Sample records for occultation

  1. 21 CFR 864.6550 - Occult blood test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Occult blood test. 864.6550 Section 864.6550 Food... DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is...

  2. 21 CFR 864.6550 - Occult blood test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Occult blood test. 864.6550 Section 864.6550 Food... DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is...

  3. 21 CFR 864.6550 - Occult blood test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Occult blood test. 864.6550 Section 864.6550 Food... DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is...

  4. 21 CFR 864.6550 - Occult blood test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Occult blood test. 864.6550 Section 864.6550 Food... DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is...

  5. 21 CFR 864.6550 - Occult blood test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Occult blood test. 864.6550 Section 864.6550 Food... DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6550 Occult blood test. (a) Identification. An occult blood test is a device used to detect occult blood in urine or feces. (Occult blood is...

  6. [Clinical assessment of occult infections in children].

    PubMed

    Sporisević, L; Bajraktarević, A; Begić, Z

    2000-01-01

    Children's occult infections are characterised presenting pathogenic bacteries in blood of children in age 3 to 36 months, but they are good general aspect and orderly immunologic status and they don't have signs of focal infection. Manifestation of occult infections determined: age of child, increasing bodies temperature, testsphysical observance and clinical-biochemistry tests. Prevalence of manifestation occult infections is 3-8%, but they manifest ni a form occult bacteremia, occult pneumonia nad occult urinary infection. Methodic, systematic admission and adequate clinical-biochemical monitoring, we minimise sequeles of occult infections. Risk of serious sequeles at occult infections is importantly decreasing by epidemiological changes that it rises by using vaccination against Haemophilus influenzae and Streptococcus pneumoniae is leading ethiological source. Many contraversal opinions are presented in glance of therapeutic strategy at children's occult infection. Future of solutions at many hesitations ni context diagnosis and therapy of occult infections is established in using recent detectional tests /pneumococcus PCR, plasmas tumor reaction, interleukin lâ/ and preventive intervetions activities /conjugated pneumococcus vaccination/.

  7. Progress on an external occulter testbed at flight Fresnel numbers

    NASA Astrophysics Data System (ADS)

    Kim, Yunjong; Sirbu, Dan; Galvin, Michael; Kasdin, N. Jeremy; Vanderbei, Robert J.

    2016-01-01

    An external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. Laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we have designed and built a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. The occulter testbed uses 78 m optical propagation distance to realize the flight Fresnel numbers. We will use an etched silicon mask as the occulter. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. Here, we present first light result of a sample design operating at a flight Fresnel number and the mechanical design of the testbed. We compare the experimental results with simulations that predict the ultimate contrast performance.

  8. Method of Modeling and Simulation of Shaped External Occulters

    NASA Technical Reports Server (NTRS)

    Lyon, Richard G. (Inventor); Clampin, Mark (Inventor); Petrone, Peter, III (Inventor)

    2016-01-01

    The present invention relates to modeling an external occulter including: providing at least one processor executing program code to implement a simulation system, the program code including: providing an external occulter having a plurality of petals, the occulter being coupled to a telescope; and propagating light from the occulter to a telescope aperture of the telescope by scalar Fresnel propagation, by: obtaining an incident field strength at a predetermined wavelength at an occulter surface; obtaining a field propagation from the occulter to the telescope aperture using a Fresnel integral; modeling a celestial object at differing field angles by shifting a location of a shadow cast by the occulter on the telescope aperture; calculating an intensity of the occulter shadow on the telescope aperture; and applying a telescope aperture mask to a field of the occulter shadow, and propagating the light to a focal plane of the telescope via FFT techniques.

  9. [Progress in research of occult hepatitis B virus infection].

    PubMed

    Huang, X Y; Shi, Q F; Huang, T

    2017-05-10

    Occult hepatitis B virus infection is a worldwide public health problem, which seriously affects the clinical diagnosis of hepatitis B and threatens the safety of blood transfusion. The concept of occult hepatitis B virus infection, the pathogenesis of occult hepatitis B virus infection, the prevalence of occult hepatitis B virus infection in different groups, including healthy population and different patients, and the possibility of transmission were summarized. The prevalence of occult hepatitis B virus infection was found in healthy population and different patients, and there is possibility of occult hepatitis B virus infection to be transmitted through blood transfusion. The paper provides a comprehensive introduction of the pathogenesis and prevalence of occult hepatitis B virus infection. More attention should be paid to occult hepatitis B virus infection.

  10. Occultation studies of the Solar System

    NASA Technical Reports Server (NTRS)

    Millis, Robert L.

    1987-01-01

    The planetary occultation program began at Lowell Observatory in 1973 with a worldwide campaign to observe mutual occultations and eclipses of the Galilean Satellites. Then the temperature profile of the Martian atmosphere was measured from data taken during the occultation of epsilon Geminorum, the Rings of Uranus were discovered as they occulted SAO 158687, and the dimensions of Pallas were measured when that minor planet occulted SAO 85009. In 1979 the present grant was initiated, providing funds for portable photometric instrumentation used to observe occultations by asteroids as well as by Uranus and Neptune. Software for predicting occultations of catalog stars by asteroids, planets, and comets was written in 1983. Lowell currently provides most of the available predictions for asteroid occultations. Realizing in 1983 that the lack of a high-quality astrometric telescope dedicated to occultation work was limiting progress, an 18-inch, F/8 lens was acquired and adapted to an existing mounting at Lowell. Although acquisition of the lens and implementation of the new telescope has been accomplished primarily with non-grant funds, the instrument makes a major contribution to occultation research.

  11. Magnitudes of selected stellar occultation candidates for Pluto and other planets, with new predictions for Mars and Jupiter

    NASA Technical Reports Server (NTRS)

    Sybert, C. B.; Bosh, A. S.; Sauter, L. M.; Elliot, J. L.; Wasserman, L. H.

    1992-01-01

    Occultation predictions for the planets Mars and Jupiter are presented along with BVRI magnitudes of 45 occultation candidates for Mars, Jupiter, Saturn, Uranus, and Pluto. Observers can use these magnitudes to plan observations of occultation events. The optical depth of the Jovian ring can be probed by a nearly central occultation on 1992 July 8. Mars occults an unusually red star in early 1993, and the occultations for Pluto involving the brightest candidates would possibly occur in the spring of 1992 and the fall of 1993.

  12. Association of preS/S Mutations with Occult Hepatitis B Virus (HBV) Infection in South Korea: Transmission Potential of Distinct Occult HBV Variants

    PubMed Central

    Kim, Hong; Kim, Bum-Joon

    2015-01-01

    Occult hepatitis B virus infection (HBV) is characterized by HBV DNA positivity but HBV surface antigen (HBsAg) negativity. Occult HBV infection is associated with a risk of HBV transmission through blood transfusion, hemodialysis, and liver transplantation. Furthermore, occult HBV infection contributes to the development of cirrhosis and hepatocellular carcinoma. We recently reported the characteristic molecular features of mutations in the preS/S regions among Korean individuals with occult infections caused by HBV genotype C2; the variants of preS and S related to severe liver diseases among chronically infected patients were also responsible for the majority of HBV occult infections. We also reported that HBsAg variants from occult-infected Korean individuals exhibit lower HBsAg secretion capacity but not reduced HBV DNA levels. In addition, these variants exhibit increased ROS-inducing capacity compared with the wild-type strain, linking HBV occult infections to liver cell damage. Taken together, our previous reports suggest the transmission potential of distinct HBV occult infection-related variants in South Korea. PMID:26084041

  13. Association of preS/S Mutations with Occult Hepatitis B Virus (HBV) Infection in South Korea: Transmission Potential of Distinct Occult HBV Variants.

    PubMed

    Kim, Hong; Kim, Bum-Joon

    2015-06-15

    Occult hepatitis B virus infection (HBV) is characterized by HBV DNA positivity but HBV surface antigen (HBsAg) negativity. Occult HBV infection is associated with a risk of HBV transmission through blood transfusion, hemodialysis, and liver transplantation. Furthermore, occult HBV infection contributes to the development of cirrhosis and hepatocellular carcinoma. We recently reported the characteristic molecular features of mutations in the preS/S regions among Korean individuals with occult infections caused by HBV genotype C2; the variants of preS and S related to severe liver diseases among chronically infected patients were also responsible for the majority of HBV occult infections. We also reported that HBsAg variants from occult-infected Korean individuals exhibit lower HBsAg secretion capacity but not reduced HBV DNA levels. In addition, these variants exhibit increased ROS-inducing capacity compared with the wild-type strain, linking HBV occult infections to liver cell damage. Taken together, our previous reports suggest the transmission potential of distinct HBV occult infection-related variants in South Korea.

  14. A search for stellar occultations by Uranus, Neptune, Pluto, and their satellites: 1990-1999

    NASA Technical Reports Server (NTRS)

    Mink, Douglas J.

    1991-01-01

    A search for occultations of stars by Uranus, Neptune, and Pluto between 1990 and 1999 was carried out by combining ephemeris information and star positions using very accurate occultation modeling software. Stars from both the Space Telescope Guide Catalog and photographic plates taken by Arnold Klemola at Lick Observatory were compared with planet positions from the JPL DE-130 ephemeris, with local modifications for Pluto and Charon. Some 666 possible occultations by the Uranian ring, 143 possible occultations by Neptune, and 40 possible occultations by Pluto and/or Charon were found among stars with visual magnitudes as faint as 16. Before the star positions could be obtained, the occultation prediction software was used to aid many observers in observing the occultation of 28 Sagitarii by Saturn in July 1989. As a test on other outer solar system objects, 17 possible occultations were found in a search of the Guide Star Catalog for occultations by 2060 Chiron, and interesting object between Saturn and Uranus which shows both cometary and asteroidal properties.

  15. A search for stellar occultations by Uranus, Neptune, Pluto, and their satellites: 1990-1999

    NASA Astrophysics Data System (ADS)

    Mink, Douglas J.

    1991-03-01

    A search for occultations of stars by Uranus, Neptune, and Pluto between 1990 and 1999 was carried out by combining ephemeris information and star positions using very accurate occultation modeling software. Stars from both the Space Telescope Guide Catalog and photographic plates taken by Arnold Klemola at Lick Observatory were compared with planet positions from the JPL DE-130 ephemeris, with local modifications for Pluto and Charon. Some 666 possible occultations by the Uranian ring, 143 possible occultations by Neptune, and 40 possible occultations by Pluto and/or Charon were found among stars with visual magnitudes as faint as 16. Before the star positions could be obtained, the occultation prediction software was used to aid many observers in observing the occultation of 28 Sagitarii by Saturn in July 1989. As a test on other outer solar system objects, 17 possible occultations were found in a search of the Guide Star Catalog for occultations by 2060 Chiron, and interesting object between Saturn and Uranus which shows both cometary and asteroidal properties.

  16. Progress on the occulter experiment at Princeton

    NASA Astrophysics Data System (ADS)

    Cady, Eric; Balasubramanian, Kunjithapatham; Carr, Michael; Dickie, Matthew; Echternach, Pierre; Groff, Tyler; Kasdin, Jeremy; Laftchiev, Christian; McElwain, Michael; Sirbu, Dan; Vanderbei, Robert; White, Victor

    2009-08-01

    An occulter is used in conjunction with a separate telescope to suppress the light of a distant star. To demonstrate the performance of this system, we are building an occulter experiment in the laboratory at Princeton. This experiment will use an etched silicon mask as the occulter, with some modifications to try to improve the performance. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. We present the progress of this experiment and expectations for future work.

  17. Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding

    NASA Technical Reports Server (NTRS)

    Hagopian, John; Lyon, Richard; Shiri, Shahram; Roman, Patrick

    2011-01-01

    Advanced formation flying occulter designs utilize a large occulter mask flying in formation with an imaging telescope to block and null starlight to allow imaging of faint planets in exosolar systems. A paper describes the utilization of subscale reflective occultation masks to evaluate formation flying occulter designs. The use of a reflective mask allows mounting of the occulter by conventional means and simplifies the test configuration. The innovation alters the test set-up to allow mounting of the mask using standard techniques to eliminate the problems associated with a standard configuration. The modified configuration uses a reflective set-up whereby the star simulator reflects off of a reflective occulting mask and into an evaluation telescope. Since the mask is sized to capture all rays required for the imaging test, it can be mounted directly to a supporting fixture without interfering with the beam. Functionally, the reflective occultation mask reflects light from the star simulator instead of transmitting it, with a highly absorptive carbon nanotube layer simulating the occulter blocking mask. A subscale telescope images the star source and companion dim source that represents a planet. The primary advantage of this is that the occulter can be mounted conventionally instead of using diffractive wires or magnetic levitation.

  18. Prevalence and Clinical Import of Thoracic Injury Identified by Chest Computed Tomography but Not Chest Radiography in Blunt Trauma: Multicenter Prospective Cohort Study.

    PubMed

    Langdorf, Mark I; Medak, Anthony J; Hendey, Gregory W; Nishijima, Daniel K; Mower, William R; Raja, Ali S; Baumann, Brigitte M; Anglin, Deirdre R; Anderson, Craig L; Lotfipour, Shahram; Reed, Karin E; Zuabi, Nadia; Khan, Nooreen A; Bithell, Chelsey A; Rowther, Armaan A; Villar, Julian; Rodriguez, Robert M

    2015-12-01

    Chest computed tomography (CT) diagnoses more injuries than chest radiography, so-called occult injuries. Wide availability of chest CT has driven substantial increase in emergency department use, although the incidence and clinical significance of chest CT findings have not been fully described. We determine the frequency, severity, and clinical import of occult injury, as determined by changes in management. These data will better inform clinical decisions, need for chest CT, and odds of intervention. Our sample included prospective data (2009 to 2013) on 5,912 patients at 10 Level I trauma center EDs with both chest radiography and chest CT at physician discretion. These patients were 40.6% of 14,553 enrolled in the parent study who had either chest radiography or chest CT. Occult injuries were pneumothorax, hemothorax, sternal or greater than 2 rib fractures, pulmonary contusion, thoracic spine or scapula fracture, and diaphragm or great vessel injury found on chest CT but not on preceding chest radiography. A priori, we categorized thoracic injuries as major (having invasive procedures), minor (observation or inpatient pain control >24 hours), or of no clinical significance. Primary outcome was prevalence and proportion of occult injury with major interventions of chest tube, mechanical ventilation, or surgery. Secondary outcome was minor interventions of admission rate or observation hours because of occult injury. Two thousand forty-eight patients (34.6%) had chest injury on chest radiography or chest CT, whereas 1,454 of these patients (71.0%, 24.6% of all patients) had occult injury. Of these, in 954 patients (46.6% of injured, 16.1% of total), chest CT found injuries not observed on immediately preceding chest radiography. In 500 more patients (24.4% of injured patients, 8.5% of all patients), chest radiography found some injury, but chest CT found occult injury. Chest radiography found all injuries in only 29.0% of injured patients. Two hundred and two patients with occult injury (of 1,454, 13.9%) had major interventions, 343 of 1,454 (23.6%) had minor interventions, and 909 (62.5%) had no intervention. Patients with occult injury included 514 with pulmonary contusions (of 682 total, 75.4% occult), 405 with pneumothorax (of 597 total, 67.8% occult), 184 with hemothorax (of 230 total, 80.0% occult), those with greater than 2 rib fractures (n=672/1,120, 60.0% occult) or sternal fracture (n=269/281, 95.7% occult), 12 with great vessel injury (of 18 total, 66.7% occult), 5 with diaphragm injury (of 6, 83.3% occult), and 537 with multiple occult injuries. Interventions for patients with occult injury included mechanical ventilation for 31 of 514 patients with pulmonary contusion (6.0%), chest tube for 118 of 405 patients with pneumothorax (29.1%), and 75 of 184 patients with hemothorax (40.8%). Inpatient pain control or observation greater than 24 hours was conducted for 183 of 672 patients with rib fractures (27.2%) and 79 of 269 with sternal fractures (29.4%). Three of 12 (25%) patients with occult great vessel injuries had surgery. Repeated imaging was conducted for 50.6% of patients with occult injury (88.1% chest radiography, 11.9% chest CT, 7.5% both). For patients with occult injury, 90.9% (1,321/1,454) were admitted, with 9.1% observed in the ED for median 6.9 hours. Forty-four percent of observed patients were then admitted (4.0% of patients with occult injury). In a more seriously injured subset of patients with blunt trauma who had both chest radiography and chest CT, occult injuries were found by chest CT in 71% of those with thoracic injuries and one fourth of all those with blunt chest trauma. More than one third of occult injury had intervention (37.5%). Chest tubes composed 76.2% of occult injury major interventions, with observation or inpatient pain control greater than 24 hours in 32.4% of occult fractures. Only 1 in 20 patients with occult injury was discharged home from the ED. For these patients with blunt trauma, chest CT is useful to identify otherwise occult injuries. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  19. Fecal Occult Blood Test (FOBT): MedlinePlus Lab Test Information

    MedlinePlus

    ... medlineplus.gov/labtests/fecaloccultbloodtestfobt.html Fecal Occult Blood Test (FOBT) To use the sharing features on this ... enable JavaScript. What is a Fecal Occult Blood Test? A fecal occult blood test (FOBT) looks at ...

  20. Mutations Associated With Occult Hepatitis B in HIV-Positive South Africans

    PubMed Central

    Powell, Eleanor A.; Gededzha, Maemu P.; Rentz, Michael; Rakgole, Nare J.; Selabe, Selokela G.; Seleise, Tebogo A.; Mphahlele, M. Jeffrey; Blackard, Jason T.

    2015-01-01

    Occult hepatitis B is characterized by the absence of hepatitis B surface antigen (HBsAg) but the presence of HBV DNA. Because diagnosis of hepatitis B virus (HBV) typically includes HBsAg detection, occult HBV remains largely undiagnosed. Occult HBV is associated with increased risk of hepatocellular carcinoma, reactivation to chronic HBV during immune suppression, and transmission during blood transfusion and liver transplant. The mechanisms leading to occult HBV infection are unclear, although viral mutations are likely a significant factor. In this study, sera from 394 HIV-positive South Africans were tested for HBV DNA and HBsAg. For patients with detectable HBV DNA, the overlapping surface and polymerase open reading frames (ORFs) were sequenced. Occult-associated mutations—those mutations found exclusively in individuals with occult HBV infection but not in individuals with chronic HBV infection from the same cohort or GenBank references—were identified. Ninety patients (22.8%) had detectable HBV DNA. Of these, 37 had detectable HBsAg, while 53 lacked detectable surface antigen. The surface and polymerase ORFs were cloned successfully for 19 patients with chronic HBV and 30 patients with occult HBV. In total, 235 occult-associated mutations were identified. Ten occult-associated mutations were identified in more than one patient. Additionally, 15 amino acid positions had two distinct occult-associated mutations at the same residue. Occult-associated mutations were common and present in all regions of the surface and polymerase ORFs. Further study is underway to determine the effects of these mutations on viral replication and surface antigen expression in vitro. PMID:25164924

  1. New perspectives in occult hepatitis C virus infection

    PubMed Central

    Carreño, Vicente; Bartolomé, Javier; Castillo, Inmaculada; Quiroga, Juan Antonio

    2012-01-01

    Occult hepatitis C virus (HCV) infection, defined as the presence of HCV RNA in liver and in peripheral blood mononuclear cells (PBMCs) in the absence of detectable viral RNA in serum by standard assays, can be found in anti-HCV positive patients with normal serum levels of liver enzymes and in anti-HCV negative patients with persistently elevated liver enzymes of unknown etiology. Occult HCV infection is distributed worldwide and all HCV genotypes seem to be involved in this infection. Occult hepatitis C has been found not only in anti-HCV positive subjects with normal values of liver enzymes or in chronic hepatitis of unknown origin but also in several groups at risk for HCV infection such as hemodialysis patients or family members of patients with occult HCV. This occult infection has been reported also in healthy populations without evidence of liver disease. Occult HCV infection seems to be less aggressive than chronic hepatitis C although patients affected by occult HCV may develop liver cirrhosis and even hepatocellular carcinoma. Thus, anti-HCV negative patients with occult HCV may benefit from antiviral therapy with pegylated-interferon plus ribavirin. The persistence of very low levels of HCV RNA in serum and in PBMCs, along with the maintenance of specific T-cell responses against HCV-antigens observed during a long-term follow-up of patients with occult hepatitis C, indicate that occult HCV is a persistent infection that is not spontaneously eradicated. This is an updated report on diagnosis, epidemiology and clinical implications of occult HCV with special emphasis on anti-HCV negative cases. PMID:22736911

  2. Mutations associated with occult hepatitis B in HIV-positive South Africans.

    PubMed

    Powell, Eleanor A; Gededzha, Maemu P; Rentz, Michael; Rakgole, Nare J; Selabe, Selokela G; Seleise, Tebogo A; Mphahlele, M Jeffrey; Blackard, Jason T

    2015-03-01

    Occult hepatitis B is characterized by the absence of hepatitis B surface antigen (HBsAg) but the presence of HBV DNA. Because diagnosis of hepatitis B virus (HBV) typically includes HBsAg detection, occult HBV remains largely undiagnosed. Occult HBV is associated with increased risk of hepatocellular carcinoma, reactivation to chronic HBV during immune suppression, and transmission during blood transfusion and liver transplant. The mechanisms leading to occult HBV infection are unclear, although viral mutations are likely a significant factor. In this study, sera from 394 HIV-positive South Africans were tested for HBV DNA and HBsAg. For patients with detectable HBV DNA, the overlapping surface and polymerase open reading frames (ORFs) were sequenced. Occult-associated mutations-those mutations found exclusively in individuals with occult HBV infection but not in individuals with chronic HBV infection from the same cohort or GenBank references-were identified. Ninety patients (22.8%) had detectable HBV DNA. Of these, 37 had detectable HBsAg, while 53 lacked detectable surface antigen. The surface and polymerase ORFs were cloned successfully for 19 patients with chronic HBV and 30 patients with occult HBV. In total, 235 occult-associated mutations were identified. Ten occult-associated mutations were identified in more than one patient. Additionally, 15 amino acid positions had two distinct occult-associated mutations at the same residue. Occult-associated mutations were common and present in all regions of the surface and polymerase ORFs. Further study is underway to determine the effects of these mutations on viral replication and surface antigen expression in vitro. © 2014 Wiley Periodicals, Inc.

  3. Predicted occultation of Regulus

    NASA Astrophysics Data System (ADS)

    Waagen, Elizabeth O.

    2014-03-01

    The predicted occultation of Regulus (alpha Leo) by the magnitude-12.4 V asteroid (163) Erigone on 2014 March 20 at approximately 02:06 a.m. EDT (06:06 UT) is discussed. The occultation track includes Bermuda and northwest along a corridor stretching from the mid-Atlantic USA through Ontario, Canada. Unusual things about this occultation include the facts that the track includes major metropolitan areas such as New York City, and the star being occulted is one of the brightest in the Northern sky and is in a constellation pattern that makes it easy to find. The International Occultation Timing Association (IOTA) website (http://occultations.org/Regulus2014/) has comprehensive information about this predicted occultation and observing and reporting instructions, as well as links to other resources. In addition to witnessing a very rare event (Regulus is the brightest star ever to be predicted to be occulted from the USA), the possibilities for science include these three:! determining the shape of Erigone, detecting a possible companion of Erigone, and detecting the suspected white dwarf companion of Regulus. See the Alert Notice for details.

  4. Occult hepatitis B virus infection in hematopoietic stem cell donors in a hepatitis B virus endemic area.

    PubMed

    Hui, Chee-kin; Sun, Jian; Au, Wing-yan; Lie, Albert K W; Yueng, Yui-hung; Zhang, Hai-ying; Lee, Nikki P; Hou, Jin-ling; Liang, Raymond; Lau, George K K

    2005-06-01

    The acquisition of hepatitis B virus (HBV) infection following organ transplantation from donors with occult HBV infection is an important cause of morbidity and mortality. The aim of this study is to determine the prevalence of occult HBV in allogeneic hematopoietic stem cell (HSC) transplantation donors. We performed a retrospective study on 124 consecutive hepatitis B surface antigen negative HSC donors. Their serum samples were analyzed by PCR for the pre-S/S, pre-core/core and X regions of the virus. Samples reactive by at least two PCR assays were considered HBV-DNA positive. Nineteen of the 124 HSC donors (15.3%) had occult HBV infection. Sixteen of these 19 donors with occult HBV infection (84.2%) tested positive for hepatitis B core antibody while 78 of 105 subjects (74.3%) without occult HBV infection were also positive (P=0.56). Fourteen of the 19 donors (73.7%) with occult HBV infection tested positive for hepatitis B surface antibody while 67 of the 105 subjects without occult HBV infection were also positive (P=0.45). The prevalence of occult HBV infection among HSC donors in Hong Kong is high. Anti-HBc and anti-HBs status had no significant correlation with the presence of occult HBV infection.

  5. The Northrop Grumman External Occulter Testbed: Preliminary Results

    NASA Astrophysics Data System (ADS)

    Lo, Amy; Glassman, T.; Lillie, C.

    2007-05-01

    We have built a subscale testbed to demonstrate and validate the performance of the New Worlds Observer (NWO), a terrestrial planet finder external-occulter mission concept. The external occulter concept allows observations of nearby exo-Earths using two spacecraft: one carrying an occulter that is tens of meters in diameter and the other carrying a generic space telescope. The occulter is completely opaque, resembling a flower, with petals having a hypergaussian profile that enable 10-10 intensity suppression of stars that potentially harbor terrestrial planets. The baseline flight NWO system has a 30 meter occulter flying 30,000 km in front of a 4 meter class telescope. Testing the flight configuration on the ground is not feasible, so we have matched the Fresnel number of the flight configuration ( 10) using a subscale occulter. Our testbed consists of an 80 meter length evacuated tube, with a high precision occulter in the center of the tube. The occulter is 4 cm in diameter, manufactured with ¼ micron metrological accuracy and less than 2 micron tip truncation. This mimics a 30 meter occulter with millimeter figure accuracy and less than centimeter tip truncation. Our testbed is an evolving experiment, and we report here the first, preliminary, results using a single wavelength laser (532 nm) as the source.

  6. Occult Participation: Its Impact on Adolescent Development.

    ERIC Educational Resources Information Center

    Tennant-Clark, Cynthia M.; And Others

    1989-01-01

    Investigated relationship between occult participation, substance abuse, and level of self-esteem among 25 clinical (alcohol or drug treatment) and 25 nonclinical adolescents. Results indicated that adolescent substance abuse and occult participation were significantly related. Found significant differences between high versus low occult groups…

  7. All-Sky Earth Occultation Observations with the Fermi Gamma-Ray Burst Monitor

    NASA Technical Reports Server (NTRS)

    Wilson-Hodge, C. A.; Beklen, E.; Bhat, P. N.; Briggs, M.; Camero-Arranz, A.; Case, G.; Jenke, P.; Chaplin, V.; Cherry, M.; Connaughton, V.; hide

    2009-01-01

    Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/ soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. In addition, to Earth occultations, we have observed numerous occultations with Fermi's solar panels.

  8. Image Analysis of the 2012 Pluto (Near) Occultation

    DTIC Science & Technology

    2013-09-01

    Image Analysis of the 2012 Pluto (Near) Occultation Keith T. Knox Air Force Research Laboratory ABSTRACT Imagery was gathered at the AMOS...observatory on the 3.6-meter telescope for the expected occultation of a star by the dwarf planet, Pluto , on 29 June 2012. The imagery was taken at...5 Hz for 40 minutes before and after the expected time of occultation. The initial analysis of the photometry indicated that Pluto did not occult

  9. Observation and Interpretation of Lunar Occultations. Ph.D. Thesis; [Uranus and beta Capricorni

    NASA Technical Reports Server (NTRS)

    Radick, R. R.

    1978-01-01

    The importance of timings and high resolution astrometry in occultation observations is discussed as well as the occultation process itself. The design and operation of the telescope, photodetector, and data acquisition systems are described. Methods are presented for data analysis and model fitting. Observations of beta Capricorni and Uranus occultations are examined. General conclusions concerning occultation observations are explored and future activities at Prairie Observatory are discussed.

  10. All-Sky Earth Occultation Observations with the Fermi Gamma Ray Burst Monitor

    NASA Technical Reports Server (NTRS)

    Wilson-Hodge, C. A.; Beklen, E.; Bhat, P. N.; Briggs, M.; Camero-Arranz, A.; Case, G.; Chaplin, V.; Cherry, M.; Connaughton, V.; Finger, M.; hide

    2010-01-01

    Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. New sources are added to our catalog as they become active or upon request. In addition to Earth occultations, we have observed numerous occultations with Fermi's solar panels. We will present early results. Regularly updated results will be found on our website http://gammaray.nsstc.nasa.gov/gbm/science/occultation.

  11. Molecular Mechanisms Underlying Occult Hepatitis B Virus Infection

    PubMed Central

    Samal, Jasmine; Kandpal, Manish

    2012-01-01

    Summary: Chronic hepatitis B virus (HBV) infection is a complex clinical entity frequently associated with cirrhosis and hepatocellular carcinoma (HCC). The persistence of HBV genomes in the absence of detectable surface antigenemia is termed occult HBV infection. Mutations in the surface gene rendering HBsAg undetectable by commercial assays and inhibition of HBV by suppression of viral replication and viral proteins represent two fundamentally different mechanisms that lead to occult HBV infections. The molecular mechanisms underlying occult HBV infections, including recently identified mechanisms associated with the suppression of HBV replication and inhibition of HBV proteins, are reviewed in detail. The availability of highly sensitive molecular methods has led to increased detection of occult HBV infections in various clinical settings. The clinical relevance of occult HBV infection and the utility of appropriate diagnostic methods to detect occult HBV infection are discussed. The need for specific guidelines on the diagnosis and management of occult HBV infection is being increasingly recognized; the aspects of mechanistic studies that warrant further investigation are discussed in the final section. PMID:22232374

  12. Occult cancer-related first venous thromboembolism is associated with an increased risk of recurrent venous thromboembolism.

    PubMed

    Gran, O V; Braekkan, S K; Paulsen, B; Skille, H; Rosendaal, F R; Hansen, J-B

    2017-07-01

    Essentials Recurrence risk after an occult cancer-related incident venous thromboembolism (VTE) is unknown. We compared the risk of VTE recurrence in occult-, overt- and non-cancer related first VTE. Patients with occult-cancer related first VTE had the highest risk of VTE recurrence. The high recurrence risk in occult cancer is likely due to the advanced cancers. Background Although venous thromboembolism (VTE) is associated with a high recurrence rate, the absolute recurrence rates for cancer-related VTE, particularly occult cancer, are not well known. Objectives To investigate the risk of VTE recurrence in patients with occult and overt cancer-related VTE. Methods Incident VTE events among participants of the first to sixth Tromsø surveys occurring in the period 1994-2012 were included. Occult cancer was defined as cancer diagnosed within a year following a VTE, and overt cancer was defined as cancer diagnosed within the 2 years before a VTE. Results Among 733 patients with incident VTE, 110 had overt cancer and 40 had occult cancer. There were 95 recurrent VTE events during a median of 3.2 years of follow-up. The 1-year cumulative incidence of VTE recurrence was 38.6% in subjects with occult cancer, 15.5% in subjects with overt cancer, and 3.8% in non-cancer subjects. The 1-year risk of recurrence was 12-fold (hazard ratio [HR] 12.4, 95% confidence interval [CI] 5.9-26.3) higher in subjects with occult cancer and four-fold (HR 4.3, 95% CI 2.0-9.2) higher in subjects with overt cancer than in non-cancer subjects. The occult cancers associated with VTE recurrence were typically located at prothrombotic sites (i.e. lung and gastrointestinal) and presented at advanced stages. The majority (69%) of recurrences in subjects with occult cancer occurred before or shortly after cancer diagnosis, and were therefore not treatment-related. Conclusion Our findings suggest that the increased risk of recurrence in patients with occult cancer is mainly attributable to the advanced cancers in these patients. © 2017 International Society on Thrombosis and Haemostasis.

  13. Several Well-observed Asteroidal Occultations in 2010

    NASA Astrophysics Data System (ADS)

    Timerson, Brad; Durech, J.; Abramson, H.; Brooks, J.; Caton, D.; Clark, D.; Conard, S.; Cooke, B.; Dunham, D. W.; Dunham, J.; Edberg, S.; Ellington, C.; Faircloth, J.; Herchak, S.; Iverson, E.; Jones, R.; Lucas, G.; Lyzenga, G.; Maley, P.; Martinez, L.; Menke, J.; Mroz, G.; Nolan, P.; Peterson, R.; Preston, S.; Rattley, G.; Ray, J.; Scheck, A.; Stamm, J.; Stanton, R.; Suggs, R.; Tatum, R.; Thomas, W.

    2011-10-01

    During 2010 IOTA observers in North America reported about 190 positive observations for 106 asteroid occultation events. For several asteroids, this included observations with multiple chords. For two events, an inversion model was available. An occultation by 16 Psyche on 2010 August 21 yielded a best-fit ellipse of 235.4 x 230.4 km. On 2010 December 24, an occultation by 93 Minerva produced a best-fit ellipse of 179.4 x 133.4 km. An occultation by 96 Aegle on 2010 October 29 yielded a best-fit ellipse of 124.9 x 88.0 km. An occultation by 105 Artemis on 2010 June 24 showed a best-fit ellipse of 125.0 x 92.0 km. An occultation by 375 Ursula on 2010 December 4 produced a best-fit ellipse of 125.0 km x 135.0 km. Of note are two events not summarized in this article. On 2010 August 31, an occultation by 695 Bella yielded a new double star. That event will be summarized in the JDSO. Finally, on 2010 April 6, an occultation of zeta Ophiuchi by 824 Anastasia was observed by 65 observers at 69 locations. Unfortunately a large shift in the path yielded only 4 chords. Results of that event, and all the events mentioned here, can be found on the North American Asteroidal Occultation Results web page.

  14. ASTEROID SIZING BY RADIOGALAXY OCCULTATION AT 5 GHZ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehtinen, K.; Muinonen, K.; Poutanen, M.

    Stellar occultations by asteroids observed at visual wavelengths have been an important tool for studying the size and shape of asteroids and for revising the orbital parameters of asteroids. At radio frequencies, a shadow of an asteroid on the Earth is dominated by diffraction effects. Here, we show, for the first time, that a single observation of an occultation of a compact radio source at a frequency of 5 GHz can be used to derive the effective size of the occulting object and to derive the distance between the observer and the center of the occultation path on the Earth.more » The derived diameter of the occulting object, asteroid (115) Thyra, is 75 ± 6 km. The observed occultation profile shows features that cannot be explained by diffraction of a single asteroid.« less

  15. Diagnostic accuracy of oblique chest radiograph for occult pneumothorax: comparison with ultrasonography.

    PubMed

    Matsumoto, Shokei; Sekine, Kazuhiko; Funabiki, Tomohiro; Orita, Tomohiko; Shimizu, Masayuki; Hayashida, Kei; Kazamaki, Taku; Suzuki, Tatsuya; Kishikawa, Masanobu; Yamazaki, Motoyasu; Kitano, Mitsuhide

    2016-01-01

    An occult pneumothorax is a pneumothorax that is not seen on a supine chest X-ray but is detected by computed tomography scanning. However, critical patients are difficult to transport to the computed tomography suite. We previously reported a method to detect occult pneumothorax using oblique chest radiography (OXR). Several authors have also reported that ultrasonography is an effective technique for detecting occult pneumothorax. The aim of this study was to evaluate the usefulness of OXR in the diagnosis of the occult pneumothorax and to compare OXR with ultrasonography. All consecutive blunt chest trauma patients with clinically suspected pneumothorax on arrival at the emergency department were prospectively included at our tertiary-care center. The patients underwent OXR and ultrasonography, and underwent computed tomography scans as the gold standard. Occult pneumothorax size on computed tomography was classified as minuscule, anterior, or anterolateral. One hundred and fifty-nine patients were enrolled. Of the 70 occult pneumothoraces found in the 318 thoraces, 19 were minuscule, 32 were anterior, and 19 were anterolateral. The sensitivity and specificity of OXR for detecting occult pneumothorax was 61.4 % and 99.2 %, respectively. The sensitivity and specificity of lung ultrasonography was 62.9 % and 98.8 %, respectively. Among 27 occult pneumothoraces that could not be detected by OXR, 16 were minuscule and 21 could be conservatively managed without thoracostomy. OXR appears to be as good method as lung ultrasonography in the detection of large occult pneumothorax. In trauma patients who are difficult to transfer to computed tomography scan, OXR may be effective at detecting occult pneumothorax with a risk of progression.

  16. Radio occultation experiments with INAF-IRA radiotelescopes.

    NASA Astrophysics Data System (ADS)

    Pluchino, S.; Schillirò, F.; Salerno, E.; Pupillo, G.

    The Radio Occultation research program performed at the Medicina and Noto Radioastronomical Stations of the Istituto Nazionale di Astrofisica (INAF) - Istituto di Radioastronomia (IRA) includes observations of spacecraft by satellite and satellite by satellite events. The Lunar Radio Occultation (LRO) part of the program consists in collecting data of the lunar Total Electron Content (TEC), at different limb longitudes and at different time, in order to study long term variation of the Moon's ionosphere. The LRO program started at Medicina in September 2006 with the observation of the European probe SMART-1 during its impact on the lunar soil. It proceeded in 2007 with the observation of the lunar occultations of Saturn and Venus, and with the observation of Mars in 2008. On this occasion the probes Cassini, Venus Express, Mars Express, Mars Reconaissance Orbiter and Mars Odissey were respectively occulted by the moon. On Dec 1st 2008 a Venus lunar occultation occurred. On that occasion we performed the first Italian-VLBI (I-VLBI) tracking experiment by detecting the carrier signals coming from the Venus Express (VEX) spacecraft with both the IRA radiotelescopes together with the Matera antenna of the Italian Space Agency. The second part of the radio occultation program includes the observation of satellite by satellite occultation events, as well as mutual occultations of Jupiter satellites. These events are referred to as mutual phenomena (PHEMU). These observations are aimed to measure the radio flux variation during the occultation and to derive surface spatial characteristics such as Io's hot spots. In this work preliminary results of the Radio Occultation program will be presented.

  17. The Occult Today: Why?

    ERIC Educational Resources Information Center

    Kessler, Gary E.

    1975-01-01

    Author offered some reflections on the "why" of the contemporary interest in the occult. He attempted to convince the reader that, if he or she has been surprised by the recent rise of occultism, sober reflection will dispell some fears and, perhaps, even convince him or her that occultism is not merely superstition. (Author/RK)

  18. Exploring the Solar System with Stellar Occultations

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Dunham, E. W.

    1984-01-01

    By recording the light intensity as a function of time when a planet occults a relatively bright star, the thermal structure of the upper atmosphere of the planet can be probed. The main feature of stellar occultation observations is their high spatial resolution, typically several thousand times better than the resolution achievable with ground-based imaging. Five stellar occultations have been observed. The main results of these observations are summarized. Stellar occultations have been observed on Uranus, Mars, Pallas, Neptune and the Jovian Ring.

  19. Stellar occultation studies of the solar system

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.

    1979-01-01

    The paper covers the principles, observational procedures, and results relating to occultations of stars by solar system bodies other than the moon. Physical processes involved in occultations are presented including (1) extinction by ring material, (2) differential refraction by a planetary atmosphere, (3) extinction by a planetary atmosphere, and (4) Fresnel diffraction by sharp edges. It is noted that from a sufficient number of immersion and emersion timings of a stellar occultation, the radius and ellipticity of the occulting body can be accurately determined. From an occultation by a planet having an atmosphere, temperature, pressure, and number density profiles can be obtained along with information about the composition of the atmosphere and the extinction.

  20. Triton stellar occultation candidates - 1992-1994

    NASA Technical Reports Server (NTRS)

    Mcdonald, S. W.; Elliot, J. T.

    1992-01-01

    A search for Triton stellar occultation candidates for the period 1992-1994 has been completed with CCD strip-scanning observations. The search reached an R magnitude of about 17.4 and found 129 candidates within 1.5 arcsec of Triton's ephemeris during this period. Of these events, around 30 occultations are expected to be visible from the earth, indicating that a number of Triton occultation events should be visible from major observatories. Even the faintest of the present candidate events could produce useful occultation data if observed with a large enough telescope. The present astrometric accuracy is inadequate to identify which of these appulse events will produce occultations on the earth; further astrometry is needed to refine the predictions for positive occultation identification. To aid in selecting candidates for additional astrometric and photometric studies, finder charts and earth-based visibility charts for each event are included.

  1. Radiologically occult medulloblastoma with hydrocephalus: case report.

    PubMed

    Honma, Hirokuni; Ogiwara, Hideki

    2017-09-01

    There have been no reports of occult medulloblastoma nor noncommunicating hydrocephalus due to radiologically occult brain tumors. Herein, we report radiologically occult medulloblastoma with noncommunicating hydrocephalus. A 3-year-old boy presented with macrocephaly, visual field constriction, and papilledema. Neuroimagings showed enlargement of the ventricles without any mass lesions. The CT cisternography did not show influx of the contrast into the ventricles, which suggested local cerebrospinal fluid (CSF) circulatory disturbance at the outlet of the fourth ventricle. Due to possible obstructive nature of hydrocephalus, endoscopic third ventriculostomy (ETV) was performed. Three months after the ETV, he presented with repeated vomiting. Neuroimagings showed a 3-cm fourth ventricular mass with progressive hydrocephalus. Surgical resection was performed, which revealed the pathology was medulloblastoma. We report the case of radiologically occult medulloblastoma which was demonstrated radiologically in the follow-up period of ETV for noncommunicating hydrocephalus of uncertain etiology. This is the first description of a radiologically occult medulloblastoma and also the first description of an occult brain tumor with noncommunicating hydrocephalus. The occult brain tumor may be included in the etiology of hydrocephalus.

  2. Naturally Occurring Mutations in Large Surface Genes Related to Occult Infection of Hepatitis B Virus Genotype C

    PubMed Central

    Kim, Hong; Lee, Seoung-Ae; Kim, Dong-Won; Lee, Sueng-Hyun; Kim, Bum-Joon

    2013-01-01

    Molecular mechanisms related to occult hepatitis B virus (HBV) infection, particularly those based on genotype C infection, have rarely been determined thus far in the ongoing efforts to determine infection mechanisms. Therefore, we aim to elucidate the mutation patterns in the surface open reading frame (S ORF) underlying occult infections of HBV genotype C in the present study. Nested PCRs were applied to 624 HBV surface antigen (HBsAg) negative Korean subjects. Cloning and sequencing of the S ORF gene was applied to 41 occult cases and 40 control chronic carriers. Forty-one (6.6%) of the 624 Korean adults with HBsAg-negative serostatus were found to be positive for DNA according to nested PCR tests. Mutation frequencies in the three regions labeled here as preS1, preS2, and S were significantly higher in the occult subjects compared to the carriers in all cases. A total of two types of deletions, preS1 deletions in the start codon and preS2 deletions as well as nine types of point mutations were significantly implicated in the occult infection cases. Mutations within the “a” determinant region in HBsAg were found more frequently in the occult subjects than in the carriers. Mutations leading to premature termination of S ORF were found in 16 occult subjects (39.0%) but only in one subject from among the carriers (2.5%). In conclusion, our data suggest that preS deletions, the premature termination of S ORF, and “a” determinant mutations are associated with occult infections of HBV genotype C among a HBsAg-negative population. The novel mutation patterns related to occult infection introduced in the present study can help to broaden our understanding of HBV occult infections. PMID:23349904

  3. Characterization of the occult nature of injury for frequently occurring motor vehicle crash injuries.

    PubMed

    Schoell, Samantha L; Doud, Andrea N; Weaver, Ashley A; Talton, Jennifer W; Barnard, Ryan T; Winslow, James E; Stitzel, Joel D

    2017-01-01

    Occult injuries are not easily detected and can be potentially life-threatening. The purpose of this study was to quantify the perceived occultness of the most frequent motor vehicle crash injuries according to emergency medical services (EMS) professionals. An electronic survey was distributed to 1,125 EMS professionals who were asked to quantify the likelihood that first responders would miss symptoms related to a particular injury on a 5-point Likert scale. The Occult Score for each injury was computed from the average of all the survey responses and normalized to be a continuous metric ranging from 0 to 1 where 0 is a non-occult (highly apparent on initial presentation) injury and 1 is an occult (unapparent on initial presentation) injury. Overall, 110,671 survey responses were collected. The Occult Score ranged from 0 to 1 with a mean, median, and standard deviation of 0.443, 0.450, and 0.233, respectively. When comparing the Occult Score of an injury to its corresponding AIS severity, there was no relationship between the metrics. When stratifying by body region, injury type, and AIS severity, it was evident that AIS 2-4 abdominal injuries with lacerations, hemorrhage, or contusions were perceived as the most occult injuries. Timely triage is key to reduce the morbidity and mortality associated with occult injuries. The Occult Score developed in this study to describe the predictability of an injury in a motor vehicle crash will be used as part of a larger effort, including incorporation into an advanced automatic crash notification (AACN) algorithm to detect crash conditions associated with a patient's need for prompt treatment at a trauma center. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Prevalence of large and occult pneumothoraces in patients with severe blunt trauma upon hospital admission: experience of 526 cases in a French level 1 trauma center.

    PubMed

    Charbit, Jonathan; Millet, Ingrid; Maury, Camille; Conte, Benjamin; Roustan, Jean-Paul; Taourel, Patrice; Capdevila, Xavier

    2015-06-01

    Occult pneumothoraces (PTXs), which are not visible on chest x-ray, may progress to tension PTX. The aim of study was to establish the prevalence of large occult PTXs upon admission of patients with severe blunt trauma, according to prehospital mechanical ventilation. Patients with severe trauma consecutively admitted to our institution for 5 years were retrospectively analyzed. All patients with blunt thoracic trauma who had undergone computed tomographic (CT) within the first hour of hospitalization were included. Mechanical ventilation was considered as early if it was introduced in the prehospital period or on arrival at the hospital. Occult PTXs were defined as PTXs not visible on chest x-ray. All PTXs were measured on CT scan (largest thickness and vertical dimension). Large occult PTXs were defined by a largest thickness of 30 mm or more. Of the 526 patients studied, 395 (75%) were male, mean age was 37.9 years, mean Injury Severity Score was 22.2, and 247 (47%) received early mechanical ventilation. Of 429 diagnosed PTXs, 296 (69%) were occult. The proportion of occult PTXs classified as large was 11% (95% confidence interval, 8%-15%). The overall prevalence of large occult PTXs was 6% (95% confidence interval, 4%-8%). Both CT measurements and proportion of large occult PTXs were found statistically comparable in patients with or without mechanical ventilation. Six percent of studied patients with severe trauma had a large and occult PTX as soon as admission despite a normal chest x-ray result. The observed sizes and rates of occult PTX were comparable regardless of the initiation of early mechanical ventilation. Copyright © 2015. Published by Elsevier Inc.

  5. The clinical significance of occult gynecologic primary tumours in metastatic cancer.

    PubMed

    Hannouf, M B; Winquist, E; Mahmud, S M; Brackstone, M; Sarma, S; Rodrigues, G; Rogan, P K; Hoch, J S; Zaric, G S

    2017-10-01

    We estimated the frequency of occult gynecologic primary tumours (gpts) in patients with metastatic cancer from an uncertain primary and evaluated the effect on disease management and overall survival (os). We used Manitoba administrative health databases to identify all patients initially diagnosed with metastatic cancer during 2002-2011. We defined patients as having an "occult" primary tumour if the primary was classified at least 6 months after the initial diagnosis. Otherwise, we considered patients to have "obvious" primaries. We then compared clinicopathologic and treatment characteristics and 2-year os for women with occult and with obvious gpts. We used Cox regression adjustment and propensity score methods to assess the effect on os of having an occult gpt. Among the 5953 patients diagnosed with metastatic cancer, occult primary tumours were more common in women ( n = 285 of 2552, 11.2%) than in men ( n = 244 of 3401, 7.2%). In women, gpts were the most frequent occult primary tumours ( n = 55 of 285, 19.3%). Compared with their counterparts having obvious gpts, women with occult gpts ( n = 55) presented with similar histologic and metastatic patterns but received fewer gynecologic diagnostic examinations during diagnostic work-up. Women with occult gpts were less likely to undergo surgery, waited longer for radiotherapy, and received a lesser variety of chemotherapeutic agents. Having an occult compared with an obvious gpt was associated with decreased os (hazard ratio: 1.62; 95% confidence interval: 1.2 to 2.35). Similar results were observed in adjusted analyses. In women with metastatic cancer from an uncertain primary, gpts constitute the largest clinical entity. Accurate diagnosis of occult gpts early in the course of metastatic cancer might lead to more effective treatment decisions and improved survival outcomes.

  6. Occult pneumomediastinum in blunt chest trauma: clinical significance.

    PubMed

    Rezende-Neto, J B; Hoffmann, J; Al Mahroos, M; Tien, H; Hsee, L C; Spencer Netto, F; Speers, V; Rizoli, S B

    2010-01-01

    Thoracic injuries are potentially responsible for 25% of all trauma deaths. Chest X-ray is commonly used to screen patients with chest injury. However, the use of computed tomography (CT) scan for primary screening is increasing, particularly for blunt trauma. CT scans are more sensitive than chest X-ray in detecting intra-thoracic abnormalities such as pneumothoraces and pneumomediastinums. Pneumomediastinum detected by chest X-ray or "overt pneumomediastinum", raises the concern of possible aerodigestive tract injuries. In contrast, there is scarce information on the clinical significance of pneumomediastinum diagnosed by CT scan only or "occult pneumomediastinum". Therefore we investigated the clinical consequences of occult pneumomediastinum in our blunt trauma population. A 2-year retrospective chart review of all blunt chest trauma patients with initial chest CT scan admitted to a level I trauma centre. Data extracted from the medical records include; demographics, occult, overt, or no pneumomediastinum, the presence of intra-thoracic aerodigestive tract injuries (trachea, bronchus, and/or esophagus), mechanism and severity of injury, endotracheal intubation, chest thoracostomy, operations and radiological reports by an attending radiologist. All patients with intra-thoracic aerodigestive tract injuries from 1994 to 2004 were also investigated. Of 897 patients who met the inclusion criteria 839 (93.5%) had no pneumomediastinum. Five patients (0.6%) had overt pneumomediastinum and 53 patients (5.9%) had occult pneumomediastinum. Patients with occult pneumomediastinum had significantly higher ISS and AIS chest (p<0.0001) than patients with no pneumomediastinum. A chest thoracostomy tube was more common (p<0.0001) in patients with occult pneumomediastinum (47.2%) than patients with no pneumomediastinum (10.4%), as well as occult pneumothorax. None of the patients with occult pneumomediastinum had aerodigestive tract injuries (95%CI 0-0.06). Follow up CT scan of patients with occult pneumomediastinum showed complete resolution in all cases, in average 3 h after the initial exam. Occult pneumomediastinum occurred in approximately 6% of all trauma patients with blunt chest injuries in our institution. Patients who had occult pneumomediastinum were more severely injured than those who without. However, none of the patients with occult pneumomediastinum had aerodigestive tract injuries and follow up chest CT scans demonstrated their complete and spontaneous resolution.

  7. First light of an external occulter testbed at flight Fresnel numbers

    NASA Astrophysics Data System (ADS)

    Kim, Yunjong; Sirbu, Dan; Hu, Mia; Kasdin, Jeremy; Vanderbei, Robert J.; Harness, Anthony; Shaklan, Stuart

    2017-01-01

    Many approaches have been suggested over the last couple of decades for imaging Earth-like planets. One of the main candidates for creating high-contrast for future Earth-like planets detection is an external occulter. The external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. The occulter is typically tens of meters in diameter and the separation from the telescope is of the order of tens of thousands of kilometers. Optical testing of a full-scale external occulter on the ground is impossible because of the long separations. Therefore, laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we have designed and built a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. The goal of this experiment is to demonstrate a pupil plane suppression of better than 1e-9 with a corresponding image plane contrast of better than 1e-11. The occulter testbed uses a 77.2 m optical propagation distance to realize the flight Fresnel number of 14.5. The scaled mask is placed at 27.2 m from the artificial source and the camera is located 50.0 m from the scaled mask. We will use an etched silicon mask, manufactured by the Microdevices Lab(MDL) of the Jet Propulsion Laboratory(JPL), as the occulter. Based on conversations with MDL, we expect that 0.5 μm feature size is an achievable resolution in the mask manufacturing process and is therefore likely the indicator of the best possible performance. The occulter is illuminated by a diverging laser beam to reduce the aberrations from the optics before the occulter. Here, we present first light result of a sample design operating at a flight Fresnel number and the experimental setup of the testbed. We compare the experimental results with simulations that predict the ultimate contrast performance.

  8. Stellar Occultation Studies of the Solar System

    NASA Technical Reports Server (NTRS)

    Elliot, James L.

    1998-01-01

    Earth-based observations of stellar occultations provide extremely high spatial resolution for bodies in the outer solar system, about 10,000 times better than that of traditional imaging observations. Stellar occultation data can be used to establish the structure of atmospheres and rings of solar system bodies at high spatial resolution. Airborne occultation observations are particularly effective, since the controlled mobility of the observing platform allows the observer to fly within the optimum part of the occultation shadow for most events that are visible from Earth. Airborne observations are carried out above any clouds and are nearly free of scintillation noise from the Earth's atmosphere. KAO occultation observations resulted in the first detection of gravity waves in the Martian atmosphere, discovery of the Uranian rings, the first detection of Pluto's atmosphere, the first Earth-based investigations of Triton's atmosphere, and the discovery of narrow jets from Chiron's nucleus. The first SOFIA occultation opportunity will be an investigation of Pluto's atmospheric structure in November, 2002, and will resolve a problem that has lingered since the KAO discovery observation fourteen years earlier. We plan to continue our successful airborne occultation program with the greatly enhanced capability provided by SOFIA. We propose here to replace our KAO occultation photometer with one having twice the throughput, half the noise, a somewhat wider wavelength range, four times the field of view, and ten times the frame rate to optimize its performance and to capitalize on the larger collecting area offered by SOFIA. It will also allow for simultaneous visible and IR occultation observations, greatly enriching the results that we can obtain from occultations. We call this new imaging occultation photometer HOPI (High-speed Occultation Photometer and Imager). HOPI will provide a signal-to-noise ratio two to four times that of our present photometer for a given event, will permit useful observations of the more numerous events involving fainter stars, and will allow higher time resolution observations to be made. HOPI's characteristics also make it an ideal instrument for initial and ongoing evaluations of the SOFIA telescope's performance.

  9. Morphology and variability of the Titan ringlet and Huygens ringlet edges

    NASA Astrophysics Data System (ADS)

    Jerousek, Richard G.; Colwell, Joshua E.; Esposito, Larry W.

    2011-11-01

    We present a forward modeling approach for determining, in part, the ring particle spatial distribution in the vicinity of sharp ring or ringlet edges. Synthetic edge occultation profiles are computed based on a two-parameter particle spatial distribution model. One parameter, h, characterizes the vertical extent of the ring and the other, δ, characterizes the radial scale over which the ring optical depth transitions from the background ring value to zero. We compare our synthetic occultation profiles to high resolution stellar occultation light curves observed by the Cassini Ultraviolet Imaging Spectrograph (UVIS) High Speed Photometer (HSP) for occultations by the Titan ringlet and Huygens ringlet edges. More than 100 stellar occultations of the Huygens ringlet and Titan ringlet edges were studied, comprising 343 independent occultation cuts of the edges of these two ringlets. In 237 of these profiles the measured light-curve was fit well with our two-parameter edge model. Of the remaining edge occultations, 69 contained structure that could only be fit with extremely large values of the ring-plane vertical thickness ( h > 1 km) or by adopting a different model for the radial profile of the ring optical depth. An additional 37 could not be fit by our two-parameter model. Certain occultations at low ring-plane incidence angles as well as occultations nearly tangent to the ring edge allow the direct measurement of the radial scale over which the particle packing varies at the edge of the ringlet. In 24 occultations with these particular viewing geometries, we find a wide variation in the radial scale of the edge. We are able to constrain the vertical extent of the rings at the edge to less than ˜300 m in the 70% of the occultations with appropriate viewing geometry, however tighter constraints could not be placed on h due to the weaker sensitivity of the occultation profile to vertical thickness compared to its sensitivity to δ. Many occultations of a single edge could not be fit to a single value of δ, indicating large temporal or azimuthal variability, although the azimuthal variation in δ with respect to the longitudes of various moons in the system did not show any discernible pattern.

  10. Predicted occultations by Uranus - 1981-1984

    NASA Technical Reports Server (NTRS)

    Klemola, A. R.; Mink, D. J.; Elliot, J. L.

    1981-01-01

    Predictions are presented for 11 occultations by and appulses to Uranus and its ring system for ten stars from 1981 through 1984. The brightest stars are occulted on April 26, 1981 (BD - 19 deg 4222) and on April 22, 1982 (Hyd - 20 deg 51699). The ring system occults the same star twice during March 1983 (Hyd - 21 deg 64352).

  11. Io hot spots - Infrared photometry of satellite occultations

    NASA Technical Reports Server (NTRS)

    Goguen, J. D.; Matson, D. L.; Sinton, W. M.; Howell, R. R.; Dyck, H. M.

    1988-01-01

    Io's active hot spots, which are presently mapped on the basis of IR photometry of this moon's occultation by other Gallilean satellites, are obtained with greatest spatial resolution near the sub-earth point. A model is developed for the occultation lightcurves, and its fitting to the data defines the apparent path of the occulting satellite relative to Io; the mean error in apparent relative position of occulting satellites is of the order of 178 km. A heretofore unknown, 20-km diameter hot spot is noted on Io's leading hemisphere.

  12. Studies in occultation astronomy

    NASA Technical Reports Server (NTRS)

    Veverka, J.

    1980-01-01

    Major scientific results are summarized for the following studies: (1) observations of the 8 April 1976 occultation of epsilon Geminorum by Mars; (2) studies in occultation techniques; and (3) the March 1974 occultation of Saturn by the Moon. A re-analysis of the 1974 lunar occultation of the Titan indicates that Titan is strongly limb darkened, with D approximately greater than 5800km; there is internal evidence in the data that Titan's atmosphere is inhomogeneous; and that observations are inconsistent with any sample homogeneous model atmosphere which matches the P (lambda) and Beta (lambda) observations of Titan.

  13. Occult pneumothorax in trauma patients: should this be sought in the focused assessment with sonography for trauma examination?

    PubMed

    Tam, Michael M K

    2005-01-01

    At present, CT scan is the gold standard for detecting occult traumatic pneumothorax not apparent on supine chest X-ray radiograph. Recently there were suggestions to expand focused assessment with sonography for trauma (FAST) to include thoracic ultrasound for detecting pneumothorax. The aim of the present study is to determine the incidence of occult pneumothorax (as shown by CT) in the subgroup of trauma patients undergoing FAST. Review of all trauma patients with FAST done from 1 June 2001 to 31 October 2002. Incidence of occult pneumothorax as diagnosed by CT was determined. Patients were not counted as having true occult pneumothorax if they had chest drains inserted before arrival or imaging studies. Selected clinical findings were tested for association with occult pneumothorax. In total, 143 patients underwent FAST, of whom 137 (95.8%) had chest X-ray examination performed. Of the 137 patients 59 required CT abdomen and/or thorax. Occult pneumothorax was found in three patients (2.1%). A history of thorax and/or abdominal injury plus one or more of: (i) mechanisms potentially causing major trauma; (ii) abnormal chest examination; and (iii) chest X-ray radiograph abnormality in the absence of pneumothorax, was significantly associated with the presence of occult pneumothorax (P = 0.03, Fisher's exact test; sensitivity: 100%; specificity: 71%; likelihood ratio: 3.42). The incidence of occult pneumothorax in the subgroup of trauma patients undergoing FAST is low. It implies that routine screening for its presence by adding thoracic ultrasound to FAST is unnecessary. Identifying those at risk of occult pneumothorax for further investigation appeared feasible.

  14. A Digital Video System for Observing and Recording Occultations

    NASA Astrophysics Data System (ADS)

    Barry, M. A. Tony; Gault, Dave; Pavlov, Hristo; Hanna, William; McEwan, Alistair; Filipović, Miroslav D.

    2015-09-01

    Stellar occultations by asteroids and outer solar system bodies can offer ground based observers with modest telescopes and camera equipment the opportunity to probe the shape, size, atmosphere, and attendant moons or rings of these distant objects. The essential requirements of the camera and recording equipment are: good quantum efficiency and low noise; minimal dead time between images; good horological faithfulness of the image timestamps; robustness of the recording to unexpected failure; and low cost. We describe an occultation observing and recording system which attempts to fulfil these requirements and compare the system with other reported camera and recorder systems. Five systems have been built, deployed, and tested over the past three years, and we report on three representative occultation observations: one being a 9 ± 1.5 s occultation of the trans-Neptunian object 28978 Ixion (m v =15.2) at 3 seconds per frame; one being a 1.51 ± 0.017 s occultation of Deimos, the 12 km diameter satellite of Mars, at 30 frames per second; and one being a 11.04 ± 0.4 s occultation, recorded at 7.5 frames per second, of the main belt asteroid 361 Havnia, representing a low magnitude drop (Δm v = ~0.4) occultation.

  15. Occult HBV infection in HIV-infected adults and evaluation of pooled NAT for HBV.

    PubMed

    Dinesha, T R; Boobalan, J; Sivamalar, S; Subashini, D; Solomon, S S; Murugavel, K G; Balakrishnan, P; Smith, D M; Saravanan, S

    2018-06-01

    The study aimed to determine the prevalence of occult hepatitis B virus infection among HIV-infected persons and to evaluate the use of a pooling strategy to detect occult HBV infection in the setting of HIV infection. Five hundred and two HIV-positive individuals were tested for HBV, occult HBV and hepatitis C and D with serologic and nucleic acid testing (NAT). We also evaluated a pooled NAT strategy for screening occult HBV infection among the HIV-positive individuals. The prevalence of HBV infection among HIV-positive individuals was 32 (6.4%), and occult HBV prevalence was 10%. The pooling HBV NAT had a sensitivity of 66.7% and specificity of 100%, compared to HBV DNA NAT of individual samples. In conclusion, this study found a high prevalence of occult HBV infection among our HIV-infected population. We also demonstrated that pooled HBV NAT is highly specific, moderately sensitive and cost-effective. As conventional HBV viral load assays are expensive in resource-limited settings such as India, pooled HBV DNA NAT might be a good way for detecting occult HBV infection and will reduce HBV-associated complications. © 2018 John Wiley & Sons Ltd.

  16. Diffraction-based analysis of tunnel size for a scaled external occulter testbed

    NASA Astrophysics Data System (ADS)

    Sirbu, Dan; Kasdin, N. Jeremy; Vanderbei, Robert J.

    2016-07-01

    For performance verification of an external occulter mask (also called a starshade), scaled testbeds have been developed to measure the suppression of the occulter shadow in the pupil plane and contrast in the image plane. For occulter experiments the scaling is typically performed by maintaining an equivalent Fresnel number. The original Princeton occulter testbed was oversized with respect to both input beam and shadow propagation to limit any diffraction effects due to finite testbed enclosure edges; however, to operate at realistic space-mission equivalent Fresnel numbers an extended testbed is currently under construction. With the longer propagation distances involved, diffraction effects due to the edge of the tunnel must now be considered in the experiment design. Here, we present a diffraction-based model of two separate tunnel effects. First, we consider the effect of tunnel-edge induced diffraction ringing upstream from the occulter mask. Second, we consider the diffraction effect due to clipping of the output shadow by the tunnel downstream from the occulter mask. These calculations are performed for a representative point design relevant to the new Princeton occulter experiment, but we also present an analytical relation that can be used for other propagation distances.

  17. Prospective screening for occult cardiomyopathy in dogs by measurement of plasma atrial natriuretic peptide, B-type natriuretic peptide, and cardiac troponin-I concentrations.

    PubMed

    Oyama, Mark A; Sisson, D David; Solter, Phil F

    2007-01-01

    To evaluate the use of measuring plasma concentrations of atrial natriuretic peptide (ANP), B-type natriuretic peptide (BNP), and cardiac troponin-I (cTnI) to detect dogs with occult dilated cardiomyopathy (DCM). 118 client-owned dogs. Dogs were prospectively examined by use of ECG; echocardiography; and evaluation of concentrations of ANP, BNP, and cTnI. Occult DCM was diagnosed by evaluation of echocardiographic left ventricular dimensions and detection of ventricular arrhythmias on ECG. Sensitivity and specificity of assays for measurement of plasma concentrations of ANP, BNP, and cTnI to detect dogs with occult DCM were determined. Occult DCM was diagnosed in 21 dogs. A concentration of > 6.21 pg/mL for BNP had a sensitivity of 95.2% and specificity of 61.9% for identifying dogs with occult DCM. In contrast, concentrations of ANP and cTnI had relatively low predictive values. Blood-based screening for occult DCM in dogs can be accomplished by use of a BNP assay. Additional studies should be performed to optimize this method of screening dogs to detect occult DCM.

  18. Enabling Narrow(est) IWA Coronagraphy with STIS BAR5 and BAR10 Occulters

    NASA Astrophysics Data System (ADS)

    Schneider, Glenn; Gaspar, Andras; Debes, John; Gull, Theodore; Hines, Dean; Apai, Daniel; Rieke, George

    2017-09-01

    The Space Telescope Imaging Spectrograph's (STIS) BAR5 coronagraphic occulter was designed to provide high-contrast, visible-light, imaging in close (> 0.15") angular proximity to bright point-sources. We explored and verified the functionality and utility of the BAR5 occulter. We also investigated, and herein report on, the use of the BAR10 rounded corners as narrow-angle occulters and compare IWA vs. contrast performance for the BAR5, BAR10, and Wedge occulters. With that, we provide recommendations for the most efficacious BAR5 and BAR10 use on-orbit in support of GO science.

  19. Deep shadow occulter

    NASA Technical Reports Server (NTRS)

    Cash, Webster (Inventor)

    2010-01-01

    Methods and apparatus are disclosed for occulting light. The occulter shape suppresses diffraction at any given size or angle and is practical to build because it can be made binary to avoid scatter. Binary structures may be fully opaque or fully transmitting at specific points. The diffraction suppression is spectrally broad so that it may be used with incoherent white light. An occulter may also include substantially opaque inner portion and an at least partially transparent outer portion. Such occulters may be used on the ground to create a deep shadow in a short distance, or may be used in space to suppress starlight and reveal exoplanets.

  20. High spatial resolution multi-color observations of Neptune during occultation by the moon

    NASA Technical Reports Server (NTRS)

    Veverka, J.

    1976-01-01

    Preparations for the observation of Mars occultation using the 36 inch telescope on a C-141 airborne observatory were described, including technical improvements made to existing equipment. The abstracts of the following four publications supported by the grant were presented: (1) atmosphere composition from refractivity measurements made during occultations, (2) how big is lapetus?, (3) the diameter of Titan, (4) design and operating characteristics of voltage to frequency converters suited for occultation work. The planned observation of the April 8, 1976 occultation of the epsilon Gem star from the C-141 airborne observatory was described.

  1. Overt Skeletal Metastases in a Patient of Occult (Microscopic) Follicular Thyroid Carcinoma: a Rare Case.

    PubMed

    Jha, Chandan Kumar; Agrawal, Vinita; Mishra, Anjali; Pradhan, P K

    2018-03-01

    Occult follicular thyroid carcinoma (FTC) presenting as distant metastases is a rare occurrence. However, despite being occult in majority of these cases, primary tumor can be detected on thyroid imaging or during surgery. Here, we present an extremely rare case of an occult FTC with overt skeletal metastases in which primary tumor was discernible only on microscopic examination.

  2. Exploring small bodies in the outer solar system with stellar occultations

    NASA Technical Reports Server (NTRS)

    Elliot, Jim L.; Dunham, Edward W.; Olkin, C. B.

    1995-01-01

    Stellar occultation observations probe the atmospheric structure and extinction of outer solar system bodies with a spatial resolution of a few kilometers, and an airborne platform allows the observation of occultations by small bodies that are not visible from fixed telescopes. Results from occultations by Triton, Pluto, and Chiron observed with KAO are discussed, and future directions for this program are presented.

  3. First results from stellar occultations in the "GAIA era"

    NASA Astrophysics Data System (ADS)

    Benedetti-Rossi, G.; Vieira-Martins, R.; Sicardy, B.

    2017-09-01

    Stellar occultation is a powerful technique to study distant solar system bodies. It allows high angular resolution of the occulting body from the analysis of a light curve acquired with high temporal resolution with uncertainties comparable as probes. In the "GAIA era", stellar occultations is now able to obtain even more impressive results such as the presence of atmosphere, rings and topographic features.

  4. Sizes, Shapes, and Satellites of Asteroids from Occultations

    NASA Astrophysics Data System (ADS)

    Waring Dunham, David; Herald, David Russell; Preston, Steve; Timerson, Bradley; Maley, Paul; Frappa, Eric; Hayamizu, Tsutomu; Talbot, John; Poro, Atila

    2015-08-01

    For 40 years, the sizes and shapes of dozens of asteroids have been determined from observations of asteroidal occultations. Some of the first evidence for satellites of asteroids was obtained from the early efforts; now, the orbits and sizes of some satellites discovered by other means have been refined from occultation observations. Also, several close binary stars have been discovered, and the angular diameters of some stars have been measured from analysis of these observations. The International Occultation Timing Association (IOTA) coordinates this activity worldwide, from predicting and publicizing the events, to accurately timing the occultations from as many stations as possible, and publishing and archiving the observations.The release of the Hipparcos and Tycho catalogs in 1997, from ESA’s Hipparcos space mission, revolutionized asteroidal occultation work, increasing the routine accuracy of the predictions and the annual number of observations by an order of magnitude. IOTA developed an efficient procedure for predicting the occultations using a combination of new star catalogs, based on Hipparcos and new star catalogs, generated mainly at the U. S. Naval Observatory (USNO), and new observations of asteroids relative to the improved astrometric nets mainly from USNO’s Flagstaff Astrometric Scanning Transit Telescope and JPL’s Table Mountain Observatory. In addition, many IOTA observers now use inexpensive low-light-level video cameras and specially built GPS video time inserters to accurately time the events. This automation has also allowed some observers to deploy multiple remote video stations across occultation paths. Then, one observer can record several “chords” across the asteroid. The cameras are sensitive enough that easily-hidden telescopes, many of which can be packed in standard air travel suitcases, can be used for many of the predicted occultations. IOTA’s network of regional coordinators collect and reduce the observations, which are deposited annually in Asteroid Occultations V12.0. EAR-A-3-RDR-OCCULTATIONS-V12.0. NASA Planetary Data System, 2014, where they are available to researchers worldwide.

  5. Vaginal prolapse repair with or without a midurethral sling in women with genital prolapse and occult stress urinary incontinence: a randomized trial.

    PubMed

    van der Ploeg, J Marinus; Oude Rengerink, Katrien; van der Steen, Annemarie; van Leeuwen, Jules H Schagen; van der Vaart, C Huub; Roovers, Jan-Paul W R

    2016-07-01

    We compared pelvic organ prolapse (POP) repair with and without midurethral sling (MUS) in women with occult stress urinary incontinence (SUI). This was a randomized trial conducted by a consortium of 13 teaching hospitals assessing a parallel cohort of continent women with symptomatic stage II or greater POP. Women with occult SUI were randomly assigned to vaginal prolapse repair with or without MUS. Women without occult SUI received POP surgery. Main outcomes were the absence of SUI at the 12-month follow-up based on the Urogenital Distress Inventory and the need for additional treatment for SUI. We evaluated 231 women, of whom 91 randomized as follows: 43 to POP surgery with and 47 without MUS. A greater number of women in the MUS group reported absence of SUI [86 % vs. 48 %; relative risk (RR) 1.79; 95 % confidence interval (CI) 1.29-2.48]. No women in the MUS group received additional treatment for postoperative SUI; six (13 %) in the control group had a secondary MUS. Women with occult SUI reported more urinary symptoms after POP surgery and more often underwent treatment for postoperative SUI than women without occult SUI. Women with occult SUI had a higher risk of reporting SUI after POP surgery compared with women without occult SUI. Adding a MUS to POP surgery reduced the risk of postoperative SUI and the need for its treatment in women with occult SUI. Of women with occult SUI undergoing POP-only surgery, 13 % needed additional MUS. We found no differences in global impression of improvement and quality of life.

  6. Occult hepatitis B virus infection of hemodialysis patients: a cross-sectional study in a hepatitis B virus-endemic region.

    PubMed

    Kim, So Mi; Kim, Hyun Woo; Lee, Ji Eun; Lee, Eun Kyoung; Shin, Hyun Deok; Song, Il Han

    2015-01-01

    Occult hepatitis B virus (HBV) infection is defined as the presence of HBV DNA in the liver tissue and/or serum of subjects seronegative for hepatitis B surface antigen (HBsAg). Occult HBV infection of hemodialysis (HD) patients is informative in terms of virus transmission, reactivation after kidney transplantation, and the progression of liver disease. However, there is little detailed information about occult HBV infection in the context of virus endemicity. We tried to investigate the seroprevalence and clinical features of occult HBV infection in HD patients in HBV-endemic regions. We enrolled a total of 159 HD patients and 121 apparently healthy subjects at Dankook University Hospital and Jeju National University Hospital in Korea. HBsAg, anti-HBs, anti-HBc, and anti-hepatitis C virus (HCV) antibody levels were measured by radioimmunoassay. Serum levels of HBV DNA were measured by real-time polymerase chain reaction. The seroprevalence of occult HBV infection was 1.3% in HD patients and 2.5% in the healthy controls. This difference was not significant. The HBV load in all subjects with occult infection was <116 copies/mL, and all were positive for IgG anti-HBc, regardless of the presence of anti-HBs. None of the occult HBV-infected subjects were co-infected with HCV. One of the 2 HD patients with occult HBV infection had no history of blood transfusion. In this HBV-endemic region, the seroprevalence of occult HBV infection in HD patients with a very low viral load was not significantly different from that in apparently healthy subjects. © 2014 International Society for Hemodialysis.

  7. The clinical significance of occult gynecologic primary tumours in metastatic cancer

    PubMed Central

    Hannouf, M.B.; Winquist, E.; Mahmud, S.M.; Brackstone, M.; Sarma, S.; Rodrigues, G.; Rogan, P.K.; Hoch, J.S.; Zaric, G.S.

    2017-01-01

    Objective We estimated the frequency of occult gynecologic primary tumours (gpts) in patients with metastatic cancer from an uncertain primary and evaluated the effect on disease management and overall survival (os). Methods We used Manitoba administrative health databases to identify all patients initially diagnosed with metastatic cancer during 2002–2011. We defined patients as having an “occult” primary tumour if the primary was classified at least 6 months after the initial diagnosis. Otherwise, we considered patients to have “obvious” primaries. We then compared clinicopathologic and treatment characteristics and 2-year os for women with occult and with obvious gpts. We used Cox regression adjustment and propensity score methods to assess the effect on os of having an occult gpt. Results Among the 5953 patients diagnosed with metastatic cancer, occult primary tumours were more common in women (n = 285 of 2552, 11.2%) than in men (n = 244 of 3401, 7.2%). In women, gpts were the most frequent occult primary tumours (n = 55 of 285, 19.3%). Compared with their counterparts having obvious gpts, women with occult gpts (n = 55) presented with similar histologic and metastatic patterns but received fewer gynecologic diagnostic examinations during diagnostic work-up. Women with occult gpts were less likely to undergo surgery, waited longer for radiotherapy, and received a lesser variety of chemotherapeutic agents. Having an occult compared with an obvious gpt was associated with decreased os (hazard ratio: 1.62; 95% confidence interval: 1.2 to 2.35). Similar results were observed in adjusted analyses. Conclusions In women with metastatic cancer from an uncertain primary, gpts constitute the largest clinical entity. Accurate diagnosis of occult gpts early in the course of metastatic cancer might lead to more effective treatment decisions and improved survival outcomes. PMID:29089807

  8. Repeated faecal occult blood testing is associated with decreased advanced colorectal cancer risk: A population-based study.

    PubMed

    James, Paul D; Rabeneck, Linda; Yun, Lingsong; Paszat, Lawrence; Baxter, Nancy N; Govindarajan, Anand; Antonova, Lilia; Tinmouth, Jill M

    2017-01-01

    Objective To evaluate the association between repeated faecal occult blood testing and advanced colorectal cancer risk at population level in Canada. Methods A retrospective cohort study of all Ontario residents aged 56-74 diagnosed with colorectal cancer from 1 April 2007 to 31 March 2010, identified using health administrative data. The primary outcome was stage IV colorectal cancer, and primary exposure was faecal occult blood testing use within five years prior to colorectal cancer diagnosis. Patients were categorized into four mutually exclusive groups based on their exposure to faecal occult blood testing in the five years prior to colorectal cancer diagnosis: none, pre-diagnostic, repeated, and sporadic. Logistic regression was utilized to adjust for confounders. Results Of 7753 patients (median age 66, interquartile range 61-70, 62% male) identified, 1694 (22%) presented with stage I, 2056 (27%) with stage II, 2428 (31%) with stage III, and 1575 (20%) with stage IV colorectal cancer. There were 4092 (53%) with no record of prior faecal occult blood testing, 1485 (19%) classified as pre-diagnostic, 1693 (22%) as sporadic, and 483 (6%) as repeated faecal occult blood testing. After adjusting for confounders, patients who had repeated faecal occult blood testing were significantly less likely to present with stage IV colorectal cancer at diagnosis (Odds ratio 0.46, 95% Confidence Interval 0.34-0.62) than those with no prior faecal occult blood testing. Conclusions Repeated faecal occult blood testing is associated with a decreased risk of advanced colorectal cancer. Our findings support the use of organized screening programmes that employ repeated faecal occult blood testing to improve colorectal cancer outcomes at population level.

  9. Preliminary evaluation of the diffraction behind the PROBA 3/ASPIICS optimized occulter

    NASA Astrophysics Data System (ADS)

    Baccani, Cristian; Landini, Federico; Romoli, Marco; Taccola, Matteo; Schweitzer, Hagen; Fineschi, Silvano; Bemporad, Alessandro; Loreggia, Davide; Capobianco, Gerardo; Pancrazzi, Maurizio; Focardi, Mauro; Noce, Vladimiro; Thizy, Cédric; Servaye, Jean-Sébastien; Renotte, Etienne

    2016-07-01

    PROBA-3 is a technological mission of the European Space Agency (ESA), devoted to the in-orbit demon- stration of formation flying (FF) techniques and technologies. ASPIICS is an externally occulted coronagraph approved by ESA as payload in the framework of the PROBA-3 mission and is currently in its C/D phase. FF offers a solution to investigate the solar corona close the solar limb using a two-component space system: the external occulter on one spacecraft and the optical instrument on the other, separated by a large distance and kept in strict alignment. ASPIICS is characterized by an inter-satellite distance of ˜144 m and an external occulter diameter of 1.42 m. The stray light due to the diffraction by the external occulter edge is always the most critical offender to a coronagraph performance: the designer work is focused on reducing the stray light and carefully evaluating the residuals. In order to match this goal, external occulters are usually characterized by an optimized shape along the optical axis. Part of the stray light evaluation process is based on the diffraction calculation with the optimized occulter and with the whole solar disk as a source. We used the field tracing software VirtualLabTM Fusion by Wyrowski Photonics [1] to simulate the diffraction. As a first approach and in order to evaluate the software, we simulated linear occulters, through as portions of the flight occulter, in order to make a direct comparison with the Phase-A measurements [2].

  10. Evaluation for Occult Fractures in Injured Children

    PubMed Central

    French, Benjamin; Song, Lihai; Feudtner, Chris

    2015-01-01

    OBJECTIVES: To examine variation across US hospitals in evaluation for occult fractures in (1) children <2 years old diagnosed with physical abuse and (2) infants <1 year old with injuries associated with a high likelihood of abuse and to identify factors associated with such variation. METHODS: We performed a retrospective study in children <2 years old with a diagnosis of physical abuse and in infants <1 year old with non-motor vehicle crash–related traumatic brain injury or femur fractures discharged from 366 hospitals in the Premier database from 2009 to 2013. We examined across-hospital variation and identified child- and hospital-level factors associated with evaluation for occult fractures. RESULTS: Evaluations for occult fractures were performed in 48% of the 2502 children with an abuse diagnosis, in 51% of the 1574 infants with traumatic brain injury, and in 53% of the 859 infants with femur fractures. Hospitals varied substantially with regard to their rates of evaluation for occult fractures in all 3 groups. Occult fracture evaluations were more likely to be performed at teaching hospitals than at nonteaching hospitals (all P < .001). The hospital-level annual volume of young, injured children was associated with the probability of occult fracture evaluation, such that hospitals treating more young, injured patients were more likely to evaluate for occult fractures (all P < .001). CONCLUSIONS: Substantial variation in evaluation for occult fractures among young children with a diagnosis of abuse or injuries associated with a high likelihood of abuse highlights opportunities for quality improvement in this vulnerable population. PMID:26169425

  11. Occult hemorrhage in children with severe ITP.

    PubMed

    Flores, Adolfo; Buchanan, George R

    2016-03-01

    Little is known about the frequency and significance of clinically unapparent or occult hemorrhage in ITP. Therefore, we prospectively explored the sites and frequency of occult bleeding in children with severe ITP at diagnosis or upon symptomatic relapse in a prospective, single-institution cohort study of patients ≤ 18 years of age and a platelet count ≤ 10,000/mm(3) . Data collected included bleeding severity assessment, urinalysis, fecal occult blood testing, and non-contrast brain MRI. Stool and urine samples were tested within 7 days of diagnosis or symptomatic relapse. Three months after diagnosis or relapse a noncontrast brain MRI evaluated hemosiderin deposits resulting from prior localized hemorrhage. Fifty-two ITP patients were enrolled with a mean platelet count of 4,000/mm(3) . A significant occurrence of occult hemorrhage was identified in the urine (27%) compared with clinically overt hematuria (0.91%, P < 0.0005). CNS microbleeding in the superficial cortex of the left frontal lobe was identified in one child with occult bleeding in the urinary tract. There was no relationship between occult hemorrhage and bleeding manifestations on physical examination. Occult hemorrhage was not a harbinger of subsequent bleeding. Our findings suggest that occult hemorrhage occurs with greater frequency than overt bleeding in children with severe ITP. CNS microbleeding is a potential risk in this patient population. Assessment of brain microbleeds and microscopic hematuria in this patient population require additional study. © 2015 Wiley Periodicals, Inc.

  12. An Occultation by Saturn's Rings on 1991 October 2-3 October 2-3 Observed with the Hubble Space Telescope

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Bosh, A. S.; Cooke, M. L.; Bless, R. C.; Nelson, M. J.; Percival, J. W.; Taylor, M. J.; Dolan, J. F.; Robinson, E. L.; Van Citters, G. W.

    1993-01-01

    An occultation of the star GSC 6323-01396 (V = 11.9) by Saturn's rings was observed with the High-Speed Photometer on the Hubble Space Telescope (HST) on 1991 October 2-3. This occultation occurred when Saturn was near a stationary point, so the apparent motion of Saturn relative to the star was dominated by the HST orbital motion (8 km/s). Data were recorded simultaneously at effective wavelengths of 3200 and 7500 A, with an integration time of 0.15 s. Fifteen segments of occultation data, totaling 6.8 h, were recorded in 13 successive orbits during the 20.0 h interval from UTC 1991 October 2, 19:35 until UTC 1991 October 3, 15:35. Occultations by 43 different features throughout the classical rings were unambiguously identified in the light curve, with a second occultation by 24 of them occurring due to spacecraft orbital parallax during this extremely slow event. Occultation times for features currently presumed circular were measured and employed in a geometrical model for the rings. This model, relating the observed occultation times to feature radii and longitudes, is presented here and is used in a least-squares fit for the pole direction and radius scale of Saturn's ring system.

  13. The Pinhole/Occulter Facility

    NASA Technical Reports Server (NTRS)

    Tandberg-Hanssen, E. A. (Editor); Hudson, H. S. (Editor); Dabbs, J. R. (Editor); Baity, W. A. (Editor)

    1983-01-01

    Scientific objectives and requirements are discussed for solar X-ray observations, coronagraph observations, studies of coronal particle acceleration, and cosmic X-ray observations. Improved sensitivity and resolution can be provided for these studies using the pinhole/occulter facility which consists of a self-deployed boom of 50 m length separating an occulter plane from a detector plane. The X-ray detectors and coronagraphic optics mounted on the detector plane are analogous to the focal plane instrumentation of an ordinary telescope except that they use the occulter only for providing a shadow pattern. The occulter plane is passive and has no electrical interface with the rest of the facility.

  14. Triton stellar occultation candidates: 1995-1999

    NASA Technical Reports Server (NTRS)

    Mcdonald, S. W.; Elliot, J. L.

    1995-01-01

    We have completed a search for candidates for stellar occultations by Triton over the years 1995-1999. CCd strip scan images provided star positions in the relevant sky area to a depth of about 17.5 R magnitude. Over this time period, we find that Triton passes within 1.0 arcsec of 75 stars. Appulses with geocentric minimum separations of less than 0.35 arcsec will result in stellar occultations, but further astrometry and photometry is necessary to refine individual predictions for identification of actual occultations. Finder charts are included to aid in further studies and prediction refinement. The two most promising potential occultations, Tr176 and Tr180, occur in 1997.

  15. Amplification and protein overexpression of cyclin D1: Predictor of occult nodal metastasis in early oral cancer.

    PubMed

    Noorlag, Rob; Boeve, Koos; Witjes, Max J H; Koole, Ronald; Peeters, Ton L M; Schuuring, Ed; Willems, Stefan M; van Es, Robert J J

    2017-02-01

    Accurate nodal staging is pivotal for treatment planning in early (stage I-II) oral cancer. Unfortunately, current imaging modalities lack sensitivity to detect occult nodal metastases. Chromosomal region 11q13, including genes CCND1, Fas-associated death domain (FADD), and CTTN, is often amplified in oral cancer with nodal metastases. However, evidence in predicting occult nodal metastases is limited. In 158 patients with early tongue and floor of mouth (FOM) squamous cell carcinomas, both CCND1 amplification and cyclin D1, FADD, and cortactin protein expression were correlated with occult nodal metastases. CCND1 amplification and cyclin D1 expression correlated with occult nodal metastases. Cyclin D1 expression was validated in an independent multicenter cohort, confirming the correlation with occult nodal metastases in early FOM cancers. Cyclin D1 is a predictive biomarker for occult nodal metastases in early FOM cancers. Prospective research on biopsy material should confirm these results before implementing its use in routine clinical practice. © 2016 Wiley Periodicals, Inc. Head Neck 39: 326-333, 2017. © 2016 Wiley Periodicals, Inc.

  16. Optical performance of the New Worlds Occulter

    NASA Astrophysics Data System (ADS)

    Arenberg, Jonathan W.; Lo, Amy S.; Glassman, Tiffany M.; Cash, Webster

    2007-04-01

    The New Worlds Observer (NWO) is a multiple spacecraft mission that is capable of detecting and characterizing extra-solar planets and planetary systems. NWO consists of an external occulter and a generic space telescope, flying in tandem. The external occulter has specific requirements on its shape and size, while the telescope needs no special modification beyond that required to do high-quality astrophysical observations. The occulter is a petal-shaped, opaque screen that creates a high-suppression shadow large enough to accommodate the telescope. This article reports on the optical performance of the novel New Worlds occulter design. It also introduces two new aspects of its optical performance which enhance the detectability of extra-solar planets. We also include a brief discussion of the buildability and the tolerances of the occulter. It is also shown that an occulter design can be found for any set of science requirements. We show that NWO is a viable mission concept for the study of extra-solar planets. To cite this article: J.W. Arenberg et al., C. R. Physique 8 (2007).

  17. Stellar occultation spikes as probes of atmospheric structure and composition. [for Jupiter

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Veverka, J.

    1976-01-01

    The characteristics of spikes observed in occultation light curves of Beta Scorpii by Jupiter are discussed in terms of the gravity-gradient model. The occultation of Beta Sco by Jupiter on May 13, 1971, is reviewed, and the gravity-gradient model is defined as an isothermal atmosphere of constant composition in which the refractivity is a function only of the radial coordinate from the center of refraction, which is assumed to lie parallel to the local gravity gradient. The derivation of the occultation light curve in terms of the atmosphere, the angular diameter of the occulted star, and the occultation geometry is outlined. It is shown that analysis of the light-curve spikes can yield the He/H2 concentration ratio in a well-mixed atmosphere, information on fine-scale atmospheric structure, high-resolution images of the occulted star, and information on ray crossing. Observational limits are placed on the magnitude of horizontal refractivity gradients, and it is concluded that the spikes are the result of local atmospheric density variations: atmospheric layers, density waves, or turbulence.

  18. Constraints on atmospheric structure and helium abundance of Saturn from Cassini/UVIS and CIRS

    NASA Astrophysics Data System (ADS)

    Koskinen, Tommi; Guerlet, Sandrine

    2017-10-01

    We combine results from stellar occultations observed by Cassini/UVIS and infrared emissions observed by Cassini/CIRS to create empirical models of atmospheric structure on Saturn corresponding to the locations probed by the UVIS stellar occultations. These models span multiple occultation locations at different latitudes from 2005 to the end of 2015. In summary, we connect the temperature-pressure profiles retrieved from the CIRS data to the temperature-pressure profiles in the thermosphere retrieved from the occultations. A corresponding altitude scale is calculated and matched to the altitude scale of the density profiles that are retrieved directly from the occultations. In addition to the temperature structure, our ability to match the altitudes in the occultation light curves depends on the mean molecular weight of the atmosphere. We use the UVIS occultations to constrain the abundance of methane near the homopause, allowing us to constrain the eddy mixing rate of the atmosphere. In addition, our preliminary results are consistent with a mixing ratio of about 11% for helium in the lower atmosphere. Our results provide an important reference for future models of Saturn’s upper atmosphere.

  19. General Information about Metastatic Squamous Neck Cancer with Occult Primary

    MedlinePlus

    ... Occult Primary Treatment (Adult) (PDQ®)–Patient Version General Information About Metastatic Squamous Neck Cancer with Occult Primary ... the PDQ Adult Treatment Editorial Board . Clinical Trial Information A clinical trial is a study to answer ...

  20. Lunar occultation of Saturn. IV - Astrometric results from observations of the satellites

    NASA Technical Reports Server (NTRS)

    Dunham, D. W.; Elliot, J. L.

    1978-01-01

    The method of determining local lunar limb slopes, and the consequent time scale needed for diameter studies, from accurate occultation timings at two nearby telescopes is described. Results for photoelectric observations made at Mauna Kea Observatory during the occultation of Saturn's satellites on March 30, 1974, are discussed. Analysis of all observations of occultations of Saturn's satellites during 1974 indicates possible errors in the ephemerides of Saturn and its satellites.

  1. OCCULT-ORSER complete conversational user-language translator

    NASA Technical Reports Server (NTRS)

    Ramapriyan, H. K.; Young, K.

    1981-01-01

    Translator program (OCCULT) assists non-computer-oriented users in setting up and submitting jobs for complex ORSER system. ORSER is collection of image processing programs for analyzing remotely sensed data. OCCULT is designed for those who would like to use ORSER but cannot justify acquiring and maintaining necessary proficiency in Remote Job Entry Language, Job Control Language, and control-card formats. OCCULT is written in FORTRAN IV and OS Assembler for interactive execution.

  2. Uranus occults SAO158687. [stellar occultation and planetary parametric observation

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Veverka, J.; Millis, R. L.

    1977-01-01

    Experience gained in obtaining atmospheric parameters, oblatenesses, and diameters of Jupiter and Mars from recent stellar occultations by these planets is used to predict what can be learned from the March 1977 occultation of the star SAO158687 by Uranus. The spectra of this star and Uranus are compared to indicate the relative instrument intensities of the two objects, the four passbands where the relative intensities are most nearly equal are listed, and expected photon fluxes from the star are computed on the assumption that it has UBVRI colors appropriate for a K5 main-sequence object. It is shown that low photon noise errors can be achieved by choosing appropriate passbands for observation, and the rms error expected for the Uranus temperature profiles obtained from the occultation light curves is calculated. It is suggested that observers of this occultation should record their data digitally for optimum time resolution.

  3. Design of an occulter testbed at flight Fresnel numbers

    NASA Astrophysics Data System (ADS)

    Sirbu, Dan; Kasdin, N. Jeremy; Kim, Yunjong; Vanderbei, Robert J.

    2015-01-01

    An external occulter is a spacecraft flown along the line-of-sight of a space telescope to suppress starlight and enable high-contrast direct imaging of exoplanets. Laboratory verification of occulter designs is necessary to validate the optical models used to design and predict occulter performance. At Princeton, we are designing and building a testbed that allows verification of scaled occulter designs whose suppressed shadow is mathematically identical to that of space occulters. Here, we present a sample design operating at a flight Fresnel number and is thus representative of a realistic space mission. We present calculations of experimental limits arising from the finite size and propagation distance available in the testbed, limitations due to manufacturing feature size, and non-ideal input beam. We demonstrate how the testbed is designed to be feature-size limited, and provide an estimation of the expected performance.

  4. Evaluation of Inversion Methods Applied to Ionospheric ro Observations

    NASA Astrophysics Data System (ADS)

    Rios Caceres, Arq. Estela Alejandra; Rios, Victor Hugo; Guyot, Elia

    The new technique of radio-occultation can be used to study the Earth's ionosphere. The retrieval processes of ionospheric profiling from radio occultation observations usually assume spherical symmetry of electron density distribution at the locality of occultation and use the Abel integral transform to invert the measured total electron content (TEC) values. This pa-per presents a set of ionospheric profiles obtained from SAC-C satellite with the Abel inversion technique. The effects of the ionosphere on the GPS signal during occultation, such as bending and scintillation, are examined. Electron density profiles are obtained using the Abel inversion technique. Ionospheric radio occultations are validated using vertical profiles of electron con-centration from inverted ionograms , obtained from ionosonde sounding in the vicinity of the occultation. Results indicate that the Abel transform works well in the mid-latitudes during the daytime, but is less accurate during the night-time.

  5. James Webb Space Telescope Observations of Stellar Occultations by Solar System Bodies and Rings

    NASA Technical Reports Server (NTRS)

    Santos-Sanz, P.; French, R. G.; Pinilla-Alonso, N.; Stansberry, J.; Lin, Z-Y.; Zhang, Z-W.; Vilenius, E.; Mueller, Th.; Ortiz, J. L.; Braga-Ribas, F.; hide

    2016-01-01

    In this paper, we investigate the opportunities provided by the James Webb Space Telescope (JWST) for significant scientific advances in the study of Solar System bodies and rings using stellar occultations. The strengths and weaknesses of the stellar occultation technique are evaluated in light of JWST's unique capabilities. We identify several possible JWST occultation events by minor bodies and rings and evaluate their potential scientific value. These predictions depend critically on accurate a priori knowledge of the orbit of JWST near the Sun–Earth Lagrange point 2 (L2). We also explore the possibility of serendipitous stellar occultations by very small minor bodies as a byproduct of other JWST observing programs. Finally, to optimize the potential scientific return of stellar occultation observations, we identify several characteristics of JWST's orbit and instrumentation that should be taken into account during JWST's development.

  6. Influence of misalignments on the performance of externally occulted solar coronagraphs. Application to PROBA-3/ASPIICS

    NASA Astrophysics Data System (ADS)

    Shestov, S. V.; Zhukov, A. N.

    2018-05-01

    Context. The ASPIICS instrument is a novel externally occulted coronagraph that will be launched on board the PROBA-3 mission of the European Space Agency. The external occulter will be placed on one satellite 150 m ahead of the second satellite that will carry an optical instrument. During 6 h out of 19.38 h of orbit, the satellites will fly in a precise (accuracy around a few millimeters) formation, constituting a giant externally occulted coronagraph. The large distance between the external occulter and the primary objective will allow observations of the white-light solar corona starting from extremely low heights 1.1R⊙. Aims: We intend to analyze influence of shifts of the satellites and misalignments of optical elements on the ASPIICS performance in terms of diffracted light. Based on the quantitative influence of misalignments on diffracted light, we provide a recipe for choosing the size of the internal occulter (IO) to achieve a trade-off between the minimal height of observations and sustainability to possible misalignments. Methods: We considered different types of misalignments and analyzed their influence from optical and computational points of view. We implemented a numerical model of the diffracted light and its propagation through the optical system and computed intensities of diffracted light throughout the instrument. Our numerical approach is based on a model from the literature that considered the axisymmetrical case. Here we extend the model to include nonsymmetrical cases and possible misalignments. Results: The numerical computations fully confirm the main properties of the diffracted light that we obtained from semi-analytical consideration. We obtain that relative influences of various misalignments are significantly different. We show that the internal occulter with RIO = 1.694 mm = 1.1R⊙ is large enough to compensate possible misalignments expected to occur in PROBA-3/ASPIICS. Besides that we show that apodizing the edge of the internal occulter leads to additional suppression of the diffracted light. Conclusions: We conclude that the most important misalignment is the tilt of the telescope with respect to the line connecting the center of the external occulter and the entrance aperture. Special care should be taken to co-align the external occulter and the coronagraph, which means co-aligning the diffraction fringe from the external occulter and the internal occulter. We suggest that the best orientation strategy is to point the coronagraph to the center of the external occulter.

  7. The Clinical Significance of Occult Gastrointestinal Primary Tumours in Metastatic Cancer: A Population Retrospective Cohort Study.

    PubMed

    Hannouf, Malek B; Winquist, Eric; Mahmud, Salaheddin M; Brackstone, Muriel; Sarma, Sisira; Rodrigues, George; Rogan, Peter K; Hoch, Jeffrey S; Zaric, Gregory S

    2018-01-01

    The purpose of this study was to estimate the incidence of occult gastrointestinal (GI) primary tumours in patients with metastatic cancer of uncertain primary origin and evaluate their influence on treatments and overall survival (OS). We used population heath data from Manitoba, Canada to identify all patients initially diagnosed with metastatic cancer between 2002 and 2011. We defined patients to have "occult" primary tumour if the primary was found at least 6 months after initial diagnosis. Otherwise, we considered primary tumours as "obvious." We used propensity-score methods to match each patient with occult GI tumour to four patients with obvious GI tumour on all known clinicopathologic features. We compared treatments and 2-year survival data between the two patient groups and assessed treatment effect on OS using Cox regression adjustment. Eighty-three patients had occult GI primary tumours, accounting for 17.6% of men and 14% of women with metastatic cancer of uncertain primary. A 1:4 matching created a matched group of 332 patients with obvious GI primary tumour. Occult cases compared to the matched group were less likely to receive surgical interventions and targeted biological therapy, and more likely to receive cytotoxic empiric chemotherapeutic agents. Having an occult GI tumour was associated with reduced OS and appeared to be a nonsignificant independent predictor of OS when adjusting for treatment differences. GI tumours are the most common occult primary tumours in men and the second most common in women. Patients with occult GI primary tumours are potentially being undertreated with available GI site-specific and targeted therapies.

  8. Evaluation for Occult Fractures in Injured Children.

    PubMed

    Wood, Joanne N; French, Benjamin; Song, Lihai; Feudtner, Chris

    2015-08-01

    To examine variation across US hospitals in evaluation for occult fractures in (1) children <2 years old diagnosed with physical abuse and (2) infants <1 year old with injuries associated with a high likelihood of abuse and to identify factors associated with such variation. We performed a retrospective study in children <2 years old with a diagnosis of physical abuse and in infants <1 year old with non-motor vehicle crash-related traumatic brain injury or femur fractures discharged from 366 hospitals in the Premier database from 2009 to 2013. We examined across-hospital variation and identified child- and hospital-level factors associated with evaluation for occult fractures. Evaluations for occult fractures were performed in 48% of the 2502 children with an abuse diagnosis, in 51% of the 1574 infants with traumatic brain injury, and in 53% of the 859 infants with femur fractures. Hospitals varied substantially with regard to their rates of evaluation for occult fractures in all 3 groups. Occult fracture evaluations were more likely to be performed at teaching hospitals than at nonteaching hospitals (all P < .001). The hospital-level annual volume of young, injured children was associated with the probability of occult fracture evaluation, such that hospitals treating more young, injured patients were more likely to evaluate for occult fractures (all P < .001). Substantial variation in evaluation for occult fractures among young children with a diagnosis of abuse or injuries associated with a high likelihood of abuse highlights opportunities for quality improvement in this vulnerable population. Copyright © 2015 by the American Academy of Pediatrics.

  9. Occult Hepatitis B Virus Infection in a Previously Vaccinated Injection Drug User.

    PubMed

    Powell, Eleanor A; Razeghi, Sanam; Zucker, Stephen; Blackard, Jason T

    2016-02-01

    Occult hepatitis B virus (HBV) is defined by the presence of HBV DNA in patient sera in the absence of HBsAg. Occult HBV has been associated with hepatocellular carcinoma, reactivation during immune suppression, and transmission to others. While the hepatitis B vaccine is very effective at preventing chronic HBV infection, recent studies indicate it is less effective at preventing occult HBV following infant vaccination. No studies, however, have examined the efficacy of adult HBV vaccination at preventing occult HBV. Here, we present the first report of occult HBV following adult vaccination. A 21-year old Caucasian female presented with tricuspid valve endocarditis secondary to methicillin-susceptible Staphylococcus aureus with non-ischemic cardiomyopathy. She reported active use of intravenous drugs. Her liver enzymes were elevated (ALT = 1873 IU/mL; AST = 4518 IU/mL), and she was found to have HCV and occult HBV. HBV viral loads ranged from 4608 - 8364 copies IU/mL during hospitalization. The patient's HBV was sequenced and found to be genotype D3 without any known diagnostic escape mutations. Immune complexes that may have prevented HBsAg detection were not observed. HBV vaccination in infancy is effective at preventing chronic HBV infection but is less effective at preventing occult HBV infection. Similar studies examining the efficacy of adult HBV vaccination in preventing occult HBV have not been performed. This case highlights the importance of carefully determining the HBV status of high-risk individuals, as vaccination history and the presence of anti-HBs may not be adequate to rule out HBV infection, even in the absence of HBsAg.

  10. Strong scintillations during atmospheric occultations Theoretical intensity spectra. [radio scattering during spacecraft occultations by planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Hinson, D. P.

    1986-01-01

    Each of the two Voyager spacecraft launched in 1977 has completed a reconnaissance of the Jovian and Saturnian systems. In connection with occultation experiments, strong scintillations were observed. Further theoretical work is required before these scintillations can be interpreted. The present study is, therefore, concerned with the derivation of a theory for strong scattering during atmospheric occultation experiments, taking into account as fundamental quantity of interest the spatial spectrum (or spectral density) of intensity fluctuations. Attention is given to a theory for intensity spectra, and numerical calculations. The new formula derived for Phi-i accounts for strong scattering of electromagnetic waves during atmospheric occultations.

  11. On the reduction of occultation light curves. [stellar occultations by planets

    NASA Technical Reports Server (NTRS)

    Wasserman, L.; Veverka, J.

    1973-01-01

    The two basic methods of reducing occultation light curves - curve fitting and inversion - are reviewed and compared. It is shown that the curve fitting methods have severe problems of nonuniqueness. In addition, in the case of occultation curves dominated by spikes, it is not clear that such solutions are meaningful. The inversion method does not suffer from these drawbacks. Methods of deriving temperature profiles from refractivity profiles are then examined. It is shown that, although the temperature profiles are sensitive to small errors in the refractivity profile, accurate temperatures can be obtained, particularly at the deeper levels of the atmosphere. The ambiguities that arise when the occultation curve straddles the turbopause are briefly discussed.

  12. Orbit dynamics and geographical coverage capabilities of satellite-based solar occultation experiments for global monitoring of stratospheric constituents

    NASA Technical Reports Server (NTRS)

    Brooks, D. R.

    1980-01-01

    Orbit dynamics of the solar occultation technique for satellite measurements of the Earth's atmosphere are described. A one-year mission is simulated and the orbit and mission design implications are discussed in detail. Geographical coverage capabilities are examined parametrically for a range of orbit conditions. The hypothetical mission is used to produce a simulated one-year data base of solar occultation measurements; each occultation event is assumed to produce a single number, or 'measurement' and some statistical properties of the data set are examined. A simple model is fitted to the data to demonstrate a procedure for examining global distributions of atmospheric constitutents with the solar occultation technique.

  13. Spherical Occulter Coronagraph Cubesat

    NASA Technical Reports Server (NTRS)

    Davila, Joseph M. (Inventor); Rabin, Douglas M. (Inventor); Reginald, Nelson (Inventor); Gong, Qian (Inventor); Shah, Neerav (Inventor); Chamberlin, Phillip C. (Inventor)

    2018-01-01

    The present invention relates to a space-based instrument which provides continuous coronal electron temperature and velocity images, for a predetermined period of time, thereby improving the understanding of coronal evolution and how the solar wind and Coronal Mass Ejection transients evolve from the low solar atmosphere through the heliosphere for an entire solar rotation. Specifically, the present invention relates to using a 6U spherical occulter coronagraph CubeSat, and a relative navigational system (RNS) that controls the position of the spacecraft relative to the occulting sphere. The present invention innovatively deploys a free-flying spherical occulter, and after deployment, the actively controlled CubeSat will provide an inertial formation flying with the spherical occulter and Sun.

  14. Probing Titan's atmosphere with a stellar occultation

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.

    1991-01-01

    The 3 July, 1989 occultation of 28 Sgr by Titan is discussed. The star was readily detectable throughout the occultation, reaching a minimum normalized flux of about 0.05. The occultation probed Titan's atmosphere in a region not studied by the Voyager spacecraft. The region is important for the aerobraking of Titan entry probes, and direct information about its properties is important for the Cassini mission. Occultation data (normalized stellar flux vs universal time) is shown in chart form for NASA supported stations, along with data from a collaborating group at the Wise observatory in Israel. Strong scintillation data of the star is noticeable in the data records, and provides information on waves/turbulence in Titan's high atmosphere.

  15. [A retrospective analysis on occult neck lymphatic metastasis in early tongue cancer].

    PubMed

    Gong, Q L; Bian, C; Liu, H

    2016-10-07

    Objective: To investigate the number and level of occult neck lymphatic metastasis for squamous cell carcinoma of tongue in clinical stage Ⅰ/Ⅱ, and the relationship between cell differentiation and occult neck lymphatic metastasis. Methods: A total of 101 cases diagnosed preoperatively as having squamous cell carcinoma of tongue in clinical stage Ⅰ/Ⅱ (cT1/T2N0M0) between January 2005 and April 2015 were analysed retrospectively. Whether presence of occult neck lymphatic metastasis in these cases was studied. Results: Occult neck lymphatic metastases were found in 22 (21.78%) of 101 cases, 10 men and 12 women, with an age range of 22 to 83 years. There was not statistically significant association between tumor size or cell differentiation and occult neck lymphatic metastasis ( P >0.05). The metastasis occurred most commonly in level Ⅱ, followed by levelsⅠ, Ⅲ and Ⅳ. There was no lymph node metastasis in Level Ⅴ. There were total 20 cases with occult neck lymphatic metastasis in at least one of levelⅠ, Ⅱ, Ⅲ(90.9%), One of these case was skipping metastasis in level Ⅲ(4.6%). Conclusion: The early tongue cancer has a high rate of occult lymph metastasis, which occurs commonly in levels Ⅱ, Ⅰ and Ⅲ, but there is not significant association between the metastasis and tumor size or cell differentiation.

  16. Preoperative predictors of occult nodal disease in cT1N0 oral cavity squamous cell carcinoma: Review of 2623 cases.

    PubMed

    Zhan, Kevin Y; Morgan, Patrick F; Neskey, David M; Kim, Joanne J; Huang, Andrew T; Garrett-Mayer, Elizabeth; Day, Terry A

    2018-05-14

    Nodal disease predicts survival in oral cavity squamous cell carcinoma (SCC). Currently, no large studies on predictors of occult nodal disease in cT1N0 oral cavity SCC exist. The National Cancer Database (NCDB) review for cT1N0 oral cavity SCC with surgical resection and elective neck dissection (END). The number of patients found with occult nodal disease was 2623 (15.1%). In multivariable regression, female sex and tumor differentiation predict occult nodal disease. Occult nodal disease incidence was 5.9% in well-differentiated tumors, 17.4% in moderately differentiated tumors, and 28.5% in poorly differentiated tumor (P < .001). Women with oral tongue tumors had higher occult nodal disease (19.1%) than men (12%; P = .001). Adjusted odds ratios (aORs) for occult nodal disease in women were: aOR 1.26; 95% confidence interval (CI) 1.01-1.59; P = .045; moderately differentiated aOR 3.52; 95% CI 2.47-5.01; P < .001; and poorly differentiated aOR 6.25; 95% CI 4.17-9.38; P < .001. Sex and tumor differentiation significantly predict occult nodal disease. END is recommended for all moderately and poorly differentiated cT1N0 oral cavity SCC, regardless of the depth of invasion. One can consider not performing END in well-differentiated tumors. © 2018 Wiley Periodicals, Inc.

  17. Intestinal blood loss as an aggravating factor of iron deficiency in infants aged 9 to 12 months fed whole cow's milk.

    PubMed

    Fernandes, Sandra Maria Rodrigues; de Morais, Mauro Batista; Amancio, Olga Maria Silverio

    2008-02-01

    To verify the occurrence of occult intestinal blood loss and iron deficiency in infants aged 9 to 12 months. A consecutive sample of 98 infants of the Pediatric Public Health Primary Care Unit in the town of Arapongas, Parana State, Brazil was involved in this cross-sectional study. Dietary history, hemoglobin, serum iron, transferrin saturation, ferritin, and an occult fecal blood loss investigation, by the immune chromatographic method specific for human hemoglobin were performed. Presence of occult intestinal blood occurred in 8/23 of the breast-fed (plus complementary feed) infants and in 30/64 of the infants who were fed with cow's milk (plus complementary feed) (P=0.449). The comparison of body iron indicators in accordance to positive or negative occult fecal blood, did not show any significant difference in the 23 breast-fed infants. Serum ferritin (median=4.2 ng/mL) was significantly lower (P=0.004) in infants who received whole cow's milk and had positive occult fecal blood, than in those infants who received whole cow's milk but were without occult fecal blood (median=12.1 ng/mL). In breast-fed infants with negative occult fecal blood, iron deficiency severity is not greater than in those with positive results. In infants fed whole cow's milk, occult fecal blood loss is an aggravating factor of iron deficiency.

  18. Toward a Next Generation Solar Coronagraph: Diffracted Light Simulation and Test Results for a Cone Occulter with Tapered Surface

    NASA Astrophysics Data System (ADS)

    Yang, Heesu; Bong, Su-Chan; Cho, Kyung-Suk; Choi, Seonghwan; Park, Jongyeob; Kim, Jihun; Baek, Ji-Hye; Nah, Jakyoung; Sun, Mingzhe; Gong, Qian

    2018-04-01

    In a solar coronagraph, the most important component is an occulter to block the direct light from the disk of the sun Because the intensity of the solar outer corona is 10-6 to 10-10 times of that of the solar disk (\\ir), it is necessary to minimize scattering at the optical elements and diffraction at the occulter. Using a Fourier optic simulation and a stray light test, we investigated the performance of a compact coronagraph that uses an external truncated-cone occulter without an internal occulter and Lyot stop. In the simulation, the diffracted light was minimized to the order of 7.6×10-10 \\ir when the cone angle θc was about 0.39°. The performance of the cone occulter was then tested by experiment. The level of the diffracted light reached the order of 6×10-9 \\ir at θc=0.40°. This is sufficient to observe the outer corona without additional optical elements such as a Lyot stop or inner occulter. We also found the manufacturing tolerance of the cone angle to be 0.05°, the lateral alignment tolerance was 45 \\um, and the angular alignment tolerance was 0.043°. Our results suggest that the physical size of coronagraphs can be shortened significantly by using a cone occulter.

  19. Measurement of stellar occultations

    NASA Astrophysics Data System (ADS)

    Eberle, Andreas

    2008-09-01

    Whenever an asteroid occults a star, we have the opportunity to study that asteroid in great detail. As frequently shown in the past, amateur astronomers1 have the necessary equipment to measure such events successfully2. Combined with the dense net of amateur observatories and online coordination tools3 for movable stations, they can create fine grids to detect even small bodies. The analysis of these events gives us the possibility to receive high precision astrometry data, to determine the asteroids size and shape (and therefore its albedo), and even to collect information on the star itself.4 While usually a set of several light curves is required to do so, a single recording5 of (10734) Wieck's occultation of HIP 22157 on 2008 Feb 08 was sufficient to retrieve the necessary data6. 1 Observation campaigns are organized by the International Occultation Timing Association (IOTA), http://www.iota-es.de/ 2 for results see e.g. euraster.net by E. Frappa, http://www.euraster.net/ 3 Occult Watcher by H. Pavlov, http://www.hristopavlov.net/OccultWatcher/OccultWatcher.html 4 see K. Miyashita's analysis of the observation of the occultation of TYC 1886-01206-1 by Kalliope and Linus, http://www005.upp.so-net.ne.jp/k miyash/occ02/kalliope/doublestar en.html 5 recording obtained by H. Michels, MPC Station Code 240 6 using Limovie by K. Miyashita

  20. A 3-D shape model of Interamnia

    NASA Astrophysics Data System (ADS)

    Sato, Isao

    2015-08-01

    A 3-D shape model of the sixth largest of the main belt asteroids, (704) Interamnia, is presented. The model is reproduced from its two stellar occultation observations and six lightcurves between 1969 and 2011. The first stellar occultation was the occultation of TYC 234500183 on 1996 December 17 observed from 13 sites in the USA. An elliptical cross section of (344.6±9.6km)×(306.2±9.1km), for position angle P=73.4±12.5 was fitted. The lightcurve around the occultation shows that the peak-to-peak amplitude was 0.04 mag. and the occultation phase was just before the minimum. The second stellar occultation was the occultation of HIP 036189 on 2003 March 23 observed from 39 sites in Japan and Hawaii. An elliptical cross section of (349.8±0.9km)×(303.7±1.7km), for position angle P=86.0±1.1 was fitted. A companion of 8.5 mag. of the occulted star was discovered whose separation is 12±2 mas (milli-arcseconds), P=148±11 . A combined analysis of rotational lightcurves and occultation chords can return more information than can be obtained with either technique alone. From follow-up photometric observations of the asteroid between 2003 and 2011, its rotation period is determined to be 8.728967167±0.00000007 hours, which is accurate enough to fix the rotation phases at other occultation events. The derived north pole is λ2000=259±8, β2000=-50±5 (retrograde rotation); the lengths of the three principal axes are 2a=361.8±2.8km, 2b=324.4±5.0km, 2c=297.3±3.5km, and the mean diameter is D=326.8±3.0km. Supposing the mass of Interamnia as (3.5±0.9)×10-11 solar masses, the density is then ρ=3.8±1.0 g cm-3.

  1. [Stellar Occultation Studies of Small Bodies in the Outer Solar System: Accomplishments, Status, and Plans

    NASA Technical Reports Server (NTRS)

    Elliott, James

    2005-01-01

    Bodies residing in the outer solar system exhibit unique physical processes, and some of the lessons learned from them can be applied to understanding what occurred in the outer solar system during its formation and early evolution. Pluto, the largest known Kuiper Belt object (KBO), and its near twin Triton--an ex-KBO that has been captured by Neptune--have nitrogen atmospheres that are in vapor-pressure equilibrium with surface ice. These atmospheres are most sensitively probed from Earth by the technique of Stellar occultations, which can provide the temperature and pressure profiles of these atmospheres at a spatial resolution of a few kilometers. Recent results from occultations show that the surface pressure of Triton's atmosphere has been increasing and that the shape of the atmosphere deviates from its expected spherical figure. With the occultation technique we can also learn the sizes of smaller bodies that have formed in the outer solar system: Charon, the Centaurs, and KBOs. Our proposed program involves identifying occultation candidates, predicting occultations, observing occultations, analysis of the data, and synthesis of the occultation results with other data. The main goals for our proposed work are to (i) further observe occultations by Triton with the objectives of understanding its pressure changes, distortion, and enigmatic thermal structure (ii) determine whether the abrupt drop in Pluto's stellar occultation light curve is caused by a sharp thermal gradient near its surface or by atmospheric haze, (iii) further observations to characterize the potential collapse of Pluto's atmosphere as it recedes from the sun (information that should be of interest to the Pluto-Kuiper Express), ( iv ) determine Charon's radius more accurately than can be done with the mutual events to derive a better estimate of Charon's density, and ( v ) directly determine the size (and albedo) of Centaurs with the goal of more accurately estimating the sizes of KBOS.

  2. Detection of occult endocervical glandular dysplasia in cervical conization specimens for squamous lesions.

    PubMed

    Sopracordevole, F; Clemente, N; Alessandrini, L; Di Giuseppe, J; Cigolot, F; Buttignol, M; Ciavattini, A; Canzonieri, V

    2017-03-01

    The aim of this work was to evaluate the incidence of occult cervical glandular intraepithelial neoplasia (CGIN) and adenocarcinoma of the cervix (AC) in women treated with CO2-laser conization for cervical intraepithelial neoplasia (CIN) or squamocellular cervical cancer (SCC). The medical records of all women with a histological diagnosis of squamous lesions of the uterine cervix (persistent CIN1, CIN2, CIN3 and SCC) who were subsequently treated with CO2-laser conization at our institution, during the period from January 1991 to December 2014, were analyzed in a retrospective case series. Among the 1004 women fulfilling the study inclusion/exclusion criteria, 77 cases (7.7%) of occult glandular lesions (CGIN and AC) were detected on the final cone specimen (48 cases of occult low-grade cervical glandular intraepithelial neoplasia (LCGIN), 25 cases of occult high-grade cervical glandular intraepithelial neoplasia (HCGIN), and four cases of occult "usual-type" AC). No difference in the mean age between women diagnosed with occult glandular lesions and women without occult glandular lesions on the final specimen emerged (39.1±9.3 vs 38.4±9.4, p=0.5). In women with occult LCGIN on cone specimen, mean follow-up of 48 months was reported (range 7-206 months) and no cases of progression to HCGIN or AC were observed. In conclusion, a relatively high rate of occult glandular lesions was found in women treated for squamous lesions. The natural history of CGIN is still uncertain and, in particular, there are some controversies as to whether LCGIN is a precursor lesion of HCGIN or AC. In this context the role of pathologists become very important since the appropriate diagnosis of these lesions could have potential implications in the clinical management of these patients. Copyright © 2017 Elsevier GmbH. All rights reserved.

  3. Evaluation and Improved Use of Fecal Occult Blood Test in the Constipated Child.

    PubMed

    Kilway, Denise M

    2016-01-01

    This quality improvement project examined the use of fecal occult blood test in the constipated child in a pediatric gastroenterology outpatient clinic. A retrospective chart review was completed on 100 children seen for an initial visit with the gastroenterology provider. The number of fecal occult blood tests performed and the child's coinciding symptoms were tallied and compared with the North American Society of Pediatric Gastroenterology, Hepatology, and Nutrition recommendations. An educational intervention was held with the pediatric gastroenterology providers consisting of a PowerPoint presentation summarizing aims of the quality improvement project and reviewing recommendations for use of fecal occult blood test in the constipated child. Pre- and post-intervention chart review data sets were compared. Results showed a 19.6% decrease in the use of fecal occult blood tests performed during the post-intervention timeframe. However, when used in conjunction with North American Society of Pediatric Gastroenterology, Hepatology, and Nutrition recommendations, the appropriateness of fecal occult blood test use increased by 71.4% in the post-intervention patients. Reviewing the recommendations with gastroenterology providers assisted in optimizing the meaningful use of fecal occult blood test, improving quality and safety of care for children seen in the pediatric gastroenterology outpatient clinic.

  4. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter.

    PubMed

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Lee, Ho Min; Back, In Hwa; Eom, Kyeong Soo

    2016-06-01

    Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment.

  5. Occult Intertrochanteric Fracture Mimicking the Fracture of Greater Trochanter

    PubMed Central

    Chung, Phil Hyun; Kang, Suk; Kim, Jong Pil; Kim, Young Sung; Back, In Hwa; Eom, Kyeong Soo

    2016-01-01

    Purpose Occult intertrochanteric fractures are misdiagnosed as isolated greater trochanteric fractures in some cases. We investigated the utility of three-dimensional computed tomography (3D-CT) and magnetic resonance imaging (MRI) in the diagnosis and outcome management of occult intertrochanteric fractures. Materials and Methods This study involved 23 cases of greater trochanteric fractures as diagnosed using plain radiographs from January 2004 to July 2013. Until January 2008, 9 cases were examined with 3D-CT only, while 14 cases were screened with both 3D-CT and MRI scans. We analyzed diagnostic accuracy and treatment results following 3D-CT and MRI scanning. Results Nine cases that underwent 3D-CT only were diagnosed with isolated greater trochanteric fractures without occult intertrochanteric fractures. Of these, a patient with displacement received surgical treatment. Of the 14 patients screened using both CT and MRI, 13 were diagnosed with occult intertrochanteric fractures. Of these, 11 were treated with surgical intervention and 2 with conservative management. Conclusion Three-dimensional CT has very low diagnostic accuracy in diagnosing occult intertrochanteric fractures. For this reason, MRI is recommended to confirm a suspected occult intertrochanteric fracture and to determine the most appropriate mode of treatment. PMID:27536653

  6. Scaled model guidelines for solar coronagraphs' external occulters with an optimized shape.

    PubMed

    Landini, Federico; Baccani, Cristian; Schweitzer, Hagen; Asoubar, Daniel; Romoli, Marco; Taccola, Matteo; Focardi, Mauro; Pancrazzi, Maurizio; Fineschi, Silvano

    2017-12-01

    One of the major challenges faced by externally occulted solar coronagraphs is the suppression of the light diffracted by the occulter edge. It is a contribution to the stray light that overwhelms the coronal signal on the focal plane and must be reduced by modifying the geometrical shape of the occulter. There is a rich literature, mostly experimental, on the appropriate choice of the most suitable shape. The problem arises when huge coronagraphs, such as those in formation flight, shall be tested in a laboratory. A recent contribution [Opt. Lett.41, 757 (2016)OPLEDP0146-959210.1364/OL.41.000757] provides the guidelines for scaling the geometry and replicate in the laboratory the flight diffraction pattern as produced by the whole solar disk and a flight occulter but leaves the conclusion on the occulter scale law somehow unjustified. This paper provides the numerical support for validating that conclusion and presents the first-ever simulation of the diffraction behind an occulter with an optimized shape along the optical axis with the solar disk as a source. This paper, together with Opt. Lett.41, 757 (2016)OPLEDP0146-959210.1364/OL.41.000757, aims at constituting a complete guide for scaling the coronagraphs' geometry.

  7. The Treatment of the Occult in General Encyclopedias.

    ERIC Educational Resources Information Center

    Sonnenfeld, Gary F.

    This paper is a content analysis of three general encyclopedias, "Encyclopedia Americana" (EA), "Encyclopaedia Brittanica" (EB), and "World Book Encyclopedia" (WBC), which quantifies the treatment of the occult. Entries are selected from each by starting with the article "Occultism" and tracing all…

  8. Developing an Optical Lunar Occultation Measurement Reduction System for Observations at Kaau Observatory

    NASA Astrophysics Data System (ADS)

    Malawi, Abdulrahman A.

    2013-06-01

    We present here a detailed explanation of the reduction method that we use to determine the angular diameters of the stars occulted by the dark limb of the moon. This is a main part of the lunar occultation observation program running at King Abdul Aziz University observatory since late 1993. The process is based on the least square model fitting method of analyzing occultation data, first introduced by Nather et al. (Astron. J. 75:963, 1970).

  9. Analysis of a Triple Star System Occulted By Saturn’s Rings

    NASA Astrophysics Data System (ADS)

    Bratcher, Allison; Colwell, J. E.; Bolin, B.

    2012-10-01

    On January 4, 2012, the Ultraviolet Imaging Spectrograph aboard the Cassini Spacecraft observed Saturn’s rings as they occulted the triple star system, Iota Orionis. Remarkably, the brightest star was occulted by the moon Prometheus, and we provide the timing information of first and last contact for navigation purposes and a chord across the moon. The large separation of the individual stars projected in the ring plane makes it possible to measure the profiles of narrow features in the rings as they were occulted by each of the three stars. This occultation thus provides a unique opportunity to measure short-scale longitudinal variations in narrow ringlets with stellar occultation data that usually provide only a single longitudinal sample. Iota Orionis has a low elevation angle (B=1.4 degrees) above the plane of the rings, enhancing the sensitivity of the occultation (by a factor of 1/sin(B)=41) to the optically thin regions of the rings such as the C Ring and the Cassini Division as well as faint ringlets in the Encke gap. We distinguished the three signals by creating a model triple star signal using data from another occultation. We were able to identify several faint, narrow ringlets, including two in the Encke gap, occulted by two of the three stars and more prominent ringlets, such as the Huygens ringlet, in all three stellar light curves. We present the equivalent widths of these ringlets in the data from this triple star system and limits on ring variability over the azimuthal separation of the stars that ranges from 6000 km at the inner C ring to 200 km at the outer A ring.

  10. Characterization of the occult nature of frequently occurring pediatric motor vehicle crash injuries.

    PubMed

    Doud, Andrea N; Schoell, Samantha L; Talton, Jennifer W; Barnard, Ryan T; Petty, John K; Stitzel, Joel D; Weaver, Ashley A

    2018-04-01

    Occult injuries are those likely to be missed on initial assessment by first responders and, though initially asymptomatic, they may present suddenly and lead to rapid patient decompensation. No scoring systems to quantify the occultness of pediatric injuries have been established. Such a scoring system will be useful in the creation of an Advanced Automotive Crash Notification (AACN) system that assists first responders in making triage decisions following a motor vehicle crash (MVC). The most frequent MVC injuries were determined for 0-4, 5-9, 10-14 and 15-18 year olds. For each age-specific injury, experts with pediatric trauma expertise were asked to rate the likelihood that the injury may be missed by first responders. An occult score (ranging from 0-1) was calculated by averaging and normalizing the responses of the experts polled. Evaluation of all injuries across all age groups demonstrated greater occult scores for the younger age groups compared to older age groups (mean occult score 0-4yo: 0.61 ± 0.23, 5-9yo: 0.53 ± 0.25, 10-14yo: 0.48 ± 0.23, and 15-18yo: 0.42 ± 0.22, p < 0.01). Body-region specific occult scores revealed that experts judged abdominal, spine and thoracic injuries to be more occult than injuries to other body regions. The occult scores suggested that injuries are more difficult to detect in younger age groups, likely given their inability to express symptoms. An AACN algorithm that can predict the presence of clinically undetectable injuries at the scene can improve triage of children with these injuries to higher levels of care. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Prediction of occult hepatitis B virus infection in liver transplant donors through hepatitis B virus blood markers.

    PubMed

    Tandoi, Francesco; Caviglia, Gian Paolo; Pittaluga, Fabrizia; Abate, Maria Lorena; Smedile, Antonina; Romagnoli, Renato; Salizzoni, Mauro

    2014-11-01

    Occult hepatitis B virus infection is defined as detectable HBV-DNA in liver of HBsAg-negative individuals, with or without detectable serum HBV-DNA. In deceased liver donors, results of tissue analysis cannot be obtained prior to allocation for liver transplantation. we investigated prevalence and predictability of occult hepatitis B using blood markers of viral exposure/infection in deceased liver donors. In 50 consecutive HBsAg-negative/anti-HBc-positive and 20 age-matched HBsAg-negative/anti-HBc-negative donors, a nested-PCR assay was employed in liver biopsies for diagnosis of occult hepatitis B according to Taormina criteria. All donors were characterized for plasma HBV-DNA and serum anti-HBs/anti-HBe. In liver tissue, occult hepatitis B was present in 30/50 anti-HBc-positive (60%) and in 0/20 anti-HBc-negative donors (p<0.0001). All anti-HBc-positive donors with detectable HBV-DNA in plasma (n=5) or anti-HBs>1,000 mIU/mL (n=5) eventually showed occult infection, i.e, 10/30 occult hepatitis B-positive donors which could have been identified prior to transplantation. In the remaining 40 anti-HBc-positive donors, probability of occult infection was 62% for anti-HBe-positive and/or anti-HBs ≥ 58 mIU/mL; 29% for anti-HBe-negative and anti-HBs<58 mIU/mL. In deceased donors, combining anti-HBc with other blood markers of hepatitis B exposure/infection allows to predict occult hepatitis B with certainty and speed in one third of cases. These findings might help refine the allocation of livers from anti-HBc-positive donors. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  12. Plasma D-dimer levels and ischaemic lesions in multiple vascular regions can predict occult cancer in patients with cryptogenic stroke.

    PubMed

    Gon, Y; Sakaguchi, M; Takasugi, J; Kawano, T; Kanki, H; Watanabe, A; Oyama, N; Terasaki, Y; Sasaki, T; Mochizuki, H

    2017-03-01

    Cancer patients with cryptogenic stroke often have high plasma D-dimer levels and lesions in multiple vascular regions. Hence, if patients with cryptogenic stroke display such characteristics, occult cancer could be predicted. This study aimed to investigate the clinical characteristics of cryptogenic stroke as the first manifestation of occult cancer and to determine whether plasma D-dimer levels and lesions in multiple vascular regions can predict occult cancer in patients with cryptogenic stroke. Between January 2006 and October 2015, data on 1225 patients with acute ischaemic stroke were extracted from the stroke database of Osaka University Hospital. Among them, 184 patients were classified as having cryptogenic stroke, and 120 patients without a diagnosis of cancer at stroke onset were identified. Clinical variables were analyzed between cryptogenic stroke patients with and without occult cancer. Among 120 cryptogenic stroke patients without a diagnosis of cancer, 12 patients had occult cancer. The body mass index, hemoglobin levels and albumin levels were lower; plasma D-dimer and high-sensitivity C-reactive protein levels were higher; and lesions in multiple vascular regions were more common in patients with than in those without occult cancer. Multiple logistic regression analysis revealed that plasma D-dimer levels (odds ratio, 3.48; 95% confidence interval, 1.68-8.33; P = 0.002) and lesions in multiple vascular regions (odds ratio, 7.40; 95% confidence interval, 1.70-39.45; P = 0.01) independently predicted occult cancer. High plasma D-dimer levels and lesions in multiple vascular regions can be used to predict occult cancer in patients with cryptogenic stroke. © 2016 EAN.

  13. Altered regional and circuit resting-state activity in patients with occult spastic diplegic cerebral palsy.

    PubMed

    Mu, Xuetao; Wang, Zhiqun; Nie, Binbin; Duan, Shaofeng; Ma, Qiaozhi; Dai, Guanghui; Wu, Chunnan; Dong, Yuru; Shan, Baoci; Ma, Lin

    2017-10-07

    Very few studies have been made to investigate functional activity changes in occult spastic diplegic cerebral palsy (SDCP). The purpose of this study was to analyze whole-brain resting state regional brain activity and functional connectivity (FC) changes in patients with SDCP. We examined 12 occult SDCP and 14 healthy control subjects using resting-state functional magnetic resonance imaging. The data were analyzed using Resting-State fMRI Data Analysis Toolkit (REST) software. The regional homogeneity (ReHo), amplitude of low-frequency fluctuations (ALFF), and whole brain FC of the motor cortex and thalamus were analyzed and compared between the occult SDCP and control groups. Compared with the control group, the occult SDCP group showed decreased ReHo regions, including the bilateral frontal, parietal, and temporal lobes, the cerebellum, right cingulate gyrus, and right lenticular nucleus, whereas an increased ReHo value was observed in the left precuneus, calcarine, fusiform gyrus, and right precuneus. Compared with the control group, no significant differences in ALFF were noted in the occult SDCP group. With the motor cortex as the region of interest, the occult SDCP group showed decreased connectivity regions in the bilateral fusiform and lingual gyrus, but increased connectivity regions in the contralateral precentral and postcentral gyrus, supplementary motor area, and the ipsilateral postcentral gyrus. With the thalamus being regarded as the region of interest, the occult SDCP group showed decreased connectivity regions in the bilateral basal ganglia, cingulate, and prefrontal cortex, but increased connectivity regions in the bilateral precentral gyrus, the contralateral cerebellum, and inferior temporal gyrus. Resting-state regional brain activities and FC changes in the patients with occult SDCP exhibited a special distribution pattern, which is consistent with the pathology of the disease. Copyright © 2017. Published by Elsevier B.V.

  14. Occult Nodal Disease Prevalence and Distribution in Recurrent Laryngeal Cancer Requiring Salvage Laryngectomy.

    PubMed

    Birkeland, Andrew C; Rosko, Andrew J; Issa, Mohamad R; Shuman, Andrew G; Prince, Mark E; Wolf, Gregory T; Bradford, Carol R; McHugh, Jonathan B; Brenner, J Chad; Spector, Matthew E

    2016-03-01

    The indications for neck dissection concurrent with salvage laryngectomy in the clinically N0 setting remain unclear. Our goals were to determine the prevalence of occult nodal disease, analyze nodal disease distribution patterns, and identify predictors of occult nodal disease in a salvage laryngectomy cohort. Case series with planned data collection. Tertiary academic center. Patients with persistent or recurrent laryngeal squamous cell carcinoma (LSCC) after radiation/chemoradiation failure undergoing salvage laryngectomy with neck dissection. We analyzed a single-institution retrospective case series of patients between 1997 and 2014 and identified those who had clinically N0 (cN0) necks (n = 203). Clinical and pathologic data, including nodal prevalence and distribution, were collected and statistical analyses performed. Overall, cN0 necks had histologically positive occult nodes in 17% (n = 35) of cases. Univariate predictors of occult nodal positivity included recurrent T4 stage (34% T4 vs 12% non-T4; P = .0003) and supraglottic subsite (28% supraglottic vs 10% nonsupraglottic; P = .0006). Histologically positive nodes associated with supraglottic primaries were most frequently positive in ipsilateral levels II and III (17% and 16%). Positive nodes for glottic LSCC were most frequently positive in the ipsilateral and contralateral paratracheal nodes (11% and 9%). Histologically positive occult nodes are identified in 17% of cN0 patients undergoing salvage laryngectomy with neck dissection. Occult nodal disease varies in frequency and distribution based on tumor subsite. Predictors of high (>20%) occult nodal positivity include T4 tumors and supraglottic subsite. In glottic LSCC, the most frequent sites of occult nodal disease are the paratracheal nodal basins. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  15. Seroprevalence of occult hepatitis B among Egyptian paediatric hepatitis C cancer patients.

    PubMed

    Raouf, H E; Yassin, A S; Megahed, S A; Ashour, M S; Mansour, T M

    2015-02-01

    Occult hepatitis B infection is characterized by the presence of hepatitis B virus (HBV) DNA in the serum in the absence of hepatitis B surface antigen (HBsAg). Prevalence of hepatitis C virus (HCV) infections in Egypt is among the highest in the world. In this study, we aim at analysing the rates of occult HBV infections among HCV paediatric cancer patients in Egypt. The prevalence of occult HBV was assessed in two groups of paediatric cancer patients (HCV positive and HCV negative), in addition to a third group of paediatric noncancer patients, which was used as a general control. All groups were negative for HBsAg and positive for HCV antibody. HBV DNA was detected by nested PCR and real-time PCR. HCV was detected by real-time PCR. Sequencing was carried out in order to determine HBV genotypes to all HBV patients as well as to detect any mutation that might be responsible for the occult phenotype. Occult hepatitis B infection was observed in neither the non-HCV paediatric cancer patients nor the paediatric noncancer patients but was found in 31% of the HCV-positive paediatric cancer patients. All the detected HBV patients belonged to HBV genotype D, and mutations were found in the surface genome of HBV leading to occult HBV. Occult HBV infection seems to be relatively frequent in HCV-positive paediatric cancer patients, indicating that HBsAg negativity is not sufficient to completely exclude HBV infection. These findings emphasize the importance of considering occult HBV infection in HCV-positive paediatric cancer patients especially in endemic areas as Egypt. © 2014 John Wiley & Sons Ltd.

  16. Occult Metastases in Pelvic Lymphadenectomy Specimens From Patients With Urothelial Carcinoma of the Bladder.

    PubMed

    Gordetsky, Jennifer; Gibson, Briana; Stevens, Todd M; Ellenburg, J Luke; Grizzle, William; Rais-Bahrami, Soroush

    2016-08-01

    To identify occult metastases within lymph nodes (LNs) reported as negative by routine histologic evaluation. In patients with high-grade, muscle-invasive urothelial carcinoma (UC) of the bladder, pelvic lymphadenectomy during radical cystectomy demonstrates a survival advantage, increasing with the number of LNs removed, even if negative for metastatic disease. This finding may potentially be explained by the presence of occult metastases. Radical cystectomy specimens with high-grade UC invading the perivesical tissue and negative LNs (pT3N0) between 2000 and 2014 were reviewed. Five levels were cut for each LN block. Two sections were cut per level: 1 stained for hematoxylin and eosin and 1 for AE1/AE3. Micrometastases were defined as tumor deposits >0.2 mm but <2 mm. Isolated tumor cells were defined as ≤0.2 mm. Medical records and survival data were reviewed. We identified 21 cases, consisting of 370 lymph nodes. Six of 21 patients (29%) had occult metastases, including 5 occult metastatic UC and 1 occult metastatic prostate adenocarcinoma. There were 10 positive LNs; 2 macrometastases, 2 micrometastases, and 6 with ITCs. Two of 6 patients (33%) had lymphovascular invasion identified in the primary tumor. Kaplan-Meier analysis showed no significant difference in overall survival between the group of patients who remained N0 versus those upstaged due to discovery of occult metastases (P-value = .42). In patients with pT3 UC undergoing cystectomy, we demonstrated the presence of occult metastases in 29% of patients. The high percentage of occult metastases present in these cases possibly explains the proven survival advantage of removing "negative" LNs. This finding might also have implications in the histologic evaluation of LNs. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Prevalence of occult HBV among hemodialysis patients in two districts in the northern part of the West Bank, Palestine.

    PubMed

    Dumaidi, Kamal; Al-Jawabreh, Amer

    2014-10-01

    Occult hepatitis B infection is the case with undetectable HBsAg, but positive for HBV DNA in liver tissue and/or serum. Occult hepatitis B infection among hemodialysis patients in Palestine has been understudied. In this study, 148 hemodialysis patients from 2 northern districts in Palestine, Jenin (89) and Tulkarem (59), were investigated for occult hepatitis B, HBV, HCV infections with related risk factors. ELISA and PCR were used for the detection of anti-HBc and viral DNA, respectively. The overall prevalence of occult hepatitis B infection among the study group was 12.5% (16/128). Occult hepatitis B infection is more prevalent among males with most cases (15/16) from Jenin District. About one-third (42/132) of the hemodialysis patients were anti-HBc positive. Approximately 27% of the hemodialysis patients were infected with HCV. Around 20% (28/140) were positive for HBV DNA, but only 8.2% (12/146) of the hemodialysis patients were positive for HBsAg. The comparison between hemodialysis patients with occult hepatitis B infection and those without occult hepatitis B infection for selected risk factors and parameters as liver Enzyme, age, sex, HCV infection, blood transfusion, kidney transplant, anti-HBc, and vaccination showed no statistical significance between both categories. Duration of hemodialysis significantly affected the rate of HCV infection. HCV is significantly higher in hemodialysis patients with both Diabetes mellitus and hypertension. The prevalence of occult hepatitis B infection among hemodialysis patients is high; requiring stringent control policies. HBsAg assay is insufficient test for accurate diagnosis of HBV infection among hemodialysis patients. © 2014 Wiley Periodicals, Inc.

  18. The BRAFT1799A mutation is not associated with occult contralateral carcinoma in patients with unilateral papillary thyroid microcarcinoma.

    PubMed

    Wan, Han-Feng; Zhang, Bin; Yan, Dan-Gui; Xu, Zhen-Gang

    2015-01-01

    The phenomenon of occult carcinoma maybe observed in patients with clinically unilateral papillary thyroid microcarcinoma (PTMC). Although many studies have reported that the BRAFT1799A mutation is associated with aggressive PTMC, the relationship between BRAFT1799A mutation and occult carcinoma is unclear. The aim of this study was to investigate the risk factors, including BRAFT1799A mutation, for occult contralateral carcinoma in clinically unilateral PTMC accompanied by benign nodules in the contralateral lobe. From January 2011 to December 2013,we prospectively enrolled 89 consecutive PTMC patients with clinically unilateral carcinoma accompanied by benign nodules in the contralateral lobe who received a total thyroidectomy and cervical lymph node dissection. BRAFT1799A mutation was tested by pyrosequencing on postoperative paraffin specimens. The frequency and predictive factors for occult contralateral carcinoma were analyzed with respect to the following variables: age, gender, family history, tumor size, presence of Hashimoto thyroiditis, extrathyroidal extension, central lymph node metastasis, multifocality of primary tumor, or BRAFT1799A mutation. A total of 36 patients (40.4%) had occult PTMC in the contralateral lobe. The median diameter of the occult tumors was 0.33±0.21 cm. The BRAFT1799A mutation was found in 38 cases (42.7%). According to the univariate analysis, there were no significant differences between the presence of occult contralateral carcinoma and age, gender, family history, tumor size, presence of Hashimoto thyroiditis, extrathyroidal extension, central lymph node metastasis, multifocality of primary tumor, or BRAFT1799A mutation. Using current methods, it is difficult to preoperatively identify patients with PTMC, and further research is needed to determine predictive factors for the presence of occult contralateral carcinoma in patients with unilateral PTMC.

  19. Preliminary Global Topographic Model of Mars Based on MOLA Altimetry, Earth-Based Radar, and Viking, Mariner and MGS Occultations

    NASA Technical Reports Server (NTRS)

    Smith, David E.; Zuber, Maria T.; Neumann, Gregory A.

    1999-01-01

    The recent altimetry data acquired by MOLA over the northern hemisphere of Mars have been combined with the Earth-based radar data obtained between 1971 and 1982, and occultation measurements of the Viking 1 and 2 Orbiters, Mariner 9, and MGS to derive a global model of the shape and topography of Mars. This preliminary model has a horizontal resolution of about 300 km. Vertical accuracy is on average a few hundred meters in the region of the data. Datasets: The altimetry and radar datasets were individually binned in 1.25 degree grids and merged with the occultation data. The Viking and Mariner occultation data in the northern hemisphere were excluded from the combined dataset where MOLA altimetry were available. The laser altimetry provided extensive and almost complete coverage of the northern hemisphere north of latitude 30 while the radar provided longitudinal coverage at several latitude bands between 23N and 23S. South of this region the only data were occultations. The majority of the occultations were obtained from Mariner 9, and the rest from Viking 1 & 2, and MGS. Earlier studies had shown that the Viking and Mariner occultations were on average only accurate to 500 meters. The recent MGS occultations are accurate to a few tens of meters. However, the highest southern latitude reached by the MGS occultations is only about 64S and data near the target region for the Mars 98 lander is limited to a few Viking and Mariner observations of relatively poor quality. In addition to the above datasets the locations of the Viking 1, Viking 2, and Pathfinder landers, obtained from the radio tracking of their signals, were included.

  20. An occultation satellite system for determining pressure levels in the atmosphere

    NASA Technical Reports Server (NTRS)

    Ungar, S. G.; Lusignan, B. B.

    1972-01-01

    An operational two-satellite microwave occultation system will establish a pressure reference level to be used in fixing the temperature-pressure profile generated by the SIRS infrared sensor as a function of altitude. In the final error analysis, simulated data for the SIRS sensor were used to test the performance of the occultation system. The results of this analysis indicate that the occultation system is capable of measuring the altitude of the 300-mb level to within 24 mrms, given a maximum error of 2 K in the input temperature profile. The effects of water vapor can be corrected by suitable climatological profiles, and improvements in the accuracy of the SIRS instrument should yield additional improvements in the performance of the occultation system.

  1. Parapsychology on the couch: the psychology of occult belief in Germany, c. 1870-1939.

    PubMed

    Wolffram, Heather

    2006-01-01

    This article considers the attempts of academic psychologists and critical occultists in Germany during the late nineteenth and early twentieth centuries to construct a psychology of occult belief. While they claimed that the purpose of this new subdiscipline was to help evaluate the work of occult researchers, the emergence of a psychology of occult belief in Germany served primarily to pathologize parapsychology and its practitioners. Not to be outdone, however, parapsychologists argued that their adversaries suffered from a morbid inability to accept the reality of the paranormal. Unable to resolve through experimental means the dispute over who should be allowed to mold the public's understanding of the occult, both sides resorted to defaming their opponent. (c) 2006 Wiley Periodicals, Inc.

  2. The diameter of Juno from its occultation of AG + 0 deg 1022

    NASA Technical Reports Server (NTRS)

    Millis, R. L.; Wasserman, L. H.; Bowell, E.; Franz, O. G.; White, N. M.; Lockwood, G. W.; Nye, R.; Bertram, R.; Klemola, A.; Dunham, E.; hide

    1981-01-01

    The occultation on Dec. 11, 1979, of AG + 0 deg 1022 by Juno was observed photoelectrically from 15 sites distributed across the occultation track. The observations are well represented by a mean elliptical limb profile having semimajor and semiminor axes of 145.2 + or 0.8 and 122.8 + or - 1.9 km, respectively. The corresponding effective diameter of Juno is 267 + or - 5 km, where the uncertainty has been conservatively increased to reflect the presence of limb irregularities clearly seen in the observations. Published radiometric and polarimetric diameters for Juno are 6% to 7% smaller than the occultation result. No secondary occultations attributable to possible satellites of Juno were recorded at any of 23 photoelectrically equipped observing sites.

  3. Nondimensional Representations for Occulter Design and Performance Evaluation

    NASA Technical Reports Server (NTRS)

    Cady, Eric

    2011-01-01

    An occulter is a spacecraft with a precisely-shaped optical edges which ies in formation with a telescope, blocking light from a star while leaving light from nearby planets una ected. Using linear optimization, occulters can be designed for use with telescopes over a wide range of telescope aperture sizes, science bands, and starlight suppression levels. It can be shown that this optimization depends primarily on a small number of independent nondimensional parameters, which correspond to Fresnel numbers and physical scales and enter the optimization only as constraints. We show how these can be used to span the parameter space of possible optimized occulters; this data set can then be mined to determine occulter sizes for various mission scenarios and sets of engineering constraints.

  4. Sizes, Shapes, and Satellites of Asteroids from Occultations

    NASA Astrophysics Data System (ADS)

    Dunham, David W.; Herald, David; Preston, Steve; Timerson, Brad; Maley, Paul; Frappa, Eric; Hayamizu, Tsutomu; Talbot, John; Poro, Atila

    2016-01-01

    For 40 years, the sizes and shapes of many dozens of asteroids have been determined from observations of asteroidal occultations, and over a thousand high-precision positions of the asteroids relative to stars have been measured. Some of the first evidence for satellites of asteroids was obtained from the early efforts; now, the orbits and sizes of some satellites discovered by other means have been refined from occultation observations. Also, several close binary stars have been discovered, and the angular diameters of some stars have been measured from analysis of these observations. The International Occultation Timing Association (IOTA) coordinates this activity worldwide, from predicting and publicizing the events, to accurately timing the occultations from as many stations as possible, and publishing and archiving the observations.

  5. Dynamics and structure of planetary rings

    NASA Technical Reports Server (NTRS)

    French, R. G.

    1991-01-01

    Recent research efforts were directed towards sharpening the understanding of kinematical and dynamical properties of the Uranian rings, with the combination of Earth-based and Voyager observations, and in obtaining and interpreting new observations of the Saturn system from the remarkable stellar occultation of 3 Jul. 1989. Some of the highlights studied include: (1) a detailed comparison of structure and dynamics of the Uranus rings from joint analysis of high quality Earth-based data and the complete set of Voyager occultation measurements; (2) a comprehensive search for weak normal modes excited in the Uranian rings, analogous to the m = 2 and m = 0 normal modes previously identified for the delta and gamma rings; (3) an ongoing search for faint rings and ring arcs of Uranus, using both Voyager images of the rings and Earth-based and spacecraft stellar occultation data; (4) a comparison of upper stratospheric temperatures of Uranus inferred from Voyager ultraviolet occultations with results of ground-based occultation observations; and (5) observations of the 3 Jul. 1989 Saturn occultation of 28 Sgr.

  6. Using GPS radio occultation data in the study of tropical cyclogenesis

    NASA Astrophysics Data System (ADS)

    Didlake, A. C., Jr.; Kuo, Y. B.; Metcalfe, T.

    2005-12-01

    Numerous studies have examined atmospheric conditions and patterns in tropical cyclogenesis. Although much has been accomplished, a complete understanding of tropical cyclogenesis is hindered by the lack of data in the regions where formation occurs. The GPS (Global Positioning System) radio occultation technique can provide valuable data in key areas. In GPS radio occultation, GPS satellites emit radio signals through the atmosphere that are received by another satellite in a low Earth orbit. Various atmospheric properties are calculated based on the alteration of the signal. This study assessed the value of GPS radio occultation data in the study of tropical cyclogenesis by examining storms of the 2002 Western North Pacific typhoon season. The signature of precursor disturbances to tropical cyclogenesis was determined by analyzing composites of data from the NCEP Aviation (AVN) analysis over four days. Similar composites of GPS radio occultation data were produced. The AVN analysis showed strong signals of precursor disturbances in the low-level wind fields and atmospheric refractivity. The GPS radio occultation data detected similarly increased refractivity values in corresponding regions, but had sizeable measurement differences with the AVN analysis. These differences were attributed to AVN analysis error due to the lack of input observational data and the high accuracy of GPS radio occultation measurements. Further comparisons showed that with the limited quantity of data currently available, GPS radio occultation by itself was not sufficient to detect precursor disturbances. It can best be used in data assimilation to improve the analysis and forecasts of tropical storms.

  7. [Prediction of occult carcinoma in contralateral nodules based on the ultrasonic features of unilateral papillary thyroid carcinoma].

    PubMed

    Yang, L M; Li, Q; Zhao, B W; Lyu, J G; Xu, H S; Xu, L L; Li, S Y; Gao, L; Zhu, J

    2017-04-07

    Objective: To investigate the occurrence of occult carcinoma in contralateral lobes based on the ultrasonic features of unilateral papillary thyroid carcinoma. Methods: The study included 202 consecutives cases of unilateral papillary thyroid carcinoma with benign nodules in the contralateral lobe identified by preoperative ultrasound or fine-needle aspiration from June 2014 to December 2015. All patients received total thyroidectomies, and with postoperative pathological examination they were divided into two groups, one including 60 cases with positive occult cancer and another one consisting of 142 cases with negative occult cancer. Univariate and multivariate analyses were performed to analyze the sonographic features of unilateral papillary thyroid carcinoma relevant to the occurrence of occult carcinoma in the contralateral nodules. Results: Univariate analysis indicated occult carcinoma in the contralateral lobes was associated with Hashimoto's thyroiditis(χ(2)=3.955, P =0.047), unclear border (χ(2)=4.375, P =0.036)and multifocality in the ipsilateral(χ(2)=7.375, P =0.007), but not with tumors maximum size, location, A/T, shape, internal structure, internal echo, acoustic halo, calcification, capsular invasion and blood flow signal in the lobe with carcinoma on another side. Multivariate analysis showed unclear border ( OR =2.727, P =0.010) and multifocality in the ipsilateral( OR =2.807, P =0.005)of carcinoma were independent predictive factor for contralateral occult PTC. Conclusions: Unclear border and multifocality of PTC in the ipsilateral were closely relevant to the occurrence of occult carcinoma in the contralateral nodules.

  8. Electron densities in the ionosphere of Mars: A comparison of MARSIS and radio occultation measurements

    NASA Astrophysics Data System (ADS)

    Vogt, Marissa F.; Withers, Paul; Fallows, Kathryn; Flynn, Casey L.; Andrews, David J.; Duru, Firdevs; Morgan, David D.

    2016-10-01

    Radio occultation electron densities measurements from the Mariner 9 and Viking spacecraft, which orbited Mars in the 1970s, have recently become available in a digital format. These data are highly complementary to the radio occultation electron density profiles from Mars Global Surveyor, which were restricted in solar zenith angle and altitude. We have compiled data from the Mariner 9, Viking, and Mars Global Surveyor radio occultation experiments for comparison to electron density measurements made by Mars Advanced Radar for Subsurface and Ionosphere Sounding (MARSIS), the topside radar sounder on Mars Express, and MARSIS-based empirical density models. We find that the electron densities measured by radio occultation are in generally good agreement with the MARSIS data and model, especially near the altitude of the peak electron density but that the MARSIS data and model display a larger plasma scale height than the radio occultation profiles at altitudes between the peak density and 200 km. Consequently, the MARSIS-measured and model electron densities are consistently larger than radio occultation densities at altitudes 200-300 km. Finally, we have analyzed transitions in the topside ionosphere, at the boundary between the photochemically controlled and transport-controlled regions, and identified the average transition altitude, or altitude at which a change in scale height occurs. The average transition altitude is 200 km in the Mariner 9 and Viking radio occultation profiles and in profiles of the median MARSIS radar sounding electron densities.

  9. Stellar occultation candidates from the guide star catalog. I - Saturn, 1991-1999

    NASA Technical Reports Server (NTRS)

    Bosh, A. S.; Mcdonald, S. W.

    1992-01-01

    A list of 203 potential occultations by Saturn and its ring of stars from the HST Guide Star Catalog (GSC) during the years 1991-1999 is presented. This list features many fainter candidates than do current occultation candidate lists for Saturn; these fainter stars can also provide a high signal-to-noise ratio if observed with a large telescope or in the IR where Saturn and its rings have absorption bands. The occultation circumstances are listed, as well as star information found in the GSC.

  10. Study of the technique of stellar occultation

    NASA Technical Reports Server (NTRS)

    Hays, P. B.; Graves, M. E.; Roble, R. G.; Shah, A. N.

    1973-01-01

    The results are reported of a study of the stellar occultation technique for measuring the composition of the atmosphere. The intensity of starlight was monitored during the occultation using the Wisconsin stellar ultraviolet photometers aboard the Orbiting Astronomical Observatory (OAO-A2). A schematic diagram of an occultation is shown where the change in intensity at a given wavelength is illustrated. The vertical projection of the attenuation region is typically 60 km deep for molecular oxygen and 30 km deep for ozone. Intensity profiles obtained during various occultations were analyzed by first determining the tangential columm density of the absorbing gases, and then Abel inverting the column densities to obtain the number density profile. Errors are associated with each step in the inversion scheme and have been considered as an integral part of this study.

  11. Structure of the Atmosphere of Saturn at Low Latitudes: Results from the First Six Cassini Radio Occultation Experiments

    NASA Astrophysics Data System (ADS)

    Schinder, P. J.; Flasar, F. M.; Kliore, A. J.; Rappaport, N. J.; Asmar, S.; Anabtawi, A.; Barbinis, E.; Fleischman, D. U.; Goltz, G. L.; Johnston, D. V.; Rochblatt, D.; French, R. G.; McGhee, C. A.; Marouf, E. A.

    2005-08-01

    On May 3, 2005 occurred the first of a series of seven occultations of Cassini by Saturn which have taken or will take place during the spring and summer of 2005. These near diametric occultations cover a latitude range of between 8 N and 10 S planetocentric latitude, and will give us a detailed look at the structure of the low latitude neutral atmosphere of Saturn down to ˜ 1.6 \\ bar. These occultations are the first to be done at three wavelengths (S, X, and Ka bands) simultaneously. Preliminary results of the occultations that have occurred to date show abundant small scale structure in the temperature-pressure profiles, and a recurring temperature inversion starting at about 100 mbar and extending to roughly 200 mbar.

  12. Occult cancer detection in patients with hemostatic disorder and venous thromboembolism.

    PubMed

    Husseinzadeh, Holleh; Carrier, Marc

    2018-03-01

    There are physiologic ties between Von Willebrand Factor (VWF) and circulating tumor cells. VWF appears to play a role in tumor biology, but it is unclear whether cancer behavior differs in Von Willebrand Disease. In patients presenting with venous thromboembolism (VTE), occult cancer is frequently considered as an underlying cause. The prevalence of occult cancer after provoked VTE is low (3%); therefore, cancer screening in these patients is not routinely recommended. In those with unprovoked VTE, occult cancer is more prevalent, estimated between 4 and 10%. Due to this elevated risk, occult cancer screening is recommended in this population. Multiple studies have investigated whether a "limited" approach (including history and physical exam, basic labs, and chest X-ray) versus "extensive" approach (addition of advanced imaging, such as computer tomography) is more effective. Current data fails to demonstrate extensive screening strategies diagnose more occult cancer, miss fewer cancers during follow up, or improve cancer-related mortality. Furthermore, many patients may be needlessly exposed to unnecessary diagnostic procedures with their associated complications and costs, as well as significant anxiety. Therefore, the decision to perform additional testing should be made on a case-by-case basis. Additional studies are needed to identify subgroups of patients with unprovoked VTE at highest risk for occult cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Portable high speed photometry systems for observing occultations

    NASA Astrophysics Data System (ADS)

    Elliot, J. L.; Dunham, E. W.

    1986-09-01

    Ring orbit studies for Uranus have been particularly fruitful because of the ability, through occultations, to obtain data of high spatial resolution at the rate of 1 to 2 times per year. The occultation program at M.I.T. involves: (1) identifying the scientific questions that can be answered by occultation events, (2) predicting the zone of visibility for the useful events, (3) maintaining and improving a set of portable high-speed photometric systems, (4) obtaining the observations, and (5) reducing the data and interpreting the results. Two stellar occultations by Uranus occurred in May 1985, and were observed with a network of large telescopes that encompassed the Northern and Southern Hemispheres. Portable quartz-oscillator time standards were used at all observatories, and were calibrated before and after each event. Observations obtained form Cerro Tololo and McDonald Observatories of the 4 May and 24 May 1985 occultations by the Uranian rings clearly show a companion to the delta ring on both the immersion and emersion traces. The occultation by Ceres that occurred on 12 November 1984 was observed. Preliminary results give a mean diameter of 933 + or - 10 km, which implies a geometric albedo, Pv = 0.07 + or - 0.01 and a density 2.7 + or - 0.3 gm cu/cm. Hence Ceres is likely composed of silicate material throughout.

  14. Astrometry of Single-Chord Occultations: Application to the 1993 Triton Event

    NASA Technical Reports Server (NTRS)

    Olkin, Catherine B.; Elliot, J. L.; Bus, Schelte J.; McDonald, Stephen W.; Dahn, Conrad C.

    1996-01-01

    This paper outlines a method for reducing astrometric data to derive the closest approach time and distance to the center of an occultation shadow for a single observer. The method applies to CCD frames, strip scans or photographic plates and uses a set of field stars of unknown positions to define a common coordinate system for all frames. The motion of the occulting body is used to establish the transformation between this common coordinate system and the celestial coordinate system of the body's ephemeris. This method is demonstrated by application to the Tr6O occultation by Triton on 1993 July 10 UT. Over an interval of four nights that included the occultation time, 80 frames of Triton and Tr6O were taken near the meridian with the U.S. Naval Observatory (USNO) 61-inch astrometric reflector. Application of the method presented here to these data yields a closest approach distance of 359 +/- 133 km (corresponding to 0.017 +/- 0.006 arcsec) for the occultation chord obtained with the Kuiper Airborne Observatory (KAO). Comparison of the astrometric closest approach time with the KAO light-curve midtime shows a difference of 2.2 +/- 4.1 s. Relative photometry of Triton and Tr6O, needed for photometric calibration of the occultation light curve, is also presented.

  15. Do X-ray-occult fractures play a role in chronic pain following a whiplash injury?

    PubMed

    Hertzum-Larsen, Rasmus; Petersen, Henrik; Kasch, Helge; Bendix, Tom

    2014-08-01

    Whiplash trauma in motor vehicle accidents (MVA) may involve various painful soft tissue damages, but weeks/months later a minority of victims still suffers from various long-lasting and disabling symptoms, whiplash-associated disorders (WAD). The etiology is currently unknown, but X-ray-occult fractures may be one cause in some cases. The purpose of this prospective study was to examine the association between occult fractures, as seen on bone single photon emission computed tomography (SPECT), with neck-, head- and arm pain. An inception cohort of 107 patients presenting with acute whiplash symptoms following an MVA was invited to have a cervical SPECT shortly post injury and again 6 months later. Associations between occult fractures and pain levels at baseline, 6 and 12 months of follow-up were analyzed. Eighty-eight patients had baseline SPECT performed at median 15 days (range 3-28) post injury, but only 49 patients accepted to have the follow-up SPECT at 6 months. Abnormal SPECT, defined as minimum one area of focal uptake, was seen in 32 patients at baseline, reflecting an occult fracture. Occult fractures were not associated with pain levels, neither at baseline nor at follow-up. Occult fractures do not seem to play a role for development of chronic pain after whiplash.

  16. Cassini UVIS solar occultations by Saturn's F ring and the detection of collision-produced micron-sized dust

    NASA Astrophysics Data System (ADS)

    Becker, Tracy M.; Colwell, Joshua E.; Esposito, Larry W.; Attree, Nicholas O.; Murray, Carl D.

    2018-05-01

    We present an analysis of eleven solar occultations by Saturn's F ring observed by the Ultraviolet Imaging Spectrograph (UVIS) on the Cassini spacecraft. In four of the solar occultations we detect an unambiguous signal from diffracted sunlight that adds to the direct solar signal just before or after the occultations occur. The strongest detection was a 10% increase over the direct signal that was enabled by the accidental misalignment of the instrument's pointing. We compare the UVIS data with images of the F ring obtained by the Cassini Imaging Science Subsystem (ISS) and find that in each instance of an unambiguous diffraction signature in the UVIS data, the ISS data shows that there was a recent disturbance in that region of the F ring. Similarly, the ISS images show a quiescent region of the F ring for all solar occultations in which no diffraction signature was detected. We therefore conclude that collisions in the F ring produce a population of small ring particles that can produce a detectable diffraction signal immediately interior or exterior to the F ring. The clearest example of this connection comes from the strong detection of diffracted light in the 2007 solar occultation, when the portion of the F ring that occulted the Sun had suffered a large collisional event, likely with S/2004 S 6, several months prior. This collision was observed in a series of ISS images (Murray et al., 2008). Our spectral analysis of the data shows no significant spectral features in the F ring, indicating that the particles must be at least 0.2 μm in radius. We apply a forward model of the solar occultations, accounting for the effects of diffracted light and the attenuated direct solar signal, to model the observed solar occultation light curves. These models constrain the optical depth, radial width, and particle size distribution of the F ring. We find that when the diffraction signature is present, we can best reproduce the occultation data using a particle population with an average effective particle size of less than 300 μm, while occultations without clear diffraction signals are best modeled using a population with an effective particle size larger than 400 μm.

  17. The impact of the number of occult metastatic lymph nodes on postoperative relapse of resectable esophageal cancer.

    PubMed

    Morimoto, J; Tanaka, H; Ohira, M; Kubo, N; Muguruma, K; Sakurai, K; Yamashita, Y; Maeda, K; Sawada, T; Hirakawa, K

    2014-01-01

    Clinical stage II/III esophageal cancer (EC), as defined by the Japanese Classification, relapses at a moderately high rate even after curative resection. The number of lymph node metastases is known to be associated with tumor relapse. Recently, the prognostic significance of occult metastatic lymph nodes (MLNs), as well as that of overt MLNs, has been reported. The aim of this study was to investigate the impact of the total number of MLNs including occult MLNs on postoperative relapse in clinical stage II/III EC. One hundred and five patients with clinical stage II/III EC who underwent esophagectomy accompanied by radical lymphadenectomy at the Department of Surgical Oncology in Osaka City University Hospital between January 2000 and October 2008 were included in this study. Occult MLNs, metastases not detected by hematoxylin-eosin staining, were identified by immunohistochemistry (IHC) using antipancytokeratin antibody AE1/AE3. The clinicopathological features of occult MLNs were compared between the relapse and no relapse groups. A total of 6558 lymph nodes (1357 from two-field dissection and 5201 from three-field dissection) were examined by IHC staining; 362 overt MLNs and 143 occult MLNs were detected. The number of occult MLNs increased in proportion to the International Union Against Cancer pathological (p)N-status and pStage. When the number of occult MLNs was added to the number of pNs, the number of total MLNs was associated with postoperative relapse. With respect to tumor, node, metastasis stage, 6 of 22 patients (27%) who were pathological node-negative converted to node-positive by considering total MLNs. The number of N3 patients with relapse increased markedly with restaging by total MLNs. The number of total MLNs, but not overt MLNs, was an independent prognostic factor on multivariate analysis. These results suggest that occult MLNs were often found, and they were associated with postoperative relapse of resectable esophageal cancer. The total number of MLNs including occult MLNs could contribute to evaluating the precise stage of patients with esophageal cancer. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  18. Comparing different Ultraviolet Imaging Spectrograph (UVIS) occultation observations using modeling of water vapor jets

    NASA Astrophysics Data System (ADS)

    Portyankina, Ganna; Esposito, Larry W.; Hansen, Candice; Aye, Klaus-Michael

    2016-10-01

    Motivation: On March 11, 2016 the Cassini UVIS observed its 6th star occultation by Enceladus' plume. This observation was aimed to determine variability in the total gas flux from the Enceladus' southern polar region. The analysis of the received data suggests that the total gas flux is moderately increased comparing to the average gas flux observed by UVIS from 2005 to 2011 [1]. However, UVIS detected variability in individual jets. In particular, Baghdad 1 is more collimated in 2016 than in 2005, meaning its gas escapes at higher velocity.Model and fits: We use 3D DSMC model for water vapor jets to compare different UVIS occultation observations from 2005 to 2016. The model traces test articles from jets' sources [2] into space and results in coordinates and velocities for a set of test particles. We convert particle positions into the particle number density and integrate along UVIS line of sight (LoS) for each time step of the UVIS observation using precise observational geometry derived from SPICE [3]. We integrate all jets that are crossed by the LoS and perform constrained least-squares fit of resulting modeled opacities to the observed data to solved for relative strengths of jets. The geometry of each occultation is specific, for example, during solar occultation in 2010 UVIS LoS was almost parallel to tiger stripes, which made it possible to distinguish jets venting from different tiger stripes. In 2011 Eps Orionis occultation LoS was perpendicular to tiger stripes and thus many of the jets were geometrically overlapping. Solar occultation provided us with the largest inventory of active jets - our model fit detects at least 43 non-zero jet contributions. Stellar occultations generally have lower temporal resolution and observe only a sub-set of these jets: 2011 Eps Orionis needs minimum 25 non-zero jets to fit UVIS data. We will discuss different occultations and models fits, including the most recent Epsilon Orionis occultation of 2016.[1] Hansen et al., DPS 48, 2016 [2] Porco et al. 2014 The Astronomical Journal 148, 4 [3] Acton, C.H., 1996 PSS 44, 65-70

  19. Occult Klebsiella pneumoniae bacteremia at emergency department: A single center experience.

    PubMed

    Chang, Eileen Kevyn; Kao, Kai-Liang; Tsai, Mao-Song; Yang, Chia-Jui; Huang, Yu-Tsung; Liu, Chia-Ying; Liao, Chun-Hsing

    2015-12-01

    Patients with undetected bacteremia when discharged from a hospital are considered to have occult bacteremia. Klebsiella pneumoniae bacteremia (KPB) is endemic to Taiwan. Our purpose was to study the impact of occult KPB. We retrospectively reviewed the records of patients who were discharged from our emergency department (ED) and subsequently diagnosed with KPB (occult bacteremia), from January 2008 to March 2014. All patients are followed for at least 3 months after the index ED visit. The study group was compared to KPB patients who were directly hospitalized (DH) from ED in 2008. Thirty-day mortality was the primary endpoint. A total of 913 patients were admitted to our ED with KPB, and 88 of these patients (9.6%) had occult KPB. Among them, 43 had second ED visit and 41 were admitted. The overall 30-day mortality was 2.3%. Relative to patients with occult KPB, DH patients had more respiratory tract infections (p < 0.001) but fewer other intra-abdominal infections (p = 0.015). Liver abscess was the major diagnosis for the second ED visit (37.2%). DH patients had significantly greater 30-day mortality than that of overall patients with KPB (19.2% vs.2.3%, p < 0.001). Most patients with occult KPB had favorable outcomes, but about half of them required a second ED visit. Clinicians should aggressively follow patients with occult KPB and should seek to identify the focus of infection in this endemic area. Copyright © 2015. Published by Elsevier B.V.

  20. Review: Occult hepatitis C virus infection: still remains a controversy.

    PubMed

    Vidimliski, Pavlina Dzekova; Nikolov, Igor; Geshkovska, Nadica Matevska; Dimovski, Aleksandar; Rostaing, Lionel; Sikole, Aleksandar

    2014-09-01

    Occult hepatitis C virus (HCV) infection is characterized by the presence of HCV RNA in the liver cells or peripheral blood mononuclear cells of the patients whose serum samples test negative for HCV RNA, with or without presence of HCV antibodies. The present study reviews the existing literature on the persistence of occult hepatitis C virus infection, with description of the clinical characteristics and methods for identification of occult hepatitis C. Occult hepatitis C virus infection was detected in patients with abnormal results of liver function tests of unknown origin, with HCV antibodies and HCV RNA negativity in serum, and also in patients with spontaneous or treatment-induced recovery from hepatitis C. The viral replication in the liver cells and/or peripheral blood mononuclear cells was present in all clinical presentations of occult hepatitis C. The peripheral blood mononuclear cells represent an extra-hepatic site of HCV replication. The reason why HCV RNA was not detectable in the serum of patients with occult hepatitis C, could be the low number of circulating viral particles not detectable by the diagnostic tests with low sensitivity. It is uncertain whether occult hepatitis C is a different clinical entity or just a form of chronic hepatitis C virus infection. Data accumulated over the last decade demonstrated that an effective approach to the diagnosis of HCV infection would be the implementation of more sensitive HCV RNA diagnostic assays, and also, examination of the presence of viral particles in the cells of the immune system. © 2014 Wiley Periodicals, Inc.

  1. Distribution of the GNSS-LEO occultation events over Egypt

    NASA Astrophysics Data System (ADS)

    Ghoniem, Ibrahim; Mousa, Ashraf El-Kutb; El-Fiky, Gamal

    2017-06-01

    The space-based GNSS RO technique is a promising tool for monitoring the Earth's atmosphere and ionosphere (Mousa et al., 2006). The current paper presents the distribution of the occultation events over Egypt using the operating LEO satellites and GNSS by its two operating systems. By the present research, Egypt could raise NWP Models efficiency by improving meteorological data quality. Twenty operating LEO missions (e.g. Argentinean SAC-C, European MetOp-A, German TerraSAR-X, Indian OceanSat-2, etc.) sent by different countries all over the world were used to derive the occultation events position through Egypt borders by receiving signal from the American global positioning system (GPS) and the Russian global navigation satellite system (GLONASS). Approximately 20,000 km Altitude satellites are transmitting enormous number of rays by the day to approximately 800 km satellites passing by the Earth atmosphere. Our mission is to derive all of these rays position (start and end) by calculating satellites position by the time, determine the rays in the occultation case and derive the atmosphere tangent point position for all occultating rays on the Earth surface (Occultation Events).

  2. Radio Occultation Measurements of Pluto’s Atmosphere with New Horizons

    NASA Astrophysics Data System (ADS)

    Hinson, David P.; Linscott, Ivan; Tyler, Len; Bird, Mike; Paetzold, Martin; Strobel, Darrell; Summers, Mike; Woods, Will; Stern, Alan; Weaver, Hal; Olkin, Cathy; Young, Leslie; Ennico, Kimberly; Gladstone, Randy; Greathouse, Tommy; Kammer, Josh; Parker, Alex; Parker, Joel; Retherford, Kurt; Schindhelm, Eric; Singer, Kelsi; Steffl, Andrew; Tsang, Con; Versteeg, Maarten

    2015-11-01

    The reconnaissance of the Pluto System by New Horizons included radio occultations at both Pluto and Charon. This talk will present the latest results from the Pluto occultation. The REX instrument onboard New Horizons received and recorded uplink signals from two 70-m antennas and two 34-m antennas of the NASA Deep Space Network - each transmitting 20 kW at 4.2-cm wavelength - during a diametric occultation by Pluto. At the time this was written only a short segment of data at occultation entry (193°E, 17°S) was available for analysis. The REX measurements extend unequivocally to the surface, providing the first direct measure of the surface pressure and the temperature structure in Pluto’s lower atmosphere. Data from occultation exit (16°E, 15°N) are scheduled to arrive on the ground in late August 2015. Those observations will yield an improved estimate of the surface pressure, a second temperature profile, and a measure of the diameter of Pluto with a precision of a few hundred meters. This work is supported by the NASA New Horizons Mission.

  3. Radio Occultation Measurements of Pluto's Atmosphere with New Horizons

    NASA Astrophysics Data System (ADS)

    Hinson, D. P.; Linscott, I.; Tyler, G. L.; Bird, M. K.; Paetzold, M.; Strobel, D. F.; Summers, M. E.; Woods, W. W.; Stern, A.; Weaver, H. A., Jr.; Olkin, C.; Young, L. A.; Ennico Smith, K.; Gladstone, R.; Greathouse, T.; Kammer, J.; Parker, A. H.; Parker, J. W.; Retherford, K. D.; Schindhelm, E.; Singer, K. N.; Steffl, A.; Tsang, C.; Versteeg, M.

    2015-12-01

    The reconnaissance of the Pluto System by New Horizons included radio occultations at both Pluto and Charon. This talk will present the latest results from the Pluto occultation. The REX instrument onboard New Horizons received and recorded uplink signals from two 70-m antennas and two 34-m antennas of the NASA Deep Space Network - each transmitting 20 kW at 4.2-cm wavelength - during a diametric occultation by Pluto. At the time this was written only a short segment of data at occultation entry (193°E, 17°S) was available for analysis. The REX measurements extend unequivocally to the surface, providing the first direct measure of the surface pressure and the temperature structure in Pluto's lower atmosphere. Preliminary analysis yields a surface pressure of about 10 microbars, smaller than expected. Data from occultation exit (16°E, 15°N) are scheduled to arrive on the ground in late August 2015. Those observations will yield an improved estimate of the surface pressure, a second temperature profile, and a measure of the diameter of Pluto with a precision of a few hundred meters.

  4. Recent progress on external occulter technology for imaging exosolar planets

    NASA Astrophysics Data System (ADS)

    Kasdin, N. J.; Vanderbei, R. J.; Sirbu, D.; Samuels, J.; Shaklan, S.; Lisman, D.; Thomson, M.; Cady, E.; Martin, S.

    Imaging planets orbiting nearby stars requires a system for suppressing the host starlight by at least ten orders of magnitude. One such approach uses an external occulter, a satellite flying far from the telescope and employing a large screen, or starshade, to suppress the incoming starlight. This trades the added complexity of building the precisely shaped starshade and flying it in formation against simplifications in the telescope since extremely precise wavefront control is no longer necessary. Much progress has been made recently in designing, testing and manufacturing starshade technology. In this paper we describe the design of starshades and report on recent accomplishments in manufacturing and measuring a prototype occulter petal as part of NASA's first Technology Development for Exoplanet Missions (TDEM) program. We demonstrate that the as-built petal is consistent with a full-size occulter achieving better than 10-10 contrast. We also discuss laboratory testing at the Princeton Occulter Testbed. These experiments use sub-scale, long-distance beam propagation to verify the diffraction analysis associated with occulter starlight suppression. We demonstrate roughly 10-10 suppression in the laboratory and discuss the important challenges and limitations.

  5. Experiment D005: Star occultation navigation

    NASA Technical Reports Server (NTRS)

    Silva, R. M.; Jorris, T. R.; Vallerie, E. M., III

    1971-01-01

    The usefulness of star occultation measurements for space navigation and the determination of a horizon density profile which could be used to update atmospheric models for horizon-based measurement systems were studied. The time of occultation of a known star by a celestial body, as seen by an orbiting observer, determines a cylinder of position, the axis of which is the line through the star and the body center, and the radius of which is equal to the occulting-body radius. The dimming percentage, with respect to the altitude of this grazing ray from the star to the observer, is a percentage altitude for occultation. That is, the star can be assumed to be occulted when it reaches a predetermined percentage of its unattenuated value. The procedure used was to measure this attenuation with respect to time to determine the usefulness of the measurements for autonomous space navigation. In this experiment, the crewmembers had to accomplish star acquisition, identification, calibration, and tracking. Instrumentation was required only for measurement of the relative intensity of the star as it set into the atmosphere.

  6. Earth rotation derived from occultation records

    NASA Astrophysics Data System (ADS)

    Sôma, Mitsuru; Tanikawa, Kiyotaka

    2016-04-01

    We determined the values of the Earth's rotation parameter, ΔT = T T - UT, around AD 500 after confirming that the value of the tidal acceleration, dot{n}, of the lunar motion remained unchanged during the period between ancient times and the present. For determining of ΔT, we used contemporaneous occultations of planets by the Moon. In general, occultation records are not useful. However, there are some records that give us a stringent condition for the range of ΔT. Records of the lunar occultations in AD 503 and AD 513 are such examples. In order to assure the usefulness of this occultation data, we used contemporaneous annular and total solar eclipses, which have not been used in the preceding work. This is the first work in which the lunar occultation data have been used as primary data to determine the value of ΔT together with auxiliary contemporaneous annular and total solar eclipses. Our ΔT value is less than a smoothed value (Stephenson 1997) by at least 450 s. The result is consistent with our earlier results obtained from solar eclipses.

  7. Occultation Lightcurves for Selected Pluto Volatile Transport Models

    NASA Astrophysics Data System (ADS)

    Young, L. A.

    2004-11-01

    The stellar occultations by Pluto in 1988 and 2002 are demonstrably sensitive to changes in Pluto's atmosphere near one microbar (Elliot and Young 1992, AJ 103, 991; Elliot et al. 2003, Nature 424, 165; Sicardy 2003, Nature 424, 168). However, Pluto volatile-transport models focus on the changes in the atmospheric pressure at the surface (e.g., Hansen and Paige 1996, Icarus 20, 247; Stansberry and Yelle 1999, Icarus 141, 299). What's lacking is a connection between predictions about the surface properties and either temperature and pressure profiles measurable from stellar occultations, or the occultation light curve morphology itself. Radiative-conductive models can illuminate this connection. I will illustrate how Pluto's changing surface pressure, temperature, and heliocentric distance may affect occultation light curves for a selection of existing volatile transport models. Changes in the light curve include the presence or absence of an observable ``kink'' (or departure from an isothermal light curve), the appearance of non-zero minimum flux levels, and the detectability of the solid surface. These light curves can serve as examples of what we may anticipate during the upcoming Pluto occultation season, as Pluto crosses the galactic plane.

  8. New Occultation Systems and the 2005 July 11 Charon Occultation

    NASA Astrophysics Data System (ADS)

    Young, L. A.; French, R. G.; Gregory, B.; Olkin, C. B.; Ruhland, C.; Shoemaker, K.; Young, E. F.

    2005-08-01

    Charon's density is an important input to models of its formation and internal structure. Estimates range from 1.59 to 1.83 g/cm3 (Olkin et al. 2003. Icarus 164, 254), with Charon's radius as the main source of uncertainty. Reported values of Charon's radius from mutual events range from 593±13 (Buie et al. 1992, Icarus 97, 211) to 621±21 km (Young & Binzel 1994, Icarus 108), while an occultation observed from a single site gives a lower limit on the radius of 601.5 km (Walker 1980 MNRAS 192, 47; Elliot & Young 1991, Icarus 89, 244). On 2005 July 11 UT (following this abstract submission date), Charon is predicted to occult the star C313.2. If successful, this event will be the first Charon occultation observed since 1980, and the first giving multiple chords across Charon's disk. This event is expected to measure Charon's radius to 1 km. Our team is observing from three telescopes in Chile, the 4.0-m Blanco and the 0.9-m telescopes at Cerro Tololo and the 4.2-m SOAR telescope at Cerro Pachon. At SOAR, we will be using the camera from our new PHOT systems (Portable High-speed Occultation Telescopes). The PHOT camera is a Princeton Instrument MicroMAX:512BFT from Roper Scientific, a 512×512 frame-transfer CCD with a readnoise of only 3 electrons at the 100 kHz digitization rate. The camera's exposures are triggered by a custom built, compact, stand-alone GPS-based pulse-train generator. A PHOT camera and pulse-train generator were used to observe the occultation of 2MASS 1275723153 by Pluto on 2005 June 15 UT from Sommers-Bausch Observatory in Boulder Colorado; preliminary analysis shows this was at best a grazing occultation from this site and a successful engineering run for the July 11 Charon occultation. The work was supported, in part, by NSF AST-0321338 (EFY) and NASA NNG-05GF05G (LAY).

  9. Prevalence of colorectal diseases in immunological fecal occult blood test (I-FOBT) positive patients in a tertiary care hospital in Bangladesh.

    PubMed

    Mollick, S H; Roy, P K; Bhuiyan, M R; Mia, A R; Alam, M S; Mollick, K A; Pervin, S; Hassan, M Q

    2014-10-01

    Bleeding lesion anywhere in the GI tract can cause positive reaction to Immunological Fecal Occult Blood Test (FOBT). Although any colonic lesion can cause occult lower GI bleeding, relative frequency of this lesion not known. Guaic based tests require prior preparation and dietary restriction and less sensitive and specific than IFOBT for detection of occult bleeding .IFOBT is specific for human hemoglobin and is more sensitive and specific for detection of occult bleeding from any colonic lesion. Aim of this study was to diagnose occult gastrointestinal bleeding with positive IFOBT and the prevalence of colorectal disease in IFOBT positive patients in a tertiary care hospital in Bangladesh. This was a prospective cross sectional study conducted in Department of gastroenterology in collaboration with clinical pathology, BSMMU, Dhaka during the period of January 2009 to December 2009. In this study 200 patients meeting the inclusion criteria were included. Detailed clinical history and physical findings were recorded; FOBT was done on single stool specimen. Positive occult bleeding was confirmed in 90 patients of whom 80 patients underwent colonoscopy. The mean age of study population was 36.73±13.64 (range 16 to 72) years. At colonoscopy lesion were identified in 46(57.50%) patients, of which colonic polyp in12 (15%), colorectal cancer in 11(13.7%), inflammatory bowel disease in 3(3.75%), hemorrhoids and anal fissure in 7(8.75%), tuberculosis in 5(6.25%), and proctitis in 1(1.25%) cases. A positive IFOBT is more sensitive and specific test than other FOBT for detection of occult lower GI bleeding of colonic origin. In this study colorectal diseases were detected in 57.50% of the IFOBT positive patients, so IOBT can be used as an important diagnostic tool for detection of occult lower GI bleeding.

  10. Relationship between occult hepatitis B virus infection and chronic kidney disease in a Chinese population-based cohort.

    PubMed

    Kong, Xiang-Lei; Ma, Xiao-Jing; Su, Hong; Xu, Dong-Mei

    2016-03-01

    Previous studies have revealed inconsistent results regarding the association between occult hepatitis B virus (HBV) infection and chronic kidney disease (CKD). Therefore, we conducted a prospective cohort study to evaluate the association between occult HBV infection and CKD. A total of 4329 adults, aged 46.2 ± 13.7 years, without CKD at baseline were enrolled while undergoing physical examinations. Occult HBV infection was defined as seropositivity for antibody to HBV core antigen. CKD was defined as decreased estimated glomerular filtration rate (eGFR < 60 ml·min -1 ·1.73 m -2 ) or presence of proteinuria ≥1+, assessed using a repeated dipstick method. eGFR was computed using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation. The prevalence of occult HBV infection was 8.1% (352/4329). During 5 years of follow-up, 165 patients (3.8%) developed CKD. Univariate Logistic regression analysis showed that occult HBV infection was positively associated with decreased eGFR, with an odds ratio ( OR ) of 2.15 (95% confidence interval ( CI ): 1.05-4.11). In contrast, occult HBV infection was not associated with either proteinuria or CKD ( P  > 0.05). After adjustment for potential confounders in the multivariate Logistic regression analysis, age, hypertension, diabetes, and the highest quartile of uric acid were associated with CKD, with OR s of 1.04 (95% CI : 1.02-1.05), 2.1 (95% CI : 1.46-3.01), 2.02 (95% CI : 1.36-2.99), and 1.86 (95% CI : 1.17-2.95), respectively. However, occult HBV infection was not associated with CKD, with an OR of 1.12 (95% CI : 0.65-1.95). This study did not find an association between occult HBV infection and CKD. However, high-risk patients infected with HBV should still be targeted for monitoring for the development of CKD.

  11. Heparin as a pharmacologic intervention to induce positive scintiscan in occult gastrointestinal bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaudhuri, T.K.; Brantly, M.

    1984-04-01

    The value of using heparin as a pharmacologic intervention to induce a positive scintiscan was studied in a patient with chronic occult gastrointestinal bleeding. When all standard diagnostic tests (upper and lower gastrointestinal series, upper and lower endoscopy, and conventional noninterventional Tc-99m RBC imaging) fail to detect and localize gastrointestinal bleeding in a patient who has definite clinical evidence (guaiac positive stool and dropping hemoglobin, hematocrit) of chronic occult gastrointestinal oozing, heparin may be used (with proper precaution) as a last resort to aid in the scintigraphic detection and localization of chronic occult gastrointestinal bleeding.

  12. Earth Occultation Monitoring with the Fermi Gamma Ray Burst Monitor

    NASA Technical Reports Server (NTRS)

    Wilson-Hodge, Colleen A.

    2014-01-01

    Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique (EOT). Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors for daily monitoring. Light curves, updated daily, are available on our website http://heastro.phys.lsu.edu/gbm. Our software is also capable of performing the Earth occultation monitoring using up to 128 energy bands, or any combination of those bands, using our 128-channel, 4-s CSPEC data. The GBM BGO detectors, sensitive from about 200 keV to 40 keV, can also be used with this technique. In our standard application of the EOT, we use a catalog of sources to drive the measurements. To ensure that our catalog is complete, our team has developed an Earth occultation imaging method. In this talk, I will describe both techniques and the current data products available. I will highlight recent and important results from the GBM EOT, including the current status of our observations of hard X-ray variations in the Crab Nebula.

  13. Biopsy of CT-Occult Bone Lesions Using Anatomic Landmarks for CT Guidance.

    PubMed

    Hillen, Travis J; Talbert, Robert J; Friedman, Michael V; Long, Jeremiah R; Jennings, Jack W; Wessell, Daniel E; Baker, Jonathan C

    2017-07-01

    The purpose of this study is to evaluate the histopathologic diagnostic yield, sample size, procedural time, and dose-length product (DLP) for the biopsy of CT-occult lesions found at MRI or PET or both. A retrospective review of our radiology information system for biopsies of CT-occult lesions using CT guidance from January 1, 2010, through December 31, 2014, was performed and compared with a selection of CT-guided biopsies of CT-evident bone lesions during the same period. The data were then evaluated for diagnostic yield of histopathologic diagnosis, procedural time, use of sedation medication, DLP, and size of specimens obtained. A total of 30 CT-occult biopsies met the inclusion criteria. Twenty-seven of those biopsies had results that were concordant with the patient's primary histopathologic diagnosis, imaging findings, and clinical course. In the CT-evident lesion group, concordant histopathologic abnormalities were identified in 27 of 30 patients. There was a statistically significant increase in number of samples obtained for the CT-evident lesions compared with CT-occult lesions. There was no statistically significant difference in total specimen length, DLP, number of CT scans, procedural time, or use of sedation medication between the CT-occult and CT-evident biopsy groups. Biopsy of CT-occult lesions using anatomic landmarks achieves diagnostic yields similar to those for CT-guided biopsy of CT-evident lesions.

  14. Diagnostic strategy for occult hepatitis B virus infection

    PubMed Central

    Ocana, Sara; Casas, Maria Luisa; Buhigas, Ingrid; Lledo, Jose Luis

    2011-01-01

    In 2008, the European Association for the study of the liver (EASL) defined occult hepatitis B virus infection (OBI) as the “presence of hepatitis B virus (HBV) DNA in the liver (with detectable or undetectable HBV DNA in the serum) of individuals testing hepatitis B surface antigen (HBsAg) negative by currently available assays”. Several aspects of occult HBV infection are still poorly understood, including the definition itself and a standardized approach for laboratory-based detection, which is the purpose of this review. The clinical significance of OBI has not yet been established; however, in terms of public health, the clinical importance arises from the risk of HBV transmission. Consequently, it is important to detect high-risk groups for occult HBV infection to prevent transmission. The main issue is, perhaps, to identify the target population for screening OBI. Viremia is very low or undetectable in occult HBV infection, even when the most sensitive methods are used, and the detection of the viral DNA reservoir in hepatocytes would provide the best evaluation of occult HBV prevalence in a defined set of patients. However, this diagnostic approach is obviously unsuitable: blood detection of occult hepatitis B requires assays of the highest sensitivity and specificity with a lower limit of detection < 10 IU/mL for HBV DNA and < 0.1 ng/mL for HBsAg. PMID:21472120

  15. The optimization of the inverted occulter of the solar orbiter/METIS coronagraph/spectrometer

    NASA Astrophysics Data System (ADS)

    Landini, F.; Vives, S.; Romoli, M.; Guillon, C.; Pancrazzi, M.; Escolle, C.; Focardi, M.; Fineschi, S.; Antonucci, E.; Nicolini, G.; Naletto, G.; Nicolosi, P.; Spadaro, D.

    2017-11-01

    The coronagraph/spectrometer METIS (Multi Element Telescope for Imaging and Spectroscopy), selected to fly aboard the Solar Orbiter ESA/NASA mission, is conceived to perform imaging (in visible, UV and EUV) and spectroscopy (in EUV) of the solar corona. It is an integrated instrument suite located on a single optical bench and sharing a unique aperture on the satellite heat shield. As every coronagraph, METIS is highly demanding in terms of stray light suppression. In order to meet the strict thermal requirements of Solar Orbiter, METIS optical design has been optimized by moving the entrance pupil at the level of the external occulter on the S/C thermal shield, thus reducing the size of the external aperture. The scheme is based on an inverted external-occulter (IEO). The IEO consists of a circular aperture on the Solar Orbiter thermal shield. A spherical mirror rejects back the disk-light through the IEO. The experience built on all the previous space coronagraphs forces designers to dedicate a particular attention to the occulter optimization. Two breadboards were manufactured to perform occulter optimization measurements: BOA (Breadboard of the Occulting Assembly) and ANACONDA (AN Alternative COnfiguration for the Occulting Native Design Assembly). A preliminary measurement campaign has been carried on at the Laboratoire d'Astrophysique de Marseille. In this paper we describe BOA and ANACONDA designs, the laboratory set-up and the preliminary results.

  16. Possible occultation by Pluto from US East Coast

    NASA Astrophysics Data System (ADS)

    Waagen, Elizabeth O.

    2012-06-01

    We have been asked to help disseminate the news of a possible occultation by Pluto visible to observers on the US East coast. Although the AAVSO does not ordinarily issue announcements of upcoming occultations, in this case the object is Pluto and the NASA New Horizons mission (http://www.nasa.gov/mission_pages/newhorizons/main/index.html) will be visiting Pluto in 2015. The information below has been supplied by Dr. Leslie Young (Southwest Research Institute), who is coordinating this observing campaign on Pluto. Dr. Young is also Deputy Project Scientist for the New Horizons mission. ALERT: Possible Pluto occultation Wednesday night (2012/06/14 03:28 UT) from US East coast. CONTACT: Leslie Young (layoung@boulder.swri.edu; work: 303-546-6057; skype: drpluto). Also see our planning pages in progress at http://wiki.boulder.swri.edu/mediawiki/index.php/2012-06-14_Pluto_occultation. Pluto's thin, nitrogen atmosphere is in vapor-pressure equilibrium with the surface ice, and changes seasonally. We've seen it double since 1988, and now we measure its pressure once or twice a year. The technique we use is stellar occultation, when a star passes behind Pluto's atmosphere. The atmosphere defocuses the starlight. By the timing of the fading of the star, we measure the pressure and temperature in Pluto's atmosphere at ~10 km resolution. MORE INFORMATION: See http://wiki.boulder.swri.edu/mediawiki/index.php/2012-06-14_Pluto_occultation.

  17. Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA.

    PubMed

    Hasegawa, Kazuhiro; Kabata, Tamon; Kajino, Yoshitomo; Inoue, Daisuke; Tsuchiya, Hiroyuki

    2017-02-01

    Periprosthetic fractures of the acetabulum occurring during primary THA are rare. Periprosthetic occult fractures are defined as those not identified by the surgeon during the procedure which might be missed on a routine postoperative radiograph. However, it is unclear how frequently these fractures occur and whether their presence affects functional recovery. In this study, using routine CT scans that were obtained as part of another primary hip arthroplasty study protocol, we retrospectively assessed (1) the prevalence of occult fractures of the acetabulum occurring during primary THA, (2) the location of occult fractures of the acetabulum during THA, and (3) risk factors contributing to such occult fractures. Between 2004 and 2013, our institute performed 585 primary THAs (cementless or hybrid) in 494 patients with DICOM pre- and postoperative CT; during the period in question, all patients undergoing THA underwent CT before and after surgery. Preoperative CT images were taken as part of a CT-based three-dimensional templating software and navigation system. Postoperative CT images were taken an average of 1 week after surgery as part of a different protocol to evaluate cup position, restoration of leg length and offset, volume of postoperative hematoma to assess anticoagulation effects after THA, and fractures that were not found on routine postoperative radiographs (which we defined as occult fractures). Patients with a history of prior pelvic osteotomy, trauma, and infection were excluded (88 patients/99 hips); 406 patients (102 males and 304 females; 486 hips) form the basis of this report. The mean age of the patients was 60 ± 11 years, with a mean BMI of 23 ± 4 kg/m 2 . The mean followup of the patients with periprosthetic fracture of the acetabulum was 58 ± 28 months (range, 12-131 months). Potential risk factors for occult acetabular fracture including age, sex, BMI, preoperative diagnosis, additional dome screw fixation, composition and size of each cup, and acetabular design were examined in multivariate analysis. Acetabular component designs were categorized as true hemispheric, peripheral self-locking, and elliptical; during the period in question the indications for each cup design were based on the brand of stem used. Comparison between preoperative and postoperative CT images was done to detect the fractures. Patients with fractures identified during surgery were treated with additional dome screw fixation and a 3-week period of nonweightbearing. Patients with occult fractures in this series did not receive additional treatment as we had confirmed secure fixation of the cup during surgery. Occult fractures occurred in 41 hips (8.4%); periprosthetic fractures of the acetabulum were seen during surgery in an additional two hips (0.4%). The superolateral wall was the most frequent location for occult fractures of the acetabulum. After controlling for relevant confounding variables, only the use of peripheral self-locking cups was associated with an increased risk of occult fracture (odds ratio [OR], 2.6 compared with hemispheric cups; 95% CI, 1.2-5.6; p < 0.05). All patients with occult fractures showed bone ingrowth fixation at the final followup, without any additional surgical intervention. Periprosthetic occult fractures of the acetabulum may occur relatively frequently during press-fit impaction. We observed a higher rate of fractures associated with the use of peripheral self-locking components. Occult acetabular fractures not detected on routine postoperative plain films may be ignored if secure fixation of the cup has been confirmed during the operation. Level III, therapeutic study.

  18. ASPIICS/PROBA-3 formation flying solar coronagraph: Stray light analysis and optimization of the occulter

    NASA Astrophysics Data System (ADS)

    Landini, F.; Mazzoli, A.; Venet, M.; Vivès, S.; Romoli, M.; Lamy, P.; Massone, G.

    2017-11-01

    The "Association de Satellites Pour l'Imagerie et l'Interferometrie de la Couronne Solaire", ASPIICS, selected by ESA for the PROBA-3 mission, heralds the next generation of coronagraph for solar research, exploiting formation flying to gain access to the inner corona under eclipse-like conditions for long periods of time. A detailed description of the ASPIICS instrument and of its scientific objectives can be found in [1]. ASPIICS is distributed on the two PROBA 3 spacecrafts (S/C) separated by 150 m. The coronagraph optical assembly is hosted by the "coronagraph S/C" protected from direct solar disk light by the occulting disk on the "occulter S/C". The most critical issue in the design of a solar coronagraph is the reduction of the stray light due to the diffraction and scattering of the solar disk light by the occulter, the aperture and the optics. In the present article, we deal with two of these issues: - The analysis of the stray light inside the telescope. - The optimization of the external occulter edge, in order to eliminate the Poisson spot behind the occulter and to lower the stray light level going through the entrance pupil of the telescope. This work was performed in the framework of the ESA STARTIGER program which took place at the Laboratoire d'Astrophysique de Marseille (LAM) during a 6-month period from September 2009 to March 2010. In general, it is a very complicated task to combine the above two stray light issues together in the simulation and design phase as it requires to consider the propagation inside the telescope of the light diffracted by the external occulter. Actually, the present literature only reports diffraction calculations performed for simple occulting systems (i.e., two disks and serrated disk). A more pragmatic approach, also driven by the tight schedule of the STARTIGER program, is to separate the two contributions, and perform two different stray light analyses. This paper is dedicated to the description of both analyses: in particular, the first part is dedicated to the evaluation of the stray light inside the telescope, assuming a simple disk as occulter, and a preliminary baffle design is presented; the second part describes the investigation on the geometry of the external occulter, with a detailed description of the laboratory setup that has been designed and implemented to compare together several types of occulting systems.

  19. Occult hepatitis B virus coinfection in HIV-positive African migrants to the UK: a point prevalence study.

    PubMed

    Chadwick, D; Doyle, T; Ellis, S; Price, D; Abbas, I; Valappil, M; Geretti, A M

    2014-03-01

    Occult (surface antigen-negative/DNA-positive) hepatitis B virus (HBV) infection is common in areas of the world where HBV is endemic. The main objectives of this study were to determine the prevalence of occult HBV infection in HIV-infected African migrants to the UK and to determine factors associated with occult coinfection. This anonymized point-prevalence study identified Africans attending three HIV clinics, focussing on patients naïve to antiretroviral therapy (ART). Stored blood samples were tested for HBV DNA. Prevalence was calculated in the entire cohort, as well as in subpopulations. Risk factors for occult HBV coinfection were identified using logistic regression analysis. Among 335 HIV-positive African migrants, the prevalence of occult HBV coinfection was 4.5% [95% confidence interval (CI) 2.8-7.4%] overall, and 6.5% (95% CI 3.9-10.6%) and 0.8% (95% CI 0.2-4.6%) in ART-naïve and ART-experienced patients, respectively. Among ART-naïve anti-HBV core (anti-HBc)-positive patients, the prevalence was 16.4% (95% CI 8.3-25.6%). The strongest predictor of occult coinfection was anti-HBc positivity [odds ratio (OR) 7.4; 95% CI 2.0-27.6]. Median HBV DNA and ALT levels were 54 IU/mL [interquartile range (IQR) 33-513 IU/mL] and 22 U/L (IQR 13-27 U/L), respectively. Occult HBV coinfection remains under-diagnosed in African HIV-infected patients in the UK. Given the range of HBV DNA levels observed, further studies are warranted to determine its clinical significance and to guide screening strategies and ART selection in these patients. © 2013 British HIV Association.

  20. Risk Factors for Predicting Occult Lymph Node Metastasis in Patients with Clinical Stage I Non-small Cell Lung Cancer Staged by Integrated Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography.

    PubMed

    Kaseda, Kaoru; Asakura, Keisuke; Kazama, Akio; Ozawa, Yukihiko

    2016-12-01

    Lymph nodes in patients with non-small cell lung cancer (NSCLC) are often staged using integrated 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT). However, this modality has limited ability to detect micrometastases. We aimed to define risk factors for occult lymph node metastasis in patients with clinical stage I NSCLC diagnosed by preoperative integrated FDG-PET/CT. We retrospectively reviewed the records of 246 patients diagnosed with clinical stage I NSCLC based on integrated FDG-PET/CT between April 2007 and May 2015. All patients were treated by complete surgical resection. The prevalence of occult lymph node metastasis in patients with clinical stage I NSCLC was analysed according to clinicopathological factors. Risk factors for occult lymph node metastasis were defined using univariate and multivariate analyses. Occult lymph node metastasis was detected in 31 patients (12.6 %). Univariate analysis revealed CEA (P = 0.04), SUV max of the primary tumour (P = 0.031), adenocarcinoma (P = 0.023), tumour size (P = 0.002) and pleural invasion (P = 0.046) as significant predictors of occult lymph node metastasis. Multivariate analysis selected SUV max of the primary tumour (P = 0.049), adenocarcinoma (P = 0.003) and tumour size (P = 0.019) as independent predictors of occult lymph node metastasis. The SUV max of the primary tumour, adenocarcinoma and tumour size were risk factors for occult lymph node metastasis in patients with NSCLC diagnosed as clinical stage I by preoperative integrated FDG-PET/CT. These findings would be helpful in selecting candidates for mediastinoscopy or endobronchial ultrasound-guided transbronchial needle aspiration.

  1. Occult urolithiasis in asymptomatic primary hyperparathyroidism.

    PubMed

    Tay, Yu-Kwang Donovan; Liu, Minghao; Bandeira, Leonardo; Bucovsky, Mariana; Lee, James A; Silverberg, Shonni J; Walker, Marcella D

    2018-05-01

    Recent international guidelines suggest renal imaging to detect occult urolithiasis in all patients with asymptomatic primary hyperparathyroidism (PHPT), but data regarding their prevalence and associated risk factors are limited. We evaluated the prevalence and risk factors for occult urolithiasis. Cross-sectional analysis of 96 asymptomatic PHPT patients from a university hospital in the United States with and without occult nephrolithiasis. Occult urolithiasis was identified in 21% of patients. Stone formers had 47% higher 24-hour urinary calcium excretion (p = 0.002). Although available in only a subset of patients (n = 28), activated vitamin D [1,25(OH) 2 D] was 29% higher (p = 0.02) in stone formers. There was no difference in demographics, BMI, calcium or vitamin D intake, other biochemistries, renal function, BMD, or fractures. Receiver operating characteristic curves indicated that urinary calcium excretion and 1,25(OH) 2 D had an area under the curve of 0.724 (p = 0.003) and 0.750 (p = 0.04), respectively. A urinary calcium threshold of >211mg/day provided a sensitivity of 84.2% and a specificity of 55.3% while a 1,25(OH) 2 D threshold of >91pg/mL provided a sensitivity and specificity of 62.5% and 90.0% respectively for the presence of stones. Occult urolithiasis is present in about one-fifth of patients with asymptomatic PHPT and is associated with higher urinary calcium and 1,25(OH) 2 D. Given that most patients will not have occult urolithiasis, targeted imaging in those most likely to have occult stones rather than screening all asymptomatic PHPT patients may be useful. The higher sensitivity of urinary calcium versus 1,25(OH) 2 D suggests screening those with higher urinary calcium may be an appropriate approach.

  2. Prevalence of occult hepatitis C infection in chronic hemodialysis and kidney transplant patients.

    PubMed

    Baid-Agrawal, Seema; Schindler, Ralf; Reinke, Petra; Staedtler, Adrienne; Rimpler, Sunda; Malik, Barbara; Frei, Ulrich; Berg, Thomas

    2014-05-01

    Detection of hepatitis C virus (HCV) RNA in peripheral blood mononuclear cells (PBMC) and/or hepatocytes in absence of HCV RNA in serum, designated as 'occult HCV infection', has been a matter of controversy in recent years. We investigated for the first time the prevalence of occult HCV infection in large cohorts of chronic hemodialysis (CHD) and kidney transplant (KTx) patients. We enrolled 417 CHD patients, 417 KTx recipients and 2 control groups - 25 anti-HCV (antibody against HCV)-positive and HCV RNA-positive patients with chronic hepatitis C, and 40 anti-HCV-, HCV RNA-, and HBsAg-negative healthy subjects. HCV RNA was tested in serum and PBMC using a sensitive commercial assay. In CHD patients, the prevalence of anti-HCV was 3.6% (15/417) and of positive serum HCV RNA 2.4% (10/417). HCV RNA was detected in PBMC in 1/407 (0.25%) HCV serum RNA-negative patients ("occult HCV infection"). In KTx recipients, prevalence of anti-HCV was 4.8% (20/417) and of positive serum HCV RNA 4.6% (19/417). Occult HCV infection was found in 2/398 (0.5%) serum HCV RNA-negative patients. On a mean longitudinal follow-up of 30months of the 3 patients with occult HCV infection, there was no clinical or virological evidence of HCV infection. The prevalence of occult HCV infection was very low in our CHD and KTx patients, and it did not appear to be clinically relevant. Further studies in geographic populations with high HCV endemicity are required to clarify the significance of occult HCV infection in these patient groups. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  3. Prevalence of occult inflammatory bowel disease in ankylosing spondylitis.

    PubMed

    Costello, P B; Alea, J A; Kennedy, A C; McCluskey, R T; Green, F A

    1980-10-01

    Fifty-five patients with ankylosing spondylitis and 16 control patients matched for sex and age were examined for evidence of occult inflammatory bowel disease. In all patients evaluation included history and physical examination, barium enema, sigmoidoscopy, and rectal biopsy. The results of this study suggest that there is no increased prevalence of occult inflammatory bowel disease in patients with ankylosing spondylitis.

  4. Orbital Metastasis: Rare Initial Presentation of an Occult Gall Bladder Carcinoma.

    PubMed

    Jain, Tarun Kumar; Parihar, Ashwin Singh; Sood, Ashwani; Basher, Rajender Kumar; Bollampally, Neeraja; Shekhawat, Amit Singh; Mittal, Bhagwant Rai

    2018-03-01

    Orbital metastases are known to arise from primary breast carcinoma followed by prostate, malignant melanoma, and lung carcinoma. We report a case of orbital metastasis as the initial presentation of an occult primary gall bladder carcinoma. The FDG PET/CT helped in localizing the occult distant primary site, which previously escaped detection, and also enabled the evaluation of orbital metastasis.

  5. The Atmosphere of Titan from Cassini Radio Occultations

    NASA Astrophysics Data System (ADS)

    Schinder, Paul J.; Flasar, F. M.; Marouf, E. A.; French, R. G.; McGhee, C. A.; Kliore, A. J.; Rappaport, N.; Nagy, A. F.; Anabtawi, A.; Asmar, S.; Barbinis, E.; Fleischman, D. U.; Goltz, G. L.

    2006-09-01

    The first two radio occultations of Cassini by Titan occurred on March 19 and May 20, 2006. On March 19, the ingress occultation occurred at a latitude of 31 S, and egress at 53 S. On May 20, ingress was at 33 S, and egress at 34 S. We present the temperature-pressure profiles for the atmosphere of Titan for these 4 locations.

  6. [Prevalence of occult hepatitis B virus infection and its phylogenetic features among mother-teenager pairs].

    PubMed

    Dong, Xiao-lian; Yao, Qing-qing; Wang, Xue-cai; Xu, Hai-tao; Wang, Xiao-li; Chen, Sheng-yu; Tang, Zhi-feng; Zheng, Ying-Jie

    2013-03-01

    Prevalence of occult hepatitis B virus (HBV) infection (OBI) was investigated in a paired mother-teenager population and HBV S gene variation including overt and occult HBV, was determined. A follow-up study based on an initial survey of 135 mother-teenager pairs was carried out through collection of questionnaires and blood samples HBsAg were detected by ELISA method, viral load by PCR amplification and HBV S gene by phylogenetic analysis. 102 pairs of subjects were followed-up. Blood samples from 94 mothers and 101 children were collected. OBI prevalence in mothers was 10.0% (6/60), significantly higher than 2.0% (2/101) in teenagers. Medians of viral load were 399.9 IU/ml and 247.6 IU/ml in overt and occult HBV strains, but without significant difference. 1 occult HBV strain belonged to genotype B with serotype adw while the other 7 were genotype C with serotype adr. 15 of the overt HBV strains belonged to genotype B with serotype adw and the other 8 were genotype C with serotype adr. Proportions of genotype-C strains were significantly higher in occult HBV strains than in overt HBV strains. OBI was seen in teenage-mother population.

  7. Turbulence in planetary occultations. IV - Power spectra of phase and intensity fluctuations

    NASA Technical Reports Server (NTRS)

    Haugstad, B. S.

    1979-01-01

    Power spectra of phase and intensity scintillations during occultation by turbulent planetary atmospheres are significantly affected by the inhomogeneous background upon which the turbulence is superimposed. Such coupling is particularly pronounced in the intensity, where there is also a marked difference in spectral shape between a central and grazing occultation. While the former has its structural features smoothed by coupling to the inhomogeneous background, such features are enhanced in the latter. Indeed, the latter power spectrum peaks around the characteristic frequency that is determined by the size of the free-space Fresnel zone and the ray velocity in the atmosphere; at higher frequencies strong fringes develop in the power spectrum. A confrontation between the theoretical scintillation spectra computed here and those calculated from the Mariner 5 Venus mission by Woo et al. (1974) is inconclusive, mainly because of insufficient statistical resolution. Phase and/or intensity power spectra computed from occultation data may be used to deduce characteristics of the turbulence and to distinguish turbulence from other perturbations in the refractive index. Such determinations are facilitated if observations are made at two or more frequencies (radio occultation) or in two or more colors (stellar occultation).

  8. Using the EXIST Active Shields for Earth Occultation Observations of X-Ray Sources

    NASA Technical Reports Server (NTRS)

    Wilson, Colleen A.; Fishman, Gerald; Hong, Jae-Sub; Gridlay, Jonathan; Krawczynski, Henric

    2005-01-01

    The EXIST active shields, now being planned for the main detectors of the coded aperture telescope, will have approximately 15 times the area of the BATSE detectors; and they will have a good geometry on the spacecraft for viewing both the leading and training Earth's limb for occultation observations. These occultation observations will complement the imaging observations of EXIST and can extend them to higher energies. Earth occultatio observations of the hard X-ray sky with BATSE on the Compton Gamma Ray Observatory developed and demonstrated the capabilities of large, flat, uncollimated detectors for this method. With BATSE, a catalog of 179 X-ray sources was monitored twice every spacecraft orbit for 9 years at energies above about 25 keV, resulting in 83 definite detections and 36 possible detections with 5-sigma detection sensitivities of 3.5-20 mcrab (20-430 keV) depending on the sky location. This catalog included four transients discovered with this technique and many variable objects (galactic and extragalactic). This poster will describe the Earth occultation technique, summarize the BATSE occultation observations, and compare the basic observational parameters of the occultation detector elements of BATSE and EXIST.

  9. High Resolution Asteroid Profile by Multi Chord Occultation Observations

    NASA Astrophysics Data System (ADS)

    Degenhardt, Scott

    2009-05-01

    For millennia man has observed celestial objects occulting other bodies and distant stars. We have used these celestial synchronicities to measure the properties of objects. On January 1, 1801 Italian astronomer Giusappe Piazzi discovered the first asteroid that would soon be named Ceres. To date 190,000 of these objects have been catalogued, but only a fraction of these have accurate measurements of their true size and shape. The International Occultation Timing Association (IOTA) currently facilitates the prediction and reduction of asteroidal occultations. By measuring the shadow cast on the earth by an asteroid during a stellar occultation one can directly measure the physical size, shape, and position in space of this body to accuracies orders of magnitudes better than the best ground based adaptive optics telescope and can provide verification to 3D inverted reflective lightcurve prediction models. Recent novel methods developed by IOTA involving an individual making multiple observations through unattended remote observing stations have made way for numerous chords of occultation measurement through a single body yielding high resolution profiles of asteroid bodies. Methodology of how observing stations are deployed will be demonstrated, results of some of these observations are presented as comparisons to their inverted lightcurve are shown.

  10. Impact of fecal occult blood on obscure gastrointestinal bleeding: observational study.

    PubMed

    Kobayashi, Yuka; Watabe, Hirotsugu; Yamada, Atsuo; Suzuki, Hirobumi; Hirata, Yoshihiro; Yamaji, Yutaka; Yoshida, Haruhiko; Koike, Kazuhiko

    2015-01-07

    To elucidate the association between small bowel diseases (SBDs) and positive fecal occult blood test (FOBT) in patients with obscure gastrointestinal bleeding (OGIB). Between February 2008 and August 2013, 202 patients with OGIB who performed both capsule endoscopy (CE) and FOBT were enrolled (mean age; 63.6 ± 14.0 years, 118 males, 96 previous overt bleeding, 106 with occult bleeding). All patients underwent immunochemical FOBTs twice prior to CE. Three experienced endoscopists independently reviewed CE videos. All reviews and consensus meeting were conducted without any information on FOBT results. The prevalence of SBDs was compared between patients with positive and negative FOBT. CE revealed SBDs in 72 patients (36%). FOBT was positive in 100 patients (50%) and negative in 102 (50%). The prevalence of SBDs was significantly higher in patients with positive FOBT than those with negative FOBT (46% vs 25%, P = 0.002). In particular, among patients with occult OGIB, the prevalence of SBDs was higher in positive FOBT group than negative FOBT group (45% vs 18%, P = 0.002). On the other hand, among patients with previous overt OGIB, there was no significant difference in the prevalence of SBDs between positive and negative FOBT group (47% vs 33%, P = 0.18). In disease specific analysis among patients with occult OGIB, the prevalence of ulcer and tumor were higher in positive FOBT group than negative FOBT group. In multivariate analysis, only positive FOBT was a predictive factors of SBDs in patients with OGIB (OR = 2.5, 95%CI: 1.4-4.6, P = 0.003). Furthermore, the trend was evident among patients with occult OGIB who underwent FOBT on the same day or a day before CE. The prevalence of SBDs in positive vs negative FOBT group were 54% vs 13% in patients with occult OGIB who underwent FOBT on the same day or the day before CE (P = 0.001), while there was no significant difference between positive and negative FOBT group in those who underwent FOBT two or more days before CE (43% vs 25%, P = 0.20). The present study suggests that positive FOBT may be useful for predicting SBDs in patients with occult OGIB. Positive FOBT indicates higher likelihood of ulcers or tumors in patients with occult OGIB. Undergoing CE within a day after FOBT achieved a higher diagnostic yield for patients with occult OGIB.

  11. Could texture features from preoperative CT image be used for predicting occult peritoneal carcinomatosis in patients with advanced gastric cancer?

    PubMed

    Kim, Hae Young; Kim, Young Hoon; Yun, Gabin; Chang, Won; Lee, Yoon Jin; Kim, Bohyoung

    2018-01-01

    To retrospectively investigate whether texture features obtained from preoperative CT images of advanced gastric cancer (AGC) patients could be used for the prediction of occult peritoneal carcinomatosis (PC) detected during operation. 51 AGC patients with occult PC detected during operation from January 2009 to December 2012 were included as occult PC group. For the control group, other 51 AGC patients without evidence of distant metastasis including PC, and whose clinical T and N stage could be matched to those of the patients of the occult PC group, were selected from the period of January 2011 to July 2012. Each group was divided into test (n = 41) and validation cohort (n = 10). Demographic and clinical data of these patients were acquired from the hospital database. Texture features including average, standard deviation, kurtosis, skewness, entropy, correlation, and contrast were obtained from manually drawn region of interest (ROI) over the omentum on the axial CT image showing the omentum at its largest cross sectional area. After using Fisher's exact and Wilcoxon signed-rank test for comparison of the clinical and texture features between the two groups of the test cohort, conditional logistic regression analysis was performed to determine significant independent predictor for occult PC. Using the optimal cut-off value from receiver operating characteristic (ROC) analysis for the significant variables, diagnostic sensitivity and specificity were determined in the test cohort. The cut-off value of the significant variables obtained from the test cohort was then applied to the validation cohort. Bonferroni correction was used to adjust P value for multiple comparisons. Between the two groups, there was no significant difference in the clinical features. Regarding the texture features, the occult PC group showed significantly higher average, entropy, standard deviation, and significantly lower correlation (P value < 0.004 for all). Conditional logistic regression analysis demonstrated that entropy was significant independent predictor for occult PC. When the cut-off value of entropy (> 7.141) was applied to the validation cohort, sensitivity and specificity for the prediction of occult PC were 80% and 90%, respectively. For AGC patients whose PC cannot be detected with routine imaging such as CT, texture analysis may be a useful adjunct for the prediction of occult PC.

  12. Patient factors associated with non-attendance at colonoscopy after a positive screening faecal occult blood test.

    PubMed

    Plumb, Andrew A; Ghanouni, Alex; Rainbow, Sandra; Djedovic, Natasha; Marshall, Sarah; Stein, Judith; Taylor, Stuart A; Halligan, Steve; Lyratzopoulos, Georgios; von Wagner, Christian

    2017-03-01

    Background Screening participants with abnormal faecal occult blood test results who do not attend further testing are at high risk of colorectal cancer, yet little is known about their reasons for non-attendance. Methods We conducted a medical record review of 170 patients from two English Bowel Cancer Screening Programme centres who had abnormal guaiac faecal occult blood test screening tests between November 2011 and April 2013 but did not undergo colonoscopy. Using information from patient records, we coded and categorized reasons for non-attendance. Results Of the 170 patients, 82 were eligible for review, of whom 66 had at least one recorded reason for lack of colonoscopy follow-up. Reasons fell into seven main categories: (i) other commitments, (ii) unwillingness to have the test, (iii) a feeling that the faecal occult blood test result was a false positive, (iv) another health issue taking priority, (v) failing to complete bowel preparation, (vi) practical barriers (e.g. lack of transport), and (vii) having had or planning colonoscopy elsewhere. The most common single reasons were unwillingness to have a colonoscopy and being away. Conclusions We identify a range of apparent reasons for colonoscopy non-attendance after a positive faecal occult blood test screening. Education regarding the interpretation of guaiac faecal occult blood test findings, offer of alternative confirmatory test options, and flexibility in the timing or location of subsequent testing might decrease non-attendance of diagnostic testing following positive faecal occult blood test.

  13. Ultrasound for diagnosing radiographically occult scaphoid fracture.

    PubMed

    Kwee, Robert M; Kwee, Thomas C

    2018-04-04

    To systematically review the literature on the performance of ultrasound in diagnosing radiographically occult scaphoid fracture. A systematic search was performed in the MEDLINE and Embase databases. Original studies investigating the performance of ultrasound in diagnosing radiographically occult scaphoid fracture in more than 10 patients were eligible for inclusion. Studies that included both radiographically apparent and occult scaphoid fractures (at initial radiography) were only included if independent data on radiographically occult fractures were reported. Methodological quality of the studies included was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Accuracy data were extracted. Sensitivity and specificity were pooled with a bivariate random-effects model. The inclusion criteria were met by 7 studies; total sample size comprised 314 patients. All studies, except 1, included cortical disruption of the scaphoid in their diagnostic criteria. The sensitivity and specificity of ultrasound in diagnosing radiographically occult scaphoid fracture ranged from 77.8% to 100% and from 71.4% to 100% respectively, with pooled estimates of 85.6% (95% CI: 73.9%, 92.6%) and 83.3% % (95% CI: 72.0%, 90.6%) respectively. Exclusion of two studies with a high risk of bias in any QUADAS-2 domain did not affect the pooled results. Ultrasound can diagnose radiographically occult scaphoid fracture with a fairly high degree of accuracy. Because of its relatively low costs and fairly high sensitivity, ultrasound seems more cost-effective than empiric cast immobilization and may be used when CT and MRI are not readily available.

  14. A prospective evaluation of occult disorders in obstructed defecation using the 'iceberg diagram'.

    PubMed

    Pescatori, M; Spyrou, M; Pulvirenti d'Urso, A

    2006-11-01

    Surgical treatment of constipation and obstructed defecation (OD) carries frequent recurrences, as OD is an 'iceberg syndrome' characterized by 'underwater rocks' or occult diseases which may affect the outcome of surgery. The aim of this study was to evaluate occult disorders in order to alert the clinician of these and minimize failures. One hundred consecutive constipated patients with OD symptoms, 81 female patients, median age 52 years, underwent perineal examination, proctoscopy, anorectal manometry, and anal/vaginal ultrasound. Anorectal physiology and imaging tests were also carried out when indicated, as well as psychological and urogynaecological consultation. Symptoms were graded using a modified 1-20 constipation score. Both evident (e.g. rectocele) and occult (e.g. anismus) diseases were prospectively evaluated using a novel 'iceberg diagram'. The type of treatment, whether conservative or surgical, was also recorded. Fifty-four (54%) patients had both mucosal prolapse and rectocele. All patients had at least two occult OD-related diseases, 66 patients had at least three: anxiety-depression, anismus and rectal hyposensation were the most frequent (66%, 44% and 33% respectively). The median constipation score was 11 (range 2-20), the median number of 'occult disorders' was 5 (range 2-8). Conservative treatment was carried out in most patients. Surgery was carried out in 14 (14%) patients. The novel 'iceberg diagram' allowed the adequate evaluation of OD-related occult diseases and better selection of patients for treatment. Most were managed conservatively, and only a minority were treated by surgery.

  15. A prospective evaluation of occult disorders in obstructed defecation using the 'iceberg diagram'.

    PubMed

    Pescatori, M; Spyrou, M; Pulvirenti d'Urso, A

    2007-06-01

    Surgical treatment of constipation and obstructed defecation (OD) carries frequent recurrences, as OD is an 'iceberg syndrome' characterized by 'underwater rocks' or occult diseases which may affect the outcome of surgery. The aim of this study was to evaluate occult disorders, in order to alert the clinician of these and minimize failures. One hundred consecutive constipated patients with OD symptoms, 81 women, median age 52 years, underwent perineal examination, proctoscopy, anorectal manometry and anal/vaginal ultrasound (US). Anorectal physiology and imaging tests were also carried out when indicated, as well as psychological and urogynaecological consultations. Symptoms were graded using a modified 1-20 constipation score. Both evident (e.g. rectocele) and occult (e.g. anismus) diseases were prospectively evaluated using a novel 'iceberg diagram'. The type of treatment, whether conservative or surgical, was also recorded. Fifty-four (54%) patients had both mucosal prolapse and rectocele. All patients had at least two occult OD-related diseases, 66 patients had at least three of them: anxiety-depression, anismus and rectal hyposensation were the most frequent (66%, 44% and 33%, respectively). The median constipation score was 11 (range 2-20), the median number of 'occult disorders' was 5 (range 2-8). Conservative treatment was carried out in most cases. Surgery was carried out in 14 (14%) patients. The novel 'iceberg diagram' allowed the adequate evaluation of OD-related occult diseases and better selection of patients for treatment. Most were managed conservatively, and only a minority were treated by surgery.

  16. Prevalence of occult inflammatory bowel disease in ankylosing spondylitis.

    PubMed Central

    Costello, P B; Alea, J A; Kennedy, A C; McCluskey, R T; Green, F A

    1980-01-01

    Fifty-five patients with ankylosing spondylitis and 16 control patients matched for sex and age were examined for evidence of occult inflammatory bowel disease. In all patients evaluation included history and physical examination, barium enema, sigmoidoscopy, and rectal biopsy. The results of this study suggest that there is no increased prevalence of occult inflammatory bowel disease in patients with ankylosing spondylitis. PMID:7436576

  17. The rings of Uranus

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Dunham, E.; Mink, D.

    1977-01-01

    A description is given of the observation of five brief occultations of the star SAO 158687 which occurred both before and after its occultation by Uranus on March 10, 1977. The events were observed with a three-channel occultation photometer, attached to a 91-cm telescope. The observations indicate that at least five rings encircle the planet Uranus. Possible reasons for the narrowness of the Uranus rings are discussed.

  18. Structure of scintillations in Neptune's occultation shadow

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.; Lellouch, Emmanuel; Sicardy, Bruno; Brahic, Andre; Vilas, Faith

    1988-01-01

    An exceptionally high-quality data set from a Neptune occultation is used here to derive a number of new results about the statistical properties of the fluctuations of the intensity distribution in various parts of Neptune's occultation shadow. An approximate numerical ray-tracing model which successfully accounts for many of the qualitative aspects of the observed intensity fluctuation distribution is introduced. Strong refractive scintillation is simulated by including the effects of 'turbulence' with projected atmospheric properties allowed to vary in both the direction perpendicular and parallel to the limb, and an explicit two-dimensional picture of a typical intensity distribution throughout an occulting planet's shadow is presented. The results confirm the existence of highly anisotropic turbulence.

  19. CT detection of occult pneumothorax in head trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tocino, I.M.; Miller, M.H.; Frederick, P.R.

    1984-11-01

    A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothoraxmore » during subsequent mechanical ventilation or emergency surgery under general anesthesia.« less

  20. Bone scanning in the detection of occult fractures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Batillas, J.; Vasilas, A.; Pizzi, W.F.

    1981-07-01

    The potential role of bone scanning in the early detection of occult fractures following acute trauma was investigated. Technetium 99m pyrophosphate bone scans were obtained in patients with major clinical findings and negative or equivocal roentgenograms following trauma. Bone scanning facilitated the prompt diagnosis of occult fractures in the hip, knee, wrist, ribs and costochondral junctions, sternum, vertebrae, sacrum, and coccyx. Several illustrative cases are presented. Roentgenographic confirmation occurred following a delay of days to weeks and, in some instances, the roentgenographic findings were subtle and could be easily overlooked. This study demonstrates bone scanning to be invaluable and definitivemore » in the prompt detection of occult fractures.« less

  1. Oblique Chest X-Ray: An Alternative Way to Detect Pneumothorax.

    PubMed

    Tulay, Cumhur Murat; Yaldız, Sadık; Bilge, Adnan

    2018-03-16

    To identify occult pneumothorax with oblique chest X-ray (OCXR) in clinically suspected patients. In this retrospective study, we examined 1082 adult multitrauma patients who were admitted to our emergency service between January 2016 and January 2017. Clinical findings that suggest occult pneumothorax were rib fracture, flail chest, chest pain, subcutaneous emphysema, abrasion or ecchymosis and moderate to severe hypoxia in clinical parameters. All of these patients underwent anteroposterior chest X-ray (APCXR), but no pneumothorax could be detected. Upon this, OCXR was performed using mobile X-ray equipment. Traumatic pneumothorax was observed in 421 (38.9%) of 1082 patients. We applied OCXR to 26 multitrauma patients. Occult pneumothorax was evaluated at 22 patients (2.03%) in 1082 multitrauma patients. The 22 patients who had multitrauma occult pneumothorax on OCXR were internated at intensive care unit (ICU) and follow-up was done using OCXR and APCXR. OCXR can be an alternative imaging technique to identify occult pneumothorax in some trauma patients at emergency room and also follow period at ICU.

  2. Stray light rejection in giant externally-occulted solar coronagraphs: experimental developments

    NASA Astrophysics Data System (ADS)

    Venet, M.; Bazin, C.; Koutchmy, S.; Lamy, P.

    2017-11-01

    The advent of giant, formation-flight, externally-occulted solar coronagraphs such as ASPIICS (Association de Satellites Pour l'Imagerie et l'Interférométrie de la Couronne Solaire [1,2,3,4]) selected by the European Space Agency (ESA) for its third PROBA (Project for On-Board Autonomy) mission of formation flying demonstration (presently in phase B) and Hi-RISE proposed in the framework of ESA Cosmic Vision program, presents formidable challenges for the study and calibration of instrumental stray light. With distances between the external occulter (EO) and the optical pupil (OP) exceeding hundred meters and occulter sizes larger than a meter, it becomes impossible to perform tests at the real scale. The requirement to limit the over-occultation to less than 1.05 Rsun, orders of magnitude to what has been achieved so far in past coronagraphs, further adds to the challenge. We are approaching the problem experimentally using reduced scale simulators and present below a progress report of our work.

  3. Occult hepatitis B virus infection in HIV positive patients at a tertiary healthcare unit in eastern India

    PubMed Central

    Saha, Debraj; Pal, Ananya; Sarkar, Neelakshi; Das, Dipanwita; Blackard, Jason T.; Guha, Subhasish Kamal; Saha, Bibhuti

    2017-01-01

    Occult HBV infection (OBI), defined by the presence of HBV DNA in absence of hepatitis B surface antigen (HBsAg), is a significant concern in the HIV-infected population. Of 441 HIV+/HBsAg- patients analyzed, the overall prevalence of OBI was 6.3% (28/441). OBI was identified in 21 anti-HBc positives (17.8%), as well as among those who lacked any HBV-specific serological markers (2.2%). Comparison with HIV/HBV co-infection revealed that the levels of CD4, ALT, and HBV DNA were significantly lower during occult infection. Discrete differences were also observed with respect to quasispecies divergence. Additionally, subgenotype D1 was most frequent in occult infection, while D2 was widespread during chronic infection. The majority (~90%) of occult D1 sequences had the sQ129R mutation in the surface gene. This study highlights several distinct features of OBI in India and underscores the need for additional HBV DNA screening in HIV-positive individuals. PMID:28591184

  4. Occult hepatitis B virus infection in HIV positive patients at a tertiary healthcare unit in eastern India.

    PubMed

    Saha, Debraj; Pal, Ananya; Sarkar, Neelakshi; Das, Dipanwita; Blackard, Jason T; Guha, Subhasish Kamal; Saha, Bibhuti; Chakravarty, Runu

    2017-01-01

    Occult HBV infection (OBI), defined by the presence of HBV DNA in absence of hepatitis B surface antigen (HBsAg), is a significant concern in the HIV-infected population. Of 441 HIV+/HBsAg- patients analyzed, the overall prevalence of OBI was 6.3% (28/441). OBI was identified in 21 anti-HBc positives (17.8%), as well as among those who lacked any HBV-specific serological markers (2.2%). Comparison with HIV/HBV co-infection revealed that the levels of CD4, ALT, and HBV DNA were significantly lower during occult infection. Discrete differences were also observed with respect to quasispecies divergence. Additionally, subgenotype D1 was most frequent in occult infection, while D2 was widespread during chronic infection. The majority (~90%) of occult D1 sequences had the sQ129R mutation in the surface gene. This study highlights several distinct features of OBI in India and underscores the need for additional HBV DNA screening in HIV-positive individuals.

  5. An atmosphere on Ganymede from its occultation of SAO 186800 on 7 June 1972.

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Bhattacharyya, J. C.; Smith, B. A.; Johnson, T. V.; Hidayat, B.; Smith, S. A.; Taylor, G. E.; O'Leary, B.; Brinkmann, R. T.

    1973-01-01

    The observational data obtained during the occultation are of sufficient quality to determine the occultation radius and to support the inference that Ganymede does possess at least a modest atmosphere. Assuming a circular cross section, the diameter of Ganymede was found to be 5271 km. Effects of the atmosphere on the accuracy of the value obtained for the Ganymede diameter are discussed.

  6. Validation of Biomarkers for Prostate Cancer Prognosis

    DTIC Science & Technology

    2015-11-01

    and actually have occult high-risk features or are destined to progress to high-risk disease. Therefore a critical need in localized prostate...cancer is the development of biomarkers that predict occult or incipient aggressive disease in the low-risk population. 15. SUBJECT TERMS- Nothing...causing death. However, it is well known that a significant fraction of low risk cases are misclassified and actually have occult high-risk features or

  7. The third in mind.

    PubMed

    Widlöcher, Daniel

    2004-01-01

    Various aspects of the occult as they relate to psychoanalysis are discussed in this article. Drawing on both Freud's writings and Granoff and Rey's (1983) work on the occult in Freudian thought, the author considers the concept of co-thinking and its manifestations in clinical work. The psychoanalytic third is viewed in the context of the occult element known as thought transference, or thought transmission, and is also considered as it bears on psychoanalytic supervision.

  8. Prevalence of occult hepatitis B virus infection in haemodialysis patients from central Greece

    PubMed Central

    Mina, Paraskevi; Georgiadou, Sarah P; Rizos, Christos; Dalekos, George N; Rigopoulou, Eirini I

    2010-01-01

    AIM: To assess the hepatitis B virus (HBV)-DNA and the prevalence of occult HBV infection in end-stage renal failure (ESRF) patients from Central Greece. METHODS: Sera from 366 ESRF patients attending five out of six dialysis units from Central Greece were investigated for HBV-DNA by real-time polymerase chain reaction. Only serum samples with repeatedly detectable HBV-DNA were considered positive. IgG antibodies to hepatitis C virus (anti-HCV) were tested by a third generation enzyme linked immunosorbent assay (ELISA), while IgG antibodies to hepatitis E virus (anti-HEV) were tested by two commercially available ELISAs. RESULTS: HBV-DNA was detected in 15/366 patients (4.1%) and HBsAg in 20/366 (5.5%). The prevalence of occult HBV infection was 0.9% (3/346 HBsAg-negative patients). Occult HBV was not associated with a specific marker of HBV infection or anti-HCV or anti-HEV reactivity. There was no significant difference in HBV-DNA titres, demographic and biochemical features, between patients with occult HBV infection and those with HBsAg-positive chronic HBV infection. CONCLUSION: In central Greece, 4% of ESRF patients had detectable HBV-DNA, though in this setting, the prevalence of occult HBV seems to be very low (0.9%). PMID:20066742

  9. [Occultism, parapsychology and the esoteric from the perspective of psychopathology].

    PubMed

    Scharfetter, C

    1998-10-01

    The concepts and main themes of occultism, parapsychology and esoterics are set in comparison to religion, spirituality, mysticism. The cultural relativity of these concepts is emphasised. Occultism means dealing with phenomena, processes, and/or powers which are not accessible to "normal perception". The manipulation of such powers is effected via (white, black, grey) magic. Parapsychology, in its popular sense, deals with occult phenomena, whereas scientific parapsychology investigates them empirically. Esoterics is a complex of beliefs within a hermetic tradition about occult processes and about desting after death. Transpersonal psychology deals with these issues while calling them "spiritual". Effects of paranormal experiences and actions on the side of the actor as well as the adept are discussed: personality types, interpersonal effects, crises and psychoses (mediumistic psychoses). The concept of dissociation of subpersonalities (subselves) appears to be a viable perspective to explain these phenomena. In mediumistic psychoses, the splitting of non-ego parts of the psyche leads to a manifestation of schizophrenic symptoms. Dangers for mental health are an ego inflation by self-attribution of "superhuman" power. A personality disposition for parapsychological perception and/or action may be seen in schizotypia and similar near-psychotic "personalities up the border". Adepts of occultism may present with a "false self" in the sense of Winnicott.

  10. Role of staging laparoscopy in the management of Pancreatic Duct Carcinoma (PDAC): Single-center experience from a tertiary hospital in Brazil.

    PubMed

    de Jesus, Victor Hugo Fonseca; da Costa Junior, Wilson Luiz; de Miranda Marques, Tomás Mansur Duarte; Diniz, Alessandro Landskron; de Castro Ribeiro, Héber Salvador; de Godoy, André Luis; de Farias, Igor Correia; Coimbra, Felipe José Fernandez

    2018-04-01

    Proper staging is critical to the management of pancreatic ductal carcinoma (PDAC). Laparoscopy has been used to stage patients without gross metastatic disease with variable success. We aimed to identify the frequency of patients diagnosed by laparoscopy with occult metastatic disease. Also, we looked for variables related to a higher chance of occult metastasis. Patients with PDAC submitted to staging laparoscopy either immediately before pancreatectomy or as a separate procedure between January 2010 and December 2016 were included. None presented gross metastatic disease at initial staging. We used logistic regression to search for variables associated with metastatic disease. The study population consisted of 63 patients. Among all patients, nine (16.7%) had occult metastases at laparoscopy. Unresectable tumor (Odds ratio = 18.0, P = 0.03), increasing tumor size (Odds ratio = 1.36, P = 0.01), and abdominal pain (Odds ratio = 5.6, P = 0.04) significantly predicted the risk of occult metastases in univariate analysis. In multivariate analysis, only tumor size predicted the risk of occult metastases. Laparoscopy remains a valuable tool in PDAC staging. Patients with either large or unresectable tumors, or presenting with abdominal pain present the highest risk for occult intra-abdominal metastases. © 2018 Wiley Periodicals, Inc.

  11. Outcome of Concurrent Occult Hemothorax and Pneumothorax in Trauma Patients Who Required Assisted Ventilation

    PubMed Central

    Mahmood, Ismail; Tawfeek, Zainab; El-Menyar, Ayman; Zarour, Ahmad; Afifi, Ibrahim; Kumar, Suresh; Latifi, Rifat; Al-Thani, Hassan

    2015-01-01

    Background. The management and outcomes of occult hemopneumothorax in blunt trauma patients who required mechanical ventilation are not well studied. We aimed to study patients with occult hemopneumothorax on mechanical ventilation who could be carefully managed without tube thoracostomy. Methods. Chest trauma patients with occult hemopneumothorax who were on mechanical ventilation were prospectively evaluated. The presence of hemopneumothorax was confirmed by CT scanning. Hospital length of stay, complications, and outcome were recorded. Results. A total of 56 chest trauma patients with occult hemopneumothorax who were on ventilatory support were included with a mean age of 36 ± 13 years. Hemopneumothorax was managed conservatively in 72% cases and 28% underwent tube thoracostomy as indicated. 29% of patients developed pneumonia, 16% had Acute Respiratory Distress Syndrome (ARDS), and 7% died. Thickness of hemothorax, duration of mechanical ventilation, and development of ARDS were significantly associated with tube thoracostomy in comparison to no-chest tube group. Conclusions. The majority of occult hemopneumothorax can be carefully managed without tube thoracostomy in patients who required positive pressure ventilation. Tube thoracotomy could be restricted to those who had evidence of increase in the size of the hemothorax or pneumothorax on follow-up chest radiographs or developed respiratory compromise. PMID:25785199

  12. Prevalence of occult hepatitis B virus infection in haemodialysis patients from central Greece.

    PubMed

    Mina, Paraskevi; Georgiadou, Sarah P; Rizos, Christos; Dalekos, George N; Rigopoulou, Eirini I

    2010-01-14

    To assess the hepatitis B virus (HBV)-DNA and the prevalence of occult HBV infection in end-stage renal failure (ESRF) patients from Central Greece. Sera from 366 ESRF patients attending five out of six dialysis units from Central Greece were investigated for HBV-DNA by real-time polymerase chain reaction. Only serum samples with repeatedly detectable HBV-DNA were considered positive. IgG antibodies to hepatitis C virus (anti-HCV) were tested by a third generation enzyme linked immunosorbent assay (ELISA), while IgG antibodies to hepatitis E virus (anti-HEV) were tested by two commercially available ELISAs. HBV-DNA was detected in 15/366 patients (4.1%) and HBsAg in 20/366 (5.5%). The prevalence of occult HBV infection was 0.9% (3/346 HBsAg-negative patients). Occult HBV was not associated with a specific marker of HBV infection or anti-HCV or anti-HEV reactivity. There was no significant difference in HBV-DNA titres, demographic and biochemical features, between patients with occult HBV infection and those with HBsAg-positive chronic HBV infection. In central Greece, 4% of ESRF patients had detectable HBV-DNA, though in this setting, the prevalence of occult HBV seems to be very low (0.9%).

  13. [Surgical Diagnosis and Treatment of Primary Hyperthyroidism Complicated with Occult Thyroid Carcinoma].

    PubMed

    Wu, Xin; Yu, Jian-chun; Kang, Wei-ming; Ma, Zhi-qiang; Ye, Xin

    2015-08-01

    To evaluate the surgical diagnosis and treatment of primary hyperthyroidism complicated with occult thyroid carcinoma. Data of 51 cases of primary hyperthyroidism complicated with occult thyroid carcinoma admitted during January 2004 to November 2014 were analyzed retrospectively. The incidence of occult thyroid carcinoma was 5.03% in hyperthyroidism,and 47 cases (92.16%) were female. The preoperative diagnosis of all these 51 cases was primary hyperthyroidism and 11 cases were diagnosed thyroid carcinoma at the same time;25 cases were diagnosed thyroid carcinoma by frozen section and the remaining 26 cases were diagnosed by postoperative pathology. Finally,26 cases underwent subtotal thyroidectomy,4 cases underwent total thyroidectomy, and 21 cases underwent total thyroidectomy with lymphadenectomy. The tumor size ranged from 0.1 to 1.0 cm [mean:(0.63 ± 0.35) cm]. The lesions were less than or equal to 0.5 cm in 28 cases (54.9%). The follow-up lasted from 1 to 121 months [mean:(28.6 ± 22.7)months] in 43 patients,and all of them survived. Primary hyperthyroidism complicated with occult thyroid carcinoma is commonly found in female patients. Preoperative diagnosis is difficult. Ultrasound is the major examining method. Frozen section can increase the detection rate. The postoperative prognosis of hyperthyroidism complicated with occult thyroid carcinoma is satisfactory.

  14. Occult tinea pedis in an Israeli population and predisposing factors for the acquisition of the disease.

    PubMed

    Sakka, Nicole; Shemer, Avner; Barzilai, Aviv; Farhi, Renata; Daniel, Ralph

    2015-02-01

    Tinea pedis is a commonly encountered dermatophytic infection with a clinical prevalence of 15-25%. Limited studies have evaluated the prevalence of occult tinea pedis. The aims of this study were to evaluate the prevalence of occult tinea pedis in asymptomatic subjects with feet that appeared healthy and to identify possible related risk factors. A prospective study of 221 asymptomatic subjects with apparently normal feet was conducted. All subjects completed a questionnaire covering anamnestic details (personal and family histories of tinea pedis, preferred footwear) and were examined for foot odor and the clinical presence of tinea pedis and onychomycosis. Samples were taken from the foot for direct microscopic examination and culture. Among the 221 patients, 31 (14.0%) were positive for occult tinea pedis. Positive cultures from both the anterior and posterior aspects of the foot were obtained in 22 patients. The most common pathogen isolated was Trichophyton rubrum. Strong correlations emerged between occult tinea pedis and characteristics such as male gender, foot odor, previous personal and family histories of tinea pedis, and clinical and mycological evidence of onychomycosis. No significant associations were found between occult tinea pedis and age or preferred footwear. The prevalence of occult tinea pedis is similar to that of clinical tinea pedis. This may imply that patients with subclinical infection carry a risk for transmitting disease similar to that of clinical carriers. This is of great importance in the prevention and management of the disease as high-risk asymptomatic carriers can be identified. © 2014 The International Society of Dermatology.

  15. Outcomes of asymptomatic anastomotic leaks found on routine postoperative water-soluble enema following anterior resection for cancer.

    PubMed

    Killeen, S; Souroullas, P; Ho Tin, H; Hunter, I A; O'Grady, H; Gunn, J; Hartley, J E

    2013-11-01

    The incidence and consequence of an anastomotic leak associated with low anterior resection for cancer mandates covering stoma in most cases. A water-soluble enema is often performed to assess anastomotic integrity prior to stoma reversal. The functional outcome following reversal in patients with occult radiologically detected leaks is poorly defined. The goal of the present study was to determine the functional outcome in patients with a radiologically detected anastomotic leak who subsequently underwent stoma reversal. This case control study used patients with and without radiologically detected occult anastomotic leak having undergone reversal of covering stomata. The study group was matched with controls for age, gender, procedure, tumor stage, and adjuvant/neoadjuvant therapy. Validated fecal incontinence quality of life (FIQL), Cleveland Clinic Fecal Incontinence Score (CCFIS), and the Memorial Sloan-Kettering Cancer Center (MSKCC) Bowel Function Index (BFI) were used. Patient satisfaction, medication use, and ancillary procedures prior to closure were also recorded. Thirteen patients with radiologically detected occult anastomotic leaks and 13 matched controls were identified from a prospectively maintained database. The FIQL, CCFIS, and MSKCC BFI scores were significantly reduced in those with occult leaks. The mean number of radiological and surgical interventions was significantly greater in the patients with occult leaks. Antidiarrheal and bulking agent use, as well as patient satisfaction, were the same for both groups. Only one patient in the occult leak group would not undergo stoma reversal again. Reversal of a defunctioning ileostomy in the presence of an occult radiological leak can be associated with poorer functional outcomes, but patient satisfaction is undiminished.

  16. Functional analysis of 'a' determinant mutations associated with occult HBV in HIV-positive South Africans.

    PubMed

    Powell, Eleanor A; Boyce, Ceejay L; Gededzha, Maemu P; Selabe, Selokela G; Mphahlele, M Jeffrey; Blackard, Jason T

    2016-07-01

    Occult hepatitis B is defined by the presence of hepatitis B virus (HBV) DNA in the absence of hepatitis B surface antigen (HBsAg). Occult HBV is associated with the development of hepatocellular carcinoma, reactivation during immune suppression, and virus transmission. Viral mutations contribute significantly to the occult HBV phenotype. Mutations in the 'a' determinant of HBsAg are of particular interest, as these mutations are associated with immune escape, vaccine escape and diagnostic failure. We examined the effects of selected occult HBV-associated mutations identified in a population of HIV-positive South Africans on HBsAg production in vitro. Mutations were inserted into two different chronic HBV backbones and transfected into a hepatocyte-derived cell line. HBsAg levels were quantified by enzyme-linked immunosorbent assay (ELISA), while the detectability of mutant HBsAg was determined using an HA-tagged HBsAg expression system. Of the seven mutations analysed, four (S132P, C138Y, N146D and C147Y) resulted in decreased HBsAg expression in one viral background but not in the second viral background. One mutation (N146D) led to a decrease in HBsAg detected as compared to HA-tag, indicating that this mutation compromises the ability of the ELISA to detect HBsAg. The contribution of occult-associated mutations to the HBsAg-negative phenotype of occult HBV cannot be determined adequately by testing the effect of the mutation in a single viral background, and rigorous analysis of these mutations is required.

  17. A stellar occultation by (486958) 2014 MU69: results from the 2017 July 17 portable telescope campaign

    NASA Astrophysics Data System (ADS)

    Zangari, Amanda Marie; Buie, Marc W.; Stern, S. Alan; Terrell, Dirk; Porter, Simon Bernard; Verbiscer, Anne J.; Soto, Alejandro; Tamblyn, Peter; Benecchi, Susan; Parker, Alex; Wasserman, Lawrence H.; Young, Eliot F.; Skrutskie, Michael F.; New Horizons MU69 Occultation Observing Team

    2017-10-01

    On 2017 July 17, (486958) 2014 MU69 passed in front of a star as seen from the area north of Comodoro Rivadavia, in Chubut Province, Argentina. Despite challenging wind conditions, twenty two portable telescopes recorded data of the g'= 12.60 mag star in a 45-minute block centered on the predicted midtime of roughly 03:50 UT. Each telescope was spaced approximately 4 km apart in a “picket fence” pattern to target an object as small as 10 km. The picket fence spanned roughly 100 km. Five telescopes observed a solid body occultation.Occultation data provide a unique one-dimensional probe of the 2014 MU69 system that is impossible to achieve from direct imaging. These data will allow for fits of the size and shape of 2014 MU69, and from its derived size, the albedo . The occultation data will also aid in navigation of NASA’s New Horizons spacecraft toward its January 1, 2019 encounter with 2014 MU69.We will detail the July 17 occultation campaign and present analyses of the light curves from each portable station, including occultation timing and constraints on dust and and other objects in the system derived from the occultation baseline data.This work would not have been possible without the financial support of the New Horizons mission and NASA, astrometric support of the Gaia mission and HST, and logistical support from Argentina, CONAE and specifically Comodoro Rivadavia as well as assistance from the US Embassy in Buenos Aires.

  18. Occult Hepatitis B Virus Infection in Anti-HBs-Positive Infants Born to HBsAg-Positive Mothers in China

    PubMed Central

    Xu, Dezhong; Wang, Bo; Zhang, Lei; Li, Duan; Xiao, Dan; Li, Fan; Zhang, Jingxia; Yan, Yongping

    2013-01-01

    Objective To investigate the prevalence of occult HBV infection (OBI) among children and to characterize virology of occult HBV, we conducted an epidemiological survey. Methods 186 HB-vaccinated infants born to HBsAg-positive mothers were included in the study. Serological tests for HBV markers were performed using commercial ELISA kits. Real-time quantitative PCR and nested PCR were used to detect HBV DNA. PCR products of the C and pre-S/S regions were sequenced and analyzed. Results 1.61% (3/186) infants were HBsAg positive, and 4.92% (9/183) infants were considered as occult infection. The viral load of mothers was associated with occult infection (P = 0.020). Incomplete three-dose injections of HB vaccine was associated with HBV infection (P = 0.022). Six OBI infants were positive for anti-HBs, but their titers were not greater than 100 mIU/mL. Seven isolated HBV pre-S/S sequences were obtained from nine OBI infants. Three of the sequences were genotype C, and four of the sequences were genotype C/D. Escape mutation S143L was found in the four sequences of genotype C/D. All seven sequences lacked G145R and other escape mutation in S region. Conclusions Occult HBV infection was detected in anti-HBs positive infants born to HBsAg-positive mothers in China. Occult infection was associated with absent anti-HBs or with low anti-HBs level, high maternal viral loads and escape mutations in the S gene. PMID:23951004

  19. Identification of occult tumors by whole-specimen mapping in solitary papillary thyroid carcinoma.

    PubMed

    Park, Seog Yun; Jung, Yuh-S; Ryu, Chang Hwan; Lee, Chang Yoon; Lee, You Jin; Lee, Eun Kyung; Kim, Seok-Ki; Kim, Tae Sung; Kim, Tae Hyun; Jang, Jeyun; Park, Daeyoon; Dong, Seung Myung; Kang, Jae-Goo; Lee, Jin Soo; Ryu, Junsun

    2015-08-01

    We undertook this study to estimate an accurate incidence and spread patterns of occult papillary thyroid carcinoma (PTC) in patients with a preoperative diagnosis of solitary PTC by using whole-specimen mapping of all specimens after a total thyroidectomy. Enrolled prospectively in this whole-thyroid mapping study are 82 consecutive patients who underwent a total thyroidectomy under a preoperative diagnosis of solitary PTC. All thyroidectomy specimens were serially sectioned in 2 mm thickness and whole-thyroid mapping was carried out for additional foci of occult PTC. The frequencies of occult lesions detected in the whole and contralateral lobe were determined, and clinicopathologic factors associated with multifocality were assessed. Whole-thyroid mapping revealed 66 occult PTC lesions missed by preoperative ultrasound in 37 (45.1%) of the 82 patients. The great majority (92.5%) of the occult PTC was smaller than 3 mm in size and 25 patients (30.5%) had contralateral lesions. We found that the male sex was an independent predictor of multifocality (odds ratio (OR), 3.00; 95% CI, 1.11-8.14), adjusting for preoperative findings. Analysis with pathologic parameters showed that the male sex (OR, 5.03; 95% CI, 1.68-15.08) and extrathyroidal extensions (OR, 3.03; 95% CI, 1.03-8.95) were associated with multifocal PTC. However, none of the clinicopathologic factors evaluated predicted contralateral PTC. Our study demonstrates the diagnostic limitations of ultrasound for the detection of multifocal PTC and the need to consider the possibility of occult lesions in the management of solitary PTC, especially in male patients. © 2015 Society for Endocrinology.

  20. Functional analysis of ‘a’ determinant mutations associated with occult HBV in HIV-positive South Africans

    PubMed Central

    Powell, Eleanor A.; Boyce, Ceejay L.; Gededzha, Maemu P.; Selabe, Selokela G.; Mphahlele, M. Jeffrey

    2016-01-01

    Occult hepatitis B is defined by the presence of hepatitis B virus (HBV) DNA in the absence of hepatitis B surface antigen (HBsAg). Occult HBV is associated with the development of hepatocellular carcinoma, reactivation during immune suppression, and virus transmission. Viral mutations contribute significantly to the occult HBV phenotype. Mutations in the ‘a’ determinant of HBsAg are of particular interest, as these mutations are associated with immune escape, vaccine escape and diagnostic failure. We examined the effects of selected occult HBV-associated mutations identified in a population of HIV-positive South Africans on HBsAg production in vitro. Mutations were inserted into two different chronic HBV backbones and transfected into a hepatocyte-derived cell line. HBsAg levels were quantified by enzyme-linked immunosorbent assay (ELISA), while the detectability of mutant HBsAg was determined using an HA-tagged HBsAg expression system. Of the seven mutations analysed, four (S132P, C138Y, N146D and C147Y) resulted in decreased HBsAg expression in one viral background but not in the second viral background. One mutation (N146D) led to a decrease in HBsAg detected as compared to HA-tag, indicating that this mutation compromises the ability of the ELISA to detect HBsAg. The contribution of occult-associated mutations to the HBsAg-negative phenotype of occult HBV cannot be determined adequately by testing the effect of the mutation in a single viral background, and rigorous analysis of these mutations is required. PMID:27031988

  1. Effect of diet on results obtained by use of two commercial test kits for detection of occult blood in feces of dogs.

    PubMed

    Cook, A K; Gilson, S D; Fischer, W D; Kass, P H

    1992-10-01

    To evaluate the effect of diet on results obtained by use of 2 commercial test kits for detection of occult blood in feces, 5 dogs were fed 7 diets in randomized sequence. Dry and canned diets with various principal ingredients were evaluated. Each diet was offered twice over a 24-hour period, followed by a 36-hour nonfeeding period. Fecal specimens were collected twice daily, and tests for occult blood were performed within 12 hours. The dietary origin of fecal specimens was confirmed by use of colored markers fed with each diet, and was correlated with estimates of gastrointestinal tract transit time. A modified guaiac paper test and an o-tolidine tablet test were performed on each specimen. Of 59 specimens, 4 were positive for occult blood, using the o-tolidine tablet test. Three positive results were associated with a mutton-based canned diet, and 1 positive result was associated with a canned beef-based diet. Of 59 specimens, 11 were positive for occult blood, using the modified guaiac paper test. Four positive results were associated with the mutton diet, and 3 positive results were associated with the beef diet. Of the remaining 5 diets, 4 caused 1 positive reaction. Results were inconsistent with the null hypothesis that the distribution of positive occult blood test results is not affected by diet (P < 0.025), and indicate that diet can affect the specificity of peroxidase-based tests for detection of occult blood in canine feces. Diet modification prior to testing is recommended.

  2. The stellar occultation by the dwarf planet Haumea

    NASA Astrophysics Data System (ADS)

    Santos-Sanz, Pablo; Ortiz, Jose Luis; Sicardy, Bruno; Rossi, Gustavo; Berard, Diane; Morales, Nicolas; Duffard, Rene; Braga-Ribas, Felipe; Hopp, Ulrich; Ries, Christoph; Nascimbeni, Valerio; Marzari, Francesco; Granata, Valentina; Pál, András; Kiss, Csaba; Pribulla, Theodor; Milan Komzík, Richard; Hornoch, Kamil; Pravec, Petr; Bacci, Paolo; Maestripieri, Martina; Nerli, Luca; Mazzei, Leonardo; Bachini, Mauro; Martinelli, Fabio; Succi, Giacomo; Ciabattari, Fabrizio; Mikuz, Herman; Carbognani, Albino; Gaehrken, Bernd; Mottola, Stefano; Hellmich, Stephan; Rommel, Flavia; Fernández-Valenzuela, Estela; Campo Bagatin, Adriano; Haumea occultation international Collaboration: https://cloud.iaa.csic.es/public.php?service=files&t=d9276f8ab1a316cef13bee28bef75add

    2017-10-01

    The dwarf planet Haumea is a very peculiar Trans-Neptunian Object (TNO) with unique and exotic characteristics. It is currently classified as one of the five dwarf planets of the solar system, and it is the only one for which size, shape, albedo, density and other basic properties were not accurately known. To solve that we predicted an occultation of the star GaiaDR1 1233009038221203584 by Haumea and organized observations within the expected shadow path. Medium/large telescopes were needed to record the occultation with enough signal to noise ratio because the occulted star is of similar brightness as Haumea (R~17.7 mag). We will report results derived from this successful stellar occultation by Haumea on 2017 January 21st. The occultation was positive from 12 telescopes at 10 observing stations in Europe: the Asiago Observatory 1.8m telescope (Italy), the Mount Agliale Observatory 0.5m telescope (Italy), the Lajatico Astronomical Centre 0.5m telescope (Italy), the S.Marcello Pistoiese Observatory 0.6m telescope (Italy), the Crni Vrh Observatory 0.6m telescope (Slovenia), the Ondrejov Observatory 0.65m telescope (Czech Republic), the Bavarian Public Observatory 0.81m telescope (Germany), the Konkoly Observatory 1m and 0.6m telescopes (Hungary), the Skalnate Pleso Observatory 1.3m telescope (Slovakia), and the Wendelstein Observatory 2m and 0.4m telescopes (Germany). This is the occultation by a TNO with the largest number of chords ever recorded.Part of this work has received funding from the European Union’s Horizon 2020 Research and Innovation Programme under Grant Agreement No. 687378.

  3. Air-cooling mathematical analysis as inferred from the air-temperature observation during the 1st total occultation of the Sun of the 21st century at Lusaka, Zambia

    NASA Astrophysics Data System (ADS)

    Peñaloza-Murillo, Marcos A.; Pasachoff, Jay M.

    2015-04-01

    We analyze mathematically air temperature measurements made near the ground by the Williams College expedition to observe the first total occultation of the Sun [TOS (commonly known as a total solar eclipse)] of the 21st century in Lusaka, Zambia, in the afternoon of June 21, 2001. To do so, we have revisited some earlier and contemporary methods to test their usefulness for this analysis. Two of these methods, based on a radiative scheme for solar radiation modeling and that has been originally applied to a morning occultation, have successfully been combined to obtain the delay function for an afternoon occultation, via derivation of the so-called instantaneous temperature profiles. For this purpose, we have followed the suggestion given by the third of these previously applied methods to calculate this function, although by itself it failed to do so at least for this occultation. The analysis has taken into account the limb-darkening, occultation and obscuration functions. The delay function obtained describes quite fairly the lag between the solar radiation variation and the delayed air temperature measured. Also, in this investigation, a statistical study has been carried out to get information on the convection activity produced during this event. For that purpose, the fluctuations generated by turbulence has been studied by analyzing variance and residuals. The results, indicating an irreversible steady decrease of this activity, are consistent with those published by other studies. Finally, the air temperature drop due to this event is well estimated by applying the empirical scheme given by the fourth of the previously applied methods, based on the daily temperature amplitude and the standardized middle time of the occultation. It is demonstrated then that by using a simple set of air temperature measurements obtained during solar occultations, along with some supplementary data, a simple mathematical analysis can be achieved by applying of the four methods reviewed here.

  4. Estimation and evaluation of COSMIC radio occultation excess phase using undifferenced measurements

    NASA Astrophysics Data System (ADS)

    Xia, Pengfei; Ye, Shirong; Jiang, Kecai; Chen, Dezhong

    2017-05-01

    In the GPS radio occultation technique, the atmospheric excess phase (AEP) can be used to derive the refractivity, which is an important quantity in numerical weather prediction. The AEP is conventionally estimated based on GPS double-difference or single-difference techniques. These two techniques, however, rely on the reference data in the data processing, increasing the complexity of computation. In this study, an undifferenced (ND) processing strategy is proposed to estimate the AEP. To begin with, we use PANDA (Positioning and Navigation Data Analyst) software to perform the precise orbit determination (POD) for the purpose of acquiring the position and velocity of the mass centre of the COSMIC (The Constellation Observing System for Meteorology, Ionosphere and Climate) satellites and the corresponding receiver clock offset. The bending angles, refractivity and dry temperature profiles are derived from the estimated AEP using Radio Occultation Processing Package (ROPP) software. The ND method is validated by the COSMIC products in typical rising and setting occultation events. Results indicate that rms (root mean square) errors of relative refractivity differences between undifferenced and atmospheric profiles (atmPrf) provided by UCAR/CDAAC (University Corporation for Atmospheric Research/COSMIC Data Analysis and Archive Centre) are better than 4 and 3 % in rising and setting occultation events respectively. In addition, we also compare the relative refractivity bias between ND-derived methods and atmPrf profiles of globally distributed 200 COSMIC occultation events on 12 December 2013. The statistical results indicate that the average rms relative refractivity deviation between ND-derived and COSMIC profiles is better than 2 % in the rising occultation event and better than 1.7 % in the setting occultation event. Moreover, the observed COSMIC refractivity profiles from ND processing strategy are further validated using European Centre for Medium-Range Weather Forecasts (ECMWF) analysis data, and the results indicate that the undifferenced method reduces the noise level on the excess phase paths in the lower troposphere compared to the single-difference processing strategy.

  5. Impact of D-Dimer for Prediction of Incident Occult Cancer in Patients with Unprovoked Venous Thromboembolism

    PubMed Central

    Han, Donghee; ó Hartaigh, Bríain; Lee, Ji Hyun; Cho, In-Jeong; Shim, Chi Young; Chang, Hyuk-Jae; Hong, Geu-Ru; Ha, Jong-Won; Chung, Namsik

    2016-01-01

    Background Unprovoked venous thromboembolism (VTE) is related to a higher incidence of occult cancer. D-dimer is clinically used for screening VTE, and has often been shown to be present in patients with malignancy. We explored the predictive value of D-dimer for detecting occult cancer in patients with unprovoked VTE. Methods We retrospectively examined data from 824 patients diagnosed with deep vein thrombosis or pulmonary thromboembolism. Of these, 169 (20.5%) patients diagnosed with unprovoked VTE were selected to participate in this study. D-dimer was categorized into three groups as: <2,000, 2,000–4,000, and >4,000 ng/ml. Cox regression analysis was employed to estimate the odds of occult cancer and metastatic state of cancer according to D-dimer categories. Results During a median 5.3 (interquartile range: 3.4–6.7) years of follow-up, 24 (14%) patients with unprovoked VTE were diagnosed with cancer. Of these patients, 16 (67%) were identified as having been diagnosed with metastatic cancer. Log transformed D-dimer levels were significantly higher in those with occult cancer as compared with patients without diagnosis of occult cancer (3.5±0.5 vs. 3.2±0.5, P-value = 0.009, respectively). D-dimer levels >4,000 ng/ml was independently associated with occult cancer (HR: 4.12, 95% CI: 1.54–11.04, P-value = 0.005) when compared with D-dimer levels <2,000 ng/ml, even after adjusting for age, gender, and type of VTE (e.g., deep vein thrombosis or pulmonary thromboembolism). D-dimer levels >4000 ng/ml were also associated with a higher likelihood of metastatic cancer (HR: 9.55, 95% CI: 2.46–37.17, P-value <0.001). Conclusion Elevated D-dimer concentrations >4000 ng/ml are independently associated with the likelihood of occult cancer among patients with unprovoked VTE. PMID:27073982

  6. Impact of D-Dimer for Prediction of Incident Occult Cancer in Patients with Unprovoked Venous Thromboembolism.

    PubMed

    Han, Donghee; ó Hartaigh, Bríain; Lee, Ji Hyun; Cho, In-Jeong; Shim, Chi Young; Chang, Hyuk-Jae; Hong, Geu-Ru; Ha, Jong-Won; Chung, Namsik

    2016-01-01

    Unprovoked venous thromboembolism (VTE) is related to a higher incidence of occult cancer. D-dimer is clinically used for screening VTE, and has often been shown to be present in patients with malignancy. We explored the predictive value of D-dimer for detecting occult cancer in patients with unprovoked VTE. We retrospectively examined data from 824 patients diagnosed with deep vein thrombosis or pulmonary thromboembolism. Of these, 169 (20.5%) patients diagnosed with unprovoked VTE were selected to participate in this study. D-dimer was categorized into three groups as: <2,000, 2,000-4,000, and >4,000 ng/ml. Cox regression analysis was employed to estimate the odds of occult cancer and metastatic state of cancer according to D-dimer categories. During a median 5.3 (interquartile range: 3.4-6.7) years of follow-up, 24 (14%) patients with unprovoked VTE were diagnosed with cancer. Of these patients, 16 (67%) were identified as having been diagnosed with metastatic cancer. Log transformed D-dimer levels were significantly higher in those with occult cancer as compared with patients without diagnosis of occult cancer (3.5±0.5 vs. 3.2±0.5, P-value = 0.009, respectively). D-dimer levels >4,000 ng/ml was independently associated with occult cancer (HR: 4.12, 95% CI: 1.54-11.04, P-value = 0.005) when compared with D-dimer levels <2,000 ng/ml, even after adjusting for age, gender, and type of VTE (e.g., deep vein thrombosis or pulmonary thromboembolism). D-dimer levels >4000 ng/ml were also associated with a higher likelihood of metastatic cancer (HR: 9.55, 95% CI: 2.46-37.17, P-value <0.001). Elevated D-dimer concentrations >4000 ng/ml are independently associated with the likelihood of occult cancer among patients with unprovoked VTE.

  7. Prevalence, risk factors, and impact of isolated antibody to hepatitis B core antigen and occult hepatitis B virus infection in HIV-1-infected pregnant women.

    PubMed

    Khamduang, Woottichai; Ngo-Giang-Huong, Nicole; Gaudy-Graffin, Catherine; Jourdain, Gonzague; Suwankornsakul, Weerapong; Jarupanich, Tapnarong; Chalermpolprapa, Veeradate; Nanta, Sirisak; Puarattana-Aroonkorn, Noossara; Tonmat, Sakchai; Lallemant, Marc; Goudeau, Alain; Sirirungsi, Wasna

    2013-06-01

    Prevalence and risk factors for isolated antibody to hepatitis B core antigen (anti-HBc) and occult hepatitis B virus (HBV) infection are not well known in human immunodeficiency virus type 1 (HIV-1)-infected pregnant women. It is unclear if women with occult infections are at risk of transmitting HBV to their infants. HIV-1-infected and HBV surface antigen (HBsAg)-negative pregnant women were tested for antibody to HBsAg (anti-HBs) and anti-HBc using enzyme immunoassay. Women with isolated anti-HBc were assessed for occult HBV infection, defined as HBV DNA levels >15 IU/mL, using the Abbott RealTime HBV DNA assay. Infants born to women with isolated anti-HBc and detectable HBV DNA were tested at 4 months of age for HBV DNA. Logistic regression analysis was used to identify factors associated with isolated anti-HBc and occult HBV infection. Among 1812 HIV-infected pregnant women, 1682 were HBsAg negative. Fourteen percent (95% confidence interval [CI], 12%-15%) of HBsAg-negative women had an isolated anti-HBc that was independently associated with low CD4 count, age >35 years, birth in northern Thailand, and positive anti-hepatitis C virus serology. Occult HBV infection was identified in 24% (95% CI, 18%-30%) of women with isolated anti-HBc, representing 2.6% (95% CI, 1.9%-3.5%) of HIV-1-infected pregnant women, and was inversely associated with HIV RNA levels. None of the women with isolated anti-HBc and occult HBV infection transmitted HBV to their infants. HIV-1-infected pregnant women with isolated anti-HBc and occult HBV infection have very low HBV DNA levels and are thus at very low risk to transmit HBV to their infants.

  8. Ground-based Light Curves Two Pluto Days Before the New Horizons Passage

    NASA Astrophysics Data System (ADS)

    Bosh, A. S.; Pasachoff, J. M.; Babcock, B. A.; Durst, R. F.; Seeger, C. H.; Levine, S. E.; Abe, F.; Suzuki, D.; Nagakane, M.; Sickafoose, A. A.; Person, M. J.; Zuluaga, C.; Kosiarek, M. R.

    2015-12-01

    We observed the occultation of a 12th magnitude star, one of the two brightest occultation stars ever in our dozen years of continual monitoring of Pluto's atmosphere through such studies, on 29 June 2015 UTC. At Canterbury University's Mt. John University Observatory on the south island of New Zealand, in clear sky, we used our POETS frame-transfer CCD at 10 Hz with GPS timing on the 1-m McLellan telescope as well as an infrared camera on an 0.6-m telescope and three-color photometry at a slower cadence on a second 0.6-m telescope. The light curves show a central flash, indicating that we were close to the center of the occultation path, and allowing us to explore Pluto's atmosphere lower than usual. The light curves show that Pluto's atmosphere remained robust. Observations from 0.5- and 0.4-m telescopes at the Auckland Observatory gave the first half of the occultation before clouds came in. We coordinated our observations with aircraft observations with NASA's Stratospheric Observatory for Infrared Astronomy (SOFIA) and its High Speed Imaging Photometer for Occultations (HIPO). Our ground-based and airborne stellar-occultation effort came only just over two weeks of Earth days and two Pluto days (based on Pluto's rotational period) before the flyby of NASA's New Horizons spacecraft, meaning that the mission's exquisite snapshot of Pluto's atmosphere can be placed in the context of our series of ground-based occultation observations carried out on a regular basis since 2002 following a first Pluto occultation observed in 1988 from aloft. Our observations were supported by NASA Planetary Astronomy grants NNX12AJ29G to Williams College, NNX15AJ82G to Lowell Observatory, and NNX10AB27G to MIT, and by the National Research Foundation of South Africa. We thank Alan Gilmore, Pam Kilmartin, Robert Lucas, Paul Tristam, and Carolle Varughese for assistance at Mt. John.

  9. Impact of fecal occult blood on obscure gastrointestinal bleeding: Observational study

    PubMed Central

    Kobayashi, Yuka; Watabe, Hirotsugu; Yamada, Atsuo; Suzuki, Hirobumi; Hirata, Yoshihiro; Yamaji, Yutaka; Yoshida, Haruhiko; Koike, Kazuhiko

    2015-01-01

    AIM: To elucidate the association between small bowel diseases (SBDs) and positive fecal occult blood test (FOBT) in patients with obscure gastrointestinal bleeding (OGIB). METHODS: Between February 2008 and August 2013, 202 patients with OGIB who performed both capsule endoscopy (CE) and FOBT were enrolled (mean age; 63.6 ± 14.0 years, 118 males, 96 previous overt bleeding, 106 with occult bleeding). All patients underwent immunochemical FOBTs twice prior to CE. Three experienced endoscopists independently reviewed CE videos. All reviews and consensus meeting were conducted without any information on FOBT results. The prevalence of SBDs was compared between patients with positive and negative FOBT. RESULTS: CE revealed SBDs in 72 patients (36%). FOBT was positive in 100 patients (50%) and negative in 102 (50%). The prevalence of SBDs was significantly higher in patients with positive FOBT than those with negative FOBT (46% vs 25%, P = 0.002). In particular, among patients with occult OGIB, the prevalence of SBDs was higher in positive FOBT group than negative FOBT group (45% vs 18%, P = 0.002). On the other hand, among patients with previous overt OGIB, there was no significant difference in the prevalence of SBDs between positive and negative FOBT group (47% vs 33%, P = 0.18). In disease specific analysis among patients with occult OGIB, the prevalence of ulcer and tumor were higher in positive FOBT group than negative FOBT group. In multivariate analysis, only positive FOBT was a predictive factors of SBDs in patients with OGIB (OR = 2.5, 95%CI: 1.4-4.6, P = 0.003). Furthermore, the trend was evident among patients with occult OGIB who underwent FOBT on the same day or a day before CE. The prevalence of SBDs in positive vs negative FOBT group were 54% vs 13% in patients with occult OGIB who underwent FOBT on the same day or the day before CE (P = 0.001), while there was no significant difference between positive and negative FOBT group in those who underwent FOBT two or more days before CE (43% vs 25%, P = 0.20). CONCLUSION: The present study suggests that positive FOBT may be useful for predicting SBDs in patients with occult OGIB. Positive FOBT indicates higher likelihood of ulcers or tumors in patients with occult OGIB. Undergoing CE within a day after FOBT achieved a higher diagnostic yield for patients with occult OGIB. PMID:25574108

  10. Il sistema multiplo di Spica osservato dal Padre Giovanni Battista Audiffredi nel 1753

    NASA Astrophysics Data System (ADS)

    Sigismondi, Costantino

    2005-06-01

    The multiplicity of Spica's system has been first observed in 1753 by the dominican father Giovanni Battista Audiffredi through a lunar occultation. Audiffredi noted that the emersion's duration from the bright lunar limb was not instantaneous. Nowadays Spica has five known components, four of them have been discovered by occultation. This observation is presented along with a general introduction of lunar occultations, Watts' profiles, Cassini regions and grazes.

  11. Wave optics of the central spot in planetary occultations

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.

    1977-01-01

    The detection of a bright central spot during the occultation of epsilon Geminorum by Mars demonstrates that an exponentially-stratified planetary atmosphere can act as a lens providing very high resolution of distant objects (e.g., quasars, white dwarfs, and pulsars). The diffraction nature of the central occultation spot is investigated, with special reference to Mars and Venus. In practice, however, central occultations by these planets are seldom observable from the earth's surface, and spacecraft would have to be used to obtain a suitable orientation for observers. Further difficulties may be encountered in image deconvolution needed for extended objects, in location of the image of a true point source, and in compensation for peculiarities of planets and their atmospheres.

  12. The occultation of Kappa Geminorum by Eros. [stellar occultation observed for asteroid size and shape

    NASA Technical Reports Server (NTRS)

    Oleary, B.; Marsden, B. G.; Dragon, R.; Hauser, E.; Mcgrath, M.; Backus, P.; Robkoff, H.

    1976-01-01

    The paper discusses predictions and observations of the occultation of Kappa Gem by (433) Eros on January 24, 1975. Several positive and negative observations made in western New England are described. Local circumstances for the occultation are reconstructed, and the size and shape of Eros are determined analytically as well as graphically. The calculations yield two extremes for the cross section: a circle 23 km in diameter or a somewhat irregular figure 20 km by 6 or 7 km. Arguments based on the expected albedo of the asteroid suggest that the circle should be warped into an ellipse 21 by 13 km or that the irregular figure might be one component of a dumbbell-like profile.

  13. Chiron stellar occultation candidates: 1993-1996

    NASA Technical Reports Server (NTRS)

    Bus, S. J.; Wasserman, L. H.; Elliot, J. L.

    1994-01-01

    A photographic search was conducted for stars that may be occulted by the unusual solar system object (2060) Chiron during the period from fall 1993 through summer 1996. 44 candidates were identified to a limiting V magnitude of 16, and for which the minimum appulse separation with Chiron is predicted to be less than 2.5 arcsec. The successful observation of a stellar occultation by Chiron would give a direct measure of its diameter (currently estimated to be between 60 and 300 km), and would help considerably in constraining Chiron's surface properties and volatile makeup. If at the time of the occultation, Chiron exhibits a significant coma, there is also the potential for measuring the optical-depth profile of the dust in its inner coma.

  14. The occult submucous cleft palate.

    PubMed

    Kaplan, E N

    1975-10-01

    We have studied 41 patients with classic submucous cleft and 32 cases with occult submucous cleft. Both groups have the same anatomic abnormality that leads to velar dysfunction-the insertion of the palate muscles onto the hard palate rather than onto the midline soft palate raphe. However, the occult submucous cleft palate does not have the classic triad of bifid uvula, hard palate bony notch, and furrow in the midline of the soft palate. Characteristic facial features, cephalmetric x-rays, and cine voice studies can help make a presumptive diagnosis of occult submucous cleft palate. Surgical management includes a diagnostic palate exploration to identify muscle configuration followed by levator muscle sling reconstruction, palate pushback, and pharyngeal flap. Excellent speech results are obtained except with patients having palate paresis.

  15. Stellar occultation of polarized light from circumstellar electrons. I - Flat envelopes viewed edge on

    NASA Technical Reports Server (NTRS)

    Brown, John C.; Fox, Geoffrey K.

    1989-01-01

    The depolarizing and occultation effects of a finite spherical light source on the polarization of light Thomson-scattered from a flat circumstellar envelope seen edge-on are analyzed. The analysis shows that neglect of the finite size of the light source leads to a gross overestimate of the polarization for a given disk geometry. By including occultation and depolarization, it is found that B-star envelopes are necessarily highly flattened disk-type structures. For a disk viewed edge-on, the effect of occultation reduces the polarization more than the inclusion of the depolarization factor alone. Analysis of a one-dimensional plume leads to a powerful technique that permits the electron density distribution to be explicitly obtained from the polarimetric data.

  16. Helios-1 Faraday rotation experiment - Results and interpretations of the solar occultations in 1975

    NASA Technical Reports Server (NTRS)

    Volland, H.; Bird, M. K.; Levy, G. S.; Stelzried, C. T.; Seidel, B. L.

    1977-01-01

    The first of two solar occultations of the satellite Helios-1 in 1975 occurred in April when the satellite's ray path approached the west limb of the sun to a minimum distance of 1.63 solar radii. The second occultation took place in late August/early September when Helios-1 was totally eclipsed by the photosphere. Measurements of the polarization angle of the linearly polarized telemetry signal were performed with automatic tracking polarimeters at the 64 m Goldstone Tracking Station in California and also at the 100 m radio telescope in Effelsberg, West Germany. The coronal Faraday rotation as a function of the solar offset for both occultations is shown in graphs. The theoretical significance of the observations is investigated.

  17. Predictions of stellar occultations by TNOs/Centaurs using Gaia

    NASA Astrophysics Data System (ADS)

    Desmars, Josselin; Camargo, Julio; Berard, Diane; Sicardy, Bruno; Leiva, Rodrigo; Vieira-Martins, Roberto; Braga-Ribas, Felipe; Assafin, Marcelo; Rossi, Gustavo; Chariklo occultations Team, Rio Group, Lucky Star Occultation Team, Granada Occultation Team

    2017-10-01

    Stellar occultations are the unique technique from the ground to access physical parameters of the distant solar system objects, such as the measure of the size and the shape at kilometric level, the detection of tenuous atmospheres (few nanobars), and the investigation of close vicinity (satellites, rings, jets).Predictions of stellar occultations require accurate positions of the star and the object.The Gaia DR1 catalog now allows to get stellar position to the milliarcsecond (mas) level. The main uncertainty in the prediction remains in the position of the object (tens to hundreds of mas).Now, we take advantage of the NIMA method for the orbit determination that uses the most recent observations reduced by the Gaia DR1 catalog and the astrometric positions derived from previous positive occultations.Up to now, we have detected nearly 50 positive occultations for about 20 objects that provide astrometric positions of the object at the time of the occultation. The uncertainty of these positions only depends on the uncertainty on the position of the occulted stars, which is a few mas with the Gaia DR1 catalog. The main limitation is now on the proper motion of the star which is only given for bright stars in the Tycho-Gaia Astrometric Solution. This limitation will be solved with the publicationof the Gaia DR2 expected on April 2018 giving proper motions and parallaxes for the Gaia stars. Until this date, we use hybrid stellar catalogs (UCAC5, HSOY) that provide proper motions derived from Gaia DR1 and another stellar catalog.Recently, the Gaia team presented a release of three preliminary Gaia DR2 stellar positions involved in the occultations by Chariklo (22 June and 23 July 2017) and by Triton (5 October 2017).Taking the case of Chariklo as an illustration, we will present a comparison between the proper motions of DR2 and the other catalogs and we will show how the Gaia DR2 will lead to a mas level precision in the orbit and in the prediction of stellar occultations.**Part of the research leading to these results has received funding from the European Research Council under theEuropean Community’s H2020 (2014-2020/ ERC Grant Agreement n 669416 ”LUCKY STAR”).

  18. Pluto's Atmospheric Figure from the P131.1 Stellar Occultation

    NASA Astrophysics Data System (ADS)

    Person, M. J.; Elliot, J. L.; Clancy, K. B.; Kern, S. D.; Salyk, C. V.; Tholen, D. J.; Pasachoff, J. M.; Babcock, B. A.; Souza, S. P.; Ticehurst, D. R.; Hall, D.; Roberts, L. C., Jr.; Bosh, A. S.; Buie, M. W.; Dunham, E. W.; Olkin, C. B.; Taylor, B.; Levine, S. E.; Eikenberry, S. S.; Moon, D.-S.; Osip, D. J.

    2003-05-01

    The stellar occultation by Pluto of the 15th magnitude star designated P131.1 (McDonald and Elliot, AJ, 119, 1999) on 2002 August 21 (UT) provided the first significant chance to compare Pluto's atmospheric structure to that determined from the 1988 occultation of P8 (Millis, et al., Icarus, 105, 282). The P131.1 occultation was observed from several stations in Hawaii and the western United States (Elliot et al., Nature, in press, 2003). Numerous occultation chords were obtained enabling us to examine Pluto's atmospheric figure. The light curves from the observations were analyzed together in the occultation coordinate system of Elliot et al., (AJ, 106, 2544). The Mauna Kea and Lick datasets straddle the center of Pluto's figure, providing strong constraints on model fits to cross sections of the atmospheric shape. In 1988, Millis (et al., Icarus, 105, 282) did not report any deviation from sphericity in Pluto's atmospheric figure. From the 2002 data, Pluto;s isobars at the radii probed by the occultation ( 1250 km) appear to be distorted from a circular cross-section. Least-squares fits to this cross-section by elliptical models reveal ellipticities in the range 0.05-0.08 although the shape may be more complex than ellipsoidal. The orientation of the distortion appears uncorrelated with Pluto;s rotational axis. Taken at face value, this ellipticity could imply wind speeds of up to twice the sonic speed ( 200 m/s), which would be difficult to explain. Similar distortions have been reported for Triton's atmosphere (Elliot, J. L., et al., Icarus 148, 347). This work has been supported in part by Research Corporation, the Air Force Research Laboratory, NSF, and NASA.

  19. Stellar Occultations by Large TNOs on 2012: The February 3rd by (208996) 2003 AZ84, and the February 17th by (50000) Quaoar

    NASA Astrophysics Data System (ADS)

    Braga Ribas, Felipe; Sicardy, B.; Ortiz, J. L.; Duffard, R.; Camargo, J. I. B.; Lecacheux, J.; Colas, F.; Vachier, F.; Tanga, P.; Sposetti, S.; Brosch, N.; Kaspi, S.; Manulis, I.; Baug, T.; Chandrasekhar, T.; Ganesh, S.; Jain, J.; Mohan, V.; Sharma, A.; Garcia-Lozano, R.; Klotz, A.; Frappa, E.; Jehin, E.; Assafin, M.; Vieira Martins, R.; Behrend, R.; Roques, F.; Widemann, T.; Morales, N.; Thirouin, A.; Mahasena, P.; Benkhaldoun, Z.; Daassou, A.; Rinner, C.; Ofek, E. O.

    2012-10-01

    On February 2012, two stellar occultation's by large Trans-neptunian Objects (TNO's) were observed by our group. On the 3rd, an event by (208996) 2003 AZ84 was recorded from Mont Abu Observatory and IUCAA Girawali Observatory in India and from Weizmann Observatory in Israel. On the 17th, a stellar occultation by (50000) Quaoar was observed from south France and Switzerland. Both occultations are the second observed by our group for each object, and will be used to improve the results obtained on the previous events. The occultation by 2003 AZ84 is the first multi-chord event recorded for this object. From the single chord event on January 8th 2011, Braga-Ribas et al. 2011 obtained a lower limit of 573 +/- 21 km. From the 2012 occultation the longest chord has a size of 662 +/- 50 km. The other chords will permit to determine the size and shape of the TNO, and derive other physical parameters, such as the geometric albedo. The Quaoar occultation was observed from south of France (Observatoire de la Côte d'Azur, TAROT telescope and Valensole) and from Gnosca, Switzerland. Unfortunately, all three sites in France are almost at the same Quaoar's latitude, so in practice, we have two chords that can be used to fit Quaoar's limb. The resulting fit will be compared with the results obtained by Braga-Ribas et al. 2011. Braga-Ribas F., Sicardy B., et al. 2011, EPSC-DPS2011, 1060.Ribas F., Sicardy B., et al. 2011, EPSC-DPS2011, 1060.

  20. Endoplasmic reticulum stress in complex atypical hyperplasia as a possible predictor of occult carcinoma and progestin response.

    PubMed

    Tierney, Katherine E; Ji, Lingyun; Dralla, Shannon S; Yoo, Eunjeong; Yessaian, Annie; Pham, Huyen Q; Roman, Lynda; Sposto, Richard; Mhawech-Fauceglia, Paulette; Lin, Yvonne G

    2016-12-01

    Glucose-regulated protein (GRP)-78, the key regulator of endoplasmic reticulum (ER) stress, is associated with endometrial cancer (EC) development and progression. However, its role in the continuum from complex atypical hyperplasia (CAH) to EC is unknown and the focus of this study. 252 formalin-fixed, paraffin-embedded endometrial biopsies from patients with CAH diagnosed between 2003 and 2011 were evaluated for GRP78 expression by immunohistochemistry. Expression was also evaluated in subsequent biopsies from those patients treated with progestins. Differences in GRP78 expression were assessed using standard statistical methods. GRP78 expression was undetectable in 45(18%) patients with CAH, while 120(48%) CAH cases showed moderate/strong expression. Among women who ultimately underwent hysterectomy for CAH (n=134), 54(40%) had occult EC while 57(43%) had persistent CAH. Those with occult EC upon hysterectomy had significantly stronger GRP78 expression than those who did not have occult EC (p=0.007). Greater GRP78 expression within CAH remained independently associated with the presence of an occult EC (p=0.017). Thirty-four of 54 (63%) patients with occult EC had moderate/strong GRP78 expression compared to 36 of 80 (45%) patients with persistent CAH, benign or non-atypical hyperplastic endometrium. In those treated with progestins, samples with persistent CAH and EC were more likely to have high levels of GRP78 expression in the initial biopsies than those who responded (p=0.014). Increased GRP78 expression in untreated CAH correlates with the presence of an occult EC. In addition, CAH specimens with greater GRP78 expression may identify patients who are less likely to respond to progestin therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Prognostic Value of Occult Isolated Tumour Cells within Regional Lymph Nodes of Dogs with Malignant Mammary Tumours.

    PubMed

    Coleto, A F; Wilson, T M; Soares, N P; Gundim, L F; Castro, I P; Guimarães, E C; Bandarra, M B; Medeiros-Ronchi, A A

    2018-01-01

    Canine mammary tumours (CMTs) are the most common type of neoplasm in bitches. As in women, the presence of metastasis in regional lymph nodes is an important prognostic factor in bitches with mammary carcinomas, but the clinical significance of occult isolated tumour cells (ITCs) within lymph nodes is still undefined in this species. The effectiveness of immunohistochemistry (IHC) in identifying occult ITCs and micrometastasis (MIC) was compared with that of the conventional haematoxylin and eosin staining technique. The relationship between tumour size, histological type, histological grade and the presence of metastasis was evaluated. The overall survival (OS) of female dogs with occult mammary carcinomas and ITCs within lymph nodes was analysed. Fragments of mammary carcinoma and regional lymph nodes of 59 female dogs were also evaluated. Histological sections of mammary carcinoma and lymph node samples were studied for tumour diagnosis and lymph node samples were tested by IHC using a pan-cytokeratin antibody. It was found that 35.2% of occult ITCs and 2.8% of hidden MIC were detected when IHC was used. There was a good correlation between the size of the tumour and metastasis to the lymph nodes (P = 0.77). ITCs were observed more frequently in the medullary region (60.7%) and metastases in the cortical region (44.4%). There was no significant difference in the OS between female dogs with occult ITCs and lymph nodes without ITCs. IHC can detect occult tumour cells in lymph nodes that are negative by histopathological examination. Female dogs with nodal ITCs do not have lower survival. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Occult head injury is common in children with concern for physical abuse.

    PubMed

    Boehnke, Mitchell; Mirsky, David; Stence, Nicholas; Stanley, Rachel M; Lindberg, Daniel M

    2018-04-13

    Studies evaluating small patient cohorts have found a high, but variable, rate of occult head injury in children <2 years old with concern for physical abuse. The American College of Radiology (ACR) recommends clinicians have a low threshold to obtain neuroimaging in these patients. Our aim was to determine the prevalence of occult head injury in a large patient cohort with suspected physical abuse using similar selection criteria from previous studies. Additionally, we evaluated proposed risk factors for associations with occult head injury. This was a retrospective, secondary analysis of data collected by an observational study of 20 U.S. child abuse teams that evaluated children who underwent subspecialty evaluation for concern of abuse. We evaluated children <2 years old and excluded those with abnormal mental status, bulging fontanelle, seizure, respiratory arrest, underlying neurological condition, focal neurological deficit or scalp injury. One thousand one hundred forty-three subjects met inclusion criteria and 62.5% (714) underwent neuroimaging with either head computed tomography or magnetic resonance imaging. We found an occult head injury prevalence of 19.7% (141). Subjects with emesis (odds ratio [OR] 3.5, 95% confidence interval [CI] 1.8-6.8), macrocephaly (OR 8.5, 95% CI 3.7-20.2), and loss of consciousness (OR 5.1, 95% CI 1.2-22.9) had higher odds of occult head injury. Our results show a high prevalence of occult head injury in patients <2 years old with suspected physical abuse. Our data support the ACR recommendation that clinicians should have a low threshold to perform neuroimaging in patients <2 years of age.

  3. Risk factors of occult malignancy in patients with unprovoked venous thromboembolism.

    PubMed

    Robin, Philippe; Le Roux, Pierre-Yves; Tromeur, Cécile; Planquette, Benjamin; Prévot-Bitot, Nathalie; Lavigne, Christian; Pastre, Jean; Merah, Adel; Couturaud, Francis; Le Gal, Grégoire; Salaun, Pierre-Yves

    2017-11-01

    Venous thromboembolism (VTE) can occur as the first manifestation of an underlying occult malignancy. It remains unclear whether or not a better selection of high risk patients might lead to more efficient occult cancer screening strategies. Our aim was to assess the predictors of occult malignancy diagnosis in patients with unprovoked VTE. Univariate analyses were performed to assess the effect of candidate predictors on occult cancer detection in patients enrolled in a prospective, multicenter, randomized, controlled study (MVTEP study) whose primary aim was to compare a limited screening strategy with a strategy combining limited screening and FDG PET/CT in patients with unprovoked VTE. This trial is completed and registered with ClinicalTrials.gov, number NCT00964275. Between March 3, 2009, and August 18, 2012, 399 patients were included. Five patients withdrew consent and refused the use of their data, and no VTE was confirmed in 2 patients who were excluded from this analysis. A total of 25 (6.4%) out of the 392 analysed patients received a new diagnosis of malignancyduring the 2-years follow-up. Age≥50years (p=0.01), male gender (p=0.04), leukocytes count (p=0.01), and platelets count (p=0.03) were associated with occult cancer detection. Patients with leukocytosis or thrombocytosis had a risk of cancer way above 10%. Previous VTE and smoker status (combining previous and current smokers) were not associated with occult cancer diagnosis (p>0.05). Demographic characteristics (age and sex), and laboratory tests (high platelets and leukocytes counts) may be associated with cancer detection in patients withunprovoked VTE. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Treatment for occult hepatocellular carcinoma: does it offer survival advantages over symptom-driven treatment?

    PubMed

    Kim, Kwang Min; Kim, Jiyu; Sinn, Dong Hyun; Kim, Hye Seung; Kim, Kyunga; Kang, Wonseok; Gwak, Geum-Youn; Paik, Yong-Han; Choi, Moon Seok; Lee, Joon Hyeok; Koh, Kwang Cheol; Paik, Seung Woon

    2018-04-03

    In order to claim a benefit of screen-based diagnosis for asymptomatic individuals, treatment of occult disease needs to offer survival advantages compared to the treatment of symptomatic disease, yet information on this issue is scarce with regard to hepatocellular carcinoma (HCC) screening. A total of 3353 treatment-naïve, consecutive, newly diagnosed HCC patients [age: 57.9 ± 10.3, male: 2,689 (80.2%), hepatitis B virus: 2555 (76.2%)], diagnosed between 2010 and 2013 were analyzed. Data on the mode of detection was prospectively collected at the time of HCC diagnosis and was used to group patients into occult or symptomatic cases. Overall, 643 (19.2%) patients were symptomatic cases. The proportion of patients undergoing resection, radiofrequency ablation or transplantation were lower in symptomatic cases than occult cases (20.8 vs. 56.2%, p < .001). Survival was better in occult cases than symptomatic cases (71.2 vs. 30.4% at three-years, p < .001), with a multivariable-adjusted hazard ratio of 1.40 (95% confidence interval (CI), 1.24-1.58). When stratified by tumor stage, a survival benefit was not observed for patients diagnosed at modified International Union Against Cancer (mUICC) stage I, but presenting symptoms were diverse and nonspecific. In a statistical model adjusting for potential lead-time bias, the association between overall survival and the mode of detection was markedly attenuated and was no longer significant when the treatment modality was included in the model (hazard ratio, 0.94; 95% CI, 0.82-1.07). Treatment of occult disease offered a survival benefit to patients over symptomatic cases. These data support screening practices for asymptomatic individuals to diagnose occult HCC.

  5. Constraints on Pluto's Hazes from 2-Color Occultation Lightcurves

    NASA Astrophysics Data System (ADS)

    Hartig, Kara; Barry, T.; Carriazo, C. Y.; Cole, A.; Gault, D.; Giles, B.; Giles, D.; Hill, K. M.; Howell, R. R.; Hudson, G.; Loader, B.; Mackie, J. A.; Olkin, C. B.; Rannou, P.; Regester, J.; Resnick, A.; Rodgers, T.; Sicardy, B.; Skrutskie, M. F.; Verbiscer, A. J.; Wasserman, L. H.; Watson, C. R.; Young, E. F.; Young, L. A.; Buie, M. W.; Nelson, M.

    2015-11-01

    The controversial question of aerosols in Pluto's atmosphere first arose in 1988, when features in a Pluto occultation lightcurve were alternately attributed to haze opacity (Elliot et al. 1989) or a thermal inversion (Eshleman 1989). A stellar occultation by Pluto in 2002 was observed from several telescopes on Mauna Kea in wavelengths ranging from R- to K-bands (Elliot et al. 2003). This event provided compelling evidence for haze on Pluto, since the mid-event baseline levels were systematically higher at longer wavelengths (as expected if there were an opacity source that scattered more effectively at shorter wavelengths). However, subsequent occultations in 2007 and 2011 showed no significant differences between visible and IR lightcurves (Young et al. 2011).The question of haze on Pluto was definitively answered by direct imaging of forward-scattering aerosols by the New Horizons spacecraft on 14-JUL-2015. We report on results of a bright stellar occultation which we observed on 29-JUN-2015 in B- and H-bands from both grazing and central sites. As in 2007 and 2011, we see no evidence for wavelength-dependent extinction. We will present an analysis of haze parameters (particle sizes, number density profiles, and fractal aggregations), constraining models of haze distribution to those consistent with and to those ruled out by the occultation lightcurves and the New Horizons imaging.References:Elliot, J.L., et al., "Pluto's Atmosphere." Icarus 77, 148-170 (1989)Eshleman, V.R., "Pluto's Atmosphere: Models based on refraction, inversion, and vapor pressure equilibrium." Icarus 80 439-443 (1989)Elliot, J.L., et al., "The recent expansion of Pluto's atmosphere." Nature 424 165-168 (2003)Young, E.F., et al., "Search for Pluto's aerosols: simultaneous IR and visible stellar occultation observations." EPSC-DPS Joint Meeting 2011, held 2-7 October 2011 in Nantes, France (2011)

  6. A New Look at Triton's Atmosphere

    NASA Astrophysics Data System (ADS)

    Person, Michael

    When it was first examined with stellar occultations in the 1990s, Triton's atmosphere was seen to undergo global expansion during the period from 1993 to 1997. This expansion was confirmed as a continuing phenomenon with a stellar occultation observation in 2001 . Unfortunately, as Triton started to pass through a fairly sparse star field, occultation observations have been much more difficult to make. There have been no published occultation data on Triton's atmosphere since the 2001 event, and reported observations in early 2007 had too low of a signal-to-noise ratio to say anything about the atmospheric profile. Thus, it has been over 15 years since the last direct measurement of Triton's expanding atmosphere was made, leaving wide open the question of Triton's current atmospheric state. Is the atmosphere still expanding or is it now collapsing? Are the haze layers seen by Voyager still present? Are the variations seen in the 1990s seasonal or cyclic on shorter time scales due to Triton surface processes? The observation of stellar occultations remains the only way to gain current data on Triton's atmosphere from Earth, and SOFIA's unique ability to be reliably placed in the central flash region of occultation events where the richest dataset is available, and its immunity to low-level weather disturbances make it the ideal platform for updating our knowledge on Triton and beginning to answer these many outstanding questions. We therefore propose to use SOFIA with HIPO, FLITECAM (FLIPO), and the FPI+ to measure temperature, pressure, and particulate haze radial profiles of Triton's atmosphere by observing a stellar occultation which will be visible over the eastern portion of North America in October of 2017. We expect to use FLITECAM/HIPO (FLIPO) Guaranteed Time Observing (GTO) hours for the included observations with the agreement of the FLITECAM and HIPO instrument teams.

  7. Atmospheric characterization of the hot Jupiter Kepler-13Ab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shporer, Avi; O'Rourke, Joseph G.; Knutson, Heather A.

    Kepler-13Ab (= KOI-13.01) is a unique transiting hot Jupiter. It is one of very few known short-period planets orbiting a hot A-type star, making it one of the hottest planets currently known. The availability of Kepler data allows us to measure the planet's occultation (secondary eclipse) and phase curve in the optical, which we combine with occultations observed by warm Spitzer at 4.5 μm and 3.6 μm and a ground-based occultation observation in the K{sub s} band (2.1 μm). We derive a day-side hemisphere temperature of 2750 ± 160 K as the effective temperature of a black body showing themore » same occultation depths. Comparing the occultation depths with one-dimensional planetary atmosphere models suggests the presence of an atmospheric temperature inversion. Our analysis shows evidence for a relatively high geometric albedo, A {sub g} = 0.33{sub −0.06}{sup +0.04}. While measured with a simplistic method, a high A {sub g} is supported also by the fact that the one-dimensional atmosphere models underestimate the occultation depth in the optical. We use stellar spectra to determine the dilution, in the four wide bands where occultation was measured, due to the visual stellar binary companion 1.''15 ± 0.''05 away. The revised stellar parameters measured using these spectra are combined with other measurements, leading to revised planetary mass and radius estimates of M{sub p} = 4.94-8.09 M {sub J} and R{sub p} = 1.406 ± 0.038 R {sub J}. Finally, we measure a Kepler midoccultation time that is 34.0 ± 6.9 s earlier than expected based on the midtransit time and the delay due to light-travel time and discuss possible scenarios.« less

  8. Methodology of Evaluating the Science Benefit of Various Satellite/Sensor Constellation Orbital Parameters to an Assimilative Data Forecast Model

    DTIC Science & Technology

    2015-03-02

    and Aurora Spectrograph) inst1uments, and radio 129 occultation data from CHAMP (Challenging Minisatellite Payload), SAC-C (Satellite de 130...Aplicaciones Cientificas-C) [Hajj et al, 2004], IOX (Ionospheric Occultation Experiment) 131 [Straus et al, 2003], and the COSMIC (Constellation Observing...T. K. Meehan, L. 385 J. Romans, M. de la Torre Juarez. and T. P. Yunck (2004), CHAMP and SAC-C atmospheric 386 occultation results and

  9. The Regulus occultation light curve and the real atmosphere of Venus

    NASA Technical Reports Server (NTRS)

    Veverka, J.; Wasserman, L.

    1974-01-01

    An inversion of the light curve observed during the July 7, 1959, occultation of Regulus by Venus leads to the conclusion that the light curve cannot be reconciled with models of the Venus atmosphere based on spacecraft observations. The event occurred in daylight and, under the subsequently difficult observation conditions, it seems likely that the Regulus occultation light curve is marred by a systematic errors in spite of the competence of the observers involved.

  10. Winds and the occultation experiment. [for Venus and Mars atmospheric parameters

    NASA Technical Reports Server (NTRS)

    Gross, S. H.

    1974-01-01

    A spacecraft orbiting about another planet, such as Mars or Venus, may be used to obtain data about the pressure, density, and temperature fields over the planet from multiple occultations if the orbit precesses or retrogresses. Under certain conditions successive occultations will provide mean dynamic information such as wind speeds over the time and spacing intervals. It is shown that data concerning winds may be found by comparing refractivity information rather than pressure or temperature.

  11. VizieR Online Data Catalog: Outer satellites occultation predictions (Gomes-Junior+, 2016)

    NASA Astrophysics Data System (ADS)

    Gomes-Junior, A. R.; Assafin, M.; Beauvalet, L.; Desmars, J.; Vieira-Martins, R.; Camargo, J. I. B.; Morgado, B. E.; Braga-Ribas, F.

    2016-07-01

    Tables contain the day of the year and UTC central instant of the prediction; right ascension and declination of the occulted star - at the central instant of the occultation (corrected by proper motions); C/A: apparent geocentric distance between the satellite and the star (a.k.a. the distance between the shadow and the center of the Earth) at the moment of the geocentric closest approach, in arcseconds; P/A: the satellite position angle with respect to the occulted star at C/A, in degrees (zero at north of the star, increasing clockwise); v: relative velocity of event in km/s: positive = prograde, negative = retrograde; D: Geocentric distance to the occulting object in AU; R*: normalized UCAC4 magnitude in the R-band to a common shadow of 20km/s by the relationship R*=RUCAC4+2.5xlog(velocity/(20km/s)), the value 20km/s is typical of events around the opposition; long: east longitude of subplanet point in degrees, positive towards east, at the instant of the geocentric closest approach; LST: UT + long: local solar time at subplanet point, hh:mm; pmra and pmdec: proper motions in right ascension and declination, respectively (mas/year). For more detailed information about the definition and use of these stellar occultation geometric elements see Assafin et al. (2010, Cat. J/A+A/515/A32). (2 data files).

  12. Occult hepatitis B virus infection and S gene escape mutants in HIV-infected patients after hepatitis B virus vaccination.

    PubMed

    Aghakhani, Arezoo; Mohraz, Minoo; Aghasadeghi, Mohammad Reza; Banifazl, Mohammad; Vahabpour, Rouhollah; Karami, Afsaneh; Foroughi, Maryam; Ramezani, Amitis

    2016-10-01

    Hepatitis B virus (HBV) vaccination is recommended for HIV patients. Despite the relative success of HBV vaccination, breakthrough infections can occur infrequently in patients, and it can be due to occult HBV infection, vaccine unresponsiveness and/or emergence of escape mutants. This study assessed the presence of occult HBV infection and S gene escape mutants in HIV-positive patients after HBV vaccination. Ninety-two HIV-positive patients were enrolled in this study, including 52 responders to HBV vaccine and 40 non-responders. All of the cases received HBV vaccine according to routine HBV vaccination protocols. The presence of HBV-DNA was determined by real-time polymerase chain reaction (PCR). In HBV-DNA positive samples, the most conserved regions of S gene sequences were amplified by nested PCR and PCR products were sequenced. Occult HBV infection was detected in two cases. Glycine to arginine mutation at residue 145 (G145R) within the 'a' region of the S gene was detected in one of the occult HBV infection cases who was in the non-responder group. This study showed that the prevalence of occult HBV infection and vaccine escape mutants was low in our HBV-vaccinated HIV-positive patients in both responder and non-responder groups, so there was no alarming evidence indicating breakthrough HBV infection in our vaccinated HIV-positive cases. © The Author(s) 2016.

  13. Recurring sets of recurring starspot occultations on exoplanet host Qatar-2

    NASA Astrophysics Data System (ADS)

    Močnik, T.; Southworth, J.; Hellier, C.

    2017-10-01

    We announce the detection of recurring sets of recurring starspot occultation events in the short-cadence K2 light curve of Qatar-2, a K dwarf star transited every 1.34 d by a hot Jupiter. In total, we detect 34 individual starspot occultation events, caused by five different starspots, occulted in up to five consecutive transits or after a full stellar rotation. The longest recurring set of recurring starspot occultations spans over three stellar rotations, setting a lower limit for the longest starspot lifetime of 58 d. Starspot analysis provided a robust stellar rotational period measurement of 18.0 ± 0.2 d and indicates that the system is aligned, having a sky-projected obliquity of 0° ± 8°. A pronounced rotational modulation in the light curve has a period of 18.2 ± 1.6 d, in agreement with the rotational period derived from the starspot occultations. We tentatively detect an ellipsoidal modulation in the phase curve, with a semi-amplitude of 18 ppm, but cannot exclude the possibility that this is the result of red noise or imperfect removal of the rotational modulation. We detect no transit-timing and transit-duration variations with upper limits of 15 s and 1 min, respectively. We also reject any additional transiting planets with transit depths above 280 ppm in the orbital period region 0.5-30 d.

  14. Prediction of stellar occultations by distant solar system bodies in the Gaia era

    NASA Astrophysics Data System (ADS)

    Desmars, Josselin; Camargo, Julio; Sicardy, Bruno; Braga-Ribas, Felipe; Vieira-Martins, Roberto; Assafin, Marcelo; Bérard, Diane; Benedetti-Rossi, Gustavo

    2018-04-01

    Stellar occultations are a unique technique to access physical characteristics of distant solar system objects from the ground. They allow the measure of the size and the shape at kilometric level, the detection of tenuous atmospheres (few nanobars), and the investigation of close vicinity (satellites, rings) of Transneptunian objects and Centaurs. This technique is made successful thanks to accurate predictions of occultations. Accuracy of the predictions depends on the uncertainty in the position of the occulted star and the object's orbit. The Gaia stellar catalogue (Gaia Collaboration (2017)) now allows to get accurate astrometric stellar positions (to the mas level). The main uncertainty remains on the orbit. In this context, we now take advantage of the NIMA method (Desmars et al.(2015)) for the orbit determination and of the Gaia DR1 catalogue for the astrometry. In this document, we show how the orbit determination is improved by reducing current and some past observations with Gaia DR1. Moreover, we also use more than 45 past positive occultations observed in the 2009-2017 period to derive very accurate astrometric positions only depending on the position of the occulted stars (about few mas with Gaia DR1). We use the case of (10199) Chariklo as an illustration. The main limitation lies in the imprecision of the proper motions which is going to be solved by the Gaia DR2 release.

  15. Technical Note: A Time-Dependent I(sub 0) Correction for Solar Occultation Instruments

    NASA Technical Reports Server (NTRS)

    Burton, Sharon P.; Thomason, Larry W.; Zawodny, Joseph M.

    2009-01-01

    Solar occultation has proven to be a reliable technique for the measurement of atmospheric constituents in the stratosphere. NASA's Stratospheric Aerosol and Gas Experiments (SAGE, SAGE II, and SAGE III) together have provided over 25 years of quality solar occultation data, a data record which has been an important resource for the scientific exploration of atmospheric composition and climate change. Herein, we describe an improvement to the processing of SAGE data that corrects for a previously uncorrected short-term timedependence in the calibration function. The variability relates to the apparent rotation of the scanning track with respect to the face of the sun due to the motion of the satellite. Correcting for this effect results in a decrease in the measurement noise in the Level 1 line-of-sight optical depth measurements of approximately 40% in the middle and upper stratospheric SAGE II and III where it has been applied. The technique is potentially useful for any scanning solar occultation instrument, and suggests further improvement for future occultation measurements if a full disk imaging system can be included.

  16. Radio scintillations observed during atmospheric occultations of Voyager: Internal gravity waves at Titan and magnetic field orientations at Jupiter and Saturn. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Hinson, D. P.

    1983-01-01

    The refractive index of planetary atmospheres at microwave frequencies is discussed. Physical models proposed for the refractive irregularities in the ionosphere and neutral atmosphere serve to characterize the atmospheric scattering structures, and are used subsequently to compute theoretical scintillation spectra for comparison with the Voyager occultation measurements. A technique for systematically analyzing and interpreting the signal fluctuations observed during planetary occultations is presented and applied to process the dual-wavelength data from the Voyager radio occultations by Jupiter, Saturn, and Titan. Results concerning the plasma irregularities in the upper ionospheres of Jupiter and Saturn are reported. The measured orientation of the irregularities is used to infer the magnetic field direction at several locations in the ionospheres of these two planets; the occultation measurements conflict with the predictions of Jovian magnetic field models, but generally confirm current models of Saturn's field. Wave parameters, including the vertical fluxes of energy and momentum, are estimated, and the source of the internal gravity waves discovered in Titan's upper atmosphere is considered.

  17. PLUTO'S SEASONS: NEW PREDICTIONS FOR NEW HORIZONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, L. A.

    Since the last Pluto volatile transport models were published in 1996, we have (1) new stellar occultation data from 2002 and 2006-2012 that show roughly twice the pressure as the first definitive occultation from 1988, (2) new information about the surface properties of Pluto, (3) a spacecraft due to arrive at Pluto in 2015, and (4) a new volatile transport model that is rapid enough to allow a large parameter-space search. Such a parameter-space search coarsely constrained by occultation results reveals three broad solutions: a high-thermal inertia, large volatile inventory solution with permanent northern volatiles (PNVs; using the rotational northmore » pole convention); a lower thermal-inertia, smaller volatile inventory solution with exchanges of volatiles between hemispheres and a pressure plateau beyond 2015 (exchange with pressure plateau, EPP); and solutions with still smaller volatile inventories, with exchanges of volatiles between hemispheres and an early collapse of the atmosphere prior to 2015 (exchange with early collapse, EEC). PNV and EPP are favored by stellar occultation data, but EEC cannot yet be definitively ruled out without more atmospheric modeling or additional occultation observations and analysis.« less

  18. Stellar Occultation Studies of Pluto, Triton, Charon, and Chiron

    NASA Technical Reports Server (NTRS)

    Elliot, James L.

    2002-01-01

    Bodies inhabiting the outer solar system are of interest because, due to the colder conditions, they exhibit unique physical processes. Also, some of the lessons learned from them can be applied to understanding what occurred in the outer solar system during its formation and early evolution. The thin atmospheres of Pluto and Triton have structure that is not yet understood, and they have been predicted to undergo cataclysmic seasonal changes. Charon may have an atmosphere - we don't know. Chiron exhibits cometary activity so far from the sun (much further than most comets), so that H2O sublimation cannot be the driving mechanism. Probing these bodies from Earth with a spatial resolution of a few kilometers can be accomplished only with the stellar occultation technique. In this program we find and predict stellar occultation events by small outer-solar system bodies and then attempt observations of the ones that can potentially answer interesting questions. We also develop new methods of data analysis for occultations and secure other observations that are necessary for interpretation of the occultation data.

  19. The Prediction and Observation of the 1997 July 18 Stellar Occultation by Triton: More Evidence for Distortion and Increasing Pressure in Triton's Atmosphere

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Person, M. J.; McDonald, S. W.; Buie, M. W.; Dunham, E. W.; Millis, R. L.; Nye, R. A.; Olkin, C. B.; Wasserman, L. H.; Young, L. A.

    2000-01-01

    We used CCD (charge coupled device) astrometric data to predict where the occultation path of the star Tr 176 was located, on July 18, 1997. It could be seen from northern Australia and the southern section of North America. We set up an array of portable and mixed telescopes which had high-speed photometric equipment to observe the occultation. Goals included the following: (1) mapping the central flash; (2) obtaining light curves for the signal-to-noise ratio; (3) acquiring light curves from Triton's disk. We combined these with data from others to find the radius and geometry of the half-light surface of the atmosphere, as well as the equivalent-isothermal temperature latitudes below the occultation on Triton.

  20. Close Double Stars from Occultation Video Recordings

    NASA Astrophysics Data System (ADS)

    Waring Dunham, David; George, Anthony; Loader, Brian; Herald, David Russell

    2015-08-01

    Astronomers around the world, both amateur and professional, have been recording lunar and asteroidal occultations of close double stars during the past several years using inexpensive but quite sensitive video cameras that are now available. Several new double stars have been discovered, and the parameters of many close systems have been determined. Besides rather good measurements of the relative magnitudes of the components, the actual separations and position angles can be measured if observations of the same event are made from two or more separate stations. These observations collected by the International Occultation Timing Association (IOTA) are published in the Journal of Double Star Observations. Recently, IOTA has encouraged the observation of occultations of stars in the Kepler 2 program, which is interested in data about close duplicity that affects their analyses for exoplanet transits.

  1. Wave optics-based LEO-LEO radio occultation retrieval

    NASA Astrophysics Data System (ADS)

    Benzon, Hans-Henrik; Høeg, Per

    2016-06-01

    This paper describes the theory for performing retrieval of radio occultations that use probing frequencies in the XK and KM band. Normally, radio occultations use frequencies in the L band, and GPS satellites are used as the transmitting source, and the occultation signals are received by a GPS receiver on board a Low Earth Orbit (LEO) satellite. The technique is based on the Doppler shift imposed, by the atmosphere, on the signal emitted from the GPS satellite. Two LEO satellites are assumed in the occultations discussed in this paper, and the retrieval is also dependent on the decrease in the signal amplitude caused by atmospheric absorption. The radio wave transmitter is placed on one of these satellites, while the receiver is placed on the other LEO satellite. One of the drawbacks of normal GPS-based radio occultations is that external information is needed to calculate some of the atmospheric products such as the correct water vapor content in the atmosphere. These limitations can be overcome when a proper selected range of high-frequency waves are used to probe the atmosphere. Probing frequencies close to the absorption line of water vapor have been included, thus allowing the retrieval of the water vapor content. Selecting the correct probing frequencies would make it possible to retrieve other information such as the content of ozone. The retrieval is performed through a number of processing steps which are based on the Full Spectrum Inversion (FSI) technique. The retrieval chain is therefore a wave optics-based retrieval chain, and it is therefore possible to process measurements that include multipath. In this paper simulated LEO to LEO radio occultations based on five different frequencies are used. The five frequencies are placed in the XK or KM frequency band. This new wave optics-based retrieval chain is used on a number of examples, and the retrieved atmospheric parameters are compared to the parameters from a global European Centre for Medium-Range Weather Forecasts analysis model. This model is used in a forward propagator that simulates the electromagnetic field amplitudes and phases at the receiver on board the LEO satellite. LEO-LEO cross-link radio occultations using high frequencies are a relatively new technique, and the possibilities and advantages of the technique still need to be investigated. The retrieval of this type of radio occultations is considerably more complicated than standard GPS to LEO radio occultations, because the attenuation of the probing radio waves is used in the retrieval and the atmospheric parameters are found using a least squares solver. The best algorithms and the number of probing frequencies that is economically viable must also be determined. This paper intends to answer some of these questions using end-to-end simulations.

  2. Occulting focal plane masks for Terrestrial Planet Finder Coronagraph: design, fabrication, simulations and test results

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatham; Hoppe, Daniel J.; Halverson, Peter G.; Wilson, Daniel W.; Echternach, Pierre M.; Shi, Fang; Lowman, Andrew E.; Niessner, Albert F.; Trauger, John T.; Shaklan, Stuart B.

    2005-01-01

    Occulting focal plane masks for the Terrestrial Planet Finder Coronagraph (TPF-C) could be designed with continuous gray scale profile of the occulting pattern such as 1-sinc2 on a suitable material or with micron-scale binary transparent and opaque structures of metallic pattern on glass. We have designed, fabricated and tested both kinds of masks. The fundamental characteristics of such masks and initial test results from the High Contrast Imaging Test bed (HCIT) at JPL are presented.

  3. Revised albedos of Trojan asteroids (911) Agamemnon and (4709) Ennomos

    NASA Astrophysics Data System (ADS)

    Shevchenko, V. G.; Slyusarev, I. G.; Belskaya, I. N.

    2014-01-01

    CCD-photometry was performed for two Jupiter Trojan asteroids (911) Agamemnon and (4709) Ennomos for which the diameters were obtained from occultation events. New data on rotation periods, lightcurve amplitudes, color indices, magnitude-phase slopes, and absolute magnitudes were obtained for these asteroids. We have used the diameters from occultations (166 and 99 km) and new data on absolute magnitudes at the instant occultation (7.95 and 8.85 mag) to revise their albedos to 0.042 (911 Agamemnon) and 0.052 (4709 Ennomos).

  4. Solar Occultation Retrieval Algorithm Development

    NASA Technical Reports Server (NTRS)

    Lumpe, Jerry D.

    2004-01-01

    This effort addresses the comparison and validation of currently operational solar occultation retrieval algorithms, and the development of generalized algorithms for future application to multiple platforms. initial development of generalized forward model algorithms capable of simulating transmission data from of the POAM II/III and SAGE II/III instruments. Work in the 2" quarter will focus on: completion of forward model algorithms, including accurate spectral characteristics for all instruments, and comparison of simulated transmission data with actual level 1 instrument data for specific occultation events.

  5. Flushable reagent stool blood test

    MedlinePlus

    Stool occult blood test - flushable home test; Fecal occult blood test - flushable home test ... This test is performed at home with disposable pads. You can buy the pads at the drug store without ...

  6. Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum

    NASA Technical Reports Server (NTRS)

    Shiri, Ron Shahram; Wasylkiwskyj, Wasyl

    2013-01-01

    The presence of the Poisson Spot, also known as the spot of Arago, has been known since the 18th century. This spot is the consequence of constructive interference of light diffracted by the edge of the obstacle where the central position can be determined by symmetry of the object. More recently, many NASA missions require the suppression of this spot in the visible range. For instance, the exoplanetary missions involving space telescopes require telescopes to image the planetary bodies orbiting central stars. For this purpose, the starlight needs to be suppressed by several orders of magnitude in order to image the reflected light from the orbiting planet. For the Earth-like planets, this suppression needs to be at least ten orders of magnitude. One of the common methods of suppression involves sharp binary petaled occulters envisioned to be placed many thousands of miles away from the telescope blocking the starlight. The suppression of the Poisson Spot by binary sharp petal tips can be problematic when the thickness of the tips becomes smaller than the wavelength of the incident beam. First they are difficult to manufacture and also it invalidates the laws of physical optics. The proposed partially transparent petaled masks/occulters compensate for this sharpness with transparency along the surface of the petals. Depending on the geometry of the problem, this transparency can be customized such that only a small region of the petal is transparent and the remaining of the surface is opaque. This feature allows easy fabrication of this type of occultation device either as a mask or occulter. A partially transparent petaled mask/ occulter has been designed for the visible spectrum range. The mask/occulter can suppress the intensity along the optical axis up to ten orders of magnitude. The design process can tailor the mask shape, number of petals, and transparency level to the near-field and farfield diffraction region. The mask/occulter can be used in space astronomy, ground-based telescope, and high-energy laser systems, and optical lithography to eliminate the Poisson Spot.

  7. Detection of Occult Invasion in Melanoma In Situ.

    PubMed

    Bax, Michael J; Johnson, Timothy M; Harms, Paul W; Schwartz, Jennifer L; Zhao, Lili; Fullen, Douglas R; Chan, May P

    2016-11-01

    It is unclear why some patients with in situ melanoma develop metastases. Few reports demonstrate occult invasion with immunohistochemistry staining, which were discordant with reports interpreting such staining as false-positive. To investigate the occurrence of occult invasive disease within in situ melanoma by using methods to circumvent potential limitations in prior study designs. Unequivocal in situ melanoma without associated nevi or regression was identified using a consecutive sample of 33 cases plus 1 index case in an academic medical center. After cutting deeper into the most representative tissue block, 3 sequential slides were stained with hematoxylin-eosin (H-E), melanoma antigen (melan-A), and again with H-E. Melan-A-stained slides showing definitive invasion were double-stained with Sry-related HMg-Box gene 10 (SOX10) to confirm the melanocytic nature of the cells of interest. The study evaluated the possibilities of occult invasion detected by immunohistochemistry, sectioning deeper into the tissue block, or both. Slides were independently scored by 3 dermatopathologists with interrater reliability assessed. The study was conducted from January 1, 2012, to July 31, 2014. Assessment of the occurrence of occult invasion, diagnosis of invasion by immunohistochemistry alone vs cutting deeper into the tissue block, and occurrence of false-positive results using immunohistochemistry alone. Occult invasive melanoma was detected in 11 of 33 consecutive cases (33%) of previously diagnosed unequivocal in situ melanoma. Six of 11 melanomas (55%) were diagnosable only by immunohistochemistry. The remaining 5 tumors (45%) were diagnosable by both melan-A and H-E staining, likely as a result of simply cutting deeper into the tissue block. Four cases (12%) showed a few melan-A-positive cells in the dermis, which was insufficient for a diagnosis of invasive melanoma and most consistent on a cytomorphologic basis with occult nevi. Although rare, in situ melanoma may metastasize. Occult microinvasion was demonstrated in up to one-third of the specimens in the present study, which provides a plausible explanation for this adverse event. Thus, history and physical examination including regional lymph nodes, education, and surveillance recommendations should be based on a very low, but not zero, risk of metastasis.

  8. Histopathological Parameters predicting Occult Nodal Metastases in Tongue Carcinoma Cases: An Indian Perspective.

    PubMed

    Jacob, Tina Elizabeth; Malathi, N; Rajan, Sharada T; Augustine, Dominic; Manish, N; Patil, Shankargouda

    2016-01-01

    It is a well-established fact that in squamous cell carcinoma cases, the presence of lymph node metastases decreased the 5-year survival rate by 50% and also caused the recurrence of the primary tumor with development of distant metastases. Till date, the predictive factors for occult cervical lymph nodes metastases in cases of tongue squamous cell carcinoma remain inconclusive. Therefore, it is imperative to identify patients who are at the greatest risk for occult cervical metastases. This study was thus performed with the aim to identify various histopathologic parameters of the primary tumor that predict occult nodal metastases. The clinicopathologic features of 56 cases of lateral tongue squamous cell carcinoma with cT1NoMo/cT2NoMo as the stage and without prior radiotherapy or chemotherapy were considered. The surgical excision of primary tumor was followed by elective neck dissection. The glossectomy specimen along with the neck nodes were fixed in formalin and 5 urn thick sections were obtained. The hematoxylin & eosin stained sections were then subjected to microscopic examination. The primary tumor characteristics that were analyzed include tumor grade, invading front, depth of tumor, lymphovascular invasion, perineural invasion and inflammatory response. The nodes were examined for possible metastases using hematoxylin & eosin followed by cytokeratin immunohistochemistry. A total of 12 cases were found with positive occult nodal metastases. On performing univariate analysis, the histopathologic parameters that were found to be statistically significant were lymphovascular invasion (p = 0.004) and perineural invasion (p = 0.003) along with a cut-off depth of infiltration more than 5 mm (p = 0.01). Histopathologic assessment of the primary tumor specimen therefore continues to provide information that is central to guide clinical management, particularly in cases of occult nodal metastases. Clinical significance The study highlights the importance of extensive histopathological screening, which holds the key for establishing occult metastases. Pathological upgrading of tumors is possible following histopathological studies similar to the present one. Presence of occult metastases justify neck dissection in these clinically N0 cases. In an Indian setting, histopathological evaluation assumes a bigger role than other expensive and advanced techniques.

  9. Effect of Occult Metastases on Survival in Node-Negative Breast Cancer

    PubMed Central

    Weaver, Donald L.; Ashikaga, Takamaru; Krag, David N.; Skelly, Joan M.; Anderson, Stewart J.; Harlow, Seth P.; Julian, Thomas B.; Mamounas, Eleftherios P.; Wolmark, Norman

    2011-01-01

    BACKGROUND Retrospective and observational analyses suggest that occult lymph-node metastases are an important prognostic factor for disease recurrence or survival among patients with breast cancer. Prospective data on clinical outcomes from randomized trials according to sentinel-node involvement have been lacking. METHODS We randomly assigned women with breast cancer to sentinel-lymph-node biopsy plus axillary dissection or sentinel-lymph-node biopsy alone. Paraffin-embedded tissue blocks of sentinel lymph nodes obtained from patients with pathologically negative sentinel lymph nodes were centrally evaluated for occult metastases deeper in the blocks. Both routine staining and immunohistochemical staining for cytokeratin were used at two widely spaced additional tissue levels. Treating physicians were unaware of the findings, which were not used for clinical treatment decisions. The initial evaluation at participating sites was designed to detect all macrometastases larger than 2 mm in the greatest dimension. RESULTS Occult metastases were detected in 15.9% (95% confidence interval [CI], 14.7 to 17.1) of 3887 patients. Log-rank tests indicated a significant difference between patients in whom occult metastases were detected and those in whom no occult metastases were detected with respect to overall survival (P = 0.03), disease-free survival (P = 0.02), and distant-disease–free interval (P = 0.04). The corresponding adjusted hazard ratios for death, any outcome event, and distant disease were 1.40 (95% CI, 1.05 to 1.86), 1.31 (95% CI, 1.07 to 1.60), and 1.30 (95% CI, 1.02 to 1.66), respectively. Five-year Kaplan-Meier estimates of overall survival among patients in whom occult metastases were detected and those without detectable metastases were 94.6% and 95.8%, respectively. CONCLUSIONS Occult metastases were an independent prognostic variable in patients with sentinel nodes that were negative on initial examination; however, the magnitude of the difference in outcome at 5 years was small (1.2 percentage points). These data do not indicate a clinical benefit of additional evaluation, including immunohistochemical analysis, of initially negative sentinel nodes in patients with breast cancer. (Funded by the National Cancer Institute; ClinicalTrials.gov number, NCT00003830.) PMID:21247310

  10. Interleukin-28B polymorphisms and interferon gamma inducible protein-10 serum levels in seronegative occult hepatitis C virus infection.

    PubMed

    Bartolomé, Javier; Castillo, Inmaculada; Quiroga, Juan Antonio; Carreño, Vicente

    2016-02-01

    Polymorphisms upstream interleukin (IL)-28B gene and serum levels of interferon gamma inducible protein-10 (IP-10) are associated with spontaneous and treatment-induced hepatitis C virus (HCV) clearance. Patients with seronegative occult HCV infection are anti-HCV and serum HCV-RNA negative but have viral RNA in liver and abnormal values of liver enzymes. We examined if the rs12979860 polymorphism of IL-28B and serum IP-10 levels differ between chronic and seronegative occult CV infection. IL-28B polymorphism was determined with allele specific TaqMan probes in total DNA isolated from peripheral blood mononuclear cells and IP-10 by an enzyme-linked immunosorbent assay in serum from 99 patients with seronegative occult HCV infection and 130 untreated patients with chronic hepatitis C. IL-28B genotypes were also determined in 54 healthy volunteers. Prevalence of the IL-28B CC genotype was significantly higher in seronegative occult HCV infection (52/99; 52.5%) than in chronic hepatitis C (32/130; 24.6%, P < 0.0001) or healthy controls (19/54: 32.5%, P = 0.039). Among patients with seronegative occult HCV infection, HCV-RNA load in liver was significantly lower in those with the IL-28B CC genotype than in those with CT + TT genotypes (2.8 × 10(5)  ± 5.8 × 10(4) vs. 4.1 × 10(5)  ± 5.9 × 10(4)  copies/μg of total RNA respectively; P = 0.023). Mean serum IP-10 levels were significantly lower in patients with seronegative occult HCV infection than in patients with chronic hepatitis C (160.8 ± 17.9 vs. 288.7 ± 13.3 pg/ml respectively; P < 0.0001). These findings suggest that the host immune response plays an important role in seronegative occult HCV infection in comparison with chronic hepatitis C. © 2015 Wiley Periodicals, Inc.

  11. Results of Observations of Occultations of Stars by Main-Belt and Trojan Asteroids, and the Promise of Gaia

    NASA Astrophysics Data System (ADS)

    Dunham, David W.; Herald, David Russell; Preston, Steven; Loader, Brian; Bixby Dunham, Joan

    2016-10-01

    For 40 years, the sizes and shapes of scores of asteroids have been determined from observations of asteroidal occultations, and many hundreds of high-precision positions of the asteroids relative to stars have been measured. Earlier this year, the 3000th observation of an asteroidal occultation was documented. Some of the first evidence for satellites of asteroids was obtained from the early efforts; now, the orbits and sizes of some satellites discovered by other means have been refined from occultation observations. Also, several close binary stars have been discovered, and the angular diameters of some stars have been measured from analysis of these observations. The International Occultation Timing Association (IOTA) coordinates this activity worldwide, from predicting and publicizing the events, to accurately timing the occultations from as many stations as possible, and publishing and archiving the observations. The first observations were timed visually, but now nearly all observations are either video-recorded, or recorded with CCD drift scans, allowing small magnitude-drop events to be recorded, and resulting in more consistent results. Techniques have been developed allowing one or two observers to set up multiple stations with small telescopes, video cameras, and timers, thereby recording many chords, even across a whole asteroid; some examples will be shown.Later this year, the first release of Gaia data will allow us to greatly improve the vast star catalog that we use for both predicting and analyzing these events. Although the first asteroidal data will wait until the 4th Gaia release, before that, we can greatly improve the orbits of asteroids that have occulted 3 or more stars in the past so that we can start computing the paths of future occultations by them to few km accuracy. In a couple of years, we'll be able to realistically predict one to two orders of magnitude more events than we can now, allowing efforts to be concentrated on smaller objects of the highest scientific interest, including some comets.

  12. [Relationship between salivary occult blood and level of volatile sulphur compounds in oral cavity].

    PubMed

    An, Yue-bang; He, Lu; Meng, Huan-xin; Liu, Ting-ting; Liu, Jian

    2010-07-01

    To observe the change of the salivary occult blood after periodontal mechanical therapy, and to assess the correlations between salivary occult blood and the level of volatile sulphur compounds (VSC) in oral cavity, periodontal clinical parameters, respectively. Fifty patients with gingivititis, mild or moderate periodontitis were included. The level of VSC were measured by Halimeter(®) and salivary occult blood was tested by Perioscreen(®) before periodontal examination. Then full mouth plaque index (PLI), probing depth (PD), bleeding index (BI) were charted. Attachment loss (AL) of the Ramfjörd teeth were recorded lastly. Intensive periodontal mechanical therapy was conducted including oral hygiene instruction, scaling and root planing (SRP). Four weeks after SRP, the same examinations were repeated. Salivary occult blood was significantly correlated with BI (r = 0.294) and PLI (r = 0.308) before periodontal therapy (P < 0.01), and also significantly correlated with VSC level (r = 0.386), PLI (r = 0.456), BI (r = 0.352), AL (r = 0.325) after therapy (P < 0.05). The improvement of VSC level [211.0 (111.0 - 389.5) × 10⁻⁹ vs 100.0 (46.3 - 165.3) × 10⁻⁹], the clinical periodontal parameters including PLI [(1.3 ± 1.0) vs (0.4 ± 0.6)], PD [(3.7 ± 1.5) mm vs (2.7 ± 0.9) mm], BI [(1.8 ± 1.2) vs (0.4 ± 0.7)] and AL [(1.0 ± 1.1) mm vs (0.1 ± 0.5) mm after the treatment was statistically significant (P < 0.001). However, standing on the viewpoint of salivary occult blood changes from positive before therapy to negative after therapy, only 80% (40/50) individuals were totally cured. VSC level in oral cavity and periodontal clinical parameters significantly decreased (P < 0.001) following the trends from strong positive, weak positive, to negative results of salivary occult blood test. Salivary occult blood was correlated with VSC level in oral cavity of periodontal treated patients. It may be an objective parameter to evaluate the gingival inflammation and the efficacy of the periodontal therapy at individual level.

  13. Studying Big Planets with Small Telescopes: The z'-Band Occultation of WASP-19b Observed with EulerCam and TRAPPIST

    NASA Astrophysics Data System (ADS)

    Lendl, Monika; Gillon, Michael; Queloz, Didier

    2013-04-01

    Transiting planets have opened up a window to the detailed study of extrasolar planets as their orbital orientation allows the measurement of the planet/star radius and flux ratios. From the observation of planetary transits and occultations at different wavelengths we can gain insights into the planets temperature, atmospheric composition, energy redistribution and albedo. In order to contribute to the characterization of planetary atmospheres, it is necessary to obtain high precision measurements of planetary transits and occultations as the signals of interest have amplitudes of typically 100 ppm. We use two dedicated instruments, EulerCam at the 1.2m Euler-Swiss telescope and the 0.6m TRAPPIST telescope for the in-depth study of transiting planets through time resolution photometry. While single lightcurves from 1m class telescopes typically reach photometric precisions of around 1mmag, we obtain very high accuracy on the transit and occultation shape by not relying on single observations but collecting larger samples of lightcurves. In this framework, we have performed an extensive observing campaign on the Hot Jupiter WASP-19b collecting over 60 hours of observations with EulerCam and TRAPPIST. The data cover 14 transits and 10 occultations of WASP-19b. We demonstrate how the attainable photometric precision and accuracy of the derived parameters can be greatly improved by combining an increasing number of lightcurves as instrumental and stellar effects can be identified and accounted for. We report the detection of the occultation of WASP-19b in the z'-band. This measurement is one of only a handful of exoplanet occultations detected from the ground at wavelengths shorter than 1μm , and so far the only one obtained from the ground using 1m class telescopes. Our value adds to an ensemble of occultation measurements for this planet, and is indicative of an Oxygen-dominated chemistry. From our sample of transits, we measure the transit depth to a precision of better than 1% in the r', I+z' and z' bands.

  14. Waiting for Shadows from the Distant Solar System

    NASA Astrophysics Data System (ADS)

    Kohler, Susanna

    2016-03-01

    How can we hope to measure the hundreds of thousands of objects in our distant solar system? A team of astronomers is harnessing citizen science to begin to tackle this problem!A light curve from an occultation collected by a RECON site in Quincy, California. As the objects shadow passes, the background stars light dims. [RECON/Charley Arrowsmith (Feather River College)]Occultation InformationEstimates currently place the number of Kuiper belt objects larger than 100 km across at over 100,000. Knowing the sizes and characteristics of these objects is important for understanding the composition of the outer solar system and constraining models of the solar systems formation and evolution.Unfortunately, measuring small, dim bodies at large distances is incredibly difficult! One of the best ways to obtain the sizes of these objects is to watch as they occult a distant star. Timing the object as it passes across the face of the star can give us a good measure of its size and shape, when observed from multiple stations in the path of the shadow.An Extended NetworkOccultations by nearby objects (like main-belt asteroids) can be predicted fairly accurately, but those by trans-Neptunian objects are much more poorly constrained. Only ~900 trans-Neptunian objects have approximately known paths, and occultation-shadow predictions for these objects are often only accurate to ~1000km on the Earths surface. So how can we ensure that theres a telescope in the right location, ready to observe when an occultation occurs?Map of the 56 RECON sites distributed over 2000 km in the western United States. [Buie et al. 2016]The simplest answer is to set up a huge network of observing stations, and wait for the shadows to come to the network. With this approach, even if the predicted path isnt precisely known, some of the stations will still observe the occultation.Due to the number of stations needed, this project lends itself perfectly to citizen science. In a recently published paper by Marc Buie (Southwest Research Institute) and John Keller (California Polytechnic State University), the team describes the Research and Education Collaborative Occultation Network (RECON).RECON of Distant ObjectsRECON consists of 56 communities in the western United States that have each been armed with a telescope, camera, and timing device. The observing groups include teachers and their students, amateur astronomers, and other community members, and telescopes are primarily located at schools.Because the shadows from occultations generally travel from east to west, the communities are based in a roughly north-south network spanning 2000 km. Theyre spaced no more than 50 km apart, providing enough coverage to obtain sizes for 100-km objects crossing the baseline.RECON is a great example of how citizen science can be used to advance astronomy. The project reached full operating status in April 2015, and it has already conducted two official observing campaigns of trans-Neptunian objects, as well as roughly 30 additional campaigns, including training runs and local projects. The team is now publishing some of its first results in an upcoming paper, so keep an eye out for future publications to find out what theyve learned!BonusCheck out this awesome video of an asteroid occulting a star, as observed by a RECON system. The grey field shows the actual video image collected by one of the RECON cameras, in which one of the two visible stars (the one on the right) is occulted. The asteroid itself is too dim for us to see. The inset at the top left shows the light curve collected during the occultation, and the upper right-hand corner shows an animation of the asteroid as it occults the star. [RECON]CitationMarc W. Buie and John M. Keller 2016 AJ 151 73. doi:10.3847/0004-6256/151/3/73

  15. The Occult: Diabolica to Alchemists

    ERIC Educational Resources Information Center

    Delaney, Oliver J.

    1971-01-01

    The 91 items in this bibliography deal with works of occult science. The material is subdivided into biographies, dictionaries, encyclopedias, handbooks, noteworthy histories, indices, annuals, and a few miscellany works with treatises. (95 references) (Author)

  16. BATSE imaging survey of the Galactic plane

    NASA Technical Reports Server (NTRS)

    Grindlay, J. E.; Barret, D.; Bloser, P. F.; Zhang, S. N.; Robinson, C.; Harmon, B. A.

    1997-01-01

    The burst and transient source experiment (BATSE) onboard the Compton Gamma Ray Observatory (CGRO) provides all sky monitoring capability, occultation analysis and occultation imaging which enables new and fainter sources to be searched for in relatively crowded fields. The occultation imaging technique is used in combination with an automated BATSE image scanner, allowing an analysis of large data sets of occultation images for detections of candidate sources and for the construction of source catalogs and data bases. This automated image scanner system is being tested on archival data in order to optimize the search and detection thresholds. The image search system, its calibration results and preliminary survey results on archival data are reported on. The aim of the survey is to identify a complete sample of black hole candidates in the galaxy and constrain the number of black hole systems and neutron star systems.

  17. Testing for Occult Heartworm Infection

    PubMed Central

    Stogdale, L.

    1984-01-01

    Heartworm infection in dogs is endemic in southern Ontario but occurs only sporadically throughout the remainder of Canada. The disease may either be associated with microfilariae in the patient's blood, a patent infection, or it may be occult. This paper describes a case of occult dirofilariasis in a dog, with emphasis on the diagnosis. A patent infection could be missed if the clinician tests an insufficient amount of blood. He should perform multiple concentration tests using either the modified Knott's technique or a filtration method. Occult infections occur in prepatent or unisexual infections, when the worms become sterile following therapy, or when the host produces antibodies that result in the destruction of the microfilariae. The recent release of a kit which detects the presence of antibodies to the adult heartworms now enables veterinarians to make an accurate diagnosis in the vast majority of dogs. PMID:17422386

  18. Exploring the Solar System using stellar occultations

    NASA Astrophysics Data System (ADS)

    Sicardy, Bruno

    2018-04-01

    Stellar occultations by solar system objects allow kilometric accuracy, permit the detection of tenuous atmospheres (at nbar level), and the discovery of rings. The main limitation was the prediction accuracy, typically 40 mas, corresponding to about 1,000 km projected at the body. This lead to large time dedicated to astrometry, tedious logistical issues, and more often than not, mere miss of the event. The Gaia catalog, with sub-mas accuracy, hugely improves both the star positions, resulting in achievable accuracies of about 1 mas for the shadow track on Earth. This permits much more carefully planned campaigns, with success rate approaching 100%, weather permitting. Scientific perspectives are presented, e.g. central flashes caused by Plutos atmosphere revealing hazes and winds near its surface, grazing occultations showing topographic features, occultations by Chariklos rings unveiling dynamical features such as proper mode ``breathing''.

  19. First results from the ionospheric radio occultations of Saturn by the Cassini spacecraft

    NASA Astrophysics Data System (ADS)

    Nagy, Andrew F.; Kliore, Arvydas J.; Marouf, Essam; French, Richard; Flasar, Michael; Rappaport, Nicole J.; Anabtawi, Aseel; Asmar, Sami W.; Johnston, Douglas; Barbinis, Elias; Goltz, Gene; Fleischman, Don

    2006-06-01

    The first set of near-equatorial occultations of the Saturn ionosphere was obtained by the Cassini spacecraft between May and September of 2005. The occultations occurred at near-equatorial latitudes, between 10°N and 10°S, at solar zenith angles from about 84° to 96°. The entry observations correspond to dusk conditions and the exit ones to dawn. An initial look at the data indicates that the average peak densities are lower and the peak altitude higher at dawn than at dusk, possibly the result of ionospheric decay during the night hours. There are also significant differences between individual dawn and dusk occultations; the initial thought is that this variation must be connected to changes in the water inflow into the upper atmosphere and/or variations in the particle impact ionization rates.

  20. Occult infection related hepatitis B surface antigen variants showing lowered secretion capacity

    PubMed Central

    Kim, Hong; Lee, Seoung-Ae; Won, You-Sub; Lee, HyunJoo; Kim, Bum-Joon

    2015-01-01

    AIM: To elucidate the molecular mechanisms underlying hepatitis B virus (HBV) occult infection of genotype C. METHODS: A total of 10 types of hepatitis B surface antigen (HBsAg) variants from a Korean occult cohort were used. After a complete HBV genome plasmid mutated such that it does not express HBsAg and plasmid encoding, each HBsAg variant was transiently co-transfected into HuH-7 cells. The secretion capacity and intracellular expression of the HBV virions and HBsAgs in their respective variants were analyzed using real-time quantitative polymerase chain reaction assays and commercial HBsAg enzyme-linked immunosorbent assays, respectively. RESULTS: All variants exhibited lower levels of HBsAg secretion into the medium compared with the wild type. In particular, in eight of the ten variants, very low levels of HBsAg secretion that were similar to the negative control were detected. In contrast, most variants (9/10) exhibited normal virion secretion capacities comparable with, or even higher than, the wild type. This provided new insight into the intrinsic nature of occult HBV infection, which leads to HBsAg sero-negativeness but has horizontal infectivity. Furthermore, most variants generated higher reactive oxidative species production than the wild type. This finding provides potential links between occult HBV infection and liver disease progression. CONCLUSION: The presently obtained data indicate that deficiency in the secretion capacity of HBsAg variants may have a pivotal function in the occult infections of HBV genotype C. PMID:25684944

  1. Predictive Power of Distal Radial Metaphyseal Tenderness for Diagnosing Occult Fracture.

    PubMed

    Glickel, Steven Z; Hinojosa, Lauren; Eden, Claire M; Balutis, Elaine; Barron, O Alton; Catalano, Louis W

    2017-10-01

    To correlate the physical examination finding of distal radial metaphyseal tenderness with plain radiographic and magnetic resonance imaging after acute wrist injury to diagnose occult distal radius fractures. We hypothesized that persistent distal radial metaphyseal tenderness 2 weeks after acute injuries is predictive of an occult fracture. Twenty-nine adult patients presented, after acute trauma, with distal radial metaphyseal tenderness and initial plain radiographs and/or fluoroscopic images that did not show a distal radius fracture. Patients were reevaluated clinically and radiographically at approximately 2 weeks after initial presentation. Patients with persistent distal radial tenderness and negative radiographs underwent magnetic resonance imaging to definitively diagnose an occult distal radius fracture. We calculated the sensitivity and positive predictive value for persistent distal radial metaphyseal tenderness using a 95% confidence interval and standard formulas. Both radiographs and magnetic resonance imaging were used as our endpoint diagnosis for a distal radius fracture. We diagnosed 28 occult distal radius fractures, 8 by follow-up radiograph and 20 by magnetic resonance imaging. The positive predictive value for patients who completed the protocol was 96%. One patient who did not have an occult distal radius fracture had a fracture of the ulnar styloid. Tenderness of the distal radial metaphysis after wrist injury is strongly suggestive of a distal radius fracture despite both normal plain radiographs and fluoroscopic images. Diagnostic III. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Optimization of the occulter for the Solar Orbiter/METIS coronagraph

    NASA Astrophysics Data System (ADS)

    Landini, Federico; Vivès, Sébastien; Romoli, Marco; Guillon, Christophe; Pancrazzi, Maurizio; Escolle, Clement; Focardi, Mauro; Antonucci, Ester; Fineschi, Silvano; Naletto, Giampiero; Nicolini, Gianalfredo; Nicolosi, Piergiorgio; Spadaro, Daniele

    2012-09-01

    METIS (Multi Element Telescope for Imaging and Spectroscopy investigation), selected to fly aboard the Solar Orbiter ESA/NASA mission, is conceived to perform imaging (in visible, UV and EUV) and spectroscopy (in EUV) of the solar corona, by means of an integrated instrument suite located on a single optical bench and sharing the same aperture on the satellite heat shield. As every coronagraph, METIS is highly demanding in terms of stray light suppression. Coronagraphs history teaches that a particular attention must be dedicated to the occulter optimization. The METIS occulting system is of particular interest due to its innovative concept. In order to meet the strict thermal requirements of Solar Orbiter, METIS optical design has been optimized by moving the entrance pupil at the level of the external occulter on the S/C thermal shield, thus reducing the size of the external aperture. The scheme is based on an inverted external-occulter (IEO). The IEO consists of a circular aperture on the Solar Orbiter thermal shield. A spherical mirror rejects back the disk-light through the IEO. A breadboard of the occulting assembly (BOA) has been manufactured in order to perform stray light tests in front of two solar simulators (in Marseille, France and in Torino, Italy). A first measurement campaign has been carried on at the Laboratoire d'Astrophysique de Marseille. In this paper we describe the BOA design, the laboratory set-up and the preliminary results.

  3. Spatial patterns of whole brain grey and white matter injury in patients with occult spastic diplegic cerebral palsy.

    PubMed

    Mu, Xuetao; Nie, Binbin; Wang, Hong; Duan, Shaofeng; Zhang, Zan; Dai, Guanghui; Ma, Qiaozhi; Shan, Baoci; Ma, Lin

    2014-01-01

    Spastic diplegic cerebral palsy (SDCP) is a common type of cerebral palsy (CP), which presents as a group of motor-impairment syndromes. Previous conventional MRI studies have reported abnormal structural changes in SDCP, such as periventricular leucomalacia. However, there are roughly 27.8% SDCP patients presenting normal appearance in conventional MRI, which were considered as occult SDCP. In this study, sixteen patients with occult SDCP and 16 age- and sex-matched healthy control subjects were collected and the data were acquired on a 3T MR system. We applied voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) analysis to investigate whole brain grey and white matter injury in occult SDCP. By using VBM method, the grey matter volume reduction was revealed in the bilateral basal ganglia regions, thalamus, insula, and left cerebral peduncle, whereas the white matter atrophy was found to be located in the posterior part of corpus callosum and right posterior corona radiata in the occult SDCP patients. By using TBSS, reduced fractional anisotropy (FA) values were detected in multiple white matter regions, including bilateral white matter tracts in prefrontal lobe, temporal lobe, internal and external capsule, corpus callosum, cingulum, thalamus, brainstem and cerebellum. Additionally, several regions of white matter tracts injury were found to be significantly correlated with motor dysfunction. These results collectively revealed the spatial patterns of whole brain grey and white matter injury in occult SDCP.

  4. Pluto's Radius

    NASA Astrophysics Data System (ADS)

    Young, Eliot F.; Young, L. A.; Buie, M.

    2007-10-01

    The size of Pluto has been difficult to measure. Stellar occultations by Pluto have not yet probed altitudes lower than 1198 km, assuming the clear atmosphere model of Elliot, Person and Qu (2003). Differential refraction by Pluto's atmosphere attenuates the light from an occulted star to a level that is indistinguishable from the zero-level baseline long before Pluto's solid surface is a factor. Since Charon has no detectable atmosphere, its radius was well determined from a stellar occultation in 2005 (Gulbis et al. 2006, Sicardy et al. 2006). Combined with the mutual event photometry (Charon transited Pluto every 6.38 days between 1986 through 1992) - for which differential refraction is a negligible effect - the well-known radius of Charon translates into a more accurate radius for Pluto's solid surface. Our preliminary solid radius estimate for Pluto is 1161 km. We will discuss error bars and the correlations of this determination with Pluto albedo maps. We will also discuss the implications for Pluto's thermal profile, surface temperature and pressure, and constraints on the presence of a haze layer. This work is funded by NASA's Planetary Astronomy program. References Elliot, J.L., Person, M.J., & Qu, S. 2003, "Analysis of Stellar Occultation Data. II. Inversion, with Application to Pluto and Triton." AJ, 126, 1041. Gulbis, A.A.S. et al. 2006, "Charon's radius and atmospheric constraints from observations of a stellar occultation." Nature, 49, 48. Sicardy, B. et al. 2006, "Charon's size and an upper limit on its atmosphere from a stellar occultation." Nature, 49, 52.

  5. Association of maximum standardized uptake value with occult mediastinal lymph node metastases in cN0 non-small cell lung cancer.

    PubMed

    Lin, Jun-Tao; Yang, Xue-Ning; Zhong, Wen-Zhao; Liao, Ri-Qiang; Dong, Song; Nie, Qiang; Weng, Si-Xian; Fang, Xiao-Jing; Zheng, Jun-Yi; Wu, Yi-Long

    2016-11-01

    The management of non-small cell lung cancer (NSCLC) relies on the tumour-node-metastasis (TNM) stage, and the treatment regimen differs based on the N status. Positron emission tomography-computed tomography (PET-CT) has emerged as a powerful imaging tool for the detection of various cancers with a relatively low false-negative rate. We explored predictors to identify false-negative N2 disease in PET-CT. A total of 284 consecutive cN0 patients with peripheral NSCLC who underwent PET-CT scans followed by curative intent resections were enrolled as a training set to identify predictors of occult N2 metastases by multivariable analysis. The accuracy and cut-off values for the predictors were calculated using a receiver operating characteristic curve. Clinical and pathological data were analysed retrospectively. An additional 151 patients were collected as a test set to validate the results, including the occult N2 rate and accuracy. In total, 8.5% (24/284) PET-CT-diagnosed N0 NSCLC cases had pathologically diagnosed N2 metastases. The SUV max of the primary tumour was a unique independent risk factor for occult N2 NSCLC [P = 0.003, 95% confidence interval = 0.81-0.96, odds ratio (OR) = 0.88]. Occult N2 metastases occurred more frequently in the subcarinal (16/24) and right lower paratracheal lymph nodes (12/24). Accordingly, we divided the patients into two groups by SUV max : the occult N2 rates in the SUV max of <2.6 and SUV max of ≥2.6 groups were 1.0% (1/100) and 12.5% (23/184), respectively (P = 0.001). In the test set, the occult N2 incidence rate was 9.3% (14/151), with the highest rates occurring in the subcarinal (9/14) and right lower paratracheal lymph nodes (6/14). In the two groups defined by SUV max , the occult N2 rates were 4% (2/50) and 11.9% (12/101), respectively. The SUV max of the primary tumour was an independent risk factor for occult N2 metastases in NSCLC patients diagnosed as clinical N0 by PET-CT. SUV max of ≥2.6 of the primary tumour may indicate the risk of N2 metastases, and invasive mediastinal staging techniques or comprehensive therapy should not be ignored in these patients. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. On Combining Thermal-Infrared and Radio-Occultation Data of Saturn's Atmosphere

    NASA Technical Reports Server (NTRS)

    Flasar, F. M.; Schinder, P. J.; Conrath, B. J.

    2008-01-01

    Radio-occultation and thermal-infrared measurements are complementary investigations for sounding planetary atmospheres. The vertical resolution afforded by radio occultations is typically approximately 1 km or better, whereas that from infrared sounding is often comparable to a scale height. On the other hand, an instrument like CIRS can easily generate global maps of temperature and composition, whereas occultation soundings are usually distributed more sparsely. The starting point for radio-occultation inversions is determining the residual Doppler-shifted frequency, that is the shift in frequency from what it would be in the absence of the atmosphere. Hence the positions and relative velocities of the spacecraft, target atmosphere, and DSN receiving station must be known to high accuracy. It is not surprising that the inversions can be susceptible to sources of systematic errors. Stratospheric temperature profiles on Titan retrieved from Cassini radio occultations were found to be very susceptible to errors in the reconstructed spacecraft velocities (approximately equal to 1 mm/s). Here the ability to adjust the spacecraft ephemeris so that the profiles matched those retrieved from CIRS limb sounding proved to be critical in mitigating this error. A similar procedure can be used for Saturn, although the sensitivity of its retrieved profiles to this type of error seems to be smaller. One issue that has appeared in inverting the Cassini occultations by Saturn is the uncertainty in its equatorial bulge, that is, the shape in its iso-density surfaces at low latitudes. Typically one approximates that surface as a geopotential surface by assuming a barotropic atmosphere. However, the recent controversy in the equatorial winds, i.e., whether they changed between the Voyager (1981) era and later (after 1996) epochs of Cassini and some Hubble observations, has made it difficult to know the exact shape of the surface, and it leads to uncertainties in the retrieved temperature profiles of one to a few kelvins. This propagates into errors in the retrieved helium abundance, which makes use of thermal-infrared spectra and synthetic spectra computed with retrieved radio-occultation temperature profiles. The highest abundances are retrieved with the faster Voyager-era winds, but even these abundances are somewhat smaller than those retrieved from the thermal-infrared data alone (albeit with larger formal errors). The helium abundance determination is most sensitive to temperatures in the upper troposphere. Further progress may include matching the radio-occultation profiles with those from CIRS limb sounding in the upper stratosphere.

  7. Cassini First Diametric Radio Occultation of Saturn's Rings

    NASA Astrophysics Data System (ADS)

    Marouf, E.; French, R.; Rappaport, N.; Kliore, A.; Flasar, M.; Nagy, A.; Ambrosini, R.; McGhee, C.; Schinder, P.; Anabtawi, A.; Barbinis, E.; Goltz, G.; Thomson, F.; Wong, K.

    2005-05-01

    We present preliminary results expected from the first planned Cassini radio occultation observation of Saturn's rings, to be conducted on May 3rd, 2005. The path of Cassini as seen from Earth (the occultation track) has been designed to cross the rings from the west to the east ansa almost diametrically, allowing for occultation of all major ring features at two widely separated longitudes (about 180 deg apart). The duration of the geometric occultation is about 1.5 hours on each side. During the occultation, Cassini transmits through the rings three coherent monochromatic radio signals of wavelength 0.94, 3.6, and 13 cm (Ka-, X-, and S-band respectively), a capability unique to Cassini. The perturbed signals received at the Earth are recorded at the NASA DSN complexes at Goldstone and Canberra. Both direct and forward-scattered components of the signal may be identified in spectrograms of the received signals. The time history of the extinction of the direct signal is expected to yield high-spatial-resolution optical depth and phase shift profiles of ring structure. The timing of the occultation was optimized to allow probing the rings when the ring-opening-angle B (the angle between the line-of-sight and the ring plane) is relatively large (B = 23 deg), hence maximizing chances of measuring for the first time the structure of the relatively optically thick Ring B. In a similar experiment by Voyager in 1980, excessive signal attenuation along the long path within the nearly closed rings (B = 5.9 deg) limited the utility of the observations in relatively thick ring regions, in particular the main Ring B. For the Cassini optimized occultation geometry, a large B, slow radial velocity along the occultation track, and much improved phase stability of the reference ultrastable oscillator (USO) on board Cassini combine to promise achievable radial resolution approaching 100 m over a good fraction of the rings. Measurement of the amplitude and phase of the diffracted signal enables reconstruction of the observations to remove diffraction effects. Reliable high resolution profiling of ring structure at multiple ring longitudes is at the heart of investigating ring kinematics and dynamics, a major scientific objective of this experiment. In addition, observations of the scattered signal combined with measurements of the differential extinction of the three radio signals are expected to yield complementary information about ring physical properties, including particle size distribution and thickness, another major scientific objective.

  8. First Ionospheric Results From the MAVEN Radio Occultation Science Experiment (ROSE)

    NASA Astrophysics Data System (ADS)

    Withers, Paul; Felici, M.; Mendillo, M.; Moore, L.; Narvaez, C.; Vogt, M. F.; Jakosky, B. M.

    2018-05-01

    Radio occultation observations of the ionosphere of Mars can span the full vertical extent of the ionosphere, in contrast to in situ measurements that rarely sample the main region of the ionosphere. However, most existing radio occultation electron density profiles from Mars were acquired without clear context for the solar forcing or magnetospheric conditions, which presents challenges for the interpretation of these profiles. Here we present 48 ionospheric electron density profiles acquired by the Mars Atmosphere and Volatile EvolutioN mission (MAVEN) Radio Occultation Science Experiment (ROSE) from 5 July 2016 to 27 June 2017 at solar zenith angles of 54° to 101°. Latitude coverage is excellent, and comprehensive context for the interpretation of these profiles is provided by other MAVEN instruments. The profiles show a 9-km increase in ionospheric peak altitude in January 2017 that is associated with a lower atmospheric dust storm, variations in electron densities in the M1 layer that cannot be explained by variations in the solar soft X-ray flux, and topside electron densities that are larger in strongly magnetized regions than in weakly magnetized regions. MAVEN Radio Occultation Science Experiment electron density profiles are publicly available on the NASA Planetary Data System.

  9. Occultations of Astrophysical Radio Sources as Probes of Planetary Environments: A Case Study of Jupiter and Possible Applications to Exoplanets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Withers, Paul; Vogt, Marissa F.

    Properties of planetary atmospheres, ionospheres, and magnetospheres are difficult to measure from Earth. Radio occultations are a common method for measuring these properties, but they traditionally rely on radio transmissions from a spacecraft near the planet. Here, we explore whether occultations of radio emissions from a distant astrophysical radio source can be used to measure magnetic field strength, plasma density, and neutral density around planets. In a theoretical case study of Jupiter, we find that significant changes in polarization angle due to Faraday rotation occur for radio signals that pass within 10 Jupiter radii of the planet and that significantmore » changes in frequency and power occur from radio signals that pass through the neutral atmosphere. There are sufficient candidate radio sources, such as pulsars, active galactic nuclei, and masers, that occultations are likely to occur at least once per year. For pulsars, time delays in the arrival of their emitted pulses can be used to measure plasma density. Exoplanets, whose physical properties are very challenging to observe, may also occult distant astrophysical radio sources, such as their parent stars.« less

  10. Radiologically occult pulmonary lymphangitic carcinomatosis detected by /sup 67/Ga-citrate scintiscan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Band, P.R.; Lentle, B.C.; Amy, R.

    1976-10-01

    The use of gallium-67-citrate scintiscanning in the diagnosis of radiologically occult lung metastases is illustrated. The technique was used to demonstrate pulmonary lymphangitic carcinomatosis metastatic from breast cancer. (ERB)

  11. McDonald's and the Occult.

    ERIC Educational Resources Information Center

    Singer, Barry

    1979-01-01

    Discusses "occult" and "paranormal" literature which is often mistaken for nonfiction. Suggests that most publishers are unwilling to publish scientific perspectives on the paranormal because such writings would be unmarketable. Journal availability: see SO 507 190. (KC)

  12. Detection of occult abscesses with /sup 111/In-labeled leukocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, W.R.; Gurevich, N.; Goris, M.L.

    1979-07-01

    Clinicians are frequently faced with the problem of a patient in whom they suspect an occult abscess. In such a situation, there may be no clinical signs to localize the site of the abscess and often extensive investigations do not provide additional useful information. This report illustrates the efficacy of autologous leukocytes labeled with /sup 111/In oxine in detecting the site and extent of occult abscesses in two patients. The technique of in vitro lebeling of leukocytes is simple and has been mastered by all of our nuclear medicine technologists.

  13. Forthcoming Occultations of Astrometric Radio Sources by Planets

    NASA Technical Reports Server (NTRS)

    L'vov, Victor; Malkin, Zinovy; Tsekmeister, Svetlana

    2010-01-01

    Astrometric observations of radio source occultations by solar system bodies may be of large interest for testing gravity theories, dynamical astronomy, and planetary physics. In this paper, we present an updated list of the occultations of astrometric radio sources by planets expected in the coming years. Such events, like solar eclipses, generally speaking can only be observed in a limited region. A map of the shadow path is provided for the events that will occurr in regions with several VLBI stations and hence will be the most interesting for radio astronomy experiments.

  14. Observations of the Occultation of Mars by the Moon on July 6, 2014

    NASA Astrophysics Data System (ADS)

    Ricra, J. L.; Pajuelo, M. V.; Berrocal, D. R.; Torre, S. E.

    2015-10-01

    We present the results of the observation of the occultation of Mars by the Moon on July 6, 2014. Observations were made from the AFARI Astronomical Observatory, in the town of Tarma, Peru. A Celestron 8 telescope with a camera WATEC 120N (GPS time inserted) were used. Time measurements for the first and second contact were obtained by analyzing the variation of the flux of Mars using the software LiMovie and two different methods of calculation. The measurements obtained were reported to the International Occultation Timing Association (IOTA).

  15. The Thermal Structure of Triton's Atmosphere: Results from the 1993 and 1995 Occultations

    NASA Astrophysics Data System (ADS)

    Olkin, C. B.; Elliot, J. L.; Hammel, H. B.; Cooray, A. R.; McDonald, S. W.; Foust, J. A.; Bosh, A. S.; Buie, M. W.; Millis, R. L.; Wasserman, L. H.; Dunham, E. W.; Young, L. A.; Howell, R. R.; Hubbard, W. B.; Hill, R.; Marcialis, R. L.; McDonald, J. S.; Rank, D. M.; Holbrook, J. C.; Reitsema, H. J.

    1997-09-01

    This paper presents new results about Triton's atmospheric structure from the analysis of all ground-based stellar occultation data recorded to date, including one single-chord occultation recorded on 1993 July 10 and nine occultation lightcurves from the double-star event on 1995 August 14. These stellar occultation observations made both in the visible and in the infrared have good spatial coverage of Triton, including the first Triton central-flash observations, and are the first data to probe the altitude level 20-100 km on Triton. The small-planet lightcurve model of J. L. Elliot and L. A. Young (1992,Astron. J.103,991-1015) was generalized to include stellar flux refracted by the far limb, and then fitted to the data. Values of the pressure, derived from separate immersion and emersion chords, show no significant trends with latitude, indicating that Triton's atmosphere is spherically symmetric at ∼50-km altitude to within the error of the measurements; however, asymmetry observed in the central flash indicates the atmosphere is not homogeneous at the lowest levels probed (∼20-km altitude). From the average of the 1995 occultation data, the equivalent-isothermal temperature of the atmosphere is 47 ± 1 K and the atmospheric pressure at 1400-km radius (∼50-km altitude) is 1.4 ± 0.1 μbar. Both of these are not consistent with a model based on Voyager UVS and RSS observations in 1989 (D. F. Strobel, X. Zhu, M. E. Summers, and M. H. Stevens, 1996,Icarus120,266-289). The atmospheric temperature from the occultation is 5 K colder than that predicted by the model and the observed pressure is a factor of 1.8 greater than the model. In our opinion, the disagreement in temperature and pressure is probably due to modeling problems at the microbar level, since measurements at this level have not previously been made. Alternatively, the difference could be due to seasonal change in Triton's atmospheric structure.

  16. Shape and Size of Patroclus and Menoetius from a Stellar Occultation

    NASA Astrophysics Data System (ADS)

    Buie, Marc W.; Olkin, Catherine B.; Merline, William J.; Timerson, Brad; Herald, Dave; Owen, William M.; Abramson, Harry B.; Abramson, Katherine J.; Breit, Derek C.; Caton, D. B.; Conard, Steve J.; Croom, Mark A.; Dunford, R. W.; Dunford, J. A.; Dunham, David W.; Ellington, Chad K.; Liu, Yanzhe; Maley, Paul D.; Olsen, Aart M.; Royer, Ronald; Scheck, Andrew E.; Sherrod, Clay; Sherrod, Lowell; Swift, Theodore J.; Taylor, Lawrence W.; Venable, Roger

    2014-11-01

    We will present results of a stellar occultation by the Jupiter Trojan asteroid, Patroclus and its nearly equal size moon, Menoetius. The occultation was observed widely across the United States on 2013 Oct 21 UT. Eleven sites out of 36 successfully recorded an occultation. Seven chords across Patroclus yielded a elliptical limb fit of 124.6 km by 98.2 km. There were six chords across Menoetius that yielded an elliptical limb fit of 117.2 km by 93.0 km. There were three sites that got chords on both objects. At the time of the occultation we measured a separation of 0.247 arcsec and a position angle for Menoetius of 265.7 deg measured eastward from J2000 North. More surprisingly, there were two sites that should have seen an occultation by Menoetius but instead never saw the star disappear. These two non-detections indicate the presence of a large void on the southern limb of the satellite. The observations are consistent with a large impact basin centered on the rotation pole. The depth of the projected crater profile is roughly 15 km, measured from the elliptical limb profile. The inferred diameter of the crater would be about 85 km. Combining this occultation data with previous lightcurve data, the axial ratios (ignoring the mass void) of both objects is 1.26:1.19:1 indicative of a mostly oblate ellipsoid with a slight asymmetry in its equatorial projection. These results are consistent with a fully tidally evolved system with the mass void or putative crater in a position consistent with principal axis rotation that is itself consistent with the largely oblate shape. Note: the location for IOTA listed in the affiliations is not correct (but was required to be entered) as there is no location for this global virtual organization. This research is funded, in part, by NSF AST-1212159.

  17. Occult diaphragmatic injuries caused by stab wounds.

    PubMed

    Leppäniemi, Ari; Haapiainen, Reijo

    2003-10-01

    Missed diaphragmatic perforation caused by penetrating trauma can lead to subsequent strangulation of a hollow viscus, which has prompted the use of invasive diagnostic procedures to exclude occult diaphragmatic injuries in asymptomatic, high-risk patients. The objective of this study was to determine the incidence of occult diaphragmatic injuries caused by stab wounds of the lower chest and upper abdomen, and to examine the natural history and consequences of missed diaphragmatic injuries. On the basis of patient data from two previous randomized studies from our institution, a retrospective analysis was performed on 97 patients treated for anterior stab wounds located between the nipple line, the umbilical level, and the posterior axillary lines not having indications for immediate surgical exploration. The patients were divided into two groups on the basis of their initial randomized management (open or laparoscopic exploration vs. expectant observation). In the exploration group (n = 47), four diaphragmatic injuries (9%) were detected (three left-sided and one right-sided). Excluding patients with associated injuries requiring surgical repair, the incidence of occult diaphragmatic injuries was 3 of 43 (7%). In the observation group (n = 50), there were two patients (4%) with delayed presentation of missed left-sided diaphragmatic injury 2 and 23 months later, respectively. Both injuries resulted from stab wounds of the left flank and presented with herniation of the stomach or small bowel and colon. The overall incidence of occult diaphragmatic injuries in left-sided thoracoabdominal stab wounds was 4 of 24 (17%), and was much lower after stab wounds of left epigastrium (0%), right lower chest (0%), and right epigastrium (4%). In asymptomatic patients with anterior or flank stab wounds of the lower chest or upper abdominal area, the risk of an occult diaphragmatic injury is approximately 7% which, if undetected, is associated with a high risk of subsequent hollow viscus herniation. Exclusion of an occult diaphragmatic injury with invasive diagnostic methods, such as laparoscopy or thoracoscopy, should be considered at least in left-sided stab wounds of the lower chest.

  18. Circulating Tumor Cells Predict Occult Metastatic Disease and Prognosis in Pancreatic Cancer.

    PubMed

    Court, Colin M; Ankeny, Jacob S; Sho, Shonan; Winograd, Paul; Hou, Shuang; Song, Min; Wainberg, Zev A; Girgis, Mark D; Graeber, Thomas G; Agopian, Vatche G; Tseng, Hsian-Rong; Tomlinson, James S

    2018-04-01

    Occult metastatic tumors, below imaging thresholds, are a limitation of staging systems that rely on cross-sectional imaging alone and are a cause of the routine understaging of pancreatic ductal adenocarcinomas (PDACs). We investigated circulating tumor cells (CTCs) as a preoperative predictor of occult metastatic disease and as a prognostic biomarker for PDAC patients. A total of 126 patients (100 with cancer, 26 with benign disease) were enrolled in our study and CTCs were identified and enumerated from 4 mL of venous blood using the microfluidic NanoVelcro assay. CTC enumeration was correlated with clinicopathologic variables and outcomes following both surgical and systemic therapies. CTCs were identified in 78% of PDAC patients and CTC counts correlated with increasing stage (ρ = 0.42, p < 0.001). Of the 53 patients taken for potentially curative surgery, 13 (24.5%) had occult metastatic disease intraoperatively. Patients with occult disease had significantly more CTCs than patients with local disease only (median 7 vs. 1 CTC, p < 0.0001). At a cut-off of three or more CTCs/4 mL, CTCs correctly identified patients with occult metastatic disease preoperatively (area under the receiver operating characteristic curve 0.82, 95% confidence interval (CI) 0.76-0.98, p < 0.0001). CTCs were a univariate predictor of recurrence-free survival following surgery [hazard ratio (HR) 2.36, 95% CI 1.17-4.78, p = 0.017], as well as an independent predictor of overall survival on multivariate analysis (HR 1.38, 95% CI 1.01-1.88, p = 0.040). CTCs show promise as a prognostic biomarker for PDAC patients at all stages of disease being treated both medically and surgically. Furthermore, CTCs demonstrate potential as a preoperative biomarker for identifying patients at high risk of occult metastatic disease.

  19. Risk of Ischemic and Hemorrhagic Strokes in Occult and Manifest Cancers.

    PubMed

    Andersen, Klaus Kaae; Olsen, Tom Skyhøj

    2018-06-04

    Manifest cancer is associated with increased risk of stroke. The risk of stroke in people with occult cancer in comparison to the risk in the background population without cancer has not been investigated. Smoking is a risk factor for both cancer and stroke, but the role of smoking for the risk of stroke in cancer has not been investigated. We identified all incident cases of cancer in Denmark 2003 to 2012 (n=264.376) from the Danish Cancer Registry. Each person with cancer was matched by age, sex, and income with 10 randomly selected persons without cancer at index date (n=2.571.260). Linking data to the Danish Stroke Registry, we studied risk of ischemic/hemorrhagic stroke the year before (occult cancer) and after cancer diagnosis was established in the Danish Stroke Registry (manifest cancer) and stratified into the 15 most common cancer types related (lung, colon, bladder, rectum, pancreas, kidney, stomach, and head and neck cancer) and unrelated (non-Hodgkin lymphoma, breast, prostate, melanoma, central nervous system, ovary and endometrial) to smoking. Risk of ischemic/hemorrhagic stroke was increased for both occult (relative risk, 1.75/2.00) and manifest cancers (relative risk, 1.30/1.41). For occult cancer, risk of ischemic stroke was increased for all of the smoking-related cancers, but among cancers unrelated to smoking, only lymphoma, central nervous system, and endometrial cancer were associated with increased risk of stroke; breast, prostate, melanoma, and ovarian cancers were not. For occult cancer, risk of hemorrhagic stroke was generally increased for smoking-related cancers while not for cancers unrelated to smoking. For manifest cancer, risk of ischemic and hemorrhagic stroke was generally increased for cancers related to smoking while not for cancers unrelated to smoking. Cancer, occult and manifest, is associated with increased risks for stroke. The increased risk is linked mainly to cancers related to smoking. © 2018 American Heart Association, Inc.

  20. Occult Pelvic Lymph Node Involvement in Bladder Cancer: Implications for Definitive Radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldsmith, Benjamin; Baumann, Brian C.; He, Jiwei

    2014-03-01

    Purpose: To inform radiation treatment planning for clinically staged, node-negative bladder cancer patients by identifying clinical factors associated with the presence and location of occult pathologic pelvic lymph nodes. Methods and Materials: The records of patients with clinically staged T1-T4N0 urothelial carcinoma of the bladder undergoing radical cystectomy and pelvic lymphadenectomy at a single institution were reviewed. Logistic regression was used to evaluate associations between preoperative clinical variables and occult pathologic pelvic or common iliac lymph nodes. Percentages of patient with involved lymph node regions entirely encompassed within whole bladder (perivesicular nodal region), small pelvic (perivesicular, obturator, internal iliac, andmore » external iliac nodal regions), and extended pelvic clinical target volume (CTV) (small pelvic CTV plus common iliac regions) were calculated. Results: Among 315 eligible patients, 81 (26%) were found to have involved pelvic lymph nodes at the time of surgery, with 38 (12%) having involved common iliac lymph nodes. Risk of occult pathologically involved lymph nodes did not vary with clinical T stage. On multivariate analysis, the presence of lymphovascular invasion (LVI) on preoperative biopsy was significantly associated with occult pelvic nodal involvement (odds ratio 3.740, 95% confidence interval 1.865-7.499, P<.001) and marginally associated with occult common iliac nodal involvement (odds ratio 2.307, 95% confidence interval 0.978-5.441, P=.056). The percentages of patients with involved lymph node regions entirely encompassed by whole bladder, small pelvic, and extended pelvic CTVs varied with clinical risk factors, ranging from 85.4%, 95.1%, and 100% in non-muscle-invasive patients to 44.7%, 71.1%, and 94.8% in patients with muscle-invasive disease and biopsy LVI. Conclusions: Occult pelvic lymph node rates are substantial for all clinical subgroups, especially patients with LVI on biopsy. Extended coverage of pelvic lymph nodes up to the level of the common iliac nodes may be warranted in subsets of patients.« less

  1. Genotyping of occult hepatitis B virus infection in Egyptian hemodialysis patients without hepatitis C virus infection.

    PubMed

    Esmail, Mona A; Mahdi, Wafaa K M; Khairy, Rasha M; Abdalla, Nilly H

    2016-01-01

    Occult hepatitis B viral infection is the presence of hepatitis B viral nucleic acids in the serum and/or liver in the absence of hepatitis B surface antigen. The study aimed to determine the prevalence of occult hepatitis B virus infection among hepatitis C virus-negative hemodialysis patients and to identify their genotypes. of 144 patients on maintenance hemodialysis, 50 hepatitis B surface antigen and hepatitis C virus nucleic acid-negative patients were selected according to strict inclusion criteria to avoid the effect of confounding variables. The following investigations were done: serum AST and ALT; HBsAg; HBcAb; HCV-Ab; HCV-RNA; and HBV-DNA. Positive hepatitis B viral nucleic acid was confirmed in 12/144 (8.3%) hemodialysis patients and 12/50 (24%) in our study group (occult infection). Mean hemodialysis periods for negative patients and occult hepatitis B virus patients were 27.3±18.8 and 38.4±8.14 months, respectively, and this difference was significant (p-value=0.02). Mean alanine transaminase levels were 20.27±5.5IU/L and 25.3±9.6 in negative patients and occult infection patients, respectively. This difference was non-significant. Aspartate transaminase levels were 21.4±10.2IU/L and 27.3±4.6IU/L, respectively, in negative patients and infected patients; this difference was significant (p-value=0.03). Half (6/12) of the positive samples belonged to genotype 'B', 33.3% (4/12) to 'C', and 16.6% (2/12) to genotype 'D'. OBI is likely among hemodialysis patients even without HCV coinfection (24%). Genotype D cannot be the only genotype distributed in Upper Egypt, as the current study reported relatively new results that 50% of the patients with occult B carry genotype B, 33.3% carry genotype C and only 16.6% carry genotype D. Copyright © 2015 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  2. Occult Cushing's syndrome in type-2 diabetes.

    PubMed

    Catargi, Bogdan; Rigalleau, Vincent; Poussin, Agathe; Ronci-Chaix, Nathalie; Bex, Veronique; Vergnot, Vincent; Gin, Henri; Roger, Patrick; Tabarin, Antoine

    2003-12-01

    Subclinical Cushing's syndrome (SCS) caused by adrenal incidentalomas is frequently associated with overweight and insulin resistance. Metabolic syndrome X may therefore be a clue to the presence of CS. However, the incidence of CS in this situation remains unknown. We have conducted a prospective study to evaluate the prevalence of occult CS in overweight, type-2 diabetic patients devoided of specific clinical symptoms of CS. Two hundred overweight, type-2 diabetic patients, consecutively referred for poor metabolic control (HbA(1C) > 8%), were studied as inpatients. A first screening step was performed with the 1-mg overnight dexamethasone suppression test (DST) using a revised criterion for cortisol suppression (60 nmol/liter) to maximize the sensitivity of the procedure. A second confirmatory step of biochemical investigations (midnight plasma cortisol concentration, plasma cortisol circadian rhythm, morning plasma ACTH concentration, 24-h urinary free cortisol, and 4-mg i.v. DST) was performed in patients with impaired 1-mg DST. A third step of imaging studies was performed according to the results of second-step investigations. Fifty-two patients had impaired 1-mg DST. Among these, 47 were further evaluated. Thirty were considered as false positives of the 1-mg DST, whereas 17 displayed at least one additional biological abnormality of the hypothalamic-pituitary-adrenal axis. Definitive occult CS was identified in four patients (2% of the whole series) with Cushing's disease (n = 3) and surgically proven adrenal adenoma (n = 1). Definitive diagnosis remains to be established in seven additional patients (3.5%) with mild occult CS associated with unsuppressed plasma ACTH concentrations and a unilateral adrenal tumor of 10-29 mm in size showing prevalent uptake at radiocholesterol scintigraphy. In conclusion, a relatively high prevalence of occult CS was found in our study. Further studies are needed to evaluate the impact of the cure of occult CS on obesity and diabetes mellitus in these patients. Such studies might provide a rationale for systematic screening of occult CS in this population.

  3. Stool guaiac test

    MedlinePlus

    ... guaiac test; gFOBT; Guaiac smear test; Fecal occult blood test - guaiac smear; Stool occult blood test - guaiac smear ... This test detects blood in the digestive tract. It may be done if: You are being screened or tested for colon cancer You ...

  4. Results of two multichord stellar occultations by dwarf planet (1) Ceres

    NASA Astrophysics Data System (ADS)

    Gomes-Júnior, A. R.; Giacchini, B. L.; Braga-Ribas, F.; Assafin, M.; Vieira-Martins, R.; Camargo, J. I. B.; Sicardy, B.; Timerson, B.; George, T.; Broughton, J.; Blank, T.; Benedetti-Rossi, G.; Brooks, J.; Dantowitz, R. F.; Dunham, D. W.; Dunham, J. B.; Ellington, C. K.; Emilio, M.; Herpich, F. R.; Jacques, C.; Maley, P. D.; Mehret, L.; Mello, A. J. T.; Milone, A. C.; Pimentel, E.; Schoenell, W.; Weber, N. S.

    2015-08-01

    We report the results of two multichord stellar occultations by the dwarf planet (1) Ceres that were observed from Brazil on 2010 August 17, and from the USA on 2013 October 25. Four positive detections were obtained for the 2010 occultation, and nine for the 2013 occultation. Elliptical models were adjusted to the observed chords to obtain Ceres' size and shape. Two limb-fitting solutions were studied for each event. The first one is a nominal solution with an indeterminate polar aspect angle. The second one was constrained by the pole coordinates as given by Drummond et al. Assuming a Maclaurin spheroid, we determine an equatorial diameter of 972 ± 6 km and an apparent oblateness of 0.08 ± 0.03 as our best solution. These results are compared to all available size and shape determinations for Ceres made so far, and shall be confirmed by the NASA's Dawn space mission.

  5. Magnetic field orientations in Saturn's upper ionosphere inferred from Voyager radio occultations

    NASA Technical Reports Server (NTRS)

    Hinson, D. P.

    1984-01-01

    The radio scintillations observed during occultations of Voyagers 1 and 2 by Saturn are analyzed to determine the morphology of plasma irregularities and hence the magnetic field orientation in Saturn's upper atmosphere. The measurement techniques, the weak scattering theory, and the method used to relate the observed radio scintillations to physical properties of the ionospheric irregularities are briefly described. Results on the spatial characteristics of the irregularities are presented, and the magnetic field orientation in Saturn's ionosphere is inferred. Although the occultation measurements generally confirm the accuracy of the Saturnian magnetic field model of Connerney et al. (1982), it is found that a small adjustment of the coefficients in that model's zonal harmonic expansion would remove the discrepancy between the model predictions and the measurements. A strategy for obtaining improved measurements of Saturn's magnetic field from radio occultation observations of scintillations and Faraday rotation using an orbiting spacecraft is briefly discussed.

  6. Occult chemical deposition to a Maritime forest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vong, R.J.; Kowalski, A.S.

    1996-12-31

    Studies of chemical fluxes from the atmosphere to vegetated surfaces have suggested that, along with conventional wet and dry processes, an additional chemical input occurs when wind-blown cloud droplets are directly intercepted by vegetation. This cloud water deposition process has been sometimes termed {open_quote}occult deposition{close_quote} because the water fluxes cannot ordinarily be observed using rain gauges. Such occult deposition of cloud water has rarely been measured directly, in part because of the complexity of the governing turbulent transfer process. However, reviews by the National Acidic Precipitation Assessment Program (NAPAP SoS/T-2,6) have suggested that the chemical flux to be forest declinemore » in the eastern USA. This paper presents direct field measurements occult chemical fluxes to a silver fir forest located in complex terrain on the Olympic Peninsula near the coast of Washington State, USA.« less

  7. An integration time adaptive control method for atmospheric composition detection of occultation

    NASA Astrophysics Data System (ADS)

    Ding, Lin; Hou, Shuai; Yu, Fei; Liu, Cheng; Li, Chao; Zhe, Lin

    2018-01-01

    When sun is used as the light source for atmospheric composition detection, it is necessary to image sun for accurate identification and stable tracking. In the course of 180 second of the occultation, the magnitude of sun light intensity through the atmosphere changes greatly. It is nearly 1100 times illumination change between the maximum atmospheric and the minimum atmospheric. And the process of light change is so severe that 2.9 times per second of light change can be reached. Therefore, it is difficult to control the integration time of sun image camera. In this paper, a novel adaptive integration time control method for occultation is presented. In this method, with the distribution of gray value in the image as the reference variable, and the concepts of speed integral PID control, the integration time adaptive control problem of high frequency imaging. The large dynamic range integration time automatic control in the occultation can be achieved.

  8. Calculated occultation profiles of Io and the hot spots

    NASA Technical Reports Server (NTRS)

    Mcewen, A. S.; Soderblom, L. A.; Matson, D. L.; Johnson, T. V.; Lunine, J. I.

    1986-01-01

    Occultations of Io by other Galilean satellites in 1985 provide a means to locate volcanic hot spots and to model their temperatures. The expected time variations in the integral reflected and emitted radiation of the occultations are computed as a function of wavelength (visual to 8.7 microns). The best current ephemerides were used to calculate the geometry of each event as viewed from earth. Visual reflectances were modeled from global mosaics of Io. Thermal emission from the hot spots was calculated from Voyager 1 IRIS observations and, for regions unobserved by IRIS, from a model based on the distribution of low-albedo features. The occultations may help determine (1) the location and temperature distribution of Loki; (2) the source(s) of excess emission in the region from long 50 deg to 200 deg and (3) the distribution of small, high-temperature sources.

  9. First Observations of a Stellar Occultation by KBO (50000) Quaoar from MIT's George R. Wallace, Jr., Astrophysical Observatory

    NASA Astrophysics Data System (ADS)

    Sallum, Stephanie; Brothers, T.; Elliot, J. L.; Person, M. J.; Bosh, A. S.; Zangari, A.; Zuluaga, C.; Levine, S.; Bright, L.; Sheppard, S.; Tilleman, T.

    2011-05-01

    Here we report the first recorded observations of a stellar occultation by Kuiper Belt Object (KBO) (50000) Quaoar. We detected a single-chord stellar occultation by Quaoar of a magnitude 16.2 star designated 26029635 UCAC2 (2MASS ID 1275509401), which occurred on 11 February 2011 UT. The prediction of the occultation was made using long baseline astrometric observations of Quaoar from several sites as part of the MIT Planetary Astronomy Laboratory's continuing effort to improve KBO positions for occultation prediction. The successful observations were made with a Celestron C14 0.36 m telescope and an SBIG STL-1001E CCD camera on a Paramount ME robotic mount. These observations show that a relatively accessible level of astronomical equipment, of the class often used by amateur astronomers, can be used to record KBO occultations. The data were taken at MIT's George R. Wallace, Jr., Astrophysical Observatory in Westford, MA. A light curve was generated from the data using aperture photometry on the individual images and is presented here. This light curve is being analyzed by Person et al. (this meeting) to provide constraints on Quaoar's size. We also discuss various observing strategies that could be used in the future to optimize the data from this type of event. This work was supported in part by grant NNX10AB27G to MIT from NASA's Planetary Astronomy Division. Student participation was supported in part by NSF's REU program, MIT's Undergraduate Research Opportunities Program, NASA's Massachusetts Space Grant, and the George R. Wallace, Jr., Astrophysical Observatory.

  10. Multiple concurrent bilateral groin hernias in a single patient; a case report and a review of uncommon groin hernias: A possible source of persistent pain after successful repair.

    PubMed

    Matsevych, O Y; Koto, M Z; Becker, J H R

    2016-01-01

    The wide use of laparoscopy for groin hernia repair has unveiled "hidden hernias" silently residing in this area. During the open repair of the presenting hernia, the surgeon was often unaware of these occult hernias. These patients postoperatively may present with unexplained chronic groin or pelvic pain. Rare groin hernias are defined according to their anatomical position. Challenges in the diagnosis and management of occult rare groin hernias are discussed. These problems are illustrated by a unique case report of multiple (six) coexisting groin hernias, whereof five were occult and two were rare. Rare groin hernias are uncommon because they are difficult to diagnose clinically and are not routinely looked for. They are often occult and may coexist with other inguinal hernias, thus posing a diagnostic and treatment challenge to the surgeon, especially if there is persistent groin pain after "successful" repair. MRI is the most accurate preoperative and postoperative diagnostic tool, if there is a clinical suspicion that the patient might have an occult hernia. Preperitoneal endoscopic approach is the recommended method in confirming the diagnosis and management of occult groin hernias. A sound knowledge of groin anatomy and a thorough preperitoneal inspection of all possible sites for rare groin hernias are needed to diagnose and repair all defects. The preperitoneal mesh repair with adequate overlap of all hernia orifices is the recommended treatment of choice. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Defining occult injuries of the distal forearm and wrist in children.

    PubMed

    Elvey, Michael; Patel, S; Avisar, Erez; White, W J; Sorene, E

    2016-06-01

    The nonspecific terms "wrist sprain" and "suspected occult bony injury" are frequently documented as diagnoses in occult paediatric wrist injuries. To date, however, no one has accurately defined their true underlying pathology. The primary objective of this study was to identify the true pathoanatomy of occult acute paediatric wrist injuries. Our secondary objective was to compare our findings with existing adult data in order to determine any population differences that might be clinically relevant. We performed a single-centre retrospective case series evaluating MRI findings in acute paediatric wrist injuries presenting to the hand injury unit between 2011 and 2014. All patients underwent standardised radiographs of the wrist and, where clinically indicated, of the scaphoid. Where no bony anomaly was identified, MRI scanning was offered. Cohen's kappa coefficient was used to calculate the agreement between clinical and MRI diagnosis. 57 patients met the final inclusion criteria. Occult fractures and bony contusions comprised the majority of the pathologies, at 36.5 and 35.0 %, respectively. There were no cases of isolated soft-tissue injury. MRI effected management change in 35.1 % of cases. Paediatric wrists demonstrated differences in injury pattern and distribution when compared to an adult population. This study defines for the first time the true pathology of occult paediatric wrist injuries. The current definition of a wrist sprain was not applicable to a single case and therefore appears to be inappropriate for use in the paediatric population. A precise knowledge of the likely pathology facilitates accurate information delivery whilst reducing parental uncertainty and treatment variation.

  12. Feasibility of Juno radio occultations of the Io plasma torus

    NASA Astrophysics Data System (ADS)

    Phipps, P. H.; Withers, P.

    2016-12-01

    Jupiter's magnetosphere is driven by internally produced plasma. The innermost Galilean satellite, Io, isthe dominant source of this plasma. Volcanoes on Io's surface create an atmosphere of sulfur and oxygenwhich escapes into Jupiter's magnetosphere and becomes ionized. This ionized material is trapped byJupiter's magnetic field and creates a torus of plasma centered at Io's orbital radius, called the Io plasmatorus. This torus is divided into three regions distinct in both density and composition. Densities in thistorus can be probed by spacecraft via radio occultations. A radio occultation occurs when plasma comesbetween a spacecraft and a receiver during a time when the spacecraft is sending a radio signal. The Junospacecraft, which arrived in orbit around Jupiter in July 2016, is in an orbit which will be ideal forperforming radio occultations of the Io plasma torus. We test the feasibility of using thetelecommunications system on the Juno spacecraft to perform a radio occultation. Io plasma torusdensities derived from Voyager 1 data are used in creating a model torus. Using the Ka and X-band radiofrequencies we derive vertical profiles for the total electron content of the modeled Io plasma torus. AMarkov Chain Monte Carlo fit is performed on the derived profiles to extract, for each of the torusregions, the scale height and peak total electron content. The scale height can be used to derive atemperature for the torus while the peak total electron content can be used to derive the peak electrondensity. We show that Juno radio occultation measurements of the Io plasma torus are feasible andscientifically valuable.

  13. Local time dependence of the thermal structure in the Venusian equatorial region revealed by Akatsuki radio occultation measurements

    NASA Astrophysics Data System (ADS)

    Ando, H.; Fukuhara, T.; Takagi, M.; Imamura, T.; Sugimoto, N.; Sagawa, H.

    2017-12-01

    The radio occultation technique is one of the most useful methods to retrieve vertical temperature profiles in planetary atmospheres. Ultra-Stable Oscillator (USO) onboard Venus Climate Orbiter, Akatsuki, enables us to investigate the thermal structure of the Venus atmosphere between about 40-90 km levels. It is expected that 35 temperature profiles will be obtained by the radio occultation measurements of Akatsuki until August 2017. Static stability derived from the temperature profiles shows its local time dependence above the cloud top level at low-latitudes equatorward of 25˚. The vertical profiles of the static stability in the dawn and dusk regions have maxima at 77 km and 82 km levels, respectively. A general circulation model (GCM) for the Venus atmosphere (AFES-Venus) reproduced the thermal structures above the cloud top qualitatively consistent with the radio occultation measurements; the maxima of the static stability are seen both in the dawn and dusk regions, and the local maximum of the static stability in the dusk region is located at a highler level than in the dawn region. Comparing the thermal structures between the radio occultation measurements and the GCM results, it is suggested that the distribution of the static stability above the cloud top could be strongly affected by the diurnal tide. The thermal tide influences on the thermal structure as well as atmospheric motions above the cloud level. In addition, it is shown that zonally averaged zonal wind at about 80 km altitude could be roughly estimated from the radio occultation measurements using the dispersion relation of the internal gravity wave.

  14. Laboratory Verification of Occulter Contrast Performance and Formation Flight

    NASA Astrophysics Data System (ADS)

    Sirbu, Dan

    2014-01-01

    Direct imaging of an exo-Earth is a difficult technical challenge. First, the intensity ratio between the parent star and its dim, rocky planetary companion is expected to be ten billion times. Additionally, for a planetary companion in the habitable zone the angular separation to the star is very small, such that only nearby stars are feasible targets. An external occulter is a spacecraft that is flown in formation with the observing space telescope and blocks starlight prior to the entrance pupil. Its shape must be specially designed to control for diffraction and be tolerant of errors such as misalignment, manufacturing, and deformations. In this dissertation, we present laboratory results pertaining to the optical verification of the contrast performance of a scaled occulter and implementation of an algorithm for the alignment of the telescope in the shadow of the occulter. The experimental testbed is scaled from space dimensions to the laboratory by maintaining constant Fresnel numbers while preserving an identical diffraction integral. We present monochromatic results in the image plane showing contrast better than 10 orders of magnitude, consistent with the level required for imaging an Exo-earth, and obtained using an optimized occulter shape. We compare these results to a baseline case using a circular occulter and to the theoretical predictions. Additionally, we address the principal technical challenge in the formation flight problem through demonstration of an alignment algorithm that is based on out-of-band leaked light. Such leaked light can be used a map to estimate the location of the telescope in the shadow and perform fine alignment during science observations.

  15. Novel use of a radiolabelled antibody against stage specific embryonic antigen for the detection of occult abscesses in mammals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thakur, Madhukar L.

    1990-01-01

    The invention discloses improved reagents containing antibodies against stage specific embryonic antigen-1 antibodies and improved methods for detection of occult abscess and inflammation using the improved reagents.

  16. The complete set of Cassini's UVIS occultation observations of Enceladus plume: model fits

    NASA Astrophysics Data System (ADS)

    Portyankina, G.; Esposito, L. W.; Hansen, C. J.

    2017-12-01

    Since the discovery in 2005, plume of Enceladus was observed by most of the instruments onboard Cassini spacecraft. Ultraviolet Imaging Spectrograph (UVIS) have observed Enceladus plume and collimated jets embedded in it in occultational geometry on 6 different occasions. We have constructed a 3D direct simulation Monte Carlo (DSMC) model for Enceladus jets and apply it to the analysis of the full set of UVIS occultation observations conducted during Cassini's mission from 2005 to 2017. The Monte Carlo model tracks test particles from their source at the surface into space. The initial positions of all test particles for a single jet are fixed to one of 100 jets sources identified by Porco et al. (2014). The initial three-dimensional velocity of each particle contains two components: a velocity Vz which is perpendicular to the surface, and a thermal velocity which is isotropic in the upward hemisphere. The direction and speed of the thermal velocity of each particle is chosen randomly but the ensemble moves isotropically at a speed which satisfies a Boltzmann distribution for a given temperature Tth. A range for reasonable Vz is then determined by requiring that modeled jet widths match the observed ones. Each model run results in a set of coordinates and velocities of a given set of test particles. These are converted to the test particle number densities and then integrated along LoS for each time step of the occultation observation. The geometry of the observation is calculated using SPICE. The overarching result of the simulation run is a test particle number density along LoS for each time point during the occultation observation for each of the jets separately. To fit the model to the data, we integrate all jets that are crossed by the LoS at each point during an observation. The relative strength of the jets must be determined to fit the observed UVIS curves. The results of the fits are sets of active jets for each occultation. Each UVIS occultation observation was done under a unique observational geometry. Consequently, the model fits produce different sets of active jets and different minimum Vz. We discuss and compare the results of fitting all UVIS occultation observations.

  17. Occult thyroid carcinoma in our experience -- should we reconsider total thyroidectomy for benign thyroid pathology?

    PubMed

    Alecu, L; Bărbulescu, M; Ursuţ, B; Enciu, O; Slavu, I; Braga, V

    2014-01-01

    The reported incidence rate of occult thyroid carcinoma in patients operated for benign thyroid pathology has been much higher than expected in the last years,especially for multinodular goitre, which raises the question about which should the proper surgical management for these cases be. To assess the incidence rate of OTC in a single medium volume surgical center and to establish the correct indication for initial surgical management, as well as to identify the benign thyroid pathology most frequently associated with OTC. We also reviewed the relevant scientific literature on this topic. We conducted a retrospective study in the General Surgery Clinic of "Prof. dr. Agrippa Ionescu" Clinical Emergency Hospital, Bucharest, on a series of 145 patients who underwent surgical interventions for preoperatively diagnosed benign thyroid pathology over a ten year period, between 1st January 2002 - 31st December 2012. All cases of known thyroid cancer were excluded. Incidence rate of occult thyroid carcinoma in our series was 6.9 % (10 out of 145 patients), 80 % of them being diagnosed with multinodular goitre and two cases (20 %) with Hashimoto's lymphocytic thyroiditis. 6.8 % of all patients with multinodular goitre were found to present occult carcinoma,but this association was without statistical significance(p 0.05). Incidence rate of occult cancer among patients with Hashimoto thyroiditis was proved to be as high as 28.6%,statistically significant (p=0.020). The mean size of postoperatively diagnosed occult microcarcinoma was 7 mm, ranging between 3 mm and 14 mm, 90% of them being smaller than 1cm. Histologically, papillary microcarcinoma was found in all cases. The mean age of the patients diagnosed with occult microcarcinoma was 47.8 years with majority of the female gender. The most frequent operation performed was total thyroidectomy (70.8%). Overall morbidity in our series was 6.9% with a 0.7 % mortality rate (1 case). In our opinion, primary total thyroidectomy should be performed as the procedure of choice for the most part of preoperatively diagnosed benign thyroid pathology and particularly for multinodular goitre and Hashimoto thyroiditis,in order to radically resect all possible foci of aggressive thyroid microcarcinomas.Abbreviations and Acronyms: OTC (Occult Thyroid Carcinoma), PTMC (Papillary Thyroid Microcarcinoma); TT(Total Thyroidectomy), MNG (Multinodular Goitre), GD(Graves' disease), TNG (Toxic Nodular Goitre), FNAB(fine-needle aspiration biopsy). Celsius.

  18. The application of spaceborne GPS to atmospheric limb sounding and global change monitoring

    NASA Technical Reports Server (NTRS)

    Melbourne, W. G.; Davis, E. S.; Duncan, C. B.; Hajj, G. A.; Hardy, K. R.; Kursinski, E. R.; Meehan, T. K.; Young, L. E.; Yunck, T. P.

    1994-01-01

    This monograph is intended for readers with minimal background in radio science who seek a relatively comprehensive treatment of the mission and technical aspects of an Earth-orbiting radio occultation satellite. Part 1 (chapters 1-6) describes mission concepts and programmatic information; Part 2 (chapters 7-12) deals with the theoretical aspects of analyzing and interpreting radio occultation measurements. In this mission concept the navigation signals from a Global Positioning System (GPS) satellite that is being occulted by the Earth's limb are observed by a GPS flight receiver on board a low Earth orbiter (LEO) satellite. This technique can be used to recover profiles of the Earth's atmospheric refractivity, pressure, and temperature using small, dedicated, and relatively low-cost space systems. Chapter 2 summarizes the basic space system concepts of the limb-sounding technique and describes a low-cost strawman demonstration mission. Chapter 3 discusses some of the scientific benefits of using radio occultation on a suite of small satellites. Chapter 4 provides a more detailed discussion of several system elements in a radio occultation mission, including the launch system for small payloads, the LEO microsat, the GPS constellation, the GPS flight receiver payload, the mission operations ground control and data receiving system, the ground-based GPS global tracking network for precision orbit determination, and the central data processing and archive system. Chapter 5 addresses the various technology readiness questions that invariably arise. Chapter 6 discusses the overall costs of a demonstration mission such as GPS/MET (meteorological) proposed by the University Navstar Consortium (UNAVCO). Chapter 7 describes a geometrical optics approach to coplanar atmospheric occultation. Chapter 8 addresses major questions regarding accuracy of the occultation techniques. Chapter 9 describes some simulations that have been performed to evaluate the sensitivity of the recovered profiles of atmospheric parameters to different error sources, such as departure from spherical symmetry, water vapor, etc. Chapter 10 discusses horizontal and vertical resolution associated with limb sounders in general. Chapter 11 treats selected Fresnel diffraction techniques that can be used in radio occultation measurements to sharpen resolution. Chapter 12 provides brief discussions on selected special topics, such as strategies for handling interference and multipath processes that may arise for rays traveling in the lower troposphere.

  19. Metastatic Squamous Neck Cancer with Occult Primary Treatment (PDQ®)—Health Professional Version

    Cancer.gov

    Metastatic squamous neck cancer with occult primary treatment options include surgery, radiation therapy or a combination of both. Get detailed information about newly diagnosed or recurrent metastatic squamous neck cancer in this summary for clinicians.

  20. Novel use of a radiolabelled antibody against stage specific embryonic antigen for the detection of occult abscesses in mammals

    DOEpatents

    Thakur, M.L.

    1990-04-17

    The invention discloses improved reagents containing antibodies against stage specific embryonic antigen-1 antibodies and improved methods for detection of occult abscess and inflammation using the improved reagents. No Drawings

  1. Occultation and Triangulation Camera (OcTriCam) Cubesat

    NASA Astrophysics Data System (ADS)

    Batchelor, D. A.

    2018-02-01

    A camera at Earth-Moon L2 would provide a 240,000 km triangulation baseline to augment near-Earth object observations with Earth-based telescopes such as Pan-STARRS, and planetary occultation research to refine ephemerides and probe ring systems.

  2. All about Occultation.

    ERIC Educational Resources Information Center

    Riddle, Bob

    2001-01-01

    Describes occultation events involving the moon, when the moon blocks the view of planets or stars. Describes other events such as a partial solar eclipse, a penumbral lunar eclipse, meteor showers, and moon phases. Provides a list of internet resources related to these events. (DLH)

  3. TYC 5780-308-1 Discovery of Stellar Duplicity During Asteroidal Occultation by (834) Burnhamia

    NASA Astrophysics Data System (ADS)

    Timerson, Brad; George, T.; Blank, Ted; Maley, Paul; Messner, Steve; Moore, John

    2018-04-01

    An occultation of TYC 5780-308-1 by the asteroid (834) Burnhamia on August 23, 2017 (UT) showed this star to be a double star. Both components of the double star were occulted as recorded by four observers. The separation of the two components is 0.0143 ± 0.0004 arcseconds at a position angle of 73.8 ± 2.7 degrees. The magnitude of the primary component is estimated to be 9.8 +/- 0.03 (Tycho2 VT). The magnitude of the secondary component is estimated to be 9.92 +/- 0.03 (Tycho2 VT).

  4. IRTF observations of the occultation of 28 Sgr by Saturn

    NASA Technical Reports Server (NTRS)

    Harrington, Joseph; Cooke, Maren L.; Forrest, William J.; Pipher, Judith L.; Dunham, Edward W.; Elliot, J. L.

    1993-01-01

    NASA's Mauna Kea IR Telescope Facility obtained an IR-imaging time series for the July 3, 1989 occultation of 28 Sgr by Saturn and its rings; the stellar signal is present in these images throughout the ring occultation event. These data are noted to vary systematically with respect to the Voyager data over large radius scales, perhaps due to stellar signal diffraction through the rings. The stellar diameter, which is projected to be about 20 km, placed most bending- and density-wave trains below measurable resolution. Masses and mean optical depths are presented for individual ring sections.

  5. Does Pluto Have a Haze Layer?

    NASA Technical Reports Server (NTRS)

    Elliot, James L.

    1997-01-01

    The goal of this research was to determine whether Pluto has a haze layer through observations (with the Kuiper Airborne Observatory) of a stellar occultation by Pluto that was originally predicted to occur on 1993 October 3. As described in the attached material, our extensive astrometric measurements determined that this occultation would not be visible from Earth, and we canceled plans to observe it with the KAO. Efforts were then directed toward improving our astrometric techniques so that we could find future occultations with which we could satisfy the original goals of the research proposed for this grant.

  6. Altimetry Using GPS-Reflection/Occultation Interferometry

    NASA Technical Reports Server (NTRS)

    Cardellach, Estel; DeLaTorre, Manuel; Hajj, George A.; Ao, Chi

    2008-01-01

    A Global Positioning System (GPS)- reflection/occultation interferometry was examined as a means of altimetry of water and ice surfaces in polar regions. In GPS-reflection/occultation interferometry, a GPS receiver aboard a satellite in a low orbit around the Earth is used to determine the temporally varying carrier- phase delay between (1) one component of a signal from a GPS transmitter propagating directly through the atmosphere just as the GPS transmitter falls below the horizon and (2) another component of the same signal, propagating along a slightly different path, reflected at glancing incidence upon the water or ice surface.

  7. Study of mutual occultation phenomena of the Galilean satellites at radio wavelengths

    NASA Astrophysics Data System (ADS)

    Pluchino, S.; Salerno, E.; Pupillo, G.; Schillirò, F.; Kraus, A.; Mack, K.-H.

    2010-01-01

    We present preliminary results for our study of mutual phenomena of the Galilean satellites performed at radio wavelengths with the Medicina and Noto antennas of the Istituto di Radioastronomia - INAF, and with the Effelsberg 100-m radio telescope of the Max-Planck-Institute for Radioastronomy, Bonn. Measurements of the radio flux density variation during the mutual occultations of Io by Europa and Ganymede were carried out during the PHEMU09 campaign at 22 GHz and 43 GHz. Flux density variations observed at radio wavelengths are consistent with the typical optical patterns measured when partial occultations occur.

  8. A method to detect occult pneumothorax with chest radiography.

    PubMed

    Matsumoto, Shokei; Kishikawa, Masanobu; Hayakawa, Koichi; Narumi, Atsushi; Matsunami, Katsutoshi; Kitano, Mitsuhide

    2011-04-01

    Small pneumothoraces are often not visible on supine screening chest radiographs because they develop anteriorly to the lung. These pneumothoraces are termed occult. Occult pneumothoraces account for an astonishingly high 52% to 63% of all traumatic pneumothoraces. A 19-year-old obese woman was involved in a head-on car accident. The admission anteroposterior chest radiographs were unremarkable. Because of the presence of right chest tenderness and an abrasion, we suspected the presence of a pneumothorax. Thus, we decided to take a supine oblique chest radiograph of the right side of the thorax, which clearly revealed a visceral pleural line, consistent with a diagnosis of traumatic pneumothorax. A pneumothorax may be present when a supine chest radiograph reveals either an apparent deepening of the costophrenic angle (the "deep sulcus sign") or the presence of 2 diaphragm-lung interfaces (the "double diaphragm sign"). However, in practice, supine chest radiographs have poor sensitivity for occult pneumothoraces. Oblique chest radiograph is a useful and fast screening tool that should be considered for cases of blunt chest trauma, especially when transport of critically ill patients to the computed tomographic suite is dangerous or when imminent transfer to another hospital is being arranged and early diagnosis of an occult pneumothorax is essential. Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  9. Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients.

    PubMed

    Omar, Hesham R; Mangar, Devanand; Khetarpal, Suneel; Shapiro, David H; Kolla, Jaya; Rashad, Rania; Helal, Engy; Camporesi, Enrico M

    2011-09-27

    Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP) chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.

  10. Epidemiology of infertility and polycystic ovarian disease: endocrinological and demographic studies.

    PubMed

    Hull, M G

    1987-09-01

    The frequency of polycystic ovarian disease (PCOD) as a cause of oligo-amenorrhea and infertility was determined, first by characterizing clinically occult PCOD using endocrinological methods, and secondly by estimating the frequency of overt and occult PCOD amongst infertile women residing in a particular area. Four groups of infertile women with oligo-amenorrhea due to 'functional' disorder were compared. The results show that by contrast with the groups having hyperprolactinemia or hypothalamic disorder the group with hirsutism (and therefore presumed PCOD) was closely resembled by a non-hirsute group in terms of estrogenization, LH level, LH/FSH ratio, prolactin level, body mass and responsiveness to clomiphene. The last group was therefore concluded to have a mild occult form of PCOD. The population studies revealed, first, that overt and occult PCOD accounted for 90% of patients with oligomenorrhea and 37% with amenorrhea, or 73% with oligo- or amenorrhea. Oligo- or amenorrhea accounted for 21% of couples with infertility and the annual incidence was 247 patients per million of the general population. The annual incidence of infertility due to PCOD per million was 41 with overt PCOD and 139 with occult PCOD (total 180). Of those, 140 appeared to respond well to clomiphene (78%) but 40 (22%) failed, requiring alternative therapy.

  11. Atmospheric structure and helium abundance on Saturn from Cassini/UVIS and CIRS observations

    NASA Astrophysics Data System (ADS)

    Koskinen, T. T.; Guerlet, S.

    2018-06-01

    We combine measurements from stellar occultations observed by the Cassini Ultraviolet Imaging Spectrograph (UVIS) and limb scans observed by the Composite Infrared Spectrometer (CIRS) to create empirical atmospheric structure models for Saturn corresponding to the locations probed by the occultations. The results cover multiple locations at low to mid-latitudes between the spring of 2005 and the fall of 2015. We connect the temperature-pressure (T-P) profiles retrieved from the CIRS limb scans in the stratosphere to the T-P profiles in the thermosphere retrieved from the UVIS occultations. We calculate the altitudes corresponding to the pressure levels in each case based on our best fit composition model that includes H2, He, CH4 and upper limits on H. We match the altitude structure to the density profile in the thermosphere that is retrieved from the occultations. Our models depend on the abundance of helium and we derive a volume mixing ratio of 11 ± 2% for helium in the lower atmosphere based on a statistical analysis of the values derived for 32 different occultation locations. We also derive the mean temperature and methane profiles in the upper atmosphere and constrain their variability. Our results are consistent with enhanced heating at the polar auroral region and a dynamically active upper atmosphere.

  12. [Not Available].

    PubMed

    Couzinet, M D

    1998-01-01

    The inadequacy of the Galenic theory concerning the effect of medicines prompted Campanella, after Fernel, to define a theory of the occult operation capable of curing those illnesses Hippocrates called "divine", thanks to a "metaphysical science". In his Medicinalia (1609), it is the "primalitary" constitution of living beings - the basic structure of reality whose specific funciton consists in accounting for occult operations in nature in general, and for the occult virtues of some remedies in particular - that is to generate the rules for applying the various medicines to the corresponding parts of the body. Yet its being occult prevents it from providing the medicinal practitioner with the laws of adaptation to its objects. I show that, for Campanella, as well as for Fernel, the solution most probably lies in the use of "method". For, like Fernel, he methodically divides the realm of the occult, the Platonic dichotomy, applied to diseases and remedies, allowing a rational adaptation of the latter to the former, without knowing the nature of either. Thus medical practice possesses its own logic deriving from the nature common to man, the illnesses affecting him, and the medicines that can cure them. Medical efficacy then depends on a capacity for the methodical analysis of natural beings in their complexity, and for taking this into account in therapeutic applications.

  13. Occult spondyloarthritis in inflammatory bowel disease.

    PubMed

    Bandinelli, Francesca; Manetti, Mirko; Ibba-Manneschi, Lidia

    2016-02-01

    Spondyloarthritis (SpA) is a frequent extra-intestinal manifestation in patients with inflammatory bowel disease (IBD), although its real diffusion is commonly considered underestimated. Abnormalities in the microbioma and genetic predisposition have been implicated in the link between bowel and joint inflammation. Otherwise, up to date, pathogenetic mechanisms are still largely unknown and the exact influence of the bowel activity on rheumatic manifestations is not clearly explained. Due to evidence-based results of clinical studies, the interest on clinically asymptomatic SpA in IBD patients increased in the last few years. Actually, occult enthesitis and sacroiliitis are discovered in high percentages of IBD patients by different imaging techniques, mainly enthesis ultrasound (US) and sacroiliac joint X-ray examinations. Several diagnostic approaches and biomarkers have been proposed in an attempt to correctly classify and diagnose clinically occult joint manifestations and to define clusters of risk for patient screening, although definitive results are still lacking. The correct recognition of occult SpA in IBD requires an integrated multidisciplinary approach in order to identify common diagnostic and therapeutic strategies. The use of inexpensive and rapid imaging techniques, such as US and X-ray, should be routinely included in daily clinical practice and trials to correctly evaluate occult SpA, thus preventing future disability and worsening of quality of life in IBD patients.

  14. Pluto-Charon Stellar Occultation Candidates: 1990-1995

    NASA Technical Reports Server (NTRS)

    Dunham, E. W.; McDonald, S. W.; Elliot, J. L.

    1991-01-01

    We have carried out a search to identify stars that might be occulted by Pluto or Charon during the period 1990-1995 and part of 1996. This search was made with an unfiltered CCD camera operated in the strip scanning mode, and it reaches an R magnitude of approximately 17.5-about 1.5 mag fainter than previous searches. Circumstances for each of the 162 potential occultations are given, including an approximate R magnitude of the star, which allows estimation of the signal-to-noise ratio (S/N) for observation of each occultation. The faintest stars in our list would yield an S/N of about 20 for a 1 S integration when observed with a CCD detector on an 8 m telescope under a dark sky. Our astrometric precision (+/- 0.2 arcsec, with larger systematic errors possible for individual cases) is insufficient to serve as a final prediction for these potential occultations, but is sufficient to identify stars deserving of further, more accurate, astrometric observations. Statistically, we expect about 32 of these events to be observable somewhere on Earth. The number of events actually observed will be substantially smaller because of clouds and the sparse distribution of large telescopes. Finder charts for each of the 91 stars involved are presented.

  15. Occurrence of occult CSF leaks during standard FESS procedures.

    PubMed

    Bucher, S; Kugler, A; Probst, E; Epprecht, L; Stadler, R S; Holzmann, D; Soyka, M B

    2018-03-18

    To determine the incidence of occult cerebrospinal fluid leaks (CSF) after functional endoscopic sinus surgery (FESS) and to evaluate the diagnostic performance of beta2-transferrin in blood-contaminated conditions. Prospective cohort study. An analysis of 57 intraoperative samples using hydrogel 6 beta2-transferrin assay after FESS was undertaken. In case of CSF positive samples and continuing rhinorrhea, reanalysis after more than 1 year was conducted. In-vivo analysis of a primary spontaneous CSF leak sample took place to verify difficulties in detecting beta2-transferrin in blood-contaminated settings. Own titrations were performed to evaluate detection limits of CSF by beta2-transferrin and beta-trace protein assays in these settings. An incidence of 13% for occult CSF leaks after FESS was found. In blood-contaminated conditions, routine beta2-transferrin assays showed low sensitivity. In over 1 year follow-up, all samples were negative for CSF and none of them developed clinical relevant CSF leaks or meningitis. Occult and clinically irrelevant CSF leaks do occur in a significant proportion of patients during and shortly after FESS. Intra- and postoperatively, routine beta2-transferrin assays show low sensitivity. They should not be used in these settings. The clinical course of patients with occult CSF leaks indicated possibility of an uneventful follow-up.

  16. Pluto-Charon stellar occultation candidates - 1990-1995

    NASA Technical Reports Server (NTRS)

    Dunham, E. W.; Mcdonald, S. W.; Elliot, J. L.

    1991-01-01

    A search to identify stars that might be occulted by Pluto or Charon during the period 1990-1995 and part of 1996 is studied. This search was made with an unfiltered CCD camera operated in the strip scanning mode, and it reaches an R magnitude of approximately 17.5 - about 1.5 mag fainter than previous searches. Circumstances for each of the 162 potential occultations are given, including an approximate R magnitude of the star, which allows estimation of the signal-to-noise ratio (S/N) for observation of each occultation. The faintest stars in the list would yield an S/N of about 20 for a 1 s integration when observed with a CCD detector on an 8 m telescope under a dark sky. The astrometric precision (+/- 0.2 arcsec, with larger systematic errors possible for individual cases) is insufficient to serve as a final prediction for these potential occultations, but is sufficient to identify stars deserving of further, more accurate, astrometric observations. Statistically, about 32 of these events to be observable somewhere on earth are expected. The number of events actually observed will be substantially smaller because of clouds and the sparse distribution of large telescopes. Finder charts for each of the 91 stars involved are presented.

  17. Retrievals of abundances of hydrocarbon and nitrile species in Titan’s upper atmosphere

    NASA Astrophysics Data System (ADS)

    Yung, Yuk; Fan, Siteng; Shemansky, D. E.; Li, Cheng; Gao, Peter

    2017-10-01

    We develop an innovative retrieval method for Titan occultation measurements by the Cassini UVIS experiment. The T35 occultation is analyzed to illustrate the methodology. A significant number of occultations observed using the UVIS spectrographs show loss of pointing control required for correction of the spectral vectors. Consequently, only three stellar occultations have been analyzed to date. We use the Markov Chain Monte-Carlo (MCMC) method to retrieve the abundances or upper limits of thirteen hydrocarbon and nitrile species (N2, CH4, C2H2, C2H4, C2H6, HCN, C4H2, C6N2, C6H6, tholin, HC3N, C2N2, NH3) along with the pointing error using the Cassini/UVIS simulator. These numbers are derived for the fast T35 occultation, which has never been analyzed because of large pointing errors. Uncertainty in the retrievals is determined using an intrinsic fitting probability distribution function. The Caltech/JPL photochemical and kinetics model, KINETICS, is used to calculate the atmospheric aforementioned species. Comparisons between model and observations reveal gaps in our current understanding of the chemical kinetics of hydrocarbons and nitrile species, especially for C6H6.

  18. The sensitivity, specificity, predictive values, and likelihood ratios of fecal occult blood test for the detection of colorectal cancer in hospital settings.

    PubMed

    Elsafi, Salah H; Alqahtani, Norah I; Zakary, Nawaf Y; Al Zahrani, Eidan M

    2015-01-01

    To study the performance of a single test using two fecal occult blood tests with colonoscopy for the detection of colorectal cancer (CRC) for the first time in Saudi Arabia to determine possible implications for the anticipated colorectal screening program. We compared the performance of guaiac and immunochemical fecal occult blood tests for the detection of CRC among patients of 50-74 years old attending two hospitals in the Eastern Region of Saudi Arabia. Samples of feces were collected from 257 asymptomatic patients and 20 cases of confirmed CRC, and they were tested simultaneously by the guaiac-based occult blood test and monoclonal antibody-based immunoassay kit. Colonoscopy was performed on all participants and the results were statistically analyzed with both positive and negative occult blood tests of both methods. Of the 277 subjects, 79 tested positive for occult blood with at least one method. Overall, the number of those with an occult blood-positive result by both tests was 39 (14.1%), while for 198 (71.5%), both tests were negative (P<0.0001); 40 (14.4%) samples showed a discrepant result. Colonoscopy data were obtained for all 277 patients. A total of three invasive cancers were detected among the screening group. Of the three, the guaiac test detected two cases, while the immunochemical test detected three of them. Of the 20 control cases, the guaiac test detected 13 CRC cases (P=0.03), while the immunochemical test detected 16 of them (P<0.0001). The sensitivity of guaiac and immunochemical tests for the detection of CRC in the screening group was 50.00% (95% confidence interval [CI] =6.76-93.24) and 75.00% (95% CI =19.41-99.37), respectively. For comparison, the sensitivity of the guaiac fecal occult blood test for detecting CRC among the control group was 65.00% (95% CI =40.78-84.61) while that of FIT was 80.00% (95% CI =56.34-94.27). The specificity of the guaiac and immunoassay tests was 77.87% (95% CI =72.24-82.83) and 90.12% (95% CI =85.76-93.50), respectively. The positive likelihood ratio of guaiac and immunochemical tests for the detection of CRC was 2.26 (95% CI =0.83-6.18) and 7.59 (95% CI =3.86-14.94), whereas the negative likelihood ratio was 0.64 (95% CI =0.24-1.71) and 0.28 (95% CI =0.05-1.52), respectively. The positive predictive values of guaiac and immunochemical tests were 3.45% (95% CI =0.426-11.91) and 10.71% (95% CI =2.27-28.23), respectively. There was no marked difference in the negative predictive values for both methods. The sensitivity of the fecal occult blood test by FIT was significantly higher for stages III and IV colorectal cancer than for stages I and II (P=0.01) and it was insignificant for the guaiac fecal occult blood test (P=0.07). In areas where other advance screening methods of CRC are not feasible, the use of FIT can be considered.

  19. Density Waves in Saturn's Rings from Cassini Radio Occultations

    NASA Astrophysics Data System (ADS)

    French, R. G.; Rappaport, N. J.; Marouf, E. A.; McGhee, C. A.

    2005-12-01

    The Cassini Radio Science Team conducted a set of optimized diametric occultations by Saturn and its rings from May to September 2005, providing 11 separate probes of Saturn's ionosphere and atmosphere, and 12 optical depth profiles of the complete ring system. Each event was observed by the stations of the Deep Space Net (DSN) at three radio frequencies (S, X, Ka bands, with corresponding wavelengths of ? = 13, 3.6, and 0.9 cm). Very accurate pointing by the spacecraft and ground antennas resulted in stable baseline signal levels, and the relatively large ring opening angle (B=19-25°) permitted us to probe even quite dense ring regions with excellent SNR. The RSS occultation technique enables us to recover very fine detailed radial structure by correcting for diffraction effects. Multiple occultation chords, covering a variety of ring longitudes and ring opening angles, reveal the structure of the rings in remarkable detail, including density and bending waves, satellite wakes, and subtle variations at the 100-m radius scale. Janus and Epimetheus are responsible for a particularly rich set of density waves, and their coorbital interactions result in a complex interplay of time-variable ring structure over the 8-year libration period of the two satellites. We compare the first-order 2:1, 4:3, 5:4, and 6:5 coorbital density waves from multiple occultation chords to linear density wave models based on a dynamical model of the orbital exchange between the moons. From the observed dispersion relation of the wave crests, we infer the surface mass density and eccentricity gradient of particle streamlines, and match the detailed shapes of the wave crests using a non-linear analysis. Second-order coorbital features are also evident, and there are even hints of third-order density waves in the high SNR radio occultation data.

  20. Comparisons of COSMIC and C/NOFS GPS Occultation Ionospheric Scintillation Measurements with Ground-based Radar and VHF Measurements

    NASA Astrophysics Data System (ADS)

    Ruggiero, F. H.; Groves, K. M.; Straus, P. R.; Caton, R. G.; Starks, M. J.; Tanyi, K. L.; Verlinden, M.

    2009-12-01

    Ionospheric irregularities are known to cause scintillation of trans-ionospheric radio signals and can affect space-based UHF/VHF communications, causing outages, and degrading GPS accuracy and precision. Current capability for characterizing and predicting ionospheric scintillation utilizes a network of ground-based receivers to detect scintillation and then extrapolate for short-term forecasts. Practical limits on deploying the ground receivers limits the accuracy and spatial coverage one can achieve with this approach. A more global approach is to use a set of space-based satellites equipped with GPS receivers, such as the COSMIC satellite constellation, to measure scintillations observed during so-called occultations with GPS satellites. In this paper the signal-to-noise values of GPS L1 signals received on the COSMIC and C/NOFS satellites for the portions of the occultations that are not affected by the terrestrial atmosphere are examined to help identify areas of ionospheric scintillation. Three years of S4 scintillation index values from COSMIC occultations are compared with near-zenith ground-based VHF S4 scintillation measurements from the AFRL SCIntillation Network Decision Aid (SCINDA) network stations. The data are correlated to ascertain the viability of using space-based scintillation measurements to characterize and predict scintillation to ground-based receivers. Several days of COSMIC and C/NOFS data are compared with each other and the ALTAIR radar located on Kwajalein Atoll, Marshall Islands to examine how occultation geometry affects observed scintillation and also to verify techniques that provide an upper bound on the spatial location of the ionospheric irregularities contributing to scintillations observed in the occultations.

  1. Prevalence of occult hepatitis B virus infection in hemodialysis patients in Isfahan, Iran.

    PubMed

    Kalantari, Hamid; Ferdowsi, Faezeh; Yaran, Majid

    2016-01-01

    The absence of a detectable hepatitis B surface antigen (HBsAg) with or without hepatitis B core antibody (anti-HBc) or hepatitis B surface antibody (anti-HBs) in the presence of hepatitis B virus-DNA (HBV-DNA) is defined as occult HBV infection. This study was aimed to evaluate the prevalence of occult HBV infection in patients receiving hemodialysis (HD) in Isfahan, Iran. This cross sectional study was done on 400 patients without acute or chronic HBV infection with end-stage renal disease undergoing regular HD. Blood samples were collected prior to the HD session, and serological markers of viral hepatitis B included HBsAg, anti-HBs and anti-HBc were measured using standard third generation commercially available enzyme immunoassays kit, then samples of positive anti-HBc and negative anti-HBs were tested for HBV DNA using quantitative real-time polymerase chain reaction techniques. Data were analyzed by SPSS using t -test and Chi-square test. The mean age of patients was 51.6 ± 11.2 years. Anti-HBc positive was observed in 32 (8%) of 400 studied patients with negative HBsAg. Of 32 patients with anti-HBc positive, 15 were males and 17 were females with mean age of 49.7 ± 12.6 years. Among 32 patients with anti-HBc positive, 10 patients were negative for anti-HBs. All of 10 patients were negative for HBV DNA. The prevalence of occult HBV infection was 0%. The prevalence of occult HBV infection in HBsAg negative patients undergoing HD was 0% and look to be among the lowest worldwide. So, occult HBV infection is not a significant health problem in HD patients in this region.

  2. The Effect of Early Detection of Occult Brain Metastases in HER2-Positive Breast Cancer Patients on Survival and Cause of Death

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Niwinska, Anna, E-mail: alphaonetau@poczta.onet.p; Tacikowska, Malgorzata; Murawska, Magdalena

    2010-07-15

    Purpose: The aim of the study is to evaluate disease-free survival, survival from the detection of brain metastases, overall survival, and cause of death in patients with occult brain metastases (Group I) vs. patients with symptomatic brain metastases (Group II). Methods and Materials: In 80 HER2-positive breast cancer patients, treated with trastuzumab and cytostatic agents for metastatic disease, magnetic resonance imaging screening of the brain was performed, and in 29 patients (36%) occult brain metastasis was detected (Group I). Whole-brain radiotherapy was delivered to Group I. This first group was compared with 52 patients who had symptomatic brain metastases (Groupmore » II) and was treated the same way, at the same clinic, during the same time period. Results: Median disease-free survival was 17 months in Group I and 19.9 months in Group II (p = 0.58). The median time interval between the dissemination of the disease and the detection of occult or symptomatic brain metastases was 9 and 15 months, respectively (p = 0.11). When the brain metastases were detected, the median survival was 9 and 8.78 months, respectively (p = 0.80). The median overall survival was 53 and 51 months, respectively (p = 0.94). In the group with occult brain metastases (Group I) 16% of patients died because of progression within the brain. In the group with symptomatic brain metastases (Group II) the rate of cerebral death was 48% (p = 0.009). Conclusions: Whole-brain radiotherapy of occult brain metastases in HER2-positive breast cancer patients with visceral dissemination produces a three-fold decrease in cerebral deaths but does not prolong survival.« less

  3. The prevalence of occult endometrial cancer in women undergoing hysterectomy for benign indications.

    PubMed

    Parsons, Lavanya H Palavalli; Pedersen, Rebecca; Richardson, Debra L; Kho, Kimberly A

    2018-04-01

    To estimate the frequency of occult endometrial cancer in women undergoing hysterectomy for benign indications. We performed a retrospective review of all patients undergoing hysterectomies for benign indications at our institution from 2006 to 2014. A departmental database was used to identify all hysterectomies performed, and institutional tumor registry was used to identify cases of endometrial carcinoma. Occult carcinomas were defined as cases with no suspicion preoperatively and histopathologic diagnosis of endometrial cancer postoperatively. A total of 6981 hysterectomies were performed for benign indications. Among these, thirteen patients (0.19%) were found to have occult endometrial cancer, with an overall rate of 1 in 537 patients (95% confidence interval 1:314-1:1008). Twelve patients had stage IA and one had stage IB disease. Median age of women found to have endometrial cancer was 50 years (range 35-72 years). The median BMI was 29.8 kg/m 2 (range 21.3-50.4 kg/m 2 ). The most common indications for hysterectomy were abnormal bleeding (47%), postmenopausal bleeding (15%), adnexal mass (15%), prolapse (15%), and endometrial hyperplasia without atypia (8%). Of the postmenopausal women that had bleeding, all patients underwent evaluation of the endometrium, however 75% of samples did not have adequate amount of endometrium to be evaluated and 25% were found to have hyperplasia. This is one of the largest single institution cohorts to examine occult malignancy. Unexpected endometrial carcinomas were found to occur in 0.19% or 1:537 (95% confidence interval 1:314-1:1008) hysterectomies for benign indications in our population. PRéCIS: Occult endometrial carcinomas are found to occur in 1:537 (0.19%) hysterectomies for benign indications. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Theoretical performance of serrated external occulters for solar coronagraphy. Application to ASPIICS

    NASA Astrophysics Data System (ADS)

    Rougeot, R.; Aime, C.

    2018-04-01

    Context. This study is made in the context of the future solar coronagraph ASPIICS of the ESA formation-flying mission Proba-3. Aims: In the context of solar coronagraphy, we provide a comparative study of the theoretical performance of serrated (or toothed) external occulters by varying the number and size of the teeth, which we compare to the sharp-edged and apodized disks. The tooth height is small (a few centimeters), to avoid hindering the observation of the solar corona near the limb. We first analyze the diffraction pattern produced by such occulters. In a second step, we compute the umbra profile by integration over the Sun. Methods: We explored a few methods to compute the diffraction pattern. Two of them were implemented. The first is based on 2D fast Fourier transformation (FFT) routines and a multiplication by the Fresnel filter of the form exp(-iπλzu2). Simple rules were derived and discussed to set the sampling conditions. The Maggi-Rubinowicz representation is then proposed as an alternative method, and is proven to be very efficient for this study. Results: Serrated occulters tend to create a two-level intensity pattern, the inner being the darker, which perfectly matches a previously reported geometrical prediction. The diffraction in this central region is lower by two to four orders of magnitude when compared to the sharp-edged disk. The achieved umbra level at the center ranges from 10-4 to below 10-7, depending on the geometry of the teeth. Conclusions: Our study shows that serrated occulters can achieve a high rejection and can almost reach the performance of the apodized disk when very many teeth are used. We prove that shaped occulters must be preferred to simple disks in solar and stellar coronagraphy.

  5. [Differences between MDRD-4 and CG in the prevalence of renal failure and its associated variables in type2 diabetic patients].

    PubMed

    Dalmau Llorca, Maria Rosa; Boira Costa, Míriam; López Pablo, Carlos; Pepió Vilaubí, Josep Maria; Aguilar Martin, Carina; Forcadell Drago, Emma

    2016-11-01

    To estimate the prevalence of occult renal failure (RF) in DM2, by comparing two formulas for estimating glomerular filtration rate (GFR): Modification of Diet in Renal Disease 4 (MDRD-4) and Cockcroft-Gault (CG), as well as their associated clinical variables. Multicentre analytical cross-sectional. Two basic Primary Care areas in Terres de l'Ebre, in North-Eastern Spain. A total of 493 DM2 patients with age >18years with an assigned doctor in the areas studied. There was a loss of 9 and 11 cases in each formula due to lack of variables necessary for the GFR. Estimated GFR using the two formulas, plasma creatinine values, classification of patients with established RF, occult RF and without RF, and possible clinical-pathological variables associated with RF. Of the total, 45.2% were men, the mean age was 70.4 years, and mean time since onset of diabetes of 7.5 years. The prevalence of occult RF with MDRD-4 was 18%, and 22.6% with CG. The cases detected by GC and not by MDRD-4 were higher, and with lower weight. In both formulas, occult RF patients had more chronic diseases, hypertension, and cardiovascular events (CV) than those without RF. Risk factors associated with occult RF were female, increasing age, and LDL cholesterol. The prevalence of occult RF was 20% in DM2, independently of the formula. A poorer control of cardiovascular risk factors was observed, which makes them a group at higher risk of suffering a CV event. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  6. Occult HBV among Anti-HBc Alone: Mutation Analysis of an HBV Surface Gene and Pre-S Gene.

    PubMed

    Kim, Myeong Hee; Kang, So Young; Lee, Woo In

    2017-05-01

    The aim of this study is to investigate the molecular characteristics of occult hepatitis B virus (HBV) infection in 'anti-HBc alone' subjects. Twenty-four patients with 'anti-HBc alone' and 20 control patients diagnosed with HBV were analyzed regarding S and pre-S gene mutations. All specimens were analyzed for HBs Ag, anti-HBc, and anti-HBs. For specimens with an anti-HBc alone, quantitative analysis of HBV DNA, as well as sequencing and mutation analysis of S and pre-S genes, were performed. A total 24 were analyzed for the S gene, and 14 were analyzed for the pre-S gene through sequencing. A total of 20 control patients were analyzed for S and pre-S gene simultaneously. Nineteen point mutations of the major hydrophilic region were found in six of 24 patients. Among them, three mutations, S114T, P127S/T, M133T, were detected in common. Only one mutation was found in five subjects of the control group; this mutation was not found in the occult HBV infection group, however. Pre-S mutations were detected in 10 patients, and mutations of site aa58-aa100 were detected in 9 patients. A mutation on D114E was simultaneously detected. Although five mutations from the control group were found at the same location (aa58-aa100), no mutations of occult HBV infection were detected. The prevalence of occult HBV infection is not low among 'anti-HBc alone' subjects. Variable mutations in the S gene and pre-S gene were associated with the occurrence of occult HBV infection. Further larger scale studies are required to determine the significance of newly detected mutations. © Copyright: Yonsei University College of Medicine 2017

  7. Optimal Sunshade Configurations for Space-Based Geoengineering near the Sun-Earth L1 Point.

    PubMed

    Sánchez, Joan-Pau; McInnes, Colin R

    2015-01-01

    Within the context of anthropogenic climate change, but also considering the Earth's natural climate variability, this paper explores the speculative possibility of large-scale active control of the Earth's radiative forcing. In particular, the paper revisits the concept of deploying a large sunshade or occulting disk at a static position near the Sun-Earth L1 Lagrange equilibrium point. Among the solar radiation management methods that have been proposed thus far, space-based concepts are generally seen as the least timely, albeit also as one of the most efficient. Large occulting structures could potentially offset all of the global mean temperature increase due to greenhouse gas emissions. This paper investigates optimal configurations of orbiting occulting disks that not only offset a global temperature increase, but also mitigate regional differences such as latitudinal and seasonal difference of monthly mean temperature. A globally resolved energy balance model is used to provide insights into the coupling between the motion of the occulting disks and the Earth's climate. This allows us to revise previous studies, but also, for the first time, to search for families of orbits that improve the efficiency of occulting disks at offsetting climate change on both global and regional scales. Although natural orbits exist near the L1 equilibrium point, their period does not match that required for geoengineering purposes, thus forced orbits were designed that require small changes to the disk attitude in order to control its motion. Finally, configurations of two occulting disks are presented which provide the same shading area as previously published studies, but achieve reductions of residual latitudinal and seasonal temperature changes.

  8. Optimal Sunshade Configurations for Space-Based Geoengineering near the Sun-Earth L1 Point

    PubMed Central

    Sánchez, Joan-Pau; McInnes, Colin R.

    2015-01-01

    Within the context of anthropogenic climate change, but also considering the Earth’s natural climate variability, this paper explores the speculative possibility of large-scale active control of the Earth’s radiative forcing. In particular, the paper revisits the concept of deploying a large sunshade or occulting disk at a static position near the Sun-Earth L1 Lagrange equilibrium point. Among the solar radiation management methods that have been proposed thus far, space-based concepts are generally seen as the least timely, albeit also as one of the most efficient. Large occulting structures could potentially offset all of the global mean temperature increase due to greenhouse gas emissions. This paper investigates optimal configurations of orbiting occulting disks that not only offset a global temperature increase, but also mitigate regional differences such as latitudinal and seasonal difference of monthly mean temperature. A globally resolved energy balance model is used to provide insights into the coupling between the motion of the occulting disks and the Earth’s climate. This allows us to revise previous studies, but also, for the first time, to search for families of orbits that improve the efficiency of occulting disks at offsetting climate change on both global and regional scales. Although natural orbits exist near the L1 equilibrium point, their period does not match that required for geoengineering purposes, thus forced orbits were designed that require small changes to the disk attitude in order to control its motion. Finally, configurations of two occulting disks are presented which provide the same shading area as previously published studies, but achieve reductions of residual latitudinal and seasonal temperature changes. PMID:26309047

  9. Stellar Occultations by TNOs and Centaurs: first results in the “Gaia era”

    NASA Astrophysics Data System (ADS)

    Rossi, Gustavo; Vieira-Martins, Roberto; Sicardy, Bruno; Ortiz, Jose Luis; Rio Group, Lucky Star Occultation Team, Granada Occultation Team

    2017-10-01

    After the first release of the GAIA catalog (in September/2016), stellar positions are now known with unprecedented accuracy, reaching values of the order of milliarcseconds. This improvement reflected into a stunning accuracy on the astrometry of moving objects, such as TNOs. Unfortunately, Gaia stars proper motions will be only available on the second data release (DR2) next year, so there is still a need to use hybrid stellar catalogs for occultation predictions until then. Despite that, stellar occultations predictions are now much more accurate, and the biggest uncertainties comes mainly from the object ephemerides. This issue will be overcome by large surveys such as the LSST, which will provide positions for the known TNOs and it is expected to increase the number of known TNOs by nearly 40,000, with an unprecedent amount of acquired information.This huge amount of data also poses a new era in stellar occultations: predictions will be very accurate and the participation of professional astronomers, laboratories, and the amateur community will be crucial to observe the predicted events; observation campaigns will need to be selected according to a specific scientific purpose such as the probability to detect rings or archs around a body, the presence of atmosphere or even the detection of topographic features; the development of softwares capable of reducing the data more efficiently and an easier method to coordinate observation campaigns are needed.Here we present some impressive results obtained from predictions and observed occultations in 2017 (among them we have Pluto, Chariklo and Haumea), the problems we are starting to face in the beginning of the “Gaia era” and the future challenges of stellar occultation.

  10. The Research and Education Collaborative Occultation Network: A System for Coordinated TNO Occultation Observations

    NASA Astrophysics Data System (ADS)

    Buie, Marc W.; Keller, John M.

    2016-03-01

    We describe a new system and method for collecting coordinated occultation observations of trans-Neptunian objects (TNOs). Occultations by objects in the outer solar system are more difficult to predict due to their large distance and limited span of the astrometric data used to determine their orbits and positions. This project brings together the research and educational community into a unique citizen-science partnership to overcome the difficulties of observing these distant objects. The goal of the project is to get sizes and shapes for TNOs with diameters larger than 100 km. As a result of the system design it will also serve as a probe for binary systems with spatial separations as small as contact systems. Traditional occultation efforts strive to get a prediction sufficiently good to place mobile ground stations in the shadow track. Our system takes a new approach of setting up a large number of fixed observing stations and letting the shadows come to the network. The nominal spacing of the stations is 50 km so that we ensure two chords at our limiting size. The spread of the network is roughly 2000 km along a roughly north-south line in the western United States. The network contains 56 stations that are committed to the project and we get additional ad hoc support from International Occultation Timing Association members. At our minimum size, two stations will record an event while the other stations will be probing the inner regions for secondary events. Larger objects will get more chords and will allow determination of shape profiles. The stations are almost exclusively sited and associated with schools, usually at the 9-12 grade level. We present a full description of the system we have developed for the continued exploration of the Kuiper Belt.

  11. The global ozone monitoring by occultation of stars (GOMOS) instrument on ENVISAT requirements, design and development status

    NASA Astrophysics Data System (ADS)

    Popescu, Alexandru F.; Paulsen, Togeir; Ratier, Guy

    2018-04-01

    This paper, "The global ozone monitoring by occultation of stars (GOMOS) instrument on ENVISAT requirements, design and development status," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  12. Clinical and mycological study of occult tinea pedis and tinea unguium in dermatological patients from Tokyo.

    PubMed

    Ogasawara, Y; Hiruma, M; Muto, M; Ogawa, H

    2003-04-01

    An epidemiological investigation was conducted to determine the prevalence and circumstances of untreated, unsuspected tinea pedis and tinea unguium, morbid conditions that could be termed occult athlete's foot, in patients visiting a dermatology clinic in Tokyo, Japan, for the first time, for other complaints. All subjects completed a questionnaire covering comprehensive anamnestic details, and were examined for disposition of toes, presence of signs suggestive of tinea pedis, other diseases of the foot, score of clinical signs and symptoms, potassium hydroxide (KOH) test, severity score, and mycological culture. The results showed that the prevalence of occult athlete's foot was 25%, and that 59% of those cases were complicated by tinea unguium. The characteristics of patients with occult athlete's foot included a higher proportion of men and a tendency toward a low clinical score together with a high severity score. In the patient background, a strong correlation was observed between a positive KOH test result and characteristics such as age, disposition of toes, and predisposing disease.

  13. Milliarcsecond resolution infrared observations of young stars in Taurus and Ophiuchus

    NASA Astrophysics Data System (ADS)

    Simon, M.; Howell, R. R.; Longmore, A. J.; Wilking, B. A.; Peterson, D. M.; Chen, W.-P.

    1987-09-01

    The paper reports K-band lunar occultation observations of 18 stars in the Taurus and Ophiuchus star-forming regions. Four of the systems, HQ Tau, FF Tau, and SR 12 and ROX 31 in Ophiuchus, are binaries. Their separations, as observed in the projection along the directions of their occultations, range from about 5 to 186 milliarcseconds (mas). SR 12 was also observed by the technique of speckle interferometry in the J, H, and K bands. These observations, taken together with the lunar occultation results, show that SR 12 is an about 0.30 arcsec binary system whose components are late-type stars still approaching the main sequence. The lunar occultation observations reveal extended structure associated with two objects. Elias 29 in Ophiuchus contains a central component about 7 mas in diameter, that radiates most of the flux, and a much larger diffuse component. YLW 16A, also in Ophiuchus, is an extended object about 0.5 arcsec in diameter.

  14. The Campaign for the Occultation of UCAC4-347-165728 (R=12m2) by Pluto on June 29th, 2015

    NASA Astrophysics Data System (ADS)

    Beisker, W.; Sicardy, B.; Berard, D.; Meza, E.; Herald, D.; Gault, D.; Talbot, J.; Bode, H.-J.; Braga-Ribas, F.; Barry, T.; Broughton, J.; Hanna, W.; Bradshaw, J.; Kerr, S.; Pavlov, H.

    2015-10-01

    The occultation of UCAC4-347-165728 (R=12m2)on the 29th of June 2015 by Pluto is the last important occultation by Pluto before the New Horizons flyby 15 days later. Therefore it is a great opportunity to measure details of Pluto's atmosphere from Earth at the same time as the "on-site" determination. Observations from mobile stations and from certain fixed site observatories are planned in an international campaign in Australia and New Zealand. The telescopes will be equipped with EMCCD or CCD cameras to record a frame sequence linked to the exact timing by GPS. With high resolution astrometry in the months and weeks before the event, we intend to define the central line of the occultation so accurate that a positioning of instruments in close proximity of the central line is possible. - First results of the campaign will be presented in this report.

  15. Decreased sensitivity of early imaging with In-111 oxine-labeled leukocytes in detection of occult infection: concise communication

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Datz, F.L.; Jacobs, J.; Baker, W.

    1984-03-01

    Imaging with leukocytes labeled with indium-111 oxine is a sensitive technique for detecting sites of occult infection. Traditionally, imaging is performed 24 hr after injection. The authors undertook a prospective study of 35 patients (40 studies) with possible occult infection to see whether a 24-hr delay in imaging is really necessary. Patients were imaged at 1-4 hr and again at 24 hr after injection. The early images had a sensitivity of only 33%, compared with 95% for the 24-hr images. Of the seven studies that were positive on both early and delayed images, 71% had more intense uptake at 24more » hr. There were no false-positive early images. It was concluded that imaging 1-4 hr after injection with In-111 oxine-labeled leukocytes has a low sensitivity for detecting occult infection. However, a positive early image is specific for a site of infection.« less

  16. Occult Mediastinal Great Vessel Trauma: The Value of Aortography Performed During Angiographic Screening for Blunt Cervical Vascular Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Charles E.; Bauer, Jason R.; Cothren, C. Clay

    2005-05-15

    Purpose. To determine the value of aortography in the assessment of occult aortic and great vessel injuries when routinely performed during screening angiography for blunt cerebrovascular injury (BCVI). Methods. One hundred and one consecutive patients who received both aortography and screening four-vessel angiography over 4 years were identified retrospectively. Angiograms for these patients were evaluated, and the incidence of occult mediastinal vascular injury was determined. Results. Of the 101 patients, 6 (6%) had angiographically documented traumatic aortic injuries. Of these 6 patients, one injury (17%) was unsuspected prior to angiography. Four of the 6 (67%) also had BCVI. One additionalmore » patient also had an injury to a branch of the subclavian artery. Conclusion. Routine aortography during screening angiography for BCVI is not warranted due to the low incidence (1%) of occult mediastinal arterial injury. However, in the setting of a BCVI screening study and no CT scan of the chest, aortography may be advantageous.« less

  17. Clinical management of occult hemothorax: a prospective study of 81 patients.

    PubMed

    Mahmood, Ismail; Abdelrahman, Husham; Al-Hassani, Ammar; Nabir, Syed; Sebastian, Mark; Maull, Kimball

    2011-06-01

    Intrapleural blood detected by computed tomography scan, but not evident on plain chest radiograph, defines occult hemothorax. This study determined the role for tube thoracostomy. Hemothorax was quantified on computed tomography by measuring the deepest lamellar fluid stripe at the most dependent portion. Data were collected prospectively on demographics, injury mechanism/severity, chest injuries, mechanical ventilation, hospital length of stay, complications, and outcome. Indications for tube thoracostomy were recorded. Tube thoracostomy was avoided in 67 patients (83%). Indications for chest tube placement included progression of hemothorax (8), desaturation (4), and delayed hemothorax (2). Patients with intrapleural fluid thickness greater than 1.5 cm were 4 times more likely to require tube thoracostomy. Occult hemothorax can be managed successfully without tube thoracostomy in most cases. Mechanical ventilation is not an indication for chest tube placement. Accompanying occult pneumothorax may be expected in 50% of cases, but did not affect clinical management. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Occult traumatic hemothorax: when can sleeping dogs lie?

    PubMed

    Bilello, John F; Davis, James W; Lemaster, Deborah M

    2005-12-01

    Size of traumatic occult hemothorax on admission requiring drainage has not been defined. Computed axial tomography (CAT) may guide drainage criteria. A retrospective review of patients with hemothoraces on CAT was performed. Extrapolating previously described methods of pleural fluid measurement, hemothoraces were quantified using the fluid stripe in the dependent pleural "gutter." Data included patient age, injury severity, and intervention (thoracentesis or tube thoracostomy). Seventy-eight patients with 99 occult hemothoraces met the criteria for study inclusion: 52 hemothoraces qualified as "minimal" and 47 as "moderate/large." Eight patients (15%) in the minimal group and 31 patients (66%) in the moderate/large group underwent intervention (P < .001). There was no difference in patient age, injury severity, ventilator requirement, or presence of pulmonary contusion. CAT in stable blunt-trauma patients can predict which patients with occult hemothorax are likely to undergo intervention. Patients with hemothorax > or = 1.5 cm on CAT were 4 times more likely to undergo drainage intervention compared with those having hemothorax < 1.5 cm.

  19. David Levy's Guide to Eclipses, Transits, and Occultations

    NASA Astrophysics Data System (ADS)

    Levy, David H.

    2010-08-01

    Introduction; Part I. The Magic and History of Eclipses: 1. Shakespeare, King Lear, and the Great Eclipse of 1605; 2. Three centuries later: Einstein, relativity, and the solar eclipse of 1919; 3. What causes solar and lunar eclipses; Part II. Observing Solar Eclipses: 4. Safety considerations; 5. What to expect during a partial eclipse; 6. Annular eclipses and what to see in them; 7. Total eclipse of the Sun: introduction to the magic; 8. The onset: temperature drop, Baily's Beads, Diamond Ring; 9. Totality: Corona, Prominences, Chromosphere, and surrounding area; 10. Photographing and imaging a solar eclipse; Part III. Observing Lunar Eclipses: 11. Don't forget the penumbral eclipses!; 12. Partial lunar eclipses; 13. Total lunar eclipses; 14. Photographing and imaging lunar eclipses; Part IV. Occultations: 15. When the Moon occults a star; Part V. Transits: 16. When planets cross the Sun; Part VI. My Favorite Eclipses: 17. A personal canon of eclipses, occultations, and transits I have seen; Appendices; Index.

  20. Revisiting the 1988 Pluto Occultation

    NASA Astrophysics Data System (ADS)

    Bosh, Amanda S.; Dunham, Edward W.; Young, Leslie A.; Slivan, Steve; Barba née Cordella, Linda L.; Millis, Robert L.; Wasserman, Lawrence H.; Nye, Ralph

    2015-11-01

    In 1988, Pluto's atmosphere was surmised to exist because of the surface ices that had been detected through spectroscopy, but it had not yet been directly detected in a definitive manner. The key to making such a detection was the stellar occultation method, used so successfully for the discovery of the Uranian rings in 1977 (Elliot et al. 1989; Millis et al. 1993) and before that for studies of the atmospheres of other planets.On 9 June 1988, Pluto occulted a star, with its shadow falling over the South Pacific Ocean region. One team of observers recorded this event from the Kuiper Airborne Observatory, while other teams captured the event from various locations in Australia and New Zealand. Preceding this event, extensive astrometric observations of Pluto and the star were collected in order to refine the prediction.We will recount the investigations that led up to this important Pluto occultation, discuss the unexpected atmospheric results, and compare the 1988 event to the recent 2015 event whose shadow followed a similar track through New Zealand and Australia.

  1. Celestial Exoplanet Survey Occulter: A Concept for Direct Imaging of Extrasolar Earth-like Planets from the Ground

    NASA Astrophysics Data System (ADS)

    Janson, M.

    2007-02-01

    We present a new concept for detecting and characterizing extrasolar planets down to Earth size or smaller through direct imaging. The New Worlds Observer (NWO) occulter developed by Cash and coworkers is placed in a particular geometrical setup in which fuel requirements are small and the occulter is used in combination with ground-based telescopes, presumably leading to an extreme cost efficiency compared to other concepts with similar science goals. We investigate the various aspects of the given geometry, such as the dynamics and radiation environment of the occulter, and construct a detailed example target list to ensure that an excellent science case can be maintained despite the limited sky coverage. It is found that more than 200 systems can be observed with two to three visits per system, using only a few tons of fuel. For each system, an Earth-sized planet with an Earth-like albedo can be found in the habitable zone in less than 2 hr.

  2. Histogram Analysis of Apparent Diffusion Coefficients for Occult Tonsil Cancer in Patients with Cervical Nodal Metastasis from an Unknown Primary Site at Presentation.

    PubMed

    Choi, Young Jun; Lee, Jeong Hyun; Kim, Hye Ok; Kim, Dae Yoon; Yoon, Ra Gyoung; Cho, So Hyun; Koh, Myeong Ju; Kim, Namkug; Kim, Sang Yoon; Baek, Jung Hwan

    2016-01-01

    To explore the added value of histogram analysis of apparent diffusion coefficient (ADC) values over magnetic resonance (MR) imaging and fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) for the detection of occult palatine tonsil squamous cell carcinoma (SCC) in patients with cervical nodal metastasis from a cancer of an unknown primary site. The institutional review board approved this retrospective study, and the requirement for informed consent was waived. Differences in the bimodal histogram parameters of the ADC values were assessed among occult palatine tonsil SCC (n = 19), overt palatine tonsil SCC (n = 20), and normal palatine tonsils (n = 20). One-way analysis of variance was used to analyze differences among the three groups. Receiver operating characteristic curve analysis was used to determine the best differentiating parameters. The increased sensitivity of histogram analysis over MR imaging and (18)F-FDG PET/CT for the detection of occult palatine tonsil SCC was evaluated as added value. Histogram analysis showed statistically significant differences in the mean, standard deviation, and 50th and 90th percentile ADC values among the three groups (P < .0045). Occult palatine tonsil SCC had a significantly higher standard deviation for the overall curves, mean and standard deviation of the higher curves, and 90th percentile ADC value, compared with normal palatine tonsils (P < .0167). Receiver operating characteristic curve analysis showed that the standard deviation of the overall curve best delineated occult palatine tonsil SCC from normal palatine tonsils, with a sensitivity of 78.9% (15 of 19 patients) and a specificity of 60% (12 of 20 patients). The added value of ADC histogram analysis was 52.6% over MR imaging alone and 15.8% over combined conventional MR imaging and (18)F-FDG PET/CT. Adding ADC histogram analysis to conventional MR imaging can improve the detection sensitivity for occult palatine tonsil SCC in patients with a cervical nodal metastasis originating from a cancer of an unknown primary site. © RSNA, 2015.

  3. Stellar Occultation Probe of Triton's Atmosphere

    NASA Technical Reports Server (NTRS)

    Elliot, James L.

    1998-01-01

    The goals of this research were (i) to better characterize Triton's atmospheric structure by probing a region not well investigated by Voyager and (ii) to begin acquiring baseline data for an investigation of the time evolution of the atmosphere which will set limits on the thermal conductivity of the surface and the total mass of N2 in the atmosphere. Our approach was to use observations (with the Kuiper Airborne Observatory) of a stellar occultation by Triton that was predicted to occur on 1993 July 10. As described in the attached reprint, we achieved these objectives through observation of this occultation and a subsequent one with the KAO in 1995. We found new results about Triton's atmospheric structure from the analysis of the two occultations observed with the KAO and ground-based data. These stellar occultation observations made both in the visible and infrared, have good spatial coverage of Triton including the first Triton central-flash observations, and are the first data to probe the 20-100 km altitude level on Triton. The small-planet light curve model of Elliot and Young (AJ 103, 991-1015) was generalized to include stellar flux refracted by the far limb, and then fitted to the data. Values of the pressure, derived from separate immersion and emersion chords, show no significant trends with latitude indicating that Triton's atmosphere is spherically symmetric at approximately 50 km altitude to within the error of the measurements. However, asymmetry observed in the central flash indicates the atmosphere is not homogeneous at the lowest levels probed (approximately 20 km altitude). From the average of the 1995 occultation data, the equivalent-isothermal temperature of the atmosphere is 47 +/- 1 K and the atmospheric pressure at 1400 km radius (approximately 50 km altitude) is 1.4 +/- 0.1 microbar. Both of these are not consistent with a model based on Voyager UVS and RSS observations in 1989 (Strobel et al, Icarus 120, 266-289). The atmospheric temperature from the occultation is 5 K colder than that predicted by the model and the observed pressure is a factor of 1.8 greater than the model.

  4. Ultrasonography in diagnosing clinically occult groin hernia: systematic review and meta-analysis.

    PubMed

    Kwee, Robert M; Kwee, Thomas C

    2018-05-14

    To provide an updated systematic review on the performance of ultrasonography (US) in diagnosing clinically occult groin hernia. A systematic search was performed in MEDLINE and Embase. Methodological quality of included studies was assessed. Accuracy data of US in detecting clinically occult groin hernia were extracted. Positive predictive value (PPV) was pooled with a random effects model. For studies investigating the performance of US in hernia type classification (inguinal vs femoral), correctly classified proportion was assessed. Sixteen studies were included. In the two studies without verification bias, sensitivities were 29.4% [95% confidence interval (CI), 15.1-47.5%] and 90.9% (95% CI, 70.8-98.9%); specificities were 90.0% (95% CI, 80.5-95.9%) and 90.6% (95% CI, 83.0-95.6%). Verification bias or a variation of it (i.e. study limited to only subjects with definitive proof of disease status) was present in all other studies. Sensitivity, specificity, and negative predictive value (NPV) were not pooled. PPV ranged from 58.8 to 100%. Pooled PPV, based on data from ten studies with low risk of bias and no applicability concerns with respect to patient selection, was 85.6% (95% CI, 76.5-92.7%). Proportion of correctly classified hernias, based on data from four studies, ranged between 94.4% and 99.1%. Sensitivity, specificity and NPV of US in detecting clinically occult groin hernia cannot reliably be determined based on current evidence. Further studies are necessary. Accuracy may strongly depend on the examiner's skills. PPV is high. Inguinal and femoral hernias can reliably be differentiated by US. • Sensitivity, specificity and NPV of ultrasound in detecting clinically occult groin hernia cannot reliably be determined based on current evidence. • Accuracy may strongly depend on the examiner's skills. • PPV of US in detection of clinically occult groin hernia is high [pooled PPV of 85.6% (95% confidence interval, 76.5-92.7%)]. • US has very high performance in correctly differentiating between clinically occult inguinal and femoral hernia (correctness of 94.4- 99.1%).

  5. Recurring Occultations of RW Aurigae by Coagulated Dust in the Tidally Disrupted Circumstellar Disk

    NASA Astrophysics Data System (ADS)

    Rodriguez, Joseph E.; Reed, Phillip A.; Siverd, Robert J.; Pepper, Joshua; Stassun, Keivan G.; Gaudi, B. Scott; Weintraub, David A.; Beatty, Thomas G.; Lund, Michael B.; Stevens, Daniel J.

    2016-02-01

    We present photometric observations of RW Aurigae, a Classical T Tauri system, that reveal two remarkable dimming events. These events are similar to that which we observed in 2010-2011, which was the first such deep dimming observed in RW Aur in a century’s worth of photometric monitoring. We suggested the 2010-2011 dimming was the result of an occultation of the star by its tidally disrupted circumstellar disk. In 2012-2013, the RW Aur system dimmed by ˜0.7 mag for ˜40 days and in 2014/2015 the system dimmed by ˜2 mag for >250 days. The ingress/egress duration measurements of the more recent events agree well with those from the 2010-2011 event, providing strong evidence that the new dimmings are kinematically associated with the same occulting source as the 2010-2011 event. Therefore, we suggest that both the 2012-2013 and 2014-2015 dimming events, measured using data from the Kilodegree Extremely Little Telescope and the Kutztown University Observatory, are also occultations of RW Aur A by the tidally disrupted circumstellar material. Recent hydrodynamical simulations of the eccentric fly-by of RW Aur B suggest the occulting body to be a bridge of material connecting RW Aur A and B. These simulations also suggest the possibility of additional occultations which are supported by the observations presented in this work. The color evolution of the dimmings suggest that the tidally stripped disk material includes dust grains ranging in size from small grains at the leading edge, typical of star-forming regions, to large grains, ices or pebbles producing gray or nearly gray extinction deeper within the occulting material. It is not known whether this material represents arrested planet building prior to the tidal disruption event, or perhaps accelerated planet building as a result of the disruption event, but in any case the evidence suggests the presence of advanced planet building material in the space between the two stars of the RW Aur system.

  6. Probing Pluto's Atmosphere Using Ground-Based Stellar Occultations

    NASA Astrophysics Data System (ADS)

    Sicardy, Bruno; Rio de Janeiro Occultation Team, Granada Team, International Occultation and Timing Association, Royal Astronomical Society New Zealand Occultation Section, Lucky Star associated Teams

    2016-10-01

    Over the last three decades, some twenty stellar occultations by Pluto have been monitored from Earth. They occur when the dwarf planet blocks the light from a star for a few minutes as it moves on the sky. Such events led to the hint of a Pluto's atmosphere in 1985, that was fully confirmed during another occultation in 1988, but it was only in 2002 that a new occultation could be recorded. From then on, the dwarf planet started to move in front of the galactic center, which amplified by a large factor the number of events observable per year.Pluto occultations are essentially refractive events during which the stellar rays are bent by the tenuous atmosphere, causing a gradual dimming of the star. This provides the density, pressure and temperature profiles of the atmosphere from a few kilometers above the surface up to about 250 km altitude, corresponding respectively to pressure levels of about 10 and 0.1 μbar. Moreover, the extremely fine spatial resolution (a few km) obtained through this technique allows the detection of atmospheric gravity waves, and permits in principle the detection of hazes, if present.Several aspects make Pluto stellar occultations quite special: first, they are the only way to probe Pluto's atmosphere in detail, as the dwarf planet is far too small on the sky and the atmosphere is far too tenuous to be directly imaged from Earth. Second, they are an excellent example of participative science, as many amateurs have been able to record those events worldwide with valuable scientific returns, in collaboration with professional astronomers. Third, they reveal Pluto's climatic changes on decade-scales and constrain the various seasonal models currently explored.Finally, those observations are fully complementary to space exploration, in particular with the New Horizons (NH) mission. I will show how ground-based occultations helped to better calibrate some NH profiles, and conversely, how NH results provide some key boundary conditions necessary to analyze ground-based data.Part of the research leading to these results has received funding from the European Research Council under the European Community's H2020 (2014-2020/ ERC Grant Agreement n 669416 "LUCKY STAR").

  7. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    NASA Technical Reports Server (NTRS)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

  8. Pulmonary uptake in Indium-111 leukocyte imaging: clinical significance in patients with suspected occult infections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, P.S.; Datz, F.L.; Disbro, M.A.

    1984-02-01

    A retrospective review was undertaken to evaluate the frequency and significance of pulmonary activity noted on 306 indium-111 leukocyte studies involving 232 patients with suspected occult infections. Forty-eight studies showed pulmonary activity in one of two patterns of uptake, focal or diffuse. Fourteen of 27 studies (52%) with focal uptake and two of 21 studies (10%) with diffuse uptake were associated with infectious processes. Lung uptake of indium-111-labeled leukocytes was a poor predictor of pulmonary infection in patients studied for occult infection, although the focal pattern was more likely than the diffuse pattern to be associated with infection.

  9. Investigation of the small-scale structure and dynamics of Uranus' atmosphere

    NASA Technical Reports Server (NTRS)

    Eshleman, Von R.; Hinson, David P.

    1991-01-01

    This document constitutes the final technical report of the Uranus Analysis Program. Papers and/or abstracts resulting from this research are presented. The following topics are covered: (1) past and future of radio occultation studies of planetary atmospheres; (2) equatorial waves in the stratosphere of Uranus; (3) the atmosphere of Uranus- results of radio occultation measurements with Voyager 2; (4) Uranus' atmospheric dynamics and circulation; (5) small-scale structure and dynamics in the atmosphere of Uranus; (6) evidence for inertia-gravity waves in the stratosphere of Uranus derived from Voyager 2 radio occultation data; and (7) planetary waves in the equatorial stratosphere of Uranus.

  10. The thermal structure and energy balance of the Uranian upper atmosphere

    NASA Technical Reports Server (NTRS)

    French, R. G.; Dunham, E. W.; Allen, D. A.; Elias, J. H.; Frogel, J. A.; Elliot, J. L.; Liller, W.

    1983-01-01

    Uranus upper atmosphere occultation observations are reported for August 15-16, 1980, and April 26, 1981. Mean atmospheric light curves of 154 + or - 15 K and 132 + or - 15 K, respectively, are derived from the light curves. A comparison of all available Uranus occultation data since March 1977 suggests a significant mean atmospheric temperature change, with a typical 15 K/year variation. It is suggested that molecular and eddy diffusion, together with atmospheric dynamics, are potentially as important as radiation in the upper atmosphere heat balance of Uranus. The close agreement of occultation immersion and emersion temperatures further suggests that effective meridional transport occurs on Uranus.

  11. Direct imaging of extra-solar planets with stationary occultations viewed by a space telescope

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.

    1978-01-01

    The use of a telescope in space to detect planets outside the solar system by means of imaging at optical wavelengths is discussed. If the 'black' limb of the moon is utilized as an occulting edge, a hypothetical Jupiter-Sun system could be detected at a distance as great as 10 pc, and a signal-to-noise ratio of 9 could be achieved in less than 20 min with a 2.4 m telescope in space. An orbit for the telescope is proposed; this orbit could achieve a stationary lunar occultation of any star for a period of nearly two hours.

  12. Occultations by 81 Terpsichore and 694 Ekard in 2009 at Different Rotational Phase Angles

    NASA Astrophysics Data System (ADS)

    Timerson, Brad; Durech, J.; Pilcher, F.; Albers, J.; Beard, T.; Berger, B.; Berman, B.; Breit, D.; Case, T.; Collier, D.; Dantowitz, R.; Davies, T.; Desmarais, V.; Dunham, D.; Dunham, J.; Garlitz, J.; Garrett, L.; George, T.; Hill, M.; Hughes, Z.; Jacobson, G.; Kozubal, M.; Liu, Y.; Maley, P.; Morgan, W.; Morris, P.; Mroz, G.; Pool, S.; Preston, S.; Shelton, R.; Welch, S.; Westfall, J.; Whitman, A.; Wiggins, P.

    2010-10-01

    During 2009, IOTA observers in North America reported about 250 positive observations for 94 asteroidal occultation events. For two asteroids this included observations of multiple chords on two different dates which allowed well-defined profiles to be obtained at different rotational phase angles. Occultations by 81 Terpsichore on 2009 November 19 and 2009 December 25 yielded best-fit ellipses of 134.0 x 108.9 km and 123.6 x 112.2 km, respectively. Observations of 694 Ekard on 2009 September 23 and 2009 November 8 yielded fitted ellipses of 124.9 x 88.0 km and 88.5 x 104.0 km, respectively.

  13. Occultation of 2UCAC 42376428 by (423) Diotima on 2005 March 06

    NASA Astrophysics Data System (ADS)

    Vasundhara, R.; Kuppuswamy, K.; Ramamoorthy, S.; Velu, C.; Venkataramana, A. K.

    2006-03-01

    Observations of the occultation of the star 2UCAC 42376428 by (423) Diotima on 2005 March 06 at the Vainu Bappu Observatory are reported. The observed mid time of the event at 15:12:25.1 UT occurred 3.4 s later than the predicted time but within the 1 uncertainty of 4.3 s of the predictions by IOTA. The duration of the event of 4.2 s was found to be shorter than the predictions even allowing for a one sigma uncertainty in the impact parameter. This implies a narrower projected width of the asteroid along the occultation track at the time of the event.

  14. Sizes of the Smallest Particles at Saturn Ring Edges from Diffraction in UVIS Stellar Occultations

    NASA Astrophysics Data System (ADS)

    Eckert, S.; Colwell, J. E.; Becker, T. M.; Esposito, L. W.

    2017-12-01

    Cassini's Ultraviolet Imaging Spectrograph (UVIS) has observed more than 150 ring stellar occultations since its arrival at Saturn in 2004. We use stellar occultation data from the UVIS High Speed Photometer (HSP) to identify diffraction signals at ring edges caused by small particles diffracting light into the detector and consequently increasing the signal above that of the unocculted star. The shape of a diffraction signal is indicative of the particle size distribution at the ring edge, which may be a dynamically perturbed region. Becker et al. (2015 Icarus doi:10.1016/j.icarus.2015.11.001) analyzed diffraction signals at the outer edge of the A Ring and the edges of the Encke Gap. We apply the Becker et al. (2015) model to the outer edge of the B Ring as well as the edges of ringlets within the C Ring and Cassini Division. In addition, we analyze diffraction signatures at the A Ring outer edge in 2 new occultations. The best-fit model signals to these occultations are consistent with the findings of Becker et al. (2015) who found an average minimum particle size amin =4.5 mm and average power law slope q=3.2. At the B Ring outer edge, we detect a diffraction signal in 10 of 28 occultations in which the diffraction signal would be observable according to our criteria for star brightness and observation geometry. We find a mean amin =11 mm and a mean q=3.0. At both edges of the so-called "Strange" ringlet (R6) we find a mean amin = 20 mm and mean q values of 3.0 and 2.8 at the inner and outer edges, respectively. In contrast, we do not observe any clear diffraction signals at either edge of the wider Huygens ringlet. This could imply an absence of cm-scale or smaller particles and indicates that collisions here may be less vigorous than at the other ring edges analyzed in this study. We detect diffraction in a small fraction ( 10%) of occultations at 3 ringlets within the Cassini Division: the Herschel ringlet, the Laplace ringlet, and the Barnard ringlet. We also found diffraction signals in only 2 of 30 occultations of the Maxwell ringlet in the C Ring. These ringlet diffraction signals, when present, indicate larger minimum particle sizes than seen in the outer A Ring and B ring edge.

  15. Space and ground segment performance of the FORMOSAT-3/COSMIC mission: four years in orbit

    NASA Astrophysics Data System (ADS)

    Fong, C.-J.; Whiteley, D.; Yang, E.; Cook, K.; Chu, V.; Schreiner, B.; Ector, D.; Wilczynski, P.; Liu, T.-Y.; Yen, N.

    2011-01-01

    The FORMOSAT-3/COSMIC (Constellation Observing System for Meteorology, Ionosphere, and Climate) mission consisting of six Low-Earth-Orbit (LEO) satellites is the world's first demonstration constellation using radio occultation signals from Global Positioning System (GPS) satellites. The radio occultation signals are retrieved in near real-time for global weather/climate monitoring, numerical weather prediction, and space weather research. The mission has processed on average 1400 to 1800 high-quality atmospheric sounding profiles per day. The atmospheric radio occultation soundings data are assimilated into operational numerical weather prediction models for global weather prediction, including typhoon/hurricane/cyclone forecasts. The radio occultation data has shown a positive impact on weather predictions at many national weather forecast centers. A proposed follow-on mission transitions the program from the current experimental research system to a significantly improved real-time operational system, which will reliably provide 8000 radio occultation soundings per day. The follow-on mission as planned will consist of 12 satellites with a data latency of 45 min, which will provide greatly enhanced opportunities for operational forecasts and scientific research. This paper will address the FORMOSAT-3/COSMIC system and mission overview, the spacecraft and ground system performance after four years in orbit, the lessons learned from the encountered technical challenges and observations, and the expected design improvements for the new spacecraft and ground system.

  16. External occulter laboratory demonstrator for the forthcoming formation flying coronagraphs.

    PubMed

    Landini, Federico; Vives, Sébastien; Venet, Mélanie; Romoli, Marco; Guillon, Christophe; Fineschi, Silvano

    2011-12-20

    The design and optimization of the external occulter geometry is one of the most discussed topics among solar coronagraph designers. To improve the performance of future coronagraphs and to stretch their inner fields of view toward the solar limb, the new concept of coronagraphs in formation flight has been introduced in the scientific debate. Solar coronagraphs in formation flight require several mechanical and technological constraints to be met, mainly due to the large dimension of the occulter and to the spacecraft's reciprocal alignment. The occulter edge requires special attention to minimize diffraction while being compatible with the handling and integrating of large delicate space components. Moreover, it is practically impossible to set up a full-scale model for laboratory tests. This article describes the design and laboratory tests on a demonstrator for a coronagraph to be operated in formation flight. The demonstrator is based on the principle of the linear edge, thus the presented results cannot be directly extrapolated to the case of the flying circular occulter. Nevertheless, we are able to confirm the results of other authors investigating on smaller coronagraphs and provide further information on the geometry and tolerances of the optimization system. The described work is one of the results of the ESA STARTIGER program on formation flying coronagraphs ["The STARTIGER's demonstrators: toward a new generation of formation flying solar coronagraphs," in 2010 International Conference on Space Optics (ICSO) (2010), paper 39].

  17. Software and hardware complex for observation of star occultations by asteroids

    NASA Astrophysics Data System (ADS)

    Karbovsky, V.; Kleshchonok, V.; Buromsky, M.

    2017-12-01

    The preparation to the program for observation of star occultations by asteroids on the AZT-2 telescope was started in 2016. A new method for registration of occultation with a CCD camera in the synchronous transfer mode was proposed and developed. The special program was written to control the CCD camera and record images during such observations. The speed of image transfer can vary within wide limits, which makes it possible to carry out observations in a wide range of stellar magnitudes. The telescope AZT-2 is used, which has the largest mirror diameter in Kiev (D = 0.7 m. F = 10.5 m). A 3-fold optical reducer was produced, which providing a field of view with a CCD camera Apogee Alta U47 10 arcminutes and the equivalent focal length of the telescope 3.2 meters. The results of test observations are presented. The program is implemented jointly by the Main Astronomical Observatory of the National Academy of Sciences of Ukraine and the Astronomical Observatory of the Taras Shevchenko National University of Kyiv. Regular observations of star occultation by asteroids are planned with the help of this complex. % Z https://occultations.org Kleshchonok,V.V.,Buromsky,M. I. 2005, Kinematics and Physics of Celestial Bodies, 21, 5, 405 Kleshchonok, V.V., Buromskii, N. I., Khat’ko,I.V.2008, Kinematics and Physics of Celestial Bodies, 24, 2, 114

  18. Prospective Evaluation of Intrahepatic Microscopic Occult Tumor Foci in Patients with Numerous Colorectal Liver Metastases.

    PubMed

    Vigano, Luca; Di Tommaso, Luca; Mimmo, Antonio; Sollai, Mauro; Cimino, Matteo; Donadon, Matteo; Roncalli, Massimo; Torzilli, Guido

    2018-06-07

    Patients with numerous colorectal liver metastases (CLM) have high risk of early recurrence after liver resection (LR). The presence of intrahepatic occult microscopic metastases missed by imaging has been hypothesized, but it has never been assessed by pathology analyses. All patients with > 10 CLM who underwent LR between September 2015 and September 2016 were considered. A large sample of liver without evidence of disease ("healthy liver") was taken from the resected specimen and sent to the pathologist. One mm-thick sections were analyzed. Any metastasis, undetected by preoperative and intraoperative imaging, but identified by the pathologist was classified as occult microscopic metastasis. Ten patients were prospectively enrolled (median number of CLM n = 15). In a per-lesion analysis, the sensitivity of computed tomography and magnetic resonance imaging was 91 and 98% respectively. The pathology examination confirmed all the CLM. All patients had an adequate sample of "healthy liver" (median number of examined blocks per sample n = 14 [5-33]). No occult microscopic metastases were detected. After a median follow-up of 15 months, 5 patients were disease-free. Recurrence was hepatic and bilobar in all patients. Clinically relevant occult microscopic disease in patients with numerous CLM is excluded. These results support the indication to resection in such patients and exclude the need for de principe major hepatectomy to increase the completeness of surgery. © 2018 S. Karger AG, Basel.

  19. Occult Hepatitis B Virus Among the Patients With Abnormal Alanine Transaminase

    PubMed Central

    Makvandi, Manoochehr; Neisi, Niloofar; Khalafkhany, Davod; Makvandi, Kamyar; Hajiani, Eskandar; Shayesteh, Ali Akbar; Masjedi Zadeh, Abdolrahim; Sina, Amir Hosein; Hamidifard, Mojtaba; Rasti, Mojtaba; Aryan, Ehsan; Ahmadi, Kambiz; Yad Yad, Mohammad Jafar

    2014-01-01

    Background: The occult hepatitis B infection (OBI) is defined as the presence of hepatitis B virus (HBV) DNA in the sera or in the liver biopsy and the absence of hepatitis B surface antigen (HBsAg) by serological test. Objectives: The current study aimed to evaluate the occult HBV infection by polymerase chain reaction (PCR) and determine HBV genotyping among the patients with abnormal alanine transaminase (ALT) in Ahvaz city, Iran. Patients and Methods: The sera of 120 patients, 54 (45%) females and 66 (55%) males, with abnormal ALT 40-152 IU were collected. All the patients were negative for HBsAg for more than one year. The patients` sera were tested by PCR using primers specified for the S region of HBV. Then the positive PCR products were sequenced to determine HBV genotyping and phylogenic tree. Results: Of these 120 subjects, 12 (10%) patients including 6 (5%) males and 6 (5%) females were found positive for HBV DNA by PCR, which indicated the presence of occult HBV infection among these patients. The sequencing results revealed that genotype D was predominant with sub-genotyping D1 among OBI patients. Conclusions: Occult hepatitis B infection is remarkably prevalent in Ahvaz, Iran, and should be considered as a potential risk factor for the transmission of Hepatitis B Virus throughout the community by the carriers. PMID:25485052

  20. The State of Pluto's Bulk Atmosphere at the Time of the New Horizons Encounter

    NASA Astrophysics Data System (ADS)

    Resnick, Aaron C.; Barry, T.; Buie, M. W.; Carriazo, C. Y.; Cole, A.; Gault, D.; Giles, B.; Giles, D.; Hartig, K.; Hill, K.; Howell, R. R.; Hudson, G.; Loader, B.; Mackie, J.; Nelson, M.; Olkin, C.; Register, J.; Rodgers, T.; Sicardy, B.; Skrutskie, M.; Verbiscer, A.; Wasserman, L.; Watson, C.; Young, E.; Young, L.; Zalucha, A.

    2015-11-01

    On 29-JUL-2015, our team - plus many critical amateur astronomers - observed a stellar occultation by Pluto from sites in Australia and New Zealand. This event was remarkable for two reasons: it preceded the New Horizons flyby of Pluto by just two weeks, and the occulted star was about 10x brighter than Pluto itself, by far the brightest Pluto occultation event observed to date. The separation of ground sites spanned nearly 900 km with respect to the central chord, allowing a good geometric solution for the shadow path. The lightcurves show some inflection points and broad "fangs" that are characteristic of perturbations in the temperature profile. Preliminary fits show that the temperature profile derived from a 2006 occultation (Young et al. 2008) reproduces the 29-JUN-2015 lightcurves well. Assuming a surface radius of 1187 km for Pluto, we find that the surface pressure is 18 +/- 3 µbar. This pressure indicates that Pluto's surface has not yet started to cool down, despite a decrease in absorbed solar flux of more than 17% since perihelion in 1988. A surface pressure of 18 µbar would correspond to a nitrogen ice surface temperature of 38.0 K.References:Young, E.F., et al. "Vertical Structure in Pluto's Atmosphere from the 2006 June 12 Stellar Occultation," AJ 136 1757-1769 (2008)

  1. Occult bacteraemia is uncommon in febrile infants who appear well, and close clinical follow-up is more appropriate than blood tests.

    PubMed

    Hernandez-Bou, Susanna; Trenchs, Victoria; Batlle, Astrid; Gene, Amadeu; Luaces, Carles

    2015-02-01

    The rate of paediatric occult bacteraemia after the introduction of the 13-valent pneumococcal conjugated vaccine is relatively unknown. We determined the rate, and identified isolated pathogens, in children aged three to 36 months who presented to a paediatric emergency department with fever, but otherwise appeared well. We also analysed the yield of laboratory parameters traditionally considered risk factors for occult bacteraemia. Children aged three to 36 months who were febrile, but otherwise appeared well, were included if they had blood tests in the paediatric emergency department between April 2010 and September 2012. Of the 591 patients, only six (1.0%) had a true bacterial pathogen and three of those were Streptococcus pneumoniae (0.5%). None of the children with pneumococcal bacteraemia had been immunised. The contaminant rate was 2.7%, and an elevated band count was the best predictor of occult bacteraemia, with positive and negative likelihood ratios of 10 and 0.4, respectively. The yield of the other laboratory parameters was very limited. In the era of the 13-valent pneumococcal conjugated vaccine, occult bacteraemia is an uncommon event in febrile children aged three to 36 who otherwise appear well and close follow-up should replace blood analysis in such cases. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. A Search for Satellites of Kuiper Belt Object 55636 from the 2009 October 9 Occultation

    NASA Astrophysics Data System (ADS)

    Jensen-Clem, Rebecca; Elliot, J. L.; Person, M. J.; Zuluaga, C. A.; Bosh, A. S.; Adams, E. R.; Brothers, T. C.; Gulbis, A. A. S.; Levine, S. E.; Lockhart, M.; Zangari, A. M.; Babcock, B. A.; DuPre, K.; Pasachoff, J. M.; Souza, S. P.; Rosing, W.; Secrest, N.; Bright, L.; Dunham, E. W.; Kakkala, M.; Tilleman, T.; Rapoport, S.; Zambrano-Marin, L.; Wolf, J.; Morzinski, K.

    2011-01-01

    A world-wide observing campaign of 21 telescopes at 18 sites was organized by Elliot et al. (2010 Nature 465, 897) to observe the 2009 Oct. 9 stellar occultation of 2UCAC 41650964 (UCAC2 magnitude 13.1) by the Kuiper Belt object 55636 (visual magnitude 19.6). Integration times varied between 0.05 seconds at the Vatican Advanced Technology Telescope and 5 seconds at Mauna Kea mid-level. Data from the two sites that successfully observed the occultation (Haleakala and the Mauna Kea mid-level) were analyzed by Elliot et al. (2010) to determine the diameter and albedo of 55636. In this study, we use the entire data set to search for signatures of occultations by nearby satellites. One satellite previously discovered with occultation data is Neptune's moon Larissa, which was detected during Neptune's close approach to a star in 1982 (Reitsema et al. 1982). No satellites are found in this study, and upper limits will be reported on satellite radii within the volume probed (2 x 10-8 of the Hill Sphere). This work was supported, in part, by NASA Grants NNX10AB27G (MIT), NNX08AO50G (Williams College), and NNH08AI17I (USNO-FS) and NSF Grant AST-0406493 (MIT). Student participation was supported in part by NSF's REU program and NASA's Massachusetts Space Grant.

  3. Overview of SPICAV occultation results for the UV channel

    NASA Astrophysics Data System (ADS)

    Montmessin, Franck; Bertaux, Jean-Loup; Belyaev, Denis; Marcq, Emmanuel; Korablev, Oleg; Vandaele, Ann-Carine; Fedorova, Anna

    The SPICAV instrument onboard the Venus Express spacecraft is a multi-channel suite cov-ering the far ultraviolet to the mid-infrared. In this presentation, we will focus on the results obtained by the UV channel during stellar occultations observations. Stellar occultation tech-nique possesses well-known advantages: self-calibration, low sensitivity to instrument aging, simple laws of radiative transfer. In addition, occultation with stars permit to cover a broad range of latitudes at any given season and they provide optimal geometrical registration. Since Venus Express orbit insertion, several hundreds of occultations have been performed by SPI-CAV, yielding profiles of atmospheric constituents between 80 and 140 km. In the SPICAV UV range, CO2 possesses a broad signature shortward of 200 nm which allows one to retrieve CO2 concentration and subsequently to deduce atmospheric pressure and temperature profiles in the upper mesosphere and in the thermosphere. The Venusian thermosphere shows excessive variability, with the equivalent of more than three scale heights change in density in less than a few days. No other spectral signature besides that of CO2 and haze particles was expected to appear in SPICAV ultraviolet spectra at this altitude range but a consistent search was undertaken, revealing the presence of aan ozone at 100 km (¡108 cm-3) and of sulfur dioxide above 90 km at a concentration of 0.1 to 1 ppm.

  4. Tumor budding as a novel predictor of occult metastasis in cT2N0 tongue squamous cell carcinoma.

    PubMed

    Sakata, Junki; Yamana, Keisuke; Yoshida, Ryoji; Matsuoka, Yuichiro; Kawahara, Kenta; Arita, Hidetaka; Nakashima, Hikaru; Nagata, Masashi; Hirosue, Akiyuki; Kawaguchi, Sho; Gohara, Shunsuke; Nagao, Yuka; Hiraki, Akimitsu; Shinohara, Masanori; Toya, Ryo; Murakami, Ryuji; Nakayama, Hideki

    2018-06-01

    Occult neck metastasis is an important prognostic factor in patients with tongue squamous cell carcinoma (TSCC) who are deemed clinically negative for neck metastasis. The purpose of this study was to identify predictive factors for occult neck metastasis arising from TSCC and to determine patient prognosis. Ninety-seven patients with cT2N0 TSCC who underwent surgical resection of their primary lesion as initial therapy were enrolled in this retrospective study. Cutoff values for depth of invasion (≥3.3 mm) and the tumor budding score (≥4) were determined using receiver operator characteristic analyses. Univariate and multivariate analyses revealed that a tumor budding score ≥4 is a significant independent predictive factor for the occurrence of occult neck metastasis, which in turn is a significant independent prognostic factor. When evaluating tumor budding, we demonstrated greater interobserver and intraobserver agreement when using immunohistochemical staining for cytokeratin AE1/AE3 than with hematoxylin and eosin staining (HE). We conclude that the evaluation of tumor budding is effective for identifying populations at high risk of occult neck metastasis, which will enable the planning of appropriate therapeutic strategies for patients with cT2N0 TSCC. Furthermore, cytokeratin staining is recommended over HE staining for simpler and more accurate evaluation of tumor budding. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Ground Support Network for Operational Radio Occultation Missions

    NASA Astrophysics Data System (ADS)

    Zandbergen, R.; Enderle, W.; Marquardt, C.; Wollenweber, F.

    2012-04-01

    The EUMETSAT/ESA Metop/EPS GRAS radio occultation mission stands out for its operational nature. From the beginning, EUMETSAT has decided to rely on an operational system for provision of the auxiliary GPS products that are needed in the occultation processing. This system is the GRAS Ground Support Network (GSN), operated in the Navigation Facility of ESOC in Darmstadt, which was first presented at EGU in 2008. The GRAS GSN is driven primarily by timeliness, availability and accuracy requirements. The performance of the GSN, measured on a monthly basis, has not only consistently met these requirements since the start of its operations, but has also been improved through several system enhancements. Currently, an additional service is being delivered on an experimental basis, consisting of a near-real time Navigation Bit Stream product, which will allow the processing of open-loop data, further increasing the scientific return of the GRAS instrument, or any other radio occultation mission using this data. This paper will present the GRAS GSN in its current configuration, and demonstrate its excellent performance in terms of accuracy, availability and timeliness. The application of the bit stream data will be shown. Some future evolution perspectives of the GRAS GSN will also be addressed. It will be demonstrated that the GRAS GSN has the potential of serving also other present and future radio occultation missions.

  6. [Occult hepatitis B virus infection in normal population, Xiamen].

    PubMed

    He, Shuizhen; Su, Chenghao; Shen, Litong; Niu, Jianjun

    2015-02-01

    To investigate the prevalence of occult HBV infection in the normal population in Xiamen. 4 437 registered permanent residents, aged 1-59 years old, were selected in Xiamen using stratified random sampling method from September to October in 2006. Serum samples were obtained, the basic characteristics, inoculation of HBV vaccine, and liver disease were surveyed. The serum samples were tested five HBV seroimmunological markers. The HBsAg-negative specimens were subjected to HBV-DNA detection by nested PCR targeting for multiple gene segments. The amplified products were sequenced and the sequence was used for determination of HBV genotype and mutation analysis of amino acids located in HBsAg "a" epitope. Subjects with serum detectable HBV-DNA and negative result of HBsAg were considered as occult HBV infection. Among the 4 437 subjects, 482 individuals were observed HBsAg positive and 3 944 were observed negative. Of the 3 955 HBsAg- negative specimens, 27 occult HBV infections were determined with the positive rate of 0.68% (27/3 955). There were 16 samples with genotype B and 11 with genotype C. 3 types of amino acid (AA) mutation (M133T, T140I, G145R) that influence "a" epitope conformation were observed in 9 subjects with occult HBV infection. S region was successfully sequenced in 312 of the 482 HBsAg positive samples. In subjects with occult HBV infection, the infection rate of genotype C HBV (40.74%, 11/27), inoculation rate of HBV vaccine (62.96%, 17/27), positive rate of HBsAb (51.85%, 14/27), and mutation rate of critical amino acid of "a" epitope (33.33%, 9/27) were higher than HBsAg positive individuals (22.76% (71/312), 13.78% (43/312),0.32% (1/312),0.99% (31/312), respectively), and all the difference were significant (χ(2) = 4.29, 41.26, 156.00, 13.07, respectively, and P value = 0.038, <0.001, <0.001, <0.001, respectively). While the average age in subjects with occult HBV infection (18.3 ± 16.2) were lower than that in HBsAg positive infection (34.4 ± 11.6), and the difference was significant (t = 6.67, P < 0.001). The reactive rate of HBeAb (11.11%, 3/27) and HBcAb (62.96%, 17/27) in subjects with occult HBV infection were lower than that in HBsAg positive infection (74.36% (232/312), 98.40% (307/312)), and the difference were significant (χ(2) = 46.74, 73.78, respectively, and P value <0.001, <0.001, respectively). In normal population in Xiamen, the infection rate of genotype C, the positive rate of HBsAb, the HBV vaccination rate, and the key AA mutation rate in "a" epitope are significantly higher in occult HBV infection than in HBsAg positive infection, and the age, the positive rate of HBeAb and HBcAb are significantly lower.

  7. The Lunar Occultation Explorer (LOX): Establishing the Moon as a Platform for Next-Generation Nuclear Astrophysics Investigations

    NASA Astrophysics Data System (ADS)

    Miller, R. S.; Ajello, M.; Beacom, J. F.; Bloser, P. F.; Burrows, A.; Errando, M.; Goldsten, J. O.; Hartmann, D.; Hoeflich, P.; Hungerford, A.; Lawrence, D. J.; Leary, J. C.; Leising, M. D.; Milne, P.; Peplowski, P. N.; The, L.-S.

    2018-02-01

    The Lunar Occultation Explorer (LOX) is a paradigm shift that will leverage the power of a new observational paradigm to transform our understanding of the nuclear cosmos (0.1-10 MeV) and establish the Moon as a platform for astrophysics.

  8. Construction of a photometer to detect stellar occultations by outer solar system bodies for the Whipple mission concept

    NASA Astrophysics Data System (ADS)

    Kraft, Ralph P.; Kenter, Almus T.; Alcock, Charles; Murray, Stephen S.; Loose, Markus; Gauron, Thomas; Germain, Gregg; Peregrim, Lawrence

    2014-08-01

    The Whipple mission was a proposal submitted to the NASA Discovery AO in 2010 to study the solid bodies of the Kuiper Belt and Oort Cloud via a blind occultation survey. Though not accepted for flight, the proposal was awarded funding for technology development. Detecting a significant number of Trans Neptunian Objects (TNOs) via a blind occultation survey requires a low noise, wide field of view, multi object differential photometer. The light curve decrement is typically a few percent over timescales of tenths of seconds or seconds for Kuiper Belt and Oort cloud objects, respectively. To obtain a statistically interesting number of detections, this photometer needs to observe many thousands of stars over several years since the rate of occultation for a single star given the space density of the TNOs is low. The light curves from these stars must be monitored with a sensor with a temporal resolution of rv 25-50 ms and with a read noise of< 20 e- rms. Since these requirements are outside the capability of CCDs, the Whipple mission intends to use Teledyne H2RG HyViSI Silicon Hybrid CMOS detectors operating in "window" read mode. The full Whipple focal plane consists of a 3x3 array of these sensors, with each sensor comprised of 1024x 1024 36/μm pixels. Combined with the telescope optic, the Whipple focal plane provides a FOV of rv36 deg2 . In operation, each HyViSI detector, coupled to a Teledyne SIDECAR ASIC, monitors the flux from 650 stars at 40 Hz. The ASIC digitizes the data at the required cadence and an FPGA provides preliminary occultation event selection. The proposed 2010 Whipple mission utilized a spacecraft in a a "drift-away" orbit which signifi­ cantly limited the available telemetry data rate. Most of the light curve processing is required to be on-board the satellite so only candidate occultation events are telemetered to the ground. Occul­ tation light curves must be processed in real time on the satellite by an Field Programmable Gate Array (FPGA). A simple, real time band pass filter, called the Equivalent Width (EW) algorithm, has been instantiated in the FPGA. This EW filter selects for telemetry only those occultation event light curves that differed significantly from noise. As part of our technology development program, a key facet of the proposed Whipple focal plane was constructed and operated in our laboratory consisting of a single HyViSI H2RG sensor, a Teledyne SIDECAR ASIC, and a flight-like Virtex-5 FPGA. In order to fully demonstrate the capabilities of this photometer, we also made a occultation light-curve simulator. The entire system can generate simulated occultation light curves, project them onto an H2RG sensor, read out the sensor in windowing mode at 40 Hz, pass the data to an FPGA that continuously monitors the light curves and dumps candidate occultation events to our simulated Ground Support Equipment (GSE). In this paper, we summarize the technical capabilities of our system, present sample data, and discuss how this system will be used to support our proposal effort for the next Discovery round.

  9. Occult Carbon Monoxide Poisoning

    PubMed Central

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells. PMID:3825110

  10. Occult carbon monoxide poisoning.

    PubMed

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  11. Occult central venous stenosis leading to airway obstruction after subtotal parathyroidectomy.

    PubMed

    Meiklejohn, Duncan A; Chan, Dylan K; Lalakea, M Lauren

    2016-07-01

    Subtotal parathyroidectomy may be indicated in patients with chronic renal failure and tertiary hyperparathyroidism, a population at increased risk for central venous stenosis (CVS) due to repeated vascular access. Here we report a case of complete upper airway obstruction precipitated by subtotal parathyroidectomy with ligation of anterior jugular vein collaterals in a patient with occult CVS. This case demonstrates a previously unreported risk of anterior neck surgery in patients with chronic renal failure. We present a review of the literature and discuss elements of the history and physical examination suggestive of occult CVS, with additional workup proposed for appropriate cases. Recommendations are discussed for perioperative and postoperative care in patients at increased risk for CVS.

  12. The occultation of 28 Sgr by Saturn - Saturn pole position and astrometry

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.; Porco, C. C.; Hunten, D. M.; Rieke, G. H.; Rieke, M. J.; Mccarthy, D. W.; Haemmerle, V.; Clark, R.; Turtle, E. P.; Haller, J.

    1993-01-01

    Saturn's ring plane-defined pole position is presently derived from the geometry of Saturn's July 3, 1989 occultation of 28 Sgr, as indicated by the timings of 12 circular edges in the Saturn C-ring as well as the edges of the Encke gap and the outer edge of the Keeler gap. The edge timings are used to solve for the position angle and opening angle of the apparent ring ellipses; the internal consistency of the data set and the redundancy of stations indicates an absolute error of the order of 5 km. The pole position thus obtained is consistent with the pole and ring radius scale derived from Voyager occultation observations.

  13. Unsuccesfull occultation observation of stars by asteroids

    NASA Astrophysics Data System (ADS)

    Gaina, Alex; Maley, Paul D.

    2010-12-01

    A report is given about an attempt to observe occultations of stars HIP 7268 and TYC1868-02234-01 by asteroids Tisiphone and Thisbe on 3 november 2010 in Chisinau, The Republic of Moldova, which was placed very close to the central line of the occultations in spite of. The main cause of the insucces was weather. Few days before a cyclon developed above the Black Sea, while above the Western Europe, including Greece the sky was covered during many days. Some critics are made concerning the preparation of astronomical facilities in the Republic of Moldova for succesfull observations. The meteo conditions in Lozova-Ciuciuleni were better, but bad, than in other parts of the Republic of Moldova.

  14. Serial magnetic resonance imaging findings in subarachnoid hemorrhage due to an initially angiographically occult type II spinal aneurysm: Case report.

    PubMed

    Kogan, Michael; Morr, Simon; Siddiqui, Adnan H

    2017-04-28

    Spinal aneurysms are rare causes of spontaneous subarachnoid hemorrhage. We present an unusual, initially occult, case of an upper thoracic intradural extramedullary isolated aneurysm arising from the T2 intercostal-radicular circulation that was initially angiographically occult but was discovered due to unique, albeit nonspecific, magnetic resonance imaging findings of spinal cord T2 hyperintensity and contrast enhancement that were noted to progress with a clinical picture of ictal rehemorrhage. Repeat spinal angiography revealed a spinal aneurysm that was treated surgically. In cases of sufficient clinical suspicion and nonspecific imaging findings, continued vigilance is advised in seeking an underlying pathoanatomic etiology.

  15. Dwarfism, occult spinal dysraphism, and presacral myxopapillary ependymoma with an epidermoid cyst in a child.

    PubMed

    Tubbs, R S; Kelly, D R; Mroczek-Musulman, E C; Braune, K; Reddy, A; Georgeson, K; Grabb, P A; Oakes, W J

    2005-03-01

    The authors present a case of a child with dwarfism that was noted to be developmentally delayed. Imaging revealed atlantoaxial instability, occult spinal dysraphism, and a presacral mass. Histopathology of the presacral lesion was that of a myxopapillary ependymoma with epidermoid cyst. We believe this to be the first report in the extant medical literature of this constellation of findings in the same patient. However, there are rare reports indicating a possible association of occult spinal dysraphism and the simultaneous occurrence of spinal ependymomas. Further case reports are necessary to discern whether these pathological entities are true low rate associations that the clinician should consider in their evaluation of these patients.

  16. A new method to analyze UV stellar occultation data

    NASA Astrophysics Data System (ADS)

    Evdokimova, D.; Baggio, L.; Montmessin, F.; Belyaev, D.; Bertaux, J.-L.

    2017-09-01

    In this paper we present a new method of data processing and a classification of different types of stray light at SPICAV UV stellar occultations. The method was developed on a basis of Richardson-Lucy algorithm including: (a) deconvolution process of measured star light and (b) separation of extra emissions registered by the spectrometer.

  17. Past and future of radio occultation studies of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Eshleman, Von R.; Hinson, David P.; Tyler, G. Leonard; Lindal, Gunnar F.

    1987-01-01

    Measurements of radio waves that have propagated through planetary atmospheres have provided exploratory results on atmospheric constituents, structure, dynamics, and ionization for Venus, Mars, Titan, Jupiter, Saturn, and Uranus. Highlights of past results are reviewed in order to define and illustrate the potential of occultation and related radio studies in future planetary missions.

  18. Carbohydrate Metabolism in Submariner Personnel

    DTIC Science & Technology

    1983-06-01

    results are considered indicative of prediabetes or occult diabetes (also called diabetes in situ), the earliest detectable phase of diabetes mellitus...60 uU < 100 uU III. OCCULT OR PREDIABETES WILICERSOt4 PT’ INSUL1N PA TERN 0 POINTS Normal insulin peak- delayed return 2 + 3 hr total > 100 uU 0

  19. Occult hemoglobin as an indicator of impingement stress in fishes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-01-01

    During the process of impingement on cooling system intake screens, fish may be subject to different types of stress, the total of which often results in the death of individual fish. This report assesses the use of occult hemoglobin in fish demand mucus as an indicator of impingement stress. (ACR)

  20. Computed tomography guided localization of clinically occult breast carcinoma-the ''N'' skin guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopans, D.B.; Meyer, J.E.

    1982-10-01

    Standard computed tomography (CT) can be used for the three-dimensional localization of clinically occult suspicious breast lesions whose exact position cannot be determined by standard mammographic views. A method is described that facilitates accurate preoperative needle localization using CT guidance, once the position of these lesions is defined.

  1. Counseling the Occult-Involved Student: Guidelines and Suggestions.

    ERIC Educational Resources Information Center

    Carmichael, Karla D.

    1993-01-01

    Contends that counselors working with public school students needs to be aware of the four main levels of involvement in the occult (fun-and-games, dabblers, serious involvement, and criminal involvement). Each of the four levels is described, warning signs are identified, and the counselor's role is explained as one of support and prevention. (NB)

  2. Verifying occulter deployment tolerances as part of NASA's technology development for exoplanet missions

    NASA Astrophysics Data System (ADS)

    Kasdin, N. J.; Lisman, D.; Shaklan, S.; Thomson, M.; Webb, D.; Cady, E.; Marks, G. W.; Lo, A.

    2013-09-01

    An external occulter is a satellite employing a large screen, or starshade, that flies in formation with a spaceborne telescope to provide the starlight suppression needed for detecting and characterizing exoplanets. Among the advantages of using an occulter are the broadband allowed for characterization and the removal of light before entering the observatory, greatly relaxing the requirements on the telescope and instrument. In support of NASA's Exoplanet Exploration Program and the Technology Development for Exoplanet Missions (TDEM), we recently completed a 2 year study of the manufacturability and metrology of starshade petals. In this paper we review the results of that successful first TDEM which demonstrated an occulter petal could be built and measured to an accuracy consistent with close to 10-10 contrast. We then present the results of our second TDEM to demonstrate the next critical technology milestone: precision deployment of the central truss and petals to the necessary accuracy. We show the deployment of an existing deployable truss outfitted with four sub-scale petals and a custom designed central hub.

  3. An upper limit on Pluto's ionosphere from radio occultation measurements with New Horizons

    NASA Astrophysics Data System (ADS)

    Hinson, D. P.; Linscott, I. R.; Strobel, D. F.; Tyler, G. L.; Bird, M. K.; Pätzold, M.; Summers, M. E.; Stern, S. A.; Ennico, K.; Gladstone, G. R.; Olkin, C. B.; Weaver, H. A.; Woods, W. W.; Young, L. A.; New Horizons Science Team

    2018-06-01

    On 14 July 2015 New Horizons performed a radio occultation (RO) that sounded Pluto's neutral atmosphere and ionosphere. The solar zenith angle was 90.2° (sunset) at entry and 89.8° (sunrise) at exit. We examined the data for evidence of an ionosphere, using the same method of analysis as in a previous investigation of the neutral atmosphere (Hinson et al., 2017). No ionosphere was detected. The measurements are more accurate at occultation exit, where the 1-sigma sensitivity in integrated electron content (IEC) is 2.3 × 1011 cm-2. The corresponding upper bound on the peak electron density at the terminator is about 1000 cm-3. We constructed a model for the ionosphere and used it to guide the analysis and interpretation of the RO data. Owing to the large abundance of CH4 at ionospheric heights, the dominant ions are molecular and the electron densities are relatively small. The model predicts a peak IEC of 1.8 × 1011 cm-2 for an occultation at the terminator, slightly smaller than the threshold of detection by New Horizons.

  4. Changes in Pluto's Atmosphere Revealed by Occultations

    NASA Astrophysics Data System (ADS)

    Sicardy, Bruno; Widemann, Thomas; Lellouch, Emmanuel; Veillet, Christian; Colas, Francois; Roques, Francoise; Beisker, Wolfgang; Kretlow, Mike; Cuillandre, Jean-Charles; Hainaut, Olivier

    After the discovery and study of Pluto's tenuous atmosphere in 1985 and 1988 with stellar occultations 14 years were necessary before two other occultations by the planet could be observed on 20 July 2002 and 21 August 2002 from Northern Chile with a portable telescope and from CFHT in Hawaii respectively. These occultations reveal drastric changes in Pluto's nitrogen atmosphere whose pressure increased by a factor two or more since 1988. In spite of an increasing distance to the Sun (and a correlated decrease of solar energy input at Pluto) this increase can be explained by the fact that Pluto's south pole went from permanent darkness to permanent illumination between 1988 and 2002. This might cause the sublimation of the south polar cap and the increase of pressure which could go on till 2015 according to current nitrogen cycle models. Furthermore we detect temperature contrasts between the polar and the equatorial regions probed on Pluto possibly caused by different diurnally averaged insolations at those locations. Finally spikes observed in the light curves reveal a dynamical activity in Pluto's atmosphere.

  5. Mirages and the nature of Pluto's atmosphere

    NASA Technical Reports Server (NTRS)

    Stansberry, J. A.; Lunine, J. I.; Hubbard, W. B.; Yelle, R. V.; Hunten, D. M.

    1994-01-01

    We present model occultation lightcurves demonstrating that a strong thermal inversion layer at the base of Pluto's stratosphere can reproduce the minimum flux measured by the Kuiper Airborne Observatory (KAO) during the 1988 occultation of a star by Pluto. The inversion layer also forms the occultation equivalent of a mirage at a radius of 1198 km, which is capable of hiding tropospheres of significant depth. Pluto's surface lies below 1198 km, its radius depending on the depth of the troposphere. We begin by computing plausible temperature structures for Pluto's lower atmosphere, constrained by a calculation of the temperature of the atmosphere near the surface. We then trace rays from the occulted star through the model atmosphere, computing the resultant bending of the ray. Model light curves are obtained by summing the contribution of individual rays within the shadow of Pluto on Earth. We find that we can reproduce the KAO lightcurve using model atmospheres with a temperature inversion and no haze. We have explored models with tropospheres as deep as 40 km (implying a Pluto radius of 1158 km) that reproduce the suite of occultation data. Deeper tropospheres can be fitted to the data, but the mutual event radius of 1150 km probably provides a lower bound. If Pluto has a shallow or nonexistent troposphere, its density is consistent with formation in the solar nebula with modest water loss due to impact ejection. If the troposhere is relatively deep, implying a smaller radius and larger density, significant amounts of water loss are required.

  6. Pluto occultation on 2015 June 29 UTC with central flash and atmospheric spikes just before the New Horizons flyby

    NASA Astrophysics Data System (ADS)

    Pasachoff, Jay M.; Babcock, Bryce A.; Durst, Rebecca F.; Seeger, Christina H.; Levine, Stephen E.; Bosh, Amanda S.; Person, Michael J.; Sickafoose, Amanda A.; Zuluaga, Carlos A.; Kosiarek, Molly R.; Abe, Fumio; Nagakane, Masayuki; Suzuki, Daisuke; Tristram, Paul J.; Arredondo, Anicia

    2017-11-01

    We observed the occultation by Pluto of a 12th magnitude star, one of the two brightest occultation stars ever in our dozen years of continual monitoring of Pluto's atmosphere through such studies, on 2015 June 29 UTC. At the Univ. of Canterbury Mt. John Observatory (New Zealand), under clear skies throughout, we used a POETS frame-transfer CCD at 10 Hz with GPS timing on the 1-m McLellan telescope as well as an infrared camera on an 0.6-m telescope and three-color photometry at a slower cadence on a second 0.6-m telescope. At the Auckland Observatory, we used a POETS and a PICO on 0.5-m and 0.4-m telescopes, with 0.4 s and 2 s cadences, respectively, obtaining ingress observations before clouds moved in. The Mt. John light curves show a central flash, indicating that we were close to the center of the occultation path. Analysis of our light curves show that Pluto's atmosphere remains robust. The presence of spikes at both sites in the egress and ingress shows atmospheric layering. We coordinated our observations with aircraft observations (Bosh et al., 2017) with the Stratospheric Observatory for Infrared Astronomy (SOFIA). Our chords helped constrain the path across Pluto that SOFIA saw. Our ground-based and airborne stellar-occultation effort came only just over two weeks of Earth days and two Pluto days before the flyby of NASA's New Horizons spacecraft.

  7. Results from the 2010 Feb 14 and July 4 Pluto Occultations

    NASA Astrophysics Data System (ADS)

    Young, Leslie; Sicardy, B.; Widemann, T.; Brucker, M. J.; Buie, M. W.; Fraser, B.; Van Heerden, H.; Howell, R. R.; Lonergan, K.; Olkin, C. B.; Reitsema, H. J.; Richter, A.; Sepersky, T.; Wasserman, L. H.; Young, E. F.

    2010-10-01

    The Portable High-speed Occultation Telescope (PHOT) group observed two occultations by Pluto in 2010. The first, of a I=9.3 magnitudue star on 2010 Feb 14, was organized by the Meudon occultation group, with the PHOT group as collaborators. For this bright but low-elevation event, we deployed to three sites in Europe: Obs. Haute Provence, France (0.8-m; L. Young, H. Reitsema), Leopold Figl, Austria (1.5-m; E. Young), and Apline Astrovillage, Lu, Switzerland (0.36-m; C. Olkin, L. Wasserman). We obtained a lightcurve at Lu under clear conditions, which will be combined with two other lightcurves from the Meudon group, from Sisteron and Pic du Midi, France. We observed the second Pluto occultation, of a I=13.2 star on 2010 July 4 UT, from four sites in South Africa: with our portable telescope near Upington (0.36-m; M. Buie, L. Wasserman), the Boyden telescope in Bloemfontein (1.5-m; L. Young, M. Brucker), the Innes telescope in Johannesburg (0.67-m; T. Sepersky, B. Fraser), and the telescope at Aloe Ridge north of Johannesburg (0.62-m; R. Howell, K. Lonergan, A. Richter). Upington was cloudy, Boyden had heavy scattered clouds, and Innes suffered from haze and telescope mechanical problems. A lightcurve was obtained from Aloe Ridge under clear conditions. Data was also obtained by Karl-Ludwig Bath & Thomas Sauer at Hakos, Namibia and by Berto Monard of ASSA near Pretoria, South Africa. The length of the Aloe Ridge chord suggests it is nearly central. These observations give us four contiguous years in which we observed one or more Pluto occultations, providing constraints on the seasonal evolution of Pluto's atmosphere. Thanks are due to Marcelo Assafin and Jim Elliot for sharing predictions prior to the July event. This work was supported, in part, by NASA PAST NNX08A062G.

  8. Probing the Martian Atmosphere with MAVEN/IUVS Stellar Occultations

    NASA Astrophysics Data System (ADS)

    Gröller, H.; Yelle, R. V.; Koskinen, T.; Montmessin, F.; Lacombe, G.; Schneider, N. M.; Deighan, J.; Stewart, I. F.; Jain, S.; Chaffin, M.; Crismani, M. M. J.; Stiepen, A.; Lefèvre, F.; McClintock, B.; Clarke, J. T.; Holsclaw, G.; Mahaffy, P. R.; Bougher, S. W.; Jakosky, B. M.

    2015-12-01

    We present the first results of FUV and MUV stellar occultations taken with the Imaging UltraViolet Spectrometer (IUVS) onboard MAVEN. The FUV and MUV channels of the IUVS together cover the spectral range from 115 to 330 nm. The first two campaigns were executed during March 24 and March 26, 2015, and during May 17 and May 18, 2015, respectively. So far 13 occultations could be used to retrieve CO2 and O2 number densities in the altitude range between 100 and 150 km from the first occultation campaign. From the second occultation campaign number densities for CO2, O3, and aerosols were obtained between 20 and 100 km altitude. Temperature profiles for the same altitude ranges were calculated by applying the constraint of hydrostatic equilibrium to the CO2 densities. With a cadence of 2.6 s, including a 2.0 s integration time, the altitude resolution of the density and temperature profiles is between 1.5 and 4.5 km, depending on the geometry of the particular occultation. The retrieved density profiles of CO2 and O2 agree with previous measurements obtained by the Mars Express SPICAM instrument and by Viking 1 and 2. The corresponding O2 mixing ratios range from 1 to 5 x 10-3, also in agreement with previous observations. The temperatures that we retrieved agree with the models in the Mars Climate Database (MCD) between 10-2 and 10-4 Pa. At lower pressures, however, the measured temperatures are on average 70 K to 100 K cooler than the temperatures predicted by the MCD. This is because the model temperatures increase steadily with altitude above the mesopause whereas the observed temperatures decrease at pressures less than 3.5 x 10-5 Pa, reaching a minimum near 7 x 10-6 Pa. The large differences between the MCD and our results indicate that global models of thermal structure around the mesopause need to be revised.

  9. Occult Hepatitis B virus infection in previously screened, blood donors in Ile-Ife, Nigeria: implications for blood transfusion and stem cell transplantation.

    PubMed

    Olotu, Amadin A; Oyelese, Adesola O; Salawu, Lateef; Audu, Rosemary A; Okwuraiwe, Azuka P; Aboderin, Aaron O

    2016-05-05

    Hepatitis B virus (HBV) transmission through blood transfusion is reduced by screening for hepatitis B surface antigen (HBsAg). However this method cannot detect the presence of occult hepatitis B virus infection. This study sought to determine the prevalence of occult hepatitis B virus infection among blood donors in Ile-Ife, Nigeria. For the first time in Nigeria we employed an automated real-time PCR- method to investigate the prevalence of occult HBV in blood donors. Blood donors screened with HBsAg immunochromatographic rapid test kits at the blood transfusion units of two hospitals and found to be negative were recruited into the study. Questionnaires to elicit risk factors for HBV infection were administered and then 10 ml of blood was collected from each donor. Plasma samples obtained from these HBsAg negative blood donors were screened again for HBsAg using an enzyme-linked immunosorbent assay (ELISA) method, and those found negative were screened for the presence of total antibody to the HBV core antigen (anti-HBc) using ELISA method. Those positive to anti-HBc were then tested for HBV DNA, using an automated real-time PCR method. Five hundred and seven blood donors found HBsAg negative by immunochromatographic rapid test kits at both blood transfusion units, were tested for HBsAg using ELISA and 5 (1 %) were HBsAg positive. The 502 found negative were tested for anti-HBc and 354 (70.5 %) were found positive implying previous exposure to HBV and 19 (5.4 %) of the 354 anti-HBc positive had HBV DNA signifying occult HBV infection. No risk factors were found to be associated with the presence of HBV DNA among those who tested positive. Occult HBV infection exists in blood donors in Ile-Ife, Nigeria and the use of HBsAg alone for screening prospective donors will not eliminate the risk of HBV transmission in blood transfusion or stem cell transplantation.

  10. Prognostic significance of extranodal extension in head and neck squamous cell carcinoma cN0 patients with occult metastatic neck nodes.

    PubMed

    Lop, Joan; Rigó, Antoni; Codina, Alberto; de Juan, Julia; Quer, Miquel; León, Xavier

    Extranodal extension in nodal metastases is an independent adverse prognostic factor in head and neck squamous cell carcinoma patients. However, few studies specifically address the subgroup of patients with no clinical evidence of nodal disease. We retrospectively analysed data from 348 head and neck squamous cell carcinoma patients without any previous treatment and lacking clinical or radiological evidence of neck node metastases during the initial workup, treated with an elective neck dissection between 1992-2014. The incidence of occult metastatic neck nodes with extranodal extension and the impact of extranodal extension in survival were evaluated. The proportion of patients with occult neck node metastases was 33%. Of these, 23.5% had at least one metastatic neck node with extranodal extension. There were significant differences in the disease-specific survival rate according to neck node status. Five-year disease-specific survival for patients without histopathological metastases was 90%, for patients with occult neck node metastases without extranodal extension it was 71.2%, and for patients with occult neck node metastases with extranodal extension it was 25.9% (P=.0001). The multivariate analysis revealed that the presence of occult node metastases with extranodal extension was the factor with strongest impact on survival. The inclusion of the extranodal extension as a criterion of histopathological evaluation in the 8th TNM classification edition improves the prognostic capacity compared to previous TNM editions. Appearance of metastatic neck nodes with extranodal extension is an adverse prognostic factor in head and neck squamous cell carcinoma patients without clinical evidence of regional disease during the initial workup of the tumour. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  11. Characteristics of escape mutations from occult hepatitis B virus infected patients with hematological malignancies in South Egypt.

    PubMed

    Elkady, Abeer; Iijima, Sayuki; Aboulfotuh, Sahar; Mostafa Ali, Elsayed; Sayed, Douaa; Abdel-Aziz, Nashwa M; Ali, Amany M; Murakami, Shuko; Isogawa, Masanori; Tanaka, Yasuhito

    2017-03-28

    To investigate the prevalence and virological characteristics of occult hepatitis B virus (HBV) infections in patients with hematological malignancies in South Egypt. Serum samples were collected from 165 patients with hematological malignancies to monitor titers of HBV DNA, hepatitis B surface antigen (HBsAg), and antibodies to HBV core (anti-HBc) and surface antigens. Serum samples negative for HBsAg and positive for anti-HBc were subjected to nucleic acid extraction and HBV DNA detection by real-time polymerase chain reaction. DNA sequences spanning the S region were analyzed in cases with occult HBV infection. In vitro comparative study of constructed 1.24-fold wild type and S protein mutant HBV genotype D clones was further performed. HBV DNA was detected in 23 (42.6%) of 54 patients with hematological malignancies who were HBsAg negative, but anti-HBc positive, suggesting the presence of occult HBV infection. The complete HBV genome was retrieved from 6 occult HBV patients, and P120T and S143L were detected in 3 and 2 cases, respectively. Site directed mutagenesis was done to produce 1.24-fold genotype D clones with amino acid mutations T120 and L143. The in vitro analyses revealed that a lower level of extracellular HBsAg was detected by chemiluminescence enzyme immunoassay (CLEIA) with the clone containing T120 mutation, compared with the wild type or the clone with S143L mutation despite the similar levels of extracellular and intracellular HBsAg detected by Western blot. Southern blot experiments showed that the levels of intracellular HBV DNA were not different between these clones. Occult HBV infection is common in patients with hematological malignancies and associated with P120T and S143L mutations. 120T mutation impairs the detection of HBsAg by CLEIA.

  12. Characteristics of escape mutations from occult hepatitis B virus infected patients with hematological malignancies in South Egypt

    PubMed Central

    Elkady, Abeer; Iijima, Sayuki; Aboulfotuh, Sahar; Mostafa Ali, Elsayed; Sayed, Douaa; Abdel-Aziz, Nashwa M; Ali, Amany M; Murakami, Shuko; Isogawa, Masanori; Tanaka, Yasuhito

    2017-01-01

    AIM To investigate the prevalence and virological characteristics of occult hepatitis B virus (HBV) infections in patients with hematological malignancies in South Egypt. METHODS Serum samples were collected from 165 patients with hematological malignancies to monitor titers of HBV DNA, hepatitis B surface antigen (HBsAg), and antibodies to HBV core (anti-HBc) and surface antigens. Serum samples negative for HBsAg and positive for anti-HBc were subjected to nucleic acid extraction and HBV DNA detection by real-time polymerase chain reaction. DNA sequences spanning the S region were analyzed in cases with occult HBV infection. In vitro comparative study of constructed 1.24-fold wild type and S protein mutant HBV genotype D clones was further performed. RESULTS HBV DNA was detected in 23 (42.6%) of 54 patients with hematological malignancies who were HBsAg negative, but anti-HBc positive, suggesting the presence of occult HBV infection. The complete HBV genome was retrieved from 6 occult HBV patients, and P120T and S143L were detected in 3 and 2 cases, respectively. Site directed mutagenesis was done to produce 1.24-fold genotype D clones with amino acid mutations T120 and L143. The in vitro analyses revealed that a lower level of extracellular HBsAg was detected by chemiluminescence enzyme immunoassay (CLEIA) with the clone containing T120 mutation, compared with the wild type or the clone with S143L mutation despite the similar levels of extracellular and intracellular HBsAg detected by Western blot. Southern blot experiments showed that the levels of intracellular HBV DNA were not different between these clones. CONCLUSION Occult HBV infection is common in patients with hematological malignancies and associated with P120T and S143L mutations. 120T mutation impairs the detection of HBsAg by CLEIA. PMID:28396718

  13. New Atmospheric Observations from the Airborne GNSS Instrument System for Multistatic and Occultation Sensing (GISMOS)

    NASA Astrophysics Data System (ADS)

    Haase, J. S.; Xie, F.; Muradyan, P.; Garrison, J. L.; Lulich, T.; Voo, J.; Larson, K. M.

    2008-12-01

    The Airborne GNSS Instrument System for Multistatic and Occultation Sensing (GISMOS) was deployed on the NCAR HIAPER (High-performance Instrumented Airborne Platform for Environmental Research) aircraft to make atmospheric observations over the Gulf of Mexico coastal region in February 2008. The objective of the measurements was to test the performance of the system in comparisons with radiosonde profiles and dropsonde profiles that were also collected during the field campaign. The airborne GNSS radio occultation measures of GNSS signals from satellites that are setting or rising behind the Earth's limb relative to the receiver on board an aircraft. High-gain side-looking antennas and a 10MHz GPS Recording System that records the raw RF signal make this set of instrumentation unique, and especially adapted for open-loop tracking observations in the lower atmosphere. Measurements of the amount of refraction in the signal ray paths are inverted using an Abel transform procedure to retrieve a profile of refractivity, which depends on atmospheric pressure, temperature and relative humidity. The airborne geometry, in contrast to the space- borne satellite occultation geometry, is affected by a large drift in the tangent point location, that is the location of the closest point to the Earth surface, as the ray path descends in the atmosphere. Therefore plans for the validation campaign included releasing dropsondes in the plane of the line of sight of the satellite-receiver occultation geometry in order to study this effect. Careful timing and location of the flight path was used to coordinate occultation times with operational and supplementary radiosonde launches. A total of 6 days of balloon sounding data were collected with 20 dropsondes and 28 supplementary radiosonde profiles. A discussion of the technical performance of the system will be presented, which describes the signal characteristics and antenna performance. Preliminary results on the quality of retrieved refractivity profiles will also be shown.

  14. Validation of ionospheric electron density profiles inferred from GPS occultation observations of the GPS/MET experiment

    NASA Astrophysics Data System (ADS)

    Kawakami, Todd Mori

    In April of 1995, the launch of the GPS Meteorology Experiment (GPS/MET) onboard the Orbview-1 satellite, formerly known as Microlab-1, provided the first technology demonstration of active limb sounding of the Earth's atmosphere with a low Earth orbiting spacecraft utilizing the signals transmitted by the satellites of the Global Positioning System (GPS). Though the experiment's primary mission was to probe the troposphere and stratosphere, GPS/MET was also capable of making radio occultation observations of the ionosphere. The application of the GPS occultation technique to the upper atmosphere created a unique opportunity to conduct ionospheric research with an unprecedented global distribution of observations. For operational support requirements, the Abel transform could be employed to invert the horizontal TEC profiles computed from the L1 and L2 phase measurements observed by GPS/MET into electron density profiles versus altitude in near real time. The usefulness of the method depends on how effectively the TEC limb profiles can be transformed into vertical electron density profiles. An assessment of GPS/MET's ability to determine electron density profiles needs to be examined to validate the significance of the GPS occultation method as a new and complementary ionospheric research tool to enhance the observational databases and improve space weather modeling and forecasting. To that end, simulations of the occultation observations and their inversions have been conducted to test the Abel transform algorithm and to provide qualitative information about the type and range of errors that might be experienced during the processing of real data. Comparisons of the electron density profiles inferred from real GPS/MET observations are then compared with coincident in situ measurements from the satellites of Defense Meteorological Satellite Program (DMSP) and ground-based remote sensing from digisonde and incoherent scatter radar facilities. The principal focus of this study is the validation of the electron density profiles inferred from GPS occultation observations using the Abel transform.

  15. Cassini Radio Occultation by Enceladus Plume

    NASA Astrophysics Data System (ADS)

    Kliore, A.; Armstrong, J.; Flasar, F.; French, R.; Marouf, E.; Nagy, A.; Rappaport, N.; McGhee, C.; Schinder, P.; Anabtawi, A.; Asmar, S.; Barbinis, E.; Fleischman, D.; Goltz, G.; Aguilar, R.; Rochblatt, D.

    2006-12-01

    A fortuitous Cassini radio occultation by Enceladus plume occurs on September 15, 2006. The occultation track (the spacecraft trajectory in the plane of the sky as viewed from the Earth) has been designed to pass behind the plume (to pass above the south polar region of Enceladus) in a roughly symmetrical geometry centered on a minimum altitude above the surface of about 20 km. The minimum altitude was selected primarily to ensure probing much of the plume with good confidence given the uncertainty in the spacecraft trajectory. Three nearly-pure sinusoidal signals of 0.94, 3.6, and 13 cm-wavelength (Ka-, X-, and S-band, respectively) are simultaneously transmitted from Cassini and are monitored at two 34-m Earth receiving stations of the Deep Space Network (DSN) in Madrid, Spain (DSS-55 and DSS-65). The occultation of the visible plume is extremely fast, lasting less than about two minutes. The actual observation time extends over a much longer time interval, however, to provide a good reference baseline for potential detection of signal perturbations introduced by the tenuous neutral and ionized plume environment. Given the likely very small fraction of optical depth due to neutral particles of sizes larger than about 1 mm, detectable changes in signal intensity is perhaps unlikely. Detection of plume plasma along the radio path as perturbations in the signals frequency/phase is more likely and the magnitude will depend on the electron columnar density probed. The occultation time occurs not far from solar conjunction time (Sun-Earth-probe angle of about 33 degrees), causing phase scintillations due to the solar wind to be the primary limiting noise source. We estimate a delectability limit of about 1 to 3E16 electrons per square meter columnar density assuming about 100 seconds integration time. Potential measurement of the profile of electron columnar density along the occultation track is an exciting prospect at this time.

  16. Menstrual cycle characteristics of young females with occult primary ovarian insufficiency at initial diagnosis and one-year follow-up with serum amh level and antral follicle count

    PubMed Central

    Guzel, Yilmaz; Aba, Yilda Arzu; Yakin, Kayhan

    2017-01-01

    Occult primary ovarian insufficiency (also known as incipient ovarian failure or diminished ovarian reserve) is defined as serum AMH level ≤1.1ng/mL in women under age 30. Limited data is available regarding the prevalence of occult POI, the preceding menstrual characteristics and its natural course in otherwise healthy young females. We aimed in this prospective observational study to determine the prevalence of occult POI in young females (< age 30) screened with serum AMH measurement; and analyze the patterns of change in their menstruation at initial assessment and one-year follow-up in relation to the changes in ovarian reserve quantitatively assessed with AMH and AFC. 963 young female college students under age 30 voluntarily participated in this study. 43 of them (4.4%) were diagnosed with occult POI as their AMH levels were ≤ 1.1ng/mL. Thirty-eight (83.4%) of them have regular cycles and denied any menstrual irregularity in the last 12 months. This rate was not statistically different from 7.3% of those with AMH>1.1ng/mL who reported at least one abnormal menstrual cycle in the last year (p = 0.36). Cycle length was significantly shorter in females with AMH ≤ 1.1ng/mL compared to those with AMH>1.1ng/mL (25.1±3.2 vs. 31.2±2.8 respectively, p<0.001). Karyotype, FMR-1 mutation analyses and auto-antibody screening returned normal in all. At one-year follow-up AMH, AFC and mean cycle length were further reduced compared to their values at initial assessment. Now, a greater proportion of the participants with occult POI were menstruating regularly at every 21 days compared to the initial evaluation one year ago (39.5% vs. 13.9% respectively, p = 0.013). Twenty-five underwent oocyte cryopreservation. These findings underscore the importance of screening young females with AMH for possible occult POI. It also emphasizes that young females with critically diminished ovarian reserve may continue to menstruate regularly without any characteristic menstrual abnormality other than shortening of cycle length. PMID:29176793

  17. Menstrual cycle characteristics of young females with occult primary ovarian insufficiency at initial diagnosis and one-year follow-up with serum amh level and antral follicle count.

    PubMed

    Guzel, Yilmaz; Aba, Yilda Arzu; Yakin, Kayhan; Oktem, Ozgur

    2017-01-01

    Occult primary ovarian insufficiency (also known as incipient ovarian failure or diminished ovarian reserve) is defined as serum AMH level ≤1.1ng/mL in women under age 30. Limited data is available regarding the prevalence of occult POI, the preceding menstrual characteristics and its natural course in otherwise healthy young females. We aimed in this prospective observational study to determine the prevalence of occult POI in young females (< age 30) screened with serum AMH measurement; and analyze the patterns of change in their menstruation at initial assessment and one-year follow-up in relation to the changes in ovarian reserve quantitatively assessed with AMH and AFC. 963 young female college students under age 30 voluntarily participated in this study. 43 of them (4.4%) were diagnosed with occult POI as their AMH levels were ≤ 1.1ng/mL. Thirty-eight (83.4%) of them have regular cycles and denied any menstrual irregularity in the last 12 months. This rate was not statistically different from 7.3% of those with AMH>1.1ng/mL who reported at least one abnormal menstrual cycle in the last year (p = 0.36). Cycle length was significantly shorter in females with AMH ≤ 1.1ng/mL compared to those with AMH>1.1ng/mL (25.1±3.2 vs. 31.2±2.8 respectively, p<0.001). Karyotype, FMR-1 mutation analyses and auto-antibody screening returned normal in all. At one-year follow-up AMH, AFC and mean cycle length were further reduced compared to their values at initial assessment. Now, a greater proportion of the participants with occult POI were menstruating regularly at every 21 days compared to the initial evaluation one year ago (39.5% vs. 13.9% respectively, p = 0.013). Twenty-five underwent oocyte cryopreservation. These findings underscore the importance of screening young females with AMH for possible occult POI. It also emphasizes that young females with critically diminished ovarian reserve may continue to menstruate regularly without any characteristic menstrual abnormality other than shortening of cycle length.

  18. Sensing Water Vapon via Spacecraft Radio Occultation Observations

    NASA Technical Reports Server (NTRS)

    Kursinski, E. Robert; Hajj, George A.

    2000-01-01

    The radio occultation technique has been used to characterize planetary atmospheres since the 1960's spanning atmospheric pressures from 16 microbars to several bars. In 1988, the use of GPS signals to make occultation observations of Earth's atmosphere was realized by Tom Yunck and Gunnar Lindal at JPL. In the GPS to low-Earth-orbiter limb- viewing occultation geometry, Fresnel diffraction yield a unique combination of high vertical resolution of 100 m to 1 km at long wavelengths (approx. 20 cm) insensitive to particulate scattering which allows routine limb sounding from the lower mesosphere through the troposphere. A single orbiting GPS/GLONASS receiver can observe - 1000 to 1400 daily occultations providing as many daily, high vertical resolution soundings as the present global radiosonde network, but with far more evenly distributed, global coverage. The occultations yield profiles of refractivity as a function of height. In the cold, dry conditions of the upper troposphere and above (T less than 240 K), profiles of density, pressure (geopotential), and temperature can be derived. Given additional temperature information, water vapor can be derived in the midddle and lower troposphere with a unique combination of vertical resolution, global distribution and insensitivity to clouds and precipitation to an accuracy of approx. 0.2 g/kg. At low latitudes, moisture profiles will be accurate to 1-5% within the convective boundary layer and better than 20% below 6 to 7 km. Accuracies of climatological averages should be approx. 0. 1 g/kg limited by the biases in the temperature estimates. To use refractivity to constrain water vapor, knowledge of temperature is required. The simplest approach is to use the temperature field from an analysis such as the 6 hour ECMWF global analysis interpolated to the locations of each occultation. A better approach is to combine the temperature and moisture fields from such an analysis with the occultation refractivity in a weighting scheme based on the errors in each data field. A ID variational combinational approach has been developed at the UKMO. We win present results from both approaches from GPS/MET data taken in June and July 1995 and compare them with the ECMWF global 6 hour moisture analyses which are derived largely from TOVS and radiosonde data. Overall, the atmosphere below the 500 mb level appears somewhat drier in general than the ECNIWF humidity field. A 2-D (latitude vs. height) climatological snapshot derived from a 2-week span of GPS/MET data will be compared to the humidity climatology of Peixoto and Oort derived from radiosonde data from 1963-1973. Differences between the GPS results and Peixoto and Oort may be the signature of a climate trend over the past 30 years.

  19. A photometric study of the hot exoplanet WASP-19b

    NASA Astrophysics Data System (ADS)

    Lendl, M.; Gillon, M.; Queloz, D.; Alonso, R.; Fumel, A.; Jehin, E.; Naef, D.

    2013-04-01

    Context. The sample of hot Jupiters that have been studied in great detail is still growing. In particular, when the planet transits its host star, it is possible to measure the planetary radius and the planet mass (with radial velocity data). For the study of planetary atmospheres, it is essential to obtain transit and occultation measurements at multiple wavelengths. Aims: We aim to characterize the transiting hot Jupiter WASP-19b by deriving accurate and precise planetary parameters from a dedicated observing campaign of transits and occultations. Methods: We have obtained a total of 14 transit lightcurves in the r'-Gunn, I-Cousins, z'-Gunn, and I + z' filters and 10 occultation lightcurves in z'-Gunn using EulerCam on the Euler-Swiss telescope and TRAPPIST. We also obtained one lightcurve through the narrow-band NB1190 filter of HAWK-I on the VLT measuring an occultation at 1.19 μm. We performed a global MCMC analysis of all new data, together with some archive data in order to refine the planetary parameters and to measure the occultation depths in z'-band and at 1.19 μm. Results: We measure a planetary radius of Rp = 1.376 ± 0.046 RJ, a planetary mass of Mp = 1.165 ± 0.068 MJ, and find a very low eccentricity of e = 0.0077-0.0032+0.0068, compatible with a circular orbit. We have detected the z'-band occultation at 3σ significance and measure it to be δFocc,z' = 352 ± 116 ppm, more than a factor of 2 smaller than previously published. The occultation at 1.19 μm is only marginally constrained at δFocc,NB1190 = 1711-726+745 ppm. Conclusions: We show that the detection of occultations in the visible range is within reach, even for 1 m class telescopes if a considerable number of individual events are observed. Our results suggest an oxygen-dominated atmosphere of WASP-19b, making the planet an interesting test case for oxygen-rich planets without temperature inversion. Based on photometric observations made with HAWK-I on the ESO VLT/UT4 (Prog. ID 084.C-0532), EulerCam on the Euler-Swiss telescope and the Belgian TRAPPIST telescope, as well as archive data from the Faulkes South Telescope, CORALIE on the Euler-Swiss telescope, HARPS on the ESO 3.6 m telescope (Prog. ID 084-C-0185), and HAWK-I (Prog. ID 083.C-0377(A)).The photometric time series data in this work are only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/552/A2

  20. Occult Genres and the Certification of Madness in a 19th-Century Lunatic Asylum

    ERIC Educational Resources Information Center

    Berkenkotter, Carol; Hanganu-Bresch, Cristina

    2011-01-01

    Using archival admissions records and case histories of patients at a British asylum from the 1860s to the 1870s, the authors examine the medical certification process leading to the asylum confinement of individuals judged to be "of unsound mind." These institutional texts are, the authors suggest, "occult genres" that…

  1. Finding Terrestrial Planets Using External Occulters

    NASA Technical Reports Server (NTRS)

    Heap, Sara

    2007-01-01

    In order to identify a detected exoplanet as an Earth-like (habitable) planet, we must obtain its spectrum to verify that its atmosphere shows evidence of water vapor. We argue that a regular, optical telescope combined with a large occulter to block light from the star offers the most promising, cost-effective way to detect and characterize exoplanets.

  2. Photometry of occultation candidate stars. I - Uranus 1985 and Saturn 1985-1991

    NASA Technical Reports Server (NTRS)

    French, L. M.; Morales, G.; Dalton, A. S.; Klavetter, J. J.; Conner, S. R.

    1985-01-01

    Photometric observations of five stars to be occulted by the rings around Uranus are presented. The four stars to be occulted by Saturn or its rings during the period 1985-1991 were also observed. The observations were carried out with a CCD detector attached to the Kitt Peak McGraw-Hill 1.30-m telescope. Landolt standards of widely ranging V-I color indices were used to determine the extinction coefficients, transformation coefficients, and zero points of the stars. Mean extinction coefficients are given for each night of observation. K magnitudes for each star were estimated on the basis of the results of Johnson (1967). The complete photometric data set is given in a series of tables.

  3. [Occult medicine in the 20th century: pharmacotherapy by Demeter Georgievitz-Weitzer, known as Surya (1873 - 1949)].

    PubMed

    Helmstädter, Axel

    2011-01-01

    Demeter Georgievitz-Weitzer (1873-1949), called "Surya", Sanskrit for "sun", was an important representative of medical occultism in the first half of the 20th century. He worked as a journal editor and published a 13-volume book series about occult medicine, mainly written by himself. His hypotheses were closely related to the "Lebensreform" movement around 1900. Regarding diagnostics, he relied on astrology, cheiromancy, and clairvoyance, while therapeutics were dominated by diet and spagyric remedies according to Cesare Mattei (1809-1896) and Carl-Friedrich Zimpel (1801-1879). In his later years, he developed his own healing system, initially comprising eight, later only two preparations. Surya remedies were commercially available until the end of the 20th century,

  4. Occult fractures of the knee: tomographic evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apple, J.S.; Martinez, S.; Allen, N.B.

    1983-08-01

    Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans maymore » be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture.« less

  5. The diameter of Pallas from its occultation of SAO 85009

    NASA Technical Reports Server (NTRS)

    Wasserman, L. H.; Millis, R. L.; Franz, O. G.; Bowell, E.; Giclas, H. L.; Martin, L. J.; Elliot, J. L.; Dunham, E.; Mink, D.; White, N. M.

    1979-01-01

    The May 29, 1978, occultation of SAO 85009 by Pallas was observed photoelectrically at seven widely spaced sites. The observations are well represented by an elliptical apparent limb profile having semimajor and semiminor axes of 279.5 + or - 2.9 and 262.7 + or - 4.5 km, respectively. Combining these results with published information on the light curve and rotational pole position, Pallas's mean diameter is found to be 538 + or - 12 km, which yields a mean density for Pallas of 2.8 + or - 0.5 g/cu cm and a visual geometric albedo of 0.103 + or - 0.005. The diameter of Pallas as determined from this occultation is significantly smaller than the values derived by radiometric, polarimetric, and double-image techniques.

  6. Observing Tropospheric Water Vapor by Radio Occultation using the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Kursinski, E. R.; Hajj, G. A.; Hardy, K. R.; Romans, L. J.; Schofield, J. T.

    1995-01-01

    Given the importance of water vapor to weather, climate and hydrology, global humidity observations from satellites are critical. At low latitudes, radio occultation observations of Earth's atmosphere using the Global Positioning System (GPS) satellites allow water vapor profiles to be retrieved with accuracies of 10 to 20% below 6 to 7 km altitude and approx. 5% or better within the boundary layer. GPS observations provide a unique combination of accuracy, vertical resolution (less than or equal to 1 km) and insensitivity to cloud and aerosol particles that is well suited to observations of the lower troposphere. These characteristics combined with the inherent stability of radio occultation observations make it an excellent candidate for the measurement of long term trends.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbiellini, G.; Bastieri, D.; Buson, S.

    Observations of occultations of bright γ-ray sources by the Sun may reveal predicted pair halos around blazars and/or new physics, such as, e.g., hypothetical light dark matter particles—axions. We use Fermi Gamma-Ray Space Telescope (Fermi) data to analyze four occultations of blazar 3C 279 by the Sun on October 8 each year from 2008 to 2011. A combined analysis of the observations of these occultations allows a point-like source at the position of 3C 279 to be detected with significance of ≈3σ, but does not reveal any significant excess over the flux expected from the quiescent Sun. The likelihood ratiomore » test rules out complete transparency of the Sun to the blazar γ-ray emission at a 3σ confidence level.« less

  8. Potential clinical value of PET/CT in predicting occult nodal metastasis in T1-T2N0M0 lung cancer patients staged by PET/CT

    PubMed Central

    Zhou, Xiang; Chen, Ruohua; Huang, Gang; Liu, Jianjun

    2017-01-01

    We assessed the clinical value of 2-fluoro-2-deoxyglucose (18F-FDG) PET/CT imaging for predicting occult nodal metastasis in non-small cell lung cancer (NSCLC) patients. This retrospective study included 54 patients with T1-2N0M0 NSCLC who had undergone 18F-FDG PET/CT before surgery. Occult nodal metastasis was detected in 25.9% (14/54) of the patients. Immunohistochemical analysis revealed that increased glucose transporter 1 expression was associated with occult nodal metastasis, but hexokinase 2 expression was not. Compared to the negative nodal metastasis group, the positive nodal metastasis group was associated with increased maximum standardized uptake value (SUVmax) and tumor size. Multivariate analysis indicated that SUVmax and tumor size were associated with nodal metastasis. Nodal metastasis could be predicted with a sensitivity of 92.9% and a specificity of 55.0% when the SUVmax cutoff was 4.35. When patients were divided into low-risk (tumor size ≤ 2.5 cm and SUVmax ≤ 4.35), moderate-risk (tumor size ≤ 2.5 cm and SUVmax > 4.35 or tumor size > 2.5 cm and SUVmax ≤ 4.35) and high-risk (tumor size > 2.5 cm and SUVmax > 4.35) groups, the lymph node metastasis rates were 4.3%, 22.7%, and 88.9%, respectively. These results indicate that the combination of SUVmax and tumor size has potential clinical value for predicting occult nodal metastasis in NSCLC patients. PMID:29137276

  9. Occult HCV Infection: The Current State of Knowledge

    PubMed Central

    Rezaee-Zavareh, Mohammad Saeid; Hadi, Reza; Karimi-Sari, Hamidreza; Hossein Khosravi, Mohammad; Ajudani, Reza; Dolatimehr, Fardin; Ramezani-Binabaj, Mahdi; Miri, Seyyed Mohammad; Alavian, Seyed Moayed

    2015-01-01

    Context Occult HCV infection (OCI) is defined as the presence of HCV-RNA in hepatocytes and the absence of HCV in the serum according to usual tests. We aimed to define OCI and provide information about the currently available diagnostic methods. Then we focus on specific groups that are at high risk of OCI and finally investigate immune responses to OCI and the available treatment approaches. Evidence Acquisition PubMed, Scopus and Google Scholar were comprehensively searched with combination of following keywords: “occult”, “hepatitis C virus” and “occult HCV infection”. The definition of OCI, diagnostic methods, specific groups that are at high risk and available treatment approaches were extract from literature. An analysis of available articles on OCI also was done based on Scopus search results. Results OCI has been reported in several high-risk groups, especially in hemodialysis patients and subjects with cryptogenic liver disease. Furthermore, some studies have proposed a specific immune response for OCI in comparison with chronic hepatitis C (CHC). Conclusions With a clinical history of approximately 11 years, occult HCV infection can be considered an occult type of CHC. Evidences suggest that considering OCI in these high-risk groups seems to be necessary. We suggest that alternative diagnostic tests should be applied and that there is a need for the participation of all countries to determine the epidemiology of this type of HCV infection. Additionally, evaluating OCI in blood transfusion centers and in patients who receive large amounts of blood and clotting factors, such as patients with hemophilia, should be performed in future projects. PMID:26734487

  10. Occult Form of Premature Ovarian Insufficiency in Women with Infertility and Oligomenorrhea as Assessed by Poor Ovarian Response Criteria.

    PubMed

    Izhar, Rubina; Husain, Samia; Tahir, Suhaima; Husain, Sonia

    2017-01-01

    The purpose of this study was to evaluate the ability of poor ovarian response criteria to classify women presenting with infertility and oligomenorrhea as having "occult" premature ovarian insufficiency. This was a cross sectional study conducted at Aziz Medical Center, Karachi, Pakistan from 1st August 2015 to 31st July 2016. Women with infertility and oligomenorrhea were included. All eligible women underwent day 2 FSH level and an early follicular phase transvaginal ultrasound to assess the antral follicular count (AFC). All women then underwent the confirmatory test, of Anti-Mullerian Hormone (AMH) level. The main outcome measure was assignment to occult premature ovarian insufficiency (POI) after screening that used the criteria set out in fertility guideline for predicting the likely ovarian response to gonadotrophin stimulation. Another measure was to compare the sensitivity and specificity of the two index criteria, of FSH and AFC, relative to the emerging reference standard, of the AMH criterion. The three criteria together classified 59 (34.91%) women as occult POI in those with oligomenorrhea. The sensitivity, specificity, negative predictive value and positive predictive value of FSH relative to AMH for these women were 77.8%, 95.7%, 90.2% and 89.4%, respectively whereas the same values of AFC relative to AMH were 92.6%, 99.1 %, 96.6% and 98%, respectively. Women with menstrual irregularity and infertility are at a higher risk for satisfying criteria of poor ovarian response irrespective of age. A policy incorporating these surrogate markers can be used to screen these women for occult premature ovarian insufficiency.

  11. Sat-sat Radio Occultation Experiment between Yinghuo-1 and Phobos-Grunt at Mars

    NASA Astrophysics Data System (ADS)

    Zhao, Hua; Sun, Yue-Qiang; Wu, Ji

    Sat-sat Radio Occultation Experiment between Yinghuo-1 and Phobos-Grunt at Mars Hua Zhao1, J. Wu1, Y. Q. Sun1, G. W. Zhu1, Q. F. Du1, X. Hu1, A. Zakharov2 1Center for Space Science and Applied Research (CSSAR), Chinese Academy of Sciences, Beijing, China 2IKI, Russian Academy of Sciences, Moscow, Russia Abstract: A micro-satellite, Yinghuo-1, would be launched with Phobos-Grunt in October, 2009 to investigate the space environment around Mars. A coordinated radio occultation experiment would be carried out between YH-1 and Phobos-Grunt. A radio wave transmitter is mounted on Phobos-Grunt to beam out radio wave at 400/800 MHz in 6W output to YH-1, and a radio receiver is installed on YH-1 to measure the phase shift and xxx during the occultation opportunities. The total electron content (TEC) can be obtained from the occultation experiment, and the Martian electron density profiles would be driven out. After inserting into Mars orbit, YH-1 would be separated from Phobos-Grunt with a relative speed of 2m/s, and the orbits of YH-1 and Phobos-Grunt are placed in the same plan near the Mars equator, and the ROE would have opportunities to measure the Mars ionospheric electron density profiles in the altitude range 50—300 km with solar zenith angle (SZA) smaller than 43o, and larger than 138o. The micro-strip antenna is used for the receiver on YH-1, and the sensitivity of the receiver is about -145dBm.

  12. Vertical fogwater flux measurements above an elevated forest canopy at the Lägeren research site, Switzerland

    NASA Astrophysics Data System (ADS)

    Burkard, Reto; Bützberger, Patrick; Eugster, Werner

    During the winter of 2001/2002 wet and occult deposition measurements were performed at the Lägeren research site ( 690 m a.s.l.) in Switzerland. Two types of fog were observed: radiation fog (RF) and fog associated with atmospheric instabilities (FAI). The deposition measurements were performed above the forest canopy on a 45 m high tower. Occult deposition was measured by means of the eddy covariance method. Due to the large differences of microphysical properties of the two fog types, the liquid water fluxes were much higher (6.9 mg m -2 s-1) during RF than during FAI (0.57 mg m -2 s-1) . Fogwater concentrations were considerably enhanced during RF compared with FAI. The comparison of fog and rain revealed that fogwater nutrient concentrations were 3-66 times larger than concentrations in precipitation. The considerably larger water fluxes and nutrient concentrations of RF resulted in much higher nutrient deposition compared with FAI. In winter when RF was quite frequent, occult deposition was the dominant pathway for nitrate and ammonium deposition. Daily fluxes of total inorganic nitrogen were 1.89 mg m -2 d-1 by occult and 1.01 mg m -2 d-1 by wet deposition. The estimated contribution of occult deposition to total annual nitrogen input was 16.4% or 4.3 kg N ha -1 yr-1, and wet deposition contributed 26.5% ( 6.9 kg N ha -1 yr-1) . As a consequence, critical loads of annual N-input were exceeded, resulting in a significant over-fertilization at the Lägeren site.

  13. Dusty Dwarfs Galaxies Occulting A Bright Background Spiral

    NASA Astrophysics Data System (ADS)

    Holwerda, Benne

    2017-08-01

    The role of dust in shaping the spectral energy distributions of low mass disk galaxies remains poorly understood. Recent results from the Herschel Space Observatory imply that dwarf galaxies contain large amounts of cool (T 20K) dust, coupled with very modest optical extinctions. These seemingly contradictory conclusions may be resolved if dwarfs harbor a variety of dust geometries, e.g., dust at larger galactocentric radii or in quiescent dark clumps. We propose HST observations of six truly occulting dwarf galaxies drawn from the Galaxy Zoo catalog of silhouetted galaxy pairs. Confirmed, true occulting dwarfs are rare as most low-mass disks in overlap are either close satellites or do not have a confirmed redshift. Dwarf occulters are the key to determining the spatial extent of dust, the small scale structure introduced by turbulence, and the prevailing dust attenuation law. The recent spectroscopic confirmation of bona-fide low mass occulting dwarfs offers an opportunity to map dust in these with HST. What is the role of dust in the SED of these dwarf disk galaxies? With shorter feedback scales, how does star-formation affect their morphology and dust composition, as revealed from their attenuation curve? The resolution of HST allows us to map the dust disks down to the fine scale structure of molecular clouds and multi-wavelength imaging maps the attenuation curve and hence dust composition in these disks. We therefore ask for 2 orbits on each of 6 dwarf galaxies in F275W, F475W, F606W, F814W and F125W to map dust from UV to NIR to constrain the attenuation curve.

  14. Boundary Layer Remote Sensing with Combined Active and Passive Techniques: GPS Radio Occultation and High-Resolution Stereo Imaging (WindCam) Small Satellite Concept

    NASA Technical Reports Server (NTRS)

    Mannucci, A.J.; Wu, D.L.; Teixeira, J.; Ao, C.O.; Xie, F.; Diner, D.J.; Wood, R.; Turk, Joe

    2012-01-01

    Objective: significant progress in understanding low-cloud boundary layer processes. This is the Single largest uncertainty in climate projections. Radio occultation has unique features suited to boundary layer remote sensing (1) Cloud penetrating (2) Very high vertical resolution (approximately 50m-100m) (3) Sensitivity to thermodynamic variables

  15. The DSN radio science system

    NASA Technical Reports Server (NTRS)

    Buckles, B. J.

    1981-01-01

    The Radio Science experiments at Voyager 1 Saturn encounter which included two atmospheric occultations, a planetary ring occultation, and ring scattering experiment were supported by Deep Space Stations in Australia (DSS 43) and Spain (DSS 63). The DSN Radio Science System data flow from receipt of the radio signals at the antenna to delivery of the recorded data to the project are described.

  16. 16 febbraio 2004. 121 Hermione occulta la stella TYC 1905-00864-1 in Gemini

    NASA Astrophysics Data System (ADS)

    Corbisiero, Massimo

    2005-04-01

    On 16 February 2004, the asteroid 121 Hermione occulted the star TYC 1905-00864-1 in Gemini: new astrometric observations and duplicity of the asteroid lead the UAI Occultation Section to launch a call for observations throughout Italy. Interesting results have been obtained along with new dimensions of the asteroid derived from positive observations.

  17. Pioneer-Venus radio occultation (ORO) data reduction: Profiles of 13 cm absorptivity

    NASA Technical Reports Server (NTRS)

    Steffes, Paul G.

    1990-01-01

    In order to characterize possible variations in the abundance and distribution of subcloud sulfuric acid vapor, 13 cm radio occultation signals from 23 orbits that occurred in late 1986 and 1987 (Season 10) and 7 orbits that occurred in 1979 (Season 1) were processed. The data were inverted via inverse Abel transform to produce 13 cm absorptivity profiles. Pressure and temperature profiles obtained with the Pioneer-Venus night probe and the northern probe were used along with the absorptivity profiles to infer upper limits for vertical profiles of the abundance of gaseous H2SO4. In addition to inverting the data, error bars were placed on the absorptivity profiles and H2SO4 abundance profiles using the standard propagation of errors. These error bars were developed by considering the effects of statistical errors only. The profiles show a distinct pattern with regard to latitude which is consistent with latitude variations observed in data obtained during the occultation seasons nos. 1 and 2. However, when compared with the earlier data, the recent occultation studies suggest that the amount of sulfuric acid vapor occurring at and below the main cloud layer may have decreased between early 1979 and late 1986.

  18. Study of the Plutino Object (208996) 2003 AZ84 from Stellar Occultations: Size, Shape, and Topographic Features

    NASA Astrophysics Data System (ADS)

    Dias-Oliveira, A.; Sicardy, B.; Ortiz, J. L.; Braga-Ribas, F.; Leiva, R.; Vieira-Martins, R.; Benedetti-Rossi, G.; Camargo, J. I. B.; Assafin, M.; Gomes-Júnior, A. R.; Baug, T.; Chandrasekhar, T.; Desmars, J.; Duffard, R.; Santos-Sanz, P.; Ergang, Z.; Ganesh, S.; Ikari, Y.; Irawati, P.; Jain, J.; Liying, Z.; Richichi, A.; Shengbang, Q.; Behrend, R.; Benkhaldoun, Z.; Brosch, N.; Daassou, A.; Frappa, E.; Gal-Yam, A.; Garcia-Lozano, R.; Gillon, M.; Jehin, E.; Kaspi, S.; Klotz, A.; Lecacheux, J.; Mahasena, P.; Manfroid, J.; Manulis, I.; Maury, A.; Mohan, V.; Morales, N.; Ofek, E.; Rinner, C.; Sharma, A.; Sposetti, S.; Tanga, P.; Thirouin, A.; Vachier, F.; Widemann, T.; Asai, A.; Hayato, Watanabe; Hiroyuki, Watanabe; Owada, M.; Yamamura, H.; Hayamizu, T.; Bradshaw, J.; Kerr, S.; Tomioka, H.; Andersson, S.; Dangl, G.; Haymes, T.; Naves, R.; Wortmann, G.

    2017-07-01

    We present results derived from four stellar occultations by the plutino object (208996) 2003 AZ84, detected on 2011 January 8 (single-chord event), 2012 February 3 (multi-chord), 2013 December 2 (single-chord), and 2014 November 15 (multi-chord). Our observations rule out an oblate spheroid solution for 2003 AZ84's shape. Instead, assuming hydrostatic equilibrium, we find that a Jacobi triaxial solution with semiaxes (470+/- 20)× (383+/- 10)× (245+/- 8) km can better account for all our occultation observations. Combining these dimensions with the rotation period of the body (6.75 hr) and the amplitude of its rotation light curve, we derive a density ρ =0.87+/- 0.01 g cm-3, a geometric albedo {p}V=0.097+/- 0.009. A grazing chord observed during the 2014 occultation reveals a topographic feature along 2003 AZ84's limb, which can be interpreted as an abrupt chasm of width ˜23 km and depth > 8 km, or a smooth depression of width ˜80 km and depth ˜13 km (or an intermediate feature between those two extremes).

  19. Right upper-quadrant pain in a patient with drug abuse, secondary syphilis and occult hepatitis B virus.

    PubMed

    Fielding, Cory M; Angulo, Paul

    2014-01-01

    To describe the etiology of hepatitis and identify occult hepatitis B virus (HBV) infection. A 40-year-old man presented with severe abdominal pain and jaundice, a history of acute HBV infection that had cleared as well as the use of acetaminophen, methamphetamine, buprenorphine and marijuana. He admitted to having had unprotected sex with multiple partners of both genders. A thorough skin examination revealed papulosquamous lesions on his penis, scrotum, upper and lower extremities and feet. Transaminases and bilirubin were elevated. His rapid plasma reagin was reactive, and hepatitis serologies showed occult HBV. Liver biopsy showed severe hepatitis, but the stains for hepatitis B surface antigen and hepatitis B core antigen were negative. The pathological findings were highly indicative of drug-induced hepatitis without evidence of chronic hepatitis, reactivation of HBV or syphilitic hepatitis. With supportive management and abstinence from drugs, his condition improved. This case describes a patient with multiple potential causes for hepatitis and highlights the importance of obtaining a detailed social history. Further, one should consider the presence of occult HBV and recognize the serologic pattern. © 2014 S. Karger AG, Basel.

  20. Radiographic diagnosis of occult distal fibular avulsion fracture in children with acute lateral ankle sprain.

    PubMed

    Kwak, Yoon-Hae; Lim, Jae-Young; Oh, Min-Kyung; Kim, Woo-Jin; Park, Kun-Bo

    2015-06-01

    Skeletally immature children with ankle sprain are presumed to have distal fibula fracture than ligamentous injury. The purpose of this study is to determine the incidence of associated occult avulsion fracture in children with lateral ankle sprain and the efficacy of identifying fractures using anterior talofibular ligament view. Patients who were diagnosed with distal fibular fracture in the initial ankle anteroposterior, lateral, and mortise were excluded and 78 patients (below 16 y of age) who had been initially diagnosed as ankle sprain were included. The initial and 4 weeks' follow-up ankle series and additional anterior talofibular ligament view suggested by Haraguchi were evaluated. Twenty patients were diagnosed with occult distal fibular avulsion fracture. Ten patients were diagnosed in anterior talofibular ligament view and others were diagnosed in the follow-up radiography. Displacement was highest on the anterior talofibular ligament view. This study found 20 (26%) of 78 ankle sprain show occult avulsion fracture in the anterior talofibular ligament view or follow-up radiography. The anterior talofibular ligament view is an appropriate radiologic view for the diagnosis of distal fibular avulsion fracture. Level IV--diagnostic study.

  1. The impact of spherical symmetry assumption on radio occultation data inversion in the ionosphere: An assessment study

    NASA Astrophysics Data System (ADS)

    Shaikh, M. M.; Notarpietro, R.; Nava, B.

    2014-02-01

    'Onion-peeling' is a very common technique used to invert Radio Occultation (RO) data in the ionosphere. Because of the implicit assumption of spherical symmetry for the electron density (N(e)) distribution in the ionosphere, the standard Onion-peeling algorithm could give erroneous concentration values in the retrieved electron density profile. In particular, this happens when strong horizontal ionospheric electron density gradients are present, like for example in the Equatorial Ionization Anomaly (EIA) region during high solar activity periods. In this work, using simulated RO Total Electron Content (TEC) data computed by means of the NeQuick2 ionospheric electron density model and ideal RO geometries, we tried to formulate and evaluate an asymmetry level index for quasi-horizontal TEC observations. The asymmetry index is based on the electron density variation that a signal may experience along its path (satellite to satellite link) in a RO event and is strictly dependent on the occultation geometry (e.g. azimuth of the occultation plane). A very good correlation has been found between the asymmetry index and errors related to the inversion products, in particular those concerning the peak electron density NmF2 estimate and the Vertical TEC (VTEC) evaluation.

  2. Astrometry of the Orcus/Vanth occultation on UT 7 March 2017

    NASA Astrophysics Data System (ADS)

    Bosh, Amanda S.; Zuluaga, Carlos; Levine, Stephen; Sickafoose, Amanda A.; Genade, Anja; Schindler, Karsten; Lister, Tim; Person, Michael J.

    2017-10-01

    On UT 7 March 2017, Orcus was predicted to occult a star with m=14.3. Observations were made at five observatories: the 0.6-m Astronomical Telescope of the University of Stuttgart (ATUS) at Sierra Remote Observatories (SRO), California; Las Cumbres Observatory’s 1-m telescope (ELP) at McDonald Observatory, Fort Davis, Texas; NASA’s 3-m InfraRed Telescope Facility (IRTF) on Mauna Kea, Hawaii; the 4.1-m Southern Astrophysical Research telescope (SOAR) on Cerro Pachón, Chile; and the 0.6-m Southeastern Association for Research in Astronomy telescope (SARA-CT) at Cerro Tololo, Chile. While observations at all sites were successful, only two—ELP and IRTF—observed solid-body occultation signatures. We will discuss the various predictions for this event and the reasons for the differences among them, including an offset of 130 mas for the star position from the position in the Gaia catalog. The sum of the positive and negative detections place constraints on the geometry of the Orcus/Vanth system, and we present our astrometric results for the geometric solution for this occultation. The implications of the light curve analyses are presented by Sickafoose et al., this conference.

  3. Results from the 2014 November 15th Multi-chord Stellar Occultation by the TNO (229762) 2007 UK126

    NASA Astrophysics Data System (ADS)

    Benedetti-Rossi, G.; Sicardy, B.; Buie, M. W.; Ortiz, J. L.; Vieira-Martins, R.; Keller, J. M.; Braga-Ribas, F.; Camargo, J. I. B.; Assafin, M.; Morales, N.; Duffard, R.; Dias-Oliveira, A.; Santos-Sanz, P.; Desmars, J.; Gomes-Júnior, A. R.; Leiva, R.; Bardecker, J.; Bean, J. K., Jr.; Olsen, A. M.; Ruby, D. W.; Sumner, R.; Thirouin, A.; Gómez-Muñoz, M. A.; Gutierrez, L.; Wasserman, L.; Charbonneau, D.; Irwin, J.; Levine, S.; Skiff, B.

    2016-12-01

    We present results derived from the first multi-chord stellar occultation by the trans-Neptunian object (229762) 2007 UK126, observed on 2014 November 15. The event was observed by the Research and Education Collaborative Occultation Network project and International Occultation Timing Association collaborators throughout the United States. Use of two different data analysis methods obtain a satisfactory fit to seven chords, yielding an elliptical fit to the chords with an equatorial radius of R={338}-10+15 km and equivalent radius of {R}{eq}={319}-7+14 km. A circular fit also gives a radius of R={324}-23+30 km. Assuming that the object is a Maclaurin spheroid with indeterminate aspect angle, and using two published absolute magnitudes for the body, we derive possible ranges for geometric albedo between {p}V={0.159}-0.013+0.007 and {p}R={0.189}-0.015+0.009, and for the body oblateness between ɛ ={0.105}-0.040+0.050 and ɛ ={0.118}-0.048+0.055. For a nominal rotational period of 11.05 hr, an upper limit for density of ρ = 1740 kg m-3 is estimated for the body.

  4. Vertical Profiles of Phosphine and Ammonia on Saturn Derived from the First Cassini RSS Occultation Observation Using Forward Modeling

    NASA Astrophysics Data System (ADS)

    Mohammed, P. N.; Steffes, P. G.; Kliore, A. J.; Anabtawi, A.; Asmar, S. W.; Barbinis, E.; Goltz, G.; Johnston, D.; Marouf, E. A.

    2005-08-01

    The results from the first Cassini Radio Science Subsystem(RSS) occultation, which occurred at the Rev 7 periapse, are being used to derive profiles of the atmospheric constituents encountered by the three frequency (S-, X-, and Ka-band) radio link. A computer model has been developed to simulate ray paths and the ray path parameters in the atmosphere of Saturn encountered during occultation (see Mohammed and Steffes, Bull. Amer. Astron. Soc., 36, no. 4, 1107, 2004). This forward model, which can be used on any oblate planet, will be used to determine the refractive defocusing and derive the profiles of phosphine and ammonia using data observed at Ka-band (32 GHz or 9.3 mm), X-band (8.4 GHz or 3.6 cm) and S-band (2.3 GHz or 13 cm). The results of laboratory measurements of the 9 mm opacity of phosphine and ammonia (Mohammed and Steffes, ICARUS 166, 425-435, 2003) and the centimeter wavelength opacity of these constituents measured under simulated conditions for Saturn (see, e.g., Hoffman et. al. ICARUS 152, 172-184, 2001) were incorporated into the forward radio occultation model used in these derivations.

  5. Estimation of ionospheric sporadic E intensities from GPS radio occultation measurements

    NASA Astrophysics Data System (ADS)

    Arras, C.; Wickert, J.

    2018-06-01

    The radio occultation experiment aboard the FORMOSAT-3/COSMIC satellites enables the observation of phenomena in Earth's ionosphere on a global scale. Numerous radio occultation profiles are used to analyse the occurrence of sporadic E layers as well as its properties. We will present a new method to approach additionally to the presence of sporadic E also its intensity which is closely related to the blanketing frequency (fbEs) provided by ionosondes. We observed that the sporadic E occurrence and its intensity show a highly developed annual cycle with high occurrence rates and intensities in the actual summer hemisphere. The global latitude/longitude distribution of both parameters is strongly related to Earth's magnetic field which is reflected by the missing of sporadic E observations along the magnetic equator.

  6. The JWST/NIRCam Coronagraph: Mask Design and Fabrication

    NASA Technical Reports Server (NTRS)

    Krista, John E.; Balasubramanian, Kunjithapatha; Beichman, Charles A.; Echternach, Pierre M.; Green, Joseph J.; Liewer, Kurt M.; Muller, Richard E.; Serabyn, Eugene; Shaklan, Stuart B.; Trauger, John T.; hide

    2009-01-01

    The NIRCam instrument on the James Webb Space Telescope will provide coronagraphic imaging from lambda =1-5 microns of high contrast sources such as extrasolar planets and circumstellar disks. A Lyot coronagraph with a variety of circular and wedge-shaped occulting masks and matching Lyot pupil stops will be implemented. The occulters approximate grayscale transmission profiles using halftone binary patterns comprising wavelength-sized metal dots on anti-reflection coated sapphire substrates. The mask patterns are being created in the Micro Devices Laboratory at the Jet Propulsion Laboratory using electron beam lithography. Samples of these occulters have been successfully evaluated in a coronagraphic testbed. In a separate process, the complex apertures that form the Lyot stops will be deposited onto optical wedges. The NIRCam coronagraph flight components are expected to be completed this year.

  7. Chromatic refraction with global ozone monitoring by occultation of stars. I. Description and scintillation correction.

    PubMed

    Dalaudier, F; Kan, V; Gurvich, A S

    2001-02-20

    We describe refractive and chromatic effects, both regular and random, that occur during star occultations by the Earth's atmosphere. The scintillation that results from random density fluctuations, as well as the consequences of regular chromatic refraction, is qualitatively described. The resultant chromatic scintillation will produce random features on the Global Ozone Monitoring by Occultation of Stars (GOMOS) spectrometer, with an amplitude comparable with that of some of the real absorbing features that result from atmospheric constituents. A correction method that is based on the use of fast photometer signals is described, and its efficiency is discussed. We give a qualitative (although accurate) description of the phenomena, including numerical values when needed. Geometrical optics and the phase-screen approximation are used to keep the description simple.

  8. Monitoring the Low-Energy Gamma-Ray Sky Using Earth Occultation with GLAST GBM

    NASA Technical Reports Server (NTRS)

    Case, G.; Wilson-Hodge, C.; Cherry, M.; Kippen, M.; Ling, J.; Radocinski, R.; Wheaton, W.

    2007-01-01

    Long term all-sky monitoring of the 20 keV - 2 MeV gamma-ray sky using the Earth occultation technique was demonstrated by the BATSE instrument on the Compton Gamma Ray Observatory. The principles and techniques used for the development of an end-to-end earth occultation data analysis system for BATSE can be extended to the GLAST Gamma-ray Burst Monitor (GBM), resulting in multiband light curves and time-resolved spectra in the energy range 8 keV to above 1 MeV for known gamma-ray sources and transient outbursts, as well as the discovery of new sources of gamma-ray emission. In this paper we describe the application of the technique to the GBM. We also present the expected sensitivity for the GBM.

  9. Radial widths, optical depths, and eccentricities of the Uranian rings

    NASA Technical Reports Server (NTRS)

    Nicholson, P. D.; Matthews, K.; Goldreich, P.

    1982-01-01

    Observations of the stellar occultation by the Uranian rings of 15/16 August 1980 are used to estimate radial widths and normal optical depths for segments of rings 6, 5, 4, alpha, beta, eta, gamma, and delta. Synthetic occultation profiles are generated to match the observed light curves. A review of published data confirms the existence of width-radius relations for rings alpha and beta, and indicates that the optical depths of these two rings vary inversely with their radial widths. Masses are obtained for rings alpha and beta, on the assumption that differential precession is prevented by their self-gravity. A quantitative comparison of seven epsilon-ring occultation profiles obtained over a period of 3.4 yr reveals a consistent structure, which may reflect the presence of unresolved gaps and subrings.

  10. Profile inversion in presence of ray bending

    NASA Technical Reports Server (NTRS)

    Wallio, H. A.; Grossi, M. D.

    1972-01-01

    Inversion of radio occultation data for planetary atmospheres and ionospheres has been performed using the seismological Herglotz-Wiechert method, as adapted by Phinney and Anderson to the radio-occultation case. Profile reconstruction performed in computer simulated experiments with this approach have been compared with the ones obtained with the straight-ray Abel transform. For a thin atmosphere and ionosphere, like the ones encountered on Mars, microwave occultation data can be inverted accurately with both methods. For a dense ionosphere like the sun's corona, ray bending of microwaves is severe, and recovered refractivity by the Herglotz-Wiechert method provides significant improvement over the straight-ray Abel transform: the error reduces from more than 60% to less than 20% at a height of 60,000 km above the base of the corona.

  11. The Active Latitudes of HAT-P-11

    NASA Astrophysics Data System (ADS)

    Morris, Brett; Hebb, Leslie; Davenport, James R. A.; Hawley, Suzanne L.

    2017-01-01

    Transiting planets map the brightness of their host stars, as the flux lost during exoplanet transits is proportional to the integrated flux occulted by the planet. We analyze four years of Kepler short-cadence photometry of HAT-P-11 - an active K4 dwarf with a 29 day rotation period, orbited by a hot-Neptune. Due to its highly-misaligned orbit, the planet occults most stellar latitudes during each transit, and the latitude distribution of spots is encoded in the transit light curves. We model each spot occultation in transit to create a spot map of HAT-P-11, which reveals two active latitudes near ±17 degrees. We investigate whether the spot distribution changes in time, and we compare the spot latitude distributions of HAT-P-11 and the Sun throughout the solar activity cycle.

  12. The Atmospheric Structure of Triton and Pluto

    NASA Technical Reports Server (NTRS)

    Elliot, James L.

    1998-01-01

    The goal of this research was to better determine the atmospheric structures of Triton and Pluto through further analysis of three occultation data sets obtained with the Kuiper Airborne Observatory (KAO.) As the research progressed, we concentrated our efforts on the Triton data, as this appeared to be the most fruitful. Three papers have been prepared as a result of this research. The first paper presents new results about Triton's atmospheric structure from the analysis of all ground-based stellar occultation data recorded to date, including one single-chord occultation recorded on 1993 July 10 and nine occultation lightcurves from the double-star event on 1995 August 14. These stellar occultation observations made both in the visible and in the infrared have good spatial coverage of Triton, including the first Triton central-flash observations, and are the first data to probe the altitude level 20-100 km on Triton. The small-planet lightcurve model of J. L. Elliot and L. A. Young was generalized to include stellar flux refracted by the far limb, and then fitted to the data. Values of the pressure, derived from separate immersion and emersion chords, show no significant trends with latitude, indicating that Triton's atmosphere is spherically symmetric at approximately 50 km altitude to within the error of the measurements; however, asymmetry observed in the central flash indicates the atmosphere is not homogenous at the lowest levels probed (approximately 20 km altitude). From the average of the 1995 occultation data, the equivalent isothermal temperature of the atmosphere is 47 plus or minus 1 K and the atmospheric pressure at 1400 km radius (approximately 50 km altitude) is 1.4 plus or minus 0.1 microbar. Both of these are not consistent with a model based on Voyager UVS and RSS observations in 1989. The atmospheric temperature from the occultation is 5 K colder than that predicted by the model and the observed pressure is a factor of 1.8 greater than the model. In our opinion, the disagreement in temperature and pressure is probably due to modeling problems at the microbar level, since measurements at this level have not previously been made. Alternatively, the difference could be due to seasonal change in Triton's atmospheric structure. The second paper reports observations of a recent stellar occultation by Triton which, when combined with earlier results, show that Triton has undergone a period of global warming since 1989. The most conservative estimates of the rate of temperature and surface-pressure increase during this period imply that the atmosphere is doubling in bulk every 10 years -- significantly faster than predicted by published frost model for Triton. Our results suggests that permanent polar caps on Triton play a dominant role in regulating seasonal atmospheric changes. Similar processes should also be active on Pluto. A third paper 'Global Warming on Triton' will appear in a the January 1999 issue of Sky and Telescope.

  13. ASPIICS: a giant, white light and emission line coronagraph for the ESA proba-3 formation flight mission

    NASA Astrophysics Data System (ADS)

    Lamy, P. L.; Vivès, S.; Curdt, W.; Damé, L.; Davila, J.; Defise, J.-M.; Fineschi, S.; Heinzel, P.; Howard, Russel; Kuzin, S.; Schmutz, W.; Tsinganos, K.; Zhukov, A.

    2017-11-01

    Classical externally-occulted coronagraphs are presently limited in their performances by the distance between the external occulter and the front objective. The diffraction fringe from the occulter and the vignetted pupil which degrades the spatial resolution prevent useful observations of the white light corona inside typically 2-2.5 solar radii (Rsun). Formation flying offers and elegant solution to these limitations and allows conceiving giant, externally-occulted coronagraphs using a two-component space system with the external occulter on one spacecraft and the optical instrument on the other spacecraft at a distance of hundred meters [1, 2]. Such an instrument ASPIICS (Association de Satellites Pour l'Imagerie et l'Interférométrie de la Couronne Solaire) has been selected by the European Space Agency (ESA) to fly on its PROBA-3 mission of formation flying demonstration which is presently in phase B (Fig. 1). The classical design of an externally-occulted coronagraph is adapted to the formation flying configuration allowing the detection of the very inner corona as close as 0.04 solar radii from the solar limb. By tuning the position of the occulter spacecraft, it may even be possible to reach the chromosphere and the upper part of the spicules [3]. ASPIICS will perform (i) high spatial resolution imaging of the continuum K+F corona in photometric and polarimetric modes, (ii) high spatial resolution imaging of the E-corona in two coronal emission lines (CEL): Fe XIV and He I D3, and (iii) two-dimensional spectrophotometry of the Fe XIV emission line. ASPIICS will address the question of the coronal heating and the role of waves by characterizing propagating fluctuations (waves and turbulence) in the solar wind acceleration region and by looking for oscillations in the intensity and Doppler shift of spectral lines. The combined imaging and spectral diagnostics capabilities available with ASPIICS will allow mapping the velocity field of the corona both in the sky plane (directly on the images) and along the line-of-sight by measuring the Doppler shifts of emission lines in an effort to determine how the different components of the solar wind, slow and fast are accelerated. With a possible launch in 2014, ASPIICS will observe the corona during the maximum of solar activity, insuring the detection of many Coronal Mass Ejections (CMEs). By rapidly alternating high-resolution imaging and spectroscopy, CMEs will be thoroughly characterized.

  14. Abundances of O3 and O2 in the Martian Atmosphere Retrieved from MAVEN/IUVS Stellar Occultations

    NASA Astrophysics Data System (ADS)

    Gröller, H.; Lefèvre, F.; Gonzalez-Galindo, F.; Yelle, R. V.; Koskinen, T.; Montmessin, F.; Schneider, N.; Deighan, J.; Jain, S.

    2017-12-01

    We present O3 and O2 abundances retrieved from stellar occultations taken with the Imaging UltraViolet Spectrometer (IUVS) on MAVEN. The IUVS instrument has two separate spectral channels, the FUV and the MUV channel from 110 to 190 nm and from 180 to 340 nm, respectively. The O3 absorption feature is present in the MUV channel, whereas the O2 absorption features are in the FUV channel. So far, 15 stellar occultation campaigns have been executed on average every two to three months; covering more than one Martian year. During these campaigns, more than 900 stellar occultations were recorded. From those 900 stellar occultations, around 50 % can be used for O2 detection and around 25 % for O3. We detect O3 in almost 40 % of the occultations that can be used for O3 retrievals. The obtained O3 profiles are between 20 and 60 km and show a maximum number density around 30 to 40 km. The peak O3 number density varies almost one order of magnitude; between a few times 108 cm-3 and 2 x 109 cm-3. Our measurements show that the most O3 is present during the first half of the Martian year (up to a solar longitude of around 140°, end of northern summer) with a maximum around 60° solar longitude (close to aphelion). In most of the cases, the retrieved O3 profiles are in agreement with the LMD-MGCM predicted values. However, in some cases a difference in altitude and pressure space can be seen. Furthermore, during the northern early spring season, higher number densities at altitudes above 40 km can be seen in the data. The retrieved density profiles of O2 cover an altitude range from around 90 km up to 150 km. The corresponding O2 mixing ratios range from 1 to 9 x 10-3, also in agreement with previous observations. Even though the O2 mixing ratio shows high variability, the mean value seems to be constant with solar longitude. The obtained O2 profiles agree with previous measurements obtained by the Mars Express SPICAM instrument and by the Viking mass spectrometer. Furthermore, the retrieved O2mixing ratios are in agreement with the LMD-MGCM ratios for solar longitudes greater than around 65° (close to aphelion). However, the O2 mixing ratios predicted with the LMD-MGCM are up to a factor of 10 higher than the mixing ratios derived from stellar occultations during the northern spring season.

  15. Results for Titan's atmosphere from its occultation of 28 Sagittarii

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.; Hunten, D. M.; Reitsema, H. J.; Brosch, N.; Nevo, Y.

    1990-01-01

    The occultation of the bright K giant star 28 Sgr by Titan was observed from three stations in the Mediterranean area, and the resulting data set is examined here. Average mesospheric temperatures of about 180 K are derived, with evidence for lateral and vertical atmospheric inhomogeneities on scales ranging from about 10-1000 km. The results are consistent with published models of Titan's atmosphere.

  16. 1981N1 - A Neptune arc?

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.

    1986-01-01

    An object in the vicinity of Neptune detected in 1981 by simultaneous stellar occultation measurements at observatories near Tucson, Arizona, was interpreted as a new Neptune satellite. A reinterpretation suggests that it may have instead been a Neptune arc similar to one observed in 1984. The 1981 object, however, did not occult the star during simultaneous observations at Flagstaff, Arizona. This result constrains possible arc geometries.

  17. Aplastic crisis in occult hereditary spherocytosis caused by human parvovirus (HPV B19).

    PubMed

    Rappaport, E S; Quick, G; Ransom, D; Helbert, B; Frankel, L S

    1989-02-01

    We have reported a case of aplastic crisis occurring in an 11-year-old black boy with occult hereditary spherocytosis. An etiologic diagnosis of human parvovirus (HPV) B19 infection was confirmed serologically. The Coulter Model S + IV proved useful for both diagnosis and treatment monitoring through serial histograms. The relationship of HPV infection and aplastic crisis is discussed.

  18. Design and Verification of External Occulters for Direct Imaging of Extrasolar Planets

    NASA Technical Reports Server (NTRS)

    Cady, Eric

    2011-01-01

    An occulter is an optical element which is placed in front of the telescope to block most of the light from a star before it reaches the optics inside, without blocking the planet.In our case, we use two spacecraft ying in formation: First has its edge shaped to cancel the starlight Second is the telescope which images the star and planet

  19. Occult abnormal pregnancies after first post-embryo transfer serum beta-human chorionic gonadotropin levels of 1.0-5.0 mIU/mL.

    PubMed

    Maslow, Bat-Sheva L; Bartolucci, Alison; Sueldo, Carolina; Engmann, Lawrence; Benadiva, Claudio; Nulsen, John C

    2016-04-01

    To assess the occult pregnancy rate after "negative" first post-embryo transfer (ET) serum β-hCG results. Two-part retrospective cohort study and nested case series. University-based fertility center. A total of 1,571 negative first post-ET serum β-hCG results were included in the study; 1,326 results (primary cohort, June 2009-December 2013) were initially reported as <5 mIU/mL and 245 results (secondary cohort, January 2014-March 2015) were reported as discrete values from 1.0 to 5.0 mIU/mL. None. Rates of occult pregnancy, ectopic pregnancy, and complications after negative first post-ET serum β-hCG results. A total of 88.8% (1,178/1,326) of the negative first post-ET results reported as <5 were actually <1.0 mIU/mL. Occult pregnancy was incidentally identified in 1.2% (12/1,041) of subjects with follow-up. Six had ectopic pregnancies, and seven experienced serious complications; 11 (91.7%) of the 12 occult pregnancies had a first post-ET serum β-hCG level of 1.0-5.0 mIU/mL and 1 (8.3%) <1.0 mIU/mL. All pregnancies with serious complications had initial β-hCG levels of 1.0-5.0 mIU/mL. Of the 245 results reported as discreet values, occult pregnancies were diagnosed in 5.5% (9/163) of subjects with follow-up. One had an ectopic pregnancy, which was treated with methotrexate. There were no serious complications in the secondary cohort. The majority of negative first post-ET serum β-hCG levels are <1.0 mIU/mL. Results from 1.0 to 5.0 mIU/mL may fail to exclude abnormal pregnancy and are associated with poor outcomes compared with β-hCG levels <1.0 mIU/mL. Serial serum β-hCG may be warranted in this population. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  20. Cost-effectiveness analysis of colorectal cancer screening methods in Iran.

    PubMed

    Allameh, Zahra; Davari, Majid; Emami, Mohammad Hasan

    2011-03-01

    Screening can prevent colorectal cancer from becoming advanced by early detection of precancerous lesions. Cost-effectiveness analysis of colorectal cancer screening methods is highly necessary due to increased prevalence, decreased age at onset and the limited budget in Iran. Methods of screening currently available in Iran were selected. A systematic search revealed the sensitivity and specificity of each method. For this study, a model for a 20 year screening period of a population of 100,000 apparently healthy persons of ages 45-65 years in Isfahan Province was used. The cost-effectiveness of each method and the ratio of cost-effectiveness were calculated based on this model. The most and the least effective methods were CT colonography and fecal occult blood test, respectively. The highest and lowest expenditures in the governmental sector were related to fecal occult blood test and flexible sigmoidoscopy and in the private sector, to CT colonography and fecal occult blood test, respectively. The cost per cancer detected in 20 years of screening in the governmental sector was 0.28, 0.22 and 0.42 billion Rials, respectively for screening by colonoscopy, flexible sigmoidoscopy and fecal occult blood test. In the private sector, these were 1.54 (colonoscopy), 1.68 (flexible sigmoidoscopy), and 1.60 (fecal occult blood test) billion and 2.58 billion Rials for CT colonography, respectively. Although CT colonography is the most effective method, it needs a budget of 2.58 billion Rials for each screened patient. If costs in the governmental sector are considered, flexible sigmoidoscopy would be the most cost-effective method for screening the 45 - 65-year-old population in Iran.

  1. Searching for dust orbiting around activated asteroid 596 Scheila by means of stellar occultations

    NASA Astrophysics Data System (ADS)

    Santos-Sanz, P.; Ortiz, J. L.; Duffard, R.; Morales, N.; Fernández-Valenzuela, E.; Moreno, F.; Licandro, J.; Rizos, J. L.; Maestre, J. L.; Organero, F.; Fonseca, F.; Ana, L.; Pastor, S.; de los Reyes, J. A.

    2017-03-01

    596 Scheila is a main belt asteroid classified from 2010, when it presented cometary appearance, like a Main Belt Comet (MBC). We only known around a dozen of MBCs till to date. The MBCs present asteroid-like orbits -between Mars and Jupiter- but they have cometary appearances and/or behaviours. It is believed that the activity of Scheila was triggered by the impact of a small asteroid (D 35 m) with a velocity 5 km/s. In order to study if the dust around Scheila generated by this collision could have evolved to a thin ring orbiting the body we have predicted stellar occultations by Scheila favourable for Spain during 2015-2016. We found 3 possible favourable events for the dates: 16 December 2015, 6 January 2016 and 21 January 2016. The first event was not observed due to bad weather conditions, the second one was negative, finally, the third event was positive and was observed from two Spanish sites separated 260 km: the ‘Observatorio de Albox’ in Alicante and the ‘Observatorio de La Hita’ in Toledo. From the analysis of this positive multi-chord stellar occultation of a 14.8 magnitude star we have obtained the equivalent diameter in projected area on the sky plane of Scheila at the moment of the occultation (D = 115.1 ± 6.4 km) and its surface geometric albedo (pV = 3.67 ± 0.41 %). Due to the small-sized telescopes involved in this occultation our limit of detection for a dust ring around Scheila at 3σ is of 15 km, with a maximum optical deep τ_{max} = 0.11. The research leading to these results has received funding from the European Union’s Horizon 2020 Research and Innovation Programme, under Grant Agreement no 687378.

  2. The New Horizons Radio Science Experiment: Expected Performance in Measurements of Pluto's Atmospheric Structure, Surface Pressure, and Surface Temperature

    NASA Astrophysics Data System (ADS)

    Hinson, D. P.; Linscott, I.; Woods, W. W.; Tyler, G. L.; Bird, M. K.; Paetzold, M.; Strobel, D. F.

    2014-12-01

    The New Horizons (NH) payload includes a Radio Science Experiment (REX) for investigating key characteristics of Pluto and Charon during the upcoming flyby in July 2015. REX flight equipment augments the NH radio transceiver used for spacecraft communications and tracking. The REX hardware implementation requires 1.6 W and 160 g. This presentation will focus on the final design and the predicted performance of two high-priority observations. First, REX will receive signals from a pair of 70-m antennas on Earth - each transmitting 20 kW at 4.2-cm wavelength - during a diametric radio occultation by Pluto. The data recorded by REX will reveal the surface pressure, the temperature structure of the lower atmosphere, and the surface radius. Second, REX will measure the thermal emission from Pluto at 4.2-cm wavelength during two linear scans across the disk at close range when both the dayside and the nightside are visible, allowing the surface temperature and its spatial variations to be determined. Both scans extend from limb to limb with a resolution of about 10 pixels; one bisects Pluto whereas the second crosses the winter pole. We will illustrate the capabilities of REX by reviewing the method of analysis and the precision achieved in a lunar occultation observed by New Horizons in May 2011. Re-analysis of radio occultation measurements by Voyager 2 at Triton is also under way. More generally, REX objectives include a radio occultation search for Pluto's ionosphere; examination of Charon through both radio occultation and radiometry; a search for a radar echo from Pluto's surface; and improved knowledge of the Pluto system mass and the Pluto-Charon mass ratio from a combination of two-way and one-way Doppler frequency measurements.

  3. Occult gastrointestinal bleeding is a common finding in dogs with chronic kidney disease.

    PubMed

    Crivellenti, Leandro Z; Borin-Crivellenti, Sofia; Fertal, Kristi L; Contin, Catarina M; Miranda, Caroline M J; Santana, Aureo E

    2017-03-01

    The risk of occult gastrointestinal bleeding (OGIB) is known to be increased among human dialysis patients suffering from end-stage renal disease. However, there are no studies to date that investigate the incidence of OGIB in either dogs or people with chronic kidney disease (CKD), irrespective of dialysis. The purpose of the study was to determine whether the incidence of OGIB is greater in dogs with CKD as compared to a control population, and if this pathology is associated with changes in serum variables related to iron metabolism. Fecal occult bleeding was evaluated in 10 healthy dogs and 30 CKD dogs. Test results were compared to indicators of blood loss and/or iron metabolism. Dogs with CKD had a significantly higher incidence of OGIB than the control group (P < .0001). While 80% of dogs with stage 2 CKD did not exhibit anemia, 90% tested positive for OGIB. Similarly, subjects with stage 4 CKD had more significant blood loss than either stage 2 (P = .0071) or stage 3 CKD (P = .0385). Serum hemoglobin, transferrin, and iron concentrations in the CKD group were statistically lower than in the control group (P < .0001) and correlated with fecal occult bleeding (r = -.61; r = -.40; r = -.44, respectively), as well as serum creatinine concentrations (P < .0001, r = .64). This preliminary study suggests that OGIB is a common clinical finding among dogs with CKD, even in the early stages of the disease process. Therefore, fecal occult blood tests may be useful as an indication for gastroprotective agents in the treatment plan. © 2017 American Society for Veterinary Clinical Pathology.

  4. Asymptomatic Hepadnaviral Persistence and Its Consequences in the Woodchuck Model of Occult Hepatitis B Virus Infection

    PubMed Central

    Mulrooney-Cousins, Patricia M.; Michalak, Tomasz I.

    2015-01-01

    Woodchuck hepatitis virus (WHV) is molecularly and pathogenically closely related to hepatitis B virus (HBV). Both viruses display tropism towards hepatocytes and cells of the immune system and cause similar liver pathology, where acute hepatitis can progress to chronic hepatitis and to hepatocellular carcinoma (HCC). Two forms of occult hepadnaviral persistence were identified in the woodchuck-WHV model: secondary occult infection (SOI) and primary occult infection (POI). SOI occurs after resolution of a serologically apparent infection with hepatitis or after subclinical serologically evident virus exposure. POI is caused by small amounts of virus and progresses without serological infection markers, but the virus genome and its replication are detectable in the immune system and with time in the liver. SOI can be accompanied by minimal hepatitis, while the hallmark of POI is normal liver morphology. Nonetheless, HCC develops in about 20% of animals with SOI or POI within 3 to 5 years. The virus persists throughout the lifespan in both SOI and POI at serum levels rarely greater than 100 copies/mL, causes hepatitis and HCC when concentrated and administered to virus-naïve woodchucks. SOI is accompanied by virus-specific T and B cell immune responses, while only virus-specific T cells are detected in POI. SOI coincides with protection against reinfection, while POI does not and hepatitis develops after challenge with liver pathogenic doses >1000 virions. Both SOI and POI are associated with virus DNA integration into the liver and the immune system genomes. Overall, SOI and POI are two distinct forms of silent hepadnaviral persistence that share common characteristics. Here, we review findings from the woodchuck model and discuss the relevant observations made in human occult HBV infection (OBI). PMID:26623268

  5. Asymptomatic Hepadnaviral Persistence and Its Consequences in the Woodchuck Model of Occult Hepatitis B Virus Infection.

    PubMed

    Mulrooney-Cousins, Patricia M; Michalak, Tomasz I

    2015-09-28

    Woodchuck hepatitis virus (WHV) is molecularly and pathogenically closely related to hepatitis B virus (HBV). Both viruses display tropism towards hepatocytes and cells of the immune system and cause similar liver pathology, where acute hepatitis can progress to chronic hepatitis and to hepatocellular carcinoma (HCC). Two forms of occult hepadnaviral persistence were identified in the woodchuck-WHV model: secondary occult infection (SOI) and primary occult infection (POI). SOI occurs after resolution of a serologically apparent infection with hepatitis or after subclinical serologically evident virus exposure. POI is caused by small amounts of virus and progresses without serological infection markers, but the virus genome and its replication are detectable in the immune system and with time in the liver. SOI can be accompanied by minimal hepatitis, while the hallmark of POI is normal liver morphology. Nonetheless, HCC develops in about 20% of animals with SOI or POI within 3 to 5 years. The virus persists throughout the lifespan in both SOI and POI at serum levels rarely greater than 100 copies/mL, causes hepatitis and HCC when concentrated and administered to virus-naïve woodchucks. SOI is accompanied by virus-specific T and B cell immune responses, while only virus-specific T cells are detected in POI. SOI coincides with protection against reinfection, while POI does not and hepatitis develops after challenge with liver pathogenic doses >1000 virions. Both SOI and POI are associated with virus DNA integration into the liver and the immune system genomes. Overall, SOI and POI are two distinct forms of silent hepadnaviral persistence that share common characteristics. Here, we review findings from the woodchuck model and discuss the relevant observations made in human occult HBV infection (OBI).

  6. Analysis of brain and spinal cord lesions to occult brain damage in seropositive and seronegative neuromyelitis optica.

    PubMed

    Sun, Jie; Sun, Xianting; Zhang, Ningnannan; Wang, Qiuhui; Cai, Huanhuan; Qi, Yuan; Li, Ting; Qin, Wen; Yu, Chunshui

    2017-09-01

    According to aquaporin-4 antibody (AQP4-Ab), neuromyelitis optica (NMO) can be divided into seropositive and seronegative subgroups. The purpose of this study was to a) compare the distribution of spinal cord and brain magnetic resonance imaging (MRI) lesions between seropositive and seronegative NMO patients; b) explore occult brain damage in seropositive and seronegative NMO patients; and c) explore the contribution of visible lesions to occult grey and white matter damage in seropositive and seronegative NMO patients. Twenty-two AQP4-Ab seropositive and 14 seronegative NMO patients and 30 healthy controls were included in the study. Two neuroradiologists independently measured the brain lesion volume (BLV) and the length of spinal cord lesion (LSCL) and recorded the region of brain lesions. The normal-appearing grey matter volume (NAGM-GMV) and white matter fractional anisotropy (NAWM-FA) were calculated for each subject to evaluate occult brain damage. The seropositive patients displayed more extensive damage in the spinal cord than the seronegative patients, and the seronegative group had a higher proportion of patients with brainstem lesions (28.57%) than the seropositive group (4.55%, P=0.064). Both NMO subgroups exhibited reduced NAGM-GMV and NAWM-FA compared with the healthy controls. NAGM-GMV was negatively correlated with LSCL in the seropositive group (r s =-0.444, P=0.044) and with BLV in the seronegative group (r s =-0.768, P=0.002). NAWM-FA was also negatively correlated with BLV in the seropositive group (r s =-0.682, P<0.001). Our findings suggest that the occult brain damage in these two NMO subgroups may be due to different mechanisms, which need to be further clarified. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. The incidence of occult malignancy following uterine morcellation: A ten-year single institution experience retrospective cohort study.

    PubMed

    Mori, Kristina M; Abaid, Lisa N; Mendivil, Alberto A; Brown, John V; Beck, Tiffany L; Micha, John P; Epstein, Howard D; Goldstein, Bram H

    2018-05-01

    When the Food and Drug Administration (FDA) initially reported on the parlous incidence (0.28%) of occult malignancy identified following uterine power morcellation, investigations thereafter documented their particular experience with this surgical procedure. Nevertheless, the precise risk of identifying a sarcoma following uterine morcellation remains indeterminate, primarily due to varying study patient risk factors, diagnostic criteria and operative approach. We retrospectively evaluated subjects who underwent an endoscopic hysterectomy and uterine power morcellation for the treatment of a presumptive, benign indication from January 2006 until December 2015. The primary outcome was the incidence of an occult malignancy. Secondarily, we were interested in characterizing the patients' specific clinical (age, menopausal status, body mass index (BMI)) risk factors within the context of a confirmed malignant or pre-malignant pathology. We identified 281 patients who underwent endoscopic surgery that incorporated uterine morcellation. During the study period, one subject was ultimately diagnosed with a uterine leiomyosarcoma; the overall incidence of occult malignancy was 0.36%. There were also 3 cases of uterine premalignant disease on final pathology (2 patients had complex hyperplasia with or without atypia and 1 subject was diagnosed with a smooth muscle tumor of uncertain malignant potential (an incidence of 1.1%)). We were unable to establish any relationship between patient age, uterine weight, menopausal status or BMI and the incidence of a malignant or pre-malignant pathology (P > 0.05). The rate of occult malignancy in the present investigation was similar to previously documented studies and that which has been reported by the FDA. Additional study of methods in which to enhance preoperative work-up and mitigate the surgical risk for tumor cell dissemination is warranted. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  8. The Structure of Titan's Atmosphere from Cassini Radio Occultations

    NASA Technical Reports Server (NTRS)

    Schinder, Paul J.; Flasar, F. Michael; Marouf, Essam A.; French, Richard G.; McGhee, Colleen A.; Kliore, Arvydas J.; Rappaport, Nicole J.; Barbinis, Elias; Fleischman, Don; Anabtawi, Aseel

    2011-01-01

    We present results from the two radio occultations of the Cassini spacecraft by Titan in 2006, which probed mid-southern latitudes. Three of the ingress and egress soundings occurred within a narrow latitude range, 31.34 deg S near the surface, and the fourth at 52.8 deg S. Temperature - altitude profiles for all four occultation soundings are presented, and compared with the results of the Voyager 1 radio occultation (Lindal et al., 1983), the HASI instrument on the Huygens descent probe (Fulchignoni et al., 2005), and Cassini CIRS results (Flasar et al., 2005; Achterberg et al., 2008b). Sources of error in the retrieved temperature - altitude profiles are also discussed, and a major contribution is from spacecraft velocity errors in the reconstructed ephemeris. These can be reduced by using CIRS data at 300 km to make along-track adjustments of the spacecraft timing. The occultation soundings indicate that the temperatures just above the surface at 31-34 deg S are about 93 K, while that at 53 deg S is about 1 K colder. At the tropopause, the temperatures at the lower latitudes are all about 70 K, while the 53 deg S profile is again 1 K colder. The temperature lapse rate in the lowest 2 km for the two ingress (dawn) profiles at 31 and 33 deg S lie along a dry adiabat except within approximately 200m of the surface, where a small stable inversion occurs. This could be explained by turbulent mixing with low viscosity near the surface. The egress profile near 34 deg S shows a more complex structure in the lowest 2 km, while the egress profile at 53 deg S is more stable.

  9. Occultation Predictions Using CCD Strip-Scanning Astrometry

    NASA Technical Reports Server (NTRS)

    Dunham, Edward W.; Ford, C. H.; Stone, R. P. S.; McDonald, S. W.; Olkin, C. B.; Elliot, J. L.; Witteborn, Fred C. (Technical Monitor)

    1994-01-01

    We are developing the method of CCD strip-scanning astrometry for the purpose of deriving reliable advance predictions for occultations involving small objects in the outer solar system. We are using a camera system based on a Ford/Loral 2Kx2K CCD with the Crossley telescope at Lick Observatory for this work. The columns of die CCD are aligned East-West, the telescope drive is stopped, and the CCD is clocked at the same rate that the stars drift across it. In this way we obtain arbitrary length strip images 20 arcmin wide with 0.58" pixels. Since planets move mainly in RA, it is possible to obtain images of the planet and star to be occulted on the same strip well before the occultation occurs. The strip-to-strip precision (i.e. reproducibility) of positions is limited by atmospheric image motion to about 0.1" rms per strip. However, for objects that are nearby in R.A., the image motion is highly correlated and their relative positions are good to 0.02" rms per strip. We will show that the effects of atmospheric image motion on a given strip can be removed if a sufficient number of strips of a given area have been obtained. Thus, it is possible to reach an rms precision of 0.02" per strip, corresponding to about 0.3 of Pluto or Triton's angular radius. The ultimate accuracy of a prediction based on strip-scanning astrometry is currently limited by the accuracy of the positions of the stars in the astrometric network used and by systematic errors most likely due to the optical system. We will show the results of . the prediction of some recent occultations as examples of the current capabilities and limitations of this technique.

  10. Efficacy of benazepril hydrochloride to delay the progression of occult dilated cardiomyopathy in Doberman Pinschers.

    PubMed

    O'Grady, M R; O'Sullivan, M L; Minors, S L; Horne, R

    2009-01-01

    Angiotensin converting enzyme inhibitors (ACEIs) are recommended in people to treat asymptomatic (occult) dilated cardiomyopathy (DCM). Efficacy of therapy in occult DCM in dogs is unknown. ACEIs, specifically benazepril hydrochloride (BH), will delay the onset of overt DCM in Doberman Pinschers. Ninety-one Doberman Pinschers were studied, 57 dogs received BH, and 34 dogs no ACEI. Retrospective study of the medical records of all Doberman Pinschers with occult DCM that received BH or no ACEI between April 1989 and February 2003. Two criteria of left ventricular enlargement were used for enrollment: one independent of body weight (BW) (C1) and the other indexed to BW (C2). Cox proportional hazards analyses were used to identify variables associated with the onset of overt DCM. On univariate analysis the median time to onset of overt DCM was significantly longer for the benazepril group (for C1: 425 days for BH, 95% confidence interval [CI] 264-625 days; 339 days for no ACEI, CI 172-453 days, P= .02; for C2: 454 days for BH, CI 264-628 days; 356 days for no ACEI, CI 181-547 days, P= .02). The hazard ratio (HR) (benazepril/no ACEI) was 0.57, CI 0.35-0.94, P= .03 for C1; HR = 0.56, CI 0.34-0.93, P= .02 for C2. On multivariate analysis, BH significantly delayed onset of overt DCM (HR [benazepril/no ACEI] = 0.45, CI 0.26-0.78, P < .01, for C1; HR = 0.36, CI 0.21-0.63, P < .01, for C2). BH in particular and ACEIs in general might delay the progression of occult DCM. Prospective studies are warranted to test this theory.

  11. Pluto's Atmosphere, Then and Now

    NASA Astrophysics Data System (ADS)

    Elliot, J. L.; Buie, M.; Person, M. J.; Qu, S.

    2002-09-01

    The KAO light curve for the 1988 stellar occultation by Pluto exhibits a sharp drop just below half light, but above this level the light curve is consistent with that of an isothermal atmosphere (T = 105 +/- 8 K, with N2 as its major constituent). The sharp drop in the light curve has been interpreted as being caused by: (i) a haze layer, (ii) a large thermal gradient, or (iii) some combination of these two. Modeling Pluto's atmosphere with a haze layer yields a normal optical depth >= 0.145 (Elliot & Young 1992, AJ 103, 991). On the other hand, if Pluto's atmosphere is assumed to be clear, the occultation light curve can be inverted with a new method that avoids the large-body approximations. Inversion of the KAO light curve with this method yields an upper isothermal part, followed by a sharp thermal gradient that reaches a maximum magnitude of -3.9 +/- 0.6 K km-1 at the end of the inversion (r = 1206 +/- 10 km). Even though we do not yet understand the cause of the sharp drop, the KAO light curve can be used as a benchmark for examining subsequent Pluto occultation light curves to determine whether Pluto's atmospheric structure has changed since 1988. As an example, the Mamiña light curve for the 2002 July 20 Pluto occultation of P126A was compared with the KAO light curve by Buie et al. (this conference), who concluded that Pluto's atmospheric structure has changed significantly since 1988. Further analysis and additional light curves from this and subsequent occultations (e.g. 2002 August 21) will allow us to elucidate the nature of these changes. This work was supported, in part, by grants from NASA (NAG5-9008 and NAG5-10444) and NSF (AST-0073447).

  12. Spinal ultrasound in patients with anorectal malformations: is this the end of an era?

    PubMed

    Scottoni, Federico; Iacobelli, Barbara Daniela; Zaccara, Antonio Maria; Totonelli, Giorgia; Schingo, Antonio Maria Salvatore; Bagolan, Pietro

    2014-08-01

    Even if lumbar magnetic resonance imaging (MRI) is considered the gold standard in the diagnosis of occult spinal dysraphism (SD) in patients with anorectal malformations (ARMs), spinal ultrasound (US) performed up to 5 months of life have been largely used as a screening test. The aim of the present study was to evaluate the accuracy in terms of sensibility and specificity of neonatal US to detect occult SD in patients with ARMs. Retrospective analysis of all patients treated for ARMs between 1999 and 2013 at our institution who underwent both spinal US (up to 5 months of life) and MRI. Sensibility and specificity have been calculated for US based on MRI results. Of 244 patients treated for ARMs at our institution, 82 (34 females, 48 males) underwent both the imaging studies and have been included in this study. ARMs types were: anal stenosis (7), recto-vestibular fistula (19), recto-perineal fistula (3) and cloaca (5) in female and imperforate anus (7) recto-perineal fistula (14), recto-urethral fistula (22), recto-vesical fistula (5) in males. Forty-seven patients (57, 3 % of total, 18 females, 29 males) had some occult SD (tethered spinal cord, spinal lipoma, syringomyelia) at MRI. Only 7 (14, 8 %) patients of those with spinal anomalies at MRI had pathological US studies. In our population, sensibility and specificity of US for diagnosis of occult SD were, respectively, 14, 8 and 100 %. Since it is well known that a screening test must have a high sensibility, our data suggest that spinal ultrasound is not suitable as a screening test for occult spinal dysraphism in patients with ARMs. Furthermore, we strongly advise against the use of US as a screening test for spinal dysraphism to prevent a false sense of security in physician and patients' families.

  13. Cost effectiveness of the addition of a comprehensive CT scan to the abdomen and pelvis for the detection of cancer after unprovoked venous thromboembolism.

    PubMed

    Coyle, Kathryn; Carrier, Marc; Lazo-Langner, Alejandro; Shivakumar, Sudeep; Zarychanski, Ryan; Tagalakis, Vicky; Solymoss, Susan; Routhier, Nathalie; Douketis, James; Coyle, Douglas

    2017-03-01

    Unprovoked venous thromboembolism (VTE) can be the first manifestation of cancer. It is unclear if extensive screening for occult cancer including a comprehensive computed tomography (CT) scan of the abdomen/pelvis is cost-effective in this patient population. To assess the health care related costs, number of missed cancer cases and health related utility values of a limited screening strategy with and without the addition of a comprehensive CT scan of the abdomen/pelvis and to identify to what extent testing should be done in these circumstances to allow early detection of occult cancers. Cost effectiveness analysis using data that was collected alongside the SOME randomized controlled trial which compared an extensive occult cancer screening including a CT of the abdomen/pelvis to a more limited screening strategy in patients with a first unprovoked VTE, was used for the current analyses. Analyses were conducted with a one-year time horizon from a Canadian health care perspective. Primary analysis was based on complete cases, with sensitivity analysis using appropriate multiple imputation methods to account for missing data. Data from a total of 854 patients with a first unprovoked VTE were included in these analyses. The addition of a comprehensive CT scan was associated with higher costs ($551 CDN) with no improvement in utility values or number of missed cancers. Results were consistent when adopting multiple imputation methods. The addition of a comprehensive CT scan of the abdomen/pelvis for the screening of occult cancer in patients with unprovoked VTE is not cost effective, as it is both more costly and not more effective in detecting occult cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Occult Radiographically Evident Port-Site Hernia After Robot-Assisted Urologic Surgery: Incidence and Risk Factors.

    PubMed

    Christie, Matthew C; Manger, Jules P; Khiyami, Abdulaziz M; Ornan, Afshan A; Wheeler, Karen M; Schenkman, Noah S

    2016-01-01

    Laparoscopic trocar-site hernias (TSH) are rare, with a reported incidence of 1% or less. The incidence of occult radiographically evident hernias has not been described after robot-assisted urologic surgery. We evaluated the incidence and risk factors of this problem. A single-institution retrospective review of robot-assisted urologic surgery was performed from April 2009 to December 2012. Patients with preoperative and postoperative CT were included for analysis. Imaging was reviewed by two radiologists and one urologist. One hundred four cases were identified, including 60 partial nephrectomy, 38 prostatectomy, and 6 cystectomy. Mean age was 58 years and mean body mass index (BMI) was 29 kg/m(2). The cohort was 77% male. Ten total hernias were identified by CT in 8 patients, 2 of which were clinically evident hernias. Excluding these two hernias, occult port-site hernias were identified radiographically in seven patients. Per-patient incidence of occult TSH was 6.7% (7/104), and per-port incidence was 1.4% (8/564). All hernias were midline and 30% contained bowel. Eight of the 10 occurred at 12 mm sites (p = 0.0065) and 3 of the 10 occurred at extended incisions. Age, gender, BMI, smoking status, diabetes mellitus, immunosuppressive drug therapy, ASA score, procedure, blood loss, prior abdominal surgery, and history of hernia were not significant risk factors. Specimen size >40 g (p = 0.024) and wound infection (p = 0.0052) were significant risk factors. While the incidence of clinically evident port-site hernia remains low in robot-assisted urologic surgery, the incidence of CT-detected occult hernia was 6.7% in this series. These occurred most often in sites extended for specimen extraction and at larger port sites. This suggests more attention should be paid to fascial closure at these sites.

  15. RECON - A new system for probing the outer solar system with stellar occultations

    NASA Astrophysics Data System (ADS)

    Buie, M. W.; Keller, J. M.; Wasserman, L. H.

    2015-10-01

    The Research and Education Collaborative Occultation Network (RECON) is a new system for coordinated occultation observations of outer solar system objects. Occultations by objects in the outer solar system are more difficult to predict due to their large distance and limited duration of the astrometric data used to determine their orbits and positions. This project brings together the research and educational community into a unique citizen-science partnership to overcome the difficulties of observing these distant objects. The goal of the project is to get sizes and shapes for TNOs with diameters larger than 100 km. As a result of the system design it will also serve as a probe for binary systems with spatial separations too small to be resolved directly. Our system takes the new approach of setting up a large number of fixed observing stations and letting the shadows come to the network. The nominal spacing of the stations is 50 km. The spread of the network is roughly 2000 km along a roughly north-south line in the western United States. The network contains 56 stations that are committed to the project and we get additional ad hoc support from the International Occultation Timing Association. At our minimum size, two stations will record an event while the other stations will be probing for secondary events. Larger objects will get more chords and will allow determination of shape profiles. The stations are almost exclusively sited and associated with schools, usually at the 9-12 grade level. We have successfully completed our first TNO observation which is presented in the compainion paper by G. Rossi et al (this conference).

  16. Observations of Time Variable Magnitude Events of Phoebe, Ariel, and Titania

    NASA Astrophysics Data System (ADS)

    Miller, Charles; Chanover, N. J.; Holtzman, J. A.; Verbiscer, A. J.

    2007-10-01

    Visual observations of Saturn's moon Phoebe and Uranus' moons Ariel and Titania were made from the Apache Point Observatory (APO). Phoebe was observed with the APO 1 meter telescope over a two month period from 06 January to 04 March 2005, bracketing the zero-phase opposition on 13 January 2005. Phoebe was observed at Sun-Phoebe-Earth phase angles as low as 0.05 degrees on consecutive nights immediately before and after opposition in V, B, R, and I filters. Light curves of the opposition surge, the brightness increase that occurs as the phase angle drops below 0.10 degrees, are presented from this data. The data were processed using standard IRAF aperture photometry image processing techniques. The magnitude and duration of the opposition surge provide clues about the grain size of surface particles on Phoebe. Observations were also made of Uranian moons during mutual occultations in August 2007. Mutual satellite occultations are taking place throughout 2007 as Uranus passes through its equinox, which occurs once every 42 years. The timing and flux variation of satellite occultations provide a check on the accuracy of satellite orbital models. Light curves for Ariel and Titania in R and I filters as they are occulted by Umbriel are presented from data acquired with the APO 1 meter and 3.5 meter telescopes. Comparison is made to the predicted total flux reduction and event timing for each occultation as calculated by the Institut de Mecanique Celeste et de Calcul des Ephemerides (IMCCE) and implications of the results on determination of the relative orbital inclinations of Umbriel, Ariel, and Titania are discussed. This work was supported by an NMSU Space and Aerospace Research Cluster Graduate Fellowship .

  17. Serendipitous occultations by kilometer size Kuiper Belt with MIOSOTYS

    NASA Astrophysics Data System (ADS)

    Doressoundiram, A.; Liu, C.-Y.; Maquet, L.; Roques, F.

    2017-09-01

    MIOSOTYS (Multi-object Instrument for Occultations in the SOlar system and TransitorY Systems) is a multi-fiber positioner coupled with a fast photometry camera. This is a visitor instrument mounted on the 193 cm telescope at the Observatoire de Haute-Provence, France and on the 123 cm telescope at the Calar Alto Observatory, Spain. Our immediate goal is to characterize the spatial distribution and extension of the Kuiper Belt, and the physical size distribution of TNOs. We present the observation campaigns during 2010-2013, objectives and observing strategy. We report the detection of potential candidates for occultation events of TNOs. We will discuss more specifically the method used to process the data and the modelling of diffraction patterns. We, finally present the results obtained concerning the distribution of sub-kilometer TNOs in the Kuiper Belt.

  18. No evidence of rings around Neptune

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Mink, D. J.; Baron, R. L.; Dunham, E.; Pingree, J. E.; French, R. G.; Elias, J. H.; Liller, W.; Nicholson, P. D.; Jones, T. J.

    1981-01-01

    The results of two observations of stellar occultations of Neptune to determine if the planet has a ring system are reported. The sightings were made from Mt. Stromlo, Mauna Kea, and Cerro Tololo, noting that an equatorial ring would subtend only two arcsec of view. An upper accretion limit was defined to set the region around Neptune where rings, rather than satellites, could form. The intensities of the starlight from the two selected stars were recorded by photometers on magnetic tape during the occultation period. One of the stars did not occult, but passed through the entire region where a ring system might be present. No definitive evidence for rings was found, although an optical depth for a Neptunian ring was calculated at 0.07, with a width of more than 5 km and a radius of 31,400 km.

  19. Unsuspected Active Ulcerative Colitis in a Patient With Dermatomyositis: A Rare Association Detected on 18F-FDG PET/CT During the Search for an Occult Malignancy.

    PubMed

    Rayamajhi, Sampanna Jung; Gorla, Arun Kumar Reddy; Basher, Rajender Kumar; Sood, Ashwani; Mittal, Bhagwant Rai

    2017-01-01

    Dermatomyositis is an inflammatory myopathy with the characteristic features of skin rash and myopathy. We here present a known case of dermatomyositis evaluated with 18 F-FDG PET/CT for the presence of any occult malignancy. The scan was negative for the presence of any malignancy. However, it revealed multiple intensely FDG avid colonic strictures that were later proven on colonoscopic biopsy to be ulcerative colitis. Also, a well-known association of bilateral sacroilitis was simultaneously demonstrated on the scan. The present case demonstrates that 18 F-FDG PET/CT imaging can serve as a one-stop shop imaging modality in dermatomyositis by facilitating detection of occult primary if any and by providing insight into other rare systemic associations.

  20. Unsuspected Active Ulcerative Colitis in a Patient With Dermatomyositis: A Rare Association Detected on 18F-FDG PET/CT During the Search for an Occult Malignancy

    PubMed Central

    Rayamajhi, Sampanna Jung; Gorla, Arun Kumar Reddy; Basher, Rajender Kumar; Sood, Ashwani; Mittal, Bhagwant Rai

    2017-01-01

    Dermatomyositis is an inflammatory myopathy with the characteristic features of skin rash and myopathy. We here present a known case of dermatomyositis evaluated with 18F-FDG PET/CT for the presence of any occult malignancy. The scan was negative for the presence of any malignancy. However, it revealed multiple intensely FDG avid colonic strictures that were later proven on colonoscopic biopsy to be ulcerative colitis. Also, a well-known association of bilateral sacroilitis was simultaneously demonstrated on the scan. The present case demonstrates that 18F-FDG PET/CT imaging can serve as a one-stop shop imaging modality in dermatomyositis by facilitating detection of occult primary if any and by providing insight into other rare systemic associations. PMID:28533643

  1. Gamma-ray monitoring of AGN and galactic black hole candidates by the Gamma-Ray Observatory

    NASA Technical Reports Server (NTRS)

    Wheaton, Wm. A.; Ling, James C.; Skelton, R. T.; Harmon, Alan; Fishman, Gerald J.; Meegan, Charles A.; Paciesas, William S.; Rubin, Brad; Wilson, Robert B.; Gruber, Duane E.

    1992-01-01

    The Burst and Transient Spectroscopy Experiment (BATSE) on the Compton Gamma-Ray Observatory has a powerful capability to provide nearly uninterrupted monitoring in the 25 keV-10 MeV range of both AGN and Galactic black hole candidates such as Cygnus X-1, using the occultation of cosmic sources by the Earth. Progress in background modeling indicates that the data accept region, or fit window tau, around the occultation step can be substantially increased over that conservatively assumed in earlier estimates of BATSE's Earth occultation sensitivity. We show samples of large-tau fits to background and source edges. As a result we expect to be able to perform long-term monitoring of Cygnus X-1 and many of the brighter AGN for the duration of the CGRO mission.

  2. The future of stellar occultations by distant solar system bodies: Perspectives from the Gaia astrometry and the deep sky surveys

    NASA Astrophysics Data System (ADS)

    Camargo, J. I. B.; Desmars, J.; Braga-Ribas, F.; Vieira-Martins, R.; Assafin, M.; Sicardy, B.; Bérard, D.; Benedetti-Rossi, G.

    2018-05-01

    Distant objects in the solar system are crucial to better understand the history and evolution of its outskirts. The stellar occultation technique allows the determination of their sizes and shapes with kilometric accuracy, a detailed investigation of their immediate vicinities, as well as the detection of tenuous atmospheres. The prediction of such events is a key point in this study, and yet accurate enough predictions are available to a handful of objects only. In this work, we briefly discuss the dramatic impact that both the astrometry from the Gaia space mission and the deep sky surveys - the Large Synoptic Survey Telescope in particular - will have on the prediction of stellar occultations and how they may influence the future of the study of distant small solar system bodies through this technique.

  3. First results from the Cassini radio occultations of the Titan ionosphere

    NASA Astrophysics Data System (ADS)

    Kliore, Avydas J.; Nagy, Andrew F.; Marouf, Essam A.; French, Richard G.; Flasar, F. Michael; Rappaport, Nicole J.; Anabttawi, Aseel; Asmar, Sami W.; Kahann, Daniel S.; Barbinis, Elias; Goltz, Gene L.; Fleischman, Don U.; Rochblatt, David J.

    2008-09-01

    The first four sets of radio occultations of the Titan's ionosphere were obtained by the Cassini spacecraft between March 2006 and May 2007. These occultations occurred at middle and high latitudes, at solar zenith angles from about 86° to 96°. The main ionospheric peak was seen, as expected from modeling and previous observations, near 1200 km, with a density of about 1-3 × 103 cm-3. A consistent ledge near 1000 km was also seen, and one of the polar observations found a significant (˜3 × 103 cm-3) layer in the region of 500-600 km. This layer also is seen in other observations with a density varying from about 0.7 to 1.7 × 103 cm-3, suggesting a variable production source (or sources) for this peak.

  4. Uranus and the shape of elliptical rings

    NASA Technical Reports Server (NTRS)

    Lucke, R. L.

    1978-01-01

    It is reported that when the star SAO158687 passed behind the Uranus system, its light was occulted twice by the epsilon (fifth) ring of the planet. The first part of the ring to occult was about 100 km wide and the second part was about 40 km wide. The variable width of the ring is accounted for by differences in the orbital eccentricities of the individual particles composing the ring.

  5. Studies of planetary upper atmospheres through occultations

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.

    1982-01-01

    The structure, composition, dynamics and energy balance of planetary upper atmospheres through interpretation of steller occultation data from Uranus is discussed. The wave-optical problem of modelling strong scintillation for arbitrary turbulent atmospheres is studied, as well as influence of turbulence. It was concluded that quasi-global features of atmospheric structure are accurately determined by numerical inversion. Horizontally inhomogeneous structures are filtered out and have little effect on temperature profiles.

  6. [Results of conservative treatment in patients with occult pneumothorax].

    PubMed

    Llaquet Bayo, Heura; Montmany Vioque, Sandra; Rebasa, Pere; Navarro Soto, Salvador

    2016-04-01

    An occult pneumothorax is found in 2-15% trauma patients. Observation (without tube thoracostomy) in these patients presents still some controversies in the clinical practice. The objective of the study is to evaluate the efficacy and the adverse effects when observation is performed. A retrospective observational study was undertaken in our center (university hospital level II). Data was obtained from a database with prospective registration. A total of 1087 trauma patients admitted in the intensive care unit from 2006 to 2013 were included. In this period, 126 patients with occult pneumothorax were identified, 73 patients (58%) underwent immediate tube thoracostomy and 53 patients (42%) were observed. Nine patients (12%) failed observation and required tube thoracostomy for pneumothorax progression or hemothorax. No patient developed a tension pneumothorax or experienced another adverse event related to the absence of tube thoracostomy. Of the observed patients 16 were under positive pressure ventilation, in this group 3 patients (19%) failed observation. There were no differences in mortality, hospital length of stay or intensive care length of stay between the observed and non-observed group. Observation is a safe treatment in occult pneumothorax, even in pressure positive ventilated patients. Copyright © 2014 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Asteroid astrometry with Gaia: stellar occultations and beyond

    NASA Astrophysics Data System (ADS)

    Tanga, Paolo; Spoto, Federica; Hestroffer, Daniel; Altmann, Martin; Bouquillon, Sebastien; Desmars, Josselin

    2017-10-01

    The first data release of star astrometry by Gaia (Sept. 2016) has given an anticipation of the mission capabilities. By providing positions with uncertainties at the level of few milli-arcsec (mas) a new frame to calibrate ground-based observations has immediately become available, thus disclosing a new possibility of exploitation for archive data. We will discuss, in particular, the new role of stellar occulations.Successful observations of occultations have been used in the past to provide accurate shape and size of the targets and to calibrate other size determination methods. Now, a new possibility of exploitation exists, as occultation astrometry provides the possibility of measuring precise asteroid position, at the level of Gaia accuracy. This approach will have an increasing impact, also thanks to the much improved prediction accuracy that Gaia is going to provide, for smaller asteroids and fainter target stars.The scientific goals of improving asteroid astrometry are multiple. For instance, reaching sensitivity to Yarkovsky drift in the Main Belt might become possible, by occultation astrometry performed on smaller asteroids, thanks to future Gaia predictions.The second data release (April 2018) will also contain astrometry of asteroids observed directly by Gaia. The properties of this new data set, that will permit direct orbit improvement, will be illustrated.

  8. Titan's Upper Atmosphere from Cassini/UVIS Solar Occultations

    NASA Astrophysics Data System (ADS)

    Capalbo, Fernando J.; Bénilan, Yves; Yelle, Roger V.; Koskinen, Tommi T.

    2015-12-01

    Titan’s atmosphere is composed mainly of molecular nitrogen, methane being the principal trace gas. From the analysis of 8 solar occultations measured by the Extreme Ultraviolet channel of the Ultraviolet Imaging Spectrograph (UVIS) on board Cassini, we derived vertical profiles of N2 in the range 1100-1600 km and vertical profiles of CH4 in the range 850-1300 km. The correction of instrument effects and observational effects applied to the data are described. We present CH4 mole fractions, and average temperatures for the upper atmosphere obtained from the N2 profiles. The occultations correspond to different times and locations, and an analysis of variability of density and temperature is presented. The temperatures were analyzed as a function of geographical and temporal variables, without finding a clear correlation with any of them, although a trend of decreasing temperature toward the north pole was observed. The globally averaged temperature obtained is (150 ± 1) K. We compared our results from solar occultations with those derived from other UVIS observations, as well as studies performed with other instruments. The observational data we present confirm the atmospheric variability previously observed, add new information to the global picture of Titan’s upper atmosphere composition, variability, and dynamics, and provide new constraints to photochemical models.

  9. Distributions and Seasonal Variations of Tropospheric Ethene (C2H4) from Atmospheric Chemistry Experiment (ACE-FTS) Solar Occultation Spectra

    NASA Technical Reports Server (NTRS)

    Herbin, H.; Hurtmans, D.; Clarisse, L.; Turquety, S.; Clerbaux, C.; Rinsland, Curtis P.; Boone, C.; Bernath, P. F.; Coheur, P.-F.

    2009-01-01

    This work reports the first measurements of ethene (C2H4) distributions in the upper troposphere. These are obtained by retrieving vertical profiles from 5 to 20 km from infrared solar occultation spectra recorded in 2005 and 2006 by the Atmospheric Chemistry Experiment-Fourier Transform Spectrometer (ACE-FTS). Background volume mixin^ ratios (vmrs) ranging from a few to about 50 pptv (10(exp -1) are measured at the different altitudes, while for certain occultations, vmrs as high as 200 pptv are observed. Zonal distributions and vertically resolved latitudinal distributions are derived for the two year period analyzed, highlighting spatial - including a North-South gradient - as well as seasonal variations. We show the latter to be more pronounced at the highest latitudes, presumably as a result of less active photochemistry during winter. The observation of C2H4 enhancements in remote Arctic regions at high latitudes is consistent with the occurrence of fast transport processes of gaseous pollution from the continents leading to Arctic haze. Citation: Herbin, H., D. Hurtmans, L. Clarisse, S. Turquety, C. Clerbaux, C. P. Rinsland, C. Boone, P. F. Bernath, and P.-F. Colieur (2009), Distributions and seasonal variations of tropospheric ethene (C2H4) from Atmospheric Chemistry Experiment (ACE-FTS) solar occultation spectra,

  10. Blastic plasmacytoid dendritic cell neoplasm frequently shows occult central nervous system involvement at diagnosis and benefits from intrathecal therapy.

    PubMed

    Martín-Martín, Lourdes; Almeida, Julia; Pomares, Helena; González-Barca, Eva; Bravo, Pilar; Giménez, Teresa; Heras, Cecilia; Queizán, José-Antonio; Pérez-Ceballos, Elena; Martínez, Violeta; Alonso, Natalia; Calvo, Carlota; Álvarez, Rodolfo; Caballero, María Dolores; Orfao, Alberto

    2016-03-01

    Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is a rare aggressive myeloid neoplasm which shows a high rate of central nervous system (CNS) recurrence and overall survival (OS) of <1 year. Despite this, screening for CNS involvement is not routinely performed at diagnosis and intrathecal (IT) prophylaxis is not regularly administered in BPDCN. Here, we prospectively evaluated 13 consecutive BPDCN patients for the presence of CNS involvement by flow cytometry. Despite none of the patients presented with neurological symptoms, occult CNS involvement was detected in 6/10 cases evaluated at diagnosis and 3/3 studied at relapse/progression. BPDCN patients evaluated at diagnosis received IT treatment -either CNS prophylaxis (n = 4) or active therapy (n = 6)- and all but one remain alive (median follow-up of 20 months). In contrast, all three patients assessed at relapse/progression died. The potential benefit of IT treatment administered early at diagnosis on OS and CNS recurrence-free survival of BPDCN was further confirmed in a retrospective cohort of another 23 BPDCN patients. Our results show that BPDCN patients studied at diagnosis frequently display occult CNS involvement; moreover, they also indicate that treatment of occult CNS disease might lead to a dramatically improved outcome of BPDCN.

  11. Verify Occulter Deployment Tolerances as Part of NASA's Technology Development for Exoplanet Missions

    NASA Astrophysics Data System (ADS)

    Kasdin, N. J.; Shaklan, S.; Lisman, D.; Thomson, M.; Webb, D.; Cady, E.; Marks, G. W.; Lo, A.

    2013-01-01

    In support of NASA's Exoplanet Exploration Program and the Technology Development for Exoplanet Missions (TDEM), we recently completed a 2 year study of the manufacturability and metrology of starshade petals. An external occult is a satellite employing a large screen, or starshade, that flies in formation with a spaceborne telescope to provide the starlight suppression needed for detecting and characterizing exoplanets. Among the advantages of using an occulter are the broadband allowed for characterization and the removal of light before entering the observatory, greatly relaxing the requirements on the telescope and instrument. This poster presents the results of our successful first TDEM that demonstrated an occulter petal could be built and measured to an accuracy consistent with close to 10^-10 contrast. We also present the progress in our second TDEM to demonstrate the next critical technology milestone: precision deployment of the central truss and petals to the necessary accuracy. We have completed manufacture of four sub-scale petals and a central hub to fit with an existing deployable truss. We show the plans for repeated stow and deploy tests of the assembly and the metrology to confirm that each deploy repeatably meets the absolute positioning requirements of the petals (better than 1.0 mm).

  12. Testing Starshade Manufacturing and Deployment Through NASA's Technology Development for Exoplanet Missions Program

    NASA Astrophysics Data System (ADS)

    Kasdin, N. J.; Shaklan, S.; Lisman, D.; Thomson, M.; Cady, E.; Lo, A.; Macintosh, B.

    2014-01-01

    An external occulter is a satellite employing a large screen, or starshade, that flies in formation with a spaceborne telescope to provide the starlight suppression needed for detecting and characterizing exoplanets. Among the advantages of using an occulter are the broadband allowed for characterization and the removal of light before entering the observatory, greatly relaxing the requirements on the telescope and instrument. In this poster we report on the results of our two Technology Development for Exoplanet Missions (TDEM) studies. In the first we examined the manufacturability and metrology of starshade petals, successfully constructing a full size petal from flight like materials and showing through precise edge shape measurements that an occulter made with petals consistent with the measured accuracy would achieve close to 10^-10 contrast. Our second TDEM tested the deployment precision of a roughly half-scale starshade. We demonstrated the deployment of an existing deployable truss outfitted with four sub-scale petals and a custom designed central hub. We showed that the system can be deployed multiple times with a repeatable positioning accuracy of the petals better than the requirement of 1.0 mm. The combined results of these two TDEM projects has significantly advanced the readiness level of occulter technology and moved the community closer to a realizable mission.

  13. Blastic plasmacytoid dendritic cell neoplasm frequently shows occult central nervous system involvement at diagnosis and benefits from intrathecal therapy

    PubMed Central

    Martín-Martín, Lourdes; Almeida, Julia; Pomares, Helena; González-Barca, Eva; Bravo, Pilar; Giménez, Teresa; Heras, Cecilia; Queizán, José-Antonio; Pérez-Ceballos, Elena; Martínez, Violeta; Alonso, Natalia; Calvo, Carlota; Álvarez, Rodolfo; Caballero, María Dolores; Orfao, Alberto

    2016-01-01

    Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is a rare aggressive myeloid neoplasm which shows a high rate of central nervous system (CNS) recurrence and overall survival (OS) of <1 year. Despite this, screening for CNS involvement is not routinely performed at diagnosis and intrathecal (IT) prophylaxis is not regularly administered in BPDCN. Here, we prospectively evaluated 13 consecutive BPDCN patients for the presence of CNS involvement by flow cytometry. Despite none of the patients presented with neurological symptoms, occult CNS involvement was detected in 6/10 cases evaluated at diagnosis and 3/3 studied at relapse/progression. BPDCN patients evaluated at diagnosis received IT treatment -either CNS prophylaxis (n = 4) or active therapy (n = 6)- and all but one remain alive (median follow-up of 20 months). In contrast, all three patients assessed at relapse/progression died. The potential benefit of IT treatment administered early at diagnosis on OS and CNS recurrence-free survival of BPDCN was further confirmed in a retrospective cohort of another 23 BPDCN patients. Our results show that BPDCN patients studied at diagnosis frequently display occult CNS involvement; moreover, they also indicate that treatment of occult CNS disease might lead to a dramatically improved outcome of BPDCN. PMID:26840087

  14. Size of Self-Gravity Wakes from Cassini UVIS Tracking Occultations and Ring Transparency Statistics

    NASA Astrophysics Data System (ADS)

    Esposito, Larry W.; Rehnberg, Morgan; Colwell, Joshua E.; Sremcevic, Miodrag

    2017-10-01

    We compare two methods for determining the size of self-gravity wakes in Saturn’s rings. Analysis of gaps seen in UVIS occultations gives a power law distribution from 10-100m (Rehnberg etal 2017). Excess variance from UVIS occultations can be related to characteristic clump widths, a method which extends the work of Showalter and Nicholson (1990) to more arbitrary shadow distributions. In the middle A ring, we use results from Colwell etal (2017) for the variance and results from Jerousek etal (2016) for the relative size of gaps and wakes to estimate the wake width consistent with the excess variance observed there. Our method gives:W= sqrt (A) * E/T2 * (1+ S/W)Where A is the area observed by UVIS in an integration period, E is the measured excess variance above Poisson statistics, T is the mean transparency, and S and W are the separation and width of self-gravity wakes in the granola bar model of Colwell etal (2006). We find:W ~ 10m and infer the wavelength of the fastest growing instabilityLambda(TOOMRE) = S + W ~ 30m.This is consistent with the calculation of the Toomre wavelength from the surface mass density of the A ring, and with the highest resolution UVIS star occultations.

  15. Size of Self-Gravity Wakes from Cassini UVIS Tracking Occultations and Ring Transparency Statistics

    NASA Astrophysics Data System (ADS)

    Esposito, L. W.; Rehnberg, M.; Colwell, J. E.; Sremcevic, M.

    2017-12-01

    We compare two methods for determining the size of self-gravity wakes in Saturn's rings. Analysis of gaps seen in UVIS occultations gives a power law distribution from 10-100m (Rehnberg etal 2017). Excess variance from UVIS occultations can be related to characteristic clump widths, a method which extends the work of Showalter and Nicholson (1990) to more arbitrary shadow distributions. In the middle A ring, we use results from Colwell etal (2017) for the variance and results from Jerousek etal (2016) for the relative size of gaps and wakes to estimate the wake width consistent with the excess variance observed there. Our method gives: W= sqrt (A) * E/T2 * (1+ S/W)Where A is the area observed by UVIS in an integration period, E is the measured excess variance above Poisson statistics, T is the mean transparency, and S and W are the separation and width of self-gravity wakes in the granola bar model of Colwell etal (2006). We find: W 10m and infer the wavelength of the fastest growing instability lamdaT = S + W 30m. This is consistent with the calculation of the Toomre wavelength from the surface mass density of the A ring, and with the highest resolution UVIS star occultations.

  16. DETECTION OF THERMAL EMISSION FROM A SUPER-EARTH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demory, Brice-Olivier; Seager, Sara; Benneke, Bjoern

    2012-06-01

    We report on the detection of infrared light from the super-Earth 55 Cnc e, based on four occultations obtained with Warm Spitzer at 4.5 {mu}m. Our data analysis consists of a two-part process. In a first step, we perform individual analyses of each data set and compare several baseline models to optimally account for the systematics affecting each light curve. We apply independent photometric correction techniques, including polynomial detrending and pixel mapping, that yield consistent results at the 1{sigma} level. In a second step, we perform a global Markov Chain Monte Carlo analysis, including all four data sets that yieldmore » an occultation depth of 131 {+-} 28 ppm, translating to a brightness temperature of 2360 {+-} 300 K in the IRAC 4.5 {mu}m channel. This occultation depth suggests a low Bond albedo coupled to an inefficient heat transport from the planetary day side to the night side, or else possibly that the 4.5 {mu}m observations probe atmospheric layers that are hotter than the maximum equilibrium temperature (i.e., a thermal inversion layer or a deep hot layer). The measured occultation phase and duration are consistent with a circular orbit and improves the 3{sigma} upper limit on 55 Cnc e's orbital eccentricity from 0.25 to 0.06.« less

  17. Measuring the Size of a Small, Frost World

    NASA Astrophysics Data System (ADS)

    2006-01-01

    Observing a very rare occultation of a star by Pluto's satellite Charon from three different sites, including Paranal, home of the VLT, astronomers were able to determine with great accuracy the radius and density of the satellite to the farthest planet. The density, 1.71 that of water, is indicative of an icy body with about slightly more than half of rocks. The observations also put strong constraints on the existence of an atmosphere around Charon. ESO PR Photo 02a/06 ESO PR Photo 02a/06 Artist's Impression of the Pluto-Charon system Since its discovery in 1978, Charon and Pluto have appeared to form a double planet, rather than a planet-satellite couple. Actually, Charon is about twice as small as Pluto in size, and about eight times less massive. However, there have been considerable discussions concerning the precise radii of Pluto and Charon, as well as about the presence of a tenuous atmosphere around Charon. In August 2004, Australian amateur astronomer Dave Herald predicted that the 15-magnitude star UCAC2 26257135 should be occulted by Charon on 11 July 2005. The occultation would be observable from some parts of South America, including Cerro Paranal, in the northern Atacama Desert, the location of ESO's Very Large Telescope (VLT). Stellar occultations have proved to be powerful tools to both measure sizes - at km-level accuracy, i.e. a factor ten better than what is feasible with other techniques - and detect very tenuous atmosphere - at microbar levels or less. Unfortunately, in the case of Charon, such occultations are extremely rare, owing to the very small angular diameter of the satellite on the sky: 55 milli-arcsec, i.e. the size of a one Euro coin observed from 100 km away! This explains why only one occultation by Charon was ever observed before 2005, namely on 7 April 1980 by Alistair Walker, from the South Africa Astronomical Observatory. Similarly, only in 1985, 1988 and 2002 could astronomers observe stellar occultations by Pluto. Quite surprisingly, the 2002 event showed that Pluto's atmospheric pressure had increased by a factor of two in four years (ESO PHOT 21/02). "Several factors, however, have boosted our odds for witnessing occultations of Charon," said Bruno Sicardy, from Paris Observatory (France) and lead author of the paper reporting the results. "First, larger telescopes now give access to fainter stars, thus multiplying the candidates for occultations. Secondly, stellar catalogues have become much more precise, allowing us to do better predictions. And, finally, the Pluto-Charon system is presently crossing the Milky Way, thereby increasing the likelihood of an occultation." ESO PR Photo 02b/06 ESO PR Photo 02b/06 The Pluto-Charon System (NACO/VLT) The July 2005 event was eventually observed from Paranal with Yepun, the fourth Unit Telescope of the VLT, equipped with the adaptive optics instrument NACO, as well as with the 0.5m "Campo Catino Austral Telescope" at San Pedro de Atacama (Chile), and with the 2.15m "Jorge Sahade" telescope at Cerro El Leoncito (Argentina). An accurate timing of the occultation seen at the three sites provides the most accurate measurement of Charon's size: its radius is found to be 603.6 km, with an error of the order of 5 km. This accuracy now allows astronomers to pin Charon's density down to 1.71 that of water, indicative of an icy body with about slightly more than half of rocks. Quite remarkably, Charon's density is now measured with much more precision than Pluto's. ESO PR Photo 02c/06 ESO PR Photo 02c/06 Charon's Occultation on July 11, 2005 Thanks to these observations, Sicardy and his collaborators could determine that if an tenuous atmosphere exists on Charon, linking it to the freezing ­-220­ degrees centigrade or so surface, its pressure has to be less than one tenth of a millionth that at the surface of the Earth, or 0.1 microbar, assuming that it is constituted entirely of nitrogen. A similar upper limit is derived for a gas like carbon monoxide. This is more than a factor one hundred smaller than Pluto's surface pressure, which is estimated to be in the range 10-15 microbars. "Comparing Pluto and Charon, we seem to cross a borderline between bodies which may have bound atmospheres - like Pluto - and airless bodies like Charon", said Olivier Hainaut, from ESO and member of the team. The observations also indicate that methane ice, if present, should be restricted to very cold regions of the surface. Similarly, nitrogen ice would be confined at best to high northern latitudes or permanently shadowed regions of Charon. As Pluto and its satellite sweep across the Milky Way, observations of more occultations will be tempted from the ground, while the NASA's Pluto-Kuiper Belt Mission, to be launched in January 2006, will be travelling towards the planet, that it should reach in July 2015. A report of these results is to be published in the January 5, 2006 issue of Nature ("Charon's size and upper limit on its atmosphere from a stellar occultation", by B. Sicardy, A. Bellucci, E. Gendron, F. Lacombe, S. Lacour, J. Lecacheux, E. Lellouch, S. Renner, S. Pau, F. Roques, T. Widemann, F. Colas, F. Vachier, N. Ageorges, O. Hainaut, O. Marco, W. Beisker, E. Hummel, C. Feinstein, H. Levato, A. Maury, E. Frappa, B. Gaillard, M. Lavayssière, M. Di Sora, F. Mallia, G. Masi, R. Behrend, F. Carrier, O. Mousis, P. Rousselot, A. Alvarez-Candal, D. Lazzaro, C. Veiga, A.H. Andrei, M. Assafin, D.N. da Silva Neto, R. Vieira Martins, C. Jacques, E. Pimentel, D. Weaver, J.-F Lecampion, F. Doncel, T. Momiyama, and G. Tancredi). High resolution images and their captions are available on this page.

  18. [Occult pneumothorax: Does it take drain before elective surgery?].

    PubMed

    Bensghir, M; Moutaoukil, M; Meziane, M; Jaafari, A; Hemmaoui, B; Haimeur, C

    2016-08-01

    Pneumothorax occult is defined by the presence of a non-visible to standard asymptomatic pneumothorax and pulmonary diagnosed only by X-ray computed tomography. The presence of this type of pneumothorax before planned surgery is a rare situation. What to do remains non-consensual. Through two clinic cases and a literature review, the authors discuss the modalities of management of this entity. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Ionospheric Signatures in Radio Occultation Data

    NASA Technical Reports Server (NTRS)

    Mannucci, Anthony J.; Ao, Chi; Iijima, Byron A.; Kursinkski, E. Robert

    2012-01-01

    We can extend robustly the radio occultation data record by 6 years (+60%) by developing a singlefrequency processing method for GPS/MET data. We will produce a calibrated data set with profile-byprofile data characterization to determine robust upper bounds on ionospheric bias. Part of an effort to produce a calibrated RO data set addressing other key error sources such as upper boundary initialization. Planned: AIRS-GPS water vapor cross validation (water vapor climatology and trends).

  20. Scintigraphic detection of occult hemorrhage using RBCs labeled in vitro with technetium Tc 99m sodium pertechnetate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bunker, S.R.; Kolina, J.S.; Kaplan, K.A.

    1983-05-01

    Scintigraphy with RBCs labeled with technetium Tc 99m sodium pertechnetate effectively located the source of hemorrhage in a patient receiving long-term anticoagulant therapy. (The patient was initially seen with a large hematoma on the flank.) More important, the procedure was used to monitor activity in this otherwise-occult bleeding site. Scintigraphic studies may be useful in the management of these difficult clinical problems.

  1. Errors incurred in profile reconstruction and methods for increasing inversion accuracies for occultation type measurements

    NASA Technical Reports Server (NTRS)

    Gross, S. H.; Pirraglia, J. A.

    1972-01-01

    A method for augmenting the occultation experiment is described for slightly refractive media. This method which permits separation of the components of the gradient of refractivity, appears applicable to most of the planets for a major portion of their atmospheres and ionospheres. The analytic theory is given, and the results of numerical tests with a radially and angularly varying model of an ionosphere are discussed.

  2. Preview of the BATSE Earth Occultation Catalog of Low Energy Gamma Ray Sources

    NASA Technical Reports Server (NTRS)

    Harmon, B. A.; Wilson, C. A.; Fishman, G. J.; McCollough, M. L.; Robinson, C. R.; Sahi, M.; Paciesas, W. S.; Zhang, S. N.

    1999-01-01

    The Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma Ray Observatory (CGRO) has been detecting and monitoring point sources in the high energy sky since 1991. Although BATSE is best known for gamma ray bursts, it also monitors the sky for longer-lived sources of radiation. Using the Earth occultation technique to extract flux information, a catalog is being prepared of about 150 sources potential emission in the large area detectors (20-1000 keV). The catalog will contain light curves, representative spectra, and parametric data for black hole and neutron star binaries, active galaxies, and super-nova remnants. In this preview, we present light curves for persistent and transient sources, and also show examples of what type of information can be obtained from the BATSE Earth occultation database. Options for making the data easily accessible as an "on line" WWW document are being explored.

  3. Pioneer 10 and 11 radio occultations by Jupiter. [atmospheric temperature structure

    NASA Technical Reports Server (NTRS)

    Kliore, A. J.; Woiceshyn, P. M.; Hubbard, W. B.

    1977-01-01

    Results on the temperature structure of the Jovian atmosphere are reviewed which were obtained by applying an integral inversion technique combined with a model for the planet's shape based on gravity data to Pioneer 10 and 11 radio-occultation data. The technique applied to obtain temperature profiles from the Pioneer data consisted of defining a center of refraction based on a computation of the radius of curvature in the plane of refraction and the normal direction to the equipotential surface at the closest approach point of a ray. Observations performed during the Pioneer 10 entry and exit and the Pioneer 11 exit are analyzed, sources of uncertainty are identified, and representative pressure-temperature profiles are presented which clearly show a temperature inversion between 10 and 100 mb. Effects of zonal winds on the reliability of radio-occultation temperature profiles are briefly discussed.

  4. An ionospheric occultation inversion technique based on epoch difference

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Xiong, Jing; Zhu, Fuying; Yang, Jian; Qiao, Xuejun

    2013-09-01

    Of the ionospheric radio occultation (IRO) electron density profile (EDP) retrievals, the Abel based calibrated TEC inversion (CTI) is the most widely used technique. In order to eliminate the contribution from the altitude above the RO satellite, it is necessary to utilize the calibrated TEC to retrieve the EDP, which introduces the error due to the coplanar assumption. In this paper, a new technique based on the epoch difference inversion (EDI) is firstly proposed to eliminate this error. The comparisons between CTI and EDI have been done, taking advantage of the simulated and real COSMIC data. The following conclusions can be drawn: the EDI technique can successfully retrieve the EDPs without non-occultation side measurements and shows better performance than the CTI method, especially for lower orbit mission; no matter which technique is used, the inversion results at the higher altitudes are better than those at the lower altitudes, which could be explained theoretically.

  5. The influence of NO and ClO variations at twilight on the interpretation of solar occultation measurements

    NASA Technical Reports Server (NTRS)

    Boughner, R.; Larsen, J. C.; Natarajan, M.

    1980-01-01

    Measurement of short-lived photochemically-produced species in the stratosphere by solar occultation is difficult because the rapid variation of such species near the terminator introduces ambiguities in interpreting the measured absorption in terms of meaningful atmospheric abundances. These variations produce tangent path concentrations that are asymmetric relative to the tangent point, as opposed to the symmetrical distribution usually assumed in most inversion algorithms. Neglect of this asymmetry may yield an inverted profile that deviates significantly from the true sunset/sunrise profile. In the present paper, the influence of this effect on solar occultation measurements of ClO and NO is examined. The results show that average inhomogeneity factors, which measure the concentration variation along the tangent path and which can be calculated from a photochemical model, can indicate which species require more careful data analysis.

  6. Saturn Conference, Tucson, AZ, May 11-15, 1982, Proceedings

    NASA Astrophysics Data System (ADS)

    1983-05-01

    Topics on Saturn are discussed. The subjects addressed include: the microwave opacity at wavelengths of 3.6 and 13 cm and the particle size distributions in Saturn's rings from Voyager 1 radio occultations; W-shaped occultation signatures and an inference of entwined particle orbits in charged planetary ringlets; the evolution of spokes in Saturn's B ring; the ballistic transport process in collisional interactions of ring particles; and the formation of fine dust on Saturn's rings as suggested by the presence of spokes. Also considered are: Saturn's electrostatic discharges and lightning as their possible cause; thin-layer configurations for the zonal flow; the composition of the Saturnian stratosphere as determined with the IUE; optical properties of Saturn's atmosphere; internal gravity waves in Titan's atmosphere observed by Voyager radio occultation; Hyperion and the collisional disruption of a resonant satellite. For individual items see A83-35727 to A83-35739

  7. THE TAOS PROJECT: RESULTS FROM SEVEN YEARS OF SURVEY DATA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Z.-W.; Lehner, M. J.; Wang, J.-H.

    2013-07-01

    The Taiwanese-American Occultation Survey (TAOS) aims to detect serendipitous occultations of stars by small ({approx}1 km diameter) objects in the Kuiper Belt and beyond. Such events are very rare (<10{sup -3} events per star per year) and short in duration ({approx}200 ms), so many stars must be monitored at a high readout cadence. TAOS monitors typically {approx}500 stars simultaneously at a 5 Hz readout cadence with four telescopes located at Lulin Observatory in central Taiwan. In this paper, we report the results of the search for small Kuiper Belt objects (KBOs) in seven years of data. No occultation events weremore » found, resulting in a 95% c.l. upper limit on the slope of the faint end of the KBO size distribution of q = 3.34-3.82, depending on the surface density at the break in the size distribution at a diameter of about 90 km.« less

  8. Radioimmune localization of occult carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duda, R.B.; Zimmer, A.M.; Rosen, S.T.

    1990-07-01

    Patients with a rising serum carcinoembryonic antigen level and no clinical or roentgenographic evidence of recurrent or metastatic cancer present a treatment dilemma. Eleven such patients, 10 with a previously treated colorectal carcinoma and 1 with a previously treated breast carcinoma, received an injection of the anticarcinoembryonic antigen monoclonal antibody ZCE-025 labeled with the radioisotope indium 111. Nuclear scintigraphy was performed on days 3 and 5 through 7 to detect potential sites of tumor recurrence. The monoclonal antibody scan accurately predicted the presence or absence of occult malignancy in 7 (64%) patients. Second-look laparotomy confirmed the monoclonal antibody scan resultsmore » in the patients with colorectal cancer, and magnetic resonance imaging confirmed metastatic breast cancer. This study demonstrates that In-ZCE-025 can localize occult carcinoma and may assist the surgeon in facilitating the operative exploration. In-ZCE-025 assisted in the initiation of adjuvant therapy for the patient with breast cancer.« less

  9. An overview of occult hepatitis B virus infection

    PubMed Central

    Said, Zeinab Nabil Ahmed

    2011-01-01

    Occult hepatitis B virus (HBV) infection (OBI), alternatively defined as occult hepatitis B (OHB), is a challenging clinical entity. It is recognized by two main characteristics: absence of HBsAg, and low viral replication. The previous two decades have witnessed a remarkable progress in our understanding of OBI and its clinical implications. Appropriate diagnostic techniques must be adopted. Sensitive HBV DNA amplification assay is the gold standard assay for detection of OBI. Viral as well as host factors are implicated in the pathogenesis of OBI. However, published data reporting the infectivity of OBI by transfusion are limited. Several aspects including OBI transmission, infectivity and its relation to the development of chronic liver diseases and hepatocellular carcinoma have to be resolved. The aim of the present review is to highlight recent data on OBI with a focus on its virological diagnosis and clinical outcome. PMID:21528070

  10. No difference in sensitivity for occult infection between tropolone- and oxine-labeled indium-111 leukocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Datz, F.L.; Bedont, R.A.; Baker, W.J.

    1985-05-01

    There is considerable disagreement as to whether oxine or tropolone is the best labeling agent for indium leukocytes. The authors have previously looked at the sensitivity of oxine-labeled /sup 111/In leukocyte scans for occult infections and now present a similar group of patients imaged with tropolone-labeled /sup 111/In leukocytes. Thirty-four patients (38 studies) with possible occult infection were prospectively studied. Patients were imaged 1-4 hr after injection and again at 24 hr postinjection. The differences in sensitivity between oxine and tropolone when imaged early and at 24 hr were not statistically significant. They conclude that there is not significant differencemore » in the ability to detect infection between oxine- and tropolone-labeled leukocytes, both early at 1-4 hr, and on delayed imaging 24 hr after injection.« less

  11. Digital solar edge tracker for the Halogen Occultation Experiment

    NASA Technical Reports Server (NTRS)

    Mauldin, L. E., III; Moore, A. S.; Stump, C. W.; Mayo, L. S.

    1987-01-01

    The optical and electronic design of the Halogen Occultation Experiment (Haloe) elevation sun sensor is described. The Haloe instrument is a gas-correlation radiometer now being developed at NASA Langley for the Upper Atmosphere Research Satellite. The system uses a Galilean telescope to form a solar image on a linear silicon photodiode array. The array is a self-scanned monolithic CCD. The addresses of both solar edges imaged on the array are used by the control/pointing system to scan the Haloe science instantaneous field of view (IFOV) across the vertical solar diameter during instrument calibration and then to maintain the science IFOV 4 arcmin below the top edge during the science data occultation event. Vertical resolution of 16 arcsec and a radiometric dynamic range of 100 are achieved at the 700-nm operating wavelength. The design provides for loss of individual photodiode elements without loss of angular tracking capability.

  12. Lunar occultation of Saturn. II - The normal reflectance of Rhea, Titan, and Iapetus

    NASA Technical Reports Server (NTRS)

    Elliot, J. L.; Dunham, E. W.; Veverka, J.; Goguen, J.

    1978-01-01

    An inversion procedure to obtain the reflectance of the central region of a satellite's disk from lunar occultation data is presented. The scheme assumes that the limb darkening of the satellite depends only on the radial distance from the center of the disk. Given this assumption, normal reflectances can be derived that are essentially independent of the limb darkening and the diameter of the satellite. The procedure has been applied to our observations of the March 1974 lunar occultation of Tethys, Dione, Rhea, Titan, and Iapetus. In the V passband we derive the following normal reflectances: Rhea (0.97 plus or minus 0.20), Titan (0.24 plus or minus 0.03), Iapetus, bright face (0.60 plus or minus 0.14). For Tethys and Dione the values derived have large uncertainties, but are consistent with our result for Rhea.

  13. Are you afraid of the dark? Notes on the psychology of belief in histories of science and the occult.

    PubMed

    Sommer, Andreas

    2016-04-02

    The popular view of the inherent conflict between science and the occult has been rendered obsolete by recent advances in the history of science. Yet, these historiographical revisions have gone unnoticed in the public understanding of science and public education at large. Particularly, reconstructions of the formation of modern psychology and its links to psychical research can show that the standard view of the latter as motivated by metaphysical bias fails to stand up to scrutiny. After highlighting certain basic methodological maxims shared by psychotherapists and historians, I will try to counterbalance simplistic claims of a 'need to believe' as a precondition of scientific open-mindedness regarding the occurrence of parapsychological phenomena by discussing instances revealing a presumably widespread 'will to disbelieve' in the occult. I shall argue that generalized psychological explanations are only helpful in our understanding of history if we apply them in a symmetrical manner.

  14. Advancing Technology for Starlight Suppression via an External Occulter

    NASA Technical Reports Server (NTRS)

    Kasdin, N. J.; Spergel, D. N.; Vanderbei, R. J.; Lisman, D.; Shaklan, S.; Thomson, M.; Walkemeyer, P.; Bach, V.; Oakes, E.; Cady, E.; hide

    2011-01-01

    External occulters provide the starlight suppression needed for detecting and characterizing exoplanets with a much simpler telescope and instrument than is required for the equivalent performing coronagraph. In this paper we describe progress on our Technology Development for Exoplanet Missions project to design, manufacture, and measure a prototype occulter petal. We focus on the key requirement of manufacturing a precision petal while controlling its shape within precise tolerances. The required tolerances are established by modeling the effect that various mechanical and thermal errors have on scatter in the telescope image plane and by suballocating the allowable contrast degradation between these error sources. We discuss the deployable starshade design, representative error budget, thermal analysis, and prototype manufacturing. We also present our meteorology system and methodology for verifying that the petal shape meets the contrast requirement. Finally, we summarize the progress to date building the prototype petal.

  15. Recovery of refractivity profiles and pressure and temperature distributions in the lower atmosphere from satellite-to-satellite radio occultation data

    NASA Technical Reports Server (NTRS)

    Murray, C. W., Jr.

    1977-01-01

    The feasibility of recovering parameters from one-way range rate between two earth orbiting spacecraft during occultation of the tracking signal by the earth's lower atmosphere. The tracking data is inverted by an integral transformation (Abel transform) to obtain a vertical refractivity profile above the point of closest approach of the ray connecting the satellites. Pressure and temperature distributions can be obtained from values of dry refractivity using the hydrostatic equation and perfect gas law. Two methods are investigated for recovering pressure and temperature parameters. Results show that recovery is much more sensitive to satellite velocity errors than to satellite position errors. An error analysis is performed. An example is given demonstrating recovery of parameters from radio occultation data obtained during satellite-to-satellite tracking of Nimbus 6 by the ATS 6 satellite.

  16. Titania's radius and an upper limit on its atmosphere from the September 8, 2001 stellar occultation

    NASA Astrophysics Data System (ADS)

    Widemann, T.; Sicardy, B.; Dusser, R.; Martinez, C.; Beisker, W.; Bredner, E.; Dunham, D.; Maley, P.; Lellouch, E.; Arlot, J.-E.; Berthier, J.; Colas, F.; Hubbard, W. B.; Hill, R.; Lecacheux, J.; Lecampion, J.-F.; Pau, S.; Rapaport, M.; Roques, F.; Thuillot, W.; Hills, C. R.; Elliott, A. J.; Miles, R.; Platt, T.; Cremaschini, C.; Dubreuil, P.; Cavadore, C.; Demeautis, C.; Henriquet, P.; Labrevoir, O.; Rau, G.; Coliac, J.-F.; Piraux, J.; Marlot, Ch.; Marlot, C.; Gorry, F.; Sire, C.; Bayle, B.; Simian, E.; Blommers, A. M.; Fulgence, J.; Leyrat, C.; Sauzeaud, C.; Stephanus, B.; Rafaelli, T.; Buil, C.; Delmas, R.; Desnoux, V.; Jasinski, C.; Klotz, A.; Marchais, D.; Rieugnié, M.; Bouderand, G.; Cazard, J.-P.; Lambin, C.; Pujat, P.-O.; Schwartz, F.; Burlot, P.; Langlais, P.; Rivaud, S.; Brochard, E.; Dupouy, Ph.; Lavayssière, M.; Chaptal, O.; Daiffallah, K.; Clarasso-Llauger, C.; Aloy Doménech, J.; Gabaldá-Sánchez, M.; Otazu-Porter, X.; Fernández, D.; Masana, E.; Ardanuy, A.; Casas, R.; Ros, J. A.; Casarramona, F.; Schnabel, C.; Roca, A.; Labordena, C.; Canales-Moreno, O.; Ferrer, V.; Rivas, L.; Ortiz, J. L.; Fernández-Arozena, J.; Martín-Rodríguez, L. L.; Cidadão, A.; Coelho, P.; Figuereido, P.; Gonçalves, R.; Marciano, C.; Nunes, R.; Ré, P.; Saraiva, C.; Tonel, F.; Clérigo, J.; Oliveira, C.; Reis, C.; Ewen-Smith, B. M.; Ward, S.; Ford, D.; Gonçalves, J.; Porto, J.; Laurindo Sobrinho, J.; Teodoro de Gois, F.; Joaquim, M.; Afonso da Silva Mendes, J.; van Ballegoij, E.; Jones, R.; Callender, H.; Sutherland, W.; Bumgarner, S.; Imbert, M.; Mitchell, B.; Lockhart, J.; Barrow, W.; Cornwall, D.; Arnal, A.; Eleizalde, G.; Valencia, A.; Ladino, V.; Lizardo, T.; Guillén, C.; Sánchez, G.; Peña, A.; Radaelli, S.; Santiago, J.; Vieira, K.; Mendt, H.; Rosenzweig, P.; Naranjo, O.; Contreras, O.; Díaz, F.; Guzmán, E.; Moreno, F.; Omar Porras, L.; Recalde, E.; Mascaró, M.; Birnbaum, C.; Cósias, R.; López, E.; Pallo, E.; Percz, R.; Pulupa, D.; Simbaña, X.; Yajamín, A.; Rodas, P.; Denzau, H.; Kretlow, M.; Valdés Sada, P.; Hernández, R.; Hernández, A.; Wilson, B.; Castro, E.; Winkel, J. M.

    2009-02-01

    On September 8, 2001 around 2 h UT, the largest uranian moon, Titania, occulted Hipparcos star 106829 (alias SAO 164538, a V=7.2, K0 III star). This was the first-ever observed occultation by this satellite, a rare event as Titania subtends only 0.11 arcsec on the sky. The star's unusual brightness allowed many observers, both amateurs or professionals, to monitor this unique event, providing fifty-seven occultations chords over three continents, all reported here. Selecting the best 27 occultation chords, and assuming a circular limb, we derive Titania's radius: R=788.4±0.6km ( 1-σ error bar). This implies a density of ρ=1.711±0.005gcm using the value GM=(2.343±0.006)×10ms derived by Taylor [Taylor, D.B., 1998. Astron. Astrophys. 330, 362-374]. We do not detect any significant difference between equatorial and polar radii, in the limit r-r=-1.3±2.1km, in agreement with Voyager limb image retrieval during the 1986 flyby. Titania's offset with respect to the DE405 + URA027 (based on GUST86 theory) ephemeris is derived: Δαcos(δ)=-108±13 mas and Δδ=-62±7 mas (ICRF J2000.0 system). Most of this offset is attributable to a Uranus' barycentric offset with respect to DE405, that we estimate to be: Δαcos(δ)=-100±25mas and Δδ=-85±25 mas at the moment of occultation. This offset is confirmed by another Titania stellar occultation observed on August 1st, 2003, which provides an offset of Δαcos(δ)=-127±20 mas and Δδ=-97±13 mas for the satellite. The combined ingress and egress data do not show any significant hint for atmospheric refraction, allowing us to set surface pressure limits at the level of 10-20 nbar. More specifically, we find an upper limit of 13 nbar ( 1-σ level) at 70 K and 17 nbar at 80 K, for a putative isothermal CO 2 atmosphere. We also provide an upper limit of 8 nbar for a possible CH 4 atmosphere, and 22 nbar for pure N 2, again at the 1-σ level. We finally constrain the stellar size using the time-resolved star disappearance and reappearance at ingress and egress. We find an angular diameter of 0.54±0.03 mas (corresponding to 7.5±0.4km projected at Titania). With a distance of 170±25 parsecs, this corresponds to a radius of 9.8±0.2 solar radii for HIP 106829, typical of a K0 III giant.

  17. Observations with the GISMOS Airborne Radio Occultation System

    NASA Astrophysics Data System (ADS)

    Muradyan, Paytsar; Haase, Jennifer; Garrison, James; Lulich, Tyler; Xie, Feiqin

    2010-05-01

    The spatial sample density of temperature and moisture profiles derived from the current spaceborne GPS radio occultation (RO) constellation is limited by the number of occultation satellites in operation. With the current RO satellite configuration, only one RO profile per day is typically available in a 160,000 square kilometer area in the mid-latitude and tropics and slightly more in high latitudes. The airborne RO technique, which has the GPS receiver onboard an airplane, offers flexibility and much denser sampling for targeted observation within 400 km of the aircraft, and provides comparable high vertical resolution to that of the spaceborne case. With an airborne system, targeted measurements can be planned in an optimal geometry to study the accuracy of RO measurements in the lower troposphere where strong vertical gradients in moisture might lead to disruption of signal tracking. These dense measurements can also be used to test assimilation techniques of refractivity and lower tropospheric moisture derived from RO data. In February 2008, the GNSS Instrument System for Multistatic and Occultation Sensing (GISMOS), developed at Purdue University, was successfully deployed on the NSF HIAPER aircraft for series of research flights in the Gulf of Mexico coastal region to validate the airborne observing system. During this campaign, occultation observations were collected in conjunction with supplemental radiosonde and dropsonde soundings. RO signals were recorded using side-looking GPS antennas and dual frequency GPS receivers. However, these conventional phase-locked-loop GPS receivers cannot always track the signal in the lower troposphere, where there are rapid phase accelerations caused by highly variable moisture structures. To extend the observations deeper into the atmosphere, the raw signal from occulting satellites is recorded at 10MHz sampling interval by a GPS recording system (GRS). Open-loop (OL) tracking, which replaces the traditional GPS receiver feedback loop using an a priori estimate of Doppler frequency, was implemented in a software receiver and the data was post-processed after the flight. Such an extensive dataset can be of importance in studies aimed at improving signal processing performance for spaceborne as well as airborne RO measurements. We present data from the February 2008 campaign, and show several examples of occultations with clear atmospheric signals in the excess phase and Doppler. Many recordings that were made with conventional receivers descend below 5 km in the atmosphere. With an OL tracking procedure using the data recorded by the GRS, the measurements extended deeper into the atmosphere (~ 2km above surface). Raytracing was used to simulate the atmospheric excess phase profile from a nearby radiosonde sounding. The excess phase profiles acquired with both closed-loop and open-loop tracking show consistent patterns compared to the radiosonde observations.

  18. Particle sizes in Saturn's rings from UVIS stellar occultations 1. Variations with ring region

    NASA Astrophysics Data System (ADS)

    Colwell, J. E.; Esposito, L. W.; Cooney, J. H.

    2018-01-01

    The Cassini spacecraft's Ultraviolet Imaging Spectrograph (UVIS) includes a high speed photometer (HSP) that has observed stellar occultations by Saturn's rings with a radial resolution of ∼10 m. In the absence of intervening ring material, the time series of measurements by the HSP is described by Poisson statistics in which the variance equals the mean. The finite sizes of the ring particles occulting the star lead to a variance that is larger than the mean due to correlations in the blocking of photons due to finite particle size and due to random variations in the number of individual particles in each measurement area. This effect was first exploited by Showalter and Nicholson (1990) with the stellar occultation observed by Voyager 2. At a given optical depth, a larger excess variance corresponds to larger particles or clumps that results in greater variation of the signal from measurement to measurement. Here we present analysis of the excess variance in occultations observed by Cassini UVIS. We observe differences in the best-fitting particle size in different ring regions. The C ring plateaus show a distinctly smaller effective particle size, R, than the background C ring, while the background C ring itself shows a positive correlation between R and optical depth. The innermost 700 km of the B ring has a distribution of excess variance with optical depth that is consistent with the C ring ramp and C ring but not with the remainder of the B1 region. The Cassini Division, while similar to the C ring in spectral and structural properties, has different trends in effective particle size with optical depth. There are discrete jumps in R on either side of the Cassini Division ramp, while the C ring ramp shows a smooth transition in R from the C ring to the B ring. The A ring is dominated by self-gravity wakes whose shadow size depends on the occultation geometry. The spectral ;halo; regions around the strongest density waves in the A ring correspond to decreases in R. There is also a pronounced dip in R at the Mimas 5:3 bending wave corresponding to an increase in optical depth there, suggesting that at these waves small particles are liberated from clumps or self-gravity wakes leading to a reduction in effective particle size and an increase in optical depth.

  19. Atmospheric gravity wave detection following the 2011 Tohoku earthquakes combining COSMIC occultation and GPS observations

    NASA Astrophysics Data System (ADS)

    Yan, X.; Tao, Y.; Xia, C.; Qi, Y.; Zuo, X.

    2017-12-01

    Several studies have reported the earthquake-induced atmospheric gravity waves detected by some new technologies such as airglow (Makela et al., 2011), GOCE (Garcia et al., 2013), GRACE (Yang et al., 2014), F3/C radio occultation sounding (Coïsson et al., 2015). In this work, we collected all occultation events on 11 March, and selected four events to analyze at last. The original and filtered podTEC is represented as function of the altitude of the impact parameter and UT of the four events. Then, the travel time diagrams of filtered podTEC derived from the events were analyzed. The occultation signal from one event (marked as No.73) is consistent with the previous results reported by Coïsson. 2015, which is corresponds to the ionospheric signal induced from tsunami gravity wave. What is noticeable, in this work, is that three occultation events of No.403, 77 and 118 revealed a disturbance of atmospheric gravity wave with velocity 300m/s, preceding the tsunami. It would probably be correspond to the gravity waves caused by seismic rupture but not tsunami. In addition, it can be seen that the perturbation height of occultation observation TEC is concentrated at 200-400km, corresponding ionosphere F region. The signals detected above are compared with GPS measurements of TEC from GEONET and IGS. From GPS data, traveling ionospheric disturbances were observed spreading out from the epicenter as a quasi-circular propagation pattern with the time. Exactly, we observed an acoustic wave coupled with Rayleigh wave starting from the epicenter with a speed of 3.0km/s and a superimposed acoustic-gravity wave moving with a speed of 800m/s. The acoustic-gravity wave generated at the epicenter and gradually attenuated 800km away, then it is replaced by a gravity wave coupled with the tsunami that moves with a speed of between 100 and 300m/s. It is necessary to confirm the propagation process of the waves if we attempt to evaluate the use of ionospheric seismology as a potential support for future earthquake and tsunami warning systems. Acknowledgement: This work is supported by NSFC (41604135), China Postdoctoral Science Foundation funded project (1231703), State Key Laboratory of Earthquake Dynamics (LED2015B04), Key Laboratory of Earth and Planetary Physics, Hubei Subsurface Multi-scale Imaging Key Laboratory.

  20. Enceladus' Supersonic Gas Jets' Role in Diurnal Variability of Particle Flux

    NASA Astrophysics Data System (ADS)

    Hansen, Candice; Esposito, Larry W.; Portyankina, Ganna; Hendrix, Amanda; Colwell, Joshua E.; Aye, Klaus-Michael

    2016-10-01

    Introduction: The Cassini Ultraviolet Imaging Spectrograph (UVIS) has observed 6 occultations of stars by Enceladus' plume from 2005 to 2011 [1]. Supersonic gas jets were detected, imbedded in the overall expulsion of gas at escape velocity along the tiger stripe fissures that cross Enceladus' south pole [2]. The gas flux can be calculated [1], and is observed to vary just 15% in over 6 years, representing a steady output of ~200 kg/sec. In contrast, the brightness of the particle jets, a proxy for the amount of particles expelled, varies 3x with orbital longitude [3], implicating tidal stresses. This is not necessarily inconsistent with the steady gas flux, which had not been measured at apokrone until now.2016 epsilon Orionis Occultation: In order to investigate whether gas flow increases dramatically at apokrone an occultation observation was inserted into the Cassini tour on March 11, 2016 on orbit 233. Enceladus was at a mean anomaly of 208 at the time of the occultation. Using the same methodology as previously employed the column density has been determined to be 1.5 x 1016 cm-2, giving a gas flux of 250 kg/sec. This value is 20% higher than the average 210 kg/sec, but only 15% higher than the occultations at a mean anomaly of 236; i.e. higher than the others but not by a factor of 2 or 3. The overall expulsion of gas from the south pole of Enceladus thus does not seem to change dramatically with orbital position.Jets: The line of sight to the star pierced the Baghdad I gas jet. The jet data, in contrast to the integrated plume, look significantly different in this dataset. The column density of the jet is higher than observed in previous occultations. The collimation of the jet is more pronounced and from that we derive a mach number of 8-9, compared to a previous value for this jet of 6. We conclude that the higher velocity and increased quantity of gas in the jet close to apokrone indicate that the jets are the primary contributors to the increased particle flux observed at apokrone.References: [1] Hansen, C. J. et al. (2006) Science, 311, 1422-1425. [2] Hansen, C. J. et al. (2008) Nature, 456, 477-479. [3] Hedman, M. M. et al. (2013) Nature, 500, 182-184

Top