of VAD occlusion. VAD occlusions occurred more frequently in patients with tunneled external central venous lines (16/39, 41.5%) and peripherally inserted central catheters (PICC) (27/73, 37.0%) versus PORT (42/216, 19.4%; P = 0.001). There were nine (8.1%) episodes of VAD occlusion evaluated with a CXR in which the findings led to a change in management other than administering tPA. In each case, multiple specialists independently concluded that administration of tPA would have been unlikely to cause patient harm. Routine CXRs prior to the administration of tPA for asymptomatic VAD occlusion can safely be omitted. © 2016 Wiley Periodicals, Inc.

  16. Management of post midface distraction occlusal discrepancy using temporary anchorage devices in a cleft patient

    PubMed Central

    Koteswara Prasad, N. K.; Hussain, Syed Altaf; Chitharanjan, Arun B.; Murthy, Jyotsna

    2015-01-01

    Open bite deformity following a successful midface advancement by distraction osteogenesis is a common complication. Temporary anchorage devices can be deployed during the distraction and post-distraction settling phases for restoring the occlusion even in severe cases. The following report describes the management of severe anterior open bite following maxillary distraction. PMID:25991895

  17. There's an app for that: A handheld smartphone-based infrared imaging device to assess adequacy and level of aortic occlusion during REBOA.

    PubMed

    Sokol, Kyle K; Black, George E; Willey, Sandra B; Kniery, Kevin; Marko, Shannon T; Eckert, Matthew J; Martin, Matthew J

    2017-01-01

    Advances in thermal imaging devices have made them an appealing noninvasive point-of-care imaging adjunct in the trauma setting. We sought to assess whether a smartphone-based infrared imaging device (SBIR) could determine presence and location of aortic occlusion in a swine model. We hypothesized that various levels of aortic occlusion would transmit significantly different heat signatures at various anatomical points. Six swine (35-50 kg) underwent sequential zone 1 (Z1) aortic cross clamping as well as zone 3 (Z3) aortic balloon occlusion (resuscitative endovascular balloon occlusion of the aorta [REBOA]). SBIR images and readings (FLIR One) were taken at five anatomic points (axilla [A], subcostal [S], umbilical [U], inguinal [I], medial malleolar [M]) and were used to determine significant thermal trends 5 minutes to 10 minutes after Z1 and Z3 occlusion. Significant (p ≤ 0.05) thermal ratio patterns were identified and compared among groups, and images were reviewed for obvious qualitative differences at the various levels of occlusion. Body temperatures were similar during control (CON), Z1 occlusion, and Z3 occlusion, ranging from 94.0 °F to 100.9 °F (p = 0.126). No significant temperature differences were found among A, S, U, I, M points prior to and after aortic occlusions. Among the anatomical 2-point ratios evaluated, A/M and S/M ratios were the best predictors of aortic occlusion, whether at Z1 (8.2 °F, p < 0.01; 10.9 °F, p < 0.01) or Z3 (7.3 °F, p < 0.01; 8.4 °F, p < 0.01), respectively. The best predictor of Z1 versus Z3 level of occlusion was the S/I ratio (5.2 °F, p < 0.05 vs. 3.4 °F, p = 0.27). SBIR generated qualitatively different thermal signatures among groups. SBIR was capable of detecting thermal trends during Z1 and Z3 aortic occlusion by using an anatomical 2-point thermal ratio. There were also easily recognized qualitative differences between control and occlusion images that would allow immediate determination of adequate

  18. Initial experience with a dedicated coronary re-entry device for revascularization of chronic total occlusions.

    PubMed

    Whitlow, Patrick L; Lombardi, William L; Araya, Mario; Michael Wyman, R; Torres, Humberto; Dauvergne, Christian; Tsuchikane, Etsuo; Lansky, Alexandra; Thompson, Craig A

    2012-11-01

    The aim of this registry was to evaluate a new device designed to facilitate antegrade guidewire re-entry into the true lumen of a chronic total coronary occlusion (CTO) from the adjacent subintimal space. Successful recanalization of CTOs results in clinical improvement in appropriately selected patients. CTO intervention is time- and resource-consuming, and a simplified approach enabling antegrade guidewire re-entry into the distal true lumen might improve success. Patients with CTO and ischemia were entered into a prospective registry regardless of lesion characteristics. If wire manipulation resulted in subintimal wire entrapment, a new re-entry tool (a 2.5-mm flat subintimal balloon with two exit ports offset by 180°) was used as a platform to attempt guidewire penetration into the distal true lumen. The primary endpoint assessed was successful device-guided re-entry. Standard techniques were then utilized to open the CTO. In 40 consecutive CTO lesions attempted, 19 resulted in subintimal wire entrapment (mean occlusion length 44 mm). Sixteen of these 19 were successfully crossed with an antegrade guidewire into the distal true lumen using the new device (84%). One patient with unsuccessful re-entry was subsequently recanalized with a retrograde technique. All crossed lesions were stented (17/17), resulting in TIMI 3 flow without major complications. Two cases were unsuccessful. One patient had a grade I coronary perforation requiring no treatment. A new device to recanalize CTOs complicated by subintimal wire entrapment can be used successfully by experienced operators. Further study of this coronary re-entry device is ongoing. Copyright © 2011 Wiley Periodicals, Inc.

  19. Retinal vein occlusion: current treatment.

    PubMed

    Lattanzio, Rosangela; Torres Gimeno, Ana; Battaglia Parodi, Maurizio; Bandello, Francesco

    2011-01-01

    Retinal vein occlusion (RVO) is a pathology noted for more than 150 years. Although a lot has been written on the matter, it is still a frequent condition with multifactorial etiopathogenesis with many unclear aspects. The RVO pathogenesis has varied systemic and local implications that make it difficult to elaborate treatment guidelines. The management of the patient with RVO is very complex and a multidisciplinary approach is required in order to identify and correct the associated risk factors. Laser therapy remains the gold standard in RVO, but only modest functional improvement has been shown in branch retinal occlusion forms. Multicenter studies of intravitreal drugs present them as an option to combine with laser. Anti-vascular endothelial growth factor, corticosteroids and sustained-release implants are the future weapons to stop disease progression and get a better visual outcome. Consequently, it is useful to clarify some aspects of the pathology that allow a better patient management. Copyright © 2010 S. Karger AG, Basel.

  20. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

    PubMed Central

    Sukotjo, Cortino

    2013-01-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387

  1. Preclinical assessment of a modified Occlutech left atrial appendage closure device in a canine model.

    PubMed

    Kim, Jung-Sun; Lee, Seul-Gee; Bong, Sung-Kyung; Park, Se-Il; Hong, Sung-Yu; Shin, Sanghoon; Shim, Chi Young; Hong, Geu-Ru; Choi, Donghoon; Jang, Yangsoo; Park, Jai-Wun

    2016-10-15

    LAA occlusion has a similar stroke prevention efficacy compared to anticoagulation treatment for non-valvular atrial fibrillation. The objective of this study was to assess the feasibility and safety of a modified Occlutech® left atrial appendage (LAA) closure device in a canine model. The device was implanted in 10 dogs (33±1kg) using fluoroscopy and transesophageal echocardiography (TEE) guidance. The modified Occlutech® LAA occlusion device was compared with the current version, the Watchman device, and the Amplazter cardiac plug (ACP). LAA occlusion and anchoring to the LAA were evaluated. All dogs were assessed using angiography, TEE, and a gross anatomy examination. The 10 LAA occlusion devices were to be implanted into 10 dogs (5 modified Occlutech devices, 3 current version of Occlutech devices, 1 Watchman, and 1 ACP). LAA implantation was not performed in one dog due to transeptal puncture failure. The three current version of Occlutech devices were embolized immediately after implantation, so three modified devices of the same size were implanted securely without embolization. The mean implant size was 20.1±2.0mm. The devices chosen were a mean of 23.3±10.6% larger than the measured landing zone diameters. Post-implant angiography and TEE revealed well-positioned devices without pericardial effusion or impingement on surrounding structures. The results of this acute animal study suggested that a modified Occlutech® LAA occlusion device was feasible and had greater anchoring performance in canines. Additional large clinical studies are needed to evaluate safety and efficacy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Successful revascularization of chronic total occlusion of lower extremity arteries: a wire only and bail out use of re-entry device approach.

    PubMed

    Langhoff, R; Stumpe, S; Treitl, M; Schulte, K L

    2013-10-01

    The management of progressive peripheral artery disease experienced a vast change in paradigms over the last decades for the benefit of minimal invasive therapy as a first-line strategy. With the constant development of new devices, materials and dedicated access strategies, more complex lesions can be managed but the limitations to successfully treat chronic total occlusions are still the challenge to re-enter the true lumen. The aim of this retrospective study was to investigate, if a "wire only" strategy leads to an acceptable success rate in a mixed cohort of CTO lesions and to what extend re-entry devices are used. We retrospectively analyzed patients treated at the Vascular Center Berlin between 2011 and 2013 with chronic total occlusion out of a prospective conducted database (Endovascular MILestones - EMIL) for demographics, risk factors, co-morbidities, technical success rates, lesion characteristics and use of guidewires as well as re-entry systems. A total of 128 patients with 146 lesions, which represent a subgroup of all the cases performed in our center, following a predefined treatment algorithm for chronic total occlusions (CTOs), have been analyzed. We achieved a technical success in 133 (91.1%) of all cases following a "wire only" strategy. Out of 13 (8.9%) CTOs with technical failure in 7 (53.9%) CTOs a re-entry device (Off-Road®) with a 100% technical success has been used. In 91.1% of chronic total occlusion lesions the use of 2 wires only (88.7%) led to a successful recanalization. A "wire only" strategy followed by the use of a re-entry device as a bail out strategy, led to a total of 140 (96%) lesions to be successfully recanalized. In more than 90% of all cases with chronic total occlusion of peripheral lower extremity arteries, endovascular intervention has been successful following a "wire only" strategy. When deciding to use a re-entry device, in case of a failure of a proper wire re-entry at the reconstitution point, a technical

  3. A possible association of idiopathic osteosclerosis with excessive occlusal forces.

    PubMed

    Misirlioglu, Melda; Nalcaci, Rana; Baran, Ilgi; Adisen, Mehmet Zahit; Yilmaz, Selmi

    2014-03-01

    The aim of the study was to determine the relationship between idiopathic osteosclerotic lesions and occlusal forces using the T-Scan II computerized occlusal analysis device, and to test the sensitivity of the system in occlusal analysis. The study was conducted with 21 volunteers with idiopathic osteosclerosis (IO; 14 women, 7 men) aged between 17 and 62 years (mean 29.95). For every patient, seven or eight recordings were made with the T-Scan II occlusal analysis device in maximum intercuspation, and the last two (excluding any with technical problems) were chosen for evaluation. For each lesion-related area, the distribution of high occlusal forces from two different movies was analyzed. In 18 patients (85.71%), lesions were observed in an area of high occlusal force, and in 13 patients (61.9%), the lesions were located at the first area subjected to high occlusal forces. The percentage distribution of high forces at a lesion related area ranged from 0% to 88%. On average, the high forces at an osteosclerotic lesion area accounted for 20% of the maximum total force. No statistical differences were observed between the measurements of the two selected recordings (P > .05). The findings of this study suggest a possible relationship between IO and occlusal forces and primary contacts. T-Scan II was found to be a successful diagnostic device for detecting primary contacts and excessive occlusal forces.

  4. Evolution of atherectomy devices.

    PubMed

    Al Khoury, G; Chaer, R

    2011-08-01

    Percutaneous atherectomy provides an alternative approach to the endovascular treatment of peripheral atherosclerotic occlusive disease beyond angioplasty and stenting, and has the theoretical advantage of lesion debulking and minimizing barotrauma to the vessel wall. Atherectomy has evolved greatly during the last decade, with currently four FDA approved devices for the treatment of peripheral arterial disease. Several reports have focused on the initial technical success rates, and demonstrated the safety and short as well as mid-term efficacy of atherectomy devices. This article will review the evolution of current atherectomy devices and the associated literature.

  5. Microfluidics for investigating vaso-occlusions in sickle cell disease.

    PubMed

    Horton, Renita E

    2017-07-01

    SCD stems from amutation in the beta globin gene. Upon deoxygenation, hemoglobin polymerizes and triggers RBC remodeling. This phenomenon is central to SCD pathogenesis as individuals suffering from the disease are plagued by painful vaso-occlusive crises episodes. These episodes are the result of a combination of processes including inflammation, thrombosis, and blood cell adhesion to the vascular wall which leads to blockages within the vasculature termed vaso-occlusions. Vaso-occlusive episodes deprive tissues of oxygen and are a major contributor to SCD-related complications; unfortunately, the complex mechanisms that contribute to vaso-occlusions are not well understood. Vaso-occlusions can occur in post-capillary venules; hence, the microvasculature is a prime target for SCD therapies. Traditional in vitro systems poorly recapitulate architectural and dynamic flow properties of in vivo systems. However, microfluidic devices can capture features of the native vasculature such as cellular composition, flow, geometry, and ECM presentation. This review, although not comprehensive, highlights microfluidic approaches that aim to improve our current understanding of the pathophysiological mechanisms surrounding SCD. Microfluidic platforms can aid in identifying factors that may contribute to disease severity and can serve as suitable test beds for novel treatment strategies which may improve patient outcomes. © 2017 John Wiley & Sons Ltd.

  6. Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus.

    PubMed

    Zulqarnain, Arif; Younas, Muhammad; Waqar, Tariq; Beg, Ahsan; Asma, Touseef; Baig, Mirza Ahmad Raza

    2016-01-01

    Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.

  7. Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus

    PubMed Central

    Zulqarnain, Arif; Younas, Muhammad; Waqar, Tariq; Beg, Ahsan; Asma, Touseef; Baig, Mirza Ahmad Raza

    2016-01-01

    Objectives: Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. Methods: This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. Results: There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. Conclusion: The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation. PMID:27648051

  8. Current understanding of chronic total occlusion of the internal carotid artery

    PubMed Central

    Xu, Baofeng; Li, Chao; Guo, Yunbao; Xu, Kan; Yang, Yi; Yu, Jinlu

    2018-01-01

    At present, there is limited understanding of chronic total occlusion (CTO) of the internal carotid artery (ICA). Therefore, the present report collected related cases from PubMed and reviewed the literature. Cerebral vessels may form collateral circulation immediately or gradually following CTO of the ICA. The natural history of CTO of the ICA includes a variety of outcomes, all of which are biased toward a non-benign progressive process and are characterized by insufficient cerebral perfusion, embolus detachment and cognitive dysfunction. The majority of cases of CTO of the ICA require treatment. In early studies, the results of external-ICA bypass were unsatisfactory, while recanalization is now considered the only viable option. The current treatment indications mainly depend on the degree of injury to the cerebrovascular reserve and the extent to which the oxygen extraction fraction is increased. The length, height and duration of ICA occlusion are also relevant, though more frequently, the condition depends on multiple factors. Endovascular interventional recanalization, carotid endarterectomy (CEA) and hybrid surgery may be conducted in a select group of patients. As novel materials are developed, the success rate of simple recanalization may gradually increase; however, hybrid surgery may be more representative of the current trend, as advanced CEA can remove carotid atherosclerosis plaques, thus reducing the technological demands of the subsequent interventional recanalization. There are many complications that may result from recanalization following CTO of the ICA, including hyperperfusion and technical errors; therefore, the operation must be conducted carefully. If the recanalization is successful, it typically results in a stable improvement of patient condition in the long term. However, despite these conclusions, more studies are required in the future to further improve current understanding of CTO of the ICA. PMID:29435269

  9. Simultaneous Antegrade-Retrograde Subintimal Revascularization of a Femoropopliteal Chronic Total Occlusion by a Reentry Device-Facilitated Puncture of a Retrogradely Inserted Balloon.

    PubMed

    Goltz, Jan Peter; Anton, Susanne; Wiedner, Marcus; Barkhausen, Jörg; Stahlberg, Erik

    2017-08-01

    To report a rendezvous technique for subintimal revascularization of a chronic total occlusion (CTO) of the superficial femoral artery (SFA). This maneuver is appropriate after failure to cross a long SFA CTO via intra- and subintimal approaches from the ipsilateral femoral as well as retrograde posterior tibial artery (PTA) access sites. After predilation of the subintimal space from the femoral access, a reentry device was placed at the level of the first popliteal artery segment. A balloon was delivered via the retrograde PTA access and inflated at the corresponding level of the reentry device. The balloon was punctured with the needle of the reentry device under fluoroscopic control, and a 0.014-inch guidewire was placed within the punctured balloon. The balloon and the antegrade guidewire were retracted from the retrograde access while the guidewire was gently pushed from the femoral site. Conventional balloon angioplasty of the SFA occlusion was performed via the femoral access, followed by overlapping stent-graft implantation. Complete revascularization of the CTO was documented. In selected cases a transfemoral reentry device-assisted puncture of a retrogradely inserted balloon within the subintimal space may facilitate a rendezvous and revascularization if standard techniques to cross long CTOs have failed.

  10. Current devices of respiratory physiotherapy

    PubMed Central

    Hristara-Papadopoulou, A; Tsanakas, J; Diomou, G; Papadopoulou, O

    2008-01-01

    In recent years patients with respiratory diseases use various devices, which help the removal of mucus from the airways and the improvement of pulmonary function. The aim of the present study is to determine the effectiveness of the current devices of respiratory physiotherapy, as it comes from the review of literature. The current devices of physiotherapy for patients with respiratory diseases, are presented as an alternative therapy method or a supplemental therapy and they can motivate patients to apply therapy by themselves. These devices seem to increase patients' compliance to daily treatment, because they present many benefits, as independent application, full control of therapy and easy use. These devices are the Positive Expiratory Pressure, the High Frequency Chest Wall Oscillation, the Oral High Frequency Oscillation, the Intrapulmonary Percussive Ventilation, the Incentive Spirometry the Flutter and the Acapella and the Cornet. Current devices seem to be effective in terms of mucus expectoration and pulmonary function improvement, as it is shown by published studies. The choice of the suitable device for each patient is a challenge for the physiotherapist in order to achieve better compliance in daily treatment. More controlled studies are needed due to the fact that the number of published studies is limited. PMID:19158964

  11. Systematic Assessment of the Various Controversies, Difficulties, and Current Trends in the Reestablishment of Lost Occlusal Planes in Edentulous Patients

    PubMed Central

    Sahoo, S; Singh, D; Raghav, D; Singh, G; Sarin, A; Kumar, P

    2014-01-01

    Accurate occlusal plane orientation is an essential factor in the fabrication of complete denture prosthesis. Over the years, it has received a number of methodologies by several researchers utilizing various anatomical landmarks however none of them is considered as perfect that could orient ideal occlusal plane. The presented literature review is an attempt to enlighten historical perspectives, pioneer researches, different controversies, difficulties and current trends for re-establishment of lost occlusal plane in edentulous patients. An extensive literature search was performed using Medline/PubMed interface and other scholarly research bibliographic databases using Medical Subject Headings. Studies describing research studies, case series and assorted clinical reports were retrieved and evaluated from 1963 to 2013. Most of the studies have suggest and evidence to consider Camper's plane for artificial orientation of occlusal plane however there is a substantial lack of genuine long term studies and authentic data that could recommend a single reliable landmark for perfect occlusal plane reorientation in a variety of cases. PMID:24971200

  12. Systematic assessment of the various controversies, difficulties, and current trends in the reestablishment of lost occlusal planes in edentulous patients.

    PubMed

    Sahoo, S; Singh, D; Raghav, D; Singh, G; Sarin, A; Kumar, P

    2014-05-01

    Accurate occlusal plane orientation is an essential factor in the fabrication of complete denture prosthesis. Over the years, it has received a number of methodologies by several researchers utilizing various anatomical landmarks however none of them is considered as perfect that could orient ideal occlusal plane. The presented literature review is an attempt to enlighten historical perspectives, pioneer researches, different controversies, difficulties and current trends for re-establishment of lost occlusal plane in edentulous patients. An extensive literature search was performed using Medline/PubMed interface and other scholarly research bibliographic databases using Medical Subject Headings. Studies describing research studies, case series and assorted clinical reports were retrieved and evaluated from 1963 to 2013. Most of the studies have suggest and evidence to consider Camper's plane for artificial orientation of occlusal plane however there is a substantial lack of genuine long term studies and authentic data that could recommend a single reliable landmark for perfect occlusal plane reorientation in a variety of cases.

  13. Reducing leakage current in semiconductor devices

    DOEpatents

    Lu, Bin; Matioli, Elison de Nazareth; Palacios, Tomas Apostol

    2018-03-06

    A semiconductor device includes a first region having a first semiconductor material and a second region having a second semiconductor material. The second region is formed over the first region. The semiconductor device also includes a current blocking structure formed in the first region between first and second terminals of the semiconductor device. The current blocking structure is configured to reduce current flow in the first region between the first and second terminals.

  14. Dental occlusion, body posture and temporomandibular disorders: where we are now and where we are heading for.

    PubMed

    Manfredini, D; Castroflorio, T; Perinetti, G; Guarda-Nardini, L

    2012-06-01

    The aim of this investigation was to perform a review of the literature dealing with the issue of relationships between dental occlusion, body posture and temporomandibular disorders (TMD). A search of the available literature was performed to determine what the current evidence is regarding: (i) The physiology of the dental occlusion-body posture relationship, (ii) The relationship of these two topics with TMD and (iii) The validity of the available clinical and instrumental devices (surface electromyography, kinesiography and postural platforms) to measure the dental occlusion-body posture-TMD relationship. The available posturographic techniques and devices have not consistently found any association between body posture and dental occlusion. This outcome is most likely due to the many compensation mechanisms occurring within the neuromuscular system regulating body balance. Furthermore, the literature shows that TMD are not often related to specific occlusal conditions, and they also do not have any detectable relationships with head and body posture. The use of clinical and instrumental approaches for assessing body posture is not supported by the wide majority of the literature, mainly because of wide variations in the measurable variables of posture. In conclusion, there is no evidence for the existence of a predictable relationship between occlusal and postural features, and it is clear that the presence of TMD pain is not related with the existence of measurable occluso-postural abnormalities. Therefore, the use instruments and techniques aiming to measure purported occlusal, electromyographic, kinesiographic or posturographic abnormalities cannot be justified in the evidence-based TMD practice. © 2012 Blackwell Publishing Ltd.

  15. Electromagnetic pulse-induced current measurement device

    NASA Astrophysics Data System (ADS)

    Gandhi, Om P.; Chen, Jin Y.

    1991-08-01

    To develop safety guidelines for exposure to high fields associated with an electromagnetic pulse (EMP), it is necessary to devise techniques that would measure the peak current induced in the human body. The main focus of this project was to design, fabricate, and test a portable, self-contained stand-on device that would measure and hold the peak current and the integrated change Q. The design specifications of the EMP-Induced Current Measurement Device are as follows: rise time of the current pulse, 5 ns; peak current, 20-600 A; charge Q, 0-20 microcoulombs. The device uses a stand-on parallel-plate bilayer sensor and fast high-frequency circuit that are well-shielded against spurious responses to high incident fields. Since the polarity of the incident peak electric field of the EMP may be either positive or negative, the induced peak current can also be positive or negative. Therefore, the device is designed to respond to either of these polarities and measure and hold both the peak current and the integrated charge which are simultaneously displayed on two separate 3-1/2 digit displays. The prototype device has been preliminarily tested with the EMP's generated at the Air Force Weapons Laboratory (ALECS facility) at Kirtland AFB, New Mexico.

  16. Amplatzer vascular plug for arteriovenous hemodialysis access occlusion: initial experience.

    PubMed

    Bui, J T; Gaba, R C; Knuttinen, M G; West, D L; Owens, C A

    2009-01-01

    The Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN) is a recently developed self-expanding metallic device indicated for peripheral vascular embolizations. Herein, we describe use of this device in the treatment of vascular complications related to arteriovenous hemodialysis fistulas and grafts. This HIPAA compliant retrospective study was approved by the institutional review board with informed consent waived. Six patients with problematic arteriovenous access underwent access occlusion using the AVP. Procedure indications included vascular steal syndrome in five patients, and enlarging vascular aneurysms in one patient. Contraindications for surgical correction were determined by the referring surgeon. AVP embolizations were performed using devices oversized by 50% introduced through vascular sheaths positioned within vein segments just beyond the arteriovenous anastomoses. Noninvasive evaluation of the involved extremity was performed pre- and post-embolization in addition to clinical follow-up examinations. Measured outcomes included success of angiographic occlusion, improvement in distal arterial flow, AVP number, AVP diameter, time to access occlusion, and clinical symptomatic improvement. Technical success was 100%, with complete arteriovenous access occlusion accomplished in all cases, with an average of 1.5 AVPs used per patient. Mean time to access occlusion was 19.3 minutes. Angiographic improvement in distal arterial flow was immediately evident and resolution of clinical symptoms occurred in all patients, with mean long-term follow-up of 16 months. No procedure-related complications were encountered. The Amplatzer Vascular Plug provides a minimally invasive and efficacious method for embolization of problematic arteriovenous hemodialysis access.

  17. Incidence, Characteristics, and Clinical Course of Device-Related Thrombus After Watchman Left Atrial Appendage Occlusion Device Implantation in Atrial Fibrillation Patients.

    PubMed

    Kubo, Shunsuke; Mizutani, Yukiko; Meemook, Krissada; Nakajima, Yoshifumi; Hussaini, Asma; Kar, Saibal

    2017-12-11

    This study investigated characteristics and clinical impact of device-related thrombus formation after Watchman device implantation in atrial fibrillation (AF) patients. Left atrial appendage occlusion using the Watchman device is an effective alternative to anticoagulation for stroke prevention in AF patients. However, device-related thrombus formation remains an important concern after Watchman implantation. From 2006 to 2014, 119 consecutive AF patients underwent Watchman implantation. Transesophageal echocardiographic (TEE) follow-up was scheduled at 45 days, at 6 months, and at 12 months after the procedure. The incidence, characteristics, and clinical course of device-related thrombus formation detected by TEE were assessed. Follow-up TEE identified thrombus formation on the Watchman device in 4 patients (3.4%). The prevalence of chronic AF was 100% in patients with thrombus, which was higher than that for patients without thrombus (40.0%). Deployed device size was numerically larger in patients with thrombus (29.3 ± 3.8 mm vs. 25.7 ± 3.2 mm, respectively). All patients with thrombus discontinued any of the anticoagulant/antiplatelet therapy which was required under the study protocol. After restarting or continuing warfarin and aspirin therapy, complete resolution of the thrombus was achieved in all patients at subsequent follow-up TEE. Warfarin therapy was discontinued within 6 months for all cases, and there was no thrombus recurrence. The mean follow-up duration was 1,456 ± 546 days, with no death, stroke, or systemic embolization events in patients with thrombus. AF burden, device size, and anticoagulant/antiplatelet regimens can be associated with device-related thrombus after Watchman device implantation. Short-term warfarin therapy was effective, and the clinical outcomes were favorable. Copyright © 2017 American College of Cardiology Foundation. All rights reserved.

  18. [Occlusion: current situation and prospect in view of holistic integrative medicine].

    PubMed

    Wang, M Q; Liu, X D

    2017-08-09

    The rise of holistic integrative medicine (HIM) is an inevitable consequence of modern medical development which emphasizes the change from specialization to integration of the most advanced medical knowledge. It does not mean a simple collection of the medical theories, but means the digestion of those theories for the clinical practical application. Because occlusal therapy is characterized as not only a high level of individualization, but also a relation to many stomatology and other disciplines, such as plastic surgery, orthopedics, neurosciences and psychology. It needs the HIM to guide the clinical practice. With undertaking occlusal therapy, to avoid the limitation due to the excessive specialized disciplines, and to provide effective treatment plans for abnormal occlusion induced diseases, it is necessary to develop the discipline of the holistic integrative stomatology.

  19. Long-term outcomes after re-entry device use for recanalization of common iliac artery chronic total occlusions.

    PubMed

    Kokkinidis, Damianos G; Alvandi, Bejan; Cotter, Ryan; Hossain, Prio; Foley, T Raymond; Singh, Gagan D; Waldo, Stephen W; Laird, John R; Armstrong, Ehrin J

    2018-03-09

    To examine the impact of re-entry device (RED) use on 1- and 5-year outcomes after endovascular treatment of common iliac artery (CIA) chronic total Occlusions (CTOs). There are not enough data regarding the long-term safety and efficacy of RED. We performed a two-center retrospective study of 115 patients (140 lesions) undergoing CIA CTO endovascular intervention between 2006 and 2016. Baseline characteristics and long-term outcomes were described. A Cox proportional hazard model was developed to determine if REDs were associated with target lesion revascularization (TLR) or major adverse limb events (MALE) after 1 and 5 years. Among 140 lesions, 43 (31%) required use of a RED. The mean age was 63.9 years and the majority (n = 80) of patients were male. An antegrade crossing approach and treatment of restenotic lesions were less common in the RED group (10% vs. 29%, P < .05 and 0% vs. 21%, P < .05, respectively). There were no significant differences in Rutherford class, pre-procedure ABI, or patient presentation. The procedural complication rates were similar between the two groups. The 1- and 5-year TLR rates for lesions treated with re-entry device vs. standard approaches were 11% vs. 9%; P = 0.8 and 29% vs. 29%; P = 0.9 respectively. The 1 and 5-year MALE rates for lesions treated with re-entry device were 5% vs. 6%; P = 0.8 and 11% vs. 11%; P = 0.9 respectively. This retrospective analysis found that recanalization of CIA occlusions using a RED is safe and is associated with long-term clinical outcomes similar to that of standard crossing techniques. © 2018 Wiley Periodicals, Inc.

  20. Clinical significance of sleep bruxism on several occlusal and functional parameters.

    PubMed

    Ommerborn, Michelle A; Giraki, Maria; Schneider, Christine; Fuck, Lars Michael; Zimmer, Stefan; Franz, Matthias; Raab, Wolfgang Hans-michael; Schaefer, Ralf

    2010-10-01

    The aim of this study was to evaluate the association between various functional and occlusal parameters and sleep bruxism. Thirty-nine (39) sleep bruxism patients and 30 controls participated in this investigation. The assessment of sleep bruxism was performed using the Bruxcore Bruxism-Monitoring Device (BBMD) combined with a new computer-based analyzing method. Sixteen functional and/or occlusal parameters were recorded. With a mean slide of 0.95 mm in the sleep bruxism group and a mean slide of 0.42 mm in the control group (Mann Whitney U test; p<0.003), results solely demonstrated a significant group difference regarding the length of a slide from centric occlusion to maximum intercuspation. The results suggest that the slightly pronounced slide could be of clinical importance in the development of increased wear facets in patients with current sleep bruxism activity. Following further evaluation including polysomnographic recordings, the BBMD combined with this new analyzing technique seems to be a clinically feasible instrument that allows the practitioner to quantify abrasion over a short period.

  1. Multicentre experience with the BridgePoint devices to facilitate recanalisation of chronic total coronary occlusions through controlled subintimal re-entry.

    PubMed

    Werner, Gerald S; Schofer, Joachim; Sievert, Horst; Kugler, Chad; Reifart, Nicolaus J

    2011-06-01

    The major challenge for the interventional treatment of chronic total coronary occlusion (CTO) is a low primary success rate. A common problem is the passage of the recanalisation wire into a subintimal position. New devices, which were evaluated in the first multicentre study in CTOs resistant to a conventional wire approach, may help to facilitate a controlled re-entry into the true lumen. The aim of this study was to assess the safety and efficacy of this approach, with successful true lumen distal wire passage as the primary endpoint. Forty-two patients were enrolled in four centres with high expertise in PCI for CTOs. All CTOs were of at least three months duration, and were initially attempted with dedicated recanalisation wires. After failure to pass or creation of a subintimal dissection, the BridgePoint devices were applied, consisting of a ball-tipped catheter (CrossBoss) to pass the proximal occlusion cap, and a flat-shaped balloon catheter (Stingray catheter) to be inflated within the subintimal space to guide the re-entry into the true vessel lumen with a special wire (Stingray guidewire). The primary endpoint was met in 67% of all patients. A higher success rate seemed to be possible when all devices were used in sequenced beginning with the CrossBoss, and in the case of a subintimal passage, followed by the Stingray. True lumen re-entry failed because of the loss of distally contrast filling and thus loss of a target for re-entry, and by a failure to advance the Stingray balloon far enough distal and parallel to the distal lumen. There were no severe device related complications. In patients with complex CTOs referred to dedicated centres with high experience in CTOs, these results demonstrate the potential of a guided re-entry from a subintimal wire position by use of the BridgePoint devices.

  2. In vivo evaluation of DIAGNOdent for the quantification of occlusal dental caries.

    PubMed

    Khalife, Moufida A; Boynton, James R; Dennison, Joseph B; Yaman, Peter; Hamilton, James C

    2009-01-01

    The accurate diagnosis of non-cavitated occlusal caries is generally considered problematic. Induced fluorescence quantified by the DIAGNOdent device (KaVo) gives a reading from 0-99, which may help in the caries diagnostic process. There is some controversy around the implication of increased severity of decay with increased DIAGNOdent readings. This in vivo study assessed the correlation of depth and volume of decay as it was removed by traditional rotary handpieces with DIAGNOdent readings and determined sensitivities/specificities of the device at different cut-off points. Included in the current study were 31 patients providing 60 permanent molar and premolar occlusal surfaces suspected of dentinal decay. DIAGNOdent readings were recorded, along with lesion depth (as measured by periodontal probe) and volume measurements (as calculated from measuring the mass of a polyvinyl siloxane impression of the cavity, divided by the material's calculated density). Clinical detection of decay at the DEJ was used as the gold-standard to calculate an appropriate cut-off. Pearson correlation coefficients indicated that DIAGNOdent readings were weakly correlated with lesion depth (r = 0.47) and lesion volume (also r = 0.47). An appropriate cut-off point for the sample in the current study was calculated between 35 and 40; a more specific cut-off point could not be determined due to the sample size distribution. It was concluded that the DIAGNOdent device should be used as an adjunct in the caries diagnosis and treatment planning process.

  3. A Retrospective Study of 1,526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus.

    PubMed

    Jin, Mei; Liang, Yong-Mei; Wang, Xiao-Fang; Guo, Bao-Jing; Zheng, Ke; Gu, Yan; Lyu, Zhen-Yu

    2015-09-05

    Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. Median age and median weight were 4.0 years (range: 0.3-52.0 years old) and 15.3 kg (range: 4.5-91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently.

  4. A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus

    PubMed Central

    Jin, Mei; Liang, Yong-Mei; Wang, Xiao-Fang; Guo, Bao-Jing; Zheng, Ke; Gu, Yan; Lyu, Zhen-Yu

    2015-01-01

    Background: Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. Methods: One thousand five hundred and twenty-six patients (537 boys, 989 girls) with PDA from January 1997 to September 2014 underwent descending aortogram and transcatheter occlusion procedure. We retrospectively analyzed data of these patients, including gender, age, weight, size and morphology of PDA, and devices used in transcatheter occlusion, outcomes, and postoperational complications. Results: Median age and median weight were 4.0 years (range: 0.3–52.0 years old) and 15.3 kg (range: 4.5–91.0 kg), respectively. Mean ductal diameter, aortic ductal diameter, ductal length, and pulmonary artery pressure were 3.50 ± 2.15 mm, 10.08 ± 2.46 mm, 7.49 ± 3.02 mm, and 30.21 ± 17.28 mmHg, respectively. Morphology of PDA assessed by descending aortogram was of type A in 1428 patients, type B in 6 patients, type C in 79 patients, type D in 4 patients, and type E in 9 patients according to the classification of Krichenko. Of all the 1526 patients, 1497 patients underwent transcatheter PDA closure, among which 1492 were successful. Devices used were Amplatzer duct occluder I (ADO I, 1280, 85.8%), Cook detachable coils (116, 7.8%), ADO II (ADO II, 68, 4.6%), muscular VSD occluder (12, 0.8%), and Amplatzer vascular plug (16, 1.0%). Conclusions: Excellent occlusion rates with low complication rates were achieved with all devices regardless of PDA types. With transcatheter occlusion technique and devices developing, more patients with PDA can be treated with transcatheter closure both safely and efficiently. PMID:26315073

  5. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference.

    PubMed

    Ono, Yumie; Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-11-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near-infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task-related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task-related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD.

  6. Diagnosis of occlusal dysesthesia utilizing prefrontal hemodynamic activity with slight occlusal interference

    PubMed Central

    Ishikawa, Yu; Munakata, Motohiro; Shibuya, Tomoaki; Shimada, Atsushi; Miyachi, Hideo; Wake, Hiroyuki; Tamaki, Katsushi

    2016-01-01

    Clinical diagnosis of occlusal dysesthesia (OD), also referred to as phantom bite syndrome, is currently based on the absence of objective occlusal discrepancy despite the persistent complaint of uncomfortable bite sensation. We previously demonstrated that the subjective feeling of occlusal discomfort generated by artificial occlusal interference can be objectively evaluated using prefrontal hemodynamic activity in young healthy individuals. The aim of this study was to investigate whether dental patients with and without OD show distinct prefrontal activity during grinding behavior with an occlusal interference. Six dental patients with OD (OD group) and eight patients without OD (control group) grinded piled occlusal strips placed between their first molars and reported their perception and discomfort thresholds during continuous monitoring of prefrontal hemodynamic activity with a portable functional near‐infrared spectroscopy. Although patients without OD showed the typical hemodynamic pattern of increased oxyhemoglobin and reduced deoxyhemoglobin (HHb) concentration, those with OD showed persistent incremental increases of HHb concentration that began at the loading of occlusal strips on their molars before they executed grinding. The intensities of the task‐related HHb activities showed statistically significant differences between OD and control groups, particularly at channel 3, arranged over the left frontal pole cortex. When the discrimination criterion was set using the intensity values of channel 3 from both groups, the overall accuracy of the OD discrimination was 92.9%. Although physiological interpretation has yet to be elucidated, the task‐related response of an increase in HHb may be a useful neuronal signature to characterize dental patients with OD. PMID:29744159

  7. Theoretical Study on the Mechanics of the Conjunct Gnatoprothetic Devices in the Context of Occlusive Function Rehabilitation

    PubMed Central

    POPESCU, M.R.; TRANĂ, F.; MANOLEA, H.; RAUTEN, ANE-MARIE; ȘURLIN, PETRA; DRAGOMIR, L.P.

    2014-01-01

    The partially intercalated edentation offers the practitioner the possibility of the functional rehabilitation of the dental arcades through conjunct gnato-prosthetic devices. The functions of the dento-maxilar device, disturbed by the presence of edentation, require a treatment approach so that, without pre-planning or estimating, the result can lead most of the times to failure in terms of functionality. Clinical evaluation associated with pre- and proprosthetic treatment can also impose, in some situations the evaluation of the dental units involved in prosthetic rehabilitation. The association and implementation of the prosthetic construction in the occlusive-articular ensemble, as well as the counterbalancing of the mastication forces per dental unit and whole interarch system, linked to the distribution of the forces at the level of the pillar teeth and prosthetic construction, represent the goal of this theoretical study. PMID:25729593

  8. Theoretical study on the mechanics of the conjunct gnatoprothetic devices in the context of occlusive function rehabilitation.

    PubMed

    Popescu, M R; Trană, F; Manolea, H; Rauten, Ane-Marie; Șurlin, Petra; Dragomir, L P

    2014-01-01

    The partially intercalated edentation offers the practitioner the possibility of the functional rehabilitation of the dental arcades through conjunct gnato-prosthetic devices. The functions of the dento-maxilar device, disturbed by the presence of edentation, require a treatment approach so that, without pre-planning or estimating, the result can lead most of the times to failure in terms of functionality. Clinical evaluation associated with pre- and proprosthetic treatment can also impose, in some situations the evaluation of the dental units involved in prosthetic rehabilitation. The association and implementation of the prosthetic construction in the occlusive-articular ensemble, as well as the counterbalancing of the mastication forces per dental unit and whole interarch system, linked to the distribution of the forces at the level of the pillar teeth and prosthetic construction, represent the goal of this theoretical study.

  9. Net current control device. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fugate, D.; Cooper, J.H.

    1998-11-01

    Net currents generally result in elevated magnetic fields because the alternate paths are distant from the circuit conductors. Investigations have shown that one of the primary sources of power frequency magnetic fields in residential buildings is currents that return to their source via paths other than the neutral conductors. As part of EPRI`s Magnetic Field Shielding Project, ferromagnetic devices, called net current control (NCC) devices, were developed and tested for use in reducing net currents on electric power cables and the resulting magnetic fields. Applied to a residential service drop, an NCC device reduces net current by forcing current offmore » local non-utility ground paths, and back onto the neutral conductor. Circuit models and basic design equations for the NCC concept were developed, and proof-of-principles tests were carried out on an actual residence with cooperation from the local utility. After proving the basic concepts, three prototype NCC devices were built and tested on a simulated neighborhood power system. Additional prototypes were built for testing by interested EPRI utility members. Results have shown that the NCC prototypes installed on residential service drops reduce net currents to milliampere levels with compromising the safety of the ground system. Although the focus was on application to residential service cables, the NCC concept is applicable to single-phase and three-phase distribution systems as well.« less

  10. Percutaneous left atrial appendage occlusion: Effect of device positioning on outcome.

    PubMed

    Wolfrum, Mathias; Attinger-Toller, Adrian; Shakir, Samera; Gloekler, Steffen; Seifert, Burkhardt; Moschovitis, Aris; Khattab, Ahmed; Maisano, Francesco; Meier, Bernhard; Nietlispach, Fabian

    2016-10-01

    The study in patients with percutaneous left atrial appendage (LAA) occlusion investigates clinical outcomes according to the position of the Amplatzer Cardiac Plug (ACP) disc. The ACP consists of a disc and an anchoring lobe. The disc is meant to cover the ostium of the LAA, but frequently retracts partially or completely into the neck of the LAA. It is not known whether a retracted disc affects outcome. Outcomes of 169 consecutive patients (age 73.1 ± 10.4 years; 76% male) with successful LAA closure were analyzed according to the position of the ACP disc: group A had complete coverage of the LAA ostium; in group B the disc prolapsed partially or completely into the LAA-neck. Transesophageal echocardiography was performed 1-6 months after ACP implantation. The safety endpoint was the composite of clinically significant pericardial effusion, device embolization, procedure-related stroke/transient ischemic attack (TIA), major bleeding, or device thrombus. The efficacy endpoint was the composite of death, neurological events (ischemic and hemorrhagic stroke, TIA), or systemic embolism during follow-up. Group A comprised 76 patients (age 73.0 ± 9.9 years; 74% male) and group B 93 patients (age 73.3 ± 10.9 years; 79% male). Mean CHA 2 DS 2 -Vasc score and HASBLED score were 4.2 ± 1.7 (group A 4.3 ± 1.6; group B 4.2 ± 1.8) and 2.9 ± 1.1 (group A 2.9 ± 1.0; group B 3.0 ± 1.2), respectively. Mean follow-up of the study population was 13.0 ± 10.4 months. Overall, the composite safety and efficacy endpoints occurred in 20 (12%) and 6 patients (4%), respectively. There was no significant difference between groups A and B in the occurrence of the safety endpoint (13% vs. 11%, P = 0.64), or the efficacy endpoint (4% vs. 3%, P = 1.0). No evidence for a difference in the occurrence of the safety and efficacy endpoint was found between patients with complete vs. incomplete ACP disc coverage of the LAA ostium. The risk of

  11. Frequency behavior of the residual current devices

    NASA Astrophysics Data System (ADS)

    Erdei, Z.; Horgos, M.; Lung, C.; Pop-Vadean, A.; Muresan, R.

    2017-01-01

    This paper presents an experimental investigation into the operating characteristic of residual current devices when in presence of a residual current at a frequency of 60Hz. In order to protect persons and equipment effectively the residual current devices are made to be very sensitive to the ground fault current or the touch current. Because of their high sensitivity the residual current circuit breakers are prone to tripping under no-fault conditions.

  12. The Amplatz canine duct occluder: a novel device for patent ductus arteriosus occlusion.

    PubMed

    Nguyenba, Thaibinh P; Tobias, Anthony H

    2007-11-01

    The Amplatz canine duct occluder (ACDO) is a nitinol mesh device with a short waist that separates a flat distal disc from a cupped proximal disc. The device is designed to conform to the morphology of the canine patent ductus arteriosus (PDA). PDA dimensions are determined by angiography, and a guiding catheter is advanced into the main pulmonary artery via the aorta and PDA. An ACDO with a waist diameter approximately twice the angiographic minimal ductal diameter (MDD) is advanced via the catheter using an attached delivery cable until the flat distal disc deploys within the main pulmonary artery. The partially deployed ACDO, guiding catheter, and delivery cable are retracted until the distal disc engages the pulmonic ostium of the PDA. With the delivery cable stabilized, the catheter is retracted to deploy the waist across the pulmonic ostium and cupped proximal disc within the ductal ampulla. Tension on the delivery cable is released, and correct ACDO positioning and stability are confirmed by observing that the device assumes its native shape, back-and-forth maneuvering of the delivery cable, and a small contrast injection made through the guiding catheter. The delivery cable is detached and removed with the guiding catheter. To assess for any residual ductal flow, an angiogram is performed at the conclusion of the procedure, followed by Doppler echocardiography at 1 day and 3 months post-procedure. PDA occlusion in dogs with the ACDO is straightforward and extremely effective across a wide range of body weights, somatotypes, MDDs, and ductal morphologies.

  13. New re-entry device for revascularization of chronic coronary total occlusions: preliminary single Japanese center experience.

    PubMed

    Tsuchikane, Etsuo; Kimura, Masashi; Suzuki, Takahiko; Habara, Maoto; Kurita, Tairo; Tanaka, Nobuyoshi; Nasu, Kenya; Ito, Tatsuya; Kinoshita, Yoshihisa; Wyman, R Michael

    2012-08-01

    Although retrograde approach for coronary chronic total occlusion (CTO) has been introduced, the procedure is still time and resource consuming. A simplified antegrade approach mightbe another resort. The aim of this study was to evaluate a new device designed to facilitate guidewire re-entry into the true lumen of a CTO from the adjacent subintimal space. Patients with CTO were entered into a prospective registry regardless of lesion characteristics. A new metal-tip catheter was used initially in primary use cases. If it created subintimal tracking, a new re-entry tool (a flat balloon with 2 exit ports offset by 180 degrees) was used as a platform to attempt guidewire penetration into the distal true lumen. In rescue use cases after unsuccessful conventional wiring, the re-entry procedure was subsequently attempted. In 11 CTO lesions attempted, device success was achieved in 8 cases (72.7%). Re-entry procedure success rate was higher in primary use cases (80%) compared to rescue use cases (33.3%). Retrograde approach was conducted immediately after unsuccessful antegrade procedure using this device in the other 3 cases and successful recanalization was achieved in all cases. All lesions were stented, resulting in TIMI 3 flow without major complications. A new coronary re-entry device may provide another strategic option in the antegrade approach to recanalize CTOs.

  14. Passive fault current limiting device

    DOEpatents

    Evans, Daniel J.; Cha, Yung S.

    1999-01-01

    A passive current limiting device and isolator is particularly adapted for use at high power levels for limiting excessive currents in a circuit in a fault condition such as an electrical short. The current limiting device comprises a magnetic core wound with two magnetically opposed, parallel connected coils of copper, a high temperature superconductor or other electrically conducting material, and a fault element connected in series with one of the coils. Under normal operating conditions, the magnetic flux density produced by the two coils cancel each other. Under a fault condition, the fault element is triggered to cause an imbalance in the magnetic flux density between the two coils which results in an increase in the impedance in the coils. While the fault element may be a separate current limiter, switch, fuse, bimetal strip or the like, it preferably is a superconductor current limiter conducting one-half of the current load compared to the same limiter wired to carry the total current of the circuit. The major voltage during a fault condition is in the coils wound on the common core in a preferred embodiment.

  15. Passive fault current limiting device

    DOEpatents

    Evans, D.J.; Cha, Y.S.

    1999-04-06

    A passive current limiting device and isolator is particularly adapted for use at high power levels for limiting excessive currents in a circuit in a fault condition such as an electrical short. The current limiting device comprises a magnetic core wound with two magnetically opposed, parallel connected coils of copper, a high temperature superconductor or other electrically conducting material, and a fault element connected in series with one of the coils. Under normal operating conditions, the magnetic flux density produced by the two coils cancel each other. Under a fault condition, the fault element is triggered to cause an imbalance in the magnetic flux density between the two coils which results in an increase in the impedance in the coils. While the fault element may be a separate current limiter, switch, fuse, bimetal strip or the like, it preferably is a superconductor current limiter conducting one-half of the current load compared to the same limiter wired to carry the total current of the circuit. The major voltage during a fault condition is in the coils wound on the common core in a preferred embodiment. 6 figs.

  16. [Relationship between Occlusal Discomfort Syndrome and Occlusal Threshold].

    PubMed

    Munakata, Motohiro; Ono, Yumie; Hayama, Rika; Kataoka, Kanako; Ikuta, Ryuhei; Tamaki, Katsushi

    2016-03-01

    Occlusal dysesthesia has been defined as persistent uncomfortable feelings of intercuspal position continuing for more than 6 months without evidence of physical occlusal discrepancy. The problem often occurs after occlusal intervention by dental care. Although various dental treatments (e. g. occlusal adjustment, orthodontic treatment and prosthetic reconstruction) are attempted to solve occlusal dysesthesia, they rarely reach a satisfactory result, neither for patients nor dentists. In Japan, these symptoms are defined by the term "Occlusal discomfort syndrome" (ODS). The aim of this study was to investigate the characteristics of ODS with the simple occlusal sensory perceptive and discriminative test. Twenty-one female dental patients with ODS (mean age 55.8 ± 19.2 years) and 21 age- and gender-matched dental patients without ODS (mean age 53.1 ± 16.8 years) participated in the study. Upon grinding occlusal registration foils that were stacked to different thicknesses, participants reported the thicknesses at which they recognized the foils (recognition threshold) and felt discomfort (discomfort threshold). Although there was no significant difference in occlusal recognition thresholds between the two patient groups, the discomfort threshold was significantly smaller in the patients with ODS than in those without ODS. Moreover, the recognition threshold showed an age-dependent increase in patients without ODS, whereas it remained comparable between the younger (< 60 years old) and elderly (60 years old or more) patient subgroups with ODS. These results suggest that occlusal discomfort threshold rather than recognition threshold is an issue in ODS. The foil grinding procedure is a simple and useful method to evaluate occlusal perceptive and discriminative abilities in patients with ODS.

  17. In vitro and in vivo Evaluation of a Shape Memory Polymer Foam-over-Wire Embolization Device Delivered in Saccular Aneurysm Models

    PubMed Central

    Boyle, Anthony J.; Landsman, Todd L.; Wierzbicki, Mark A.; Nash, Landon D.; Hwang, Wonjun; Miller, Matthew W.; Tuzun, Egemen; Hasan, Sayyeda M.; Maitland, Duncan J.

    2015-01-01

    Current endovascular therapies for intracranial saccular aneurysms result in high recurrence rates due to poor tissue healing, coil compaction, and aneurysm growth. We propose treatment of saccular aneurysms using shape memory polymer (SMP) foam to improve clinical outcomes. SMP foam-over-wire (FOW) embolization devices were delivered to in vitro and in vivo porcine saccular aneurysm models to evaluate device efficacy, aneurysm occlusion, and acute clotting. FOW devices demonstrated effective delivery and stable implantation in vitro. In vivo porcine aneurysms were successfully occluded using FOW devices with theoretical volume occlusion values greater than 72% and rapid, stable thrombus formation. PMID:26227115

  18. Current responsive devices for synchronous generators

    DOEpatents

    Karlicek, R.F.

    1983-09-27

    A device for detecting current imbalance between phases of a polyphase alternating current generator. A detector responds to the maximum peak current in the generator, and detecting means generates an output for each phase proportional to the peak current of each phase. Comparing means generates an output when the maximum peak current exceeds the phase peak current. 11 figs.

  19. Current responsive devices for synchronous generators

    DOEpatents

    Karlicek, Robert F.

    1983-01-01

    A device for detecting current imbalance between phases of a polyphase alternating current generator. A detector responds to the maximum peak current in the generator, and detecting means generates an output for each phase proportional to the peak current of each phase. Comparing means generates an output when the maximum peak current exceeds the phase peak current.

  20. Interobserver variability in the assessment of aneurysm occlusion with the WEB aneurysm embolization system.

    PubMed

    Fiorella, David; Arthur, Adam; Byrne, James; Pierot, Laurent; Molyneux, Andy; Duckwiler, Gary; McCarthy, Thomas; Strother, Charles

    2015-08-01

    The WEB (WEB aneurysm embolization system, Sequent Medical, Aliso Viejo, California, USA) is a self-expanding, nitinol, mesh device designed to achieve aneurysm occlusion after endosaccular deployment. The WEB Occlusion Scale (WOS) is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with intrasaccular mesh implants. This study was performed to assess the interobserver variability of the WOS. Seven experienced neurovascular specialists were trained to apply the WOS. These physicians independently reviewed angiographic image sets from 30 patients treated with the WEB under blinded conditions. No additional clinical information was provided. Raters graded each image according to the WOS (complete occlusion, residual neck or residual aneurysm). Final statistics were calculated using the dichotomous outcomes of complete occlusion or incomplete occlusion. The interobserver agreement was measured by the generalized κ statistic. In this series of 30 test case aneurysms, observers rated 12-17 as completely occluded, 3-9 as nearly completely occluded, and 9-11 as demonstrating residual aneurysm filling. Agreement was perfect across all seven observers for the presence or absence of complete occlusion in 22 of 30 cases. Overall, interobserver agreement was substantial (κ statistic 0.779 with a 95% CI of 0.700 to 0.857). The WOS allows a consistent means of reporting angiographic occlusion for aneurysms treated with the WEB device. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Latest recanalization techniques for complex superficial femoral artery occlusions.

    PubMed

    Gonzalez, L; Chen, A; Lin, P H; Pisimisis, G; Barshes, N R; Bechara, C F; Kougias, P

    2012-08-01

    Complex, long segment lesions of the superficial femoral artery (SFA) are common, occurring in 40% of patients with peripheral vascular disease. In particular, chronic total occlusions (CTOs) continue to pose a challenge in the endovascular management of SFA disease. Several conventional wire and catheter based techniques have been described including subintimal recanalization and retrograde techniques. In addition, advances in endovascular technology have led to the development of a series of new devices aimed specifically at facilitating the crossing of long segment SFA occlusions or establishing re-entry of the true lumen. Here we present an overview of the minimally invasive techniques used to recanalize CTOs of the SFA and the latest specialized devices available for both recanalization and re-entry, as well as a summary of the literature supporting their application.

  2. Umbrella occlusion of persistent arterial duct in children under two years.

    PubMed Central

    Gatzoulis, M A; Rigby, M L; Redington, A N

    1994-01-01

    OBJECTIVE--To assess the use of trans-catheter occlusion of a persistent arterial duct in symptomatic children < 2 years of age. DESIGN--Descriptive study of selected, non-randomised infants with persistent arterial duct who underwent attempted umbrella occlusion. SETTING--Tertiary referral centre. PATIENTS--Between June 1990 and April 1993, 29 young children with a symptomatic persistent arterial duct underwent attempted transcatheter occlusion. Their age ranged from 1.5 to 23 months, with the youngest infant weighing 2.9 kg. The diagnosis was established before operation in all patients by cross sectional echocardiography. INTERVENTION--Transcatheter occlusion of a haemodynamically important persistent arterial duct was performed with the Rashkind ductal umbrella. In the past year the front loading technique has been used to place the 12 mm umbrella through a 6 F (French) sheath and the 17 mm device through a 8 F sheath so extending the indications for their use. RESULTS--Umbrellas were successfully placed in 25 (86.2%) infants and there was symptomatic improvement in all. There were no deaths or severe complications. The four failures occurred early in the series. They were caused by kinking of the 11 F sheath in two cases and embolisation into the left pulmonary artery in one case. The procedure was abandoned in the fourth case because of a large duct. Only three of the 25 patients had small residual shunts at one year follow up (all with 17 mm devices) but no stenosis or turbulence was noted in any of the patients. CONCLUSION--The transcatheter occlusion of persistent arterial duct in young children with symptoms is a safe alternative to surgery. The new front loading umbrella technique enables successful ductal closure in even smaller infants than earlier devices. Images PMID:7833196

  3. Efficacy of biofeedback therapy via a mini wireless device on sleep bruxism contrasted with occlusal splint: a pilot study

    PubMed Central

    Gu, WeiPing; Yang, Jie; Zhang, FeiMin; Yin, XinMin; Wei, XiaoLong; Wang, Chen

    2015-01-01

    Abstract The putative causes of bruxism are multifactorial and there are no definite measures for bruxism management. The aim of this study was to evaluate the efficacy of biofeedback therapy on sleep bruxism, compared with occlusal splint. Twenty-four volunteers with sleep bruxism were divided into two groups: the GTB group that were treated with biofeedback therapy (n  = 12) and the GTO group that were treated with occlusal splint (n  = 12). A mini pressure sensor integrated with a monitoring circuit by use of a maxillary biofeedback splint was fabricated. To foster the relaxation of the masticatory muscles and the nervous system, the wireless device received signals from bruxism events and vibrations alerted the bruxer when the threshold was exceeded. Total episodes and average duration of bruxism events during 8 hours of sleep were analyzed with the monitoring program (TRMY1.0). After 6 and 12 weeks, the episodes (P  =  0.001) and duration (P < 0.05) in the GTB group declined dramatically. In contrast, there were no significant differences in the GTO group after the treatment (P > 0.05). Furthermore, the episodes had significant differences between the GTB group and the GTO group after the same period of treatment (P  =  0.000). The results suggest that biofeedback therapy may be an effective and convenient measure for mild bruxers, when compared with occlusal splint therapy. The mini wireless biofeedback method may be of value for the diagnosis and management of bruxism in the future. PMID:25859272

  4. Time to aortic occlusion: It's all about access.

    PubMed

    Romagnoli, Anna; Teeter, William; Pasley, Jason; Hu, Peter; Hoehn, Melanie; Stein, Deborah; Scalea, Thomas; Brenner, Megan

    2017-12-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less invasive method of proximal aortic occlusion compared with resuscitative thoracotomy with aortic cross-clamping (RTACC). This study compared time to aortic occlusion with REBOA and RTACC, both including and excluding time required for common femoral artery (CFA) cannulation. This was a retrospective, single-institution review of REBOA or RTACC performed between February 2013 and January 2016. Time of skin incision to aortic cross-clamp for RTACC, time required for CFA cannulation by percutaneous and open methods, and time from guide-wire insertion to balloon inflation at Zone 1 for REBOA, were obtained from videographic recordings. Eighteen RTACC and 21 REBOAs were performed. Median (Q1, Q3) time from skin incision to aortic cross-clamping was 317 seconds (227, 551 seconds). Median (Q1, Q3) time from start of arterial access to Zone 1 balloon occlusion was 474 seconds (431, 572 seconds) (vs. RTACC, p = 0.01). All REBOA procedures were performed with the same device. The median time to complete CFA cannulation was 247 seconds (range, 164-343 seconds), with no difference between percutaneous or open procedures (p = 0.07). The median (Q1, Q3) time to aortic occlusion in REBOA once arterial access had been established was 245 seconds (179, 295.5 seconds), which was significantly shorter than RTACC (p = 0.003). Once CFA access is achieved, time to aortic occlusion is faster with REBOA. Time to aortic occlusion is less than the time required to cannulate the CFA either by percutaneous or open approaches, emphasizing the importance of accurate and expedient CFA access. Resuscitative endovascular balloon occlusion of the aorta may represent a feasible alternative to thoracotomy for aortic occlusion. Time to aortic occlusion will likely decrease with the advent of newer REBOA technology. The rate-limiting portion of REBOA continues to be obtaining CFA access. Therapeutic, level V.

  5. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

    PubMed

    Kim, Yongsik; Oh, Tae-Ju; Misch, Carl E; Wang, Hom-Lay

    2005-02-01

    Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

  6. Left Atrial Appendage Electrical Isolation and Concomitant Device Occlusion to Treat Persistent Atrial Fibrillation: A First-in-Human Safety, Feasibility, and Efficacy Study.

    PubMed

    Panikker, Sandeep; Jarman, Julian W E; Virmani, Renu; Kutys, Robert; Haldar, Shouvik; Lim, Eric; Butcher, Charles; Khan, Habib; Mantziari, Lilian; Nicol, Edward; Foran, John P; Markides, Vias; Wong, Tom

    2016-07-01

    Left atrial appendage (LAA) electric isolation is reported to improve persistent atrial fibrillation (AF) ablation outcomes. However, loss of LAA mechanical function may increase thromboembolic risk. Concomitant LAA electric isolation and occlusion as part of conventional AF ablation has never been tested in humans. We therefore evaluated the feasibility, safety, and efficacy of LAA electric isolation and occlusion in patients undergoing long-standing persistent AF ablation. Patients with long-standing persistent AF (age, 68±7 years; left atrium diameter, 46±3 mm; and AF duration, 25±15 months) underwent AF ablation, LAA electric isolation, and occlusion. Outcomes were compared with a balanced (1:2 ratio) control group who had AF ablation alone. Among 22 patients who underwent ablation, LAA electric isolation was possible in 20. Intraprocedural LAA reconnection occurred in 17 of 20 (85%) patients, predominantly at anterior and superior locations. All were reisolated. LAA occlusion was successful in all 20 patients. There were no major periprocedural complications. Imaging at 45 days and 9 months confirmed satisfactory device position and excluded pericardial effusion. One of twenty (5%) patients had a gap of ≥5 mm requiring anticoagulation. Nineteen of twenty (95%) patients stopped warfarin at 3 months. Without antiarrhythmic drugs, freedom from AF at 12 months after a single procedure was significantly higher in the study group (19/20, 95%) than in the control group (25/40, 63%), P=0.036. Freedom from atrial arrhythmias was demonstrated in 12 of 20 (60%) and 18 of 20 (90%) patients after 1 and ≤2 procedures (mean, 1.3), respectively. Persistent AF ablation, LAA electric isolation, and mechanical occlusion can be performed concomitantly. This technique may improve the success of persistent AF ablation while obviating the need for chronic anticoagulation. URL: https://clinicaltrials.gov. Unique identifier: NCT02028130. © 2016 American Heart Association, Inc.

  7. Motor current signature analysis method for diagnosing motor operated devices

    DOEpatents

    Haynes, Howard D.; Eissenberg, David M.

    1990-01-01

    A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.

  8. Does partial occlusion promote normal binocular function?

    PubMed

    Li, Jingrong; Thompson, Benjamin; Ding, Zhaofeng; Chan, Lily Y L; Chen, Xiang; Yu, Minbin; Deng, Daming; Hess, Robert F

    2012-10-03

    There is growing evidence that abnormal binocular interactions play a key role in the amblyopia syndrome and represent a viable target for treatment interventions. In this context the use of partial occlusion using optical devices such as Bangerter filters as an alternative to complete occlusion is of particular interest. The aims of this study were to understand why Bangerter filters do not result in improved binocular outcomes compared to complete occlusion, and to compare the effects of Bangerter filters, optical blur and neutral density (ND) filters on normal binocular function. The effects of four strengths of Bangerter filters (0.8, 0.6, 0.4, 0.2) on letter and vernier acuity, contrast sensitivity, stereoacuity, and interocular suppression were measured in 21 observers with normal vision. In a subset of 14 observers, the partial occlusion effects of Bangerter filters, ND filters and plus lenses on stereopsis and interocular suppression were compared. Bangerter filters did not have graded effect on vision and induced significant disruption to binocular function. This disruption was greater than that of monocular defocus but weaker than that of ND filters. The effect of the Bangerter filters on stereopsis was more pronounced than their effect on monocular acuity, and the induced monocular acuity deficits did not predict the induced deficits in stereopsis. Bangerter filters appear to be particularly disruptive to binocular function. Other interventions, such as optical defocus and those employing computer generated dichoptic stimulus presentation, may be more appropriate than partial occlusion for targeting binocular function during amblyopia treatment.

  9. Procedural and Early Outcomes of Two Re-entry Devices for Subintimal Recanalization of Aortoiliac and Femoropopliteal Chronic Total Occlusions.

    PubMed

    Vuruskan, Ertan; Saracoglu, Erhan

    2017-01-01

    Subintimal angioplasty is a common treatment choice for chronic total occlusions (CTO) in the iliac and femoropopliteal arteries. This article describes the technical aspects and early outcomes of two different re-entry devices and comparison with manual re-entry technique. A retrospective review of 61 patients (re-entry group) treated with Outback or Pioneer Plus catheters was carried out. A matched cohort of patients (n=62) who underwent lower extremity interventions without the use of re-entry devices (manual re-entry group) were also analyzed (overall 123 patients were analyzed). Procedural success, procedural durations, patency estimates, ankle-brachial indices, and complications were analyzed. Sixty-one patients underwent Outback or Pioneer Plus guided subintimal recanalization. After the procedure, ankle-brachial indices significantly increased in all patients during follow-up. Primary patency for the entire cohort was 83% in the first month. When the re-entry device group was compared with manual re-entry group, no difference was found with respect to success, complication, and patencies between the two groups during follow-up. However, procedure duration and the amount of contrast agent used was significantly decreased in re-entry groups (p<0.001). Also, re-entry time was significantly decreased in Pioneer plus group according to Outback group (p<0.001). Recanalization of CTO using re-entry devices for aortoiliac or femoropopliteal arteries is safe and effective. These devices shorten the procedure time, the re-entry time, reduce radiation risk, and reduce the amount of contrast agent employed.

  10. Method and apparatus for measuring low currents in capacitance devices

    DOEpatents

    Kopp, M.K.; Manning, F.W.; Guerrant, G.C.

    1986-06-04

    A method and apparatus for measuring subnanoampere currents in capacitance devices is reported. The method is based on a comparison of the voltages developed across the capacitance device with that of a reference capacitor in which the current is adjusted by means of a variable current source to produce a stable voltage difference. The current varying means of the variable current source is calibrated to provide a read out of the measured current. Current gain may be provided by using a reference capacitor which is larger than the device capacitance with a corresponding increase in current supplied through the reference capacitor. The gain is then the ratio of the reference capacitance to the device capacitance. In one illustrated embodiment, the invention makes possible a new type of ionizing radiation dose-rate monitor where dose-rate is measured by discharging a reference capacitor with a variable current source at the same rate that radiation is discharging an ionization chamber. The invention eliminates high-megohm resistors and low current ammeters used in low-current measuring instruments.

  11. Current-limiting challenges for all-spin logic devices

    PubMed Central

    Su, Li; Zhang, Youguang; Klein, Jacques-Olivier; Zhang, Yue; Bournel, Arnaud; Fert, Albert; Zhao, Weisheng

    2015-01-01

    All-spin logic device (ASLD) has attracted increasing interests as one of the most promising post-CMOS device candidates, thanks to its low power, non-volatility and logic-in-memory structure. Here we investigate the key current-limiting factors and develop a physics-based model of ASLD through nano-magnet switching, the spin transport properties and the breakdown characteristic of channel. First, ASLD with perpendicular magnetic anisotropy (PMA) nano-magnet is proposed to reduce the critical current (Ic0). Most important, the spin transport efficiency can be enhanced by analyzing the device structure, dimension, contact resistance as well as material parameters. Furthermore, breakdown current density (JBR) of spin channel is studied for the upper current limitation. As a result, we can deduce current-limiting conditions and estimate energy dissipation. Based on the model, we demonstrate ASLD with different structures and channel materials (graphene and copper). Asymmetric structure is found to be the optimal option for current limitations. Copper channel outperforms graphene in term of energy but seriously suffers from breakdown current limit. By exploring the current limit and performance tradeoffs, the optimization of ASLD is also discussed. This benchmarking model of ASLD opens up new prospects for design and implementation of future spintronics applications. PMID:26449410

  12. Mechanical Recanalization of Subacute Vessel Occlusion in Peripheral Arterial Disease with a Directional Atherectomy Catheter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massmann, Alexander, E-mail: Alexander.Massmann@uks.eu; Katoh, Marcus; Shayesteh-Kheslat, Roushanak

    2012-10-15

    Purpose: To retrospectively examine the technical feasibility and safety of directional atherectomy for treatment of subacute infrainguinal arterial vessel occlusions. Methods: Five patients (one woman, four men, age range 51-81 years) with peripheral arterial disease who experienced sudden worsening of their peripheral arterial disease-related symptoms during the last 2-6 weeks underwent digital subtraction angiography, which revealed vessel occlusion in native popliteal artery (n = 4) and in-stent occlusion of the superficial femoral artery (n = 1). Subsequently, all patients were treated by atherectomy with the SilverHawk (ev3 Endovascular, USA) device. Results: The mean diameter of treated vessels was 5.1 {+-}more » 1.0 mm. The length of the occlusion ranged 2-14 cm. The primary technical success rate was 100%. One patient experienced a reocclusion during hospitalization due to heparin-induced thrombocytopenia. There were no further periprocedural complications, in particular no peripheral embolizations, until hospital discharge or during the follow-up period of 1 year. Conclusion: The recanalization of infrainguinal arterial vessel occlusions by atherectomy with the SilverHawk device is technically feasible and safe. In our limited retrospective study, it was associated with a high technical success rate and a low procedure-related complication rate.« less

  13. Time Sequence Evaluation of Biliary Stent Occlusion by Dissection Analysis of Retrieved Stents.

    PubMed

    Kwon, Chang-Il; Gromski, Mark A; Sherman, Stuart; Easler, Jeffrey J; El Hajj, Ihab I; Watkins, James; Fogel, Evan L; McHenry, Lee; Lehman, Glen A

    2016-08-01

    Multiple factors can affect the occlusion of plastic stents. Previous data demonstrate that side holes may induce more biofilm formation probably via microturbulence and bile flow disturbances that could lead to occlusion. These results, however, have not been replicated in subsequent clinical studies with different methods. The objective of this study is to evaluate the physical characteristics of plastic stent occlusion over time. This is a plastic stent sequential analysis study. Biliary stents removed via ERCP from February 24, 2015, to June 2, 2015, were included. One hundred and forty-eight retrieved straight-type plastic stents were longitudinally cut by a custom-made cutting device. These dissected stents were then evaluated in detail with regard to the location of stent occlusion and the stent patency period. Location of stent occlusive debris was the primary outcome in this study. Biofilm formations and occlusions by debris were sequentially but separately tallied. Biofilm formations were initially seen around the side hole areas within 30 days and spread to the entire stent by 60 days. Then, occlusion process by debris was mainly initiated by 80 days and progressed to full occlusion by median of 90 days. Although some occlusions were also observed around the side hole areas within 30 days, affected areas were more widely observed after biofilm formation. This study is the first to attempt to describe the distribution of stent occlusions over time. These observations may help guide future stent development.

  14. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    NASA Astrophysics Data System (ADS)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  15. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonsalves, Carin F., E-mail: Carin.Gonsalves@mail.tju.edu; Eschelman, David J.; Sullivan, Kevin L.

    2003-04-15

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine cathetermore » dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access

  16. CT angiography for one-year follow-up of intracranial aneurysms treated with the WEB device: Utility in evaluating aneurysm occlusion and WEB compression at one year.

    PubMed

    Raoult, Hélène; Eugène, François; Le Bras, Anthony; Mineur, Géraldine; Carsin-Nicol, Béatrice; Ferré, Jean-Christophe; Gauvrit, Jean-Yves

    2018-03-07

    The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  17. Treatment of Angio-Seal-Related Femoral Artery Occlusion Using Directional Atherectomy-Primary Results and Midterm Follow-Up.

    PubMed

    Babaev, Anvar; Gokhale, Rohit; Zavlunova, Susanna; Attubato, Michael

    2016-11-01

    We describe a novel approach for the endovascular treatment of femoral artery occlusion as a result of Angio-Seal closure device deployment. Angio-Seal is the most commonly used vascular closure device following percutaneous coronary and peripheral catheterizations worldwide. A rare complication of Angio-Seal deployment is an occlusion of the femoral artery leading to limb ischemia requiring revascularization. Given its unique ability to cut both atherosclerotic plaque and the Angio-Seal anchor with a collagen plug at operator-directed planes, TurboHawk/HawkOne atherectomy device can be a fast and effective approach to treat Angio-Seal-associated femoral artery occlusions. We studied 13 consecutive patients who developed Angio-Seal-associated femoral artery occlusions that occurred from 3 hours to several weeks after catheterization. These patients were successfully treated with TurboHawk/HawkOne directional atherectomy followed by balloon angioplasty with no complications. During a mean follow-up period of 20.4 ± 17.3 months, 12 patients remained claudication free with no evidence of obstructive arterial disease of the treated segment on imaging studies. One patient developed restenosis that was treated with repeat atherectomy and balloon angioplasty following which he was asymptomatic at follow-up. The use of directional atherectomy followed by balloon angioplasty is a quick, safe, and effective endovascular approach to treating Angio-Seal-associated femoral artery occlusions. It is associated with an excellent success rate, no complications, and good midterm outcomes.

  18. Evaluation of the Alteration of Occlusal Distribution in Unilateral Free-End and Intermediate Missing Cases.

    PubMed

    Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei

    2017-02-01

    The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.

  19. Diffusion-weighted imaging score of the brain stem: A predictor of outcome in acute basilar artery occlusion treated with the Solitaire FR device.

    PubMed

    Mourand, I; Machi, P; Nogué, E; Arquizan, C; Costalat, V; Picot, M-C; Bonafé, A; Milhaud, D

    2014-06-01

    The prognosis for ischemic stroke due to acute basilar artery occlusion is very poor: Early recanalization remains the main factor that can improve outcomes. The baseline extent of brain stem ischemic damage can also influence outcomes. We evaluated the validity of an easy-to-use DWI score to predict clinical outcome in patients with acute basilar artery occlusion treated by mechanical thrombectomy. We analyzed the baseline clinical and DWI parameters of 31 patients with acute basilar artery occlusion, treated within 24 hours of symptom onset by using a Solitaire FR device. The DWI score of the brain stem was assessed with a 12-point semiquantitative score that separately considered each side of the medulla, pons, and midbrain. Clinical outcome was assessed at 180 days by using the mRS. According to receiver operating characteristic analyses, the cutoff score determined the optimal positive predictive value for outcome. The Spearman rank correlation coefficient assessed the correlation between the DWI brain stem score and baseline characteristics. Successful recanalization (Thrombolysis in Cerebral Infarction 3-2b) was achieved in 23 patients (74%). A favorable outcome (mRS ≤ 2) was observed in 11 patients (35%). An optimal DWI brain stem score of <3 predicted a favorable outcome. The probability of a very poor outcome (mRS ≥ 5) if the DWI brain stem score was ≥5 reached 80% (positive predictive value) and 100% if this score was ≥6. Interobserver reliability of the DWI brain stem score was excellent, with an intraclass correlation coefficient of 0.97 (95% CI, 0.96-0.99). The DWI brain stem score was significantly associated with baseline tetraplegia (P = .001) and coma (P = .005). In patients with acute basilar artery occlusion treated by mechanical thrombectomy, the baseline DWI brain lesion score seems to predict clinical outcome. © 2014 by American Journal of Neuroradiology.

  20. The current role of vascular stents.

    PubMed

    Busquet, J

    1993-09-01

    The limitations of percutaneous balloon angioplasty have favoured the development and the use of vascular endoprostheses or stents. These thin-walled metal devices maintain after expansion, an optimal and constant diameter for the vascular lumen. Restenosis, dissection, abrupt closure, residual stenosis or re-opened total occlusion represent appropriate indications for stenting. A large experience with non-coronary application of stents is currently available in iliac, femoro-popliteal and renal arteries, aorta, large veins.

  1. Endovascular Mechanical Recanalisation of Acute Carotid-T Occlusions: A Single-Center Retrospective Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fesl, Gunther, E-mail: gunther.fesl@med.uni-muenchen.de; Wiesmann, Martin; Patzig, Maximilian

    2011-04-15

    Purpose: Acute carotid-T occlusion generally responds poorly to thrombolysis. Endovascular mechanical thrombectomy (EMT) seems to be a promising alternative. However, there are few data on EMT in carotid-T occlusions. Materials and Methods: We reviewed data of 14 consecutive patients with acute carotid-T occlusions treated with mechanical recanalisation devices. A clot separation/aspiration system was used in 11 patients; different other mechanical retriever devices were used in seven patients; and stents were used in four patients. Modified Rankin Scale scores at 90 days were recorded to assess functional outcome. Results: Six women and eight men were included in the study. Mean patientmore » age was 59.2 years; median National Institute of Health Stroke Scale score on admission was 19; and mean time to treatment was 4.2 h. Successful recanalisation (Thrombolysis in Myocardial Infarction [TIMI] score II and III) was achieved in 11 patients (78.6%). Seven patients (50.0%) were treated with more than one device, leading to successful recanalisation in six of these patients (85.7%). Subarachnoid haemorrhage and large space-occupying bleedings occurred in one (7.1%) and three (21.4%) patients, respectively. At follow-up, three patients (21.4%) were functionally independent, and six (42.9%) had died. Conclusion: When applying different mechanical devices, we found a high recanalisation rate. However, discrepancy between recanalisation and clinical outcome remained. More data are needed to assess the effect of the different methods on the prognoses of stroke patients.« less

  2. Retinal vein occlusion: pathophysiology and treatment options.

    PubMed

    Karia, Niral

    2010-07-30

    This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms.

  3. Clinical outcomes in middle cerebral artery trunk occlusions versus secondary division occlusions after mechanical thrombectomy: pooled analysis of the Mechanical Embolus Removal in Cerebral Ischemia (MERCI) and Multi MERCI trials.

    PubMed

    Shi, Zhong-Song; Loh, Yince; Walker, Gary; Duckwiler, Gary R

    2010-05-01

    The benefit of endovascular revascularization of patients with acute ischemic stroke with middle cerebral artery (MCA) secondary division (M2) occlusions as compared with MCA trunk (M1) occlusions is not known. In this analysis, we compared revascularization status and clinical outcomes in patients with angiographically confirmed MCA M1 versus isolated M2 occlusions treated with mechanical thrombectomy using the Merci Retriever devices. We retrospectively analyzed the pooled data of patients with MCA strokes from the Mechanical Embolus Removal in Cerebral Ischemia (MERCI) and Multi MERCI trials. Patient data were dichotomized into 2 groups: MCA M1 occlusions and isolated M2 occlusions. Baseline characteristics, revascularization rates, hemorrhage rates, complications, outcomes, and mortality were evaluated for both groups. Of 178 patients with MCA occlusion treated in the MERCI and Multi MERCI trials, 84.3% had M1 lesions and 15.7% had isolated M2 lesions. Patients with isolated M2 occlusions were revascularized at a higher rate, required a lower mean number of passes, and were associated with a trend toward shorter mean procedure time than patients with M1 occlusions. No statistically significant differences were found between M2 and M1 groups for symptomatic hemorrhage, clinically significant procedural adverse events, favorable 90-day outcome, or 90-day mortality, although in all instances, the M2 outcomes were numerically better than those in M1 subjects. In multivariate analysis, final revascularization was the strongest independent predictor of good outcome at 90 days. Patients with both MCA M1 occlusions and isolated M2 occlusions can achieve a relatively high rate of revascularization and favorable clinical outcomes after mechanical thrombectomy. In fact, patients with isolated M2 occlusions had a higher rate of revascularization, required fewer passes, and had no increased complications compared with patients with M1 occlusions.

  4. Compliance with the prescribed occlusion treatment for amblyopia.

    PubMed

    Vagge, Aldo; Nelson, Leonard B

    2017-09-01

    The present review article is an update on the current evidence about compliance to the prescribed occlusion treatment for amblyopia. In particular, the authors focus on the predictors and causes of noncompliance and possible interventions to increase it. Compliance with prescribed occlusion treatment is often challenging. Reported rates of compliance range widely from 49% to 87%. Objective monitoring of occlusion has opened up new research opportunities and allow the design of effective therapeutic regimens. Also, predictors and causes of noncompliance have been investigated and their knowledge may help the clinician to improved compliance with prescribed occlusion treatment for amblyopia. Although many of the studies assessing the effectiveness of interventions to increase compliance to patching treatment for amblyopia have many limitations, evidences support that use of educational supports, parents, and patient understanding on the importance of patching and written information should be considered to increase compliance with patching.

  5. Direct current stimulation of titanium interbody fusion devices in primates.

    PubMed

    Cook, Stephen D; Patron, Laura P; Christakis, Petros M; Bailey, Kirk J; Banta, Charles; Glazer, Paul A

    2004-01-01

    The fusion rate for anterior lumbar interbody fusion (ALIF) varies widely with the use of different interbody devices and bone graft options. Adjunctive techniques such as electrical stimulation may improve the rate of bony fusion. To determine if direct current (DC) electrical stimulation of a metallic interbody fusion device enhanced the incidence or extent of anterior bony fusion. ALIF was performed using titanium alloy interbody fusion devices with and without adjunctive DC electrical stimulation in nonhuman primates. ALIF was performed through an anterolateral approach in 35 macaques with autogenous bone graft and either a titanium alloy (Ti-6Al-4V) fusion device or femoral allograft ring. The fusion devices of 19 animals received high (current density 19.6 microA/cm2) or low (current density 5.4 microA/cm2) DC electrical stimulation using an implanted generator for a 12- or 26-week evaluation period. Fusion sites were studied using serial radiographs, computed tomography imaging, nondestructive mechanical testing and qualitative and semiquantitative histology. Fusion was achieved with the titanium fusion device and autogenous bone graft. At 12 weeks, the graft was consolidating and early to moderate bridging callus was observed in and around the device. By 26 weeks, the anterior callus formation was more advanced with increased evidence of bridging trabeculations and early bone remodeling. The callus formation was not as advanced or abundant for the allograft ring group. Histology revealed the spinal fusion device had an 86% incidence of bony fusion at 26 weeks compared with a 50% fusion rate for the allograft rings. DC electrical stimulation of the fusion device had a positive effect on anterior interbody fusion by increasing both the presence and extent of bony fusion in a current density-dependent manner. Adjunctive DC electrical stimulation of the fusion device improved the rate and extent of bony fusion compared with a nonstimulated device. The fusion

  6. Combining technologies: a computerized occlusal analysis system synchronized with a computerized electromyography system.

    PubMed

    Kerstein, Robert B

    2004-04-01

    Current advances in computer technologies have afforded dentists precision ways to examine occlusal contacts and muscle function. Recently, two separate computer technologies have been synchronized together, so that an operator can record their separate diagnostic data simultaneously. The two systems are: the T Scan II Occlusal Analysis System and the Biopak Electromyography Recording System. The simultaneous recording and playback capacity of these two computer systems allows the operator to analyze and correlate specific occlusal moments to specific electromyographic changes that result from these occlusal moments. This synchronization provides unparalleled evidence of the effect occlusal contact arrangement has on muscle function. Therefore, the occlusal condition of an inserted dental prosthesis or the occlusal scheme of the natural teeth (before and after corrective occlusal adjustments) can be readily evaluated, documented, and quantified for both, quality of occlusal parameters and muscle activity and the responses to the quality of the occlusal condition. This article describes their synchronization and illustrates their use in performing precision occlusal adjustment procedures on two patients: one who demonstrates occlusal disharmony while exhibiting the signs and symptoms of chronic myofascial pain dysfunction syndrome, and the other who had extensive restorative work accomplished but exhibits occlusal discomfort post-operatively.

  7. Current voltage perspective of an organic electronic device

    NASA Astrophysics Data System (ADS)

    Mukherjee, Ayash K.; Kumari, Nikita

    2018-05-01

    Nonlinearity in current (I) - voltage (V) measurement is a well-known attribute of two-terminal organic device, irrespective of the geometrical or structural arrangement of the device. Most of the existing theories that are developed for interpretation of I-V data, either focus current-voltage relationship of charge injection mechanism across the electrode-organic material interface or charge transport mechanism through the organic active material. On the contrary, both the mechanisms work in tandem charge conduction through the device. The transport mechanism is further complicated by incoherent scattering from scattering centres/charge traps that are located at the electrode-organic material interface and in the bulk of organic material. In the present communication, a collective expression has been formulated that comprises of all the transport mechanisms that are occurring at various locations of a planar organic device. The model has been fitted to experimental I-V data of Au/P3HT/Au device with excellent degree of agreement. Certain physical parameters such as the effective area of cross-section and resistance due to charge traps have been extracted from the fit.

  8. Retinal vein occlusion: pathophysiology and treatment options

    PubMed Central

    Karia, Niral

    2010-01-01

    This paper reviews the current thinking about retinal vein occlusion. It gives an overview of its pathophysiology and discusses the evidence behind the various established and emerging treatment paradigms. PMID:20689798

  9. Venous Access Devices: Clinical Rounds

    PubMed Central

    Matey, Laurl; Camp-Sorrell, Dawn

    2016-01-01

    Nursing management of venous access devices (VADs) requires knowledge of current evidence, as well as knowledge of when evidence is limited. Do you know which practices we do based on evidence and those that we do based on institutional history or preference? This article will present complex VAD infection and occlusion complications and some of the controversies associated with them. Important strategies for identifying these complications, troubleshooting, and evaluating the evidence related to lack of blood return, malposition, infection, access and maintenance protocols, and scope of practice issues are presented. PMID:28083553

  10. Recent advances in managing vascular occlusions in the cardiac catheterization laboratory

    PubMed Central

    Qureshi, Athar M.; Mullins, Charles E.; Latson, Larry A.

    2018-01-01

    Vascular occlusions continue to be a significant cause of morbidity and mortality. The management of vascular occlusions in patients is complex, requiring specialized expertise in the cardiac catheterization laboratory and from other disciplines. Knowledge of currently available tools at the operator’s disposal is important to optimize the success of these procedures. In this review, we discuss some of the recent advances in recanalization procedures of vascular occlusions and thrombotic lesions in the cardiac catheterization laboratory. PMID:29770200

  11. Initial experience with hysteroscopic tubal occlusion (Essure®)

    PubMed Central

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Lippi, Umberto Gazi; Martins, João Alfredo; Lopes, Reginaldo Guedes Coelho

    2016-01-01

    ABSTRACT Objective To evaluate results of early tubal occlusions performed by hysteroscopy (Essure®). Methods This prospective study included 38 patients, 73.7% of them were white, mean age 34.5 years, they have had on average 3 pregnancies and 2.7 of deliveries. A total of 86.8% of patients previously prepared the endometrium. All procedures were carried out at outpatient unit without anesthesia. Results Insertion rate of the device was 100% at a mean time of 4 minutes and 50 seconds. Based on the analogical visual scale, average pain reported was three, and 55.3% of women did not report pain after the procedure. After 3 months, 89.5% of patients were very satisfied with the method. Simple radiographs of the pelvis showed 92.1% of topical devices, and one case of unilateral expulsion had occurred. A four years follow-up did not show failure in the method. Conclusions Tubal occlusion through hysteroscopy at outpatient unit and without anesthesia was a quickly and well-tolerated procedure. No serious complications were seen, the success rate was high, and patients were satisfied. PMID:27462885

  12. Optimization of the static occlusion by "occlusal surface settling" in the Cerec 3D software.

    PubMed

    Späth, C; Kordass, B

    2006-04-01

    The adjustment of the static occlusion can be automated in computer-based systems. The Cerec 3D software makes it possible to take preformed occlusal surfaces from a database and adapt them to the antagonist. In this adaptation (settling), the CAD occlusal surface "settles" as whole or each cusp individually into the occlusal surface of the antagonist until stable occlusion is reached. Two occlusal surface shapes were compared: Vita Physiodens and Lee Culp. An index was formed from the number, quality, and position of the occlusal contacts for 35 model cases (25 molars, 10 premolars). With regard to the settling of the total occlusal surfaces, there were no differences between the two occlusal surface shapes. In "cusp settling" of the molars, Vita Physiodens performed significantly better. In the comparison of the 1st with the 3rd settling process, significant improvements occurred the 3rd time in many cases when settling individual cusps, but in clearly fewer cases in the settling process of the total occlusal surface. The Lee Culp tooth occlusion improved especially after the 3rd settling process of individual cusps. It is therefore expedient to combine both settling versions with one another.

  13. Incidence and Determinants of Port Occlusions in Cancer Outpatients: A Prospective Cohort Study.

    PubMed

    Milani, Alessandra; Mazzocco, Ketti; Gandini, Sara; Pravettoni, Gabriella; Libutti, Livio; Zencovich, Claudia; Sbriglia, Ada; Pari, Chiara; Magon, Giorgio; Saiani, Luisa

    Normal saline is considered a safe alternative for heparin as a locking solution in totally implantable venous access devices. The incidence rate of partial occlusion with the use of normal saline (easy injection, impossible aspiration) is estimated at 4%. The aim of this study was to investigate determinants of partial occlusions with the use of normal saline solution and the maintenance of positive pressure in the catheter. We enrolled 218 patients with different solid tumors who underwent pharmacologic treatment through the port with different frequencies: from once every week to at least once every month. The port was flushed with normal saline solution keeping a positive pressure in the catheter. We performed 4111 observations and documented normal port functioning in 99% of observations (n = 4057) and partial occlusions in 1% of observations (n = 54). Partial occlusions were significantly associated with frequency of port flushing (P < .05), chemotherapy (P < .001), and blood sample collection (P < .001). The use of positive pressure in addition to normal saline reduces the incidence rate of partial occlusions. The type of treatment, blood sample collection, and treatment schedule are important determinants of partial occlusions. Nurses play a key role in maintaining a functioning port using positive pressure during the flushing techniques. Certain risk factors must be monitored to prevent partial occlusions, and certain patients are more likely to present with port-related problems.

  14. Comparative mRNA and MicroRNA Profiling during Acute Myocardial Infarction Induced by Coronary Occlusion and Ablation Radio-Frequency Currents

    PubMed Central

    Santana, Eduardo T.; Feliciano, Regiane dos Santos; Serra, Andrey J.; Brigidio, Eduardo; Antonio, Ednei L.; Tucci, Paulo J. F.; Nathanson, Lubov; Morris, Mariana; Silva, José A.

    2016-01-01

    The ligation of the left anterior descending coronary artery is the most commonly used experimental model to induce myocardial infarction (MI) in rodents. A high mortality in the acute phase and the heterogeneity of the size of the MI obtained are drawbacks recognized in this model. In an attempt to solve the problem, our group recently developed a new MI experimental model which is based on application of myocardial ablation radio-frequency currents (AB-RF) that yielded MI with homogeneous sizes and significantly reduce acute mortality. In addition, cardiac structural, and functional changes aroused by AB-RF were similar to those seen in animals with MI induced by coronary artery ligation. Herein, we compared mRNA expression of genes that govern post-MI milieu in occlusion and ablation models. We analyzed 48 mRNAs expressions of nine different signal transduction pathways (cell survival and metabolism signs, matrix extracellular, cell cycle, oxidative stress, apoptosis, calcium signaling, hypertrophy markers, angiogenesis, and inflammation) in rat left ventricle 1 week after MI generated by both coronary occlusion and AB-RF. Furthermore, high-throughput miRNA analysis was also assessed in both MI procedures. Interestingly, mRNA expression levels and miRNA expressions showed strong similarities between both models after MI, with few specificities in each model, activating similar signal transduction pathways. To our knowledge, this is the first comparison of genomic alterations of mRNA and miRNA contents after two different MI procedures and identifies key signaling regulators modulating the pathophysiology of these two models that might culminate in heart failure. Furthermore, these analyses may contribute with the current knowledge concerning transcriptional and post-transcriptional changes of AB-RF protocol, arising as an alternative and effective MI method that reproduces most changes seem in coronary occlusion. PMID:27932994

  15. Development of induction current acquisition device based on ARM

    NASA Astrophysics Data System (ADS)

    Ji, Yanju; Liu, Xiyang; Huang, Wanyu; Yao, Jiang; Yuan, Guiyang; Hui, Luan; Guan, Shanshan

    2018-03-01

    We design an induction current acquisition device based on ARM in order to realize high resolution and high sampling rate of acquisition for the induction current in wire-loop. Considering its characteristics of fast attenuation and small signal amplitude, we use the method of multi-path fusion for noise suppression. In the paper, the design is carried out from three aspects of analog circuit and device selection, independent power supply structure and the electromagnetic interference suppression of high frequency. DMA and ping-pong buffer, as a new data transmission technology, solves real time storage problem of massive data. The performance parameters of ARM acquisition device are tested. The comparison test of ARM acquisition device and cRIO acquisition device is performed at different time constants. The results show that it has 120dB dynamic range, 47kHz bandwidth, 96kHz sampling rate, 5μV the smallest resolution, and its average error value is not more than 4%, which proves the high accuracy and stability of the device.

  16. Results of a customer-based, post-market surveillance survey of the HeRO access device.

    PubMed

    Fusselman, Maureen

    2010-08-01

    In order to supplement post-market surveillance data on the HeRO vascular access device, a non-scientific customer survey was conducted to obtain quantitative data from dialysis providers caring for patients implanted with the device. Dialysis nurses involved in the care of HeRO patients were contacted in order to obtain post-implant device performance information for 10% of patients implanted with the device at the time of the survey. Thirty-eight dialysis units with a total of 65 HeRO patients participated in the survey. The total duration of HeRO device use was 348.4 months with an average use of 5.4 months. Thirty-eight of the 65 HeRO patients (58.5%) were reported to not have experienced any performance issues. There were 28 device performance incidents reported for the remaining 27 patients included in the survey. Occlusion was the single most commonly reported device-related performance issue with 18 patients (27.7%) experiencing 25 occlusive episodes. The majority of the patients who had an occlusion (66.7%) only experienced one occlusive event. Infections occurred in 4 patients (6.2%) with an overall infection rate of 0.38 per 1,000 patient days. Post-market clinical experience during the first 18 months of commercialization of the HeRO device were in line with expectations based on the results from initial clinical studies with the device. Device occlusion remains the most commonly reported performance issue with the reported rate in this survey less than that which was reported in earlier published studies with the device.

  17. Feasibility and Safety of Distal and Proximal Combined Endovascular Approach with a Balloon-Guiding Catheter for Subclavian Artery Total Occlusion.

    PubMed

    Yamamoto, Taiki; Ohshima, Tomotaka; Ishikawa, Kojiro; Goto, Shunsaku; Tamari, Yosuke

    2017-04-01

    Symptomatic subclavian artery total occlusion is widely treated with an endovascular procedure that often results in distal vertebral artery embolism. Therefore, protection devices are important. Establishing a filter or balloon device in the vertebral artery can protect against this distal embolism. However, the use of embolic protection devices is not easy, and it makes the procedure more complicated. Here, we report a case of symptomatic subclavian artery total occlusion that was treated successfully with a balloon-guiding catheter and the pull-through technique. A 67-year-old man developed intermittent motor weakness in his left arm. Aortic angiography demonstrated a complete occlusion of the left proximal subclavian artery and a retrograde flow through the left vertebral artery to the distal brachial artery. In this case, we used a balloon-guiding catheter and the pull-through technique to prevent distal embolism. The balloon-guiding system was useful not only for embolic protection but also for scaffold during excavation and for the centering effect against invisible vessels. The pull-through technique enabled our devices to deliver easily and smoothly. The patient was treated successfully without complications. The distal and proximal combined endovascular treatment with a transbrachial balloon-guiding catheter is a beneficial treatment option for patients with subclavian artery total occlusion. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Direct observation of mineral–organic composite formation reveals occlusion mechanism

    DOE PAGES

    Cho, Kang Rae; Kim, Yi -Yeoun; Yang, Pengcheng; ...

    2016-01-06

    Manipulation of inorganic materials with organic macromolecules enables organisms to create biominerals such as bones and seashells, where occlusion of biomacromolecules within individual crystals generates superior mechanical properties. Current understanding of this process largely comes from studying the entrapment of micron-size particles in cooling melts. Here, by investigating micelle incorporation in calcite with atomic force microscopy and micromechanical simulations, we show that different mechanisms govern nanoscale occlusion. By simultaneously visualizing the micelles and propagating step edges, we demonstrate that the micelles experience significant compression during occlusion, which is accompanied by cavity formation. This generates local lattice strain, leading to enhancedmore » mechanical properties. Furthermore, these results give new insight into the formation of occlusions in natural and synthetic crystals, and will facilitate the synthesis of multifunctional nanocomposite crystals.« less

  19. Effect of occlusal vertical dimension on lip positions at smile.

    PubMed

    Chou, Jang-Ching; Thompson, Geoffrey A; Aggarwal, Harshit A; Bosio, Jose A; Irelan, Jon P

    2014-09-01

    In complete mouth reconstructive dentistry, the occlusal vertical dimension may be increased to provide adequate restorative space or to improve esthetics. The effect of increasing the occlusal vertical dimension on the smile is not well understood. The purpose of this study was to evaluate the effect of increasing the occlusal vertical dimension on the dimensions of the smile. Thirty dental students, 12 men and 18 women between the ages of 21 and 30 years old, participated in this study. Polyvinyl siloxane occlusal registrations 2, 4, 6, and 8 mm in thickness were fabricated from articulated stone casts. Posed smile images at occlusal vertical dimension +0, +2, +4, +6, and +8 mm were made with a digital single lens reflex camera mounted on a tripod. A wall-mounted head-positioning device, modified from a cephalometric unit, was used to stabilize the head position. Interlabial gap height, intercommissural width, incisal edge to upper lip, and incisal edge-to-lower lip measurements were made with computer software. The smile index was obtained by dividing width by height. The display zone area was measured by using computer software tracing. One-way repeated measures ANOVA (α=.05) was used for statistical analysis. With an increase in the occlusal vertical dimension, the interlabial gap height, incisal edge to lower lip distance, and display zone area increased significantly (P<.001), whereas the smile index decreased significantly (P<.001). No significant changes were observed in the intercommissural width and incisal edge to upper lip distance. The interlabial gap height, incisal edge-to-lower lip distance, and display zone area increase with increased occlusal vertical dimension. The smile index decreases with increased occlusal vertical dimension. However, the width of the smile and the length of the upper lip tend to remain unchanged. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights

  20. 77 FR 61768 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-11

    ... vasculature via partial occlusion of the descending aorta, including in patients with acute ischemic stroke... device is placed in the descending aorta. On March 30, 2005, a Humanitarian Device Exemption application... selectively stopping or controlling flow in the peripheral vasculature, which includes the descending aorta...

  1. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms.

    PubMed

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-12-01

    The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as "decreased," "slightly decreased," and "preserved". Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P<0.001) between the two groups. HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group (33.8 ± 8.2 HU vs. 11.9 ± 6.1 HU, P<0.001). There was no significant difference in HUs for the entire lesion between the non-occlusive (33.8 ± 8.2 HU) and corresponding normal group (34.5 ± 6.8 HU; P=0.294). Iodine perfusion tended to be visually and quantitatively preserved in lungs with

  2. [Occlusion and posture: is there evidence of correlation?].

    PubMed

    Michelotti, A; Manzo, P; Farella, M; Martina, R

    1999-11-01

    The observation that the masticatory system and the postural body regulating system are anatomically and functionally related, has led to postulate several hypotheses of correlation between occlusal and postural disturbances. In the last decade, these arguments have gained a great social impact, also because they have been broadly spread by the mass-media. As a consequence, there has been a growing number of patients seeking concomitant occlusal and postural treatments. The aim of this study was to review critically the current evidence of correlation between the two systems; this in order to address clinical issues for the management of patients. Methodology of the studies reviewed has been evaluated according to the criteria suggested by Storey and Rugh 20 rif. Although there are some evidences of correlation between occlusion and posture, this appears limited to the cranio-cervical tract of the column and tends to disappear when descending in cranio-caudal direction. On the basis of this review of the literature, it's not advisable to treat postural imbalance by means of occlusal treatment or vice versa, particularly if the therapeutic modalities are irreversible.

  3. Dark current of organic heterostructure devices with insulating spacer layers

    NASA Astrophysics Data System (ADS)

    Yin, Sun; Nie, Wanyi; Mohite, Aditya D.; Saxena, Avadh; Smith, Darryl L.; Ruden, P. Paul

    2015-03-01

    The dark current density at fixed voltage bias in donor/acceptor organic planar heterostructure devices can either increase or decrease when an insulating spacer layer is added between the donor and acceptor layers. The dominant current flow process in these systems involves the formation and subsequent recombination of an interfacial exciplex state. If the exciplex formation rate limits current flow, the insulating interface layer can increase dark current whereas, if the exciplex recombination rate limits current flow, the insulating interface layer decreases dark current. We present a device model to describe this behavior and illustrate it experimentally for various donor/acceptor systems, e.g. P3HT/LiF/C60.

  4. Contemporary treatment of patients with chronic total occlusion: critical appraisal of different state-of-the-art techniques and devices.

    PubMed

    García-García, Héctor M; Kukreja, Neville; Daemen, Joost; Tanimoto, Shuzou; van Mieghem, Carlos; Gonzalo, Nieves; van Weenen, Sander; van der Ent, Martin; Sianos, Georgios; de Feyter, Pim; Serruys, Patrick W

    2007-08-01

    To describe the contemporary approach of chronic total occlusion (CTO) treatment of patients at the Thoraxcenter, Rotterdam, The Netherlands. Additionally, to make a critical appraisal of the performance of state-of-the-art CTO dedicated guidewires and devices in a prospective registry of patients. During 20 months, a total of 160 consecutive patients (165 CTOs) were enrolled. The mean age was 61.5+/-11.1 years and 83.6% were male. In 91.5% of the patients this was the first attempt to open the CTO and 93.8% were de novo. The overall success rate was 60.6%. A median of 1 guiding catheter was used per case (Range: 1 to 9) and a median of 4 guidewires (Range: 1 to 11; 13 different types). 74.5% patients required more than one guidewire/device for the treatment of the CTO. The guidewires that most frequently crossed the CTO were the following: PT Graphix intermediate 33.0%, Miracle 3 g 27.4% and Crosswire NT 25.5%. The only device tested as a first option for the treatment of the CTOs was the CROSSER. Overall, the CROSSER system was used in 23 (13.9%) patients with a success rate of 60.9%. The Point 9(R) X-80 Laser catheter was used in 10 (6.1%) patients with a success rate of 60%. Another 3 patients were treated with the Point 7(R) laser catheter. Both were used either to facilitate the crossing of the balloon, or to treat primarily in-stent restenosis occlusions. The SafeCross(R) System was used in 15 (9.1%) patients and the success rate in these patients was 46.7%. The most common strategy used in this registry was the use of an over-the-wire balloon in 81.5% of the cases. The parallel wire technique was used in 27.3% of the cases and in 12.7% was converted into a "see-saw" technique. When a large false lumen was created, re-entry into the true lumen was attempted in 21.2% of the cases, by means of IVUS guided approach and/or the use of stiffer guidewires, such as a Confianza guidewire. Retrograde recanalisation was attempted in 10 cases (6.1%), in three cases a

  5. Effect of occlusion amblyopia after prescribed full-time occlusion on long-term visual acuity outcomes.

    PubMed

    Longmuir, Susannah; Pfeifer, Wanda; Scott, William; Olson, Richard

    2013-01-01

    To investigate the incidence and characteristics of occlusion amblyopia with prescribed full-time patching and determine its effect on long-term visual acuity outcomes. The records of patients younger than 10 years diagnosed as having amblyopia between 1970 and 2000 were retrospectively reviewed. Patients were prescribed full-time occlusion and observed until completion of therapy. Of 597 patients treated for amblyopia by full-time patching, 115 were diagnosed as having occlusion amblyopia (19.3%). Seventy-five percent (86 of 115) developed occlusion amblyopia during the first episode of full-time patching. Occlusion amblyopia occurred more frequently in children prescribed full-time patching at an earlier age (P = .0002), with an odds ratio of 8.56 (95% confidence interval: 2.73, 26.84) in children younger than 36 months and 2.66 (95% confidence interval: 0.96, 7.37) in children between 36 and 59 months old. Seven of the patients with occlusion amblyopia did not reverse fixation and continued to fixate with the initially amblyopic eye after treatment. Final visual acuity in these eyes with occlusion amblyopia was 20/30 or better. After cessation of treatment, the final interocular difference in visual acuity was less in patients with a history of occlusion amblyopia (P = .003). Occlusion amblyopia occurred at all ages, but the incidence decreased with increasing age. Patients who developed occlusion amblyopia with prescribed full-time occlusion had less interocular visual acuity difference than patients who did not, suggesting that development of occlusion amblyopia can indicate the potential for the development of better vision in the originally amblyopic eye. Copyright 2013, SLACK Incorporated.

  6. First in vivo evaluation of a flexible self-apposing left atrial appendage closure device in the canine model.

    PubMed

    Cheng, Yanping; Conditt, Gerard; Yi, Genghua; Tellez, Armando; Corcoran, Michael; Rousselle, Serge; Kaluza, Greg L; Granada, Juan F

    2015-07-01

    Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events. © 2015 Wiley Periodicals, Inc.

  7. Initial experience of coiling cerebral aneurysms using the new Comaneci device

    PubMed Central

    Lawson, Aimee Louise Deborah; Chandran, Arun; Puthuran, Mani; Goddard, Tony; Nahser, Hans; Patankar, Tufail

    2015-01-01

    We present our initial patient experience with an innovative temporary bridging device, the Comaneci (Rapid Medical, Israel), to assist in the coiling of cerebral aneurysms. The Comaneci device confers the same benefits as balloon remodeling but without the risks of parent artery occlusion. This alleviates time pressure on the clinician, and could reduce the risk of parent artery thrombosis. Three patients were treated with the Comaneci device. Two patients had acute ruptured posterior communicating aneurysms and one patient was treated electively for a carotico-ophthalmic aneurysm. Excellent occlusion of all three aneurysms was obtained. One patient developed a distal middle cerebral artery clot, that was treated with intravenous aspirin, with minor neurological consequences. These early results show that the Comaneci device can be used to achieve good cerebral aneurysm occlusion. Vessel patency is maintained throughout the procedure with potential advantages over conventional balloon assisted coiling. PMID:26123460

  8. Challenges and Recent Developments in Hearing Aids: Part II. Feedback and Occlusion Effect Reduction Strategies, Laser Shell Manufacturing Processes, and Other Signal Processing Technologies

    PubMed Central

    Chung, King

    2004-01-01

    This is the second part of a review on the challenges and recent developments in hearing aids. Feedback and the occlusion effect pose great challenges in hearing aid design and usage. Yet, conventional solutions to feedback and the occlusion effect often create a dilemma: the solution to one often leads to the other. This review discusses the advanced signal processing strategies to reduce feedback and some new approaches to reduce the occlusion effect. Specifically, the causes of three types of feedback (acoustic, mechanical, and electromagnetic) are discussed. The strategies currently used to reduce acoustic feedback (i.e., adaptive feedback reduction algorithms using adaptive gain reduction, notch filtering, and phase cancellation strategies) and the design of new receivers that are built to reduce mechanical and electromagnetic feedback are explained. In addition, various new strategies (i.e., redesigned sound delivery devices and receiver-in-the-ear-canal hearing aid configuration) to reduce the occlusion effect are reviewed. Many manufacturers have recently adopted laser shell-manufacturing technologies to overcome problems associated with manufacturing custom hearing aid shells. The mechanisms of selected laser sintering and stereo lithographic apparatus and the properties of custom shells produced by these two processes are reviewed. Further, various new developments in hearing aid transducers, telecoils, channel-free amplification, open-platform programming options, rechargeable hearing aids, ear-level frequency modulated (FM) receivers, wireless Bluetooth FM systems, and wireless programming options are briefly explained and discussed. Finally, the applications of advanced hearing aid technologies to enhance other devices such as cochlear implants, hearing protectors, and cellular phones are discussed. PMID:15735871

  9. Evidence of an application of a variable MEMS capacitive sensor for detecting shunt occlusions

    NASA Astrophysics Data System (ADS)

    Apigo, David J.; Bartholomew, Philip L.; Russell, Thomas; Kanwal, Alokik; Farrow, Reginald C.; Thomas, Gordon A.

    2017-04-01

    A sensor was tested subdural and in vitro, simulating a supine infant with a ventricular-peritoneal shunt and controlled occlusions. The variable MEMS capacitive device is able to detect and forecast blockages, similar to early detection procedures in cancer patients. For example, with gradual occlusion development over a year, the method forecasts a danger over one month ahead of blockage. The method also distinguishes between ventricular and peritoneal occlusions. Because the sensor provides quantitative data on the dynamics of the cerebrospinal fluid, it can help test new therapies and work toward understanding hydrocephalus as well as idiopathic normal pressure hydrocephalus. The sensor appears to be a substantial advance in treating brain injuries treated with shunts and has the potential to bring significant impact in a clinical setting.

  10. Recent Advances in Alternating Current-Driven Organic Light-Emitting Devices.

    PubMed

    Pan, Yufeng; Xia, Yingdong; Zhang, Haijuan; Qiu, Jian; Zheng, Yiting; Chen, Yonghua; Huang, Wei

    2017-11-01

    Organic light-emitting devices (OLEDs), typically operated with constant-voltage or direct-current (DC) power sources, are candidates for next-generation solid-state lighting and displays, as they are light, thin, inexpensive, and flexible. However, researchers have focused mainly on the device itself (e.g., development of novel materials, design of the device structure, and optical outcoupling engineering), and little attention has been paid to the driving mode. Recently, an alternative concept to DC-driven OLEDs by directly driving devices using time-dependent voltages or alternating current (AC) has been explored. Here, the effects of different device structures of AC-driven OLEDs, for example, double-insulation, single-insulation, double-injection, and tandem structure, on the device performance are systematically investigated. The formation of excitons and the dielectric layer, which are important to achieve high-performance AC-driven OLEDs, are carefully considered. The importance of gaining further understanding of the fundamental properties of AC-driven OLEDs is then discussed, especially as they relate to device physics. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Numeric simulation of occlusal interferences in molars restored with ultrathin occlusal veneers.

    PubMed

    Magne, Pascal; Cheung, Raymond

    2017-01-01

    Selecting material for a minimally invasive occlusal veneer reconstruction concept requires an understanding of how stresses are distributed during functional and parafunctional forces. The purpose of this in vitro study was to investigate stress distribution in a maxillary molar restored with ultrathin occlusal veneers and subjected by an antagonistic mandibular molar to clenching and working and nonworking movements. A maxillary first molar was modeled from microcomputed tomography (micro-CT) data, using medical image processing software, stereolithography editing/optimizing software, and finite element software. Simulated ultrathin occlusal veneer materials were used. The mandibular molar antagonist was a solid nondeformable geometric entity. Loads simulated clenching, working, and nonworking movements with loading of 500 N. The values of the maximum principal stress were recorded. In the clenching load situation, maximum tensile stresses were located at the occlusal veneer (52 MPa for composite resin versus 47 MPa for ceramic). In the working movement, significant additional tensile stresses were found on the palatal root (87 MPa for composite resin and 85 MPa for ceramic). In the nonworking movement, tensile stress on the ultrathin occlusal veneer increased to 118 MPa for composite resin and 143 MPa for ceramic veneers. Tensile stress peaks shifted to the mesiobuccal root (75 MPa for composite resin and 74 MPa for ceramic). The topography of stresses generated by the various occlusal interferences were clearly identified. Significant tensile stress concentrations were found within the restoration's occlusal topography and root, with the nonworking interference being the most harmful and also the most revealing of the difference between the composite resin and ceramic ultrathin occlusal veneers. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Haptic simulation framework for determining virtual dental occlusion.

    PubMed

    Wu, Wen; Chen, Hui; Cen, Yuhai; Hong, Yang; Khambay, Balvinder; Heng, Pheng Ann

    2017-04-01

    The surgical treatment of many dentofacial deformities is often complex due to its three-dimensional nature. To determine the dental occlusion in the most stable position is essential for the success of the treatment. Computer-aided virtual planning on individualized patient-specific 3D model can help formulate the surgical plan and predict the surgical change. However, in current computer-aided planning systems, it is not possible to determine the dental occlusion of the digital models in the intuitive way during virtual surgical planning because of absence of haptic feedback. In this paper, a physically based haptic simulation framework is proposed, which can provide surgeons with the intuitive haptic feedback to determine the dental occlusion of the digital models in their most stable position. To provide the physically realistic force feedback when the dental models contact each other during the searching process, the contact model is proposed to describe the dynamic and collision properties of the dental models during the alignment. The simulated impulse/contact-based forces are integrated into the unified simulation framework. A validation study has been conducted on fifteen sets of virtual dental models chosen at random and covering a wide range of the dental relationships found clinically. The dental occlusions obtained by an expert were employed as a benchmark to compare the virtual occlusion results. The mean translational and angular deviations of the virtual occlusion results from the benchmark were small. The experimental results show the validity of our method. The simulated forces can provide valuable insights to determine the virtual dental occlusion. The findings of this work and the validation of proposed concept lead the way for full virtual surgical planning on patient-specific virtual models allowing fully customized treatment plans for the surgical correction of dentofacial deformities.

  13. Differences between Subjective Balanced Occlusion and Measurements Reported With T-Scan III

    PubMed Central

    Lila-Krasniqi, Zana; Shala, Kujtim; Krasniqi, Teuta Pustina; Bicaj, Teuta; Ahmedi, Enis; Dula, Linda; Dragusha, Arlinda Tmava; Guguvcevski, Ljuben

    2017-01-01

    BACKGROUND: The aetiology of Temporomandibular disorder is multifactorial, and numerous studies have addressed that occlusion may be of great importance in the pathogenesis of Temporomandibular disorder. AIM: The aim of this study is to determine if any direct relationship exists between balanced occlusion and Temporomandibular disorder and to evaluate the differences between subjective balanced occlusion and measurements reported with T-scan III electronic system. MATERIAL AND METHODS: A total of 54 subjects were divided into three groups, selection based on anamnesis-responded to a Fonseca questionnaire and clinical measurements analysed with electronic system T-scan III. In the I study group were participants with fixed dentures with prosthetic ceramic restorations. In the II study group were symptomatic participants with TMD. In the third control group were healthy participants with full arch dentition that completed a subjective questionnaire that documented the absence of jaw pain, joint noise, locking and subjects without a history of TMD. The occlusal balance was reported subjectively through Fonseca questionnaire and compared with occlusion analysed with electronic system T-scan III. RESULTS: For attributive data were used percentage of the structure. Differences in P < 0.05 were considered significant. After distributing attributive data of occlusal balance subjectively reported and compared with measurements analysed with electronic system T-scan III were found significant difference P < 0.001 in all three groups. CONCLUSION: In our study, it was concluded that there were statistically significant differences of balanced occlusion in all three groups. Also it was concluded that subjective data are not exact with measurements reported with electronic device T-scan III. PMID:28932311

  14. Voxel-Space Ambient Occlusion

    DTIC Science & Technology

    2012-02-01

    a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. a...represents the BRDF of the surface material, for incoming direction ψ and an outgoing direction. L(y) is the incoming radiance in the direction ψ from a...10-1-0338). Models come from the Stanford repository. References [BS09] L. Bavoil, M.Sainz Multi-layer dual-resolution screen-space ambient occlusion

  15. Recanalization of acute carotid stent occlusion using Penumbra 4Max aspiration catheter: technical report and review of rescue strategies for acute carotid stent occlusion.

    PubMed

    Munich, Stephan; Moftakhar, Roham; Lopes, Demetrius

    2014-10-01

    Carotid artery stenting (CAS) has become a widely used treatment for carotid artery stenosis, especially in high-risk patients. Acute in-stent and distal protection device occlusion are potentially catastrophic complications of this procedure. Previously described rescue strategies have included administration of antiplatelet agents (eg, abciximab) with/without thrombolytics and removal of the filter. Here we describe the successful resolution of in-stent occlusion by mechanical thrombolysis using the Penumbra 4Max aspiration catheter. Distal flow was subsequently restored with minimal residual stenosis. The patient did not suffer any consequent neurological deficits. The different strategies that could be used in this critical situation are reviewed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Short-Wavelength Light-Emitting Devices With Enhanced Hole Injection Currents

    DTIC Science & Technology

    2005-05-01

    hot-hole injector with appreciably enhancement of the injection current is proposed and developed to be integrated with commonly used vertical...structures of the emitting devices. Second, we develop the alternative design of UV-light sources on the base of lateral p+ - i - n+ superlattice structures...enhancement of the injection current is proposed and developed to be integrated with commonly used vertical structures of the emitting devices. Second

  17. Acute Central Retinal Vein Occlusion Secondary to Reactive Thrombocytosis after Splenectomy

    PubMed Central

    Oncel Acir, Nursen; Borazan, Mehmet

    2014-01-01

    The diagnosis and treatment of central retinal vein occlusion was reported in a young patient. Central retinal vein occlusion was probably related to secondary to reactive thrombocytosis after splenectomy. The patient was treated with steroids for papilledema and administered coumadin and aspirin. The symptoms resolved, and the findings returned to normal within three weeks. Current paper emphasizes that, besides other well-known thrombotic events, reactive thrombocytosis after splenectomy may cause central retinal vein occlusion, which may be the principal symptom of this risky complication. Thus, it can be concluded that followup for thrombocytosis and antithrombotic treatment, when necessary, are essential for these cases. PMID:25276452

  18. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    PubMed

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  19. Contralateral Occlusion Test: The effect of external ear canal occlusion on hearing thresholds.

    PubMed

    Reis, Luis Roque; Fernandes, Paulo; Escada, Pedro

    Bedside testing with tuning forks may decrease turnaround time and improve decision making for a quick qualitative assessment of hearing loss. The purpose of this study was to quantify the effects of ear canal occlusion on hearing, in order to decide which tuning fork frequency is more appropriate to use for quantifying hearing loss with the Contralateral Occlusion Test. Twenty normal-hearing adults (forty ears) underwent sound field pure tone audiometry with and without ear canal occlusion. Each ear was tested with the standard frequencies. The contralateral ear was suppressed with by masking. Ear occlusion was performed by two examiners. Participants aged between 21 and 30 years (25.6±3.03 years) showed an increase in hearing thresholds with increasing frequencies from 19.94dB (250Hz) to 39.25dB (2000Hz). The threshold difference between occluded and unoccluded conditions was statistically significant and increased from 10.69dB (250Hz) to 32.12dB (2000Hz). There were no statistically significant differences according to gender or between the examiners. The occlusion effect increased the hearing thresholds and became more evident with higher frequencies. The occlusion method as performed demonstrated reproducibility. In the Contralateral Occlusion Test, 256Hz or 512Hz tuning forks should be used for diagnosis of mild hearing loss, and a 2048Hz tuning fork should be used for moderate hearing loss. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  20. Radiological assessment of placement of the hysteroscopically inserted Essure permanent birth control device.

    PubMed

    Lorente Ramos, R M; Azpeitia Armán, J; Aparicio Rodríguez-Miñón, P; Salazar Arquero, F J; Albillos Merino, J C

    2015-01-01

    Essure is a permanent birth control device that is inserted through the cervix by hysteroscopy. The device is placed in the fallopian tubes, where it causes occlusion by stimulating fibrosis. Patients can be followed up with plain-film X-rays, hysterosalpingography, and ultrasonography, although the devices can also be identified incidentally on CT and MRI. The follow-up of Essure is based on checking the criteria for appropriate positioning and correct functioning (tubal occlusion) and on diagnosing complications. The most common complications are perforation, migration (toward the uterine or peritoneal cavity), and occlusion failure. In hysterosalpingography, vascular intravasation is the most common cause of diagnostic error. Radiologists need to know how to recognize the device on different imaging techniques, how to check that it is correctly placed and functioning, and how to diagnose complications. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  1. [A rare trauma-associated cause of central retinal vein occlusion in a young subject].

    PubMed

    Mouinga Abayi, D A; Giraud, J-M; Fenolland, J-R; El Asri, F; Sendon, D; May, F; Renard, J-P

    2012-06-01

    Retinal vein occlusions are the second leading cause of retinal vascular disease, after diabetic retinopathy. In the case of young subjects, a thorough etiological investigation must be conducted in order to diagnose rare etiologies, such as this heterozygous mutation of the factor II gene associated with a central retinal vein occlusion (CRVO), occurring in a young subject within the context of trauma. The case deals with a 35-year-old soldier on a mission in a conflict zone. He was the victim of blast injury as a result of the explosion of an improvised explosive device (IED) or homemade bomb, and presented a sudden decline in visual acuity in his left eye associated with the clinical picture of a CRVO. Analysis showed a heterozygous factor II G20210A gene mutation. Retinal vein occlusions are always serious visual events. In the case of young subjects, a thorough etiological investigation must be conducted in search of rare abnormalities likely to lead to retinal vein occlusion. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  2. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    PubMed

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  3. Acute stroke with major intracranial vessel occlusion: Characteristics of cardioembolism and atherosclerosis-related in situ stenosis/occlusion.

    PubMed

    Horie, Nobutaka; Tateishi, Yohei; Morikawa, Minoru; Morofuji, Yoichi; Hayashi, Kentaro; Izumo, Tsuyoshi; Tsujino, Akira; Nagata, Izumi; Matsuo, Takayuki

    2016-10-01

    Acute ischemic stroke with major intracranial vessel occlusion is commonly due to cardioembolic or atherosclerosis-related in situ stenosis/occlusion, and immediate identification of these subtypes is important to establish the optimal treatment strategy. The aim of this study was to clarify the differences in clinical presentation, radiological findings, neurological temporal courses, and outcomes between these etiologies, which have not been fully evaluated. Consecutive emergency patients with acute ischemic stroke were retrospectively reviewed. Among them, patients with stroke with major intracranial vessel occlusion were analyzed with a focus on clinical and radiological findings, and a comparison was performed for those with cardioembolic or atherosclerosis-related in situ stenosis/occlusion. Of 1053 patients, 80 had stroke with acute major intracranial vessel occlusion (45 with cardioembolic and 35 with atherosclerosis-related in situ stenosis/occlusion). Interestingly, the susceptibility vessel sign (SVS) on T2-weighted MR angiography was more frequently detected in cardioembolic stroke (80.0%) than in atherosclerosis (in situ stenosis: 5.9%, chronic occlusion: 14.3%). Moreover, the proximal intra-arterial signal (IAS) on arterial spin labeling MRI and the distal IAS on fluid attenuated inversion recovery MRI was less frequently detected in chronic occlusion (27.3% and 50.0%, respectively) than in acute occlusion due to cardioembolic or in situ stenosis. Multivariate regression analysis showed that the SVS was significantly related to cardioembolism (adjusted odds ratio (OR): 21.68, P=0.004). Clinical characteristics of acute stroke with major intracranial vessel occlusion differ depending on the etiology. The SVS and proximal/distal IAS on MRI are useful to distinguish between cardioembolic and atherosclerotic-related in situ stenosis/occlusion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. A study on measuring occlusal contact area using silicone impression materials: an application of this method to the bite force measurement system using the pressure-sensitive sheet.

    PubMed

    Ando, Katsuya; Kurosawa, Masahiro; Fuwa, Yuji; Kondo, Takamasa; Goto, Shigemi

    2007-11-01

    The aim of this study was to establish an objective and quantitative method of measuring occlusal contact areas. To this end, bite records were taken with a silicone impression material and a light transmission device was used to read the silicone impression material. To examine the effectiveness of this novel method, the occlusal contact area of the silicone impression material and its thickness limit of readable range were measured. Results of this study suggested that easy and highly accurate measurements of occlusal contact area could be obtained by selecting an optimal applied voltage of the light transmission device and an appropriate color of the silicone impression material.

  5. Recurrence of amblyopia after occlusion therapy.

    PubMed

    Bhola, Rahul; Keech, Ronald V; Kutschke, Pamela; Pfeifer, Wanda; Scott, William E

    2006-11-01

    To determine the stability of visual acuity (VA) after a standardized occlusion regimen in children with strabismic and/or anisometropic amblyopia. Retrospective, population-based, consecutive observational case series. Four hundred forty-nine patients younger than 10 years who underwent an occlusion trial for amblyopia and were observed until there was a recurrence of amblyopia or for a maximum of 1 year after decrease or cessation of occlusion therapy. We performed a retrospective chart review of all patients treated by occlusion therapy for strabismic and/or anisometropic amblyopia at our institution over a 34-year period. Of the 1621 patients identified in our database, 449 met the eligibility criteria and were included in this study. Patients having at least a 2 logarithm of the minimum angle of resolution (logMAR)-level improvement in VA by optotypes or a change from unmaintained to maintained fixation preference during the course of occlusion therapy were included. A recurrence of amblyopia was defined as > or =2 logMAR levels of VA reduction or reversal of fixation preference within 1 year after a decrease or cessation of occlusion therapy. Recurrence of amblyopia after a decrease or cessation of occlusion therapy and its relationship with patient age and VA of the amblyopic eye at the time of decrease or cessation of occlusion therapy. Of 653 occlusion trials, 179 (27%) resulted in recurrence of amblyopia. The recurrence was found to be inversely correlated with patient age. There was no statistically significant association between the recurrence of amblyopia and VA of the amblyopic eye at the end of maximal occlusion therapy. There is a clinically important risk of amblyopia recurrence when occlusion therapy is decreased before the age of 10 years. The risk of recurrence is inversely correlated with age (P<0.0001).

  6. Dental occlusion ties: A rapid, safe, and non‐invasive maxillo‐mandibular fixation technology

    PubMed Central

    2017-01-01

    Objectives For decades, Erich arch bars have been a standard in establishing maxillo‐mandibular fixation (MMF). While reliable, the approach risks sharps injury, consumes operating room time, and inflicts gingival trauma. Newer technologies including screw‐based techniques and “hybrid” techniques have improved MMF by reducing sharps injuries and operating room time, but risk injury to tooth roots, nerves, and gingiva. This study aims to establish the application, strengths, and limitations of dental occlusion ties as a novel alternative in maxillo‐mandibular fixation. Study Design Prospective, non‐blinded, human feasibility clinical trial. Materials and Methods An iterative prototyping process was used to invent dental occlusion ties (brand name: Minne Ties). Development included 3D printing, cadaver prototype testing, human apical embrasure measurement, and ultimately non‐significant risk human clinical trial testing. In the IRB‐approved feasibility clinical trial, the devices were applied to mandible and maxilla fracture candidates with fractures amenable to intra‐operative MMF with open reduction with internal fixation. The ties were removed prior to extubation. Pre‐teens, comminuted fracture patients, and patients requiring post‐operative MMF were excluded. Results Manufactured, sterile prototypes secured MMF successfully in management of unilateral and bilateral mandible and maxilla fractures. All patients reported correction of pre‐operative malocclusion. Application times were typically 12–15 minutes for a single surgeon to achieve MMF. Patients incurred negligible gingival trauma from the technology as the ties require no tissue penetration for application. Conclusions Dental occlusion ties offer a non‐invasive solution featuring operating room efficiency, minimized sharps risk, and less bony and soft tissue trauma than current commercialized solutions. Level of Evidence Therapeutic, IV PMID:28894837

  7. The effect of occlusion therapy on motion perception deficits in amblyopia.

    PubMed

    Giaschi, Deborah; Chapman, Christine; Meier, Kimberly; Narasimhan, Sathyasri; Regan, David

    2015-09-01

    There is growing evidence for deficits in motion perception in amblyopia, but these are rarely assessed clinically. In this prospective study we examined the effect of occlusion therapy on motion-defined form perception and multiple-object tracking. Participants included children (3-10years old) with unilateral anisometropic and/or strabismic amblyopia who were currently undergoing occlusion therapy and age-matched control children with normal vision. At the start of the study, deficits in motion-defined form perception were present in at least one eye in 69% of the children with amblyopia. These deficits were still present at the end of the study in 55% of the amblyopia group. For multiple-object tracking, deficits were present initially in 64% and finally in 55% of the children with amblyopia, even after completion of occlusion therapy. Many of these deficits persisted in spite of an improvement in amblyopic eye visual acuity in response to occlusion therapy. The prevalence of motion perception deficits in amblyopia as well as their resistance to occlusion therapy, support the need for new approaches to amblyopia treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Evolution of endovascular stroke therapies and devices.

    PubMed

    Wallace, Adam N; Kansagra, Akash P; McEachern, James; Moran, Christopher J; Cross, Dewitte T; Derdeyn, Colin P

    2016-01-01

    Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlled trials demonstrating substantial benefit of mechanical thrombectomy in select patients with large vessel cerebrovascular occlusion. This progress is related to several factors, but most importantly, dramatic improvements in speed and rates of recanalization with the latest generation devices. In this article, we review the evolution of endovascular acute ischemic stroke therapies and key design features of the most widely used devices.

  9. Ionic current devices-Recent progress in the merging of electronic, microfluidic, and biomimetic structures.

    PubMed

    Koo, Hyung-Jun; Velev, Orlin D

    2013-05-09

    We review the recent progress in the emerging area of devices and circuits operating on the basis of ionic currents. These devices operate at the intersection of electrochemistry, electronics, and microfluidics, and their potential applications are inspired by essential biological processes such as neural transmission. Ionic current rectification has been demonstrated in diode-like devices containing electrolyte solutions, hydrogel, or hydrated nanofilms. More complex functions have been realized in ionic current based transistors, solar cells, and switching memory devices. Microfluidic channels and networks-an intrinsic component of the ionic devices-could play the role of wires and circuits in conventional electronics.

  10. Study of the occlusion effect induced by an earplug: Numerical modelling and experimental validation

    NASA Astrophysics Data System (ADS)

    Brummund, Martin

    Despite existing limits for occupational noise exposure, professional hearing loss remains a high priority problem both in Quebec and worldwide. Several approaches exist to protect workers from harmful noise levels. The most frequently employed short term solution includes the distribution of hearing protection devices (HPD) such as earplugs and ear muffs. While HPDs offer an inexpensive (e.g. direct cost) and efficient means of protection workers often only tend to wear HPDs for limited amounts of time and, thus, remain at risk of developing professional hearing loss. Discomfort while using HPDs contributes to HPD underutilization and non-use. Two more general categories of discomfort can be distinguished. The category physical discomfort includes, for instance, problems such as heating of the ear and irritation of the ear canal that that occur upon earplug insertion. The category auditory discomfort refers to alterations in the auditory perception of sounds and one's own voice as well as hindered workplace communications. One important auditory discomfort that promotes HPD non-use is the occlusion effect. The occlusion effect occurs upon earplug insertion and describes sound amplification phenomena in the occluded ear canal at the low frequencies. The sound amplification is both perceivable and measurable (e.g., open and occluded sound pressure levels, hearing threshold shift). Additionally, the occlusion effect causes the HPD wearer to perceive his/her own voice as being distorted (e.g. hollow sounding) and physiological noises (e.g. respiration, blood circulation) are amplified also subsequent to earplug insertion. Reducing the occlusion effect has the potential to increase the auditory comfort of HPDs and could help preventing occupational hearing loss in the future. In order to improve this and other shortcomings observed with currently existing HPDs a large research collaboration between the Robert-Sauve research institute in occupational health and safety

  11. [Temporomandibular joint, occlusion and bruxism].

    PubMed

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    PubMed

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  13. Resolving Overlimiting Current Mechanisms in Microchannel-Nanochannel Interface Devices

    NASA Astrophysics Data System (ADS)

    Yossifon, Gilad; Leibowitz, Neta; Liel, Uri; Schiffbauer, Jarrod; Park, Sinwook

    2015-11-01

    We present results demonstrating the space charge-mediated transition between classical, diffusion-limited current and surface-conduction dominant over-limiting currents in a shallow micro-nanochannel device. The extended space charge layer develops at the depleted micro-nanochannel entrance at high current and is correlated with a distinctive maximum in the dc resistance. Experimental results for a shallow surface-conduction dominated system are compared with theoretical models, allowing estimates of the effective surface charge at high voltage to be obtained. Further, we extend the study to microchannels of moderate to large depths where the role of various electro-convection mechanisms becomes dominant. In particular, electro-osmotic of the second kind and electro-osmotic instability (EOI) which competes each other at geometrically heterogeneous (e.g. undulated nanoslot interface, array of nanoslots) nanoslot devices. Also, these effects are also shown to be strongly modulated by the non-ideal permselectivity of the nanochannel.

  14. Spontaneous delayed migration/shortening of the pipeline embolization device: report of 5 cases.

    PubMed

    Chalouhi, N; Tjoumakaris, S I; Gonzalez, L F; Hasan, D; Pema, P J; Gould, G; Rosenwasser, R H; Jabbour, P M

    2013-12-01

    Five patients were found to have spontaneous delayed migration/shortening of their Pipeline Embolization Devices on follow-up angiography. The device migrated proximally in 4 patients and distally in 1 patient. One patient had a subarachnoid hemorrhage and died as a result of migration of the Pipeline Embolization Device, and another patient presented with complete MCA occlusion and was left severely disabled. Mismatch in arterial diameter between inflow and outflow vessels was a constant finding. Migration of the Pipeline Embolization Device was managed conservatively, with additional placement of the device, or with parent vessel occlusion. Obtaining complete expansion of the embolization device by using a longer device, increasing vessel coverage, using adjunctive aneurysm coiling, and avoiding dragging and stretching of the device are important preventive measures. Neurointerventionalists should be aware of this potentially fatal complication and take all necessary preventive measures.

  15. Embolic Protection Devices During TAVI: Current Evidence and Uncertainties.

    PubMed

    Abdul-Jawad Altisent, Omar; Puri, Rishi; Rodés-Cabau, Josep

    2016-10-01

    Transcatheter aortic valve implantation (TAVI) is now the principal therapeutic option in patients with severe aortic stenosis deemed inoperable or at high surgical risk. Implementing TAVI in a lower risk profile population could be limited by relatively high cerebrovascular event rates related to the procedure. Diffusion-weighted magnetic resonance imaging studies have demonstrated the ubiquitous presence of silent embolic cerebral infarcts after TAVI, with some data relating these lesions to subsequent cognitive decline. Embolic protection devices provide a mechanical barrier against debris embolizing to the brain during TAVI. We review the current evidence and ongoing uncertainties faced with the 3 currently available devices (Embrella, TriGuard and Claret) in TAVI. Studies evaluated neurological damage at 3 levels: clinical, subclinical, and cognitive. Feasibility and safety were analyzed for the 3 devices. In terms of efficacy, all studies were exploratory, but none demonstrated significant reductions in clinical event rates. The Embrella and Claret devices demonstrated significant reductions of the total cerebral lesion volume on diffusion-weighted magnetic resonance imaging. Studies evaluating the effects on cognition were also somewhat inconclusive. In conclusion, despite embolic protection devices demonstrating reductions in the total cerebral lesion volume on diffusion-weighted magnetic resonance imaging, the clinical efficacy in terms of preventing stroke/cognitive decline requires confirmation in larger studies. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  16. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  17. Integrated-optic current sensors with a multimode interference waveguide device.

    PubMed

    Kim, Sung-Moon; Chu, Woo-Sung; Kim, Sang-Guk; Oh, Min-Cheol

    2016-04-04

    Optical current sensors based on polarization-rotated reflection interferometry are demonstrated using polymeric integrated optics and various functional optical waveguide devices. Interferometric sensors normally require bias feedback control for maintaining the operating point, which increases the cost. In order to resolve this constraint of feedback control, a multimode interference (MMI) waveguide device is integrated onto the current-sensor optical chip in this work. From the multiple outputs of the MMI, a 90° phase-shifted transfer function is obtained. Using passive quadrature demodulation, we demonstrate that the sensor could maintain the output signal regardless of the drift in the operating bias-point.

  18. Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems.

    PubMed

    Sharif-Kashani, Pooria; Fanney, Douglas; Injev, Val

    2014-07-30

    Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, the WhiteStar Signature® Phacoemulsification System, and the Centurion® Vision System using gravity-fed fluidics. Centurion Active FluidicsTM were also tested at multiple intraoperative pressure target settings. Vacuum rise time was evaluated for Infiniti, WhiteStar Signature, Centurion, and Stellaris® Vision Enhancement systems. Rise time to vacuum limits of 400 and 600 mmHg was assessed at flow rates of 30 and 60 cc/minute. Occlusion break surge was analyzed by 2-way analysis of variance. The Centurion system exhibited substantially less occlusion break surge than the other systems tested. Surge area with Centurion Active Fluidics was similar to gravity fluidics at an equivalent bottle height. At all Centurion Active Fluidics intraoperative pressure target settings tested, surge was smaller than with Infiniti and WhiteStar Signature. Infiniti had the fastest vacuum rise time and Stellaris had the slowest. No system tested reached the 600-mmHg vacuum limit. In this laboratory study, Centurion had the least occlusion break surge and similar vacuum rise times compared with the other systems tested. Reducing occlusion break surge may increase safety of phacoemulsification cataract surgery.

  19. Electronic voltage and current transformers testing device.

    PubMed

    Pan, Feng; Chen, Ruimin; Xiao, Yong; Sun, Weiming

    2012-01-01

    A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz). The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  20. Electronic Voltage and Current Transformers Testing Device

    PubMed Central

    Pan, Feng; Chen, Ruimin; Xiao, Yong; Sun, Weiming

    2012-01-01

    A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz). The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware. PMID:22368510

  1. Electronic monitoring of occlusion treatment for amblyopia in patients aged 7 to 16 years.

    PubMed

    Fronius, Maria; Bachert, Iris; Lüchtenberg, Marc

    2009-10-01

    Age limits for the prescription of amblyopia treatment have been debated and challenged recently, due to results of studies from ophthalmology and the neurosciences. Lack of knowledge about compliance with prescribed treatment is still a major factor for the uncertainty about the amount of plasticity in the visual system of older children and adolescents. The development of devices for the electronic recording of patching (Occlusion Dose Monitor, ODM) has allowed the collection of objective data about daily occlusion. In a prospective study, occlusion dose rates were recorded continuously during 4 months by means of the ODM developed in the Netherlands [1] in nine amblyopic patients between 7 and 16 years of age who were prescribed between 5 and 7 hours of daily patching. Visual acuity was assessed every 3 to 6 weeks. The electronic monitoring showed objective occlusion between 2 and 6.25 hours/day (mean 4.61 h/d) during the first month and 0 to 6.5 hours/day (mean 3.47 h/d) during the following 3 months of treatment. The total acuity gain in the amblyopic eye amounted to between -0.1 and 0.4 log units (mean 0.19) for crowded optotypes. Differences to initial acuities were statistically significant. The calculated average dose-response relationship (cumulated hours occlusion*0.1/acuity gain) for 4 months of occlusion was 234 hours of occlusion per 0.1 log unit of acuity gain. This study presents for the first time objective treatment and dose response data in amblyopic patients beyond the "classical" treatment age. Electronic monitoring of occlusion and considerable amounts of patching were shown to be feasible. The acuity results indicate that there is a potential for improvement, yet treatment seemed to be less efficient than shown by previous studies in younger patients. Continuation of this research may advance the discussion about age-dependent evidence-based amblyopia treatment, about preschool screening for amblyopia and about plasticity of the visual system.

  2. Percutaneous left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation and contraindication for anticoagulation.

    PubMed

    Grosset-Janin, D; Barth, E; Bertrand, B; Detante, O

    2015-05-01

    Stroke, as the third cause of death in developed countries, is a public health issue. Atrial fibrillation is an important cause of ischemic stroke and its prevention is efficient with oral anticoagulation. However, oral anticoagulation can be contraindicated because of hemorrhagic risk related to these treatments. Percutaneous left atrial appendage occlusion is a new alternative of oral anticoagulation for patients with atrial fibrillation and high risk of cardio-embolic stroke but contraindicated for oral anticoagulation. We describe in this paper the procedure of left atrial appendage occlusion with the Amplatzer cardiac plug device, used in our center in Grenoble university hospital, for the first three patients who have been treated with this device. These three patients (one man and two women) have all atrial fibrillation with neurological complication of this arrhythmia, as ischemic stroke. Oral anticoagulation is indicated to prevent another ischemic stroke. However, they all have a high risk of cerebral bleeding for different reasons (cavernomatosis, history of intracerebral hemorrhage and aneurysm of the polygon of Willis). Consequently, they have a high risk of cardio-embolic complication but contraindication for oral anticoagulation. They have been treated by left atrial appendage occlusion with Amplatzer cardiac plug device by percutaneous and trans-septal access. Then, they have been followed by neurologist and cardiologist, with clinical and paraclinical evaluation by echocardiography. Our three first patients have been successfully implanted, without periprocedural complication. No latest adverse event was observed, and particularly no cardiac or neurologic adverse event. The technique of left atrial appendage occlusion is a very interesting and promising technique for ischemic stroke prevention in patient with high risk of cardio-embolic complication because of atrial fibrillation, but high risk of bleeding and contraindication for oral

  3. Comparison of occlusion break responses and vacuum rise times of phacoemulsification systems

    PubMed Central

    2014-01-01

    Background Occlusion break surge during phacoemulsification cataract surgery can lead to potential surgical complications. The purpose of this study was to quantify occlusion break surge and vacuum rise time of current phacoemulsification systems used in cataract surgery. Methods Occlusion break surge at vacuum pressures between 200 and 600 mmHg was assessed with the Infiniti® Vision System, the WhiteStar Signature® Phacoemulsification System, and the Centurion® Vision System using gravity-fed fluidics. Centurion Active FluidicsTM were also tested at multiple intraoperative pressure target settings. Vacuum rise time was evaluated for Infiniti, WhiteStar Signature, Centurion, and Stellaris® Vision Enhancement systems. Rise time to vacuum limits of 400 and 600 mmHg was assessed at flow rates of 30 and 60 cc/minute. Occlusion break surge was analyzed by 2-way analysis of variance. Results The Centurion system exhibited substantially less occlusion break surge than the other systems tested. Surge area with Centurion Active Fluidics was similar to gravity fluidics at an equivalent bottle height. At all Centurion Active Fluidics intraoperative pressure target settings tested, surge was smaller than with Infiniti and WhiteStar Signature. Infiniti had the fastest vacuum rise time and Stellaris had the slowest. No system tested reached the 600-mmHg vacuum limit. Conclusions In this laboratory study, Centurion had the least occlusion break surge and similar vacuum rise times compared with the other systems tested. Reducing occlusion break surge may increase safety of phacoemulsification cataract surgery. PMID:25074069

  4. Evidence overview: benefit of cerebral protection devices during carotid artery stenting.

    PubMed

    Vos, Jan A

    2017-04-01

    Embolic protection devices (EPDs) are often used during carotid angioplasty and stenting (CAS) to reduce procedural cerebral emboli. This manuscript seeks to present an overview of evidence on EPDs during CAS. There are three categories of EPDs: distal occlusion (DO-EPD), filter (F-EPD) and proximal occlusion (PO-EPD). DO and F-EPDs have the disadvantage that the device has to be advanced through the stenosis, without protection and that the device may damage the distal internal carotid artery (ICA). F-EPDs have the advantage of maintaining antegrade flow throughout the procedure. PO-EPDs occlude the ICA and external carotid artery (ECA) (blocking antegrade flow), but do not require manipulation of the stenosis before protection is established. All devices add to procedural time and costs. Many single-center series and meta-analyses have shown lower incidence of procedural complications and surrogate endpoints when EPDs are used. However, these series are hampered by a serious confounder: protected cases were generally performed later, when institutions had more experience and when newer stents, techniques etc. had become available. Two small randomized trials showed no difference between filter-protected and unprotected procedures in clinical outcome, but found significantly more surrogate endpoints (diffusion-weighted MRI lesions and transcranial Doppler detected micro-emboli) in the protected groups. Comparing between groups of EPDs, some studies slightly favored PO to F-EPDs, while others found no difference. All devices were associated with low numbers of clinical cerebral complications, but frequent surrogate signs of cerebral embolization. In conclusion, all currently available EPDs still result in some degree of cerebral embolization. No solid recommendation for a particular type of EPDs, if any, can be derived from literature.

  5. Influence of the fast-processing technique on the number of the occlusal contacts and occlusal vertical dimension of complete dentures.

    PubMed

    Atashrazm, Parsa; Alavijeh, Leila Zamani; Afshar, Maryam Sadat Sadrzadeh

    2011-03-01

    Occlusal errors during acryl processing affect the retention and stability of complete dentures. The aim of the present study was to assess the influence of a short curing technique on the number of occlusal contacts and the occlusal vertical dimension (OVD) of complete dentures. Complete dentures were prepared. The number of occlusal contacts was recorded in centric relation (CR) using 60 µ articulation paper. The OVD was recorded with the waxed trial denture in place. Dentures were then invested and processed with compression molding and short cure water bath technique. The number of occlusal contacts was recorded again. The amount of pin opening was measured for all of the complete dentures on the articulator. Data were analyzed with paired t-test to determine the alterations. The mean number of occlusal contacts before and after processing was 10.9 ± 2.4 and 6.3 ± 3.1 respectively (4.7 ± 1.9 decrease; p < 0.001). A 2 mm mean increase in OVD was observed in 47.7% of the dentures with < 6 occlusal contact changes and 88.9% of the dentures with ≥ 6 occlusal contact changes (p < 0.003). A significant change in the number of occlusal contacts was associated with an OVD increased up to two times. The short curing technique seems to be related to the decreased occlusal contacts and increased OVD. CLINICAL SIGNIFICANCES: More time is needed to adjust the occlusal errors of this method, because it has a negative effect on the morphologic pattern of artificial teeth of complete dentures and thus should be used carefully.

  6. The effectiveness of occlusal splints for sleep bruxism.

    PubMed

    Jagger, Robert

    2008-01-01

    Searches were made using the Cochrane Oral Health Group's Trials Register, Cochrane Central Register of Controlled Trials (CENTRAL), Medline, Embase, LILACS (Latin American & Caribbean Health Sciences Literature), Biblioteca Brasileira de Odontologia, and Dissertations, Theses and Abstracts. Hand searches were made of abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. Randomised controlled trials (RCT) or quasi-RCT were chosen that compared splint therapy concurrently with no treatment, other occlusal appliances, or any other intervention in participants who had sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCT were identified of which five were eventually included. In these, use of an occlusal splint was compared with palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant difference between the occlusal splint and control groups were found in meta-analysis. There is not enough evidence to state that the occlusal splint is effective for treating sleep bruxism. Indication of its use is questionable with regard to sleep outcomes, but there may be some benefit with regard to tooth wear. This systematic review suggests the need for further investigation in more controlled RCT that pay attention to method of allocation, outcome assessment, large sample size, and sufficient duration of followup. The study design must be parallel in order to eliminate

  7. Application of photogrammetry for analysis of occlusal contacts.

    PubMed

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. Occlusal screening as basis for the integration of conjunct gnato-prosthetic devices.

    PubMed

    Popescu, M R; Dăguci, C; Dragomir, L P

    2010-07-01

    The functional disorders of the masticator apparatus impose the accomplishment of a phased assessment protocol which should permit the marking out and prefigure the future treatment plan, at the same time. The association of clinical data with therapeutic options and last but not least with the patient's "expectations" represent a particularly important stage within the final occlusal and aesthetic integration. In order to analyse the data collected through examination various assessment systems are available nowadays which permit the correlation of symptoms identified with adequate diagnoses. The planning of the therapy on the basis of clinical registrations associated with the challenges of the bio-aesthetics shall impose a new conduct within the orofacial rehabilitation of patients.

  9. Occlusal Screening as Basis for the Integration of Conjunct Gnato-Prosthetic Devices

    PubMed Central

    Popescu, M.R.; Dăguci, C.; Dragomir, L.P.

    2010-01-01

    The functional disorders of the masticator apparatus impose the accomplishment of a phased assessment protocol which should permit the marking out and prefigure the future treatment plan, at the same time. The association of clinical data with therapeutic options and last but not least with the patient’s “expectations” represent a particularly important stage within the final occlusal and aesthetic integration. In order to analyse the data collected through examination various assessment systems are available nowadays which permit the correlation of symptoms identified with adequate diagnoses. The planning of the therapy on the basis of clinical registrations associated with the challenges of the bio-aesthetics shall impose a new conduct within the orofacial rehabilitation of patients. PMID:24778829

  10. Occlusal wear and occlusal condition in a convenience sample of young adults.

    PubMed

    Van't Spijker, A; Kreulen, C M; Bronkhorst, E M; Creugers, N H J

    2015-01-01

    To study progression of tooth wear quantitatively in a convenient sample of young adults and to assess possible correlations with occlusal conditions. Twenty-eight dental students participated in a three-year follow up study on tooth wear. Visible wear facets on full arch gypsum casts were assessed using a flatbed scanner and measuring software. Regression analyses were used to assess possible associations between the registered occlusal conditions 'occlusal guidance scheme', 'vertical overbite', 'horizontal overbite', 'depth of sagittal curve', 'canine Angle class relation', 'history of orthodontic treatment', and 'self-reported grinding/clenching' (independent variables) and increase of wear facets (dependent variable). Mean increase in facet surface areas ranged from 1.2 mm2 (premolars, incisors) to 3.4 mm2 (molars); the relative increase ranged from 15% to 23%. Backward regression analysis showed no significant relation for 'group function', 'vertical overbite', 'depth of sagittal curve', 'history of orthodontic treatment' nor 'self-reported clenching. The final multiple linear regression model showed significant associations amongst 'anterior protected articulation' and 'horizontal overbite' and increase of facet surface areas. For all teeth combined, only 'anterior protected articulation' had a significant effect. 'Self reported grinding' did not have a significant effect (p>0.07). In this study 'anterior protected articulation' and 'horizontal overbite', were significantly associated with the progression of tooth wear. Self reported grinding was not significantly associated with progression of tooth wear. Occlusal conditions such as anterior protected articulation and horizontal overbite seem to have an effect on the progression of occlusal tooth wear in this convenient sample of young adults. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Detecting natural occlusion boundaries using local cues

    PubMed Central

    DiMattina, Christopher; Fox, Sean A.; Lewicki, Michael S.

    2012-01-01

    Occlusion boundaries and junctions provide important cues for inferring three-dimensional scene organization from two-dimensional images. Although several investigators in machine vision have developed algorithms for detecting occlusions and other edges in natural images, relatively few psychophysics or neurophysiology studies have investigated what features are used by the visual system to detect natural occlusions. In this study, we addressed this question using a psychophysical experiment where subjects discriminated image patches containing occlusions from patches containing surfaces. Image patches were drawn from a novel occlusion database containing labeled occlusion boundaries and textured surfaces in a variety of natural scenes. Consistent with related previous work, we found that relatively large image patches were needed to attain reliable performance, suggesting that human subjects integrate complex information over a large spatial region to detect natural occlusions. By defining machine observers using a set of previously studied features measured from natural occlusions and surfaces, we demonstrate that simple features defined at the spatial scale of the image patch are insufficient to account for human performance in the task. To define machine observers using a more biologically plausible multiscale feature set, we trained standard linear and neural network classifiers on the rectified outputs of a Gabor filter bank applied to the image patches. We found that simple linear classifiers could not match human performance, while a neural network classifier combining filter information across location and spatial scale compared well. These results demonstrate the importance of combining a variety of cues defined at multiple spatial scales for detecting natural occlusions. PMID:23255731

  12. Hepatic veno-occlusive disease after hematopoietic stem cell transplantation: update on defibrotide and other current investigational therapies.

    PubMed

    Ho, V T; Revta, C; Richardson, P G

    2008-02-01

    Hepatic veno-occlusive disease (VOD), also known as sinusoidal obstruction syndrome (SOS), remains one of the most serious and common complications after myeloablative hematopoietic stem cell transplantation (HSCT). Clinical diagnosis of hepatic VOD is based on the clinical triad of (1) painful hepatomegaly, (2) hyperbilirubinemia and (3) unexplained fluid retention. While milder cases usually resolve spontaneously, severe VOD is associated with a grim prognosis. Defibrotide (DF), a polydisperse mixture of single-stranded oligonucleotide with antithrombotic and fibrinolytic effects on microvascular endothelium, has emerged as an effective and safe therapy for patients with severe VOD. Multiple studies, including a recent large international multicenter phase II clinical trial, have demonstrated 30-60% complete remission rates with DF, even among patients with severe VOD and multiorgan failure. This article will review our current understanding of hepatic VOD, and update the clinical trial experience with DF and other potential therapies for this feared transplant complication.

  13. Development of a reversible vas deferens occlusive device. VI. Long-term evaluation of flexible prosthetic devices.

    PubMed

    Brueschke, E E; Zaneveld, L J; Kaleckas, R A; Wingfield, J R

    1979-05-01

    Fifty-three dogs received implants of several types of flexible devices containing valving mechanisms. These devices were constructed entirely of silicone rubber with the exception of the valve stem, which was made of stainless steel. Generally, the devices were (1) implanted in the open mode and left this way for 27 to 44 months, (2) implanted in the closed mode and kept this way for 11 to 12 months before the valves were reopened, (3) implanted in either the closed or open mode and cycled to the opposite mode every 3 months (four or five cycles), or (4) implanted in either the closed or open mode and cycled to the opposite mode every 6 months (two or three cycles). Different implant methods were also evaluated. Semen analyses were regularly performed on all of the dogs, and a number of the animals were bred during the experiments. It can be concluded that (1) the devices can be opened and closed successfully over long periods, respectively allowing and preventing sperm transport; (2) the breeding ability of the animals is not impaired while the devices are in the open mode, independent of the type of device; (3) the devices do not result in an enhanced incidence of congenital abnormalities in the offspring; and (4) the success rate of device performance does not depend on the method of implanatation used. Thus, the results clearly indicate that the basic mechanism of a soft, reversible valve is a feasible approach to conception control.

  14. Laser targeted photo-occlusion of rat choroidal neovascularization without collateral damage.

    PubMed

    Nishiwaki, Hirokazu; Zeimer, Ran; Goldberg, Morton F; D'Anna, Salvatore A; Vinores, Stanley A; Grebe, Rhonda

    2002-02-01

    Laser targeted photo-occlusion (LTO) is a novel method being developed to treat choroidal neovascular membranes (CNV) in age-related and other macular degenerations. A photosensitive agent, encapsulated in heat-sensitive liposomes, is administered intravenously. A low power laser warms the targeted tissue and releases a bolus of photosensitizer. The photosensitizer is activated after it clears from the normal choriocapillaris but not from the CNV. Forty-five experimental CNV were induced in seven rats. Five weeks after LTO, complete occlusion was observed by laser targeted angiography (LTA) in 76% of treated CNV, and partial occlusion was found in the remaining 24%. The tissues outside the CNV but within the area treated by LTO showed no flow alteration and no dye leakage. All untreated CNV were patent on LTA at 5 weeks. Light microscopy and electron microscopy confirmed the results in treated and control lesions. Moreover, treated areas next to lesions showed normal photoreceptors, retinal pigment epithelium (RPE), Bruch's membrane and choriocapillaris. These results indicate that LTO may improve current photodynamic therapy by alleviating the need for repeated treatments and by avoiding the long-term risks associated with damage to the RPE and occlusion of normal choriocapillaries.

  15. Occlusal splints for treating sleep bruxism (tooth grinding).

    PubMed

    Macedo, C R; Silva, A B; Machado, M A; Saconato, H; Prado, G F

    2007-10-17

    Sleep bruxism is an oral activity characterised by teeth grinding or clenching during sleep. Several treatments for sleep bruxism have been proposed such as pharmacological, psychological, and dental. To evaluate the effectiveness of occlusal splints for the treatment of sleep bruxism with alternative interventions, placebo or no treatment. We searched the Cochrane Oral Health Group's Trials Register (to May 2007); the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, Issue 1); MEDLINE (1966 to May 2007); EMBASE (1980 to May 2007); LILACS (1982 to May 2007); Biblioteca Brasileira de Odontologia (1982 to May 2007); Dissertation, Theses and Abstracts (1981 to May 2007); and handsearched abstracts of particular importance to this review. Additional reports were identified from the reference lists of retrieved reports and from article reviews about treating sleep bruxism. There were no language restrictions. We selected randomised or quasi-randomised controlled trials (RCTs), in which splint therapy was compared concurrently to no treatment, other occlusal appliances, or any other intervention in participants with sleep bruxism. Data extraction was carried out independently and in duplicate. Validity assessment of the included trials was carried out at the same time as data extraction. Discrepancies were discussed and a third review author consulted. The author of the primary study was contacted when necessary. Thirty-two potentially relevant RCTs were identified. Twenty-four trials were excluded. Five RCTs were included. Occlusal splint was compared to: palatal splint, mandibular advancement device, transcutaneous electric nerve stimulation, and no treatment. There was just one common outcome (arousal index) which was combined in a meta-analysis. No statistically significant differences between the occlusal splint and control groups were found in the meta-analyses. There is not sufficient evidence to state that the occlusal splint is

  16. Temporary Vascular Occlusion by Rapid Reverse Phase Polymer: A Preliminary In Vitro Study of Retrograde Injection

    PubMed Central

    Dregelid, Einar

    2012-01-01

    During vascular surgical operations, there is a need for a simpler and more reliable method of temporary arterial occlusion than those currently employed, especially of heavily calcified arteries. A thermosensitive polymer, LeGoo (LG) (Pluromed, Woburn, MA), has been used successfully for temporary vascular occlusion. It has hitherto been injected by a cannula that has been introduced into the artery to be occluded, here henceforth called the “cannulation method.” Injection into arterial ostia without cannulation, using an injection device that arrests blood flow during the injection, here henceforth called “a retrograde method” may enable temporary hemostasis when ostial stenoses render it impossible to inject LG using the cannulation method. The objective of the present study was to study the feasibility of a retrograde method and to compare it with the cannulation method in an in vitro model, incorporating a narrow orifice to simulate ostial stenosis, using tap water at 37°C instead of blood. The retrograde method of LG injection, using a modified paediatric Foley catheter, turned out to be feasible to produce a durable LG plug more reliably, at higher water pressure and with less deep LG injection than with the cannulation method. PMID:22888352

  17. Occlusal adjustment using the bite plate-induced occlusal position as a reference position for temporomandibular disorders: a pilot study

    PubMed Central

    2010-01-01

    Background Many researchers have not accepted the use of occlusal treatments for temporomandibular disorders (TMDs). However, a recent report described a discrepancy between the habitual occlusal position (HOP) and the bite plate-induced occlusal position (BPOP) and discussed the relation of this discrepancy to TMD. Therefore, the treatment outcome of evidence-based occlusal adjustments using the bite plate-induced occlusal position (BPOP) as a muscular reference position should be evaluated in patients with TMD. Methods The BPOP was defined as the position at which a patient voluntarily closed his or her mouth while sitting in an upright posture after wearing an anterior flat bite plate for 5 minutes and then removing the plate. Twenty-one patients with TMDs underwent occlusal adjustment using the BPOP. The occlusal adjustments were continued until bilateral occlusal contacts were obtained in the BPOP. The treatment outcomes were evaluated using the subjective dysfunction index (SDI) and the Helkimo Clinical Dysfunction Index (CDI) before and after the occlusal adjustments; the changes in these two indices between the first examination and a one-year follow-up examination were then analyzed. In addition, the difference between the HOP and the BPOP was three-dimensionally measured before and after the treatment. Results The percentage of symptom-free patients after treatment was 86% according to the SDI and 76% according to the CDI. The changes in the two indices after treatment were significant (p < 0.001). The changes in the mean HOP-BPOP differences on the x-axis (mediolateral) and the y-axis (anteroposterior) were significant (p < 0.05), whereas the change on the z-axis (superoinferior) was not significant (p > 0.1). Conclusion Although the results of the present study should be confirmed in other studies, a randomized clinical trial examining occlusal adjustments using the BPOP as a reference position appears to be warranted. PMID:20346167

  18. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    PubMed

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  19. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prabhudesai, V., E-mail: v_prabhudesai@hotmail.com; Mitra, K.; West, D. J.

    2003-09-15

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome.

  20. Acute left main coronary artery occlusion

    PubMed Central

    Burgazli, K. Mehmet; Bilgin, Mehmet; Soydan, Nedim; Chasan, Ridvan; Erdogan, Ali

    2013-01-01

    The treatment of an acute left main coronary artery occlusion still poses a challenge. In this case report we present a 50-year-old patient with an acute occlusion of the left main artery. After a successful angioplasty without “stenting” due to the complexity of the stenosis the patient underwent a successful bypass surgery. We discuss the therapeutic options of acute left main occlusion regarding medical, interventional and surgical options. PMID:24353543

  1. A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement.

    PubMed

    Goethals, Pauwel; Chaobal, Harshu; Reynaerts, Dominiek; Schaner, David

    2014-04-01

    We present a new device for verifying endotracheal tube (ETT) position that uses specialized sensors intended to distinguish anatomical features of the trachea and esophagus. This device has the potential to increase the safety of resuscitation, surgery, and mechanical ventilation and decrease the morbidity, mortality, and health care costs associated with esophageal intubation and unintended extubation by potentially improving the process and maintenance of endotracheal intubation. The device consists of a tactile sensor connected to the airway occlusion cuff of an ETT. It is intended to detect the presence or absence of tracheal rings immediately upon inflation of the airway occlusion cuff. The initial study detailed here verifies that a prototype device can detect contours similar to tracheal rings in a tracheal model.

  2. Inheritance of Occlusal Topography: A Twin Study

    PubMed Central

    Su, C-Y.; Corby, P.M.; Elliot, M.A.; Studen-Pavlovich, D.A.; Ranalli, D.N.; Rosa, B.; Wessel, J.; Schork, N.J.; Hart, T.C.; Bretz, W.A.

    2011-01-01

    Aim This was to determine the relative contribution of genetic factors on the morphology of occlusal surfaces of mandibular primary first molars by employing the twin study model. Methods The occlusal morphology of mandibular primary first molar teeth from dental casts of 9 monozygotic (MZ) twin pairs and 12 dizygotic (DZ) twin pairs 4 to 7 years old, were digitized by contact-type three-dimensional (3D) scanner. To compare the similarity of occlusal morphology between twin sets, each twin pair of occlusal surfaces was superimposed to establish the best fit by using computerized least squared techniques. Heritability was computed using a variance component model, adjusted for age and gender. Results DZ pairs demonstrated a greater degree of occlusal morphology variance. The total amount of difference in surface overlap was 0.0508 mm (0.0018 (inches) for the MZ (n=18) sample and 0.095 mm (0.0034 inches) for the DZ (n=24) sample and were not statistically significant (p=0.2203). The transformed mean differences were not statistically significantly different (p=0.2203). Heritability estimates of occlusal surface areas for right and left mandibular primary first molars were 97.5% and 98.2% (p<0.0001), respectively. Conclusions Occlusal morphology of DZ twin pairs was more variable than that of MZ twin pairs. Heritability estimates revealed that genetic factors strongly influence occlusal morphology of mandibular primary first molars. PMID:18328234

  3. Design and Verification of a Shape Memory Polymer Peripheral Occlusion Device

    PubMed Central

    Landsman, Todd L.; Bush, Ruth L.; Glowczwski, Alan; Horn, John; Jessen, Staci L.; Ungchusri, Ethan; Diguette, Katelin; Smith, Harrison R.; Hasan, Sayyeda M.; Nash, Daniel; Clubb, Fred J.; Maitland, Duncan J.

    2017-01-01

    Shape memory polymer foams have been previously investigated for their safety and efficacy in treating a porcine aneurysm model. Their biocompatibility, rapid thrombus formation, and ability for endovascular catheter-based delivery to a variety of vascular beds makes these foams ideal candidates for use in numerous embolic applications, particularly within the peripheral vasculature. This study sought to investigate the material properties, safety, and efficacy of a shape memory polymer peripheral embolization device in vitro. The material characteristics of the device were analyzed to show tunability of the glass transition temperature (Tg) and the expansion rate of the polymer to ensure adequate time to deliver the device through a catheter prior to excessive foam expansion. Mechanical analysis and flow migration studies were performed to ensure minimal risk of vessel perforation and undesired thromboembolism upon device deployment. The efficacy of the device was verified by performing blood flow studies that established affinity for thrombus formation and blood penetration throughout the foam and by delivery of the device in an ultrasound phantom that demonstrated flow stagnation and diversion of flow to collateral pathways. PMID:27419615

  4. Occlusal splint versus modified nociceptive trigeminal inhibition splint in bruxism therapy: a randomized, controlled trial using surface electromyography.

    PubMed

    Dalewski, B; Chruściel-Nogalska, M; Frączak, B

    2015-12-01

    An occlusal splint and a modified nociceptive trigeminal inhibition splint (AMPS, anterior deprogrammer, Kois deprogrammer, Lucia jig, etc.) are commonly and quite frequently used in the treatment of masticatory muscle disorders, although their sustainable and long-lasting effect on these muscles' function is still not very well known. Results of scant surface electromyography studies in patients with temporomandibular disorders have been contradictory. The aim of this study was to evaluate both devices in bruxism therapy; EMG activity levels during postural activity and maximum voluntary contraction of the superficial temporal and masseter muscles were compared before and after 30 days of treatment. Surface electromyography of the examined muscles was performed in two groups of bruxers (15 patients each). Patients in the first group used occlusal splints, while those in the second used modified nociceptive trigeminal inhibition splints. The trial was randomized, controlled and semi-blind. Neither device affected the asymmetry index or postural activity/maximum voluntary contraction ratio after 1 month of treatment. Neither the occlusal nor the nociceptive trigeminal inhibition splint showed any significant influence on the examined muscles. Different scientific methods should be considered in clinical applications that require either direct influence on the muscles' bioelectrical activity or a quantitative measurement of the treatment quality. © 2015 Australian Dental Association.

  5. Current State and Future Perspectives of Energy Sources for Totally Implantable Cardiac Devices.

    PubMed

    Bleszynski, Peter A; Luc, Jessica G Y; Schade, Peter; PhilLips, Steven J; Tchantchaleishvili, Vakhtang

    There is a large population of patients with end-stage congestive heart failure who cannot be treated by means of conventional cardiac surgery, cardiac transplantation, or chronic catecholamine infusions. Implantable cardiac devices, many designated as destination therapy, have revolutionized patient care and outcomes, although infection and complications related to external power sources or routine battery exchange remain a substantial risk. Complications from repeat battery replacement, power failure, and infections ultimately endanger the original objectives of implantable biomedical device therapy - eliminating the intended patient autonomy, affecting patient quality of life and survival. We sought to review the limitations of current cardiac biomedical device energy sources and discuss the current state and trends of future potential energy sources in pursuit of a lifelong fully implantable biomedical device.

  6. Sinusoidal obstruction syndrome/veno-occlusive disease: current situation and perspectives—a position statement from the European Society for Blood and Marrow Transplantation (EBMT)

    PubMed Central

    Mohty, M; Malard, F; Abecassis, M; Aerts, E; Alaskar, A S; Aljurf, M; Arat, M; Bader, P; Baron, F; Bazarbachi, A; Blaise, D; Ciceri, F; Corbacioglu, S; Dalle, J-H; Duarte, R F; Fukuda, T; Huynh, A; Masszi, T; Michallet, M; Nagler, A; NiChonghaile, M; Pagluica, T; Peters, C; Petersen, F B; Richardson, P G; Ruutu, T; Savani, B N; Wallhult, E; Yakoub-Agha, I; Carreras, E

    2015-01-01

    Sinusoidal obstruction syndrome or veno-occlusive disease (SOS/VOD) is a potentially life-threatening complication of hematopoietic SCT (HSCT). This review aims to highlight, on behalf of the European Society for Blood and Marrow Transplantation, the current knowledge on SOS/VOD pathophysiology, risk factors, diagnosis and treatments. Our perspectives on SOS/VOD are (i) to accurately identify its risk factors; (ii) to define new criteria for its diagnosis; (iii) to search for SOS/VOD biomarkers and (iv) to propose prospective studies evaluating SOS/VOD prevention and treatment in adults and children. PMID:25798682

  7. 77 FR 68788 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-16

    ... diverting cardiac output to the cerebral vasculature via partial occlusion of the descending aorta... inflation of the individual balloons. The device is placed in the descending aorta. On March 30, 2005, a... the descending aorta (K090970). CoAxia has submitted a de novo application for the NeuroFlo for the...

  8. Neuromuscular dentistry: Occlusal diseases and posture.

    PubMed

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture.

  9. The effect of resting blood flow occlusion on exercise tolerance and W'.

    PubMed

    Broxterman, Ryan M; Craig, Jesse C; Ade, Carl J; Wilcox, Samuel L; Barstow, Thomas J

    2015-09-15

    It has previously been postulated that the anaerobic work capacity (W') may be utilized during resting blood flow occlusion in the absence of mechanical work. We tested the hypothesis that W' would not be utilized during an initial range of time following the onset of resting blood flow occlusion, after which W' would be utilized progressively more. Seven men completed blood flow occlusion constant power severe intensity handgrip exercise to task failure following 0, 300, 600, 900, and 1,200 s of resting blood flow occlusion. The work performed above critical power (CP) was not significantly different between the 0-, 300-, and 600-s conditions and was not significantly different from the total W' available. Significantly less work was performed above CP during the 1,200-s condition than the 900-s condition (P < 0.05), while both conditions were significantly less than the 0-, 300-, and 600-s conditions (P < 0.05). The work performed above CP during these conditions was significantly less than the total W' available (P < 0.05). The utilization of W' during resting blood flow occlusion did not begin until 751 ± 118 s, after which time W' was progressively utilized. The current findings demonstrate that W' is not utilized during the initial ∼751 s of resting blood flow occlusion, but is progressively utilized thereafter, despite no mechanical work being performed. Thus, the utilization of W' is not exclusive to exercise, and a constant amount of work that can be performed above CP is not the determining mechanism of W'. Copyright © 2015 the American Physiological Society.

  10. Design and verification of a shape memory polymer peripheral occlusion device.

    PubMed

    Landsman, Todd L; Bush, Ruth L; Glowczwski, Alan; Horn, John; Jessen, Staci L; Ungchusri, Ethan; Diguette, Katelin; Smith, Harrison R; Hasan, Sayyeda M; Nash, Daniel; Clubb, Fred J; Maitland, Duncan J

    2016-10-01

    Shape memory polymer foams have been previously investigated for their safety and efficacy in treating a porcine aneurysm model. Their biocompatibility, rapid thrombus formation, and ability for endovascular catheter-based delivery to a variety of vascular beds makes these foams ideal candidates for use in numerous embolic applications, particularly within the peripheral vasculature. This study sought to investigate the material properties, safety, and efficacy of a shape memory polymer peripheral embolization device in vitro. The material characteristics of the device were analyzed to show tunability of the glass transition temperature (Tg) and the expansion rate of the polymer to ensure adequate time to deliver the device through a catheter prior to excessive foam expansion. Mechanical analysis and flow migration studies were performed to ensure minimal risk of vessel perforation and undesired thromboembolism upon device deployment. The efficacy of the device was verified by performing blood flow studies that established affinity for thrombus formation and blood penetration throughout the foam and by delivery of the device in an ultrasound phantom that demonstrated flow stagnation and diversion of flow to collateral pathways. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Bilateral Internal Carotid Artery Occlusion, External Carotid Artery Stenosis, and Vertebral Artery Kinking: May It Be Asymptomatic?

    PubMed

    Fatic, Nikola; Jaffer, Usman; Ivana, Saicic; Gordana, Globarevic-Vukcevic; Markovic, Dragan; Kostic, Dusan; Davidovic, Lazar

    2017-10-01

    The clinical spectrum of internal carotid artery occlusion ranges from being a completely asymptomatic occlusion to a devastating stroke or death. The prevalence of asymptomatic internal carotid artery occlusion is unknown, particularly for bilateral occlusion. The distal branches of the external carotid artery anastomose with distal branches of the internal carotid artery provide important sources of collateral circulation to the brain. Stenosis of the external carotid artery with ipsilateral/bilateral internal occlusion may result in ischemic sequelae. Coiling or kinking of the vertebral artery is a rare morphological entity that is infrequently reported because it remains asymptomatic and has no clinical relevance. Currently, there is little evidence to support management strategies for this disease entity and no official recommendations for asymptomatic bilateral carotid artery occlusion. We present a case of a 62-year-old female with asymptomatic bilateral internal carotid artery occlusion, bilateral external carotid artery stenoses, and bilateral kinking of the vertebral artery at the V2 segment, who has been successfully managed conservatively for over 5 years. An individualized approach to management of patients with bilateral internal carotid artery occlusion, especially in combination with external carotid artery stenosis and elongation malformations of the vertebral artery is key to a successful strategy. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Special report: Occlusive cuff controller

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1975-01-01

    A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

  13. Hysteroscopic proximal tubal occlusion versus laparoscopic salpingectomy as a treatment for hydrosalpinges prior to IVF or ICSI: an RCT.

    PubMed

    Dreyer, K; Lier, M C I; Emanuel, M H; Twisk, J W R; Mol, B W J; Schats, R; Hompes, P G A; Mijatovic, V

    2016-09-01

    Does hysteroscopic proximal tubal occlusion by intratubal devices as a treatment for hydrosalpinges result in comparable ongoing pregnancy rates following IVF/ICSI when compared with laparoscopic salpingectomy? Hysteroscopic proximal tubal occlusion by intratubal devices is inferior to laparoscopic salpingectomy in the treatment of hydrosalpinges in women undergoing IVF/ICSI with respect to ongoing pregnancy rates. It is known that women with hydrosalpinges undergoing IVF have poorer pregnancy outcomes compared with women with other forms of tubal infertility. In these women, both laparoscopic salpingectomy and laparoscopic proximal tubal ligation are known to improve IVF outcomes. At present, it is unclear whether a less-invasive hysteroscopic treatment with intratubal devices leads to similar ongoing pregnancy rates following IVF when compared with laparoscopic salpingectomy. A two-centre, randomized, controlled, non-inferiority trial. Between October 2009 and December 2014 a total of 85 women were included in this study; of whom, 42 were randomized to hysteroscopic proximal occlusion by intratubal device placement and 43 were randomized to laparoscopic salpingectomy. Randomization was based on a computer-generated randomization list. The study was unblinded. The primary outcome was ongoing pregnancy rate, defined as a fetal heartbeat on ultrasound beyond 10-week gestation following one IVF/ICSI treatment (fresh and frozen-thawed embryo transfers). We studied women aged 18-41 years, with uni- or bilateral ultrasound visible hydrosalpinges who were scheduled for an IVF/ICSI treatment. The ongoing pregnancy rates per patient according to the intention-to-treat principle were 11/42 (26.2%) after hysteroscopic proximal occlusion by intratubal devices (intervention group) versus 24/43 (55.8%) after laparoscopic salpingectomy (control group) (P = 0.008) [absolute difference: 26.1%; 95% confidence interval (CI): 0.5-51.7, relative risk (RR): 0.56; 95% CI: 0.31-1.03, P

  14. Biomechanics of occlusion--implications for oral rehabilitation.

    PubMed

    Peck, C C

    2016-03-01

    The dental occlusion is an important aspect of clinical dentistry; there are diverse functional demands ranging from highly precise tooth contacts to large crushing forces. Further, there are dogmatic, passionate and often diverging views on the relationship between the dental occlusion and various diseases and disorders including temporomandibular disorders, non-carious cervical lesions and tooth movement. This study provides an overview of the biomechanics of the masticatory system in the context of the dental occlusion's role in function. It explores the adaptation and precision of dental occlusion, its role in bite force, jaw movement, masticatory performance and its influence on the oro-facial musculoskeletal system. Biomechanics helps us better understand the structure and function of biological systems and consequently an understanding of the forces on, and displacements of, the dental occlusion. Biomechanics provides insight into the relationships between the dentition, jaws, temporomandibular joints, and muscles. Direct measurements of tooth contacts and forces are difficult, and biomechanical models have been developed to better understand the relationship between the occlusion and function. Importantly, biomechanical research will provide knowledge to help correct clinical misperceptions and inform better patient care. The masticatory system demonstrates a remarkable ability to adapt to a changing biomechanical environment and changes to the dental occlusion or other components of the musculoskeletal system tend to be well tolerated. © 2015 John Wiley & Sons Ltd.

  15. Dental occlusion and temporomandibular disorders.

    PubMed

    Stone, J Caitlin; Hannah, Andrew; Nagar, Nathan

    2017-10-27

    Data sourcesMedline, Scopus and Google Scholar.Study selectionTwo reviewers selected studies independently. English language clinical studies assessing the association between temporomandibular disorders (TMD) and features of dental occlusion were considered.Data extraction and synthesisStudy quality was assessed based on the Newcastle-Ottawa Scale (NOS) and a narrative synthesis was presented.ResultsIn all 25 studies (17 case-control, eight comparative) were included. Overall there was a high variability between occlusal features and TMD diagnosis. Findings were consistent with a lack of clinically relevant association between TMD and dental occlusion. Only two studies were associated with TMD in the majority (≥50%) of single variable analyses in patient populations. Only mediotrusive interferences are associated with TMD in the majority of multiple variable analyses.ConclusionsThe findings support the absence of a disease-specific association, there is no ground to hypothesise a major role for dental occlusion in the pathophysiology of TMDs. Dental clinicians are thus encouraged to move forward and abandon the old-fashioned gnathological paradig.

  16. Conventional occlusion versus pharmacologic penalization for amblyopia.

    PubMed

    Li, Tianjing; Shotton, Kate

    2009-10-07

    Amblyopia is defined as defective visual acuity in one or both eyes without demonstrable abnormality of the visual pathway, and is not immediately resolved by wearing glasses. To assess the effectiveness and safety of conventional occlusion versus atropine penalization for amblyopia. We searched CENTRAL, MEDLINE, EMBASE, LILACS, the WHO International Clinical Trials Registry Platform, preference lists, science citation index and ongoing trials up to June 2009. We included randomized/quasi-randomized controlled trials comparing conventional occlusion to atropine penalization for amblyopia. Two authors independently screened abstracts and full text articles, abstracted data, and assessed the risk of bias. Three trials with a total of 525 amblyopic eyes were included. One trial was assessed as having a low risk of bias among these three trials, and one was assessed as having a high risk of bias.Evidence from three trials suggests atropine penalization is as effective as conventional occlusion. One trial found similar improvement in vision at six and 24 months. At six months, visual acuity in the amblyopic eye improved from baseline 3.16 lines in the occlusion and 2.84 lines in the atropine group (mean difference 0.034 logMAR; 95% confidence interval (CI) 0.005 to 0.064 logMAR). At 24 months, additional improvement was seen in both groups; but there continued to be no meaningful difference (mean difference 0.01 logMAR; 95% CI -0.02 to 0.04 logMAR). The second trial reported atropine to be more effective than occlusion. At six months, visual acuity improved 1.8 lines in the patching group and 3.4 lines in the atropine penalization group, and was in favor of atropine (mean difference -0.16 logMAR; 95% CI -0.23 to -0.09 logMAR). Different occlusion modalities were used in these two trials. The third trial had inherent methodological flaws and limited inference could be drawn.No difference in ocular alignment, stereo acuity and sound eye visual acuity between occlusion and

  17. Use of a Re-entry Device in Left Subclavian Occlusion: Case Series.

    PubMed

    Thomas, Wiliam Rhodri; Chick, Christopher; Goyal, Nimit

    2018-01-01

    To describe the use of a re-entry catheter in the endovascular treatment of left subclavian stenosis. We present three patients where initial attempts at re-vascularisation using standard techniques were unsuccessful. An OUTBACK catheter was employed to facilitate re-entry in these patients. True lumen re-entry was achieved in all patients, leading to successful treatment of all stenoses. There was a lack of filling of the left vertebral artery post-angioplasty in one patient; this was not clinically significant. The case series presented is encouraging for the use of a re-entry catheter in the treatment of subclavian occlusion. In our limited experience this has proved to be a safe technique for use in patients who fail re-vascularisation by standard methods; a larger study is required to confirm this.

  18. Necrotizing Fasciitis of the Periorbital Region Complicated by Combined Central Retinal Artery Occlusion, Central Retinal Vein Occlusion, and Posterior Ciliary Occlusion.

    PubMed

    Sultan, Harris; Malik, Amina; Li, Helen K; Chévez-Barrios, Patricia; Lee, Andrew G

    A 50 year-old man on immunosuppressive agents presented with left eye vision loss, periorbital swelling, pain, and ophthalmoplegia. The patient was clinically found to have a central retinal artery and vein occlusion. A CT scan was performed which demonstrated intraorbital fat stranding, however the patient lacked sinus disease. The etiology of the orbital infection was held in question. The area was debrided in the operating room, and the specimen demonstrated group A streptococcal species consistent with necrotizing fasciitis. Periorbital necrotizing fasciitis should be suspected in patients with rapidly progressive orbital symptoms without sinus disease as lack of surgical intervention can result in poor outcomes. The unusual aspect to this case is the mechanism of vision loss, as the authors hypothesize that there was vascular infiltration of the infection resulting in the central retinal artery occlusion and central retinal vein occlusion which have not been previously reported secondary to necrotizing fasciitis of the orbit.

  19. Neuromuscular dentistry: Occlusal diseases and posture

    PubMed Central

    Khan, Mohd Toseef; Verma, Sanjeev Kumar; Maheshwari, Sandhya; Zahid, Syed Naved; Chaudhary, Prabhat K.

    2013-01-01

    Neuromuscular dentistry has been a controversial topic in the field of dentistry and still remains debatable. The issue of good occlusion and sound health has been repeatedly discussed. Sometimes we get complains of sensitive teeth and sometimes of tired facial muscles on getting up in the morning. Owing to the intimate relation of masticatory apparatus with the cranium and cervico-scapular muscular system, the disorders in any system, draw attention from concerned clinicians involved in management, to develop an integrated treatment protocol for the suffering patients. There may be patients reporting to the dental clinics after an occlusal restoration or extraction, having pain in or around the temporomandibular joint, headache or neck pain. Although their esthetic demands must not be undermined during the course of treatment plan, whenever dental treatment of any sort is planned, occlusion/bite should be given prime importance. Very few dentist are able to diagnose the occlusal disease and of those who diagnose many people resort to aggressive treatment modalities. This paper aims to report the signs of occlusal disease, and discuss their association with TMDs and posture. PMID:25737904

  20. Relationship between occlusal force and falls among community-dwelling elderly in Japan: a cross-sectional correlative study.

    PubMed

    Eto, Maki; Miyauchi, Shinji

    2018-05-09

    precise prediction of fall risks among the community-dwelling elderly. The latest occlusal force measurement device is non-invasive and easy to use. Public health nurses can introduce it at periodical community health checkup assembly events, which might contribute to raising awareness among community-dwelling elderly individuals and public health nurses about fall prevention and prediction.

  1. Optical see-through head-mounted display with occlusion capability

    NASA Astrophysics Data System (ADS)

    Gao, Chunyu; Lin, Yuxiang; Hua, Hong

    2013-05-01

    Lack of mutual occlusion capability between computer-rendered and real objects is one of fundamental problems for most existing optical see-through head-mounted displays (OST-HMD). Without the proper occlusion management, the virtual view through an OST-HMD appears "ghost-like", floating in the real world. To address this challenge, we have developed an innovative optical scheme that uniquely combines the eyepiece and see-through relay optics to achieve an occlusion-capable OST-HMD system with a very compelling form factor and high optical performances. The proposed display system was based on emerging freeform optical design technologies and was designed for highly efficient liquid crystal on silicon (LCoS) type spatial light modulator (SLM) and bright Organic LED (OLED) microdisplay. The proposed display technology was capable of working in both indoor and outdoor environments. Our current design offered a 1280x1024 color resolution based on 0.8" microdisplay and SLM. The MTF values for the majority of the fields at the cutoff frequency of 40lps/mm, which is determined by the pixel size of the microdisplay, are better than 15%. The design achieved a diagonal FOV of 40 degrees, 31.7 degrees horizontally and 25.6 degrees vertically, an exit pupil diameter of 8mm (non-vignetted), and an eye clearance of 18mm. The optics weights about 20 grams per eye. Our proposed occlusion capable OST-HMD system can easily find myriads of applications in various military and commercial sectors such as military training, gaming and entertainment.

  2. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Petrocelli, Francesco

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  3. The role of "rescue saccades" in tracking objects through occlusions.

    PubMed

    Zelinsky, Gregory J; Todor, Andrei

    2010-12-29

    We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking.

  4. Subadventitial techniques for chronic total occlusion percutaneous coronary intervention: The concept of "vessel architecture".

    PubMed

    Azzalini, Lorenzo; Carlino, Mauro; Brilakis, Emmanouil S; Vo, Minh; Rinfret, Stéphane; Uretsky, Barry F; Karmpaliotis, Dimitri; Colombo, Antonio

    2018-03-01

    Despite improvements in guidewire technologies, the traditional antegrade wire escalation approach to chronic total occlusion (CTO) recanalization is successful in only 60-80% of selected cases. In particular, long, calcified, and tortuous occlusions are less successfully approached with a true-to-true lumen approach. Frequently, the guidewire tracks into the subadventitial space, with no guarantee of distal re-entry into the true lumen. The ability to manage the subadventitial space has been a key step in the tremendous improvement in success rates of contemporary CTO percutaneous coronary intervention (PCI), whether operating antegradely or retrogradely. A modern approach to CTO PCI involves understanding the concept of "vessel architecture," which is based on the distinction between coronary structures (occlusive plaque, comprising the disrupted intima and media, and the outer adventitia) and extravascular space. The vessel architecture represents a safe work environment for guidewire and device manipulation. This review provides an anatomy-based description of the concept of vessel architecture, along with a historical perspective of subadventitial techniques for CTO PCI, and outcome data of CTO PCI utilizing the subadventitial space. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. A microwave field-driven transistor-like skyrmionic device with the microwave current-assisted skyrmion creation

    NASA Astrophysics Data System (ADS)

    Xia, Jing; Huang, Yangqi; Zhang, Xichao; Kang, Wang; Zheng, Chentian; Liu, Xiaoxi; Zhao, Weisheng; Zhou, Yan

    2017-10-01

    Magnetic skyrmion is a topologically protected domain-wall structure at nanoscale, which could serve as a basic building block for advanced spintronic devices. Here, we propose a microwave field-driven skyrmionic device with the transistor-like function, where the motion of a skyrmion in a voltage-gated ferromagnetic nanotrack is studied by micromagnetic simulations. It is demonstrated that the microwave field can drive the motion of a skyrmion by exciting the propagating spin waves, and the skyrmion motion can be governed by a gate voltage. We also investigate the microwave current-assisted creation of a skyrmion to facilitate the operation of the transistor-like skyrmionic device on the source terminal. It is found that the microwave current with an appropriate frequency can reduce the threshold current density required for the creation of a skyrmion from the ferromagnetic background. The proposed transistor-like skyrmionic device operated with the microwave field and current could be useful for building future skyrmion-based circuits.

  6. The current situation and development of medical device testing institutes in China.

    PubMed

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  7. Occlusion issues in early Renaissance art

    PubMed Central

    Gillam, Barbara

    2011-01-01

    Early Renaissance painters innovatively attempted to depict realistic three-dimensional scenes. A major problem was to produce the impression of overlap for surfaces that occlude one another in the scene but are adjoined in the picture plane. Much has been written about perspective in art but little about occlusion. Here I examine some of the strategies for depicting occlusion used by early Renaissance painters in relation to ecological considerations and perceptual research. Perceived surface overlap is often achieved by implementing the principle that an occluding surface occludes anything behind it, so that occlusion perception is enhanced by a lack of relationship of occluding contour to occluded contours. Some well-known figure-ground principles are also commonly used to stratify adjoined figures. Global factors that assist this stratification include the placement of figures on a ground plane, a high viewpoint, and figure grouping. Artists of this period seem to have differed on whether to occlude faces and heads, often carefully avoiding doing so. Halos were either eliminated selectively or placed oddly to avoid such occlusions. Finally, I argue that the marked intransitivity in occlusion by architecture in the paintings of Duccio can be related to the issue of perceptual versus cognitive influences on the visual impact of paintings. PMID:23145262

  8. Predictive Factors for Patients Undergoing ASD Device Occlusion Who "Crossover" to Surgery.

    PubMed

    Mulukutla, Venkatachalam; Qureshi, Athar M; Pignatelli, Ricardo; Ing, Frank F

    2018-03-01

    The aim of this study was to define characteristics of those patients who are referred for device closure of an Atrial septal defect (ASD), but identified to "crossover" surgery. All patients who underwent surgical and device (Amplatzer or Helex occluder) closures of secundum ASDs from 2001 to 2010 were reviewed and organized into three groups: surgical closure, device closure, and "crossover" group. 369 patients underwent ASD closure (265 device, 104 surgical). 42 of the 265 patients referred for device closure "crossed over" to the surgical group at various stages of the catheterization procedure. The device group had defect size measuring 14.2 mm (mean) and an ASD index (Defect Size (mm)/BSA) of 14.0 compared to the corresponding values in the surgical group (20.1 mm, ASD index 25.9) (P < 0.001) and in the "crossover" group (20.7 mm, 22.6 ASD index) (P < 0.001). 79 patients in the device group had a deficient rim, and 86% were located in the retroaortic region. 33 patients in the "crossover" group had deficient rims with 70% deficiency in the posterior/inferior rim. The device group with deficient rims had an ASD index of 14.7 compared with the crossover group ASD index of 23.8 (P < 0.001). Comparing the device and "crossover" groups, an ASD index greater than 23.7 had a 90% specificity in "crossing over" to surgery. The crossover and surgical groups had statistically larger ASD defect size indexes compared with the device group. Deficient rim in the posterior/inferior rim is associated with a large ASD size index which is a predictive factor for crossing over to surgery. Catheterization did not negatively impact surgical results in the "crossover" group.

  9. Improvised explosive devices: pathophysiology, injury profiles and current medical management.

    PubMed

    Ramasamy, A; Hill, A M; Clasper, J C

    2009-12-01

    The improvised explosive device (IED), in all its forms, has become the most significant threat to troops operating in Afghanistan and Iraq. These devices range from rudimentary home made explosives to sophisticated weapon systems containing high-grade explosives. Within this broad definition they may be classified as roadside explosives and blast mines, explosive formed pojectile (EFP) devices and suicide bombings. Each of these groups causeinjury through a number of different mechanisms and can result in vastly different injury profiles. The "Global War on Terror" has meant that incidents which were previously exclusively seen in conflict areas, can occur anywhere, and clinicians who are involved in emergency trauma care may be required to manage casualties from similar terrorist attacks. An understanding of the types of devices and their pathophysiological effects is necessary to allow proper planning of mass casualty events and to allow appropriate management of the complex poly-trauma casualties they invariably cause. The aim of this review article is to firstly describe the physics and injury profile from these different devices and secondly to present the current clinical evidence that underpins their medical management.

  10. Predictors of early stent occlusion among plastic biliary stents.

    PubMed

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  11. Influence of denture adhesives on occlusion and disocclusion times.

    PubMed

    Abdelnabi, Mohamed Hussein; Swelem, Amal Ali; Al-Dharrab, Ayman A

    2016-03-01

    The effectiveness of adhesives in enhancing several functional aspects of complete denture performance has been well established. The direct influence of adhesives on occlusal contact simultaneity has not yet been investigated. The purpose of this crossover clinical trial was to evaluate quantitatively the influence of adhesives on occlusal balance by recording timed occlusal contacts; namely occlusion time (OT) and disocclusion time during right (DT-right) and left (DT-left) excursions by using computerized occlusal analysis. A crossover clinical trial was adopted. Assessments were carried out while participants (n=49) wore their dentures first without then with adhesives. Computerized occlusal analysis using the T-Scan III system was conducted to perform baseline computer-guided occlusal adjustment for conventionally fabricated dentures. Retention and stability assessment using the modified Kapur index and recording of OT and DT-right and DT-left values using the T-Scan III were subsequently carried out for all dentures, first without adhesives and then after application of adhesive. All T-Scan procedures were carried out by the same clinician. Wilcoxon signed-rank test was used to analyze the Kapur index scores and occlusal parameters (α=.05). Stability and retention of conventional dentures ranged initially from good to very good. However, adhesive application resulted in significant improvement (P<.001) in stability and retention and a significant decrease in duration of all occlusal parameters (OT [P=.003], DT-right [P=.003], and DT-left [P=.008]). Adhesives significantly decreased OT and DT durations in initially well-fitting complete dentures with fairly well balanced occlusion, and further enhanced denture stability and occlusal contact simultaneity. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. The Medina Embolic Device: Karolinska experience.

    PubMed

    Bhogal, P; Brouwer, P A; Yeo, L; Svensson, M; Söderman, M

    2018-02-01

    Background The aim of this study was to report our single centre experience with the Medina Embolic Device (MED). Methods We performed a retrospective analysis of prospectively collected data to identify all patients treated with the MED. A total of 14 aneurysms (non-consecutive), in 13 patients, were treated including one ruptured and one partially thrombosed aneurysm. Fundus diameter was ≥5 mm in all cases. We evaluated the angiographic appearances, the clinical status, complications, and the need for adjunctive devices or repeat treatments. Results Aneurysm location was cavernous internal carotid artery (ICA; n = 1), supraclinoid ICA ( n = 1), terminal ICA ( n = 2), anterior communicating artery (AComA; n = 4), A2-3 ( n = 1), M1-2 junction ( n = 1), posterior communicating artery (PComA; n = 1), superior cerebellar artery (SCA; n = 1), and basilar tip ( n = 2). The average aneurysm fundus size was 8.6 mm (range 7-10 mm) and average neck size 3.75 mm (range 1.9-6.9 mm). Immediate angiographic results were modified Raymond-Roy occlusion classification (mRRC) I n = 2, mRRC II n = 1, mRRC IIIa n = 2, mRRC IIIb n = 2, the remaining 7 aneurysms showed complete opacification. At follow-up angiography (mean 5 months) mRRC I n = 5, mRRC II n = 5, mRRC IIIa n = 3, and persistent filling was seen in 1 aneurysm. Overall, four patients had repeat treatment and one is pending further treatment. Of the aneurysms treated with more than one MED, 75% showed complete occlusion at 6-month follow up whereas only one aneurysm treated with a single device showed complete occlusion. Overall, three patients had temporary complications and there were no deaths. Conclusions The MED is an intra-saccular flow-diverting device with satisfactory angiographic results and an acceptable safety profile. Use of a single MED cannot be recommended and further longer term studies are needed prior to widespread clinical use.

  13. An Endovascular Cannulation Needle with an Internal Wire for the Fragmentation of Thrombi in Retinal Vein Occlusion

    PubMed Central

    Asami, Tetsu; Kaneko, Hiroki; Miyake, Kensaku; Ota, Ichiro; Miyake, Goichiro; Kato, Seiichi; Yasuda, Shunsuke; Iwase, Takeshi; Ito, Yasuki; Terasaki, Hiroko

    2016-01-01

    Purpose We report a newly developed device to fragment thrombi in retinal vein occlusion. Methods The new instrument consists of a 23-gauge (G) pipe and a 37-G needle with an internal wire. A total of 40 porcine eyes were used; 20 eyes for experiments in the branch retinal vein (BRV group) and 20 eyes for experiments in the central retinal vein (CRV group). We placed 25-G 3-port trocars, and core vitrectomy was performed. Another 23-G scleral incision was performed for insertion of the needle. The needle pierced the retinal vein at a distance of three- to four- or one-disc diameters from the optic disc (BRV or CRV group, respectively), and the internal wire was advanced toward the disc. The success rates of needle piercing and cannulation of the internal wire were recorded in each group. In the CRV group, the cannulation was deemed successful when the tip reached inside the optic disc. Real-time optical coherence tomography imaging also was performed using the Zeiss Rescan 700 device in porcine eyes. Histologic examination of the retinal vessel inserted with the internal wire was performed. Results The success rates of needle piercing into the BRV and CRV were 85% and 95%, respectively. The success rates of cannulation of the internal wire into the BRV and CRV were 85% and 0%, respectively. The process of cannulation was recorded successfully with the Rescan 700. Histologic examination showed no damages to the endothelial cell layer. Conclusions The needle and internal wire intended to be used for recanalization of BRV occlusion were successfully pierced and cannulated into the BRV. Translational Relevance This newly developed device could become a treatment modality for retinal vein occlusion to fragment thrombi that present treatment methods cannot reach and remove directly. PMID:27730009

  14. Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions

    PubMed Central

    Choi, Sulki

    2017-01-01

    PURPOSE The goal of this study was to evaluate the fracture resistances of various monolithic crowns fabricated by computer-aided design and computer-aided manufacturing (CAD/CAM) with different thickness. MATERIALS AND METHODS Test dies were fabricated as mandibular molar forms with occlusal reductions using CAD/CAM. With different occlusal thickness (1.0 or 1.5 mm), a polymer-infiltrated ceramic network (Enamic, EN), and zirconia-reinforced lithium silicate (Suprinity, SU and Celtra-Duo, CD) were used to fabricate molar crowns. Lithium disilicate (e.max CAD, EM) crowns (occlusal: 1.5 mm) were fabricated as control. Seventy crowns (n=10 per group) were bonded to abutments and stored in water for 24 hours. A universal testing machine was used to apply load to crown until fracture. The fractured specimens were examined with a scanning electron microscopy. RESULTS The type of ceramics and the occlusal thickness showed a significant interaction. With a recommended thickness (1.5 mm), the SU revealed the mean load similar to the EM, higher compared with those of the EN and CD. The fracture loads in a reduced thickness (1.0 mm) were similar among the SU, CD, and EN. The mean fracture load of the SU and CD enhanced significantly when the occlusal thickness increased, whereas that of the EN did not. CONCLUSION The fracture loads of monolithic crowns were differently influenced by the changes in occlusal thickness, depending on the type of ceramics. Within the limitations of this study, all the tested crowns withstood the physiological masticatory loads both at the recommended and reduced occlusal thickness. PMID:29279761

  15. Autonomous Method and System for Minimizing the Magnitude of Plasma Discharge Current Oscillations in a Hall Effect Plasma Device

    NASA Technical Reports Server (NTRS)

    Hruby, Vladimir (Inventor); Demmons, Nathaniel (Inventor); Ehrbar, Eric (Inventor); Pote, Bruce (Inventor); Rosenblad, Nathan (Inventor)

    2014-01-01

    An autonomous method for minimizing the magnitude of plasma discharge current oscillations in a Hall effect plasma device includes iteratively measuring plasma discharge current oscillations of the plasma device and iteratively adjusting the magnet current delivered to the plasma device in response to measured plasma discharge current oscillations to reduce the magnitude of the plasma discharge current oscillations.

  16. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    NASA Astrophysics Data System (ADS)

    Morais, A. P.; Pino, A. V.; Souza, M. N.

    2016-08-01

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  17. Influence of Slippery Pacemaker Leads on Lead-Induced Venous Occlusion

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Bhatia, Sagar; Obenauf, Dayna; Resse, Max; Esmaily-Moghadam, Mahdi; Feinstein, Jeffrey; Pak, On Shun

    2016-11-01

    The use of medical devices such as pacemakers and implantable cardiac defibrillators have become commonplace to treat arrhythmias. Pacing leads with electrodes are used to send electrical pulses to the heart to treat either abnormally slow heart rates, or abnormal rhythms. Lead induced vessel occlusion, which is commonly seen after placement of pacemaker or ICD leads, may result in lead malfunction and/or SVC syndrome, and makes lead extraction difficult. The association between the anatomic locations at risk for thrombosis and regions of venous stasis have been reported previously. The computational studies reveal obvious flow stasis in the proximity of the leads, due to the no-slip boundary condition imposed on the lead surface. With the advent of recent technologies capable of creating slippery surfaces that can repel complex fluids including blood, we explore computationally how local flow structures may be altered in the regions around the leads when the no-slip boundary condition on the lead surface is relaxed using various slip lengths. The findings evaluate the possibility of mitigating risks of lead-induced thrombosis and occlusion by implementing novel surface conditions (i.e. theoretical coatings) on the leads.

  18. Recanalization of Acute and Subacute Femoropopliteal Artery Occlusions with the Rotarex Catheter: One Year Follow-up, Single Center Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duc, Sylvain R., E-mail: Sylvain.duc@balgrist.ch; Schoch, Eric; Pfyffer, Markus

    2005-06-15

    Purpose:To assess the efficacy and safety of a new rotational catheter for percutaneous removal of fresh and organized thrombi in the femoropopliteal artery.Methods:Forty-one limbs in 38 patients (age 56-90 years, mean 75.6 years) with acute, subacute or chronic femoropopliteal occlusions of 1-180 days' duration (mean 31.6 days) were treated with the Rotarex device. The Fontaine stage was mainly IIB (Rutherford 2-3, 22 patients) or III (Rutherford 4, 14 patients). The length of occlusion varied from 2 to 35 cm (mean 13.1 cm). After recanalization percutaneous transluminal angioplasty (PTA) was performed if there was a residual stenosis of >25%. Patients weremore » followed up with color Doppler ultrasound at 48 hr and clinically with Doppler pressures and oscillometry at 3, 6, and 12 months.Results:After an average of two passages with the Rotarex catheter all but two limbs required PTA for residual stenosis >25%. Five patients needed additional stenting. Major complications were one groin hematoma requiring blood transfusion and one arteriovenous fistula spontaneously thrombosing after unsuccessful primary prolonged balloon dilation. Distal embolizations occurred in 10 patients; 6 clinically relevant emboli were aspirated. All occlusions were technically successfully recanalised there were 2 early reocclusions after 1 day and two at 2 weeks. Brachial-ankle indices improved from an average of 0.41 before to 0.93 after recanalization. Primary and secondary patency rates were 62% / 84% after 6 months and 39% / 68% after 1 year. The amputation-free survival at 12 months was 100%.Conclusion:The Rotarex mechanical thrombectomy device is an efficient, quick, easy to handle, and safe tool for the treatment of acute, subacute or even chronic peripheral arterial thromboembolic occlusions. It can be used for short or long occlusions with equal success, provided the obstruction is not heavily calcified and has been safely passed with a guidewire first.« less

  19. Nonlinear time dependence of dark current in charge-coupled devices

    NASA Astrophysics Data System (ADS)

    Dunlap, Justin C.; Bodegom, Erik; Widenhorn, Ralf

    2011-03-01

    It is generally assumed that charge-coupled device (CCD) imagers produce a linear response of dark current versus exposure time except near saturation. We found a large number of pixels with nonlinear dark current response to exposure time to be present in two scientific CCD imagers. These pixels are found to exhibit distinguishable behavior with other analogous pixels and therefore can be characterized in groupings. Data from two Kodak CCD sensors are presented for exposure times from a few seconds up to two hours. Linear behavior is traditionally taken for granted when carrying out dark current correction and as a result, pixels with nonlinear behavior will be corrected inaccurately.

  20. Volumetric ambient occlusion for real-time rendering and games.

    PubMed

    Szirmay-Kalos, L; Umenhoffer, T; Toth, B; Szecsi, L; Sbert, M

    2010-01-01

    This new algorithm, based on GPUs, can compute ambient occlusion to inexpensively approximate global-illumination effects in real-time systems and games. The first step in deriving this algorithm is to examine how ambient occlusion relates to the physically founded rendering equation. The correspondence stems from a fuzzy membership function that defines what constitutes nearby occlusions. The next step is to develop a method to calculate ambient occlusion in real time without precomputation. The algorithm is based on a novel interpretation of ambient occlusion that measures the relative volume of the visible part of the surface's tangent sphere. The new formula's integrand has low variation and thus can be estimated accurately with a few samples.

  1. Varying face occlusion detection and iterative recovery for face recognition

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Hu, Zhengping; Sun, Zhe; Zhao, Shuhuan; Sun, Mei

    2017-05-01

    In most sparse representation methods for face recognition (FR), occlusion problems were usually solved via removing the occlusion part of both query samples and training samples to perform the recognition process. This practice ignores the global feature of facial image and may lead to unsatisfactory results due to the limitation of local features. Considering the aforementioned drawback, we propose a method called varying occlusion detection and iterative recovery for FR. The main contributions of our method are as follows: (1) to detect an accurate occlusion area of facial images, an image processing and intersection-based clustering combination method is used for occlusion FR; (2) according to an accurate occlusion map, the new integrated facial images are recovered iteratively and put into a recognition process; and (3) the effectiveness on recognition accuracy of our method is verified by comparing it with three typical occlusion map detection methods. Experiments show that the proposed method has a highly accurate detection and recovery performance and that it outperforms several similar state-of-the-art methods against partial contiguous occlusion.

  2. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions.

    PubMed

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-05-23

    BACKGROUND The GuideLiner catheter extension device is a monorail-type "Child" support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). CASE REPORT We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guidewires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. CONCLUSIONS The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion.

  3. Current-driven domain wall motion based memory devices: Application to a ratchet ferromagnetic strip

    NASA Astrophysics Data System (ADS)

    Sánchez-Tejerina, Luis; Martínez, Eduardo; Raposo, Víctor; Alejos, Óscar

    2018-04-01

    Ratchet memories, where perpendicular magnetocristalline anisotropy is tailored so as to precisely control the magnetic transitions, has been recently proven to be a feasible device to store and manipulate data bits. For such devices, it has been shown that the current-driven regime of domain walls can improve their performances with respect to the field-driven one. However, the relaxing time required by the traveling domain walls constitutes a certain drawback if the former regime is considered, since it results in longer device latencies. In order to speed up the bit shifting procedure, it is demonstrated here that the application of a current of inverse polarity during the DW relaxing time may reduce such latencies. The reverse current must be sufficiently high as to drive the DW to the equilibrium position faster than the anisotropy slope itself, but with an amplitude sufficiently low as to avoid DW backward shifting. Alternatively, it is possible to use such a reverse current to increase the proper range of operation for a given relaxing time, i.e., the pair of values of the current amplitude and pulse time that ensures single DW jumps for a certain latency time.

  4. Dental cervical lesions associated with occlusal erosion and attrition.

    PubMed

    Khan, F; Young, W G; Shahabi, S; Daley, T J

    1999-09-01

    Acid demineralization of teeth causes occlusal erosion and attrition, and shallow and wedge-shaped cervical lesions putatively involving abfraction. From 250 patients with tooth wear, 122 with cervical lesions were identified. From epoxy resin replicas of their dentitions, associations of occlusal attrition or erosion or no wear with cervical lesions were recorded at 24 tooth sites (total 2928 sites). Criteria used to discriminate occlusal attrition from erosion, and shallow from grooved, wedge-shaped or restored cervical lesions were delineated by scanning electron microscopy. A 96 per cent association was found between occlusal and cervical pathology. Shallow cervical lesions were more commonly found in association with occlusal erosion. Wedge-shaped lesions were found equally commonly in association with occlusal erosion, as with attrition. Grooved and restored cervical lesions were uncommon. Differences were appreciated in the associations within incisor, canine, premolar and molar tooth sites which related more to the site-specificity of dental erosion than to attrition from occlusal forces. Non-carious lesions on teeth then have multifactorial aetiology and pathogenesis in which erosion and salivary protection play central roles. Dentists should primarily consider erosion in the diagnosis, prevention and treatment of tooth wear.

  5. Optical effects of shadow masks on short circuit current of organic photovoltaic devices.

    PubMed

    Lin, Chi-Feng; Lin, Bing-Hong; Liu, Shun-Wei; Hsu, Wei-Feng; Zhang, Mi; Chiu, Tien-Lung; Wei, Mau-Kuo; Lee, Jiun-Haw

    2012-03-21

    In this paper, we have employed different shadow masks attached on top of organic photovoltaic (OPV) devices to study the optical effects of the former on the short circuit current (J(SC)). To rule out possible lateral electrical conduction and simplify the optical effects inside the device, a small-molecular heterojunction OPV device with a clear donor/acceptor interface was employed with a hole extraction layer exhibiting high resistance intentionally. Careful calibration with a shadow mask was employed. By attaching two layers of opaque masks in combination with a suitable holder design to shield the light from the edges and backside, the value of J(SC) approached that of the dark current, even under 1-sun radiation. With different illumination areas, we found that the photons illuminating the non-active region of the device contributed to 40% of the J(SC) by optical effect within the width of about 1 mm around the active region. When illuminating the non-active area with 12 mm to the active area, a 5.6 times improvement in the J(SC) was observed when the incident angle was 75°. With the introduction of a microstructured film onto the OPV device and an increase in the reflection from the non-active region, a 15% enhancement of the J(SC) compared to the control device was achieved.

  6. RETINAL VEIN OCCLUSIONS, FROM BASICS TO THE LATEST TREATMENT.

    PubMed

    Ho, Mary; Liu, David T L; Lam, Dennis S C; Jonas, Jost B

    2016-03-01

    To review the pathophysiology, diagnosis, and updated treatments of retinal vein occlusions (RVOs). A review of the literature was performed, focusing on the epidemiology, pathophysiology, diagnosis, and treatments (including both medical and surgical treatments) of RVO. Based on this review, a comprehensive overview was provided regarding the topic of RVO and focused on recent treatment updates. Retinal vein occlusions have an age- and sex-standardized prevalence of 5.20 per 1,000 for any RVO, 4.42 per 1,000 for branch RVO, 0.80 per 1,000 for central RVO. Worldwide, an estimated 16.4 million adults are affected by RVOs, with 2.5 million affected by central RVO and 13.9 million affected by branch RVO. Retinal vein occlusion is recognized as an important cause of blindness and the diagnostic approaches and treatment options for RVO are reviewed and reported. The current treatment options including medical treatments (bevacizumab, ranibizumab, aflibercept, triamcinolone, and dexamethasone implants) and surgical alternatives were reviewed and reported with summaries on the corresponding strength of evidence. Despite the understanding of this disease entity, challenges persist in the long-term treatment of RVO-related complications and visual loss. This review provided a detailed summary on the rationality and efficacy of recently developed treatment regimes and evaluated the potential benefit of combination therapy.

  7. A Quantitative and Qualitative Evaluation of an Automatic Occlusion Device for Tracheoesophageal Speech: The Provox FreeHands HME

    ERIC Educational Resources Information Center

    Hamade, Rachel; Hewlett, Nigel; Scanlon, Emer

    2006-01-01

    This study aimed to evaluate a new automatic tracheostoma valve: the Provox FreeHands HME (manufactured by Atos Medical AB, Sweden). Data from four laryngectomee participants using automatic and also manual occlusion were subjected to acoustic and perceptual analysis. The main results were a significant decrease, from the manual to automatic…

  8. Woven Endobridge (WEB) device for endovascular treatment of complex unruptured aneurysms-a single center experience.

    PubMed

    Lescher, Stephanie; du Mesnil de Rochemont, Richard; Berkefeld, Joachim

    2016-04-01

    The introduction of the Woven Endobridge (WEB) device increases the feasibility of endovascular treatment of wide-neck bifurcation aneurysms with limitations given by currently available sizes and shapes of the device. Parallel to other studies, we used the new device for selected patients who were no optimal candidates for established techniques like neurosurgical clipping or endovascular coiling. We aimed to report the angiographic and clinical results of WEB implantations or combinations between WEB and coiling or intracranial stents. We reviewed the records of n = 23 interventions in 22 patients with unruptured wide-neck aneurysms (UIA) who were assigned for aneurysm treatment with the use of the WEB or adjunctive techniques. Interventional procedures and clinical and angiographic outcomes are reported for the periprocedural phase and in mid-term FU. Of the included 22 patients, six patients needed additional coiling, intracranial stenting, or implantation of a flow diverter. WEB implantation was technically feasible in 22 out of the 23 interventions. Follow-up angiographic imaging proved total or subtotal occlusion of the aneurysm in 19 of 22 cases. Two minor recurrences remained stable during a period of 15 months. One patient with a partially thrombosed giant MCA aneurysm had a major recurrence and was retreated with a second WEB in combination with coiling. Despite of unfavorable anatomic conditions, broad-based and large UIA endovascular treatment with the WEB and adjunctive techniques was feasible with a low risk of complications and promising occlusion rates in mid-term follow-up.

  9. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morais, A. P.; Salgado de Oliveira University, Marechal Deodoro Street, 217 – Centro, Niterói, Rio de Janeiro; Pino, A. V.

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C andmore » α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.« less

  10. Part-time occlusion therapy for amblyopia in older children

    PubMed Central

    Singh, Inderpreet; Sachdev, Nishant; Kaushik, Sushmita

    2008-01-01

    Aim: To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Materials and Methods: Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Statistical Analysis: Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. Results: All four groups showed significant visual improvement after 18 weeks of occlusion therapy (P<0.001). Seventy-three (73%) of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups (P=0.083). However, in severe amblyopia (vision 20/100 or worse), six hours (P=0.048) and full-time occlusion (P=0.027) treatment were significantly more effective than two hours occlusion. Conclusion: All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy. PMID:18974515

  11. Part-time occlusion therapy for amblyopia in older children.

    PubMed

    Singh, Inderpreet; Sachdev, Nishant; Brar, Gagandeep S; Kaushik, Sushmita

    2008-01-01

    To compare the efficacy of part-time versus full-time occlusion for treatment of amblyopia in children aged 7-12 years. Prospective interventional case series. One hundred children between 7-12 years of age with anisometropic (57), strabismic (25) and mixed (18) unilateral amblyopia were randomized (simple randomization) into four groups (25 each) to receive two hours, four hours, six hours or full-time occlusion therapy. Children were regularly followed up at six-weekly intervals for a minimum of three visits. Intragroup visual improvement was analyzed using paired t-test while intergroup comparisons were done using ANOVA and unpaired t-test. All four groups showed significant visual improvement after 18 weeks of occlusion therapy ( P < 0.001). Seventy-three (73%) of the total 100 eyes responded to amblyopia therapy with 11 eyes (44%), 17 eyes (68%), 22 eyes (88%) and 23 eyes (92%) being amblyopia responders in the four groups respectively, with the least number of responders in the two hours group. In mild to moderate amblyopia (vision 20/30 to 20/80), there was no significant difference in visual outcome among the four groups ( P =0.083). However, in severe amblyopia (vision 20/100 or worse), six hours ( P =0.048) and full-time occlusion ( P =0.027) treatment were significantly more effective than two hours occlusion. All grades of part-time occlusion are comparable to full-time occlusion in effectiveness of treatment for mild to moderate amblyopia in children between 7-12 years of age unlike in severe amblyopia, where six hours and full-time occlusion were more effective than two hours occlusion therapy.

  12. Occlusal plane location in edentulous patients: a review.

    PubMed

    Shetty, Sanath; Zargar, Nazia Majeed; Shenoy, Kamalakanth; Rekha, V

    2013-09-01

    Occlusal plane orientation is an important factor in the construction of a complete denture. Occlusal plane could be oriented using landmarks in the mandibular arch as well as in the maxillary arch. In the mandibular arch there are few landmarks which could be used to orient the occlusal plane like the retromolar pad, corner of the lips (lower lip length) whereas the maxillary arch has a number of landmarks, of which the ala-tragal line is the most commonly used and the same being the most controversial. In the following article different landmarks and its accuracy for orientating the occlusal plane in an edentulous subject as studied by various authors has been discussed.

  13. Osteogenesis imperfecta with right renal artery occlusion

    PubMed Central

    Vaish, Arvind Kumar; Kumar, Nitin; Jain, Nirdesh; Agarwal, Abhishek

    2012-01-01

    We here report a case of osteogenesis imperfecta who presented with severe hypertension and left ventricular failure and had right renal artery occlusion. The case is very interesting as renal artery occlusion has not been reported earlier in osteogenesis imperfecta. PMID:22962392

  14. Probing of barrier induced deviations in current-voltage characteristics of polymer devices by impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Khan, Motiur Rahman; Rao, K. S. R. Koteswara; Menon, R.

    2017-05-01

    Temperature dependent current-voltage measurements have been performed on poly(3-methylthiophene) based devices in metal/polymer/metal geometry in temperature range 90-300 K. Space charge limited current (SCLC) controlled by exponentially distributed traps is observed at all the measured temperatures at intermediate voltage range. At higher voltages, trap-free SCLC is observed at 90 K only while slope less than 2 is observed at higher temperatures which is quiet unusual in polymer devices. Impedance measurements were performed at different bias voltages. The unusual behavior observed in current-voltage characteristics is explained by Cole-Cole plot which gives the signature of interface dipole on electrode/polymer interface. Two relaxation mechanisms are obtained from the real part of impedance vs frequency spectra which confirms the interface related phenomena in the device

  15. Calculation of induced current densities for humans by magnetic fields from electronic article surveillance devices

    NASA Astrophysics Data System (ADS)

    Gandhi, Om P.; Kang, Gang

    2001-11-01

    This paper illustrates the use of the impedance method to calculate the electric fields and current densities induced in millimetre resolution anatomic models of the human body, namely an adult and 10- and 5-year-old children, for exposure to nonuniform magnetic fields typical of two assumed but representative electronic article surveillance (EAS) devices at 1 and 30 kHz, respectively. The devices assumed for the calculations are a solenoid type magnetic deactivator used at store checkouts and a pass-by panel-type EAS system consisting of two overlapping rectangular current-carrying coils used at entry and exit from a store. The impedance method code is modified to obtain induced current densities averaged over a cross section of 1 cm2 perpendicular to the direction of induced currents. This is done to compare the peak current densities with the limits or the basic restrictions given in the ICNIRP safety guidelines. Because of the stronger magnetic fields at lower heights for both the assumed devices, the peak 1 cm2 area-averaged current densities for the CNS tissues such as the brain and the spinal cord are increasingly larger for smaller models and are the highest for the model of the 5-year-old child. For both the EAS devices, the maximum 1 cm2 area-averaged current densities for the brain of the model of the adult are lower than the ICNIRP safety guideline, but may approach or exceed the ICNIRP basic restrictions for models of 10- and 5-year-old children if sufficiently strong magnetic fields are used.

  16. Calculation of induced current densities for humans by magnetic fields from electronic article surveillance devices.

    PubMed

    Gandhi, O P; Kang, G

    2001-11-01

    This paper illustrates the use of the impedance method to calculate the electric fields and current densities induced in millimetre resolution anatomic models of the human body, namely an adult and 10- and 5-year-old children, for exposure to nonuniform magnetic fields typical of two assumed but representative electronic article surveillance (EAS) devices at 1 and 30 kHz, respectively. The devices assumed for the calculations are a solenoid type magnetic deactivator used at store checkouts and a pass-by panel-type EAS system consisting of two overlapping rectangular current-carrying coils used at entry and exit from a store. The impedance method code is modified to obtain induced current densities averaged over a cross section of 1 cm2 perpendicular to the direction of induced currents. This is done to compare the peak current densities with the limits or the basic restrictions given in the ICNIRP safety guidelines. Because of the stronger magnetic fields at lower heights for both the assumed devices, the peak 1 cm2 area-averaged current densities for the CNS tissues such as the brain and the spinal cord are increasingly larger for smaller models and are the highest for the model of the 5-year-old child. For both the EAS devices, the maximum 1 cm2 area-averaged current densities for the brain of the model of the adult are lower than the ICNIRP safety guideline, but may approach or exceed the ICNIRP basic restrictions for models of 10- and 5-year-old children if sufficiently strong magnetic fields are used.

  17. A comparative study of percutaneous atherectomy for femoropopliteal arterial occlusive disease.

    PubMed

    Gu, Yongquan; Malas, Mahmoud B; Qi, Lixing; Guo, Lianrui; Guo, Jianming; Yu, Hengxi; Tong, Zhu; Gao, Xixiang; Zhang, Jian; Wang, Zhonggao

    2017-08-01

    SilverHawk™ directional atherectomy has been used to treat more than 300 thousand cases of lower extremity atherosclerotic occlusive disease in the world since it was approved by FDA in 2003. This study aimed to analyze the safety and effectiveness of symptomatic femoral popliteal atherosclerotic disease treated by directional atherectomy (DA). Clinical data of all consecutive patients treated with percutaneous atherectomy utilizing the SilverHawk™ plaque excision was retrospectively analyzed. The anatomic criteria of the atherosclerotic lesions were divided into four types: type I stenosis; type II occlusion; type III in-stent restenosis; type IV stent occlusion. There were 160 patients treated during the study period. Intermittent claudication in 75 patients (47%), rest pain in 55 patients (34.5%) and tissue loss in 30 patients (18.5%). The number of patients was 72, 15, 49 and 24 in type I, II, III and IV lesions, respectively. Technical success rate was 98.6%, 93.3%, 97.9% and 91.7% in type I, II, III and IV lesions, respectively. Debris of intimal plaque was captured by protection device in 92 patients (71.3%). The mean follow-up period was 23.5±10.4 months. Restenosis rate of type I to IV lesions was 21%, 36%, 36% and 40% respectively. Restenosis rate in type I lesion was significantly lower than that in type III and IV lesions (P<0.05). Patients with tissue loss responded to revascularization as follow: type I, 11/13 healed or reduced (84.6%), type II, 3/3 patients improved (100%), type III, 5/6 patients improved (83.3%) and type IV 4/4 healed (100%). In type IV group, four patients had in-stent thrombosis found by postoperative Duplex ultrasonography. They all underwent DA after catheter-directed thrombolysis with good angiographic results. Percutaneous DA is safe and effective for both de-novo atherosclerotic and in-stent stenotic or occlusive lesions. Thrombolysis before plaque excision is recommended in case of in-stenting thrombosis.

  18. Principle and experimental investigation of current-driven negative-inductance superconducting quantum interference device

    NASA Astrophysics Data System (ADS)

    Li, Hao; Liu, Jianshe; Zhang, Yingshan; Cai, Han; Li, Gang; Liu, Qichun; Han, Siyuan; Chen, Wei

    2017-03-01

    A negative-inductance superconducting quantum interference device (nSQUID) is an adiabatic superconducting logic device with high energy efficiency, and therefore a promising building block for large-scale low-power superconducting computing. However, the principle of the nSQUID is not that straightforward and an nSQUID driven by voltage is vulnerable to common mode noise. We investigate a single nSQUID driven by current instead of voltage, and clarify the principle of the adiabatic transition of the current-driven nSQUID between different states. The basic logic operations of the current-driven nSQUID with proper parameters are simulated by WRspice. The corresponding circuit is fabricated with a 100 A cm-2 Nb-based lift-off process, and the experimental results at low temperature confirm the basic logic operations as a gated buffer.

  19. Occlusal contact of fixed implant prostheses using functional bite impression technique.

    PubMed

    Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2015-02-01

    Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.

  20. Design of all-optical, hot-electron current-direction-switching device based on geometrical asymmetry

    PubMed Central

    Kumarasinghe, Chathurangi S.; Premaratne, Malin; Gunapala, Sarath D.; Agrawal, Govind P.

    2016-01-01

    We propose a nano-scale current-direction-switching device(CDSD) that operates based on the novel phenomenon of geometrical asymmetry between two hot-electron generating plasmonic nanostructures. The proposed device is easy to fabricate and economical to develop compared to most other existing designs. It also has the ability to function without external wiring in nano or molecular circuitry since it is powered and controlled optically. We consider a such CDSD made of two dissimilar nanorods separated by a thin but finite potential barrier and theoretically derive the frequency-dependent electron/current flow rate. Our analysis takes in to account the quantum dynamics of electrons inside the nanorods under a periodic optical perturbation that are confined by nanorod boundaries, modelled as finite cylindrical potential wells. The influence of design parameters, such as geometric difference between the two nanorods, their volumes and the barrier width on quality parameters such as frequency-sensitivity of the current flow direction, magnitude of the current flow, positive to negative current ratio, and the energy conversion efficiency is discussed by considering a device made of Ag/TiO2/Ag. Theoretical insight and design guidelines presented here are useful for customizing our proposed CDSD for applications such as self-powered logic gates, power supplies, and sensors. PMID:26887286

  1. Design of all-optical, hot-electron current-direction-switching device based on geometrical asymmetry.

    PubMed

    Kumarasinghe, Chathurangi S; Premaratne, Malin; Gunapala, Sarath D; Agrawal, Govind P

    2016-02-18

    We propose a nano-scale current-direction-switching device(CDSD) that operates based on the novel phenomenon of geometrical asymmetry between two hot-electron generating plasmonic nanostructures. The proposed device is easy to fabricate and economical to develop compared to most other existing designs. It also has the ability to function without external wiring in nano or molecular circuitry since it is powered and controlled optically. We consider a such CDSD made of two dissimilar nanorods separated by a thin but finite potential barrier and theoretically derive the frequency-dependent electron/current flow rate. Our analysis takes in to account the quantum dynamics of electrons inside the nanorods under a periodic optical perturbation that are confined by nanorod boundaries, modelled as finite cylindrical potential wells. The influence of design parameters, such as geometric difference between the two nanorods, their volumes and the barrier width on quality parameters such as frequency-sensitivity of the current flow direction, magnitude of the current flow, positive to negative current ratio, and the energy conversion efficiency is discussed by considering a device made of Ag/TiO2/Ag. Theoretical insight and design guidelines presented here are useful for customizing our proposed CDSD for applications such as self-powered logic gates, power supplies, and sensors.

  2. The anterior component of occlusal force revisited: direct measurement and theoretical considerations.

    PubMed

    Al Qassar, Sarmad S Salih; Mavragani, Maria; Psarras, Vasilis; Halazonetis, Demetrios J

    2016-04-01

    The anterior component of occlusal force (ACF), considered to result from the mesial inclination of teeth relative to the occlusal plane, has been estimated by indirectly measuring contact point tightness (CPT) through interproximal insertion of metal strips. ACF has been observed concurrently with a posterior component, whose theoretical origin is difficult to explain. Evaluate ACF by measuring CPT directly, and integrate current data to propose a theoretical basis for ACF. The sample comprised 14 females (age: 22.3±2.8) and 16 males (age: 20.8±2.5). Our device consisted of two force sensors: one for measuring maximum bite force (MBF) (overall thickness: 4mm), and one for measuring CPT directly (0.2mm thick), inserted between the lower first molar and second premolar. ACF was computed as the difference in CPT between the biting (at 75 per cent of MBF) and non-biting conditions. Averages of MBF, CPT, and ACF were 666.67 [standard deviation (SD): 36.06], 6.74 (SD: 1.17), and 20.59 (SD: 4.60) N, respectively. ACF, CPT, and MBF were higher in males by approximately 28, 18 and 7 per cent, respectively. A positive correlation was observed between ACF and MBF (R (2): 0.64). CPT was also significantly correlated to MBF (R (2): 0.40). Biomechanical analysis indicates that previously offered explanations do not unriddle the concurrent increase of CPT at anterior and posterior contact points. ACF was related to bite force by a logarithmic model. We speculate that CPT increases during biting through a combination of mesial tipping of teeth and mandibular bending. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  3. Does compliance with amblyopia management improve following supervised occlusion treatment?

    PubMed

    El-Ghrably, I A; Longville, D; Gnanaraj, L

    2007-01-01

    To demonstrate improvement in compliance following supervised occlusion therapy for amblyopia in children who had failed to respond to outpatient treatment. Retrospective review of the visual outcome of 30 children who were admitted to an ophthalmology ward for 1-day intensive supervised occlusion. These children had documented poor compliance and previously failed to respond to the outpatient occlusion treatment. During their stay a trained ophthalmology nurse educated parents regarding amblyopia and the benefits of occlusion therapy. Visual acuity (VA) of the amblyopic and fellow eyes was recorded on admission, discharge, and at each subsequent visit. The compliance was recorded from parent's history and also indirectly by noticing improvement in vision. The mean supervised occlusion was 7.4 hours (range 4-12 hours). The compliance with occlusion therapy improved in 23 children (77%) after discharge. The mean duration of occlusion after discharge improved to 4 hours (range 1-12 hours). The mean follow-up was 18 months (range 4-24 months). Though there was no dramatic improvement in VA at discharge there was a statistically significant improvement in VA between admission and last recorded VA (p<0.0001). Of the 23 children who were compliant with occlusion following discharge, 21 (91%) gained at least one line of acuity in their amblyopic eye on the last assessment of their VA and five of them achieved 6/12. Of the seven children who did not comply with occlusion following discharge, only one patient gained one line improvement in his amblyopic eye. This study shows that supervised occlusion treatment and parental education was effective in children who had initially failed traditional outpatient treatment.

  4. [Cilioretinal artery occlusion and central retinal vein occlusion complicating hyperhomocysteinemia: a case report].

    PubMed

    Berkani, Z; Kitouni, Y; Belhadj, A; Sifi, K; Abbadi, N; Bellatrache, C; Hartani, D; Kherroubi, R

    2013-09-01

    Hyperhomocysteinemia is known to be a risk factor in both retinal artery and retinal vein occlusions. We report the case of a young patient with combined occlusion of the cilioretinal artery and the central retinal vein due to hyperhomocysteinemia. A 23-year-old patient without significant medical history, presented for sudden, painless visual loss in the right eye. Ophthalmologic examination revealed best-corrected visual acuity of the right eye 8/10 P2, and 10/10 P2 on the left. Anterior segment exam was normal in both eyes, while the right fundus revealed white, ischemic edema, centered around a cilioretinal artery, sparing the fovea, with some hemorrhagic spots and disc edema. Fluorescein angiography confirmed delayed filling of the right cilioretinal artery and revealed a normal disc on the left. Two weeks later, the clinical picture had evolved into a right ischemic CRVO, confirmed by a second angiogram, with a decrease in visual acuity to 3/10. A work-up was performed, including: a full lipid profile, serum electrolytes, ESR, CRP, a complete blood count (leukocytes, platelets, hemoglobin were normal), a coagulation work-up (PT, PTT, protein C, protein S, antithrombin III, factor V Leiden were normal), ANCA, antiphospholipid antibodies and antinuclear antibodies were negative, and finally cardiology studies (cardiac echo, carotid Doppler) and neurology (brain MRI) were ordered and came back normal. Otherwise, plasma homocysteine was moderately high on two samples, at 18.3 μmol/L and 17.78 μmol/L. Thyroid and renal work-ups were ordered. Urgent PRP was performed, and vitamin therapy (vitB12, vitB6, folic acid) was instituted. The subsequent course was remarkable for recovery of visual acuity to 10/10, P2 with persistence of an inferior altitudinal central scotoma. MTHFR C677T polymorphism was negative. Retinal vascular occlusions (RVO) are serious events, which require investigation for underlying systemic disease, which can be life-threatening. The clinical

  5. Current and Perspective Applications of Dense Plasma Focus Devices

    NASA Astrophysics Data System (ADS)

    Gribkov, V. A.

    2008-04-01

    Dense Plasma Focus (DPF) devices' applications, which are intended to support the main-stream large-scale nuclear fusion programs (NFP) from one side (both in fundamental problems of Dense Magnetized Plasma physics and in its engineering issues) as well as elaborated for an immediate use in a number of fields from the other one, are described. In the first direction such problems as self-generated magnetic fields, implosion stability of plasma shells having a high aspect ratio, etc. are important for the Inertial Confinement Fusion (ICF) programs (e.g. as NIF), whereas different problems of current disruption phenomenon, plasma turbulence, mechanisms of generation of fast particles and neutrons in magnetized plasmas are of great interest for the large devices of the Magnetic Plasma Confinement—MPC (e.g. as ITER). In a sphere of the engineering problems of NFP it is shown that in particular the radiation material sciences have DPF as a very efficient tool for radiation tests of prospect materials and for improvement of their characteristics. In the field of broad-band current applications some results obtained in the fields of radiation material sciences, radiobiology, nuclear medicine, express Neutron Activation Analysis (including a single-shot interrogation of hidden illegal objects), dynamic non-destructive quality control, X-Ray microlithography and micromachining, and micro-radiography are presented. As the examples of the potential future applications it is proposed to use DPF as a powerful high-flux neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration for innovative experiments in nuclear physics, for the goals of radiation treatment of malignant tumors, for neutron tests of materials of the first wall, blankets and NFP device's constructions (with fluences up to 1 dpa per a year term), and ns pulses of fast electrons, neutrons and hard X-Rays for brachytherapy.

  6. In vitro reproduction of incisal/occlusal cupping/cratering.

    PubMed

    Dzakovich, John J; Oslak, Robert R

    2013-06-01

    Occlusal cupping/cratering (depressed dentin surrounded by elevated rims of enamel) has been postulated to be the result of abrasion, bruxism, attrition, acid erosion, stress corrosion, or a combination of these. The primary etiology or the multifactorial sequence of occlusal cupping/cratering remains scientifically unsubstantiated. The purpose of this study was to reproduce occlusal/incisal cupping/cratering in vitro. This study was designed to create cupping/cratering on the occlusal surfaces of extracted human teeth rather than to quantify the amount of lost tooth structure caused by abrasion. One name-brand toothbrush was tested with 2 different dentifrices (of different abrasive potentials [low and high]) and water only (nonabrasive) on extracted human teeth. Six specimens of 4 teeth each (24 teeth) were subjected to horizontal brushing in a 1:1 toothpaste/water slurry and water only. The control group, brushed with water only, demonstrated no visible loss of tooth structure. Each of the specimens brushed with toothpaste, regardless of the degree of abrasivity, demonstrated visible wear of the dentin, resulting in occlusal/incisal cupping/cratering. Pronounced cupping/cratering was caused by horizontal brushing with commercial toothpastes. Brushing in water demonstrated no visual loss of occlusal tooth structure. (J Prosthet Dent 2013;109:384-391). Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  7. Gate tunneling current and quantum capacitance in metal-oxide-semiconductor devices with graphene gate electrodes

    NASA Astrophysics Data System (ADS)

    An, Yanbin; Shekhawat, Aniruddh; Behnam, Ashkan; Pop, Eric; Ural, Ant

    2016-11-01

    Metal-oxide-semiconductor (MOS) devices with graphene as the metal gate electrode, silicon dioxide with thicknesses ranging from 5 to 20 nm as the dielectric, and p-type silicon as the semiconductor are fabricated and characterized. It is found that Fowler-Nordheim (F-N) tunneling dominates the gate tunneling current in these devices for oxide thicknesses of 10 nm and larger, whereas for devices with 5 nm oxide, direct tunneling starts to play a role in determining the total gate current. Furthermore, the temperature dependences of the F-N tunneling current for the 10 nm devices are characterized in the temperature range 77-300 K. The F-N coefficients and the effective tunneling barrier height are extracted as a function of temperature. It is found that the effective barrier height decreases with increasing temperature, which is in agreement with the results previously reported for conventional MOS devices with polysilicon or metal gate electrodes. In addition, high frequency capacitance-voltage measurements of these MOS devices are performed, which depict a local capacitance minimum under accumulation for thin oxides. By analyzing the data using numerical calculations based on the modified density of states of graphene in the presence of charged impurities, it is shown that this local minimum is due to the contribution of the quantum capacitance of graphene. Finally, the workfunction of the graphene gate electrode is extracted by determining the flat-band voltage as a function of oxide thickness. These results show that graphene is a promising candidate as the gate electrode in metal-oxide-semiconductor devices.

  8. Endovascular Treatment of Veno-Occlusive Behcet's Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tekbas, Guven, E-mail: drgtekbas@gmail.com; Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Gur, Serkan, E-mail: mserkangur@yahoo.com

    Purpose: To retrospectively evaluate the outcome of endovascular treatments for patients with chronic veno-occlusive disease in different vascular beds secondary to Behcet's disease (BD). There are few case reports on the subject, and this is the largest study to date. Materials and Methods: From January 2001 through October 2009, chronic venous occlusions were treated in 10 patients (all male [age range 18-76 years]) with BD using percutaneous transluminal angioplasty and/or stent placement. All patients were symptomatic and had chronic iliofemoral deep venous thrombosis (DVT; n = 5), central venous occlusion (n = 3), or Budd-Chiari syndrome (BCS; n = 2).more » All patients met criteria of the International Study Group on Behcet's Disease. Results: Two of five patients with DVT had unsuccessful recanalization attempts. Three patients had successful recanalization with stent placement. All three veins were occluded within 1 month with unsuccessful reinterventions. Three patients with chronic central venous occlusion had successful recanalization with percutaneous transluminal angioplasty (n = 1) and stent placement (n = 2). Two patients had reocclusion with successful reintervention. Two BCS patients had successful treatment with stent placements. Overall technical success was 69%, and no procedural complications were encountered. None of the patients with chronic DVT had patent veins; however, all patients with central venous occlusion or BCS had patent veins on color Doppler ultrasonography at follow-up ranging from 3 to 48 months after intervention. Conclusion: Endovenous treatment for chronic iliofemoral DVT due to BD had a poor outcome. However, long-term outcome after endovenous treatment for upper-extremity central venous occlusion and BCS syndrome was good.« less

  9. Compliance with occlusion therapy for childhood amblyopia.

    PubMed

    Wallace, Michael P; Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2013-09-17

    Explore compliance with occlusion treatment of amblyopia in the Monitored and Randomized Occlusion Treatment of Amblyopia Studies (MOTAS and ROTAS), using objective monitoring. Both studies had a three-phase protocol: initial assessment, refractive adaptation, and occlusion. In the occlusion phase, participants were instructed to dose for 6 hours/day (MOTAS) or randomized to 6 or 12 hour/day (ROTAS). Dose was monitored continuously using an occlusion dose monitor (ODM). One hundred and fifty-two patients (71 male, 81 female; 122 Caucasian, 30 non-Caucasian) of mean ± SD age 68 ± 18 months participated. Amblyopia was defined as an interocular acuity difference of at least 0.1 logMAR and was associated with anisometropia in 50, strabismus in 44, and both (mixed) in 58. Median duration of occlusion was 99 days (interquartile range 72 days). Mean compliance was 44%, mean proportion of days with no patch worn was 42%. Compliance was lower (39%) on weekends compared with weekdays (46%, P = 0.04), as was the likelihood of dosing at all (52% vs. 60%, P = 0.028). Compliance was lower when attendance was less frequent (P < 0.001) and with prolonged treatment duration (P < 0.001). Age, sex, amblyopia type, and severity were not associated with compliance. Mixture modeling suggested three subpopulations of patch day doses: less than 30 minutes; doses that achieve 30% to 80% compliance; and doses that achieve around 100% compliance. This study shows that compliance with patching treatment averages less than 50% and is influenced by several factors. A greater understanding of these influences should improve treatment outcome. (ClinicalTrials.gov number, NCT00274664).

  10. Real-Time MRI-Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model

    PubMed Central

    Raval, Amish N.; Karmarkar, Parag V.; Guttman, Michael A.; Ozturk, Cengizhan; Sampath, Smita; DeSilva, Ranil; Aviles, Ronnier J.; Xu, Minnan; Wright, Victor J.; Schenke, William H.; Kocaturk, Ozgur; Dick, Alexander J.; Raman, Venkatesh K.; Atalar, Ergin; McVeigh, Elliot R.; Lederman, Robert J.

    2006-01-01

    Background Endovascular recanalization (guidewire traversal) of peripheral artery chronic total occlusion (CTO) can be challenging. X-Ray angiography resolves CTO poorly. Virtually “blind” device advancement during X-ray-guided interventions can lead to procedure failure, perforation and hemorrhage. Alternatively, magnetic resonance imaging (MRI) may delineate the artery within the occluded segment to enhance procedural safety and success. We hypothesized that real-time MRI (rtMRI) guided CTO recanalization can be accomplished in an animal model. Methods and Results Carotid artery CTO was created by balloon injury in 19 lipid overfed swine. After 6–8 weeks, two underwent direct necropsy analysis for histology, three underwent primary X-ray-guided CTO recanalization attempts, and the remaining 14 underwent rtMRI-guided recanalization attempts in a 1.5T interventional MRI system. rtMRI intervention used custom CTO catheters and guidewires that incorporated MRI receiver antennae to enhance device visibility. The mean length of the occluded segments was 13.3 ± 1.6cm. rtMRI-guided CTO recanalization was successful in 11/14 swine and only 1/3 swine using X-ray alone. After unsuccessful rtMRI (n = 3), X-ray-guided attempts also were all unsuccessful. Conclusions Recanalization of long CTO is feasible entirely using rtMRI guidance. Low profile clinical-grade devices will be required to translate this experience to humans. Endovascular recanalization of chronic total arterial occlusion (CTO) is challenging under conventional X-ray guidance because devices are advanced almost blindly. MRI can image CTO borders and luminal contents, and could potentially guide these procedures. We test the feasibility of real-time MRI guided wire traversal in a swine model of peripheral artery CTO using custom active MRI catheters. PMID:16490819

  11. Melorheostosis with occlusion of dorsalis pedis artery.

    PubMed

    Ishibe, Motomi; Inoue, Masayuki; Saitou, Katsutoshi

    2002-02-01

    Melorheostosis is an unusual sclerotic dysplasia of bone. The case of a 51-year-old female patient with melorheostosis and occlusion of the dorsalis pedis artery is described. Although numerous vascular anomalies have been noted in patients with melorheostosis, occlusion of the dorsalis pedis artery has not been reported previously.

  12. Amalric sign: An augur of ophthalmic artery occlusion

    PubMed Central

    Hande, Prathibha; Sinha, Babi; Nayak, Shivani; Srinivasan, Srilakshmi; Shetty, Jyothi

    2017-01-01

    A 75-year-old man presented to us with sudden onset of profound vision loss in his right eye and was identified as suffering from an ophthalmic artery occlusion. Apart from the retinal whitening and box-carring of the retinal arteries, there were characteristic triangular patches of retinal whitening in the midperipheral temporal fundus indicating a previous lateral posterior choroidal artery occlusion. The patient was a chronic smoker and had dyslipidemia. The carotid Doppler study showed complete occlusion of the internal carotid artery. The presence of these triangular patches of retinal whitening or amalric sign can therefore herald a more proximal vessel occlusion. Hence such patients require evaluation on an emergency basis. The characteristic features of the patches on fluorescein angiography and indocyanine green angiography are discussed here. PMID:29044080

  13. Amalric sign: An augur of ophthalmic artery occlusion.

    PubMed

    Hande, Prathibha; Sinha, Babi; Nayak, Shivani; Srinivasan, Srilakshmi; Shetty, Jyothi

    2017-10-01

    A 75-year-old man presented to us with sudden onset of profound vision loss in his right eye and was identified as suffering from an ophthalmic artery occlusion. Apart from the retinal whitening and box-carring of the retinal arteries, there were characteristic triangular patches of retinal whitening in the midperipheral temporal fundus indicating a previous lateral posterior choroidal artery occlusion. The patient was a chronic smoker and had dyslipidemia. The carotid Doppler study showed complete occlusion of the internal carotid artery. The presence of these triangular patches of retinal whitening or amalric sign can therefore herald a more proximal vessel occlusion. Hence such patients require evaluation on an emergency basis. The characteristic features of the patches on fluorescein angiography and indocyanine green angiography are discussed here.

  14. Intravitreal triamcinolone acetonide injections in the treatment of retinal vein occlusions.

    PubMed

    Roth, Daniel B; Cukras, Catherine; Radhakrishnan, Ravi; Feuer, William J; Yarian, David L; Green, Stuart N; Wheatley, Harold M; Prenner, Jonathan

    2008-01-01

    To report the visual acuity response after intravitreal triamcinolone injection in patients with macular edema due to retinal vein occlusions. Retrospective nonrandomized interventional series of 172 consecutive patients with macular edema due to retinal vein occlusions who were treated with intravitreal triamcinolone acetonide injection. Patients underwent Snellen visual acuity testing and ophthalmoscopic examination at baseline and 1, 3, 6, and 12 months after intravitreal triamcinolone acetonide injection. All subtypes of retinal vein occlusions showed significant improvements in mean visual acuity 1 month after injection. This improvement in visual acuity was maintained over the 12-month period for all but the central retinal vein occlusion group. Seventy-one (41.3%) of the 172 patients received more than one intravitreal triamcinolone injection for unresolved or recurrent macular edema. This study demonstrates a benefit associated with intravitreal triamcinolone acetonide injection for retinal vein occlusions that was maintained by patients with branch retinal vein occlusions and hemiretinal vein occlusions over a 12-month period. Visual acuity improvement was not maintained in patients with central retinal vein occlusions with this course of treatment.

  15. Graphene-Nanodiamond Heterostructures and their application to High Current Devices

    PubMed Central

    Zhao, Fang; Vrajitoarea, Andrei; Jiang, Qi; Han, Xiaoyu; Chaudhary, Aysha; Welch, Joseph O.; Jackman, Richard B.

    2015-01-01

    Graphene on hydrogen terminated monolayer nanodiamond heterostructures provides a new way to improve carrier transport characteristics of the graphene, offering up to 60% improvement when compared with similar graphene on SiO2/Si substrates. These heterostructures offers excellent current-carrying abilities whilst offering the prospect of a fast, low cost and easy methodology for device applications. The use of ND monolayers is also a compatible technology for the support of large area graphene films. The nature of the C-H bonds between graphene and H-terminated NDs strongly influences the electronic character of the heterostructure, creating effective charge redistribution within the system. Field effect transistors (FETs) have been fabricated based on this novel herterostructure to demonstrate device characteristics and the potential of this approach. PMID:26350107

  16. Progression of Diabetic Capillary Occlusion: A Model

    PubMed Central

    Gens, John Scott; Glazier, James A.; Burns, Stephen A.; Gast, Thomas J.

    2016-01-01

    An explanatory computational model is developed of the contiguous areas of retinal capillary loss which play a large role in diabetic maculapathy and diabetic retinal neovascularization. Strictly random leukocyte mediated capillary occlusion cannot explain the occurrence of large contiguous areas of retinal ischemia. Therefore occlusion of an individual capillary must increase the probability of occlusion of surrounding capillaries. A retinal perifoveal vascular sector as well as a peripheral retinal capillary network and a deleted hexagonal capillary network are modelled using Compucell3D. The perifoveal modelling produces a pattern of spreading capillary loss with associated macular edema. In the peripheral network, spreading ischemia results from the progressive loss of the ladder capillaries which connect peripheral arterioles and venules. System blood flow was elevated in the macular model before a later reduction in flow in cases with progression of capillary occlusions. Simulations differing only in initial vascular network structures but with identical dynamics for oxygen, growth factors and vascular occlusions, replicate key clinical observations of ischemia and macular edema in the posterior pole and ischemia in the retinal periphery. The simulation results also seem consistent with quantitative data on macular blood flow and qualitative data on venous oxygenation. One computational model applied to distinct capillary networks in different retinal regions yielded results comparable to clinical observations in those regions. PMID:27300722

  17. Single-Center Experience Using the 3MAX Reperfusion Catheter for the Treatment of Acute Ischemic Stroke with Distal Arterial Occlusions.

    PubMed

    Premat, Kévin; Bartolini, Bruno; Baronnet-Chauvet, Flore; Shotar, Eimad; Degos, Vincent; Muresan, Paul; Di Maria, Federico; Gabrieli, Joseph; Rosso, Charlotte; Pistocchi, Silvia; Chiras, Jacques; Sourour, Nader; Alamowitch, Sonia; Samson, Yves; Clarençon, Frédéric

    2017-05-15

    Most recent guidelines recommend the use of stent retriever devices in endovascular treatment of acute ischemic stroke with large vessel occlusion (LVO). Recently published data reported convincing results with thromboaspiration devices such as the Penumbra System (Penumbra, Alameda, CA, USA) combined with supple reperfusion catheters by using the ADAPT (A Direct Aspiration First-Pass Thrombectomy) technique. The aim of this study was to report our initial experience with the 3MAX (3.8 F) reperfusion catheter for the recanalization of distal intracranial arteries. From August 2015 to December 2016, 32 consecutive patients (16 females, 50%; mean age = 67.4 ± 18.7 years, range: 22-91) for 38 distal occlusions underwent mechanical thrombectomy (MT) by thromboaspiration using the 3MAX. Median NIHSS score at admission was 14 (IQR: 9-19). Distal occlusions were distributed as follows: M2 (n: 23), M3 (n: 6), P1 (n: 3), P2 (n: 2), P3 (n: 2), A3 segment (n: 1) and superior cerebellar artery (n: 1). In 1/38 (2.6%) target artery, the 3MAX could not be navigated. Of the 37 (59.5%) remaining arteries, 22 were successfully reperfused (TICI 2b/3) after ADAPT with the 3MAX alone. Additional stent retriever thrombectomy allowed a 76.3% final reperfusion rate. Good functional outcome (mRS ≤2) was obtained in 45.5% of patients at 3 months. Three (9.4%) 3MAX-related complications occurred: 2 emboli to new territory (ENT) and one vascular perforation. The 3MAX is well-navigable in distal arteries making it useful as a frontline technique. However, the reperfusion rate with the 3MAX catheter alone seems lower than the ones reported with stent retrievers for such distal occlusions.

  18. Guide Catheter Extension Device Is Effective in Renal Angioplasty for Severely Calcified Lesions

    PubMed Central

    Sugimoto, Takeshi; Nomura, Tetsuya; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Kikai, Masakazu; Keira, Natsuya; Tatsumi, Tetsuya

    2017-01-01

    Patient: Male, 69 Final Diagnosis: Atherosclerotic renal artery stenosis Symptoms: None Medication: — Clinical Procedure: — Specialty: Radiology Objective: Unusual setting of medical care Background: The GuideLiner catheter extension device is a monorail-type “Child” support catheter that facilitates coaxial alignment with the guide catheter and provides an appropriate back-up force. This device has been developed in the field of coronary intervention, and now is becoming widely applied in the field of endovascular treatment. However, there has been no report on the effectiveness of the guide catheter extension device in percutaneous transluminal renal angioplasty (PTRA). Case Report: We encountered a case of atherosclerotic subtotal occlusion at the ostium of the left renal artery. Due to the severely calcified orifice and weaker back-up force provided by a JR4 guide catheter, we could not pass any guide-wires through the target lesion. Therefore, we introduced a guide catheter extension device, the GuideLiner catheter, through the guide catheter and achieved good guidewire maneuverability. We finally deployed 2 balloon-expandable stents and successfully performed all PTRA procedures. Conclusions: The guide catheter extension device can be effective in PTRA for severely calcified subtotal occlusion. PMID:28533503

  19. Retinal vein occlusion

    MedlinePlus

    ... of one eye. Exams and Tests Tests to evaluate for vein occlusion include: Exam of the retina after dilating the pupil An eye test that uses a special dye and camera to look at blood flow in the retina and choroid. Intraocular pressure Pupil ...

  20. A Report on Deliverable Five: Evaluate Current Commercially Available Suction Pump Devices for Use in Prehospital Combat Care

    DTIC Science & Technology

    Develop a consumer-style report for currently available suction pump devices on the market . List parameters such as suction flow rate, pressure...evaluate whether suction devices that are currently on the market meet these requirements.

  1. Role of occlusion in endodontic management: report of two cases.

    PubMed

    Yu, Christine Y

    2004-12-01

    The two clinical cases reported demonstrate that traumatic occlusion can play a role in the initiation and progression of pulp and periradicular inflammation. The symptom of persistent pain did not subside after the commencement of endodontic treatment. Traumatic occlusion was identified in both cases to be the main cause and hence occlusal adjustment was performed. This resulted in the gradual resolution of the symptoms. The findings suggest that occlusal trauma is often overlooked in the diagnosis and management of endodontic diseases.

  2. Current management of peripheral arterial occlusive disease: a review of pharmacologic agents and other interventions.

    PubMed

    Mannava, Krishna; Money, Samuel R

    2007-01-01

    Peripheral arterial occlusive disease (PAOD) of the lower extremities is becoming more prevalent worldwide. Nonsurgical treatment options provide the foundation for management. Lifestyle and risk factor modification should be emphasized in this patient population because of the associated adverse cardiovascular events. This includes implementation of a regular walking and smoking-cessation programs, aggressive control of hyperlipidemia, hypertension and diabetes mellitus, and treatment of hyperhomocysteinemia. Antiplatelet agents such as aspirin (acetylsalicylic acid) or clopidogrel are not specifically indicated for claudication but these drugs should be used in all patients with PAOD to prevent secondary ischemic events. Currently, cilostazol is the only US FDA approved agent that appears effective for the treatment of claudication symptoms. Several agents have been used with success outside of the US and others are still undergoing testing. Definitive recommendations cannot be made on the use of these drugs until further evaluation is completed. Ongoing research with new strategies for angiogenesis and the use of progenitor cells has yielded encouraging results, particularly for patients with critical limb ischemia and limited options. Advances in endovascular technology over the last several years have greatly enhanced the ability to diagnose and treat specific anatomic lesions that previously would have required open surgical correction. The use of percutaneous transluminal angioplasty and stents in the lower extremities has had considerable success when following specific guidelines such as those set forth by the TransAtlantic Inter-Society Consensus Working Group.

  3. Evaluation of the occlusal contact of crowns fabricated with the bite impression method.

    PubMed

    Makino, Sachi; Okada, Daizo; Shin, Chiharu; Ogura, Reiko; Ikeda, Masaomi; Miura, Hiroyuki

    2013-09-30

    In prosthodontic treatment, reconstruction of a proper occlusal contact relationship is very important as well as reconstruction of a proper interproximal relationship and marginal fitness. Unfortunately, occlusal relationships are sometimes lost in the process of occlusal adjustment of crowns. The purpose of this study was to compare the occlusal contacts of single crown fabricated by two different types of impression techniques. Nine subjects, whose molars required treatment with crown restoration, were enrolled in this study. Full cast crowns were fabricated using two types of impression techniques: the conventional impression method (CIM) and the bite impression method (BIM). The occlusal contacts of crowns were precisely evaluated at the following stages: after occlusal adjustment on the articulator (Step 0), before occlusal adjustment in the mouth (Step 1), after occlusal adjustment at the intercuspal position (Step 2), and after occlusal adjustment during lateral and protrusive excursions (Step 3). The number of occlusal contacts of the crowns on the functional cusps fabricated with BIM was significantly greater than that with CIM after occlusal adjustment. For this reason, the crowns fabricated with BIM might have a more functionally desirable occlusal surface compared to the crowns fabricated with CIM.

  4. [Comparison of 2 lacrimal punctal occlusion methods].

    PubMed

    Shalaby, O; Rivas, L; Rivas, A I; Oroza, M A; Murube, J

    2001-09-01

    To study and compare two methods for canalicular occlusion: Cautery and Punctal Patch. The study included fourty patients divided in two groups of 20 patients. The end point was 4 occluded puncti. The first group underwent deep cauterization resulting in occlusion of the full vertical aspect of the canaliculus. The second group underwent punctal patch technique for canalicular occlusion. Differential parameters were the following: time of intervention, ease of use, risks and precision. In the post operatory, discomfort, subjective and objective improvement in ocular surface as well as long term result of each technique was analysed. Time of intervention was longer for punctal patch compared to cautery. Both methods exhibited similar ease of use and improvement in ocular surface. Precision was high in punctal patch technique showing complete and final occlusion and no punctum needed reopening, while cautery technique presented 20% rate of reopening intervention. Postoperatory discomfort and irritation were remarkably evident with punctal technique, while minimal in cautery technique. Survival analysis after one year follow up, showed a higher rate of advantages for punctal patch technique over cautery technique.

  5. Anterior choroidal artery patency and clinical follow-up after coverage with the pipeline embolization device.

    PubMed

    Raz, E; Shapiro, M; Becske, T; Zumofen, D W; Tanweer, O; Potts, M B; Riina, H A; Nelson, P K

    2015-05-01

    Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment. We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed. Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found. After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior

  6. Game theory-based mode cooperative selection mechanism for device-to-device visible light communication

    NASA Astrophysics Data System (ADS)

    Liu, Yuxin; Huang, Zhitong; Li, Wei; Ji, Yuefeng

    2016-03-01

    Various patterns of device-to-device (D2D) communication, from Bluetooth to Wi-Fi Direct, are emerging due to the increasing requirements of information sharing between mobile terminals. This paper presents an innovative pattern named device-to-device visible light communication (D2D-VLC) to alleviate the growing traffic problem. However, the occlusion problem is a difficulty in D2D-VLC. This paper proposes a game theory-based solution in which the best-response dynamics and best-response strategies are used to realize a mode-cooperative selection mechanism. This mechanism uses system capacity as the utility function to optimize system performance and selects the optimal communication mode for each active user from three candidate modes. Moreover, the simulation and experimental results show that the mechanism can attain a significant improvement in terms of effectiveness and energy saving compared with the cases where the users communicate via only the fixed transceivers (light-emitting diode and photo diode) or via only D2D.

  7. Towards an Active Hearing Protection Device for Musicians =

    NASA Astrophysics Data System (ADS)

    Bernier, Antoine

    Professional musicians are oftentimes exposed to high levels of sound. Prolonged or severe exposure to high sound levels could lead to permanent hearing loss and compromise their career. The logical solution would be to wear hearing protection devices (HPDs) when appropriate. However, perceptual discomfort associated with wearing HPD can discourage their use by musicians. The perceptual discomfort is caused by two detrimental effects: the occlusion effect and the isolation effect. The occlusion effect is often reported as an augmented, unnatural and annoying perception of one's own voice or instrument mechanically coupled to the head when wearing HPDs. The isolation effect is the unnatural sensation of being isolated from a given sound environment and can be caused by wearing HPDs that do not compensate for psychoacoustical factors and therefore alter the wearer's auditory perception. Both effects are highly unfavorable to the musicians' auditory perception and compromise their capacity to perform to the best of their abilities for their audience. They are among the reasons most often reported by musicians to decide not to wear HPDs. This master's project presents the concept and first prototype of an active HPD for musicians that aims at solving the detrimental effects while protecting the musician's hearing. A solution for the occlusion effect is presented in the form of an earplug complemented with in-ear active noise control. Practical design issues and required trade-off are analyzed through a literature review and the implementation and characterization of an active occlusion effect reduction system, allowing reduction of the occlusion effect between 8.5 and 12 dB at 250 Hz. A solution for the isolation effect is presented in the form of an earplug complemented with digital signal processing capabilities. Factors that may cause the isolation effect are identified through a literature review and corresponding algorithms that aim at re-establishing the

  8. Collateral Circulation in Chronic Total Occlusions - an interventional perspective.

    PubMed

    Choo, Gim-Hooi

    2015-09-09

    Human coronary collaterals are inter-coronary communications that are believed to be present from birth. In the presence of chronic total occlusions, recruitment of flow via these collateral anastomoses to the arterial segment distal to occlusion provide an alternative source of blood flow to the myocardial segment at risk. This mitigates the ischemic injury. Clinical outcome of coronary occlusion ie. severity of myocardial infarction/ischemia, impairment of cardiac function and possibly survival depends not only on the acuity of the occlusion, extent of jeopardized myocardium, duration of ischemia but also to the adequacy of collateral circulation. Adequacy of collateral circulation can be assessed by various methods. These coronary collateral channels have been used successfully as a retrograde access route for percutaneous recanalization of chronic total occlusions. Factors that promote angiogenesis and further collateral remodeling ie. arteriogenesis have been identified. Promotion of collateral growth as a therapeutic target in patients with no suitable revascularization option is an exciting proposal.

  9. Acute pancreatitis during sickle cell vaso-occlusive painful crisis.

    PubMed

    Ahmed, Shahid; Siddiqui, Anita K; Siddiqui, Rina K; Kimpo, Miriam; Russo, Linda; Mattana, Joseph

    2003-07-01

    Sickle cell disease is characterized by chronic hemolytic anemia and vaso-occlusive painful crisis. The vascular occlusion in sickle cell disease is a complex process and accounts for the majority of the clinical manifestations of the disease. Abdominal pain is an important component of vaso-occlusive painful crisis and may mimic diseases such as acute appendicitis and cholecystitis. Acute pancreatitis is rarely included as a cause of abdominal pain in patients with sickle cell disease. When it occurs it may result form biliary obstruction, but in other instances it might be a consequence of microvessel occlusion causing ischemia. In this series we describe four cases of acute pancreatitis in patients with sickle cell disease apparently due to microvascular occlusion and ischemic injury to the pancreas. All patients responded to conservative management. Acute pancreatitis should be considered in the differential diagnosis of abdominal pain in patients with sickle cell disease. Copyright 2003 Wiley-Liss, Inc.

  10. First Pass Effect: A New Measure for Stroke Thrombectomy Devices.

    PubMed

    Zaidat, Osama O; Castonguay, Alicia C; Linfante, Italo; Gupta, Rishi; Martin, Coleman O; Holloway, William E; Mueller-Kronast, Nils; English, Joey D; Dabus, Guilherme; Malisch, Tim W; Marden, Franklin A; Bozorgchami, Hormozd; Xavier, Andrew; Rai, Ansaar T; Froehler, Michael T; Badruddin, Aamir; Nguyen, Thanh N; Taqi, M Asif; Abraham, Michael G; Yoo, Albert J; Janardhan, Vallabh; Shaltoni, Hashem; Novakovic, Roberta; Abou-Chebl, Alex; Chen, Peng R; Britz, Gavin W; Sun, Chung-Huan J; Bansal, Vibhav; Kaushal, Ritesh; Nanda, Ashish; Nogueira, Raul G

    2018-03-01

    In acute ischemic stroke, fast and complete recanalization of the occluded vessel is associated with improved outcomes. We describe a novel measure for newer generation devices: the first pass effect (FPE). FPE is defined as achieving a complete recanalization with a single thrombectomy device pass. The North American Solitaire Acute Stroke Registry database was used to identify a FPE subgroup. Their baseline features and clinical outcomes were compared with non-FPE patients. Clinical outcome measures included 90-days modified Rankin Scale score, National Institutes of Health Stroke Scale score, mortality, and symptomatic intracranial hemorrhage. Multivariate analyses were performed to determine whether FPE independently resulted in improved outcomes and to identify predictors of FPE. A total of 354 acute ischemic stroke patients underwent thrombectomy in the North American Solitaire Acute Stroke registry. FPE was achieved in 89 out of 354 (25.1%). More middle cerebral artery occlusions (64% versus 52.5%) and fewer internal carotid artery occlusions (10.1% versus 27.7%) were present in the FPE group. Balloon guide catheters were used more frequently with FPE (64.0% versus 34.7%). Median time to revascularization was significantly faster in the FPE group (median 34 versus 60 minutes; P =0.0003). FPE was an independent predictor of good clinical outcome (modified Rankin Scale score ≤2 was seen in 61.3% in FPE versus 35.3% in non-FPE cohort; P =0.013; odds ratio, 1.7; 95% confidence interval, 1.1-2.7). The independent predictors of achieving FPE were use of balloon guide catheters and non-internal carotid artery terminus occlusion. The achievement of complete revascularization from a single Solitaire thrombectomy device pass (FPE) is associated with significantly higher rates of good clinical outcome. The FPE is more frequently associated with the use of balloon guide catheters and less likely to be achieved with internal carotid artery terminus occlusion. © 2018

  11. Occlusion of Arteriovenous Fistulas of In-Situ Saphenous Vein Bypass Grafts Using the Amplatzer Vascular Plug 4: Initial Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libicher, Martin, E-mail: martin.libicher@uk-koeln.de; Reichert, V.; Schwabe, H.

    2011-06-15

    We examined the safety and efficacy of vessel occlusion of the Amplatzer Vascular Plug 4 (AVP-4) in patients with arteriovenous fistulas after in-situ saphenous vein bypass grafts. We treated 18 fistulas of seven patients (four women, mean {+-} standard deviation age 76 {+-} 7 years, range 63-88 years). All fistulas were detected within 14 days after surgery. Initial diagnosis and follow-up was established by sonography. We measured the diameter of the feeding vessel and the time of vessel occlusion after plug deployment. Additionally, we recorded procedure time and the dose area product. Additional interventional procedures were necessary in three patients.more » We successfully used 19 AVP-4 for occlusion of all fistulas without thromboembolic complications. There was no need for recapturing the device, and we did not observe dislocation. Mean occlusion time was 9.6 min (range 5-22 min). Mean diameter of the feeding vessels was 3.5 mm (range 2.6-5.1 mm). Plug sizes ranged from 4-8 mm (mean 5.5 mm) resulting in an oversizing of 33-88%. Mean procedure time for patients with and without additional intervention was 91 {+-} 38 min and 35 {+-} 18 min, respectively. Mean dose area product was 11,790 cGy/cm{sup 2} (range 1,850-23,500 cGy/cm{sup 2}). Permanent occlusion of the fistulas was confirmed by ultrasound after a mean follow-up of 4 months (1-6 months). Occlusion of arteriovenous fistulas with an AVP-4 seems to be effective and safe in patients with in-situ saphenous vein bypass grafts. The AVP-4 is well suited for this purpose because of the appropriate diameter of the feeding vessels.« less

  12. Computational evaluation of aortic occlusion and the proposal of a novel, improved occluder: Constrained endo-aortic balloon occlusion.

    PubMed

    de Vaal, M H; Gee, M W; Stock, U A; Wall, W A

    2016-12-01

    Because aortic occlusion is arguably one of the most dangerous aortic manipulation maneuvers during cardiac surgery in terms of perioperative ischemic neurological injury, the purpose of this investigation is to assess the structural mechanical impact resulting from the use of existing and newly proposed occluders. Existing (clinically used) occluders considered include different cross-clamps (CCs) and endo-aortic balloon occlusion (EABO). A novel occluder is also introduced, namely, constrained EABO (CEABO), which consists of applying a constrainer externally around the aorta when performing EABO. Computational solid mechanics are employed to investigate each occluder according to a comprehensive list of functional requirements. The potential of a state of occlusion is also considered for the first time. Three different constrainer designs are evaluated for CEABO. Although the CCs were responsible for the highest strains, largest deformation, and most inefficient increase of the occlusion potential, it remains the most stable, simplest, and cheapest occluder. The different CC hinge geometries resulted in poorer performance of CC used for minimally invasive procedures than conventional ones. CEABO with a profiled constrainer successfully addresses the EABO shortcomings of safety, stability, and positioning accuracy, while maintaining its complexities of operation (disadvantage) and yielding additional functionalities (advantage). Moreover, CEABO is able to achieve the previously unattainable potential to provide a clinically determinable state of occlusion. CEABO offers an attractive alternative to the shortcomings of existing occluders, with its design rooted in achieving the highest patient safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Influence of occlusal contact area on cusp defection and stress distribution.

    PubMed

    Costa, Anna Karina Figueiredo; Xavier, Thaty Aparecida; Paes-Junior, Tarcisio José Arruda; Andreatta-Filho, Oswaldo Daniel; Borges, Alexandre Luiz Souto

    2014-11-01

    The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental

  14. Flow diverter device for the treatment of small middle cerebral artery aneurysms.

    PubMed

    Briganti, Francesco; Delehaye, Luigi; Leone, Giuseppe; Sicignano, Carmine; Buono, Giuseppe; Marseglia, Mariano; Caranci, Ferdinando; Tortora, Fabio; Maiuri, Francesco

    2016-03-01

    Experience with the endovascular treatment of middle cerebral artery (MCA) aneurysms by flow diverter devices (FDD) is still limited. This study examines the results and complications of FDD for small aneurysms at this location. From February 2010 to December 2013, 14 patients (10 women; mean age 59 years) with 15 small MCA aneurysms were treated with FDD. All procedures were performed with the Pipeline embolization device (PED). Complete occlusion was obtained in 12/15 aneurysms (80%) and partial occlusion in 3 (20%). Among 13 aneurysms with a side branch, this was patent at the angiographic control in 4 cases, showed decreased filling in 6, and was occluded in 3 (with neurological deficits in 2). All PEDs were patent at follow-up. Post-procedural ischemic complications occurred in 4 (27%) procedures with permanent neurological deficit (modified Rankin score 2) in 3 (21%). No early or delayed aneurysm rupture, no subarachnoid or intraparenchymal hemorrhage and no deaths occurred. Endovascular treatment with FDD is a relatively safe treatment for small MCA aneurysms resulting in a high occlusion rate. The findings of this study suggest that complete occlusion after endovascular treatment with FDD can be delayed (>6 months). Ischemic complications may occur as early or delayed, particularly at clopidogrel interruption. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. Venous sinus occlusive disease: MR findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuh, W.T.C.; Simonson, T.M.; Tali, E.T.

    1994-02-01

    To study MR patterns of venous sinus occlusive disease and to relate them to the underlying pathophysiology by comparing the appearance and pathophysiologic features of venous sinus occlusive disease with those of arterial ischemic disease. The clinical data and MR examinations of 26 patients with venous sinus occlusive disease were retrospectively reviewed with special attention to mass effect, hemorrhage, and T2-weighted image abnormalities as well as to abnormal parenchymal, venous, or arterial enhancement after intravenous gadopentetate dimeglumine administration. Follow-up studies when available were evaluated for atrophy, infraction, chronic mass effect, and hemorrhage. Mass effect was present in 25 of 26more » patients. Eleven of the 26 had mass effect without abnormal signal on T2-weighted images. Fifteen patients had abnormal signal on T2-weighted images, but this was much less extensive than the degree of brain swelling in all cases. No patient showed abnormal parenchymal or arterial enhancement. Abnormal venous enhancement was seen in 10 of 13 patients who had contrast-enhanced studies. Intraparenchymal hemorrhage was seen in nine patients with high signal on T2-weighted images predominantly peripheral to the hematoma in eight. Three overall MR patterns were observed in acute sinus thrombosis: (1) mass effect without associated abnormal signal on T2-weighted images, (2) mass effect with associated abnormal signal on T2-weighted images and/or ventricular dilatation that may be reversible, and (3) intraparenchymal hematoma with surrounding edema. MR findings of venus sinus occlusive disease are different from those of arterial ischemia and may reflect different underlying pathophysiology. In venous sinus occlusive disease, the breakdown of the blood-brain barrier (vasogenic edema and abnormal parenchymal enhancement) does not always occur, and brain swelling can persist up to 2 years with or without abnormal signal on T2-weighted images. 34 refs., 5 figs.« less

  16. Device for plasma confinement and heating by high currents and nonclassical plasma transport properties

    DOEpatents

    Coppi, B.; Montgomery, D.B.

    1973-12-11

    A toroidal plasma containment device having means for inducing high total plasma currents and current densities and at the same time emhanced plasma heating, strong magnetic confinement, high energy density containment, magnetic modulation, microwaveinduced heating, and diagnostic accessibility is described. (Official Gazette)

  17. Medina® Embolization Device for the Treatment of Intracranial Aneurysms: Safety and Angiographic Effectiveness at 6 Months.

    PubMed

    Sourour, Nader-Antoine; Vande Perre, Saskia; Maria, Federico Di; Papagiannaki, Chrysanthi; Gabrieli, Joseph; Pistocchi, Silvia; Bartolini, Bruno; Degos, Vincent; Carpentier, Alexandre; Chiras, Jacques; Clarençon, Frédéric

    2018-02-01

    The Medina Embolization Device (MED) is a new concept device that combines the design of a detachable coil and the one of an intrasaccular flow disruption device. To evaluate the feasibility, safety, and 6- to 9-mo effectiveness of this new device for the treatment of intracranial wide-necked aneurysms. Twelve patients (10 females, mean age = 56 yr) with 13 wide-necked intracranial aneurysms (3 ruptured; 10 unruptured) were treated by means of the MED from January 2015 to October 2015. In 15% of the cases, MEDs were used in a standalone fashion; in 85% of the cases, additional regular coils were used. Adjunctive compliant balloon was used in 4 of 13 cases (31%). Procedure-related complications were systematically recorded; discharge and 6- to 9-mo follow-up modified Rankin Scale was assessed. Angiographic follow-up was performed with a mean delay of 5.5 ± 1.7 mo. Occlusion rate was evaluated in postprocedure and at midterm follow-up using the Roy-Raymond scale. The deployment of the MED was feasible in all cases. No perforation was recorded. One case of thromboembolic complication was observed in a ruptured anterior communicating artery aneurysm, without any clinical consequence at follow-up. Grade A occlusion rate was 61.5% in postprocedure and 83% at 6-mo follow-up. Two cases (17%) of recanalization were documented angiographically. The MED is a new generation device combining the design of a detachable coil and an intrasaccular flow disruption device. According to our early experience, this device is safe and provides a satisfactory occlusion rate at angiographic follow-up of 6 mo. Copyright © 2017 by the Congress of Neurological Surgeons

  18. Automated vision occlusion-timing instrument for perception-action research.

    PubMed

    Brenton, John; Müller, Sean; Rhodes, Robbie; Finch, Brad

    2018-02-01

    Vision occlusion spectacles are a highly valuable instrument for visual-perception-action research in a variety of disciplines. In sports, occlusion spectacles have enabled invaluable knowledge to be obtained about the superior capability of experts to use visual information to guide actions within in-situ settings. Triggering the spectacles to occlude a performer's vision at a precise time in an opponent's action or object flight has been problematic, due to experimenter error in using a manual buttonpress approach. This article describes a new laser curtain wireless trigger for vision occlusion spectacles that is portable and fast in terms of its transmission time. The laser curtain can be positioned in a variety of orientations to accept a motion trigger, such as a cricket bowler's arm that distorts the lasers, which then activates a wireless signal for the occlusion spectacles to change from transparent to opaque, which occurs in only 8 ms. Results are reported from calculations done in an electronics laboratory, as well as from tests in a performance laboratory with a cricket bowler and a baseball pitcher, which verified this short time delay before vision occlusion. In addition, our results show that occlusion consistently occurred when it was intended-that is, near ball release and during mid-ball-flight. Only 8% of the collected data trials were unusable. The laser curtain improves upon the limitations of existing vision occlusion spectacle triggers, indicating that it is a valuable instrument for perception-action research in a variety of disciplines.

  19. Virtual occlusal definition for orthognathic surgery.

    PubMed

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Band to Band Tunneling (BBT) Induced Leakage Current Enhancement in Irradiated Fully Depleted SOI Devices

    NASA Technical Reports Server (NTRS)

    Adell, Phillipe C.; Barnaby, H. J.; Schrimpf, R. D.; Vermeire, B.

    2007-01-01

    We propose a model, validated with simulations, describing how band-to-band tunneling (BBT) affects the leakage current degradation in some irradiated fully-depleted SOI devices. The dependence of drain current on gate voltage, including the apparent transition to a high current regime is explained.

  1. On the relevance of "ideal" occlusion concepts for incisor inclination target definition.

    PubMed

    Knösel, Michael; Jung, Klaus

    2011-11-01

    The concept of "ideal" occlusion in harmony with craniofacial structures is often proposed as an ultimate goal of orthodontic treatment. The aim of this study was to assess the impact of slight variations in posterior occlusion and the history of straight-wire orthodontic treatment on the predictability of incisor inclination and third-order angles. Axial incisor inclinations, third-order angles, and craniofacial relationships were assessed on lateral headfilms and corresponding dental casts of 75 healthy white subjects, 16 to 26 years old, selected by the general inclusion criterion of a good interincisal relationship. Four groups were formed: group A (n = 17), Angle Class I occlusion subjects with no orthodontic treatment; group B (n = 20), Angle Class I occlusion subjects treated with standardized straight-wire orthodontics; group C (n = 20), up to a half-cusp distal occlusion after straight-wire treatment; and group D (n = 18), up to a half-cusp distal occlusion and no orthodontic treatment. Regression analysis was used to insert predictor angles into selected regression equations of the subjects with "ideal" occlusion, and the absolute differences between predicted and observed response angles were determined. Small differences in incisor inclination were found between subjects with "ideal" occlusion and those who slightly deviated from "ideal" with a mild occlusion of the Angle Class II category. Posterior occlusion was not relevant to the validity of the vast majority of predictor-response pairs. Straight-wire treatment produced incisor inclination that was slightly protruded compared with subjects who had good natural occlusion. The "ideal" posterior occlusion concepts as a general orthodontic treatment goal should be reconsidered. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  2. Endothelial effects of hemostatic devices for continuous cardioplegia or minimally invasive operations.

    PubMed

    Perrault, L P; Menasché, P; Wassef, M; Bidouard, J P; Janiak, P; Villeneuve, N; Jacquemin, C; Bloch, G; Vilaine, J P; Vanhoutte, P M

    1996-10-01

    Improvements in myocardial protection may include the continuous delivery of normothermic blood cardioplegia. Technical aids are required for optimal visualization of the operative field during the performance of coronary anastomoses if cardioplegia is to be given continuously or during minimally invasive operations. However, the effects of the different hemostatic devices on coronary endothelial function are unknown. We compared the effects on endothelial function of two commonly used hemostatic techniques, coronary clamping and gas jet insufflation, with those of a technique using extravascular balloon occlusion to mimic systolic luminal closure by the surrounding myocardium. The three techniques were applied for 15 minutes on porcine epicardial coronary arteries from explanted hearts. For coronary clamping, standard bulldog clamps were used. Gas jet insufflation was applied by blowing oxygen (12 L/min) tangentially at a 45-degree angle 1 cm away from a 3-mm arteriotomy. Extravascular balloon occlusion was achieved with a needle-tipped silicone loop, the midportion of which, once positioned beneath the coronary artery, was inflated to push a myocardial "cushion" against the back of the vessel until its occlusion. Control rings were taken from the same coronary artery. The endothelial function of control and instrumented arterial rings was then studied in organ chambers filled with modified Krebs-Ringer bicarbonate solution. Contractions to potassium chloride and prostaglandin F2 alpha and endothelium-independent relaxation to sin-1, a nitric oxide donor, were unaffected in all groups. Endothelium-dependent relaxation to serotonin was impaired after clamping and preserved after gas jet insufflation and extravascular balloon occlusion. Maximal endothelium-dependent relaxation to serotonin was as follows: for coronary clamping, 63% +/- 6% versus 87% +/- 3% in controls; for gas jet insufflation, 67% +/- 12% versus 88% +/- 7%; and for extraluminal balloon occlusion

  3. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    PubMed

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  4. Coronary Intervention for Persistent Occlusion after Myocardial Infarction

    PubMed Central

    Hochman, Judith S.; Lamas, Gervasio A.; Buller, Christopher E.; Dzavik, Vladimir; Reynolds, Harmony R.; Abramsky, Staci J.; Forman, Sandra; Ruzyllo, Witold; Maggioni, Aldo P.; White, Harvey; Sadowski, Zygmunt; Carvalho, Antonio C.; Rankin, Jamie M.; Renkin, Jean P.; Steg, P. Gabriel; Mascette, Alice M.; Sopko, George; Pfisterer, Matthias E.; Leor, Jonathan; Fridrich, Viliam; Mark, Daniel B.; Knatterud, Genell L.

    2007-01-01

    BACKGROUND It is unclear whether stable, high-risk patients with persistent total occlusion of the infarct-related coronary artery identified after the currently accepted period for myocardial salvage has passed should undergo percutaneous coronary intervention (PCI) in addition to receiving optimal medical therapy to reduce the risk of subsequent events. METHODS We conducted a randomized study involving 2166 stable patients who had total occlusion of the infarct-related artery 3 to 28 days after myocardial infarction and who met a high-risk criterion (an ejection fraction of <50% or proximal occlusion). Of these patients, 1082 were assigned to routine PCI and stenting with optimal medical therapy, and 1084 were assigned to optimal medical therapy alone. The primary end point was a composite of death, myocardial reinfarction, or New York Heart Association (NYHA) class IV heart failure. RESULTS The 4-year cumulative primary event rate was 17.2% in the PCI group and 15.6% in the medical therapy group (hazard ratio for death, reinfarction, or heart failure in the PCI group as compared with the medical therapy group, 1.16; 95% confidence interval [CI], 0.92 to 1.45; P = 0.20). Rates of myocardial reinfarction (fatal and nonfatal) were 7.0% and 5.3% in the two groups, respectively (hazard ratio, 1.36; 95% CI, 0.92 to 2.00; P = 0.13). Rates of nonfatal reinfarction were 6.9% and 5.0%, respectively (hazard ratio, 1.44; 95% CI, 0.96 to 2.16; P = 0.08); only six reinfarctions (0.6%) were related to assigned PCI procedures. Rates of NYHA class IV heart failure (4.4% vs. 4.5%) and death (9.1% vs. 9.4%) were similar. There was no interaction between treatment effect and any subgroup variable (age, sex, race or ethnic group, infarct-related artery, ejection fraction, diabetes, Killip class, and the time from myocardial infarction to randomization). CONCLUSIONS PCI did not reduce the occurrence of death, reinfarction, or heart failure, and there was a trend toward excess

  5. Initial experience with the Cardiva Boomerang vascular closure device in diagnostic catheterization.

    PubMed

    Doyle, Brendan J; Godfrey, Michael J; Lennon, Ryan J; Ryan, James L; Bresnahan, John F; Rihal, Charanjit S; Ting, Henry H

    2007-02-01

    The authors studied the safety and efficacy of the Cardiva Boomerang vascular closure device in patients undergoing diagnostic cardiac catheterization. Conventional vascular closure devices (sutures, collagen plugs, or metal clips) have been associated with catastrophic complications including arterial occlusion and foreign body infections; furthermore, they cannot be utilized in patients with peripheral vascular disease or vascular access site in a vessel other than the common femoral artery. The Cardiva Boomerang device facilitates vascular hemostasis without leaving any foreign body behind at the access site, can be used in peripheral vascular disease, and can be used in vessels other than the common femoral artery A total of 96 patients undergoing transfemoral diagnostic cardiac catheterization were included in this study, including 25 (26%) patients with contraindications to conventional closure devices. Femoral angiography was performed prior to deployment of the Cardiva Boomerang closure device. Patients were ambulated at 1 hr after hemostasis was achieved. The device was successfully deployed and hemostasis achieved with the device alone in 95 (99%) patients. The device failed to deploy in 1 (1%) patient and required conversion to standard manual compression. Minor complications were observed in 5 (5%) patients. No patients experienced major complications including femoral hematoma > 4 cm, red blood cell transfusion, retroperitoneal bleed, arteriovenous fistula, pseudoaneurysm, infection, arterial occlusion, or vascular surgery. The Cardiva Boomerang device is safe and effective in patients undergoing diagnostic cardiac catheterization using the transfemoral approach, facilitating early ambulation with low rates of vascular complications. (c) 2006 Wiley-Liss, Inc.

  6. Mechanism of vaso-occlusion in sickle cell anemia

    NASA Astrophysics Data System (ADS)

    Lei, Huan; Karniadakis, George

    2012-11-01

    Vaso-occlusion crisis is one of the key hallmark of sickle cell anemia. While early studies suggested that the crisis is caused by blockage of a single elongated cell, recent experimental investigations indicate that vaso-occlusion is a complex process triggered by adhesive interactions among different cell groups in multiple stages. Based on dissipative particle dynamics, a multi-scale model for the sickle red blood cells (SS-RBCs), accounting for diversity in both shapes and cell rigidities, is developed to investigate the mechanism of vaso-occlusion crisis. Using this model, the adhesive dynamics of single SS-RBC was investigated in arterioles. Simulation results indicate that the different cell groups (deformable SS2 RBCs, rigid SS4 RBCs, leukocytes, etc.) exhibit heterogeneous adhesive behavior due to the different cell morphologies and membrane rigidities. We further simulate the tube flow of SS-RBC suspensions with different cell fractions. The more adhesive SS2 cells interact with the vascular endothelium and further trap rigid SS4 cells, resulting in vaso-occlusion in vessels less than 15 μm . Under inflammation, adherent leukocytes may also trap SS4 cells, resulting in vaso-occlusion in even larger vessels. This work was supported by the NSF grant CBET-0852948 and the NIH grant R01HL094270.

  7. Occlusal tooth wear in Chinese adults with shortened dental arches.

    PubMed

    Zhang, Q; Witter, D J; Bronkhorst, E M; Bartlett, D W; Creugers, N H J

    2014-02-01

    To assess associations between occlusal tooth wear and shortened dental arches (SDA) in Chinese 40 years and older subjects. From a sample of 1462 urban and rural adults, those presenting with SDA (n = 150) were compared with a control group of 65 randomly selected subjects with complete dentitions (CDA). Occlusal wear was assessed using a modified Smith and Knight index - the occlusal tooth wear index (OWTI) - and analysed using multivariate (logistic) regression. There was no significant effect from SDA on severe occlusal wear (OTWI score 3 or 4: OR = 2.016; 95% CI = 0.960-4.231; P = 0.064). Higher age was associated with severe occlusal wear (P values ≤0.007) and with higher mean OTWI scores; urban had less often severe occlusal wear than rural residents (OR = 0.519; P = 0.008). Higher mean OTWI scores were associated with rural residents, except for anterior teeth. Females had lower mean OTWI score for anterior teeth (effect = -0.153; P = 0.030). Premolars in SDA had higher mean OTWI scores compared with those in CDA (effect = +0.213; P = 0.006). In SDA, more posterior occluding pairs (POPs) were associated with lower mean OTWI sores for anterior teeth (effect: -0.158; P = 0.008) and higher scores for molars (effect: +0.249, P = 0.003). Subjects with SDA or CDA presented comparable occlusal wear, but premolars in SDA tend to have higher probability for having occlusal wear. Fewer numbers of POPs were associated with more wear in anterior teeth. © 2013 John Wiley & Sons Ltd.

  8. The Integration of Occlusion and Disparity Information for Judging Depth in Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Smith, Danielle; Ropar, Danielle; Allen, Harriet A.

    2017-01-01

    In autism spectrum disorder (ASD), atypical integration of visual depth cues may be due to flattened perceptual priors or selective fusion. The current study attempts to disentangle these explanations by psychophysically assessing within-modality integration of ordinal (occlusion) and metric (disparity) depth cues while accounting for sensitivity…

  9. A Novel Technique of a Transcorneal Suture to Manage an Iris Tuck into the Tube of a Glaucoma Drainage Device.

    PubMed

    Kataria, Pankaj; Kaushik, Sushmita; Singh, Simar R; Pandav, Surinder S

    2016-08-01

    Glaucoma drainage devices create an alternative pathway of aqueous drainage from the anterior chamber by channelling aqueous out of the eye through a tube to a subconjunctival bleb or the suprachoroidal space. They may be associated with a number of potential complications including tube malpositioning. This malpositioning may have serious sequelae such as corneal endothelial damage, chronic iritis, tube iris touch, cataract formation, or tube occlusion. Occlusion of the mouth of the tube by the iris impedes aqueous drainage and results in the failure of intraocular pressure (IOP) control. Tube repositioning in cases of occlusion of the mouth of the tube by the iris often involves extensive and potentially complicated surgery requiring tube removal and reinsertion. We describe a new minimally invasive surgical technique for correcting posterior tube malposition resulting in tube occlusion by the iris. The iris had occluded the tube of a Baerveldt prototype glaucoma drainage devices and caused an intractable increased IOP. After our tube sling suture, the tube was free, and the IOP normalized. The procedure entailed no difficult dissection or major surgical intervention. The technique is illustrated by a surgical video. This novel technique is a simple method that relieved the occlusion successfully, and avoided the need to redissect the conjunctiva or shorten the tube.

  10. Redundant drive current imbalance problem of the Automatic Radiator Inspection Device (ARID)

    NASA Technical Reports Server (NTRS)

    Latino, Carl D.

    1992-01-01

    The Automatic Radiator Inspection Device (ARID) is a 4 Degree of Freedom (DOF) robot with redundant drive motors at each joint. The device is intended to automate the labor intensive task of space shuttle radiator inspection. For safety and redundancy, each joint is driven by two independent motor systems. Motors driving the same joint, however, draw vastly different currents. The concern was that the robot joints could be subjected to undue stress. It was the objective of this summer's project to determine the cause of this current imbalance. In addition it was to determine, in a quantitative manner, what was the cause, how serious the problem was in terms of damage or undue wear to the robot and find solutions if possible. It was concluded that most problems could be resolved with a better motor control design. This document discusses problems encountered and possible solutions.

  11. Pulmonary veno-occlusive disease and pulmonary capillary hemangiomatosis.

    PubMed

    Ortiz-Bautista, Carlos; Hernández-González, Ignacio; Escribano-Subías, Pilar

    2017-03-22

    Pulmonary veno-occlusive disease is a rare cause of pulmonary hypertension which is part, together with pulmonary capillary hemangiomatosis, of the special designation (subgroup 1') within pulmonary hypertension group 1 in the latest classification of the pulmonary hypertension World Symposium. Recent discovery that gene mutations in eukaryotic translation initiation factor 2 alpha kinase 4 (EIF2AK4) are responsible for inherited forms of pulmonary veno-occlusive disease has changed the role of genetic testing, acquiring relevant importance in the diagnosis of these patients. Despite the advances in genetic, cellular and molecular basis knowledge in the last decade, pulmonary veno-occlusive disease remains as a rare aetiology of pulmonary hypertension without any effective medical treatment approved and poor outcomes. This document aims to review the advances occurred in the understanding of pulmonary veno-occlusive disease in the last years. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  12. A change in humidification system can eliminate endotracheal tube occlusion.

    PubMed

    Doyle, Alex; Joshi, Manasi; Frank, Peter; Craven, Thomas; Moondi, Parvez; Young, Peter

    2011-12-01

    Inadequate airway humidification can result in endotracheal tube occlusion. There is evidence that heat and moisture exchangers (HMEs) are more prone to endotracheal tube occlusion than heated humidifiers (HHs) that contain a heated wire circuit. We aimed to compare the incidence of endotracheal tube occlusion while introducing a new dual-heated wire circuit HH in place of an established hydrophobic HME. This was a prospective observational study. All patients who required intubation were included in our analysis. Univariate statistical analysis was performed using a Fisher exact test. P < .05 was considered statistically significant. There were 158 patients in the HME group and 88 patients in the HH group. The incidence of endotracheal tube occlusion was 5.7% in the HME group and 0% in the HH group. Statistical analysis revealed a significant difference between the 2 groups (P = .02). In light of this finding, we changed our practice to provide humidification exclusively by HH. In the subsequent 18-month period, there were no further episodes of endotracheal tube occlusion. Our study demonstrates that there is a significant increase in the incidence of endotracheal tube occlusion when using a hydrophobic HME compared with an HH and that using a dual-heated wire circuit HH can eliminate endotracheal tube occlusion. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. External Mechanical Devices and Vascular Surgery for Erectile Dysfunction.

    PubMed

    Trost, Landon W; Munarriz, Ricardo; Wang, Run; Morey, Allen; Levine, Laurence

    2016-11-01

    The field of sexual medicine is continuously advancing, with novel outcomes reported on a regular basis. Given the rapid evolution, updated guidelines are essential to inform practicing clinicians on best practices. To summarize the current literature and provide clinical guidelines on penile traction therapy, vacuum erection devices, and penile revascularization. A consensus panel was held with leading sexual medicine experts during the 2015 International Consultation on Sexual Medicine (ICSM). Relevant literature was reviewed and graded based on Oxford criteria to develop evidence-based guideline and consensus statements. The development of clinically relevant guidelines. Penile traction therapy is a viable therapy to modestly improve penile length as a primary therapy, before penile prosthesis placement in men with decreased penile length or after surgery for Peyronie's disease. It also might have a role in the acute phase of Peyronie's disease but has inconsistent outcomes in the long-term phase. Vacuum erection devices are effective in creating an erection satisfactory for intercourse, even in difficult-to-treat populations. They also might be used in the post-prostatectomy setting to maintain penile length but have insufficient evidence as a penile rehabilitation therapy. For vasculogenic erectile dysfunction, men with suspected arterial insufficiency can be evaluated with penile Duplex Doppler ultrasonography and confirmatory angiography. Penile revascularization procedures have consistently demonstrated benefits in very select patient populations; however, inadequate data exists to suggest the superiority of one technique. Men with vascular risk factors are likely poor candidates for penile revascularization, although veno-occlusive dysfunction and age are less significant. Therapies for treating primary veno-occlusive dysfunction are not recommended and should be reserved for clinical trials. Since the prior ICSM meeting, multiple developments have

  14. Impact of the Intracoronary Rendezvous technique on coronary angioplasty for chronic total occlusion.

    PubMed

    Nihei, Taro; Yamamoto, Yoshito; Kudo, Shun; Hanawa, Kenichiro; Hasebe, Yuhi; Takagi, Yusuke; Minatoya, Yutaka; Sugi, Masafumi; Shimokawa, Hiroaki

    2017-10-01

    The Rendezvous technique, which requires bidirectional wiring, is one of the useful methods for improving the success rate of recanalization for chronic total occlusion (CTO) in the field of peripheral intervention. Recently, advanced new devices for percutaneous coronary intervention have enabled us to perform the Rendezvous technique for peripheral as well as for coronary CTO lesions. We used the Intracoronary Rendezvous technique to perform angioplasty for coronary CTO. "Intracoronary Rendezvous" means that Rendezvous was achieved within the CTO lesion. From March 2009 to November 2015, 189 patients underwent CTO angioplasty at our institute, and we treated 10 patients with the Intracoronary Rendezvous technique. This technique involves crossing the Gaia series guidewire to the contralateral Corsair microcatheter located inside the plaque of CTO lesions. The majority of the CTO sites examined were in the proximal RCA (60 %). Lesion length of the occlusion was relatively long (64.4 ± 12.2 mm). Using the biplane imaging system, we were able to control the Gaia guidewires in a specific direction. Furthermore, if the antegrade and retrograde wires can be advanced into contiguous space inside the CTO lesion, we intentionally entered either wire into the contralateral Corsair microcatheter, followed by successful CTO crossing. CTO recanalization was completed for all patients without controlled antegrade retrograde subintimal tracking (CART) or reverse CART. No major complications occurred during hospitalization. These results indicate that the Rendezvous technique, assisted by new devices and a biplane imaging system, represents one of the primary options to achieve successful coronary CTO recanalization.

  15. Occlusal accommodation and mouthguards for prevention of orofacial trauma.

    PubMed

    Geary, Julian Lindsay; Clifford, Thomas Joseph; Kinirons, Martin James

    2009-01-01

    The aim of this study was to investigate the effect of two types of occlusal accommodation on the arch separation in centric and eccentric arch positions and to assess the opposing tooth contacts in professionally made, thermoformed sports mouthguards. Maxillary and mandibular alginate impressions, a wax interocclusal record of centric occlusion together with maxillary/condylar face-bow registrations, were recorded clinically for 10 undergraduate dental students who are sports activist volunteers of the School of Medicine and Dentistry, Queen's University Belfast. Two ethylene vinyl acetate thermoformed maxillary mouthguards were made for each player (N = 20) using a standardised procedure. Ten mouthguards served both as the control (i.e. the non-accommodated) group and also the accommodated, occlusally 'imprinted' group. The other 10 mouthguards served as the accommodated, occlusally 'ground' group. Casts were articulated, each non-accommodated and accommodated mouthguard was seated and the extent of the interocclusal opening was recorded in all three arch relationships. The number of mouthguard and mandibular tooth contacts were also recorded in each position. The increased vertical occlusal dimension that was found in the presence of non-accommodated mouthguards equated to the full-sheet thickness of the material that was used to form the mouthguards. Only mouthguards accommodated by grinding retained high levels of occlusal contact in all arch relationships that were tested. Within the limitations of this study, the modification of the occlusal surface made by flat grinding reduced the arch separation in eccentric movements and increased the opposing tooth contacts in custom-made mouthguards. This may contribute to increased comfort, compliance and the protective effect of these appliances thus resulting in a reduction of injuries to the teeth, arches and soft tissues.

  16. Multi-scale Visualization of Molecular Architecture Using Real-Time Ambient Occlusion in Sculptor.

    PubMed

    Wahle, Manuel; Wriggers, Willy

    2015-10-01

    The modeling of large biomolecular assemblies relies on an efficient rendering of their hierarchical architecture across a wide range of spatial level of detail. We describe a paradigm shift currently under way in computer graphics towards the use of more realistic global illumination models, and we apply the so-called ambient occlusion approach to our open-source multi-scale modeling program, Sculptor. While there are many other higher quality global illumination approaches going all the way up to full GPU-accelerated ray tracing, they do not provide size-specificity of the features they shade. Ambient occlusion is an aspect of global lighting that offers great visual benefits and powerful user customization. By estimating how other molecular shape features affect the reception of light at some surface point, it effectively simulates indirect shadowing. This effect occurs between molecular surfaces that are close to each other, or in pockets such as protein or ligand binding sites. By adding ambient occlusion, large macromolecular systems look much more natural, and the perception of characteristic surface features is strongly enhanced. In this work, we present a real-time implementation of screen space ambient occlusion that delivers realistic cues about tunable spatial scale characteristics of macromolecular architecture. Heretofore, the visualization of large biomolecular systems, comprising e.g. hundreds of thousands of atoms or Mega-Dalton size electron microscopy maps, did not take into account the length scales of interest or the spatial resolution of the data. Our approach has been uniquely customized with shading that is tuned for pockets and cavities of a user-defined size, making it useful for visualizing molecular features at multiple scales of interest. This is a feature that none of the conventional ambient occlusion approaches provide. Actual Sculptor screen shots illustrate how our implementation supports the size-dependent rendering of molecular

  17. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    PubMed Central

    Kothari, Mihir

    2014-01-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa. PMID:23571255

  18. Occlusion-amblyopia following high dose oral levodopa combined with part time patching.

    PubMed

    Kothari, Mihir

    2014-12-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  19. Combined Central Retinal Vein and Branch Retinal Artery Occlusion Post Intense Physical Activity.

    PubMed

    Coca, Mircea; Tecle, Nahom; Amde, Wendewessen; Mehta, Ankur

    2017-08-23

    We report a case of combined central retinal vein occlusion and branch retinal artery occlusion. A previously healthy 47-year-old male presented with decreased vision in the right eye after completing a half marathon. A fundus exam and retinal imaging revealed a combined central retinal vein and branch retinal artery occlusion. In the present report, we review the literature and discuss the possible mechanisms behind combined retinal vessel occlusions. To our knowledge, this is the first reported case of combined central retinal vein occlusion and branch retinal artery occlusion following intense exercise.

  20. Combined Central Retinal Vein and Branch Retinal Artery Occlusion Post Intense Physical Activity

    PubMed Central

    Tecle, Nahom; Amde, Wendewessen; Mehta, Ankur

    2017-01-01

    We report a case of combined central retinal vein occlusion and branch retinal artery occlusion. A previously healthy 47-year-old male presented with decreased vision in the right eye after completing a half marathon. A fundus exam and retinal imaging revealed a combined central retinal vein and branch retinal artery occlusion. In the present report, we review the literature and discuss the possible mechanisms behind combined retinal vessel occlusions. To our knowledge, this is the first reported case of combined central retinal vein occlusion and branch retinal artery occlusion following intense exercise. PMID:29067224

  1. Direct current force sensing device based on compressive spring, permanent magnet, and coil-wound magnetostrictive/piezoelectric laminate.

    PubMed

    Leung, Chung Ming; Or, Siu Wing; Ho, S L

    2013-12-01

    A force sensing device capable of sensing dc (or static) compressive forces is developed based on a NAS106N stainless steel compressive spring, a sintered NdFeB permanent magnet, and a coil-wound Tb(0.3)Dy(0.7)Fe(1.92)/Pb(Zr, Ti)O3 magnetostrictive∕piezoelectric laminate. The dc compressive force sensing in the device is evaluated theoretically and experimentally and is found to originate from a unique force-induced, position-dependent, current-driven dc magnetoelectric effect. The sensitivity of the device can be increased by increasing the spring constant of the compressive spring, the size of the permanent magnet, and/or the driving current for the coil-wound laminate. Devices of low-force (20 N) and high-force (200 N) types, showing high output voltages of 262 and 128 mV peak, respectively, are demonstrated at a low driving current of 100 mA peak by using different combinations of compressive spring and permanent magnet.

  2. Intravitreous Bevacizumab in the Treatment of Macuar Edema from Branch Retinal Vein Occlusion and Hemisphere Retinal Vein Occlusion (An AOS Thesis)

    PubMed Central

    Fish, Gary Edd

    2008-01-01

    Purpose To compare intravitreous bevacizumab to other current treatments of branch retinal vein occlusion (BRVO) and hemisphere retinal vein occlusion (HRVO) with consideration to visual outcome, cost, convenience, and risk of treatment. Methods This is a retrospective chart review from a large referral retina practice. The data comprise 56 patients with BRVO and HRVO treated by intravitreous bevacizumab, with and without intravitreous triamcinolone acetonide. Initial visual acuities at the time of first bevacizumab injection, best acuities through the follow-up time, final acuity at last visit before review, initial macular thickness, and final macular thickness were measured. Changes in vision and thickness were calculated, as were the percentage of eyes improving, stabilizing, and worsening. Results The data were compared to composite data derived from several current treatments of BRVO. The subgroup of 39 eyes that received only bevacizumab without triamcinolone acetonide had the most improvement in vision. The median change in visual acuity was 1.5 lines (P = .012) over a mean follow-up of 8.8 months. Twenty-three eyes (59%) improved visually, with 20 eyes (51%) improving 2 or more lines. These results are similar to those for eyes that received argon grid laser and chorioretinal anastomosis, but are worse than in eyes that received arteriovenous adventitial sheathotomy, macular decompression surgery, and intravitreous triamcinolone acetonide. Conclusions Visual benefit from intravitreous bevacizumab compares well against laser treatments for BRVO and HRVO but not as well opposed to surgical techniques and intravitreous triamcinolone acetonide. Intravitreous bevacizumab injection has a risk, cost, and convenience profile that is favorable. PMID:19277242

  3. Pulmonary Capillary Hemangiomatosis and Pulmonary Veno-occlusive Disease.

    PubMed

    Chaisson, Neal F; Dodson, Mark W; Elliott, Charles Gregory

    2016-09-01

    This article provides an overview of pulmonary veno-occlusive disease (PVOD) and pulmonary capillary hemangiomatosis (PCH), two disorders that challenge clinicians, radiologists, and pathologists because they often mimic pulmonary arterial hypertension (PAH). The article reviews the features that differentiate PVOD and PCH from PAH. The article also describes the overlap of PVOD and PCH, highlighted by recent reports of families diagnosed with PVOD or PCH caused by EIF2AK4 mutations. In addition, the article outlines current approaches to the diagnosis and treatment of PVOD and PCH. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Biomechanical factors related to occlusal load transfer in removable complete dentures.

    PubMed

    Żmudzki, Jarosław; Chladek, Grzegorz; Kasperski, Jacek

    2015-08-01

    Owing to economic conditions, removable dentures remain popular despite the discomfort and reduced chewing efficiency experienced by most denture wearers. However, there is little evidence to confirm that the level of mucosal load exceeds the pressure pain threshold. This discrepancy stimulated us to review the current state of knowledge on the biomechanics of mastication with complete removable dentures. The loading beneath dentures was analyzed in the context of denture foundation characteristics, salivary lubrication, occlusal forces, and the biomechanics of mastication. The analysis revealed that the interpretation of data collected in vivo is hindered due to the simultaneous overlapping effects of many variables. In turn, problems with determining the pressure beneath a denture and analyzing frictional processes constitute principal limitations of in vitro model studies. Predefined conditions of finite element method simulations should include the effects of oblique mastication forces, simultaneous detachment and sliding of the denture on its foundation, and the stabilizing role of balancing contacts. This review establishes that previous investigations may have failed because of their unsubstantiated assumption that, in a well-working balanced occlusion, force is only exerted perpendicular to the occlusal plane, allowing the denture to sit firmly on its foundation. Recent improvements in the simulation of realistic biomechanical denture behavior raise the possibility of assessing the effects of denture design on the pressures and slides beneath the denture.

  5. Indoor anti-occlusion visible light positioning systems based on particle filtering

    NASA Astrophysics Data System (ADS)

    Jiang, Meng; Huang, Zhitong; Li, Jianfeng; Zhang, Ruqi; Ji, Yuefeng

    2015-04-01

    As one of the most popular categories of mobile services, a rapid growth of indoor location-based services has been witnessed over the past decades. Indoor positioning methods based on Wi-Fi, radio-frequency identification or Bluetooth are widely commercialized; however, they have disadvantages such as low accuracy or high cost. An emerging method using visible light is under research recently. The existed visible light positioning (VLP) schemes using carrier allocation, time allocation and multiple receivers all have limitations. This paper presents a novel mechanism using particle filtering in VLP system. By this method no additional devices are needed and the occlusion problem in visible light would be alleviated which will effectively enhance the flexibility for indoor positioning.

  6. Nitride based quantum well light-emitting devices having improved current injection efficiency

    DOEpatents

    Tansu, Nelson; Zhao, Hongping; Liu, Guangyu; Arif, Ronald

    2014-12-09

    A III-nitride based device provides improved current injection efficiency by reducing thermionic carrier escape at high current density. The device includes a quantum well active layer and a pair of multi-layer barrier layers arranged symmetrically about the active layer. Each multi-layer barrier layer includes an inner layer abutting the active layer; and an outer layer abutting the inner layer. The inner barrier layer has a bandgap greater than that of the outer barrier layer. Both the inner and the outer barrier layer have bandgaps greater than that of the active layer. InGaN may be employed in the active layer, AlInN, AlInGaN or AlGaN may be employed in the inner barrier layer, and GaN may be employed in the outer barrier layer. Preferably, the inner layer is thin relative to the other layers. In one embodiment the inner barrier and active layers are 15 .ANG. and 24 .ANG. thick, respectively.

  7. Feasibility of self-structured current accessed bubble devices in spacecraft recording systems

    NASA Technical Reports Server (NTRS)

    Nelson, G. L.; Krahn, D. R.; Dean, R. H.; Paul, M. C.; Lo, D. S.; Amundsen, D. L.; Stein, G. A.

    1985-01-01

    The self-structured, current aperture approach to magnetic bubble memory is described. Key results include: (1) demonstration that self-structured bubbles (a lattice of strongly interacting bubbles) will slip by one another in a storage loop at spacings of 2.5 bubble diameters, (2) the ability of self-structured bubbles to move past international fabrication defects (missing apertures) in the propagation conductors (defeat tolerance), and (3) moving bubbles at mobility limited speeds. Milled barriers in the epitaxial garnet are discussed for containment of the bubble lattice. Experimental work on input/output tracks, storage loops, gates, generators, and magneto-resistive detectors for a prototype device are discussed. Potential final device architectures are described with modeling of power consumption, data rates, and access times. Appendices compare the self-structured bubble memory from the device and system perspectives with other non-volatile memory technologies.

  8. Improving prediction of recanalization in acute large-vessel occlusive stroke.

    PubMed

    Vanacker, P; Lambrou, D; Eskandari, A; Maeder, P; Meuli, R; Ntaios, G; Michel, P

    2014-06-01

    Recanalization in acute ischemic stroke with large-vessel occlusion is a potent indicator of good clinical outcome. To identify easily available clinical and radiologic variables predicting recanalization at various occlusion sites. All consecutive, acute stroke patients from the Acute STroke Registry and Analysis of Lausanne (2003-2011) who had a large-vessel occlusion on computed tomographic angiography (CTA) (< 12 h) were included. Recanalization status was assessed at 24 h (range: 12-48 h) with CTA, magnetic resonance angiography, or ultrasonography. Complete and partial recanalization (corresponding to the modified Treatment in Cerebral Ischemia scale 2-3) were grouped together. Patients were categorized according to occlusion site and treatment modality. Among 439 patients, 51% (224) showed complete or partial recanalization. In multivariate analysis, recanalization of any occlusion site was most strongly associated with endovascular treatment, including bridging therapy (odds ratio [OR] 7.1, 95% confidence interval [CI] 2.2-23.2), and less so with intravenous thrombolysis (OR 1.6, 95% CI 1.0-2.6) and recanalization treatments performed beyond guidelines (OR 2.6, 95% CI 1.2-5.7). Clot location (large vs. intermediate) and tandem pathology (the combination of intracranial occlusion and symptomatic extracranial stenosis) were other variables discriminating between recanalizers and non-recanalizers. For patients with intracranial occlusions, the variables significantly associated with recanalization after 24 h were: baseline National Institutes of Health Stroke Scale (NIHSS) (OR 1.04, 95% CI 1.02-1.1), Alberta Stroke Program Early CT Score (ASPECTS) on initial computed tomography (OR 1.2, 95% CI 1.1-1.3), and an altered level of consciousness (OR 0.2, 95% CI 0.1-0.5). Acute endovascular treatment is the single most important factor promoting recanalization in acute ischemic stroke. The presence of extracranial vessel stenosis or occlusion decreases

  9. Stroke treatment academic industry roundtable: research priorities in the assessment of neurothrombectomy devices.

    PubMed

    Saver, Jeffrey L; Jovin, Tudor G; Smith, Wade S; Albers, Gregory W; Baron, Jean-Claude; Boltze, Johannes; Broderick, Joseph P; Davis, Lisa A; Demchuk, Andrew M; DeSena, Salvatore; Fiehler, Jens; Gorelick, Philip B; Hacke, Werner; Holt, Bill; Jahan, Reza; Jing, Hui; Khatri, Pooja; Kidwell, Chelsea S; Lees, Kennedy R; Lev, Michael H; Liebeskind, David S; Luby, Marie; Lyden, Patrick; Megerian, J Thomas; Mocco, J; Muir, Keith W; Rowley, Howard A; Ruedy, Richard M; Savitz, Sean I; Sipelis, Vitas J; Shimp, Samuel K; Wechsler, Lawrence R; Wintermark, Max; Wu, Ona; Yavagal, Dileep R; Yoo, Albert J

    2013-12-01

    The goal of the Stroke Treatment Academic Industry Roundtable (STAIR) meetings is to advance the development of stroke therapies. At STAIR VIII, consensus recommendations were developed for clinical trial strategies to demonstrate the benefit of endovascular reperfusion therapies for acute ischemic stroke. Prospects for success with forthcoming endovascular trials are robust, because new neurothrombectomy devices have superior reperfusion efficacy compared with earlier-generation interventions. Specific recommendations are provided for trial designs in 3 populations: (1) patients undergoing intravenous fibrinolysis, (2) early patients ineligible for or having failed intravenous fibrinolysis, and (3) wake-up and other late-presenting patients. Among intravenous fibrinolysis-eligible patients, key principles are that CT or MRI confirmation of target arterial occlusions should precede randomization; endovascular intervention should be pursued with the greatest rapidity possible; and combined intravenous and neurothrombectomy therapy is more promising than neurothrombectomy alone. Among patients ineligible for or having failed intravenous fibrinolysis, scientific equipoise was affirmed and the need to randomize all eligible patients emphasized. Vessel imaging to confirm occlusion is mandatory, and infarct core and penumbral imaging is desirable in later time windows. Additional STAIR VIII recommendations include approaches to test multiple devices in a single trial, utility weighting of disability end points, and adaptive designs to delineate time and tissue injury thresholds at which benefits from intervention no longer accrue. Endovascular research priorities in acute ischemic stroke are to perform trials testing new, highly effective neuro thrombectomy devices rapidly deployed in patients confirmed to have target vessel occlusions.

  10. New methodology to assess activity status of occlusal caries in primary teeth using laser fluorescence device.

    PubMed

    Braga, Mariana Minatel; de Benedetto, Monique Saveriano; Imparato, Jose Carlos Pettorossi; Mendes, Fausto Medeiros

    2010-01-01

    An in vivo study was conducted to verify the ability of laser fluorescence (LF) to assess the activity status of occlusal caries in primary teeth, using different air-drying times. Occlusal sites (707) were examined using LF (DIAGNOdent) after air-drying for 3 s and 15 s, and the difference between readings (DIF15 s-3 s) was calculated. For concurrent validation of LF, visual criteria-Nyvad (NY) and Lesion Activity Assessment associated with the International Caries Detection and Assessment System (LAA-ICDAS)-were the reference standards for lesion activity. Histological exam using a pH-indicator dye (0.1% methyl red) was performed in 46 exfoliated/extracted teeth for criterion validation. LF readings and DIF15 s-3 s were compared using Kruskall-Wallis and Mann-Whitney tests. Receiver operating characteristic analyses were performed and validity parameters calculated, considering the caries activity assessment. Using NY, active lesions (3 s: 30.0+/-29.3; 15 s: 34.2+/-30.6) presented higher LF readings than inactive lesions (3 s: 17.0+/-16.3; 15 s: 19.2+/-17.3; p<0.05), different from LAA-ICDAS. Active cavitated caries resulted in higher LF readings (3 s: 50.3+/-3.5; 15 s: 54.7+/-30.2) than inactive cavitated caries (3 s: 19.9+/-16.3; 15 s: 22.8+/-16.8). Therefore, LF can distinguish cavitated active and inactive lesions classified by NY, but not by LAA-ICDAS; however, this difference might be related to the visual system rather than to LF. The air-drying time could be an alternative to improve the caries activity assessment; however, longer air-drying time is suggested to be tested subsequently.

  11. Levodopa-carbidopa with occlusion in older children with amblyopia.

    PubMed

    Bhartiya, Prashant; Sharma, Pradeep; Biswas, Nihar R; Tandon, Radhika; Khokhar, Sudarshan K

    2002-12-01

    To study the role of levodopa-carbidopa in supplementing occlusion therapy in older children with strabismic or anisometropic amblyopia. A clinical study was performed on 40 amblyopic children (19 strabismic and 21 anisometropic), 6 to 18 years old (mean age, 10.9 years). They received an average dose of 1.86 mg/kg/day (1.33-2.36 mg/kg/day) of levodopa and carbidopa (4:1 ratio) or a placebo in 3 divided doses over a 4-week period, combined with full-time occlusion. The occlusion was continued for the study duration of 3 months. Early Treatment Diabetic Retinopathy Study visual acuity charts and Cambridge low-contrast gratings for contrast sensitivity (CS) were used to assess visual functions. Tolerance and compliance with occlusion and capsule consumption were assessed. Visual acuity of the nonamblyopic eye did not deteriorate during the study in either group. CS decreased by 22 units in the levodopa group and increased in the placebo group by 53 units at the first month. The CS in the levodopa group recovered later by the third month of follow-up. Both the levodopa and the placebo groups showed significant improvement in visual function in the amblyopic eye (P <.001). Overall changes in logarithm of minimum angle of resolution values and CS in the amblyopic eyes were similar in both groups (P >.05). Strabismic and anisometropic amblyopes did not behave differently. Drug tolerance, occlusion compliance, and capsule ingestion compliance were similar between the groups, with no significant side effects. Clinically, levodopa supplementation does not offer any advantage over occlusion alone. Moreover, the risk of occlusion amblyopia could increase with the use of drugs like levodopa that might affect the plasticity of the visual cortex.

  12. Hypothalamic digoxin, hemispheric chemical dominance, and mesenteric artery occlusion.

    PubMed

    Kurup, Ravi Kumar; Kurup, Paramesware Achutha

    2003-12-01

    The role of the isoprenoid pathway in vascular thrombosis, especially mesenteric artery occlusion and its relation to hemispheric dominance, was assessed in this study. The following parameters were measured in patients with mesenteric artery occlusion and individuals with right hemispheric, left hemispheric, and bihemispheric dominance: (1) plasma HMG CoA reductase, digoxin, dolichol, ubiquinone, and magnesium levels; (2) tryptophan/tyrosine catabolic patterns; (3) free radical metabolism; (4) glycoconjugate metabolism; and (5) membrane composition. In patients with mesenteric artery occlusion there was elevated digoxin synthesis, increased dolichol and glycoconjugate levels, low ubiquinone, and elevated free radical levels. The RBC membrane Na(+)-K+ ATPase activity and serum magnesium were decreased. There was also an increase in tryptophan catabolites and reduction in tyrosine catabolites in the serum. There was an increase in cholesterol:phospholipid ratio and a reduction in glycoconjugate level of RBC membrane in these patients. The biochemical patterns obtained in mesenteric artery occlusion is similar to those obtained in left-handed/right hemispheric dominant individuals by the dichotic listening test. But all the patients with mesenteric artery occlusion were right-handed/left hemispheric dominant by the dichotic listening test. Hemispheric chemical dominance has no correlation with handedness or the dichotic listening test. Mesenteric artery occlusion occurs in right hemispheric chemically dominant individuals and is a reflection of altered brain function. Hemispheric chemical dominance may thus control the risk for developing vascular thrombosis in individuals.

  13. Polymeric salt bridges for conducting electric current in microfluidic devices

    DOEpatents

    Shepodd, Timothy J [Livermore, CA; Tichenor, Mark S [San Diego, CA; Artau, Alexander [Humacao, PR

    2009-11-17

    A "cast-in-place" monolithic microporous polymer salt bridge for conducting electrical current in microfluidic devices, and methods for manufacture thereof is disclosed. Polymeric salt bridges are formed in place in capillaries or microchannels. Formulations are prepared with monomer, suitable cross-linkers, solvent, and a thermal or radiation responsive initiator. The formulation is placed in a desired location and then suitable radiation such as UV light is used to polymerize the salt bridge within a desired structural location. Embodiments are provided wherein the polymeric salt bridges have sufficient porosity to allow ionic migration without bulk flow of solvents therethrough. The salt bridges form barriers that seal against fluid pressures in excess of 5000 pounds per square inch. The salt bridges can be formulated for carriage of suitable amperage at a desired voltage, and thus microfluidic devices using such salt bridges can be specifically constructed to meet selected analytical requirements.

  14. Increased carboxyhemoglobin level during liver resection with inflow occlusion.

    PubMed

    Godai, Kohei; Hasegawa-Moriyama, Maiko; Kuniyoshi, Tamotsu; Matsunaga, Akira; Kanmura, Yuichi

    2013-04-01

    Controlling stress responses associated with ischemic changes due to bleeding and ischemia/reperfusion injury is essential for anesthetic management. Endogenous carboxyhemoglobin (COHb) is produced in the oxidative degradation of heme proteins by the stress-response enzyme heme oxygenase. Although the COHb level is elevated in critically ill patients, changes in endogenous COHb during anesthesia have not been well investigated. Therefore, we evaluated changes in endogenous COHb levels in patients undergoing liver resections with inflow occlusion. Levels of COHb were significantly increased after the Pringle maneuver. The inflow occlusion time in patients with increased COHb after the Pringle maneuver (∆COHb > 0.3 %) was significantly longer than in patients without increased COHb (∆COHb < 0.3 %) (P = 0.01). In addition, COHb changes were correlated with inflow occlusion time (P = 0.005, R(2) = 0.21). Neither total blood loss, transfusion volume of packed red blood cells, operation time, nor anesthetic time differed between patients with and without increased COHb. The results indicated that endogenous COHb levels were increased by inflow occlusion in patients undergoing liver resections, which suggests that changes in COHb may correlate with hepatic ischemia/reperfusion injury induced by inflow occlusion.

  15. Complete occlusion after blunt injury to the abdominal aorta.

    PubMed

    Meghoo, Colin A L; Gonzalez, Ernest A; Tyroch, Alan H; Wohltmann, Christopher D

    2003-10-01

    Injury to the abdominal aorta after blunt trauma is uncommon. When this injury results in complete vessel occlusion, the presentation is dramatic. Timely intervention is essential. After a case report, we examined all reported cases of complete occlusion after blunt injury to the abdominal aorta and reviewed the cause, presentation, and management of this injury. Complete vessel occlusion arises from intimal injury. The most frequent mechanism is compression from a seat belt or steering wheel during a motor vehicle crash. Patients present with absent femoral and distal pulses in association with lower extremity neuropathy. Intervention commonly involves bypass grafting of the abdominal aorta. Complete occlusion after blunt trauma to the abdominal aorta is rare. Neurologic deficits most commonly arise from peripheral nerve ischemia. Reperfusion within 6 hours confers a greater chance of limb salvage and neurologic recovery.

  16. Aphid watery saliva counteracts sieve-tube occlusion: a universal phenomenon?

    PubMed

    Will, Torsten; Kornemann, Sarah R; Furch, Alexandra C U; Tjallingii, W Fred; van Bel, Aart J E

    2009-10-01

    Ca2+-binding proteins in the watery saliva of Megoura viciae counteract Ca2+-dependent occlusion of sieve plates in Vicia faba and so prevent the shut-down of food supply in response to stylet penetration. The question arises whether this interaction between aphid saliva and sieve-element proteins is a universal phenomenon as inferred by the coincidence between sieve-tube occlusion and salivation. For this purpose, leaf tips were burnt in a number of plant species from four different families to induce remote sieve-plate occlusion. Resultant sieve-plate occlusion in these plant species was counteracted by an abrupt switch of aphid behaviour. Each of the seven aphid species tested interrupted its feeding behaviour and started secreting watery saliva. The protein composition of watery saliva appeared strikingly different between aphid species with less than 50% overlap. Secretion of watery saliva seems to be a universal means to suppress sieve-plate occlusion, although the protein composition of watery saliva seems to diverge between species.

  17. Impact of the Occlusion Duration on the Performance of J-CTO Score in Predicting Failure of Percutaneous Coronary Intervention for Chronic Total Occlusion.

    PubMed

    de Castro-Filho, Antonio; Lamas, Edgar Stroppa; Meneguz-Moreno, Rafael A; Staico, Rodolfo; Siqueira, Dimytri; Costa, Ricardo A; Braga, Sergio N; Costa, J Ribamar; Chamié, Daniel; Abizaid, Alexandre

    2017-06-01

    The present study examined the association between Multicenter CTO Registry in Japan (J-CTO) score in predicting failure of percutaneous coronary intervention (PCI) correlating with the estimated duration of chronic total occlusion (CTO). The J-CTO score does not incorporate estimated duration of the occlusion. This was an observational retrospective study that involved all consecutive procedures performed at a single tertiary-care cardiology center between January 2009 and December 2014. A total of 174 patients, median age 59.5 years (interquartile range [IQR], 53-65 years), undergoing CTO-PCI were included. The median estimated occlusion duration was 7.5 months (IQR, 4.0-12.0 months). The lesions were classified as easy (score = 0), intermediate (score = 1), difficult (score = 2), and very difficult (score ≥3) in 51.1%, 33.9%, 9.2%, and 5.7% of the patients, respectively. Failure rate significantly increased with higher J-CTO score (7.9%, 20.3%, 50.0%, and 70.0% in groups with J-CTO scores of 0, 1, 2, and ≥3, respectively; P<.001). There was no significant difference in success rate according to estimated duration of occlusion (P=.63). Indeed, J-CTO score predicted failure of CTO-PCI independently of the estimated occlusion duration (P=.24). Areas under receiver-operating characteristic curves were computed and it was observed that for each occlusion time period, the discriminatory capacity of the J-CTO score in predicting CTO-PCI failure was good, with a C-statistic >0.70. The estimated duration of occlusion had no influence on the J-CTO score performance in predicting failure of PCI in CTO lesions. The probability of failure was mainly determined by grade of lesion complexity.

  18. Genuine splenic artery aneurysm rupture treated by N‐butyl cyanoacrylate and metallic coils under resuscitative endovascular balloon occlusion of the aorta

    PubMed Central

    Hagiwara, Shuichi; Miyazaki, Masaya; Kaneko, Minoru; Murata, Masato; Nakajima, Jun; Ohyama, Yoshio; Tamura, Jun'ichi; Tsushima, Yoshito; Oshima, Kiyohiro

    2016-01-01

    Case A 66 year‐old woman who presented with sudden lower abdominal pain was transferred to our emergency room. Vital signs were stable on arrival at the hospital, but immediately became unstable. Systolic/diastolic blood pressure and heart rate were 66/33 mmHg and 70 b.p.m., respectively. Computed tomography scanning showed splenic artery aneurysm rupture and extravasation. The patient was treated non‐operatively and definitively by endovascular therapy comprising resuscitative endovascular occlusion of the aorta for hemodynamic control, N‐butyl cyanoacrylate, and metallic coils as an embolization material. Outcome On admission day 3, she was enrolled in another department and admission day 54, she was discharged. Conclusion Although resuscitative endovascular occlusion of the aorta and N‐butyl cyanoacrylate is known to be effective, the use of resuscitative endovascular occlusion of the aorta with transcatheter arterial embolization and N‐butyl cyanoacrylate for non‐traumatic bleeding has not previously been reported. By combining and adapting these devices, their applications in endovascular management may be increased. PMID:29123801

  19. Computer modeling of occlusal surfaces of posterior teeth with the CICERO CAD/CAM system.

    PubMed

    Olthoff, L W; Van Der Zel, J M; De Ruiter, W J; Vlaar, S T; Bosman, F

    2000-08-01

    Static and dynamic occlusal interference frequently needs to be corrected by selective grinding of the occlusal surface of conventional cast and ceramic-fused-to-metal restorations. CAD/CAM techniques allow control of the dimensional contours of these restorations. However, parameters responsible for the occlusal form need to be determined. In most articulators, these parameters are set as default values. Which technique is best for minimizing the introduction of occlusal interference in restorations has not been determined. This study investigated differences in crown structure of a crown designed in static occlusion (STA) with designs adapted for dynamic occlusal interferences. Therefore, values from an optoelectronic registration system (String-Condylocomp, KAVO), an occlusal generated path (OGP) technique and default settings (DEF) were used in the CICERO CAD/CAM system. Morphology of CON, DEF, and OGP crowns was compared with that of the STA crown with respect to differences in a buccolingual section and frequency of occlusal distances in an interocclusal range of 1 mm, measured from the occlusal surface of the crown. All crown types fulfilled the esthetic and morphologic criteria for restorations in clinical dentistry. Difference in the morphology of the OGP crown, compared with that of the STA crown, was greater than that for the CON and DEF crowns. These differences were seen especially in the distobuccal part of the occlusal surface; however, the number of occlusal contacts was considered sufficient to stabilize occlusion. Functional occlusion, adapted to dynamic occlusion in a CICERO crown for the first mandibular molar, can be obtained using data acquired with the String-Condylocomp registration system. The OGP technique was preferred to other techniques because of the simplicity of the technique for eliminating potential problems with opposing teeth during motion. However, this is achieved at the cost of fewer points of contact during occlusion than

  20. Intrarenal hemodynamic changes following acute partial renal arterial occlusion.

    DOT National Transportation Integrated Search

    1965-10-01

    Both an increase and a decrease in total renal vascular resistance, following a period of total renal artery occlusion, have been reported from this laboratory. The duration of the occlusive period and height of the perfusion pressure were found to p...

  1. Pulmonary veno-occlusive disease

    MedlinePlus

    ... disorder. Alternative Names Pulmonary vaso-occlusive disease Images Respiratory system References Chin K, Channick RN. Pulmonary hypertension. In: Broaddus VC, Mason RJ, Ernst JD, et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016: ...

  2. Continuous full-time occlusion of the sound eye vs full-time occlusion of the sound eye periodically alternating with occlusion of the amblyopic eye in treatment of amblyopia: a prospective randomized study.

    PubMed

    Stanković, B; Milenković, S

    2007-01-01

    To compare continuous full-time (24 hours per day) occlusion of the sound eye with full-time occlusion (24 hours per day) of the sound eye 1 day more than the years of age periodically alternating with occlusion of the amblyopic eye for 1 day, as treatments for profound strabismic amblyopia in children older than 5 years. A total of 53 patients with visual acuity (VA) of 0.4 and less in the amblyopic eye (tested by crowded Landolt Cs) after previously being provided optimal optical correction were randomly assigned to receive either of the two patching regimens. VA and pattern reversal visual evoked potentials (PVEP) were recorded prospectively at 1-month intervals. Improvement in VA and the reduction in crowding difficulties (CD) were the main outcome measures of the treatment efficiency. Both treatment modalities were equally effective. Of the 51 subjects who completed the study, 21 (41.2%) were cured whereas 32 (62.7%) attained satisfactory improvement. Recovery of VA was related to age, with cure being obtained in 23.5% (4/17) and satisfactory improvement in 52.9% (9/17) of patients older than 9 years. Larger gain in VA influenced the stability of the vision over time. It can be concluded that in clinically monitored parameters both treatment modalities were equally effective without any statistical or clinical significance in the observed groups of patients. However, events like the "trade-off" effect, occurrence of occlusion amblyopia, or prolongation of PVEP latency of the sound eye indicate that full-time continuous occlusion possibly presents a more effective form of treatment.

  3. Prefrontal Hemodynamic Changes Associated with Subjective Sense of Occlusal Discomfort

    PubMed Central

    Kobayashi, Goh; Hayama, Rika; Ikuta, Ryuhei; Onozouka, Minoru; Wake, Hiroyuki; Shimada, Atsushi; Shibuya, Tomoaki; Tamaki, Katsushi

    2015-01-01

    We used functional near-infrared spectroscopy to measure prefrontal brain activity accompanying the physical sensation of oral discomfort that arose when healthy young-adult volunteers performed a grinding motion with mild occlusal elevation (96 μm). We simultaneously evaluated various forms of occlusal discomfort using the visual analogue scale (VAS) and hemodynamic responses to identify the specific prefrontal activity that occurs with increased occlusal discomfort. The Oxy-Hb responses of selected channels in the bilateral frontopolar and dorsolateral prefrontal cortices increased in participants who reported increased severity of occlusal discomfort, while they decreased in those who reported no change or decreased occlusal discomfort during grinding. Moreover, the cumulative values of Oxy-Hb response in some of these channels were statistically significant predictive factors for the VAS scores. A generalized linear model analysis of Oxy-Hb signals in a group of participants who reported increased discomfort further indicated significant cerebral activation in the right frontopolar and dorsolateral prefrontal cortices that overlapped with the results of correlation analyses. Our results suggest that the increased hemodynamic responses in the prefrontal area reflect the top-down control of attention and/or self-regulation against the uncomfortable somatosensory input, which could be a possible marker to detect the subjective sense of occlusal discomfort. PMID:26090407

  4. [Closure of wide patent ductus arteriosus using a fenestrated muscular VSD occluder device in a pediatric patient with Down syndrome and pulmonary hypertension].

    PubMed

    Güvenç, Osman; Saygı, Murat; Demir, İbrahim Halil; Ödemiş, Ender

    2017-06-01

    Patients with wide patent ductus arteriosus and significant pulmonary hypertension not treated in time constitute a significant problem for cardiologists. For these patients, tests that could aid in decision-making for further planning include reversibility and balloon occlusion tests performed in the catheterization laboratory. Devices developed for the closure of ductus as well as different devices with off-label use may be employed in patients scheduled for transcatheter occlusion. When result of reversibility test is borderline positive, the use of fenestrated device may be applicable for selected patients. Presently described is case of a 10-year-old patient with Down syndrome who had a wide ductus and systemic pulmonary hypertension. Transcatheter closure procedure was performed with off-label use of a fenestrated muscular ventricular septal defect occluder device.

  5. Performance of current-in-plane pseudo-spin-valve devices on CMOS silicon-on-insulator underlayers

    NASA Astrophysics Data System (ADS)

    Katti, R. R.; Zou, D.; Reed, D.; Schipper, D.; Hynes, O.; Shaw, G.; Kaakani, H.

    2003-05-01

    Prior work has shown that current-in-plane (CIP) giant magnetoresistive (GMR) pseudo-spin-valve (PSV) devices grown on bulk Si wafers and bulk complementary metal-oxide semiconductor (CMOS) underlayers exhibit write and read characteristics that are suitable for application as nonvolatile memory devices. In this work, CIP GMR PSV devices fabricated on silicon-on-insulator CMOS underlayers are shown to support write and read performance. Reading and writing fields for selected devices are shown to be approximately 25%-50% that of unselected devices, which provides a margin for reading and writing specific bits in a memory without overwriting bits and without disturbing other bits. The switching characteristics of experimental devices were compared to and found to be similar with Landau-Lifschitz-Gilbert micromagnetic modeling results, which allowed inferring regions of reversible and irreversible rotations in magnetic reversal processes.

  6. Influence of Articulating Paper Thickness on Occlusal Contacts Registration: A Preliminary Report.

    PubMed

    Brizuela-Velasco, Aritza; Álvarez-Arenal, Ángel; Ellakuria-Echevarria, Joseba; del Río-Highsmith, Jaime; Santamaría-Arrieta, Gorka; Martín-Blanco, Nerea

    2015-01-01

    The objective of this preliminary study was to determine if the occlusal contact surface registered with an articulating paper during fixed prosthodontic treatment was contained within the area marked on a thicker articulating paper. This information would optimize any necessary occlusal adjustment of a prosthesis' veneering material. A convenience sample of 15 patients who were being treated with an implant-supported fixed singleunit dental prosthesis was selected. Occlusal registrations were obtained from each patient using 12-μm, 40-μm, 80-μm, and 200-μm articulating paper. Photographs of the occlusal registrations were obtained, and pixel measurements of the surfaces were taken and overlapped for comparison. The results showed that the thicker the articulating paper, the larger the occlusal contact area obtained. The differences were statistically significant. In all cases, the occlusal registrations obtained with the thinnest articulating paper were contained within the area marked on the thickest articulating paper. The results suggested that the use of thin articulating papers (12-μm or 40-μm) can avoid unnecessary grinding of veneering material or teeth during occlusal adjustment.

  7. ACUTE RETINAL ARTERIAL OCCLUSIVE DISORDERS

    PubMed Central

    Hayreh, Sohan Singh

    2011-01-01

    The initial section deals with basic sciences; among the various topics briefly discussed are the anatomical features of ophthalmic, central retinal and cilioretinal arteries which may play a role in acute retinal arterial ischemic disorders. Crucial information required in the management of central retinal artery occlusion (CRAO) is the length of time the retina can survive following that. An experimental study shows that CRAO for 97 minutes produces no detectable permanent retinal damage but there is a progressive ischemic damage thereafter, and by 4 hours the retina has suffered irreversible damage. In the clinical section, I discuss at length various controversies on acute retinal arterial ischemic disorders. Classification of acute retinal arterial ischemic disorders These are of 4 types: CRAO, branch retinal artery occlusion (BRAO), cotton wools spots and amaurosis fugax. Both CRAO and BRAO further comprise multiple clinical entities. Contrary to the universal belief, pathogenetically, clinically and for management, CRAO is not one clinical entity but 4 distinct clinical entities – non-arteritic CRAO, non-arteritic CRAO with cilioretinal artery sparing, arteritic CRAO associated with giant cell arteritis (GCA) and transient non-arteritic CRAO. Similarly, BRAO comprises permanent BRAO, transient BRAO and cilioretinal artery occlusion (CLRAO), and the latter further consists of 3 distinct clinical entities - non-arteritic CLRAO alone, non-arteritic CLRAO associated with central retinal vein occlusion and arteritic CLRAO associated with GCA. Understanding these classifications is essential to comprehend fully various aspects of these disorders. Central retinal artery occlusion The pathogeneses, clinical features and management of the various types of CRAO are discussed in detail. Contrary to the prevalent belief, spontaneous improvement in both visual acuity and visual fields does occur, mainly during the first 7 days. The incidence of spontaneous visual

  8. Trial occlusion to assess the risk of persistent pulmonary arterial hypertension after closure of a large patent ductus arteriosus in adolescents and adults with elevated pulmonary artery pressure.

    PubMed

    Zhang, Duan-Zhen; Zhu, Xian-Yang; Lv, Bei; Cui, Chun-Sheng; Han, Xiu-Min; Sheng, Xiao-Tang; Wang, Qi-Guang; Zhang, Po

    2014-08-01

    No method is available to predict whether patients with patent ductus arteriosus (PDA) and severe pulmonary arterial hypertension (PAH) will show persistent postprocedural PAH (PP-PAH) after PDA closure. This study evaluated the usefulness of trial occlusion for predicting PP-PAH after transcatheter PDA closure in patients with severe PAH. Trial occlusion was performed in 137 patients (age ≥12 years) with PDA and severe PAH. All patients undergoing trial occlusion had a mean pulmonary artery pressure ≥45 mm Hg, pulmonary:systemic flow (Qp/Qs) ratio >1.5, and pulmonary:systemic resistance (Rp/Rs) ratio <0.7. A total of 135 patients (98%) showing stable hemodynamics during occlusion trial underwent successful device closure. Linear correlation analysis revealed weak or moderate relationships between the baseline and post-trial pulmonary artery pressures and pulmonary:systemic pressure (Pp/Ps) ratios. Patients were followed up for 1 to 10 years (median: 5 years). PP-PAH (systolic pulmonary artery pressure >50 mm Hg by Doppler echocardiography) was detected in 17 patients (13%), who displayed no significant differences in sex and age compared with patients without PP-PAH. According to discriminant analysis, the strongest discriminators between patients with and without PP-PAH were the baseline left ventricular end-diastolic volume and the baseline and post-trial systolic Pp/Ps ratios. In particular, a post-trial systolic Pp/Ps ratio >0.5 correctly classified 100% of the PP-PAH and non-PAH patients. Trial occlusion is a feasible method to predict PP-PAH in patients with PDA and severe PAH. A post-trial systolic Pp/Ps ratio >0.5 indicates a high risk of PP-PAH occurrence after device closure. © 2014 American Heart Association, Inc.

  9. Pressure monitoring predicts pulmonary vein occlusion in cryoballoon ablation.

    PubMed

    Sunaga, Akihiro; Masuda, Masaharu; Asai, Mitsutoshi; Iida, Osamu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Matsuda, Yasuhiro; Okuno, Syota; Mano, Toshiaki

    2018-04-10

    Pulmonary venography is routinely used to confirm pulmonary vein (PV) occlusion during cryoballoon ablation. However, this technique is significantly limited by the risks associated with contrast media, such as renal injury and contrast allergy. We hypothesized that PV occlusion can be predicted by elevation of the balloon catheter tip pressure, avoiding the need for contrast media. Forty-eight consecutive patients with paroxysmal atrial fibrillation who underwent PV isolation with the cryoballoon technique were enrolled. The balloon catheter tip pressure was measured in each PV before and after balloon inflation. We analyzed 200 applications of cryoballoon ablation in 185 PVs (excluding 3 common PVs and 1 extremely small right inferior PV) of 48 patients (age, 70 ± 11 years; male, n = 28; mean left atrial diameter, 38 ± 6 mm). Compared with patients with unsuccessful occlusion, patients with successful occlusion demonstrated a larger change in pressure after balloon inflation (6 ± 8 vs. 2 ± 4 mmHg, P < 0.001), a lower minimum temperature (- 49 ± 6 vs. - 40 ± 8 °C, P < 0.001), and a higher PV isolation rate (97 vs. 64%, P < 0.001). The best cutoff value of a change in pressure for predicting PV occlusion was 4.5 mmHg, with a sensitivity of 67%, specificity of 83%, and predictive accuracy of 72%. Pressure monitoring is helpful to confirm PV occlusion during cryoballoon ablation.

  10. Occlusal factors are not related to self-reported bruxism.

    PubMed

    Manfredini, Daniele; Visscher, Corine M; Guarda-Nardini, Luca; Lobbezoo, Frank

    2012-01-01

    To estimate the contribution of various occlusal features of the natural dentition that may identify self-reported bruxers compared to nonbruxers. Two age- and sex-matched groups of self-reported bruxers (n = 67) and self-reported nonbruxers (n = 75) took part in the study. For each patient, the following occlusal features were clinically assessed: retruded contact position (RCP) to intercuspal contact position (ICP) slide length (< 2 mm was considered normal), vertical overlap (< 0 mm was considered an anterior open bite; > 4 mm, a deep bite), horizontal overlap (> 4 mm was considered a large horizontal overlap), incisor dental midline discrepancy (< 2 mm was considered normal), and the presence of a unilateral posterior crossbite, mediotrusive interferences, and laterotrusive interferences. A multiple logistic regression model was used to identify the significant associations between the assessed occlusal features (independent variables) and self-reported bruxism (dependent variable). Accuracy values to predict self-reported bruxism were unacceptable for all occlusal variables. The only variable remaining in the final regression model was laterotrusive interferences (P = .030). The percentage of explained variance for bruxism by the final multiple regression model was 4.6%. This model including only one occlusal factor showed low positive (58.1%) and negative predictive values (59.7%), thus showing a poor accuracy to predict the presence of self-reported bruxism (59.2%). This investigation suggested that the contribution of occlusion to the differentiation between bruxers and nonbruxers is negligible. This finding supports theories that advocate a much diminished role for peripheral anatomical-structural factors in the pathogenesis of bruxism.

  11. No wire? No problem: Resuscitative endovascular balloon occlusion of the aorta (REBOA) can be performed effectively and more rapidly with a wire-free device.

    PubMed

    Romagnoli, Anna Noel; Teeter, William; Wasicek, Philip; Gamble, William Bryan; Hu, Fu Peter M; Stein, Deborah; Scalea, Thomas; Brenner, Megan

    2018-06-12

    A wire-free device is available for REBOA providing aortic occlusion (AO) without lengthy platform guide-wires and large sheaths. This was a retrospective, single-institution review of patients who received REBOA from May 2014-September 2017. Timing of procedural steps was measured in seconds (s) using time-stamped videography. 74 patients received REBOA; 29 with a platform guidewire, 12F sheath, and balloon catheter (W group), and 45 with a 7F sheath and wire-free device (WF group). Mean age (p=0.22) and ISS (p=0.80) were similar between groups. 59 patients received REBOA at Zone 1; 15 patients at Zone 3. There was no difference in median [IQR] time to common femoral artery (CFA) access between the WF (194[98,313]s) and W (193[126,280]s) groups (p=0.96). Both median time to AO after CFA access (WF:158[109,264]s vs. W:307[222,390]s, p<0.001) and median total procedural time (WF:366[263,596]s vs. W:511[441,597]s; p=0.012) were significantly shorter with the wire-free system. The rates of percutaneous versus open CFA access was not different between groups (p=0.48). Both groups had a similar physiologic response to AO as measured by pre- and post-AO SBP (p=0.86). Overall mortality rate was 74%; 90% in the W group, and 64% in the WF group (p = 0.027). The procedure-related complication rate was not significantly different between groups with regard to compartment syndrome (W:3% vs WF:4%, p=1.0), access-related complications (W:0 vs WF:6%, p=0.28) or systemic complication (W:0 vs WF:9%, p=0.15). Once CFA access is obtained, AO with a smaller wire-free device reduces procedural time by approximately 50%. When perfusion to proximal organs is essential, the seconds saved to achieve AO may contribute to improved mortality. Time to obtain CFA access is not dependent on introducer sheath size. Therapeutic, Level V.

  12. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  13. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  14. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  15. Amplatzer vascular plug for rapid vessel occlusion in interventional neuroradiology

    PubMed Central

    Banfield, Jillian C

    2016-01-01

    The purpose of this paper is to report different uses of endovascular Amplatzer vascular plug (AVP) treatment for rapid vessel occlusion in the field of interventional neuroradiology. We retrospectively reviewed our interventional neuroradiology database from November 2010 to July 2015 and found nine patients who were treated with endovascular AVP. AVP was used for rapid vessel occlusion of common carotid artery (1 patient), internal carotid artery (5 patients), vertebral artery (2 patients), and internal jugular vein (1 patient). A median of three AVPs were used with almost immediate occlusion and no thromboembolic complications. Use of AVP is feasible, safe, rapid, and potentially cost-effective method for rapid occlusion of larger size vessels in the head and neck region for different indications. PMID:26515699

  16. Research trend in thermally stimulated current method for development of materials and devices in Japan

    NASA Astrophysics Data System (ADS)

    Iwamoto, Mitsumasa; Taguchi, Dai

    2018-03-01

    Thermally stimulated current (TSC) measurement is widely used in a variety of research fields, i.e., physics, electronics, electrical engineering, chemistry, ceramics, and biology. TSC is short-circuit current that flows owing to the displacement of charges in samples during heating. TSC measurement is very simple, but TSC curves give very important information on charge behaviors. In the 1970s, TSC measurement contributed greatly to the development of electrical insulation engineering, semiconductor device technology, and so forth. Accordingly, the TSC experimental technique and its analytical method advanced. Over the past decades, many new molecules and advanced functional materials have been discovered and developed. Along with this, TSC measurement has attracted much attention in industries and academic laboratories as a way of characterizing newly discovered materials and devices. In this review, we report the latest research trend in the TSC method for the development of materials and devices in Japan.

  17. History of materials used for recording static and dynamic occlusal contact marks: a literature review

    PubMed Central

    Rahul, G R.; Poduval, Soorya T.; Shetty, Karunakar; Gupta, Bhawna; Rajora, Varun

    2013-01-01

    In the discipline of prosthetic dentistry it is important not only to examine the occlusion, but to be able to record, store, and transfer the information. Over the years many occlusion testing materials have been used. It has been suggested the clinical recording and transfer of information using waxes and other occlusion recording materials have disadvantages relating to inaccuracy and problems of manipulation. Therefore, there has been introduction of many new systems for recording occlusion contacts to overcome such problems. The correct physiological recovery of occlusion posses as much a challenge as ever for every dentist and technician. Even the smallest high spots measuring just a few microns can cause dysfunctions like temporo-mandibular pain. Occlusal proportions are being constantly changed with every procedure. Therefore, an understanding of the synergy of the teeth in static and dynamic occlusion forms the basis of good dentistry. The purpose of this review article is to give and overview of the various materials and methods that have been used to record occlusal contact marks. Key words:Occlusal contact marks, Occlusion indicators, Occlusion test materials, Occlusion recording materials. PMID:24455051

  18. Influence of occlusal loading on peri-implant clinical parameters. A pilot study

    PubMed Central

    Pellicer-Chover, Hilario; Viña-Almunia, José; Romero-Millán, Javier; Peñarrocha-Oltra, David; Peñarrocha-Diago, María

    2014-01-01

    Objectives: To investigate the relation between occlusal loading and peri-implant clinical parameters (probing depth, bleeding on probing, gingival retraction, width of keratinized mucosa, and crevicular fluid volume) in patients with implant-supported complete fixed prostheses in both arches. Material and Methods: This clinical study took place at the University of Valencia (Spain) dental clinic. It included patients attending the clinic for regular check-ups during at least 12 months after rehabilitation of both arches with implant-supported complete fixed ceramo-metallic prostheses. One study implant and one control implant were established for each patient using the T-Scan®III computerized system (Tesco, South Boston, USA). The maxillary implant closest to the point of maximum occlusal loading was taken as the study implant and the farthest (with least loading) as the control. Occlusal forces were registered with the T-Scan® III and then occlusal adjustment was performed to distribute occlusal forces correctly. Peri-implant clinical parameters were analyzed in both implants before and two and twelve months after occlusal adjustment. Results: Before occlusal adjustment, study group implants presented a higher mean volume of crevicular fluid (51.3±7.4 UP) than the control group (25.8±5.5 UP), with statistically significant difference. Two months after occlusal adjustment, there were no significant differences between groups (24.6±3.8 UP and 26±4.5 UP respectively) (p=0.977). After twelve months, no significant differences were found between groups (24.4±11.1 UP and 22.5±8.9 UP respectively) (p=0.323). For the other clinical parameters, no significant differences were identified between study and control implants at any of the study times (p>0.05). Conclusions: Study group implants receiving higher occlusal loading presented significantly higher volumes of crevicular fluid than control implants. Crevicular fluid volumes were similar in both groups two and

  19. The muscle engram: the reflex that limits conventional occlusal treatment.

    PubMed

    Lerman, Martin D

    2011-10-01

    The engram (the masticatory "muscle memory") is shown to be a conditionable reflex whose muscle conditioning lasts less than two minutes, far shorter than previously thought. This reflex, reinforced and stored in the masticatory muscles at every swallow, adjusts masticatory muscle activity to guide the lower arch unerringly into its ICP. These muscle adjustments compensate for the continually changing intemal and external factors that affect the mandible's entry into the ICP. A simple quick experiment described in this article isolates the engram, enabling the reader to see its action clearly for the first time. It is urged that every reader perform this experiment. This experiment shows how the engram, by hiding the masticatory muscles' reaction (the hit-and-slide), limits the success of the therapist in achieving occlusion-muscle compatibility. This finding has major clinical implications. It means that, as regards the muscle aspect of treating occlusion, the dentist treating occlusion conventionally is working blind, a situation the neuromuscular school of occlusal thought seeks to correct. The controversy over occlusion continues.

  20. Effects of noninvasive facial nerve stimulation in the dog middle cerebral artery occlusion model of ischemic stroke.

    PubMed

    Borsody, Mark K; Yamada, Chisa; Bielawski, Dawn; Heaton, Tamara; Castro Prado, Fernando; Garcia, Andrea; Azpiroz, Joaquín; Sacristan, Emilio

    2014-04-01

    Facial nerve stimulation has been proposed as a new treatment of ischemic stroke because autonomic components of the nerve dilate cerebral arteries and increase cerebral blood flow when activated. A noninvasive facial nerve stimulator device based on pulsed magnetic stimulation was tested in a dog middle cerebral artery occlusion model. We used an ischemic stroke dog model involving injection of autologous blood clot into the internal carotid artery that reliably embolizes to the middle cerebral artery. Thirty minutes after middle cerebral artery occlusion, the geniculate ganglion region of the facial nerve was stimulated for 5 minutes. Brain perfusion was measured using gadolinium-enhanced contrast MRI, and ATP and total phosphate levels were measured using 31P spectroscopy. Separately, a dog model of brain hemorrhage involving puncture of the intracranial internal carotid artery served as an initial examination of facial nerve stimulation safety. Facial nerve stimulation caused a significant improvement in perfusion in the hemisphere affected by ischemic stroke and a reduction in ischemic core volume in comparison to sham stimulation control. The ATP/total phosphate ratio showed a large decrease poststroke in the control group versus a normal level in the stimulation group. The same stimulation administered to dogs with brain hemorrhage did not cause hematoma enlargement. These results support the development and evaluation of a noninvasive facial nerve stimulator device as a treatment of ischemic stroke.

  1. Percutaneous Occlusion of the Left Atrial Appendage with the Watchman Device in an Active Duty Sailor with Atrial Fibrillation and Recurrent Thromboembolism Despite Appropriate Use of Oral Anticoagulation.

    PubMed

    Cox, Justin M; Choi, Anthony J; Oakley, Luke S; Francisco, Gregory M; Nayak, Keshav R

    2018-05-23

    Atrial fibrillation is the most common significant cardiac arrhythmia and is associated with a five-fold increased risk of stroke from thromboembolism. Over 94% of these emboli arise from the left atrial appendage. Systemic embolic phenomena are rare, accounting for less than 1 out of 10 of all embolic events, but have a similar prevention strategy. Anticoagulation significantly reduces the risk of these events, and thus forms the cornerstone of therapy for most patients with atrial fibrillation. Left atrial appendage occlusion with the Watchman device is a recently approved alternative for stroke prevention in selected patients. We present a case of an active duty U.S. Navy sailor at low risk for thromboembolism who nonetheless suffered recurrent thromboembolic events despite appropriate anticoagulation, and thus underwent Watchman implantation. The therapy in this case will ideally provide a lifetime of protection from recurrent systemic embolization while allowing the patient to continue his active duty military career without restriction due to oral anticoagulation.

  2. Side effects of stabilization occlusal splints: a report of three cases and literature review.

    PubMed

    Magdaleno, Fernando; Ginestal, Eduardo

    2010-04-01

    Stabilization splints are frequently used for the treatment of temporomandibular disorders (TMD) and bruxism, despite the fact that little is known about their mechanism of action or the precise conditions under which they can be recommended. Moreover, information about their possible adverse effects, which in the majority of cases include occlusal modifications of little clinical relevance, is scarce. On occasions, these splints can provoke severe occlusal alterations and other complications, which are rarely alluded to in the literature. Here presented in this paper are three case reports in which part-time stabilization splints led to irreversible occlusal alterations and a discussion of the relevant clinical implications. Such splints are reported to negatively affect the condyle-disk relation in patients who exhibit disk displacement with reduction and to modify breathing features in patients with obstructive sleep apnea, although further studies are required to unequivocally demonstrate these findings. Finally, the splint seems to modify peripheral information at the level of the Central Nervous System, leading to modifications in corporal postural tone. The clinical repercussions of such alterations are currently poorly understood. It is our hope that future research will throw fresh light on these important topics.

  3. A study of parallelism of the occlusal plane and ala-tragus line.

    PubMed

    Sadr, Katayoun; Sadr, Makan

    2009-01-01

    Orientation of the occlusal plane is one of the most important clinical procedures in prostho-dontic rehabilitation of edentulous patients. The aim of this study was to define the best posterior reference point of ala-tragus line for orientation of occlusal plane for complete denture fabrication. Fifty-three dental students (27 females and 26 males) with complete natural dentition and Angel's Class I occlusal relationship were selected. The subjects were photographed in natural head position while clenching on a Fox plane. After tracing the photographs, the angles between the following lines were measured: the occlusal plane (Fox plane) and the superior border of ala-tragus, the occlusal plane (Fox plane) and the middle of ala-tragus as well as the occlusal plane (Fox plane) and the inferior border of ala-tragus. Descriptive statistics, one sample t-test and independent t-test were used. P value less than 0.05 was considered significant. There was no parallelism between the occlusal plane and ala-tragus line with three different posterior ends and one sample t-test showed that the angles between them were significantly different from zero (p<0.05). However, the supe-rior border of ala-tragus line had the lowest mean angle, 1.80° (3.12) and was almost parallel to the occlusal plane. The superior border of the tragus is suggested as the posterior reference for ala-tragus line.

  4. Posterior Teeth Occlusion Associated with Cognitive Function in Nursing Home Older Residents: A Cross-Sectional Observational Study

    PubMed Central

    Takeuchi, Kenji; Izumi, Maya; Furuta, Michiko; Takeshita, Toru; Shibata, Yukie; Kageyama, Shinya; Ganaha, Seijun; Yamashita, Yoshihisa

    2015-01-01

    Early detection and subsequent reduction of modifiable risk factors for cognitive decline is important for extending healthy life expectancy in the currently aging society. Although a recent increase in studies on the state or number of the teeth and cognitive function, few studies have focused on the association between posterior teeth occlusion necessary to maintain chewing function and cognitive function among older adults. This study examined the association between posterior teeth occlusion and cognitive function in nursing home older residents. In this cross-sectional study, 279 residents aged ≥60 years from eight nursing homes in Aso City, Japan participated in cognitive function and dental status assessments and completed a comprehensive questionnaire survey in 2014. Cognitive function was measured using a Mini-Mental State Examination (MMSE). Posterior teeth occlusion was assessed using a total number of functional tooth units (total-FTUs), depending on the number and location of the remaining natural and artificial teeth on implant-supported, fixed, and removable prostheses. Linear regression models were used to assess univariate and multivariate associations between total-FTUs and MMSE scores. Models were sequentially adjusted for demographic characteristics, number of natural teeth, socioeconomic status, health behaviors, comorbidities, physical function, and nutritional status. Among the 200 residents included in our analysis, mean MMSE scores and total-FTUs were 11.0 ± 8.6 and 9.3 ± 4.6, respectively. Higher total-FTUs were significantly associated with higher MMSE scores after adjustment for demographics and teeth number (B = 0.48, 95% confidence interval [CI] = 0.22–0.74). The association remained significant even after adjustment for all covariates (B = 0.25, 95% CI = 0.01–0.49). The current findings demonstrated that loss of posterior teeth occlusion was independently associated with cognitive decline in nursing home older residents in

  5. Novel Evidence-Based Classification of Cavernous Venous Occlusive Disease.

    PubMed

    Pathak, Ram A; Rawal, Bhupendra; Li, Zhuo; Broderick, Gregory A

    2016-10-01

    The primary aim of our study was to determine whether an evidence-based rationale could categorize cavernous venous occlusive disease into mild, moderate and severe erectile dysfunction. A total of 863 patients underwent color duplex Doppler ultrasound from January 2010 to June 2013 performed by a single urologist. We identified a cohort of 75 patients (8.7%) with a diagnosis of cavernous venous occlusive disease based on a unilateral resistive index less than 0.9, and right and left peak systolic velocity 35 cm per second or less after visual sexual stimulation. At a median followup of 13 months patients were evaluated for treatment efficacy. A total of 75 patients with a median age of 60 years (range 19 to 83) and a mean body mass index of 26.3 kg/m(2) (range 19.0 to 39.3) satisfied the criteria of cavernous venous occlusive disease. When substratified into tertiles, resistive index cutoffs were obtained, including mild cavernous venous occlusive disease-81.6 to 94.0, moderate disease-72.6 to 81.5 and severe disease-59.5 to 72.5. Using these 3 groups the phosphodiesterase type 5-inhibitor failure rate (p = 0.017) and SHIM (Sexual Health Inventory for Men) score categories (1 to 10 vs 11 to 20, p = 0.030) were statistically significantly different for mild, moderate and severe cavernous venous occlusive disease. Treatment satisfaction was also statistically significantly different. Penile prosthetic placement was a more common outcome among patients with erectile dysfunction and more severe cavernous venous occlusive disease. Our retrospective analysis supports a correlation between the phosphodiesterase type 5 inhibitor failure rate, SHIM score and the rate of surgical intervention using resistive index values. Our data further suggest that an evidence-based classification of cavernous venous occlusive disease by color Doppler ultrasound is possible and can triage patients to penile prosthetic placement. Copyright © 2016 American Urological Association

  6. Radio-frequency-assisted current startup in the fusion engineering device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borowski, S. K.; Peng, Yueng Kay Martin; Kammash, T.

    1984-01-01

    Auxiliary radio-frequency (RF) heating of electrons before and during the current rise phase of a large tokamak, such as the Fusion Engineering Device (FED) (R{sub 0} = 4.8 m, a = 1.3 m, sigma = 1.6, B(R{sub 0}) = 3.62 T), is examined as a means of reducing both the initiation loop voltage and resistive flux expenditure during startup. Prior to current initiation, 1 to 2 MW of electron cyclotron resonance heating power at about90 GHz is used to create a small volume of high conductivity plasma (T {sub e} approx. = 100 eV, n {sub e} approx. = 10{supmore » 19} m{sup -3}) near the upper hybrid resonance (UHR) region. This plasma conditioning, referred to as preheating, permits a small radius (a{sub 0} approx. = 0.2 to 0.4 m) current channel to be established with a relatively low initial loop voltage (less than or equal to 25 V as opposed to about 100 V without rf assist). During the subsequent plasma expansion and current rise phase, a combination of rf heating (up to 5 MW) and linear current ramping leads to a substantial savings in voltseconds by (a) minimizing the resistive flux consumption and (b) producing broad current density profiles. (With such broad profiles, the internal flux requirements are maintained at or near the flat profile limit.)« less

  7. Radio-frequency-assisted current startup in the Fusion Engineering Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borowski, S.K.; Kammash, T.; Martin Peng, Y.K.

    1984-07-01

    Auxiliary radio-frequency (RF) heating of electrons before and during the current rise phase of a large tokamak, such as the Fusion Engineering Device (FED) (R/sub 0/ = 4.8 m, a = 1.3 m, sigma = 1.6, B(R/sub 0/) = 3.62 T), is examined as a means of reducing both the initiation loop voltage and resistive flux expenditure during startup. Prior to current initiation, 1 to 2 MW of electron cyclotron resonance heating power at about90 GHz is used to create a small volume of high conductivity plasma (T /sub e/ approx. = 100 eV, n /sub e/ approx. = 10/supmore » 19/ m/sup -3/) near the upper hybrid resonance (UHR) region. This plasma conditioning, referred to as preheating, permits a small radius (a/sub 0/ approx. = 0.2 to 0.4 m) current channel to be established with a relatively low initial loop voltage (less than or equal to 25 V as opposed to about 100 V without rf assist). During the subsequent plasma expansion and current rise phase, a combination of rf heating (up to 5 MW) and linear current ramping leads to a substantial savings in voltseconds by (a) minimizing the resistive flux consumption and (b) producing broad current density profiles. (With such broad profiles, the internal flux requirements are maintained at or near the flat profile limit.)« less

  8. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    PubMed

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  9. Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients.

    PubMed

    Thanathornwong, Bhornsawan; Suebnukarn, Siriwan

    2017-10-01

    The aim of this study was to develop a decision support model for the prediction of occlusal force from the size and color of articulating paper markings in bruxism patients. We used the information from the datasets of 30 bruxism patients in which digital measurements of the size and color of articulating paper markings (12-µm Hanel; Coltene/Whaledent GmbH, Langenau, Germany) on canine protected hard stabilization splints were measured in pixels (P) and in red (R), green (G), and blue (B) values using Adobe Photoshop software (Adobe Systems, San Jose, CA, USA). The occlusal force (F) was measured using T-Scan III (Tekscan Inc., South Boston, MA, USA). The multiple regression equation was applied to predict F from the P and RGB. Model evaluation was performed using the datasets from 10 new patients. The patient's occlusal force measured by T-Scan III was used as a 'gold standard' to compare with the occlusal force predicted by the multiple regression model. The results demonstrate that the correlation between the occlusal force and the pixels and RGB of the articulating paper markings was positive (F = 1.62×P + 0.07×R -0.08×G + 0.08×B + 4.74; R 2 = 0.34). There was a high degree of agreement between the occlusal force of the patient measured using T-Scan III and the occlusal force predicted by the model (kappa value = 0.82). The results obtained demonstrate that the multiple regression model can predict the occlusal force using the digital values for the size and color of the articulating paper markings in bruxism patients.

  10. Clinical Decision Support Model to Predict Occlusal Force in Bruxism Patients

    PubMed Central

    Thanathornwong, Bhornsawan

    2017-01-01

    Objectives The aim of this study was to develop a decision support model for the prediction of occlusal force from the size and color of articulating paper markings in bruxism patients. Methods We used the information from the datasets of 30 bruxism patients in which digital measurements of the size and color of articulating paper markings (12-µm Hanel; Coltene/Whaledent GmbH, Langenau, Germany) on canine protected hard stabilization splints were measured in pixels (P) and in red (R), green (G), and blue (B) values using Adobe Photoshop software (Adobe Systems, San Jose, CA, USA). The occlusal force (F) was measured using T-Scan III (Tekscan Inc., South Boston, MA, USA). The multiple regression equation was applied to predict F from the P and RGB. Model evaluation was performed using the datasets from 10 new patients. The patient's occlusal force measured by T-Scan III was used as a ‘gold standard’ to compare with the occlusal force predicted by the multiple regression model. Results The results demonstrate that the correlation between the occlusal force and the pixels and RGB of the articulating paper markings was positive (F = 1.62×P + 0.07×R –0.08×G + 0.08×B + 4.74; R2 = 0.34). There was a high degree of agreement between the occlusal force of the patient measured using T-Scan III and the occlusal force predicted by the model (kappa value = 0.82). Conclusions The results obtained demonstrate that the multiple regression model can predict the occlusal force using the digital values for the size and color of the articulating paper markings in bruxism patients. PMID:29181234

  11. Effectiveness of various toothpastes on dentine tubule occlusion.

    PubMed

    Arnold, W H; Prange, M; Naumova, E A

    2015-04-01

    Dentine hypersensitivity is an increasing problem in dentistry. Several products are available that claim to occlude open dentine tubules and to reduce dentine hypersensitivity. The aim of this study was to investigate the effectiveness of several different products on dentine tubule occlusion using qualitative and quantitative methods. Dentine discs were prepared from extracted human premolars and molars. The dentine discs were brushed with 6 different experimental toothpastes, 1 positive control toothpaste and 1 negative control without toothpaste; the brushing simulated a total brushing time of 1 year. Half of the discs were etched with lemon juice after toothpaste application. Standardized scanning electron microphotographs were taken and converted into binary black and white images. The black pixels, which represented the open dentine tubules, were counted and statistically evaluated. Then, half of the dentine discs were broken, and the occlusion of the dentine tubules was investigated using energy dispersive X-ray spectroscopy (EDS). The number of open dentine tubules decreased significantly after brushing with 5 of the 6 tested toothpastes. A significant effect was observed after acid erosion for 3 of the 6 tested toothpastes. EDS revealed partly closed dentine tubules after brushing with 3 toothpastes; however, no partly closed dentine tubules were observed after acid erosion. Some toothpastes are capable of partial dentine tubule occlusion. This occlusion is unstable and can be removed with acid erosion. Desensitizing toothpastes are the most common products that are used against dentine hypersensitivity, and these toothpastes affect dentine tubule occlusion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Laparoscopic uterine artery occlusion for symptomatic leiomyomas.

    PubMed

    Lichtinger, Moises; Hallson, Laurey; Calvo, Patricia; Adeboyejo, Ghea

    2002-05-01

    To describe a laparoscopic technique that safely occludes both uterine arteries, overcoming an altered surgical field resulting from scarring and/or uterine leiomyomatous growth. Prospective analysis (Canadian Task Force classification II-2). Nonprofit community hospital. Eight women with leiomyomas with abnormal uterine bleeding, pelvic pain or pressure, and/or anemia. Bilateral laparoscopic retroperitoneal uterine artery occlusion. Occlusion at the initial track of the uterine artery was performed by laparoscopic coated ligature in six patients. In two obese patients with deep retroperitoneal space, vascular clips were placed endoscopically using the same dissecting technique. All patients were discharged within 20 hours after the procedure. All five women with abnormal bleeding reported satisfactory decrease; none reported amenorrhea. Of eight with preoperative pain or pressure, seven reported complete disappearance and one significant relief. All three patients with anemia had normal red cell counts after 1 month. Laparoscopic uterine artery occlusion using a lateral retroperitoneal technique is safe and effective in women with pelvic scarring and altered pelvic anatomy.

  13. Reconstruction-Based Digital Dental Occlusion of the Partially Edentulous Dentition.

    PubMed

    Zhang, Jian; Xia, James J; Li, Jianfu; Zhou, Xiaobo

    2017-01-01

    Partially edentulous dentition presents a challenging problem for the surgical planning of digital dental occlusion in the field of craniomaxillofacial surgery because of the incorrect maxillomandibular distance caused by missing teeth. We propose an innovative approach called Dental Reconstruction with Symmetrical Teeth (DRST) to achieve accurate dental occlusion for the partially edentulous cases. In this DRST approach, the rigid transformation between two symmetrical teeth existing on the left and right dental model is estimated through probabilistic point registration by matching the two shapes. With the estimated transformation, the partially edentulous space can be virtually filled with the teeth in its symmetrical position. Dental alignment is performed by digital dental occlusion reestablishment algorithm with the reconstructed complete dental model. Satisfactory reconstruction and occlusion results are demonstrated with the synthetic and real partially edentulous models.

  14. Reconstruction-based Digital Dental Occlusion of the Partially Edentulous Dentition

    PubMed Central

    Zhang, Jian; Xia, James J.; Li, Jianfu; Zhou, Xiaobo

    2016-01-01

    Partially edentulous dentition presents a challenging problem for the surgical planning of digital dental occlusion in the field of craniomaxillofacial surgery because of the incorrect maxillomandibular distance caused by missing teeth. We propose an innovative approach called Dental Reconstruction with Symmetrical Teeth (DRST) to achieve accurate dental occlusion for the partially edentulous cases. In this DRST approach, the rigid transformation between two symmetrical teeth existing on the left and right dental model is estimated through probabilistic point registration by matching the two shapes. With the estimated transformation, the partially edentulous space can be virtually filled with the teeth in its symmetrical position. Dental alignment is performed by digital dental occlusion reestablishment algorithm with the reconstructed complete dental model. Satisfactory reconstruction and occlusion results are demonstrated with the synthetic and real partially edentulous models. PMID:26584502

  15. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery.

    PubMed

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro

    2017-06-01

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. • Hepatic artery occlusion causes haemodynamic changes in hepatocellular carcinoma and liver. • Segmental occlusion decreased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Subsegmental occlusion increased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Hepatic artery occlusion decreased enhancement volume of hepatocellular carcinoma and liver. • Hepatic artery occlusion causes perfusion defects in hepatocellular carcinoma.

  16. Endovascular management of inferior vena cava filter thrombotic occlusion.

    PubMed

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  17. Choice of biomaterials—Do soft occlusal splints influence jaw-muscle activity during sleep? A preliminary report

    NASA Astrophysics Data System (ADS)

    Arima, Taro; Takeuchi, Tamiyo; Tomonaga, Akio; Yachida, Wataru; Ohata, Noboru; Svensson, Peter

    2012-12-01

    AimThe choice of biomaterials for occlusal splints may significantly influence biological outcome. In dentistry, hard acrylic occlusal splints (OS) have been shown to have a temporary and inhibitory effect on jaw-muscle activity, such as tooth clenching and grinding during sleep, i.e., sleep bruxism (SB). Traditionally, this inhibitory effect has been explained by changes in the intraoral condition rather than the specific effects of changes in occlusion. The aim of this preliminary study was to investigate the effect of another type of occlusal surface, such as a soft-material OS in addition to a hard-type OS in terms of changes in jaw-muscle activity during sleep. Materials and methodsSeven healthy subjects (mean ± SD, six men and one woman: 28.9 ± 2.7 year old), participated in this study. A soft-material OS (ethylene vinyl acetate copolymer) was fabricated for each subject and the subjects used the OS for five continuous nights. The EMG activity during sleep was compared to baseline (no OS). Furthermore, the EMG activity during the use of a hard-type OS (Michigan-type OS, acrylic resin), and hard-type OS combined with contingent electrical stimulation (CES) was compared to baseline values. Each session was separated by at least two weeks (washout). Jaw-muscle activity during sleep was recorded with single-channel ambulatory devices (GrindCare, MedoTech, Herlev, Denmark) in all sessions for five nights. ResultsJaw-muscle activity during sleep was 46.6 ± 29.8 EMG events/hour at baseline and significantly decreased during the hard-type OS (17.4 ± 10.5, P = 0.007) and the hard-type OS + CES (10.8 ± 7.1, P = 0.002), but not soft-material OS (36.3 ± 24.5, P = 0.055). Interestingly, the soft-material OS (coefficient of variance = 98.6 ± 35.3%) was associated with greater night-to-night variations than baseline (39.0 ± 11.8%) and the hard-type OS + CES (53.3 ± 13.7%, P < 0.013). ConclusionThe present pilot study in small sample showed that a soft

  18. The mechanisms of intrarenal hemodynamic changes following acute arterial occlusion.

    DOT National Transportation Integrated Search

    1963-10-01

    The hemodynamic response of the kidney to acute arterial occlusion is poorly understood. The purpose of the present study was to determine intrarenal hemodynamic changes in intact and isolated kidneys following arterial occlusion. : The relative role...

  19. [A Project to Reduce the Occlusion Rate in Hemodialysis Arteriovenous Access].

    PubMed

    Huang, Jia-Ling; Jang, Jeng-Fong; Lee, Kun-Feng; Shie, Yu-Ting; Jin, Mei-Hua

    2015-06-01

    Vascular occlusions in patients frequently necessitate that duty nurses work overtime to manage related vascular problems. For patients, vascular occlusions require invasive treatments that are painful, take time to heal, and increase anxiety. Furthermore, vascular occlusions seriously influence the effectiveness of hemodialysis. This project worked to reduce the rates of occlusion from 18.6% to < 15% for hemodialysis arteriovenous grafts (AVGs) and from 5.2% to < 2.6% for arteriovenous fistulas (AVFs). This project was conducted between September 1st, 2012 and July 31th, 2013. Our approach used a retrospective study, literature review, meeting discussions, and data compilation. The four main problems identified as associated with occlusion were: (1) low blood pressure during hemodialysis; (2) successive fistula puncture sites were located too close to one another; (3) abnormal blood flow; and (4) poor moisture control. Our solutions included: 1) adjusting and creating forms; 2) adjusting related nursing procedures; and 3) organizing a related lecture for our department. The occlusion rates of AVG and AVF decreased from 18.6% to 7.4% and 5.2% to 0.9%, respectively. We significantly reduced AVG and AVF occlusion rates by using simple methods such as using a tourniquet ruler, designing big-print, illustrated patient instruction sheets on preventing low blood pressure, creating a simplified fistula puncture site series chart, creating a moisture control card, and scheduling follow-up visits for patients with abnormal blood flow at the OPD. This project provides a reference for other hemodialysis departments.

  20. Effect of occlusal trauma on healing of periapical pathoses: report of two cases.

    PubMed

    Harn, W M; Chen, M C; Chen, Y H; Liu, J W; Chung, C H

    2001-10-01

    To present two clinical cases and demonstrate that occlusal trauma may affect healing of periapical pathoses. Two teeth with periradicular disease did not respond successfully to conventional root canal treatment or endodontic surgery. Occlusal adjustment was finally performed on both cases. After occlusal adjustment, uncomplicated healing and periapical repair occurred in both cases. The findings in these two cases suggest that occlusal trauma may play a role in the healing of periapical pathoses. Occlusal trauma is positively correlated with changes in periodontal tissues. Although experiments in animals have shown that application of forces to teeth will not induce further periodontal destruction, we believe that some failures of root canal treatment may be due to the presence of occlusal trauma modulating the responses of inflamed periapical tissues or apical pathoses with persistent infection.

  1. A Study of Parallelism of the Occlusal Plane and Ala-Tragus Line

    PubMed Central

    Sadr, Katayoun; Sadr, Makan

    2009-01-01

    Background and aims Orientation of the occlusal plane is one of the most important clinical procedures in prostho-dontic rehabilitation of edentulous patients. The aim of this study was to define the best posterior reference point of ala-tragus line for orientation of occlusal plane for complete denture fabrication. Materials and methods Fifty-three dental students (27 females and 26 males) with complete natural dentition and Angel’s Class I occlusal relationship were selected. The subjects were photographed in natural head position while clenching on a Fox plane. After tracing the photographs, the angles between the following lines were measured: the occlusal plane (Fox plane) and the superior border of ala-tragus, the occlusal plane (Fox plane) and the middle of ala-tragus as well as the occlusal plane (Fox plane) and the inferior border of ala-tragus. Descriptive statistics, one sample t-test and independent t-test were used. P value less than 0.05 was considered significant. Results There was no parallelism between the occlusal plane and ala-tragus line with three different posterior ends and one sample t-test showed that the angles between them were significantly different from zero (p<0.05). However, the supe-rior border of ala-tragus line had the lowest mean angle, 1.80° (3.12) and was almost parallel to the occlusal plane. Conclusion The superior border of the tragus is suggested as the posterior reference for ala-tragus line. PMID:23230496

  2. Scaled Tank Test Design and Results for the Aquantis 2.5 MW Ocean Current Generation Device

    DOE Data Explorer

    Swales, Henry; Kils, Ole; Coakley, David B.; Sites, Eric; Mayer, Tyler

    2015-06-03

    Aquantis 2.5 MW Ocean Current Generation Device, Tow Tank Dynamic Rig Structural Analysis Results. This is the detailed documentation for scaled device testing in a tow tank, including models, drawings, presentations, cost of energy analysis, and structural analysis. This dataset also includes specific information on drivetrain, roller bearing, blade fabrication, mooring, and rotor characteristics.

  3. Effect of endovascular reperfusion in relation to site of arterial occlusion.

    PubMed

    Lemmens, Robin; Hamilton, Scott A; Liebeskind, David S; Tomsick, Tom A; Demchuk, Andrew M; Nogueira, Raul G; Marks, Michael P; Jahan, Reza; Gralla, Jan; Yoo, Albert J; Yeatts, Sharon D; Palesch, Yuko Y; Saver, Jeffrey L; Pereira, Vitor M; Broderick, Joseph P; Albers, Gregory W; Lansberg, Maarten G

    2016-02-23

    To assess whether the association between reperfusion and improved clinical outcomes after stroke differs depending on the site of the arterial occlusive lesion (AOL). We pooled data from Solitaire With the Intention for Thrombectomy (SWIFT), Solitaire FR Thrombectomy for Acute Revascularisation (STAR), Diffusion and Perfusion Imaging Evaluation for Understanding Stroke Evolution Study 2 (DEFUSE 2), and Interventional Management of Stroke Trial (IMS III) to compare the strength of the associations between reperfusion and clinical outcomes in patients with internal carotid artery (ICA), proximal middle cerebral artery (MCA) (M1), and distal MCA (M2/3/4) occlusions. Among 710 included patients, the site of the AOL was the ICA in 161, the proximal MCA in 389, and the distal MCA in 160 patients (M2 = 131, M3 = 23, and M4 = 6). Reperfusion was associated with an increase in the rate of good functional outcome (modified Rankin Scale [mRS] score 0-2) in patients with ICA (odds ratio [OR] 3.5, 95% confidence interval [CI] 1.7-7.2) and proximal MCA occlusions (OR 6.2, 95% CI 3.8-10.2), but not in patients with distal MCA occlusions (OR 1.4, 95% CI 0.8-2.6). Among patients with M2 occlusions, a subset of the distal MCA cohort, reperfusion was associated with excellent functional outcome (mRS 0-1; OR 2.2, 95% CI 1.0-4.7). The association between endovascular reperfusion and better clinical outcomes is more profound in patients with ICA and proximal MCA occlusions compared to patients with distal MCA occlusions. Because there are limited data from randomized controlled trials on the effect of endovascular therapy in patients with distal MCA occlusions, these results underscore the need for inclusion of this subgroup in future endovascular therapy trials. © 2016 American Academy of Neurology.

  4. Psychosocial distress of part-time occlusion in children with intermittent exotropia.

    PubMed

    Kim, Ungsoo Samuel; Park, Subin; Yoo, Hee Jeong; Hwang, Jeong-Min

    2013-01-01

    To evaluate the psychosocial distress of part-time occlusion therapy in intermittent exotropia. A total of 25 children (15 males and 10 females, aged 3 to 7 years, mean age 4.7 years) with intermittent exotropia were enrolled. Behavioral and psychosocial problems were assessed by the Korean Child Behavior Checklist (K-CBCL), which consists of eight categories of withdrawal, somatic problems, depression/anxiety, social problems, thought problems, attention problems, delinquent behavior, and aggressive behavior, and the Amblyopia Treatment Index (ATI). The ATI was designed to evaluate the three factors of compliance, adverse effect, and social stigma. The Parenting Stress Index (PSI) is a parent self-report designed to identify potentially dysfunctional parent-child systems. The K-CBCL was obtained before and after occlusion therapy, and the ATI and PSI were taken from parents only after occlusion therapy. We evaluated the change on the K-CBCL and the correlation between the K-CBCL and ATI. The attention problem assessed by the K-CBCL significantly decreased after occlusion therapy. On the ATI, the social stigma was relatively lower than compliance and adverse effect factors (Likert scale 2.64, 3.11, and 3.11, respectively). The somatic problem assessed by the K-CBCL and compliance on the ATI were significantly correlated (p = 0.014). There was no significant change in percentile scores of each subscale (parental dominant scale and child dominant scale) of the PSI. Total stress index before and after occlusion therapy was 97.16 ± 8.38 and 97.00 ± 8.16 respectively (p = 0.382). Occlusion therapy may influence the psychosocial impact on intermittent exotropia patients. Part-time occlusion significantly decreased the attention problem in children with intermittent strabismus. Children with a high somatic problem score on the KCBCL showed poor compliance to the part-time occlusion.

  5. Revascularization experience and results in ischaemic cerebrovascular disease: Moyamoya disease and carotid occlusion.

    PubMed

    Arikan, Fuat; Rubiera, Marta; Serena, Joaquín; Rodríguez-Hernández, Ana; Gándara, Darío; Lorenzo-Bosquet, Carles; Tomasello, Alejandro; Chocrón, Ivette; Quintana-Corvalan, Maximiliano; Sahuquillo, Juan

    2018-03-14

    Cerebral revascularization techniques are an indispensable tool in the current armamentarium of vascular neurosurgeons. We present revascularization surgery experience and results in both moyamoya disease and occlusive cerebral ischaemia. Patients with ischaemic occlusive disease and moyamoya disease who underwent microsurgical revascularization between October 2014 and September 2017 were analysed. In the study period, 23 patients with occlusive ischaemic disease underwent microsurgical revascularization. Three patients presented with serious postoperative complications (2 intraparenchymal haemorrhages in the immediate postoperative period and one thrombosis of the femoral artery). All patients, except one, achieved normalization of the cerebral hemodynamic reserve (CHR) in the SPECT study. Twenty patients had a good neurological result, with no ischaemic recurrence of the revascularized territory. Among patients with moyamoya, 20 had moyamoya disease and 5 had moyamoya syndrome with unilateral involvement. Five patients were treated at paediatric age. Haemorrhagic onset occurred in 2 patients. The CHR study showed hemodynamic compromise in all patients. Cerebral SPECT at one year showed resolution of the hemodynamic failure in all patients. There have been 4 postoperative complications (acute subdural hematoma, two subdural collections and one dehiscence of the surgical wound). No patient presented with neurological worsening at 6 and 12months of follow-up. Cerebral revascularization through end-to-side anastomosis between the superficial temporal artery and a cortical branch of the middle cerebral artery is an indisputable technique in the treatment of moyamoya disease and possibly in a subgroup of patients with symptomatic occlusive ischaemic cerebrovascular disease. Copyright © 2018 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Influence of blood flow occlusion on the development of peripheral and central fatigue during small muscle mass handgrip exercise

    PubMed Central

    Broxterman, R M; Craig, J C; Smith, J R; Wilcox, S L; Jia, C; Warren, S; Barstow, T J

    2015-01-01

    Abstract The influence of the muscle metabolic milieu on peripheral and central fatigue is currently unclear. Moreover, the relationships between peripheral and central fatigue and the curvature constant (W ′) have not been investigated. Six men (age: 25 ± 4 years, body mass: 82 ± 10 kg, height: 179 ± 4 cm) completed four constant power handgrip tests to exhaustion under conditions of control exercise (Con), blood flow occlusion exercise (Occ), Con with 5 min post-exercise blood flow occlusion (Con + Occ), and Occ with 5 min post-exercise blood flow occlusion (Occ + Occ). Neuromuscular fatigue measurements and W ′ were obtained for each subject. Each trial resulted in significant peripheral and central fatigue. Significantly greater peripheral (79.7 ± 5.1% vs. 22.7 ± 6.0%) and central (42.6 ± 3.9% vs. 4.9 ± 2.0%) fatigue occurred for Occ than for Con. In addition, significantly greater peripheral (83.0 ± 4.2% vs. 69.0 ± 6.2%) and central (65.5 ± 14.6% vs. 18.6 ± 4.1%) fatigue occurred for Occ + Occ than for Con + Occ. W ′ was significantly related to the magnitude of global (r = 0.91) and peripheral (r = 0.83) fatigue. The current findings demonstrate that blood flow occlusion exacerbated the development of both peripheral and central fatigue and that post-exercise blood flow occlusion prevented the recovery of both peripheral and central fatigue. Moreover, the current findings suggest that W ′ may be determined by the magnitude of fatigue accrued during exercise. Key points Critical power represents an important threshold for neuromuscular fatigue development and may, therefore, dictate intensities for which exercise tolerance is determined by the magnitude of fatigue accrued. Peripheral fatigue appears to be constant across O2 delivery conditions for large muscle mass exercise, but this consistency is equivocal for smaller muscle mass exercise. We sought to determine the influence of blood flow

  7. Evidence Relating Subjective Contours and Interpretations Involving Occlusion.

    DTIC Science & Technology

    1981-06-01

    This article describes a patient with visual agnosia who is both unable to make the usual occlusion interpretations and is unable to see subjective...article describes a patient with visual agnosia who is both unable to make the usual occlusion interpretions and is unable to see subjective contours...Dr. Howard Gardner for providing access to the facilities at Boston Veterans Administration Hospital for examination of the agnosia patient J.R. Also

  8. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    PubMed

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Emission characteristics in solution-processed asymmetric white alternating current field-induced polymer electroluminescent devices

    NASA Astrophysics Data System (ADS)

    Chen, Yonghua; Xia, Yingdong; Smith, Gregory M.; Gu, Yu; Yang, Chuluo; Carroll, David L.

    2013-01-01

    In this work, the emission characteristics of a blue fluorophor poly(9, 9-dioctylfluorene) (PFO) combined with a red emitting dye: Bis(2-methyl-dibenzo[f,h]quinoxaline)(acetylacetonate)iridium (III) [Ir(MDQ)2(acac)], are examined in two different asymmetric white alternating current field-induced polymer electroluminescent (FIPEL) device structures. The first is a top-contact device in which the triplet transfer is observed resulting in the concentration-dependence of the emission similar to the standard organic light-emitting diode (OLED) structure. The second is a bottom-contact device which, however, exhibits concentration-independence of emission. Specifically, both dye emission and polymer emission are found for the concentrations as high as 10% by weight of the dye in the emitter. We attribute this to the significant different carrier injection characteristics of the two FIPEL devices. Our results suggest a simple and easy way to realize high-quality white emission.

  10. A cephalometric study to determine the plane of occlusion in completely edentulous patients.

    PubMed

    Hindocha, Amit D; Vartak, Vikas N; Bhandari, Aruna J; Dudani, Mohit T

    2013-01-01

    Determination of the plane of occlusion in completely edentulous patients with the help of the ala-tragus line (Camper's plane) may be questioned. An attempt to devise an alternative method to determine the orientation of the plane of occlusion was made. Cephalometric analysis was used to identify whether a correlation exists between the plane of occlusion of dentulous Indian individuals and other stable cranial landmarks. A negative correlation was found to exist between the occlusal Plane-FH plane angle and the porion-nasion-anterior nasal spine (PoNANS) angle. From the derived mathematical correlation, it was concluded that the angulation of the occlusal plane in completely edentulous subjects may be determined by taking a cephalogram at the diagnostic stage. Further, the clinical applicability of the derived mathematical formula (while determining the plane of occlusion) was tested on completely edentulous patients.

  11. Mechanical thrombectomy in acute embolic stroke: preliminary results with the revive device.

    PubMed

    Rohde, Stefan; Haehnel, Stefan; Herweh, Christian; Pham, Mirko; Stampfl, Sibylle; Ringleb, Peter A; Bendszus, Martin

    2011-10-01

    The purpose of this study was to evaluate the safety and technical feasibility of a new thrombectomy device (Revive; Micrus Endovascular) in the endovascular treatment of acute ischemic stroke. Ten patients with acute large vessel occlusions were treated with the Revive device between October 2010 and December 2010. Mean National Institutes of Health Stroke Scale on admission was 19.0; mean duration of symptoms was 172 minutes. Recanalization was assessed using the Thrombolysis In Cerebral Infarction score. Clinical outcome (National Institutes of Health Stroke Scale) after thrombectomy was determined on Day 1, at discharge, and at Day 30. Vessel recanalization (Thrombolysis In Cerebral Infarction 2b or 3) was successful in all patients without device-related complications. Mean National Institutes of Health Stroke Scale 24 hours after the intervention, at discharge, and at Day 30 was 14.0, 11.5, and 5.1, respectively. At Day 30, 6 patients had a clinical improvement of >8 points or an National Institutes of Health Stroke Scale of 0 to 1, 1 patient showed minor improvement, and 3 patients had died. Symptomatic intracranial hemorrhage occurred in 2 patients, of which 1 was fatal. Thrombectomy with the Revive device in patients with stroke with acute large vessel occlusions demonstrated to be technically safe and highly effective. Clinical safety and efficacy have to be established in larger clinical trials.

  12. Transantral distraction devices in correction of severe maxillary deformity in cleft patients.

    PubMed

    Shokirov, Shokhruh; Wangerin, Konrad

    2011-01-01

    Maxillary advancement by Le Fort I osteotomy in cleft patients has an average relapse of about 40-60 percent. With extraoral distraction devices it is possible to obtain an almost unlimited advancement of the upper jaw. Due to the social problems the retention period is normally reduced to some monthes. A relapse of 10-25 % can be seen in these cases. Le Fort I internal distraction osteogenesis offers an alternative to one-step orthognathic advancement, with advantages of gradual lengthening through scar and earlier treatment in growing patients. The objective of this study was to present our experience in the treatment of maxillary deficiency in cleft patients using transantral internal distraction devices. The distraction procedure was successfully accomplished in seventeen patients. For all the seventeen patients maxillary distraction device designed by Konrad Wangerin was used. The distraction distances were 8 to 24 mm. Preoperative, postoperative, and follow-up (12 and 24 months) lateral cephalogram measurements were compared including angular and linear changes. A good new bone was found that was formed in distraction pitch between lines of osteotomy. After distraction of median facial zone, occlusion and profile of soft tissues were considerably improved. All patients after postoperative time required final orthodontic treatment and their final occlusal relationships were satisfactory. The transantral distraction device is a new option for the treatment of severe maxillary hypoplasia in cleft patients.

  13. Effect of mandibular advancement device on sleep bruxism score and sleep quality.

    PubMed

    Solanki, Nehal; Singh, Balendra Pratap; Chand, Pooran; Siddharth, Ramashankar; Arya, Deeksha; Kumar, Lakshya; Tripathi, Suryakant; Jivanani, Hemant; Dubey, Abhishek

    2017-01-01

    The use of mandibular advancement devices (MADs) in the treatment of sleep bruxism is gaining widespread importance. However, the effects of MADs on sleep bruxism scores, sleep quality, and occlusal force are not clear. The purpose of this clinical study was to analyze the effect of MADs on sleep bruxism scores, sleep quality, and occlusal force. This uncontrolled before and after study enrolled 30 participants with sleep bruxism. Outcomes assessed were sleep quality, sleep bruxism scores (sleep bruxism bursts and sleep bruxism episodes/hour), and occlusal force before and after 15 and 30 days of using a MAD. Sleep bruxism scores were assessed by ambulatory polysomnography and sleep quality by using the Pittsburgh sleep quality index (PSQI). Occlusal force was recorded by using a digital gnathodynamometer in the first molar region on both sides. Statistical analysis was done by 1-factor repeated measures ANOVA (α=.05). Statistically significant reductions in sleep bruxism bursts/h, sleep bruxism episodes/h, and PSQI scores were found after 15 and 30 days of using a MAD (P<.001). Statistically significant reduction in occlusal force on both sides was found only after 15 days (P<.001) but not after 30 days of using a MAD (P=.292 on left side, and P=.575 on the right side). The study showed a short-term improvement in sleep bruxism scores, sleep quality, and reduction in occlusal force in sleep bruxism participants after using MADs. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Low profile, highly configurable, current sharing paralleled wide band gap power device power module

    DOEpatents

    McPherson, Brice; Killeen, Peter D.; Lostetter, Alex; Shaw, Robert; Passmore, Brandon; Hornberger, Jared; Berry, Tony M

    2016-08-23

    A power module with multiple equalized parallel power paths supporting multiple parallel bare die power devices constructed with low inductance equalized current paths for even current sharing and clean switching events. Wide low profile power contacts provide low inductance, short current paths, and large conductor cross section area provides for massive current carrying. An internal gate & source kelvin interconnection substrate is provided with individual ballast resistors and simple bolted construction. Gate drive connectors are provided on either left or right size of the module. The module is configurable as half bridge, full bridge, common source, and common drain topologies.

  15. Laser restoration of flow in occluded ventricular shunts for pediatric neurosurgery

    NASA Astrophysics Data System (ADS)

    Christens-Barry, William A.; Guarnieri, Michael; Carson, Benjamin S.

    1998-01-01

    We have investigated the use of short pulses of infrared ((lambda) equals 2.09 micrometers ) light from a Ho:YAG laser to photofragment occlusions and restore flow in ventricular shunts, which provide the sole means of maintaining proper intracranial pressure in hydrocephalus patients. These experiments employed model tissues, a polymeric model compound, and patient explants in order to determine appropriate pulse energies and delivery rates for removal of occlusions material. Laser energy doses and rates of occlusion removal were established for these materials. Laser energy doses that do not damage the shunt device or surrounding tissue were identified. Optical fibers (25 ga. or smaller) can be introduced through the dome of current shunt devices and threaded to the occlusion site. Clinical application will require the continued development of an introducer tool for the transcutaneous insertion of the optical fiber into the shunt device and irrigation techniques for removing the occlusion detritus generated by photofragmentation treatment. Using this approach, a minimally invasive and benign procedure for in situ restoration of flow in occluded neurological implant devices becomes possible.

  16. Interdisciplinary treatment of bruxism with an occlusal splint and cognitive behavioral therapy.

    PubMed

    Trindade, Marilene; Orestes-Cardoso, Silvana; de Siqueira, Teresa Cristina

    2015-01-01

    The etiology of bruxism is associated with exogenous factors, such as occlusal interference, stress, and anxiety, as well as endogenous factors involving neurotransmitters of the basal ganglia. Due to the multifactorial etiology of bruxism, interdisciplinary treatment involving professionals from different healthcare fields has been proposed. The aim of the present study was to compare 2 groups of patients with bruxism (11 in each group) treated with either an occlusal splint combined with cognitive behavioral therapy or an occlusal splint alone. Surface electromyography of the masseter and anterior temporal muscles at rest was performed before and after treatment. The mean amplitude of activity of all muscles was lower after treatment, except for the right anterior temporal muscle in the group treated with an occlusal splint alone. Mean amplitudes were greater in the anterior temporal muscles than in the masseter muscles. Significantly greater improvement was found in the group exposed to cognitive behavioral therapy (P < 0.05; analysis of variance and Student t tests). Therefore, the combination of occlusal splint and psychological therapy was more effective at achieving muscle relaxation than occlusal splint use alone.

  17. Reduction of deviation angle during occlusion therapy: in partially accommodative esotropia with moderate amblyopia.

    PubMed

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa; Kwon, Jung Yoon

    2007-09-01

    To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Mean deviation angle with glasses at the start of occlusion treatment was 19.45+/-5.97 PD and decreased to 12.14+/-12.96 PD at 2 years after occlusion therapy (p<0.01). After occlusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia.

  18. Reduction of Deviation Angle During Occlusion Therapy: In Partially Accommodative Esotropia with Moderate Amblyopia

    PubMed Central

    Chun, Bo Young; Kwon, Soon Jae; Chae, Sun Hwa

    2007-01-01

    Purpose To evaluate changes in ocular alignment in partially accommodative esotropic children age ranged from 3 to 8 years during occlusion therapy for amblyopia. Methods Angle measurements of twenty-two partially accommodative esotropic patients with moderate amblyopia were evaluated before and at 2 years after occlusion therapy. Results Mean deviation angle with glasses at the start of occlusion treatment was 19.45±5.97 PD and decreased to 12.14±12.96 PD at 2 years after occlusion therapy (p<0.01). After occlusion therapy, 9 (41%) cases were indications of surgery for residual deviation but if we had planned surgery before occlusion treatment, 18 (82%) of patients would have had surgery. There was a statistical relationship between increase of visual acuity ratio and decrease of deviation angle (r=-0.479, p=0.024). Conclusions There was a significant reduction of deviation angle of partially accommodative esotropic patients at 2 years after occlusion therapy. Our results suggest that occlusion therapy has an influence on ocular alignment in partially accommodative esotropic patients with amblyopia. PMID:17804922

  19. Transcatheter vessel occlusion: angiographic results versus clinical success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feldman, L.; Greenfield, A.J.; Waltman, A.C.

    1983-04-01

    A review was made of 219 transcatheter vessel occlusion procedures performed over a ten-year period for control of hemorrhage, tumor palliation, or blood supply redistribution prior to intra-arterial chemotherapy. Complete angiographic success was obtained in 85% of the procedures, with partial success in 8%; complete clinical success was achieved in 53% of patients, with partial success in 23%. the most satisfactory clinical results were obtained with hemorrhagic gastritis and pelvic trauma. Embolizations for duodenal ulcer hemorrhage and transhepatic variceal occlusion were the least clinically successful, although isobutyl-cyanoacrylate appeared to be a significant improvement in angiographic therapy for duodenal ulcer. Themore » overall complication rate was 13%, with one third of the complications clinically silent. These results indicate that transcatheter vessel occlusion is a relatively safe and effective method for control of hemorrhage or tumor infarction.« less

  20. Nonlinear current-voltage characteristics based on semiconductor nanowire networks enable a new concept in thermoelectric device optimization

    NASA Astrophysics Data System (ADS)

    Diaz Leon, Juan J.; Norris, Kate J.; Hartnett, Ryan J.; Garrett, Matthew P.; Tompa, Gary S.; Kobayashi, Nobuhiko P.

    2016-08-01

    Thermoelectric (TE) devices that produce electric power from heat are driven by a temperature gradient (Δ T = T_{{hot}} - T_{{cold}}, T hot: hot side temperature, T cold: cold side temperature) with respect to the average temperature ( T). While the resistance of TE devices changes as Δ T and/or T change, the current-voltage ( I- V) characteristics have consistently been shown to remain linear, which clips generated electric power ( P gen) within the given open-circuit voltage ( V OC) and short-circuit current ( I SC). This P gen clipping is altered when an appropriate nonlinearity is introduced to the I- V characteristics—increasing P gen. By analogy, photovoltaic cells with a large fill factor exhibit nonlinear I- V characteristics. In this paper, the concept of a unique TE device with nonlinear I- V characteristics is proposed and experimentally demonstrated. A single TE device with nonlinear I- V characteristics is fabricated by combining indium phosphide (InP) and silicon (Si) semiconductor nanowire networks. These TE devices show P gen that is more than 25 times larger than those of comparable devices with linear I- V characteristics. The plausible causes of the nonlinear I- V characteristics are discussed. The demonstrated concept suggests that there exists a new pathway to increase P gen of TE devices made of semiconductors.

  1. Implications of Natural Occlusion of Ventilated Racks on Ammonia and Sanitation Practices

    PubMed Central

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-01-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague–Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded. PMID:24602544

  2. Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.

    PubMed

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-03-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague-Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded.

  3. Inability to perform posterior segment monitoring by scanning laser ophthalmoscopy or optical coherence tomography with some occlusive intraocular lenses in clinical use.

    PubMed

    Yusuf, Imran H; Peirson, Stuart N; Patel, Chetan K

    2012-03-01

    To evaluate whether occlusive intraocular lenses (IOLs) produced by several manufacturers for clinical use equivalently transmit near-infrared (IR) light for scanning laser ophthalmoscopy (SLO) or optical coherence tomography (OCT) imaging. Nuffield Laboratory of Ophthalmology, Oxford University, United Kingdom. Evaluation of diagnostic test or technology. The study evaluated 6 black IOLs of 2 designs: 3 poly(methyl methacrylate) (PMMA) and 3 iris-claw anterior chamber IOLs. Each IOL was placed between a broad-spectrum white light source and a spectroradiometer to generate transmission spectra. Transmission in the near-IR range was examined using an 850 nm light-emitting diode. Scanning laser ophthalmoscopy or OCT imaging using Spectralis spectral-domain SLO or OCT was attempted through occlusive IOLs in a model eye. Artisan iris-claw and MS 612 PMMA occlusive IOLs totally occluded all wavelengths of light, including in the near IR range in which SLO and OCT imaging systems operate. It was not possible to capture SLO or OCT images through the iris-claw and PMMA occlusive IOLs in a model eye. Results suggest the property of near-IR transmission that permits SLO or OCT imaging through occlusive IOLs is restricted to the Morcher range of occlusive IOLs. Patients with non-near IR transmitting IOLs will not be able to receive detailed posterior segment monitoring with SLO or OCT. This finding may have a significant impact on preoperative occlusive IOL selection and the management of current patients with occlusive IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Postprocedural, midterm, and long-term results of cerebral aneurysms treated with flow-diverter devices: 7-year experience at a single center.

    PubMed

    Briganti, Francesco; Leone, Giuseppe; Cirillo, Luigi; de Divitiis, Oreste; Solari, Domenico; Cappabianca, Paolo

    2017-06-01

    OBJECTIVE Flow diversion has emerged as a viable treatment option for selected intracranial aneurysms and recently has been gaining traction. The aim of this study was to evaluate the safety and effectiveness of flow-diverter devices (FDDs) over a long-term follow-up period. METHODS The authors retrospectively reviewed all cerebral aneurysm cases that had been admitted to the Division of Neurosurgery of the Università degli Studi di Napoli between November 2008 and November 2015 and treated with an FDD. The records of 60 patients (48 females and 12 males) harboring 69 cerebral aneurysms were analyzed. The study end points were angiographic evidence of complete aneurysm occlusion, recanalization rate, occlusion of the parent artery, and clinical and radiological evidence of brain ischemia. The occlusion rate was evaluated according to the O'Kelly-Marotta (OKM) Scale for flow diversion, based on the degree of filling (A, total filling; B, subtotal filling; C, entry remnant; D, no filling). Postprocedural, midterm, and long-term results were strictly analyzed. RESULTS Complete occlusion (OKM D) was achieved in 63 (91%) of 69 aneurysms, partial occlusion (OKM C) in 4 (6%), occlusion of the parent artery in 2 (3%). Intraprocedural technical complications occurred in 3 patients (5%). Postprocedural complications occurred in 6 patients (10%), without neurological deficits. At the 12-month follow-up, 3 patients (5%) experienced asymptomatic cerebral infarction. No further complications were observed at later follow-up evaluations (> 24 months). There were no reports of any delayed aneurysm rupture, subarachnoid or intraparenchymal hemorrhage, ischemic complications, or procedure- or device-related deaths. CONCLUSIONS Endovascular treatment with an FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. In the present study, the authors observed effective and stable aneurysm occlusion, even at the long-term follow-up. Data in this

  5. Visual Acuity Improvement in Continuous vs Divided Occlusion in Anisometropic Amblyopia

    PubMed Central

    Irfani, Irawati; Feriyanto, Feri; Oktarima, Primawita; Kartasasmita, Arief

    2018-01-01

    Purpose: To compare visual acuity improvement between continuous and split part-time occlusion for the treatment of moderate and severe anisometropic amblyopia. Methods: Randomised clinical trials in 6 – 13 y.o children with moderate and severe anisometropic amblyopia. Each patient was consecutively selected with continuous or split part-time occlusion. Best corrected visual acuity’s improvement was followed up to six weeks and statistical data were analyzed using chi square and unpaired t-test. Results: Best corrected visual acuity’s improvement was comparable between continuous and split part-time occlusion (0.20±0.27 vs 0.21±0.25; p = 0.79). Conclusion: Split part-time occlusion may be considered as an alternative treatment for moderate and severe anisometropic amblyopia treatment. PMID:29515681

  6. Occlus-o-Guide® versus Andresen activator appliance: neuromuscular evaluation.

    PubMed

    Farronato, Giampietro; Giannini, Lucia; Galbiati, Guido; Grillo, Elena; Maspero, Cinzia

    2013-05-20

    The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-Guide® and Andresen activator appliances. Eighty-two patients (35 males and 47 females) aged between 8 and 12 years (mean age, 10.5±0.8 years) participated in the study. Fifty patients underwent treatment with an Occlus-o-Guide® and 32 patients with an Andresen activator. All patients underwent EMG examination using a Freely EMG (De Gotzen, Legnano, Italy) and surface bipolar electrodes when the appliances were worn for the first time (T0), and after 6 months (T1) and after 12 months (T2) of appliance use. Statistical analysis showed that both at T0 and T2, the percent overlapping coefficient (POC) of the anterior temporalis muscles was not statistically different between the appliance groups. At T0, the POC of the masseter muscles was significantly lower for the Andresen appliance as compared to the Occlus-o-Guide® (p=0.02), while at T2 this significance was lost. At insertion of an appliance, all patients show neuromuscular balance that does not correspond to orthognathic occlusion. Both appliances work by creating muscular imbalance. With the appliances in situ, EMG responses were generally analogous for the Occlus-o-Guide® and the Andresen activator; however, the imbalance was greater and the recovery of the orthological muscular balance was slower in patients under treatment with the Andresen activator as compared to those with the Occlus-o-Guide®.

  7. Biased low differential input impedance current receiver/converter device and method for low noise readout from voltage-controlled detectors

    DOEpatents

    Degtiarenko, Pavel V [Williamsburg, VA; Popov, Vladimir E [Newport News, VA

    2011-03-22

    A first stage electronic system for receiving charge or current from voltage-controlled sensors or detectors that includes a low input impedance current receiver/converter device (for example, a transimpedance amplifier), which is directly coupled to the sensor output, a source of bias voltage, and the device's power supply (or supplies), which use the biased voltage point as a baseline.

  8. Post market surveillance in the german medical device sector - current state and future perspectives.

    PubMed

    Zippel, Claus; Bohnet-Joschko, Sabine

    2017-08-01

    Medical devices play a central role in the diagnosis and treatment of diseases but also bring the potential for adverse events, hazards or malfunction with serious consequences for patients and users. Medical device manufacturers are therefore required by law to monitor the performance of medical devices that have been approved by the competent authorities (post market surveillance). Conducting a nationwide online-survey in the German medical device sector in Q2/2014 in order to explore the current status of the use of post market instruments we obtained a total of 118 complete data sets, for a return rate of 36%. The survey included manufacturers of different sizes, producing medical devices of all risk classes. The post market instruments most frequently reported covered the fields of production monitoring and quality management as well as literature observation, regulatory vigilance systems, customer knowledge management and market observation while Post Market Clinical Follow-up and health services research were being used less for product monitoring. We found significant differences between the different risk classes of medical devices produced and the intensity of use of post market instruments. Differences between company size and the intensity of instruments used were hardly detected. Results may well contribute to the development of device monitoring which is a crucial element of the policy and regulatory system to identify device-related safety issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Essure Microinsert Abdominal Migration after Hysteroscopic Tubal Sterilization of an Appropriately Placed Essure Device: Dual Case Reports and Review of the Literature

    PubMed Central

    Rezai, Shadi; LaBine, Meghan; Gomez Roberts, Hunter Azdel; Lora Alcantara, Isamarie; Henderson, Cassandra E.; Elmadjian, Malvina; Nuritdinova, Dilfuza

    2015-01-01

    Background. The Essure device is a method of permanent sterilization widely used in the US that has proven to be safe and effective in most cases. However, there have been reports of device migration that have led to failed tubal occlusion as well as several other serious complications resulting from the presence of the device in the abdominal cavity. Case. This paper represents two cases of failed tubal occlusion by an appropriately placed Essure device without signs or symptoms of further complications related to device migration. Conclusion. Although there have only been 13 reported cases of abdominal device migration since November 2014, this case indicates that the actual number may be higher than reported since it is possible for migration to occur without additional complications. In the majority of reported cases of abdominal migration a major complication requiring surgical correction occurred, such as adhesions, small bowel obstruction, bowel perforation, or persistent pelvic pain. To avoid these complications it is recommended that migrating implants be removed; however, this case also represents an example of when a migrating device may remain in situ in an asymptomatic patient. PMID:26664781

  10. Occlusion and Temporomandibular Function among Subjects with Mandibular Distal Extension Removable Partial Dentures

    PubMed Central

    Creugers, N. H. J.; Witter, D. J.; Van 't Spijker, A.; Gerritsen, A. E.; Kreulen, C. M.

    2010-01-01

    Objective. To quantify effects on occlusion and temporomandibular function of mandibular distal extension removable partial dentures in shortened dental arches. Methods. Subjects wearing mandibular extension removable partial dentures (n = 25) were compared with subjects with shortened dental arches without extension (n = 74) and with subjects who had worn a mandibular extension removable partial denture in the past (n = 19). Subjects with complete dentitions (n = 72) were controls. Data were collected at baseline and at 3-, 6-, and 9-year observations. Results. Occlusal activity in terms of reported awareness of bruxism and occlusal tooth wear of lower anterior teeth did not differ significantly between the groups. In contrast, occlusal tooth wear of premolars in shortened dental arches with or without extension dentures was significantly higher than in the controls. Differences amongst groups with respect to signs and symptoms related to temporomandibular disorders were not found. Occlusal support of the dentures did not influence anterior spatial relationship. Occlusal contacts of the denture teeth decreased from 70% for second premolars via 50% for first molars, to 30% for second molars. Conclusions. Mandibular distal extension removable partial dentures in moderate shortened dental arches had no effects on occlusion and temporomandibular function. PMID:20671961

  11. Occlusal enamel complexity in middle miocene to holocene equids (Equidae: Perissodactyla) of North America.

    PubMed

    Famoso, Nicholas A; Davis, Edward Byrd

    2014-01-01

    Four groups of equids, "Anchitheriinae," Merychippine-grade Equinae, Hipparionini, and Equini, coexisted in the middle Miocene, but only the Equini remains after 16 Myr of evolution and extinction. Each group is distinct in its occlusal enamel pattern. These patterns have been compared qualitatively but rarely quantitatively. The processes influencing the evolution of these occlusal patterns have not been thoroughly investigated with respect to phylogeny, tooth position, and climate through geologic time. We investigated Occlusal Enamel Index, a quantitative method for the analysis of the complexity of occlusal patterns. We used analyses of variance and an analysis of co-variance to test whether equid teeth increase resistive cutting area for food processing during mastication, as expressed in occlusal enamel complexity, in response to increased abrasion in their diet. Results suggest that occlusal enamel complexity was influenced by climate, phylogeny, and tooth position through time. Occlusal enamel complexity in middle Miocene to Modern horses increased as the animals experienced increased tooth abrasion and a cooling climate.

  12. Occlusal status and prevalence of occlusal malocclusion traits among 9-year-old schoolchildren.

    PubMed

    Lux, Christopher J; Dücker, Britta; Pritsch, Maria; Komposch, Gerda; Niekusch, Uwe

    2009-06-01

    The aim of this study was to provide detailed information concerning clinically relevant occlusal traits and the prevalence of occlusal anomalies in an orthodontically relevant period of dental development. Four hundred and ninety-four German schoolchildren (237 males and 257 females), median age 9 years, were orthodontically examined. Overjet and overbite were measured to the nearest 0.5 mm, and sagittal molar relationships were registered clinically to the nearest quarter unit. In addition, crossbites, scissor bites, and midline displacements were evaluated. Descriptive statistics was complemented by testing gender differences and differences between groups with Class I and Class II anomalies (Mann-Whitney U-test) as well as a statistical evaluation of differences between the three dental stages (Kruskal-Wallis test). Overjet exhibited an extreme range between -2 and 12 mm (median values 3-3.5 mm). An increased overjet was more prevalent than a reduced or reverse overjet, and a severely increased overjet greater than 6 mm was a common finding affecting around 5-10 per cent of the children. Similarly, overbite showed considerable variations of between -1 and 9 mm (medians 3-3.5 mm) and males exhibited a significantly larger overbite than females. In Class II malocclusion subjects, overbite was significantly enlarged (on average between 0.5 and 1 mm) when compared with those with a Class I malocclusion. Traumatic contact of the gingiva affected every 14th child. A Class II molar relationship of three-quarter units or more was a frequent finding affecting more than one child in five. In addition, at 9 years of age, 3 per cent of the children exhibited a Class III molar relationship of at least a half unit. The wide range of orthodontically relevant occlusal traits found in the present study underlines the need for orthodontic screening at 9 years of age (or earlier).

  13. Relative contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance.

    PubMed

    Lepley, Casey R; Throckmorton, Gaylord S; Ceen, Richard F; Buschang, Peter H

    2011-05-01

    The purpose of this study was to explore the contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance. A prospective cross-sectional study was performed on 30 subjects with Class I occlusion. Masticatory performance was measured with the test food Cuttersil (Heraeus Kulzer, South Bend, Ind) and the fractional-sieve technique. Blu-Mousse (Parkell Biomaterials, Farmingdale, NY) bite registrations were used to measure occlusal contact areas. The American Board of Orthodontics occlusal discrepancies were measured on the subjects' dental models. Maximum bite forces were recorded with a custom transducer, and 3-dimensional chewing cycle kinematics were tracked with an opto-electric computer system and Optotrak software (Northern Digital, Waterloo, Ontario, Canada). Masticatory performance was most closely correlated with occlusal contact area, indicating larger contact areas in subjects with better performance. Occlusal contact area and occlusal discrepancies were also related to bite force and chewing cycle kinematics. Maximum bite force was positively related with masticatory performance. Although masticatory performance is related, both directly and indirectly, to a number of morphologic and functional factors, it is most closely related to occlusal factors. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  14. Management of Retinal Vein Occlusion, Who Is Responsible?

    PubMed

    Aghamirsalim, Mohamadreza; Sorbi, Reza; Naderian, Mohammadreza; Cugati, Sudha; Shahsuvaryan, Marianne Levon; Ghazizadeh Hashemi, Maryam

    2016-11-01

    Retinal vein occlusion (RVO) is a common retinal vascular occlusive disorder and is associated with a variety of systemic risk factors. The aim of this study was to investigate whether the underlying diseases were evaluated and managed appropriately by ophthalmologists. We performed a study of 1344 patients with retinal vein occlusion (RVO). Patients were evaluated with a questionnaire including ten closed questions to determine whether ophthalmologists evaluated and informed their patients about the underlying systemic diseases. None of the patients' homocysteine levels were measured. Only a small percentage of the patients were asked about the history of thrombotic diseases or family history of thrombotic diseases. We believe that most ophthalmologists are still not entirely convinced of their responsibility of managing the underlying predisposing factors of RVO. Ophthalmologists should either manage or engage other healthcare providers in the management of RVO to guarantee the patient the best care.

  15. The dental literature on occlusion and myogenous orofacial pain: application of critical thinking.

    PubMed

    Solow, Roger Alan

    2016-09-01

    To enhance the reader's critical thinking when reading the dental literature on the relationship of occlusion and myogenous orofacial pain (MOP). Representative journal articles and systematic reviews from the dental literature confirming and denying a relationship of occlusion to MOP were analyzed and reviewed. Studies using computerized occlusal analysis (COA) consistently find a relationship of the occlusion to MOP. Studies that do not confirm this relationship have problems with invalid primary source conclusions, unstated assumptions, bias, and errors in logic that disqualify their conclusion. This review explains four categories of problems with the dental literature that denies occlusion has a relationship with MOP. When the reader understands these examples of flaws in this literature, they can apply this critical thinking to future studies. Correct interpretation of the literature on occlusion and MOP requires a foundation of basic and clinical scientific knowledge as well as an understanding of the details of the primary source articles.

  16. Ambient occlusion effects for combined volumes and tubular geometry.

    PubMed

    Schott, Mathias; Martin, Tobias; Grosset, A V Pascal; Smith, Sean T; Hansen, Charles D

    2013-06-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed.

  17. Ambient Occlusion Effects for Combined Volumes and Tubular Geometry

    PubMed Central

    Schott, Mathias; Martin, Tobias; Grosset, A.V. Pascal; Smith, Sean T.; Hansen, Charles D.

    2013-01-01

    This paper details a method for interactive direct volume rendering that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube-shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The algorithm extends the recently presented the directional occlusion shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. Stream tube geometries are computed using an effective spline-based interpolation and approximation scheme that avoids self-intersection and maintains coherent orientation of the stream tube segments to avoid surface deforming twists. Furthermore, strategies to reduce the geometric and specular aliasing of the stream tubes are discussed. PMID:23559506

  18. Current Radiation Issues for Programmable Elements and Devices

    NASA Technical Reports Server (NTRS)

    Katz, R.; Wang, J. J.; Koga, R.; LaBel, A.; McCollum, J.; Brown, R.; Reed, R. A.; Cronquist, B.; Crain, S.; Scott, T.; hide

    1998-01-01

    State of the an programmable devices are utilizing advanced processing technologies, non-standard circuit structures, and unique electrical elements in commercial-off-the-shelf (COTS)-based, high-performance devices. This paper will discuss that the above factors, coupled with the systems application environment, have a strong interplay that affect the radiation hardness of programmable devices and have resultant system impacts in (1) reliability of the unprogrammed, biased antifuse for heavy ions (rupture), (2) logic upset manifesting itself as clock upset, and (3) configuration upset. General radiation characteristics of advanced technologies are examined and manufacturers' modifications to their COTS-based and their impact on future programmable devices will be analyzed.

  19. Effect of occlusal interference on habitual activity of human masseter.

    PubMed

    Michelotti, A; Farella, M; Gallo, L M; Veltri, A; Palla, S; Martina, R

    2005-07-01

    It has been suggested that occlusal interference may increase habitual activity in the jaw muscles and may lead to temporomandibular disorders (TMD). We tested these hypotheses by means of a double-blind randomized crossover experiment carried out on 11 young healthy females. Strips of gold foil were glued either on a selected occlusal contact area (active interference) or on the vestibular surface of the same tooth (dummy interference) and left for 8 days each. Electromyographic masseter activity was recorded in the natural environment by portable recorders under interference-free, dummy-interference, and active-interference conditions. The active occlusal interference caused a significant reduction in the number of activity periods per hour and in their mean amplitude. The EMG activity did not change significantly during the dummy-interference condition. None of the subjects developed signs and/or symptoms of TMD throughout the whole study, and most of them adapted fairly well to the occlusal disturbance.

  20. Combined use of rapid-prototyping model and surgical guide in correction of mandibular asymmetry malformation patients with normal occlusal relationship.

    PubMed

    Xu, Haisong; Zhang, Ce; Shim, Yoong Hoon; Li, Hongliang; Cao, Dejun

    2015-03-01

    The aim of this study is to discuss the application of rapid-prototyping model and surgical guide in the treatment of mandibular asymmetry malformation with normal occlusal relationship. Twenty-four mandibular asymmetry malformation patients with relatively normal occlusal relationship were included in this study. Surgical 3-dimensional rapid-prototyping mandibular models were made for all patients from the computed tomography (CT) DICOM data. The presurgical plan was designed on the model, and the surgical guiders for the osteotomy lines were manufactured. Genioplasty and/or mandibular osteotomy based on the presurgical plan were performed on these patients with the combined use of the rapid-prototyping model and surgical guides. All patients underwent postoperative CT scan and had at least 3-month follow-up. All patients were satisfied with the final results. According to the postoperative CT images and 3-month follow-up, all patients' mandibular asymmetry malformation was significantly improved, and the operation time was distinctly shortened relative to the conventional method. Rapid-prototyping model and surgical guide are viable auxiliary devices for the treatment of mandibular asymmetry malformation with relatively normal occlusal relationship. Combined use of them can make precise preoperative design, improve effects of operation, and shorten operating time.

  1. Mechanical thrombectomy for acute ischemic stroke with occlusion of the M2 segment of the middle cerebral artery: a meta-analysis.

    PubMed

    Saber, Hamidreza; Narayanan, Sandra; Palla, Mohan; Saver, Jeffrey L; Nogueira, Raul G; Yoo, Albert J; Sheth, Sunil A

    2017-11-10

    Endovascular thrombectomy has demonstrated benefit for patients with acute ischemic stroke from proximal large vessel occlusion. However, limited evidence is available from recent randomized trials on the role of thrombectomy for M2 segment occlusions of the middle cerebral artery (MCA). We conducted a systematic review and meta-analysis to investigate clinical and radiographic outcomes, rates of hemorrhagic complications, and mortality after M2 occlusion thrombectomy using modern devices, and compared these outcomes against patients with M1 occlusions. Recanalization was defined as Thrombolysis in Cerebral Infarction (TICI) 2b/3 or modified TICI 2b/3. A total of 12 studies with 1080 patients with M2 thrombectomy were included in our analysis. Functional independence (modified Rankin Scale 0-2) rate was 59% (95% CI 54% to 64%). Mortality and symptomatic intracranial hemorrhage rates were 16% (95% CI 11% to 23%) and 10% (95% CI 6% to 16%), respectively. Recanalization rates were 81% (95% CI 79% to 84%), and were equally comparable for stent-retriever versus aspiration (OR 1.05; 95% CI 0.91 to 1.21). Successful M2 recanalization was associated with greater rates of favorable outcome (OR 4.22; 95% CI 1.96 to 9.1) compared with poor M2 recanalization (TICI 0-2a). There was no significant difference in recanalization rates for M2 versus M1 thrombectomy (OR 1.05; 95% CI 0.77 to 1.42). This meta-analysis suggests that mechanical thrombectomy for M2 occlusions that can be safely accessed is associated with high functional independence and recanalization rates, but may be associated with an increased risk of hemorrhage. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Handheld pose tracking using vision-inertial sensors with occlusion handling

    NASA Astrophysics Data System (ADS)

    Li, Juan; Slembrouck, Maarten; Deboeverie, Francis; Bernardos, Ana M.; Besada, Juan A.; Veelaert, Peter; Aghajan, Hamid; Casar, José R.; Philips, Wilfried

    2016-07-01

    Tracking of a handheld device's three-dimensional (3-D) position and orientation is fundamental to various application domains, including augmented reality (AR), virtual reality, and interaction in smart spaces. Existing systems still offer limited performance in terms of accuracy, robustness, computational cost, and ease of deployment. We present a low-cost, accurate, and robust system for handheld pose tracking using fused vision and inertial data. The integration of measurements from embedded accelerometers reduces the number of unknown parameters in the six-degree-of-freedom pose calculation. The proposed system requires two light-emitting diode (LED) markers to be attached to the device, which are tracked by external cameras through a robust algorithm against illumination changes. Three data fusion methods have been proposed, including the triangulation-based stereo-vision system, constraint-based stereo-vision system with occlusion handling, and triangulation-based multivision system. Real-time demonstrations of the proposed system applied to AR and 3-D gaming are also included. The accuracy assessment of the proposed system is carried out by comparing with the data generated by the state-of-the-art commercial motion tracking system OptiTrack. Experimental results show that the proposed system has achieved high accuracy of few centimeters in position estimation and few degrees in orientation estimation.

  3. Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience.

    PubMed

    Briganti, Francesco; Leone, Giuseppe; Ugga, Lorenzo; Marseglia, Mariano; Solari, Domenico; Caranci, Ferdinando; Mariniello, Giuseppe; Maiuri, Francesco; Cappabianca, Paolo

    2016-09-01

    Experience with the endovascular treatment of cerebral aneurysms by the Flow Re-Direction Endoluminal Device (FRED) is still limited. The aim of this study is to discuss the results and complications of this new flow diverter device (FDD). Between November 2013 and April 2015, 20 patients (15 female and five male) harboring 24 cerebral aneurysms were treated with FRED FDD in a single center. Complete occlusion was obtained in 20/24 aneurysms (83 %) and partial occlusion in four (17 %). Intraprocedural technical complication occurred in one case (4 %) and post-procedural complications in three (12 %). None reported neurological deficits (mRS = 0). All FRED were patent at follow-up. No early or delayed aneurysm rupture, no subarachnoid (SAH) or intraparenchymal hemorrhage (IPH) no ischemic complications and no deaths occurred. Endovascular treatment with FRED FDD is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. The FRED is substantially equivalent to the other known FDDs, which show similar functions and technical profiles.

  4. Occlus-o-Guide® versus Andresen activator appliance: neuromuscular evaluation

    PubMed Central

    2013-01-01

    Background The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-Guide® and Andresen activator appliances. Methods Eighty-two patients (35 males and 47 females) aged between 8 and 12 years (mean age, 10.5 ± 0.8 years) participated in the study. Fifty patients underwent treatment with an Occlus-o-Guide® and 32 patients with an Andresen activator. All patients underwent EMG examination using a Freely EMG (De Gotzen, Legnano, Italy) and surface bipolar electrodes when the appliances were worn for the first time (T0), and after 6 months (T1) and after 12 months (T2) of appliance use. Results Statistical analysis showed that both at T0 and T2, the percent overlapping coefficient (POC) of the anterior temporalis muscles was not statistically different between the appliance groups. At T0, the POC of the masseter muscles was significantly lower for the Andresen appliance as compared to the Occlus-o-Guide® (p = 0.02), while at T2 this significance was lost. Conclusions At insertion of an appliance, all patients show neuromuscular balance that does not correspond to orthognathic occlusion. Both appliances work by creating muscular imbalance. With the appliances in situ, EMG responses were generally analogous for the Occlus-o-Guide® and the Andresen activator; however, the imbalance was greater and the recovery of the orthological muscular balance was slower in patients under treatment with the Andresen activator as compared to those with the Occlus-o-Guide®. PMID:24325935

  5. Object Correspondence across Brief Occlusion Is Established on the Basis of both Spatiotemporal and Surface Feature Cues

    ERIC Educational Resources Information Center

    Hollingworth, Andrew; Franconeri, Steven L.

    2009-01-01

    The "correspondence problem" is a classic issue in vision and cognition. Frequent perceptual disruptions, such as saccades and brief occlusion, create gaps in perceptual input. How does the visual system establish correspondence between objects visible before and after the disruption? Current theories hold that object correspondence is established…

  6. Intrauterine devices and risk of uterine perforation: current perspectives

    PubMed Central

    Rowlands, Sam; Oloto, Emeka; Horwell, David H

    2016-01-01

    Uterine perforation is an uncommon complication of intrauterine device insertion, with an incidence of one in 1,000 insertions. Perforation may be complete, with the device totally in the abdominal cavity, or partial, with the device to varying degrees within the uterine wall. Some studies show a positive association between lactation and perforation, but a causal relationship has not been established. Very rarely, a device may perforate into bowel or the urinary tract. Perforated intrauterine devices can generally be removed successfully at laparoscopy. PMID:29386934

  7. Occlusal Enamel Complexity in Middle Miocene to Holocene Equids (Equidae: Perissodactyla) of North America

    PubMed Central

    Famoso, Nicholas A.; Davis, Edward Byrd

    2014-01-01

    Four groups of equids, “Anchitheriinae,” Merychippine-grade Equinae, Hipparionini, and Equini, coexisted in the middle Miocene, but only the Equini remains after 16 Myr of evolution and extinction. Each group is distinct in its occlusal enamel pattern. These patterns have been compared qualitatively but rarely quantitatively. The processes influencing the evolution of these occlusal patterns have not been thoroughly investigated with respect to phylogeny, tooth position, and climate through geologic time. We investigated Occlusal Enamel Index, a quantitative method for the analysis of the complexity of occlusal patterns. We used analyses of variance and an analysis of co-variance to test whether equid teeth increase resistive cutting area for food processing during mastication, as expressed in occlusal enamel complexity, in response to increased abrasion in their diet. Results suggest that occlusal enamel complexity was influenced by climate, phylogeny, and tooth position through time. Occlusal enamel complexity in middle Miocene to Modern horses increased as the animals experienced increased tooth abrasion and a cooling climate. PMID:24587267

  8. Evaluation of recovery in lip closing pressure and occlusal force and contact area after orthognathic surgery.

    PubMed

    Ueki, Koichiro; Moroi, Akinori; Sotobori, Megumi; Ishihara, Yuri; Marukawa, Kohei; Iguchi, Ran; Kosaka, Akihiko; Ikawa, Hiroumi; Nakazawa, Ryuichi; Higuchi, Masatoshi

    2014-10-01

    The purpose of this study was to evaluate the relationship between lip closing force, occlusal contact area and occlusal force after orthognathic surgery in skeletal Class III patients. The subjects consisted of 54 patients (28 female and 26 male) diagnosed with mandibular prognathism who underwent sagittal split ramus osteotomy with and without Le Fort I osteotomy. Maximum and minimum lip closing forces, occlusal contact area and occlusal force were measured pre-operatively, 6 months and 1 year post-operative. Maximum and minimum lip closing forces, occlusal contact area and occlusal force increased with time after surgery, however a significant increase was not found in the occlusal contact area in women. In increased ratio (6 months/pre-operative and 1 year/pre-operative), the maximum lip closing force was significantly correlated with the occlusal contact area (P < 0.0001). This study suggested that orthognathic surgery could improve the occlusal force, contact area and lip closing force, and an increase ratio in maximum lip closing force was associated with an increased ratio in occlusal contact area. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Can pulpal floor debonding be detected from occlusal surface displacement in composite restorations?

    PubMed

    Novaes, João Batista; Talma, Elissa; Las Casas, Estevam Barbosa; Aregawi, Wondwosen; Kolstad, Lauren Wickham; Mantell, Sue; Wang, Yan; Fok, Alex

    2018-01-01

    could be detected by using the most accurate intraoral scanners currently available. Thus, subject to clinical validation, the occlusal displacement of a resin composite restoration may be used to assess its interfacial integrity. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old.

    PubMed

    Megbelayin, E; Ekpenyong, S M; Azunobi, J; Ejiro, G

    2014-03-01

    To report a reversal of myopic anisometropic amblyopia with occlusion therapy in a 25 year old. Case report. Eye clinic of a University Teaching Hospital in a metropolitan city. an index patient. Occlusion therapy. Post occlusion visual acuity. Presenting unaided visual acuity of right eye: 6/6, left eye: 4/60. Refraction result was: right eye: -0.50DS (6/6), left eye: -3.50DS (6/18). Following day time occlusion therapy of at least 6 hours for about 4 weeks, subjective refraction was: right eye: -0.5DS (6/5), left eye: -3.50DS (6/6(+3)). The remarkable improvement in vision at age 25 years of a patient with myopic anisometropic amblyopia shows that occlusion therapy might still be useful long after amblyogenic period.

  11. Veno-occlusive disease and primary hepatic vein thrombosis in Israeli Arabs.

    PubMed

    Ghanem, J; Hershko, C

    1981-05-01

    In a survey of nine major Israeli hospitals, 29 patients diagnosed between 1955 and 1975 as suffering from hepatic vein thrombosis were identified. Fifteen of the patients were Jews and 14 were Arabs. In contrast to the Jewish patients, all of whom were adults, the majority of the Arab patients were children below 10 years of age. Primary hepatic vein occlusion was 2.4 times more common among Arab than among Jewish patients. Of the 11 Arab patients with primary hepatic vein occlusion, three had histological changes typical of veno-occlusive disease; whereas in five others, thrombotic occlusion of large hepatic veins or of the vena cava was documented. Although no plant alkaloids could be directly implicated in any of the Arab patients, circumstantial evidence strongly supports such an etiology. All of our Arab patients originated from small agricultural communities where ancient methods of winnowing, which expose the home-ground wheat to a high risk of contamination by grains containing pyrrolizidine alkaloids, are still in use. This report confirms the world-wide distribution of veno-occlusive disease, and under-lines the need for a systematic search for possible sources of poisoning by pyrrolizidine alkaloids.

  12. Influence of stains on lesion contrast in the pits and fissures of tooth occlusal surfaces from 800-1600-nm

    NASA Astrophysics Data System (ADS)

    Almaz, Elias C.; Simon, Jacob C.; Fried, Daniel; Darling, Cynthia L.

    2016-02-01

    For over one hundred years, x-rays have served as a cornerstone of dentistry. Dental radiographic imaging technologies have constantly improved, however, detecting occlusal lesions remains as one of the greatest challenges due to the low sensitivity of radiographs and the overlap of enamel. Once detected, occlusal lesions have penetrated far into the dentin, necessitating invasive restorative treatment. The adoption of near-infrared (NIR) systems in dentistry introduces the potential for early detection of occlusal lesions. Commercially available NIR systems for intra-oral applications currently operate near 800-nm; however, extrinsic stains may interfere with the detection of demineralization of the underlying enamel surface. Higher wavelengths such as 1300-nm render stains nearly transparent and enhances the contrast of sound enamel to demineralized enamel. This novel finding promotes minimally invasive dentistry and allows oral health professionals the ability to detect, image, track, and monitor early lesions without repeated exposure to ionizing radiation nor invasive treatment.

  13. Influence of stains on lesion contrast in the pits and fissures of tooth occlusal surfaces from 800-1600-nm.

    PubMed

    Almaz, Elias C; Simon, Jacob C; Fried, Daniel; Darling, Cynthia L

    2016-02-13

    For over one hundred years, x-rays have served as a cornerstone of dentistry. Dental radiographic imaging technologies have constantly improved, however, detecting occlusal lesions remains as one of the greatest challenges due to the low sensitivity of radiographs and the overlap of enamel. Once detected, occlusal lesions have penetrated far into the dentin, necessitating invasive restorative treatment. The adoption of near-infrared (NIR) systems in dentistry introduces the potential for early detection of occlusal lesions. Commercially available NIR systems for intra-oral applications currently operate near 800-nm; however, extrinsic stains may interfere with the detection of demineralization of the underlying enamel surface. Higher wavelengths such as 1300-nm render stains nearly transparent and enhances the contrast of sound enamel to demineralized enamel. This novel finding promotes minimally invasive dentistry and allows oral health professionals the ability to detect, image, track, and monitor early lesions without repeated exposure to ionizing radiation nor invasive treatment.

  14. Computerized classification of proximal occlusion in the left anterior descending coronary artery.

    PubMed

    Gregg, Richard E; Nikus, Kjell C; Zhou, Sophia H; Startt Selvester, Ronald H; Barbara, Victoria

    2010-01-01

    Proximal occlusion within the left anterior descending (LAD) coronary artery in patients with acute myocardial infarction leads to higher mortality than does nonproximal occlusion. We evaluated an automated program to detect proximal LAD occlusion. All patients with suspected acute coronary syndrome (n = 7,710) presenting consecutively to the emergency department of a local hospital with a coronary angiogram–confirmed flow-limiting lesion and notation of occlusion site were included in the study (n = 711). Electrocardiograms (ECGs) that met ST-segment elevation myocardial infarction (STEMI) criteria were included in the training set (n = 183). Paired angiographic location of proximal LAD and ECGs with ST elevation in the anterolateral region were used for the computer program development (n = 36). The test set was based on ECG criteria for anterolateral STEMI only without angiographic reports (n = 162). Tested against 2 expert cardiologists' agreed reading of proximal LAD occlusion, the algorithm has a sensitivity of 95% and a specificity of 82%. The algorithm is designed to have high sensitivity rather than high specificity for the purpose of not missing any proximal LAD in the STEMI population. Our preliminary evaluation suggests that the algorithm can detect proximal LAD occlusion as an additional interpretation to STEMI detection with similar accuracy as cardiologist readers.

  15. Electric current-producing device having sulfone-based electrolyte

    DOEpatents

    Angell, Charles Austen; Sun, Xiao-Guang

    2010-11-16

    Electrolytic solvents and applications of such solvents including electric current-producing devices. For example, a solvent can include a sulfone compound of R1--SO2--R2, with R1 being an alkyl group and R2 a partially oxygenated alkyl group, to exhibit high chemical and thermal stability and high oxidation resistance. For another example, a battery can include, between an anode and a cathode, an electrolyte which includes ionic electrolyte salts and a non-aqueous electrolyte solvent which includes a non-symmetrical, non-cyclic sulfone. The sulfone has a formula of R1--SO2--R2, wherein R1 is a linear or branched alkyl or partially or fully fluorinated linear or branched alkyl group having 1 to 7 carbon atoms, and R2 is a linear or branched or partially or fully fluorinated linear or branched oxygen containing alkyl group having 1 to 7 carbon atoms. The electrolyte can include an electrolyte co-solvent and an electrolyte additive for protective layer formation.

  16. Method and system for reducing device performance degradation of organic devices

    DOEpatents

    Teague, Lucile C.

    2014-09-02

    Methods and systems for reducing the deleterious effects of gate bias stress on the drain current of an organic device, such as an organic thin film transistor, are provided. In a particular aspect, the organic layer of an organic device is illuminated with light having characteristics selected to reduce the gate bias voltage effects on the drain current of the organic device. For instance, the wavelength and intensity of the light are selected to provide a desired recovery of drain current of the organic device. If the characteristics of the light are appropriately matched to the organic device, recovery of the deleterious effects caused by gate bias voltage stress effects on the drain current of the organic device can be achieved. In a particular aspect, the organic device is selectively illuminated with light to operate the organic device in multiple modes of operation.

  17. Device characterization and optimization of small molecule organic solar cells assisted by modelling simulation of the current-voltage characteristics.

    PubMed

    Zuo, Yi; Wan, Xiangjian; Long, Guankui; Kan, Bin; Ni, Wang; Zhang, Hongtao; Chen, Yongsheng

    2015-07-15

    In order to understand the photovoltaic performance differences between the recently reported DR3TBTT-HD and DR3TBDT2T based solar cells, a modified two-diode model with Hecht equation was built to simulate the corresponding current-voltage characteristics. The simulation results reveal that the poor device performance of the DR3TBDTT-HD based device mainly originated from its insufficient charge transport ability, where an average current of 5.79 mA cm(-2) was lost through this pathway at the maximum power point for the DR3TBDTT-HD device, nearly three times as large as that of the DR3TBDT2T based device under the same device fabrication conditions. The morphology studies support these simulation results, in which both Raman and 2D-GIXD data reveal that DR3TBTT-HD based blend films exhibit lower crystallinity. Spin coating at low temperature was used to increase the crystallinity of DR3TBDTT-HD based blend films, and the average current loss through insufficient charge transport at maximum power point was suppressed to 2.08 mA cm(-2). As a result, the average experimental power conversion efficiency of DR3TBDTT-HD based solar cells increased by over 40%.

  18. The impact of occlusal plane cant along with gingival display on smile attractiveness.

    PubMed

    Kaya, B; Uyar, R

    2016-05-01

    To evaluate the influence of occlusal plane cant in conjunction with maxillary gingival display on perception of smile attractiveness by orthodontists, dentists, and laypersons. Faculty of Dentistry at Baskent University. A total of 204 raters for smile attractiveness. A frontal intra-oral photograph of aligned teeth was modified using image processing software. Six different occlusal lines representing 0° to 5° cants were obtained by tilting the photographs. Each occlusal cant was adjusted in five manners resulting in five different gingival display amounts. Attractiveness of the 30 different smiles was evaluated by 204 raters divided into three groups (n = 68 in each group). Both occlusal cant (p < 0.001) and gingival display amount (p < 0.001) had a statistically significant influence on smile attractiveness. Smile attractiveness scores with reference to amount of gingival display showed a significant difference between rater groups (p < 0.001). Orthodontists preferred 1-mm coverage of upper central incisors by the upper lip, whereas dentists and laypersons preferred 2 mm. Significant (p < 0.001) interaction was observed between occlusal cant and gingival display amount, which influenced smile attractiveness. Increase in both occlusal plane cant and gingival display negatively influences smile attractiveness. The influence of occlusal plane cant becomes less when gingival display increases, whereas the influence of gingival display decreases when occlusal cant increases. Dentists are more generous than orthodontists, while laypersons are the most generous regarding smile attractiveness scores. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. [Integrated therapeutic strategy in large bowel neoplastic occlusion. An innovative therapeutic protocol].

    PubMed

    Gattai, Riccardo; Mascitelli, Erminia Macera; Bechi, Paolo; Pace, Marcello

    2007-01-01

    Occlusive complication is a common event in the colo-rectal cancer (20-30% of cases). Operative mortality and 5 yrs survival of not occlusive cancer vs occlusive cancer is 11% vs 23% and 45% vs 25% rispectively. In occlusive cancer the level of parietal infiltration affects considerably the local and peritoneal recurrence. 50% of all patients underwent a surgical re-operation for colo-rectal cancer have peritoneal neoplastic implant. The resolution of occlusive complication in immediate or delayed urgency with decompressive derivation, it allows to perform an integrated treatment of choice that it could guarantee the oncological radical procedure. RATIONALE-METHODS: The intraperitoneal hyperthermic chemotherapy (IPHC) combined with radical or cytoriductive surgery performs its action through sinergistic effects of high dosage and concentration of drugs and hyperthermia. These agents perform a cell killing with a direct contact against micro and/or macroscopic neoplastic residue. In radical surgery with curative intent, the association with IPHC ("preventive" adjuvant) has got as objective the distruction of microscopic local or peritoneal metastasis. In occlusive cancer with synchronous or metachronous peritoneal carcinomatosis, the performance of the cytoreductive surgery with IPHC ("therapeutic" adjuvant) is the only treatment that improves the survival and the quality of remainig life. The clinical results reported by many Istitutions indicates that the 2-5 yrs survivals are 45-60% and 20-30% rispectively. These data lead us to believe that an optimal eradication of micro and/or macroscopic peritoneal spreading could be optained also in occlusive colo-rectal cancer.

  20. Ventilation Increases with Lower Extremity Venous Occlusion in Young Adults

    PubMed Central

    Keller-Ross, Manda L.; Cowl, Andrielle L.; Cross, Troy; Johnson, Bruce D.; Olson, Thomas P.

    2015-01-01

    Introduction Venous distention via sub-systolic occlusion of the lower limbs may augment ventilation via stimulation of group III/IV afferent neurons. Purpose The purpose of this study was to examine the ventilatory response to graded lower extremity venous occlusion during exercise in healthy adults. Methods Nineteen adults (9 men, 25±5 yr) completed two visits. Visit 1: a maximal cycle ergometry exercise test. Visit 2 included a 30% peak workload cycle exercise with randomized inflations of bilateral thigh pressure tourniquets to 20, 40, 60, 80, 100 mmHg for 2 min each, separated by 2 min of deflation. Three min of cycling occurred prior to cuffing (CTL). Expired minute ventilation (VE), whole body gas exchange, rating of perceived exertion and dyspnea were measured during each session. Results VE increased significantly from the control condition (exercise only, control, CTL) to each occlusion pressure (p<0.05) with the greatest increase at 100 mmHg (CTL to 100 mmHg: 31.5±6.6 to 40.1±10.7 L/min). Respiratory rate (RR) increased as well (CTL to 100 mmHg: 24.8±6.0 to 30.9±11.5 breaths/min, p<0.05, condition effect) with no change in tidal volume (p>0.05). Tidal volume to inspiratory time (VT/TI) increased significantly from the CTL condition to each occlusion pressure (CTL to 100 mmHg: 1.5±0.3 to 1.8±0.4 L/min, p<0.05, all pressures). Dyspnea and RPE increased with all occlusion pressures from CTL exercise (p<0.05, all pressures). Conclusion Our findings suggest that mild-to-moderate venous occlusion of the lower extremity evokes a tachypneic breathing pattern which, in turn, augments VE and perceived breathing effort during exercise. PMID:26484951

  1. Neural substrates of dynamic object occlusion.

    PubMed

    Shuwairi, Sarah M; Curtis, Clayton E; Johnson, Scott P

    2007-08-01

    In everyday environments, objects frequently go out of sight as they move and our view of them becomes obstructed by nearer objects, yet we perceive these objects as continuous and enduring entities. Here, we used functional magnetic resonance imaging with an attentive tracking paradigm to clarify the nature of perceptual and cognitive mechanisms subserving this ability to fill in the gaps in perception of dynamic object occlusion. Imaging data revealed distinct regions of cortex showing increased activity during periods of occlusion relative to full visibility. These regions may support active maintenance of a representation of the target's spatiotemporal properties ensuring that the object is perceived as a persisting entity when occluded. Our findings may shed light on the neural substrates involved in object tracking that give rise to the phenomenon of object permanence.

  2. Occlusion pressures in men rebreathing CO2 under methoxyflurane anesthesia.

    PubMed

    Derenne, J P; Couture, J; Iscoe, S; Whitelaw, A; Milic-Emili, J

    1976-05-01

    The effect of general anesthesia on control of breathing was studied by CO2 rebreathing and occlusion pressure measurements in six normal human subjects under methoxyflurane anesthesia. CO2 was found to increase the amplitude of the occlusion pressure wave without changing its shape, so that CO2 responses in terms of the occlusion pressure developed 100 ms after the onset of inspiration (Po/0.1) gave results equivalent to the responses in terms of Po/1.o or any other parameter of the pressure wave. Methoxyflurane depressed the ventilatory response to CO2 but not the occlusion pressure response, implying that the most important action of the anesthetic was to increase the effective elastance of the respiratory system rather than to depress the respiratory centers. The elastance was further increased by CO2, and this mechanical change had the effect of shifting the "apneic threshold" extrapolated from the ventilatory response curve to a lower PAco2. Frequency of breathing, inspiratory and expiratory times were not altered by CO2 in anesthetized subjects.

  3. [A cephalometric study on determining the orientation of occlusal plane].

    PubMed

    Xie, J; Zhao, Y; Chao, Y; Luo, W

    1993-12-01

    A study of the parallel relationship between the occlusal plane and the line connecting nasal alar and tragus was made in 90 dentulous cases by using cephalometry. The results show that the line connecting the inferior point of nasal alar and the mid-point of tragus runs much more parallel with the occlusal plane. The regression equation reveals a "line of closest fitting". It was used in the prosthetic treatment for 50 edentulous patients with good clinical results. The line connecting the inferior point of nasal alar and the mid-point of tragus therefore represents a proper reference plane for determining occlusal plane and hence should be still a valuable index in clinical dentistry.

  4. The ``Leakage Current Sentinel'': A novel plug-in socket device for online biomedical equipment electrical safety surveillance

    NASA Astrophysics Data System (ADS)

    Cappa, Paolo; Marinozzi, Franco; Sciuto, Salvatore Andrea

    2000-07-01

    The Leakage Current Sentinel (LCS) has been designed and implemented for the detection of hazardous situations caused by dangerous earth leakage current values in intensive care units and operating theaters. The device, designed and manufactured with full compliance of the high risk environment requirements, is able to monitor online the earth leakage current and detect ground wire faults. Operation utilizes a microammeter with an overall sensitivity of 2.5×104 V/A. In order to assure the reliability of the device in providing alarm signals, the simultaneous presence of absorbed power current is monitored by means of another ammeter with decreased sensitivity (3.0 V/A). The measured root mean square current values are compared with reference values in order to send signals to NAND and OR complementary metal-oxide-semiconductor gates to enable audible and visible alarms according to the possible hazardous cases examined in the article. The final LCS packaging was shaped as a wall socket adapter for common electromedical device power cord plugs, with particular attention to minimizing its dimensions and to provide analog voltage outputs for both measured leakage and power currents, in order to allow automatic data acquisition and computerized hazardous situation management. Finally, a personal computer based automatic measuring system has been configured to simultaneously monitor several LCSs installed in the same intensive care unit room and, as a consequence, to distinguish different hazardous scenarios and provide an adequate alert to the clinical personnel whose final decision is still required. The test results confirm the effectiveness and reliability of the LCS in giving an alert in case of leakage current anomalous values, either in case of a ground fault or in case of a dangerous leakage current.

  5. Procedural and longer-term outcomes of wire- versus device-based antegrade dissection and re-entry techniques for the percutaneous revascularization of coronary chronic total occlusions.

    PubMed

    Azzalini, Lorenzo; Dautov, Rustem; Brilakis, Emmanouil S; Ojeda, Soledad; Benincasa, Susanna; Bellini, Barbara; Karatasakis, Aris; Chavarría, Jorge; Rangan, Bavana V; Pan, Manuel; Carlino, Mauro; Colombo, Antonio; Rinfret, Stéphane

    2017-03-15

    There are few data regarding the procedural and follow-up outcomes of different antegrade dissection/re-entry (ADR) techniques for chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We compiled a multicenter registry of consecutive patients undergoing ADR-based CTO PCI at four high-volume specialized institutions. Patients were divided according to the specific ADR technique used: subintimal tracking and re-entry (STAR), limited antegrade subintimal tracking (LAST), or device-based with the CrossBoss/Stingray system (Boston Scientific, Marlborough, MA). Major adverse cardiac events (MACE: cardiac death, target-vessel myocardial infarction and target-vessel revascularization) on follow-up were the main outcome of this study. Independent predictors of MACE were sought with Cox regression analysis. A total of 223 patients were included (STAR n=39, LAST n=68, CrossBoss/Stingray n=116). Baseline characteristics were similar across groups. Technical and procedural success was lower with STAR (59% and 59%), as compared with LAST (96% and 96%) and CrossBoss/Stingray (89% and 87%; p<0.001 for both). At 24-month follow-up, MACE rates were higher in STAR (15.4%) and LAST (17.5%), as compared with device-based ADR with CrossBoss/Stingray (4.3%, p=0.02), driven by TVR (7.7% vs. 15.5% vs. 3.1%, respectively; p=0.02). Multivariable Cox regression analysis identified wire-based ADR (STAR and LAST) and total stent length as independent predictors of MACE. In this multicenter cohort of patients undergoing CTO PCI with ADR techniques, STAR had lower success rates, as compared with the CrossBoss/Stingray system and LAST. The CrossBoss/Stingray system was independently associated with lower risk of MACE on follow-up, as compared with wire-based ADR techniques. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Investigation of disorder and its effect on electrical transport in electrochemically doped polymer devices by current-voltage and impedance spectroscopy

    NASA Astrophysics Data System (ADS)

    Rahman Khan, Motiur; Anjaneyulu, P.; Koteswara Rao, K. S. R.; Menon, R.

    2017-03-01

    We report on the analysis of temperature-dependent current-voltage characteristics and impedance measurements of electrochemically doped poly(3-methylthiophene) devices at different doping levels. The extent of doping is carefully tailored such that only the bulk-limited transport mechanism prevails. A transition from exponentially distributed trap-limited transport to trap-free space-charge-limited current is observed in current-voltage conduction upon increasing the doping. The obtained trap densities (3.2  ×  1016 cm-3 and 8.6  ×  1015 cm-3) and trap energies (31.7 meV and 16.6 meV) for different devices signify the variation in disorder with doping, which is later supported by impedance measurements. Impedance-frequency data for various devices can not be explained using the parallel resistance-capacitance (RC) model in the equivalent circuit. However, this was established by incorporating a constant phase element Q (CPE) instead of the capacitance parameter. It should be emphasized that low doping devices in particular are best simulated with two CPE elements, while the data related to other devices are fitted well with a single CPE element. It is also observed from evaluated circuit parameters that the spatial inhomogeneity and disorder are the cause of variability in different samples, which has an excellent correlation with the temperature-dependent current-voltage characteristics.

  7. Liver size, bodyweight, and tolerance to acute complete occlusion of congenital extrahepatic portosystemic shunts in dogs.

    PubMed

    Doran, Ivan P; Barr, Frances J; Hotston Moore, Alasdair; Knowles, Toby G; Holt, Peter E

    2008-10-01

    To investigate the relationship between preoperative liver size, bodyweight, and tolerance to shunt occlusion in dogs with congenital extrahepatic portosystemic shunt(s) (CPSS). Longitudinal cohort study. Dogs with CPSS (n=35). Ultrasonography was used to measure preoperative maximum transverse dimension of the liver (TS) of each dog. Intraoperative portal pressures were measured, before and after CPSS occlusion, via a jejunal vein catheter. Tolerance to shunt occlusion was judged on gross visceral observations, and on changes in portal pressure, central venous and mean arterial pressures. TS was significantly related to bodyweight (P<.05). Mean ratios for TS/bodyweight were calculated for dogs tolerant and intolerant of acute complete shunt occlusion. Dogs tolerant to occlusion had significantly higher TS/bodyweight ratios than dogs intolerant to occlusion (P=.025). Dogs with a TS/bodyweight ratio of >7 were more likely to tolerate CPSS occlusion than dogs with a TS/bodyweight ratio of <5 (P=.036). A model was generated to predict portal pressure rise after shunt occlusion, based on liver dimensions and bodyweight (R=0.668). Intestinal oxygenation did not correlate significantly with tolerance to CPSS occlusion (P=.29). In dogs with CPSS, liver size (relative to bodyweight) is significantly greater (P=.025) in dogs that are tolerant of full ligation than intolerant of occlusion. Preoperative measurement of bodyweight and liver size help indicate the likelihood of tolerance to acute complete occlusion of CPSS in dogs.

  8. Initial Experience and Feasibility of the New Low-Profile Stingray Catheter as Part of the Antegrade Dissection and Re-Entry Revascularization Strategy for Coronary Chronic Total Occlusions

    PubMed Central

    Maeremans, Joren; Palmers, Pieter-Jan; Dens, Joseph

    2017-01-01

    Case series Patient: Male, 77 • Male, 57 • Male, 73 Final Diagnosis: Coronary chronic total occlusion Symptoms: Angina pectoris Medication: — Clinical Procedure: Percutaneous coronary intervention of coronary chronic total occlusions Specialty: Cardiology Objective: Unusual setting of medical care Background: During antegrade dissection re-entry (ADR) of chronic total occlusions (CTO), the first-generation Stingray catheter requires the use of large-bore guides (sheathless 7.5 Fr or 8 Fr), which increases the risk for access site-related complications and compromises radial approaches. Smaller guiding sizes necessitate long guidewires (e.g., 300 cm) or guidewire extensions for catheter advancement or removal. However, friction between guides and the Stingray catheter can result in unstable guidewire position or unintentional removal. Furthermore, failure to deliver the catheter at the distal re-entry zone is a common problem. To overcome issues of deliverability and reduce the need for pre-dilatations, with its inherent risk of creating subintimal hematomas, the Stingray low-profile (LP) balloon catheter was developed. Case Report: We describe 3 cases of successful application of the novel Stingray LP catheter during ADR. In all cases, 7 Fr guiding catheters were successfully used in combination with the device. The lower profile facilitated a good exchange and delivery of the device, without the need for balloon pre-dilatations in 2 cases. This resulted in a limited subintimal plane, enabling a smooth puncture into the true lumen. One case presented with extreme levels of calcification and tortuosity, resulting in a high degree of friction, despite the lower catheter profile. No in-hospital coronary or access site-related complications occurred. Conclusions: This case report illustrates the feasibility of the Stingray LP catheter for the treatment of CTOs via the ADR technique. The lower profile of the catheter potentially increases the deliverability

  9. Occlusal plane rotation: aesthetic enhancement in mandibular micrognathia.

    PubMed

    Rosen, H M

    1993-06-01

    Patients afflicted with extreme degrees of mandibular micrognathia typically have vertically deficient rami as well as sagittally deficient mandibular bodies. This results in deficient posterior facial height, an obtuse gonial angle, excessively steep occlusal and mandibular planes, and a compensatory increase in anterior facial height. The entire maxillomandibular complex is overrotated in a clockwise direction. Standard orthognathic surgical correction fails to address this rotational deformity. As a consequence, the achieved projection of the lower face is inadequate, posterior facial height is further reduced, and occlusal and mandibular planes remain steep. Eleven patients with severe mandibular micrognathia underwent a surgical correction involving occlusal plane rotation to its normal orientation relative to Frankfort horizontal. This was accomplished by Le Fort I osteotomy to shorten the anterior maxilla (creating open bites in seven patients and making preexisting open bites worse in four patients) and sagittal split ramus osteotomies to advance and rotate the mandibular body counterclockwise, thus closing the surgically produced open bite. Counterclockwise rotation of the mandible afforded significantly greater sagittal displacement at the B point (mean 17 mm) than at the first molar (mean 10 mm) and produced adequate degrees of projection of the lower face when accompanied by a modest sliding genioplasty (mean 6.9 mm). Total advancement at the pogonion was a mean of 25.2 mm. In addition, posterior facial height was preserved, and mandibular and occlusal planes were normalized to mean angles of 27 and 10 degrees, respectively. At follow-up, which ranged from 9 to 24 months with a mean of 14.1 months, the mean sagittal relapse at the B point was 1.9 mm. Although heretofore considered unstable and therefore not clinically accepted, maxillomandibular counterclockwise rotation to normalize the occlusal plane rotational deformity provides stable, aesthetically

  10. Patching compliance with full-time vs. part-time occlusion therapy.

    PubMed

    Kane, Jessica; Biernacki, Ron; Fraine, Lisa; Fukuda, Neva; Haskins, Kelsie; Morrison, David G

    2013-01-01

    Amblyopia is commonly treated with part-time occlusion (PTO) therapy. We have made two anecdotal observations regarding this therapy. First, children undergoing full-time occlusion seem to have better success and compliance rates. Secondly, a subset of children exists that fail PTO but can improve with more aggressive therapy. A retrospective review where treatment, visual outcome, and compliance scores were recorded. Compliance was graded on percent adherence reported by family. Patients scored “1” (for no compliance), “2” (for 1–25% of prescribed treatment performed), “3” (for 26–50%), “4” (for 51–75%), or “5” (for 76–100%). Seventy-six children were enrolled in the study: forty-five were treated with part-time occlusion, twenty-two were treated with full time occlusion (FTO), and nine had a history of failed PTO and were subsequently treated with FTO. Visual outcomes for FTO versus PTO were not statistically significant (P = 0.82). However, compliance rates in FTO were significantly better (P = 0.02). Of the nine patients that failed PTO, four improved an average of three lines with full-time occlusion, and five had no change with more aggressive patching. This study confirms previous reports of similar visual outcomes between PTO and FTO. However, compliance rates for FTO seem to be higher and some children who have failed PTO may improve with FTO.

  11. Vascular occlusion and infarction in sickle cell crisis and the sickle chest syndrome.

    PubMed Central

    Athanasou, N A; Hatton, C; McGee, J O; Weatherall, D J

    1985-01-01

    A young adult with homozygous sickle cell anaemia (Hb SS) suffered a fatal sickle cell crisis complicated by the sickle chest syndrome. At necropsy multiple large infarcts of the lung, bone marrow, and pituitary gland were found. The large majority of pulmonary infarcts were not associated with either gross or microscopic vaso-occlusion. These findings are discussed and correlated with past and current opinions of sickle cell crisis and the sickle chest syndrome. Images PMID:4008666

  12. In vivo THz imaging of human skin: Accounting for occlusion effects.

    PubMed

    Sun, Qiushuo; Parrott, Edward P J; He, Yuezhi; Pickwell-MacPherson, Emma

    2018-02-01

    In vivo terahertz (THz) imaging of human skin needs to be done in reflection geometry due to the high attenuation of THz light by water in the skin. To aid the measurement procedure, there is typically an imaging window onto which the patient places the area of interest. The window enables better pulse alignment and helps keep the patient correctly positioned during the measurement. In this paper, we demonstrate how the occlusion caused by the skin contact with the imaging window during the measurement affects the THz response. By studying both rapid point measurements and imaging over an area of a human volar forearm, we find that even 5 seconds of occlusion affects the THz response. As the occlusion time increases, the skin surface water content increases, resulting in the reduction of the amplitude of the reflected THz pulse, especially in the first 3 minutes. Furthermore, it was found that the refractive index of the volar forearm increased by 10% to 15% after 20 minutes of occlusion. In this work, we examine and propose a model for the occlusion effects due to the quartz window with a view to compensating for its influence. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Temporary Arterial Balloon Occlusion as an Adjunct to Yttrium-90 Radioembolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Nambiar, Ashwin, E-mail: uvashwin@gmail.com; Hagspiel, Lauren M., E-mail: lmh4gg@virginia.edu

    2013-06-15

    Purpose. This study was designed to describe the technique of arterial occlusion using a temporary occlusion balloon system as an alternative to coil occlusion during Yttrium-90 radioembolization of hepatic tumors. Methods. Review of charts, angiography, and follow-up imaging studies of consecutive patients undergoing oncological embolization procedures in which a HyperForm system (ev3 Neurovascular, Irvine, CA) was used. Intraprocedural target vessel occlusion and patency of the target vessel on follow-up were recorded. Clinical data and Bremsstrahlung scans were reviewed for evidence of nontarget embolization. Results. Four radioembolization procedures were performed in three patients (all female, age 48-54 (mean 52) years). Fivemore » arteries were temporarily occluded (three gastroduodenal arteries, one right gastric artery, and one cystic artery). All radioembolization procedures were successfully completed. Follow-up imaging (either digital subtraction angiography (DSA) or computed tomography angiography (CTA)) was available for all patients between 28-454 (mean 183) days following the procedure, demonstrating all five vessels to be patent. No clinical or imaging evidence for nontarget embolization was found. Conclusions. Temporary balloon occlusion of small and medium-sized arteries during radioembolization allows safe therapy with preserved postprocedural vessel patency on early and midterm follow-up.« less

  14. Efficacy of Selective Grinding Guided by an Occlusal Splint in Management of Myofascial Pain: A Prospective Clinical Trial

    PubMed Central

    Fernández-González, Felipe J.; Cabero-López, Jorge; Brizuela, Aritza; Suazo, Ivan; Pérez-Pevida, Esteban; Cobo, Teresa; Montalban, Oier; Diéguez-Pereira, Markel; Chávarri-Prado, David; de la Pinta, Iker Bellanco; Jiménez-Garrudo, Antonio

    2017-01-01

    Background: For patients whose centric relation (CR) has not been considered at the start and during treatment, the task of achieving an occlusal scheme that works together with the temporomandibular joint, the muscles, and the structures of the stomatognathic apparatus becomes a major concern. Objective: This study aims to describe a reproducible, predictable and to date unreported procedure of selective grinding guided by an occlusal splint and to analyze condylar position (CP) based on the skeletal pattern. Methods: A total of 72 symptomatic patients (38 females and 34 males) were classified into three groups: hyperdivergent, intermediate and hypodivergent. CP was quantified by mounted casts on a measures condyle displacement (MCD) device. Helkimo index was also performed in order to assess the severity of the temporomandibular joint (TMJ) disorders attending to clinical dysfunction, occlusal state and anamnestic dysfunction. Once the stability had been obtained, the splint was progressively reduced until the maximum intercuspation (MIC) was achieved. Results: The vertical displacement was found to be significantly different between the hyperdivergent and other two groups (p<0.01). Comparisons of MCD analysis before and after the selective grinding procedure identified a statistically significant difference in the horizontal and vertical CP (p<0.01) between the different groups whereas the Helkimo Index showed a clear improvement of TMJ disorders. Conclusion: All facial types, specially the hyperdivergent face type, showed a reduction in condylar displacement (CD) and less craniomandibular symptoms using this procedure, making it an excellent technique for clinicians. PMID:28839479

  15. Evaluation of in-vehicle HMI using occlusion techniques: experimental results and practical implications.

    PubMed

    Baumann, Martin; Keinath, Andreas; Krems, Josef F; Bengler, Klaus

    2004-05-01

    Despite the usefulness of new on-board information systems one has to be concerned about the potential distraction effects that they impose on the driver. Therefore, methods and procedures are necessary to assess the visual demand that is connected to the usage of an on-board system. The occlusion-method is considered a strong candidate as a procedure for evaluating display designs with regard to their visual demand. This paper reports results from two experimental studies conducted to further evaluate this method. In the first study, performance in using an in-car navigation system was measured under three conditions: static (parking lot), occlusion (shutter glasses), and driving. The results show that the occlusion-procedure can be used to simulate visual requirements of real traffic conditions. In a second study the occlusion method was compared to a global evaluation criterion based on the total task time. It can be demonstrated that the occlusion method can identify tasks which meet this criterion, but are yet irresolvable under driving conditions. It is concluded that the occlusion technique seems to be a reliable and valid method for evaluating visual and dialogue aspects of in-car information systems.

  16. Mechanical Performance of Two Left Atrial Appendage Occlusion Systems: In Vitro Comparison of Tug Force, Radial Force, Sealing and Deformation.

    PubMed

    Menne, Matthias F; Schrickel, Jan W; Nickenig, Georg; Al-Kassou, Baravan; Nelles, Dominik; Schmitz-Rode, Thomas; Steinseifer, Ulrich; Sedaghat, Alexander

    2018-05-24

    The aim of this study was to establish in vitro bench-tests of left atrial appendage occlusion (LAAo) devices regarding tug force, radial force and sealing capacity. Two LAAo devices, namely the WATCHMAN™ and the Occlutech ® , of three different sizes underwent testing in novel dedicated in vitro setups. Radial force was assessed in a commercial radial force tester. At baseline, tug force of the WATCHMAN™ was significantly higher when compared to Occlutech ® for all devices. Repeated resheathing resulted in a reduction of device-diameter in the WATCHMAN™ devices of max. 7.9%, whereas diameters of Occlutech ® occluders remained unchanged. Tug force was not significantly impacted by resheathing in both devices. At baseline, sealing capacity in a bench-test using silicone LAA-models did not differ between the devices. Resheathing lead to an in vitro loss of sealing capacity of the WATCHMAN™ devices, increasing with resheathing and resulting in a max. peridevice leak of 91.1 ± 7.9%. Radial force was higher for the Occlutech ® devices and decreased for WATCHMAN™ occluders after resheathing. The WATCHMAN™ occluder series showed progressive deformation, increased peridevice leakage and decreased radial force after resheathing, presumably as a result of diameter reduction. Tug force of the WATCHMAN™ was not impaired by resheathing and was significantly higher than that of the Occlutech ® device.

  17. Multi-step resistive switching behavior of Li-doped ZnO resistance random access memory device controlled by compliance current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Chun-Cheng; Department of Mathematic and Physical Sciences, R.O.C. Air Force Academy, Kaohsiung 820, Taiwan; Tang, Jian-Fu

    2016-06-28

    The multi-step resistive switching (RS) behavior of a unipolar Pt/Li{sub 0.06}Zn{sub 0.94}O/Pt resistive random access memory (RRAM) device is investigated. It is found that the RRAM device exhibits normal, 2-, 3-, and 4-step RESET behaviors under different compliance currents. The transport mechanism within the device is investigated by means of current-voltage curves, in-situ transmission electron microscopy, and electrochemical impedance spectroscopy. It is shown that the ion transport mechanism is dominated by Ohmic behavior under low electric fields and the Poole-Frenkel emission effect (normal RS behavior) or Li{sup +} ion diffusion (2-, 3-, and 4-step RESET behaviors) under high electric fields.

  18. A Plasma Focus Device with a 2-MA Discharge Current as a Hard X-Ray Source

    NASA Astrophysics Data System (ADS)

    Yurkov, D. I.; Dulatov, A. K.; Lemeshko, B. D.; Andreev, D. A.; Golikov, A. V.; Mikhailov, Yu. V.; Prokuratov, I. A.; Selifanov, A. N.; Fatiev, T. S.

    2018-04-01

    A device based on a pulsed current generator with capacitive energy storage loaded on a plasma focus (PF) chamber is described. The device provides a discharge current amplitude of up to 2 MA in the PF chamber at a stored energy in the capacitor bank of up to 150 kJ. The PF chamber is designed to study hard X-ray (HXR) emission. It has windows for output of HXR emission in the cathode direction, as well as a special insert for output of HXR emission into the anode cavity. A study of operation of the chamber as a part of the setup with the use of various X-ray targets on the anode has been carried out. At a discharge current of 1.5MA, an HXR pulse with an average duration of 16 ns and energy spectrum from 10 to 200 keV, which provides an absorbed dose in the irradiated samples on the order of 1 Sv, is generated in the PF chamber.

  19. Comparative study to evaluate the accuracy of polyether occlusal bite registration material and occlusal registration wax as a guide for occlusal reduction during tooth preparation.

    PubMed

    Joshi, Niranjan; Shetty, Sridhar N; Prasad, Krishna D

    2013-01-01

    The use of different materials and techniques has been studied to decide the safest quantum of reduction of the occlusal surfaces. However, these methods provide limited information as to the actual amount of reduction with limitations in accuracy, accessibility and complexity. The objective of this study was to compare and evaluate the reliability of the most commonly used occlusal registration wax that with polyether bite registration material as a guide for occlusal reduction required during tooth preparations. For the purpose of this study, 25 abutment teeth requiring tooth preparation for fixed prosthesis were selected and tooth preparations carried out. Modeling wax strips of specific dimensions were placed onto the cast of prepared tooth, which was mounted on maximum intercuspation on the articulator and the articulator was closed. The thickness of the wax registration was measured at three zones namely two functional cusps and central fossa. Similar measurements were made using the polyether bite registration material and prosthesis at the same zones. The data was tabulated and was subjected to statistical analysis using anova test and Tukey honestly significant difference test. The differences in thickness between wax record and prosthesis by 0.1346 mm, whereas the difference between polyether and prosthesis was 0.02 mm with a P value of 0.042, which is statistically significant. This means that the wax record was 8.25% larger than the prosthesis while polyether was just 1.27% larger than the prosthesis. The clinical significance of the above analysis is that Ramitec polyether bite registration material is most suitable material when compared with commonly used modeling wax during the tooth preparation.

  20. Rf-assisted current startup in the Fusion Engineering Device (FED)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borowski, S.K.; Peng, Y.K.M.; Kammash, T.

    1982-08-01

    Auxiliary rf heating of electrons before and during the current rise phase in the Fusion Engineering Device is examined as a means of reducing both the initiation loop voltage and resistive flux expenditure during startup. Prior to current initiation 1 to 2 MW of electron cyclotron resonance heating (ECRH) power at approx. 90 GHz is used to create a small volume of high conductivity plasma (T/sub e/ approx. = 100 eV, n/sub e/ approx. = 10/sup 13/ cm/sup -3/) near the upper hybrid resonance (UHR) region. This plasma conditioning permits a small radius (a/sub o/ approx. = 0.2 to 0.4more » m) current channel to be established with a relatively low initial loop voltage (less than or equal to 25 V). During the subsequent plasma expansion and current ramp phase, additional rf power is introduced to reduce volt-second consumption due to plasma resistance. A near classical particle and energy transport model has been developed to estimate the efficiency of electron heating in a currentless toroidal plasma. The model assumes that preferential electron heating at the UHR leads to the formation of an ambipolar sheath potential between the neutral plasma and the conducting vacuum vessel and limiter. The ambipolar electric field (E/sub AMB/) enables the plasma to neutralize itself via poloidal E vector/sub AMB/ x B vector drift. This form of effective rotational transform short-circuits the vertical charge separation and improves particle confinement.« less

  1. CIRSE Vascular Closure Device Registry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl; Mueller-Huelsbeck, Stefan; Libicher, Martin

    2011-02-15

    Purpose: Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods: The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results: Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0-14.5] for antegrade access and 1.8% (95% CI 1.1-2.9) for retrograde access (Pmore » = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only <0.5% of patients. Postdeployment bleeding occurred in 6.4%, and most these (51.5%) could be managed with light manual compression. During follow-up, other device-related complications were reported in 1.3%: seven false aneurysms, three hematoma >5.9 cm, and two vessel occlusions. Conclusion: The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters.« less

  2. CIRSE Vascular Closure Device Registry

    PubMed Central

    Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2010-01-01

    Purpose Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. Methods The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. Results Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0–14.5] for antegrade access and 1.8% (95% CI 1.1–2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only <0.5% of patients. Postdeployment bleeding occurred in 6.4%, and most these (51.5%) could be managed with light manual compression. During follow-up, other device-related complications were reported in 1.3%: seven false aneurysms, three hematoma >5.9 cm, and two vessel occlusions. Conclusion The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters. PMID:20981425

  3. An Investigation of the Posterior Component of Occlusal Force

    DTIC Science & Technology

    1994-05-01

    of the hemostat allowed subjects to consistently orient the bite force transducer parallel to the occIusal plane , thus allowing the bite force to be...the anterior component of occlusal force was influenced by the steepness of the occlusal plane . Southard et al (1989) was the first to quantify the...young adult males yielded higher mean maximum bite forces at 20 mm opening and at 40 mm opening. The authors suggested that orientation and function of

  4. Dental Occlusion and Ophthalmology: A Literature Review

    PubMed Central

    Marchili, Nicola; Ortu, Eleonora; Pietropaoli, Davide; Cattaneo, Ruggero; Monaco, Annalisa

    2016-01-01

    Stomatognathic system is strictly correlated to other anatomical regions; many studies investigated relationship between temporomandibular joint and posture, several articles describe cranio-facial pain from dental causes, such as trigger points. Until now less interest has been given to connections between dental occlusion and ophthalmology, even if they are important and involving. Clinical experience in dental practice claims that mandibular latero-deviation is connected both to eye dominance and to defects of ocular convergence. The trigeminal nerve is the largest and most complex of the twelve cranial nerves. The trigeminal system represents the connection between somitic structures and those derived from the branchial arches, collecting the proprioception from both somitic structures and oculomotor muscles. The intermedius nucleus of the medulla is a small perihypoglossal brainstem nucleus, which acts to integrate information from the head and neck and relays it on to the nucleus of the solitary tract where autonomic responses are generated. This intriguing neurophysiological web led our research group to investigate anatomical and functional associations between dental occlusion and vision. In conclusion, nervous system and functional pathways strictly connect vision and dental occlusion, and in the future both dentists and oculists should be more and more aware of this correlation for a better diagnosis and therapy. PMID:27733873

  5. Sperm characteristics and teratology in rats following vas deferens occlusion with RISUG and its reversal.

    PubMed

    Lohiya, N K; Suthar, R; Khandelwal, A; Goyal, S; Ansari, A S; Manivannan, B

    2010-02-01

    The functional success of the reversal of vas occlusion by styrene maleic anhydride (RISUG), using the solvent vehicle, Dimethyl Sulphoxide (DMSO), has been investigated. Reversal with DMSO was carried out in Wistar albino rats 90 days after bilateral vas occlusion. The body weight, organ weight, sperm characteristics, fertility test and teratology, including skeletal morphology were evaluated in vas occlusion and reversal animals and in F(1) progenies to assess the functional success of the occlusion and reversal. Body weight, organ weight and the cauda epididymal sperm characteristics of vas occlusion and reversal animals and of F(1) progenies were comparable to control. Ejaculated spermatozoa in the vaginal smear showed detached head/tail, acrosomal damage, bent midpiece, bent tail and morphological aberrations in sperm head after vas occlusion, which returned to normal, 90 days after reversal. Monthly fertility test, post-injection showed 0% fertility, which improved gradually and 100% fertility was achieved 90 days after reversal. The fertility/pregnancy/implantation record and skeletal morphology of the offspring were comparable to control. The results suggest functional success and safety of vas occlusion reversal by DMSO.

  6. Occlusal characteristics of children with hypertrophied adenoids in Nigeria.

    PubMed

    Osiatuma, Vivien Ijeoma; Otuyemi, Olayinka Donald; Kolawole, Kikelomo Adebanke; Ogunbanjo, Babatunde Ogunbiyi; Amusa, Yemisi Bola

    2015-03-01

    Nasorespiratory function and its relation to craniofacial growth are of great interest because of the basic biological relationship between form and function, and the accumulating findings of the relationship between mode of breathing, craniofacial growth and orthodontic treatment. The aim of this study was to evaluate the effect of adenoid hypertrophy and sociodemographic variables on the occlusion of children. A total of 180 subjects aged 3-12 years were selected at the Obafemi Awolowo University Teaching Hospital Complex, Ile-Ife, Nigeria. Ninety subjects had hypertrophied adenoids while 90 normal children served as the control group. Orthodontic examinations were carried out and impressions for study models taken. Occlusion was assessed in the anterior-posterior, transverse and vertical planes. Class I relationship was the most prevalent occlusion in both adenoid and control subjects (55.6% and 72.2%, respectively). The occurrence of class II division 1 was significantly higher among adenoid than control subjects (P=0.003). Posterior crossbites occurred significantly more in adenoid subjects in the 9-12 years category. In the vertical plane, the occurrence of deep bite was significantly greater in male than female adenoid subjects. Age had a statistically significant but weak correlation with anterior open bite (r=0.37). Age and BMI also had significant though weak correlations with posterior crossbite in female adenoid subjects (r=0.39 and r=0.36, respectively). Regression analysis also showed that age had a significant effect on the occurrence of anterior open bite, while BMI had a significant effect on the occurrence of class II occlusion in adenoid subjects (P<0.05). The presence of hypertrophied adenoids affects the occlusion in the three planes. Age and BMI have significant effects on the occurrence of anterior open bite and class II division 1 malocclusion respectively in adenoid subjects. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. SWIR reflectance imaging of demineralization on the occlusal surfaces of teeth beyond 1700 nm

    NASA Astrophysics Data System (ADS)

    Ng, Chung; Simon, Jacob C.; Fried, Daniel; Darling, Cynthia L.

    2018-02-01

    Most new lesions are found in the pits and fissures of the occlusal surface. Radiographs have extremely low sensitivity for early occlusal decay and by the time the lesion is severe enough on a radiograph it typically has penetrated well into the dentin and surgical intervention is required. The occlusal surfaces are heavily stained and visual and tactile methods for their detection also have poor sensitivity and specificity. Previous studies at wavelengths beyond 1300-nm have demonstrated that stains are not visible and demineralization on the occlusal surfaces can be viewed without interference from stains. New extended range InGaAs near- IR cameras allow access to wavelengths beyond 1700-nm. The objective of this study was to determine how the contrast of occlusal lesions varies with wavelength from the visible to 2350-nm. The lesion contrast was measured in 55 extracted teeth with suspected occlusal lesions using reflectance measurements from 400- 2350-nm using Si and InGaAs imaging arrays. The highest lesion contrast in reflectance was measured at wavelengths greater than 1700-nm. Stains interfered significantly at wavelengths shorter than 1150-nm. This study indicates that the optimum wavelengths for reflectance imaging decay in the occlusal surfaces are greater than 1700-nm.

  8. Prospective randomized evaluation of the watchman left atrial appendage closure device in patients with atrial fibrillation versus long-term warfarin therapy: The PREVAIL trial.

    PubMed

    Belgaid, Djouhar Roufeida; Khan, Zara; Zaidi, Mariam; Hobbs, Adrian

    2016-09-15

    Assessing the safety and effectiveness of left atrial appendage (LAA) (pouch found in the upper chambers of the heart) occlusion, using the Watchman device compared to long term warfarin therapy (drug that reduces clot formation), in preventing the risk of stroke in patients with atrial fibrillation (most common type of irregular heart beat). 90% of strokes in atrial fibrillation arise from clots forming in this pouch. By mechanically blocking it using the device less clots are suggested to be formed. This is an alternative to taking warfarin especially in patients who cannot take it. 50 sites in the United States enrolled 407 participants. After being randomly allocated, the device group had 269 participants and warfarin group (comparator)had 138 participants. Patients with atrial fibrillation and at high risk of stroke were randomly allocated a group after they were deemed eligible. Patients in the device group had to take warfarin and aspirin for 45days till the complete closure of the LAA. The oral anticoagulant was followed by dual antiplatelet therapy until 6months and then ASA. Patients in the warfarin group have to take it for life and were continually monitored. The study ran for 26months. The trial assessed the rate of adverse events using three endpoints: The PREVAIL trial was not designed to show superiority, but non-inferiority. It met the safety endpoint and one efficacy endpoint for the watchman device compared to long term warfarin for overall efficacy of the device. The results established that LAA occlusion is not worse than warfarin intake for the prevention of stroke more than 1week after randomization. Compared to previous trials, the safety of the device has also improved. LAA occlusion is a reasonable alternative to chronic warfarin therapy in stroke prevention for patients with atrial fibrillation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. A preliminary study to find a possible association between occlusal wear and maximum bite force in humans.

    PubMed

    Jain, Veena; Mathur, Vijay Prakash; Kumar, Abhishek

    2013-01-01

    The objective of the study was to investigate whether moderate-to-severe attrition is associated with maximum bite force in the first molar region. Maximum bite force in the first molar region was measured for a total of 60 subjects having moderate-to-severe attrition of occlusal surface (experimental group) using a specially-designed piezoelectric sensor based bite force measuring device. An equal number of age, gender, height and weight matched controls (control group) were also subjected to bite force measurement for comparison. The maximum bite force was found to be significantly lower (p < 0.05) in the experimental group [480.32 (153.40)] as compared to the controls [640.63 (148.90)]. While analyzing the possible etiology for occlusal wear mainly two reasons were elicited, i.e. history of parafunctional habits like use of known abrasive tooth powder (sub-group A) and Bruxism (sub-group B). However, there were many subjects in which no known definite etiological factors be attributed to occlusal wear (sub-group C). On analysing further with respect to the possibly correlated etiological factors with maximum bite force, no significant difference was found within the experimental sub-group. However, all three experimental sub-groups had significantly lower maximum bite force as compared to age, gender and BMI matched controls. A significantly lower maximum bite force was found to be associated with moderate-to-severe attrition as compared to subjects without attrition. However, no specific relation could be found between bite force and possible etiological factors like history of parafunctional habits, history of use of known abrasive tooth powder, etc.

  10. Changing strategies of the retrograde approach for chronic total occlusion during the past 7 years.

    PubMed

    Muramatsu, Toshiya; Tsukahara, Reiko; Ito, Yoshiaki; Ishimori, Hiroshi; Park, Seung-Jung; de Winter, Robert; Shokry, Khaled; Wang, Lefeng; Chen, Jiyan; Wang, Haichang

    2013-03-01

    We reviewed the technical changes and results achieved with the retrograde approach since we introduced it 7 years ago. The subjects were 1,268 patients who were treated for CTO between January 2004 and December 2010. They were investigated with respect to the success rate, the frequency of employing the retrograde approach and its outcome, and other factors. The retrograde approach was employed in ∼30% of chronic total occlusion (CTO) patients (n = 281) and the retrograde guidewire success rate was 81.1%. The kissing wire technique was substituted for the retrograde approach in 126 of the 281 patients, with antegrade crossing of a guidewire being successful in 88 of them (70%). The retrograde approach was combined with the CART and reverse controlled antegrade retrograde tracking (CART) techniques in 22 and 21 patients, respectively. Among 83 patients treated with Corsair catheters, crossing of the CTO was achieved in 63. The overall procedural success rate was 79.7% (224 patients). Complications of the retrograde approach included collateral channel dissection (2.1%), channel perforation (1.7%), CTO perforation (1.7%), and donor artery occlusion (1.1%). The success rate and safety of the retrograde approach are both satisfactory if the appropriate devices and techniques are selected. Copyright © 2012 Wiley Periodicals, Inc.

  11. Influence of occlusal plane inclination and mandibular deviation on esthetics

    PubMed Central

    Corte, Cristiane Cherobini Dalla; da Silveira, Bruno Lopes; Marquezan, Mariana

    2015-01-01

    Objective: The aim of this study was to assess the degree of perception of occlusal plane inclination and mandibular deviation in facial esthetics, assessed by laypeople, dentists and orthodontists. Methods: A woman with 5.88° of inclination and 5.54 mm of mandibular deviation was selected and, based on her original photograph, four new images were created correcting the deviations and creating more symmetric faces and smiles. Examiners assessed the images by means of a questionnaire. Their opinions were compared by qualitative and quantitative analyses. Results: A total of 45 laypeople, 27 dentists and 31 orthodontists filled out the questionnaires. All groups were able to perceive the asymmetry; however, orthodontists were more sensitive, identifying asymmetries as from 4.32° of occlusal plane inclination and 4.155 mm of mandibular deviation (p< 0.05). The other categories of evaluators identified asymmetries and assigned significantly lower grades, starting from 5.88° of occlusal plane inclination and 5.54 mm of mandibular deviation (p< 0.05). Conclusion: Occlusal plane inclination and mandibular deviation were perceived by all groups, but orthodontists presented higher perception of deviations. PMID:26560821

  12. Self-expanding nanoplatinum-coated nitinol devices for atrial septal defect and patent ductus arteriosus closure: a swine model.

    PubMed

    Lertsapcharoen, Pornthep; Khongphatthanayothin, Apichai; La-orkhun, Vidhavas; Supachokchaiwattana, Pentip; Charoonrut, Phingphol

    2006-01-01

    Our purpose was to evaluate self-expanding nanoplatinum-coated nitinol devices for transcatheter closure of atrial septal defects and patent ductus arteriosus in a swine model. The devices were braided from platinum-activated nitinol wires and filled with polyester to enhance thrombogenicity. The platinum activation of the nitinol wires was carried out with the help of Nanofusion technology. The coating of platinum covers the exposed surface of the nitinol wires and prevents the release of nickel into the blood stream after the implantation of the device but does not affect its shape memory, which makes the device self-expanding after it is loaded from the catheter. Atrial septal defects were created in 12 piglets by balloon dilation of the patent foramen ovale. The size of the device was selected on the basis of the diameter of the balloon and the size of the defect, measured by transthoracic echocardiography. The devices were successfully deployed in all 12 piglets under fluoroscopic study. Transthoracic color Doppler echocardiograms showed complete closure of the atrial septal defect within 15 minutes of device implantation. Twelve patent ductus arteriosus closure devices were deployed in the right or left subclavian arteries in 10 piglets. Angiograms showed complete occlusion of the subclavian arteries within a few minutes of device deployment. In the atrial septal defect cases, the autopsy findings showed complete organizing fibrin thrombus formation and complete neo-endothelialization on the outer surface of the devices within one week and six weeks of implantation, respectively. The use of self-expanding nanoplatinum-coated nitinol devices for the transcatheter closure of atrial septal defects and patent ductus arteriosus is feasible. The excellent occlusion result and complete neo-endothelialization of the devices in the swine model is an indication of the potential of these devices in human application.

  13. Branch retinal arterial occlusion.

    PubMed

    Subedi, S; Shrestha, C

    2010-01-01

    Retinal arterial occlusion is an ocular emergency in which visual prognosis is poor mostly due to late presentation of the patient and macular involvement. The casee described, in this report is ane incidence of Branch Retinal Arterial Occlusion in a 22 year old female with grade II Mitral Regurgitation. The patiente presented witha complaint of painless, diminution of vision in the right eyn. She also presented with perception of black shadow in the superior visual fiel n of the same eye5 for five days. There was no significant systemic ord personal history. Her visual acuity at presentation was 6/60 and 6/6 in the right and left eyes,y which did not improve with glasses or pin-hole. Anterior segment including papillary reaction was normal in both eyes while Fundus examination of the right eye revealed retinal whitening inside the inferotemporal vascular arcade that was encroaching foveolar avascular zone. Visual field defect was detected at superonasally inside arhade but Fundus Fluorescence Angiography was normal. An echoycardiograph revealed grade II Mitral Regurgitation. The patient was kept on observation and after two2 days of follow-up, vision in the right eye was improved to 6/6 unaided but visual field defect was remained same.

  14. 2D model of plasma current sheath propagation in a Mather type plasma focus device

    NASA Astrophysics Data System (ADS)

    Mohamad, Saiful Najmee; Rashid, Natashah Abdul; Halim, Mohd Mahadi; Ali, Jalil

    2018-06-01

    Plasma focus device is initially developed by two known researchers back in the 1960s, Mather and Filippov. The interest on the research built due to its capability to produce high energetic neutron from a fusion reaction. The relevance of the research in Plasma Focus device remain after decade is because of its competence to produce multi radiation yield and its known physics during nanosecond of plasma compression remain open for discussed. In the recent years, the direction of the plasma research is in device optimisation, where many possible configurations have been present, discuss and highlighting its performance for differences conditions. The significant difference between the electrode configuration is the profile of the dynamics inductance. In this context, this paper comparatively discusses the 1D dynamics model of the plasma current sheath (PSC) propagation axially and radially with the 2D model. The 2D model algorithm for the PSC propagation is developed using macro (Excel) by incorporating a drag force to solve the momentum exchange of the PCS with neutral gas. The discharge current profile of both model successfully calibrated to agree with each other with 2% difference at 1.83 µs after discharge but with an expense of different assumption.

  15. [Retrospective analysis of patients with thrombocytopenia after patent ductus arteriosus interventional occlusion].

    PubMed

    Liao, Qi-wei; Zhang, Wei-hua; Guang, Xue-feng; Lu, Yi-bing

    2013-03-01

    To explore the risk factors of patent ductus arteriosus (PDA) patients with thrombocytopenia after PDA interventional occlusion. Thrombocytopenia occurred in 14 out of 350 patients underwent PDA occlusion. Age, gender, body weight, PDA size, occluder size, mean pulmonary arterial pressure, the dose of heparin, the manufacturer of occluder, residual shunt after operation were analyzed. The recovery time of different grades of thrombocytopenia was observed. Multivariate logistic regression showed that the PDA size (OR = 2.238, P < 0.05), the dose of heparin (OR = 3.247, P < 0.05), residual shunt after operation (OR = 1.912, P < 0.01) were the independent risk factors of thrombocytopenia after PDA occlusion. The recovery time of mild thrombocytopenia was (7 ± 2) days without treatment. The recovery time of moderate thrombocytopenia was (12 ± 4) days with glucocorticoids treatment. The recovery time of severe thrombocytopenia was (21 ± 7) days with platelet transfusion. The occluder size, dose of heparin, residual shunt are the independent risk factors of thrombocytopenia after PDA interventional occlusion. Recover time of thrombocytopenia after PDA interventional occlusion is closely related to the severity of thrombocytopenia.

  16. Current challenges for clinical trials of cardiovascular medical devices.

    PubMed

    Zannad, Faiez; Stough, Wendy Gattis; Piña, Ileana L; Mehran, Roxana; Abraham, William T; Anker, Stefan D; De Ferrari, Gaetano M; Farb, Andrew; Geller, Nancy L; Kieval, Robert S; Linde, Cecilia; Redberg, Rita F; Stein, Kenneth; Vincent, Alphons; Woehrle, Holger; Pocock, Stuart J

    2014-07-15

    Several features of cardiovascular devices raise considerations for clinical trial conduct. Prospective, randomized, controlled trials remain the highest quality evidence for safety and effectiveness assessments, but, for instance, blinding may be challenging. In order to avoid bias and not confound data interpretation, the use of objective endpoints and blinding patients, study staff, core labs, and clinical endpoint committees to treatment assignment are helpful approaches. Anticipation of potential bias should be considered and planned for prospectively in a cardiovascular device trial. Prospective, single-arm studies (often referred to as registry studies) can provide additional data in some cases. They are subject to selection bias even when carefully designed; thus, they are generally not acceptable as the sole basis for pre-market approval of high risk cardiovascular devices. However, they complement the evidence base and fill the gaps unanswered by randomized trials. Registry studies present device safety and effectiveness in day-to-day clinical practice settings and detect rare adverse events in the post-market period. No single research design will be appropriate for every cardiovascular device or target patient population. The type of trial, appropriate control group, and optimal length of follow-up will depend on the specific device, its potential clinical benefits, the target patient population and the existence (or lack) of effective therapies, and its anticipated risks. Continued efforts on the part of investigators, the device industry, and government regulators are needed to reach the optimal approach for evaluating the safety and performance of innovative devices for the treatment of cardiovascular disease. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    NASA Astrophysics Data System (ADS)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  18. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    PubMed

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  19. Influence of stabilization occlusal splint on craniocervical relationships. Part I: Cephalometric analysis.

    PubMed

    Moya, H; Miralles, R; Zuñiga, C; Carvajal, R; Rocabado, M; Santander, H

    1994-01-01

    This study was conducted in order to determine the effect of an occlusal splint on craniocervical relationships, in subjects with muscle spasms in the sternocleidomastoid and trapezius muscles. A full-arch maxillary stabilization occlusal splint was made for each of the 15 subjects. Two lateral craniocervical radiographs were taken for each subject, with and without an occlusal splint. Cephalometric analysis showed that the splint caused a significant extension of the head on the cervical spine. There was also a significant decrease in the cervical spine lordosis in the first, second and third cervical segment. These cervical changes could be a compensation mechanism caused by the extension of the cranium on the upper cervical spine. The change in the curvature implies that it is necessary to periodically evaluate the changes occurring in the craniocervical relationships after the occlusal splint has been inserted.

  20. Using occlusal wear information and finite element analysis to investigate stress distributions in human molars

    PubMed Central

    Benazzi, Stefano; Kullmer, Ottmar; Grosse, Ian R; Weber, Gerhard W

    2011-01-01

    Simulations based on finite element analysis (FEA) have attracted increasing interest in dentistry and dental anthropology for evaluating the stress and strain distribution in teeth under occlusal loading conditions. Nonetheless, FEA is usually applied without considering changes in contacts between antagonistic teeth during the occlusal power stroke. In this contribution we show how occlusal information can be used to investigate the stress distribution with 3D FEA in lower first molars (M1). The antagonistic crowns M1 and P2–M1 of two dried modern human skulls were scanned by μCT in maximum intercuspation (centric occlusion) contact. A virtual analysis of the occlusal power stroke between M1 and P2–M1 was carried out in the Occlusal Fingerprint Analyser (OFA) software, and the occlusal trajectory path was recorded, while contact areas per time-step were visualized and quantified. Stress distribution of the M1 in selected occlusal stages were analyzed in strand7, considering occlusal information taken from OFA results for individual loading direction and loading area. Our FEA results show that the stress pattern changes considerably during the power stroke, suggesting that wear facets have a crucial influence on the distribution of stress on the whole tooth. Grooves and fissures on the occlusal surface are seen as critical locations, as tensile stresses are concentrated at these features. Properly accounting for the power stroke kinematics of occluding teeth results in quite different results (less tensile stresses in the crown) than usual loading scenarios based on parallel forces to the long axis of the tooth. This leads to the conclusion that functional studies considering kinematics of teeth are important to understand biomechanics and interpret morphological adaptation of teeth. PMID:21615398

  1. RANKL, Osteopontin, and Osteoclast Homeostasis in a Hyper-Occlusion Mouse Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Cameron G.; Ito, Yoshihiro; Dangaria, Smit

    2010-11-15

    The biological mechanisms that maintain the position of teeth in their sockets establish a dynamic equilibrium between bone resorption and apposition. In order to reveal some of the dynamics involved in the tissue responses towards occlusal forces on periodontal ligament (PDL) and alveolar bone homeostasis, we developed the first mouse model of hyperocclusion. Swiss-Webster mice were kept in hyperocclusion for 0, 3, 6, and 9 d. Morphological and histological changes in the periodontium were assessed using micro-computed tomography (micro-CT) and ground sections with fluorescent detection of vital dye labels. Sections were stained for tartrate-resistant acid phosphatase, and the expression ofmore » receptor activator of nuclear factor-{kappa}B ligand (RANKL) and osteopontin (OPN) was analyzed by immunohistochemistry and real-time polymerase chain reaction (PCR). Traumatic occlusion resulted in enamel surface abrasion, inhibition of alveolar bone apposition, significant formation of osteoclasts at 3, 6 and 9 d, and upregulation of OPN and RANKL. Data from this study suggest that both OPN and RANKL contribute to the stimulation of bone resorption in the hyperocclusive state. In addition, we propose that the inhibition of alveolar bone apposition by occlusal forces is an important mechanism for the control of occlusal height that might work in synergy with RANKL-induced bone resorption to maintain normal occlusion.« less

  2. TREVO stent-retriever mechanical thrombectomy for acute ischemic stroke secondary to large vessel occlusion registry

    PubMed Central

    Zaidat, Osama O; Castonguay, Alicia C; Nogueira, Raul G; Haussen, Diogo C; English, Joey D; Satti, Sudhakar R; Chen, Jennifer; Farid, Hamed; Borders, Candace; Veznedaroglu, Erol; Binning, Mandy J; Puri, Ajit; Vora, Nirav A; Budzik, Ron F; Dabus, Guilherme; Linfante, Italo; Janardhan, Vallabh; Alshekhlee, Amer; Abraham, Michael G; Edgell, Randall; Taqi, Muhammad Asif; Khoury, Ramy El; Mokin, Maxim; Majjhoo, Aniel Q; Kabbani, Mouhammed R; Froehler, Michael T; Finch, Ira; Ansari, Sameer A; Novakovic, Roberta; Nguyen, Thanh N

    2018-01-01

    Background Recent randomized clinical trials (RCTs) demonstrated the efficacy of mechanical thrombectomy using stent-retrievers in patients with acute ischemic stroke (AIS) with large vessel occlusions; however, it remains unclear if these results translate to a real-world setting. The TREVO Stent-Retriever Acute Stroke (TRACK) multicenter Registry aimed to evaluate the use of the Trevo device in everyday clinical practice. Methods Twenty-three centers enrolled consecutive AIS patients treated from March 2013 through August 2015 with the Trevo device. The primary outcome was defined as achieving a Thrombolysis in Cerebral Infarction (TICI) score of ≥2b. Secondary outcomes included 90-day modified Rankin Scale (mRS), mortality, and symptomatic intracranial hemorrhage (sICH). Results A total of 634patients were included. Mean age was 66.1±14.8 years and mean baseline NIH Stroke Scale (NIHSS) score was 17.4±6.7; 86.7% had an anterior circulation occlusion. Mean time from symptom onset to puncture and time to revascularization were 363.1±264.5 min and 78.8±49.6 min, respectively. 80.3% achieved TICI ≥2b. 90-day mRS ≤2 was achieved in 47.9%, compared with 51.4% when restricting the analysis to the anterior circulation and within 6 hours (similar to recent AHA/ASA guidelines), and 54.3% for those who achieved complete revascularization. The 90-day mortality rate was 19.8%. Independent predictors of clinical outcome included age, baseline NIHSS, use of balloon guide catheter, revascularization, and sICH. Conclusion The TRACK Registry results demonstrate the generalizability of the recent thrombectomy RCTs in real-world clinical practice. No differences in clinical and angiographic outcomes were shown between patients treated within the AHA/ASA guidelines and those treated outside the recommendations. PMID:28963367

  3. Does the type and size of Amplatzer vascular plug affect the occlusion time of pulmonary arteriovenous malformations?

    PubMed Central

    Abdel-Aal, Ahmed Kamel; Massoud, Moustafa Omar; Elantably, Dina Mahmoud

    2017-01-01

    PURPOSE Occlusion time (OT) is an important factor in the treatment of pulmonary arteriovenous malformations (PAVMs) since it can lead to serious complications. The purpose of our study is to calculate the OT of Amplatzer vascular plug (AVP, St Jude Medical), and correlate it to the type of the device used (AVP or AVP 2) and the percent of device oversizing. Technical success rates and complications were also recorded. METHODS We retrospectively studied a total of 19 patients with 47 PAVMs who received percutaneous transcatheter embolization therapy using either AVP or AVP 2. We recorded the location, type, feeding artery diameter, AVP device used, and OT of each PAVM. We correlated the percent of device oversizing and the type of AVP with the OT. We also studied the rate of persistence of PAVM for both devices. RESULTS Forty-six (98%) of the PAVMs were simple. Device diameters ranged from 4.0–16.0 mm with device oversizing ranging between 14% and 120%. There was a statistically significant difference in the OT of AVP and AVP 2 (3 min 54 s vs. 5 min 30 s, P = 0.030). There was a weak positive correlation between OT and device oversizing for AVP (r=0.246, P = 0.324) and AVP 2 (r=0.261, P = 0.240). No major complications were identified. Immediate technical success rate was 100%. CONCLUSION The use of AVP 2, and increase in device oversizing were not associated with reduction in the OT of PAVMs. There was no reported difference in safety between the two devices, and no major complications were noted. PMID:27856403

  4. Innovative dressing and securement of tunneled central venous access devices in pediatrics: a pilot randomized controlled trial.

    PubMed

    Ullman, Amanda J; Kleidon, Tricia; Gibson, Victoria; McBride, Craig A; Mihala, Gabor; Cooke, Marie; Rickard, Claire M

    2017-08-30

    Central venous access device (CVAD) associated complications are a preventable source of patient harm, frequently resulting in morbidity and delays to vital treatment. Dressing and securement products are used to prevent infectious and mechanical complications, however current complication rates suggest customary practices are inadequate. The aim of this study was to evaluate the feasibility of launching a full-scale randomized controlled efficacy trial of innovative dressing and securement products for pediatric tunneled CVAD to prevent complication and failure. An external, pilot, four-group randomized controlled trial of standard care (bordered polyurethane dressing and suture), in comparison to integrated securement-dressing, suture-less securement device, and tissue adhesive was undertaken across two large, tertiary referral pediatric hospitals in Australia. Forty-eight pediatric participants with newly inserted tunneled CVADs were consecutively recruited. The primary outcome of study feasibility was established by elements of eligibility, recruitment, attrition, protocol adherence, missing data, parent and healthcare staff satisfaction and acceptability, and effect size estimates for CVAD failure (cessation of function prior to completion of treatment) and complication (associated bloodstream infection, thrombosis, breakage, dislodgement or occlusion). Dressing integrity, product costs and site complications were also examined. Protocol feasibility was established. CVAD failure was: 17% (2/12) integrated securement-dressing; 8% (1/13) suture-less securement device; 0% tissue adhesive (0/12); and, 0% standard care (0/11). CVAD complications were: 15% (2/13) suture-less securement device (CVAD associated bloodstream infection, and occlusion and partial dislodgement); 8% (1/12) integrated securement-dressing (partial dislodgement); 0% tissue adhesive (0/12); and, 0% standard care (0/11). One CVAD-associated bloodstream infection occurred, within the suture

  5. Python Scripts for Automation of Current-Voltage Testing of Semiconductor Devices (FY17)

    DTIC Science & Technology

    2017-01-01

    ARL-TR-7923 ● JAN 2017 US Army Research Laboratory Python Scripts for Automation of Current- Voltage Testing of Semiconductor...manual device-testing procedures is reduced or eliminated through automation. This technical report includes scripts written in Python , version 2.7, used ...nothing. 3.1.9 Exit Program The script exits the entire program. Line 505, sys.exit(), uses the sys package that comes with Python to exit system

  6. Genetics Home Reference: pulmonary veno-occlusive disease

    MedlinePlus

    ... G, Humbert M. Pulmonary veno-occlusive disease: clinical, functional, radiologic, and hemodynamic characteristics and outcome of 24 cases confirmed by histology. Medicine (Baltimore). 2008 Jul;87(4):220-33. doi: ...

  7. Minimally invasive per-catheter occlusion and dilation procedures for congenital cardiovascular abnormalities in dogs.

    PubMed

    Tobias, Anthony H; Stauthammer, Christopher D

    2010-07-01

    With ever-increasing sophistication of veterinary cardiology, minimally invasive per-catheter occlusion and dilation procedures for the treatment of various congenital cardiovascular abnormalities in dogs have become not only available, but mainstream. Much new information about minimally invasive per-catheter patent ductus arteriosus occlusion has been published and presented during the past few years. Consequently, patent ductus arteriosus occlusion is the primary focus of this article. Occlusion of other less common congenital cardiac defects is also briefly reviewed. Balloon dilation of pulmonic stenosis, as well as other congenital obstructive cardiovascular abnormalities is discussed in the latter part of the article.

  8. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization.

    PubMed

    Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea

    2006-08-01

    To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, p<0.0001), postdilation (63.9+/-21.0 versus 2.06+/-2.58, p<0.0001), and retrieval of the protection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.

  9. Occlusal Classification in Relation to Original Cleft Width in Patients With Unilateral Cleft Lip and Palate.

    PubMed

    Huang, Andrew H; Patel, Kamlesh B; Maschhoff, Clayton W; Huebener, Donald V; Skolnick, Gary B; Naidoo, Sybill D; Woo, Albert S

    2015-09-01

    To determine a correlation between the width of the cleft palate measured at the time of lip adhesion, definitive lip repair, and palatoplasty and the subsequent occlusal classification of patients born with unilateral cleft lip and palate. Retrospective, observational study. Referral, urban, children's hospital Participants : Dental models and records of 270 patients were analyzed. None. Angle occlusion classification. The mean age at which occlusal classification was determined was 11 ± 0.3 years. Of the children studies, 84 were diagnosed with Class I or II occlusion, 67 were diagnosed with Class III occlusion, and 119 were lost to follow up or transferred care. Mean cleft widths were significantly larger in subjects with Class III occlusion for all measures at time of lip adhesion and definitive lip repair (P < .02). At time of palatoplasty, cleft widths were significantly greater at the alveolus (P = .025) but not at the midportion of the hard palate (P = .35) or posterior hard palate (P = .10). Cleft widths from the lip through to the posterior hard palate are generally greater in children who are diagnosed with Class III occlusion later in life. Notably, the alveolar cleft width is significantly greater at each time point for patients who went on to develop Class III occlusion. There were no significant differences in cleft widths between patients diagnosed later with Class I and Class II occlusions.

  10. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

    PubMed

    Abay, T Y; Kyriacou, P A

    2016-04-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.

  11. Central Venous Occlusion in the Hemodialysis Patient.

    PubMed

    Krishna, Vinay Narasimha; Eason, Joseph B; Allon, Michael

    2016-11-01

    Central venous stenosis (CVS) is encountered frequently among hemodialysis patients. Prior ipsilateral central venous catheterization and cardiac rhythm device insertions are common risk factors, but CVS can also occur in the absence of this history. Chronic CVS can cause thrombosis with partial or complete occlusion of the central vein at the site of stenosis. CVS is frequently asymptomatic and identified as an incidental finding during imaging studies. Symptomatic CVS presents most commonly as an upper- or lower-extremity edema ipsilateral to the CVS. Previously unsuspected CVS may become symptomatic after placement of an ipsilateral vascular access. The likelihood of symptomatic CVS may be affected by the central venous catheter (CVC) location; CVC side; duration of CVC dependence; type, location, and blood flow of the ipsilateral access; and extent of collateral veins. Venous angiography is the gold standard for diagnosis. Percutaneous transluminal angioplasty and stent placement can improve the stenosis and alleviate symptoms, but CVS typically recurs frequently, requiring repeated interventions. Refractory symptomatic CVS may require ligation of the ipsilateral vascular access. Because no available treatment option is curative, the goal should be to prevent CVS by minimizing catheters and central vein instrumentation in patients with chronic kidney disease and dialysis patients. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  12. Near-IR and CP-OCT Imaging of Suspected Occlusal Caries Lesions

    PubMed Central

    Simon, Jacob C.; Kang, Hobin; Staninec, Michal; Jang, Andrew T.; Chan, Kenneth H.; Darling, Cynthia L.; Lee, Robert C.; Fried, Daniel

    2017-01-01

    Introduction Radiographic methods have poor sensitivity for occlusal lesions and by the time the lesions are radiolucent they have typically progressed deep into the dentin. New more sensitive imaging methods are needed to detect occlusal lesions. In this study, cross-polarization optical coherence tomography (CP-OCT) and near-IR imaging were used to image questionable occlusal lesions (QOC's) that were not visible on radiographs but had been scheduled for restoration on 30 test subjects. Methods Near-IR reflectance and transillumination probes incorporating a high definition InGaAs camera and near-IR broadband light sources were used to acquire images of the lesions before restoration. The reflectance probe utilized cross-polarization and operated at wavelengths from 1500–1700-nm where there is an increase in water absorption for higher contrast. The transillumination probe was operated at 1300-nm where the transparency of enamel is highest. Tomographic images (6×6×7 mm3) of the lesions were acquired using a high-speed swept-source CP-OCT system operating at 1300-nm before and after removal of the suspected lesion. Results Near-IR reflectance imaging at 1500–1700-nm yielded significantly higher contrast (p<0.05) of the demineralization in the occlusal grooves compared with visible reflectance imaging. Stains in the occlusal grooves greatly reduced the lesion contrast in the visible range yielding negative values. Only half of the 26 lesions analyzed showed the characteristic surface demineralization and increased reflectivity below the dentinal-enamel junction (DEJ) in 3D OCT images indicative of penetration of the lesion into the dentin. Conclusion This study demonstrates that near-IR imaging methods have great potential for improving the early diagnosis of occlusal lesions. PMID:28339115

  13. Transcutaneous closure of chronic broncho-pleuro-cutaneous fistula by duct occluder device

    PubMed Central

    Marwah, Vikas; Ravikumar, R; Rajput, Ashok Kumar; Singh, Amandeep

    2016-01-01

    Bronchopleural fistula (BPF) is a well known complication of several pulmonary conditions posing challenging management problem and is often associated with high morbidity and mortality. Though no consensus exists on a definite closure management algorithm, strategies for closure widely include various methods like tube thoracostomy with suction, open surgical closure, bronchoscopy directed glue, coiling and sealants which now also includes use of occlusion devices. We report a case in which a novel method of delivery and closure of recurrent post-operative broncho-pleuro-cutaneous fistula by a duct occluder device was done transcutaneously which has not been previously described in literature. PMID:27051115

  14. Repeated arterial occlusion, delta-opioid receptor (DOR) plasticity and vagal transmission within the sinoatrial node of the anesthetized dog.

    PubMed

    Deo, Shekhar H; Barlow, Matthew A; Gonzalez, Leticia; Yoshishige, Darice; Caffrey, James L

    2009-01-01

    Brief interruptions in coronary blood flow precondition the heart, engage delta-opioid receptor (DOR) mechanisms and reduce the damage that typically accompanies subsequent longer coronary occlusions. Repeated short occlusions of the sinoatrial (SA) node artery progressively raised nodal methionine-enkephalin-arginine-phenylalanine (MEAP) and improved vagal transmission during subsequent long occlusions in anesthetized dogs. The DOR type-1 (DOR-1) antagonist, BNTX reversed the vagotonic effect. Higher doses of enkephalin interrupted vagal transmission through a DOR-2 mechanism. The current study tested whether the preconditioning (PC) protocol, the later occlusion or a combination of both was required for the vagotonic effect. The study also tested whether evolving vagotonic effects included withdrawal of competing DOR-2 vagolytic influences. Vagal transmission progressively improved during successive SA nodal artery occlusions. The vagotonic effect was absent in sham animals and after DOR-1 blockade. After completing the PC protocol, exogenously applied vagolytic doses of MEAP reduced vagal transmission under both normal and occluded conditions. The magnitude of these DOR-2 vagolytic effects was small compared to controls and repeated MEAP challenges rapidly eroded vagolytic responses further. Prior DOR-1 blockade did not alter the PC mediated, progressive loss of DOR-2 vagolytic responses. In conclusion, DOR-1 vagotonic responses evolved from signals earlier in the PC protocol and erosion of competing DOR-2 vagolytic responses may have contributed to an unmasking of vagotonic responses. The data support the hypothesis that PC and DOR-2 stimulation promote DOR trafficking, and down regulation of the vagolytic DOR-2 phenotype in favor of the vagotonic DOR-1 phenotype. DOR-1 blockade may accelerate the process by sequestering newly emerging receptors.

  15. Caries detection: current status and future prospects using lasers

    NASA Astrophysics Data System (ADS)

    Longbottom, Christopher

    2000-03-01

    Caries detection currently occupies a good deal of attention in the arena of dental research for a number of reasons. In searching for caries detection methods with greater accuracy than conventional technique researchers have used a variety of optical methods and have increasingly turned to the use of lasers. Several laser-based methods have been and are being assessed for both imaging and disease quantification techniques. The phenomenon of fluorescence of teeth and caries in laser light and the different effects produced by different wavelengths has been investigated by a number of workers in Europe. With an argon ion laser excitation, QLF (Quantified Laser Fluorescence) demonstrated a high correlation between loss of fluorescence intensity and enamel mineral loss in white spot lesions in free smooth surface lesions, both in vitro and in vivo. Recent work with a red laser diode source (655 nm), which appears to stimulate bacterial porphyrins to fluoresce, has demonstrated that a relatively simple device based on this phenomenon can provide sensitivity and specificity values of the order of 80% in vitro and in vivo for primary caries at occlusal sites. In vitro studies using a simulated in vivo methodology indicate that the device can produce sensitivity values of the order of 90% for primary caries at approximal sites.

  16. Numerical Simulation of Thrombotic Occlusion in Tortuous Arterioles

    PubMed Central

    Feng, Zhi-Gang; Cortina, Miguel; Chesnutt, Jennifer KW; Han, Hai-Chao

    2017-01-01

    Tortuous microvessels alter blood flow and stimulate thrombosis but the physical mechanisms are poorly understood. Both tortuous microvessels and abnormally large platelets are seen in diabetic patients. Thus, the objective of this study was to determine the physical effects of arteriole tortuosity and platelet size on the microscale processes of thrombotic occlusion in microvessels. A new lattice-Boltzmann method-based discrete element model was developed to simulate the fluid flow field with fluid-platelet coupling, platelet interactions, thrombus formation, and thrombotic occlusion in tortuous arterioles. Our results show that vessel tortuosity creates high shear stress zones that activate platelets and stimulate thrombus formation. The growth rate depends on the level of tortuosity and the pressure and flow boundary conditions. Once thrombi began to form, platelet collisions with thrombi and subsequent activations were more important than tortuosity level. Thrombus growth narrowed the channel and reduced the flow rate. Larger platelet size leads to quicker decrease of flow rate due to larger thrombi that occluded the arteriole. This study elucidated the important roles that tortuosity and platelet size play in thrombus formation and occlusion in arterioles. PMID:29327739

  17. Measurement of periapical pressure created by occlusal loading.

    PubMed

    Dobó-Nagy, C; Fejérdy, P; Angyal, J; Harasztosi, L; Daróczi, L; Beke, D; Wesselink, P R

    2003-10-01

    To develop an in vitro model in which the pressure in the periapical tissues can be measured during loading. Extracted human maxillary central incisors were embedded in resin blocks that had physical characteristics similar to those of bone and periodontal ligament. Each tooth was loaded with 20, 40, 50, 60, 75, 85, 100, 200, 300 and 450 N vertical forces from the incisal edge of the crown on three consecutive occasions. A minute resistor embedded in the periapical space was used to detect apical pressure changes during occlusal loading. The ratio of apical pressure changes (DeltaP) to the loading force changes (DeltaF) was calculated. The periapical pressure detected was in direct proportion to the loading force. The mean value of DeltaP/DeltaF was 5.994 kPa N-1 (SD = 2.04). Direct proportionality was found between the coronal loading and the apical hydrostatic pressure. The DeltaP/DeltaF ratio determined in this study makes it easier to estimate the apical hydrostatic pressure values during occlusal loading of single-rooted teeth. In this study, the apical pressure generated under occlusal loading was the same magnitude as that estimated with the finite element method.

  18. A Novel Carotid Device for Embolic Diversion: Lessons Learned from a 'First in Man' Trial in Patients with Atrial Fibrillation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sievert, Horst, E-mail: info@cvcfrankfurt.de; Franke, Jennifer; Grad, Ygael

    Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotidmore » duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.« less

  19. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    PubMed

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  20. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... CITIZENS BAND BASE STATION ANTENNAS Pt. 1204, Figs. 1, 2 Figures 1 and 2 to Part 1204—Suggested Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  1. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... CITIZENS BAND BASE STATION ANTENNAS Pt. 1204, Figs. 1, 2 Figures 1 and 2 to Part 1204—Suggested Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  2. Binocular versus standard occlusion or blurring treatment for unilateral amblyopia in children aged three to eight years.

    PubMed

    Tailor, Vijay; Bossi, Manuela; Bunce, Catey; Greenwood, John A; Dahlmann-Noor, Annegret

    2015-08-11

    to enrolment, participants were to have undergone a cycloplegic refraction and comprehensive ophthalmic examination including fundal examination. In addition, participants had to have completed a period of optical treatment, if indicated, and BCVA in the amblyopic eye had to remain unchanged on two consecutive assessments despite reportedly good compliance with glasses wearing. Participants were not to have received any treatment other than optical treatment prior to enrolment. We planned to include any type of binocular viewing intervention; these could be delivered on different devices including computer monitors viewed with LCD shutter glasses or hand-held screens including mobile phone screens with lenticular prism overlay. Control groups were to have received standard amblyopia treatment; this could include occlusion or pharmacological blurring of the better-seeing eye. We planned to include full-time (all waking hours) and part-time (between 1 and 12 hours a day) occlusion regimens. We planned to use standard methodological procedures expected by The Cochrane Collaboration. We had planned to meta-analyse the primary outcome, that is mean distance BCVA in the amblyopic eye at 12 months after the cessation of treatment. We could identify no RCTs in this subject area. Further research is required to allow decisions about implementation of binocular treatments for amblyopia in clinical practice. Currently there are no clinical trials offering standardised evidence of the safety and effectiveness of binocular treatments, but results from non-controlled cohort studies are encouraging. Future research should be conducted in the form of RCTs, using acknowledged methods of visual acuity and stereoacuity assessment with known reproducibility. Other important outcome measures include outcomes reported by users, compliance with treatment, and recurrence of amblyopia after cessation of treatment.

  3. Effects of retraction force and anchorage reinforcement on occlusal force: a model study.

    PubMed

    Kim, MoonHee; Seol, Kyung-sim; Lee, Yoonjung; Park, Jiman; Kim, Minji; Chun, Youn-Sic

    2014-10-01

    The aim of this study was to investigate the effects of retraction force and anchorage reinforcement with orthodontic mini implants on occlusal force. A strain gauge was attached to the palatal surface of the maxillary right first molar on an en masse retraction model. Occlusal forces were measured from this model, according to different retraction forces that were generated by elastic chain, under varied compressive forces (simulating masticatory forces). This retraction experiment was then performed again, after using anchorage reinforcement with an orthodontic mini implant. Occlusal force decreased as retraction force increased. The decrease showed a significant difference above 150g of retraction force (P < 0.05) and was more definite under compressive force higher than 150 N (P < 0.001). After anchorage reinforcement with the orthodontic mini implant, however, occlusal force did not significantly decrease with increasing retraction force. Significant differences in occlusal force were noted between the conditions with and without anchorage reinforcement when the applied retraction force was greater than 200g. Occlusal force tends to decrease during retraction, and this decrease can be prevented by anchorage reinforcement with orthodontic mini implants. Further investigation on the actual masticatory process in humans is required for more clear clinical implication. © The Author 2013. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. [Clinical evaluation of preadjusted appliance based on Chinese normal occlusion].

    PubMed

    Chen, Lin; Gao, Xue-Mei; Zeng, Xiang-Long

    2008-02-01

    To evaluate the effect of the preadjusted appliance (Z1 appliance) based on Chinese normal occlusion. Thirty non-extraction patients were treated with Z1 appliance. No wire bending was made during treatment. The results of these 30 cases had been evaluated by five senior orthodontists. Models were analysed quantitatively to testify and evaluate the efficiency of the appliance. The average score for post-treatment models was 91.2 (total score was 100). The model measurements indicated that average projective distance on occlusal plane between proximal contact points of adjacent teeth was less than 0.3 mm, which demonstrated good alignment. The prominence of crowns was almost coincident with the data of Chinese normal occlusion. For the average tip of most teeth, there was no statistical difference between the study group and the normal control group. The crown torque variation tendency from anterior to posterior was similar to that in the subjects with normal occlusion. However, the cases treated with Z1 appliance achieved more negative torque in the lower posterior segment. The result of the non-extraction patients treated with Z1 appliance was quite satisfied. Wire bending could be reduced during treatment. It was necessary to adjust the crown torque values for lower posterior teeth.

  5. Intracardiac versus transesophageal echocardiography for left atrial appendage occlusion with watchman.

    PubMed

    Frangieh, Antonio H; Alibegovic, Jasmina; Templin, Christian; Gaemperli, Oliver; Obeid, Slayman; Manka, Robert; Holy, Erik W; Maier, Willibald; Lüscher, Thomas F; Binder, Ronald K

    2017-08-01

    Left atrial appendage occlusion (LAAO) is mostly performed by transesophageal echocardiography (TEE) guidance. Intracardiac echocardiography (ICE) may be an alternative imaging modality for LAAO that precludes the need for general anesthesia or sedation. All consecutive single center, single operator LAAO candidates were analyzed. Baseline clinical and procedural characteristics and in-hospital outcomes were compared between patients in whom a Watchman was implanted with ICE vs. TEE guidance. In 76 consecutive patients the Watchman device was deployed under ICE in 32 patients (42%) and under TEE guidance in 44 patients (58%). Baseline characteristics were comparable between groups, except that patients in the TEE group were older (81 [75-85] years vs. 75 [68-80] years, P = 0.007). Total injected contrast media as well as fluoroscopy time were comparable between groups (90 ml [54-140] vs. 85 ml [80-110], P = 0.86 and 7.9 min [6.4-15.5] vs. 9.8 min [7.0-13.2], P = 0.51, for TEE vs. ICE, respectively). However, time from femoral venous puncture to transseptal puncture and to closure was longer in the ICE group (14 min [7.3-20] vs. 6 min [3.3-11], P = 0.007 and 48 min [40-60] vs. 34.5 min [27-44], P = 0.003, respectively). In the TEE group one patient suffered esophageal erosion with bleeding, which was managed conservatively and one non-LAAO related in-hospital mortality occurred in an 88-year-old patient. Device implantation success rate was 100% in both groups. No device embolization, no significant peri-device leak, no tamponade, no stroke, and no access site bleeding occurred in any patient. Total hospital stay for stand-alone LAAO was comparable between groups (2 days [2-2] vs. 2 days [2-3.3], P = 0.17, in ICE vs. TEE, respectively). ICE guidance for LAAO with the Watchman device is feasible and comparable to TEE and may become the preferred imaging modality for LAAO. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Central retinal artery occlusion in an ANCA negative Churg-Strauss syndrome patient.

    PubMed

    Türkçüoğlu, Peykan; Isik, Ahmet; Deniz, Nurettin; Turgut, Burak; Kan, Elif Kiliç

    2007-12-01

    To describe a central retinal artery occlusion in a patient with antineutrophil cytoplasmic antibody (ANCA) negative Churg-Strauss syndrome. Review of clinical and laboratory findings of a 44-year-old woman with ANCA negative Churg-Strauss syndrome that developed sudden vision loss in left eye. Left central retinal artery occlusion was diagnosed by retinal whitening, a cherry-red spot, and delayed arterial filling on fluorescein angiography. Perinuclear ANCA and cytoplasmic ANCA were negative. Central retinal artery occlusion can occur in ANCA negative Churg-Strauss syndrome. Patients with this diagnosis should be considered for prophylactic high dose corticosteroid, regardless of their ANCA status.

  7. OCT aspects of dental hard tissue changes induced by excessive occlusal forces

    NASA Astrophysics Data System (ADS)

    Scrieciu, Monica; Mercuţ, Veronica; Popescu, Sanda Mihaela; Tǎrâţǎ, Daniela; Osiac, Eugen

    2018-03-01

    The study purpose is to highlight dental hard tissues changes of a tooth with dental wear as a consequence of excessive occlusal forces, using OCT. Methods: a central incisor extracted for periodontal reason was cleaned and it was embedded in a black acrylic resin block. The block was sectioned along the longitudinal axis of the tooth and prepared for OCT analysis. Results: The OCT signal showed differences between the labial and palatal dental hard tissue structures, even in areas without excessive occlusal solicitations. Conclusion: The OCT signal highlights changes of dental hard tissues structures according to excessive occlusal solicitations areas.

  8. Recognition and Matching of Clustered Mature Litchi Fruits Using Binocular Charge-Coupled Device (CCD) Color Cameras

    PubMed Central

    Wang, Chenglin; Tang, Yunchao; Zou, Xiangjun; Luo, Lufeng; Chen, Xiong

    2017-01-01

    Recognition and matching of litchi fruits are critical steps for litchi harvesting robots to successfully grasp litchi. However, due to the randomness of litchi growth, such as clustered growth with uncertain number of fruits and random occlusion by leaves, branches and other fruits, the recognition and matching of the fruit become a challenge. Therefore, this study firstly defined mature litchi fruit as three clustered categories. Then an approach for recognition and matching of clustered mature litchi fruit was developed based on litchi color images acquired by binocular charge-coupled device (CCD) color cameras. The approach mainly included three steps: (1) calibration of binocular color cameras and litchi image acquisition; (2) segmentation of litchi fruits using four kinds of supervised classifiers, and recognition of the pre-defined categories of clustered litchi fruit using a pixel threshold method; and (3) matching the recognized clustered fruit using a geometric center-based matching method. The experimental results showed that the proposed recognition method could be robust against the influences of varying illumination and occlusion conditions, and precisely recognize clustered litchi fruit. In the tested 432 clustered litchi fruits, the highest and lowest average recognition rates were 94.17% and 92.00% under sunny back-lighting and partial occlusion, and sunny front-lighting and non-occlusion conditions, respectively. From 50 pairs of tested images, the highest and lowest matching success rates were 97.37% and 91.96% under sunny back-lighting and non-occlusion, and sunny front-lighting and partial occlusion conditions, respectively. PMID:29112177

  9. Occlusion therapy of unilateral amblyopia with botulinum toxin induced ptosis.

    PubMed

    Halkiadakis, Ioannis; Iliaki, Olga; Kalyvianaki, Maria I; Tsilimbaris, Miltiadis K

    2007-01-01

    In order to evaluate the role of botulinum toxin induced ptosis as an occlusion method to treat unilateral deep strabismic amblyopia in two uncooperative children, we injected 0.2 ml of diluted botulinum toxin in the levator palpaebrae; low sedation was necessary in one of the two children. In both cases a marked ptosis was achieved, which lasted about four weeks and then gradually resolved completely. The visual acuity of the ablyopic eye increased in both children, making patching easy thereafter. One child developed amblyopia in the injected eye, which was handled successfully using part-time occlusion. No other side effects were noted. Whether this new method could be a simple, safe and effective alternative method of occlusion for the treatment of deep amblyopia in uncooperative children needs to be proven with a larger series of children.

  10. Recent advances in plasma devices based on plasma lens configuration for manipulating high-current heavy ion beams.

    PubMed

    Dobrovolskiy, A; Dunets, S; Evsyukov, A; Goncharov, A; Gushenets, V; Litovko, I; Oks, E

    2010-02-01

    We describe new results of development of novel generation cylindrical plasma devices based on the electrostatic plasma lens configuration and concept of electrons magnetic insulation. The crossed electric and magnetic fields plasma lens configuration provides us with the attractive and suitable method for establishing a stable plasma discharge at low pressure. Using plasma lens configuration in this way some cost-effective plasma devices were developed for ion treatment and deposition of exotic coatings and the effective lens was first proposed for manipulating high-current beams of negatively charged particles. Here we describe operation and features of these plasma devices, and results of theoretical consideration of mechanisms determining their optimal operation conditions.

  11. Optimal occlusion uniformly partitions red blood cells fluxes within a microvascular network

    PubMed Central

    Tu, Shenyinying; Liu, Yu-Hsiu; Savage, Van M.; Hsiai, Tzung K.; Roper, Marcus

    2017-01-01

    In animals, gas exchange between blood and tissues occurs in narrow vessels, whose diameter is comparable to that of a red blood cell. Red blood cells must deform to squeeze through these narrow vessels, transiently blocking or occluding the vessels they pass through. Although the dynamics of vessel occlusion have been studied extensively, it remains an open question why microvessels need to be so narrow. We study occlusive dynamics within a model microvascular network: the embryonic zebrafish trunk. We show that pressure feedbacks created when red blood cells enter the finest vessels of the trunk act together to uniformly partition red blood cells through the microvasculature. Using mathematical models as well as direct observation, we show that these occlusive feedbacks are tuned throughout the trunk network to prevent the vessels closest to the heart from short-circuiting the network. Thus occlusion is linked with another open question of microvascular function: how are red blood cells delivered at the same rate to each micro-vessel? Our analysis shows that tuning of occlusive feedbacks increase the total dissipation within the network by a factor of 11, showing that uniformity of flows rather than minimization of transport costs may be prioritized by the microvascular network. PMID:29244812

  12. Occlusal stabilization splint therapy in orofacial pain and tension-type headache.

    PubMed

    Kostrzewa-Janicka, J; Mierzwinska-Nastalska, E; Rolski, D; Szczyrek, P

    2013-01-01

    Studies suggest an association between orofacial pain, accompanying temporomandibular disorders of myogenous origin, and headache, especially its tension-type. The occlusal appliance therapy is one of the options for the treatment of orofacial pain due to masticatory muscles tenderness. The aim of the present study was to assess the effectiveness of occlusal stabilization splint therapy in myofascial pain and tension-type headache in patients with sleep-disordered breathing. Forty three such patients were enrolled into the study group. The patients were treated with stabilization occlusal splint of vertical thickness at vertical jaw separation, established individually for each patient using a cephalometric analysis. The intensity of orofacial pain (numeric rating scale) and headache (analog rating scale), frequency of headache (%), and jaw qualitative function were assessed at baseline and after 2 and 6 months. Medians of headache and orofacial pain intensity were reduced after 6 months of treatment compared with baseline: 6.0 vs. 2.0 (p < 0.0001) and 6.0 vs. 1.0 (p < 0.0001), respectively. Pain decreased below 3 score points in 61.8 % of the patients with headache (p = 0.23) and in 85.3 % of patients with orofacial pain (p < 0.0001). Overall, the improvement in both signs and symptoms of orofacial pain was observed 81.4 % of patients after using occlusal stabilization splint for 6 months. We conclude that occlusal stabilization splint was effective in reducing painful symptoms of temporomandibular disorders of myogenous origin, a frequent feature of sleep disordered breathing.

  13. Large arterial occlusive strokes as a medical emergency: need to accurately predict clot location.

    PubMed

    Vanacker, Peter; Faouzi, Mohamed; Eskandari, Ashraf; Maeder, Philippe; Meuli, Reto; Michel, Patrik

    2017-10-01

    Endovascular treatment for acute ischemic stroke with a large intracranial occlusion was recently shown to be effective. Timely knowledge of the presence, site, and extent of arterial occlusions in the ischemic territory has the potential to influence patient selection for endovascular treatment. We aimed to find predictors of large vessel occlusive strokes, on the basis of available demographic, clinical, radiological, and laboratory data in the emergency setting. Patients enrolled in ASTRAL registry with acute ischemic stroke and computed tomography (CT)-angiography within 12 h of stroke onset were selected and categorized according to occlusion site. Easily accessible variables were used in a multivariate analysis. Of 1645 patients enrolled, a significant proportion (46.2%) had a large vessel occlusion in the ischemic territory. The main clinical predictors of any arterial occlusion were in-hospital stroke [odd ratios (OR) 2.1, 95% confidence interval 1.4-3.1], higher initial National Institute of Health Stroke Scale (OR 1.1, 1.1-1.2), presence of visual field defects (OR 1.9, 1.3-2.6), dysarthria (OR 1.4, 1.0-1.9), or hemineglect (OR 2.0, 1.4-2.8) at admission and atrial fibrillation (OR 1.7, 1.2-2.3). Further, the following radiological predictors were identified: time-to-imaging (OR 0.9, 0.9-1.0), early ischemic changes (OR 2.3, 1.7-3.2), and silent lesions on CT (OR 0.7, 0.5-1.0). The area under curve for this analysis was 0.85. Looking at different occlusion sites, National Institute of Health Stroke Scale and early ischemic changes on CT were independent predictors in all subgroups. Neurological deficits, stroke risk factors, and CT findings accurately identify acute ischemic stroke patients at risk of symptomatic vessel occlusion. Predicting the presence of these occlusions may impact emergency stroke care in regions with limited access to noninvasive vascular imaging.

  14. First Indian single center experience with pipeline embolization device for complex intracranial aneurysms.

    PubMed

    Cherian, Mathew P; Yadav, Manish Kumar; Mehta, Pankaj; Vijayan, K; Arulselvan, V; Jayabalan, Suresh

    2014-01-01

    Flow diversion is a novel method of therapy wherein an endoluminal sleeve, the flow diverter stent is placed across the neck of complex aneurysms to curatively reconstruct abnormal vasculature. We present the first Indian single center experience with the pipeline embolization device (PED) and 6 months follow-up results of 5 patients. Five complex or recurrent intracranial aneurysms in five patients were treated with PED. The patients were followed-up with magnetic resonance angiography (MRA) after 4 weeks and conventional angiography after 6 months. Feasibility, complications, clinical outcome, early 1-month MRA and 6 months conventional angiographic follow-up results were analyzed. Of the five aneurysms treated, four were in the anterior circulation and one in the posterior circulation. All five patients were treated with a single PED in each, and additionally coils were used in one patient. At 1-month MRA follow-up, complete occlusion was seen in 2 (40%) of the five cases. Post 6 months conventional angiography showed complete occlusion of the aneurysm sac in all five cases (100%). Side branch ostia were covered in three patients, all of which were patent (100%). There was no incidence of major neurological morbidity or mortality. One patient (20%) who had basilar top aneurysm experienced minor neurological disability after 5 days which partially improved. Pipeline embolization device for complex and recurrent aneurysms is technically feasible, safe, offers low complication rate, and definitive vascular reconstruction. PED can be used without fear of occlusion of covered eloquent side branches and perforators.

  15. Bilateral Medial Medullary Infarction with Nondominant Vertebral Artery Occlusion.

    PubMed

    Zhang, Lei; Zhang, Gui-lian; Du, Ju-mei; Ma, Zhu-lin

    2015-09-01

    Bilateral medial medullary infarction (MMI) is a rare stroke subtype. Here, we report a case with bilateral MMI caused by nondominant vertebral artery occlusion confirmed by brain digital subtraction angiography and magnetic resonance imaging basi-parallel-anatomical-scanning. We highlight that anterior spinal arteries could originate from a unilateral vertebral artery (VA). Radiologists and neurologists should pay attention to the nondominant VA as bilateral MMI may be induced by occlusion of nondominant VA that supplies the bilateral anteromedial territories of the medulla. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  16. [Rectal endometriosis: An exceptional etiology of acute intestinal occlusion].

    PubMed

    Doh, Kwame; Thiam, Ibou; Ka, Sidy; Dial, Cherif; Woto-Gaye, Gisèle

    2016-12-01

    The intestinal occlusion acute is an emergency and therapeutic diagnostic. A rectal tumor is rarely the cause in a young adult. We are carrying the case of a patient of 43years old, received at emergency on a board of intestinal occlusion acute due to a rectal tumor of a fortuitous discovery during the operation. The final diagnosis after a histopathologic examination was for the less unexpected. It was rectal endometriosis in its tumor-like. A complementary medical care obtains satisfactory results. Copyright © 2016. Published by Elsevier Masson SAS.

  17. A comparative study of two methods for the orientation of the occlusal plane and the determination of the vertical dimension of occlusion in edentulous patients.

    PubMed

    Koller, M M; Merlini, L; Spandre, G; Palla, S

    1992-07-01

    The aim of this study was to compare two methods used to orientate the occlusal plane (OP) and to determine the vertical dimension of occlusion (VDO). In method A the VDO was established by means of the rest position, the minimal speaking distance, and the patient's profile. Method B used a newly developed registration pin assembly. The VDO was registered using a silicone occlusion rim and the swallowing technique. The results were compared to the values of the new dentures. Three standardized lateral radiographs were taken at the VDO obtained with methods A, B, and at that of the final dentures. On each radiograph the orientation of the OP to the Camper plane and the VDO were measured by two investigators independently. The results indicated no statistically significant differences between the mean VDO with method A and B compared with the new dentures (P greater than 0.05). With both methods it was not possible to orientate the OP parallel to the Camper plane. None of the occlusal planes of the new dentures were parallel either. Their OP diverged on average by 7 degrees dorso-caudally. The time spent with method B to orient the OP and to determine the VDO was significantly lower than with method A (17-50 min).

  18. Comparison of occlusal discomfort in patients with temporomandibular disorders between myofascial pain and disc displacement.

    PubMed

    Shibuya, Toshihisa; Kino, Koji; Sugisaki, Masashi; Sato, Fumiaki; Haketa, Tadasu; Nishiyama, Akira; Takaoka, Michiko; Ota, Takenobu; Ishikawa, Takayuki; Narita, Noriyuki

    2009-12-01

    We compared occlusal discomfort in patients with temporomandibular disorders (TMD) between myofascial pain (MFP) and disc displacement (DD) using a database created from Sep, 2003 to Aug, 2005. We selected 71 patients with MFP and 170 patients with DD to construct a null model of structural equation modeling (SEM) in which anxiety influenced depressive mood, depressive mood aggravated occlusal discomfort and sleep complaints, and sleep complaints or an onset event caused by another person aggravated occlusal discomfort. We performed a simultaneous analysis of patients with MFP and DD. The estimated parameter of the path from depressive mood to occlusal discomfort was significant for patients with MFP, but not for patients with DD. The path from an onset event caused by another person, such as dental treatment to occlusal discomfort was significant in patients with MFP and those with DD. The Goodness of Fit Index (=0.909), The Adjusted Goodness of Fit Index (=0.867), and The Root Mean Square Error of Approximation (=0.039) indicated good acceptability. These results suggested that an increase in depressive mood may aggravate occlusal discomfort in patients with MFP, and an onset event caused by another person, such as dental treatment, also may aggravate occlusal discomfort in patients with MFP and those with DD.

  19. Endobronchial occlusive disease: Nd:YAG or PDT?

    NASA Astrophysics Data System (ADS)

    Regal, Anne-Marie; Takita, Hiroshi

    1991-06-01

    Patients with endobronchial occlusion commonly experience dyspnea, cough, hemoptysis, pneumonitis, and atelectasis. If luminal patency is not re-established, obstructive symptoms may progress to sepsis and death. Although the overall survival of patients with lung cancer may not be altered by relief of airway obstruction, the prognosis for this subset of patients may be improved by eliminating the septic complications of bronchial occlusion. Techniques to treat occluded bronchi include electro-fulguration, cryotherapy, brachytherapy, laser (CO2, Nd-YAG) therapy, and photodynamic therapy (PDT). These represent local forms of treatment and are intended to be palliative. Nd-YAG and PDT are the modalities more frequently utilized in this setting. Comparison of the two treatment forms may furnish insight regarding the appropriate role for each as individual therapies and as part of the armamentarium of cancer therapies.

  20. Immediate Flow Disruption as a Prognostic Factor After Flow Diverter Treatment: Long-Term Experience with the Pipeline Embolization Device.

    PubMed

    Dodier, Philippe; Frischer, Josa M; Wang, Wei-Te; Auzinger, Thomas; Mallouhi, Ammar; Serles, Wolfgang; Gruber, Andreas; Knosp, Engelbert; Bavinzski, Gerhard

    2018-05-01

    To report long-term results after Pipeline Embolization Device (PED) implantation, characterize complex and standard aneurysms comprehensively, and introduce a modified flow disruption scale. We retrospectively reviewed a consecutive series of 40 patients harboring 59 aneurysms treated with 54 PEDs. Aneurysm complexity was assessed using our proposed classification. Immediate angiographic results were analyzed using previously published grading scales and our novel flow disruption scale. According to our new definition, 46 (78%) aneurysms were classified as complex. Most PED interventions were performed in the paraophthalmic and cavernous internal carotid artery segments. Excellent neurologic outcome (modified Rankin Scale 0 and 1) was observed in 94% of patients. Our data showed low permanent procedure-related mortality (0%) and morbidity (3%) rates. Long-term angiographic follow-up showed complete occlusion in 81% and near-total obliteration in a further 14%. Complete obliteration after deployment of a single PED was achieved in all standard aneurysms with 1-year follow-up. Our new scale was an independent predictor of aneurysm occlusion in a multivariable analysis. All aneurysms with a high flow disruption grade showed complete occlusion at follow-up regardless of PED number or aneurysm complexity. Treatment with the PED should be recognized as a primary management strategy for a highly selected cohort with predominantly complex intracranial aneurysms. We further show that a priori assessment of aneurysm complexity and our new postinterventional angiographic flow disruption scale predict occlusion probability and may help to determine the adequate number of per-aneurysm devices. Copyright © 2018 Elsevier Inc. All rights reserved.