Sample records for ocular irritation potential

  1. The EpiOcular™ Eye Irritation Test is the Method of Choice for the In Vitro Eye Irritation Testing of Agrochemical Formulations: Correlation Analysis of EpiOcular Eye Irritation Test and BCOP Test Data According to the UN GHS, US EPA and Brazil ANVISA Classification Schemes.

    PubMed

    Kolle, Susanne N; Rey Moreno, Maria Cecilia; Mayer, Winfried; van Cott, Andrew; van Ravenzwaay, Bennard; Landsiedel, Robert

    2015-07-01

    The Bovine Corneal Opacity and Permeability (BCOP) test is commonly used for the identification of severe ocular irritants (GHS Category 1), but it is not recommended for the identification of ocular irritants (GHS Category 2). The incorporation of human reconstructed tissue model-based tests into a tiered test strategy to identify ocular non-irritants and replace the Draize rabbit eye irritation test has been suggested (OECD TG 405). The value of the EpiOcular™ Eye Irritation Test (EIT) for the prediction of ocular non-irritants (GHS No Category) has been demonstrated, and an OECD Test Guideline (TG) was drafted in 2014. The purpose of this study was to evaluate whether the BCOP test, in conjunction with corneal histopathology (as suggested for the evaluation of the depth of the injury( and/or the EpiOcular-EIT, could be used to predict the eye irritation potential of agrochemical formulations according to the UN GHS, US EPA and Brazil ANVISA classification schemes. We have assessed opacity, permeability and histopathology in the BCOP assay, and relative tissue viability in the EpiOcular-EIT, for 97 agrochemical formulations with available in vivo eye irritation data. By using the OECD TG 437 protocol for liquids, the BCOP test did not result in sufficient correct predictions of severe ocular irritants for any of the three classification schemes. The lack of sensitivity could be improved somewhat by the inclusion of corneal histopathology, but the relative viability in the EpiOcular-EIT clearly outperformed the BCOP test for all three classification schemes. The predictive capacity of the EpiOcular-EIT for ocular non-irritants (UN GHS No Category) for the 97 agrochemical formulations tested (91% sensitivity, 72% specificity and 82% accuracy for UN GHS classification) was comparable to that obtained in the formal validation exercise underlying the OECD draft TG. We therefore conclude that the EpiOcular-EIT is currently the best in vitro method for the prediction of the eye irritation potential of liquid agrochemical formulations. 2015 FRAME.

  2. Evaluation of Ocular Irritation and Bioavailability of Voriconazole Loaded Microemulsion.

    PubMed

    Kumar, Rakesh; Sinha, Vivek Ranjan

    2017-01-01

    Voriconazole (VCZ), a second-generation antifungal with excellent attributes like, broad-spectrum activity, targeted delivery, and tolerability. VCZ loaded microemulsion could be an effective strategy for efficient ocular delivery of the drug. To perform corneal irritation studies and in vivo delivery of VCZ microemulsion to establish its potential as an efficient ocular delivery system. Ocular irritancy was performed by HETCAM (Hen's Egg Test Chorio Allantoic Membrane) assay, corneal histopathology and Draize test. Ex vivo and in vivo studies were performed to determine permeation efficiency of VCZ microemulsion. The irritation studies suggested the non-irritant nature of the microemulsion. The ex vivo studies performed on excised cornea displayed significant enhancement in drug permeation/penetration from microemulsion in contrast to the drug suspension. Further, the in vivo study confirmed the higher availability of VCZ (from microemulsion) in aqueous humor with minimal nasolacrimal drainage (lower plasma drug content) when compared with the drug suspension. The non-irritant nature and high corneal permeation of VCZ encourages the role of microemulsion as a potential ocular delivery system. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Survey of ocular irritation predictive capacity using Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test historical data for 319 personal care products over fourteen years.

    PubMed

    Donahue, D A; Kaufman, L E; Avalos, J; Simion, F A; Cerven, D R

    2011-03-01

    The Chorioallantoic Membrane Vascular Assay (CAMVA) and Bovine Corneal Opacity and Permeability (BCOP) test are widely used to predict ocular irritation potential for consumer-use products. These in vitro assays do not require live animals, produce reliable predictive data for defined applicability domains compared to the Draize rabbit eye test, and are rapid and inexpensive. Data from 304 CAMVA and/or BCOP studies (319 formulations) were surveyed to determine the feasibility of predicting ocular irritation potential for various formulations. Hair shampoos, skin cleansers, and ethanol-based hair styling sprays were repeatedly predicted to be ocular irritants (accuracy rate=0.90-1.00), with skin cleanser and hair shampoo irritation largely dependent on surfactant species and concentration. Conversely, skin lotions/moisturizers and hair styling gels/lotions were repeatedly predicted to be non-irritants (accuracy rate=0.92 and 0.82, respectively). For hair shampoos, ethanol-based hair stylers, skin cleansers, and skin lotions/moisturizers, future ocular irritation testing (i.e., CAMVA/BCOP) can be nearly eliminated if new formulations are systematically compared to those previously tested using a defined decision tree. For other tested product categories, new formulations should continue to be evaluated in CAMVA/BCOP for ocular irritation potential because either the historical data exhibit significant variability (hair conditioners and mousses) or the historical sample size is too small to permit definitive conclusions (deodorants, make-up removers, massage oils, facial masks, body sprays, and other hair styling products). All decision tree conclusions should be made within a conservative weight-of-evidence context, considering the reported limitations of the BCOP test for alcohols, ketones, and solids. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Development of the EpiOcular(TM) eye irritation test for hazard identification and labelling of eye irritating chemicals in response to the requirements of the EU cosmetics directive and REACH legislation.

    PubMed

    Kaluzhny, Yulia; Kandárová, Helena; Hayden, Patrick; Kubilus, Joseph; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2011-09-01

    The recently implemented 7th Amendment to the EU Cosmetics Directive and the EU REACH legislation have heightened the need for in vitro ocular test methods. To address this need, the EpiOcular(TM) eye irritation test (EpiOcular-EIT), which utilises the normal (non-transformed) human cell-based EpiOcular tissue model, has been developed. The EpiOcular-EIT prediction model is based on an initial training set of 39 liquid and 21 solid test substances and uses a single exposure period and a single cut-off in tissue viability, as determined by the MTT assay. A chemical is classified as an irritant (GHS Category 1 or 2), if the tissue viability is ≤ 60%, and as a non-irritant (GHS unclassified), if the viability is > 60%. EpiOcular-EIT results for the training set, along with results for an additional 52 substances, which included a range of alcohols, hydrocarbons, amines, esters, and ketones, discriminated between ocular irritants and non-irritants with 98.1% sensitivity, 72.9% specificity, and 84.8% accuracy. To ensure the long-term commercial viability of the assay, EpiOcular tissues produced by using three alternative cell culture inserts were evaluated in the EpiOcular-EIT with 94 chemicals. The assay results obtained with the initial insert and the three alternative inserts were very similar, as judged by correlation coefficients (r²) that ranged from 0.82 to 0.96. The EpiOcular-EIT was pre-validated in 2007/2008, and is currently involved in a formal, multi-laboratory validation study sponsored by the European Cosmetics Association (COLIPA) under the auspices of the European Centre for the Validation of Alternative Methods (ECVAM). The EpiOcular-EIT, together with EpiOcular's long history of reproducibility and proven utility for ultra-mildness testing, make EpiOcular a useful model for addressing current legislation related to animal use in the testing of potential ocular irritants. 2011 FRAME.

  5. Evaluation of ocular irritancy of coal-tar dyes used in cosmetics employing reconstructed human cornea-like epithelium and short time exposure tests.

    PubMed

    Lee, Miri; Nam, Ki Taek; Kim, Jungah; Lim, Song E; Yeon, Sang Hyeon; Lee, Buhyun; Lee, Joo Young; Lim, Kyung-Min

    2017-10-01

    Coal-tar dyes in cosmetics may elicit adverse effects in the skin and eyes. Countries, like the US, have banned the use of coal-tar dyes in cosmetics for the eye area due to the potential for ocular irritation. We evaluated the eye irritation potential of 15 coal-tar dyes permitted as cosmetic ingredients in reconstructed human cornea-like epithelium (RhCEs [EpiOcular™ and MCTT HCE™]) tests and the short time exposure (STE) test. Eosin YS, phloxine B, tetrachlorotetrabromofluorescein, and tetrabromofluorescein were identified as irritants in RhCEs; dibromofluorescein and uranine yielded discrepant results. STE enabled further classification in accordance with the UN Globally Harmonized System of Classification and Labelling of Chemicals, as follows: eosin YS as Cat 2; phloxine B, Cat 1; and tetrachlorotetrabromofluorescein and tetrabromofluorescein, Cat 1/2. STE indicated dibromofluorescein (irritant in EpiOcular™) and uranine (irritant in MCTT HCE™) as No Cat, resulting in the classification of "No prediction can be made." based on bottom-up approach with each model. These results demonstrated that in vitro eye irritation tests can be utilized to evaluate the potential ocular irritancy of cosmetic ingredients and provide significant evidence with which to determine whether precautions should be given for the use of coal-tar dyes in cosmetics or other substances applied to the eye area. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Evaluation of seven in vitro alternatives for ocular safety testing.

    PubMed

    Bruner, L H; Kain, D J; Roberts, D A; Parker, R D

    1991-07-01

    Seven in vitro assays were evaluated to determine if any were useful as screening procedures in ocular safety assessment. Seventeen test materials (chemicals, household cleaners, hand soaps, dishwashing liquids, shampoos, and liquid laundry detergents) were tested in each assay. In vivo ocular irritation scores for the materials were obtained from existing rabbit low volume eye test (LVET) data. The seven assays evaluated included the silicon microphysiometer (SM), luminescent bacteria toxicity test (LBT), neutral red assay (NR), total protein assay (TP), Tetrahymena thermophila motility assay (TTMA), bovine eye/chorioallantoic membrane assay (BE/CAM), and the EYTEX system (ETS). For the seventeen materials used in this study there was a significant correlation between the in vivo irritant potential and in vitro data for all the tests except the EYTEX System (SM, r = -0.87; LBT, r = -0.91; NR, r = -0.85; TTMA, r = 0.78; TP, r = -0.86; ETS, r = 0.29). The irritation classifications provided by the BE/CAM also did not correspond with the actual in vivo irritancy potential of the test materials. The result of this study suggested it may be possible to classify materials into broad irritancy categories with some of the assays. This would allow their use as screens prior to limited in vivo confirmation in the ocular safety assessment process.

  7. Evaluation of Trigeminal Sensitivity to Ammonia in Asthmatics and Healthy Human Volunteers

    PubMed Central

    Petrova, Maja; Diamond, Jeanmarie; Schuster, Benno; Dalton, Pamela

    2009-01-01

    Background Asthmatics often report the triggering or exacerbation of respiratory symptoms following exposure to airborne irritants, which in some cases may result from stimulation of irritant receptors in the upper airways inducing reflexive broncho-constriction. Ammonia (NH3) is a common constituent of commercially available household products, and in high concentration has the potential to elicit sensory irritation in the eyes and upper respiratory tract of humans. The goal of the present study was to evaluate the irritation potential of ammonia in asthmatics and healthy volunteers and to determine whether differences in nasal or ocular irritant sensitivity to ammonia between these two groups could account for the exacerbation of symptoms reported by asthmatics following exposure to an irritant. Methods 25 healthy and 15 mild/moderate persistent asthmatic volunteers, with reported sensitivity to household cleaning products, were evaluated for their sensitivity to the ocular and nasal irritancy of NH3. Lung function was evaluated at baseline and multiple time points following exposure. Results Irritation thresholds did not differ between asthmatics and healthy controls, nor did ratings of odor intensity, annoyance and irritancy following exposure to NH3 concentrations at and above the irritant threshold for longer periods of time (30 sec).Importantly, no changes in lung function occurred following exposure to NH3 for any individuals in either group. Conclusion Despite heightened symptom reports to environmental irritants among asthmatics, the ocular and nasal trigeminal system of mild-moderate asthmatics does not appear to be more sensitive or more reactive than that of non-asthmatics, nor does short duration exposure to ammonia at irritant levels induce changes in lung function. At least in brief exposures, the basis for some asthmatics to experience adverse responses to volatile compounds in everyday life may arise from factors other than trigeminally-mediated reflexes. PMID:18728993

  8. Testing ocular irritancy in vitro with the silicon microphysiometer.

    PubMed

    Bruner, L H; Miller, K R; Owicki, J C; Parce, J W; Muir, V C

    1991-01-01

    The silicon microphysiometer, an instrument based on the light-addressable potentiometric sensor, was evaluated as an in vitro alternative for assessing ocular irritancy potential. It indirectly and non-invasively measures cell metabolism by determining the rate of acid metabolite production from cells, in this case human epidermal keratinocytes, placed inside the microphysiometer chamber. The 17 materials used for the evaluation included bar soaps, a liquid hand soap, shampoos, dishwashing liquids, laundry detergents, a fabric softener and several single chemicals. All materials tested were in liquid form. The in vivo irritancy potential of the materials was obtained from historical data using the rabbit low-volume eye test. There was a positive correlation between the in vivo irritancy potential of the test materials and the concentration of test material that decreased the acidification rate of cells by 50% (MRD(50); r = 0.86, P < 0.0001). Preliminary studies suggest other endpoints obtainable from the system may also provide useful information for making ocular safety assessments. Because the method is non-invasive, it is possible to determine whether cells recover from a treatment with the test material. The metabolic rate of the cells also increases at sub-inhibitory concentrations of some of the test materials. Because of the good correlation between the in vivo and in vitro data, the ease with which test materials can be applied to the system, and the multiple endpoints available from the system, it holds great potential as a useful in vitro alternative for ocular safety testing.

  9. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

    PubMed Central

    Jang, Won-hee; Jung, Kyoung-mi; Yang, Hye-ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-01-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCETM which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCETM can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines. PMID:26157556

  10. Ocular toxicity of authentic lunar dust

    PubMed Central

    2012-01-01

    Background Dust exposure is a well-known occupational hazard for terrestrial workers and astronauts alike and will continue to be a concern as humankind pursues exploration and habitation of objects beyond Earth. Humankind’s limited exploration experience with the Apollo Program indicates that exposure to dust will be unavoidable. Therefore, NASA must assess potential toxicity and recommend appropriate mitigation measures to ensure that explorers are adequately protected. Visual acuity is critical during exploration activities and operations aboard spacecraft. Therefore, the present research was performed to ascertain the ocular toxicity of authentic lunar dust. Methods Small (mean particle diameter = 2.9 ± 1.0 μm), reactive lunar dust particles were produced by grinding bulk dust under ultrapure nitrogen conditions. Chemical reactivity and cytotoxicity testing were performed using the commercially available EpiOcularTM assay. Subsequent in vivo Draize testing utilized a larger size fraction of unground lunar dust that is more relevant to ocular exposures (particles <120 μm; median particle diameter = 50.9 ± 19.8 μm). Results In vitro testing indicated minimal irritancy potential based on the time required to reduce cell viability by 50% (ET50). Follow-up testing using the Draize standard protocol confirmed that the lunar dust was minimally irritating. Minor irritation of the upper eyelids was noted at the 1-hour observation point, but these effects resolved within 24 hours. In addition, no corneal scratching was observed using fluorescein stain. Conclusions Low-titanium mare lunar dust is minimally irritating to the eyes and is considered a nuisance dust for ocular exposure. No special precautions are recommended to protect against ocular exposures, but fully shielded goggles may be used if dust becomes a nuisance. PMID:22817808

  11. Ocular toxicity of authentic lunar dust.

    PubMed

    Meyers, Valerie E; Garcìa, Hector D; Monds, Kathryn; Cooper, Bonnie L; James, John T

    2012-07-20

    Dust exposure is a well-known occupational hazard for terrestrial workers and astronauts alike and will continue to be a concern as humankind pursues exploration and habitation of objects beyond Earth. Humankind's limited exploration experience with the Apollo Program indicates that exposure to dust will be unavoidable. Therefore, NASA must assess potential toxicity and recommend appropriate mitigation measures to ensure that explorers are adequately protected. Visual acuity is critical during exploration activities and operations aboard spacecraft. Therefore, the present research was performed to ascertain the ocular toxicity of authentic lunar dust. Small (mean particle diameter = 2.9 ± 1.0 μm), reactive lunar dust particles were produced by grinding bulk dust under ultrapure nitrogen conditions. Chemical reactivity and cytotoxicity testing were performed using the commercially available EpiOcularTM assay. Subsequent in vivo Draize testing utilized a larger size fraction of unground lunar dust that is more relevant to ocular exposures (particles <120 μm; median particle diameter = 50.9 ± 19.8 μm). In vitro testing indicated minimal irritancy potential based on the time required to reduce cell viability by 50% (ET50). Follow-up testing using the Draize standard protocol confirmed that the lunar dust was minimally irritating. Minor irritation of the upper eyelids was noted at the 1-hour observation point, but these effects resolved within 24 hours. In addition, no corneal scratching was observed using fluorescein stain. Low-titanium mare lunar dust is minimally irritating to the eyes and is considered a nuisance dust for ocular exposure. No special precautions are recommended to protect against ocular exposures, but fully shielded goggles may be used if dust becomes a nuisance.

  12. Evaluation of the Ocular Tolerance of Three Tacrolimus Topical Pharmaceutical Preparations by Bovine Corneal Opacity and Permeability Test.

    PubMed

    Pastor-Clerigues, Alfonso; Serrano, Adela; Milara, Javier; Marti-Bonmati, Ezequiel; Lopez-Perez, Francisco J; Garcia-Montanes, Sara; Sanfeliu, Joan; Saval-Victoria, Ana C; Cortijo, Julio

    2016-07-01

    Tacrolimus ocular preparations are commonly employed in autoimmune or inflammatory ocular disorders. However, currently there are not yet approved ocular formulations. Tacrolimus ocular side effects have been reported in clinical use, so the evaluation of different pharmaceutical preparations is mandatory. In this study, the local corneal tolerance and safety profile of three common tacrolimus 0.03% pharmaceutical preparations were evaluated. Corneal irritation and permeability of tacrolimus preparations were evaluated with the bovine corneal opacity and permeability (BCOP) test. Complementary corneal hematoxylin/eosin and immunohistochemistry staining for tight junctions and adherent junctions E-cadherin, VE-cadherin and zonula occludens-1 were examined and scored to evaluate and to confirm corneal disruption and irritation scores obtained with the BCOP method. Commercial brand ointment (Protopic®), topical compounded eye ointment (pharmacy elaboration) and tacrolimus suspension eye drops (elaborated from parenteral prograf®) were tested as potential ocular preparations to be used in clinics. Tacrolimus preparations hereby studied do not alter the opacity and permeability of the bovine cornea by more than three units, measured by the In Vitro Irritancy Score, neither affected the immunohistochemical parameters, composite score or transepithelial electrical resistance. Tacrolimus preparations studied can be safely applied as a topical ocular treatment.

  13. The hen's egg chorioallantoic membrane (HET-CAM) test to predict the ophthalmic irritation potential of a cysteamine-containing gel: Quantification using Photoshop® and ImageJ.

    PubMed

    McKenzie, Barbara; Kay, Graeme; Matthews, Kerr H; Knott, Rachel M; Cairns, Donald

    2015-07-25

    A modified hen's egg chorioallantoic membrane (HET-CAM) test has been developed, combining ImageJ analysis with Adobe(®) Photoshop(®). The irritation potential of an ophthalmic medicine can be quantified using this method, by monitoring damage to blood vessels. The evaluation of cysteamine containing hyaluronate gel is reported. The results demonstrated that the novel gel formulation is non-irritant to the ocular tissues, in line with saline solution (negative control). In conclusion, the modification of the established HET-CAM test can quantify the damage to minute blood vessels. These results offer the possibility to formulate cysteamine in an ocular applicable gel formulation. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Two-stage bottom-up tiered approach combining several alternatives for identification of eye irritation potential of chemicals including insoluble or volatile substances.

    PubMed

    Hayashi, Kazuhiko; Mori, Taeko; Abo, Takayuki; Ooshima, Kenichi; Hayashi, Takumi; Komano, Tomoko; Takahashi, Yutaka; Sakaguchi, Hitoshi; Takatsu, Akihiko; Nishiyama, Naohiro

    2012-10-01

    For the assessment of eye irritation, one alternative test may not completely replace the rabbit Draize test. In the present study, we examined the predictive potential of a tiered approach analyzing the results from several alternatives (i.e., the Short Time Exposure (STE) test, the EpiOcular assay, the Hen's Egg Test-Chorioallantoic Membrane (HET-CAM) assay and the Bovine Corneal Opacity and Permeability (BCOP) assay) for assessing Globally Harmonized System (GHS) eye irritation categories. Fifty-six chemicals including alcohols, surfactants, and esters were selected with a balanced GHS category and a wide range of chemical classes. From a standpoint of both assessable sample numbers and predictive accuracy, the more favorable tiered approach was considered to be the two-stage bottom-up tiered approach combining the STE test, the EpiOcular assay followed by the BCOP assay (accuracy 69.6%, under prediction rate 8.9%). Moreover, a more favorable predictive capacity (accuracy 71.4%, under prediction rate 3.6%) was obtained when high volatile alcohols/esters with vapor pressures >6 kilopascal (kPa) at 25°C were evaluated with EpiOcular assay instead of the STE test. From these results, the two-stage bottom-up tiered approach combining the STE test, the EpiOcular assay followed by the BCOP assay might be a promising method for the classification of GHS eye irritation category (Not classified (NC), Category 2 (Cat. 2), and Category 1 (Cat. 1)) for a wide range of test chemicals regardless of solubility. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. A reassessment of the in vitro RBC haemolysis assay with defibrinated sheep blood for the determination of the ocular irritation potential of cosmetic products: comparison with the in vivo Draize rabbit test.

    PubMed

    Alves, Eloísa Nunes; Presgrave, Rosaura de Farias; Presgrave, Octávio Augusto França; Sabagh, Fernanda Peres; de Freitas, João Carlos Borges Rolim; Corrado, Alexandre P

    2008-07-01

    We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (DI); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.

  16. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model.

    PubMed

    Kaluzhny, Yulia; Kandárová, Helena; d'Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-08-23

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492.

  17. Eye Irritation Test (EIT) for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial (RhCE) Tissue Model

    PubMed Central

    Kaluzhny, Yulia; Kandárová, Helena; d’Argembeau-Thornton, Laurence; Kearney, Paul; Klausner, Mitchell

    2015-01-01

    To comply with the Seventh Amendment to the EU Cosmetics Directive and EU REACH legislation, validated non-animal alternative methods for reliable and accurate assessment of ocular toxicity in man are needed. To address this need, we have developed an eye irritation test (EIT) which utilizes a three dimensional reconstructed human cornea-like epithelial (RhCE) tissue model that is based on normal human cells. The EIT is able to separate ocular irritants and corrosives (GHS Categories 1 and 2 combined) and those that do not require labeling (GHS No Category). The test utilizes two separate protocols, one designed for liquid chemicals and a second, similar protocol for solid test articles. The EIT prediction model uses a single exposure period (30 min for liquids, 6 hr for solids) and a single tissue viability cut-off (60.0% as determined by the MTT assay). Based on the results for 83 chemicals (44 liquids and 39 solids) EIT achieved 95.5/68.2/ and 81.8% sensitivity/specificity and accuracy (SS&A) for liquids, 100.0/68.4/ and 84.6% SS&A for solids, and 97.6/68.3/ and 83.1% for overall SS&A. The EIT will contribute significantly to classifying the ocular irritation potential of a wide range of liquid and solid chemicals without the use of animals to meet regulatory testing requirements. The EpiOcular EIT method was implemented in 2015 into the OECD Test Guidelines as TG 492. PMID:26325674

  18. The EpiOcular Eye Irritation Test (EIT) for hazard identification and labelling of eye irritating chemicals: protocol optimisation for solid materials and the results after extended shipment.

    PubMed

    Kaluzhny, Yulia; Kandárová, Helena; Handa, Yuki; DeLuca, Jane; Truong, Thoa; Hunter, Amy; Kearney, Paul; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2015-05-01

    The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances. 2015 FRAME.

  19. 78 FR 19413 - Listing of Color Additives Exempt From Certification; Reactive Blue 246 and Reactive Blue 247...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-01

    .... Studies included guinea pig maximization studies, in vivo ocular irritation studies in rabbits, and... C. I. Reactive Blue 247. Studies included guinea pig maximization studies, in vivo ocular irritation...

  20. Promising ion-sensitive in situ ocular nanoemulsion gels of terbinafine hydrochloride: design, in vitro characterization and in vivo estimation of the ocular irritation and drug pharmacokinetics in the aqueous humor of rabbits.

    PubMed

    Tayel, Saadia Ahmed; El-Nabarawi, Mohamed Ahmed; Tadros, Mina Ibrahim; Abd-Elsalam, Wessam Hamdy

    2013-02-25

    Terbinafine hydrochloride (T-HCl) is recommended for the management of fungal keratitis. To maintain effective aqueous humor concentrations, frequent instillation of T-HCl drops is necessary. This work aimed to develop alternative controlled-release in situ ocular drug-loaded nanoemulsion (NE) gels. Twelve pseudoternary-phase diagrams were constructed using oils (isopropyl myristate/Miglyol 812), surfactants (Tween 80/Cremophor EL), a co-surfactant (polyethylene glycol 400) and water. Eight drug-loaded (0.5%, w/v) NEs were evaluated for thermodynamic stability, morphology, droplet size and drug release in simulated tear fluid (pH 7.4). Following dispersion in gellan gum solution (0.2%, w/w), the in situ NE gels were characterized for transparency, rheological behavior, mucoadhesive force, drug release and histopathological assessment of ocular irritation. Drug pharmacokinetics of sterilized F31 [Miglyol 812, Cremophor EL: polyethylene glycol 400 (1:2) and water (5, 55 and 40%, w/w, respectively)] in situ NE gel and oily drug solution were evaluated in rabbit aqueous humor. The NEs were thermodynamically stable and have spherical droplets (<30 nm). The gels were transparent, pseudoplastic, mucoadhesive and showed more retarded zero-order drug release rates. F31 in situ NE gel showed the least ocular irritation potential and significantly (P<0.01) higher C(max), delayed T(max), prolonged mean residence time and increased bioavailability. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. External ocular hyperemia: a quantifiable indicator of spacecraft air quality.

    PubMed

    Ogle, J W; Cohen, K L

    1996-05-01

    Eye irritation consistently ranks as a top astronaut complaint but is difficult to measure. Exposure to internal air pollution hypothetically disrupts the eye's tear film, thereby exposing the crewmembers' conjunctivae to the irritating effects of the recirculated, contaminant-laden atmosphere of the space vehicle. Causes elude engineers and toxicologists, who report that measured irritants remain below established Spacecraft Maximum Allowable Concentrations. Lack of objective ocular endpoints stymies efforts to identify etiologies. Computers offer a practical means of analyzing ocular hyperemia in space. We use computer analysis to quantify redness and blood vessels of digitized images of bulbar conjunctivae in near real time. Custom software masks artifacts, lids and lashes for each photographic or telemedicine ocular image, Algorithms then generate semi-independent measurements of hyperemia. Computed difference scores between 34 pairs of images were compared with subjective difference scores as voted on by a panel of ophthalmology residents. Objective data were reliably extracted from ocular images and significantly correlated (r = 0.583, p < 0.05) with subjective scores. This ground-based methodology generates accurate and reliable ocular endpoint data without mass, volume, or power penalty. To assist in identifying and eliminating onboard ocular irritants, these objective data can be regressed against independent variables such as mission elapsed time, subjective astronaut complaints, levels of chemical and electromagnetic contaminants, nephthelometric and barothermal data. As missions lengthen, sensitive tools such as hyperemia quantification will become increasingly important for assessing and optimizing spacecraft environments.

  2. Ocular Findings in Volcanic Fog Induced Conjunctivitis

    PubMed Central

    Lagunzad, John Kenneth D

    2011-01-01

    Objective To describe the ocular signs and symptoms of patients complaining of eye irritation due to volcanic fog (vog). Methods The study utilized a non-comparative, retrospective chart review of 30 patients who had a chief complaint of eye irritation, which the subjects attributed to vog. Ocular signs and symptoms are described and related to the ambient concentration of sulfur dioxide (SO2), particulate matter sized 2.5 microns (PM2.5), and vog visibility in O‘ahu during the period of the study. Results Ocular signs noted were conjunctival injection (100%), clear mucous discharge (100%), papillary reaction (100%), punctal edema (80%), eyelid swelling (73.3%) and chemosis (63.3%). Ocular symptoms were itchiness (100%), foreign body sensation (100%), tearing (96.6%) and burning sensation (90%). All patients had concurrent respiratory symptoms. During the period of study, the highest 24-hour average concentration of particulate matter sized 2.5 microns (PM2.5) was 49.04 µg/m3 and vog was visually present. Conclusions Patients complaining of eye irritation due to vog have observable ocular signs and symptoms. PMID:22187513

  3. Safety Assessment of Formic Acid and Sodium Formate as Used in Cosmetics.

    PubMed

    Johnson, Wilbur; Heldreth, Bart; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2016-11-01

    Formic acid functions as a fragrance ingredient, preservative, and pH adjuster in cosmetic products, whereas sodium formate functions as a preservative. Because of its acidic properties, formic acid is a dermal and ocular irritant. However, when used as a pH adjuster in cosmetic formulations, formic acid will be neutralized to yield formate salts, for example, sodium formate, thus minimizing safety concerns. Formic acid and sodium formate have been used at concentrations up to 0.2% and 0.34%, respectively, with hair care products accounting for the highest use concentrations of both ingredients. The low use concentrations of these ingredients in leave-on products and uses in rinse-off products minimize concerns relating to skin/ocular irritation or respiratory irritation potential. The Cosmetic Ingredient Review Expert Panel concluded that formic acid and sodium formate are safe in the present practices of use and concentration in cosmetics, when formulated to be nonirritating. © The Author(s) 2016.

  4. [Determination of physicochemical characteristics and evaluation of decontaminating efficacy and in vitro safety of cleaning products for contact lenses].

    PubMed

    Simon, M; Coiffard, L J; Rivalland, P; De Roeck-Holtzhauer, Y

    1996-01-01

    This work aims to characterize products designed for cleaning contact lenses and particularly their physicochemical properties, their efficiency and their ocular irritancy potential compared to the main requirements of eye-washes. The physicochemical controls include pH determination, viscosity and freezing point depression. In addition, we carried out the hydrogen peroxide assay for products containing this active substance. A microbiological control was performed when opening the product and after simulation of a 21-day aging. We determined the decontaminating efficacy of the products on four bacterial strains and a fungal strain. Finally, we tested their ocular allowance by an in vitro test. The pH values obtained ranged from 3.2 (oxygenated water solutions) to 7.6. The viscosity was close to a water solution one (about 1 centipoise). The different assays showed hydrogen peroxide content similar to that stated on the package: rate averaged to 3% and was negligible after neutralization. At opening and after simulation the bacteriological quality was excellent. Finally, decontaminating efficiency against germs was very good for the products tested. The products were classified as non-irritant by the ocular irritancy test. The results obtained show that the products tested met the reference criteria, particularly eye-wash criteria.

  5. CON4EI: CONsortium for in vitro Eye Irritation testing strategy - EpiOcular™ time-to-toxicity (EpiOcular ET-50) protocols for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Kandarova, Helena; Letasiova, Silvia; Adriaens, Els; Guest, Robert; Willoughby, Jamin A; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment for all drivers of classification. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different alternative methods. Here, the results obtained with reconstructed human cornea-like epithelium (RhCE) EpiOcular™ in the EpiOcular time-to-toxicity Tests (Neat and Dilution ET-50 protocols) are presented. The primary aim of this study was to evaluate whether test methods can discriminate chemicals not requiring classification for serious eye damage/eye irritancy (No Category) from chemicals requiring classification and labelling for Category 1 and Category 2. In addition, the predictive capacity in terms of in vivo drivers of classification was investigated. The chemicals were tested in two independent runs by MatTek In Vitro Life Science Laboratories. Results of this study demonstrate very high specificity of both test protocols. With the existing prediction models described in the SOPs, the specificity of the Neat and Dilution method was 87% and 100%, respectively. The Dilution method was able to correctly predicting 66% of GHS Cat 2 chemicals, however, prediction of GHS Cat 1 chemicals was only 47%-55% using the current protocols. In order to achieve optimal prediction for all three classes, a testing strategy was developed which combines the most predictive time-points of both protocols and for tests liquids and solids separately. Using this new testing strategy, the sensitivity for predicting GHS Cat 1 and GHS Cat 2 chemicals was 73% and 64%, respectively and the very high specificity of 97% was maintained. None of the Cat 1 chemicals was underpredicted as GHS No Category. Further combination of the EpiOcular time-to-toxicity protocols with other validated in vitro systems evaluated in this project, should enable significant reduction and even possible replacement of the animal tests for the final assessment of the irritation potential in all of the GHS classes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Functional intercalated nanocomposites with chitosan-glutathione-glycylsarcosine and layered double hydroxides for topical ocular drug delivery.

    PubMed

    Xu, Tingting; Xu, Xiaoyue; Gu, Yan; Fang, Lei; Cao, Feng

    2018-01-01

    To enhance ocular bioavailability, the traditional strategies have focused on prolonging precorneal retention and improving corneal permeability by nano-carriers with positive charge, thiolated polymer, absorption enhancer and so on. Glycylsarcosine (GS) as an active target ligand of the peptide tranpsporter-1 (PepT-1), could specific interact with the PepT-1 on the cornea and guide the nanoparticles to the treating site. The objective of the study was to explore the active targeting intercalated nanocomposites based on chitosan-glutathione-glycylsarcosine (CG-GS) and layered double hydroxides (LDH) as novel carriers for the treatment of mid-posterior diseases. CG-GS-LDH intercalated nanocomposites were prepared by the coprecipitation hydrothermal method. In vivo precorneal retention study, ex vivo fluorescence images, in vivo experiment for distribution and irritation were studied in rabbits. The cytotoxicity and cellular uptake were studied in human corneal epithelial primary cells (HCEpiC). CG-GS-LDH nanocomposites were prepared successfully and characterized by FTIR and XRD. Experiments with rabbits showed longer precorneal retention and higher distribution of fluorescence probe/model drug. In vitro cytological study, CG-GS-LDH nanocomposites exhibited enhanced cellular uptake compared to pure drug solution. Furthermore, the investigation of cellular uptake mechanisms demonstrated that both the active transport by PepT-1 and clathrin-mediated endocytosis were involved in the internalization of CG-GS-LDH intercalated nanocomposites. An ocular irritation study and a cytotoxicity test indicated that these nanocomposites produced no significant irritant effects. The active targeting intercalated nanocomposites could have great potential for topical ocular drug delivery due to the capacity for prolonging the retention on the ocular surface, enhancing the drug permeability through the cornea, and efficiently delivering the drug to the targeted site.

  7. Functional intercalated nanocomposites with chitosan-glutathione-glycylsarcosine and layered double hydroxides for topical ocular drug delivery

    PubMed Central

    Gu, Yan

    2018-01-01

    Background To enhance ocular bioavailability, the traditional strategies have focused on prolonging precorneal retention and improving corneal permeability by nano-carriers with positive charge, thiolated polymer, absorption enhancer and so on. Glycylsarcosine (GS) as an active target ligand of the peptide tranpsporter-1 (PepT-1), could specific interact with the PepT-1 on the cornea and guide the nanoparticles to the treating site. Purpose The objective of the study was to explore the active targeting intercalated nanocomposites based on chitosan-glutathione-glycylsarcosine (CG-GS) and layered double hydroxides (LDH) as novel carriers for the treatment of mid-posterior diseases. Materials and methods CG-GS-LDH intercalated nanocomposites were prepared by the coprecipitation hydrothermal method. In vivo precorneal retention study, ex vivo fluorescence images, in vivo experiment for distribution and irritation were studied in rabbits. The cytotoxicity and cellular uptake were studied in human corneal epithelial primary cells (HCEpiC). Results CG-GS-LDH nanocomposites were prepared successfully and characterized by FTIR and XRD. Experiments with rabbits showed longer precorneal retention and higher distribution of fluorescence probe/model drug. In vitro cytological study, CG-GS-LDH nanocomposites exhibited enhanced cellular uptake compared to pure drug solution. Furthermore, the investigation of cellular uptake mechanisms demonstrated that both the active transport by PepT-1 and clathrin-mediated endocytosis were involved in the internalization of CG-GS-LDH intercalated nanocomposites. An ocular irritation study and a cytotoxicity test indicated that these nanocomposites produced no significant irritant effects. Conclusions The active targeting intercalated nanocomposites could have great potential for topical ocular drug delivery due to the capacity for prolonging the retention on the ocular surface, enhancing the drug permeability through the cornea, and efficiently delivering the drug to the targeted site. PMID:29491707

  8. Glycerogelatin-based ocular inserts of aceclofenac: physicochemical, drug release studies and efficacy against prostaglandin E₂-induced ocular inflammation.

    PubMed

    Mathurm, Manish; Gilhotra, Ritu Mehra

    2011-01-01

    An attempt has been made in the present study to formulate soluble ocular inserts of aceclofenac to facilitate the bioavailability of the drug into the eye, as no eye drop solution could be formulated. Glycero-gelatin ocular inserts/films were prepared and physicochemical parameters and drug release profiles of glycerol-gelatin films of aceclofenac were compared with surface cross-linked films of similar compositions. Ocular irritation of the developed formulation was also checked by HET-CAM test and efficacy of the developed formulation against prostaglandin-induced ocular inflammation in rabbit eye was determined. The non-cross-linked films showed poor mechanical, physicochemical properties, and very little potential of sustaining drug release, however cross-linking the films enhanced tensile strength by 70%, but elasticity decreased by 95%. The cross-linked ocular inserts showed less swelling than non-cross-linked. Formulation AF8 (20% gelatin and 70% glycerin, treated by cross-linker for 1 h) demonstrated the longest drug release for 24 h. As per the kinetic models all films showed a constant drug release with Higuchi diffusion mechanism. Formulation was found to be practically non-irritant. The optimized formulation was tested and compared with eye drops of aceclofenac for anti-inflammatory activity in rabbits against PGE₂-induced inflammation. In vivo studies with developed formulation indicated a significant inhibition of PGE₂-induced PMN migration as compared to eye drops. In conclusion, ocular inserts of aceclofenac was found promising as it achieved sustained drug release and better pharmacodynamic activity.

  9. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    PubMed

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  10. A new cell-based method for assessing the eye irritation potential of chemicals: an alternative to the Draize test.

    PubMed

    Cho, Sun-A; An, Susun; Lee, Eunyoung; Shin, Kyeho; Cho, Jun-Cheol; Lee, Tae Ryong

    2012-07-20

    Using a human corneal cell line (HCE-T cells) and 2 evaluation criteria, we developed a new alternative method to assess the eye irritation potential of chemicals. We exposed HCE-T cells to different concentrations of 38 chemicals for 1h and measured relative cell viability (RCV) as an endpoint at each concentration. Using the RCV values, we calculated the RCV50. We also exposed HCE-T cells to 3 fixed concentrations of the 38 chemicals (5%, 0.5%, and 0.05%) for 1h and measured the RCV at each concentration. Using the RCV values at 5%, 0.5%, and 0.05%, we developed a new criterion for eye irritation potential (total eye irritation score, TEIS) and estimated the ocular irritancy. We then assessed the correlation of the results of RCV50 and TEIS with those of the Draize rabbit eye irritation. Both the RCV50 and TEIS results exhibited good positive correlations (sensitivity: 80.77%, specificity: 83.33%, and accuracy: 81.58% for TEIS; sensitivity: 73.08-76.92%, specificity: 75.00%, and accuracy: 73.68-76.32% for RCV50). We conclude that the new in vitro model using HCE-T cells is a good alternative evaluation model for the prediction of the eye irritation potential of chemicals. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Primary Ocular Irritation Potential of Nitrosoguanidine in Male Rabbits

    DTIC Science & Technology

    1989-09-01

    Markedly deepened rugae , congestion, swelling, moderate circumirldial hyperemia or injection, any of these or any combination thereof, iris still...of the normal luster); inflammation of the iris (other than a slight deepening of the rugae or a slight hyperemia of the circumcomeal blood yessels

  12. Proniosome-derived niosomes for tacrolimus topical ocular delivery: in vitro cornea permeation, ocular irritation, and in vivo anti-allograft rejection.

    PubMed

    Li, Qi; Li, Zhanrong; Zeng, Weidong; Ge, Shumin; Lu, Haoyang; Wu, Chuanbin; Ge, Li; Liang, Dan; Xu, Yuehong

    2014-10-01

    The objective of this study was to develop proniosome-derived niosomes for topical ophthalmic delivery of Tacrolimus (FK506). The FK506 loaded proniosomes containing poloxamer 188 and lecithin as surfactants, cholesterol as a stabilizer, and minimal amount of ethanol and trace water reconstituted to niosomes prior to use. The stability of FK506 loaded proniosomes was assessed, and the morphology, size, zeta potential, surface tension, and entrapment efficiency of the derived niosomes were characterized, indicating they were feasible for instillation in the eyes. The in vitro permeation of FK506 through the freshly excised rabbit cornea, the cumulative permeation amount of FK506 from niosomes, and the drug retention in the cornea all exhibited significant increase as compared to 0.1% FK506 commercial ointments. The in vivo ocular irritation test of 0.1% FK506 loaded niosomes instilled 4 times per day in rat eyes for 21 consecutive days showed no irritation and good biocompatibility with cornea. The in vivo anti-allograft rejection assessment was performed in a Sprague-Dawley (SD) rat corneal xenotransplantation model. The results showed treatment with 0.1% FK506 loaded niosomes delayed the occurrence of corneal allograft rejection and significantly prolonged the median survival time of corneal allografts to13.86±0.80days as compared with those treated with 1% Cyclosporine (CsA) eye drops, drug-free niosomes, or untreated. In conclusion, the proniosome-derived niosomes may be a promising vehicle for effective ocular drug delivery of FK506. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Design and elaboration of freeze-dried PLGA nanoparticles for the transcorneal permeation of carprofen: Ocular anti-inflammatory applications.

    PubMed

    Parra, Alexander; Mallandrich, Mireia; Clares, Beatriz; Egea, María A; Espina, Marta; García, María L; Calpena, Ana C

    2015-12-01

    This work aimed the design and development of poly(lactic-co-glycolic) acid (PLGA) nanoparticles (NPs) for the ocular delivery of Carprofen (CP) by a central rotatable composite design 2(3)+ star. NPs showed adequate size for ocular administration (189.50 ± 1.67 nm), low polydispersity (0.01 ± 0.01), negative charge surface (-22.80 ± 0.66 mV) and optimal entrapment efficiency (74.70 ± 0.95%). Physicochemical analysis confirmed that CP was dispersed inside the NPs. The drug release followed a first order kinetic model providing greater sustained CP release after lyophilization. Ex vivo permeation analysis through isolated rabbit cornea revealed that a sufficient amount of CP was retained in the tissue avoiding excessive permeation and thus, potential systemic levels. Ex vivo ocular tolerance results showed no signs of ocular irritancy, which was also confirmed by in vivo Draize test. In vivo ocular anti-inflammatory efficacy test confirmed an optimal efficacy of NPs and its potential application in eye surgery. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Assessment of ocular discomfort caused by 5 shampoos using the Slug Mucosal Irritation test.

    PubMed

    Petit, Jean-Yanique; Doré, Vanessa; Marignac, Geneviève; Perrot, Sébastien

    2017-04-01

    Assessment of ocular discomfort caused by veterinary care products is less legitimately regulated than that caused by human care products. The Slug Mucosal Irritation (SMI) assay was adapted to evaluate canine hygiene shampoos to predict ocular discomfort. Experiments were performed using four commercial canine shampoos, a baby care product, and two controls (ArtTear® and BAC1%). Groups of 3 slugs were tested with 5% dilution of the 7 test substances. The negative control (ArtTear®) was the best tolerated. The baby care product Mixa bébé as well as Douxo Entretien Démêlant and Phlox Shampooing Entretien were classified to cause mild ocular discomfort. Together with the positive control (BAC 1%), Shampooing Physiologique Virbac and Physiovet Shampooing were considered to cause severe ocular discomfort. Different intensities of ocular discomfort were measured for veterinary care products. The SMI model was considered as a reproducible and adaptable evaluation method for screening veterinary care products causing ocular discomfort. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The Ex Vivo Eye Irritation Test as an alternative test method for serious eye damage/eye irritation.

    PubMed

    Spöler, Felix; Kray, Oya; Kray, Stefan; Panfil, Claudia; Schrage, Norbert F

    2015-07-01

    Ocular irritation testing is a common requirement for the classification, labelling and packaging of chemicals (substances and mixtures). The in vivo Draize rabbit eye test (OECD Test Guideline 405) is considered to be the regulatory reference method for the classification of chemicals according to their potential to induce eye injury. In the Draize test, chemicals are applied to rabbit eyes in vivo, and changes are monitored over time. If no damage is observed, the chemical is not categorised. Otherwise, the classification depends on the severity and reversibility of the damage. Alternative test methods have to be designed to match the classifications from the in vivo reference method. However, observation of damage reversibility is usually not possible in vitro. Within the present study, a new organotypic method based on rabbit corneas obtained from food production is demonstrated to close this gap. The Ex Vivo Eye Irritation Test (EVEIT) retains the full biochemical activity of the corneal epithelium, epithelial stem cells and endothelium. This permits the in-depth analysis of ocular chemical trauma beyond that achievable by using established in vitro methods. In particular, the EVEIT is the first test to permit the direct monitoring of recovery of all corneal layers after damage. To develop a prediction model for the EVEIT that is comparable to the GHS system, 37 reference chemicals were analysed. The experimental data were used to derive a three-level potency ranking of eye irritation and corrosion that best fits the GHS categorisation. In vivo data available in the literature were used for comparison. When compared with GHS classification predictions, the overall accuracy of the three-level potency ranking was 78%. The classification of chemicals as irritating versus non-irritating resulted in 96% sensitivity, 91% specificity and 95% accuracy. 2015 FRAME.

  16. Sleep and mood disorders in dry eye disease and allied irritating ocular diseases.

    PubMed

    Ayaki, Masahiko; Kawashima, Motoko; Negishi, Kazuno; Kishimoto, Taishiro; Mimura, Masaru; Tsubota, Kazuo

    2016-03-01

    The aim of the present study was to evaluate sleep and mood disorders in patients with irritating ocular diseases. The study design was a cross-sectional/case-control study conducted in six eye clinics. Out of 715 outpatients diagnosed with irritating ocular surface diseases and initially enrolled, 301 patients with dry eye disease (DED) and 202 age-matched control participants with other ocular surface diseases were analyzed. The mean Pittsburgh Sleep Quality Index (PSQI) and Hospital Anxiety and Depression Scale (HADS) scores were 6.4 ± 3.2 and 11.1 ± 5.7 for severe DED (n = 146), 5.5 ± 3.3 and 9.8 ± 4.0 for mild DED (n = 155), 5.5 ± 3.1 and 9.5 ± 6.6 for chronic conjunctivitis (n = 124), and 5.0 ± 3.3 and 8.9 ± 5.3 for allergic conjunctivitis (n = 78). There were significant differences among these diagnostic groups for PSQI (P < 0.05). Regression analysis of patients with DED revealed the PSQI and HADS scores were significantly correlated with the severity of DED (P < 0.05). Our results demonstrate that sleep quality in patients with DED is significantly worse than in patients with other irritating ocular surface diseases and it is correlated with the severity of DED.

  17. Primary Ocular Irritation Potential of Ball Powder (Trade Name) in Male Rabbits

    DTIC Science & Technology

    1989-07-01

    rugae , congestion, swelling, moderate circumiridial hyperemia or injection, any of these or any combination thereof, iris still reacting to iight...inflammation of the iris (other than a slight deepening of the rugae or a slight hyperemia of the circumcorneal blood vessels); an obvious swelling in the

  18. Using the Slug Mucosal Irritation Assay to Investigate the Tolerability of Tablet Excipients on Human Skin in the Context of the Use of a Nipple Shield Delivery System.

    PubMed

    Kendall, Richard; Lenoir, Joke; Gerrard, Stephen; Scheuerle, Rebekah L; Slater, Nigel K H; Tuleu, Catherine

    2017-04-01

    Neonates are particularly challenging to treat. A novel patented drug delivery device containing a rapidly disintegrating tablet held within a modified nipple shield (NSDS) was designed to deliver medication to infants during breastfeeding. However concerns exist around dermatological nipple tolerability with no pharmaceutical safety assessment guidance to study local tissue tolerance of the nipple and the areola. This is the first Slug Mucosal Irritation (SMI) study to evaluate irritancy potential of GRAS excipients commonly used to manufacture rapidly disintegrating immediate release solid oral dosage form METHODS: Zinc sulphate selected as the antidiarrheal model drug that reduces infant mortality, was blended with functional excipients at traditional levels [microcrystalline cellulose, sodium starch glycolate, croscarmellose sodium, magnesium stearate]. Slugs were exposed to blends slurried in human breast milk to assess their stinging, itching or burning potential, using objective values such as mucus production to categorize irritation potency RESULTS: Presently an in vivo assay, previously validated for prediction of ocular and nasal irritation, was used as an alternative to vertebrate models to anticipate the potential maternal dermatological tolerability issues to NSDS tablet components. The excipients did not elicit irritancy. However, mild irritancy was observed when zinc sulphate was present in blends. These promising good tolerability results support the continued investigation of these excipients within NSDS rapidly disintegrating tablet formulations. Topical local tolerance effects being almost entirely limited to irritation, the slug assay potentially adds to the existing preformulation toolbox, and may sit in between the in vitro and existing in vivo assays.

  19. Exploration and comparison of in vitro eye irritation tests with the ISO standard in vivo rabbit test for the evaluation of the ocular irritancy of contact lenses.

    PubMed

    Yun, Jun-Won; Hailian, Quan; Na, Yirang; Kang, Byeong-Cheol; Yoon, Jung-Hee; Cho, Eun-Young; Lee, Miri; Kim, Da-Eun; Bae, SeungJin; Seok, Seung Hyeok; Lim, Kyung-Min

    2016-12-01

    In an effort to explore the use of alternative methods to animal testing for the evaluation of the ocular irritancy of medical devices, we evaluated representative contact lenses with the bovine corneal opacity and permeability test (BCOP) and an in vitro eye irritation test using the three-dimensionally-reconstructed human corneal epithelium (RhCE) models, EpiOcular™ and MCTT HCE™. In addition, we compared the obtained results with the ISO standard in vivo rabbit eye irritation test (ISO10993-10). Along with the positive controls (benzalkonium chloride, BAK, 0.02, 0.2, and 1%), the extracts of 4 representative contact lenses (soft, disposable, hard, and colored lenses) and 2 reference lenses (dye-eluting and BAK-coated lenses) were tested. All the lenses, except for the BAK-coated lens, were determined non-irritants in all test methods, while the positive controls yielded relevant results. More importantly, BCOP, EpiOcular™, and MCTT HCE™ yielded a consistent decision for all the tested samples, with the exception of 0.2% BAK in BCOP, for which no prediction could be made. Overall, all the in vitro tests correlated well with the in vivo rabbit eye irritation test, and furthermore, the combination of in vitro tests as a tiered testing strategy was able to produce results similar to those seen in vivo. These observations suggest that such methods can be used as alternative assays to replace the conventional in vivo test method in the evaluation of the ocular irritancy of ophthalmic medical devices, although further study is necessary. Copyright © 2016. Published by Elsevier Ltd.

  20. Effect of polymer viscosity on physicochemical properties and ocular tolerance of FB-loaded PLGA nanospheres.

    PubMed

    Araújo, J; Vega, E; Lopes, C; Egea, M A; Garcia, M L; Souto, E B

    2009-08-01

    Poly(lactide-co-glycolide) acid (PLGA) nanospheres incorporating flurbiprofen (FB) were produced by the solvent displacement technique, for ocular applications aiming to avoid/minimize inflammation induced by surgical trauma. In this work, a PLGA of low viscosity has been tested and the results obtained were compared with those previously reported by Vega et al. The physicochemical properties of the developed formulations were evaluated by measuring particle size, zeta potential and FB entrapment efficiency, showing no significant differences. Release studies demonstrated that the formulation produced with PLGA of higher viscosity revealed a slower drug release rate. Stability analysis, for a period of 75 days, was performed using three complementary methods: (i) turbidity experiments using a Turbiscan optical analyzer, (ii) particle size measurements, and (iii) zeta potential analysis. The results revealed long-term physicochemical stability suitability for ophthalmic use, being independent from the polymer viscosity. The ocular tolerance was assessed by an alternative in vitro method to animal experimentation, the HET-CAM. For all developed formulations no ocular irritancy has been detected.

  1. Corneal Sensitivity in Tear Dysfunction and its Correlation with Clinical Parameters and Blink Rate

    PubMed Central

    Rahman, Effie Z.; Lam, Peter K.; Chu, Chia-Kai; Moore, Quianta; Pflugfelder, Stephen C.

    2015-01-01

    Purpose To compare corneal sensitivity in tear dysfunction due to a variety of causes using contact and non-contact esthesiometers and to evaluate correlations between corneal sensitivity, blink rate and clinical parameters. Design Comparative observational case series. Methods Ten normal and 33 subjects with tear dysfunction [meibomian gland disease (n = 11), aqueous tear deficiency (n = 10) - without (n = 7) and with (n = 3) Sjögren syndrome (SS) and conjunctivochalasis (n = 12)] were evaluated. Corneal sensitivity was measured with Cochet-Bonnet and air jet esthesiometers and blink rate by electromyelography. Eye irritation symptoms, tear meniscus height, tear break-up time (TBUT), and corneal and conjunctival dye staining were measured. Between group means were compared and correlations calculated. Results Compared with control (Cochet-Bonnet 5.45 mm, air esthesiometer 3.62 mg), mean sensory thresholds were significantly higher in aqueous tear deficiency using either Cochet-Bonnet (3.6 mm; P = 0.003) or air (11.7 mg; P = 0.046) esthesiometers, but were not significantly different in the other groups. Reduced corneal sensitivity significantly correlated with more rapid TBUT and blink rate, and greater irritation and ocular surface dye staining with one or both esthesiometers. Mean blink rates were significantly higher in both aqueous tear deficiency and conjunctivochalasis compared with control. Among all subjects, blink rate positively correlated with ocular surface staining and irritation and inversely correlated with TBUT. Conclusion Amongst conditions causing tear dysfunction, reduced corneal sensitivity is associated with greater irritation, tear instability, ocular surface disease and blink rate. Rapid blinking is associated with worse ocular surface disease and tear stability. PMID:26255576

  2. Management of the ocular surface and tear film before, during, and after laser in situ keratomileusis.

    PubMed

    Albietz, Julie M; Lenton, Lee M

    2004-01-01

    To identify evidence-based, best practice strategies for managing the ocular surface and tear film before, during, and after laser in situ keratomileusis (LASIK). After a comprehensive review of relevant published literature, evidence-based recommendations for best practice management strategies are presented. Symptoms of ocular irritation and signs of dysfunction of the integrated lacrimal gland/ocular surface functional gland unit are common before and after LASIK. The status of the ocular surface and tear film before LASIK can impact surgical outcomes in terms of potential complications during and after surgery, refractive outcome, optical quality, patient satisfaction, and the severity and duration of dry eye after LASIK. Before LASIK, the health of the ocular surface should be optimized and patients selected appropriately. Dry eye before surgery and female gender are risk factors for developing chronic dry eye after LASIK. Management of the ocular surface during LASIK can minimize ocular surface damage and the risk of adverse outcomes. Long-term management of the tear film and ocular surface after LASIK can reduce the severity and duration of dry eye symptoms and signs. Strategies to manage the integrated ocular surface/lacrimal gland functional unit before, during, and after LASIK can optimize outcomes. As problems with the ocular surface and tear film are relatively common, attention should focus on the use and improvement of evidence-based management strategies.

  3. Determining the Depth of Injury in Bioengineered Tissue Models of Cornea and Conjunctiva for the Prediction of All Three Ocular GHS Categories

    PubMed Central

    Zorn-Kruppa, Michaela; Houdek, Pia; Wladykowski, Ewa; Engelke, Maria; Bartok, Melinda; Mewes, Karsten R.; Moll, Ingrid; Brandner, Johanna M.

    2014-01-01

    The depth of injury (DOI) is a mechanistic correlate to the ocular irritation response. Attempts to quantitatively determine the DOI in alternative tests have been limited to ex vivo animal eyes by fluorescent staining for biomarkers of cell death and viability in histological cross sections. It was the purpose of this study to assess whether DOI could also be measured by means of cell viability detected by the MTT assay using 3-dimensional (3D) reconstructed models of cornea and conjunctiva. The formazan-free area of metabolically inactive cells in the tissue after topical substance application is used as the visible correlate of the DOI. Areas of metabolically active or inactive cells are quantitatively analyzed on cryosection images with ImageJ software analysis tools. By incorporating the total tissue thickness, the relative MTT-DOI (rMTT-DOI) was calculated. Using the rMTT-DOI and human reconstructed cornea equivalents, we developed a prediction model based on suitable viability cut-off values. We tested 25 chemicals that cover the whole range of eye irritation potential based on the globally harmonized system of classification and labelling of chemicals (GHS). Principally, the MTT-DOI test method allows distinguishing between the cytotoxic effects of the different chemicals in accordance with all 3 GHS categories for eye irritation. Although the prediction model is slightly over-predictive with respect to non-irritants, it promises to be highly valuable to discriminate between severe irritants (Cat. 1), and mild to moderate irritants (Cat. 2). We also tested 3D conjunctiva models with the aim to specifically address conjunctiva-damaging substances. Using the MTT-DOI method in this model delivers comparable results as the cornea model, but does not add additional information. However, the MTT-DOI method using reconstructed cornea models already provided good predictability that was superior to the already existing established in vitro/ex vivo methods. PMID:25494045

  4. Petroleum Jelly: A Novel Medium for Ocular Ultrasound.

    PubMed

    Engelbert, Patrick R; Palma, James K

    2015-08-01

    Ocular ultrasound is a useful emergency department imaging modality for evaluation of many conditions, such as retinal detachment, vitreous detachment, vitreous hemorrhage, and elevated intracranial pressure. Obtaining satisfactory ocular ultrasound images requires the use of a medium that eliminates the air interface between the patient's eye and the transducer. Ultrasound gel is most commonly used; however, the use of a transparent dressing applied to the closed eye prior to the application of gel has also been described as a suitable technique. Ocular ultrasound is performed with the high-frequency linear array transducer using a medium to eliminate the air interface between the eye and the transducer. Although ultrasound gel is most frequently used, it can cause minor eye irritation. Placing a transparent dressing over a closed eye prior to application of gel can eliminate the eye irritation. However, our experience in training >500 students in ocular ultrasound has shown that air is frequently introduced underneath the dressing, which leads to poor-quality images. This article introduces petroleum jelly as a medium for ocular ultrasound. By applying a layer of petroleum jelly over the closed eye and allowing it to warm via body heat for 30 to 45 s, this medium can both minimize patient discomfort and provide easily obtainable, high-quality ocular ultrasound images. This article introduces petroleum jelly as a safe, comfortable, and effective medium for ocular ultrasound examination. Published by Elsevier Inc.

  5. Tear clearance implications for ocular surface health.

    PubMed

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  6. Reprint of "CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals".

    PubMed

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2018-06-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2017-10-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Biopharmaceutical evaluation of epigallocatechin gallate-loaded cationic lipid nanoparticles (EGCG-LNs): In vivo, in vitro and ex vivo studies.

    PubMed

    Fangueiro, Joana F; Calpena, Ana C; Clares, Beatriz; Andreani, Tatiana; Egea, Maria A; Veiga, Francisco J; Garcia, Maria L; Silva, Amélia M; Souto, Eliana B

    2016-04-11

    Cationic lipid nanoparticles (LNs) have been tested for sustained release and site-specific targeting of epigallocatechin gallate (EGCG), a potential polyphenol with improved pharmacological profile for the treatment of ocular pathologies, such as age-related macular edema, diabetic retinopathy, and inflammatory disorders. Cationic EGCG-LNs were produced by double-emulsion technique; the in vitro release study was performed in a dialysis bag, followed by the drug assay using a previously validated RP-HPLC method. In vitro HET-CAM study was carried out using chicken embryos to determine the potential risk of irritation of the developed formulations. Ex vivo permeation profile was assessed using rabbit cornea and sclera isolated and mounted in Franz diffusion cells. The results show that the use of cationic LNs provides a prolonged EGCG release, following a Boltzmann sigmoidal profile. In addition, EGCG was successfully quantified in both tested ocular tissues, demonstrating the ability of these formulations to reach both anterior and posterior segment of the eye. The pharmacokinetic study of the corneal permeation showed a first order kinetics for both cationic formulations, while EGCG-cetyltrimethylammonium bromide (CTAB) LNs followed a Boltzmann sigmoidal profile and EGCG-dimethyldioctadecylammonium bromide (DDAB) LNs a first order profile. Our studies also proved the safety and non-irritant nature of the developed LNs. Thus, loading EGCG in cationic LNs is recognised as a promising strategy for the treatment of ocular diseases related to anti-oxidant and anti-inflammatory pathways. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Dermal Sensitization Potential of Triethyleneglycol Dinitrate (TEGDN) in Guinea Pigs

    DTIC Science & Technology

    1989-01-01

    mutagenicity assay, acute oral toxicity tests in rats and mice, acute dermal toxicity in rabbits, dermal and ocular irritation studies in rabbits, and...conditions: 85E0102 had diffuse tracheitis, mild endocarditis , mild hepatitis, and diffuse pigment granules in the small intestine; 85E0103 had mild...severe ulceration progressing to necrosis. Sensitization is manifested as indirect inflammation mediated by components of the immune system in

  10. CON4EI: Slug Mucosal Irritation (SMI) test method for hazard identification and labelling of serious eye damaging and eye irritating chemicals.

    PubMed

    Adriaens, E; Guest, R; Willoughby, J A; Fochtman, P; Kandarova, H; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. The objective of CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment that can lead to complete replacement of the in vivo Draize rabbit eye test (OECD TG 405). A set of 80 reference chemicals was tested with seven test methods, one method was the Slug Mucosal Irritation (SMI) test method. The method measures the amount of mucus produced (MP) during a single 1-hour contact with a 1% and 10% dilution of the chemical. Based on the total MP, a classification (Cat 1, Cat 2, or No Cat) is predicted. The SMI test method correctly identified 65.8% of the Cat 1 chemicals with a specificity of 90.5% (low over-prediction rate for in vivo Cat 2 and No Cat chemicals). Mispredictions were predominantly unidirectional towards lower classifications with 26.7% of the liquids and 40% of the solids being underpredicted. In general, the performance was better for liquids than for solids with respectively 76.5% vs 57.1% (Cat 1), 61.5% vs 50% (Cat 2), and 87.5% vs 85.7% (No Cat) being identified correctly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. CON4EI: Development of testing strategies for hazard identification and labelling for serious eye damage and eye irritation of chemicals.

    PubMed

    Adriaens, E; Verstraelen, S; Alépée, N; Kandarova, H; Drzewiecka, A; Gruszka, K; Guest, R; Willoughby, J A; Van Rompay, A R

    2018-06-01

    Assessment of acute eye irritation potential is part of the international regulatory requirements for safety testing of chemicals. In the last decades, many efforts have been made in the search for alternative methods to replace the regulatory in vivo Draize rabbit eye test (OECD TG 405). Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. The main objective of the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for serious eye damage and eye irritation assessment that can lead to complete replacement of OECD TG 405. A set of 80 reference chemicals (e.g. balanced by important driver of classification and physical state), was tested with seven test methods. Based on the results of this project, three different strategies were suggested. We have provided a standalone (EpiOcular ET-50), a two-tiered and three-tiered strategy, that can be used to distinguish between Cat 1 and Cat 2 chemicals and chemicals that do not require classification (No Cat). The two-tiered and three-tiered strategies use an RhCE test method (EpiOcular EIT or SkinEthic™ EIT) at the bottom (identification No Cat) in combination with the BCOP LLBO (two-tiered strategy) or BCOP OP-KIT and SMI (three-tiered strategy) at the top (identification Cat 1). For our proposed strategies, 71.1% - 82.9% Cat 1, 64.2% - 68.5% Cat 2 and ≥80% No Cat chemicals were correctly identified. Also, similar results were obtained for the Top-Down and Bottom-Up approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Effects of malicious ocular laser exposure in commercial airline pilots.

    PubMed

    Palakkamanil, Mathew M; Fielden, Michael P

    2015-12-01

    Intentional malicious laser strikes on commercial pilots are committed by individuals who target a laser into airplane cockpits during takeoff and landing. Because laser exposure to pilots is a relatively new but growing occurrence, our study investigates the ocular effect of this laser exposure in pilots. Retrospective chart review by a single ophthalmologist. All commercial airline pilots (58 male, 3 female) who experienced a laser strike while flying between April 2012 and November 2014 who presented to our clinic were included. A retrospective chart review was performed in a retinal specialist's practice. Ocular assessment was performed within 3 days of laser exposure. A complete ophthalmic evaluation was conducted, including Early Treatment Diabetic Retinopathy Study visual acuity, colour vision, visual fields, intraocular pressure, slit-lamp examination, dilated fundus examination, colour fundus photographs, and ocular coherence tomography. Sixty-four laser strike incidents involving commercial pilots were included. All pilots in the study experienced some degree of immediate ocular irritation or light sensitivity. No definite cases of ocular damage were attributed to laser strikes. No pilot had any functional ocular deficits. Our study revealed that laser strikes on aircraft did not result in permanent visual functional or structural deficits. However, laser strikes cause immediate visual effects, including glare, flash blindness, and ocular irritation that can interfere with a pilot's visual function. Given the widespread accessibility of high-power lasers and the rapid increase in incidents, laser strikes threaten to jeopardize aviation safety unless effective preventative measures are put in place. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  13. Promoting effect of borneol on the permeability of puerarin eye drops and timolol maleate eye drops through the cornea in vitro.

    PubMed

    Wu, Chun-jie; Huang, Qin-wan; Qi, Hong-yi; Guo, Ping; Hou, Shi-xiang

    2006-09-01

    Studies on the influence of borneol on the penetration of puerarin eye drops and timolol maleate eye drops through the cornea, and evaluation of the ocular irritability were conducted to provide a theoretical basis for the application of borneol in enhancing corneal permeability. The cornea penetrative experiment in vitro was conducted to observe the quantitative change of puerarin and timolol maleate penetrated through the cornea after administering different dosages of borneol. The corneal hydration level and blinking frequency were recorded as irritability indexes in vitro and in vivo. The steady-flow J of high, middle and low dosage groups of puerarin eye drops with borneol were increased by 49%, 32%, 5% respectively, and permeability parameter Kp increased by 49%, 32%, 5% respectively, as compared to that of the control group. The steady-flow J of high dosage group of timolol maleate eye drops with borneol was increased by 5%; middle and low dosage groups with borneol were decreased by 6%, 3% respectively. The permeability parameter Kp of high dosage group increased by 5%, while middle and low dosage groups with borneol were decreased by 6%, 3% respectively, as compared to that of the control group. Evaluation showed no ocular irritability caused by borneol. The results of this study suggest that the promoting effect of borneol on the permeability of drugs through the cornea in vitro is selective, which indicates that borneol has the potential to be used as an ophthalmic penetration enhancer.

  14. The potential use of novel chitosan-coated deformable liposomes in an ocular drug delivery system.

    PubMed

    Chen, Hongdan; Pan, Hao; Li, Panpan; Wang, Hui; Wang, Xin; Pan, Weisan; Yuan, Yue

    2016-07-01

    In this study, novel chitosan-coated deformable liposomes (DL-CS) were proposed as an ocular drug delivery system to prolong pre-corneal retention, and improve transcorneal penetration and absorption. Flurbiprofen-loaded deformable liposomes (FP-DL) were prepared by a modified ethanol injection method and then coated with chitosan. Both DL and DL-CS exhibited a homogeneous particle size distribution, high encapsulation efficiency and good stability. After coating with 0.1% CS, the zeta potential was shifted from negative to positive. The apparent permeability coefficient of FP-DL-0.1% CS evaluated using isolated rabbit corneas was 1.29-, 1.95- and 4.59- fold greater than that of uncoated FP-DL, conventional liposomes and FP solution (P<0.01), respectively. The in vivo pre-corneal retention time and elimination dynamics were assessed using gamma scintigraphy technology. The area under the remaining activity-time of FP-DL-0.1% CS was prolonged 2.84- and 1.53-fold compared with that of the FP solution and FP-DL groups, respectively. Moreover, the ocular irritation test in vivo revealed that DL-0.1% CS produced no ocular damage or abnormal clinical signs. These results indicate that DL-CS appears to be a novel ophthalmic drug delivery strategy with the potential to overcome the limitations of conventional eye drops. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. General pharmacology of loracarbef in animals.

    PubMed

    Shetler, T; Bendele, A; Buening, M; Clemens, J; Colbert, W; Deldar, A; Helton, D; McGrath, J; Shannon, H; Turk, J

    1993-01-01

    Loracarbef ((6R, 7S)-7-[(R)-2-amino-2-phenyl-acetamido]-3-chloro-8-oxo-1- azabicyclo [4.2.0]oct-2-ene-2-carboxylic acid, monohydrate, LY 163892, CAS 121961-22-6) is a carbacephem antibiotic targeted for use in the treatment of infectious disease. The potential pharmacological effects of this agent were examined on cardiovascular, respiratory, gastrointestinal, central nervous and autonomic nervous systems. Also examined were local anesthetic activity, effects on platelet aggregation, circulating blood glucose, primary antibody production, renal function, blood coagulation, ocular irritation, and the acute inflammatory response. Doses of 100, 1000, and 2000 mg/kg given by the oral route were selected for most in vivo studies. Concentrations up to 3 x 10(-3) mol/l were used in vitro. Loracarbef was essentially inactive in the tests of central and autonomic nervous system function, platelet aggregation, renal function, blood hemolysis, primary antibody production, blood coagulation, and ocular irritation. It had no local anesthetic activity. At high oral or intravenous doses, representing significant multiples of the therapeutic dose, loracarbef caused changes in gastrointestinal (decrease in gastric acid production and gastric fluid volume; increased biliary output), cardiovascular (increased mean pressure, cardiac output, heart rate, and femoral flow), blood glucose (increased glucose levels), and anti-inflammatory tests (suppressed acute inflammatory response). In summary, loracarbef exhibited minimal activity in these pharmacodynamic studies. These results indicate loracarbef has a low potential to produce adverse effects at therapeutic doses.

  16. Novel surface-modified nanostructured lipid carriers with partially deacetylated water-soluble chitosan for efficient ocular delivery.

    PubMed

    Tian, Baocheng; Luo, Qiuhua; Song, Shuangshuang; Liu, Dandan; Pan, Hao; Zhang, Wenji; He, Ling; Ma, Shilin; Yang, Xinggang; Pan, Weisan

    2012-03-01

    The objective of this study was to propose novel surface-modified nanostructured lipid carriers with partially deacetylated water-soluble chitosan (NLC-PDSC) as an efficient ocular delivery system to improve its transcorneal penetration and precorneal retention. PDSC with a deacetylation degree of around 50% was synthesized using an improved method. NLC loaded with flurbiprofen (FB) were prepared by melt emulsification method. They presented spherical morphology under both transmission electron microscope and scanning electron microscope. After coating with 0.15% (w/v) PDSC solution, the NLC showed a core-shell structure and a reversed zeta potential. The enhanced transcorneal penetration of the coated NLC was evaluated using isolated rabbit corneas, with significantly increased apparent permeability coefficient being 1.40- and 1.75-fold of the NLC and FB phosphate solution (FB-sol; p < 0.05), respectively. Precorneal retention assessed by gamma scintigraphy in vivo showed that the area under the remaining activity-time curve of the PDSC-coated formulation was 1.3-fold of the NLC and 2.4-fold of FB-sol. Moreover, in vivo ocular tolerance study indicated that there was no difference in irritation between the coated and noncoated NLC. In conclusion, novel NLC demonstrate high potential for ocular drug delivery. Copyright © 2011 Wiley Periodicals, Inc.

  17. Hyaluronic acid modified chitosan nanoparticles for effective management of glaucoma: development, characterization, and evaluation.

    PubMed

    Wadhwa, Sheetu; Paliwal, Rishi; Paliwal, Shivani R; Vyas, S P

    2010-05-01

    In clinical practices, solution of dorzolamide hydrochloride (DH) and timolol maléate (TM) is recommended for the treatment of glaucoma. However, low drug-contact time and poor ocular bioavailability of drugs due to drainage of solution, tear turnover and its dilution or lacrimation limits its uses. In addition, systemic absorption of TM may induce undesirable cardiovascular side effects. Chitosan (CS) is a polycationic biodegradable polymer which provides sustained and local delivery of drugs to the ocular sites. Hyaluronic acid (HA) also provides synergistic effect for mucoadhesion in association with chitosan. In the present study, hyaluronic acid modified chitosan nanoparticles (CS-HA-NPs) loaded with TM and DH were developed and characterized. The CS-HA-NPs were evaluated for size, shape, zeta potential, entrapment efficiency, and mucoadhesive strength. The in vitro release study was also performed in PBS pH 7.4. The ocular irritation potential of CS-HA-NPs was estimated using draize test on albino rabbits. A significant reduction in IOP level was obtained using CS-HA-NPs as compared to plain solution of drug and a comparable higher reduction in IOP level was observed as to CS-NPs. These results suggest that HA potentialy enhance the mucoadhesiveness and efficiency of CS-NPs and may be promising carrier for ocular drug delivery.

  18. Evaluation of a three-dimensional human dermal model as a predictor of shampoo ocular irritation.

    PubMed

    Decker, D; Harper, R

    1994-04-01

    A three-dimensional human tissue model (Skin(2) ZK1100) was used to evaluate 43 adult and baby shampoos. The ZK1100 model consists of metabolically active proliferating human fibroblasts isolated from the dermis of neonatal foreskins and seeded onto a nylon mesh. The fibroblasts multiply and produce matrix proteins to form a living tissue. MTT reduction (mitochondrial function) was used as the cytotoxicity endpoint. The primary components of the adult shampoos are alkyl sulfate surfactants, while the baby shampoos contain ethoxylated alkyl sulfates and amphoteric surfactants. All shampoos were diluted to five concentrations (100, 300, 700, 1000 and 3000 mug/ml) in aqueous cell culture media and the tissue exposed for 24 hr. An EC(50) value for each test was generated from a dose-response curve. All samples were tested in two or more separate experiments, and the EC(50) values were averaged and plotted versus their respective 24-hr unwashed Draize eye irritation values (r(2) = 0.81). The adult shampoos had Draize values in the moderate irritation category and EC(50) values ranging from 220 to 1051 mug/ml, while the baby shampoos had Draize values in the minimal irritation category and EC(50) values ranging from 820 to 2285 mug/ml. These results indicate that the three-dimensional human tissue model can be useful in predicting the Draize ocular irritation category for shampoos.

  19. Postanaesthetic tear production and ocular irritation in cats.

    PubMed

    Peche, N; Köstlin, R; Reese, S; Pieper, K

    2015-01-01

    General anaesthesia significantly reduces tear production and normal values are not immediately re-established on ending anaesthesia. Therefore, adequate protection of the cornea has to be assured during the perianaesthetic period. There are various methods available, including taping of the eyelids and the application of eye ointments, gels and drops. In human medicine studies, different formulations were found to induce signs of ocular irritation. The aim of the present study was to determine tear production in cats after general anaesthesia, and to identify possible causes of irritation. Tear production was determined in 41 cats after general anaesthesia and eyes were examined for signs of irritation. Two different anaesthetic protocols were used. To protect the cornea, an ointment and gel were applied to the right and left eyes, respectively. Postoperatively, tear production was significantly reduced for 6 hours and 18 hours in the right and left eyes, respectively. Two hours after anaesthesia, blepharospasm of the right eye was observed in 92.7% (n = 38) of the cats. In contrast, the left eye was always held open. This study demonstrated that tear production in cats is significantly decreased both during and after anaesthesia. The degree of reduction was independent of the anaesthetic protocol. Both the eye ointment and gel proved effective in protecting the corneal surface. However, eye gel use is recommended because the eye ointment consistently caused an irritation comparable to the foreign-body sensation reported in humans.

  20. Efficacy and Safety of Carbomer-Based Lipid-Containing Artificial Tear Formulations in Patients With Dry Eye Syndrome.

    PubMed

    Chung, So-Hyang; Lim, Sung A; Tchach, Hungwon

    2016-02-01

    To evaluate the efficacy and safety profile of carbomer-based lipid-containing artificial tear formulations (CBLAT) in patients with dry eye syndrome. A multicenter parallel-group study was conducted in 412 patients with dry eye syndrome. Of these patients, 221 switched from using artificial tears to CBLAT (switching group) and 191 added CBLAT to their current treatment (add-on group). Ocular symptom scores, ocular staining grades, tear film breakup time (tBUT), Schirmer I test value, and Korean dry eye level (as defined by the Korean Corneal Disease Study Group guidelines) were evaluated at baseline and after 4 weeks of treatment. After 4 weeks of treatment, ocular surface staining grade, tBUT, Schirmer I value, ocular irritation symptom scores, and the positive rate of visual symptom improved significantly in both groups. Mean reductions in ocular surface staining grades (-0.8 ± 0.9) and ocular irritation symptom scores (-0.8 ± 0.8) in the add-on group were significantly higher than those (-0.5 ± 0.8 and -0.6 ± 0.8) in the switching group (P < 0.01 and P < 0.05). The positive rate of visual symptoms (44.2%) in the add-on group was significantly higher than that (26.4%) in the switching group (P < 0.01). The decrease of Korean dry eye level was 30.1% in the switching group and 51.6% in the add-on group. More patients in the add-on group had decreased dry eye levels than those in the switching group (P < 0.0001). CBLAT improves ocular surface staining grades, tBUT, Schirmer I values, and ocular symptoms in patients with dry eye syndrome.

  1. New vehicle based on a microemulsion for topical ocular administration of dexamethasone.

    PubMed

    Fialho, Sílvia Ligório; da Silva-Cunha, Armando

    2004-12-01

    Eye drops are the most used dosage form by the ocular route, in spite of their low bioavailability. Due to their properties and numerous advantages, microemulsions are promising systems for topical ocular drug delivery. They can increase water solubility of the drug and enhance drug absorption into the eye. The present study describes the development and characterization of an oil-in-water microemulsion containing dexamethasone and the evaluation of its pharmacokinetics in rabbits after topical ocular application. The microemulsion was prepared by the titration technique. Its physico-chemical characteristics and stability were determined. The ocular irritation test and the pharmacokinetics of this system were studied in white rabbits. The developed system showed an acceptable physico-chemical behaviour and presented good stability for 3 months. The ocular irritation test used suggested that the microemulsion did not provide significant alteration to eyelids, conjunctiva, cornea and iris. This formulation showed greater penetration of dexamethasone in the anterior segment of the eye and also release of the drug for a longer time when compared with a conventional preparation. The area under the curve obtained for the microemulsion system was more than twofold higher than that of the conventional preparation (P < 0.05). The microemulsion-based dexamethasone eye drop is advantageous for ophthalmic use because it is well-tolerated in the eye and seemed to provide a higher degree of bioavailability. The developed system shows greater penetration in the eye, allowing the possibility of decreasing the number of applications of eye drops per day.

  2. CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Van Rompay, A R; Alépée, N; Nardelli, L; Hollanders, K; Leblanc, V; Drzewiecka, A; Gruszka, K; Guest, R; Kandarova, H; Willoughby, J A; Verstraelen, S; Adriaens, E

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement and a necessary step in the safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as a stand-alone assay. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed with the goal of assessing the reliability of eight in vitro/alternative test methods as well as establishing an optimal tiered-testing strategy. One of the in vitro assays selected was the validated SkinEthic™ Human Corneal Epithelium Eye Irritation Test method (SkinEthic™ HCE EIT). The SkinEthic™ HCE EIT has already demonstrated its capacity to correctly identify chemicals (both substances and mixtures) not requiring classification and labelling for eye irritation or serious eye damage (No Category). The goal of this study was to evaluate the performance of the SkinEthic™ HCE EIT test method in terms of the important in vivo drivers of classification. For the performance with respect to the drivers all in vivo Cat 1 and No Cat chemicals were 100% correctly identified. For Cat 2 chemicals the liquids and the solids had a sensitivity of 100% and 85.7%, respectively. For the SkinEthic™ HCE EIT test method, 100% concordance in predictions (No Cat versus No prediction can be made) between the two participating laboratories was obtained. The accuracy of the SkinEthic™ HCE EIT was 97.5% with 100% sensitivity and 96.9% specificity. The SkinEthic™ HCE EIT confirms its excellent results of the validation studies. Copyright © 2017. Published by Elsevier Ltd.

  3. Noninvasive spectroscopic diagnosis of superficial ocular lesions and corneal infections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mourant, J.R.; Bigio, I.J.; Johnson, T.

    The potential of a rapid noninvasive diagnostic system to detect tissue abnormalities on the surface of the eye has been investigated. The optical scatter signal from lesions and normal areas on the conjunctival sclera of the human eye were measured in vivo. It is possible to distinguish nonpigmented pingueculas from other lesions. The ability of the system to detect malignancies could not be tested because none of the measured and biopsied lesions were malignant. Optical scatter and fluorescence spectra of bacterial and fungal suspensions, and corneal irritations were also collected. Both scattering and fluorescence show potential for diagnosing corneal infections.

  4. Chronic Lunar Dust Exposure on Rat Cornea: Evaluation by Gene Expression Profiling

    NASA Technical Reports Server (NTRS)

    Theriot, C. A.; Glass, A.; Lam, C-W.; James, J.; Zanello, S. B.

    2014-01-01

    Lunar dust is capable of entering habitats and vehicle compartments by sticking to spacesuits or other objects that are transferred into the spacecraft from the lunar surface and has been reported to cause irritation upon exposure. During the Apollo missions, crewmembers reported irritation specifically to the skin and eyes after contamination of the lunar and service modules. It has since been hypothesized that ocular irritation and abrasion might occur as a result of such exposure, impairing crew vision. Recent work has shown that both ultrafine and unground lunar dust exhibited minimal irritancy of the ocular surface (i.e., cornea); however, the assessment of the severity of ocular damage resulting from contact of lunar dust particles to the cornea has focused only on macroscopic signs of mechanical irritancy and cytotoxicity. Given the chemical reactive properties of lunar dust, exposure of the cornea may contribute to detrimental effects at the molecular level including but not limited to oxidative damage. Additionally, low level chronic exposures may confound any results obtained in previous acute studies. We report here preliminary results from a tissue sharing effort using 10-week-old Fischer 344 male rats chronically exposed to filtered air or jet milled lunar dust collected during Apollo 14 using a Jaeger-NYU nose-only chamber for a total of 120 hours (6 hours daily, 5 days a week) over a 4-week period. RNA was isolated from corneas collected from rats at 1 day and 7 days after being exposed to concentrations of 0, 20, and 60 mg/m3 of lunar dust. Microarray analysis was performed using the Affymetrix GeneChip Rat Genome 230 2.0 Array with Affymetrix Expression Console and Transcriptome Analysis Console used for normalization and secondary analysis. An Ingenuity iReport"TM" was then generated for canonical pathway identification. The number of differentially expressed genes identified increases with dose compared to controls suggesting a more severe response to the lunar dust insult at higher levels. Pathways of interests that have been identified in all exposed samples include oxidative stress response, mitochondrial dysfunction, fibrosis, epithelial healing, TGF-Beta? signaling, and extracellular matrix remodeling. Several biological processes related to cell migration, cellular proliferation, and eye development were also identified to be altered by exposure to lunar dust. Our preliminary results suggest that even a chronic insult of lunar dust as low as 20 mg/m(exp 3) elicits a molecular response in cornea tissue. Lunar dust on the surface of the moon would have the added properties of ionization and activation potentially leading to further damage to the cornea and greater sensitivity to any other environmental insult such as exposure to radiation. Additional studies are required to fully assess the risk of vision impairment and the mechanistic responses initiated in cornea exposed to lunar dust as well as the potential for long-term effects to astronaut health

  5. Neuropathic ocular pain: an important yet underevaluated feature of dry eye

    PubMed Central

    Galor, A; Levitt, R C; Felix, E R; Martin, E R; Sarantopoulos, C D

    2015-01-01

    Dry eye has gained recognition as a public health problem given its prevalence, morbidity, and cost implications. Dry eye can have a variety of symptoms including blurred vision, irritation, and ocular pain. Within dry eye-associated ocular pain, some patients report transient pain whereas others complain of chronic pain. In this review, we will summarize the evidence that chronicity is more likely to occur in patients with dysfunction in their ocular sensory apparatus (ie, neuropathic ocular pain). Clinical evidence of dysfunction includes the presence of spontaneous dysesthesias, allodynia, hyperalgesia, and corneal nerve morphologic and functional abnormalities. Both peripheral and central sensitizations likely play a role in generating the noted clinical characteristics. We will further discuss how evaluating for neuropathic ocular pain may affect the treatment of dry eye-associated chronic pain. PMID:25376119

  6. Optical response of the cultured bovine lens; testing opaque or partially transparent semi-solid/solid common consumer hygiene products.

    PubMed

    Wong, W; Sivak, J G; Moran, K L

    2003-01-01

    This study determines the relative ocular lens irritancy of 16 common partially transparent or non-transparent consumer hygiene products. The irritancy was found by measuring the changes in the sharpness of focus [referred to as the back vertex distance (BVD) variability] of the cultured bovine lens using a scanning laser In Vitro Assay System. This method consists of a laser beam that scans across the lens, and a computer, which then analyses the average focal length (mm), the BVD variability (mm), and the intensity of the beam transmitted. Lenses were exposed to the 16 hygiene products and the lens' focusing ability was monitored over 192 h. The products are semi-solids or solids (e.g. gels, lotions, shampoos). They are categorized into six groups: shampoos, body washes, lotions, toothpastes, deodorant, and anti-perspirant. Damage (measured by > 1 mm BVD variability) occurred slower for the shampoos, especially in the case of baby shampoo. The results indicate that shampoos exhibit the lowest level of ocular lens toxicity (irritability) while the deodorant is the most damaging.

  7. Dry eye disease: an immune-mediated ocular surface disorder

    PubMed Central

    Stevenson, William; Chauhan, Sunil K.; Dana, Reza

    2013-01-01

    Dry eye disease is a multifactorial disorder of the tears and ocular surface characterized by symptoms of dryness and irritation. Although the pathogenesis of dry eye disease is not fully understood, it is recognized that inflammation has a prominent role in the development and propagation of this debilitating condition. Factors that adversely affect tear film stability and osmolarity can induce ocular surface damage and initiate an inflammatory cascade that generates innate and adaptive immune responses. These immunoinflammatory responses lead to further ocular surface damage and the development of a self-perpetuating inflammatory cycle. Herein, we review the fundamental links between inflammation and dry eye disease and discuss the clinical implications of inflammation in disease management. PMID:22232476

  8. Ocular demodicosis as a potential cause of pediatric blepharoconjunctivitis.

    PubMed

    Liang, Lingyi; Safran, Steve; Gao, Yingying; Sheha, Hosam; Raju, V K; Tseng, Scheffer C G

    2010-12-01

    To report Demodex infestation in pediatric blepharoconjunctivitis. A retrospective review of 12 patients, with ages from 2.5-11 years, with chronic blepharoconjunctivitis who failed to respond to conventional treatments. Demodex was detected by lash sampling and microscopic examination. Patients were treated with 50% tea tree oil (TTO) eyelid scrubs or 5% TTO ointment eyelid massages for 4-6 weeks. Demodex mites were found in all, but 1 case had cylindrical dandruff in the lashes. After 1 week of TTO treatment, all patients showed dramatic resolution of ocular irritation and inflammation while Demodex counts dropped. All corneal signs resolved within 2 weeks except for a residual anterior stromal scar in 1 eye. During a follow-up period of 8.3 ± 4.6 months, 1 patient showed recurrent inflammation, which was successfully managed by a second round of TTO treatment. Demodicosis should be considered as a potential cause of pediatric refractory blepharoconjunctivitis. Eyelid scrubs or massage with TTO could be an effective treatment regimen in these cases.

  9. Lipid Nanocarrier: an Efficient Approach Towards Ocular Delivery of Hydrophilic Drug (Valacyclovir).

    PubMed

    Kumar, Rakesh; Sinha, V R

    2017-04-01

    This research focuses on the fabrication and evaluation of solid lipid nanoparticles (SLNs) for improved ocular delivery of valacyclovir (VAC). Stearic acid and tristearin were selected as the lipid carrier while Poloxamer 188 and sodium taurocholate were used as surfactant and co-surfactant, respectively. The physiochemical properties of the optimized batch (SLN-6) fulfil the prerequisites needed for an ideal ocular formulation like submicron size (202.5 ± 2.56 nm), narrow PDI (0.252 ± 0.06), high zeta potential (-34.4 ± 3.04 mV) and good entrapment efficiency (58.82 ± 2.45%). The in vitro release study of SLN-6 exhibited a sustained release profile (>60% in 12 h). The ex vivo studies performed on excised cornea exhibited enhanced drug permeation of SLNs (22.17 ± 1.41 μg/cm 2  h) in comparison to the drug solution (3.78 ± 1.34 μg/cm 2  h). Apart, the corneal hydration studies, histopathology and Hen's Egg Test Chorio Allantoic Membrane (HETCAM) assay, confirmed the non-irritancy of SLNs. The in vivo study confirmed improved ocular bioavailability of VAC from SLN-6 (AUC 0-12 : 856.47 ± 7.86 μg h/mL) in contrast to the drug solution (AUC 0-12 : 470.75 ± 8.91 μg h/mL). Hence, the overall studies suggested the potential of SLNs in efficient ocular delivery of a hydrophilic molecule like VAC.

  10. CON4EI: Evaluation of QSAR models for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Geerts, L; Adriaens, E; Alépée, N; Guest, R; Willoughby, J A; Kandarova, H; Drzewiecka, A; Fochtman, P; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritation is a regulatory requirement in safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as stand-alone assays. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed to assess the reliability of eight in vitro test methods and computational models as well as establishing an optimal tiered-testing strategy. For three computational models (Toxtree, and Case Ultra EYE_DRAIZE and EYE_IRR) performance parameters were calculated. Coverage ranged from 15 to 58%. Coverage was 2 to 3.4 times higher for liquids than for solids. The lowest number of false positives (5%) was reached with EYE_IRR; this model however also gave a high number of false negatives (46%). The lowest number of false negatives (25%) was seen with Toxtree; for liquids Toxtree predicted the lowest number of false negatives (11%), for solids EYE_DRAIZE did (17%). It can be concluded that the training sets should be enlarged with high quality data. The tested models are not yet sufficiently powerful for stand-alone evaluations, but that they can surely become of value in an integrated weight-of-evidence approach in hazard assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Corneal Sensitivity and Presence of Pathogenic Organisms Among Participants Who Have Undergone Trichiasis Surgery Differ by Surgical Outcome.

    PubMed

    Schein, Yvette; Harding, Jennifer C; Merbs, Shannath L; Cassard, Sandra D; Mabula, Kasubi; Othman, Majid S; West, Sheila K; Gower, Emily W

    2016-04-01

    To explore the potential association between reduced corneal sensation and/or conjunctival bacterial colonization and postoperative trichiasis and eyelid contour abnormalities after corrective eyelid surgery among participants with a history of trachomatous trichiasis. As an ancillary study to the Partnership for Rapid Elimination of Trachoma (PRET) Surgery Trial in southern Tanzania, we collected data on 580 PRET participants who had undergone trichiasis surgery 1 year earlier and 200 age-group-matched individuals without trichiasis. Assessments included eyelid status evaluation (presence and severity of postoperative trichiasis and/or eyelid contour abnormality), corneal sensitivity by Cochet-Bonnet aesthesiometer, a questionnaire on symptoms of ocular irritation, and conjunctival microbiology. We divided PRET participants based on their eyelid status and compared results across PRET groups and versus normals. PRET participants had reduced corneal sensitivity compared with age-matched normals (mean sensitivity ranged from 2.8 to 3.8 cm in PRET participants vs. 5.9 cm in normals), and increasing severity of postoperative trichiasis was associated in a stepwise fashion with reduced corneal sensitivity (mean = 3.5 cm for mild and 2.6 cm for severe postoperative trichiasis). Conjunctival colonization with pathogenic bacteria was also associated with more severe postoperative trichiasis (Cochran-Armitage trend test P = 0.001) and with reduced corneal sensitivity (trend test P < 0.0001). Symptoms of ocular irritation were not associated with previous trichiasis surgery, postoperative trichiasis, or eyelid contour abnormality. These findings indicate that reduced corneal sensitivity accompanies trachomatous trichiasis and suggest that reduced corneal sensitivity may play an important role in the harboring of pathogenic bacteria on the ocular surface.

  12. Oleoresin capsicum (Cap-Stun) toxicity from aerosol exposure.

    PubMed

    Watson, W A; Stremel, K R; Westdorp, E J

    1996-01-01

    To describe the clinical toxicity caused by oleoresin capsicum (OC) spray during law-enforcement action. A medical record review. Emergency department (ED), Truman Medical Center, Kansas City, MO. Consecutive patients who presented to the ED after OC-spray exposure from law-enforcement action between June 1991 and June 1994. Patient presentation and symptoms at presentation, evaluation, and treatment during ED stay. Eighty-one ED patients, approximately 10% of all individuals sprayed by police officers, presented after exposure to OC. Ocular burning and redness were the most common presenting symptoms. None of the patients required hospitalization due to OC toxicity. Corneal abrasions and respiratory symptoms occurred in 7 and 6 patients, respectively. The need for ED evaluation and treatment was infrequent after exposure to OC. A transient burning sensation, erythema, and localized irritation were the most common findings. While no patients had adverse outcomes attributed to OC exposure, practitioners assessing exposure should consider the potential for pulmonary and ocular toxicity.

  13. Randomised masked trial of the clinical safety and tolerability of MGO Manuka Honey eye cream for the management of blepharitis

    PubMed Central

    Craig, Jennifer P; Wang, Michael T M; Ganesalingam, Kalaivarny; Rupenthal, Ilva D; Swift, Simon; Loh, Chee Seang; Te Weehi, Leah; Cheung, Isabella M Y; Watters, Grant A

    2017-01-01

    Objective To assess the clinical safety and tolerability of a novel MGO Manuka Honey microemulsion (MHME) eye cream for the management of blepharitis in human subjects. Methods and analysis Twenty-five healthy subjects were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. The MHME eye cream (Manuka Health New Zealand) was applied to the closed eyelids of one eye (randomised) overnight for 2 weeks. LogMAR visual acuity, eyelid irritation symptoms, ocular surface characteristics and tear film parameters were assessed at baseline, day 7 and day 14. Expression of markers of ocular surface inflammation (matrix metalloproteinase-9 and interleukin-6) and goblet cell function (MUC5AC) were quantified using impression cytology at baseline and day 14. Results There were no significant changes in visual acuity, eyelid irritation symptoms, ocular surface characteristics, tear film parameters and inflammatory marker expression during the 2-week treatment period in treated and control eyes (all p>0.05), and measurements did not differ significantly between eyes (all p>0.05). No major adverse events were reported. Two subjects experienced transient ocular stinging, presumably due to migration of the product into the eye, which resolved following aqueous irrigation. Conclusion The MHME eye cream application was found to be well tolerated in healthy human subjects and was not associated with changes in visual acuity, ocular surface characteristics, tear film parameters, expression of markers of inflammation or goblet cell function. The findings support future clinical efficacy trials in patients with blepharitis. Trial registration number ACTRN12616000540415 PMID:29354710

  14. Influence of different surfactants on the technological properties and in vivo ocular tolerability of lipid nanoparticles.

    PubMed

    Leonardi, Antonio; Bucolo, Claudio; Romano, Giovanni Luca; Platania, Chiara Bianca Maria; Drago, Filippo; Puglisi, Giovanni; Pignatello, Rosario

    2014-08-15

    Addition of one or more surfactant agents is often necessary for the production of nanostructured lipid and polymeric systems. The removal of residual surfactants is a required step for technological and toxicological reasons, especially for peculiar applications, such as the ophthalmic field. This study was planned to assess the technological properties of some surfactants, commonly used for the production of lipid nanoparticles, as well as their ocular safety profile. Stable and small-size solid lipid nanoparticles were obtained using Dynasan(®) 114 as the lipid matrix and all the tested surfactants. However, from a toxicological point of view, the nanocarriers produced using Kolliphor(®) P188 were the most valuable, showing no irritant effect on the ocular surface up to the highest tested surfactant concentration (0.4%, w/v). The SLN produced using Cremophor(®) A25 and Lipoid(®) S100 were tolerated up to a surfactant concentration of 0.2% by weight, while for Tween(®) 80 and Kolliphor(®) HS 15 a maximum concentration of 0.05% can be considered totally not-irritant. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. CON4EI: Development of serious eye damage and eye irritation testing strategies with respect to the requirements of the UN GHS/EU CLP hazard categories.

    PubMed

    Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    The main objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project (2015-2016) was to develop tiered, non-animal testing strategies for serious eye damage and eye irritation assessment in relation to the most important drivers of classification. The serious eye damage and eye irritation potential of a set of 80 chemicals was identified based on existing in vivo Draize eye test data and testing was conducted using the following eight alternative test methods: BCOP (Bovine Corneal Opacity and Permeability)+histopathology, BCOP-LLBO (BCOP Laser Light-Based Opacitometer), ICE (Isolated Chicken Eye)+histopathology, STE (Short Term Exposure), EpiOcular™ EIT (EpiOcular Eye Irritation Test), EpiOcular™ ET-50 (EpiOcular™ Time-to-toxicity), SkinEthic™ HCE EIT (SkinEthic™ Human Corneal Epithelial Eye Irritation Test), and SMI (Slug Mucosal Irritation). Project management decided to not include the ICE data in this project since the execution showed relevant, and not predictable, deviations from Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 438 and Guidance Document 160. At this stage, the outcome of these deviations has not been fully assessed. In addition to these alternative test methods, the computational models Toxtree and Case Ultra were taken into account. This project assessed the relevance of these test methods, their applicability domains and limitations in terms of 'drivers of classification', and their strengths and weaknesses. In this way, methods were identified that fit into a tiered-testing strategy for serious eye damage/eye irritation assessment to distinguish United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) Category 1 (Cat 1) chemicals from non-Cat 1 chemicals and address the gap namely distinguish between Category 2 (Cat 2) and Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Vitrigel-eye irritancy test method using HCE-T cells.

    PubMed

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2013-10-01

    We previously reported that the time-dependent relative changes of transepithelial electrical resistance (TEER) after exposing four different chemicals to a human corneal epithelium (HCE) model were well correlated to the potential of ocular irritancy. Meanwhile, we recently developed a collagen vitrigel membrane (CVM) chamber possessing a scaffold composed of high-density collagen fibrils equivalent to connective tissues in vivo as a three-dimensional culture tool. The CVM chamber is useful for biomedical assays and immunohistology using cryosections that are inappropriate to be performed using the conventional Millicell chamber with a polyethylene terephthalate membrane. In this study, we aimed to develop a new eye irritancy test (EIT) method called "Vitrigel-EIT method" that can facilitate to briefly and accurately estimate the widespread irritancy of test chemicals by applying the TEER assay system to a HCE model fabricated in the CVM chamber. HCE-T cells (a HCE-derived cell strain) were cultured in the CVM chamber for 6 days, and consequently, the Vitrigel-HCE model possessing the following characteristics of HCE in vivo was formed: six cell layers with specific protein expressions and their barrier function. Time-dependent profiles of TEER values after exposing 30 test chemicals to the HCE model were converted into the scores of three indexes (time lag, intensity, and plateau level), and each chemical was successfully classified into irritant or nonirritant category by utilizing the criteria for the indexes, resulting in the excellent correlation with Globally Harmonized System of Classification and Labelling of Chemicals (GHS) classification (sensitivity: 100%, specificity: 75%, accuracy: 90%). These data suggest that the widespread eye irritancy of chemicals can be predicted without false negatives by the Vitrigel-EIT method. Interestingly, the disruption of tight junctions was immunohistologically observed after exposing not only irritants but also three compounds classified as nonirritant by GHS but found positive in our Vitrigel-EIT method confirming a possible mild irritant property.

  17. Ocular Toxicity Secondary to Asclepias physocarpa: The Balloon Plant.

    PubMed

    Pina, Susana; Pedrosa, Catarina; Santos, Cristina; Feijóo, Bernardo; Pego, Peter; Vendrell, Cristina; Santos, Maria João; Prieto, Isabel

    2014-01-01

    We report a case of a 65-year-old woman with symptoms of blurred vision and ocular irritation a few hours after accidental contact of the right eye with Asclepias physocarpa milky latex. Observation showed a diffuse conjunctival hyperemia and stromal corneal edema with Descemet's membrane folds. Recovery was fast and apparently complete in less than one month. However, specular microscopy at 6-months follow-up showed an abnormal endothelial morphology as sequelae, suggesting this condition is not as innocuous as it has been suggested.

  18. A nanomedicine to treat ocular surface inflammation: performance on an experimental dry eye murine model.

    PubMed

    Contreras-Ruiz, L; Zorzi, G K; Hileeto, D; López-García, A; Calonge, M; Seijo, B; Sánchez, A; Diebold, Y

    2013-05-01

    MUC5AC is a glycoprotein with gel-forming properties, whose altered expression has been implicated in the pathogenesis of dry eye disease. The aim of our study was to achieve an efficient in vivo transfection of MUC5AC, restore its normal levels in an inflamed ocular surface and determine whether restored MUC5AC levels improve ocular surface inflammation. Cationized gelatin-based nanoparticles (NPs) loaded with a plasmid coding a modified MUC5AC protein (pMUC5AC) were instilled in healthy and experimental dry eye (EDE) mice. MUC5AC expression, clinical signs, corneal fluorescein staining and tear production were evaluated. Ocular specimens were processed for histopathologic evaluation, including goblet cell count and CD4 immunostaining. Neither ocular discomfort nor irritation was observed in vivo after NP treatment. Expression of modified MUC5AC was significantly higher in ocular surface tissue of pMUC5AC-NP-treated animals than that of controls. In healthy mice, pMUC5AC-NPs had no effect on fluorescein staining or tear production. In EDE mice, both parameters significantly improved after pMUC5AC-NP treatment. Anterior eye segment of treated mice showed normal architecture and morphology with lack of remarkable inflammatory changes, and a decrease in CD4+ T-cell infiltration. Thus, pMUC5AC-NPs were well tolerated and able to induce the expression of modified MUC5A in ocular surface tissue, leading to reduction of the inflammation and, consequently improving the associated clinical parameters, such as tear production and fluorescein staining. These results identify a potential application of pMUC5AC-NPs as a new therapeutic modality for the treatment of dry eye disease.

  19. Dry powder dosing in liquid vehicles: ocular tolerance and scintigraphic evaluation of a perfluorocarbon suspension.

    PubMed

    Zhu, Y; Wilson, C G; Meadows, D; Olejnik, O; Frier, M; Washington, N; Musson, R

    1999-11-30

    The ocular tolerance and precorneal disposition of 99mTc-labelled sterile carbon-perfluorodecalin (PFD) and carbon-aqueous suspensions were examined in a cohort of healthy volunteers. Formulations were prepared in PFD or saline using charcoal particles, radiolabelled with [99mTc]diethylenetriaminepentaacetic acid (DTPA) under GMP conditions. Colloidal silicon dioxide was used as a suspending agent. Ocular tolerance was examined following the instillation of each formulation to the eyes of 12 volunteers. The precorneal distribution of both formulations in man was monitored using gamma scintigraphy. Dynamic and static data acquisitions were taken over a period of 150 min after dosing. Carbon particulates suspended in PFD did not show any irritation to the eye. Administration of PFD formulation in man produced a significant increase in ocular retention over a saline formulation (mean residence time (MRT)=157+/-42 and 0.29+/-0.08 min, respectively, P=0.0001). Distribution of the carbon in man followed the same pattern as in a previous reported study in animals. The carbon deposited uniformly along the lid margin in the case of the PFD vehicle, whereas it agglomerated following dosing in the saline vehicle and was ejected from the eye. The novel non-aqueous vehicle system is able to significantly improve the ocular retention of charcoal particles in man and provides a unique distribution of the particles in the eye, which suggests a potential for the PFD system for the treatment of periocular diseases.

  20. Ocular Toxicity Testing of Lunar Dust

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie E.

    2010-01-01

    This slide presentation reviews the use of ocular testing to determine the toxicity of lunar dust. The OECD recommendations are reviewed. With these recommendations in mind the test methodology was to use EpiOcular, tissues derived from normal human epidermal keratinocytes, the cells of which have been differentiated on cell culture inserts to form a multi-layered structure, which closely parallels the corneal epithelium and to dose the tissue with 100 mg dust from various sources. The in-vitro study provides evidence that lunar dust is not severely corrosive or irritating, however, in vitro tests have limitations, and in vivo tests provides a more complete scenario, and information, it is recommended that in vivo tests be performed.

  1. Irritable eye syndrome: neuroimmune mechanisms and benefits of selected nutrients.

    PubMed

    Feher, Janos; Pinter, Erika; Kovács, Illés; Helyes, Zsuzsanna; Kemény, Agnes; Markovics, Adrienn; Plateroti, Rocco; Librando, Aloisa; Cruciani, Filippo

    2014-04-01

    Previous studies showed comorbidity of some ocular, enteral, and affective symptoms comprising irritable eye syndrome. Aims of the present study were to learn more about the pathogenic mechanisms of this syndrome and to evaluate benefits of food supplements on these disorders. In in vitro assay, Lactobacillus acidophilus lysate inhibited interleukin (IL)-1β and tumor necrosis factor (TNF)-α generation of lipopolysaccharide (LPS)-stimulated macrophages in dose- and size-dependent manner. For a prospective, open-label phase I/II controlled clinical trial, 40 subjects affected by ocular dysesthesia and hyperesthesia and comorbid enteral and anxiety-depression symptoms were randomly assigned either into the treated group, which received a composition containing probiotic lysate, vitamins A, B, and D and omega 3 fatty acids, or into the control group, which received vitamins and omega 3 fatty acids. For reference, 20 age- and sex-matched healthy subjects were also selected. White blood count (WBC) and lymphocyte and monocyte counts, as well as IL-6 and TNF-α levels, were significantly above the reference levels in both treated and control groups. After 8 weeks, WBC and lymphocyte and monocyte counts, and cytokine levels significantly decreased, and ocular, enteral, and anxiety-depression symptoms significantly improved in the treated group as compared to the control group. This proof-of-concept study suggested that subclinical inflammation may be a common mechanism connecting ocular, enteral, and anxiety/depression symptoms, and supplements affecting dysbiosis may be a new approach to treating this syndrome. Copyright © 2014. Published by Elsevier Inc.

  2. Formulation and evaluation of voriconazole ophthalmic solid lipid nanoparticles in situ gel.

    PubMed

    Pandurangan, Dinesh Kumar; Bodagala, Prathima; Palanirajan, Vijayaraj Kumar; Govindaraj, Saravanan

    2016-01-01

    In the present investigation, solid lipid nanoparticles (SLNs)-loaded in situ gel with voriconazole drug was formulated. Further, the formulation was characterized for pH, gelling capacity, entrapment efficiency, in vitro drug release, drug content, and viscosity. Voriconazole is an antifungal drug used to treat various infections caused by yeast or other types of fungi. Film hydration technique was used to prepared SLNs from lecithin and cholesterol. Based on the entrapment efficiency 67.2-97.3% and drug release, the optimized formulation NF1 of SLNs was incorporated into in situ gels. The in situ gels were prepared using viscosity-enhancing polymers such as Carbopol and (hydroxypropyl)methyl cellulose (HPMC). Formulated SLN in situ gel formulations were characterized, which showed pH 4.9-7.1, drug content 65.69-96.3%, and viscosity (100 rpm) 120-620 cps. From the characterizations given above, F6 was optimized and evaluated for microbial assay and ocular irritation studies. Microbial assay was conducted by the cup-plate method using Candida albicans as the test organism. An ocular irritation study was conducted on albino rabbits. The results revealed that there was no ocular damage to the cornea, conjunctiva, or iris. Stability studies were carried out on the F6 formulation for 3 months, which showed that the formulation had good stability. These results indicate that the studied SLNs-loaded in situ gel is a promising vehicle for ocular delivery.

  3. [Effect of anti-inflammatory therapy on the treatment of dry eye syndrome].

    PubMed

    Mrukwa-Kominek, Ewa; Rogowska-Godela, Anna; Gierek-Ciaciura, Stanisława

    2007-01-01

    Dry eye syndrome is a common chronic disease; agents and strategies for its effective management are still lacking. The syndrome tends to be accompanied by ocular surface inflammation; therefore, the use of anti-inflammatory agents might prove beneficial. The authors present up-to-date guidelines, strategies, and efficacy of dry eye syndrome management, including anti-inflammatory treatment. As no diagnostic tests are now available to assess ocular surface inflammation severity, the right timing to launch an anti-inflammatory agent is difficult to determine. Patients with mild intermittent bouts of symptoms which can be alleviated with ophthalmic lubricants do not typically require anti-inflammatory therapy. The latter should be considered in those who do not respond to lubricating drops, obtain poor results on clinical tests, and show symptoms of ocular surface irritation (eg. conjunctivae redness). Anti-inflammatory treatment of dry eye syndrome may include short-term corticosteroids, cyclosporine A emulsion, oral tetracycline therapy, oral omega-3 fatty acid supplements, and autologous serum eye drops. Anti-inflammatory treatment should be safe and effective; potential benefits should be evaluated for each individual patient. The authors have reviewed the advantages of anti-inflammatory treatment in dry eye syndrome, presented in literature.

  4. 40 CFR 721.1930 - Butanoic acid, antimony (3=) salt.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subject to reporting. (1) The chemical substance identified as butanoic acid, antimony (3=) salt (PMN P-94... following statement: This substance may cause neurologic effects. This substance may cause cardiovascular effects. This substance may cause ocular irritation. (iii) Industrial, commercial, and consumer activities...

  5. 40 CFR 721.1930 - Butanoic acid, antimony (3=) salt.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subject to reporting. (1) The chemical substance identified as butanoic acid, antimony (3=) salt (PMN P-94... following statement: This substance may cause neurologic effects. This substance may cause cardiovascular effects. This substance may cause ocular irritation. (iii) Industrial, commercial, and consumer activities...

  6. 40 CFR 721.1930 - Butanoic acid, antimony (3=) salt.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subject to reporting. (1) The chemical substance identified as butanoic acid, antimony (3=) salt (PMN P-94... following statement: This substance may cause neurologic effects. This substance may cause cardiovascular effects. This substance may cause ocular irritation. (iii) Industrial, commercial, and consumer activities...

  7. 40 CFR 721.1930 - Butanoic acid, antimony (3=) salt.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subject to reporting. (1) The chemical substance identified as butanoic acid, antimony (3=) salt (PMN P-94... following statement: This substance may cause neurologic effects. This substance may cause cardiovascular effects. This substance may cause ocular irritation. (iii) Industrial, commercial, and consumer activities...

  8. Ocular Toxicity Secondary to Asclepias physocarpa: The Balloon Plant

    PubMed Central

    Pina, Susana; Pedrosa, Catarina; Santos, Cristina; Feijóo, Bernardo; Pego, Peter; Vendrell, Cristina; Santos, Maria João; Prieto, Isabel

    2014-01-01

    We report a case of a 65-year-old woman with symptoms of blurred vision and ocular irritation a few hours after accidental contact of the right eye with Asclepias physocarpa milky latex. Observation showed a diffuse conjunctival hyperemia and stromal corneal edema with Descemet's membrane folds. Recovery was fast and apparently complete in less than one month. However, specular microscopy at 6-months follow-up showed an abnormal endothelial morphology as sequelae, suggesting this condition is not as innocuous as it has been suggested. PMID:25105044

  9. Safety and efficacy of personal care products containing colloidal oatmeal.

    PubMed

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period.

  10. Safety and efficacy of personal care products containing colloidal oatmeal

    PubMed Central

    Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane

    2012-01-01

    Background Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. Methods In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. Results We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Conclusion Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period. PMID:23204849

  11. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    PubMed

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  12. Safety assessment and toxicological profiling of a novel combinational sunprotective dermal formulation containing melatonin and pumpkin seed oil.

    PubMed

    Bora, Nilutpal Sharma; Pathak, Manash Pratim; Mandal, Santa; Mazumder, Bhaskar; Policegoudra, Rudragoud; Raju, Pakalapati Srinivas; Chattopadhyay, Pronobesh

    2017-10-01

    Ultraviolet (UV) radiation exposure has been known to cause irreparable damages to human skin. The daunting risk of UV radiation exposure faced by military personnel led to the development of a sunscreen formulation which has superior sun protection factor combined with the ability to counteract reactive oxygen species. The present work deals with the preclinical safety evaluation of the sunscreen formulation comprising of four US FDA approved UV filters; namely avobenzone, octinoxate, oxybenzone, titanium dioxide along with melatonin and pumpkin seed oil, via OECD protocols of assessing acute oral and dermal toxicity; skin sensitizing; skin irritating; ocular irritating and genotoxic potential. Both oral and dermal LD 50 values were found to be ˃2000 mg/kg body weight in adult Wistar albino rats using acute dermal and oral toxicity tests. The sunscreen formulation was found to be non-sensitizing to the skin of guinea pigs and non-irritating to both skin and eyes of rabbits. The sunscreen formulation was also found to be non-mutagenic which was affirmed by a battery of genotoxicity and muagenicity assays. The results obtained from this preclinical study indicated that the sunscreen formulation is non toxic and safe in animal models. This study along with additional preclinical evaluations may serve as a basis for considering the formulation as a potential candidate for further trials to establish its efficacy, tolerability and applicability. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Transient receptor potential ankyrin 1 antagonists block the noxious effects of toxic industrial isocyanates and tear gases.

    PubMed

    Bessac, Bret F; Sivula, Michael; von Hehn, Christian A; Caceres, Ana I; Escalera, Jasmine; Jordt, Sven-Eric

    2009-04-01

    The release of methyl isocyanate in Bhopal, India, caused the worst industrial accident in history. Exposures to industrial isocyanates induce lacrimation, pain, airway irritation, and edema. Similar responses are elicited by chemicals used as tear gases. Despite frequent exposures, the biological targets of isocyanates and tear gases in vivo have not been identified, precluding the development of effective countermeasures. We use Ca(2+) imaging and electrophysiology to show that the noxious effects of isocyanates and those of all major tear gas agents are caused by activation of Ca(2+) influx and membrane currents in mustard oil-sensitive sensory neurons. These responses are mediated by transient receptor potential ankyrin 1 (TRPA1), an ion channel serving as a detector for reactive chemicals. In mice, genetic ablation or pharmacological inhibition of TRPA1 dramatically reduces isocyanate- and tear gas-induced nocifensive behavior after both ocular and cutaneous exposures. We conclude that isocyanates and tear gas agents target the same neuronal receptor, TRPA1. Treatment with TRPA1 antagonists may prevent and alleviate chemical irritation of the eyes, skin, and airways and reduce the adverse health effects of exposures to a wide range of toxic noxious chemicals.

  14. Air bags and the skin.

    PubMed

    Corazza, Monica; Trincone, Silvana; Zampino, Maria Rosaria; Virgili, Annarosa

    2004-01-01

    Air bags, fitted in the majority of new automobiles, are safety devices activated when a sudden deceleration causes the ignition of a propellant cartridge containing sodium azide. The bag is inflated by nitrogen liberated during the combustion. Deployment releases various high-temperature gases, including nitrogen and carbon dioxide, and produces sodium hydroxide, a highly irritant alkaline substance. In about 7%-8% of cases, air bags cause dermatologic injuries such as traumatic lesions, irritant dermatitis, and chemical and thermal burns. Nondermatologic lesions, such as ocular damage (alkali keratitis, corneal abrasions), ear lesions, bone fractures, and contusive damage can also be caused by air bag deployment.

  15. Limitations of an ocular surface inflammatory biomarker in impression cytology specimens.

    PubMed

    Yafawi, Rolla; Ko, Mira; Sace, Frederick P; John-Baptiste, Annette

    2013-03-01

    A number of ocular conditions, such as dry eye, are associated with inflammation on the surface of the eye leading to irritation and ocular pain. Many drugs such as chemotherapeutics, beta blockers, angiotensin-converting enzymes and so forth also cause dry eye but currently there are no validated ocular surface biomarkers available. We evaluated sample stability, assay sensitivity, reproducibility and overall performance of impression cytology (IC) utilizing the cellular surface biomarker human leukocyte antigen DR-1 (HLA-DR) as an ocular surface inflammatory biomarker by flow cytometry in a fit-for-purpose validation study. Additionally, subjects classified as normal or having various degrees of dry eye were evaluated to determine if HLA-DR could demonstrate a clear separation between normal and dry eye samples. The assay demonstrated high dynamic range detecting a broad range of fluorescent intensities in healthy donors. Additionally, inter, intra and stability assay results demonstrated strong concordance and low variability. Overall CV% for both assays were less than 25% for all measured parameters. However, high variability was observed for donor samples assayed beyond day 10 post IC sample collection (4.2-110.8 CV%). HLA-DR expression demonstrated a progressive increase in patients with mild to severe levels of dry eye disease providing sufficient evidence it is sensitive enough to monitor inflammatory effects of dry eye when coupled with additional biomarkers and/or methodologies such as cytokine analysis or ICAM-1. This biomarker can be used to monitor ocular surface disorders in patients and to evaluate potential treatment options during drug development. Although our results demonstrate this methodology is reproducible for routine evaluation, limitations around sample integrity exist. The ocular cell surface inflammatory biomarker, HLA-DR coupled with impression cytology is a simple non-invasive robust, specific and reproducible assay that can be utilized to measure inflammatory infiltrates on the surface of the eye in IC samples less than 10-days old.

  16. Amended final report of the safety assessment of dibutyl adipate as used in cosmetics.

    PubMed

    Andersen, Alan

    2006-01-01

    Dibutyl Adipate, the diester of butyl alcohol and adipic acid, functions as a plasticizer, skin-conditioning agent, and solvent in cosmetic formulations. It is reportedly used at a concentration of 5% in nail polish and 8% in suntan gels, creams, and liquids. Dibutyl Adipate is soluble in organic solvents, but practically insoluble in water. Dibutyl Adipate does not absorb radiation in the ultraviolet (UV) region of the spectrum. Dibutyl Adipate is not toxic in acute oral or dermal animal toxicity tests. In a subchronic dermal toxicity study, 1.0 ml/kg day-1 caused a significant reduction in body weight gain in rabbits, but 0.5 ml/kg/day1 was without effect. In a study with dogs, no adverse effects were observed when an emulsion containing 6.25% Dibutyl Adipate was applied to the entire body twice a week for 3 months. Dibutyl Adipate was tested for dermal irritation using rabbits and mice and a none to minimal irritation was observed. Dibutyl Adipate at a concentration of 25% was not a sensitizer in a guinea pig maximization study. Undiluted Dibutyl Adipate was minimally irritating to the eyes of rabbits and 0.1% was nonirritating. A significant increase in fetal gross abnormalities was observed in rats given intraperitoneal injections of Dibutyl Adipate at 1.75 ml/kg on 3 separate days during gestation, but no effect was seen in animals given 1.05 ml/kg. Dibutyl Adipate was not genotoxic in either bacterial or mammalian test systems. Clinical patch tests confirmed the absence of skin irritation found in animal tests. Clinical phototoxicity tests were negative. Dibutyl Adipate at 0.1% was not an ocular irritant in two male volunteers. In a clinical test of comedogenicity, Dibutyl Adipate produced no effect. The Cosmetic Ingredient Review (CIR) Expert Panel recognized that use of Dibutyl Adipate in suntan cosmetic products will result in repeated, frequent exposure in a leave-on product. The available data demonstrate no skin sensitization or cumulative skin irritation, no comedogenicity, and no genotoxicity. Combined with the data demonstrating little acute toxicity, no skin or ocular irritation, and no reproductive or developmental toxicity, these data form an adequate basis for reaching a conclusion that Dibutyl Adipate is safe as a cosmetic ingredient in the practices of use and concentrations as reflected in this safety assessment.

  17. Inflammation in dry eye.

    PubMed

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  18. Developing a quick and inexpensive in vitro (non-animal) bioassay for mascara irritation.

    PubMed

    Thomason, H; Montagnes, D J S

    2014-04-01

    Mascara is a mild irritant that causes a range of medical problems. Animal models to predict ocular irritation have, however, been questioned at a number of levels, and there is a continued need to develop in vitro testing methods. We assess changes in an easily quantifiable attribute, ciliated protozoan growth rate, as a sensitive, sublethal measure. Specifically, we test six, randomly chosen, commercial mascara products against a control (as treatments) and reveal through ANOVA (n = 6, α = 0.05) significant differences in the specific growth rate to treatments (for both protozoa). We provide evidence that two easily cultured protozoa (Paramecium caudatum, Blepharisma japonicum) should be considered as models to assess ocular irritancy (and possibly cosmetics in general) and establish the groundwork for such studies to be applied at a more commercial level. We do this by developing a bioassay for mascara toxicity and indicate the low cost (after equipment is purchased, on the order of $100s) and the ease of performing such tests (able to be conducted by undergraduate students), as a consideration for their future commercial application. We first examined dose dependence of responses, revealing that there was a need to conduct preliminary work to determine appropriate levels for sublethal responses. We then show that some products resulted in mortality at high concentrations, others decreased growth rate by >50% (compared with the control), whereas others had no significant effect, compared with the control. We have provided a novel, quick and inexpensive means to assess mascara; the next step is to validate these ciliate bioassays by comparison with animal testing and epidemiological studies, which is beyond the scope of this fundamental 'proof-of-concept' study. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  19. Efficacy of a crosslinked hyaluronic acid-based hydrogel as a tear film supplement: a masked controlled study.

    PubMed

    Williams, David L; Mann, Brenda K

    2014-01-01

    Keratoconjunctivitis sicca (KCS), or dry eye, is a significant medical problem in both humans and dogs. Treating KCS often requires the daily application of more than one type of eye drop in order to both stimulate tear prodcution and provide a tear supplement to increase hydration and lubrication. A previous study demonstrated the potential for a crosslinked hyaluronic acid-based hydrogel (xCMHA-S) to reduce the clinical signs associated with KCS in dogs while using a reduced dosing regimen of only twice-daily administration. The present study extended those results by comparing the use of the xCMHA-S to a standard HA-containing tear supplement in a masked, randomized clinical study in dogs with a clinical diagnosis of KCS. The xCMHA-S was found to significantly improve ocular surface health (conjunctival hyperaemia, ocular irritation, and ocular discharge) to a greater degree than the alternative tear supplement (P = 0.0003). Further, owners reported the xCMHA-S treatment as being more highly effective than the alternative tear supplement (P = 0.0024). These results further demonstrate the efficacy of the xCMHA-S in reducing the clinical signs associated with KCS, thereby improving patient health and owner happiness.

  20. 16 CFR 1500.42 - Test for eye irritants.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... noted below. (2) The eyes are examined and the grade of ocular reaction is recorded at 24, 48, and 72 hours. Reading of reactions is facilitated by use of a binocular loupe, hand slit-lamp, or other expert... positive reaction if the test substance produces at any of the readings ulceration of the cornea (other...

  1. Computer vision syndrome: a review.

    PubMed

    Blehm, Clayton; Vishnu, Seema; Khattak, Ashbala; Mitra, Shrabanee; Yee, Richard W

    2005-01-01

    As computers become part of our everyday life, more and more people are experiencing a variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation, redness, blurred vision, and double vision, collectively referred to as computer vision syndrome. This article describes both the characteristics and treatment modalities that are available at this time. Computer vision syndrome symptoms may be the cause of ocular (ocular-surface abnormalities or accommodative spasms) and/or extraocular (ergonomic) etiologies. However, the major contributor to computer vision syndrome symptoms by far appears to be dry eye. The visual effects of various display characteristics such as lighting, glare, display quality, refresh rates, and radiation are also discussed. Treatment requires a multidirectional approach combining ocular therapy with adjustment of the workstation. Proper lighting, anti-glare filters, ergonomic positioning of computer monitor and regular work breaks may help improve visual comfort. Lubricating eye drops and special computer glasses help relieve ocular surface-related symptoms. More work needs to be done to specifically define the processes that cause computer vision syndrome and to develop and improve effective treatments that successfully address these causes.

  2. New nanomicelle curcumin formulation for ocular delivery: improved stability, solubility, and ocular anti-inflammatory treatment.

    PubMed

    Li, Mengshuang; Xin, Meng; Guo, Chuanlong; Lin, Guiming; Wu, Xianggen

    2017-11-01

    A stable topical ophthalmic curcumin formulation with high solubility, stability, and efficacy is needed for pharmaceutical use in clinics. The objective of this article was to describe a novel curcumin containing a nanomicelle formulation using a polyvinyl caprolactam-polyvinyl acetate-polyethylene glycol (PVCL-PVA-PEG) graft copolymer. Nanomicelle curcumin was formulated and optimized and then further evaluated for in vitro cytotoxicity/in vivo ocular irritation, in vitro cellular uptake/in vivo corneal permeation, and in vitro antioxidant activity/in vivo anti-inflammatory efficacy. The solubility, chemical stability, and antioxidant activity were greatly improved after the encapsulation of the PVCL-PVA-PEG nanomicelles. The nanomicelle curcumin ophthalmic solution was simple to prepare and the nanomicelles are stable to the storage conditions, and it had good cellular tolerance. Nanomicelle curcumin also had excellent ocular tolerance in rabbits. The use of nanomicelles significantly improved in vitro cellular uptake and in vivo corneal permeation as well as improved anti-inflammatory efficacy when compared with a free curcumin solution. These findings indicate that nanomicelles could be promising topical delivery systems for the ocular administration of curcumin.

  3. Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.

    PubMed

    Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K

    2010-02-01

    Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.

  4. Dry Eye Disease: Prevalence, Assessment, and Management.

    PubMed

    Rouen, Patricia A; White, Mary L

    Dry eye disease is a chronic condition of the corneal surface marked by persistent symptoms of irritation or burning that can cause inflammatory damage to the cornea and conjunctiva if untreated. Common risk factors for this syndrome include advancing age, female sex, low humidity environments, systemic medications, and autoimmune disorders. Treatments to relieve symptoms include tear replacement, humidification, improved nutrition, and anti-inflammatory ocular agents. Home healthcare nurses can identify signs and symptoms of dry eye syndrome and initiate strategies that range from warm compresses to physician referrals for more aggressive treatment. Consistent management of this condition improves quality of life and minimizes damage to the ocular surface.

  5. Ocular drug delivery systems: An overview

    PubMed Central

    Patel, Ashaben; Cholkar, Kishore; Agrahari, Vibhuti; Mitra, Ashim K

    2014-01-01

    The major challenge faced by today’s pharmacologist and formulation scientist is ocular drug delivery. Topical eye drop is the most convenient and patient compliant route of drug administration, especially for the treatment of anterior segment diseases. Delivery of drugs to the targeted ocular tissues is restricted by various precorneal, dynamic and static ocular barriers. Also, therapeutic drug levels are not maintained for longer duration in target tissues. In the past two decades, ocular drug delivery research acceleratedly advanced towards developing a novel, safe and patient compliant formulation and drug delivery devices/techniques, which may surpass these barriers and maintain drug levels in tissues. Anterior segment drug delivery advances are witnessed by modulation of conventional topical solutions with permeation and viscosity enhancers. Also, it includes development of conventional topical formulations such as suspensions, emulsions and ointments. Various nanoformulations have also been introduced for anterior segment ocular drug delivery. On the other hand, for posterior ocular delivery, research has been immensely focused towards development of drug releasing devices and nanoformulations for treating chronic vitreoretinal diseases. These novel devices and/or formulations may help to surpass ocular barriers and associated side effects with conventional topical drops. Also, these novel devices and/or formulations are easy to formulate, no/negligibly irritating, possess high precorneal residence time, sustain the drug release, and enhance ocular bioavailability of therapeutics. An update of current research advancement in ocular drug delivery necessitates and helps drug delivery scientists to modulate their think process and develop novel and safe drug delivery strategies. Current review intends to summarize the existing conventional formulations for ocular delivery and their advancements followed by current nanotechnology based formulation developments. Also, recent developments with other ocular drug delivery strategies employing in situ gels, implants, contact lens and microneedles have been discussed. PMID:25590022

  6. Ocular drug delivery systems: An overview.

    PubMed

    Patel, Ashaben; Cholkar, Kishore; Agrahari, Vibhuti; Mitra, Ashim K

    The major challenge faced by today's pharmacologist and formulation scientist is ocular drug delivery. Topical eye drop is the most convenient and patient compliant route of drug administration, especially for the treatment of anterior segment diseases. Delivery of drugs to the targeted ocular tissues is restricted by various precorneal, dynamic and static ocular barriers. Also, therapeutic drug levels are not maintained for longer duration in target tissues. In the past two decades, ocular drug delivery research acceleratedly advanced towards developing a novel, safe and patient compliant formulation and drug delivery devices/techniques, which may surpass these barriers and maintain drug levels in tissues. Anterior segment drug delivery advances are witnessed by modulation of conventional topical solutions with permeation and viscosity enhancers. Also, it includes development of conventional topical formulations such as suspensions, emulsions and ointments. Various nanoformulations have also been introduced for anterior segment ocular drug delivery. On the other hand, for posterior ocular delivery, research has been immensely focused towards development of drug releasing devices and nanoformulations for treating chronic vitreoretinal diseases. These novel devices and/or formulations may help to surpass ocular barriers and associated side effects with conventional topical drops. Also, these novel devices and/or formulations are easy to formulate, no/negligibly irritating, possess high precorneal residence time, sustain the drug release, and enhance ocular bioavailability of therapeutics. An update of current research advancement in ocular drug delivery necessitates and helps drug delivery scientists to modulate their think process and develop novel and safe drug delivery strategies. Current review intends to summarize the existing conventional formulations for ocular delivery and their advancements followed by current nanotechnology based formulation developments. Also, recent developments with other ocular drug delivery strategies employing in situ gels, implants, contact lens and microneedles have been discussed.

  7. Exposure of eyes to perfume: a double-blind, placebo-controlled experiment.

    PubMed

    Elberling, J; Duus Johansen, J; Dirksen, A; Mosbech, H

    2006-08-01

    Environmental perfume exposure can elicit bothersome respiratory symptoms. Symptoms are induced at exposure levels which most people find tolerable, and the mechanisms are unclear. The aim of the study was to investigate patients with eye and respiratory symptoms related to environmental perfume, by exposing the eyes to perfume in a double-blind, placebo-controlled study.Twenty-one eczema patients with respiratory symptoms elicited by perfume were compared with 21 healthy volunteers in a sex- and age-matched case-control study. The participants completed a symptom questionnaire, and underwent a double-blind, placebo-controlled exposure to perfume. Of the 42 individuals tested, 10 had more eye symptoms (irritation, itching, and tears) during perfume exposure than during placebo exposures, and eight of these individuals (P = 0.07, Fisher's exact test) belonged to the patient group. A true positive eye reaction to perfume was significantly associated with identification of perfume as an active exposure (P < 0.05). In this study, vapor of perfume elicited irritation in the eyes independently of olfaction, but the relative importance of ocular chemoperception in relation to elicitation of respiratory symptoms from common environmental exposures to perfume remains unclear. We investigated the hypothesis of an association between respiratory symptoms related to perfume and ocular perfume sensitivity by exposing the eyes to perfume in a double blind, placebo-controlled experiment. Vapors of perfume provoked symptoms in the relevant eye in some patients and healthy control persons, but under our exposure conditions, ocular chemesthesis failed to elicit respiratory symptoms.

  8. Cytoprotective effect against UV-induced DNA damage and oxidative stress: role of new biological UV filter.

    PubMed

    Said, T; Dutot, M; Martin, C; Beaudeux, J-L; Boucher, C; Enee, E; Baudouin, C; Warnet, J-M; Rat, P

    2007-03-01

    The majority of chemical solar filters are cytotoxic, particularly on sensitive ocular cells (corneal and conjunctival cells). Consequently, a non-cytotoxic UV filter would be interesting in dermatology, but more especially in ophthalmology. In fact, light damage to the eye can be avoided thanks to a very efficient ocular antioxidant system; indeed, the chromophores absorb light and dissipate its energy. After middle age, a decrease in the production of antioxidants and antioxidative enzymes appears with accumulation of endogenous molecules that are phototoxic. UV radiations can induce reactive oxygen species formation, leading to various ocular diseases. Because most UV filters are cytotoxic for the eye, we investigated the anti-UV properties of Calophyllum inophyllum oil in order to propose it as a potential vehicle, free of toxicity, with a natural UV filter action in ophthalmic formulation. Calophyllum inophyllum oil, even at low concentration (1/10,000, v/v), exhibited significant UV absorption properties (maximum at 300nm) and was associated with an important sun protection factor (18-22). Oil concentrations up to 1% were not cytotoxic on human conjunctival epithelial cells, and Calophyllum inophyllum oil appeared to act as a cytoprotective agent against oxidative stress and DNA damage (85% of the DNA damage induced by UV radiations were inhibited with 1% Calophyllum oil) and did not induce in vivo ocular irritation (Draize test on New Zealand rabbits). Calophyllum inophyllum oil thus exhibited antioxidant and cytoprotective properties, and therefore might serve, for the first time, as a natural UV filter in ophthalmic preparations.

  9. Chitosan-based thermosensitive hydrogel as a promising ocular drug delivery system: preparation, characterization, and in vivo evaluation.

    PubMed

    Chen, Xingwei; Li, Xinru; Zhou, Yanxia; Wang, Xiaoning; Zhang, Yanhui; Fan, Yating; Huang, Yanqing; Liu, Yan

    2012-11-01

    The purpose of this study was to evaluate the feasibility of in situ thermosensitive hydrogel based on chitosan in combination with disodium α-d-Glucose 1-phosphate (DGP) for ocular drug delivery system. Aqueous solution of chitosan/DGP underwent sol-gel transition as temperature increased which was flowing sol at room temperature and then turned into non-flowing hydrogel at physiological temperature. The properties of gels were characterized regarding gelation time, gelation temperature, and morphology. The sol-to-gel phase transition behaviors were affected by the concentrations of chitosan, DGP and the model drug levocetirizine dihydrochloride (LD). The developed hydrogel presented a characteristic of a rapid release at the initial period followed by a sustained release and remarkably enhanced the cornea penetration of LD. The results of ocular irritation demonstrated the excellent ocular tolerance of the hydrogel. The ocular residence time for the hydrogel was significantly prolonged compared with eye drops. The drug-loaded hydrogel produced more effective anti-allergic conjunctivitis effects compared with LD aqueous solution. These results showed that the chitosan/DGP thermosensitive hydrogel could be used as an ideal ocular drug delivery system in terms of the suitable sol-gel transition temperature, mild pH environment in the hydrogel as well as the organic solvent free.

  10. Biopharmaceutical profile of pranoprofen-loaded PLGA nanoparticles containing hydrogels for ocular administration.

    PubMed

    Abrego, Guadalupe; Alvarado, Helen; Souto, Eliana B; Guevara, Bessy; Bellowa, Lyda Halbaut; Parra, Alexander; Calpena, Ana; Garcia, María Luisa

    2015-09-01

    Two optimized pranoprofen-loaded poly-l-lactic-co glycolic acid (PLGA) nanoparticles (PF-F1NPs; PF-F2NPs) have been developed and further dispersed into hydrogels for the production of semi-solid formulations intended for ocular administration. The optimized PF-NP suspensions were dispersed in freshly prepared carbomer hydrogels (HG_PF-F1NPs and HG_PF-F2NPs) or in hydrogels containing 1% azone (HG_PF-F1NPs-Azone and HG_PF-F2NPs-Azone) in order to improve the ocular biopharmaceutical profile of the selected non-steroidal anti-inflammatory drug (NSAID), by prolonging the contact of the pranoprofen with the eye, increasing the drug retention in the organ and enhancing its anti-inflammatory and analgesic efficiency. Carbomer 934 has been selected as gel-forming polymer. The hydrogel formulations with or without azone showed a non-Newtonian behavior and adequate physicochemical properties for ocular instillation. The release study of pranoprofen from the semi-solid formulations exhibited a sustained release behavior. The results obtained from ex vivo corneal permeation and in vivo anti-inflammatory efficacy studies suggest that the ocular application of the hydrogels containing azone was more effective over the azone-free formulations in the treatment of edema on the ocular surface. No signs of ocular irritancy have been detected for the produced hydrogels. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Development of loteprednol etabonate-loaded cationic nanoemulsified in-situ ophthalmic gel for sustained delivery and enhanced ocular bioavailability.

    PubMed

    Patel, Nirav; Nakrani, Happy; Raval, Mihir; Sheth, Navin

    2016-11-01

    A novel cationic nanoemulsified in-situ ophthalmic gel of loteprednol etabonate (LE) was developed to improve the permeability and retention time of formulations for overall improvement of drug's ocular bioavability. Capryol 90 (oil phase), tween 80 (surfactant) and transcutol P (cosurfactant) was selected as formulation excipients to construct pseudoternary phase diagrams and nanoemulsion region was recognized from diagrams. Spontaneous emulsification method was used to manufacture LE nanoemulsion and it was optimized using 3 2 factorial design by considering the amount of oil and the ratio of surfactant to cosurfactant (S mix ) as independent variables and evaluated for various physicochemical properties. Optimized NE was dispersed in Poloxamer 407 and 188 solution to form nanoemulsified sols that were predictable to transform into in-situ gels at corneal temperature. Drug pharmacokinetics of sterilized optimized in situ NE gel, NE-ISG2 [0.69% w/w Capryol 90, 0.99%w/w S mix (3:1), 13% Poloxamer 407, 4% w/w Poloxamer 188] and marketed formulation were assessed in rabbit aqueous humor. The in-situ gels were clear, shear thinning in nature and displayed zero-order drug release kinetics. NE-ISG2 showed the minimum ocular irritation potential and significantly (p < 0.01) higher C max and AUC (0-10 h) , delayed T max , extended mean residence time and improved (2.54-fold times) bioavailability compared to marketed formulation.

  12. The Ex vivo Eye Irritation Test (EVEIT) model as a mean of improving venom ophthalmia understanding.

    PubMed

    Delafontaine, Marie; Panfil, Claudia; Spöler, Felix; Kray, Stefan; Burgher, François; Mathieu, Laurence; Blomet, Joël; Schrage, Norbert F; Tambourgi, Denise V

    2018-06-08

    Snakes belonging to the genus Naja (Elapid family), also known as "spitting cobras", can spit venom towards the eyes of the predator as a defensive strategy, causing painful and potentially blinding ocular envenoming. Venom ophthalmia is characterized by pain, hyperemia, blepharitis, blepharospasm and corneal erosions. Elapid venom ophthalmia is not well documented and no specific treatment exists. Furthermore, accidental ejection of venom by non-spitting vipers, as Bothrops, also occurs. The Ex vivo Eye Irritation Test model (EVEIT) has enabled important progress in the knowledge of chemical ocular burns. Considering the lack of experimental animal model, we adapted the EVEIT to study venom ophthalmia mechanisms. Ex vivo rabbit corneas were exposed to venoms from spitting (Naja mossambica, Naja nigricollis) and non-spitting (Naja naja, Bothrops jararaca and Bothrops lanceolatus) snakes, and rinsed or not with water. The corneal thickness and the depth of damage were assessed using high-resolution optical coherence tomography (HR-OCT) imaging and histological analysis. All Naja venoms induced significant corneal edema, collagen structure disorganization and epithelial necrosis. Corneas envenomed by African N. mossambica and N. nigricollis venoms were completely opaque. Opacification was not observed in corneas treated with venoms from non-spitting snakes, such as the Asian cobra, N. naja, and the vipers, B. jararaca and B. lanceolatus. Moreover, Bothrops venoms were able to damage the epithelium and cause collagen structure disorganization, but not edema. Immediate water rinsing improved corneal status, though damage and edema could still be observed. In conclusion, the present study shows that the EVEIT model was successfully adapted to set a new experimental ex vivo animal model of ophthalmia, caused by snake venoms, which will enable to explore new therapies for venom ophthalmia. Copyright © 2018. Published by Elsevier Ltd.

  13. Therapeutic inhibitors for the treatment of dry eye syndrome.

    PubMed

    Rodríguez-Pomar, Candela; Pintor, Jesus; Colligris, Basilio; Carracedo, Gonzalo

    2017-12-01

    Dry eye disease (DED), defined as a multifactorial disease of tears and ocular surface, results in symptoms of discomfort, ocular irritation, visual disturbance and tear film instability. This syndrome is accompanied of ocular surface inflammation and it is produced by a deficient activity of the lacrimal functional unit. In addition, it is associated with systemic autoimmune diseases such as Sjögren´s Syndrome, rheumatoid arthritis, systemic lupus erythematosus and some drug administration. The treatment of dry eye disease is based on the typical signs and symptoms of dry eye, which are associated with hyperosmolarity, ocular surface inflammation, discomfort, visual disturbance, and tear film instability. Areas covered: This review is focused on synthetic drugs currently used in clinical practice, from phase III development onwards to treat the ocular surface signs and symptoms of dry eye disease. Expert opinion: The multifactorial disease and the lack of correlation between signs and symptoms imply that not all the pharmacological approaches will be successful for dry eye. The correct design of the clinical trials, with appropriate endpoints, and the type of dry eye under study are complicated but mandatory. The anti-inflammatory and secretagogues drugs are both the main compounds to currently treat the dry eye disease.

  14. Alternatives to In Vivo Draize Rabbit Eye and Skin Irritation Tests with a Focus on 3D Reconstructed Human Cornea-Like Epithelium and Epidermis Models

    PubMed Central

    Lee, Miri; Hwang, Jee-Hyun; Lim, Kyung-Min

    2017-01-01

    Human eyes and skin are frequently exposed to chemicals accidentally or on purpose due to their external location. Therefore, chemicals are required to undergo the evaluation of the ocular and dermal irritancy for their safe handling and use before release into the market. Draize rabbit eye and skin irritation test developed in 1944, has been a gold standard test which was enlisted as OECD TG 404 and OECD TG 405 but it has been criticized with respect to animal welfare due to invasive and cruel procedure. To replace it, diverse alternatives have been developed: (i) For Draize eye irritation test, organotypic assay, in vitro cytotoxicity-based method, in chemico tests, in silico prediction model, and 3D reconstructed human cornea-like epithelium (RhCE); (ii) For Draize skin irritation test, in vitro cytotoxicity-based cell model, and 3D reconstructed human epidermis models (RhE). Of these, RhCE and RhE models are getting spotlight as a promising alternative with a wide applicability domain covering cosmetics and personal care products. In this review, we overviewed the current alternatives to Draize test with a focus on 3D human epithelium models to provide an insight into advancing and widening their utility. PMID:28744350

  15. Discharge and infection in retinoblastoma post-enucleation sockets

    PubMed Central

    Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C

    2017-01-01

    Purpose To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). Methods A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients’ characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. Results A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients (P<0.001). Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Conclusion Ocular prosthesis-wearing patients often experienced mucoid discharge, and less often irritation and socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which local antibiotic treatment seemed effective in most cases. PMID:28280296

  16. Discharge and infection in retinoblastoma post-enucleation sockets.

    PubMed

    Mourits, Daphne L; Hartong, Dyonne T; Budding, Andries E; Bosscha, Machteld I; Tan, H Stevie; Moll, Annette C

    2017-01-01

    To investigate the causes and treatment options for socket discharge and infection in patients enucleated for retinoblastoma (Rb). A questionnaire was filled out by (parents of) ocular prosthesis-wearing patients with a history of enucleation as treatment for Rb. We collected data on patients' characteristics, cleaning habits of the prosthesis, frequency of socket irritation, discharge, and infection, and use of antibiotics. With ordinal logistic regression analysis, factors related to the outcome parameters (frequency of irritation, mucoid and purulent discharge) were identified. In a subset of young asymptomatic and symptomatic patients, a swab culture of the socket was performed to determine the presence of microorganisms. A total of 186 patients or their parents (mean age of the patients: 17.3 years, ranging from 0.8 to 88.3 years) filled out the questionnaire. Irritation, mucoid discharge, and purulent discharge were frequently (once a month or more often) experienced in 75 (39.5%), 127 (66.8%), and 15 (13.2%) sockets, respectively. Younger age was associated with a higher frequency of mucoid and purulent discharge. Radiation therapy, chemotherapy, gender, age at surgery, cleaning frequency, and nocturnal wear were not associated with the outcome parameters. In a subgroup of 26 patients, the sockets were swabbed and cultured. All symptomatic patients had a positive bacterial culture versus 15% (2/13) of the asymptomatic patients ( P <0.001). Common cold was correlated with both symptoms and presence of bacteria. Haemophilus influenzae and Staphylococcus aureus were the species most frequently cultured. Ocular prosthesis-wearing patients often experienced mucoid discharge, and less often irritation and socket infection. These complaints were found to decrease with increasing age, but did not seem to be influenced by cleaning or wearing habits. Symptomatic sockets, with and without discharge, were correlated with the presence of pathogenic bacteria for which local antibiotic treatment seemed effective in most cases.

  17. In vitro and in vivo evaluation of novel implantation technology in hydrogel contact lenses for controlled drug delivery.

    PubMed

    Maulvi, Furqan A; Lakdawala, Dhara H; Shaikh, Anjum A; Desai, Ankita R; Choksi, Harsh H; Vaidya, Rutvi J; Ranch, Ketan M; Koli, Akshay R; Vyas, Bhavin A; Shah, Dinesh O

    2016-03-28

    Glaucoma is commonly treated using eye drops, which is highly inefficient due to rapid clearance (low residence time) from ocular surface. Contact lenses are ideally suited for controlled drug delivery to cornea, but incorporation of any drug loaded particulate system (formulation) affect the optical and physical property of contact lenses. The objective of the present work was to implant timolol maleate (TM) loaded ethyl cellulose nanoparticle-laden ring in hydrogel contact lenses that could provide controlled drug delivery at therapeutic rates without compromising critical lens properties. TM-implant lenses were developed, by dispersing TM encapsulated ethyl cellulose nanoparticles in acrylate hydrogel (fabricated as ring implant) and implanted the same in hydrogel contact lenses (sandwich system). The TM-ethyl cellulose nanoparticles were prepared by double emulsion method at different ratios of TM to ethyl cellulose. The X-ray diffraction studies revealed the transformation of TM to amorphous state. In vitro release kinetic data showed sustained drug release within the therapeutic window for 168h (NP 1:3 batch) with 150μg loading. Cytotoxicity and ocular irritation study demonstrated the safety of TM-implant contact lenses. In vivo pharmacokinetic studies in rabbit tear fluid showed significant increase in mean residence time (MRT) and area under curve (AUC), with TM-implant contact lenses in comparison to eye drop therapy. In vivo pharmacodynamic data in rabbit model showed sustained reduction in intra ocular pressure for 192h. The study demonstrated the promising potential of implantation technology to treat glaucoma using contact lenses, and could serve as a platform for other ocular diseases. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Induced pluripotent stem cell-derived limbal epithelial cells (LiPSC) as a cellular alternative for in vitro ocular toxicity testing.

    PubMed

    Aberdam, Edith; Petit, Isabelle; Sangari, Linda; Aberdam, Daniel

    2017-01-01

    Induced pluripotent stem cells hold great potential to produce unlimited amount of differentiated cells as cellular source for regenerative medicine but also for in vitro drug screening and cytotoxicity tests. Ocular toxicity testing is mandatory to evaluate the risks of drugs and cosmetic products before their application to human patients by preventing eye irritation or insult. Since the global ban to use animals, many human-derived alternatives have been proposed, from ex-vivo enucleated postmortem cornea, primary corneal cell culture and immortalized corneal epithelial cell lines. All of them share limitations for their routine use. Using an improved protocol, we derived limbal epithelial cells from human induced pluripotent stem cells, named LiPSC, that are able to be passaged and differentiate further into corneal epithelial cells. Comparative RT-qPCR, immunofluorescence staining, flow cytometry analysis and zymography assays demonstrate that LiPSC are morphologically and molecularly similar to the adult stem cells. Moreover, contrary to HCE, LiPSC and primary limbal cells display similarly sensitive to cytotoxicity treatment among passages. Our data strongly suggest that LiPSC could become a powerful alternative cellular model for cosmetic and drug tests.

  19. Induced pluripotent stem cell-derived limbal epithelial cells (LiPSC) as a cellular alternative for in vitro ocular toxicity testing

    PubMed Central

    Aberdam, Edith; Petit, Isabelle; Sangari, Linda

    2017-01-01

    Induced pluripotent stem cells hold great potential to produce unlimited amount of differentiated cells as cellular source for regenerative medicine but also for in vitro drug screening and cytotoxicity tests. Ocular toxicity testing is mandatory to evaluate the risks of drugs and cosmetic products before their application to human patients by preventing eye irritation or insult. Since the global ban to use animals, many human-derived alternatives have been proposed, from ex-vivo enucleated postmortem cornea, primary corneal cell culture and immortalized corneal epithelial cell lines. All of them share limitations for their routine use. Using an improved protocol, we derived limbal epithelial cells from human induced pluripotent stem cells, named LiPSC, that are able to be passaged and differentiate further into corneal epithelial cells. Comparative RT-qPCR, immunofluorescence staining, flow cytometry analysis and zymography assays demonstrate that LiPSC are morphologically and molecularly similar to the adult stem cells. Moreover, contrary to HCE, LiPSC and primary limbal cells display similarly sensitive to cytotoxicity treatment among passages. Our data strongly suggest that LiPSC could become a powerful alternative cellular model for cosmetic and drug tests. PMID:28640863

  20. Management of patients with ocular manifestations in vesiculobullous disorders affecting the mouth.

    PubMed

    Hansen, M S; Klefter, O N; Julian, H O; Lynge Pedersen, A M; Heegaard, S

    2017-10-01

    Pemphigoid and pemphigus diseases as well as Stevens-Johnson syndrome present as vesiculobullous disorders of the skin and may additionally involve both the oral cavity and the ocular surface. Ocular involvement ranges from mild irritation and dry eye disease to chronic conjunctivitis, symblepharon, eyelid malposition, ocular surface scarring and severe visual loss. In addition to diagnostic assessments, ophthalmologists must treat the dry eye and meibomian gland dysfunction components of these diseases using a stepladder approach, including eyelid hygiene and lubricants. Topical anti-inflammatory therapy is used to treat acute inflammatory exacerbations of the ocular surface, but it cannot prevent scarring alone. Intralesional antimetabolite therapy can cause regression of conjunctival pathology in selected cases. Hence, patients with vesiculobullous disorders should be managed by a multidisciplinary team representing ophthalmology, dermatology, otolaryngology, oral medicine and pathology, internal medicine and intensive care. Systemic treatments including corticosteroids, azathioprine, cyclophosphamide, cyclosporine and mycophenolate mofetil help control inflammation. Intravenous immunoglobulins, plasmapheresis and targeted antibody therapy can be used in selected, severe and treatment-resistant cases. Local surgical management may include debridement of pseudomembranes, lysis of symblepharon, amniotic and mucous membrane grafting as well as reconstructive procedures. Prospective, multicentre, international studies are recommended to further support evidence-based practice. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. A survey of recommendations on the care of ocular prostheses.

    PubMed

    Osborn, Katherine L; Hettler, Debbie

    2010-03-01

    The purpose of this study was to determine if there is a consistent set of recommendations for patients who wear an ocular prosthesis or if each patient needs an individual plan. A self-report questionnaire was distributed to members of the American Society of Ocularists. The survey consisted of 4 questions regarding frequency of removal and cleaning and preferred cleaning and lubrication agents. Respondents had 4 weeks to return the survey for results to be included. One hundred three surveys were sent; 8 were undeliverable, leaving a sample size of 95. Thirty-four percent (32 ocularists) responded. The reason with the most frequency for prosthesis removal was only when the prosthesis felt irritated (31%). Fifty-eight percent reported that the ocular prosthesis should be cleaned every time it is removed. Mild soap or baby shampoo was listed as the preferred cleaning agent with 24% each. A majority listed a silicone oil-based lubricant (29%), but responses varied based on the patient's needs. An individualized treatment plan is indicated for most patients who wear an ocular prosthesis. Despite this, some commonalities in responses were noted, specifically that the ocular prosthesis needs to be cleaned with every removal, and a silicone oil lubricant is recommended. Copyright (c) 2010 American Optometric Association. All rights reserved.

  2. Organic-inorganic hybrid nanocomposites based on chitosan derivatives and layered double hydroxides with intercalated phacolysin as ocular delivery system

    NASA Astrophysics Data System (ADS)

    Qin, Zhiguo; Zhang, Jie; Chi, Huibo; Cao, Feng

    2015-12-01

    This study was mainly aimed to evaluate the potential use of a novel ocular drug delivery system, organic-inorganic hybrid nanocomposites based on chitosan derivatives and layered double hydroxides (LDH). Organic polymers of chitosan-glutathione (CG) and pre-activated chitosan-glutathione (CG-2MNA) were successfully synthesized and characterized. LDH with intercalated phacolysin (PCL), including larger hexagonal LDH-PCL (Lh-LDH-PCL), larger spherical LDH-PCL (Ls-LDH-PCL), smaller hexagonal LDH-PCL (Sh-LDH-PCL), CG hybrid LDH-PCL (LDH-PCL-CG), and CG-2MNA hybrid LDH-PCL (LDH-PCL-CG-2MNA), were prepared. The nanocomposites with particle size of 107.2-274.9 nm were characterized by powder X-ray diffraction, Fourier transform infrared, transmission electron micrographs, etc. In vivo precorneal retention studies showed that the detectable time of all nanocomposites was prolonged from 2 to 6 h in comparison to PCL saline. Accordingly, the AUC0-6h values of Lh-LDH-PCL, Ls-LDH-PCL, Sh-LDH-PCL, LDH-PCL-CG, and LDH-PCL-CG-2MNA nanocomposites were increased by 2.27-, 2.08-, 3.08-, 4.67-, and 3.36-fold, respectively. The Draize test and hematoxylin and eosin staining demonstrated that modified LDH had no eye irritation after single and repeated administration. These results indicated that chitosan derivatives-LDH hybrid nanocomposite dispersion could be a promising ocular drug delivery system to improve precorneal retention time of drugs.

  3. Human exposures to pentobarbital-phenytoin combination veterinary drugs.

    PubMed

    Forrester, M B

    2017-07-01

    A combination of pentobarbital and phenytoin is used as a veterinary euthanasia drug. Because of its lethal effect, this study described pentobarbital-phenytoin combination veterinary drug human exposures reported to Texas poison centers during 2000-2015. Of 66 exposures, 73% involved female and 27% male patients. The distribution by patient age was 3% 0-5 years, 5% 6-19 years, 91% 20+ years, and 2% unknown. The most common routes were ocular (41%), ingestion (32%), injection (23%), and dermal (18%). The exposure reasons were unintentional (77%) and intentional (23%). The exposure site was the workplace (52%), patient's own residence (38%), health-care facility (2%), and other/unknown (9%). The management site was managed on site (48%), at/en route to health-care facility (45%), referred to health-care facility (5%), and other (2%). The medical outcomes were no effect (23%), minor effect (30%), moderate effect (8%), major effect (8%), not followed nontoxic (3%), not followed minimal effects (24%), unable to follow potentially toxic (2%), and unrelated (3%). The most common adverse effects were ocular irritation/pain (18%), drowsiness/lethargy (15%), and coma (9%). The most common treatments were dilution/irrigation (70%), intravenous fluids (21%), and oxygen (14%). This study found few pentobarbital-phenytoin combination veterinary drug exposures were reported to Texas poison centers during a 16-year period. Although meant to be administered intravenously, the most common exposure routes were ocular and ingestion. Many of the exposures appeared to be unintentional and occurred at the workplace.

  4. CON4EI: Short Time Exposure (STE) test method for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Adriaens, E; Willoughby, J A; Meyer, B R; Blakeman, L C; Alépée, N; Fochtman, P; Guest, R; Kandarova, H; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids. Copyright © 2017. Published by Elsevier Ltd.

  5. Comparing goblet cell densities in patients wearing disposable hydrogel contact lenses versus silicone hydrogel contact lenses in an extended-wear modality.

    PubMed

    Lievens, Christopher W; Connor, Charles G; Murphy, Heather

    2003-10-01

    The current study evaluates the response of the ocular surface to extended contact lens wear by comparing a new silicone hydrogel lens to an ACUVUE 2 lens. Twenty subjects with an average age of 28 years were randomly assigned to a fitting with ACUVUE 2 or PureVision lenses. Ocular surface assessment by impression cytology was performed at baseline and for the 6 months after initiation of lens wear. Although goblet cell density significantly increased with wear time, no statistically significant difference was observed between the contact lens groups. The average baseline goblet cell percentages were as follows: ACUVUE 2 group, 1.44; PureVision group, 1.11. The 6-month averages were as follows: ACUVUE 2 group, 3.16; PureVision group, 2.22. It appears that silicone hydrogel lenses may be slightly less irritating to the ocular surface than lenses not containing silicone. This could be a promising indicator for successful 30-day continuous wear.

  6. Corneal permeation properties of a charged lipid nanoparticle carrier containing dexamethasone

    PubMed Central

    Ban, Junfeng; Zhang, Yan; Huang, Xin; Deng, Guanghan; Hou, Dongzhi; Chen, Yanzhong; Lu, Zhufen

    2017-01-01

    Drug delivery carriers can maintain effective therapeutic concentrations in the eye. To this end, we developed lipid nanoparticles (L/NPs) in which the surface was modified with positively charged chitosan, which engaged in hydrogen bonding with the phospholipid membrane. We evaluated in vitro corneal permeability and release characteristics, ocular irritation, and drug dynamics of modified and unmodified L/NPs in aqueous humor. The size of L/NPs was uniform and showed a narrow distribution. Corneal permeation was altered by the presence of chitosan and was dependent on particle size; the apparent permeability coefficient of dexamethasone increased by 2.7 and 1.8 times for chitosan-modified and unmodified L/NPs, respectively. In conclusion, a chitosan-modified system could be a promising method for increasing the ocular bioavailability of unmodified L/NPs by enhancing their retention time and permeation into the cornea. These findings provide a theoretical basis for the development of effective drug delivery systems in the treatment of ocular disease. PMID:28243093

  7. Corneal permeation properties of a charged lipid nanoparticle carrier containing dexamethasone.

    PubMed

    Ban, Junfeng; Zhang, Yan; Huang, Xin; Deng, Guanghan; Hou, Dongzhi; Chen, Yanzhong; Lu, Zhufen

    2017-01-01

    Drug delivery carriers can maintain effective therapeutic concentrations in the eye. To this end, we developed lipid nanoparticles (L/NPs) in which the surface was modified with positively charged chitosan, which engaged in hydrogen bonding with the phospholipid membrane. We evaluated in vitro corneal permeability and release characteristics, ocular irritation, and drug dynamics of modified and unmodified L/NPs in aqueous humor. The size of L/NPs was uniform and showed a narrow distribution. Corneal permeation was altered by the presence of chitosan and was dependent on particle size; the apparent permeability coefficient of dexamethasone increased by 2.7 and 1.8 times for chitosan-modified and unmodified L/NPs, respectively. In conclusion, a chitosan-modified system could be a promising method for increasing the ocular bioavailability of unmodified L/NPs by enhancing their retention time and permeation into the cornea. These findings provide a theoretical basis for the development of effective drug delivery systems in the treatment of ocular disease.

  8. Conjugation of cell-penetrating peptides with poly(lactic-co-glycolic acid)-polyethylene glycol nanoparticles improves ocular drug delivery

    PubMed Central

    Vasconcelos, Aimee; Vega, Estefania; Pérez, Yolanda; Gómara, María J; García, María Luisa; Haro, Isabel

    2015-01-01

    In this work, a peptide for ocular delivery (POD) and human immunodeficiency virus transactivator were conjugated with biodegradable poly(lactic-co-glycolic acid) (PGLA)–polyethylene glycol (PEG)-nanoparticles (NPs) in an attempt to improve ocular drug bioavailability. The NPs were prepared by the solvent displacement method following two different pathways. One involved preparation of PLGA NPs followed by PEG and peptide conjugation (PLGA-NPs-PEG-peptide); the other involved self-assembly of PLGA-PEG and the PLGA-PEG-peptide copolymer followed by NP formulation. The conjugation of the PEG and the peptide was confirmed by a colorimetric test and proton nuclear magnetic resonance spectroscopy. Flurbiprofen was used as an example of an anti-inflammatory drug. The physicochemical properties of the resulting NPs (morphology, in vitro release, cell viability, and ocular tolerance) were studied. In vivo anti-inflammatory efficacy was assessed in rabbit eyes after topical instillation of sodium arachidonate. Of the formulations developed, the PLGA-PEG-POD NPs were the smaller particles and exhibited greater entrapment efficiency and more sustained release. The positive charge on the surface of these NPs, due to the conjugation with the positively charged peptide, facilitated penetration into the corneal epithelium, resulting in more effective prevention of ocular inflammation. The in vitro toxicity of the NPs developed was very low; no ocular irritation in vitro (hen’s egg test–chorioallantoic membrane assay) or in vivo (Draize test) was detected. Taken together, these data demonstrate that PLGA-PEG-POD NPs are promising vehicles for ocular drug delivery. PMID:25670897

  9. Evaluation of the inhalation toxicity of diethylethanolamine (DEEA) in rats.

    PubMed

    Hinz, J P; Thomas, J A; Ben-Dyke, R

    1992-04-01

    Diethylethanolamine (DEEA), an industrial anticorrosive additive, was evaluated in rats for its potential toxicity. A 2-week inhalation exposure to 10 ppm revealed no signs of toxicity. At 56 ppm, rats exhibited signs of nasal irritation and corneal opacities. Significant mortality (males, 90%; females, 50%) occurred at 301 ppm. Histopathology revealed inflammatory cell infiltrations of the nasal turbinate mucosa and squamous metaplasia after exposure to 56 ppm. In the 14-week subchronic study, rats were exposed to 0, 11, 25, or 76 ppm. During exposure to DEEA, transient signs of mild to moderate respiratory irritation (noises or rales) were observed with a frequency and severity that was dose dependent. These signs usually cleared within 1 hr post-exposure. However, at 76 ppm some rats continued to exhibit these respiratory signs overnight. There were no significant DEEA-induced changes in either blood chemistry or neurobehavioral parameters. Nasal cavities of rats exposed to 25 or 76 ppm revealed evidence of inflammatory cell infiltration, focal hyperplasia, and squamous metaplasia in the respiratory epithelium of the anterior nasal turbinates. Hypertrophic goblet cells, focal necrosis, and exudate in the nasal lumen were also seen at 76 ppm. DEEA vapors failed to produce persistent ocular or respiratory tract toxicity below 26 ppm. The no-observed-effect-level in this study was 10 ppm.

  10. Fixed combination of bimatoprost and timolol in patients with primary open-angle glaucoma or ocular hypertension with inadequate IOP adjustment

    PubMed Central

    Brief, Gerrett; Lammich, Tobias; Nagel, Edgar; Pfennigsdorf, Sabine; Spraul, Christoph W; Ho, Selwyn

    2010-01-01

    Objective To assess the efficacy and tolerability of a fixed combination of bimatoprost and timolol (BTFC) in a large patient sample in a clinical setting. Methods In this multicenter, observational, noncontrolled, open-label study, patients (n = 1862) with primary open-angle glaucoma or ocular hypertension were treated with BTFC. Assessments were made at baseline, six weeks, and three months. Results Prior to starting BTFC, 92.3% of patients were taking other ocular hypotensive medications. In the overall group at three months, mean intraocular pressure was reduced from baseline (21.7 ± 4.5 mmHg and 21.8 ± 4.9 mmHg for the right and left eye, respectively) to 16.1 ± 3.0 mmHg for each eye (P < 0.0001). The majority of patients (92%) reported no adverse events. The most commonly reported adverse events (in >1% of patients) were eye irritation, and ocular and conjunctival hyperemia. Adherence to treatment was generally better than (35.4%) or the same as (57.5%) with prior therapy. BTFC tolerability was rated as excellent or good by 92.3% of physicians and 85.8% of patients. Conclusions In a large group of patients with primary open-angle glaucoma or ocular hypertension, treatment with BTFC was associated with consistent reductions in IOP, improved adherence to treatment, and good tolerability. PMID:20957059

  11. Development of Dorzolamide Loaded 6-O-Carboxymethyl Chitosan Nanoparticles for Open Angle Glaucoma

    PubMed Central

    Ahmed, Mohammed Hadi

    2013-01-01

    Chitosan (CS) is a biodegradable, biocompatible, and mucoadhesive natural polymer soluble in acidic pH only and can be irritating to the eye. Objective of the study was to synthesize water soluble 6-O-carboxymethyl (OCM-CS) derivative of CS, and to develop CS and OCM-CS nanoparticles (NPs) loaded with dorzolamide hydrochloride (DRZ). CS was reacted with monochloroacetic acid (MCA) for OCM-CS synthesis and was characterized by FT-IR, DSC, and 13C NMR. CS and OCM-CS NPs were prepared by ionic gelation method. Ocular irritation potential were evaluated and therapeutic efficacy was measured by reduction in intraocular pressure (IOP) in normotensive rabbits. Maximum yield was obtained when the ratio of water/isopropyl alcohol was 1/4 at 55°C. The FT-IR, DSC and 13C NMR confirmed the formation of an ether linkage between hydroxyl groups of CS and MCA. The particle size and zeta potential of optimised CSNPs was 250.3 ± 2.62 nm and +33.47 ± 0.723 mV, whereas those for OCM-CSNPs were 187.1 ± 2.72 nm and 30.87 ± 0.86 mV. The entrapment efficiency was significantly improved for OCM-CSNPs, compared to CSNPs. OCM-CSNPs had tailored drug release and improved bioavailability with reduction in pulse entry as compared to CSNPs. Hence, it can be concluded that DRZ loaded OCM-CSNPs would be better alternative option to available eye drops for glaucoma treatment. PMID:24222858

  12. Development of dorzolamide loaded 6-o-carboxymethyl chitosan nanoparticles for open angle glaucoma.

    PubMed

    Shinde, Ujwala; Ahmed, Mohammed Hadi; Singh, Kavita

    2013-01-01

    Chitosan (CS) is a biodegradable, biocompatible, and mucoadhesive natural polymer soluble in acidic pH only and can be irritating to the eye. Objective of the study was to synthesize water soluble 6-O-carboxymethyl (OCM-CS) derivative of CS, and to develop CS and OCM-CS nanoparticles (NPs) loaded with dorzolamide hydrochloride (DRZ). CS was reacted with monochloroacetic acid (MCA) for OCM-CS synthesis and was characterized by FT-IR, DSC, and (13)C NMR. CS and OCM-CS NPs were prepared by ionic gelation method. Ocular irritation potential were evaluated and therapeutic efficacy was measured by reduction in intraocular pressure (IOP) in normotensive rabbits. Maximum yield was obtained when the ratio of water/isopropyl alcohol was 1/4 at 55°C. The FT-IR, DSC and (13)C NMR confirmed the formation of an ether linkage between hydroxyl groups of CS and MCA. The particle size and zeta potential of optimised CSNPs was 250.3 ± 2.62 nm and +33.47 ± 0.723 mV, whereas those for OCM-CSNPs were 187.1 ± 2.72 nm and 30.87 ± 0.86 mV. The entrapment efficiency was significantly improved for OCM-CSNPs, compared to CSNPs. OCM-CSNPs had tailored drug release and improved bioavailability with reduction in pulse entry as compared to CSNPs. Hence, it can be concluded that DRZ loaded OCM-CSNPs would be better alternative option to available eye drops for glaucoma treatment.

  13. Impact of wildfire smoke in Buenos Aires, Argentina, on ocular surface.

    PubMed

    Berra, Martin; Galperín, Gustavo; Dawidowski, Laura; Tau, Julia; Márquez, Isabel; Berra, Alejandro

    2015-01-01

    To evaluate the acute impact of the wildfire smoke episode in 2008 on the ocular surface of subjects living in the Metropolitan Area of Buenos Aires (MABA). A total of 86 subjects were evaluated: Group 1 comprised patients from a public ophthalmology hospital (N=35) and Group 2 comprised healthy volunteers (N=51). All subjects answered a questionnaire on ocular symptoms and underwent ophthalmologic examination [bulbar conjunctival hyperemia, corneal fluorescein staining, rose bengal vital staining, tear break-up time (TBUT), Schirmer I test, tear lysozyme, and impression cytology] during and after the acute episode. Concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), and particulate matter (PM) were measured before, during, and after the acute episode. Both groups showed a statically significant increase in ocular symptoms and bulbar conjunctival hyperemia and a statically significant decrease in tear break-up time during the acute episode. Group 1 showed more severe symptoms and a statistically significant increase in fluorescein and rose bengal staining intensities during the acute episode. We found a significant negative correlation between ocular symptoms and tear break-up time. During the episode, the levels of CO, NO2, and particulate matter in MABA were four times higher than the usual average levels for the same period in 2007 and 2009. Increased air pollution from the burning of biomass is associated with a decrease in the stability of the tear film (TBUT), generating areas of ocular surface exposure that may be the cause of the increased feeling of irritation. Group 1 was more affected by not having a healthy ocular surface, and thus consulted an ophthalmologist. Cytological changes in the conjunctiva were not observed, which could be due to the short duration of the episode.

  14. Methyl trypsin loaded poly(D,L-lactide-coglycolide) nanoparticles for contact lens care.

    PubMed

    Jimenez, N; Galan, J; Vallet, A; Egea, M A; Garcia, M L

    2010-03-01

    The need of an enzymatic cleaner for soft contact lens care with an improved ocular safety and stability profile led us to evaluate the use of nanoparticles (NPs) of poly(D,L-lactide-coglycolide) (PLGA) and methyl trypsin (MT). NPs were prepared by double emulsion-solvent evaporation technique. A factorial design was performed to select the lactic acid proportion in the copolymer and conditions of the second sonication. The increment in proportion of lactic acid provided higher particle size results. When the time of second sonication was decreased, the entrapment efficiency (EE) increased. PLGA 50:50 NPs were chosen for further development since PLGA 50:50H NPs settled fast with different particle size in the sediment and PLGA 75:25 NPs led to form aggregates. The addition of glycerol to the NPs provided the highest EE of MT (>90%) while the addition of Tetronic 1304 promoted the fast release of enzyme initially and decreased the zeta potential (zeta) up to neutral values after gamma irradiation. NPs are expected to be effective as a lens care cleaner after 3 days or even longer with a very low quantity of enzyme released. Formulations showed an acceptable irritation ocular tolerance after in vitro HET-CAM test and in vivo Draize test. 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  15. Topical dobesilate eye drops for ophthalmic primary pterygium

    PubMed Central

    Cuevas, Pedro; Outeiriño, Luis A; Angulo, Javier; Giménez-Gallego, Guillermo

    2012-01-01

    Selective inhibition of fibroblast growth factor and vascular endothelial growth factor signalling pathways is effective in causing regression of pterygia. Prompt regression of fibrovascular mass and conjunctival angiogenesis was documented 2 weeks after topical administration of dobesilate eye drops twice daily. At 3-month follow-up, no recurrence was seen and no ocular irritation and burning were noted. The authors believe that this is the first known successful use of topical dobesilate in primary pterygium. PMID:22605609

  16. Studies on ocular and parenteral application potentials of azithromycin- loaded anionic, cationic and neutral-charged emulsions.

    PubMed

    Tamilvanan, Shunmugaperumal; Khanum, Ramona; Senthilkumar, Sudalimuthu Ramachandran; Muthuraman, Marimuthu; Rajasekharan, Thenrajan

    2013-10-01

    Ocular and parenteral application potentials of azithromycin-containing, non-phospholipid-based cationic nanosized emulsion in comparison to the phospholipid-based anionic and neutral-charged nanosized emulsions were investigated. Various physical, chemical, nonclinical toxicity and antimicrobial activity studies (mean droplet diameter, surface charge, creaming index, entrapment efficiency, accelerated, long-term and freeze-thaw cycling stabilities, TLC study, modified hen's egg chorioallantoic membrane (HET-CAM) test, in vitro hemolysis test, in vitro and in vivo myotoxicity, and in vitro antimicrobial activity) were conducted for assessing the potentials of these three types of emulsions. Following autoclave sterilization, all of these emulsions exhibited a nanometer range mean particle diameter (200 ± 29 to 434 ± 13 nm). While the anionic and cationic emulsions did show high negative (-34.2 ± 1.23 mV) and positive zeta potential (42.6 ± 1.45 mV) values, the neutral-charged emulsion did not. Even with 5 freeze-thaw cycles, the cationic emulsion remained stable whereas other two emulsions underwent phase-separation. The hen's egg chorioallantoic membrane test revealed an irritation score value that was higher for the anionic emulsion than for cationic or neutral-charged emulsion. A significantly higher % hemolysis value was also noticed for the anionic emulsion when compared to the % hemolysis value of cationic emulsion (ANOVA, P ‹ 0.05). However, all of the emulsions showed a lesser intracellular creatine kinase (CK) release/plasma CK level in comparison to the positive control (phenytoin) indicating their lesser myotoxicity at the injection site . When compared to anionic and neutral-charged emulsions, the possible controlled drug release from cationic emulsion delayed the in vitro antimicrobial action against H.influenzae and S.pneumoniae.

  17. Development of Ocular Delivery System for Glaucoma Therapy Using Natural Hydrogel as Film Forming Agent and Release Modifier.

    PubMed

    Kulkarni, Giriraj T; Sethi, Nitin; Awasthi, Rajendra; Pawar, Vivek Kumar; Pahuja, Vineet

    2016-01-01

    Glaucoma is characterized by increased intraocular pressure, which results in damage to the optic nerve. The existing therapy with conventional eye drops is inefficient due to nasolachrymal drainage, resulting in a reduced corneal residence of the drug. The objective was to develop controlled-release ocular films of timolol maleate using natural hydrogel from Tamarindus indica seeds as a sustaining and film-forming agent, to overcome the problems associated with eye drops. The hydrogel was isolated using hot aqueous extraction followed by precipitation with ethanol. Six batches of ocular films were prepared and evaluated for drug content, weight variation, thickness, diameter and in vitro release profile. The ideal batch of the films was subjected to stability, pharmacodynamic and ocular safety studies. The yield of the hydrogel was 58.29%. The thickness of the ocular films was in the range of 0.17 to 0.25 mm and the weight of the films was found to increase with the increase in polymer content. The drug release from the films was found to be controlled over a period of 8 h. The films were found to be stable and were able to reduce the intraocular pressure for 24 h in a more efficient manner than the eye drops. The films were found to be practically non-irritating to the eye. It can be concluded that the hydrogel from tamarind seeds can be used as a film-forming and release-controlling agent for the development of an ocular drug delivery system for the effective therapy of glaucoma.

  18. Final report on the safety assessment of octoxynol-1, octoxynol-3, octoxynol-5, octoxynol-6, octoxynol-7, octoxynol-8, octoxynol-9, octoxynol-10, octoxynol-11, octoxynol-12, octoxynol-13, octoxynol-16, octoxynol-20, octoxynol-25, octoxynol-30, octoxynol-33, octoxynol-40, octoxynol-70, octoxynol-9 carboxylic acid, octoxynol-20 carboxylic acid, potassium octoxynol-12 phosphate, sodium octoxynol-2 ethane sulfonate, sodium octoxynol-2 sulfate, sodium octoxynol-6 sulfate, and sodium octoxynol-9 sulfate.

    PubMed

    Johnson, Wilbur

    2004-01-01

    Octoxynols are ethoxylated alkylphenols in which the size of the molecule is related to the number of moles of ethylene oxide used in synthesis. Reactions are performed at elevated temperature, under pressure, and in the presence of NaOH. It is possible that the synthesis may leave trace amounts of ethylene oxide, 1,4-dioxane, and unreacted C9 phenols. Octoxynols of various chain lengths as well as octoxynol salts and organic acids function in cosmetics either as surfactants--emulsifying agents, surfactants--cleansing agents, surfactant--solubilizing agents, or surfactants--hydrotropes in a wide variety of cosmetic products at concentrations ranging from 0.0008% to 25%, with most less than 5.0%. The octoxynols are chemically similar to nonoxynols, the safety of which were previously considered. Long-chain nonoxynols (9 and above) were considered safe as used, whereas short-chain nonoxynols (8 and below) were considered safe as used in rinse-off products and safe at concentrations less than 5% in leave-on formulations. Acute exposure of hamsters to Octoxynol-9 by bronchopulmonary lavage produced pneumonia, pulmonary edema, and intra-alveolar hemorrhage. Octoxynol-9 at doses over 1 g/kg was toxic in rats and in mice in acute oral toxicity studies. No significant effects were noted in short-term oral studies of Octoxynol-9 in rats, in subchronic oral studies of Octoxynol-40 in rats and dogs, or in chronic oral studies of Octoxynol-40 in rats. The intraperitoneal LD50 of Octoxynol-9 in rats and mice was around 100 mg/kg. In skin irritation studies, octoxynols ranged from nonirritating to moderately irritating. Octoxynols were not ocular irritants in one rabbit study, but in others there was ocular irritation. No immune system toxicity in CF-1 female mice was noted following the intraperitoneal injection of Octoxynol-9 followed by subcutaneous immunization with sheep red blood cells (SRBCs). Octoxynol-9 produced no humoral and cell-mediated immune responses, or autoimmune response in mice. In the Ames test, Octoxynol-1 was not mutagenic with and without metabolic activation nor was Octoxynol-9 clastogenic. Results for Octoxynol-9 were negative in the following assays: unscheduled DNA synthesis, hypoxanthine guanine phosphoribosyl transferase mutation assay, malignant transformation assay, DNA alkaline unwinding test, and mouse lymphoma thymidine kinase locus forward mutation assay. Ethoxylated alkylphenols are generally considered to be estrogenic in that they mimic the effects of estradiol. Dermal exposure at three dose levels of rats to Octoxynol-9 failed to induce any malformations by category (external, visceral, or skeletal) or by individual anatomical location that were different from controls at statistically significant level. An increased incidence of a vestigial thoracic rib was observed in all dose groups. Octoxynol-9 also did not induce developmental toxicity (number of viable litters, liveborn per litter, percentage survival, birth weight per pup, and weight gain per pup) in female specific pathogen-free CD-1 mice dosed daily by gavage on gestation days 6 through 13. No reproductive toxicity was seen in male albino rats which received 5% Octoxynol-40 in the diet daily for 3 months; however, in an in vitro test, Octoxynol-9 (0.24 mg/ml) totally immobilized all human spermatozoa within 20 s. Women who used Nonoxynol-9 or Octoxynol-9 as spermicides, but who did become pregnant, did not have an increase in the overall risk of fetal malformations. In a human skin irritation study, formulations containing 2.0% Octoxynol-9 were classified as moderately irritating and minimally irritating, respectively, in a 24-h single-insult, occlusive patch test. Octoxynol-9 (1.0%) was classified as a nonirritant in a clinical study of nine subjects patch tested for 4 consecutive days. The skin sensitization potential of Octoxynols-1, -3, -5, -9, and -13 was evaluated using 50 subjects. Octoxynol-1 induced sensitization in two subjects; all other results were negative. No sensitization was observed in the following studies: 8.0% Octoxynol-9 in 103 subjects, 0.5% Octoxynol-9 in 102 subjects, and 0.1% Octoxynol-9 in 206 subjects. Concerns about even trace levels of 1,4-dioxane, ethylene oxide, or unreacted C9 led to the recommendation that levels be limited. Concerns about the ocular irritancy of short-chain octoxynols led to a recommendation that they should not be used in products that will be used in the area surrounding the eyes. A limitation on the use concentration for short-chain octoxynols (8 and below) arose from consideration of the skin sensitization potential of octoxynols and the recognition that the short-chain octoxynols could be absorbed into the skin more than the long-chain octoxynols. Overall, based on the available data, it was concluded that long-chain octoxynols (9 and above) are safe as used, whereas short-chain octoxynols (8 and below) are safe as used in rinse-off products and safe at concentrations less than 5% in leave-on formulations.

  19. RES-loaded pegylated CS NPs: for efficient ocular delivery.

    PubMed

    Pandian, Saravanakumar; Jeevanesan, Vinoth; Ponnusamy, Chandrasekar; Natesan, Subramanian

    2017-02-01

    The objective of this study is to develop resveratrol (RES) loaded polyethylene glycols (PEGs) modified chitosan (CS) nanoparticles (NPs) by ionic gelation method for the treatment of glaucoma. While increasing the concentration of PEG, the particle size and polydispersity index of the formulations increased. Entrapment efficiency and RES loading (RL) of NPs decreased while increasing PEG concentration. The in vitro release of NPs showed an initial burst release of RES (45%) followed by controlled release. Osmolality of formulations revealed that the prepared NPs were iso-osmolar with the tear. Ocular tolerance of the NPs was evaluated using hen's egg test on the chorioallantoic membrane and it showed that the NPs were non-irritant. RES-loaded PEG-modified CS NPs shows an improved corneal permeation compared with RES dispersion. Fluorescein isothiocyanate loaded CS NPs accumulated on the surface of the cornea but the PEG-modified CS NPs crossed the cornea and reached retinal choroid. RES-loaded PEG-modified CS NPs reduced the intra-ocular pressure (IOP) by 4.3 ± 0.5 mmHg up to 8 h in normotensive rabbits. These results indicate that the developed NPs have efficient delivery of RES to the ocular tissues and reduce the IOP for the treatment of glaucoma.

  20. Neuropathic ocular pain due to dry eye is associated with multiple comorbid chronic pain syndromes

    PubMed Central

    Galor, Anat; Covington, Derek; Levitt, Alexandra E.; McManus, Katherine T.; Seiden, Benjamin; Felix, Elizabeth R.; Kalangara, Jerry; Feuer, William; Patin, Dennis J.; Martin, Eden R.; Sarantopoulos, Konstantinos D.; Levitt, Roy C.

    2015-01-01

    Recent data demonstrate that dry eye (DE) susceptibility and other chronic pain syndromes (CPS) such as chronic widespread pain, irritable bowel syndrome and pelvic pain, may share common heritable factors. Previously, we showed that DE patients describing more severe symptoms tended to report features of neuropathic ocular pain (NOP). We hypothesize that patients with a greater number of CPS would have a different DE phenotype compared to those with fewer CPS. We recruited a cohort of 154 DE patients from the Miami Veterans Affairs Hospital and defined high and low CPS groups by cluster analysis. In addition to worse non-ocular pain complaints and higher PTSD and depression scores (P<0.01), we found that the high CPS group reported more severe neuropathic-type DE symptoms compared to the low CPS group, including worse ocular pain assessed via 3 different pain scales (P<0.05), with similar objective corneal DE signs. This is the first study to demonstrate DE patients who manifest a greater number of comorbid CPS report more severe DE symptoms and features of NOP. These findings provide further evidence that NOP may represent a central pain disorder, and that shared mechanistic factors may underlie vulnerability to some forms of DE and other comorbid CPS. PMID:26606863

  1. Topical drug delivery to the eye: dorzolamide.

    PubMed

    Loftsson, Thorsteinn; Jansook, Phatsawee; Stefánsson, Einar

    2012-11-01

    Topically applied carbonic anhydrase inhibitors (CAIs) in eye drop solutions are commonly used to treat glaucoma. However, local eye irritation and multiple daily administrations may hamper their clinical usefulness. Aqueous eye drop formulations that improve their topical bioavailability and reduce their eye irritation can improve their clinical efficacy. Earlier studies showed that dorzolamide and closely related CAIs are more effectively delivered into the eye from acidic eye drop solutions than from comparable neutral solutions. Consequently, dorzolamide was marketed as an aqueous pH 5.6 eye drop solution (Trusopt(®) , Merck). Later, it was shown that increasing the pH of the eye drops from pH 5.6 to physiologic pH significantly reduced their local irritation. Earlier attempts to use cyclodextrins (CDs) as ocular penetration enhancers in dorzolamide eye drop solutions failed since; although the CDs were able to enhance the aqueous solubility of dorzolamide, increasing the pH from 5.6 to physiologic pH reduced the ability of the drug to permeate into the eye. Later, it was discovered that formulating the drug as aqueous dorzolamide/γCD eye drop microparticle suspension resulted in significant bioavailability enhancement. The solid dorzolamide/γCD microparticles are mucoadhesive and release dorzolamide into the aqueous tear fluid for extended time period. Consequently, sustained high dorzolamide concentrations in aqueous humour and various eye tissues were observed after single administration of the aqueous dorzolamide/γCD eye drop microsuspension. The microsuspension has a potential of being developed into a once-a-day eye drop product. This article reviews the physicochemical properties of dorzolamide, its permeation characteristics and topical bioavailability. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  2. Understanding and preventing computer vision syndrome.

    PubMed

    Loh, Ky; Redd, Sc

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  3. Preventing Vision Loss from Blast Injuries with Regenerative Biomaterial

    DTIC Science & Technology

    2013-08-01

    4 2.1: Task 1: Irritation response to silk films….……………………………………... 4 2.2: Task 2: Abrasive wound assessment...protein for use on the ocular surface. Over 6 million Americans sustain traumatic injuries each year from both accidents and surgical procedures. In...addition, eye injury is the number one cause of field evacuation in the military. Corneal wounds cause intense pain and may lead to blindness

  4. Acute Parotitis as a Complication of Noninvasive Ventilation.

    PubMed

    Alaya, S; Mofredj, Ali; Tassaioust, K; Bahloul, H; Mrabet, A

    2016-09-01

    Several conditions, including oropharyngeal dryness, pressure sores, ocular irritation, epistaxis, or gastric distension, have been described during noninvasive ventilation (NIV). Although this technique has been widely used in intensive care units and emergency wards, acute swelling of the parotid gland remains a scarcely reported complication. We describe herein the case of an 82-year-old man who developed unilateral parotitis during prolonged NIV for acute heart failure. Intravenous antibiotics, corticosteroids, and adjusting the mask laces' position allowed rapid resolution of clinical symptoms. © The Author(s) 2016.

  5. Final report of the Cosmetic Ingredient Review Expert Panel amended safety assessment of Calendula officinalis-derived cosmetic ingredients.

    PubMed

    Andersen, F Alan; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W

    2010-01-01

    Calendula officinalis extract, C officinalis flower, C officinalis flower extract, C officinalis flower oil, and C officinalis seed oil are cosmetic ingredients derived from C officinalis. These ingredients may contain minerals, carbohydrates, lipids, phenolic acids, flavonoids, tannins, coumarins, sterols and steroids, monoterpenes, sesquiterpenes, triterpenes, tocopherols, quinones, amino acids, and resins. These ingredients were not significantly toxic in single-dose oral studies using animals. The absence of reproductive/developmental toxicity was inferred from repeat-dose studies of coriander oil, with a similar composition. Overall, these ingredients were not genotoxic. They also were not irritating, sensitizing, or photosensitizing in animal or clinical tests but may be mild ocular irritants. The Cosmetic Ingredient Review (CIR) Expert Panel concluded that these ingredients are safe for use in cosmetics in the practices of use and concentration given in this amended safety assessment.

  6. Final report of the safety assessment of cosmetic ingredients derived from Zea mays (corn).

    PubMed

    Andersen, F Alan; Bergfeld, Wilma F; Belsito, Donald V; Klaassen, Curtis D; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W

    2011-05-01

    Many cosmetic ingredients are derived from Zea mays (corn). While safety test data were not available for most ingredients, similarities in preparation and the resulting similar composition allowed extrapolation of safety data to all listed ingredients. Animal studies included acute toxicity, ocular and dermal irritation studies, and dermal sensitization studies. Clinical studies included dermal irritation and sensitization. Case reports were available for the starch as used as a donning agent in medical gloves. Studies of many other endpoints, including reproductive and developmental toxicity, use corn oil as a vehicle control with no reported adverse effects at levels used in cosmetics. While industry should continue limiting ingredient impurities such as pesticide residues before blending into a cosmetic formulation, the CIR Expert Panel determined that corn-derived ingredients are safe for use in cosmetics in the practices of use and concentration described in the assessment.

  7. Thermosetting gels with modulated gelation temperature for ophthalmic use: the rheological and gamma scintigraphic studies.

    PubMed

    Wei, Gang; Xu, Hui; Ding, Ping Tian; Li, San Ming; Zheng, Jun Min

    2002-09-18

    For ophthalmic drug delivery, Pluronic F127 solutions have a phase transition temperature too low for them to be instilled into the eye at room temperature. Refrigerator storage is usually required to make administration easier, whereas the potential irritation of cold to the sensitive ocular tissues may result in poor topical bioavailability. The purpose of this study is to develop a thermosetting gel with a suitable phase transition temperature by combining Pluronic analogs and to examine the influence of incorporating mucoadhesive polysaccharide, sodium hyaluronate (HA-Na), on the ocular retention of the gel. Dynamic rheological method and single photon emission computing tomography (SPECT) technique were used to ex/in vivo evaluate the thermosetting gels, respectively. An optimized formulation containing 21% F127 and 10% F68 increased the phase transition temperature by 9 degrees C as evaluated by elasticity modulus compared to that of individual 21% F127 solution. Rheological behaviors of the Pluronic solutions showed that the combined Pluronic formulation was free flowing liquid below 25 degrees C and converted to a firm gel under the physiological condition. Furthermore, this formulation possessed the highest viscosity both before and after tear dilution at 35 degrees C. Gamma scintigraphic data demonstrated that the clearance of the thermosetting gel labeled with 99mTc-DTPA was significantly delayed with respect to the phosphate buffered solution, and at least a threefold increase of the corneal residence time was achieved. However, no further improvement in the ocular retention was observed when adding HA-Na into the thermosetting gel due to the substantially decreased gel strength. Copyright 2002 Elsevier Science B.V.

  8. Corneal anesthesia following application of 0.4% oxybuprocaine hydrochloride ophthalmic solution to normal feline eyes.

    PubMed

    Giudici, Valentina; Baeza, Sophia; Douet, Jean-Yves; Regnier, Alain

    2015-03-01

    To evaluate the loss and recovery of corneal sensitivity after instillation of 0.4% oxybuprocaine hydrochloride solution in the normal feline eye. Eighteen European shorthair cats free of ocular disease Baseline corneal touch threshold (CTT) readings were obtained bilaterally with a Cochet-Bonnet aesthesiometer prior to treatment. Subsequently, each cat received a single drop of 0.4% oxybuprocaine ophthalmic solution in the right eye and one drop of sterile 0.9% NaCl in the left eye to serve as control. The corneal touch threshold (CTT) of both eyes was then measured 1 min after drug administration and every 5 min for 60 min. The potential for ocular irritation following oxybuprocaine application was also evaluated. Baseline CTT readings were not significantly different (P > 0.05) between the control and oxybuprocaine-treated eyes with values of 1.75 ± 0.31 cm and 1.75 ± 0.30 cm, respectively. In control eyes, mean CTT did not significantly change (P > 0.05) during the study period. By contrast, after oxybuprocaine application mean CTT was significantly reduced from baseline (P < 0.05) for 45 min. Maximal corneal anesthesia, with a CTT value of 0, was achieved at 1 and 5 min in all treated eyes. A markedly reduced mean CTT of 0.14 ± 0.23 cm was still present at 20 min. Age and gender did not significantly affect corneal anesthesia. No clinically relevant ocular side effects occurred during the observation period. This is the first study that provides objective information on the depth and duration of corneal anesthesia following instillation of oxybuprocaine in healthy feline eyes. © 2014 American College of Veterinary Ophthalmologists.

  9. Sustained ocular delivery of brimonidine tartrate using ion activated in situ gelling system.

    PubMed

    Geethalakshmi, A; Karki, Roopa; Jha, Sajal Kumar; Venkatesh, D P; Nikunj, B

    2012-03-01

    The poor bioavailability and therapeutic response exhibited by conventional eye drops due to rapid precorneal elimination of the drug may be overcome by the use of an in situ gelling systems that are instilled as drops into the eye and undergo a sol-to-gel transition in the cul-de-sac which improves patient compliance as the dosage regimen is one drop of the dosage form twice a day. The loss of drug overcomes due to the immediate gel formation between the eye membrane and the drug being entrapped simultaneously in sol-gel transition in the cul de sac. The present work describes the formulation and evaluation of an ophthalmic delivery system of an antiglaucomal agent, brimonidine tartrate based on the concept of ion-activated in situ gelation. Gelrite was used as the gelling agent, which gels in the presence of mono or divalent cations present in the lacrimal fluid. The formulations were evaluated for clarity, pH measurement, gelling capacity, drug content estimation, rheological study, in-vitro diffusion study, antibacterial activity, isotonicity testing, eye irritation testing. In the developed formulations Gelrite Brimonidine-3 (GB3) exhibited sustained release of drug from formulation over a period of 8 hrs thus increasing residence time of the drug, non-irritating with no ocular damage or abnormal clinical signs to the cornea, iris or conjunctiva, stable and sterile. These results demonstrate that the developed system is an alternative to conventional ophthalmic drops, with better patient compliance, and is industrially oriented and economical.

  10. In vitro and in vivo ocular safety and eye surface permanence determination by direct and Magnetic Resonance Imaging of ion-sensitive hydrogels based on gellan gum and kappa-carrageenan.

    PubMed

    Fernández-Ferreiro, Anxo; González Barcia, Miguel; Gil-Martínez, María; Vieites-Prado, Alba; Lema, Isabel; Argibay, Barbara; Blanco Méndez, José; Lamas, Maria Jesus; Otero-Espinar, Francisco Javier

    2015-08-01

    Gellan gum, kappa-carrageenan and alginates are natural polysaccharides able to interact with different cations that can be used to elaborate ion-activated in situ gelling systems for different uses. The interaction between fluid solutions of these polysaccharides and cations presents into the tear made these biopolymers very interesting to elaborate ophthalmic drug delivery systems. The main purpose of this study is to evaluate the ability of mixtures of these polymers to obtain ion-activated ophthalmic in situ gelling systems with optimal properties for ocular use. To achieve this purpose different proportion of the biopolymers were analyzed using a mixture experimental design evaluating their transparency, mechanical properties and bioadhesion in the absence and presence of simulated tear fluid. Tear induces a rapid sol-to-gel phase transition in the mixtures forming a consistent hydrogel. The solution composed by 80% of gellan gum and 20% kappa-carrageenan showed the best mechanical and mucoadhesive properties. This mixture was evaluated for rheological behavior, microstructure, cytotoxicity, acute corneal irritancy, ex-vivo and in vivo ocular toxicity and in vivo corneal contact time using Magnetic Resonance Images (MRI) techniques. Result indicates that the system is safe at ophthalmic level and produces an extensive ocular permanence higher than 6h. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. [Air conducted ocular VEMP: II. First clinical investigations].

    PubMed

    Walther, L E; Schaaf, H; Sommer, D; Hörmann, K

    2011-10-01

    Vestibular-evoked myogenic potentials (VEMP) are widely used to assess vestibular function. Air conducted (AC) cervical VEMP (cVEMP) reflect sacculus and inferior vestibular nerve function. Ocular VEMP (oVEMP) however has been hardly examined up to now. In recent studies it has been assumed that AC oVEMP probably reflects superior vestibular nerve function. The aim of this pilot study was to evaluate clinical application of the AC oVEMP. AC oVEMP were recorded in patients with peripheral vestibular disorders (n=21). In addition thermal irritation and head impulse test were performed and AC cVEMP were recorded. For intense AC-sound stimulation tone bursts (500 Hz) with 100 dB nHL were used. In peripheral vestibular disorders AC oVEMP and AC cVEMP could be classified into: • type 1 (inferior vestibular neuritis) with loss of AC oVEMP but normal AC cVEMP, • type 2, probable type of superior vestibular neuritis, showing present AC cVEMP but loss of AC oVEMP, • type 3, probable complete vestibular neuritis, without AC oVEMP and AC cVEMP. AC oVEMP may be used as an appropriate test for clinical investigation in patients with vestibular disorders. AC oVEMP is an additional, essential test for assessing otolith function beside AC cVEMP. Further vestibular test are necessary for precise clinical interpretation. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Respiratory and ocular symptoms among employees of a hotel indoor waterpark resort--Ohio, 2007.

    PubMed

    2009-02-06

    During January--March 2007, the Warren County Combined Health District (WCCHD) received 665 reports of respiratory and eye irritation from patrons and lifeguards at a hotel indoor waterpark resort in Ohio. Tests revealed normal water chemistry and air chlorine concentrations, and exposure to airborne trichloramine in the waterpark was suspected as the cause of the symptoms. Because of the number of symptom reports and WCCHD's limited ability to measure trichloramine, the district requested an investigation by CDC's National Institute for Occupational Safety and Health (NIOSH). This report describes the results of that investigation, which revealed that trichloramine concentrations in the waterpark ranged from below the limit of detection to 1.06 mg/m3, and some concentrations were at levels that have been reported to cause irritation symptoms (>/=0.5 mg/m3). Lifeguards reported significantly more work-related symptoms (e.g., cough, wheezing, shortness of breath, chest tightness, and eye irritation) than unexposed hotel employees. Lifeguards also reported significantly more eye irritation and cough on days when hotel occupancy was high versus low. Insufficient air movement and distribution likely led to accumulation of trichloramine and exacerbation of symptoms. Based on recommendations to increase air movement and distribution at pool deck level, hotel management modified the ventilation system extensively, and subsequently no new cases were reported to WCCHD. The results of this investigation emphasize the importance of appropriate design and monitoring of ventilation and water systems in preventing illness in indoor waterparks.

  13. Prickly Pear Spine Keratoconjunctivitis

    PubMed Central

    Odat, Thabit Ali Mustafa; Al-Tawara, Mohammad Jebreel; Hammouri, Eman Hussein

    2014-01-01

    Objectives: To study the ocular and extra-ocular features, clinical presentation, and treatment of prickly pear glochids. Materials and Methods: This retrospective study included 23 eyes of 21 patients with ocular prickly pear spines who were seen between August and October 2011 in the outpatient ophthalmic clinic at Prince Rashid Bin Al Hassan military hospital in Jordan. Medical records of patients including age, gender, history of exposure to prickly pear plants, and ocular examination were reviewed. All glochids were localized and removed with forceps under topical anesthesia with the patient at the slit lamp. Patients were followed up after one week. Results: The mean age of patients was 37.1 years with a male to female ratio of 1.6: 1. Involvement of the right eye was seen in 61.9% patients, left eye in 28.6% patients, and bilateral involvement in 9.5% patients. Glochids were most commonly found in the upper subtarsal conjunctival space (47.6%) followed by inferior palpebral conjunctiva in 23.8% eyes. The most common complaint was eye irritation in 95.2% patients. Pain was a complaint in 57.1% patients. Superior corneal epithelial erosions or ulcer were found in 33.3% patients, inferior corneal epithelial erosions in 19.1% patients, and diffuse epithelial erosions in 9.5% patients. Glochids were found in other parts of the body in 38.1% patients. Conclusion: Although prickly pear glochid ocular surface injury is not uncommon in the region during summer, it should be considered in patient with eye pain during that period. Farmers who are in close contact with prickly pears should use protective eyeglasses and gloves. PMID:24669148

  14. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests.

    PubMed

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2015-09-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%).

  15. Characterization of new eye drops with choline salicylate and assessment of their irritancy by in vitro short time exposure tests

    PubMed Central

    Wroblewska, Katarzyna; Kucinska, Małgorzata; Murias, Marek; Lulek, Janina

    2014-01-01

    The aim of our study was to examine the irritation potential of new eye drops containing 2% choline salicylate (CS) as an active pharmaceutical ingredient (API) and various polymers increasing eye drop viscosity (hydroxyethylcellulose, hydroxypropyl methylcellulose, methylcellulose, polyvinyl alcohol, polyvinylpyrrolidone). The standard method for assessing the potential of irritating substances has been the Draize rabbit eye test. However the European Centre for Validation of Alternative Methods and the Coordinating Committee for Validation of Alternative Methods recommend, short time exposure (STE) in vitro tests as an alternative method for assessing eye irritation. The eye irritation potential was determined using cytotoxicity test methods for rabbit corneal cell line (SIRC) after 5 min exposure. The viability of cells was determined using two cytotoxicity assays: MTT and Neutral Red Uptake. According to the irritation rankings for the short time exposure test, all tested eye drops are classified as non-irritating (cell viability >70%). PMID:27134543

  16. Does instruction to eliminate coffee, tea, alcohol, carbonated, and artificially sweetened beverages improve lower urinary tract symptoms: A Prospective Trial

    PubMed Central

    Miller, Janis M.; Garcia, Caroline E.; Hortsch, Sarah Becker; Guo, Ying; Schimpf, Megan O.

    2016-01-01

    Purpose Common advice for lower urinary tract symptoms (LUTS) of frequency, urgency and related bother includes elimination of potentially irritating beverages (coffee, tea, alcohol, and carbonated and/or artificially sweetened beverages). The purpose of this study was to determine compliance with standardized instruction to eliminate these potentially irritating beverages, whether LUTS improved after instruction, and if symptoms worsened with partial reintroduction. Design The three-phase fixed sequence design was: 1) baseline, 2) eliminate potentially irritating beverages listed above, and 3) reintroduce at 50% of baseline volume, with a washout period between each 3-day phase. We asked participants to maintain total intake volume by swapping in equal amounts of non-potentially irritating beverages (primarily water). Subjects and Setting The study sample comprised 30 community-dwelling women recruited through newspaper advertisement. Methods Quantification measures included 3-day voiding diaries and detailed beverage intake, and LUTS questionnaires completed during each phase. Results During Phase 2, we found significant reduction in potentially irritating beverages but complete elimination was rare. Despite the protocol demands, total beverage intake was not stable; mean (± standard deviation) daily total intake volume dropped by 6.2±14.9oz (p=0.03) during Phase 2. In Phase 3, the volume of total beverage intake returned to baseline, but intake of potentially irritating beverages also returned to near baseline rather than 50% as requested by protocol. Despite this incomplete adherence to study protocols, women reported reduction in symptoms of urge, inability to delay voiding, and bother during both phases (p≤0.01). The number of voids per day decreased on average by 1.3 and 0.9 voids during phases 2 and 3 respectively (p=0.002 and p=0.035). Conclusions Education to reduce potentially irritating beverages resulted in improvement in LUTS. However, eliminating potentially irritating beverages was difficult to achieve and maintain. Study findings do not allow us to determine if LUTS improvement was attributable to intake of fewer potentially irritating beverages, reduced intake of all beverages, the effect of self-monitoring, or some combination of these factors. PMID:26727685

  17. Assessment of the in vitro dermal irritation potential of cerium, silver, and titanium nanoparticles in a human skin equivalent model

    EPA Science Inventory

    AbstractDermal exposure to metals may res·ult in irritant contact dermatitis. This study examined the potential of metal nanoparticles to elicit irritant contact dermatitis in a human skin equivalent model (HSEM) derived from epidermal keratinocytes. These cultured cells form a m...

  18. In vivo acute toxicological studies of an antioxidant extract from Mangifera indica L. (Vimang).

    PubMed

    Garrido, Gabino; Rodeiro, Idania; Hernández, Ivones; García, Gastón; Pérez, Gema; Merino, Nelson; Núñez-Sellés, Alberto; Delgado, René

    2009-01-01

    Mango (Mangifera indica L.) stem bark aqueous extract (MSBE) is a natural product with antioxidant, anti-inflammatory, analgesic, and immunomodulatory effects. Its formulations (e.g., tablets, capsules, syrup, vaginal oval, and suppositories) are known by the brand name of Vimang. In view of the ethnomedical, preclinical, and clinical uses of this extract and the necessity to assess its possible toxicological effect on man, a toxicological analysis of a standard extract is reported in this paper. Acute toxicity was evaluated in mice and rats by oral, dermal, and intraperitoneal (i.p.) administration. The extract, by oral or dermal administration, showed no lethality at the limit doses of 2,000 mg/kg body weight and no adverse effects were found. Deaths occurred with the i.p. administration at 200, but not 20 mg/kg in mice. MSBE was also studied on irritant tests in rabbits, and the results showed that it was nonirritating on skin, ocular, or rectal mucosa. The extract had minimal irritancy following vaginal application.

  19. Corneal Sensitivity Following Lacrimal Gland Excision in the Rat

    PubMed Central

    Meng, Ian D.; Barton, Stephen T.; Mecum, Neal E.; Kurose, Masayuki

    2015-01-01

    Purpose. Dry eye disease (DED) produces ocular pain and irritation, yet a detailed characterization of ocular sensitivity in a preclinical model of DED is lacking. The aim of the present study was to assess nociceptive behaviors in an aqueous tear deficiency model of DED in the rat. Methods. Spontaneous blinking, corneal mechanical thresholds, and eye wipe behaviors elicited by hypertonic saline (5.0 M) were examined over a period of 8 weeks following the unilateral excision of either the exorbital lacrimal gland or of the exorbital and infraorbital lacrimal glands, and in sham surgery controls. The effect of topical proparacaine on spontaneous blinking and of systemic morphine (0.5–3.0 mg/kg, subcutaneous [SC]) on spontaneous blinking and eye wipe responses were also examined. Results. Lacrimal gland excision resulted in mechanical hypersensitivity and an increase in spontaneous blinking in the ipsilateral eye over an 8-week period that was more pronounced after infra- and exorbital gland excision. The time spent eye wiping was also enhanced in response to hypertonic saline (5.0 M) at both 1- and 8-week time-points, but only in infra- and exorbital gland excised animals. Morphine attenuated spontaneous blinking, and the response to hypertonic saline in dry eye animals and topical proparacaine application reduced spontaneous blinking down to control levels. Conclusions. These results indicate that aqueous tear deficiency produces hypersensitivity in the rat cornea. In addition, the increase in spontaneous blinks and their reduction by morphine and topical anesthesia indicate the presence of persistent irritation elicited by the activation of corneal nociceptors. PMID:26024120

  20. Does Instruction to Eliminate Coffee, Tea, Alcohol, Carbonated, and Artificially Sweetened Beverages Improve Lower Urinary Tract Symptoms?: A Prospective Trial.

    PubMed

    Miller, Janis M; Garcia, Caroline E; Hortsch, Sarah Becker; Guo, Ying; Schimpf, Megan O

    2016-01-01

    Common advice for lower urinary tract symptoms (LUTS) such as frequency, urgency, and related bother includes elimination of potentially irritating beverages (coffee, tea, alcohol, and carbonated and/or artificially sweetened beverages). The purpose of this study was to determine compliance with standardized instruction to eliminate these potentially irritating beverages, whether LUTS improved after instruction, and whether symptoms worsened with partial reintroduction. The 3-phase fixed sequence design was (1) baseline, (2) eliminate potentially irritating beverages listed above, and (3) reintroduce at 50% of baseline volume, with a washout period between each 3-day phase. We asked participants to maintain total intake volume by swapping in equal amounts of nonpotentially irritating beverages (primarily water). The study sample comprised 30 community-dwelling women recruited through newspaper advertisement. Quantification measures included 3-day voiding diaries and detailed beverage intake, and LUTS questionnaires completed during each phase. During Phase 2, we found significant reduction in potentially irritating beverages but complete elimination was rare. Despite protocol demands, total beverage intake was not stable; mean (± standard deviation) daily total intake volume dropped by 6.2 ± 14.9 oz (P = .03) during Phase 2. In Phase 3, the volume of total beverage intake returned to baseline, but the intake of potentially irritating beverages also returned to near baseline rather than 50% as requested by protocol. Despite this incomplete adherence to study protocols, women reported reduction in symptoms of urge, inability to delay voiding, and bother during both phases (P ≤ .01). The number of voids per day decreased on average by 1.3 and 0.9 voids during Phases 2 and 3, respectively (P = .002 and P = .035). Education to reduce potentially irritating beverages resulted in improvement in LUTS. However, eliminating potentially irritating beverages was difficult to achieve and maintain. Study findings do not allow us to determine whether LUTS improvement was attributable to intake of fewer potentially irritating beverages, reduced intake of all beverages, the effect of self-monitoring, or some combination of these factors.

  1. Ocular surface and tear functions after topical cyclosporine treatment in dry eye patients with chronic graft-versus-host disease.

    PubMed

    Wang, Y; Ogawa, Y; Dogru, M; Kawai, M; Tatematsu, Y; Uchino, M; Okada, N; Igarashi, A; Kujira, A; Fujishima, H; Okamoto, S; Shimazaki, J; Tsubota, K

    2008-02-01

    We investigated the effect of 0.05% topical cyclosporine (Cys) on the ocular surface and tear functions in dry eye patients with chronic GVHD (cGVHD) in a prospective comparative study. Thirty eyes of 15 patients refractory to baseline treatment were recruited and the patients assigned for topical Cys treatment group (14 eyes of 7 patients) and control group (12 eyes of 6 patients) respectively. Two patients dropped out because of intolerable irritation while using topical Cys eye drops. Visual analog scale symptom scores, corneal sensitivity, Schirmer I test value, tear film break-up time (TBUT), tear evaporation rate and ocular surface vital staining scores were recorded at baseline and at the end of the following one month. Conjunctival impression and brush cytology were performed before and after the treatment. After topical Cys treatment, significant improvements were found in symptom scores, corneal sensitivity, tear evaporation rate, TBUT, vital staining scores, goblet cells density, conjunctival squamous metaplasia grade, inflammatory cell numbers and the MUC5AC expression. Our study suggests that 0.05% topical Cys may be an effective treatment for dry eye patients with cGVHD. The improvements in the ocular surface and tear functions resulted presumably from the decreased inflammation, increased goblet cell density and MUC5AC mRNA expression. Bone Marrow Transplantation (2008) 41, 293-302; doi:10.1038/sj.bmt.1705900; published online 5 November 2007.

  2. Computer vision syndrome: A review.

    PubMed

    Gowrisankaran, Sowjanya; Sheedy, James E

    2015-01-01

    Computer vision syndrome (CVS) is a collection of symptoms related to prolonged work at a computer display. This article reviews the current knowledge about the symptoms, related factors and treatment modalities for CVS. Relevant literature on CVS published during the past 65 years was analyzed. Symptoms reported by computer users are classified into internal ocular symptoms (strain and ache), external ocular symptoms (dryness, irritation, burning), visual symptoms (blur, double vision) and musculoskeletal symptoms (neck and shoulder pain). The major factors associated with CVS are either environmental (improper lighting, display position and viewing distance) and/or dependent on the user's visual abilities (uncorrected refractive error, oculomotor disorders and tear film abnormalities). Although the factors associated with CVS have been identified the physiological mechanisms that underlie CVS are not completely understood. Additionally, advances in technology have led to the increased use of hand-held devices, which might impose somewhat different visual challenges compared to desktop displays. Further research is required to better understand the physiological mechanisms underlying CVS and symptoms associated with the use of hand-held and stereoscopic displays.

  3. Corneal Neovascularization with Associated Lipid Keratopathy in a Patient with Obstructive Sleep Apnea-Hypopnea Syndrome Using a Continuous Positive Airway Pressure Machine.

    PubMed

    Oikonomakis, Konstantinos; Petrelli, Myrsini; Andreanos, Konstantinos; Mouchtouris, Andreas; Petrou, Petros; Georgalas, Ilias; Papaconstantinou, Dimitrios; Kymionis, George

    2017-01-01

    To report a case of corneal neovascularization with secondary lipid keratopathy in a patient treated with continuous positive airway pressure (CPAP) for obstructive sleep apnea-hypopnea syndrome (OSAHS). A 49-year-old male had been diagnosed with obstructive sleep apnea syndrome 10 years ago and has been treated with the application of a CPAP machine during night sleep ever since. For the past year, the patient had been complaining for ocular irritation and excessive tearing of the left eye on awakening. Slit-lamp biomicroscopy revealed the presence of neovascularization and lipid exudation in the inferior third of the cornea of the left eye. Ocular patching during night sleep resulted in recession of the reported symptoms and shrinkage of the neovascularization, while the area of lipid exudation ceased to enlarge. To the best of our knowledge, this is the first report of corneal neovascularization in a patient using a CPAP machine for OSAHS.

  4. High-precision piezo-ejection ocular microdosing: Phase II study on local and systemic effects of topical phenylephrine.

    PubMed

    Ianchulev, Tsontcho; Weinreb, Robert; Tsai, James C; Lin, Shan; Pasquale, Louis R

    2018-01-01

    Conventional eyedropper-delivered volumes (25-50 µl) exceed the eye's usual tear-film volume (7 µl) and precorneal reservoir capacity, risking overflow and ocular/systemic complications. Piezoelectric high-precision microdosing may circumvent these limitations. Results & methodology: In this masked, nonrandomized, cross-over study, subjects (n = 12) underwent pupil dilation with topical phenylephrine (PE) administered by 32-µl eyedropper (2.5% or 10% formulation) and 8-µl electronic microdosing (10% formulation). Microdosing with PE-10% achieved comparable peak dilation as 10% eyedropper-delivery and superior dilation to 2.5% eyedropper-delivery (p = 0.009) at 75 min. Microdosing significantly reduced 20-min plasma PE levels versus PE10% eyedropper; neither treatment altered heart rate/blood pressure. Eye irritation occurred significantly less frequently with microdosing than PE10% eyedrops. Piezo-ejection PE microdosing achieves comparable biological effect as eyedropper dosing; reduced systemic absorption may decrease risk of systemic side effects.

  5. Mechanisms Involved in Injury and Repair of the Murine Lacrimal Gland: Role of Programmed Cell Death and Mesenchymal Stem Cells

    PubMed Central

    Zoukhri, Driss

    2011-01-01

    The non-keratinized epithelia of the ocular surface are constantly challenged by environmental insults, such as smoke, dust, and airborne pathogens. Tears are the sole physical protective barrier for the ocular surface. Production of tears in inadequate quantity or of inadequate quality results in constant irritation of the ocular surface, leading to dry eye disease, also referred to as keratoconjunctivitis sicca (KCS). Inflammation of the lacrimal gland, such as occurs in Sjögren’s syndrome, sarcoidosis, chronic graft versus-host disease, and other pathological conditions, results in inadequate secretion of the aqueous layer of the tear film, and is a leading cause of dry eye disease. The hallmarks of lacrimal gland inflammation are the presence of immune cell infiltrates, loss of acinar epithelial cells (the secreting cells), and increased production of proinflammatory cytokines. To date, the mechanisms leading to acinar cell loss and the associated decline in lacrimal gland secretion are still poorly understood. It is also not understood why the remaining lacrimal gland cells are unable to proliferate in order to regenerate a functioning lacrimal gland. This article reviews recent advances in exocrine tissue injury and repair, with emphasis on the roles of programmed cell death and stem/progenitor cells. PMID:20427009

  6. Design and evaluation of novel fast forming pilocarpine-loaded ocular hydrogels for sustained pharmacological response

    PubMed Central

    Anumolu, SivaNaga S.; Singh, Yashveer; Gao, Dayuan; Stein, Stanley; Sinko, Patrick J.

    2009-01-01

    Fast forming hydrogels prepared by crosslinking a poly(ethylene glycol) (PEG)-based copolymer containing multiple thiol (SH) groups were evaluated for the controlled ocular delivery of pilocarpine and subsequent pupillary constriction. Physical properties of the hydrogels were characterized using UV-Vis spectrophotometry, transmission electron microscopy (TEM), rheometry, and swelling kinetics. Pilocarpine loading efficiency and release properties were measured in simulated tear fluid. The hydrogel formulations exhibited high drug loading efficiency (~74%). Pilocarpine release was found to be biphasic with release half times of ~2 and 94 h, respectively, and 85–100% of the drug was released over 8-days. Pilocarpine-loaded (2% w/v) hydrogels were evaluated in a rabbit model and compared to a similar dose of drug in aqueous solution. The hydrogels were retained in the eye for the entire period of the study with no observed irritation. Pilocarpine-loaded hydrogels sustained pupillary constriction for 24 h after administration as compared to 3 h for the solution, an 8-fold increase in duration of action. A strong correlation between pilocarpine release and pupillary response was observed. In conclusion, the current studies demonstrate that in situ forming PEG hydrogels possess the viscoelastic, retention, and sustained delivery properties required for an efficient ocular drug delivery system. PMID:19341773

  7. Application of Box-Behnken design for preparation of levofloxacin-loaded stearic acid solid lipid nanoparticles for ocular delivery: Optimization, in vitro release, ocular tolerance, and antibacterial activity.

    PubMed

    Baig, Mirza Salman; Ahad, Abdul; Aslam, Mohammed; Imam, Syed Sarim; Aqil, Mohd; Ali, Asgar

    2016-04-01

    The aim of the present study was to develop and optimize levofloxacin loaded solid lipid nanoparticles for the treatment of conjunctivitis. Box-Behnken experimental design was applied for optimization of solid lipid nanoparticles. The independent variables were stearic acid as lipid (X1), Tween 80 as surfactant (X2) and sodium deoxycholate as co-surfactant (X3) while particle size (Y1) and entrapment efficiency (Y2) were the dependent variables. Further in vitro release and antibacterial activity in vitro were also performed. The optimized formulation of levofloxacin provides particle size of 237.82 nm and showed 78.71% entrapment efficiency and achieved flux 0.2,493 μg/cm(2)/h across excised goat cornea. In vitro release study showed prolonged drug release from the optimized formulation following Korsmeyer-Peppas model. Antimicrobial study revealed that the developed formulation possesses antibacterial activity against Staphylococcus aureus, and Escherichia coli equivalent to marketed eye drops. HET-CAM test demonstrated that optimized formulation was found to be non-irritant and safe for topical ophthalmic use. Our results concluded that solid lipid nanoparticles are an efficient carrier for ocular delivery of levofloxacin and other drugs. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Dorzolamide-loaded PLGA/vitamin E TPGS nanoparticles for glaucoma therapy: Pharmacoscintigraphy study and evaluation of extended ocular hypotensive effect in rabbits.

    PubMed

    Warsi, Musarrat H; Anwar, Mohammed; Garg, Vaidehi; Jain, Gaurav K; Talegaonkar, Sushama; Ahmad, Farhan J; Khar, Roop K

    2014-10-01

    Poor drug penetration and rapid clearance after topical instillation of a drug formulation into the eyes are the major causes for the lower ocular bioavailability from conventional eye drops. Along with this, poor encapsulation efficiency of hydrophilic drug in polymeric nanoparticles remains a major formulation challenge. Taking this perspective into consideration, dorzolamide (DZ)-loaded PLGA nanoparticles were developed employing two different emulsifiers (PVA and vitamin E TPGS) and the effects of various formulation and process variables on particle size and encapsulation efficiency were assessed. Nanoparticles emulsified with vitamin E TPGS (DZ-T-NPs) were found to possess enhanced drug encapsulation (59.8±6.1%) as compared to those developed with PVA as emulsifier (DZ-P-NPs). Transcorneal permeation study revealed a significant enhancement in permeation (1.8-2.5 fold) as compared to solution. In addition, ex vivo biodistribution study showed a higher concentration of drug in the aqueous humour (1.5-2.3 fold). Histological and IR-camera studies proved the non-irritant potential of the formulations. Pharmacoscintigraphic studies revealed the reduced corneal clearance, as well as naso-lachrymal drainage in comparison to drug solution. Furthermore, efficacy study revealed that DZ-P-NPs and DZ-T-NPs significantly reduced the intraocular pressure by 22.81% and 29.12%, respectively, after a single topical instillation into the eye. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Hydrophilic Dogwood Extracts as Materials for Reducing the Skin Irritation Potential of Body Wash Cosmetics.

    PubMed

    Nizioł-Łukaszewska, Zofia; Osika, Paweł; Wasilewski, Tomasz; Bujak, Tomasz

    2017-02-19

    A significant problem related to the use of surfactants in body wash cosmetics is their propensity to trigger skin irritations. Only scarce literature exists on the effect of plant extracts on the skin irritation potential. The present study is an attempt to determine the effect of hydrophilic dogwood extracts on the irritant potential of body wash gels. Extractants used in the study were water and mixtures of water with glycerine, water with trimethylglycine (betaine), and water with plant-derived glycol (propanediol). The basic biochemical properties, i.e., the ability to neutralize free radicals, and the content of polyphenols, anthocyanins and flavonoids, were determined. An attempt was undertaken to analyze the impact of the extract added to natural body wash gel formulations on product properties. The skin irritation potential was assessed by determining the zein number and the increase in the pH level of the bovine serum albumin (BSA) solution. The viscosity and foaming ability of the resulting products were evaluated. The studies revealed that an addition of dogwood extract contributes to an improvement in the properties of body wash gels and significantly increases the safety of product use through reducing the skin irritation effect.

  10. The identification and classification of skin irritation hazard by a human patch test.

    PubMed

    Basketter, D A; Whittle, E; Griffiths, H A; York, M

    1994-08-01

    There exist various regulatory instruments the purpose of which is to ensure that the intrinsic toxic hazards associated with substances and preparations are identified. In the context of identification of skin irritation potential, the method is normally the Draize test. Guidance notes provided by the OECD and the EEC expect that corrosive substances will have been screened out by a variety of methods. Substances or preparations which cause a sufficient degree of skin irritation will be classified as skin irritants. The primary motivation behind the present work was to introduce the concept that it is possible to assess the hazard potential of a substance or preparation to produce skin irritation in a human study. In the example presented here, 20% sodium lauryl sulfate (SLS) has been chosen as the positive control. With the protocol currently devised, occluded patch treatment with 20% SLS for up to 4 hr produces an irritant response in just over half of the panel. An irritant response is taken as a clinically evident and significant increase in erythema, oedema or dryness--a minimum of a+ reaction on the ICDRG scale. At such a level of response with the positive control (both in terms of intensity and in proportion of the panel), it is then possible to judge and/or to determine statistically, whether the test material has produced a level of skin irritation which is similar to, greater, or lower than the positive control. In this way a human patch test protocol can form a fundamental component of a strategy for the replacement of animals in determination of skin irritation and corrosion potential. By use of a careful and progressive protocol and by comparison of test data against a positive control it is both possible and practical to classify substances and preparations in terms of their skin irritation potential using that endpoint in the species of concern, man.

  11. [Randomly sampling survey of dry eye awareness in general eye clinic].

    PubMed

    Qiu, Wei-qiang; Liu, Zi-yuan; Ji, Jing; Zeng, Lin; Li, Xue-min; Wang, Wei

    2013-03-01

    To determine the dry eye awareness in the populations visiting general eye clinic. This was a cross-sectional study. A questionnaire about dry eye was designed and administrated to Peking University Third Hospital General Eye Clinic patients (n = 804) from June 2010 to June 2011. The questionnaire contents included general demographic characteristics, experience of health-related work, past medical history, medication history and ocular surface symptoms associated with dry eye, contact lens wearing, ocular operation history, etc. Chi-square and Binary logistic regression analysis was used to determine the influence of demographic and clinical features on awareness of dry eye. Awareness of "dry eye" in the general eye clinical patients was relatively low (26.9%, 216/804). Participants whose age were between 40 and 60 years had better dry eye awareness (41.7%, 73/175) (χ(2) = 27.365, P = 0.000). Dry eye awareness of female was better than that of male [female: 33.8% (151/447), male: 18.2% (65/357), χ(2) = 24.500, P = 0.000]. Those who had been in health-related work (71.4%, 30/42), and whose friends or relatives were ophthalmologists (54.7%, 52/95) had better dry eye awareness (χ(2) = 31.582, 36.400; both P < 0.01). Participants with a history of rheumatoid arthritis (7/10) or diabetes mellitus (63.0%, 17/27) had better dry eye awareness (χ(2) = 32.301, 29.887;both P < 0.01). Those who had been using artificial tears (77.5%, 31/40), oral contraceptives (9/14), diuretics (10/18), sedatives (70.4%, 19/27) and anti-depression drugs (4/4) had better dry eye awareness (χ(2) = 54.928, 10.154, 7.713, 26.912, 10.943; all P < 0.01). Except frequently blinking (29.5%), participants who had ocular irrigating symptoms (all > 33.0%) had better awareness than those who had not (χ(2) = 7.831 - 32.522, all P < 0.01). Those who were allergic to environment irritating factors (all > 30.0%) had better awareness (χ(2) = 5.033 - 24.564, all P < 0.01). Participants who had medical history of ocular surgery (47.2%, 34/72), experience of wearing contact lens (33.2%, 94/283), who were diagnosed as dry eye (100.0%, 45/45) and who had regular ocular examinations (31.0%, 96/310) had better awareness (χ(2) = 4.321 - 129.763, all P < 0.01). Those who had visited general practitioners (14.8%, 16/108) had lower awareness than those who went to hospital of higher level (28.7%, 200/696) (χ(2) = 9.324, P = 0.002). The result of binary logistic regression analysis showed that gender, health-related working experience, relatives or friends working as Ophthalmologists, using artificial tears, oral contraceptives and sedatives, ocular irritations or environment sensitivity, eye surgeries and wearing contact lens were factors that affected dry eye awareness (OR > 1.000, P < 0.10). Dry eye awareness in the population who visit general eye clinic is low. The knowledge of dry eye should be added to the patient education and public popularization.

  12. Safety of a Novel Botanical Extract Formula for Ameliorating Allergic rhinitis. Part II.

    PubMed

    Amit, A; Joshua, A J; Bagchi, M; Bagchi, D

    2005-01-01

    Abstract Each year more than 50 million Americans suffer from allergic rhinitis, which is a state of hypersensitivity or hyperimmunity. Basically, allergic rhinitis is symptomatically recognized as the inflammation and irritation of the nasal mucosal membranes; sneezing; stuffy/runny nose; nasal congestion; and itchy; watery, and swollen eyes; and defined as a state of hypersensitivity/ hyperimmunity caused by exposure to a particular allergen (antigen) that results in increased reactivity upon subsequent exposure. A novel polyherbal formulation (Aller-7/NR-A2) was developed for the treatment of allergic rhinitis using a unique combination of extracts from seven medicinal plants, including Phyllanthus emblica, Terminalia chebula, Terminalia bellerica, Albizia lebbeck, Piper nigrum, Zingiber officinale, and Piper longum. Earlier studies in our laboratories have demonstrated potent antihistaminic, anti-inflammatory, antispasmodic, antioxidant, and mast-cell stabilization activities of Aller-7 in addition to its efficacy in a clinical setting. A series of preliminary toxicological evaluations were also conducted in the past, which demonstrated its safety. In this study, we have conducted further safety studies on Aller-7, including acute oral, acute dermal, acute dermal irritation, eye irritation, and 90-day repeated dose toxicity studies. Acute oral toxicity of Aller-7 was found to be greater than 5,000 mg/kg body weight in both male and female rats and no mortality or toxicity was observed at this dose, while the acute dermal toxicity was found to be greater than 2,000 mg/kg body weight. In the acute dermal irritation study, the skin irritancy index was found to be 0.0, which classifies Aller-7 as a nonirritant to rabbit skin. In the acute eye irritation study, Aller-7 was found to have minimal irritancy to eyes of rabbits. In the repeated-dose 90-day oral toxicity study, Aller-7 was administered at dose levels of 100, 300, and 1,000 mg/kg rat body weight for 90 consecutive days by oral gavage. Aller-7 did not induce any significant change in the hematological parameters. No ocular abnormalities were observed. Some minor histopathological changes were observed, but did not reveal any significant treatment-related histopathological changes. The above findings revealed that the no observed adverse effect level (NOAEL) of Aller-7 is greater than 1,000 mg/kg body weight. Taken together, these studies demonstrate the broad spectrum safety of Aller-7.

  13. Isolation of the ocular surface to treat dysfunctional tear syndrome associated with computer use.

    PubMed

    Yee, Richard W; Sperling, Harry G; Kattek, Ashballa; Paukert, Martin T; Dawson, Kevin; Garcia, Marcie; Hilsenbeck, Susan

    2007-10-01

    Dysfunctional tear syndrome (DTS) associated with computer use is characterized by mild irritation, itching, redness, and intermittent tearing after extended staring. It frequently involves foreign body or sandy sensation, blurring of vision, and fatigue, worsening especially at the end of the day. We undertook a study to determine the effectiveness of periocular isolation using microenvironment glasses (MEGS) alone and in combination with artificial tears in alleviating the symptoms and signs of dry eye related to computer use. At the same time, we evaluated the relative ability of a battery of clinical tests for dry eye to distinguish dry eyes from normal eyes in heavy computer users. Forty adult subjects who used computers 3 hours or more per day were divided into dry eye sufferers and controls based on their scores on the Ocular Surface Disease Index (OSDI). Baseline scores were recorded and ocular surface assessments were made. On four subsequent visits, the subjects played a computer game for 30 minutes in a controlled environment, during which one of four treatment conditions were applied, in random order, to each subject: 1) no treatment, 2) artificial tears, 3) MEGS, and 4) artificial tears combined with MEGS. Immediately after each session, subjects were tested on: a subjective comfort questionnaire, tear breakup time (TBUT), fluorescein staining, lissamine green staining, and conjunctival injection. In this study, a significant correlation was found between cumulative lifetime computer use and ocular surface disorder, as measured by the standardized OSDI index. The experimental and control subjects were significantly different (P<0.05) in the meibomian gland assessment and TBUT; they were consistently different in fluorescein and lissamine green staining, but with P>0.05. Isolation of the ocular surface alone produced significant improvements in comfort scores and TBUT and a consistent trend of improvement in fluorescein staining and lissamine green staining. Isolation plus tears produced a significant improvement in lissamine green staining. The subjective comfort inventory and the TBUT test were most effective in distinguishing between the treatments used. Computer users with ocular surface complaints should have a detailed ocular surface examination and, if symptomatic, they can be effectively treated with isolation of the ocular surface, artificial tears therapy, and effective environmental manipulations.

  14. Tolerability of loteprednol/tobramycin versus dexamethasone/tobramycin in healthy volunteers: results of a 4-week, randomized, double-masked, parallel-group study.

    PubMed

    Bartlett, Jimmy D; Holland, Edward J; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L

    2008-08-01

    To compare the ocular comfort and tolerability of loteprednol etabonate 0.5%/tobramycin 0.3% (LE/T; Zylet) with dexamethasone 0.1%/tobramycin 0.3% (DM/T; TobraDex) in healthy volunteers. In this multicenter, randomized, double-masked, parallel-group study, healthy volunteers (n = 306) were randomized to receive LE/T or DM/T four times per day for 28 days. Subjects recorded subjective ratings for seven comfort/tolerability parameters using an electronic patient diary (EPD). The primary endpoint was the difference at week 4 from the ratings of an artificial tear at baseline in comfort/tolerability parameters between treatment groups, using a noninferiority paradigm. ClinicalTrials. gov, NCT 00532961. The 97.5% confidence intervals for the lower bound were within -10 for all of the seven comfort/ tolerability parameters evaluated (pain, stinging/burning, irritation, itchiness, foreign-body sensation, dryness, and light sensitivity). Secondary analysis revealed small but significant within-treatment differences in pain favoring LE/T over tears and in light sensitivity favoring tears over DM/T (p < 0.01). Small between-treatment differences in the changes from baseline tear ratings to individual study visits favored LE/T for pain, stinging/burning, irritation, itchiness, foreign-body sensation, and light sensitivity at visit 4 (p < or = 0.04); for pain, stinging/burning, and foreignbody sensation at visit 5 (p < or = 0.03), and for dryness and light sensitivity at visit 6 (p < or = 0.05). LE/T satisfied all conditions of noninferiority to DM/T in comfort and tolerability. Subjects receiving LE/T were more likely to report better ocular comfort/tolerability ratings relative to baseline artificial tears than subjects receiving DM/T. The study population consisted of healthy volunteers.

  15. In vitro assessment of skin irritation potential of surfactant-based formulations by using a 3-D skin reconstructed tissue model and cytokine response.

    PubMed

    Walters, Russel M; Gandolfi, Lisa; Mack, M Catherine; Fevola, Michael; Martin, Katharine; Hamilton, Mathew T; Hilberer, Allison; Barnes, Nicole; Wilt, Nathan; Nash, Jennifer R; Raabe, Hans A; Costin, Gertrude-Emilia

    2016-12-01

    The personal care industry is focused on developing safe, more efficacious, and increasingly milder products, that are routinely undergoing preclinical and clinical testing before becoming available for consumer use on skin. In vitro systems based on skin reconstructed equivalents are now established for the preclinical assessment of product irritation potential and as alternative testing methods to the classic Draize rabbit skin irritation test. We have used the 3-D EpiDerm™ model system to evaluate tissue viability and primary cytokine interleukin-1α release as a way to evaluate the potential dermal irritation of 224 non-ionic, amphoteric and/or anionic surfactant-containing formulations, or individual raw materials. As part of our testing programme, two representative benchmark materials with known clinical skin irritation potential were qualified through repeated testing, for use as references for the skin irritation evaluation of formulations containing new surfactant ingredients. We have established a correlation between the in vitro screening approach and clinical testing, and are continually expanding our database to enhance this correlation. This testing programme integrates the efforts of global manufacturers of personal care products that focus on the development of increasingly milder formulations to be applied to the skin, without the use of animal testing. 2016 FRAME.

  16. Emulsion of Chloramphenicol: an Overwhelming Approach for Ocular Delivery.

    PubMed

    Ashara, Kalpesh C; Shah, Ketan V

    2017-03-01

    Ophthalmic formulations of chloramphenicol have poor bioavailability of chloramphenicol in the ocular cavity. The present study aimed at exploring the impact of different oil mixtures in the form of emulsion on the permeability of chloramphenicol after ocular application. Selection of oil mixture and ratio of the components was made by an equilibrium solubility method. An emulsifier was chosen according to its emulsification properties. A constrained simplex centroid design was used for the assessment of the emulsion development. Emulsions were evaluated for physicochemical properties; zone of inhibition, in-vitro diffusion and ex-vivo local accumulation of chloramphenicol. Validation of the design using check-point batch and reduced polynomial equations were also developed. Optimization of the emulsion was developed by software Design® expert 6.0.8. Assessment of the osmolarity, ocular irritation, sterility testing and isotonicity of optimized batch were also made. Parker Neem®, olive and peppermint oils were selected as an oil phase in the ratio 63.64:20.2:16.16. PEG-400 was selected as an emulsifier according to a pseudo-ternary phase diagram. Constrained simplex-centroid design was applied in the range of 25-39% water, 55-69% PEG-400, 5-19% optimized oil mixture, and 1% chloramphenicol. Unpaired Student's t-test showed for in-vitro and ex-vivo studies that there was a significant difference between the optimized batch of emulsion and Chloramphenicol eye caps (a commercial product) according to both were equally safe. The optimized batch of an emulsion of chloramphenicol was found to be as safe as and more effective than Chloramphenicol eye caps.

  17. TFOS DEWS II pain and sensation report

    PubMed Central

    Belmonte, Carlos; Nichols, Jason J.; Cox, Stephanie M.; Brock, James A.; Begley, Carolyn G.; Bereiter, David A.; Dartt, Darlene A.; Galor, Anat; Hamrah, Pedram; Ivanusic, Jason J.; Jacobs, Deborah S.; McNamara, Nancy A.; Rosenblatt, Mark I.; Stapleton, Fiona; Wolffsohn, James S.

    2017-01-01

    Pain associated to mechanical and chemical irritation of the eye surface is mediated by trigeminal ganglia mechano- and polymodal nociceptor neurons while cold thermoreceptors detect wetness and reflexly maintain basal tear production and blinking rate. These neurons project into two regions of the trigeminal brain stem nuclear complex: ViVc, activated by changes in the moisture of the ocular surface and VcC1, mediating sensory-discriminative aspects of ocular pain and reflex blinking. ViVc ocular neurons project to brain regions that control lacrimation and spontaneous blinking and to the sensory thalamus. Secretion of the main lacrimal gland is regulated dominantly by autonomic parasympathetic nerves, reflexly activated by eye surface sensory nerves. These also evoke goblet cell secretion through unidentified efferent fibers. Neural pathways involved in the regulation of Meibonian gland secretion or mucins release have not been identified. In dry eye disease, reduced tear secretion leads to inflammation and peripheral nerve damage. Inflammation causes sensitization of polymodal and mechano-nociceptor nerve endings and an abnormal increase in cold thermoreceptor activity, altogether evoking dryness sensations and pain. Long-term inflammation and nerve injury alter gene expression of ion channels and receptors at terminals and cell bodies of trigeminal ganglion and brainstem neurons, changing their excitability, connectivity and impulse firing. Perpetuation of molecular, structural and functional disturbances in ocular sensory pathways ultimately leads to dysestesias and neuropathic pain referred to the eye surface. Pain can be assessed with a variety of questionaires while the status of corneal nerves is evaluated with esthesiometry and with in vivo confocal microscopy. PMID:28736339

  18. Meta-analysis of the Efficacy and Safety of Latanoprost Monotherapy in Patients With Angle-closure Glaucoma.

    PubMed

    Chen, Ru; Yang, Ke; Zheng, Zhong; Ong, Moh-Lim; Wang, Ning-Li; Zhan, Si-Yan

    2016-03-01

    To systematically evaluate the safety and efficacy of latanoprost monotherapy for the treatment of patients with angle-closure glaucoma. We searched EMBASE, Medline, Cochrane Library, Chinese Journal Full-text Database (CNKI), Chinese Science and Technology Periodical Database (VIP), and Wang Fang using the search terms "latanoprost" (or its commercial name, Xalatan) and "angle-closure glaucoma." Resulting articles were then screened using preset inclusion criteria. Subgroup and sensitivity analyses were performed to evaluate the impact of research population, research type (blinded or controlled), and withdrawal/loss to follow-up. A total of 17 studies (n=807) were included in this meta-analysis. The primary outcome measure was intraocular pressure (IOP). Changes in the mean, peak, and trough IOP from baseline were used as effect measures. As I statistic revealed statistical heterogeneity, the random-effects model was applied. With the exception of 2 non-Asian populations from Australia and Peru, all 13 countries included in this study were from Asia. Latanoprost reduced mean IOP by 7.9 mm Hg (32.4%), peak IOP by 7.4 mm Hg (29.8%), and trough IOP by 7.9 mm Hg (32.5%). The most frequent ocular adverse effects were ocular hyperemia, discomfort (including eye irritation, ocular discomfort, foreign body sensation, and itching), and blurred vision with a total incidence rate of 9.4%, 8.7%, and 5.2%, respectively. Systemic adverse effects encompass rhinitis, dizziness, headache, and nonspecific skin pigmentation. Latanoprost is effective at reducing the IOP of patients with angle-closure glaucoma. Adverse reactions associated with latanoprost were mainly ocular in nature.

  19. The irritation potential and reservoir effect of mild soaps.

    PubMed

    Lodén, Marie; Buraczewska, Izabela; Edlund, Fredrik

    2003-08-01

    Identification and reduction of external noxious factors is one key point in the strategy for the treatment and reduction of contact dermatitis. A wide variety of soaps on the market are claimed to be suitable for the use on sensitive skin due to their mildness. The aim of the present study was to illustrate possible differences in the irritation potential of 8 products and to investigate whether surfactant residues may form an irritant reservoir on the skin. The study was double-blind, randomized using healthy human volunteers. The inherent capacity of the products to induce irritation was determined using conventional patch test technique, whereas detection of potential surfactant residues on the skin was done using a methodology developed in the 1960s for detection of the corticosteroid reservoir in the stratum corneum. The method comprised the release of active substance from the stratum corneum reservoir by occlusion of the skin with an aluminium chamber, followed by evaluation of the biological response. In the present study, the soap-treated area was rinsed with water and then occluded. Instrumental measurements of the transepidermal water loss and superficial skin blood flow served as indicators of the injurious effects of the products. The results showed large differences in irritation potential between the products, and some of them demonstrated considerable damaging effect. Moreover, the study proved the presence of barrier-impairing residues on the skin after rinsing with water. Subclinical skin damage can make the skin vulnerable to further irritation and delay recovery of chronic irritant contact dermatitis.

  20. Final report on the safety assessment of triacetin.

    PubMed

    Fiume, Monice Zondlo

    2003-01-01

    Triacetin, also known as Glyceryl Triacetate, is reported to function as a cosmetic biocide, plasticizer, and solvent in cosmetic formulations, at concentrations ranging from 0.8% to 4.0%. It is a commonly used carrier for flavors and fragrances. Triacetin was affirmed as a generally recognized as safe (GRAS) human food ingredient by the Food and Drug Administration (FDA). Triacetin was not toxic to animals in acute oral or dermal exposures, nor was it toxic in short-term inhalation or parenteral studies, and subchronic feeding and inhalation studies. Triacetin was, at most, slightly irritating to guinea pig skin. However, in one study, it caused erythema, slight edema, alopecia, and desquamation, and did cause some irritation in rabbit eyes. Triacetin was not sensitizing in guinea pigs. Triacetin was not an irritant or a sensitizer in a clinical maximization study, and only very mild reactions were seen in a Duhring-chamber test using a 50% dilution. In humans, Triacetin reportedly has caused ocular irritation but no injury. Triacetin was not mutagenic. Although there were no available reproductive and developmental toxicity data, Triacetin was quickly metabolized to glycerol and acetic acid and these chemicals were not developmental toxins. Reports of 1,2-glyceryl diesters, which may be present in Triacetin, affecting cell growth and proliferation raised the possibility of hyperplasia and/or tumor promotion. The Cosmetic Ingredient Review (CIR) Expert Panel concluded, however, that the effects of 1,2-glyceryl diesters on cell growth and proliferation require longer ester chains on the glycerin backbone than are present when acetic acid is esterified with glycerin, as in Triacetin. On the basis of the available information, the CIR Expert Panel concluded that Triacetin is safe as used in cosmetic formulations.

  1. Potential allergy and irritation incidents among health care workers.

    PubMed

    Alamgir, Hasanat; Yu, Shicheng; Chavoshi, Negar; Ngan, Karen

    2008-07-01

    This study describes the types, causes, and outcomes of potential irritation and allergy incidents among workers in British Columbia's health care industry. Data on occupation-induced allergy and irritation incidents were extracted from a standardized database using the number of productive hours obtained from payroll data as a denominator during a 1-year period from three British Columbia health regions. Younger workers, female workers, facility support service workers, laboratory assistants and technicians, and maintenance and acute care workers were found to be at higher risk for allergy and irritation incidents. Major causes of allergy and irritation incidents included chemicals, blood and body fluids, food and objects, communicable diseases, air quality, and latex. A larger proportion of chemically induced incidents resulted in first aid care only, whereas non-chemical incidents required more emergency room visits.

  2. [Cytotoxicity of chemicals used in household products: estimation of eye irritating potency of 25 chemicals tested during 1991-1996].

    PubMed

    Ikarashi, Y; Tsuchiya, T; Nakamura, A

    1997-01-01

    Cytotoxicity potential of chemicals was evaluated by determining the concentrations inducing 50% reduction of neutral red (NR) uptake into Chinese hamster fibroblast V79 cells compared with control culture (IC50). The results of cytotoxicity test for surfactants with the data produced by the in vivo Draize eye and skin irritation test were compared. There was a good correlation between cytotoxicity and eye irritation score obtained from the Draize test. In contrast, no correlation was observed between Draize skin irritation score and cytotoxic potential of chemicals. Therefore, the NR cytotoxicity test was regarded as a possible in vitro model for predicting eye irritation. Based on the IC50 values in the NR cytotoxicity test, the eye irritation classification (weak, moderate and strong) for each chemical used in household products has been established. We evaluated the cytotoxicity of 25 chemicals used for antimicrobial, rubber accelerator, rubber antioxidant, ultraviolet absorber etc. in household products, and estimated the eye irritating potency of these test chemicals according to the criterion.

  3. Cumulative irritation potential of metronidazole gel compared to azelaic acid gel after repeated applications to healthy skin.

    PubMed

    Ziel, Kristin; Yelverton, Christopher B; Balkrishnan, Rajesh; Feldman, Steven R

    2005-01-01

    Metronidazole 0.75% gel and azelaic acid 15% gel are commonly used to treat rosacea. Irritation is a common side effect. To assess the cumulative irritation potential of metronidazole 0.75% gel and azelaic acid 15% gel. Metronidazole 0.75% gel, azelaic acid 15% gel, and a white petrolatum negative control were applied under occlusive conditions to the upper back of a total of 33 healthy subjects. There were twelve 24-hour applications (4 times a week) and three 72-hour applications on weekends during a 3-week period. Skin reactions (erythema score +/- other local reaction) were assessed within 15 to 30 minutes of removal of the products. The mean cumulative irritancy index of metronidazole 0.75% gel was significantly lower than that of azelaic acid 15% gel and not significantly higher than the negative control product. There was increasing cumulative irritancy with azelaic acid; no cumulative irritancy was seen for either metronidazole or white petrolatum. Metronidazole 0.75% gel is less irritating in sustained use than azelaic acid 15% gel.

  4. Irritancy and Allergic Responses Induced by Topical Application of ortho-Phthalaldehyde

    PubMed Central

    Anderson, Stacey E.; Umbright, Christina; Sellamuthu, Rajendran; Fluharty, Kara; Kashon, Michael; Franko, Jennifer; Jackson, Laurel G.; Johnson, Victor J.; Joseph, Pius

    2010-01-01

    Although ortho-phthalaldehyde (OPA) has been suggested as an alternative to glutaraldehyde for the sterilization and disinfection of hospital equipment, the toxicity has not been thoroughly investigated. The purpose of these studies was to evaluate the irritancy and sensitization potential of OPA. The EpiDerm Skin Irritation Test was used to evaluate in vitro irritancy potential of OPA and glutaraldehyde. Treatment with 0.4125 and 0.55% OPA induced irritation, while glutaraldehyde exposure at these concentrations did not. Consistent with the in vitro results, OPA induced irritancy, evaluated by ear swelling, when mice were treated with 0.75%. Initial evaluation of the sensitization potential was conducted using the local lymph node assay at concentrations ranging from 0.005 to 0.75%. A concentration-dependent increase in lymphocyte proliferation was observed with a calculated EC3 value of 0.051% compared to that of 0.089%, previously determined for glutaraldehyde. Immunoglobulin (Ig) E-inducing potential was evaluated by phenotypic analysis of draining lymph node (DLN) cells and measurement of total and specific serum IgE levels. The 0.1 and 0.75% exposed groups yielded significant increases in the IgE+B220+ cell population in the lymph nodes while the 0.75% treated group demonstrated significant increases in total IgE, OPA-specific IgE, and OPA-specific IgG1. In addition, significant increases in interleukin-4 messenger RNA and protein expression in the DLNs were observed in OPA-treated groups. The results demonstrate the dermal irritancy and allergic potential of OPA and raise concern about the proposed/intended use of OPA as a safe alternative to glutaraldehyde. PMID:20176622

  5. Menthol attenuates respiratory irritation responses to multiple cigarette smoke irritants

    PubMed Central

    Willis, Daniel N.; Liu, Boyi; Ha, Michael A.; Jordt, Sven-Eric; Morris, John B.

    2011-01-01

    Menthol, the cooling agent in peppermint, is added to almost all commercially available cigarettes. Menthol stimulates olfactory sensations, and interacts with transient receptor potential melastatin 8 (TRPM8) ion channels in cold-sensitive sensory neurons, and transient receptor potential ankyrin 1 (TRPA1), an irritant-sensing channel. It is highly controversial whether menthol in cigarette smoke exerts pharmacological actions affecting smoking behavior. Using plethysmography, we investigated the effects of menthol on the respiratory sensory irritation response in mice elicited by smoke irritants (acrolein, acetic acid, and cyclohexanone). Menthol, at a concentration (16 ppm) lower than in smoke of mentholated cigarettes, immediately abolished the irritation response to acrolein, an agonist of TRPA1, as did eucalyptol (460 ppm), another TRPM8 agonist. Menthol's effects were reversed by a TRPM8 antagonist, AMTB. Menthol's effects were not specific to acrolein, as menthol also attenuated irritation responses to acetic acid, and cyclohexanone, an agonist of the capsaicin receptor, TRPV1. Menthol was efficiently absorbed in the respiratory tract, reaching local concentrations sufficient for activation of sensory TRP channels. These experiments demonstrate that menthol and eucalyptol, through activation of TRPM8, act as potent counterirritants against a broad spectrum of smoke constituents. Through suppression of respiratory irritation, menthol may facilitate smoke inhalation and promote nicotine addiction and smoking-related morbidities.— Willis, D. N., Liu, B., Ha, M. A., Jordt, S.-E., Morris, J. B. Menthol attenuates respiratory irritation responses to multiple cigarette smoke irritants. PMID:21903934

  6. Cumulative irritation potential among metronidazole gel 1%, metronidazole gel 0.75%, and azelaic acid gel 15%.

    PubMed

    Colón, Luz E; Johnson, Lori A; Gottschalk, Ronald W

    2007-04-01

    Topical therapy for rosacea aims to reduce inflammatory lesions and decrease erythema but can carry side effects such as stinging, pruritus, and burning. Metronidazole and azelaic acid gel 15% are U.S. Food and Drug Administration-approved for the treatment of rosacea. The current study was conducted to assess the cumulative irritation potential of 2 formulations of metronidazole 0.75% gel and 1% gel--and azelaic acid gel 15% over 21 days (N=36). Results of this study demonstrated a significantly greater poten tial for irritation from azelaic acid compared with metronidazole gel 0.75% (P < .0001), which had significantly greater potential for irritation compared with metronidazole gel 1% (P = .0054). Metronidazole gel 1% had a similar profile to white petrolatum.

  7. Rationale for anti-inflammatory therapy in dry eye syndrome.

    PubMed

    de Paiva, C S; Pflugfelder, S C

    2008-01-01

    Dry eye is a multifactorial condition that results in a dysfunctional lacrimal functional unit. Evidence suggests that inflammation is involved in the pathogenesis of the disease. Changes in tear composition including increased cytokines, chemokines, metalloproteinases and the number of T cells in the conjunctiva are found in dry eye patients and in animal models. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. There are several anti-inflammatory therapies for dry eye that target one or more of the inflammatory mediators/pathways that have been identified and are discussed in detail.

  8. Toxicology of household cleaning products and disinfectants.

    PubMed

    Kore, A M; Kiesche-Nesselrodt, A

    1990-03-01

    Hundreds of different household cleaning products are available in homes, presenting potential hazards to pets. These products are complex mixtures of chemicals that vary widely in their toxic potential. Prevention of toxicoses in companion animals follows the same guidelines as those recommended for children: Keep cleaning products out of the reach of pets, do not leave open containers or solutions of cleaning products unattended where animals may get into them, make sure containers of cleaning products are tightly sealed and properly labeled, and dispose of any cleaning solutions promptly after use. If a companion animal has ingested or spilled a cleaning product or disinfectant on itself, it is very important to assess the potential hazard to the animal promptly. Many products contain warnings regarding the corrosive or irritation potential of the product and instructions on the label for preliminary action in the case of accidental oral, dermal, or ocular exposures in humans. These instructions can generally be followed initially until further information on the product can be obtained, although the recommendations on some product labels may be outdated. In general, the clinical management for toxicoses caused by cleaning products and disinfectants involves the prevention of further contact with the concentrated product through either dilution or bathing; emergency stabilization of the patient if clinical signs are present; instituting specific therapies, if available; and use of general supportive care.

  9. Some effects of chemical irritants on the membrane of the giant amoeba.

    PubMed Central

    Foster, R. W.; Weston, A. H.; Weston, K. M.

    1981-01-01

    1 The effects of chemical irritants on the membrane potential and input resistance of the giant amoeba, Chaos carolinense, have been investigated. The membrane potential and input resistance were -111.5 mV and 8.6 M pi respectively. 2 In the resting state the cell membrane of Chaos carolinense was found to be impermeable to Na+ but permeable to K+. The distribution of K+ across the cell membrane conformed to a Donnan equilibrium with the resting membrane potential being the K+ equilibrium potential. 3 The chemical irritants dibenzoxazepine and its 2-chloro- and 3-chloro-analogues and o-chlorobenzylidene malononitrile produced a fall in input resistance but no change in membrane potential. It is suggested that these effects are caused by an increase in K+ permeability. 4 The potencies of a series of chemical irritants with respect to dibenzoxazepine were measured on the giant amoeba. These potencies did not reflect those found in mammalian preparations. PMID:6797494

  10. Combined ocular and cervical vestibular evoked myogenic potential in individuals with vestibular hyporeflexia and in patients with Ménière's disease.

    PubMed

    Silva, Tatiana Rocha; de Resende, Luciana Macedo; Santos, Marco Aurélio Rocha

    The vestibular evoked myogenic potential is a potential of mean latency that measures the muscle response to auditory stimulation. This potential can be generated from the contraction of the sternocleidomastoid muscle and also from the contraction of extraocular muscles in response to high-intensity sounds. This study presents a combined or simultaneous technique of cervical and ocular vestibular evoked myogenic potential in individuals with changes in the vestibular system, for use in otoneurologic diagnosis. To characterize the records and analyze the results of combined cervical and ocular VEMP in individuals with vestibular hyporeflexia and in those with Ménière's disease. The study included 120 subjects: 30 subjects with vestibular hyporeflexia, 30 with Ménière's disease, and 60 individuals with normal hearing. Data collection was performed by simultaneously recording the cervical and ocular vestibular evoked myogenic potential. There were differences between the study groups (individuals with vestibular hyporeflexia and individuals with Ménière's disease) and the control group for most of wave parameters in combined cervical and ocular vestibular evoked myogenic potential. For cervical vestibular evoked myogenic potential, it was observed that the prolongation of latency of the P13 and N23 waves was the most frequent finding in the group with vestibular hyporeflexia and in the group with Ménière's disease. For ocular vestibular evoked myogenic potential, prolonged latency of N10 and P15 waves was the most frequent finding in the study groups. Combined cervical and ocular vestibular evoked myogenic potential presented relevant results for individuals with vestibular hyporeflexia and for those with Ménière's disease. There were differences between the study groups and the control group for most of the wave parameters in combined cervical and ocular vestibular evoked myogenic potential. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  11. Effects of environment pollution on the ocular surface.

    PubMed

    Jung, Se Ji; Mehta, Jodhbir S; Tong, Louis

    2018-04-01

    The twenty-first century is fraught with dangers like climate change and pollution, which impacts human health and mortality. As levels of pollution increase, respiratory illnesses and cardiovascular ailments become more prevalent. Less understood are the eye-related complaints, which are commonly associated with increasing pollution. Affected people may complain of irritation, redness, foreign body sensation, tearing, and blurring of vision. Sources of pollution are varied, ranging from gases (such as ozone and NO 2 ) and particulate matter produced from traffic, to some other hazards associated with indoor environments. Mechanisms causing ocular surface disease involve toxicity, oxidative stress, and inflammation. Homeostatic mechanisms of the ocular surface may adapt to certain chronic changes in the environment, so affected people may not always be symptomatic. However there are many challenges associated with assessing effects of air pollution on eyes, as pollution is large scale and difficult to control. Persons with chronic allergic or atopic tendencies may have a pre-existing state of heightened mucosal immune response, hence they may have less tolerance for further environmental antigenic stimulation. It is beneficial to identify vulnerable people whose quality of life will be significantly impaired by environmental changes and provide counter measures in the form of protection or treatment. Better technologies in monitoring of pollutants and assessment of the eye will facilitate progress in this field. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. A randomised crossover study comparing bimatoprost and latanoprost in subjects with primary angle closure glaucoma.

    PubMed

    How, A C S; Kumar, R S; Chen, Y-M; Su, D H; Gao, H; Oen, F T; Ho, C-L; Seah, S K; Aung, T

    2009-06-01

    To compare the intraocular pressure (IOP) lowering efficacy and side effects of latanoprost 0.005% and bimatoprost 0.03% in subjects with chronic primary angle closure glaucoma (PACG). This was an observer-masked randomised crossover study of 60 PACG subjects who received either latanoprost or bimatoprost for 6 weeks, after which they were crossed over to the other medication for another 6 weeks. The IOP-reducing effect of the medications was assessed by the reduction in IOP after 6 weeks of treatment compared with baseline. Fifty-four subjects (80 eyes) completed the study. Latanoprost reduced IOP (mean (SD)) by 8.4 (3.8) mm Hg and bimatoprost by 8.9 (3.9) mm Hg from a baseline of 25.2 (3.6) mm Hg and 25.2 (3.6) mm Hg respectively (p = 0.23). Adverse events were mild in both groups; however there were twice as many reports of an adverse event in the bimatoprost group (81%) compared with the latanoprost group (40%, p<0.01). Ocular irritation was the most frequently reported adverse event in both groups; 22 subjects (37.9%) treated with bimatoprost experienced ocular hyperaemia as compared with 13 subjects (22.4%) treated with latanoprost (p = 0.11). Bimatoprost once daily was similarly effective in reducing IOP compared with latanoprost once daily in subjects with chronic PACG. Both drugs were well tolerated with mild ocular adverse events.

  13. Design of nanosuspensions and freeze-dried PLGA nanoparticles as a novel approach for ophthalmic delivery of pranoprofen.

    PubMed

    Abrego, Guadalupe; Alvarado, Helen L; Egea, Maria A; Gonzalez-Mira, Elizabeth; Calpena, Ana C; Garcia, Maria L

    2014-10-01

    Pranoprofen (PF)-loaded poly (lactic-co-glycolic) acid (PLGA) nanoparticles (NPs) were optimized and characterized as a means of exploring novel formulations to improve the biopharmaceutical profile of this drug. These systems were prepared using the solvent displacement technique, with polyvinyl alcohol (PVA) as a stabilizer. A factorial design was applied to study the influence of several factors (the pH of the aqueous phase and the stabilizer, polymer and drug concentrations) on the physicochemical properties of the NPs. After optimization, the study was performed at two different aqueous phase pH values (4.50 and 5.50), two concentrations of PF (1.00 and 1.50 mg/mL), three of PVA (5, 10, and 25 mg/mL), and two of PLGA (9.00 and 9.50 mg/mL). These conditions produced NPs of a size appropriate particle size for ocular administration (around 350 nm) and high entrapment efficiency (80%). To improve their stability, the optimized NPs were lyophilized. X-ray, FTIR, and differential scanning calorimetry analysis confirmed the drug was dispersed inside the particles. The release profiles of PF from the primary nanosuspensions and rehydrated freeze-dried NPs were similar and exhibited a sustained drug delivery pattern. The ocular tolerance was assessed by an HET-CAM test. No signs of ocular irritancy were detected (score 0). © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  14. Cyclodextrin Enhances Corneal Tolerability and Reduces Ocular Toxicity Caused by Diclofenac

    PubMed Central

    Abdelkader, Hamdy; Fathalla, Zeinab; Moharram, Hossam; Ali, Taha F. S.

    2018-01-01

    With advances in refractive surgery and demand for cataract removal and lens replacement, the ocular use of nonsteroidal anti-inflammatory drugs (NSAIDs) has increased. One of the most commonly used NSAIDs is diclofenac (Diclo). In this study, cyclodextrins (CDs), α-, β-, γ-, and HP-β-CDs, were investigated with in vitro irritation and in vivo ulceration models in rabbits to reduce Diclo toxicity. Diclo-, α-, β-, γ-, and HP-β-CD inclusion complexes were prepared and characterized and Diclo-CD complexes were evaluated for corneal permeation, red blood cell (RBCs) haemolysis, corneal opacity/permeability, and toxicity. Guest- (Diclo-) host (CD) solid inclusion complexes were formed only with β-, γ-, and HP-β-CDs. Amphipathic properties for Diclo were recorded and this surfactant-like functionality might contribute to the unwanted effects of Diclo on the surface of the eye. Contact angle and spreading coefficients were used to assess Diclo-CDs in solution. Reduction of ocular toxicity 3-fold to16-fold and comparable corneal permeability to free Diclo were recorded only with Diclo-γ-CD and Diclo-HP-β-CD complexes. These two complexes showed faster healing rates without scar formation compared with exposure to the Diclo solution and to untreated groups. This study also highlighted that Diclo-γ-CD and Diclo-HP-β-CD demonstrated fast healing without scar formation. PMID:29636847

  15. A Comparison Study of Conjunctiva Disorders in Technical and Administrative Sawmill Workers in Nigeria

    PubMed Central

    Njinaka, Itiyafa; Uhumwangho, Odarosa M; Edema, Omolabake T; Dawodu, Oseluese A; Omoti, Afekhide E

    2011-01-01

    Background: Workers in the sawmilling industry are at risk of various ocular hazards as a direct result of the sawmilling processes. The aim of this study was to determine the pattern of conjunctival disorders between technical and administrative sawmill workers in Benin, Nigeria. Methods: A cross-sectional study was performed on sawmill workers in Benin, Nigeria, between January and May 2009, with the aid of pre-tested questionnaires. Ocular examination was performed on all subjects. Data obtained were recorded and analysed using SPSS version 13. Results: A total of 553 sawmill workers were studied, among whom 449 (81.2%) and 104 (18.8%) were technical and administrative workers, respectively. There were 496 (89.7%) males and 57 (10.3%) females. The age range was 15–80 years, with a mean of 38.9 years (SD 12.8). Pingueculum was found in 127 (23%) workers, among whom 122 (27.2%) were technical workers and 5 (4.8%) were administrative workers. Pterygium was present in 65 (11.8%) workers, among whom 64 (14.3%) were technical workers and 1 (1%) was an administrative worker. Seven (1.6%) technical workers used protective eyewear; 2 (0.4%) wore this protective eyewear regularly. Conclusion: Technical sawmill workers are at risk of developing conjunctival disorders, which result from chronic ocular irritation. This can be prevented by the provision of protective eye devices in the workplace. PMID:22135600

  16. A comparison study of conjunctiva disorders in technical and administrative sawmill workers in Nigeria.

    PubMed

    Njinaka, Itiyafa; Uhumwangho, Odarosa M; Edema, Omolabake T; Dawodu, Oseluese A; Omoti, Afekhide E

    2011-07-01

    Workers in the sawmilling industry are at risk of various ocular hazards as a direct result of the sawmilling processes. The aim of this study was to determine the pattern of conjunctival disorders between technical and administrative sawmill workers in Benin, Nigeria. A cross-sectional study was performed on sawmill workers in Benin, Nigeria, between January and May 2009, with the aid of pre-tested questionnaires. Ocular examination was performed on all subjects. Data obtained were recorded and analysed using SPSS version 13. A total of 553 sawmill workers were studied, among whom 449 (81.2%) and 104 (18.8%) were technical and administrative workers, respectively. There were 496 (89.7%) males and 57 (10.3%) females. The age range was 15-80 years, with a mean of 38.9 years (SD 12.8). Pingueculum was found in 127 (23%) workers, among whom 122 (27.2%) were technical workers and 5 (4.8%) were administrative workers. Pterygium was present in 65 (11.8%) workers, among whom 64 (14.3%) were technical workers and 1 (1%) was an administrative worker. Seven (1.6%) technical workers used protective eyewear; 2 (0.4%) wore this protective eyewear regularly. Technical sawmill workers are at risk of developing conjunctival disorders, which result from chronic ocular irritation. This can be prevented by the provision of protective eye devices in the workplace.

  17. Irritant and cytotoxic coumarins from Angelica glauca Edgew roots.

    PubMed

    Saeed, M Asif; Sabir, A W

    2008-01-01

    Irritant and cytotoxic potentiality of six coumarins, isolated for the first time from the roots of Angelica glauca identified as 5,6,7-trimethoxycoumarin, 6-methoxy-7,8-methylenedioxycoumarin, bergapten, decursinol angelate, decursin, and nodakenetin, were investigated. The irritant potential was explored by open mouse ear assay, evaluating their ID(50) after acute and by IU (Irritant units) after chronic effects, while the cytotoxic capability was explored by their LC(50), using brine shrimp (Artemia salina) larvae (nauplii). All the coumarins exhibited well-defined irritancy on mouse's ears, compared with the positive controlled euphorbium reaction and cytotoxic response against brine shrimp larvae, compared with the positive control colchicine. Decursinol angelate and decursin were the most potent and persistent irritant compounds with least ID(50), whose reactions lasted for 48 h. 6-Methoxy-7,8-methylenedioxycoumarin and bergaten revealed an intermediate irritant reactions, while 5,6,7-trimethoxycoumarin and nodakenetin displayed the least irritant and least persistent reactions on mouse ears. Both decursin and decursinol angelate also appeared to be the stronger cytotoxic agents than other coumarins. 5,6,7-trimethoxycoumarin displayed an intermediate cytotoxic behaviour, while other three coumarins, i.e., 6-methoxy-7,8-methylenedioxycoumarin, bergapten, and nodakenetin, exhibited the least cytotoxic capacity against brine shrimp larvae.

  18. Functional Brain Activation in Response to a Clinical Vestibular Test Correlates with Balance

    PubMed Central

    Noohi, Fatemeh; Kinnaird, Catherine; DeDios, Yiri; Kofman, Igor S.; Wood, Scott; Bloomberg, Jacob; Mulavara, Ajitkumar; Seidler, Rachael

    2017-01-01

    The current study characterizes brain fMRI activation in response to two modes of vestibular stimulation: Skull tap and auditory tone burst. The auditory tone burst has been used in previous studies to elicit either a vestibulo-spinal reflex [saccular-mediated colic Vestibular Evoked Myogenic Potentials (cVEMP)], or an ocular muscle response [utricle-mediated ocular VEMP (oVEMP)]. Research suggests that the skull tap elicits both saccular and utricle-mediated VEMPs, while being faster and less irritating for subjects than the high decibel tones required to elicit VEMPs. However, it is not clear whether the skull tap and auditory tone burst elicit the same pattern of brain activity. Previous imaging studies have documented activity in the anterior and posterior insula, superior temporal gyrus, inferior parietal lobule, inferior frontal gyrus, and the anterior cingulate cortex in response to different modes of vestibular stimulation. Here we hypothesized that pneumatically powered skull taps would elicit a similar pattern of brain activity as shown in previous studies. Our results provide the first evidence of using pneumatically powered skull taps to elicit vestibular activity inside the MRI scanner. A conjunction analysis revealed that skull taps elicit overlapping activation with auditory tone bursts in the canonical vestibular cortical regions. Further, our postural control assessments revealed that greater amplitude of brain activation in response to vestibular stimulation was associated with better balance control for both techniques. Additionally, we found that skull taps elicit more robust vestibular activity compared to auditory tone bursts, with less reported aversive effects, highlighting the utility of this approach for future clinical and basic science research. PMID:28344549

  19. [Comparison of 2 lacrimal punctal occlusion methods].

    PubMed

    Shalaby, O; Rivas, L; Rivas, A I; Oroza, M A; Murube, J

    2001-09-01

    To study and compare two methods for canalicular occlusion: Cautery and Punctal Patch. The study included fourty patients divided in two groups of 20 patients. The end point was 4 occluded puncti. The first group underwent deep cauterization resulting in occlusion of the full vertical aspect of the canaliculus. The second group underwent punctal patch technique for canalicular occlusion. Differential parameters were the following: time of intervention, ease of use, risks and precision. In the post operatory, discomfort, subjective and objective improvement in ocular surface as well as long term result of each technique was analysed. Time of intervention was longer for punctal patch compared to cautery. Both methods exhibited similar ease of use and improvement in ocular surface. Precision was high in punctal patch technique showing complete and final occlusion and no punctum needed reopening, while cautery technique presented 20% rate of reopening intervention. Postoperatory discomfort and irritation were remarkably evident with punctal technique, while minimal in cautery technique. Survival analysis after one year follow up, showed a higher rate of advantages for punctal patch technique over cautery technique.

  20. Aquaporins in the eye: Expression, function, and roles in ocular disease☆

    PubMed Central

    Schey, Kevin L.; Wang, Zhen; Wenke, Jamie L.; Qi, Ying

    2015-01-01

    Background All thirteen known mammalian aquaporins have been detected in the eye. Moreover, aquaporins have been identified as playing essential roles in ocular functions ranging from maintenance of lens and corneal transparency to production of aqueous humor to maintenance of cellular homeostasis and regulation of signal transduction in the retina. Scope of review This review summarizes the expression and known functions of ocular aquaporins and discusses their known and potential roles in ocular diseases. Major conclusions Aquaporins play essential roles in all ocular tissues. Remarkably, not all aquaporin function as a water permeable channel and the functions of many aquaporins in ocular tissues remain unknown. Given their vital roles in maintaining ocular function and their roles in disease, aquaporins represent potential targets for future therapeutic development. General significance Since aquaporins play key roles in ocular physiology, an understanding of these functions is important to improving ocular health and treating diseases of the eye. It is likely that future therapies for ocular diseases will rely on modulation of aquaporin expression and/or function. This article is part of a Special Issue entitled Aquaporins. PMID:24184915

  1. The evaluation of the local tolerance of vaginal formulations containing dapivirine using the Slug Mucosal Irritation test and the rabbit vaginal irritation test.

    PubMed

    Dhondt, Marijke M M; Adriaens, Els; Roey, Jens Van; Remon, Jean Paul

    2005-08-01

    The purpose of this study was to evaluate the local tolerance of vaginal gels (three gels containing dapivirine, the placebo gel, and Conceptrol) with the Slug Mucosal Irritation test and to compare the results with those of the rabbit vaginal irritation test. The irritation potential on the slug mucosa was assessed by the mucus production caused by a repeated treatment for 5 successive days. Additionally, membrane damage was estimated by the protein and enzyme release. By means of a classification prediction model the formulations were classified into four irritation classes. The effect of a 10-day intravaginal application of the gels on the rabbit vaginal and cervical mucosa was evaluated by means of macroscopic and microscopic examination. The placebo and dapivirine gels induced no irritation of the slug mucosa (low mucus production and protein release, no enzyme release) and no vaginal or cervical irritation in rabbits. Conceptrol caused severe irritation of the slug mucosa (increased mucus production, protein release, and enzyme release) and irritation of the rabbit vagina and cervix. The results obtained with the Slug Mucosal Irritation test were comparable to those of the rabbit vaginal irritation test.

  2. Irritant and sensitizing potential of eight surfactants commonly used in skin cleansers: an evaluation of 105 patients.

    PubMed

    Corazza, Monica; Lauriola, Maria Michela; Bianchi, Anna; Zappaterra, Mario; Virgili, Annarosa

    2010-01-01

    Irritation from surfactants contained in detergents is a frequent adverse reaction to cosmetics. Sensitization to surfactants is also possible. In the literature, comparative studies about irritant and sensitizing potential of different surfactants are heterogeneous and inconclusive about the best molecules to use. We compared the irritant and sensitizing potential of some surfactants that are usual components in marketed synthetic detergents (syndets) to obtain practical information regarding commonly used detergents. We patch-tested eight surfactants of the different types (anionic, cationic, amphoteric, and non-ionic) in 105 patients. Assessment of allergic reactions of tested surfactants was carried out in accordance with the recommendations of the International Contact Dermatitis Research Group; assessment of irritant power followed the amended Draize classification. None of the eight surfactants in our series gave positive allergic reactions. Only cocamidopropyl betaine from the Italian standard (Società Italiana di Dermatologia Allergologica, Professionale e Ambientale [SIDAPA]) series gave five positive reactions among 105 patients. None of the eight studied surfactants induced skin irritation. The most tolerated are two new mild anionics (sodium cocoyl glutamate and sodium lauroyl oat amino acids) and an amphoteric agent (disodium cocoamphodiacetate). From this study, we deduce that cosmetic companies' efforts to search for and market new products with very mild surfactants have been generally successful.

  3. Activity of a melimine derived peptide Mel4 against Stenotrophomonas, Delftia, Elizabethkingia, Burkholderia and biocompatibility as a contact lens coating.

    PubMed

    Dutta, Debarun; Zhao, Timothy; Cheah, Kai Bing; Holmlund, Larke; Willcox, Mark D P

    2017-06-01

    To determine the antimicrobial activity of the melimine derived peptide Mel4 against Delftia, Stenotrophomonas, Elizabethkingia, Burkholderia and to investigate biocompatibility of Mel4 as an antimicrobial coating on contact lenses in animals and humans. In vitro antimicrobial activity of Mel4 was determined against the four Gram negative bacteria by investigating growth curves for 24h followed by viable counts to determine the minimum inhibitory concentration (MIC). Contact lenses were coated by covalently binding Mel4, characterized by amino acid analysis, and were investigated for changes in lens parameters. Safety of Mel-4 coated lenses were determined in a rabbit model of daily contralateral wear. A prospective, randomised, double-masked, contralateral, 1week daily wear human clinical trial was used to evaluate subjective responses and ocular physiology. Mel4 was active against all the bacteria tested (MIC 50 ranged from 31-1000μgml -1 ) and produced an antimicrobial surface on contact lenses. Mel4-coating resulted hydrophilic surface without any significant change in contact lens parameters, and showed no signs of cytotoxicity or ocular irritation during rabbit wear. During human clinical trial, there were no differences between Mel4 coated and uncoated contact lenses in lens performance indicators and ocular signs such as corneal fluorescein staining. Mel4 and control uncoated lenses had no differences in ocular symptoms during lens wear. Mel4 has achieved antimicrobial activity against variety of Gram negative bacteria that are often resistant to the action of cationic peptides and have been implicated in contact lens related adverse events. Mel4-coated contact lenses were safe to wear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  4. Sensitization of trigeminal brainstem pathways in a model for tear deficient dry eye

    PubMed Central

    Rahman, Mostafeezur; Okamoto, Keiichiro; Thompson, Randall; Katagiri, Ayano; Bereiter, David A.

    2015-01-01

    Abstract Chronic dry eye disease (DE) is associated with an unstable tear film and symptoms of ocular discomfort. The characteristics of symptoms suggest a key role for central neural processing; however, little is known about central neuroplasticity and DE. We used a model for tear deficient DE and assessed effects on eye blink behavior, orbicularis oculi muscle activity (OOemg), and trigeminal brainstem neural activity in male rats. Ocular-responsive neurons were recorded at the interpolaris/caudalis transition (Vi/Vc) and Vc/upper cervical cord (Vc/C1) regions under isoflurane, whereas OOemg activity was recorded under urethane. Spontaneous tear volume was reduced by ∼50% at 14 days after exorbital gland removal. Hypertonic saline–evoked eye blink behavior in awake rats was enhanced throughout the 14 days after surgery. Saline-evoked neural activity at the Vi/Vc transition and in superficial and deep laminae at the Vc/C1 region was greatly enhanced in DE rats. Neurons from DE rats classified as wide dynamic range displayed enlarged convergent periorbital receptive fields consistent with central sensitization. Saline-evoked OOemg activity was markedly enhanced in DE rats compared with controls. Synaptic blockade at the Vi/Vc transition or the Vc/C1 region greatly reduced hypertonic saline–evoked OOemg activity in DE and sham rats. These results indicated that persistent tear deficiency caused sensitization of ocular-responsive neurons at multiple regions of the caudal trigeminal brainstem and enhanced OOemg activity. Central sensitization of ocular-related brainstem circuits is a significant factor in DE and likely contributes to the apparent weak correlation between peripheral signs of tear dysfunction and symptoms of irritation. PMID:25734990

  5. Use of 2-octyl cyanoacrylate for wound closure in a modified Roberts-Bistner procedure for eyelid agenesis in five cats (nine eyes).

    PubMed

    Reed, Zoe; Doering, Clinton J; Barrett, Paul M

    2018-01-15

    CASE DESCRIPTION 5 cats (9 eyes) were evaluated for surgical correction of bilateral eyelid agenesis. CLINICAL FINDINGS All eyes lacked > 25% of the temporal upper eyelid, and all cats had clinical signs attributable to chronic ocular exposure. Abnormalities were limited to the ocular surface in the 4 female cats, whereas the sole male cat had additional abnormalities consistent with anterior segment dysgenesis. TREATMENT AND OUTCOME A modified Roberts-Bistner procedure involving 2-octyl cyanoacrylate (2OCA) was performed on 9 eyes; 1 eye was enucleated. Surgical wounds in the initial 3 eyes were closed with 2OCA plus sutures, and flaps were lined with conjunctiva. The technique was optimized for remaining eyes by use of a single suture for flap apposition, no conjunctival lining of flaps, and 2OCA alone for wound closure. Median duration of surgery was 35 minutes/eye for the initial 3 eyes versus 16 minutes/eye for the subsequent 6 eyes treated with the optimized procedure. After surgery, all cats had complete palpebral reflexes and resolution of clinical signs of ocular irritation. Minor complications in the early postoperative period included eyelid swelling (n = 9), poor cosmesis (7), and persistent epiphora (3). By the second recheck examination, swelling had resolved and cosmesis was considered excellent. Two eyes with epiphora had been treated with the initial modified procedure and required cryoepilation for resolution of epiphora. CLINICAL RELEVANCE The modified Roberts-Bistner procedure for eyelid agenesis involving 2OCA for wound closure provided functional, cosmetic eyelids that improved comfort and provided protection of the ocular surface in affected cats.

  6. HSP27 as a biomarker for predicting skin irritation in human skin and reconstructed organotypic skin model.

    PubMed

    Chen, Hongxia; Li, Shuhua; Meng, Tian; Zhang, Lei; Dai, Taoli; Xiang, Qi; Su, Zhijian; Zhang, Qihao; Huang, Yadong

    2014-04-21

    In vitro alternative tests aiming at replacing the traditional animal test for predicting the irritant potential of chemicals have been developed, but the assessing parameters or endpoints are still not sufficient. To discover novel endpoints for skin irritation responses, 2DE-based proteomics was used to analyze the protein expression in human skin exposed to sodium lauryl sulfate (SLS) following the test protocol of the European Centre for the Validation of Alternative Methods (ECVAM) in the present study. HSP27 was up-regulated most significantly among the eight identified proteins, consistent with our previous reports. Acid and basic chemicals were applied on human skin for further validation and results showed that the up-regulated expression of HSP27 was induced in 24h after the exposure. Skin-equivalent constructed with fibroblasts, basement membrane and keratinocytes was used to investigate the potential of HSP27 as a biomarker or additional endpoint for the hazard assessment of skin irritation. Our skin-equivalent (Reconstructed Organotypic Skin Model, ROSM) had excellent epidermal differentiation and was suitable for the skin irritation test. HSP27 also displayed an up-regulated expression in the ROSM in 24h after the irritants exposure for 15min. All these results suggest that HSP27 may represent a potential marker or additional endpoint for the hazard assessment of skin irritation caused by chemical products. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Tandem repeated application of organic solvents and sodium lauryl sulphate enhances cumulative skin irritation.

    PubMed

    Schliemann, Sibylle; Schmidt, Christina; Elsner, Peter

    2014-01-01

    The objective of our study was to investigate the tandem irritation potential of two organic solvents with concurrent exposure to the hydrophilic detergent irritant sodium lauryl sulphate (SLS). A tandem repeated irritation test was performed with two undiluted organic solvents, cumene (C) and octane (O), with either alternating application with SLS 0.5% or twice daily application of each irritant alone in 27 volunteers on the skin of the back. The cumulative irritation induced over 4 days was quantified using visual scoring and non-invasive bioengineering measurements (skin colour reflectance, skin hydration and transepidermal water loss). Repeated application of C/SLS and O/SLS induced more decline of stratum corneum hydration and higher degrees of clinical irritation and erythema compared to each irritant alone. Our results demonstrate a further example of additive harmful skin effects induced by particular skin irritants and indicate that exposure to organic solvents together with detergents may increase the risk of acquiring occupational contact dermatitis. © 2014 S. Karger AG, Basel.

  8. Proposal of limit concentrations for skin irritation within the context of a new EEC directive on the classification and labeling of preparations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, G.; Martens, M.; Mosselmans, G.

    1987-12-01

    In this study, solvents belonging to different chemical families were tested for their irritating properties to the skin. The irritating potential of a chemical is expressed as its concentration in a nonirritant diluent beyond which irritation of the skin may be expected in the sense of EEC Directive 79/831/EEC. The substances were applied onto the shaved skin of rabbits by means of a modified Finn chamber for 4 hr. Afterward the exposure chamber was removed and the skin cleaned. Reading of erythema and edema was performed according to the scale of Draize at 1, 24, 48, and 72 hr aftermore » the removal of the patch. On the basis of the readings obtained the different dilutions of the organic solvents tested were classified as irritant or not according to the interpretation rules laid down in EEC Directive 83/467/EEC. On the basis of the structure-activity relationships found within each chemical family the irritation potential of the other members of the family could be derived via interpolation.« less

  9. A novel TRPM8 agonist relieves dry eye discomfort.

    PubMed

    Yang, Jee Myung; Li, Fengxian; Liu, Qin; Rüedi, Marco; Wei, Edward Tak; Lentsman, Michael; Lee, Hyo Seok; Choi, Won; Kim, Seong Jin; Yoon, Kyung Chul

    2017-06-26

    Physical cooling of the eye surface relieves ocular discomfort, but translating this event to drug treatment of dry eye discomfort not been studied. Here, we synthesized a water-soluble TRPM8 receptor agonist called cryosim-3 (C3, 1-diisopropylphosphorylnonane) which selectively activates TRPM8 (linked to cooling) but not TRPV1 or TRPA1 (linked to nociception) and tested C3 in subjects with mild forms of dry eye disease. A set of 1-dialkylphosphoryalkanes were tested for activation of TRPM8, TRPV1 and TRPA1 receptors in transfected cells. The bioactivity profiles were compared by perioral, topical, and intravenous delivery to anesthetized rats. The selected lead candidate C3 or vehicle (water) was applied with a cotton gauze pad to upper eyelids of patients with dry eye disease (n = 30). Cooling sensation, tear film break-up time (TBUT), basal tear secretion, and corneal staining were evaluated. C3 was then applied four times daily for 2 weeks to patients using a pre-loaded single unit applicator containing 2 mg/mL of C3 in water (n = 20) or water only. TBUT, basal tear secretion, and corneal staining, and three questionnaires surveys of ocular discomfort (VAS scale, OSDI, and CVS symptoms) were analyzed before and at 1 and 2 weeks thereafter. C3 was a selective and potent TRPM8 agonist without TRPV1 or TRPA1 activity. In test animals, the absence of shaking behavior after C3 perioral administration made it the first choice for further study. C3 increased tear secretion in an animal model of dry eye disease and did not irritate when wiped on eyes of volunteers. C3 singly applied (2 mg/ml) produced significant cooling in <5 min, an effecting lasting 46 min with an increase in tear secretion for 60 min. C3 applied for 2 weeks also significantly increased basal tear secretion with questionnaire surveys of ocular discomfort indices clearly showing improvement of symptoms at 1 and 2 weeks. No complaints of irritation or pain were reported by any subject. C3 is a promising candidate for study of TRPM8 function on the eye surface and for relief of dry eye discomfort. ISRCTN24802609 and ISRCTN13359367 . Registered 23 March 2015 and 2 September 2015.

  10. Classification of sensitizing and irritative potential in a combined in-vitro assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wanner, Reinhard, E-mail: reinhard.wanner@charite.d; Sonnenburg, Anna; Quatchadze, Maria

    2010-06-01

    We have developed a coculture system which in parallel indicates the sensitizing and irritative potential of xenobiotics. The assay is named loose-fit coculture-based sensitization assay (LCSA) and may be performed within 5 days. The system is composed of human monocytes that differentiate to a kind of dendritic cells by 2-day culturing in the presence of allogenic keratinocytes. The culture medium is enriched by a cocktail of recombinant cytokines. On day 3, concentration series of probes are added. On day 5, cells are harvested and analyzed for expression range of CD86 as a marker of sensitizing potential and for uptake ofmore » the viability stain 7-AAD as a marker of irritative potential. Estimation of the concentration required to cause a half-maximal increase in CD86 expression allowed quantification of sensitizing potential, and estimation of the concentration required to reduce viability to 50% allowed quantification of irritative potential. Examination of substances with known potential resulted in categorization of test scores. To evaluate our data, we have compared results with those of the validated animal-based sensitization test, the murine local lymph node assay (LLNA, OECD TG 429). To a large extent, results from LCSA and from LLNA achieved analogous grouping of allergens into categories like weak-moderate-strong. However, the new assay showed an improved capacity to distinguish sensitizers from non-sensitizers and irritants. In conclusion, the LCSA contains potential to fulfil the requirements of the EU's programme for the safety of chemicals 'Registration, Evaluation, Authorisation and Restriction of chemical substances' (REACH, 2006) to replace animal models.« less

  11. Ocular surface injury from a microwave superheated egg resulting in a pseudopterygium.

    PubMed

    Gagnon, Michael R; Dickinson, Paul J

    2005-05-01

    To describe the first case of ocular surface injury resulting in a pseudopterygium from a microwave superheated egg. Case report. A 12-year-old girl sustained an ocular surface injury resulting in a pseudopterygium from a microwave superheated egg. Microwave superheated eggs can result in ocular injury. This case illustrates the potential ocular danger involved with microwave ovens.

  12. Frequency-tuning characteristics of cervical and ocular vestibular evoked myogenic potentials induced by air-conducted tone bursts.

    PubMed

    Park, Hong Ju; Lee, In-Sik; Shin, Jung Eun; Lee, Yeo Jin; Park, Mun Su

    2010-01-01

    To better characterize both ocular and cervical vestibular evoked myogenic potentials (VEMP) responses at different frequencies of sound in 20 normal subjects. Cervical and ocular VEMPs were recorded. The intensities of sound stimulation decreased from the maximal intensity, until no responses were evoked. Thresholds, amplitudes, latencies and interaural amplitude difference ratio (IADR) at the maximal stimulation were calculated. Both tests showed the similar frequency tuning, with the lowest threshold and highest amplitude for 500-Hz tone-burst stimuli. Sound stimulation at 500Hz showed the response rates of 100% in both tests. Cervical VEMPs showed higher incidence than ocular VEMPs. Ocular VEMP thresholds were significantly higher than those of cervical VEMP. Cervical VEMP amplitudes were significantly higher than ocular VEMP amplitudes. IADRs of ocular and cervical VEMPs did not differ significantly. Ocular VEMP showed the similar frequency tuning to cervical VEMP. Cervical VEMP responses showed higher incidence, lower thresholds and larger amplitudes than ocular VEMP. Cervical VEMP is a more reliable measure than ocular VEMP, though the results of both tests will be complementary. Five hundred Hertz is the optimal frequency to use. Copyright 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Evaluation of 4-methylcyclohexanemethanol (MCHM) in a combined irritancy and Local Lymph Node Assay (LLNA) in mice.

    PubMed

    Johnson, Victor J; Auerbach, Scott S; Luster, Michael I; Waidyanatha, Suramya; Masten, Scott A; Wolfe, Mary S; Burleson, Florence G; Burleson, Gary R; Germolec, Dori R

    2017-07-01

    4-Methylcyclohexanemethanol (MCHM) is a flotation reagent used in fine coal beneficiation. On January 9, 2014, crude MCHM, a mixture containing predominantly MCHM, was inadvertently released into the Elk River, a municipal water source that serves about 300,000 people in the Charleston, WV area, resulting in temporary contamination of 15 percent of the state's tap water and causing significant dermal exposure. The current studies were undertaken to determine whether crude MCHM or MCHM has the potential to produce dermal irritancy and/or sensitization. BALB/c female mice were treated daily for 3 consecutive days by direct epicutaneous application of 25 μL of various concentrations of crude MCHM or MCHM to the dorsum of each ear. A mouse ear-swelling test was used to determine irritancy potential and was undertaken in combination with the standardized Local Lymph Node Assay (LLNA) to determine skin sensitizing potential. MCHM was found to produce skin irritation at concentrations above 20% and did not produce sensitization. Crude MCHM also produced irritation, although weaker, and in addition was found to be a weak to moderate skin sensitizer. The results are discussed in terms of potential human health hazard. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Validation study of the in vitro skin irritation test with the LabCyte EPI-MODEL24.

    PubMed

    Kojima, Hajime; Ando, Yoko; Idehara, Kenji; Katoh, Masakazu; Kosaka, Tadashi; Miyaoka, Etsuyoshi; Shinoda, Shinsuke; Suzuki, Tamie; Yamaguchi, Yoshihiro; Yoshimura, Isao; Yuasa, Atsuko; Watanabe, Yukihiko; Omori, Takashi

    2012-03-01

    A validation study on an in vitro skin irritation assay was performed with the reconstructed human epidermis (RhE) LabCyte EPI-MODEL24, developed by Japan Tissue Engineering Co. Ltd (Gamagori, Japan). The protocol that was followed in the current study was an optimised version of the EpiSkin protocol (LabCyte assay). According to the United Nations Globally Harmonised System (UN GHS) of classification for assessing the skin irritation potential of a chemical, 12 irritants and 13 non-irritants were validated by a minimum of six laboratories from the Japanese Society for Alternatives to Animal Experiments (JSAAE) skin irritation assay validation study management team (VMT). The 25 chemicals were listed in the European Centre for the Validation of Alternative Methods (ECVAM) performance standards. The reconstructed tissues were exposed to the chemicals for 15 minutes and incubated for 42 hours in fresh culture medium. Subsequently, the level of interleukin-1 alpha (IL-1 α) present in the conditioned medium was measured, and tissue viability was assessed by using the MTT assay. The results of the MTT assay obtained with the LabCyte EPI-MODEL24 (LabCyte MTT assay) demonstrated high within-laboratory and between-laboratory reproducibility, as well as high accuracy for use as a stand-alone assay to distinguish skin irritants from non-irritants. In addition, the IL-1α release measurements in the LabCyte assay were clearly unnecessary for the success of this model in the classification of chemicals for skin irritation potential. 2012 FRAME.

  15. Acrolein Causes TRPA1-Mediated Sensory Irritation and Indirect Potentiation of TRPV1-Mediated Pulmonary Chemoreflex Response

    EPA Science Inventory

    We previously demonstrated that acute exposure to acrolein causes immediate sensory irritation, with rapid decrease in heart rate (HR) and increase in inspiratory time (Ti), and potentiation of pulmonary chemoreflex response 24hrs later; of these effects only the latter is mediat...

  16. Biopharmaceutical Assessment and Irritation Potential of Microemulsions and Conventional Systems Containing Oil from Syagrus cearensis for Topical Delivery of Amphotericin B Using Alternative Methods.

    PubMed

    Sousa, Giovana D; Kishishita, Juliana; Aquino, Kátia A S; Presgrave, Octávio A F; Leal, Leila B; Santana, Davi P

    2017-07-01

    The aim of this study was to compare the biopharmaceutical characteristics and irritation potentials of microemulsions (MEs) and conventional systems (CSs) containing oil from Syagrus cearensis for topical delivery of Amphotericin B (AmB). Pseudo-ternary phase diagrams were constructed using a water titration method to develop the MEs, and the CSs were prepared according to the classical technique of phase inversion. In the skin permeation and retention study, dermatomed pig skin without stratum corneum was used as an alternative disturbed skin model. The irritation potential was evaluated using three different methods, chorioallantoic membrane assays (HET-CAM and CAM-TBS), and bovine corneal opacity and permeability (BCOP) test. The optimized formulation (ME1) consisting of 0.1% (w/w) Amphotericin B, 9.1% (w/w) catolé oil, 81% (w/w) Smix (1:1, Tween 20 and Kolliphor EL) possessed droplet size of 31.02 ± 0.9 nm, zeta potential of -23.4 mV, and viscosity 0.63 ± 0.1 Pa.s. ME1 exhibited greater retention of AmB in to skin layers (84.79 ± 2.08 μg cm -2 ) than all the others formulations. In general, MEs showed higher drug release and retention than CSs and all of the formulations showed greater retentivity than permeability. Only MEs developed using Labrasol/Plurol Oleique (L/PO) as the surfactant and co-surfactant exhibited a moderate irritation potential; all other MEs and CSs were classified as non-irritants or slight irritants. The results indicate that formulations containing oil from S. cearensis are promising alternatives for the delivery of AmB targeting the treatment of cutaneous leishmaniasis.

  17. The bioreactivity of the sub-10 μm component of volcanic ash: Soufrière Hills volcano, Montserrat.

    PubMed

    Jones, Timothy; Bérubé, Kelly

    2011-10-30

    With the recent eruption of the Icelandic volcano Eyafallajökull and resulting ash cloud over much of Europe there was considerable concern about possible respiratory hazards. Volcanic ash can contain minerals that are known human respiratory health hazards such as cristobalite. Short-term ash exposures can cause skin sores, respiratory and ocular irritations and exacerbation of pre-existing lung conditions such as asthma. Long-term occupational level exposures to crystalline silicon dioxide can cause lung inflammation, oedema, fibrosis and cancer. The potential health effects would be dependent on factors including mineralogy, surface chemistry, size, and levels and duration of exposure. Bulk ash from the Soufrière Hills volcano was sourced and inhalable (<2.5 μm) ash samples prepared and physicochemically characterised. The fine ash samples were tested for bioreactivity by SDS-PAGE which determined the strength of binding between mineral grains and lung proteins. Selected proteins bound tightly to cristobalite, and bound loosely to other ash components. A positive correlation was seen between the amount of SiO(2) in the sample and the strength of the binding. The strength of binding is a function of the mineral's bioreactivity, and therefore, a potential geo-biomarker of respiratory risk. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Acute and long-term ocular effects of acrolein vapor on the eyes and potential therapies.

    PubMed

    Dachir, Shlomit; Cohen, Maayan; Gutman, Hila; Cohen, Liat; Buch, Hillel; Kadar, Tamar

    2015-01-01

    Acrolein is a potent irritant and a vesicant that was used by the French during WWI as the warfare agent named: "papite". Nowadays, it is produced in large amounts all over the world in the industry for the production of acrylic acid and for agriculture use as herbicide. The aim of this study was to characterize the effects of acute eye exposure to acrolein vapor and to evaluate the efficacy of a topical post-exposure combination treatment with a local anesthetic and a steroid. Rabbit eyes were exposed to three doses of acrolein vapor (low, intermediate and high) and treated topically with either 0.4% benoxinate hydrochloride (localin, for 2 h) or dexamethasone (dexamycin, for 6 days) or a combination of both drugs. Clinical follow-up using slit lamp examinations and histological evaluation was performed 4 weeks post-exposure. Acrolein vapor caused immediate eye closure with excess tearing, corneal erosions and severe inflammation of the anterior chamber. This was followed by corneal neovascularization (NV) starting as early as 1 week post-exposure. The damage to the eyes was long lasting, and at 4 weeks following exposure, significant pathological changes were observed. Immediate post-exposure application of the local anesthetic, localin, prevented the eye closure, and the dexamycin treatment reduced significantly the initial inflammation as well as the extent and incidence of corneal NV. Short-term eye exposure to the irritant acrolein may result in immediate eye closure and long lasting pathologies that could lead to blindness. An anti-inflammatory treatment combined with short-term application of a local anesthetic prevents incapacitation and might minimize significantly the extent of eye injuries.

  19. Predictive performance and inter-laboratory reproducibility in assessing eye irritation potential of water- and oil-soluble mixtures using the Short Time Exposure test method.

    PubMed

    Abo, Takayuki; Hilberer, Allison; Behle-Wagner, Christine; Watanabe, Mika; Cameron, David; Kirst, Annette; Nukada, Yuko; Yuki, Takuo; Araki, Daisuke; Sakaguchi, Hitoshi; Itagaki, Hiroshi

    2018-04-01

    The Short Time Exposure (STE) test method is an alternative method for assessing eye irritation potential using Statens Seruminstitut Rabbit Cornea cells and has been adopted as test guideline 491 by the Organisation for Economic Co-operation and Development. Its good predictive performance in identifying the Globally Harmonized System (GHS) No Category (NC) or Irritant Category has been demonstrated in evaluations of water-soluble substances, oil-soluble substances, and water-soluble mixtures. However, the predictive performance for oil-soluble mixtures was not evaluated. Twenty-four oil-soluble mixtures were evaluated using the STE test method. The GHS NC or Irritant Category of 22 oil-soluble mixtures were consistent with that of a Reconstructed human Cornea-like Epithelium (RhCE) test method. Inter-laboratory reproducibility was then confirmed using 20 water- and oil-soluble mixtures blind-coded. The concordance in GHS NC or Irritant Category among four laboratories was 90%-100%. In conclusion, the concordance in comparison with the results of RhCE test method using 24 oil-soluble mixtures and inter-laboratory reproducibility using 20 water- and oil-soluble mixtures blind-coded were good, indicating that the STE test method is a suitable alternative for predicting the eye irritation potential of both substances and mixtures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. The isolated chicken eye test as a suitable in vitro method for determining the eye irritation potential of household cleaning products.

    PubMed

    Schutte, K; Prinsen, M K; McNamee, P M; Roggeband, R

    2009-08-01

    Eye irritation is an important endpoint in the safety evaluation of consumer products and their ingredients. Several in vitro methods have been developed and are used by different industry sectors to assess eye irritation. One such in vitro method in use for some time already is the isolated chicken eye test (ICE). This investigation focuses on assessing the ICE as a method to determine the eye irritation potential of household cleaning products, both for product safety assurance prior to marketing and for classification and labeling decisions. The ICE involves a single application of test substances onto the cornea of isolated chicken eyes. Endpoints are corneal swelling, corneal opacity and fluorescein retention. The ICE results were compared to historic LVET data in this study due to availability of such in vivo data and the ability to correlate LVET to human experience data on the outcome of accidental exposures to household cleaning products in general. The results of this study indicate that the ICE test is a useful in vitro method for evaluating the eye irritation/corrosion potential and establishing classification and labeling for household cleaning products. For new product formulations, it is best used as part of a weight-of-evidence approach and benchmarked against data from comparable formulations with known eye irritation/corrosion profiles and market experience.

  1. Managing Sjögren's Syndrome and non-Sjögren Syndrome dry eye with anti-inflammatory therapy.

    PubMed

    Coursey, Terry G; de Paiva, Cintia S

    2014-01-01

    Dry eye from Sjögren's syndrome is a multifactorial disease that results in dysfunction of the lacrimal functional unit. Studies have shown changes in tear composition, including inflammatory cytokines, chemokines, and metalloproteinase. T-lymphocytes have been shown to increase in the conjunctiva and lacrimal glands in patient and animal models. This inflammation is in part responsible for the pathogenesis of the disease, which results in symptoms of eye irritation, ocular surface epithelial disease, and loss of corneal barrier function. There are a number of anti-inflammatory approaches for treating this disease. The current study reviews details of immune response and anti-inflammatory therapies used to control this disease.

  2. Toxicological and pharmacological effects of gadolinium and samarium chlorides

    PubMed Central

    Haley, T. J.; Raymond, K.; Komesu, N.; Upham, H. C.

    1961-01-01

    A study has been made of the toxicology and pharmacology of gadolinium and samarium chlorides. The symptoms of acute toxicity following intraperitoneal injection are described. The chronic oral ingestion of both chemicals for 12 weeks produced no effects on growth or the blood picture, and only the male rats receiving gadolinium chloride showed liver damage. The pharmacological responses to both chemicals were mainly depressant on all systems studied, and death was associated with cardiovascular collapse coupled with respiratory paralysis. The greatest damage seen was on abraded skin, where non-healing ulcers were produced by both chemicals, whereas irritation of intact skin and ocular tissues was only transient in nature. PMID:13903826

  3. Effect of sperminated pullulans on drug permeation through isolated rabbit cornea and determination of ocular irritation.

    PubMed

    Yu, N; Xun, Y; Jin, D; Yang, H; Hang, T; Cui, H

    2010-01-01

    The aim of this study was to investigate the effect of two sperminated pullulans (SP) with a different number of amino groups (SP-L, amino group content 0.124 mmol/g polymer; and SP-H, amino group content 0.578 mmol/g polymer) on the permeation of drugs through isolated rabbit corneas. Determination of corneal hydration levels and Draize eye tests were performed to assess the safety of SP both in vitro and in vivo. For 0.2% (w/v) SP-L and 0.2% (w/v) SP-H, the enhancement ratios (ERs) with dexamethasone of 1.34 and 1.42, respectively, were not statistically significant. For ofloxacin, tobramycin and sodium fluorescein, the ERs with 0.2% SP-L were 1.37, 2.02 and 2.12, respectively, and with 0.2% SP-H the ERs were 1.84, 4.69 and 6.87, respectively; these ERs were all statistically significant. Enhancement increased with increasing amino group content of the SP. The improved transcorneal drug absorption via the paracellular route indicated opening of the tight junctions in the corneal epithelium. Irritation tests indicated that 0.2% SP-L and 0.2% SP-H did not damage the corneal tissues.

  4. Comparison of the cumulative irritation potential of adapalene gel and cream with that of erythromycin/tretinoin solution and gel and erythromycin/isotretinoin gel.

    PubMed

    Queille-Roussel, C; Poncet, M; Mesaros, S; Clucas, A; Baker, M; Soloff, A M

    2001-02-01

    Adapalene is a naphthoic acid derivative with retinoid activity that is effective in the treatment of mild to moderate acne vulgaris. This study assessed the cumulative irritation potential of adapalene gel (0.1%) and adapalene cream (0.1%) compared with that of erythromycin (4%)/tretinoin (0.025%) solution, erythromycin (4%)/tretinoin (0.025%) gel, erythromycin (2%)/isotretinoin (0.05%) gel, and white petrolatum (negative control). This was a single-center, randomized, controlled, investigator-blinded, intraindividual comparison study in healthy subjects with normal skin. The cumulative irritation assay (patch test) was used to assess the potential for irritation (including erythema) of the treatments. Each subject received all study treatments, randomly applied under occlusion (patch), to sites on either side of the midline on the mid-thoracic area of the back. All patches were applied to the same sites throughout the study, unless the degree of reaction to the treatment or adhesive necessitated removal. For 3 weeks, each test material was applied daily, Monday through Friday, for approximately 24 hours; the Friday patches were left in place over the weekend for approximately 72 hours. All 36 subjects (26 men, 10 women; age, 18-49 years [mean, 30 years]) completed the study. In the course of the study, all subjects had > or =1 application discontinued prematurely on > or =1 site due to intolerance. There were no discontinuations with white petrolatum. All erythromycin/tretinoin gel patches were discontinued at day 10; 35 of 36 erythromycin/isotretinoin gel patches were discontinued at day 9; and 35 of 36 erythromycin/tretinoin solution patches were discontinued at day 11 or day 17. The adapalene products, although slightly more irritating (mean cumulative irritation index, 0.25-1) than white petrolatum, were significantly less irritating than the erythromycin/tretinoin and erythromycin/isotretinoin products (P < 0.01). Adapalene gel and cream were well tolerated, with possible benefits for compliance. Their low irritation potential should be considered when prescribing a topical retinoid for the treatment of acne vulgaris.

  5. Irritability in Pediatric Patients: Normal or Not?

    PubMed Central

    Hameed, Usman; Dellasega, Cheryl A.

    2016-01-01

    The goal of this article is to describe the concept of irritability in children and youth, which has been revisited in the DSM-5. Traditionally, this behavior has been more commonly associated with mood disorders, which may account for the rising incidence of bipolar disorder diagnosis and overuse of mood-stabilizing medications in pediatric patients. While not predictive of mania, persistent nonepisodic irritability, if undetected, may escalate to violent behavior with potentially serious outcomes. It is therefore important to educate clinicians about how to accurately assess irritability in pediatric patients. PMID:27486529

  6. A comprehensive evaluation of the carcinogenic potential of middle distillate fuels.

    PubMed

    Nessel, C S

    1999-02-01

    Middle distillate fuels (MDFs), which include jet fuel, kerosene, and diesel fuel, are a class of hydrocarbons distilled from crude oil at approximately 350-700 degrees F (176-371 degrees C). Although MDFs generally do not contain appreciable levels of potentially carcinogenic polycyclic aromatic compounds (PACs), they have produced weak tumorigenic responses in mouse skin characterized by low tumor yield and long latency. Recent studies demonstrated that the tumorigenic effects of these MDFs were dependent upon chronic dermal irritation. In the absence of skin irritation, tumors did not develop. Mechanistic studies suggest that straight-run MDFs containing low levels of PACs cause skin tumors through a nongenotoxic mechanism. MDFs cause chronic skin irritation and injury with repeated application to the skin. They have been found to have little or no activity in the modified Ames mutagenicity assay, lack tumor initiating activity, and are active skin tumor promoters. It has been hypothesized that the tumorigenic response to MDFs results from the promotion of preexisting, spontaneously initiated cells. Two recent studies, a one-year tumor promotion study and a two-year skin painting study, evaluated the role of skin irritation on the tumorigenic activity of MDFs in mice. MDFs were applied in pure and diluted forms to assess the effect of equal weekly doses of irritating and nonirritating test materials. The tumorigenicity of straight-run MDFs correlated to the level of skin irritation. No significant increase in tumor incidence occurred under conditions that resulted in minimal skin irritation and injury. These studies indicate that the tumorigenic activity of MDFs containing low levels of PACs is secondary to chronic skin irritation. These materials should not present a carcinogenic hazard in the absence of prolonged skin irritation.

  7. Dermatitis and aircrew.

    PubMed

    Leggat, Peter A; Smith, Derek R

    2006-01-01

    Dermatitis is a common problem both in the workplace and in the general community. Airline personnel represent a novel occupational group as they are also exposed to a wide range of potential chemical irritants and other aggravating factors, such as low relative humidity and airborne pollutants. Common skin irritants include dielectric fluids from electrodischarge machining, 'prepreg' materials and sealants in aircraft manufacture, kerosene and various jet-fuel components. Commercial jet fuel is a complex mixture of aliphatic and aromatic compounds, and there is potential for dermal exposure among refueling and maintenance crew. Low relative humidity appears to exacerbate dermatitis amongst aircrew, especially on longer flight durations. Pilots may also be exposed to additional skin irritants outside of the cabin environment, such as ethylene glycol, hydraulic fluid or jet fuel, all of which may be encountered during routine inspections of aircraft before and after flight. Given these factors, preventive measures must carefully consider the undoubted potential for contact with irritants and allergens, which may lead to dermatitis in airline personnel.

  8. Skin and Eye Irritation Assessment of Oil Palm ( Elaeis guineensis) Leaf Extract for Topical Application.

    PubMed

    Yusof, Nor Zuliana; Abd Gani, Siti Salwa; Azizul Hasan, Zafarizal Aldrin; Idris, Zainab

    2018-01-01

    Many types of phytochemicals have been found to be present in oil palm leaf and could potentially be used as functional ingredients for skincare product. However, as of today, there is no published report on hazard identification and safety assessment of oil palm ( Elaeis guineensis) leaf extract (OPLE), particularly on skin and eye irritation. In this study, potential hazard of OPLE on skin and eye irritation was evaluated as an initial step to the safety assessment of OPLE. In vitro cell viability study of OPLE on normal human dermal fibroblasts showed that OPLE was nontoxic to the cells with percentage viability more than 90% after 24 and 48 hours of incubation. Skin irritation potential of OPLE was evaluated using in vitro SkinEthic reconstructed human epidermis (RHE) model (Organization for Economic Cooperation and Development [OECD] Test Guideline 439, 2015), while eye irritation potential was evaluated using in vitro SkinEthic Human corneal epithelium (HCE) model (OECD test guideline 492, 2017). Hazard identification results showed that OPLE at 1%, 5%, and 10% (wt/wt) was classified as nonirritant to the skin and eye where mean tissue viabilities of SkinEthic RHE and SkinEthic HCE were more than 50% and 60%, respectively. Therefore, we recommend a further safety assessment, such as human patch testing, to confirm the nonirritant of OPLE.

  9. Comparative studies of various hyaluronic acids produced by microbial fermentation for potential topical ophthalmic applications.

    PubMed

    Guillaumie, Fanny; Furrer, Pascal; Felt-Baeyens, Olivia; Fuhlendorff, Birgit L; Nymand, Søren; Westh, Peter; Gurny, Robert; Schwach-Abdellaoui, Khadija

    2010-03-15

    This work presents a comparative study of various hyaluronic acids (HA) produced by fermentation of either Bacillus subtilis or Streptococcus towards the selection of an optimal molecular weight (MW) HA for the preparation of topical ophthalmic formulations. The influence of HA MW on water binding capacity, sterile filtration, rheological properties, precorneal residence time and ocular tolerance of ophthalmic solutions was investigated. Molecular weight did not affect hydration of hyaluronic acid according to differential scanning calorimetry (DSC). In general, medium MW HA (0.6-1 MDa) resulted in solutions that were superior in terms of sterile filtration and kinematic viscosity requirements compared to high MW HA (>1 MDa). Moreover, all HA-based solutions exhibited well-defined viscoelastic properties that depend on MW. Gamma scintigraphic data indicated that HA MW at 0.1% concentration (w/v) and HA origin did not significantly affect the corneal residence time on rabbit eyes. A 0.3% solution of high MW HA had a prolonged residence time in the precorneal area compared to a medium MW HA at the same concentration. Finally, an in vivo ocular irritation test based on confocal laser scanning ophthalmoscopy (CLSO) conclusively showed the excellent tolerance of both Bacillus-derived HA and Streptococcus-derived HA after topical instillation onto the corneal surface. Overall, this comprehensive work highlights the superiority of medium MW hyaluronic acid for topical ophthalmic formulations based on their physico-chemical and biological properties, tolerance and handling. Such solutions are expected to enhance tear film stability, to allow for maximum comfort, and to exhibit high residence times, while being biocompatible and easy to sterile filter. (c) 2009 Wiley Periodicals, Inc.

  10. Evaluation of modifications of the traditional patch test in assessing the chemical irritation potential of feminine hygiene products.

    PubMed

    Farage, Miranda A; Meyer, Sandy; Walter, Dave

    2004-05-01

    The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test product or a particular protocol variation. However, the mean irritation scores at those sites where a sensory effect was reported were higher than the mean irritation scores at those sites were no sensory effects were reported. All four protocol variations of the standard upper arm patch test can be used to assess the inherent chemical irritant properties of feminine protection products. For these products, which are inherently non-irritating, tape stripping and/or applying wet samples does not increase the sensitivity of the patch test method. Differences in irritation potential were apparent after one to three 24-h applications. Therefore, the standard patch test protocol can be shortened to three applications without compromising our ability to detect differences in the chemical irritation produced by the test materials. The patch test can be used to evaluate effectively the inherent chemical irritation potential of these types of products. However, this method is not suitable for testing the mechanical irritation due to friction that occurs during product use. There is no relationship between specific test conditions, i.e., compromised skin and/or testing wet samples and reports of perceived sensory reactions. However, there seems to be a clear relationship between sensory reactions and objective irritation scores.

  11. Clinical effect of four different ointment bases on healthy cat eyes.

    PubMed

    Eördögh, Réka; Schwendenwein, Ilse; Tichy, Alexander; Loncaric, Igor; Nell, Barbara

    2016-07-01

    To describe the effects of long-term treatment with four different eye ointment bases (OBs) in cats. Ten healthy cats. The study was performed in two periods. Four different OBs were tested. Hundred grams of OB contained the following: OB-A: 35.17 g liquid paraffin (lp), 64.83 g white petrolatum (wp); OB-B: 10.03 g lp, 84.95 g wp 5.02 g lanolin; OB-C: 18.34 g lp, 51.40 g wp, 25.00 mg KH2 PO4 , 57.00 mg K2 HPO4 , 18.90 g eucerinum anhydricum, 11.28 g water for injections; and OB-D: 70 g unguentum lanalcoli, 20 g lp, 10 g aqua conservans. One eye was treated, and the other served as a negative control. Cats received the OBs TID for 28 days. The two study periods were separated by a 4-month washout phase. Samples for conjunctival impression cytology, swabs for bacteriologic and mycologic examination, and cytobrush samples for FHV-1 and Chlamydophila felis PCR detection were obtained. Both eyes were examined daily. Severity of ocular symptoms was scored using a modified Draize eye irritation test. A total of five eyes were treated with OB-A, five with OB-B, four with OB-C, and five with OB-D. Treated eyes had significantly higher clinical scores. Eyes receiving OB-A had the highest overall clinical score. The results of bacteriologic and mycologic examination concur with the previously published data. All samples tested were negative for FHV-1 and Chlamydophila felis. There was no significant difference between treated and control eyes upon cytological examination. The application of OBs resulted in clinical symptoms in treated eyes. The long-term use of ointments is not well tolerated in cats and may lead to ocular irritation. © 2015 American College of Veterinary Ophthalmologists.

  12. Osmolarity of prevalent eye drops, side effects, and therapeutic approaches.

    PubMed

    Dutescu, Ralf M; Panfil, Claudia; Schrage, Norbert

    2015-05-01

    Little is known about how the osmolarity of ophthalmic formulations affects the ocular surface. Because hyperosmolar eye drops could be therapeutic for treating corneal edema, this article presents an ex vivo model of corneal edema for testing ophthalmic drugs based on their osmolarity. The respective osmolarity of common eye drops found in the German market is also analyzed here. For modeling corneal edema, an Ex Vivo Eye Irritation Test was used to simulate an ocular anterior chamber with a physiological corneal barrier. To induce corneal edema, the anterior chamber was supplied with a hypoosmolar medium (148 mOsm/L) for 24 hours. Preserved and preservative-free 5% sodium chloride (hyperosmolar Omnisorb and Ocusalin 5% UD) were used for 1 hour, on 5 corneas each, to test their efficiency to reduce corneal edema in this model. Corneal thickness was determined by optical coherence tomography. Osmolarity of 87 common eye drops was measured by freezing point osmometry. Ex vivo, the tested hypoosmolar condition induced corneal edema from 450 μm (±50 μm) at baseline to 851 μm (±94 μm, P < 0.0001). Omnisorb and Ocusalin 5% UD significantly reduced the corneal thickness by 279 μm (±28 μm, P < 0.001) for Omnisorb and 258 μm (±29 μm, P < 0.001) for Ocusalin 5% UD. Forty-three (49%) of the tested products had an osmolarity below and 44 (51%) above the physiological tear osmolarity of 289 mOsm/L. Osmolarity values of less than 200 mOsm/L were found in lubricant drops. The highest osmolarity was detected in Omnisorb (1955 mOsm/L). The Ex Vivo Eye Irritation Test has proven to be a reliable novel model of corneal edema for evaluating osmotic eye drops. Osmolarity measurements revealed a wide range from hypotonic to hypertonic formulations for commonly marketed ophthalmic drugs.

  13. Cutaneous irritancy of an ibuprofen medicated plaster in healthy volunteers.

    PubMed

    Maganji, Manisha; Connolly, Mark P; Bhatt, Aomesh

    2018-04-01

    To assess the irritation and contact sensitization potential of a 200 mg ibuprofen medicated plaster. This double-blind, phase-1 placebo controlled study had two phases; the induction phase to evaluate the irritant potential of continuous application of the plaster, and the challenge phase to assess contact sensitivity (allergy). The cumulative irritancy potential was evaluated using an adaptation of the Shelanski method. Healthy adults (≥18 years of age) (N = 210) were treated simultaneously with one ibuprofen medicated and one placebo plaster applied in a randomized fashion to either the left or right side of the lower back. During the induction phase, plasters were applied on Days 1, 3, 5, 8, 10, 12, 15, 17, and 19 and the final plaster removed on Day 22. At each scheduled visit plasters and applications sites were assessed for degree of adhesion and skin irritation (score of 1 = no irritation to 7 = strong reaction spreading beyond test sites), respectively. The challenge phase followed a two-week washout period. A plaster was applied on Day 36 for 48 h and assessment occurred on Days 38, 39, and 40. The mean cumulative irritation score during the induction phase was lower for the ibuprofen medicated plaster than the placebo plaster (0.32 vs. 1.23, respectively). Three (1.4%) subjects experience a dermal reaction of grade ≥3 for the ibuprofen medicated plaster compared with 27 (12.7%) for the placebo plaster. Following challenge with ibuprofen or placebo plasters, 12 subjects (6.2%) with the ibuprofen medicated plaster and four (2.2%) with the placebo plaster had skin reaction of assessment grade higher than the induction phase. One subject for the ibuprofen and two for the placebo plaster had reactions with grade >2. No subjects showed an increase in sensitization on Day 39 or 40 compared with Day 38. The findings indicate that the both the irritancy and contact sensitization of the ibuprofen medicated plaster is acceptable.

  14. Final report of the addendum to the safety assessment of n-butyl alcohol as used in cosmetics.

    PubMed

    McLain, Valerie C

    2008-01-01

    n-Butyl Alcohol is a primary aliphatic alcohol historically used as a solvent in nail care cosmetic products, but new concentration of use data indicate that it also is being used at low concentrations in eye makeup, personal hygiene, and shaving cosmetic products. n-Butyl Alcohol has been generally recognized as safe for use as a flavoring substance in food and appears on the 1982 Food and Drug Administration (FDA) list of inactive ingredients for approved prescription drug products. n-Butyl Alcohol can be absorbed through the skin, lungs, and gastrointestinal tract. n-Butyl Alcohol may be formed by hydrolysis of butyl acetate in the blood, but is rapidly oxidized. The single oral dose LD(50) of n-Butyl Alcohol for rats was 0.79 to 4.36 g/kg. The dermal LD(50) for rabbits was 4.2 g/kg. Inhalation toxicity studies in humans demonstrate sensory irritation of the upper respiratory tract, but only at levels above 3000 mg/m(3). Animal studies demonstrate intoxication, restlessness, ataxia, prostration, and narcosis. Exposures of rats to levels up to 4000 ppm failed to produce hearing defects. High concentrations of n-Butyl Alcohol vapors can be fatal. Ocular irritation was observed for n-Butyl alcohol at 0.005 ml of a 40% solution. The behavioral no-effect dose for n-Butyl Alcohol injected subcutaneously (s.c.) was 120 mg/kg. Fetotoxicity has been demonstrated, but only at maternally toxic levels (1000 mg/kg). No significant behavioral or neurochemical effects were seen in offspring following either maternal or paternal exposure to 3000 or 6000 ppm. n-Butyl Alcohol was not mutagenic in Ames tests, did not induce sister-chromatid exchange or chromosome breakage in chick embryos or Chinese hamster ovary cells, did not induce micronuclei formation in V79 Chinese hamster cells, did not have any chromosome-damaging effects in a mouse micronucleus test, and did not impair chromosome distribution in the course of mitosis. Clinical testing of n-Butyl Alcohol for nonimmunological contact urticaria was negative in 105 subjects. Repeat-insult patch test (RIPT) studies of nail colors and enamels containing 3% n-Butyl Alcohol in one study produced reactions on challenge, but further study linked significant positive reactions to another solvent. In other RIPT studies, only minimal reactions were reported. A photopatch test demonstrated that a nail enamel containing 3% n-Butyl Alcohol resulted in no reactions. Workers complained of ocular irritation, disagreeable odor, slight headache and vertigo, slight irritation of nose and throat, and dermatitis of the fingers and hands when the air concentration of n-Butyl Alcohol was greater than 50 ppm, as compared to an odor threshold in air of 0.83 ppm. The available safety test data were considered adequate to support the safety of n-Butyl Alcohol in all cosmetic product categories in which it is currently used.

  15. Implementation Intentions as a Strategy to Increase the Notification Rate of Potential Ocular Tissue Donors by Nurses: A Clustered Randomized Trial in Hospital Settings

    PubMed Central

    2014-01-01

    Aim. The purpose of this study is to evaluate the impact, among nurses in hospital settings, of a questionnaire-based implementation intentions intervention on notification of potential ocular tissue donors to donation stakeholders. Methods. This randomized intervention was clustered at the level of hospital departments with two study arms: questionnaire-based implementation intentions intervention and control. In the intervention group, nurses were asked to plan specific actions if faced with a number of barriers when reporting potential ocular donors. The primary outcome was the potential ocular tissue donors' notification rate before and after the intervention. Analysis was based on a generalized linear model with an identity link and a binomial distribution. Results. We compared outcomes in 26 departments from 5 hospitals, 13 departments per condition. The implementation intentions intervention did not significantly increase the notification rate of ocular tissue donors (intervention: 23.1% versus control: 21.1%; χ 2 = 1.14, 2; P = 0.56). Conclusion. A single and brief implementation intentions intervention among nurses did not modify the notification rate of potential ocular tissue donors to donation stakeholders. Low exposure to the intervention was a major challenge in this study. Further studies should carefully consider a multicomponent intervention to increase exposure to this type of intervention. PMID:25132990

  16. Menthol attenuates respiratory irritation and elevates blood cotinine in cigarette smoke exposed mice.

    PubMed

    Ha, Michael A; Smith, Gregory J; Cichocki, Joseph A; Fan, Lu; Liu, Yi-Shiuan; Caceres, Ana I; Jordt, Sven Eric; Morris, John B

    2015-01-01

    Addition of menthol to cigarettes may be associated with increased initiation of smoking. The potential mechanisms underlying this association are not known. Menthol, likely due to its effects on cold-sensing peripheral sensory neurons, is known to inhibit the sensation of irritation elicited by respiratory irritants. However, it remains unclear whether menthol modulates cigarette smoke irritancy and nicotine absorption during initial exposures to cigarettes, thereby facilitating smoking initiation. Using plethysmography in a C57Bl/6J mouse model, we examined the effects of L-menthol, the menthol isomer added to cigarettes, on the respiratory sensory irritation response to primary smoke irritants (acrolein and cyclohexanone) and smoke of Kentucky reference 2R4 cigarettes. We also studied L-menthol's effect on blood levels of the nicotine metabolite, cotinine, immediately after exposure to cigarette smoke. L-menthol suppressed the irritation response to acrolein with an apparent IC₅₀ of 4 ppm. Suppression was observed even at acrolein levels well above those necessary to produce a maximal response. Cigarette smoke, at exposure levels of 10 mg/m³ or higher, caused an immediate and marked sensory irritation response in mice. This response was significantly suppressed by L-menthol even at smoke concentrations as high as 300 mg/m³. Counterirritation by L-menthol was abolished by treatment with a selective inhibitor of Transient Receptor Potential Melastatin 8 (TRPM8), the neuronal cold/menthol receptor. Inclusion of menthol in the cigarette smoke resulted in roughly a 1.5-fold increase in plasma cotinine levels over those observed in mice exposed to smoke without added menthol. These findings document that, L-menthol, through TRPM8, is a strong suppressor of respiratory irritation responses, even during highly noxious exposures to cigarette smoke or smoke irritants, and increases blood cotinine. Therefore, L-menthol, as a cigarette additive, may promote smoking initiation and nicotine addiction.

  17. Menthol Attenuates Respiratory Irritation and Elevates Blood Cotinine in Cigarette Smoke Exposed Mice

    PubMed Central

    Ha, Michael A.; Smith, Gregory J.; Cichocki, Joseph A.; Fan, Lu; Liu, Yi-Shiuan; Caceres, Ana I.; Jordt, Sven Eric; Morris, John B.

    2015-01-01

    Addition of menthol to cigarettes may be associated with increased initiation of smoking. The potential mechanisms underlying this association are not known. Menthol, likely due to its effects on cold-sensing peripheral sensory neurons, is known to inhibit the sensation of irritation elicited by respiratory irritants. However, it remains unclear whether menthol modulates cigarette smoke irritancy and nicotine absorption during initial exposures to cigarettes, thereby facilitating smoking initiation. Using plethysmography in a C57Bl/6J mouse model, we examined the effects of L-menthol, the menthol isomer added to cigarettes, on the respiratory sensory irritation response to primary smoke irritants (acrolein and cyclohexanone) and smoke of Kentucky reference 2R4 cigarettes. We also studied L-menthol’s effect on blood levels of the nicotine metabolite, cotinine, immediately after exposure to cigarette smoke. L-menthol suppressed the irritation response to acrolein with an apparent IC₅₀ of 4 ppm. Suppression was observed even at acrolein levels well above those necessary to produce a maximal response. Cigarette smoke, at exposure levels of 10 mg/m³ or higher, caused an immediate and marked sensory irritation response in mice. This response was significantly suppressed by L-menthol even at smoke concentrations as high as 300 mg/m³. Counterirritation by L-menthol was abolished by treatment with a selective inhibitor of Transient Receptor Potential Melastatin 8 (TRPM8), the neuronal cold/menthol receptor. Inclusion of menthol in the cigarette smoke resulted in roughly a 1.5-fold increase in plasma cotinine levels over those observed in mice exposed to smoke without added menthol. These findings document that, L-menthol, through TRPM8, is a strong suppressor of respiratory irritation responses, even during highly noxious exposures to cigarette smoke or smoke irritants, and increases blood cotinine. Therefore, L-menthol, as a cigarette additive, may promote smoking initiation and nicotine addiction. PMID:25679525

  18. Retinal tear presenting in a patient with ectrodactyly ectodermal dysplasia.

    PubMed

    Grogg, Jane Ann; Port, Nicholas; Graham, Trevor

    2014-04-01

    This article aims to report a case of known ectrodactyly ectodermal dysplasia in a young male patient who subsequently was found to have a retinal tear and localized retinal detachment. This is a case report of a 22-year-old white male patient with a history of ectrodactyly ectodermal dysplasia. Our patient initially presented with an acute exacerbation of bilateral, red, irritated eyes. No recent changes in vision were reported. The patient's ocular surface disease was consistent with ectrodermal dysplasia syndrome. However, a dilated fundus examination revealed an asymptomatic retinal tear with a surrounding localized retinal detachment. In this case, the patient presented with longstanding ocular surface disease known to be associated with this patient's inherited ectoderm disorder. In addition, this patient revealed a retinal tear, raising the possibility that patients with inherited congenital ectodermal dysplasia could be at risk for damaged structures originating from the neural ectoderm. In this heterogeneous disease, we are contributing to the existing literature a case of ectodermal dysplasia syndrome with obvious ectodermal complications that also had retinal findings leading us to speculate question if neural ectoderm could also be involved in this inherited disease.

  19. Solid lipid nanoparticles for ocular drug delivery.

    PubMed

    Seyfoddin, Ali; Shaw, John; Al-Kassas, Raida

    2010-01-01

    Ocular drug delivery remains challenging because of the complex nature and structure of the eye. Conventional systems, such as eye drops and ointments, are inefficient, whereas systemic administration requires high doses resulting in significant toxicity. There is a need to develop novel drug delivery carriers capable of increasing ocular bioavailability and decreasing both local and systemic cytotoxicity. Nanotechnology is expected to revolutionize ocular drug delivery. Many nano-structured systems have been employed for ocular drug delivery and yielded some promising results. Solid lipid nanoparticles (SLNs) have been looked at as a potential drug carrier system since the 1990s. SLNs do not show biotoxicity as they are prepared from physiological lipids. SLNs are especially useful in ocular drug delivery as they can enhance the corneal absorption of drugs and improve the ocular bioavailability of both hydrophilic and lipophilic drugs. SLNs have another advantage of allowing autoclave sterilization, a necessary step towards formulation of ocular preparations. This review outlines in detail the various production, characterization, sterilization, and stabilization techniques for SLNs. In-vitro and in-vivo methods to study the drug release profile of SLNs have been explained. Special attention has been given to the nature of lipids and surfactants commonly used for SLN production. A summary of previous studies involving the use of SLNs in ocular drug delivery is provided, along with a critical evaluation of SLNs as a potential ocular delivery system.

  20. Incorporation of liquid lipid in lipid nanoparticles for ocular drug delivery enhancement

    NASA Astrophysics Data System (ADS)

    Shen, Jie; Sun, Minjie; Ping, Qineng; Ying, Zhi; Liu, Wen

    2010-01-01

    The present work investigates the effect of liquid lipid incorporation on the physicochemical properties and ocular drug delivery enhancement of nanostructured lipid carriers (NLCs) and attempts to elucidate in vitro and in vivo the potential of NLCs for ocular drug delivery. The CyA-loaded or fluorescein-marked nanocarriers composed of Precifac ATO 5 and Miglyol 840 (as liquid lipid) were prepared by melting-emulsion technology, and the physicochemical properties of nanocarriers were determined. The uptake of nanocarriers by human corneal epithelia cell lines (SDHCEC) and rabbit cornea was examined. Ex vivo fluorescence imaging was used to investigate the ocular distribution of nanocarriers. The in vitro cytotoxicity and in vivo acute tolerance were evaluated. The higher drug loading capacity and improved in vitro sustained drug release behavior of lipid nanoparticles was found with the incorporation of liquid lipid in lipid nanoparticles. The uptake of nanocarriers by the SDHCEC was increased with the increase in liquid lipid loading. The ex vivo fluorescence imaging of the ocular tissues indicated that the liquid lipid incorporation could improve the ocular retention and penetration of ocular therapeutics. No alternation was macroscopically observed in vivo after ocular surface exposure to nanocarriers. These results indicated that NLC was a biocompatible and potential nanocarrier for ocular drug delivery enhancement.

  1. The mucosal surfaces of both eyes are immunologically linked by a neurogenic inflammatory reflex involving TRPV1 and substance P.

    PubMed

    Guzmán, Mauricio; Miglio, Maximiliano S; Zgajnar, Nadia R; Colado, Ana; Almejún, María B; Keitelman, Irene A; Sabbione, Florencia; Fuentes, Federico; Trevani, Analía S; Giordano, Mirta N; Galletti, Jeremías G

    2018-06-04

    Immunological interdependence between the two eyes has been reported for the cornea and the retina but not for the ocular mucosal surface. Intriguingly, patients frequently report ocular surface-related symptoms in the other eye after unilateral ocular surgery. Here we show how unilateral eye injuries in mice affect the mucosal immune response of the opposite ocular surface. We report that, despite the lack of lymphatic cross-drainage, a neurogenic inflammatory reflex in the contralateral conjunctiva is sufficient to increase, first, epithelial nuclear factor kappa B signaling, then, dendritic cell maturation, and finally, expansion of effector, instead of regulatory, T cells in the draining lymph node, leading to disrupted ocular mucosal tolerance. We also show that damage to ocular surface nerves is required. Using pharmacological inhibitors and agonists, we identified transient receptor potential vanilloid 1 (TRPV1) channel as the receptor sensing tissue damage in the injured eye and substance P released in the opposite ocular surface as the effector of the sympathetic response. Finally, blocking either step prevented subsequent ocular allergic reactions in the opposite eye in a unilateral corneal alkali burn model. This study demonstrates that both ocular surfaces are immunologically linked and suggests potential therapeutic targets for intervention.

  2. Influenza Virus Respiratory Infection and Transmission Following Ocular Inoculation in Ferrets

    PubMed Central

    Belser, Jessica A.; Gustin, Kortney M.; Maines, Taronna R.; Pantin-Jackwood, Mary J.; Katz, Jacqueline M.; Tumpey, Terrence M.

    2012-01-01

    While influenza viruses are a common respiratory pathogen, sporadic reports of conjunctivitis following human infection demonstrates the ability of this virus to cause disease outside of the respiratory tract. The ocular surface represents both a potential site of virus replication and a portal of entry for establishment of a respiratory infection. However, the properties which govern ocular tropism of influenza viruses, the mechanisms of virus spread from ocular to respiratory tissue, and the potential differences in respiratory disease initiated from different exposure routes are poorly understood. Here, we established a ferret model of ocular inoculation to explore the development of virus pathogenicity and transmissibility following influenza virus exposure by the ocular route. We found that multiple subtypes of human and avian influenza viruses mounted a productive virus infection in the upper respiratory tract of ferrets following ocular inoculation, and were additionally detected in ocular tissue during the acute phase of infection. H5N1 viruses maintained their ability for systemic spread and lethal infection following inoculation by the ocular route. Replication-independent deposition of virus inoculum from ocular to respiratory tissue was limited to the nares and upper trachea, unlike traditional intranasal inoculation which results in virus deposition in both upper and lower respiratory tract tissues. Despite high titers of replicating transmissible seasonal viruses in the upper respiratory tract of ferrets inoculated by the ocular route, virus transmissibility to naïve contacts by respiratory droplets was reduced following ocular inoculation. These data improve our understanding of the mechanisms of virus spread following ocular exposure and highlight differences in the establishment of respiratory disease and virus transmissibility following use of different inoculation volumes and routes. PMID:22396651

  3. Changes to the ocular biota with time in extended- and daily-wear disposable contact lens use.

    PubMed

    Stapleton, F; Willcox, M D; Fleming, C M; Hickson, S; Sweeney, D F; Holden, B A

    1995-11-01

    Gram-negative bacteria may play a role in the etiology of certain soft contact lens (SCL)-related diseases. Contact lens (CL) wear may modify the normal ocular biota, providing a more favorable environment for potential pathogens. This study reports temporal changes in ocular biota in daily-wear (DW) and extended-wear (EW) disposable SCL use in experienced and neophyte wearers. Lid margin and bulbar conjunctival biota were sampled prior to CL fitting in 26 previous DW SCL users, 18 previous EW SCL users, and 26 neophytes. Wearers were fitted with an etafilcon A CL in one eye and a polymacon CL in the fellow eye. Lenses were worn on a daily basis by the 26 previous DW SCL wearers and on an EW basis by the remaining 44 subjects. The ocular biota was further sampled after 1, 3, 6, 9, and 12 months of wear. The ocular biota consisted of coagulase-negative staphylococci, Corynebacterium spp., Micrococcus spp., and Propionibacterium spp. Potential pathogens were rarely isolated at baseline. No significant trend of increasing ocular colonization was shown for extended CL wear. Lid and conjunctival colonization increased with DW SCL use (P < 0.001), although this increase occurred for nonpathogenic species only. Fewer potential pathogens were isolated from DW SCL than from EW SCL users (P < 0.05). The lid margin consistently showed greater colonization than the conjunctiva and may be a source of potential pathogens during CL wear. Hydrogel CL wear appears to modify the ocular biota. An increased number of commensal organisms were present in DW SCL use. EW SCL use altered the spectrum of organisms isolated. These alterations may suppress the normal ocular defense mechanisms and may be relevant in the pathogenesis of CL-related disease.

  4. Changes to the ocular biota with time in extended- and daily-wear disposable contact lens use.

    PubMed Central

    Stapleton, F; Willcox, M D; Fleming, C M; Hickson, S; Sweeney, D F; Holden, B A

    1995-01-01

    Gram-negative bacteria may play a role in the etiology of certain soft contact lens (SCL)-related diseases. Contact lens (CL) wear may modify the normal ocular biota, providing a more favorable environment for potential pathogens. This study reports temporal changes in ocular biota in daily-wear (DW) and extended-wear (EW) disposable SCL use in experienced and neophyte wearers. Lid margin and bulbar conjunctival biota were sampled prior to CL fitting in 26 previous DW SCL users, 18 previous EW SCL users, and 26 neophytes. Wearers were fitted with an etafilcon A CL in one eye and a polymacon CL in the fellow eye. Lenses were worn on a daily basis by the 26 previous DW SCL wearers and on an EW basis by the remaining 44 subjects. The ocular biota was further sampled after 1, 3, 6, 9, and 12 months of wear. The ocular biota consisted of coagulase-negative staphylococci, Corynebacterium spp., Micrococcus spp., and Propionibacterium spp. Potential pathogens were rarely isolated at baseline. No significant trend of increasing ocular colonization was shown for extended CL wear. Lid and conjunctival colonization increased with DW SCL use (P < 0.001), although this increase occurred for nonpathogenic species only. Fewer potential pathogens were isolated from DW SCL than from EW SCL users (P < 0.05). The lid margin consistently showed greater colonization than the conjunctiva and may be a source of potential pathogens during CL wear. Hydrogel CL wear appears to modify the ocular biota. An increased number of commensal organisms were present in DW SCL use. EW SCL use altered the spectrum of organisms isolated. These alterations may suppress the normal ocular defense mechanisms and may be relevant in the pathogenesis of CL-related disease. PMID:7591092

  5. Efficacy and tolerability of brinzolamide/brimonidine suspension and prostaglandin analogs in patients previously treated with dorzolamide/timolol solution and prostaglandin analogs.

    PubMed

    Lo, Jonathan S; Pang, Pierre M; Lo, Samuel C

    2016-01-01

    Fixed combination glaucoma medication is increasingly used in glaucoma treatment. There is a lack of comparative study in the literature of non-beta blocker combination agents used adjunctively with a glaucoma agent in a different class. The objective of this study is to evaluate the effect of intraocular pressure (IOP) control and tolerability of non-beta blocker combination suspension with prostaglandin analogs (PGA) in patients with open angle glaucoma who were previously treated with beta blocker combination solution with PGA. Open-label retrospective review of patient records. This study looked at patients with open angle glaucoma taking dorzolamide/timolol solution with PGA that were switched to brinzolamide/brimonidine combination suspension with PGA. This study reviewed the charts of all patients who were at least 21 years old with a clinical diagnosis of open-angle glaucoma or ocular hypertension in at least one eye. Patients needed to have been treated with concomitant use of PGA and dorzolamide/timolol solution for at least one month. Patients using dorzolamide/timolol solution plus PGA with medication related ocular irritation were switched to brinzolamide/brimonidine suspension with the same PGA. Best-corrected visual acuity, ocular hyperemia grading, slit lamp biomicroscopy and Goldmann applanation tonometry measurements, and patient medication preferences were assessed at baseline, 1 month and 3 months. Forty eyes with open angle glaucoma. The mean age of the patients was 68 and 60% were females. The IOP before the switch was 17.2 and 16.5 (P=0.70) following the switch at 3 months. We found a decreasing trend of ocular hyperemia (P=0.064) and strong preference (P=0.011) for non-beta blocker combination suspension but no difference of visual acuity and slit lamp findings. Brinzolamide/brimonidine combination suspension when used adjunctively with PGA is equally effective. Patients in this study reported greatly reduced ocular redness and shorter duration of stinging with non-beta blocker combination suspension. Their preference of it over dorzolamide/timolol combination solution makes it a viable treatment option, particularly for the aging glaucoma patient with comorbidities that restrict the beta blocker use.

  6. Effect of benzalkonium chloride-free latanoprost ophthalmic solution on ocular surface in patients with glaucoma.

    PubMed

    Walimbe, Tejaswini; Chelerkar, Vidya; Bhagat, Purvi; Joshi, Abhijeet; Raut, Atul

    2016-01-01

    Benzalkonium chloride (BAK), included as a preservative in many topical treatments for glaucoma, induces significant toxicity and alters tear breakup time (TBUT). BAK-containing latanoprost, an ester prodrug of prostaglandin F2α, can cause ocular adverse events (AEs) associated with BAK. The purpose of this study was to evaluate the efficacy and safety of BAK-free latanoprost. A prospective, open-label, single-arm, multicenter, 8-week study in patients with primary open-angle glaucoma or ocular hypertension taking BAK-containing latanoprost for ≥12 months was performed. Patients were switched to BAK-free latanoprost ophthalmic solution 0.005% administered once daily, and eyes were assessed after 28 and 56 days. Primary efficacy and safety variables were TBUT and treatment-emergent AEs, respectively. At day 56, 40 eyes were evaluable. Mean TBUT increased significantly from baseline (3.67±1.60 seconds) to 5.03±2.64 and 6.06±3.39 seconds after 28 and 56 days of treatment with BAK-free latanoprost (P<0.0001). Ocular Surface Disease Index(©) (OSDI(©)) score also decreased significantly to 12.06±13.40 and 7.06±10.75 at 28 and 56 days, respectively, versus baseline (18.09±18.61, P<0.0001). In addition, inferior corneal staining score decreased significantly to 0.53 from baseline (0.85, P=0.0033). A reduction in conjunctival hyperemia and intraocular pressure was observed at both time points. No treatment-related serious AEs were evident and 12 (26.08%) treatment-emergent AEs occurred in seven patients, with eye pain and irritation being the most frequent. No clinically significant changes in vital signs or slit lamp examinations were observed. Results indicate that switching from BAK-containing latanoprost to BAK-free latanoprost resulted in significant improvements in TBUT, OSDI(©) score, and inferior corneal staining score, and measurable reductions in conjunctival hyperemia score. Furthermore, BAK-free latanoprost was well tolerated with only mild-to-moderate and self-limiting AEs. BAK-free latanoprost appears to be effective in protecting ocular surface integrity in glaucoma patients but further studies are needed to confirm this beneficial effect.

  7. BMY 30047: A novel topically active retinoid with low local and systemic toxicity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nair, X.; Quigley, J.; Tramposch, K.M.

    In the treatment of various dermatological disorders, topically applied retinoids have potential therapeutic use with the advantage of improved localized activity and lower toxicity over systemically administered retinoids. However, most retinoids cause a significant degree of local irritation. In the present study, the ability to produce local activity with low local irritation potential was evaluated with a novel retinoic acid derivative. BMY 30047 (11-cis, 13-cis-12-hydroxymethylretinoic acid delta-lactone) is one of a series of retinoic acid derivatives in which the carboxyl function of the polar end was modified with the aim of achieving reduced local irritation and systemic toxicity while retainingmore » the local therapeutic effect. BMY 30047 was evaluated and compared with all-trans retinoic acid for topical retinoid activity in several preclinical assay systems, including the utricle reduction assay in rhino mice, 12-o-tetradecanoylphorbol 13-acetate ester-stimulated ornithine decarboxylase induction in hairless mice and the UV light-induced photodamaged skin model in hairless mice. BMY 30047 was assessed for retinoid-type side effects by evaluating the skin irritation potential in rabbits after repeated topical application, and hypervitaminosis A-inducing potential in mice after i.p. injection. BMY 30047 demonstrated significant topical retinoid activity in several in vivo models with less skin irritation potential relative to the most used clinical concentrations of all-trans retinoic acid. BMY 30047 also showed very little systemic activity and did not produce any evidence of hypervitaminosis A syndrome at systemic doses 20 times greater than the no-effect dose of all-trans retinoic acid.« less

  8. Non-Animal Testing Approach to EPA Labeling for Eye Irritation

    EPA Pesticide Factsheets

    This document is an update to EPA’s 2013 published alternative testing approach (using in vitro/ex vivo assays) for determination of eye irritation potential in the pesticide program under EPA's classification and labeling system.

  9. Ocular surface injury from a microwave superheated liquid.

    PubMed

    Gagnon, Michael R; Walter, Keith A

    2004-03-01

    To describe the ocular surface injury resulting from a microwave superheated liquid. Case report. A 40-year-old man sustained an ocular surface injury from a microwave superheated liquid. The injury resulted in limbal stem cell damage requiring an autograft limbal stem cell transplantation. We are unaware of previous reports of microwave superheated liquids resulting in ocular injury. Microwave superheating of liquids is a potential ocular danger that should be brought to the attention of both ophthalmologists and their patients.

  10. Managing Sjögren’s Syndrome and non-Sjögren Syndrome dry eye with anti-inflammatory therapy

    PubMed Central

    Coursey, Terry G; de Paiva, Cintia S

    2014-01-01

    Dry eye from Sjögren’s syndrome is a multifactorial disease that results in dysfunction of the lacrimal functional unit. Studies have shown changes in tear composition, including inflammatory cytokines, chemokines, and metalloproteinase. T-lymphocytes have been shown to increase in the conjunctiva and lacrimal glands in patient and animal models. This inflammation is in part responsible for the pathogenesis of the disease, which results in symptoms of eye irritation, ocular surface epithelial disease, and loss of corneal barrier function. There are a number of anti-inflammatory approaches for treating this disease. The current study reviews details of immune response and anti–inflammatory therapies used to control this disease. PMID:25120351

  11. Topical Imiquimod in the Treatment of Conjunctival Actinic Keratosis.

    PubMed

    Rowlands, Megan A; Giacometti, Joseph N; Servat, Javier; Materin, Miguel A; Levin, Flora

    Conjunctival actinic keratosis is rare and difficult to treat, as recurrences are common. Imiquimod, an immune response modulator, is currently Food and Drug Administration-approved for cutaneous actinic keratosis and superficial basal cell carcinomas. Emerging reports have shown it to be effective in treating some periocular and conjunctival lesions. The authors present a case of a 68-year-old white man with recurrent actinic keratosis involving the pretarsal conjunctiva, which was successfully treated with 5% topical imiquimod following previous failure with cryotherapy and interferon α-2b. The patient had ocular irritation that resolved on cessation of treatment. To the authors' knowledge, this is the first report of conjunctival actinic keratosis being treated with and successfully eradicated by topical imiquimod.

  12. Safety Assessment of Alkyl PEG Sulfosuccinates as Used in Cosmetics.

    PubMed

    Johnson, Wilbur; Heldreth, Bart; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2015-09-01

    The Cosmetic Ingredient Review (CIR) Expert Panel (Panel) reviewed the safety of alkyl polyethylene glycol (PEG) sulfosuccinates, which function in cosmetics mostly as surfactants/cleansing agents. Although these ingredients may cause ocular and skin irritation, dermal penetration is unlikely because of the substantial polarity and molecular size of these ingredients. The Panel considered the negative oral carcinogenicity and reproductive and developmental toxicity data on chemically related laureths (PEG lauryl ethers) and negative repeated dose toxicity and skin sensitization data on disodium laureth sulfosuccinate supported the safety of these alkyl PEG sulfosuccinates in cosmetic products, but. The CIR Expert Panel concluded that the alkyl PEG sulfosuccinates are safe in the present practices of use and concentration when formulated to be nonirritating. © The Author(s) 2015.

  13. Estimation of the chemical-induced eye injury using a weight-of-evidence (WoE) battery of 21 artificial neural network (ANN) c-QSAR models (QSAR-21): part I: irritation potential.

    PubMed

    Verma, Rajeshwar P; Matthews, Edwin J

    2015-03-01

    Evaluation of potential chemical-induced eye injury through irritation and corrosion is required to ensure occupational and consumer safety for industrial, household and cosmetic ingredient chemicals. The historical method for evaluating eye irritant and corrosion potential of chemicals is the rabbit Draize test. However, the Draize test is controversial and its use is diminishing - the EU 7th Amendment to the Cosmetic Directive (76/768/EEC) and recast Regulation now bans marketing of new cosmetics having animal testing of their ingredients and requires non-animal alternative tests for safety assessments. Thus, in silico and/or in vitro tests are advocated. QSAR models for eye irritation have been reported for several small (congeneric) data sets; however, large global models have not been described. This report describes FDA/CFSAN's development of 21 ANN c-QSAR models (QSAR-21) to predict eye irritation using the ADMET Predictor program and a diverse training data set of 2928 chemicals. The 21 models had external (20% test set) and internal validation and average training/verification/test set statistics were: 88/88/85(%) sensitivity and 82/82/82(%) specificity, respectively. The new method utilized multiple artificial neural network (ANN) molecular descriptor selection functionalities to maximize the applicability domain of the battery. The eye irritation models will be used to provide information to fill the critical data gaps for the safety assessment of cosmetic ingredient chemicals. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Evaluation of electric arc furnace-processed steel slag for dermal corrosion, irritation, and sensitization from dermal contact.

    PubMed

    Suh, Mina; Troese, Matthew J; Hall, Debra A; Yasso, Blair; Yzenas, John J; Proctor, Debora M

    2014-12-01

    Electric arc furnace (EAF) steel slag is alkaline (pH of ~11-12) and contains metals, most notably chromium and nickel, and thus has potential to cause dermal irritation and sensitization at sufficient dose. Dermal contact with EAF slag occurs in many occupational and environmental settings because it is used widely in construction and other industrial sectors for various applications including asphaltic paving, road bases, construction fill, and as feed for cement kilns construction. However, no published study has characterized the potential for dermal effects associated with EAF slag. To assess dermal irritation, corrosion and sensitizing potential of EAF slag, in vitro and in vivo dermal toxicity assays were conducted based on the Organisation for Economic Co-operation and Development (OECD) guidelines. In vitro dermal corrosion and irritation testing (OECD 431 and 439) of EAF slag was conducted using the reconstructed human epidermal (RHE) tissue model. In vivo dermal toxicity and delayed contact sensitization testing (OECD 404 and 406) were conducted in rabbits and guinea pigs, respectively. EAF slag was not corrosive and not irritating in any tests. The results of the delayed contact dermal sensitization test indicate that EAF slag is not a dermal sensitizer. These findings are supported by the observation that metals in EAF slag occur as oxides of low solubility with leachates that are well below toxicity characteristic leaching procedure (TCLP) limits. Based on these results and in accordance to the OECD guidelines, EAF slag is not considered a dermal sensitizer, corrosive or irritant. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Additive impairment of the barrier function and irritation by biogenic amines and sodium lauryl sulphate: a controlled in vivo tandem irritation study.

    PubMed

    Fluhr, J W; Kelterer, D; Fuchs, S; Kaatz, M; Grieshaber, R; Kleesz, P; Elsner, P

    2005-01-01

    Biogenic amines are potential irritants e.g. in fish-, meat-, milk- and egg-processing professions like cooks, butchers and bakers. The aim of this study was to test the irritative and barrier-disrupting properties of the biogenic amines ammonium hydroxide (AM), dimethylamine (DMA) and trimethylamine (TMA). A repeated sequential irritation of 30 min twice per day was performed over a total of 4 days (tandem repeated irritation test) on the back of 20 healthy volunteers of both sexes with AM, DMA, TMA and sodium lauryl sulphate (SLS). The epidermal barrier function was assessed with a Tewameter TM 210, stratum corneum surface pH was measured with a Skin-pH-Meter 900, inflammation was assessed with a Chromameter CR-300 on the a* axis for redness and a visual score was recorded. All tested biogenic amines (AM, DMA and TMA) induced a barrier disruption and a pH increase paralleled with a 1-day-delayed onset of inflammatory signs. These effects were further enhanced and accelerated by a sequential application of SLS together with the biogenic amines, and inflammation occurred earlier than with the single compounds. Acetic acid (AA) in contrast did only show mild barrier disruption and no significant inflammatory signs. Our system allowed a ranking of the different compounds in their irritative potential in the tandem irritation with SLS: SLS > NaOH > TMA > AA > AM > DMA. The results are suggestive that in the food-processing industry the simultaneous contact with biogenic amines and harmful detergents like SLS should be minimized. Copyright 2005 S. Karger AG, Basel.

  16. Dry eye syndrome among computer users

    NASA Astrophysics Data System (ADS)

    Gajta, Aurora; Turkoanje, Daniela; Malaescu, Iosif; Marin, Catalin-Nicolae; Koos, Marie-Jeanne; Jelicic, Biljana; Milutinovic, Vuk

    2015-12-01

    Dry eye syndrome is characterized by eye irritation due to changes of the tear film. Symptoms include itching, foreign body sensations, mucous discharge and transitory vision blurring. Less occurring symptoms include photophobia and eye tiredness. Aim of the work was to determine the quality of the tear film and ocular dryness potential risk in persons who spend more than 8 hours using computers and possible correlations between severity of symptoms (dry eyes symptoms anamnesis) and clinical signs assessed by: Schirmer test I, TBUT (Tears break-up time), TFT (Tear ferning test). The results show that subjects using computer have significantly shorter TBUT (less than 5 s for 56 % of subjects and less than 10 s for 37 % of subjects), TFT type II/III in 50 % of subjects and type III 31% of subjects was found when compared to computer non users (TFT type I and II was present in 85,71% of subjects). Visual display terminal use, more than 8 hours daily, has been identified as a significant risk factor for dry eye. It's been advised to all persons who spend substantial time using computers to use artificial tears drops in order to minimize the symptoms of dry eyes syndrome and prevents serious complications.

  17. Open source modular ptosis crutch for the treatment of myasthenia gravis.

    PubMed

    Saidi, Trust; Sivarasu, Sudesh; Douglas, Tania S

    2018-02-01

    Pharmacologic treatment of Myasthenia Gravis presents challenges due to poor tolerability in some patients. Conventional ptosis crutches have limitations such as interference with blinking which causes ocular surface drying, and frequent irritation of the eyes. To address this problem, a modular and adjustable ptosis crutch for elevating the upper eyelid in Myasthenia Gravis patients has been proposed as a non-surgical and low-cost solution. Areas covered: This paper reviews the literature on the challenges in the treatment of Myasthenia Gravis globally and focuses on a modular and adjustable ptosis crutch that has been developed by the Medical Device Laboratory at the University of Cape Town. Expert commentary: The new medical device has potential as a simple, effective and unobtrusive solution to elevate the drooping upper eyelid(s) above the visual axis without the need for medication and surgery. Access to the technology is provided through an open source platform which makes it available globally. Open access provides opportunities for further open innovation to address the current limitations of the device, ultimately for the benefit not only of people suffering from Myasthenia Gravis but also of those with ptosis from other aetiologies.

  18. Sensory irritation and incapacitation evoked by thermal decomposition products of polymers and comparisons with known sensory irritants.

    PubMed

    Barrow, C S; Alarie, Y; Stock, M F

    1978-01-01

    A decrease in respiratory rate in mice during exposure to irritating airborne chemicals has been utilized as a response parameter to characterize the degree of upper respiratory tract irritation (sensory irritation) to the thermal decomposition products of various polymers. These included polystyrene, polyvinyl chloride, flexible polyurethane foam, polytetrafluorethylene, a fiber glass reinforced polyester resin, and Douglas Fir. Each of the materials was thermally decomposed in a low-mass vertical furnace in an air atmosphere at a programmed heating rate of 20 degrees C/min. Mice, in groups of four, were exposed to graded concentrations of the thermal decomposition products of each of the above materials. Dose-response curves were obtained by utilizing the maximum percent decrease in respiratory rate as the response parameter during each exposure. Comparison of these dose-response curves with other sensory irritants such as chlorine, ammonia, hydrogen chloride, sulfur dioxide, and toluene diisocyanate gave an indication of the sensory irrtation potential of the thermal decomposition products of these various polymers versus that of well-known single airborne chemical irritants. Total stress and incapacitation of the organism during exposure to sensory irritants such as from the thermal decomposition products of synthetic polymers is discussed.

  19. Quantitative analysis of tear film fluorescence and discomfort during tear film instability and thinning.

    PubMed

    Begley, Carolyn; Simpson, Trefford; Liu, Haixia; Salvo, Eliza; Wu, Ziwei; Bradley, Arthur; Situ, Ping

    2013-04-12

    The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P < 0.05). The rate of increasing discomfort during trials was highly correlated with the rate of decrease in median PI and developing TBU (Spearman's, r ≥ 0.70). Significant correlations were found between corneal fluorescence, MBI, and sensory measures. Concentration quenching of fluorescein dye with tear film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.

  20. Ocular hazards of the colors used during the festival-of-colors (Holi) in India--malachite green toxicity.

    PubMed

    Velpandian, T; Saha, K; Ravi, A K; Kumari, S S; Biswas, N R; Ghose, S

    2007-01-10

    The objective of this study was to evaluate the nature of the colors used and their toxicity to the eye upon exposure to them during celebration of Holi (our festival-of-colors). Color powders and formulations were procured at random in and around Delhi during the festival. The green/bluish-green colors reported with the higher incidence of ocular toxicity were subjected for further evaluation. Eyewash fluid collected from the patients exposed to the colors was also subjected for analysis. This study was further extended to evaluate the corneal penetration of malachite green using goat cornea in perfusion chamber. In 16/18 color samples collected, malachite green or 4-[(4-dimethylaminophenyl)-phenyl-methyl]-N,N-dimethyl-aniline was detected at different concentrations. In the eyewash fluid of four patients, HPLC estimation confirmed the presence of malachite green at concentrations of 1.3, 0.18, 3.5 and 5.4 microg in 250 ml which was responsible for its reported toxicity. The in vitrotrans-corneal penetration studies did not show any detectable amount of malachite green in effluent fluid-in vitro tissue retention studies revealed that increasing the contact time increases tissue concentration. After 2 min of exposure, the tissue concentration was significantly higher. To conclude, malachite green was extensively used in our festival of Holi and has caused severe ocular irritation with epithelial defect upon exposure, though it did not penetrate through the cornea-further in vitro and in vivo studies are required on colors used in Holi.

  1. A novel technique of contrast-enhanced optical coherence tomography imaging in evaluation of clearance of lipids in human tears.

    PubMed

    Napoli, Pietro Emanuele; Coronella, Franco; Satta, Giovanni Maria; Fossarello, Maurizio

    2014-01-01

    The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be achieved by this simple approach.

  2. Immunophenotyping does not improve predictivity of the local lymph node assay in mice.

    PubMed

    Strauss, Volker; Kolle, Susanne N; Honarvar, Naveed; Dammann, Martina; Groeters, Sibylle; Faulhammer, Frank; Landsiedel, Robert; van Ravenzwaay, Bennard

    2015-04-01

    The local lymph node assay (LLNA) is a regulatory accepted test for the identification of skin sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. However, there is evidence that LLNA is overestimating the sensitization potential of certain substance classes in particular those exerting skin irritation. Some reports describe the additional use of flow cytometry-based immunophenotyping to better discriminate irritants from sensitizing irritants in LLNA. In the present study, the 22 performance standards plus 8 surfactants were assessed using the radioactive LLNA method. In addition, lymph node cells were immunophenotyped to evaluate the specificity of the lymph node response using cell surface markers such as B220 or CD19, CD3, CD4, CD8, I-A(κ) and CD69 with the aim to allow a better discrimination above all between irritants and sensitizers, but also non-irritating sensitizers and non-sensitizers. However, the markers assessed in this study do not sufficiently differentiate between irritants and irritant sensitizers and therefore did not improve the predictive capacity of the LLNA. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Acute Toxicity and Dermal and Eye Irritation of the Aqueous and Hydroalcoholic Extracts of the Seeds of "Zapote" Pouteria mammosa (L.) Cronquist.

    PubMed

    Dutok, Carlos M S; Berenguer-Rivas, Clara Azalea; Rodríguez-Leblanch, Elizabeth; Pérez-Jackson, Liliana; Chil-Nuñez, Idelsy; Escalona-Arranz, Julio César; Reyes-Tur, Bernardo; Queiroz, Margareth M C

    2015-01-01

    The common use of Pouteria mammosa (L.) Cronquist, "Mamey or Zapote," in food and ethnobotanic medicine shows its low or absent toxicity as fruit extracts prepared from seeds. However, it is essential to conduct security trials to scientifically support their use in drug therapy. This study evaluated the aqueous and hydroalcoholic extract (25%) Acute Oral Toxicity, obtained from the seeds of P. mammosa, in Sprague Dawley rats and dermal and eye irritability in New Zealand rabbits. The 404 and 405 acute dermal and eye irritation/corrosion guidelines were used, as well as the 423 Acute Oral Toxicity guideline, Acute Toxic Class Method of the Organization for Economic Cooperation and Development (OECD). The aqueous extract was located in the following category: not classified as toxic (CTA 5), while hydroalcoholic extract at 25% was classified as dangerous (CTA 4). Both extracts can be used without side reaction that irritates the skin which permitted classification as potentially not irritant. P. mammosa in the two extracts caused mild and reversible eye irritation, and it was classified as slightly irritating.

  4. Toxicity evaluation of the photoprotective compound LQFM048: Eye irritation, skin toxicity and genotoxic endpoints.

    PubMed

    de Ávila, Renato Ivan; de Sousa Vieira, Marcelo; Gaeti, Marilisa Pedroso Nogueira; Moreira, Larissa Cleres; de Brito Rodrigues, Laís; de Oliveira, Gisele Augusto Rodrigues; Batista, Aline Carvalho; Vinhal, Daniela Cristina; Menegatti, Ricardo; Valadares, Marize Campos

    2017-02-01

    A new molecule, LQFM048, originally designed through molecular hybridization using green chemistry approach, is in development as a photoprotective agent. Eye irritation, skin toxicity and genotoxicity evaluations are mandatory for predicting health risks. In this context, the purpose of this study was to investigate the eye irritation potential of LQFM048 by combining Short Time Exposure (STE), Bovine Corneal Opacity and Permeability (BCOP) associated with corneal histomorphometry and Hen's Egg Test-Chorioallantoic Membrane (HET-CAM). Additionally, skin toxicity was evaluated by interleukin-18 production in the HaCaT keratinocyte, Local Lymph Node Assay (LLNA:BrdU-ELISA) method, 3T3 Neutral red uptake (NRU) assay and in vivo phototoxicity test. Genotoxic potential of LQFM048 was also analyzed by cytokinesis-block micronucleus assay (MNvit test-cytoB) in HepG2 cells. Our results showed that LQFM048 did not induce eye irritation and it was classified as UN GHS No Category for both STE and BCOP assays and non-irritating for HET-CAM test. LQFM048 showed non-potential skin sensitization with stimulation index (SI=0.7) in the LLNA:BrdU-ELISA method. Corroborating in vivo tests, it did not promote significant cytotoxicity in HaCaT cells and it showed similar levels of IL-18 when compared to control. Furthermore, LQFM048 induced non-phototoxic potential with photo-irritation factor (PIF) and mean photo effect (MPE) of 1 and -0.138, respectively, for 3T3 cells. Similarly, it was not phototoxic for in vivo testing with or without exposure to UVA, showing SI values of 1 and 1.2, respectively. The micronucleus test showed that LQFM048 was not genotoxic, under the conditions tested.In conclusion, LQFM048, a heterocyclic compound obtained through an environmentally acceptable simple synthetic route, seems to be safe for human use, especially for the development of a new sunscreen product, since it is neither an eye irritant, nor a contact allergen, nor mutagenic and nor phototoxic. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Should patients with ocular genetic disorders have genetic testing?

    PubMed

    Zanolli, Mario T; Khetan, Vikas; Dotan, Gad; Pizzi, Laura; Levin, Alex V

    2014-09-01

    To discuss the risks, benefits and value of genetic testing for ocular genetic disease. Testing for ocular genetics diseases is becoming more available and successful gene therapy is being reported. Clinicians must prepare for this trend by considering diagnostic genetic testing for their patients. As advances continually occur in genetic testing for ocular genetic disorders, clinicians must develop an understanding of the potential risks and benefits for their patients.

  6. Final report on the safety assessment of Triethylene Glycol and PEG-4.

    PubMed

    2006-01-01

    Triethylene Glycol and PEG-4 (polyethylene glycol) are polymers of ethylene oxide alcohol. Triethylene Glycol is a specific three-unit chain, whereas PEG-4 is a polymer with an average of four units, but may contain polymers ranging from two to eight ethylene oxide units. In the same manner, other PEG compounds, e.g., PEG-6, are mixtures and likely contain some Triethylene Glycol and PEG-4. Triethylene Glycol is a fragrance ingredient and viscosity decreasing agent in cosmetic formulations, with a maximum concentration of use of 0.08% in skin-cleansing products. Following oral doses, Triethylene Glycol and its metabolites are excreted primarily in urine, with small amounts released in feces and expired air. With oral LD50 values in rodents from 15 to 22 g/kg, this compound has little acute toxicity. Rats given short term oral doses of 3% in water showed no signs of toxicity, whereas all rats given 10% died by the 12th day of exposure. At levels up to 1 g/m3, rats exposed to aerosolized Triethylene Glycol for 6 h per day for 9 days showed no signs of toxicity. Rats fed a diet containing 4% Triethylene Glycol for 2 years showed no signs of toxicity. There were no treatment-related effects on rats exposed to supersaturated Triethylene Glycol vapor for 13 months nor in rats that consumed 0.533 cc Triethylene Glycol per day in drinking water for 13 months. Triethylene Glycol was not irritating to the skin of rabbits and produced only minimal injury to the eye. In reproductive and developmental toxicity studies in rats and mice, Triethylene Glycol did not produce biologically significant embryotoxicity or teratogenicity. However, some maternal toxicity was seen in dams given 10 ml/kg/day during gestation. Triethylene Glycol was not mutagenic or genotoxic in Ames-type assays, the Chinese hamster ovary mutation assay, and the sister chromatid exchange assays. PEG-4 is a humectant and solvent in cosmetic products, with a maximum concentration of use of 20% in the "other manicuring preparations" product category. This ingredient, with an oral LD50 in rats of 32.77 g/kg, has low acute toxicity. Rats given up to 50,000 ppm PEG-4 in drinking water for 5 days showed no permanent signs of toxicity. Rats given daily oral doses up to 2 g/kg/day of PEG-4 for 33 days showed no signs of toxicity. Undiluted PEG-4 produced only minimal injury to the rabbit eye. PEG-4 was not mutagenic in Ames-type assays, did not induce chromosome aberration in an in vivo bone marrow assay, and was negative for genotoxicity in a dominant lethal assay using rats. Other PEG compounds, which have previously been reviewed by the Cosmetic Ingredient Review (CIR) Expert Panel, e.g., PEG-6, are mixtures that likely include Triethylene Glycol and PEG-4, so these data were also considered. PEG-6 and PEG-8 were not dermal irritants in several rabbit studies. PEG-2 Stearate had a potential for slight irritation in rabbits but was not a sensitizer in guinea pigs. PEG-2 Cocamine was a moderate irritant in rabbits, producing severe erythema. In one dermal study, PEG-2 Cocamine was determined to be corrosive to rabbit skin, causing eschar and necrosis. PEG-6 and PEG-8 caused little to no ocular irritation. PEG-8 was not mutagenic or genotoxic in a Chinese hamster ovary assay, a sister-chromatid exchange assay, and in an unscheduled DNA synthesis assay. In clinical studies on normal skin, PEG-6 and PEG-8 caused mild cases of immediate hypersensitivity; PEG-8 was not a sensitizer; PEG-2 Stearate was not an irritant, a sensitizer, or a photosensitizer; and PEG-6 Stearate was not an irritant or sensitizer. In damaged skin, cases of systemic toxicity and contact dermatitis in burn patients were attributed to a PEG-based topical ointment. The CIR Expert Panel acknowledged the lack of dermal sensitization data for Triethylene Glycol and dermal irritation and sensitization data for PEG-4. That PEG-6, PEG-8, and PEG-2 Stearate were not irritants or sensitizers suggested that Triethylene Glycol and PEG-4 also would not be irritants or sensitizers, and the absence of any reported reactions in the case literature and the professional experience of the Expert Panel further supported the absence of any significant sensitization potential. The need for additional data to demonstrate the safety of PEGs Cocamine was related to the Cocamine moiety and is not relevant here. The Panel reminded formulators of cosmetic products that, as with other PEG compounds, Triethylene Glycol and PEG-4 should not be used on damaged skin because of cases of systemic toxicity and contact dermatitis in burn patients have been attributed to a PEG-based topical ointment. Based on its consideration of the available information, the CIR Expert Panel concluded that Triethylene Glycol and PEG-4 are safe as cosmetic ingredients in the present practices and concentrations of use as described in this safety assessment.

  7. The toxicity of picaridin containing insect repellent reported to the National Poison Data System.

    PubMed

    Charlton, Nathan P; Murphy, Lauren T; Parker Cote, Jennifer L; Vakkalanka, J Priyanka

    2016-09-01

    While low toxicity is reported, there are sparse data on the safety of acute picaridin (icaridin) exposures in humans. The purpose of this study was to review National Poison Data System (NPDS) data regarding ingestion of insect repellents containing picaridin and compare those to insect repellents containing DEET and other insect repellents not containing DEET. NPDS was queried for single agent human insect repellent ingestions reported between 1 January 2000 and 31 May 2015 using the American Association of Poison Control Center generic categories 201048 (Insect Repellents with DEET) and 201049 (Insect Repellents without DEET). Picaridin-containing product exposures were assessed using Poisindex(®) product ID 6744589. Insect repellents of unknown type were not included. 68,429 exposures occurred; 24% were non-DEET-containing products, of which 2% were picaridin-containing products. Among picaridin exposures, 92.9% were managed outside of a health-care facility; there were no reported cases of major effect or death, and only one case of moderate effect. Primary symptoms across all insect repellent exposures included ocular irritation/pain, vomiting, red eye/conjunctivitis, and oral irritation. Treatment primarily included dilution/irrigation/wash. Unintentional ingestion of picaridin-containing and other insect repellents was associated only with minor toxicity and was generally managed outside of a health-care facility.

  8. Prediction of ocular irritancy of 26 chemicals and 26 cosmetic products with isolated rabbit eye (IRE) test.

    PubMed

    Guo, Xiang; Yang, Xing Fen; Yang, Ying; Hans, Raabe; Cai, Jing Heng; Xue, Jin Yu; Tan, Xiao Hua; Xie, Xiao Ping; Xiong, Xi Kun; Huang, Jun Ming

    2012-06-01

    This study aims to establish and evaluate the methodology of isolated rabbit eye (IRE) test. IRE test was performed according to modifications of the in vitro toxicology (INVITTOX) Protocol No.85: Rabbit enucleated eye test by European Centre for the Validation of Alternative Methods (ECVAM), and then 26 chemicals and 26 cosmetic products were tested in both in vitro IRE and in vivo Draize tests. A statistical analysis was conducted to determine the relevance of the IRE test to the data generated in the Draize test. IRE test was established successfully in our laboratory. It was shown that ranking correlation and class concordance were fairly well between the IRE test and the Draize test for 26 reference chemicals (Fisher's Exact Test χ(2)=51.314, P<0.001; McNemar P=0.261; Gamma=0.960, P<0.001; Kappa=0.843, P<0.001) and 26 cosmetic products (Fisher's Exact Test χ(2)=15.522, P<0.001; McNemar P=0.311; Gamma=0.967, P<0.001; Kappa=0.611, P<0.001). IRE test was established successfully for in vitro testing of eye irritation as an alternative to Draize test. Copyright © 2012 The Editorial Board of Biomedical and Environmental Sciences. Published by Elsevier B.V. All rights reserved.

  9. Short Time Exposure (STE) test in conjunction with Bovine Corneal Opacity and Permeability (BCOP) assay including histopathology to evaluate correspondence with the Globally Harmonized System (GHS) eye irritation classification of textile dyes.

    PubMed

    Oliveira, Gisele Augusto Rodrigues; Ducas, Rafael do Nascimento; Teixeira, Gabriel Campos; Batista, Aline Carvalho; Oliveira, Danielle Palma; Valadares, Marize Campos

    2015-09-01

    Eye irritation evaluation is mandatory for predicting health risks in consumers exposed to textile dyes. The two dyes, Reactive Orange 16 (RO16) and Reactive Green 19 (RG19) are classified as Category 2A (irritating to eyes) based on the UN Globally Harmonized System for classification (UN GHS), according to the Draize test. On the other hand, animal welfare considerations and the enforcement of a new regulation in the EU are drawing much attention in reducing or replacing animal experiments with alternative methods. This study evaluated the eye irritation of the two dyes RO16 and RG19 by combining the Short Time Exposure (STE) and the Bovine Corneal Opacity and Permeability (BCOP) assays and then comparing them with in vivo data from the GHS classification. The STE test (first level screening) categorized both dyes as GHS Category 1 (severe irritant). In the BCOP, dye RG19 was also classified as GHS Category 1 while dye RO16 was classified as GHS no prediction can be made. Both dyes caused damage to the corneal tissue as confirmed by histopathological analysis. Our findings demonstrated that the STE test did not contribute to arriving at a better conclusion about the eye irritation potential of the dyes when used in conjunction with the BCOP test. Adding the histopathology to the BCOP test could be an appropriate tool for a more meaningful prediction of the eye irritation potential of dyes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Taxanes: vesicants, irritants, or just irritating?

    PubMed

    Barbee, Meagan S; Owonikoko, Taofeek K; Harvey, R Donald

    2014-01-01

    Several classes of antineoplastic agents are universally referred to as vesicants with ample supporting literature. However, the literature surrounding the taxanes is controversial. While the American Society of Clinical Oncology and Oncology Nursing Society Chemotherapy Administration Safety Standards and the Chemotherapy and Biotherapy Guidelines and Recommendations for Practice identify the risks of extravasation and the parameters surrounding the infusion of known vesicants, recommend administration sites for known agents, and recommend antidotes for particular extravasation cases, they fail to provide specific recommendations for the administration of individual taxanes, or a classification system for antineoplastic agents as vesicants, irritants, or inert compounds. There is also a lack of prescribing information regarding such recommendations. The lack of a formal classification system further complicates the accurate delineation of vesicant antineoplastic agents and subsequent appropriate intravenous administration and extravasation management. There are several factors that make the classification of taxanes as vesicants or irritants challenging. Comprehensive preclinical data describing potential mechanisms of tissue damage or vesicant-like properties are lacking. Furthermore, most case reports of taxane extravasation fail to include the parameters surrounding administration, such as the concentration of medication and duration of infusion, making it difficult to set parameters for vesicant potential. Subsequently, many practitioners default to central venous administration of taxanes without evidence that such administration minimizes the risk of extravasation or improves outcomes thereof. Here, we review briefly the data surrounding taxane extravasation and potential vesicant or irritant properties, classify the taxanes, and propose a spectrum for antineoplastic agent potential to cause tissue injury that warrants clinical intervention if extravasation occurs.

  11. The Behind-the-Knee test: an efficient model for evaluating mechanical and chemical irritation.

    PubMed

    Farage, Miranda A

    2006-05-01

    The 'Behind-the-Knee' method (BTK test), using the popliteal fossa as a test site, evaluates both the inherent chemical irritation, and the potential for mechanical irritation of substrates and products. This approach eliminates some of the difficulties of in-use clinical test systems while still providing reliable results. In this publication, examples of the results of BTK tests on several materials are presented with direct comparisons, where possible, with results of in-use clinical testing conducted on the same materials. In in-use clinical tests, volunteer panelists were provided with catamenial products to use in place of their normal product. In the BTK test, samples were applied daily to the popliteal fossa using an elastic athletic band. In both studies, irritation reactions were scored visually. Levels of irritation in the BTK test are consistently higher than those of standard patch tests, illustrating the contribution of mechanical irritation to the overall irritant potential of materials and products. Repeated tests on identical test materials demonstrated that the BTK test results are reproducible. Side-by-side comparisons of the BTK test and in-use clinical tests demonstrated that the BTK test produces results of similar quality to the in-use clinical. By using several concurrent panels with a common test material, it is possible to compare the irritant properties of several materials at once. We have tested over 25 different materials in over 35 BTK studies. The test method has proven reliable and versatile in testing a wide variety of materials, including menstrual pads, topsheets, interlabial pads, pantiliners, tampons and lotion coatings on products. Unlike in-use clinicals, the BTK test allows the direct comparison of two products at one time on the same individual, and is easily adapted to investigative programs. It is subject to fewer confounding factors, is much easier to implement, has a shorter turnaround time, and is less expensive than in-use clinical testing. Importantly, unlike standard patch tests, the BTK test evaluates both the inherent chemical irritation associated with materials and the mechanical irritation owing to friction. Although the BTK test was developed using catamenial products, the test system provides a valuable alternative for evaluating any material where mechanical irritation may play a role, including textiles, facial tissues, baby and adult diapers, and laundry products that may leave residues on fabrics.

  12. Irritancy ranking of 31 cleansers in the Indian market in a 24-h patch test.

    PubMed

    Lakshmi, C; Srinivas, C R; Anand, C V; Mathew, A C

    2008-08-01

    Cleansing trends promise freshness, sensory and health benefits but may also be accompanied by an increase in soap-induced skin irritation. The aim of this study was to evaluate the irritant effect of 31 cleansers (28 bar soaps and 3 liquid cleansers) available in the Indian market. Eight percent w/v solutions of the soaps/cleansers were made and 30 microL of each of the solutions were applied to Finn chambers and occluded for 24 h along with distilled water (negative control) and 20% sodium dodecyl sulphate (SDS) as positive control. The sites were graded for erythema and scaling 30 min after removing the patches. The pH of each of the soap solutions was determined. Mean with SD and ANOVA (F-value) was computed separately for each soap/cleanser with respect to the two parameters, erythema and scaling. The total of the means for both the parameters, erythema and scaling was also computed. The cleansers were listed based on this total from the least irritant to the most irritant. The differences between soaps (F-value) was significant for erythema and scaling [erythema = 4.106 (P = 0.000); scaling = 6.006 (P = 0.000)]. Cetaphil cleansing lotion had the lowest erythema score of 0.25. Lowest scaling score of zero was recorded for Cetaphil cleansing lotion and Elovera moisturizing body wash. Aquasoft and Lifebuoy soaps had the highest erythema score of 2.13. Acnex had the highest scaling score of 1.75; Aquasoft, Hamam scrub bath soap and Naturepower sandal soaps were the next with a scaling score of 1.63. Cetaphil cleansing lotion, Aquaderm liquid soap, Dove bar soap and Elovera moisturizing body wash proved to be the least irritant cleansers with a total score of less than 1. The four most irritant soaps/cleansers had an average score of 3.65. The irritant potential of the majority of the cleansers fell between these extremes. The pH of all the soap/cleanser solutions was neutral to alkaline (pH 7-9) except that of Dove bar, Cetaphil cleansing lotion, Aquaderm liquid soap and Elovera moisturizing body wash which tested acidic (pH 5-6). The pH of the positive control--20% SDS, was acidic (pH 6). The difference in the irritancy potential between soaps/cleansers as determined by the 24-h patch test was significant. There were individual variations in the irritant potential of the soaps/cleansers in the volunteers, thus when the patient queries on what soap to use, it may be advisable to test each patient separately and educate him/her regarding the soaps/cleansers less likely to cause irritation. The limitations of the study was that it was single blind and non-randomized as all the 14 soap solutions were applied on 15 volunteers in the first panel and subsequently all the 17 soap solutions were applied on eight volunteers in the second panel. However, we could compare the irritant potential of 31 cleansers. The results of 24-h patch testing of 31 soaps/cleansers in the Indian market in two panels of 14 and 17 soaps/cleansers on 15 and eight volunteers, respectively, are presented.

  13. Non-occlusive topical exposure of human skin in vitro as model for cytotoxicity testing of irritant compounds.

    PubMed

    Lönnqvist, Susanna; Briheim, Kristina; Kratz, Gunnar

    2016-02-01

    Testing of irritant compounds has traditionally been performed on animals and human volunteers. Animal testing should always be restricted and for skin irritancy mice and rabbits hold poor predictive value for irritant potential in humans. Irritant testing on human volunteers is restricted by the duration subjects can be exposed, and by the subjectivity of interpreting the visual signs of skin irritation. We propose an irritant testing system using viable human full thickness skin with the loss of cell viability in the exposed skin area as end point measurement. Skin was exposed to sodium dodecyl sulfate (SDS) at 20% concentration by non-occluded topical exposure to establish a positive control response and subsequent test compounds were statistically compared with the 20% SDS response. Cell viability and metabolism were measured with 3-(4,5-dimethyl-thiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The model presents correlation between increased concentration of SDS and decreased viability of cells in the exposed skin area (R(2) = 0.76). We propose the model to be used for cytotoxicity testing of irritant compounds. With fully intact barrier function, the model comprises all cells present in the skin with quantifiable end point measurement.

  14. A new 3D reconstituted human corneal epithelium model as an alternative method for the eye irritation test.

    PubMed

    Jung, Kyoung-Mi; Lee, Su-Hyon; Ryu, Yang-Hwan; Jang, Won-Hee; Jung, Haeng-Sun; Han, Ju-Hee; Seok, Seung-Hyeok; Park, Jae-Hak; Son, Youngsook; Park, Young-Ho; Lim, Kyung-Min

    2011-02-01

    Many efforts are being made to develop new alternative in vitro test methods for the eye irritation test. Here we report a new reconstructed human corneal epithelial model (MCTT HCE model) prepared from primary-cultured human limbal epithelial cells as a new alternative in vitro eye irritation test method. In histological and immunohistochemical observation, MCTT HCE model displayed a morphology and biomarker expressions similar to intact human cornea. Moreover, the barrier function was well preserved as measured by high transepithelial electrical resistance, effective time-50 for Triton X-100, and corneal thickness. To employ the model as a new alternative method for eye irritation test, protocol refinement was performed and optimum assay condition was determined including treatment time, treatment volume, post-incubation time and rinsing method. Using the refined protocol, 25 reference chemicals with known eye irritation potentials were tested. With the viability cut-off value at 50%, chemicals were classified to irritant or non-irritant. When compared with GHS classification, the MCTT HCE model showed the accuracy of 88%, sensitivity of 100% and specificity of 77%. These results suggest that the MCTT HCE model might be useful as a new alternative eye irritation test method. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Indoor Air Quality and Asthma

    PubMed Central

    Holm, Stewart

    2017-01-01

    Numerous contaminants in indoor air and their potential to cause or exacerbate asthma continue to be a subject of public health concern. Many agents are causally associated with or can exacerbate asthma, particularly in children. For formaldehyde, an established respiratory irritant based on numerous studies, the evidence for an association with asthma is still considered only limited or suggestive. However, there is no evidence that indicates increased sensitivity to sensory irritation to formaldehyde in people often regarded as susceptible such as asthmatics. Acrolein, but not formaldehyde, was significantly associated with asthma in a large cohort of children. This prompted an evaluation of this highly irritating chemical that had never previously been considered in the context of the indoor air/childhood asthma issue. Because acrolein is more potent than formaldehyde as a respiratory irritant and ubiquitous in indoor air, it is plausible that previous studies on potential risk factors and childhood asthma may be confounded by formaldehyde acting as an unrecognized proxy for acrolein. PMID:28250718

  16. Ocular hemodynamics and glaucoma: the role of mathematical modeling.

    PubMed

    Harris, Alon; Guidoboni, Giovanna; Arciero, Julia C; Amireskandari, Annahita; Tobe, Leslie A; Siesky, Brent A

    2013-01-01

    To discuss the role of mathematical modeling in studying ocular hemodynamics, with a focus on glaucoma. We reviewed recent literature on glaucoma, ocular blood flow, autoregulation, the optic nerve head, and the use of mathematical modeling in ocular circulation. Many studies suggest that alterations in ocular hemodynamics play a significant role in the development, progression, and incidence of glaucoma. Although there is currently a limited number of studies involving mathematical modeling of ocular blood flow, regulation, and diseases (such as glaucoma), preliminary modeling work shows the potential of mathematical models to elucidate the mechanisms that contribute most significantly to glaucoma progression. Mathematical modeling is a useful tool when used synergistically with clinical and laboratory data in the study of ocular blood flow and glaucoma. The development of models to investigate the relationship between ocular hemodynamic alterations and glaucoma progression will provide a unique and useful method for studying the pathophysiology of glaucoma.

  17. MRI in ocular drug delivery

    PubMed Central

    Li, S. Kevin; Lizak, Martin J.; Jeong, Eun-Kee

    2008-01-01

    Conventional pharmacokinetic methods for studying ocular drug delivery are invasive and cannot be conveniently applied to humans. The advancement of MRI technology has provided new opportunities in ocular drug-delivery research. MRI provides a means to non-invasively and continuously monitor ocular drug-delivery systems with a contrast agent or compound labeled with a contrast agent. It is a useful technique in pharmacokinetic studies, evaluation of drug-delivery methods, and drug-delivery device testing. Although the current status of the technology presents some major challenges to pharmaceutical research using MRI, it has a lot of potential. In the past decade, MRI has been used to examine ocular drug delivery via the subconjunctival route, intravitreal injection, intrascleral injection to the suprachoroidal space, episcleral and intravitreal implants, periocular injections, and ocular iontophoresis. In this review, the advantages and limitations of MRI in the study of ocular drug delivery are discussed. Different MR contrast agents and MRI techniques for ocular drug-delivery research are compared. Ocular drug-delivery studies using MRI are reviewed. PMID:18186077

  18. Role of macromolecules in the safety of use of body wash cosmetics.

    PubMed

    Bujak, Tomasz; Wasilewski, Tomasz; Nizioł-Łukaszewska, Zofia

    2015-11-01

    One of the most challenging problems related to the use of surfactants in body wash cosmetics is their potential to cause skin irritations. Surfactants can bind with proteins, remove lipids from the epidermal surface, contribute to the disorganization of liquid crystal structures in the intercellular lipids, and interact with living skin cells. These processes can lead to skin irritations and allergic reactions, and impair the epidermal barrier function. The present study is an attempt to assess the effect of polymers and hydrolysed proteins present in the formulations of model body wash cosmetics on product properties. Special attention was given to the safety of use of this product type. The study examined three macromolecules: polyvinylpyrrolidone (PVP), hydrolysed wheat protein (HWP) and polyvinylpyrrolidone/hydrolysed wheat protein crosspolymer (PVP/HWP). The addition of the substances under study was found to improve the foaming properties of body wash cosmetics, increase their stability during storage, and contribute significantly to an improvement in the safety of product use by reducing the irritant potential. The strongest ability to reduce the skin irritation potential was determined for the formula enriched with the PVP/HWP crosspolymer. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Topical anesthetic abuse keratitis secondary to floppy eyelid syndrome.

    PubMed

    Goldich, Yakov; Zadok, David; Avni, Isaac; Hartstein, Morris

    2011-01-01

    To report the diagnosis and management of a patient with chronic ophthalmic topical anesthetic abuse and floppy eyelid syndrome. We describe the case of a 47-year-old man suffering from persistent bilateral ocular irritation and chronic corneal erosions. The patient was hospitalized in our ophthalmology department and underwent thorough ophthalmic, systemic, and psychiatric evaluation. Chronic topical anesthetic abuse was discovered. Removal of abused drops and copious lubricating treatment lead to partial improvement further permitting diagnosis of floppy eyelid syndrome. Definitive surgical treatment by horizontal eyelid tightening combined with continuous lubrication resulted in remission of symptoms. Uncommon conditions may coexist in 1 patient. In this case, floppy eyelid syndrome resulted in topical anesthetic abuse. Ophthalmologists should keep both these conditions in mind when treating patients with otherwise unexplained chronic persistent corneal erosions.

  20. Correlates of Irritability in College Students With Depressive Symptoms

    PubMed Central

    Pedrelli, Paola; Nyer, Maren; Holt, Daphne; Bakow, Brianna R.; Fava, Maurizio; Baer, Lee; Cassiello, Clair; Mulligan, Maura; Cusin, Cristina; Farabaugh, Amy

    2015-01-01

    Depression is a prevalent psychiatric disorder associated with significant personal and societal burden. There is accumulating evidence for the presence of a subtype of depression characterized by the presence of irritability that is associated with increased morbidity, risk for suicidal ideation, and functional impairments in adults. Little is known about the features of depressive symptoms with and without irritability among young adults in college. The primary aim of this study was to characterize the presentation of college students with depressive symptoms and irritability. Two-hundred eighty-seven undergraduate college students with depressive symptoms with and without irritability were compared across several psychiatric and functional outcome variables. Independent samples t-tests or logistic regressions were conducted for each outcome variable using the irritability item of the Beck Depression Inventory as a dichotomous grouping variable. Analyses were conducted separately for the men and the women. Both male and female students with depressive symptoms and severe irritability reported a greater severity of depressive symptoms compared with their peers with no or mild irritability. In the women, the presence of irritability was associated with greater symptoms of anxiety, whereas in the men, it was associated with increased likelihood of engaging in risky behaviors, including compulsive use of alcohol, illicit drugs, and prescription drugs. The male and female college students with depressive symptoms with and without irritability did not differ on severity of suicidal ideation, hopelessness, or cognitive functioning. The findings from this study suggest that depressive symptoms and irritability may characterize a subtype of college students who have a greater symptom burden and with the potential need for more aggressive and prompt treatment. PMID:24177482

  1. Effects of job-related stress and burnout on asthenopia among high-tech workers.

    PubMed

    Ostrovsky, Anat; Ribak, Joseph; Pereg, Avihu; Gaton, Dan

    2012-01-01

    Eye- and vision-related symptoms are the most frequent health problems among computer users. The findings of eye strain, tired eyes, eye irritation, burning sensation, redness, blurred vision and double vision, when appearing together, have recently been termed 'computer vision syndrome', or asthenopia. To examine the frequency and intensity of asthenopia among individuals employed in research and development departments of high-tech firms and the effects of job stress and burnout on ocular complaints, this study included 106 subjects, 42 high-tech workers (study group) and 64 bank employees (control group). All participants completed self-report questionnaires covering demographics, asthenopia, satisfaction with work environmental conditions, job-related stress and burnout. There was a significant between-group difference in the intensity of asthenopia, but not in its frequency. Burnout appeared to be a significant contributing factor to the intensity and frequency of asthenopia. This study shows that burnout is a significant factor in asthenopic complaints in high-tech workers. This manuscript analyses the effects of psychological environmental factors, such as job stress and burnout, on ocular complaints at the workplace of computer users. The findings may have an ergonomic impact on how to improve health, safety and comfort of the working environment among computer users, for better perception of the job environment, efficacy and production.

  2. Treatment of Dry Eye Disease.

    PubMed

    Marshall, Leisa L; Roach, J Michael

    2016-02-01

    Review of the etiology, clinical manifestations, and treatment of dry eye disease (DED). Articles indexed in PubMed (National Library of Medicine), Iowa Drug Information Service (IDIS), and the Cochrane Reviews and Trials in the last 10 years using the key words "dry eye disease," "dry eye syndrome," "dry eye and treatment." Primary sources were used to locate additional resources. Sixty-eight publications were reviewed, and criteria supporting the primary objective were used to identify useful resources. The literature included practice guidelines, book chapters, review articles, original research articles, and product prescribing information for the etiology, clinical manifestations, diagnosis, and treatment of DED. DED is one of the most common ophthalmic disorders. Signs and symptoms of DED vary by patient, but may include ocular irritation, redness, itching, photosensitivity, visual blurring, mucous discharge, and decreased tear meniscus or break-up time. Symptoms improve with treatment, but the condition is not completely curable. Treatment includes reducing environmental causes, discontinuing medications that cause or worsen dry eye, and managing contributing ocular or systemic conditions. Most patients use nonprescription tear substitutes, and if these are not sufficient, other treatment is prescribed. These treatments include the ophthalmic anti-inflammatory agent cyclosporine, punctal occlusion, eye side shields, systemic cholinergic agents, and autologous serum tears. This article reviews the etiology, symptoms, and current therapy for DED.

  3. Visual Fatigue Induced by Viewing a Tablet Computer with a High-resolution Display.

    PubMed

    Kim, Dong Ju; Lim, Chi Yeon; Gu, Namyi; Park, Choul Yong

    2017-10-01

    In the present study, the visual discomfort induced by smart mobile devices was assessed in normal and healthy adults. Fifty-nine volunteers (age, 38.16 ± 10.23 years; male : female = 19 : 40) were exposed to tablet computer screen stimuli (iPad Air, Apple Inc.) for 1 hour. Participants watched a movie or played a computer game on the tablet computer. Visual fatigue and discomfort were assessed using an asthenopia questionnaire, tear film break-up time, and total ocular wavefront aberration before and after viewing smart mobile devices. Based on the questionnaire, viewing smart mobile devices for 1 hour significantly increased mean total asthenopia score from 19.59 ± 8.58 to 22.68 ± 9.39 (p < 0.001). Specifically, the scores for five items (tired eyes, sore/aching eyes, irritated eyes, watery eyes, and hot/burning eye) were significantly increased by viewing smart mobile devices. Tear film break-up time significantly decreased from 5.09 ± 1.52 seconds to 4.63 ± 1.34 seconds (p = 0.003). However, total ocular wavefront aberration was unchanged. Visual fatigue and discomfort were significantly induced by viewing smart mobile devices, even though the devices were equipped with state-of-the-art display technology. © 2017 The Korean Ophthalmological Society

  4. Liquid Nitrogen Cryotherapy for Conjunctival Lymphangiectasia: A Case Series

    PubMed Central

    Fraunfelder, Frederick W.

    2009-01-01

    Purpose: To report a case series of conjunctival lymphangiectasia treated with liquid nitrogen cryotherapy. Methods: A 1.5-mm Brymill cryoprobe was applied in a double freeze-thaw method after an incisional biopsy of a portion of the conjunctiva in patients with conjunctival lymphangiectasia. Freeze times were 1 to 2 seconds with thawing of 5 to 10 seconds between treatments. Patients were reexamined at 1 day, 2 weeks, 3 months, 6 months, and yearly following cryotherapy. Results: Five eyes of 4 patients (3 male and 1 female) with biopsy-proven conjunctival lymphangiectasia underwent liquid nitrogen cryotherapy. The average patient age was 53 years. Ocular examination revealed large lymphatic vessels that were translucent and without conjunctival injection. Subjective symptoms included epiphora, ocular irritation, eye redness, and occasional blurred vision. After treatment with liquid nitrogen cryotherapy, the patients’ symptoms and signs resolved within 2 weeks. Lymphangiectasia recurred twice in one patient, at 1 and 3 years postoperatively. In another patient, lymphangiectasia recurred at 6 months. The average time to recurrence in these 3 eyes was 18 months. Average length of follow-up was 24.5 months for all subjects. Conclusion: Liquid nitrogen cryotherapy may be an effective surgical alternative in the treatment of conjunctival lymphangiectasia. Cryotherapy may need to be repeated in some instances. PMID:20126499

  5. Visual Fatigue Induced by Viewing a Tablet Computer with a High-resolution Display

    PubMed Central

    Kim, Dong Ju; Lim, Chi-Yeon; Gu, Namyi

    2017-01-01

    Purpose In the present study, the visual discomfort induced by smart mobile devices was assessed in normal and healthy adults. Methods Fifty-nine volunteers (age, 38.16 ± 10.23 years; male : female = 19 : 40) were exposed to tablet computer screen stimuli (iPad Air, Apple Inc.) for 1 hour. Participants watched a movie or played a computer game on the tablet computer. Visual fatigue and discomfort were assessed using an asthenopia questionnaire, tear film break-up time, and total ocular wavefront aberration before and after viewing smart mobile devices. Results Based on the questionnaire, viewing smart mobile devices for 1 hour significantly increased mean total asthenopia score from 19.59 ± 8.58 to 22.68 ± 9.39 (p < 0.001). Specifically, the scores for five items (tired eyes, sore/aching eyes, irritated eyes, watery eyes, and hot/burning eye) were significantly increased by viewing smart mobile devices. Tear film break-up time significantly decreased from 5.09 ± 1.52 seconds to 4.63 ± 1.34 seconds (p = 0.003). However, total ocular wavefront aberration was unchanged. Conclusions Visual fatigue and discomfort were significantly induced by viewing smart mobile devices, even though the devices were equipped with state-of-the-art display technology. PMID:28914003

  6. Liquid nitrogen cryotherapy for conjunctival lymphangiectasia: a case series.

    PubMed

    Fraunfelder, Frederick W

    2009-12-01

    To report a case series of conjunctival lymphangiectasia treated with liquid nitrogen cryotherapy. A 1.5-mm Brymill cryoprobe was applied in a double freeze-thaw method after an incisional biopsy of a portion of the conjunctiva in patients with conjunctival lymphangiectasia. Freeze times were 1 to 2 seconds with thawing of 5 to 10 seconds between treatments. Patients were reexamined at 1 day, 2 weeks, 3 months, 6 months, and yearly following cryotherapy. Five eyes of 4 patients (3 male and 1 female) with biopsy-proven conjunctival lymphangiectasia underwent liquid nitrogen cryotherapy. The average patient age was 53 years. Ocular examination revealed large lymphatic vessels that were translucent and without conjunctival injection. Subjective symptoms included epiphora, ocular irritation, eye redness, and occasional blurred vision. After treatment with liquid nitrogen cryotherapy, the patients' symptoms and signs resolved within 2 weeks. Lymphangiectasia recurred twice in one patient, at 1 and 3 years postoperatively. In another patient, lymphangiectasia recurred at 6 months. The average time to recurrence in these 3 eyes was 18 months. Average length of follow-up was 24.5 months for all subjects. Liquid nitrogen cryotherapy may be an effective surgical alternative in the treatment of conjunctival lymphangiectasia. Cryotherapy may need to be repeated in some instances.

  7. Orbital extraskeletal osteosarcoma following enucleation in a cat: a case report.

    PubMed

    Groskopf, Brooke S; Dubielzig, Richard R; Beaumont, Stephanie L

    2010-05-01

    We present a unique case of a feline orbital extraskeletal osteosarcoma that developed 5 years post-enucleation. In 2002, an ophthalmologist enucleated the left eye of a 2-year-old neutered male DSH and submitted it to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW). COPLOW diagnosed the left eye with feline diffuse iris melanoma. In June 2007, the cat presented to another veterinarian for moderate swelling of the enucleation site. Palpation suggested a firm mass along the lateral orbital rim and an exploratory orbitotomy revealed a cyst with a mass adhered to it and the ventrolateral orbital rim. The cyst and mass were excised by the veterinarian and submitted to COPLOW. COPLOW diagnosed the tissue as an orbital conjunctival inclusion cyst and an acquired orbital osteosarcoma. Following the enucleation, retained conjunctival epithelium became embedded in the connective tissue of the orbit and caused a cyst to develop. The cyst wall consisted of a myofibroblastic collagen-rich matrix and acted as a nidus of chronic irritation and tumor growth. This orbital osteosarcoma resembles feline vaccine-associated sarcomas (VAS), feline post-traumatic ocular sarcomas, and microchip-associated sarcomas in terms of it histopathology and its hypothesized pathogenesis related to exposure to antigenic material such as implanted epithelium, lens protein, vaccine components, and microchips as foreign bodies.

  8. Gut microbiota influences low fermentable substrate diet efficacy in children with irritable bowel syndrome

    USDA-ARS?s Scientific Manuscript database

    We sought to determine whether a low fermentable substrate diet (LFSD) decreases abdominal pain frequency in children with irritable bowel syndrome (IBS) and to identify potential microbial factors related to diet efficacy. Pain symptoms, stooling characteristics, breath hydrogen and methane, whole ...

  9. Final report on the safety assessment of Calendula officinalis extract and Calendula officinalis.

    PubMed

    2001-01-01

    Calendula Officinalis Extract is an extract of the flowers of Calendula officinalis, the common marigold, whereas Calendula Officinalis is described as plant material derived from the flowers of C. officinalis. Techniques for preparing Calendula Officinalis Extract include gentle disintegration in soybean oil. Propylene glycol and butylene glycol extractions were also reported. Components of these ingredients are variously reported to include sugars, carotenoids, phenolic acids, sterols, saponins, flavonoids, resins, sterins, quinones, mucilages, vitamins, polyprenylquinones, and essential oils. Calendula Officinalis Extract is reported to be used in almost 200 cosmetic formulations, over a wide range of product categories. There are no reported uses of Calendula Officinalis. Acute toxicity studies in rats and mice indicate that the extract is relatively nontoxic. Animal tests showed at most minimal skin irritation, and no sensitization or phototoxicity. Minimal ocular irritation was seen with one formulation and no irritation with others. Six saponins isolated from C. officinalis flowers were not mutagenic in an Ames test, and a tea derived from C. officinalis was not genotoxic in Drosophila melanogaster. No carcinogenicity or reproductive and developmental toxicity data were available. Clinical testing of cosmetic formulations containing the extract elicited little irritation or sensitization. Absent any basis for concluding that data on one member of a botanical ingredient group can be extrapolated to another in a group, or to the same ingredient extracted differently, these data were not considered sufficient to assess the safety of these ingredients. Additional data needs include current concentration of use data; function in cosmetics; ultraviolet (UV) absorption data; if absorption occurs in the UVA or UVB range, photosensitization data are needed; gross pathology and histopathology in skin and other major organ systems associated with repeated dermal exposures; dermal reproductive/developmental toxicity data; inhalation toxicity data, especially addressing the concentration, amount delivered, and particle size; and genotoxicity testing in a mammalian system; if positive, a 2-year dermal carcinogenicity assay performed using National Toxicology Program (NTP) methods is needed. Until these data are available, it is concluded that the available data are insufficient to support the safety of these ingredients in cosmetic formulations.

  10. Emerging ocular biomarkers of Alzheimer disease.

    PubMed

    van Wijngaarden, Peter; Hadoux, Xavier; Alwan, Mostafa; Keel, Stuart; Dirani, Mohamed

    2017-01-01

    Interest in reliable biomarkers of Alzheimer disease, the leading cause of dementia, has been fuelled by challenges in diagnosing the disease and monitoring disease progression as well as the response to therapy. A range of ocular manifestations of Alzheimer disease, including retinal and lens amyloid-beta accumulation, retinal nerve fiber layer loss, and retinal vascular changes, have been proposed as potential biomarkers of the disease. Herein, we examine the evidence regarding the potential value of these ocular biomarkers of Alzheimer disease. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  11. Development of an in vitro alternative assay method for vaginal irritation.

    PubMed

    Ayehunie, Seyoum; Cannon, Chris; Larosa, Karen; Pudney, Jeffrey; Anderson, Deborah J; Klausner, Mitchell

    2011-01-11

    The vaginal mucosa is commonly exposed to chemicals and therapeutic agents that may result in irritation and/or inflammation. In addition to acute effects, vaginal irritation and inflammation can make women more susceptible to infections such as HIV-1 and herpes simplex virus 2 (HSV-2). Hence, the vaginal irritation potential of feminine care formulations and vaginally administered therapeutic agents is a significant public health concern. Traditionally, testing of such materials has been performed using the rabbit vaginal irritation (RVI) assay. In the current study, we investigated whether the organotypic, highly differentiated EpiVaginal™ tissue could be used as a non-animal alternative to the RVI test. The EpiVaginal tissue was exposed to a single application of ingredients commonly found in feminine hygiene products and the effects on tissue viability (MTT assay), barrier disruption (measured by transepithelial electrical resistance, TEER and sodium fluorescein (NaFl) leakage), and inflammatory cytokine release (interleukin (IL)-1α, IL-1β, IL-6, and IL-8) patterns were examined. When compared to untreated controls, two irritating ingredients, nonoxynol 9 and benzalkonium chloride, reduced tissue viability to <40% and TEER to <60% while increasing NaFl leakage by 11-24% and IL-1α and IL-1β release by >100%. Four other non-irritating materials had minimal effects on these parameters. Assay reproducibility was confirmed by testing the chemicals using three different tissue production lots and by using tissues reconstructed from cells obtained from three different donors. Coefficients of variation between tissue lots reconstructed with cells obtained from the same donor or lots reconstructed with cells obtained from different donors were less than 10% and 12%, respectively. In conclusion, decreases in tissue viability and barrier function and increases in IL-1α and IL-1β release appear to be useful endpoints for preclinical screening of topically applied chemicals and formulations for their vaginal irritation potential. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Ocular toxoplasmosis and retinal detachment: five case reports.

    PubMed

    Kianersi, F; Naderi Beni, A; Ghanbari, H; Fazel, F

    2012-10-01

    Ocular toxoplasmosis is a potentially blinding cause of posterior uveitis. Retinal detachment is rare complication of ocular toxoplasmosis. To report the clinical course and prognosis of retinal breaks and detachments occurring in patients with ocular toxoplasmosis. This study was a retrospective, non-comparative case series of five patients with ocular toxoplasmosis who had consulted us with retinal detachment. All of the participants had retinal detachment after severe and treatment resistant toxoplasmic retinochoroiditis, leaving one of them with decreased visual acuity to light perception in spite of treatment and final visual acuity was 20/100 or better in four patients. The functional prognosis for the patients with retinal detachment was poor. Careful retinal examination in ocular toxoplasmosis is warranted, especially in patients with severe intraocular inflammation.

  13. Increased gastrointestinal permeability and gut inflammation in children with functional abdominal pain and Irritable Bowel Syndrome

    USDA-ARS?s Scientific Manuscript database

    To determine gastrointestinal (GI) permeability and fecal calprotectin concentration in children 7 to 10 years of age with functional abdominal pain and irritable bowel syndrome (FAP/IBS) versus control subjects and ascertain potential relationships with pain symptoms and stooling, GI permeability a...

  14. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: skin irritation.

    PubMed

    Macfarlane, Martin; Jones, Penny; Goebel, Carsten; Dufour, Eric; Rowland, Joanna; Araki, Daisuke; Costabel-Farkas, Margit; Hewitt, Nicola J; Hibatallah, Jalila; Kirst, Annette; McNamee, Pauline; Schellauf, Florian; Scheel, Julia

    2009-07-01

    Evaluation of the skin irritancy and corrosivity potential of an ingredient is a necessity in the safety assessment of cosmetic ingredients. To date, there are two formally validated alternatives to the rabbit Draize test for skin corrosivity in place, namely the rat skin transcutaneous electrical resistance (TER) assay and the Human Skin Model Test using EpiSkin, EpiDerm and SkinEthic reconstructed human epidermal equivalents. For skin irritation, EpiSkin, EpiDerm and SkinEthic are validated as stand-alone test replacements for the rabbit Draize test. Data from these tests are rarely considered in isolation and are evaluated in combination with other factors to establish the overall irritating or corrosive potential of an ingredient. In light of the deadlines established in the Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. In conclusion, the safety assessments for skin irritation/corrosion of new chemicals for use in cosmetics can be confidently accomplished using exclusively alternative methods.

  15. Adapalene gel 0.1% is better tolerated than tretinoin gel 0.025% among healthy volunteers of various ethnic origins.

    PubMed

    Goh, Chee Leok; Tang, Mark B Y; Briantais, Philippe; Kaoukhov, Alexandre; Soto, Pascale

    2009-01-01

    The efficacious acne treatment adapalene gel 0.1% is significantly less irritating than tretinoin of various concentrations and formulations, according to several clinical studies conducted predominantly in Caucasian patients. To confirm the lower irritation potential of adapalene gel 0.1% compared to tretinoin gel 0.025% among volunteers of various ethnic origins and to explore the difference in the irritant susceptibility among ethnic groups. The study was a single-centre, randomized, investigator-masked and intra-individual comparison. Healthy volunteers applied adapalene and tretinoin daily to the face for 21 days and to the forearms for 4 days, and were then evaluated for the level of irritation. The irritation potential of adapalene gel 0.1% was significantly lower than that of tretinoin gel 0.025% in all tolerability assessments, irrespective of the volunteers' ethnic origins. The between-treatment differences were similar among various ethnic groups. Statistically significant but small inter-ethnicity differences were observed in the evaluation of facial signs, with Caucasians being less susceptible than Chinese, Asian Indians and Malays. Adapalene gel 0.1% was significantly better tolerated than tretinoin gel 0.025% among various ethnic groups. The patients' ethnic origins had no impact on the difference between adapalene and tretinoin treatments in terms of tolerability.

  16. [Rhinitis in adults].

    PubMed

    Kalogjera, Livije

    2011-01-01

    Rhinitis is a very common disorder caused by inflammation or irritation of nasal mucosa. Dominant symptoms are nasal obstruction; however, in some patients, runny nose, excessive sneezing or nasal itch may be the most bothersome symptoms. The most common causes of nasal inflammation are viral infections and allergic response to airborne allergens. Response to irritants may cause similar symptoms, although signs of inflammation may not always be present. Viral rhinitis is lasting up to 10 days and it is part of the common cold syndrome. In short-lived rhinitis, lasting for 7 to 10 days, sometimes it is not easy to differentiate between the potential causes of the disorder, if general symptoms of infection like fever and malaise are not present. In long-living rhinitis, it is important to differentiate between infectious, allergic, non-allergic non-infectious rhinitis, and chronic rhinosinusitis. Itch and ocular symptoms are more common in allergic rhinitis, while other symptoms like nasal obstruction, rhinorrhea and sneezing may affect patients with allergic and non-allergic rhinitis. Patients with allergic rhinitis often have symptoms after exposure to irritants, temperature and humidity changes, like patients with non-allergic rhinitis, and such exposure may sometimes cause more severe symptoms than exposure to allergens. Sensitivity to a non-specific trigger is usually called non-specific nasal hyperreactivity. Allergic rhinitis occurs due to immunoglobulin E (IgE) interaction with allergen in contact with nasal mucosa in a sensitized patient. Sensitization to certain airborne allergen, like pollens, dust, molds, animal dander, etc. usually occurs in families with allergy background, which is helpful in making diagnosis in patients who have rhinitis in a certain period of the year, or aggravation of nasal symptoms occurs in the environment typical of certain allergen. The diagnosis is clinically confirmed by proving sensitivity to certain allergen on skin prick test, and by proving specific antibody IgE in patient serum. Allergic rhinitis is categorized according to sensitivity to allergens that occur seasonally, like pollens, or to allergens that are present all year round, like house dust mite, molds and animal dander, into seasonal and perennial allergic rhinitis. Allergy to pollens causes the same mechanism of inflammation in response to allergens, which is the result of allergen binding to specific IgE antibody; however, patients with pollen allergy usually complain more of sneezing and runny nose, whereas patients with allergy to perennial allergens more often complain of obstruction, with the episodes of sneezing and runny nose occurring only when exposed to higher concentrations of allergens (house cleaning, around pets). Treatment includes avoidance of allergens, medical treatment and immunotherapy (allergy vaccines, tablets with allergens). Avoidance of allergens means reduction of environmental allergen load to the respiratory system including workplace, which is not easy to accomplish. Medical treatment is usually necessary to control symptoms, and it includes antihistamines, nasal or in tablets, and nasal glucocorticoids (steroids). Antihistamines should be second generation, which do not cause sedation, and such treatment shows more efficacy on runny nose, sneezing and nasal itch than on nasal stuffiness. Nasal steroids are more potent in improving nasal patency than antihistamines, and are at least as potent in the control of all other nasal and ocular symptoms. Nasal patency may be improved by nasal or oral decongestants, but such treatment should be reduced to as short period as possible, since after several days of using nasal decongestants rebound congestion may occur and patients will need nasal decongestants to improve nasal airways even when allergens are not around anymore.

  17. Safety and efficacy of a hydroxypropyl guar/polyethylene glycol/propylene glycol-based lubricant eye-drop in patients with dry eye.

    PubMed

    Labetoulle, Marc; Messmer, Elisabeth M; Pisella, Pierre-Jean; Ogundele, Abayomi; Baudouin, Christophe

    2017-04-01

    To demonstrate non-inferiority of a hydroxypropyl guar/polyethylene glycol/propylene glycol lubricating eye-drop (HPG/PEG/PG) compared with an osmoprotective carboxymethylcellulose/glycerine eye-drop (O/CMC) for ocular surface staining. This was a multicentre, randomised, observer-masked, parallel-group study. Adults with dry eye instilled HPG/PEG/PG/ or O/CMC 4 times daily for 35 days and then as needed through day 90. Total ocular surface staining (TOSS) score changes from baseline and Impact of Dry Eye on Everyday Life (IDEEL) treatment satisfaction module scores were assessed. Non-inferiority, based on TOSS score change from baseline, was concluded if the upper limit of the 2-sided CI was <2 units. Mean±SD patient age was 64.4±13.7 years; 94 patients were randomised to treatment (HPG/PEG/PG, n=46; O/CMC, n=48). Mean±SE TOSS score change from baseline to day 35 was -2.2±0.33 with HPG/PEG/PG and -1.7±0.47 with O/CMC (treatment difference, -0.47±0.47; p=0.38), and the non-inferiority criterion was met. IDEEL treatment satisfaction scores were similar between groups at day 35 and day 90. The most frequently reported adverse event was eye irritation (HPG/PEG/PG, n=2; O/CMC, n=3). HPG/PEG/PG and O/CMC reduced ocular surface damage, and HPG/PEG/PG was non-inferior to O/CMC. Both treatments were effective, convenient and well tolerated. NCT01863368, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Evaluation of Patients with Facial Palsy and Ophthalmic Sequelae: A 23-Year Retrospective Review.

    PubMed

    Joseph, Shannon S; Joseph, Andrew W; Smith, Jane I; Niziol, Leslie M; Musch, David C; Nelson, Christine C

    2017-10-01

    Facial palsy (FP) can result in serious ophthalmic sequelae including loss of vision. We describe the clinical characteristics of FP patients presenting for ophthalmologic evaluation and the timing for initiating ophthalmologic care. We performed a retrospective review of 96 consecutive FP patients presenting between 1992 and 2015 at a tertiary eye center. The main outcome measures were time interval from the diagnosis of FP and onset of ocular symptoms to the initial ophthalmologic evaluation (IOE), and the severity of exposure keratopathy and eyelid malposition on IOE. The median time interval from the diagnosis of FP to the IOE was 1.6 years (interquartile range; IQR = 0.5-9.2), and from the onset of ocular symptoms to IOE was 0.8 years (IQR = 0.3-2.3). The most common ocular symptoms were dryness (47.9%; n = 46), irritation (39.6%; n = 38), and tearing (30.2%; n = 29). A total of 26.0% (n = 25) of patients were bothered by the appearance of their eyes. Only 13.5% (n = 13) noted change in vision. On IOE, 81.6% (n = 75) of patients had punctate epithelial erosions (PEE), of which 52.3% (n = 35) had moderate to severe PEE, 3.3% (n = 3) had corneal ulcers and 2.2% (n = 2) had corneal abrasions. The average margin-reflex distance 2 was 6.4 mm (SD = 2.4) with average lagophthalmos of 3.5 mm (SD = 3.1). Among FP patients presenting for ophthalmologic evaluation, exposure keratopathy (as evidenced by PEE and corneal ulcers/abrasions) is highly prevalent and moderately severe on IOE, despite only 13.5% of patients noting decreased vision. These findings underscore the importance of timely and thorough ophthalmologic evaluation of FP patients.

  19. Use of in vitro methods to rank surfactants for irritation potential in support of new product development.

    PubMed

    Casterton, P L; Potts, L F; Klein, B D

    1994-08-01

    11 surfactant raw materials with potential applications in light-duty liquid cleaning products were evaluated in vitro using a human skin analogue (ATS SKIN(2) Model ZK1100) for predicting cytotoxicity (MTT reduction) and inflammation [prostaglandin E(2) (PGE(2)) release]. Two of the 11 raw materials, both in the same compound family, were selected to be individually combined with each of the other nine in a 90:10 (raw:selected raw) mixture. Selection criteria were based on desired performance characteristics and low irritation potential as suggested from the individual surfactant assay data. To determine whether irritation potential was mitigated, MTT and PGE(2) scores were again determined for each of the 18 combinations with the resulting data being compared with the untreated raw material data. A plot of the data indicated that one of two selected materials may have an 'anti-irritant' effect. For raw materials with intrinsic MTT scores of less than 50 mug/ml and with the original data corrected for possible dilution effects, a statistical comparison between individual raw materials and the two sets of combinations was done using a one-sample analysis. Both cytotoxicity (MTT) and inflammation (PGE(2)) were significantly decreased by the milder of the two selected raw materials. By factoring the data into future new product decisions, this methodology has become a useful and practical tool for Amway product development.

  20. Herbal Supplement in a Buffer for Dry Eye Syndrome Treatment.

    PubMed

    Chen, Hung-Chang; Chen, Zhi-Yu; Wang, Tsung-Jen; Drew, Victor J; Tseng, Ching-Li; Fang, Hsu-Wei; Lin, Feng-Huei

    2017-08-03

    Dry eye syndrome (DES) is one of the most common types of ocular diseases. There is a major need to treat DES in a simple yet efficient way. Artificial tears (AT) are the most commonly used agents for treating DES, but are not very effective. Herbal extractions of ferulic acid (FA), an anti-oxidant agent, and kaempferol (KM), an anti-inflammatory reagent, were added to buffer solution (BS) to replace ATs for DES treatment. The cytotoxicity and anti-inflammatory effects were examined in vitro by co-culture with human corneal epithelial cells (HCECs) to obtain the optimal concentration of KM and FA for treating HCECs. Physical properties of BS, such as pH value, osmolality, and refractive index were also examined. Then, rabbits with DES were used for therapeutic evaluation. Tear production, corneal damage, and ocular irritation in rabbits' eyes were examined. The non-toxic concentrations of KM and FA for HCEC cultivation over 3 days were 1 µM and 100 µM, respectively. Live/dead stain results also show non-toxicity of KM and FA for treating HCECs. Lipopolysaccharide-stimulated HCECs in inflammatory conditions treated with 100 µM FA and 1 µM KM (FA100/KM1) showed lower IL-1B , IL-6 , IL-8 , and TNFα expression when examined by real-time PCR. The BS with FA100/KM1 had neutral pH, and a similar osmolality and refractive index to human tears. Topical delivery of BS + FA100/KM1 showed no irritation to rabbit eyes. The corneal thickness in the BS + FA100/KM1 treated group was comparable to normal eyes. Results of DES rabbits treated with BS + FA100/KM1 showed less corneal epithelial damage and higher tear volume than the normal group. In conclusion, we showed that the combination of FA (100 µM) and KM (1 µM) towards treating inflamed HCECs had an anti-inflammatory effect, and it is effective in treating DES rabbits when BS is added in combination with these two herbal supplements and used as a topical eye drop.

  1. Development of ocular drug delivery systems using molecularly imprinted soft contact lenses.

    PubMed

    Tashakori-Sabzevar, Faezeh; Mohajeri, Seyed Ahmad

    2015-05-01

    Recently, significant advances have been made in order to optimize drug delivery to ocular tissues. The main problems in ocular drug delivery are poor bioavailability and uncontrollable drug delivery of conventional ophthalmic preparations (e.g. eye drops). Hydrogels have been investigated since 1965 as new ocular drug delivery systems. Increase of hydrogel loading capacity, optimization of drug residence time on the ocular surface and biocompatibility with the eye tissue has been the main focus of previous studies. Molecular imprinting technology provided the opportunity to fulfill the above-mentioned objectives. Molecularly imprinted soft contact lenses (SCLs) have high potentials as novel drug delivery systems for the treatment of eye disorders. This technique is used for the preparation of polymers with specific binding sites for a template molecule. Previous studies indicated that molecular imprinting technology could be successfully applied for the preparation of SCLs as ocular drug delivery systems. Previous research, particularly in vivo studies, demonstrated that molecular imprinting is a versatile and effective method in optimizing the drug release behavior and enhancing the loading capacity of SCLs as new ocular drug delivery systems. This review highlights various potentials of molecularly imprinted contact lenses in enhancing the drug-loading capacity and controlling the drug release, compared to other ocular drug delivery systems. We have also studied the effects of contributing factors such as the type of comonomer, template/functional monomer molar ratio, crosslinker concentration in drug-loading capacity, and the release properties of molecularly imprinted hydrogels.

  2. Lenalidomide, an anti-tumor drug, regulates retinal endothelial cell function: Implication for treating ocular neovascular disorder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, Ling-Feng; Yao, Jin; Wang, Xiao-Qun

    Ocular angiogenesis is an important pathologic character of several ocular diseases, such as retinopathy of prematurity, diabetic retinopathy and age-related macular degeneration (AMD). Inhibition of ocular angiogenesis has great therapeutic value for treating these dieses. Here we show that lenalidomide, an anti-tumor drug, has great anti-angiogenic potential in ocular diseases. Lenalidomide inhibits retinal endothelial cell viability in normal and pathological condition, and inhibits VEGF-induced endothelial cell migration and tube formation in vitro. Moreover, lenalidomide inhibits ocular angiogenesis in vivo through the reduction of angiogenesis- and inflammation-related protein expression. Collectively, lenalidomide is a promising drug for treating ocular angiogenesis through its anti-proliferative andmore » anti-inflammatory property. - Highlights: • Lenalidomide inhibits retinal endothelial cell viability in vitro. • Lenalidomide inhibits retinal endothelial cell migration and tube formation. • Lenalidomide inhibits pathological ocular angiogenesis in vivo. • Lenalidomide inhibits angiogenesis- and inflammation-related protein expression.« less

  3. The role of microbial flora on the ocular surface.

    PubMed

    Miller, Darlene; Iovieno, Alfonso

    2009-10-01

    Presence and interplay of microbial flora at the ocular surface reveal dynamic and evolving interactions with implications for both ocular surface health and disease. Data in this area are scarce or non-existent. The purpose of this review is to provide a snapshot of new and emerging developments in this area over the last 12 months. Recent findings signal potential roles for ocular surface microbial flora in both the preservation and extension of ocular surface health and in the initiation of new or escalation of common surface disorders. Contributions range from priming surface epithelial immune cells to regulating mucin composition and production. Other findings explore the emergent role of ocular microbial flora cross talk with pattern recognition receptors to protect and strengthen local and adaptive mucosal immunity while preserving vision. Deciphering the functional role of microbial communities at the ocular surface could bring new insights into and clarify the epidemiology and pathology of ocular surface dynamics in health and disease.

  4. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  5. Infection and Replication of Influenza Virus at the Ocular Surface.

    PubMed

    Creager, Hannah M; Kumar, Amrita; Zeng, Hui; Maines, Taronna R; Tumpey, Terrence M; Belser, Jessica A

    2018-04-01

    Although influenza viruses typically cause respiratory tract disease, some viruses, particularly those with an H7 hemagglutinin, have been isolated from the eyes of conjunctivitis cases. Previous work has shown that isolates of multiple subtypes from both ocular and respiratory infections are capable of replication in human ex vivo ocular tissues and corneal or conjunctival cell monolayers, leaving the determinants of ocular tropism unclear. Here, we evaluated the effect of several variables on tropism for ocular cells cultured in vitro and examined the potential effect of the tear film on viral infectivity. All viruses tested were able to replicate in primary human corneal epithelial cell monolayers subjected to aerosol inoculation. The temperature at which cells were cultured postinoculation minimally affected infectivity. Replication efficiency, in contrast, was reduced at 33°C relative to that at 37°C, and this effect was slightly greater for the conjunctivitis isolates than for the respiratory ones. With the exception of a seasonal H3N2 virus, the subset of viruses studied in multilayer corneal tissue constructs also replicated productively after either aerosol or liquid inoculation. Human tears significantly inhibited the hemagglutination of both ocular and nonocular isolates, but the effect on viral infectivity was more variable, with tears reducing the infectivity of nonocular isolates more than ocular isolates. These data suggest that most influenza viruses may be capable of establishing infection if they reach the surface of ocular cells but that this is more likely for ocular-tropic viruses, as they are better able to maintain their infectivity during passage through the tear film. IMPORTANCE The potential spread of zoonotic influenza viruses to humans represents an important threat to public health. Unfortunately, despite the importance of cellular and tissue tropism to pathogenesis, determinants of influenza virus tropism have yet to be fully elucidated. Here, we sought to identify factors that limit the ability of most influenza viruses to cause ocular infection. Although ocular symptoms in humans caused by avian influenza viruses tend to be relatively mild, these infections are concerning due to the potential of the ocular surface to serve as a portal of entry for viruses that go on to establish respiratory infections. Furthermore, a better understanding of the factors that influence infection and replication in this noncanonical site may point toward novel determinants of tropism in the respiratory tract. This is a work of the U.S. Government and is not subject to copyright protection in the United States. Foreign copyrights may apply.

  6. Risk of Adverse Health and Performance Effects of Celestial Dust Exposure

    NASA Technical Reports Server (NTRS)

    Scully, Robert R.; Meyers, Valerie E.

    2015-01-01

    Crew members can be directly exposed to celestial dust in several ways. After crew members perform extravehicular activities (EVAs), they may introduce into the habitat dust that will have collected on spacesuits and boots. Cleaning of the suits between EVAs and changing of the Environmental Control Life Support System filters are other operations that could result in direct exposure to celestial dusts. In addition, if the spacesuits used in exploration missions abrade the skin, as current EVA suits have, then contact with these wounds would provide a source of exposure. Further, if celestial dusts gain access to a suit's interior, as was the case during the Apollo missions, the dust could serve as an additional source of abrasions or enhance suit-induced injuries. When a crew leaves the surface of a celestial body and returns to microgravity, the dust that is introduced into the return vehicle will "float," thus increasing the opportunity for ocular and respiratory injury. Because the features of the respirable fraction of lunar dusts indicate they could be toxic to humans, NASA conducted several studies utilizing lunar dust simulants and authentic lunar dust to determine the unique properties of lunar dust that affect physiology, assess the dermal and ocular irritancy of the dust, and establish a permissible exposure limit for episodic exposure to airborne lunar dust during missions that would involve no more than 6 months stay on the lunar surface. Studies, with authentic lunar soils from both highland (Apollo 16) and mare (Apollo17) regions demonstrated that the lunar soil is highly abrasive to a high fidelity model of human skin. Studies of lunar dust returned during the Apollo 14 mission from an area of the moon in which the soils were comprised of mineral constituents from both major geological regions (highlands and mares regions) demonstrated only minimal ocular irritancy, and pulmonary toxicity that was less than the highly toxic terrestrial crystalline silica (Permissible Exposure Limit [PEL] 0.05 mg/m3) but more toxic than the nuisance dust titanium dioxide (TiO2 [PEL 5.0 mg/m3]). A PEL for episodic exposure to airborne lunar dust during a six-month stay on the lunar surface was established, in consultation with an independent, extramural panel of expert pulmonary toxicologists, at 0.3 mg/m3. The PEL provided for lunar dust is limited to the conditions and exposure specified therefore additional research remains to be accomplished with lunar dust to further address the issues of activation, address other areas of more unique lunar geology (Glotch et al., 2010; Greenhagen et al., 2010), examine potential toxicological effects of inhaled or ingested dust upon other organ systems, such cardiovascular, nervous systems, and examine effects of acute exposure to massive doses of dust such as may occur during off-nominal situations. Work to support the establishment of PELs for Martian dust and dusts of asteroids remains to be accomplished. The literature that describes health effects of exposure to toxic terrestrial dusts provides substantial basis for concern that prolonged exposure to respirable celestial dust could be detrimental to human health. Celestial bodies where a substantial portion of the dust is in the respirable range or where the dusts have large reactive surface areas or contain transition metals or volatile organics, represent greater risks of adverse effects from exposure to the dust. It is possible that in addition to adverse effects to the respiratory system, inhalation and ingestion of celestial dusts could pose risks to other systems

  7. Corneal toxicity induced by vesicating agents and effective treatment options

    PubMed Central

    Goswami, Dinesh G.; Tewari-Singh, Neera; Agarwal, Rajesh

    2016-01-01

    The vesicating agents sulfur mustard (SM) and lewisite (LEW) are potent chemical warfare agents that primarily cause damage to the ocular, skin, and respiratory systems. However, ocular tissue is the most sensitive organ, and vesicant exposure results in a biphasic injury response, including photophobia, corneal lesions, corneal edema, ulceration, and neovascularization, and may cause loss of vision. There are several reports on ocular injury from exposure to SM, which has been frequently used in warfare. However, there are very few reports on ocular injury by LEW, which indicate that injury symptoms appear instantly after exposure and faster than SM. In spite of extensive research efforts, effective therapies for vesicant-induced ocular injuries, mainly to the most affected corneal tissue, are not available. Hence, we have established primary human corneal epithelial (HCE) cells and rabbit corneal organ culture models with the SM analog nitrogen mustard (NM), which have helped to test the efficacy of potential therapeutic agents. These agents will then be further evaluated against in vivo SM- and LEW-induced corneal injury models, which will assist in the development of potential broad-spectrum therapies against vesicant-induced ocular injuries. PMID:27327041

  8. Ocular diseases: immunological and molecular mechanisms

    PubMed Central

    Song, Jing; Huang, Yi-Fei; Zhang, Wen-Jing; Chen, Xiao-Fei; Guo, Yu-Mian

    2016-01-01

    Many factors, such as environmental, microbial and endogenous stress, antigen localization, can trigger the immunological events that affect the ending of the diverse spectrum of ocular disorders. Significant advances in understanding of immunological and molecular mechanisms have been researched to improve the diagnosis and therapy for patients with ocular inflammatory diseases. Some kinds of ocular diseases are inadequately responsive to current medications; therefore, immunotherapy may be a potential choice as an alternative or adjunctive treatment, even in the prophylactic setting. This article first provides an overview of the immunological and molecular mechanisms concerning several typical and common ocular diseases; second, the functions of immunological roles in some of systemic autoimmunity will be discussed; third, we will provide a summary of the mechanisms that dictate immune cell trafficking to ocular local microenvironment in response to inflammation. PMID:27275439

  9. Ocular diseases: immunological and molecular mechanisms.

    PubMed

    Song, Jing; Huang, Yi-Fei; Zhang, Wen-Jing; Chen, Xiao-Fei; Guo, Yu-Mian

    2016-01-01

    Many factors, such as environmental, microbial and endogenous stress, antigen localization, can trigger the immunological events that affect the ending of the diverse spectrum of ocular disorders. Significant advances in understanding of immunological and molecular mechanisms have been researched to improve the diagnosis and therapy for patients with ocular inflammatory diseases. Some kinds of ocular diseases are inadequately responsive to current medications; therefore, immunotherapy may be a potential choice as an alternative or adjunctive treatment, even in the prophylactic setting. This article first provides an overview of the immunological and molecular mechanisms concerning several typical and common ocular diseases; second, the functions of immunological roles in some of systemic autoimmunity will be discussed; third, we will provide a summary of the mechanisms that dictate immune cell trafficking to ocular local microenvironment in response to inflammation.

  10. Vestibular evoked myogenic potentials (VEMPs) in central neurological disorders.

    PubMed

    Venhovens, J; Meulstee, J; Verhagen, W I M

    2016-01-01

    Several types of acoustic stimulation (i.e. tone bursts or clicks), bone-conducted vibration, forehead taps, and galvanic stimulation elicit myogenic potentials. These can be recorded in cervical and ocular muscles, the so called vestibular evoked myogenic potentials (VEMPs). The cervical VEMP (cVEMP) resembles the vestibulo-collic reflex and the responses can be recorded from the ipsilateral sternocleidomastoid muscle. The ocular VEMP resembles the vestibulo-ocular reflex and can be recorded from extra-ocular muscles by a surface electrode beneath the contralateral infraorbital margin. Initially, the literature concerning VEMPs was limited to peripheral vestibular disorders, however, the field of VEMP testing is rapidly expanding, with an increasing focus on central neurological disorders. The current literature concerning VEMP abnormalities in central neurological disorders is critically reviewed, especially regarding the methodological aspects in relation to quality as well as the clinical interpretation of the VEMP results. Suggestions for further research are proposed as well as some clinically useful indications. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Homoisoflavonoids as potential antiangiogenic agents for retinal neovascularization.

    PubMed

    Amin, Sk Abdul; Adhikari, Nilanjan; Gayen, Shovanlal; Jha, Tarun

    2017-11-01

    A number of people worldwide have been suffering from ocular neovascularization that may be treated by a variety of drugs but these may possess adverse effects. Therefore, small antiangiogenic molecules with higher potency and lower toxic effects are intended. However, homoisoflavonoids of natural origin show the potential antiangiogenic effect in ocular neovascularization. These homoisoflavonoids are judged quantitatively in terms of statistical validation through multi-chemometric modeling approaches for the betterment and refinement of their structures required for higher antiangiogenic activity targeted to ocular neovascularization. These approaches may be utilized to design better antiangiogenic homoisoflavonoids. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. American college of gastroenterology monograph on the management of irritable bowel syndrome.

    PubMed

    Camilleri, Michael

    2015-04-01

    This editorial reviews a recently published guideline on management of irritable bowel syndrome. The guideline illustrates problems arising from the quality of clinical trials used in systematic reviews and the potential impact of the inherent weaknesses of those trials on rating the strength of evidence and the resulting recommendations.

  13. The planarian TRPA1 homolog mediates extraocular behavioral responses to near-ultraviolet light.

    PubMed

    Birkholz, Taylor R; Beane, Wendy S

    2017-07-15

    Although light is most commonly thought of as a visual cue, many animals possess mechanisms to detect light outside of the eye for various functions, including predator avoidance, circadian rhythms, phototaxis and migration. Here we confirm that planarians (like Caenorhabditis elegans , leeches and Drosophila larvae) are capable of detecting and responding to light using extraocular photoreception. We found that, when either eyeless or decapitated worms were exposed to near-ultraviolet (near-UV) light, intense wild-type photophobic behaviors were still observed. Our data also revealed that behavioral responses to green wavelengths were mediated by ocular mechanisms, whereas near-UV responses were driven by extraocular mechanisms. As part of a candidate screen to uncover the genetic basis of extraocular photoreception in the planarian species Schmidtea mediterranea , we identified a potential role for a homolog of the transient receptor potential channel A1 ( TRPA1 ) in mediating behavioral responses to extraocular light cues. RNA interference (RNAi) to Smed-TrpA resulted in worms that lacked extraocular photophobic responses to near-UV light, a mechanism previously only identified in Drosophila These data show that the planarian TRPA1 homolog is required for planarian extraocular-light avoidance and may represent a potential ancestral function of this gene. TRPA1 is an evolutionarily conserved detector of temperature and chemical irritants, including reactive oxygen species that are byproducts of UV-light exposure. Our results suggest that planarians possess extraocular photoreception and display an unconventional TRPA1-mediated photophobic response to near-UV light. © 2017. Published by The Company of Biologists Ltd.

  14. Adverse reactions to cosmetics and methods of testing.

    PubMed

    Nigam, P K

    2009-01-01

    Untoward reactions to cosmetics, toiletries, and topical applications are the commonest single reason for hospital referrals with allergic contact dermatitis. In most cases, these are only mild or transient and most reactions being irritant rather than allergic in nature. Various adverse effects may occur in the form of acute toxicity, percutaneous absorption, skin irritation, eye irritation, skin sensitization and photosensitization, subchronic toxicity, mutagenicity/genotoxicity, and phototoxicity/photoirritation. The safety assessment of a cosmetic product clearly depends upon how it is used, since it determines the amount of substance which may be ingested, inhaled, or absorbed through the skin or mucous membranes. Concentration of ingredients used in the different products is also important. Various test procedures include in vivo animal models and in vitro models, such as open or closed patch test, in vivo skin irritation test, skin corrosivity potential tests (rat skin transcutaneous electrical resistance test, Episkin test), eye irritation tests (in vivo eye irritancy test and Draize eye irritancy test), mutagenicity/genotoxicity tests (in vitro bacterial reverse mutation test and in vitro mammalian cell chromosome aberration test), and phototoxicity/photoirritation test (3T3 neutral red uptake phototoxicity test). Finished cosmetic products are usually tested in small populations to confirm the skin and mucous membrane compatibility, and to assess their cosmetic acceptability.

  15. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    PubMed

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. A new, female-specific irritability rating scale

    PubMed Central

    Born, Leslie; Koren, Gideon; Lin, Elizabeth; Steiner, Meir

    2008-01-01

    Objective Irritability is a prominent symptom in the spectrum of female-specific mood disorders, and in some women, irritability is serious enough to disrupt their lives and warrant treatment. The objective of this research was to develop a new, female-specific state measure of irritability. Methods We constructed self-rating and observer rating scales using items derived from spontaneous descriptions of irritability by women with mood disturbances related to the menstrual cycle, childbearing or menopause. Following a pretest, the scales were shortened to the core items of irritability (annoyance, anger, tension, hostility, sensitivity to noise and touch) and tested on a new cohort of patients. Results The 14-item Self-Rating Scale and the 5-item Observer Rating Scale showed evidence for internal consistency (Self-Rating: n = 36 patients, Cronbach's α = 0.9257, mean interitem correlation = 0.4690; Observer Rating: Cronbach's α = 0.7418, mean interitem correlation = 0.3616), Self-Rating test–retest reliability (n = 29 patients, rs = 0.704, p = 0.01) and interrater reliability (n = 20 patients; τb = 1.000, p = 0.001). Conclusion This new, female-specific scale for rating irritability has the potential to further the evaluation of this prominent symptom cluster and increase specificity in clinical assessments of emotional disturbances related to reproductive cyclicity in women. PMID:18592028

  17. Contact sensitizing potential of pyrogallol and 5-amino-o-cresol in female BALB/c Mice

    PubMed Central

    Guo, T.L.; Germolec, D.R.; Zhang, Ling X.; Auttachoat, W.; Smith, M.J.; White, K.L.

    2013-01-01

    Hair dye components such as pyrogallol and cresol have been shown previously to promote allergic reactions such as rashes, dermal inflammation, irritation and dermatitis. The objective of this study was to determine the contact sensitization potential of pyrogallol (PYR) and 5-amino-o-cresol (AOC) when applied dermally to female BALB/c mice. Measurement of the contact hypersensitivity response was initially accomplished using the local lymph node assay. For PYR, significant increases in the proliferation of lymph node cells were observed at concentrations of 0.5% (w/v) and higher. For AOC, borderline increases, albeit significant, in auricular lymph node cell proliferation were observed at 5% and 10%. Results from the irritancy assay suggested that PYR, but not AOC, was an irritant. To further delineate whether PYR was primarily an irritant or a contact sensitizer, the mouse ear swelling test (MEST) was conducted. A significant increase in mouse ear thickness was observed at 72 hr following challenge with 0.5% PYR in mice that had been sensitized with 5% PYR. In contrast, no effects were observed in the MEST in mice sensitized and challenged with the highest achievable concentration of AOC (10%). Additional studies examining lymph node subpopulations and CD86 (B7.2) expression by B cells further support the indication that PYR was a sensitizer in BALB/c mice. The results demonstrate that PYR is both a sensitizer and an irritant in female BALB/c mice. However, the contact sensitization potential of AOC is minimal in this strain of mouse. PMID:24172597

  18. Safety assessment of Salicylic Acid, Butyloctyl Salicylate, Calcium Salicylate, C12-15 Alkyl Salicylate, Capryloyl Salicylic Acid, Hexyldodecyl Salicylate, Isocetyl Salicylate, Isodecyl Salicylate, Magnesium Salicylate, MEA-Salicylate, Ethylhexyl Salicylate, Potassium Salicylate, Methyl Salicylate, Myristyl Salicylate, Sodium Salicylate, TEA-Salicylate, and Tridecyl Salicylate.

    PubMed

    2003-01-01

    Salicylic Acid is an aromatic acid used in cosmetic formulations as a denaturant, hair-conditioning agent, and skin-conditioning agent--miscellaneous in a wide range of cosmetic products at concentrations ranging from 0.0008% to 3%. The Calcium, Magnesium, and MEA salts are preservatives, and Potassium Salicylate is a cosmetic biocide and preservative, not currently in use. Sodium Salicylate is used as a denaturant and preservative (0.09% to 2%). The TEA salt of Salicylic Acid is used as an ultraviolet (UV) light absorber (0.0001% to 0.75%). Several Salicylic Acid esters are used as skin conditioning agents--miscellaneous (Capryloyl, 0.1% to 1%; C12-15 Alkyl, no current use; Isocetyl, 3% to 5%; Isodecyl, no current use; and Tridecyl, no current use). Butyloctyl Salicylate (0.5% to 5%) and Hexyldodecyl Salicylate (no current use) are hair-conditioning agents and skin-conditioning agents--miscellaneous. Ethylhexyl Salicylate (formerly known as Octyl Salicylate) is used as a fragrance ingredient, sunscreen agent, and UV light absorber (0.001% to 8%), and Methyl Salicylate is used as a denaturant and flavoring agent (0.0001% to 0.6%). Myristyl Salicylate has no reported function. Isodecyl Salicylate is used in three formulations, but no concentration of use information was reported. Salicylates are absorbed percutaneously. Around 10% of applied salicylates can remain in the skin. Salicylic Acid is reported to enhance percutaneous penetration of some agents (e.g., vitamin A), but not others (e.g., hydrocortisone). Little acute toxicity (LD(50) in rats; >2 g/kg) via a dermal exposure route is seen for Salicylic Acid, Methyl Salicylate, Tridecyl Salicylate, and Butyloctyl Salicylate. Short-term oral, inhalation, and parenteral exposures to salicylates sufficient to produce high blood concentrations are associated primarily with liver and kidney damage. Subchronic dermal exposures to undiluted Methyl Salicylate were associated with kidney damage. Chronic oral exposure to Methyl Salicylate produced bone lesions as a function of the level of exposure in 2-year rat studies; liver damage was seen in dogs exposed to 0.15 g/kg/day in one study; kidney and liver weight increases in another study at the same exposure; but no liver or kidney abnormalities in a study at 0.167 g/kg/day. Applications of Isodecyl, Tridecyl, and Butyloctyl Salicylate were not irritating to rabbit skin, whereas undiluted Ethylhexyl Salicylate produced minimal to mild irritation. Methyl Salicylate at a 1% concentration with a 70% ethanol vehicle were irritating, whereas a 6% concentration in polyethylene glycol produced little or no irritation. Isodecyl Salicylate, Methyl Salicylate, Ethylhexyl (Octyl) Salicylate, Tridecyl Salicylate, and Butyloctyl Salicylate were not ocular irritants. Although Salicylic Acid at a concentration of 20% in acetone was positive in the local lymph node assay, a concentration of 20% in acetone/olive oil was not. Methyl Salicylate was negative at concentrations up to 25% in this assay, independent of vehicle. Maximization tests of Methyl Salicylate, Ethylhexyl Salicylate, and Butyloctyl Salicylate produced no sensitization in guinea pigs. Neither Salicylic Acid nor Tridecyl Salicylate were photosensitizers. Salicylic Acid, produced when aspirin is rapidly hydrolyzed after absorption from the gut, was reported to be the causative agent in aspirin teratogenesis in animals. Dermal exposures to Methyl Salicylate, oral exposures to Salicylic Acid, Sodium Salicylate, and Methyl Salicylate, and parenteral exposures to Salicylic Acid, Sodium Salicylate, and Methyl Salicylate are all associated with reproductive and developmental toxicity as a function of blood levels reached as a result of exposure. An exposure assessment of a representative cosmetic product used on a daily basis estimated that the exposure from the cosmetic product would be only 20% of the level seen with ingestion of a "baby" aspirin (81 mg) on a daily basis. Studies of the genotoxic potential of Salicylic Acid, Sodium Salicylate, Isodecyl Salicylate, Methyl Salicylate, cosmetic product would be only 20% of the level seen with ingestion of a "baby" aspirin (81 mg) on a daily basis. Studies of the genotoxic potential of Salicylic Acid, Sodium Salicylate, Isodecyl Salicylate, Methyl Salicylate, Ethylhexyl (Octyl) Salicylate, Tridecyl Salicylate, and Butyloctyl Salicylate were generally negative. Methyl Salicylate, in a mouse skin-painting study, did not induce neoplasms. Likewise, Methyl Salicylate was negative in a mouse pulmonary tumor system. In clinical tests, Salicylic Acid (2%) produced minimal cumulative irritation and slight or no irritation(1.5%); TEA-Salicylate (8%) produced no irritation; Methyl Salicylate (>12%) produced pain and erythema, a 1% aerosol produced erythema, but an 8% solution was not irritating; Ethylhexyl Salicylate (4%) and undiluted Tridecyl Salicylate produced no irritation. In atopic patients, Methyl Salicylate caused irritation as a function of concentration (no irritation at concentrations of 15% or less). In normal skin, Salicylic Acid, Methyl Salicylate, and Ethylhexyl (Octyl) Salicylate are not sensitizers. Salicylic Acid is not a photosensitizer, nor is it phototoxic. Salicylic Acid and Ethylhexyl Salicylate are low-level photoprotective agents. Salicylic Acid is well-documented to have keratolytic action on normal human skin. Because of the possible use of these ingredients as exfoliating agents, a concern exists that repeated use may effectively increase exposure of the dermis and epidermis to UV radiation. It was concluded that the prudent course of action would be to advise the cosmetics industry that there is a risk of increased UV radiation damage with the use of any exfoliant, including Salicylic Acid and the listed salicylates, and that steps need to be taken to formulate cosmetic products with these ingredients as exfoliating agents so as not to increase sun sensitivity, or when increased sun sensitivity would be expected, to include directions for the daily use of sun protection. The available data were not sufficient to establish a limit on concentration of these ingredients, or to identify the minimum pH of formulations containing these ingredients, such that no skin irritation would occur, but it was recognized that it is possible to formulate cosmetic products in a way such that significant irritation would not be likely, and it was concluded that the cosmetics industry should formulate products containing these ingredients so as to be nonirritating. Although simultaneous use of several products containing Salicylic Acid could produce exposures greater than would be seen with use of baby aspirin (an exposure generally considered to not present a reproductive or developmental toxicity risk), it was not considered likely that consumers would simultaneously use multiple cosmetic products containing Salicylic Acid. Based on the available information, the Cosmetic Ingredient Review Expert Panel reached the conclusion that these ingredients are safe as used when formulated to avoid skin irritation and when formulated to avoid increasing the skin's sun sensitivity, or, when increased sun sensitivity would be expected, directions for use include the daily use of sun protection.

  19. Ocular fishhook injuries.

    PubMed

    Ang, C S

    2001-06-01

    Ocular fishhook injuries are rare, yet potentially vision threatening as complications such as corneal scarring, retinal detachment and endophthalmitis may result. The surgical management of these cases is challenging due to the construction of barbed fishhooks.

  20. Differential gene expression responses distinguish contact and respiratory sensitizers and nonsensitizing irritants in the local lymph node assay.

    PubMed

    Adenuga, David; Woolhiser, Michael R; Gollapudi, B Bhaskar; Boverhof, Darrell R

    2012-04-01

    Genomic approaches have the potential to enhance the specificity and predictive accuracy of existing toxicology endpoints, including those for chemical sensitization. The present study was conducted to determine whether gene expression responses can distinguish contact sensitizers (1-chloro-2,4-dinitrobenzene [DNCB] and hexyl cinnamic aldehyde [HCA]), respiratory sensitizers (ortho-phthalaldehyde and trimellitic anhydride [TMA]), and nonsensitizing irritants (methyl salicylate [MS] and nonanoic acid [NA]) in the local lymph node assay (LLNA). Female Balb/c mice received doses of each chemical as per the standard LLNA dosing regimen on days 1, 2, and 3. Auricular lymph nodes were analyzed for tritiated thymidine ((3)HTdR) incorporation on day 6 and for gene expression responses on days 6 and 10. All chemicals induced dose-dependent increases in stimulation index, which correlated strongly with the number of differentially expressed genes. A majority of genes modulated by the irritants were similarly altered by the sensitizers, consistent with the irritating effects of the sensitizers. However, a select number of responses involved with immune-specific functions, such as dendritic cell activation, were unique to the sensitizers and may offer the ability to distinguish sensitizers from irritants. Genes for the mast cell proteases 1 and 8, Lgals7, Tim2, Aicda, Il4, and Akr1c18 were more strongly regulated by respiratory sensitizers compared with contact sensitizers and may represent potential biomarkers for discriminating between contact and respiratory sensitizers. Collectively, these data suggest that gene expression responses may serve as useful biomarkers to distinguish between respiratory and contact sensitizers and nonsensitizing irritants in the LLNA.

  1. Evaluation of Beryllium, Total Chromium and Nickel in the Surface Contaminant Layer Available for Dermal Exposure After Abrasive Blasting in a Shipyard

    DTIC Science & Technology

    2013-04-24

    established to minimize the potential of dermal irritation and dermatitis (6). Chromium exposure can lead to allergic contact dermatitis , irritant... dermatitis with skin contact . (5; 15; 25; 33; 47). Nickel is potentially the most common contact allergen among the general population. Some studies...thresholds - a review focusing on occluded nickel exposure. Contact Dermatitis 52:57-64 21. Fogh CL, Andersson KG. 2000. Modelling of skin exposure

  2. Acute Dermal Irritation Study and Salmonella-Escherichia coli/Microsome Plate Incorporation Assay of Hydroprocessed Esters and Fatty Acids (HEFA) Bio-Based Jet Fuels

    DTIC Science & Technology

    2013-01-01

    of the Safety of Chemicals in Foods , Drugs and Cosmetics – Dermal Toxicity. Association of Food and Drug Officials of the United States, Topeka, KS...Air Force is developing alternative fuels to decrease dependence on foreign oil. All new fuels are potentially hazardous to Air Force personnel and...oil. All new fuels are potentially hazardous to Air Force personnel and require toxicity evaluation. The objective of the dermal irritation study

  3. Front to back ocular injury from a vaping-related explosion.

    PubMed

    Khairudin, Muhammad Najmi; Mohd Zahidin, Aida Zairani; Bastion, Mae-Lynn Catherine

    2016-04-05

    We describe a case of extensive ocular injury secondary to an electronic cigarette (e-cigarette)-related explosion. The explosion was the result of modifications made to a heating element of the e-cigarette device by a non-professional. Extensive ocular injuries that result from an explosion of an e-cigarette device can potentially cause significant and permanent visual impairment. 2016 BMJ Publishing Group Ltd.

  4. Post-traumatic pseudomyopia.

    PubMed

    London, Richard; Wick, Bruce; Kirschen, David

    2003-02-01

    Many clinicians have noted that patients demonstrate a myopic refractive change following Traumatic Brain Injury (TBI). This apparent myopic shift disappears with cycloplegia, yet stubbornly reappears as soon as the pharmaceutical effect wears off. We propose that this shift is secondary to an irritative lesion that affects the parasympathetic innervation, resulting in ciliary body contracture. The dilemma for the clinician is whether to provide the immediate relief of clear distance vision by prescribing additional minus lenses, or to work toward attempting to re-establish the baseline refractive error. The natural history of post-traumatic pseudomyopia in our experience involves one of the following three courses: (1) a transient condition that will occasionally resolve; (2) the typical case, a recalcitrant condition that will resolve under cycloplegic intervention, but immediately return as the cycloplegic wears off; or (3) a less-common subgroup of patients who continue to show an increase in myopia over time. Our description of these cases demonstrates management strategies (including atropinization) to relax accommodative spasm, traditional vision therapy techniques aimed at loosening the accommodative system, and refractive corrections. Pseudomyopia is one of many ocular and behavioral sequelae following TBI. By understanding the natural course and potential management options for post-traumatic pseudomyopia, the clinician will be better prepared to deal with these challenging cases. Flexibility is required, since options that work with one patient may prove ineffective with another. Counseling the patient as to potential outcomes given the natural history of this condition helps establish more-realistic expectations by the patients being treated.

  5. Safety Study of an Antimicrobial Peptide Lactocin 160, Produced by the Vaginal Lactobacillus rhamnosus

    PubMed Central

    Dover, Sara E.; Aroutcheva, Alla A.; Faro, S.; Chikindas, Michael L.

    2007-01-01

    Objective. To evaluate the safety of the antimicrobial peptide, lactocin 160. Methods. Lactocin 160, a product of vaginal probiotic Lactobacillus rhamnosus 160 was evaluated for toxicity and irritation. An in vitro human organotypic vaginal-ectocervical tissue model (EpiVaginal) was employed for the safety testing by determining the exposure time to reduce tissue viability to 50% (ET-50). Hemolytic activity of lactocin160 was tested using 8% of human erythrocyte suspension. Susceptibility of lactobacilli to lactocin160 was also studied. Rabbit vaginal irritation (RVI) model was used for an in vivo safety evaluation. Results. The ET-50 value was 17.5 hours for lactocin 160 (4.9 hours for nonoxynol 9, N9). Hemolytic activity of lactocin 160 was 8.2% (N9 caused total hemolysis). Lactobacilli resisted to high concentrations of peptide preparation. The RVI model revealed slight vaginal irritation. An average irritation index grade was evaluated as “none.” Conclusions. Lactocin 160 showed minimal irritation and has a good potential for intravaginal application. PMID:18273406

  6. In vitro assessment of eye irritancy using the Reconstructed Human Corneal Epithelial SkinEthic HCE model: application to 435 substances from consumer products industry.

    PubMed

    Cotovio, José; Grandidier, Marie-Hélène; Lelièvre, Damien; Bremond, Christelle; Amsellem, Carolle; Maloug, Saber; Ovigne, Jean-Marc; Loisel-Joubert, Sophie; Lee, Aline Van Der; Minondo, Anne-Marie; Capallere, Christophe; Bertino, Béatrice; Alépée, Nathalie; Tinois-Tessonneaud, Estelle; de Fraissinette, Anne De Brugerolle; Meunier, Jean-Roch; Leclaire, Jacques

    2010-03-01

    The 7th amendment of the EU Cosmetics Directive led to the ban of eye irritation testing for cosmetic ingredients in animals, effective from March 11th 2009. Over the last 20years, many efforts have been made to find reliable and relevant alternative methods. The SkinEthic HCE model was used to evaluate the in vitro eye irritancy potential of substances from a cosmetic industry portfolio. An optimized protocol based on a specific 1-h treatment and a 16-h post-treatment incubation period was first assessed on a set of 102 substances. The prediction model (PM) based on a 50% viability cut-off, allowed to draw up two classes (Irritants and Non-Irritants), with good associated sensitivity (86.2%) and specificity (83.5%). To check the robustness of the method, the evaluated set was expanded up to 435 substances. Final performances maintained a high level and were characterized by an overall accuracy value > 82% when using EU or GHS classification rules. Results showed that the SkinEthic HCE test method is a promising in vitro tool for the prediction of eye irritancy. Optimization datasets were shared with the COLIPA Eye Irritation Project Team and ECVAM experts, and reviewed as part of an ongoing progression to enter an ECVAM prospective validation study for eye irritation. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  7. Switching from a preserved to a preservative-free prostaglandin preparation in topical glaucoma medication.

    PubMed

    Uusitalo, Hannu; Chen, Enping; Pfeiffer, Norbert; Brignole-Baudouin, Françoise; Kaarniranta, Kai; Leino, Markku; Puska, Päivi; Palmgren, Elina; Hamacher, Thomas; Hofmann, Günter; Petzold, Gernot; Richter, Ulrich; Riedel, Tobias; Winter, Martin; Ropo, Auli

    2010-05-01

    The purpose of this study was to investigate the tolerability and intraocular pressure (IOP) reducing effect of the first preservative-free prostaglandin tafluprost (Taflotan) in patients exhibiting ocular surface side-effects during latanoprost (Xalatan) treatment. A total of 158 patients were enrolled in this open-label multicentre study. Eligible patients had to have at least two ocular symptoms, or one sign and one symptom, during treatment with latanoprost. At baseline, the patients were directly switched from latanoprost to preservative-free tafluprost for 12 weeks. The patients were queried for ocular symptoms, and ocular signs were assessed by using tear break-up time, Schirmer's test, fluorescein staining and evaluation of conjunctival hyperaemia and blepharitis. In addition, HLA-DR and MUC5AC in conjunctival impression cytology specimens were analyzed, and a drop discomfort/quality of life (QoL) questionnaire was employed. IOP was measured at all visits. Preservative-free tafluprost maintained IOP at the same level after 12- weeks treatment (16.4 +/- 2.7 mmHg) as latanoprost at baseline (16.8 +/- 2.5 mmHg). During treatment with preservative-free tafluprost, the number of patients having irritation/burning/stinging (56.3%), itching (46.8%), foreign body sensation (49.4%), tearing (55.1%) and dry eye sensation (64.6%) decreased to 28.4%, 26.5%, 27.1%, 27.1% and 39.4% correspondingly. The number of the patients with abnormal fluorescein staining of cornea (81.6%) and conjunctiva (84.2%), blepharitis (60.1%), conjunctival hyperaemia (84.2%) and abnormal Schirmer's test (71.5%) was also reduced significantly to 40.6%, 43.2%, 40.6%, 60.0% and 59.4% correspondingly. The tear break-up time improved significantly from 4.5 +/- 2.5 seconds to 7.8 +/- 4.9 seconds. A reduction in the number of patients with abnormal conjunctival cells based on HLA-DR and MUC5AC was also detected. Preservative-free tafluprost maintained IOP at the same level as latanoprost, but was better tolerated in patients having signs or symptoms while on preserved latanoprost. Preservative-free tafluprost treatment resulted in improved QoL, increased patient satisfaction and drop comfort.

  8. Multicenter, Randomized, Controlled Study Comparing Tafluprost/Timolol Fixed Combination with Latanoprost/Timolol Fixed Combination in Primary Open-Angle Glaucoma and Ocular Hypertension.

    PubMed

    Suzuki, Katsuyoshi; Otsuka, Naomi; Hizaki, Hiroko; Hashimoto, Masayo; Kuwayama, Yasuaki

    2018-06-05

    This was the first exploratory randomized controlled study to compare the efficacy and safety of a preserved tafluprost/timolol fixed combination (TAF/TIM) with a preserved latanoprost/timolol fixed combination (LAT/TIM). This prospective, randomized, open-label study was conducted in Japanese patients with primary open-angle glaucoma, including normal-tension glaucoma or ocular hypertension. Following a 4-week LAT/TIM run-in period, eligible patients entered a 12-week treatment period, during which they received either LAT/TIM or TAF/TIM. The efficacy endpoint was the change in intraocular pressure (IOP) from baseline to week 12 and the safety endpoints included the changes from baseline to week 12 in superficial punctate keratopathy (SPK) score, tear breakup time (TBUT), and hyperemia score, as well as adverse events (AEs). At week 6, ocular symptoms were evaluated using a questionnaire. In total, 131 patients provided informed consent. Of these, 115 completed the run-in period and were assigned to receive TAF/TIM (n = 60) or LAT/TIM (n = 55). At week 12, there were no significant differences between the TAF/TIM and LAT/TIM groups in the change from baseline in trough IOP and IOP at 4-6 h after instillation. There were no significant differences between the two groups in the change from baseline to week 12 in SPK score, TBUT, and hyperemia score. However, only in the TAF/TIM group, the total SPK score and the inferior cornea SPK score were significantly lower at week 12 compared with baseline. Eye irritation and eye pain were significantly decreased in the TAF/TIM group compared with the LAT/TIM group. Two treatment-related AEs were reported in the TAF/TIM group (3.3%) and none in the LAT/TIM group, while no serious AEs were reported in either group. TAF/TIM is as effective as LAT/TIM in terms of IOP-reducing effect, with fewer ocular symptoms. TAF/TIM was associated with a significant improvement in SPK scores. UMIN Clinical Trials Registry Identifier, UMIN000023862. Santen Pharmaceutical Co., Ltd., Osaka, Japan.

  9. An approach for development of alternative test methods based on mechanisms of skin irritation.

    PubMed

    Osborne, R; Perkins, M A

    1994-02-01

    Recent advances in techniques for culture of human skin cells have led to their potential for use as in vitro models for skin irritation testing to augment or replace existing rabbit skin patch tests. Our work is directed towards the development of cultured human skin cells, together with endpoints that can be linked to in vivo mechanisms of skin irritation, as in vitro models for prediction of human skin irritation, and for study of mechanisms of contact irritant dermatitis. Three types of commercial human skin cell cultures have been evaluated, epidermal keratinocytes and partially or fully cornified keratinocyte-dermal fibroblast co-cultures. Human epidermal keratinocyte cultures (Clonetics) were treated with product ingredients and formulations, and the extent of cell damage was assessed by incorporation of the vital dye neutral red. Cell damage correlated with human skin patch data for ingredient chemicals with the exception of acids and alkalis, but did not correlate with skin irritation to surfactant-containing product formulations. Cultures of human skin equivalents were evaluated as potential models for measurement of responses to test materials that could not be measured in the keratinocyte/neutral red assay. We developed a battery of in vitro endpoints to measure responses to prototype ingredients and formulations in human epidermal keratinocyte-dermal fibroblast co-cultures grown on a nylon mesh ('Skin2' from Advanced Tissue Sciences) or on a collagen gel ('Testskin' from Organogenesis). The endpoints measure cytotoxicity (neutral red and MTT vital dye staining, lactate dehydrogenase and N-acetyl glucosaminidase release, glucose utilization) and inflammatory mediator (prostaglandin E2) release. Initial experiments indicate a promising correlation between responses of the Skin2 model to prototype surfactants and in vivo human skin irritation. The responses of Testskin cultures to acids and alkalis help to prove the concept that a topical application model can measure responses to these materials. These results suggest that human skin cell models can provide useful systems for preclinical skin irritation assessments, as alternatives to rabbits, for at least certain classes of test substances.

  10. Animal models of ocular angiogenesis: from development to pathologies.

    PubMed

    Liu, Chi-Hsiu; Wang, Zhongxiao; Sun, Ye; Chen, Jing

    2017-11-01

    Pathological angiogenesis in the eye is an important feature in the pathophysiology of many vision-threatening diseases, including retinopathy of prematurity, diabetic retinopathy, and age-related macular degeneration, as well as corneal diseases with abnormal angiogenesis. Development of reproducible and reliable animal models of ocular angiogenesis has advanced our understanding of both the normal development and the pathobiology of ocular neovascularization. These models have also proven to be valuable experimental tools with which to easily evaluate potential antiangiogenic therapies beyond eye research. This review summarizes the current available animal models of ocular angiogenesis. Models of retinal and choroidal angiogenesis, including oxygen-induced retinopathy, laser-induced choroidal neovascularization, and transgenic mouse models with deficient or spontaneous retinal/choroidal neovascularization, as well as models with induced corneal angiogenesis, are widely used to investigate the molecular and cellular basis of angiogenic mechanisms. Theoretical concepts and experimental protocols of these models are outlined, as well as their advantages and potential limitations, which may help researchers choose the most suitable models for their investigative work.-Liu, C.-H., Wang, Z., Sun, Y., Chen, J. Animal models of ocular angiogenesis: from development to pathologies. © FASEB.

  11. Nanostructured lipid carriers as novel ophthalmic delivery system for mangiferin: improving in vivo ocular bioavailability.

    PubMed

    Liu, Rui; Liu, Zhidong; Zhang, Chengui; Zhang, Boli

    2012-10-01

    The aim of this study was to develop a novel nanostructured lipid carriers (NLCs) system to improve ocular bioavailability of mangiferin (MGN) for the potential treatment of cataract. The physicochemical properties of MGN-loaded NLC (MGN-NLC) formulation were characterized by particle size, polydispersity index, zeta potential, entrapment efficiency, drug loading, morphological property, and crystalline state. in vitro characteristics were investigated by drug release from NLC system, physical stability, and corneal permeation through excised rabbit cornea. Moreover, in vivo ocular tolerability was assessed by a modified Draize test and histological microscopy. Preocular retention capability was evaluated by slit-lamp observation. Pharmacokinetic study in the aqueous humor was performed by microdialysis technique. Transmission electron microscopy depicted spherical and uniform morphology. Differential scanning calorimetry and X-ray diffractometry displayed imperfect crystalline lattice. The optimized MGN-NLC formulation exhibited a sustained drug release with 3 months stability and 4.31-fold increase of in vitro corneal permeation. Furthermore, in vivo studies exhibited a high tolerance in the ocular tissues and prolonged drug retention capacity on the corneal surface. Finally, pharmacokinetic study suggested a 5.69-fold increase of ocular bioavailability compared with MGN solution (MGN-SOL). Therefore, NLC system is a promising approach for ocular delivery of MGN. Copyright © 2012 Wiley Periodicals, Inc.

  12. Microscopic and spectroscopic evaluation of novel PLGA-chitosan Nanoplexes as an ocular delivery system.

    PubMed

    Jain, Gaurav K; Pathan, Shadab A; Akhter, Sohail; Jayabalan, Nirmal; Talegaonkar, Sushma; Khar, Roop K; Ahmad, Farhan J

    2011-02-01

    The interaction of PLGA-chitosan Nanoplexes with ocular mucosa was investigated ex vivo and in vivo to assess their potential as ocular delivery system. Fluorescent Rhodamine Nanoplexes (Rd-Nanoplexes) were prepared by ionotropic gelation method. The size and morphology of Nanoplexes was investigated by TEM, SEM and PCS. The corneal retention, uptake and penetration of Nanoplexes were analyzed by spectrofluorimetry and confocal microscopy. Corneas from Rd-Nanoplexes-treated rabbits were evaluated for the in vivo uptake and ocular tolerance. The Nanoplexes prepared were round with a mean diameter of 115.6±17nm and the encapsulation efficiency of Rd was 59.4±2.5%. Data from ex vivo and in vivo studies showed that the amounts of Rd in the cornea were significantly higher for Nanoplexes than for a control Rd solution, these amounts being fairly constant for up to 24h. Confocal microscopy of the corneas revealed paracellular and transcellular uptake of the Nanoplexes. The uptake mechanism postulated was adsorptive-mediated endocytosis and opening of the tight junctions between epithelial cells. No alteration was microscopically observed after ocular surface exposure to Nanoplexes. Taken together, these data demonstrate that Nanoplexes are potentially useful as ocular drug carriers. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. The MOAHLFA index of irritant sodium lauryl sulfate reactions: first results of a multicentre study on routine sodium lauryl sulfate patch testing.

    PubMed

    Uter, Wolfgang; Geier, Johannes; Becker, Detlef; Brasch, Jochen; Löffler, Harald

    2004-01-01

    In a multicentre study of the German Contact Dermatitis Research Group, sodium lauryl sulfate (SLS) 0.25% and 0.5% aq. has been added to routine allergen patch tests to assess its properties as a convenient diagnostic indicator of individual susceptibility to irritation at the time of patch testing. Previous studies indicated that irritant SLS reactivity may be related to individual factors such as age and sex. As these factors are, in turn, among the important predictors of contact allergy to many allergens, e.g. summarized in the 'MOAHLFA index', the impact of the MOAHLFA factors on irritant SLS patch test reactivity, and thus a potential for confounding, was assessed in the 5971 participating patients. As a result of 2 logistic regression analyses with an irritant reaction to 0.25% and 0.5% SLS, respectively, as outcome, male sex was identified as a relatively weak but significant risk factor (OR 1.38), while age 40 years or older was an even weaker risk factor (OR 1.22 and 1.15, respectively). Upon detailed analysis, no clear age gradient could, however, be identified. 1-day exposure time almost halved the odds of an irritant SLS reaction. In conclusion, this type of SLS patch test can be regarded as robust, indicating individual irritability relatively independent from the individual factors analysed here.

  14. The Sub-Regional Functional Organization of Neocortical Irritative Epileptic Networks in Pediatric Epilepsy

    PubMed Central

    Janca, Radek; Krsek, Pavel; Jezdik, Petr; Cmejla, Roman; Tomasek, Martin; Komarek, Vladimir; Marusic, Petr; Jiruska, Premysl

    2018-01-01

    Between seizures, irritative network generates frequent brief synchronous activity, which manifests on the EEG as interictal epileptiform discharges (IEDs). Recent insights into the mechanism of IEDs at the microscopic level have demonstrated a high variance in the recruitment of neuronal populations generating IEDs and a high variability in the trajectories through which IEDs propagate across the brain. These phenomena represent one of the major constraints for precise characterization of network organization and for the utilization of IEDs during presurgical evaluations. We have developed a new approach to dissect human neocortical irritative networks and quantify their properties. We have demonstrated that irritative network has modular nature and it is composed of multiple independent sub-regions, each with specific IED propagation trajectories and differing in the extent of IED activity generated. The global activity of the irritative network is determined by long-term and circadian fluctuations in sub-region spatiotemporal properties. Also, the most active sub-region co-localizes with the seizure onset zone in 12/14 cases. This study demonstrates that principles of recruitment variability and propagation are conserved at the macroscopic level and that they determine irritative network properties in humans. Functional stratification of the irritative network increases the diagnostic yield of intracranial investigations with the potential to improve the outcomes of surgical treatment of neocortical epilepsy. PMID:29628910

  15. Interaction between intra-oral cinnamaldehyde and nicotine assessed by psychophysical and physiological responses.

    PubMed

    Jensen, Tanja K; Andersen, Michelle V; Nielsen, Kent A; Arendt-Nielsen, Lars; Boudreau, Shellie A

    2016-08-01

    Cinnamaldehyde and nicotine activate the transient receptor potential subtype A1 (TRPA1) channel, which may cause burning sensations. This study investigated whether cinnamaldehyde modulates nicotine-induced psychophysical and physiological responses in oral tissues. Healthy non-smokers (n = 22) received, in a randomized, double-blind, crossover design, three different gums containing 4 mg of nicotine, 20 mg of cinnamaldehyde, or a combination thereof. Assessments of orofacial temperature and blood flow, blood pressure, heart rate, taste experience, and intra-oral pain/irritation area and intensity were performed before, during, and after a 10-min chewing regime. Cinnamaldehyde increased the temperature of the tongue and blood flow of the lip, and was associated with pain/irritation, especially in the mouth. Nicotine increased the temperature of the tongue and blood flow of the cheek, and produced pain/irritation in the mouth and throat. The combination of cinnamaldehyde and nicotine did not overtly change the psychophysical or physiological responses. Interestingly, half of the subjects responded to cinnamaldehyde as an irritant, and these cinnamaldehyde responders reported greater nicotine-induced pain/irritation areas in the throat. Whether sensitivity to cinnamaldehyde can predict the response to nicotine-induced oral irritation remains to be determined. A better understanding of the sensory properties of nicotine in the oral mucosa has important therapeutic implications because pain and irritation represent compliance issues for nicotine replacement products. © 2016 Eur J Oral Sci.

  16. A Review of Ocular Graft-Versus-Host Disease.

    PubMed

    Munir, Saleha Z; Aylward, James

    2017-05-01

    : Graft-versus-host disease (GVHD) is a major complication that occurs following allogeneic hematopoietic stem cell transplantation, which is a potential curative therapy used in a variety of malignant or benign hematological diseases. Graft-versus-host disease primarily occurs in many organs, but most notably in the skin, lungs, gastrointestinal tract, liver, eyes, mucosa, and musculoskeletal system. Ocular manifestations of GVHD may precede other systemic GVHD findings, and it may be a poor prognosis for mortality. While all parts of the eye may be affected, ocular GVHD occurs primarily in the ocular surface. Dry eye disease or keratoconjunctivitis sicca is the most common presenting manifestation of chronic ocular GVHD. Dry eye disease in ocular GVHD is a multifactorial process, which involves destruction and fibrosis of lacrimal glands and conjunctiva, leading to tear film deficiency and instability. Depending on the severity of ocular involvement and response to treatment, ocular GVHD may cause decreased quality of life. Management of GVHD begins with prevention by understanding risk factors and by implementing prophylactic treatment after allogeneic hematopoietic stem cell transplantation. A multidisciplinary approach to the prevention and treatment of GVHD is important, and there are currently no preventive therapies available for ocular GVHD. Once diagnosed, ocular GVHD treatment strategies target ocular surface lubrication and support, tear film stabilization, inflammation reduction, and surgical intervention. The goal of this review is to define ocular GVHD and its categorical manifestations, as well as to describe the importance of comprehensive assessment, diagnosis, and ophthalmologic treatment and management of ocular GVHD with a multidisciplinary approach.

  17. In vivo eye surface residence determination by high-resolution scintigraphy of a novel ion-sensitive hydrogel based on gellan gum and kappa-carrageenan.

    PubMed

    Fernández-Ferreiro, Anxo; Silva-Rodríguez, Jesús; Otero-Espinar, Francisco Javier; González-Barcia, Miguel; Lamas, María Jesús; Ruibal, Alvaro; Luaces-Rodríguez, Andrea; Vieites-Prado, Alba; Lema, Isabel; Herranz, Michel; Gómez-Lado, Noemí; Blanco-Mendez, José; Gil-Martínez, María; Pardo, María; Moscoso, Alexis; Cortes, Julia; Sánchez-Martínez, María; Pardo-Montero, Juan; Aguiar, Pablo

    2017-05-01

    In last years, sensitive hydrogels have become a breakthrough in ophthalmic pharmaceutical technology aimed at developing new strategies to increase the residence time of active substances. In a previous paper, we qualitatively demonstrated the capacity of a new ion sensitive hydrogel to increase the residence time. Nevertheless, the clearance of the gel from the ocular surface was not quantifiable with the used methodology. The aim of the present work was to use a well-established approach based on scintigraphy to quantitatively estimate the residence time of the previously proposed hydrogel. The rat corneal residence time of a topic ophthalmic formulation containing gellan gum and kappa carragenan (0.82% w/v) labeled with 99m Tc-DTPA radiotracer was evaluated and compared with the residence of an aqueous solution. Ophthalmic safety studies such as eye irritation or passage through the cornea were also carried out. After 1.5h of contact, 77% of the hydrogel remained in the ocular surface, presenting kinetics of disappearance one-phase decay and a half time of 262min. We conclude that the novel ophthalmic hydrogel developed with kappa carrageenan and gellan gum remains for long periods of time on the corneal surface, presenting a drop that fits an exponential decay. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Reasons for family refusal of ocular tissue donation.

    PubMed

    Hermann, K C; Pagnussato, F; Franke, C A; de Oliveira, M L B

    2014-01-01

    Corneal donations do not fill the transplant demand. The waiting list had 5512 individuals in Brazil and 143 in Rio Grande do Sul in December 2012. The aim of this study was to identify the reasons for family refusal of ocular tissues donation. This retrospective study analyzed interview records for ocular tissue procurement performed in a general, public university hospital located in Southern Brazil between January 2008 and December 2012. It identified the reasons of family refusal for ocular tissue donation. A total of 1010 interviews for ocular tissues procurement were performed. From these, 513 (50.79%) refused donation with the following reasons: 60 (11.69%) family members were unaware of the desire of the potential donor, 153 (29.82%) of potential donors spoke against donation in life, 113 (22.02%) family members were undecided about the donation, 156 (30.40%) family members were against donation, 3 (0.58%) family members were unhappy with the service, 11 (2.14%) family members were afraid of body release delay, 6 (1.16%) families expressed religious convictions against donation, and 11 (2.14%) family members wanted to keep the body intact. There are many reasons for ocular tissues donation refusal, and the knowledge provides better strategies for family interviews. In this study, most of the reasons, around 90%, can be related to lack of information or communication about the subject. Greater awareness of the population about the subject can be a good way to increase ocular tissue procurement indexes. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Nanostructured lipid carriers for the topical delivery of tretinoin.

    PubMed

    Ghate, Vivek M; Lewis, Shaila A; Prabhu, Prabhakara; Dubey, Akhilesh; Patel, Nilkumar

    2016-11-01

    Cosmetic skin care products currently in the market demonstrate an increasing trend toward antiaging products. Selection of the right formulation approach is the key to successful consumer acceptance. Nanostructured lipid carriers (NLCs) for dermal application can render added benefits to the formulation. Tretinoin a derivative of vitamin A, is a retinoid with anti-aging and anti-acne potential. The present study was aimed at formulating NLCs of tretinoin for reducing the skin irritation potential, increasing the drug loading capacity and prolonging the duration of action. The NLCs were optimized using the response surface methodology based on the particle size. Preliminary study, suggested the use of stearic acid, oleic acid, Tween 80 and Span 60 as solid lipid, liquid lipid and surfactants respectively formed a stable dispersion. NLCs of tretinoin were prepared by hot melt microemulsion and hot melt probe sonication methods. The properties of the optimized NLCs such as morphology, size, Zeta potential, stability and in vitro drug release were investigated. Tretinoin loaded NLCs in carbopol gel showed a sustained release pattern with isopropyl alcohol as the receptor fluid compared to the marketed gel using Franz diffusion cells. Eight prepared gel formulations tested were found to follow the Higuchi model of drug release. Stability studies indicated that the formulations stored at refrigeration and room temperature showed no noticeable differences in the drug content and release profiles in vitro, after a period of 4 weeks. In vivo skin irritation test on male Wister rats indicated no irritation or erythema after application of the NLCs loaded gel repeated for a period of 7 days compared to the application of marketed tretinoin gel which showed irritation and slight erythema within 3 days. The results showed that the irritation potential of tretinoin was reduced, the drug loading was increased and the drug release was prolonged by the incorporation into the NLCs. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Interlaboratory study for the assessment of potential irritative properties of hygiene products on the hamster cheek pouch.

    PubMed

    Bourrinet, P; Conduzorgues, J P; Dutertre, H; Macabies, J; Masson, P; Maurin, J; Mercier, O

    1995-02-01

    An interlaboratory study was carried out to determine the feasibility and reliability of a method using the hamster cheek pouch as a model for assessing the potential irritative properties of substances intended to be applied to the lips or other mucous membranes. The test substances were applied once daily to both pouches for 14 consecutive days. Local and general tolerances were appraised throughout the study. At the end of the study, histologic examination of the pouches and the main organs was performed. Results of the feasibility study, conducted on various types of commercial products, indicated that this model is suitable for preparations of various consistence and composition. Results of the reliability study, carried out on gel-type preparations containing various concentrations of a known irritant, sodium lauryl sulfate, indicated that the method elicits a dose-dependent reaction for this compound. This hamster cheek pouch method was reproducible for the various parameters under consideration: local tolerance, general tolerance, histologic examination. For all products, results were in good agreement among the various laboratories participating in the study. The French regulatory authorities of the Fraud Repression Department have accepted it as an official method for the evaluation of the potential irritative properties of cosmetics and hygiene products intended to be applied to the lips or other mucous membranes.

  1. Celery-based topical repellents as a potential natural alternative for personal protection against mosquitoes.

    PubMed

    Tuetun, B; Choochote, W; Pongpaibul, Y; Junkum, A; Kanjanapothi, D; Chaithong, U; Jitpakdi, A; Riyong, D; Pitasawat, B

    2008-12-01

    Celery-based products were investigated for chemical composition, skin irritation, and mosquito repellency in comparison to commercial repellents and the standard chemical, N,N-diethyl-3-methylbenzamide (DEET), with a goal to develop a natural alternative to synthetic repellents for protection against mosquitoes. Chemical identification by gas chromatography coupled with mass spectrometry discovered that the major constituents of Apium graveolens hexane extract (AHE) were 3-n-butyl-tetrahydrophthalide (92.48%), followed by 5.10% beta-selinene and 0.68% gamma-selinene. Evaluation of skin irritation in 27 human volunteers revealed no irritant potential from 25% ethanolic AHE solution. Laboratory investigated repellent against female Aedes aegypti mosquitoes demonstrated that G10 formula, the best AHE-developed product, provided remarkable repellency with a median protection time of 4.5 h (4.5-5 h), which was greater than that of ethanolic DEET solution (25% DEET, 3.5 h) and comparable to that of the best commercial repellent, Insect Block 28 (28.5% DEET, 4.5 h). According to significantly promising results, including highly effective repellency and no potential skin irritation or other side effects, the G10 formula is a worthwhile product that has the promise of being developed for commercialized registration. This developed AHE product could be an acceptable and affordable alternative to conventional synthetic chemicals in preventing mosquito bites, and in turn, helping to interrupt mosquito-borne disease transmission.

  2. Final report on the safety assessment of benzaldehyde.

    PubMed

    Andersen, Alan

    2006-01-01

    Benzaldehyde is an aromatic aldehyde used in cosmetics as a denaturant, a flavoring agent, and as a fragrance. Currently used in only seven cosmetic products, its highest reported concentration of use was 0.5% in perfumes. Benzaldehyde is a generally regarded as safe (GRAS) food additive in the United States and is accepted as a flavoring substance in the European Union. Because Benzaldehyde rapidly metabolizes to Benzoic Acid in the skin, the available dermal irritation and sensitization data demonstrating no adverse reactions to Benzoic Acid were considered supportive of the safety of Benzaldehyde. Benzaldehyde is absorbed through skin and by the lungs, distributes to all well-perfused organs, but does not accumulate in any specific tissue type. After being metabolized to benzoic acid, conjugates are formed with glycine or glucuronic acid, and excreted in the urine. Little acute toxicity was seen. The oral LD(50) of Benzaldehyde in rats and mice ranged from 800 to 2850 mg/kg. The intraperitoneal LD(50) in white rats was 3265 mg/kg. In short-term oral studies, the no observed adverse effect level (NOAEL) was 400 mg/kg in rats and mice. In subchronic oral studies, the NOAEL was 400 mg/kg in rats and 600 mg/kg in mice. In a 16-week feeding study, rats given up to 10,000 ppm showed no signs of toxicity. Repeated inhalation of volatilized Benzaldehyde produced ocular and nasal irritation at 500 ppm and death in rabbits at 750 ppm. Undiluted Benzaldehyde was irritating to rabbit eyes, causing edema, erythema, and pain. Benzaldehyde was determined not to be a contact sensitizer, but did produce allergic reactions in a maximization test. Clinical reports of allergy to Benzaldehyde are rare. Benzoic Acid did not produce irritation or sensitization reactions in human clinical studies. Benzoic Acid also failed to produce reactions in phototoxicity and photosensitization tests. Neither Benzaldehyde, Benzoic Acid, nor Sodium Benzoate are reproductive or developmental toxicants at doses that are nontoxic to the mother. In a behavioral study, blood levels of 0.12 ng/ml Benzaldehyde produced a 44% reduction in motor activity in mice. Benzaldehyde did not produce mutations in bacterial assays, but did produce chromosomal abnormalities in Chinese hamster cells and increased mutations in a mouse lymphoma forward mutation assay. Benzaldehyde was evaluated by the National Toxicology Program, which found no evidence of carcinogenicity in rats, and some evidence of carcinogenicity in mice. Several studies have suggested that Benzaldehyde can have carcinostatic or antitumor properties. Overall, at the concentrations used in cosmetics, Benzaldehyde was not considered a carcinogenic risk to humans. Although there are limited irritation and sensitization data available for Benzaldehyde, the available dermal irritation and sensitization data and ultraviolet (UV) absorption and phototoxicity data demonstrating no adverse reactions to Benzoic Acid support the safety of Benzaldehyde as currently used in cosmetic products.

  3. Prevention of Dengue fever through plant based mosquito repellent Clausena dentata (Willd.) M. Roem (Family: Rutaceae) essential oil against Aedes aegypti l. (Diptera: Culicidae) mosquito.

    PubMed

    Rajkumar, S; Jebanesan, A

    2010-03-01

    Plant based repellent against mosquito borne diseases are used recently because synthetic repellents cause side effects like breathing problem, eye irritation, head ache, cough, etc. The use of natural products for dengue control would protect the environment, reduce dependence on expensive synthetic repellents and also generate local employment. Essential oil was isolated by steam distillation which was used against the bites of Aedes aegypti and duration of protection period was assessed. Skin-irritant potential test was also conducted on 25 healthy volunteers by using four-point scale. The increase in the concentrations of essential oil increased the mean protection time against the bites of Aedes aegypti. The lowest mean protection time was 180.0 min for 2.5% and highest time of 255.0 min for 10%. The mean score of zero for skin-irritant potential test for all the concentrations indicated that the essential oil did not cause irritation to human skin. Results indicated that the use of plant based repellent for the control of dengue fever would replace the currently used synthetic repellents which causes many side effects.

  4. Assessment of Irritation and Sensitization Potential of Eight Baby Skin Care Products.

    PubMed

    Galzote, Carlos; Thomas, Mini; Sachdev, Mukta

    2016-10-01

    Ethnic differences in skin sensitivity suggest that greater emphasis be focused on understanding a product's effect in diverse populations. The irritation and/or sensitization potential of 8 baby skin care products in Indian adults were evaluated using cumulative irritation tests (CIT) and human repeat insult patch testing (HRIPT) protocols. Healthy males or females aged 18 to 65 years of Indian ethnicity were treated with each of 6 products (cream, hair oil, lotion, body wash, shampoo, and baby soap) using CIT (n = 25) and HRIPT (n = 200). Baby powder and baby oil were evaluated by CIT (n = 25) and HRIPT (n = 107) in separate studies. CITs were conducted over 14 days; HRIPTs were conducted over 10 weeks. In both CIT and HRIPT, most products were considered mild, with no irritation. Baby soap and powder elicited reactions in the HRIPT induction phase, with positive challenge phase reactions (3 subjects), but were affirmed to be nonallergenic in the rechallenge phase. In these studies, 8 baby skin care products were evaluated by both CIT and HRIPT in Indian adults. The results of the studies indicated that all of the tested products were nonallergenic and nonirritating.

    J Drugs Dermatol. 2016;15(10):1244-1248.

  5. Retinoids activate the irritant receptor TRPV1 and produce sensory hypersensitivity

    PubMed Central

    Yin, Shijin; Luo, Jialie; Qian, Aihua; Du, Junhui; Yang, Qing; Zhou, Shentai; Yu, Weihua; Du, Guangwei; Clark, Richard B.; Walters, Edgar T.; Carlton, Susan M.; Hu, Hongzhen

    2013-01-01

    Retinoids are structurally related derivatives of vitamin A and are required for normal vision as well as cell proliferation and differentiation. Clinically, retinoids are effective in treating many skin disorders and cancers. Application of retinoids evokes substantial irritating side effects, including pain and inflammation; however, the precise mechanisms accounting for the sensory hypersensitivity are not understood. Here we show that both naturally occurring and synthetic retinoids activate recombinant or native transient receptor potential channel vanilloid subtype 1 (TRPV1), an irritant receptor for capsaicin, the pungent ingredient of chili peppers. In vivo, retinoids produced pain-related behaviors that were either eliminated or significantly reduced by genetic or pharmacological inhibition of TRPV1 function. These findings identify TRPV1 as an ionotropic receptor for retinoids and provide cellular and molecular insights into retinoid-evoked hypersensitivity. These findings also suggest that selective TRPV1 antagonists are potential therapeutic drugs for treating retinoid-induced sensory hypersensitivity. PMID:23925292

  6. Experimental support that ocular tremor in Parkinson's disease does not originate from head movement.

    PubMed

    Gitchel, George T; Wetzel, Paul A; Qutubuddin, Abu; Baron, Mark S

    2014-07-01

    Our recent report of ocular tremor in Parkinson's disease (PD) has raised considerable controversy as to the origin of the tremor. Using an infrared based eye tracker and a magnetic head tracker, we reported that ocular tremor was recordable in PD subjects with no apparent head tremor. However, other investigators suggest that the ocular tremor may represent either transmitted appendicular tremor or subclinical head tremor inducing the vestibulo-ocular reflex (VOR). The present study aimed to further investigate the origin of ocular tremor in PD. Eye movements were recorded in 8 PD subjects both head free, and with full head restraint by means of a head holding device and a dental impression bite plate. Head movements were recorded independently using both a high sensitivity tri-axial accelerometer and a magnetic tracking system, each synchronized to the eye tracker. Ocular tremor was observed in all 8 PD subjects and was not influenced by head free and head fixed conditions. Both magnetic tracking and accelerometer recordings supported that the ocular tremor was fully independent of head position. The present study findings support our initial findings that ocular tremor is a fundamental feature of PD unrelated to head movements. Although the utility of ocular tremor for diagnostic purposes requires validation, current findings in large cohorts of PD subjects suggest its potential as a reliable clinical biomarker. Published by Elsevier Ltd.

  7. Tiered application of the neutral red release and EpiOcular™ assays for evaluating the eye irritation potential of agrochemical formulations.

    PubMed

    Settivari, Raja S; Amado, Ricardo Acosta; Corvaro, Marco; Visconti, Nicolo R; Kan, Lynn; Carney, Edward W; Boverhof, Darrell R; Gehen, Sean C

    2016-11-01

    Agrochemical formulations have been underrepresented in validation efforts for implementing alternative eye irritation approaches but represent a significant opportunity to reduce animal testing. This study assesses the utility of the neutral red release assay (NRR) and EpiOcular™ assay (EO) for predicting the eye irritation potential of 64 agrochemical formulations relative to Draize data. In the NRR, formulations with an NRR50 value ≤ 50 mg/mL were categorized as UN GHS Cat 1 and those >250 mg/mL were classified as UN GHS Non Classified (NC). The accuracy, sensitivity, and specificity were 78, 85 and 76% and 73, 85 and 61% for identifying UN GHS 1 and NC formulations, respectively. Specificity was poor for formulations with NRR50 > 50 to ≤250 mg/mL. The EO (ET-40 method) was explored to differentiate formulations that were UN GHS 1/2 and UN GHS NC. The EO resulted in accuracy, sensitivity, and specificity of 65%, 58% and 75% for identifying UN GHS NC formulations. To improve the overall performance, the assays were implemented using a tiered-approach where the NRR was run as a first-tier followed by the EO. The tiered-approach resulted in improved accuracy (75%) and balanced sensitivity (73%) and specificity (77%) for distinguishing between irritating and non-irritating agrochemical formulations. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Nontuberculous Mycobacterial Ocular Infections: A Systematic Review of the Literature

    PubMed Central

    Kheir, Wajiha J.; Sheheitli, Huda; Abdul Fattah, Maamoun; Hamam, Rola N.

    2015-01-01

    Nontuberculous or atypical mycobacterial ocular infections have been increasing in prevalence over the past few decades. They are known to cause periocular, adnexal, ocular surface and intraocular infections and are often recalcitrant to medical therapy. These infections can potentially cause detrimental outcomes, in part due to a delay in diagnosis. We review 174 case reports and series on nontuberculous mycobacterial (NTM) ocular infections and discuss etiology, microbiology, risk factors, diagnosis, clinical presentation, and treatment of these infections. History of interventions, trauma, foreign bodies, implants, contact lenses, and steroids are linked to NTM ocular infections. Steroid use may prolong the duration of the infection and cause poorer visual outcomes. Early diagnosis and initiation of treatment with multiple antibiotics are necessary to achieve the best visual outcome. PMID:26106601

  9. Evaluation of the irritancy and hypersensitivity potential following topical application of didecyldimethylammonium chloride

    PubMed Central

    Anderson, Stacey E.; Shane, Hillary; Long, Carrie; Lukomska, Ewa; Meade, B. Jean; Marshall, Nikki B.

    2016-01-01

    Didecyldimethylammonium chloride (DDAC) is a dialkyl-quaternary ammonium compound that is used in numerous products for its bactericidal, virucidal and fungicidal properties. There have been clinical reports of immediate and delayed hypersensitivity reactions in exposed individuals; however, the sensitization potential of DDAC has not been thoroughly investigated. The purpose of these studies was to evaluate the irritancy and sensitization potential of DDAC following dermal exposure in a murine model. DDAC induced significant irritancy (0.5 and 1%), evaluated by ear swelling in female Balb/c mice. Initial evaluation of the sensitization potential was conducted using the local lymph node assay (LLNA) at concentrations ranging from 0.0625–1%. A concentration-dependent increase in lymphocyte proliferation was observed with a calculated EC3 value of 0.17%. Dermal exposure to DDAC did not induce increased production of IgE as evaluated by phenotypic analysis of draining lymph node B-cells (IgE+B220+) and measurement of total serum IgE levels. Additional phenotypic analyses revealed significant and dose-responsive increases in the absolute number of B-cells, CD4+ T-cells, CD8+ T-cells and dendritic cells in the draining lymph nodes, along with significant increases in the percentage of B-cells (0.25% and 1% DDAC) at Day 10 following 4 days of dermal exposure. There was also a significant and dose-responsive increase in the number of activated CD44 + CD4 + and CD8+ T-cells and CD86+ B-cells and dendritic cells following exposure to all concentrations of DDAC. These results demonstrate the potential for development of irritation and hypersensitivity responses to DDAC following dermal exposure and raise concerns about the use of this chemical and other quaternary ammonium compounds that may elicit similar effects. PMID:27216637

  10. Republished review: Gene therapy for ocular diseases.

    PubMed

    Liu, Melissa M; Tuo, Jingsheng; Chan, Chi-Chao

    2011-07-01

    The eye is an easily accessible, highly compartmentalised and immune-privileged organ that offers unique advantages as a gene therapy target. Significant advancements have been made in understanding the genetic pathogenesis of ocular diseases, and gene replacement and gene silencing have been implicated as potentially efficacious therapies. Recent improvements have been made in the safety and specificity of vector-based ocular gene transfer methods. Proof-of-concept for vector-based gene therapies has also been established in several experimental models of human ocular diseases. After nearly two decades of ocular gene therapy research, preliminary successes are now being reported in phase 1 clinical trials for the treatment of Leber congenital amaurosis. This review describes current developments and future prospects for ocular gene therapy. Novel methods are being developed to enhance the performance and regulation of recombinant adeno-associated virus- and lentivirus-mediated ocular gene transfer. Gene therapy prospects have advanced for a variety of retinal disorders, including retinitis pigmentosa, retinoschisis, Stargardt disease and age-related macular degeneration. Advances have also been made using experimental models for non-retinal diseases, such as uveitis and glaucoma. These methodological advancements are critical for the implementation of additional gene-based therapies for human ocular diseases in the near future.

  11. Gene therapy for ocular diseases.

    PubMed

    Liu, Melissa M; Tuo, Jingsheng; Chan, Chi-Chao

    2011-05-01

    The eye is an easily accessible, highly compartmentalised and immune-privileged organ that offers unique advantages as a gene therapy target. Significant advancements have been made in understanding the genetic pathogenesis of ocular diseases, and gene replacement and gene silencing have been implicated as potentially efficacious therapies. Recent improvements have been made in the safety and specificity of vector-based ocular gene transfer methods. Proof-of-concept for vector-based gene therapies has also been established in several experimental models of human ocular diseases. After nearly two decades of ocular gene therapy research, preliminary successes are now being reported in phase 1 clinical trials for the treatment of Leber congenital amaurosis. This review describes current developments and future prospects for ocular gene therapy. Novel methods are being developed to enhance the performance and regulation of recombinant adeno-associated virus- and lentivirus-mediated ocular gene transfer. Gene therapy prospects have advanced for a variety of retinal disorders, including retinitis pigmentosa, retinoschisis, Stargardt disease and age-related macular degeneration. Advances have also been made using experimental models for non-retinal diseases, such as uveitis and glaucoma. These methodological advancements are critical for the implementation of additional gene-based therapies for human ocular diseases in the near future.

  12. Ocular chemical injuries and their management.

    PubMed

    Singh, Parul; Tyagi, Manoj; Kumar, Yogesh; Gupta, K K; Sharma, P D

    2013-05-01

    Chemical burns represent potentially blinding ocular injuries and constitute a true ocular emergency requiring immediate assessment and initiation of treatment. The majority of victims are young and exposure occurs at home, work place and in association with criminal assaults. Alkali injuries occur more frequently than acid injuries. Chemical injuries of the eye produce extensive damage to the ocular surface epithelium, cornea, anterior segment and limbal stem cells resulting in permanent unilateral or bilateral visual impairment. Emergency management if appropriate may be single most important factor in determining visual outcome. This article reviews the emergency management and newer techniques to improve the prognosis of patients with chemical injuries.

  13. Antinociceptive and free radical scavenging activities of Cocos nucifera L. (Palmae) husk fiber aqueous extract.

    PubMed

    Alviano, Daniela S; Rodrigues, Karen F; Leitão, Suzana G; Rodrigues, Marcio L; Matheus, Maria Eline; Fernandes, Patrícia D; Antoniolli, Angelo R; Alviano, Celuta S

    2004-06-01

    In the current study, the analgesic and free radical scavenging properties of an aqueous extract from the husk fiber of Cocos nucifera L. (Palmae) were demonstrated by the use of in vivo and in vitro models. The orally administered Cocos nucifera aqueous extract (200 or 400 mg/kg) inhibited the acetic acid-induced writhing response in mice. Tail flick and hot plate assays demonstrated that treatment of animals with this plant extract at 200 mg/kg induced attenuation in the response to a heat stimulus. A LD(50) of 2.30 g/kg was obtained in acute toxicity tests. Topic treatment of rabbits with the Cocos nucifera extract indicated that it does not induce any significant dermic or ocular irritation. In vitro experiments using the 2,2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH) photometric assay demonstrated that this plant extract also possesses free radical scavenging properties.

  14. Noncontact detection of dry eye using a custom designed infrared thermal image system

    NASA Astrophysics Data System (ADS)

    Su, Tai Yuan; Hwa, Chen Kerh; Liu, Po Hsuan; Wu, Ming Hong; Chang, David O.; Su, Po Fang; Chang, Shu Wen; Chiang, Huihua Kenny

    2011-04-01

    Dry eye syndrome is a common irritating eye disease. Current clinical diagnostic methods are invasive and uncomfortable for patients. This study developed a custom designed noncontact infrared (IR) thermal image system to measure the spatial and temporal variation of the ocular surface temperature over a 6-second eye-open period. This research defined two parameters: the temperature difference value and the compactness value to represent the temperature change and the irregularity of the temperature distribution on the tear film. Using these two parameters, this study achieved discrimination results for the dry eye and the normal eye groups; the sensitivity is 0.84, the specificity is 0.83, and the receiver operating characteristic area is 0.87. The results suggest that the custom designed IR thermal image system may be used as an effective tool for noncontact detection of dry eye.

  15. Noncontact detection of dry eye using a custom designed IR thermal image system

    NASA Astrophysics Data System (ADS)

    Su, Tai Yuan; Chen, Kerh Hwa; Liu, Po Hsuan; Wu, Ming Hong; Chang, David O.; Chiang, Huihua

    2011-03-01

    Dry eye syndrome is a common irritating eye disease. Current clinical diagnostic methods are invasive and uncomfortable to patients. A custom designed noncontact infrared (IR) thermal image system was developed to measure the spatial and temporal variation of the ocular surface temperature over a 6-second eye-opening period. We defined two parameters: the temperature difference value and the compactness value to represent the degree of the temperature change and irregularity of the temperature distribution on the tear film. By using these two parameters, in this study, a linear discrimination result for the dry eye and the normal eye groups; the sensitivity is 0.9, the specificity is 0.86 and the receiver operating characteristic (ROC) area is 0.91. The result suggests that the custom designed IR thermal image system may be used as an effective tool for noncontact detection of dry eye.

  16. Efficacy and Tolerability of Pharmacotherapy Options for the Treatment of Irritability in Autistic Children

    PubMed Central

    Kirino, Eiji

    2014-01-01

    Children with autism have a high rate of irritability and aggressive symptoms. Irritability or self-injurious behavior can result in significant harm to those affected, as well as to marked distress for their families. This paper provides a literature review regarding the efficacy and tolerability of pharmacotherapy for the treatment of irritability in autistic children. Although antipsychotics have not yet been approved for the treatment of autistic children by many countries, they are often used to reduce symptoms of behavioral problems, including irritability, aggression, hyperactivity, and panic. However, among antipsychotics, the Food and Drug Administration has approved only risperidone and aripiprazole to treat irritability in autism. Among atypical antipsychotics, olanzapine and quetiapine are limited in their use for autism spectrum disorders in children because of high incidences of weight gain and sedation. In comparison, aripiprazole and ziprasidone cause less weight gain and sedation. However, potential QTc interval prolongation with ziprasidone has been reported. Contrary to ziprasidone, no changes were evident in the QT interval in any of the trials for aripiprazole. However, head-to-head comparison studies are needed to support that aripiprazole may be a promising drug that can be used to treat irritability in autistic children. On the other hand, risperidone has the greatest amount of evidence supporting it, including randomized controlled trials; thus, its efficacy and tolerability has been established in comparison with other agents. Further studies with risperidone as a control drug are needed. PMID:24932108

  17. Recent Perspectives in Ocular Drug Delivery

    PubMed Central

    Gaudana, Ripal; Jwala, J.; Boddu, Sai H. S.; Mitra, Ashim K.

    2015-01-01

    Anatomy and physiology of the eye makes it a highly protected organ. Designing an effective therapy for ocular diseases, especially for the posterior segment, has been considered as a formidable task. Limitations of topical and intravitreal route of administration have challenged scientists to find alternative mode of administration like periocular routes. Transporter targeted drug delivery has generated a great deal of interest in the field because of its potential to overcome many barriers associated with current therapy. Application of nanotechnology has been very promising in the treatment of a gamut of diseases. In this review, we have briefly discussed several ocular drug delivery systems such as microemulsions, nanosuspensions, nanoparticles, liposomes, niosomes, dendrimers, implants, and hydrogels. Potential for ocular gene therapy has also been described in this article. In near future, a great deal of attention will be paid to develop non-invasive sustained drug release for both anterior and posterior segment eye disorders. A better understanding of nature of ocular diseases, barriers and factors affecting in vivo performance, would greatly drive the development of new delivery systems. Current momentum in the invention of new drug delivery systems hold a promise towards much improved therapies for the treatment of vision threatening disorders. PMID:18758924

  18. Cytotoxicity and genotoxicity of bacterial magnetosomes against human retinal pigment epithelium cells

    NASA Astrophysics Data System (ADS)

    Qi, Lei; Lv, Xiujuan; Zhang, Tongwei; Jia, Peina; Yan, Ruiying; Li, Shuli; Zou, Ruitao; Xue, Yuhua; Dai, Liming

    2016-06-01

    A variety of nanomaterials have been developed for ocular diseases. The ability of these nanomaterials to pass through the blood-ocular barrier and their biocompatibility are essential characteristics that must be considered. Bacterial magnetosomes (BMs) are a type of biogenic magnetic nanomaterials synthesized by magnetotactic bacteria. Due to their unique biomolecular membrane shell and narrow size distribution of approximately 30 nm, BMs can pass through the blood-brain barrier. The similarity of the blood-ocular barrier to the blood-brain barrier suggests that BMs have great potential as treatments for ocular diseases. In this work, BMs were isolated from magnetotactic bacteria and evaluated in various cytotoxicity and genotoxicity studies in human retinal pigment epithelium (ARPE-19) cells. The BMs entered ARPE-19 cells by endocytosis after a 6-h incubation and displayed much lower cytotoxicity than chemically synthesized magnetic nanoparticles (MNPs). MNPs exhibited significantly higher genotoxicity than BMs and promoted the expression of Bax (the programmed cell death acceleration protein) and the induction of greater cell necrosis. In BM-treated cells, apoptosis tended to be suppressed via increased expression of the Bcl-2 protein. In conclusion, BMs display excellent biocompatibility and potential for use in the treatment of ocular diseases.

  19. Ocular Stem Cell Research from Basic Science to Clinical Application: A Report from Zhongshan Ophthalmic Center Ocular Stem Cell Symposium

    PubMed Central

    Ouyang, Hong; Goldberg, Jeffrey L.; Chen, Shuyi; Li, Wei; Xu, Guo-Tong; Li, Wei; Zhang, Kang; Nussenblatt, Robert B.; Liu, Yizhi; Xie, Ting; Chan, Chi-Chao; Zack, Donald J.

    2016-01-01

    Stem cells hold promise for treating a wide variety of diseases, including degenerative disorders of the eye. The eye is an ideal organ for stem cell therapy because of its relative immunological privilege, surgical accessibility, and its being a self-contained system. The eye also has many potential target diseases amenable to stem cell-based treatment, such as corneal limbal stem cell deficiency, glaucoma, age-related macular degeneration (AMD), and retinitis pigmentosa (RP). Among them, AMD and glaucoma are the two most common diseases, affecting over 200 million people worldwide. Recent results on the clinical trial of retinal pigment epithelial (RPE) cells from human embryonic stem cells (hESCs) and induced pluripotent stem cells (iPSCs) in treating dry AMD and Stargardt’s disease in the US, Japan, England, and China have generated great excitement and hope. This marks the beginning of the ocular stem cell therapy era. The recent Zhongshan Ophthalmic Center Ocular Stem Cell Symposium discussed the potential applications of various stem cell types in stem cell-based therapies, drug discoveries and tissue engineering for treating ocular diseases. PMID:27102165

  20. Emerging toxicities in the treatment of non-small cell lung cancer: ocular disorders.

    PubMed

    Agustoni, Francesco; Platania, Marco; Vitali, Milena; Zilembo, Nicoletta; Haspinger, Eva; Sinno, Valentina; Gallucci, Rosaria; de Braud, Filippo; Garassino, Marina Chiara

    2014-02-01

    The treatment of advanced disease (stage IIIb and IV) of non-small cell lung cancer (NSCLC) is based on systemic treatment with platinum-based chemotherapy or biological compounds depending on the disease molecular profile. In the last few years, intensive investigational efforts in anticancer therapy have led to the registration of new active chemotherapeutic agents, combination regimens, and biological drugs, expanding choices for customizing individual treatment. However, the introduction of new drugs in the clinical setting has led to several new toxicities, creating some difficulties in daily management. Among these, ocular toxicity is generally overlooked as more common toxicities such as myelosuppression, stomatitis, diarrhea, vomiting, "hand-foot syndrome", and neurological alterations attract greater attention. Ophthalmic complications from cytotoxic chemotherapeutics are rare, transient, and of mild/moderate intensity but irreversible acute disorders are possible. The best way to prevent potential irreversible visual complications is an awareness of the potential for ocular toxicity because dose reductions or early drug cessation can prevent serious ocular complications in the majority of cases. However, given the novelty of many therapeutic agents and the complexity of ocular pathology, oncologists may be unfamiliar with these adverse effects of anticancer therapy. Although toxicities from chemotherapy are generally intense but short lasting, toxicities related to targeted drugs are often milder but longer lasting and can persist throughout treatment. Here we review the principal clinical presentations of ocular toxicity arising from chemotherapy [1-3], target therapies [4], and newly developed drugs and provide some recommendations for monitoring and management of ocular toxicity. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Predictive performance of the Vitrigel‐eye irritancy test method using 118 chemicals

    PubMed Central

    Yamaguchi, Hiroyuki; Kojima, Hajime

    2015-01-01

    Abstract We recently developed a novel Vitrigel‐eye irritancy test (EIT) method. The Vitrigel‐EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time‐dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel‐EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel‐EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false‐negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false‐positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO‐1, a tight junction‐associated protein and MUC1, a cell membrane‐spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false‐positive chemicals, suggesting that such false‐positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel‐EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel‐EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. PMID:26472347

  2. Evaluation of the skin irritation using a DNA microarray on a reconstructed human epidermal model.

    PubMed

    Niwa, Makoto; Nagai, Kanji; Oike, Hideaki; Kobori, Masuko

    2009-02-01

    To avoid the need to use animals to test the skin irritancy potential of chemicals and cosmetics, it is important to establish an in vitro method based on the reconstructed human epidermal model. To evaluate skin irritancy efficiently and sensitively, we determined the gene expression induced by a topically-applied mild irritant sodium dodecyl sulfate (SDS) in a reconstructed human epidermal model LabCyte EPI-MODEL (LabCyte) using a DNA microarray carrying genes that were related to inflammation, immunity, stress and housekeeping. The expression and secretion of IL-1alpha in reconstructed human epidermal culture is known to be induced by irritation. We detected the induction of IL-1alpha expression and its secretion into the cell culture medium by treatment with 0.075% SDS for 18 h in LabCyte culture using DNA microarray, quantitative reverse-transcription polymerase chain reaction (RT-PCR) and ELISA. DNA microarray analysis indicated that the expression of 10 of the 205 genes carried on the DNA microarray was significantly induced in a LabCyte culture by 0.05% or 0.075% SDS irritation for 18 h. RT-PCR analysis confirmed that SDS treatment significantly induced the expressions of interleukin-1 receptor antagonist (IL-1RN), FOS-like antigen 1 (FOSL1), heat shock 70 kDa protein 1A (HSPA1) and myeloid differentiation primary response gene (88) (MYD88), as well as the known marker genes for irritation IL-1beta and IL-8 in a LabCyte culture. Our results showed that a DNA microarray is a useful tool for efficiently evaluating mild skin irritation using a reconstructed human epidermal model.

  3. Toxic keratopathy associated with abuse of low-dose anesthetic: a case report.

    PubMed

    Chen, Hsiao-Ting; Chen, Ko-Hua; Hsu, Wen-Ming

    2004-07-01

    To describe the clinical course and treatment of toxic keratopathy associated with abuse of topical anesthetic at a very low concentration, 0.05%. Case report. A 47-year-old female systemic lupus erythematosus (SLE) patient with blurred vision and irritated right eye was referred to the ophthalmology department of our hospital. Under slit-lamp microscope, a 5.5 x 4.5 mm central corneal epithelial defect with underlying infiltrative and opaque stroma was noted in her right eye. Two weeks before, a corneal ulcer was diagnosed, and oxybuprocaine 0.05% (Lacrimin, Santen, Osaka, Japan) eye drops were prescribed 4 times daily but used every 5 to 10 minutes because the right eye was severely irritated. She was admitted immediately under the impression of toxic corneal ulcer. Preservative-free lubricants and prophylactic topical antibiotics 4 times daily were applied. Therapeutic soft contact lens was started after no infective agents were detected. Two weeks later, the stromal infiltration subsided, and the corneal epithelium was slowly healing, but superficial punctate epithelial defects at the lesion site persisted for another 6 months. The vision of her right eye improved from finger-counting at a 30-cm distance to 20/1200 with correction. Toxic keratopathy may result from abuse of topically administered anesthetics even at a very low concentration, 0.05%. Because this SLE patient has tear problems, we suggest that topical anesthetics must be used very cautiously and never prescribed to patients with dry eyes where the integrity of ocular surface is altered.

  4. Evaluation of SARs for the prediction of eye irritation/corrosion potential: structural inclusion rules in the BfR decision support system.

    PubMed

    Tsakovska, I; Saliner, A Gallegos; Netzeva, T; Pavan, M; Worth, A P

    2007-01-01

    The proposed REACH regulation within the European Union (EU) aims to minimise the number of laboratory animals used for human hazard and risk assessment while ensuring adequate protection of human health and the environment. One way to achieve this goal is to develop non-testing methods, such as (quantitative) structure-activity relationships ([Q]SARs), suitable for identifying toxicological hazard from chemical structure and physicochemical properties alone. A database containing data submitted within the EU New Chemicals Notification procedure was compiled by the German Bundesinstitut für Risikobewertung (BfR). On the basis of these data, the BfR built a decision support system (DSS) for the prediction of several toxicological endpoints. For the prediction of eye irritation and corrosion potential, the DSS contains 31 physicochemical exclusion rules evaluated previously by the European Chemicals Bureau (ECB), and 27 inclusion rules that define structural alerts potentially responsible for eye irritation and/or corrosion. This work summarises the results of a study carried out by the ECB to assess the performance of the BfR structural rulebase. The assessment included: (a) evaluation of the structural alerts by using the training set of 1341 substances with experimental data for eye irritation and corrosion; and (b) external validation by using an independent test set of 199 chemicals. Recommendations are made for the further development of the structural rules in order to increase the overall predictivity of the DSS.

  5. Ocular Chromatic Aberrations and Their Effects on Polychromatic Retinal Image Quality

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoxiao

    Previous studies of ocular chromatic aberrations have concentrated on chromatic difference of focus (CDF). Less is known about the chromatic difference of image position (CDP) in the peripheral retina and no experimental attempt has been made to measure the ocular chromatic difference of magnification (CDM). Consequently, theoretical modelling of human eyes is incomplete. The insufficient knowledge of ocular chromatic aberrations is partially responsible for two unsolved applied vision problems: (1) how to improve vision by correcting ocular chromatic aberration? (2) what is the impact of ocular chromatic aberration on the use of isoluminance gratings as a tool in spatial-color vision?. Using optical ray tracing methods, MTF analysis methods of image quality, and psychophysical methods, I have developed a more complete model of ocular chromatic aberrations and their effects on vision. The ocular CDM was determined psychophysically by measuring the tilt in the apparent frontal parallel plane (AFPP) induced by interocular difference in image wavelength. This experimental result was then used to verify a theoretical relationship between the ocular CDM, the ocular CDF and the entrance pupil of the eye. In the retinal image after correcting the ocular CDF with existing achromatizing methods, two forms of chromatic aberration (CDM and chromatic parallax) were examined. The CDM was predicted by theoretical ray tracing and measured with the same method used to determine ocular CDM. The chromatic parallax was predicted with a nodal ray model and measured with the two-color vernier alignment method. The influence of these two aberrations on polychromatic MTF were calculated. Using this improved model of ocular chromatic aberration, luminance artifacts in the images of isoluminance gratings were calculated. The predicted luminance artifacts were then compared with experimental data from previous investigators. The results show that: (1) A simple relationship exists between two major chromatic aberrations and the location of the pupil; (2) The ocular CDM is measurable and varies among individuals; (3) All existing methods to correct ocular chromatic aberration face another aberration, chromatic parallax, which is inherent in the methodology; (4) Ocular chromatic aberrations have the potential to contaminate psychophysical experimental results on human spatial-color vision.

  6. Voriconazole-Loaded Nanostructured Lipid Carriers for Ocular Drug Delivery.

    PubMed

    Andrade, Lígia M; Rocha, Kamilla A D; De Sá, Fernando A P; Marreto, Ricardo N; Lima, Eliana M; Gratieri, Tais; Taveira, Stephânia F

    2016-06-01

    To design and evaluate the potential of a topical delivery system for ocular administration of voriconazole, based on cationic nanostructured lipid carriers (NLCs). NLC dispersions composed of glyceryl behenate/capric caprylic triglyceride, polysorbate 80, sorbitan trioleate, and cetylpyridinium chloride were obtained and characterized. Ex vivo permeations experiments were performed to evaluate their drug delivery potential. NLCs presented a mean diameter of 250.2 ± 03.1 nm, narrow polydispersity index (0.288 ± 0.03), positive zeta potential (31.22 ± 3.8 mV), and over 75% encapsulation efficiency. Ex vivo ocular experiments proved that NLCs were able to deliver therapeutically relevant drug amounts to the cornea after only 30 minutes (13.88 ± 0.24 μg/cm). The formulation was nonexpensive, easy to prepare, and composed of well-tolerated and accepted excipients. Further in vivo experiments are necessary to confirm the improved performance and tolerability of the formulation.

  7. Oenothera laciniata inhibits lipopolysaccharide induced production of nitric oxide, prostaglandin E2, and proinflammatory cytokines in RAW264.7 macrophages.

    PubMed

    Yoon, Weon-Jong; Ham, Young Min; Yoo, Byoung-Sam; Moon, Ji-Young; Koh, Jaesook; Hyun, Chang-Gu

    2009-04-01

    We elucidated the pharmacological and biological effects of Oenothera laciniata extracts on the production of inflammatory mediators in macrophages. The CH(2)Cl(2) fraction of O. laciniata extract effectively inhibited LPS-induced NO, PGE(2), and proinflammatory cytokine production in RAW264.7 cells. These inhibitory effects of the CH(2)Cl(2) fraction of O. laciniata were accompanied by decreases in the expression of iNOS and COX-2 proteins and iNOS, COX-2, TNF-alpha, IL-1beta, and IL-6 mRNA. Asiatic acid and quercetin were present in the HPLC fingerprint of the O. laciniata extract. We tested the potential application of O. laciniata extract as a cosmetic material by performing primary skin irritation tests. In New Zealand white rabbits, primary irritation tests revealed that application of O. laciniata extracts (1%) did not induce erythema or edema formation. Human skin primary irritation tests were performed on the normal skin (upper back) of 30 volunteers to determine if any material in O. laciniata extracts had irritation or sensitization potential. In these assays, O. laciniata extracts did not induce any adverse reactions. Based on these results, we suggest that O. laciniata extracts be considered possible anti-inflammatory candidates for topical application.

  8. Accounting for Ethnicity-Related Differences in Ocular Surface Integrity as a Step Toward Understanding Contact Lens Discomfort.

    PubMed

    Chan, Stefanie M; Svitova, Tatyana F; Lin, Meng C

    2017-01-01

    Contact lens discomfort is a common problem that can lead to unsuccessful or limited contact lens wear. Although many factors may contribute to contact lens discomfort, limited research has explored the influence of ethnicity-related differences in the anatomy and physiology of the ocular surface. Therefore, we performed a search of the literature in PubMed using key words related to "ocular surface" paired with the terms "race" and "ethnicity." The goal of this review was to determine potential areas of research regarding ethnicity differences, particularly between Asian and non-Asian eyes, in ocular surface integrity to advance our understanding of contact lens discomfort.

  9. Ocular toxicities associated with targeted anticancer agents: an analysis of clinical data with management suggestions

    PubMed Central

    Fu, Chen; Gombos, Dan S; Lee, Jared; George, Goldy C; Hess, Kenneth; Whyte, Andrew; Hong, David S

    2017-01-01

    Ocular toxicities are among the most common adverse events resulting from targeted anticancer agents and are becoming increasingly relevant in the management of patients on these agents. The purpose of this study is to provide a framework for management of these challenging toxicities based on objective data from FDA labels and from analysis of the literature. All oncologic drugs approved by the FDA up to March 14, 2015, were screened for inclusion. A total of 16 drugs (12 small-molecule drugs and 4 monoclonal antibodies) were analyzed for ocular toxicity profiles based on evidence of ocular toxicity. Trials cited by FDA labels were retrieved, and a combination search in Medline, Google Scholar, the Cochrane database, and the NIH Clinical Trials Database was conducted. The majority of ocular toxicities reported were low severity, and the most common were conjunctivitis and “visual disturbances.” However, severe events including incidents of blindness, retinal vascular occlusion, and corneal ulceration occurred. The frequency and severity at which ocular toxicities occur merits a more multidisciplinary approach to managing patients with agents that are known to cause ocular issues. We suggest a standardized methodology for referral and surveillance of patients who are potentially at risk of severe ocular toxicity. PMID:28938590

  10. A novel small molecule ameliorates ocular neovascularisation and synergises with anti-VEGF therapy.

    PubMed

    Sulaiman, Rania S; Merrigan, Stephanie; Quigley, Judith; Qi, Xiaoping; Lee, Bit; Boulton, Michael E; Kennedy, Breandán; Seo, Seung-Yong; Corson, Timothy W

    2016-05-05

    Ocular neovascularisation underlies blinding eye diseases such as retinopathy of prematurity, proliferative diabetic retinopathy, and wet age-related macular degeneration. These diseases cause irreversible vision loss, and provide a significant health and economic burden. Biologics targeting vascular endothelial growth factor (VEGF) are the major approach for treatment. However, up to 30% of patients are non-responsive to these drugs and they are associated with ocular and systemic side effects. Therefore, there is a need for small molecule ocular angiogenesis inhibitors to complement existing therapies. We examined the safety and therapeutic potential of SH-11037, a synthetic derivative of the antiangiogenic homoisoflavonoid cremastranone, in models of ocular neovascularisation. SH-11037 dose-dependently suppressed angiogenesis in the choroidal sprouting assay ex vivo and inhibited ocular developmental angiogenesis in zebrafish larvae. Additionally, intravitreal SH-11037 (1 μM) significantly reduced choroidal neovascularisation (CNV) lesion volume in the laser-induced CNV mouse model, comparable to an anti-VEGF antibody. Moreover, SH-11037 synergised with anti-VEGF treatments in vitro and in vivo. Up to 100 μM SH-11037 was not associated with signs of ocular toxicity and did not interfere with retinal function or pre-existing retinal vasculature. SH-11037 is thus a safe and effective treatment for murine ocular neovascularisation, worthy of further mechanistic and pharmacokinetic evaluation.

  11. Immune Privilege and Eye-Derived T-Regulatory Cells.

    PubMed

    Keino, Hiroshi; Horie, Shintaro; Sugita, Sunao

    2018-01-01

    Certain cellular components of the eye, such as neural retina, are unable to regenerate and replicate after destructive inflammation. Ocular immune privilege provides the eye with immune protection against intraocular inflammation in order to minimize the risk to vision integrity. The eye and immune system use strategies to maintain the ocular immune privilege by regulating the innate and adaptive immune response, which includes immunological ignorance, peripheral tolerance to eye-derived antigens, and intraocular immunosuppressive microenvironment. In this review, we summarize current knowledge regarding the molecular mechanism responsible for the development and maintenance of ocular immune privilege via regulatory T cells (Tregs), which are generated by the anterior chamber-associated immune deviation (ACAID), and ocular resident cells including corneal endothelial (CE) cells, ocular pigment epithelial (PE) cells, and aqueous humor. Furthermore, we examined the therapeutic potential of Tregs generated by RPE cells that express transforming growth factor beta (TGF- β ), cytotoxic T lymphocyte-associated antigen-2 alpha (CTLA-2 α ), and retinoic acid for autoimmune uveoretinitis and evaluated a new strategy using human RPE-induced Tregs for clinical application in inflammatory ocular disease. We believe that a better understanding of the ocular immune privilege associated with Tregs might offer a new approach with regard to therapeutic interventions for ocular autoimmunity.

  12. A controlled, three-part trial to investigate the barrier function and skin hydration properties of six skin protectants.

    PubMed

    Hoggarth, Andrew; Waring, Mike; Alexander, James; Greenwood, Amanada; Callaghan, Theresa

    2005-12-01

    In the treatment of incontinence dermatitis, a skin protectant primarily prevents skin breakdown due to moisture and biological irritants in urine and feces. To assess the barrier and skin hydration properties of six currently available skin protectants with different formulations, a controlled, three-phase study was conducted at a research facility in the UK among 18 healthy volunteers. The study addressed each product's efficacy against insult from a known irritant (sodium lauryl sulphate), skin hydration potential, and maintenance of skin barrier and barrier efficacy against maceration. Using white petrolatum (glycerin) as the positive control and untreated sites as the negative control, the results show that each one of the products tested has different performance properties. Products containing petrolatum demonstrated protection against irritants (P = 0.006 at 24 hours) and maceration (P < 0.005) and provided some skin hydration. Products containing dimethicone varied in protection against irritants (P < 0.005, or P > or = 0.806 at 24 hours) and have good skin hydration potential and low barrier efficacy (P > 0.500). Zinc oxide-based products showed protection against irritants (P < 0.005) but poor skin hydration and barrier properties to prevent maceration (P = 0.262). Overall, only the water-in-oil petrolatum- based product performed effectively within all the parameters tested. This study suggests that skin barrier protection involves more than the inclusion of an active barrier ingredient. Further testing and use of barrier products in the clinical setting will provide additional evidence for appropriate product selection.

  13. Two-week aerosol inhalation study on polyethylene glycol (PEG) 3350 in F-344 rats.

    PubMed

    Klonne, D R; Dodd, D E; Losco, P E; Troup, C M; Tyler, T R

    1989-03-01

    PEGs in the 3000 to 4000 MW range are used in many pharmaceutical and cosmetic applications; they produce little ocular or dermal irritation and have extremely low acute and subchronic toxicity by oral and dermal routes of administration. However, little information exists on the potential of aerosols of these materials to produce adverse health effects. F-344 rats were exposed to aerosols of PEG 3350 (20% w:w in water) at 0, 109, 567, or 1008 (highest attainable) mg/m3 for 6 hr/d, 5 d/wk for 2 wk. No exposure-related toxicity was found with regard to clinical signs, ophthalmology, serum chemistry, urinalysis, or gross pathology. Exposure-related effects included: a 50% increase in the neutrophil count (males only) at 1008 mg/m3; decreased body weight gain (16%) for both the 567 and 1008 mg/m3 groups (males only); absolute lung weights of both sexes were increased 10 and 18% for the 567 and 1008 mg/m3 groups, respectively. A slight increase in the number of macrophages in the alveoli was the only change observed histologically in all PEG 3350-exposed groups. Therefore, inhalation of aerosols of PEG 3350 at concentrations up to 1008 mg/m3 produced relatively little toxicity in rats, the lung was the target organ, and the no-observable-effect-level was between 109 to 567 mg/m3.

  14. CON4EI: EpiOcular™ Eye Irritation Test (EpiOcular™ EIT) for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Kandarova, H; Letasiova, S; Adriaens, E; Guest, R; Willoughby, J A; Drzewiecka, A; Gruszka, K; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested. Copyright © 2017. Published by Elsevier Ltd.

  15. A Prototype Lip Balm: Summary of Three Dermatological Studies Demonstrating Safety and Acceptability for Sensitive Skin.

    PubMed

    Nisbet, Stephanie

    Data were generated from three studies to assess the tolerability and acceptability of a prototype cosmetic lip balm. Dermatological assessments of topical compatibility (primary and cumulative irritability and sensitization), photoirritant and topical photosensitizer potential, and acceptability for safe use of a prototype cosmetic lip balm on sensitive skin are summarized. In Study 1, the product was applied to the volunteers' backs under a semiocclusive patch followed by patch removal/reapplication over 6 weeks to assess the irritant and allergic potential of the product. Dermatological assessments were performed at the beginning and end of the study or when there was evidence of positivity or adverse event. Study 2 was conducted by applying the product to the volunteers' backs under a semiocclusive patch, followed by patch removal/reapplication and irradiation of the test area with ultraviolet A (UVA) radiation at various intervals over 5 weeks. Dermatological assessments were performed to assess the product's role in the induction of photoirritancy and photosensitization. Clinical and subjective assessments for acceptability were obtained during Study 3 in volunteers with a diagnosis of sensitive skin and those who used the product as per instructions for use during the study period. The data generated from the three studies demonstrated no evidence of primary or cumulative dermal irritation or of dermal sensitization. In addition, no photoirritation potential or photosensitization potential was observed. As assessed by dermatologic monitoring and subject diary entries, the prototype lip balm did not cause irritation or sensitization reactions when used for 28 days in volunteers with a diagnosis of sensitive skin. Based on these findings, the prototype lip balm can be considered suitable for use for people with sensitive skin.

  16. Histological Characterization of the Irritative Zones in Focal Cortical Dysplasia Using a Preclinical Rat Model.

    PubMed

    Deshmukh, Abhay; Leichner, Jared; Bae, Jihye; Song, Yinchen; Valdés-Hernández, Pedro A; Lin, Wei-Chiang; Riera, Jorge J

    2018-01-01

    Current clinical practice in focal epilepsy involves brain source imaging (BSI) to localize brain areas where from interictal epileptiform discharges (IEDs) emerge. These areas, named irritative zones , have been useful to define candidate seizures-onset zones during pre-surgical workup. Since human histological data are mostly available from final resected zones, systematic studies characterizing pathophysiological mechanisms and abnormal molecular/cellular substrates in irritative zones-independent of them being epileptogenic-are challenging. Combining BSI and histological analysis from all types of irritative zones is only possible through the use of preclinical animal models. Here, we recorded 32-channel spontaneous electroencephalographic data from rats that have focal cortical dysplasia (FCD) and chronic seizures. BSI for different IED subtypes was performed using the methodology presented in Bae et al. (2015). Post-mortem brain sections containing irritative zones were stained to quantify anatomical, functional, and inflammatory biomarkers specific for epileptogenesis, and the results were compared with those obtained using the contralateral healthy brain tissue. We found abnormal anatomical structures in all irritative zones (i.e., larger neuronal processes, glioreactivity, and vascular cuffing) and larger expressions for neurotransmission (i.e., NR2B) and inflammation (i.e., ILβ1, TNFα and HMGB1). We conclude that irritative zones in this rat preclinical model of FCD comprise abnormal tissues disregarding whether they are actually involved in icto-genesis or not. We hypothesize that seizure perpetuation happens gradually; hence, our results could support the use of IED-based BSI for the early diagnosis and preventive treatment of potential epileptic foci. Further verifications in humans are yet needed.

  17. Evaluating tretinoin formulations in the treatment of acne.

    PubMed

    Kircik, Leon H

    2014-04-01

    Topical tretinoin has been a standard treatment for acne vulgaris for more than 4 decades. While tretinoin has demonstrated proven efficacy in the treatment of acne lesions, it also is associated with the potential for skin irritation. Newer formulations have been designed to optimize both the drug concentration and the delivery vehicle with the aim to enable clinicians to provide increasingly effective acne treatment that minimizes irritation. These therapies include formulations with varying concentrations of tretinoin and vehicles that utilize a microsponge delivery system, hydrogels and micronized tretinoin, or propolymers. The purpose of this review is to evaluate different formulations and combinations of tretinoin in the treatment of acne vulgaris. While these advanced formulations were designed for controlled release of active ingredient, and have the potential to reduce cutaneous irritation relative to standard tretinoin cream and gel formulations, there is a need for comparative studies to evaluate the relative benefits of each of these advanced tretinoin formulations in optimizing acne treatment.

  18. Alp Rose stem cells, olive oil squalene and a natural alkyl polyglucoside emulsifier: Are they appropriate ingredients of skin moisturizers - in vivo efficacy on normal and sodium lauryl sulfate - irritated skin?.

    PubMed

    Filipović, Mila; Gledović, Ana; Lukić, Milica; Tasić-Kostov, Marija; Isailović, Tanja; Pantelić, Ivana; Vuleta, Gordana; Savić, Snežana

    2016-11-01

    Since skin moisturization may be achieved by both actives and chosen carrier, plant stem cells, squalene and natural alkyl polyglucoside emulsifier may be potential components of contemporary cosmetic products. The aim of the study was in vivo evaluation of the skin irritation potential and the efficacy of Alpine Rose stem cells incorporated into li-posomes and olive oil squalene as ingredients of moisturizing creams, with respect to the novel emulsifier used for creams’ stabilization. With the employment of noninvasive skin biophysical measurements, skin hydration (EC), transepi-dermal water loss (TEWL), erythema index (EI) and viscoelas-ticity were measured on 76 healthy volunteers. In the first phase, skin irritation after a 24-hour occlusion and the long-term efficacy of creams (a 21-day study) on healthy skin were evaluated. Phase II of the study focused on the cream efficacy assessment after a 6-day treatment of sodium lauryl sulfate-irritated skin. After a 24-hour occlusion, there were no significant changes in the EI for any tested sample. In the second phase of the study, the EI was not significantly altered for the cream containing squalene, while the application of all active samples resulted in a significant reduction of TEWL. In both phases of the study an EC increase was recorded, espe-cially for the squalene-containing cream. Due to the lack of skin irritation and skin barrier impairment along with the marked hydration effect, it could be said that the in-vestigated actives incorporated into alkyl polyglucoside emulsi-fier-stabilized creams may be safely applied as ingredients for "tailor-made" cosmetic moisturizers intended for normal and dry skin care, whereas olive oil squalene could be used for the treatment of irritated or sensitive skin as well. [Projekat Ministarstva nauke Republike Srbije, br. TR34031

  19. IN VIVO EVALUATION OF SKIN IRRITATION POTENTIAL, MELASMA AND SEBUM CONTENT FOLLOWING LONG TERM APPLICATION OF SKIN CARE CREAM IN HEALTHY ADULTS, USING NON-INVASIVE BIOMETROLOGICAL TECHNIQUES.

    PubMed

    Arshad, Atif I; Khan, Shoaib H M; Akhtar, Naveed; Mahmood, Asif; Sarfraz, Rai Muhammad

    2016-01-01

    The present investigation was conducted to evaluate non-invasively, various functional skin parameters i.e., irritation potential, melasma and sebum contents following long term application of topical cream (w/o) loaded with 2% methanolic extract of Ananas comosus L. versus placebo control (base) in healthy adults. Healthy human volunteers (n = 11, aged 20-30 years) were recruited for investigation and written informed consent was taken from each volunteer. In this single blinded study every volunteer applied formulation on one side of face and placebo on the other side of face twice daily for a period of 12 weeks (three months). Different skin parameters i.e., skin irritancy, melasma, and sebum contents were measured on both sides of face at baseline and after two weeks interval, using photometric device Mexameter and Sebumeter in a draught free room with modulated conditions of temperature (22-25°C) and humidity (55-60%). It was evident from the results that no primary skin irritancy was observed with patch test. Besides, statistical interpretation indicates that treatment with formulation is superior to placebo because it significantly (p ≤ 0.05) reduced the skin irritancy, melasma and sebum secretions throughout the study and reaching maximum -20.76 ± 0.89, -54.2 ± 0.37 and -40.71 ± 0.75%, respectively, at the end of study period. Antioxidant activity of extract was 92% compared to standard antioxidant. Conclusively, active cream loaded with fruit extract was well tolerated by all the volunteers and suitable to treat contact dermatitis, greasy skin, acne and seborrheic dermatitis and augmenting beauty and attraction by depigmentation of human skin. So, in the future, there is need to clinically evaluate these formulations in patients with compromised skin functions i.e., contact dermatitis, melasma, and acne vulgaris in order to explore the actual potential of this fruit.

  20. Control of Cross Talk between Angiogenesis and Inflammation by Mesenchymal Stem Cells for the Treatment of Ocular Surface Diseases.

    PubMed

    Li, Fei; Zhao, Shao-Zhen

    2016-01-01

    Angiogenesis is beneficial in the treatment of ischemic heart disease and peripheral artery disease. However, it facilitates inflammatory cell filtration and inflammation cascade that disrupt the immune and angiogenesis privilege of the avascular cornea, resulting in ocular surface diseases and even vision loss. Although great progress has been achieved, healing of severe ocular surface injury and immunosuppression of corneal transplantation are the most difficult and challenging step in the treatment of ocular surface disorders. Mesenchymal stem cells (MSCs), derived from various adult tissues, are able to differentiate into different cell types such as endothelial cells and fat cells. Although it is still under debate whether MSCs could give rise to functional corneal cells, recent results from different study groups showed that MSCs could improve corneal disease recovery through suppression of inflammation and modulation of immune cells. Thus, MSCs could become a promising tool for ocular surface disorders. In this review, we discussed how angiogenesis and inflammation are orchestrated in the pathogenesis of ocular surface disease. We overviewed and updated the knowledge of MSCs and then summarized the therapeutic potential of MSCs via control of angiogenesis, inflammation, and immune response in the treatment of ocular surface disease.

  1. Genome-Wide Association Study of Entropion Eyelid in Multiple Breeds of Sheep

    USDA-ARS?s Scientific Manuscript database

    Entropion is an inversion of the eyelid margin causing lashes or external hairs to rub against the ocular surface. If uncorrected, discomfort, ocular damage, increased eye infection rates, and potential blindness can occur. Entropion affects many mammalian species, can be expressed in both upper and...

  2. Nanotherapies for the treatment of ocular diseases.

    PubMed

    Reimondez-Troitiño, S; Csaba, N; Alonso, M J; de la Fuente, M

    2015-09-01

    The topical route is the most frequent and preferred way to deliver drugs to the eye. Unfortunately, the very low ocular drug bioavailability (less than 5%) associated with this modality of administration, makes the efficient treatment of several ocular diseases a significant challenge. In the last decades, it has been shown that specific nanocarriers can interact with the ocular mucosa, thereby increasing the retention time of the associated drug onto the eye, as well as its permeability across the corneal and conjunctival epithelium. In this review, we comparatively analyze the mechanism of action and specific potential of the most studied nano-drug delivery carriers. In addition, we present the success achieved until now using a number of nanotherapies for the treatment of the most prevalent ocular pathologies, such as infections, inflammation, dry eye, glaucoma, and retinopathies. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Gelucire44/14 as a novel absorption enhancer for drugs with different hydrophilicities: in vitro and in vivo improvement on transcorneal permeation.

    PubMed

    Liu, Rui; Liu, Zhidong; Zhang, Chengui; Zhang, Boli

    2011-08-01

    The objective of this study was to investigate the application of Gelucire44/14 as a novel absorption enhancer in ophthalmic drug delivery system. Six compounds, namely ribavirin, puerarin, mangiferin, berberin hydrochloride, baicalin, and curcumin in the order of increasing lipophilicity were selected as model drugs. The effect of Gelucire44/14 on transcorneal permeation was evaluated across excised rabbit cornea. Ocular irritation and precorneal retention time were assessed. Additionally, aqueous humor pharmacokinetic test was performed by microdialysis. The results indicated that Gelucire44/14, at a concentration of 0.05% or 0.1% (w/v), was found to maximally increase the apparent permeability coefficient by 6.47-, 4.14-, 3.50-, 3.97-, 2.92-, and 1.86-fold for ribavirin, puerarin, mangiferin, berberin hydrochloride, baicalin, and curcumin, respectively (p < 0.05). Moreover, Gelucire44/14 was nonirritant at broad concentrations of 0.025%-0.4% (w/v). Pharmacokinetic tests showed that Gelucire44/14 promoted ocular bioavailability of the compounds as indicated by 5.40-, 4.03-, 3.46-, 3.57-, 2.77-, and 1.77-fold maximal increase in the area under the curve for the drugs aforementioned, respectively (p < 0.01). Therefore, Gelucire44/14 exerted a significant improvement on the permeation of both hydrophilic and lipophilic compounds, especially hydrophilic ones. Hence, Gelucire44/14 can be considered as a safe and effective absorption enhancer for ophthalmic drug delivery system. Copyright © 2011 Wiley-Liss, Inc.

  4. Multidose Preservative Free Eyedrops by Selective Removal of Benzalkonium Chloride from Ocular Formulations.

    PubMed

    Hsu, Kuan-Hui; Gupta, Karishma; Nayaka, Harish; Donthi, Aashrit; Kaul, Siddarth; Chauhan, Anuj

    2017-12-01

    About 70% of eye drops contain benzalkonium chloride (BAK) to maintain sterility. BAK is an effective preservative but it can cause irritation and toxicity. We propose to mitigate ocular toxicity without compromising sterility by incorporating a filter into an eye drop bottle to selectively remove BAK during the process of drop instillation. The filter is a packed bed of particles made from poly(2-hydroxyethyl methacrylate) (pHEMA), which is a common ophthalmic material. We showed that pHEMA particle prepared by using ethoxylated trimethylolpropane triacrylate as crosslinker can be incorporated into a modified eyedrop bottle tip to selectively remove the preservative as the formulation is squeezed out of the bottle. Hydraulic permeability of the plug is measured to determine the resistance to eye drop squeezing, and % removal of BAK and drugs are determined. The modified tip has a hydraulic permeability of about 2 Darcy, which allows eyedrops formulations to flow through without excessive resistance. The tip is designed such that the patients can create an eyedrop of solution of 1-10 cP viscosity in 4 s with a nominal pressure. During this short contact time, the packed particles removed nearly 100% of benzalkonium chloride (BAK) from a 15 mL, 0.012% BAK solution but have only minimal impact on the concentration of contained active components. Our novel design can eliminate the preservative induced toxicity from eye drops thereby impacting hundreds of millions of patients with chronic ophthalmic diseases like glaucoma and dry eyes.

  5. On-eye breakage and recovery of mini-scleral contact lens without compromise for the ocular surface.

    PubMed

    Macedo-de-Araújo, Rute J; van der Worp, Eef; González-Méijome, José M

    2018-06-01

    To report the on-eye breakage of a mini-scleral contact lens in a healthy cornea after being hit by a speeding object, without causing any severe corneal damage. A 24-year-old Caucasian male involved in a clinical study reported the in situ breakage of a mini-scleral contact lens during motorbike maintenance. The patient reported eye redness and irritation that significantly decreased after all the pieces of the lens were recovered from the eye. Ocular examinations within 48 h showed absence of corneal damage other than superficial punctate keratitis inferiorly and no fragments of the lens were found in the conjunctival sac. The patient was wearing a 15.2 mm mini-scleral lens in a high Dk material. The evolution of rigid materials towards higher Dk values has resulted in a decreased hardness and modulus values, so these materials are more elastic when subjected to mechanical stress, which could be a beneficial aspect in absorbing the energy of an impact before breaking in pieces. This case report shows that ScCL could have a protective effect to the corneal surface from the direct impact of a high-speed object. Mechanical material properties, wide supporting area and post-lens tear volume acted as protective factors helping to absorb and distribute the kinetic energy of the impacting object. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Müller glia-derived PRSS56 is required to sustain ocular axial growth and prevent refractive error.

    PubMed

    Paylakhi, Seyyedhassan; Labelle-Dumais, Cassandre; Tolman, Nicholas G; Sellarole, Michael A; Seymens, Yusef; Saunders, Joseph; Lakosha, Hesham; deVries, Wilhelmine N; Orr, Andrew C; Topilko, Piotr; John, Simon Wm; Nair, K Saidas

    2018-03-01

    A mismatch between optical power and ocular axial length results in refractive errors. Uncorrected refractive errors constitute the most common cause of vision loss and second leading cause of blindness worldwide. Although the retina is known to play a critical role in regulating ocular growth and refractive development, the precise factors and mechanisms involved are poorly defined. We have previously identified a role for the secreted serine protease PRSS56 in ocular size determination and PRSS56 variants have been implicated in the etiology of both hyperopia and myopia, highlighting its importance in refractive development. Here, we use a combination of genetic mouse models to demonstrate that Prss56 mutations leading to reduced ocular size and hyperopia act via a loss of function mechanism. Using a conditional gene targeting strategy, we show that PRSS56 derived from Müller glia contributes to ocular growth, implicating a new retinal cell type in ocular size determination. Importantly, we demonstrate that persistent activity of PRSS56 is required during distinct developmental stages spanning the pre- and post-eye opening periods to ensure optimal ocular growth. Thus, our mouse data provide evidence for the existence of a molecule contributing to both the prenatal and postnatal stages of human ocular growth. Finally, we demonstrate that genetic inactivation of Prss56 rescues axial elongation in a mouse model of myopia caused by a null mutation in Egr1. Overall, our findings identify PRSS56 as a potential therapeutic target for modulating ocular growth aimed at preventing or slowing down myopia, which is reaching epidemic proportions.

  7. Müller glia-derived PRSS56 is required to sustain ocular axial growth and prevent refractive error

    PubMed Central

    Tolman, Nicholas G; Sellarole, Michael A.; Saunders, Joseph; Lakosha, Hesham; Topilko, Piotr; John, Simon WM.

    2018-01-01

    A mismatch between optical power and ocular axial length results in refractive errors. Uncorrected refractive errors constitute the most common cause of vision loss and second leading cause of blindness worldwide. Although the retina is known to play a critical role in regulating ocular growth and refractive development, the precise factors and mechanisms involved are poorly defined. We have previously identified a role for the secreted serine protease PRSS56 in ocular size determination and PRSS56 variants have been implicated in the etiology of both hyperopia and myopia, highlighting its importance in refractive development. Here, we use a combination of genetic mouse models to demonstrate that Prss56 mutations leading to reduced ocular size and hyperopia act via a loss of function mechanism. Using a conditional gene targeting strategy, we show that PRSS56 derived from Müller glia contributes to ocular growth, implicating a new retinal cell type in ocular size determination. Importantly, we demonstrate that persistent activity of PRSS56 is required during distinct developmental stages spanning the pre- and post-eye opening periods to ensure optimal ocular growth. Thus, our mouse data provide evidence for the existence of a molecule contributing to both the prenatal and postnatal stages of human ocular growth. Finally, we demonstrate that genetic inactivation of Prss56 rescues axial elongation in a mouse model of myopia caused by a null mutation in Egr1. Overall, our findings identify PRSS56 as a potential therapeutic target for modulating ocular growth aimed at preventing or slowing down myopia, which is reaching epidemic proportions. PMID:29529029

  8. A Marine Hazardous Substances Data System. Volume 2.

    DTIC Science & Technology

    1985-12-01

    substances are considered by the Task III panel ill to exhibit the greatest potential for occupational health effects and warrant the greatest precautions for...Hazards Branch 1111 N NIOSH Registry of Toxic Effects of Chemical Substances 1121 P NIOSH/OSHA Pocket Guideto Chemical Hazards [61 U Undocumented Source...NAS Hazard Liquid or -- Rating Vapor Irritant Solid Irritant Poisons 0 No effect No effect No effect 1 Slight Effect Causes skin Slightly toxic

  9. [Grade IIb alkali burns of the lower extremities. Working with concrete].

    PubMed

    Hasenecker, J M H; Ruchholtz, S; Eming, R; Frangen, T M

    2014-01-01

    The irritating effects of concrete (calcium oxide) on skin have long been known. The effect by long-term skin exposure is not only irritating but also erosive and alkali skin erosion may result due to colliquative skin necrosis. A complicated course may ensue potentially necessitating plastic reconstructive treatment due to the development of unstable scars and defects. Correct interpretation of the skin trauma and adequate treatment are mandatory for functional restitution.

  10. Avoidance Behavior to Essential Oils by Anopheles minimus, a Malaria Vector in Thailand.

    PubMed

    Nararak, Jirod; Sathantriphop, Sunaiyana; Chauhan, Kamal; Tantakom, Siripun; Eiden, Amanda L; Chareonviriyaphap, Theeraphap

    2016-03-01

    Essential oils extracted from 4 different plant species--citronella (Cymbopogon nardus), hairy basil (Ocimum americanum), sweet basil (Ocimum basilicum), and vetiver (Vetiveria zizanioides)-were investigated for their irritant and repellent activities against Anopheles minimus, using an excito-repellency test system. Pure essential oils were used in absolute ethanol at the concentrations of 0.5%, 1%, 2.5%, and 5% (v/v) compared with deet. At the lowest concentration of 0.5%, hairy basil displayed the best irritant and repellent effects against An. minimus. Citronella and vetiver at 1-5% showed strong irritant effects with>80% escape, while repellent effects of both oils were observed at 1% and 2.5% citronella (73-89% escape) and at 5% vetiver (83.9% escape). Sweet basil had only moderate irritant action at 5% concentration (69.6% escape) and slightly repellent on test mosquitoes (<50% escape). The results found that hairy basil, citronella, and vetiver are promising potential mosquito repellent products for protection against An. minimus.

  11. DERMATOLOGIC CHANGES IN THE CIRCUMILEOSTOMY SKIN

    PubMed Central

    McNamara, Robert J.; Farber, Eugene M.; Roland, Samuel I.

    1959-01-01

    A comprehensive questionnaire inquiring about difficulties with care of the skin in the area immediately surrounding the artificial anus was sent to ileostomy patients in the United States. Eighty per cent of 327 replying to the questionnaire had such difficulties. The problem of irritation is essentially that of intimate contact of fecal material with the circumileostomy skin, and associated factors are the potentially irritating materials used in the manufacture of ileostomy appliances, as well as the adhesives used to affix the appliance to the skin. Mechanical trauma incident to removal and reapplication of the appliance, as well as loosening of the disc and exposure of unprotected skin, accelerates the corrosive action of the material discharged. Changing the appliance before leakage or irritation occurs is helpful in preventing skin difficulties. In cases of long standing or repeated irritation, care must be taken to check the suitability of the appliance or the possibility of a complication in the stoma that could be corrected surgically. ImagesFigure 2.Figure 4. PMID:13662859

  12. The prevalence of ocular diseases in polish Arabian horses.

    PubMed

    Paschalis-Trela, Katarzyna; Cywińska, Anna; Trela, Jan; Czopowicz, Michał; Kita, Jerzy; Witkowski, Lucjan

    2017-11-07

    Equine ocular diseases pose a medical challenge due to long-lasting and cost-consuming therapies as well as economic issues associated with potential decrease in value of affected horses. The scale of the problem is significant but difficult to precisely define because epidemiological data is limited and lacks consistency in presentation. To date, no retrospective studies specifically investigating Arabian horses have been published. The aim of this cross-sectional study was to investigate the prevalence of ocular lesions and define the ocular diseases present in Arabian horses from breeding farms in Poland. Clinical and ophthalmic examination of 615 Arabian horses at Polish breeding farms (15% of Arabian population in Poland) were performed and medical history from the previous 5 years was analyzed. Data was obtained from review of veterinary archives and epidemiological interview of the resident veterinarian at each farm. The prevalence of ocular diseases was 9.75%. The following pathologies were diagnosed (with their respective prevalence): equine recurrent uveitis (ERU; 5.5%); cataract not related to ERU (3.3%); non-visual eyes (1.13%); posttraumatic lesions (0.8%); glaucoma (0.16%). In this study, ERU was the most common ocular disease identified in Arabian horses in Poland. Its prevalence was lower than usually reported in Europe and the United States. There was no sex or farm predisposition but ocular disease prevalence increased with age. Other severe ocular pathologies were also observed, confirming that ocular diseases remain an important clinical problem.

  13. Ocular static and dynamic light scattering: a noninvasive diagnostic tool for eye research and clinical practice

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.

    2004-01-01

    The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

  14. Ocular toxicity of fludarabine

    PubMed Central

    Ding, Xiaoyan; Herzlich, Alexandra A; Bishop, Rachel; Tuo, Jingsheng; Chan, Chi-Chao

    2008-01-01

    The purine analogs, fludarabine and cladribine represent an important class of chemotherapy agents used to treat a broad spectrum of lymphoid malignancies. Their toxicity profiles include dose-limiting myelosuppression, immunosuppression, opportunistic infection and severe neurotoxicity. This review summarizes the neurotoxicity of high- and standard-dose fludarabine, focusing on the clinical and pathological manifestations in the eye. The mechanisms of ocular toxicity are probably multifactorial. With increasing clinical use, an awareness of the neurological and ocular vulnerability, particularly to fludarabine, is important owing to the potential for life- and sight-threatening consequences. PMID:18461151

  15. Chemotherapy Extravasation: Establishing a National Benchmark for Incidence Among Cancer Centers.

    PubMed

    Jackson-Rose, Jeannette; Del Monte, Judith; Groman, Adrienne; Dial, Linda S; Atwell, Leah; Graham, Judy; O'Neil Semler, Rosemary; O'Sullivan, Maryellen; Truini-Pittman, Lisa; Cunningham, Terri A; Roman-Fischetti, Lisa; Costantinou, Eileen; Rimkus, Chris; Banavage, Adrienne J; Dietz, Barbara; Colussi, Carol J; Catania, Kimberly; Wasko, Michelle; Schreffler, Kevin A; West, Colleen; Siefert, Mary Lou; Rice, Robert David

    2017-08-01

    Given the high-risk nature and nurse sensitivity of chemotherapy infusion and extravasation prevention, as well as the absence of an industry benchmark, a group of nurses studied oncology-specific nursing-sensitive indicators. 
. The purpose was to establish a benchmark for the incidence of chemotherapy extravasation with vesicants, irritants, and irritants with vesicant potential.
. Infusions with actual or suspected extravasations of vesicant and irritant chemotherapies were evaluated. Extravasation events were reviewed by type of agent, occurrence by drug category, route of administration, level of harm, follow-up, and patient referrals to surgical consultation.
. A total of 739,812 infusions were evaluated, with 673 extravasation events identified. Incidence for all extravasation events was 0.09%.

  16. A survey on computer aided diagnosis for ocular diseases

    PubMed Central

    2014-01-01

    Background Computer Aided Diagnosis (CAD), which can automate the detection process for ocular diseases, has attracted extensive attention from clinicians and researchers alike. It not only alleviates the burden on the clinicians by providing objective opinion with valuable insights, but also offers early detection and easy access for patients. Method We review ocular CAD methodologies for various data types. For each data type, we investigate the databases and the algorithms to detect different ocular diseases. Their advantages and shortcomings are analyzed and discussed. Result We have studied three types of data (i.e., clinical, genetic and imaging) that have been commonly used in existing methods for CAD. The recent developments in methods used in CAD of ocular diseases (such as Diabetic Retinopathy, Glaucoma, Age-related Macular Degeneration and Pathological Myopia) are investigated and summarized comprehensively. Conclusion While CAD for ocular diseases has shown considerable progress over the past years, the clinical importance of fully automatic CAD systems which are able to embed clinical knowledge and integrate heterogeneous data sources still show great potential for future breakthrough. PMID:25175552

  17. JBP485 promotes tear and mucin secretion in ocular surface epithelia

    PubMed Central

    Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru

    2015-01-01

    Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES. PMID:25996902

  18. JBP485 promotes tear and mucin secretion in ocular surface epithelia.

    PubMed

    Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru

    2015-05-21

    Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES.

  19. Biological Evaluation of the Copper/Low-density Polyethylene Nanocomposite Intrauterine Device

    PubMed Central

    Wang, Hong; Li, Jun; Xie, Changsheng; Duan, Zhuo; Sun, Li-Kui; Wang, Xin; Zhu, Changhong

    2013-01-01

    Devices and materials intended for clinical applications as medical and implant devices should be evaluated to determine their biocompatibility in physiological systems. This article presents results from cytotoxicity assay of L929 mouse fibroblasts culture, tests for skin irritation, intracutaneous reactivity and sensitization, and material implantation tests for the novel copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD) with potential for future clinical utilization. Cytotoxicity test in vitro was conducted to evaluate the change in morphology, growth and proliferation of cultured L929 mouse fibroblasts, which in vivo examination for skin irritation (n = 6) and intracutaneous reactivity (n = 6) were carried out to explore the irritant behavior in New Zealand White rabbits. Skin sensitization was implemented to evaluate the potential skin sensitizing in Hartley guinea pigs (n = 35). The materials were implanted into the spinal muscle of rabbits (n = 9). The cytotoxicity grade of the nano-Cu/LDPE IUD was 0–1, suggested that the composite was nontoxic or mildly cytotoxic; no irritation reaction and skin sensitization were identified in any animals of specific extracts prepared from the material under test; similarly to the control sides, the inflammatory reaction was observed in the rabbits living tissue of the implanted material in intramuscular implantation assay. They indicated that the novel composite intrauterine device presented potential for this type of application because they meet the requirements of the standard practices recommended for evaluating the biological reactivity. The nano-Cu/LDPE IUD has good biocompatibility, which is biologically safe for the clinical research as a novel contraceptive device. PMID:24058521

  20. Biological evaluation of the copper/low-density polyethylene nanocomposite intrauterine device.

    PubMed

    Hu, Li-Xia; He, Jing; Hou, Li; Wang, Hong; Li, Jun; Xie, Changsheng; Duan, Zhuo; Sun, Li-Kui; Wang, Xin; Zhu, Changhong

    2013-01-01

    Devices and materials intended for clinical applications as medical and implant devices should be evaluated to determine their biocompatibility in physiological systems. This article presents results from cytotoxicity assay of L929 mouse fibroblasts culture, tests for skin irritation, intracutaneous reactivity and sensitization, and material implantation tests for the novel copper/low-density polyethylene nanocomposite intrauterine device (nano-Cu/LDPE IUD) with potential for future clinical utilization. Cytotoxicity test in vitro was conducted to evaluate the change in morphology, growth and proliferation of cultured L929 mouse fibroblasts, which in vivo examination for skin irritation (n = 6) and intracutaneous reactivity (n = 6) were carried out to explore the irritant behavior in New Zealand White rabbits. Skin sensitization was implemented to evaluate the potential skin sensitizing in Hartley guinea pigs (n = 35). The materials were implanted into the spinal muscle of rabbits (n = 9). The cytotoxicity grade of the nano-Cu/LDPE IUD was 0-1, suggested that the composite was nontoxic or mildly cytotoxic; no irritation reaction and skin sensitization were identified in any animals of specific extracts prepared from the material under test; similarly to the control sides, the inflammatory reaction was observed in the rabbits living tissue of the implanted material in intramuscular implantation assay. They indicated that the novel composite intrauterine device presented potential for this type of application because they meet the requirements of the standard practices recommended for evaluating the biological reactivity. The nano-Cu/LDPE IUD has good biocompatibility, which is biologically safe for the clinical research as a novel contraceptive device.

  1. Occlusion of retinal capillaries caused by glial cell proliferation in chronic ocular inflammation.

    PubMed

    Bianchi, E; Ripandelli, G; Feher, J; Plateroti, A M; Plateroti, R; Kovacs, I; Plateroti, P; Taurone, S; Artico, M

    2015-01-01

    The inner blood-retinal barrier is a gliovascular unit in which glial cells surround capillary endothelial cells and regulate retinal capillaries by paracrine interactions. During chronic ocular inflammation, microvascular complications can give rise to vascular proliferative lesions, which compromise visual acuity. This pathologic remodelling caused by proliferating Müller cells determines occlusion of retinal capillaries. The aim of the present study was to identify qualitative and quantitative alterations in the retinal capillaries in patients with post-traumatic chronic ocular inflammation or post-thrombotic vascular glaucoma. Moreover, we investigated the potential role of vascular endothelial growth factor (VEGF) and pro-inflammatory cytokines in retinal inflammation. Our electron microscopy findings demonstrated that during chronic ocular inflammation, thickening of the basement membrane, loss of pericytes and endothelial cells and proliferation of Müller cells occur with irreversible occlusion of retinal capillaries. Angiogenesis takes place as part of a regenerative reaction that results in fibrosis. We believe that VEGF and pro-inflammatory cytokines may be potential therapeutic targets in the treatment of this disease although further studies are required to confirm these findings.

  2. Emerging role of aripiprazole for treatment of irritability associated with autistic disorder in children and adolescents.

    PubMed

    Stachnik, Joan; Gabay, Michael

    2010-01-01

    Autistic disorder is a largely misunderstood and difficult to treat neurodevelopmental disorder. Three core domains of functioning are affected by autistic disorder, ie, socialization, communication, and behavior. Signs of autistic disorder may be present early, but are frequently overlooked, resulting in a delay in its diagnosis and a subsequent delay in treatment. No one definitive therapy is available, and treatment consists of early educational and behavioral interventions, as well as drug therapy. Atypical antipsychotics have often been used in the treatment of autistic disorder to target irritability, aggression, and self-injurious behavior, all of which can interfere with other aspects of treatment. One atypical antipsychotic, aripiprazole, has recently been approved for treatment of irritability associated with autistic disorder. Based on the results from two randomized, controlled trials, with efficacy data from nearly 300 patients, treatment with aripiprazole was associated with reductions in irritability, global improvements in behavior, and improvements in quality of life from both the patient and caregiver perspectives. Dosage of aripiprazole ranged from 5 mg to 15 mg per day. Aripiprazole was well tolerated during clinical trials, with most adverse events considered mild or moderate. Clinically relevant weight gain occurred in about 30% of patients given aripiprazole, although when compared with other atypical antipsychotics, aripiprazole appears to have fewer metabolic effects and a lower risk of weight gain. However, pediatric patients taking any atypical antipsychotic should be carefully monitored for potential adverse events, because the long-term effects of antipsychotic therapy in this population are not well known. When used appropriately, aripiprazole has the potential to be an effective treatment for children with autistic disorder to improve irritability and aggressive behavior and improve quality of life.

  3. Emerging role of aripiprazole for treatment of irritability associated with autistic disorder in children and adolescents

    PubMed Central

    Stachnik, Joan; Gabay, Michael

    2010-01-01

    Autistic disorder is a largely misunderstood and difficult to treat neurodevelopmental disorder. Three core domains of functioning are affected by autistic disorder, ie, socialization, communication, and behavior. Signs of autistic disorder may be present early, but are frequently overlooked, resulting in a delay in its diagnosis and a subsequent delay in treatment. No one definitive therapy is available, and treatment consists of early educational and behavioral interventions, as well as drug therapy. Atypical antipsychotics have often been used in the treatment of autistic disorder to target irritability, aggression, and self-injurious behavior, all of which can interfere with other aspects of treatment. One atypical antipsychotic, aripiprazole, has recently been approved for treatment of irritability associated with autistic disorder. Based on the results from two randomized, controlled trials, with efficacy data from nearly 300 patients, treatment with aripiprazole was associated with reductions in irritability, global improvements in behavior, and improvements in quality of life from both the patient and caregiver perspectives. Dosage of aripiprazole ranged from 5 mg to 15 mg per day. Aripiprazole was well tolerated during clinical trials, with most adverse events considered mild or moderate. Clinically relevant weight gain occurred in about 30% of patients given aripiprazole, although when compared with other atypical antipsychotics, aripiprazole appears to have fewer metabolic effects and a lower risk of weight gain. However, pediatric patients taking any atypical antipsychotic should be carefully monitored for potential adverse events, because the long-term effects of antipsychotic therapy in this population are not well known. When used appropriately, aripiprazole has the potential to be an effective treatment for children with autistic disorder to improve irritability and aggressive behavior and improve quality of life. PMID:24600266

  4. Assessment of test method variables for in vitro skin irritation testing of medical device extracts.

    PubMed

    Olsen, Daniel S; Lee, Michelle; Turley, Audrey P

    2018-08-01

    Skin irritation is an important component of the biological safety evaluation of medical devices. This testing has typically been performed using in vivo models. However, in an effort to reduce the need for in vivo testing, alternative methods for assessing skin irritation potential in vitro have been developed using a Reconstructed Human Epidermis (RhE) model. During the development of the protocol for the round robin validation of in vitro irritation testing for medical device extracts, it became clear that there were three points in the procedure where different options may be validated within each laboratory for routine testing: sample exposure time (18 vs 24h), SDS positive control concentration, and cytokine (IL-1α) release testing. The goal of our study was to evaluate the effect of these variables. EpiDerm™ tissues were exposed to extracts of three plain polymer samples, and four polymers embedded with known irritant chemicals. Exposures were performed for 18 and 24h. Resulting tissue viability was assessed by MTT reduction and IL-1α release was assessed by ELISA. Testing was also performed using various concentrations of SDS ranging from 0.5 to 1% (w/v). Overall, results were similar for samples tested and 18 and 24h, but the 18h exposure time has the potential to have an impact on the results of some sample types. IL-1α testing was shown to be useful to clarify conflicting tissue viability results. Use of a lower concentration of SDS as a positive control can help prevent issues that arise from excessive tissue damage often caused by 1% SDS. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Larvicidal and irritant activities of hexane leaf extracts of Citrus sinensis against dengue vector Aedes aegypti L.

    PubMed

    Warikoo, Radhika; Ray, Ankita; Sandhu, Jasdeep Kaur; Samal, Roopa; Wahab, Naim; Kumar, Sarita

    2012-02-01

    To assess the larvicidal and irritant activities of the hexane extracts of leaves of Citrus sinensis (C. sinensis) against the early fourth instars and female adults of Aedes aegypti (Ae. aegypti). The larvicidal potential of the prepared leaf extract was evaluated against early fourth instar larvae of Ae. aegypti using WHO protocol. The mortality counts were made after 24 h and LC50 and LC90 values were calculated. The efficacy of extract as mosquito irritant was assessed by contact irritancy assays. Extract-impregnated paper was placed on a glass plate over which a perspex funnel with a hole on the top was kept inverted. Single female adult, 3-day old unfed/blood-fed, was released inside the funnel. After 3 min of acclimatization time, the time taken for the first take-off and total number of flights undertaken during 15 min were scored. The citrus leaf extracts from hexane possessed moderate larvicidal efficiency against dengue vector. The bioassays resulted in an LC50 and LC90 value of 446.84 and 1 370.96 ppm, respectively after 24 h of exposure. However, the extracts were proved to be remarkable irritant against adults Ae. aegypti, more pronounced effects being observed on blood-fed females than unfed females. The extract-impregnated paper was thus proved to be 7-11 times more irritable as compared with the control paper. The hexane extracts from C. sinensis leaves are proved to be reasonably larvicidal but remarkably irritant against dengue vector. Further studies are needed to identify the possible role of extract as adulticide, oviposition deterrent and ovicidal agent. The isolation of active ingredient from the extract could help in formulating strategies for mosquito control.

  6. Identifying an indoor air exposure limit for formaldehyde considering both irritation and cancer hazards

    PubMed Central

    Golden, Robert

    2011-01-01

    Formaldehyde is a well-studied chemical and effects from inhalation exposures have been extensively characterized in numerous controlled studies with human volunteers, including asthmatics and other sensitive individuals, which provide a rich database on exposure concentrations that can reliably produce the symptoms of sensory irritation. Although individuals can differ in their sensitivity to odor and eye irritation, the majority of authoritative reviews of the formaldehyde literature have concluded that an air concentration of 0.3 ppm will provide protection from eye irritation for virtually everyone. A weight of evidence-based formaldehyde exposure limit of 0.1 ppm (100 ppb) is recommended as an indoor air level for all individuals for odor detection and sensory irritation. It has recently been suggested by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP), and the US Environmental Protection Agency (US EPA) that formaldehyde is causally associated with nasopharyngeal cancer (NPC) and leukemia. This has led US EPA to conclude that irritation is not the most sensitive toxic endpoint and that carcinogenicity should dictate how to establish exposure limits for formaldehyde. In this review, a number of lines of reasoning and substantial scientific evidence are described and discussed, which leads to a conclusion that neither point of contact nor systemic effects of any type, including NPC or leukemia, are causally associated with exposure to formaldehyde. This conclusion supports the view that the equivocal epidemiology studies that suggest otherwise are almost certainly flawed by identified or yet to be unidentified confounding variables. Thus, this assessment concludes that a formaldehyde indoor air limit of 0.1 ppm should protect even particularly susceptible individuals from both irritation effects and any potential cancer hazard. PMID:21635194

  7. Mineral intake independent from gastric irritation or pica by cell-dehydrated rats.

    PubMed

    Constancio, Juliana; Pereira-Derderian, Daniela T B; Menani, José V; De Luca, Laurival A

    2011-10-24

    Gavage of 2 M NaCl (IG 2 M NaCl), a procedure to induce cell-dehydration-and water and 0.15 M NaCl intake in a two-bottle choice test-is also a potential gastric irritant. In this study, we assessed whether mineral intake induced by IG 2 M NaCl is associated with gastric irritation or production of pica in the rat. We first determined the amount of mineral solution (0.15 M NaCl, 0.15 M NaHCO3, 0.01 M KCl and 0.05 mM CaCl2) and water ingested in response to IG 2 M NaCl in a five-bottle test. Then, we used mineral solutions (0.01 M KCl and 0.15 M NaHCO3), whose intakes were significantly increased compared to controls, and water in three-bottle tests to test the gastric irritation hypothesis. The IG 2 M NaCl induced KCl and NaHCO3 intake that was not inhibited by gavage with gastric protectors Al(OH)3 or NaHCO3. IG 2 M NaCl or gavage of 0.6 N acetic acid induced mild irritation, hyperemia, of the glandular part of the stomach. A gavage of 50% ethanol induced strong irritation seen as pinpoint ulcerations. Neither ethanol nor acetic acid induced any fluid intake. Neither IG 2 M NaCl nor acetic acid induced kaolin intake, a marker of pica in laboratory rats. Ethanol did induce kaolin intake. These results suggest that IG 2 M NaCl induced a mineral fluid intake not selective for sodium and independent from gastric irritation or pica. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Larvicidal and irritant activities of hexane leaf extracts of Citrus sinensis against dengue vector Aedes aegypti L.

    PubMed Central

    Warikoo, Radhika; Ray, Ankita; Sandhu, Jasdeep Kaur; Samal, Roopa; Wahab, Naim; Kumar, Sarita

    2012-01-01

    Objective To assess the larvicidal and irritant activities of the hexane extracts of leaves of Citrus sinensis (C. sinensis) against the early fourth instars and female adults of Aedes aegypti (Ae. aegypti). Methods The larvicidal potential of the prepared leaf extract was evaluated against early fourth instar larvae of Ae. aegypti using WHO protocol. The mortality counts were made after 24 h and LC50 and LC90 values were calculated. The efficacy of extract as mosquito irritant was assessed by contact irritancy assays. Extract-impregnated paper was placed on a glass plate over which a perspex funnel with a hole on the top was kept inverted. Single female adult, 3-day old unfed/blood-fed, was released inside the funnel. After 3 min of acclimatization time, the time taken for the first take-off and total number of flights undertaken during 15 min were scored. Results The citrus leaf extracts from hexane possessed moderate larvicidal efficiency against dengue vector. The bioassays resulted in an LC50 and LC90 value of 446.84 and 1 370.96 ppm, respectively after 24 h of exposure. However, the extracts were proved to be remarkable irritant against adults Ae. aegypti, more pronounced effects being observed on blood-fed females than unfed females. The extract-impregnated paper was thus proved to be 7–11 times more irritable as compared with the control paper. Conclusions The hexane extracts from C. sinensis leaves are proved to be reasonably larvicidal but remarkably irritant against dengue vector. Further studies are needed to identify the possible role of extract as adulticide, oviposition deterrent and ovicidal agent. The isolation of active ingredient from the extract could help in formulating strategies for mosquito control. PMID:23569887

  9. Correlation between pH and irritant effect of cleansers marketed for dry skin.

    PubMed

    Baranda, Lourdes; González-Amaro, Roberto; Torres-Alvarez, Bertha; Alvarez, Carmen; Ramírez, Victoria

    2002-08-01

    Although it is important that dermatologists and the general population know the irritation potential of products marketed for dry skin used for body cleansing, this information is not usually available. To assess the irritative effect of different soaps and liquid cleansers recommended for sensitive skin. To study the correlation of the irritation effect of each substance with its pH and with the presence or absence of syndet in the product. Seventeen products marketed for dry skin and 12 common soaps used by the general population were studied. Fresh soap emulsions (8%) were applied to the volar side of the right forearm of 30 individuals with sensitive skin for 5 consecutive days using aluminum chambers. The appearance of irritation (erythema, scaling and fissures) was recorded, scored, and expressed in an Irritation index (IrIn). The pH of each solution was measured. Products with a low IrIn were White Dove (Dove, Lever Pond's, Toronto, Ontario, Canada), Dove Baby, Cetaphil (bar) (Cetaphil, Gulderma Lab., Forth Worth, TX, USA), Dove liquid cleanser for hands, Dove pink, and Aderma (Adenma, Pierre Fabre, Dermo-Cosmetique, Boulagne, France). Most corresponded to syndet products. Among the most used brand-name soap, Camay Classic (Camay, Procter & Gamble de Mexico, México, U.F.) had the lowest IrIn. Dove Baby was the only product with a neutral pH. A significant correlation between pH and the IrIn of cleansers was found (P < 0.006). Most products recommended for sensitive skin have a considerable irritation effect, which is related to the pH of the product. Better regulation of advertisement specifications including the pH level and type of cleanser contained is necessary for the majority of soaps and cleansers.

  10. Comparative Study of the Biological Activity of Allantoin and Aqueous Extract of the Comfrey Root.

    PubMed

    Savić, Vesna Lj; Nikolić, Vesna D; Arsić, Ivana A; Stanojević, Ljiljana P; Najman, Stevo J; Stojanović, Sanja; Mladenović-Ranisavljević, Ivana I

    2015-08-01

    This study investigates the biological activity of pure allantoin (PA) and aqueous extract of the comfrey (Symphytum officinale L.) root (AECR) standardized to the allantoin content. Cell viability and proliferation of epithelial (MDCK) and fibroblastic (L929) cell line were studied by using MTT test. Anti-irritant potential was determined by measuring electrical capacitance, erythema index (EI) and transepidermal water loss of artificially irritated skin of young healthy volunteers, 3 and 7 days after application of creams and gels with PA or AECR. Pure allantoin showed mild inhibitory effect on proliferation of both cell lines at concentrations 40 and 100 µg/ml, but more pronounced on MDCK cells. Aqueous extract of the comfrey root effect on cell proliferation in concentrations higher than 40 µg/ml was significantly stimulatory for L929 but inhibitory for MDCK cells. Pharmaceutical preparations that contained AECR showed better anti-irritant potential compared with PA. Creams showed better effect on hydration and EI compared with the gels that contained the same components. Our results indicate that the biological activity of the comfrey root extract cannot be attributed only to allantoin but is also likely the result of the interaction of different compounds present in AECR. Topical preparations that contain comfrey extract may have a great application in the treatment of skin irritation. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Measurement of cytotoxicity and irritancy potential of sugar-based surfactants on skin-related 3D models.

    PubMed

    Lu, Biao; Miao, Yong; Vigneron, Pascale; Chagnault, Vincent; Grand, Eric; Wadouachi, Anne; Postel, Denis; Pezron, Isabelle; Egles, Christophe; Vayssade, Muriel

    2017-04-01

    Sugar-based surfactants present surface-active properties and relatively low cytotoxicity. They are often considered as safe alternatives to currently used surfactants in cosmetic industries. In this study, four sugar-based surfactants, each with an eight carbon alkyl chain bound to a glucose or a maltose headgroup through an amide linkage, were synthesized and compared to two standard surfactants. The cytotoxic and irritant effects of surfactants were evaluated using two biologically relevant models: 3D dermal model (mouse fibroblasts embedded in collagen gel) and reconstituted human epidermis (RHE, multi-layered human keratinocytes). Results show that three synthesized surfactants possess lower cytotoxicity compared to standard surfactants as demonstrated in the 3D dermal model. Moreover, the IC50s of surfactants against the 3D dermal model are higher than IC50s obtained with the 2D dermal model (monolayer mouse fibroblasts). Both synthesized and standard surfactants show no irritant effects after 48h of topical application on RHE. Throughout the study, we demonstrate the difficulty to link the physico-chemical properties of surfactants and their cytotoxicity in complex models. More importantly, our data suggest that, prior to in vivo tests, a complete understanding of surfactant cytotoxicity or irritancy potential requires a combination of cellular and tissue models. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Predictive performance of the Vitrigel-eye irritancy test method using 118 chemicals.

    PubMed

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2016-08-01

    We recently developed a novel Vitrigel-eye irritancy test (EIT) method. The Vitrigel-EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time-dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel-EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel-EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false-negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false-positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO-1, a tight junction-associated protein and MUC1, a cell membrane-spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false-positive chemicals, suggesting that such false-positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel-EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel-EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd.

  13. From topical antidote against skin irritants to a novel counter-irritating and anti-inflammatory peptide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brodsky, Berta; Erlanger-Rosengarten, Avigail; Proscura, Elena

    2008-06-15

    The primary purpose of the present study was to investigate the mechanism of the counter-irritating activity of topical iodine against skin lesions induced by chemical and thermal stimuli. The hypothesis that iodine exerts its activity by inducing an endogenous anti-inflammatory factor was confirmed by exposing guinea pig skin to heat stimulus followed by topical iodine treatment and skin extraction. Injection of the extract into naive guinea pigs reduced heat-induced irritation by 69%. The protective factor, identified as a new nonapeptide (histone H2A 36-44, H-Lys-Gly-Asn-Tyr-Ala-Glu-Arg-Ileu-Ala-OH), caused reduction of 40% in irritation score in heat-exposed guinea pigs. The murine analog (H-Lys-Gly-His-Tyr-Ala-Glu-Arg-Val-Gly-OH, termedmore » IIIM1) reduced sulfur mustard (SM)-induced ear swelling at a dose-dependent bell-shape manner reaching peak activity of 1 mg/kg. Cultured keratinocytes transfected with the peptide were more resistant towards SM than the control cells. The peptide suppressed oxidative burst in activated neutrophils in a concentration-dependent manner. In addition, the peptide reduced glucose oxidase-induced skin edema in mice at a dose-dependent bell-shape manner. Apart from thermal and chemical-induced skin irritation this novel peptide might be of potential use in chronic dermal disorders such as psoriasis and pemphigus as well as non-dermal inflammatory diseases like multiple sclerosis, arthritis and colitis.« less

  14. Acute toxicity and primary irritancy of alkylalkanolamines.

    PubMed

    Ballantyne, B; Leung, H W

    1996-12-01

    The acute handling hazards of several alkylalkanolamines were determined by investigating their potential acute toxicity and primary irritancy. Materials studied were N-methylethanolamine (MEA), N, N, -dimethylethanolamine (DMEA), N, N, -dimethylisopropanolamine (DMIPA), N-methyldiethanolamine (MDEA), and tertbutyldiethanolamine (BDEA). All these alkylalkanolamines were of comparable acute peroral toxicity in the rat (LD50 range 1.48-2.83 ml/kg). By 24 h occluded epicutaneous contact in the rabbit, MEA, DMEA and DMIPA were of moderate acute percutaneous toxicity (LD50 range 1.13-2.0 ml/kg), MDEA was of slight acute percutaneous toxicity (LD50 male 9.85 ml/kg, female 10.90 ml/kg), and BDEA of intermediate toxicity (LD50 6.4 ml/kg). Due to differences in vapor pressure the acute vapor exposure toxicity of the alkylalkanolamines to rats varied; MEA, MDEA and BDEA were of a low order of acute toxicity, and DMIPA was moderately toxic with an LT50 of 3.2 h for a saturated vapor atmosphere exposure. A 4 h-LC50 (rat combined sex) of 1461 ppm was determined for DMEA. All alkylalkanolamines studied, except MDEA, were moderately to markedly irritating and caused variable degrees of skin corrosivity; MDEA caused only transient minor skin irritation. In accord with the skin irritancy results, the eye irritancy from 0.005 ml MEA, DMEA, DMIPA and BDEA was severe, and that from MDEA was slight. Exposure to these compounds has implications for occupational health procedures.

  15. Thiolated nanostructured lipid carriers as a potential ocular drug delivery system for cyclosporine A: Improving in vivo ocular distribution.

    PubMed

    Shen, Jie; Deng, Yanping; Jin, Xuefeng; Ping, Qineng; Su, Zhigui; Li, Lejun

    2010-12-15

    Ophthalmic drug delivery with long pre-corneal retention time and high penetration into aqueous humor and intraocular tissues is the key-limiting factor for the treatment of ocular diseases and disorders. Within this study, the conjugate of cysteine-polyethylene glycol monostearate (Cys-PEG-SA) was synthesized and was used to compose the thiolated nanostructured lipid carrier (Cys-NLC) as a potential nanocarrier for the topical ocular administration of cyclosporine A (CyA). The rapid cross-linking process of Cys-PEG-SA in vitro was found in simulated physiological environment. The in vitro CyA release from Cys-NLC was slower than that of non-thiolated nanostructured lipid carriers (NLC) due to the cross-linking of thiomers on the surface of nanocarriers. After topical ocular administration in rabbits, the in vivo ocular distribution of CyA was investigated in comparison of Cys-NLC with non-thiolated NLCs and oil solution. The results showed that CyA concentration in systemic blood was very low and close to the detection limit. The area-under-the-curve (AUC(0-24h)) and mean retention time (MRT(0-24h)) of Cys-NLC group in aqueous humor, tear and eye tissues were significantly higher than that of oil solution, non-thiolated NLCs (p<0.05). These results demonstrated that the thiolated NLC could deliver high level of CyA into intraocular tissues due to its bioadhesive property and sustained release characteristics. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. LC-MS analysis to determine the biodistribution of a polymer coated ilomastat ocular implant.

    PubMed

    Mohamed-Ahmed, Abeer H A; Lockwood, Alastair; Fadda, Hala; Madaan, Shivam; Khaw, Peng T; Brocchini, Steve; Karu, Kersti

    2018-05-16

    Ilomastat is a matrix metalloproteinase inhibitor (MMPi) that has shown the potential to inhibit scarring (fibrosis) by mediating healing after injury or surgery. A long lasting ocular implantable pharmaceutical formulation of ilomastat is being developed to mediate the healing process to prevent scarring after glaucoma filtration surgery. The ilomastat implant was coated with water permeable and biocompatible phosphoryl choline polymer (PC1059) displayed extended slow release of ilomastat in vitro and in vivo. The ocular distribution of ilomastat from the implant in rabbits at day 30 post surgery was determined by the extraction of ilomastat and its internal standard marimastat from the ocular tissues, plasma, aqueous humour and vitreous fluid followed by capillary-flow liquid chromatography (cap-LC), the column effluent was directed into a triple quadrupole mass spectrometer operating in product scan mode. The lower limits of quantification (LLOQs) were 0.3 pg/μL for ocular fluids and plasma, and 3 pg/mg for ocular tissues. The extraction recoveries were 90-95% for ilomastat and its internal standard from ocular tissues. Ilomastat was found in ocular fluids and tissues at day 30 after surgery. The level of ilomastat was 18 times higher in the aqueous humour than vitreous humour. The concentration ranking of ilomastat in the ocular tissues was sclera > bleb conjunctiva > conjunctiva (rest of the eye) > cornea. Mass spectrometry analysis to confirm the presence of ilomastat in the ocular tissues and fluids at day 30 post-surgery establishes the extended release of ilomastat can be achieved in vivo, which is crucial information for optimisation of the ilomastat coated implant. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  17. Safety and Efficacy of Lacrimal Drainage System Plugs for Dry Eye Syndrome: A Report by the American Academy of Ophthalmology.

    PubMed

    Marcet, Marcus M; Shtein, Roni M; Bradley, Elizabeth A; Deng, Sophie X; Meyer, Dale R; Bilyk, Jurij R; Yen, Michael T; Lee, W Barry; Mawn, Louise A

    2015-08-01

    To review the published literature assessing the efficacy and safety of lacrimal drainage system plug insertion for dry eye in adults. Literature searches of the PubMed and Cochrane Library databases were last conducted on March 9, 2015, without date restrictions and were limited to English language abstracts. The searches retrieved 309 unique citations. The primary authors reviewed the titles and abstracts. Inclusion criteria specified reports that provided original data on plugs for the treatment of dry eyes in at least 25 patients. Fifty-three studies of potential relevance were assigned to full-text review. The 27 studies that met the inclusion criteria underwent data abstraction by the panels. Abstracted data included study characteristics, patient characteristics, plug type, insertion technique, treatment response, and safety information. All studies were observational and rated by a methodologist as level II or III evidence. The plugs included punctal, intracanalicular, and dissolving types. Fifteen studies reported metrics of improvement in dry eye symptoms, ocular-surface status, artificial tear use, contact lens comfort, and tear break-up time. Twenty-five studies included safety data. Plug placement resulted in ≥50% improvement of symptoms, improvement in ocular-surface health, reduction in artificial tear use, and improved contact lens comfort in patients with dry eye. Serious complications from plugs were infrequent. Plug loss was the most commonly reported problem with punctal plugs, occurring on average in 40% of patients. Overall, among all plug types, approximately 9% of patients experienced epiphora and 10% required removal because of irritation from the plugs. Canaliculitis was the most commonly reported problem for intracanalicular plugs and occurred in approximately 8% of patients. Other complications were reported in less than 4% of patients on average and included tearing, discomfort, pyogenic granuloma, and dacryocystitis. On the basis of level II and III evidence in these studies, plugs improve the signs and symptoms of moderate dry eye that are not improved with topical lubrication, and they are well tolerated. There are no level I studies that describe the efficacy or safety of lacrimal drainage system plugs. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  18. Minimally invasive microneedles for ocular drug delivery.

    PubMed

    Thakur Singh, Raghu Raj; Tekko, Ismaiel; McAvoy, Kathryn; McMillan, Hannah; Jones, David; Donnelly, Ryan F

    2017-04-01

    Anterior and posterior segment eye diseases are highly challenging to treat, due to the barrier properties and relative inaccessibility of the ocular tissues. Topical eye drops and systemically delivered treatments result in low bioavailability. Alternatively, direct injection of medication into the ocular tissues is clinically employed to overcome the barrier properties, but injections cause significant tissue damage and are associated with a number of untoward side effects and poor patient compliance. Microneedles (MNs) has been recently introduced as a minimally invasive means for localizing drug formulation within the target ocular tissues with greater precision and accuracy than the hypodermic needles. Areas covered: This review article seeks to provide an overview of a range of challenges that are often faced to achieve efficient ocular drug levels within targeted tissue(s) of the eye. It also describes the problems encountered using conventional hypodermic needle-based ocular injections for anterior and posterior segment drug delivery. It discusses research carried out in the field of MNs, to date. Expert opinion: MNs can aid in localization of drug delivery systems within the selected ocular tissue. And, hold the potential to revolutionize the way drug formulations are administered to the eye. However, the current limitations and challenges of MNs application warrant further research in this field to enable its widespread clinical application.

  19. Ocular-specific ER stress reduction rescues glaucoma in murine glucocorticoid-induced glaucoma

    PubMed Central

    Zode, Gulab S.; Sharma, Arti B.; Lin, Xiaolei; Searby, Charles C.; Bugge, Kevin; Kim, Gun Hee; Clark, Abbot F.; Sheffield, Val C.

    2014-01-01

    Administration of glucocorticoids induces ocular hypertension in some patients. If untreated, these patients can develop a secondary glaucoma that resembles primary open-angle glaucoma (POAG). The underlying pathology of glucocorticoid-induced glaucoma is not fully understood, due in part to lack of an appropriate animal model. Here, we developed a murine model of glucocorticoid-induced glaucoma that exhibits glaucoma features that are observed in patients. Treatment of WT mice with topical ocular 0.1% dexamethasone led to elevation of intraocular pressure (IOP), functional and structural loss of retinal ganglion cells, and axonal degeneration, resembling glucocorticoid-induced glaucoma in human patients. Furthermore, dexamethasone-induced ocular hypertension was associated with chronic ER stress of the trabecular meshwork (TM). Similar to patients, withdrawal of dexamethasone treatment reduced elevated IOP and ER stress in this animal model. Dexamethasone induced the transcriptional factor CHOP, a marker for chronic ER stress, in the anterior segment tissues, and Chop deletion reduced ER stress in these tissues and prevented dexamethasone-induced ocular hypertension. Furthermore, reduction of ER stress in the TM with sodium 4-phenylbutyrate prevented dexamethasone-induced ocular hypertension in WT mice. Our data indicate that ER stress contributes to glucocorticoid-induced ocular hypertension and suggest that reducing ER stress has potential as a therapeutic strategy for treating glucocorticoid-induced glaucoma. PMID:24691439

  20. Novel Approaches in Formulation and Drug Delivery using Contact Lenses

    PubMed Central

    Singh, Kishan; Nair, Anroop B; Kumar, Ashok; Kumria, Rachna

    2011-01-01

    The success of ocular delivery relies on the potential to enhance the drug bioavailability by controlled and extended release of drug on the eye surface. Several new approaches have been attempted to augment the competence and diminish the intrinsic side effects of existing ocular drug delivery systems. In this contest, progress has been made to develop drug-eluting contact lens using different techniques, which have the potential to control and sustain the delivery of drug. Further, the availability of novel polymers have facilitated and promoted the utility of contact lenses in ocular drug delivery. Several research groups have already explored the feasibility and potential of contact lens using conventional drugs for the treatment of periocular and intraocular diseases. Contact lenses formulated using modern technology exhibits high loading, controlled drug release, apposite thickness, water content, superior mechanical and optical properties as compared to commercial lenses. In general, this review discus various factors and approaches designed and explored for the successful delivery of ophthalmic drugs using contact lenses as drug delivery device PMID:24826007

  1. Downbeat nystagmus due to ranitidine in a pediatric patient.

    PubMed

    Butragueño Laiseca, Laura; Toledo Del Castillo, Blanca; Rodríguez Jimenez, Cristina; Manrique-Rodríguez, Silvia; Pérez Moreno, Jimena

    2017-07-01

    Ranitidine has not been considered as a potential cause of ocular movement conditions. However, it is known that the vestibular nucleus complex, that has a key role in gaze control and vestibule-ocular reflexes, receives hypothalamic histaminergic innervations. Some studies reported the effect of ranitidine blocking the excitatory responses of vestibular nuclei neurons to histamine. We report the first case of a downbeat nystagmus secondary to ranitidine in an infant. A 3-month-old female developed a downbeat gaze after starting treatment with ranitidine for a pediatric gastroesophageal reflux disease. Microbiological test were negative and neuroblastoma evaluation was normal. As ranitidine is widely prescribed in the pediatric population, clinicians should be aware of its potential to cause ocular movements disorders. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  2. Mechanics of mouse ocular motor plant quantified by optogenetic techniques.

    PubMed

    Stahl, John S; Thumser, Zachary C; May, Paul J; Andrade, Francisco H; Anderson, Sean R; Dean, Paul

    2015-09-01

    Rigorous descriptions of ocular motor mechanics are often needed for models of ocular motor circuits. The mouse has become an important tool for ocular motor studies, yet most mechanical data come from larger species. Recordings of mouse abducens neurons indicate the mouse mechanics share basic viscoelastic properties with larger species but have considerably longer time constants. Time constants can also be extracted from the rate at which the eye re-centers when released from an eccentric position. The displacement can be accomplished by electrically stimulating ocular motor nuclei, but electrical stimulation may also activate nearby ocular motor circuitry. We achieved specific activation of abducens motoneurons through photostimulation in transgenic mice expressing channelrhodopsin in cholinergic neurons. Histology confirmed strong channelrhodopsin expression in the abducens nucleus with relatively little expression in nearby ocular motor structures. Stimulation was delivered as 20- to 1,000-ms pulses and 40-Hz trains. Relaxations were modeled best by a two-element viscoelastic system. Time constants were sensitive to stimulus duration. Analysis of isometric relaxation of isolated mouse extraocular muscles suggest the dependence is attributable to noninstantaneous decay of active forces in non-twitch fibers following stimulus offset. Time constants were several times longer than those obtained in primates, confirming that the mouse ocular motor mechanics are relatively sluggish. Finally, we explored the effects of 0.1- to 20-Hz sinusoidal photostimuli and demonstrated their potential usefulness in characterizing ocular motor mechanics, although this application will require further data on the temporal relationship between photostimulation and neuronal firing in extraocular motoneurons.

  3. Surgery-Related Contact Dermatitis: A Review of Potential Irritants and Allergens.

    PubMed

    Cook, Kevin A; Kelso, John M

    Surgical procedures utilize an increasing number of medical products including antiseptics, anesthetics, gloves, suture materials, tissue adhesives, topical antibiotics, and bandages. Many of these products have irritant potential. Allergic contact dermatitis has also been reported. This review covers preoperative, operative, and postoperative exposures that may result in contact dermatitis. Testing with standard patch panels such as T.R.U.E. Test and the North American Contact Dermatitis Group 65 allergen series does not evaluate for all relevant contactants. A thorough understanding of potential exposures is vital to effectively evaluate a patient with surgery-related contact dermatitis. A systematic approach is needed to ensure that standard patch panels and supplementary patches adequately address each encountered contactant. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. Poly(N-isopropylacrylamide)-chitosan as thermosensitive in situ gel-forming system for ocular drug delivery.

    PubMed

    Cao, Yanxia; Zhang, Can; Shen, Wenbin; Cheng, Zhihong; Yu, Liangli Lucy; Ping, Qineng

    2007-07-31

    A novel copolymer, poly(N-isopropylacrylamide)-chitosan (PNIPAAm-CS), was investigated for its thermosensitive in situ gel-forming properties and potential utilization for ocular drug delivery. The thermal sensitivity and low critical solution temperature (LCST) were determined by the cloud point method. PNIPAAm-CS had a LCST of 32 degrees C, which is close to the surface temperature of the eye. The in vivo ocular pharmacokinetics of timolol maleate in PNIPAAm-CS solution were evaluated and compared to that in conventional eye drop solution by using rabbits according to the microdialysis method. The C(max) of timolol maleate in aqueous fluid for the PNIPAAm-CS solution was 11.2 microg/ml, which is two-fold higher than that of the conventional eye drop, along with greater AUC. Furthermore, the PNIPAAm-CS gel-forming solution of timolol maleate had a stronger capacity to reduce the intra-ocular pressure (IOP) than that of the conventional eye drop of same concentration over a period of 12 h. In addition, the MTT assay showed that there is little cytotoxicity of PNIPAAm-CS at concentration range of 0.5-400 microg/ml. These results suggest that PNIPAAm-CS is a potential thermosensitive in situ gel-forming material for ocular drug delivery, and it may improve the bio-availability, efficacy, and compliance of some eye drugs.

  5. Relational dimension of irritability following traumatic brain injury: a qualitative analysis.

    PubMed

    Hammond, Flora M; Davis, Christine S; Cook, James R; Philbrick, Peggy; Hirsch, Mark A

    2012-01-01

    Irritability is a common long-term sequelae of traumatic brain injury (TBI). In a prior study on TBI irritability, relational interactions were one of four dimensions of irritability occurrence and precipitation. This present analysis examines these same data in greater detail. Fifty focus group transcripts from a study on irritability were re-analysed to examine: (1) irritability in spousal relationships following TBI, (2) retrospective accounts of spousal interactions contributing to irritability and (3) impact of irritability on marital relationships. Grounded Theory was used to develop themes, metacodes and theories. Several theories emerged regarding irritability with respect to spousal relations, all based on the overarching theory that irritability in people with TBI has a strong relational component involved in triggering, experiencing and preventing irritability. Sub-theories supporting this include: (1) irritability breeds further irritability, (2) spousal responses can trigger irritability among persons with TBI and vice versa, (3) difficulties making emotional connections may incite negative interactions, (4) expectations of others may contribute to irritable behaviour, and (5) communication breakdowns may provoke irritability. Irritability associated with TBI resides in the family system as well as the individual. In treating irritability one should include comprehensive assessment and assistance to improve interpersonal interactions.

  6. "Johnny Poppers": a cause of serious ocular injury

    PubMed Central

    MacAndie, K.; Kyle, P.

    1998-01-01

    AIMS/BACKGROUND—The causes of blunt ocular trauma are many and diverse. We present two cases of ocular injury caused by an unusual form of weapon called a "Johnny Popper". There follows a theoretical and experimental evaluation of the velocity of the projectiles fired by this device.
METHODS—A Johnny Popper was constructed under expert guidance. The elastic properties of the device were measured and this allowed calculation of a theoretical exit velocity of the projectiles fired. The weapon was subsequently fired under test conditions which permitted the exit velocity of the projectiles fired to be measured directly.
RESULTS—The theoretical velocity of the projectiles was calculated as 80 ms-1 and the experimentally measured velocity was 57 ms-1.
CONCLUSIONS—Johnny Poppers are a previously undescribed and unique form of home made weapon. They are intended for playful mischief, but have the potential to cause serious ocular trauma.

 Keywords: ocular trauma; projectiles PMID:9924377

  7. Recalcitrant Epithelial Ingrowth After SMILE Treated With a Hydrogel Ocular Sealant.

    PubMed

    Thulasi, Praneetha; Kim, Sang Woo; Shetty, Rohit; Randleman, J Bradley

    2015-12-01

    To report a case of recalcitrant epithelial ingrowth after small incision lenticule extraction (SMILE) treated successfully with a novel hydrogel ocular sealant. Case report and literature review. A 32-year-old man who underwent small incision lenticule extraction (SMILE) complicated by difficult lenticule extraction developed visually significant epithelial ingrowth. He then underwent two flap lifts and epithelial scrapings and flap edge suturing with recurrence of epithelial ingrowth despite these interventions. He subsequently underwent repeat scraping, followed by hydrogel ocular sealant placement (ReSure Sealant; Ocular Therapeutix, Inc., Bedford, MA), which prevented recurrence of epithelial ingrowth and reduced corneal haze. The patient was also found to have undiagnosed diabetes, suggesting that just as in LASIK, diabetes may be a risk factor for epithelial ingrowth after SMILE. Interface epithelial ingrowth is a potential complication after SMILE and diabetes may be a risk factor for this complication. Hydrogel ocular sealant may be effective after SMILE to prevent epithelial ingrowth into the interface. Copyright 2015, SLACK Incorporated.

  8. Ear swelling test by using laser speckle imaging with a long exposure time

    NASA Astrophysics Data System (ADS)

    Kalchenko, Vyacheslav; Kuznetsov, Yuri; Preise, Dina; Meglinski, Igor; Harmelin, Alon

    2014-06-01

    Laser speckle imaging with long exposure time has been applied noninvasively to visualize the immediate reaction of cutaneous vessels in mice in response to a known primary irritant and potential allergen-methyl salicylate. The compound has been used topically on the surface of the pinna and the reaction of the vascular network was examined. We demonstrate that irritant-induced acute vascular reaction can be effectively and accurately detected by laser speckle imaging technique. The current approach holds a great promise for application in routine screening of the cutaneous vascular response induced by contact agents, screenings of mouse ear swelling test, and testing the allergenic potential of new synthetic materials and healthcare pharmaceutical products.

  9. Stimuli-Responsive Polymeric Systems for Controlled Protein and Peptide Delivery: Future Implications for Ocular Delivery.

    PubMed

    Mahlumba, Pakama; Choonara, Yahya E; Kumar, Pradeep; du Toit, Lisa C; Pillay, Viness

    2016-07-30

    Therapeutic proteins and peptides have become notable in the drug delivery arena for their compatibility with the human body as well as their high potency. However, their biocompatibility and high potency does not negate the existence of challenges resulting from physicochemical properties of proteins and peptides, including large size, short half-life, capability to provoke immune responses and susceptibility to degradation. Various delivery routes and delivery systems have been utilized to improve bioavailability, patient acceptability and reduce biodegradation. The ocular route remains of great interest, particularly for responsive delivery of macromolecules due to the anatomy and physiology of the eye that makes it a sensitive and complex environment. Research in this field is slowly gaining attention as this could be the breakthrough in ocular drug delivery of macromolecules. This work reviews stimuli-responsive polymeric delivery systems, their use in the delivery of therapeutic proteins and peptides as well as examples of proteins and peptides used in the treatment of ocular disorders. Stimuli reviewed include pH, temperature, enzymes, light, ultrasound and magnetic field. In addition, it discusses the current progress in responsive ocular drug delivery. Furthermore, it explores future prospects in the use of stimuli-responsive polymers for ocular delivery of proteins and peptides. Stimuli-responsive polymers offer great potential in improving the delivery of ocular therapeutics, therefore there is a need to consider them in order to guarantee a local, sustained and ideal delivery of ocular proteins and peptides, evading tissue invasion and systemic side-effects.

  10. Silibinin, dexamethasone, and doxycycline as potential therapeutic agents for treating vesicant-inflicted ocular injuries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tewari-Singh, Neera, E-mail: Neera.Tewari-Singh@ucdenver.edu; Jain, Anil K., E-mail: Anil.Jain@ucdenver.edu; Inturi, Swetha, E-mail: Swetha.Inturi@ucdenver.edu

    There are no effective and approved therapies against devastating ocular injuries caused by vesicating chemical agents sulfur mustard (SM) and nitrogen mustard (NM). Herein, studies were carried out in rabbit corneal cultures to establish relevant ocular injury biomarkers with NM for screening potential efficacious agents in laboratory settings. NM (100 nmol) exposure of the corneas for 2 h (cultured for 24 h), showed increases in epithelial thickness, ulceration, apoptotic cell death, epithelial detachment microbullae formation, and the levels of VEGF, cyclooxygenase-2 (COX-2) and matrix metalloproteinase-9 (MMP-9). Employing these biomarkers, efficacy studies were performed with agent treatments 2 h and everymore » 4 h thereafter, for 24 h following NM exposure. Three agents were evaluated, including prescription drugs dexamethasone (0.1%; anti-inflammatory steroid) and doxycycline (100 nmol; antibiotic and MMP inhibitor) that have been studied earlier for treating vesicant-induced eye injuries. We also examined silibinin (100 μg), a non-toxic natural flavanone found to be effective in treating SM analog-induced skin injuries in our earlier studies. Treatments of doxycycline + dexamethasone, and silibinin were more effective than doxycycline or dexamethasone alone in reversing NM-induced epithelial thickening, microbullae formation, apoptotic cell death, and MMP-9 elevation. However, dexamethasone and silibinin alone were more effective in reversing NM-induced VEGF levels. Doxycycline, dexamethasone and silibinin were all effective in reversing NM-induced COX-2 levels. Apart from therapeutic efficacy of doxycycline and dexamethasone, these results show strong multifunctional efficacy of silibinin in reversing NM-induced ocular injuries, which could help develop effective and safe therapeutics against ocular injuries by vesicants. -- Highlights: ► Established injury biomarkers in rabbit corneal culture with nitrogen mustard (NM) ► This NM model is a cost effective system to evaluate and optimize therapeutics. ► Show that doxycycline and dexamethasone reduce NM-caused ocular injuries ► Demonstrate that silibinin effectively reverses NM-caused ocular injury endpoints ► Suggest optimization of identified agents against ocular injuries by vesicants.« less

  11. PEDIATRIC OCULAR TOXOCARIASIS IN JIANGSU PROVINCE, EASTERN CHINA.

    PubMed

    Zhang, Hai-Fang; Hua, Hai-Yong; Wang, Wei

    2015-01-01

    Ocular toxocariasis is caused by migration of a Toxocara larva through the posterior eye. We report the first case of pediatric ocular toxocariasis caused by T. canis in Jiangsu Province, eastern China. A 6-year-old girl presented to Suzhou Municipal Children's Hospital with a complaint of right eye redness, minimal white discharge, no photophobia, eye pain, visual impairment, fever or arthralgia. She was initially diagnosed as having conjunctivitis; however, a 2-month treatment with lomefloxacin 0.3% eye drops gave no improvements. The diagnosis was made based on medical history (contact with dogs), clinical features and detection of T. canis IgG antibodies with an enzyme-linked immunosorbent assay (ELISA). Anthelmintic therapy with albendazole in combination with prednisolone resulted in improvement of the ocular symptoms. Ocular toxocariasis is rarely reported in China. However, the rapid economic development in China, could mean an increase in pet dogs with the potential increased risk of contracting toxocariasis if no control measures are taken. Disposal of pet litter, deworming of infected pets, complete cooking of meats, thorough rinsing of fruits and vegetables, and good hand-washing may help prevent human infections. Ocular toxocariasis should be considered in the differential diagnosis of patients with conjunctivitis that does not resolve with treatment.

  12. Detection of myasthenia gravis using electrooculography signals.

    PubMed

    Liang, T; Boulos, M I; Murray, B J; Krishnan, S; Katzberg, H; Umapathy, K

    2016-08-01

    Myasthenia gravis (MG) is an autoimmune neuromuscular disorder resulting from skeletal muscle weakness and fatigue. An early common symptom is fatigable weakness of the extrinsic ocular muscles; if symptoms remain confined to the ocular muscles after a few years, this is classified as ocular myasthenia gravis (OMG). Diagnosis of MG when there are mild, isolated ocular symptoms can be difficult, and currently available diagnostic techniques are insensitive, non-specific or technically cumbersome. In addition, there are no accurate biomarkers to follow severity of ocular dysfunction in MG over time. Single-fiber electromyography (SFEMG) and repetitive nerve stimulation (RNS) offers a way of detecting and measuring ocular muscle dysfunction in MG, however, challenges of these methods include a poor signal to noise ratio in quantifying eye muscle weakness especially in mild cases. This paper presents one of the attempts to use the electric potentials from the eyes or electrooculography (EOG) signals but obtained from three different forms of sleep testing to differentiate MG patients from age- and gender-matched controls. We analyzed 8 MG patients and 8 control patients and demonstrated a difference in the average eye movements detected between the groups. A classification accuracy as high as 68.8% was achieved using a linear discriminant analysis based classifier.

  13. A comprehensive review on contact lens for ophthalmic drug delivery.

    PubMed

    Xu, Jiawen; Xue, Yingyan; Hu, Gaoyong; Lin, Tianyu; Gou, Jingxin; Yin, Tian; He, Haibing; Zhang, Yu; Tang, Xing

    2018-07-10

    With the prevalence of electronic devices and an aging population, the number of people affected with eye disease is increasing year by year. In spite of a large number of eye drops on the market, most of them do not perform sufficiently, due to rapid clearance mechanisms and ocular barriers. To enhance drug delivery to the eye, a number of novel formulations for ocular diseases have been investigated over recent decades, aiming to increase drug retention and permeation while also allowing for sustained drug release over prolonged periods. The contact lens, initially used to correct visual acuity and beautify female eyes, is one such novel formulation with outstanding potential. Recently, contact lenses have been extensively used for ocular drug delivery to enhance ocular bioavailability and reduce side effects, and are particularly suitable for the treatment of chronic diseases, and thus are of interest to ophthalmic scientists. This review summarizes contact lens classification, methods of preparation, strategies for integrating drugs into lenses, in vitro and in vivo studies, and clinical applications. This review also discusses the current state of ocular drug therapy and provides an outlook for future therapeutic opportunities in the field of ocular drug delivery. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A comparative study of the usefulness of color vision, photostress recovery time, and visual evoked potential tests in early detection of ocular toxicity from hydroxychloroquine.

    PubMed

    Heravian, Javad; Saghafi, Massoud; Shoeibi, Naser; Hassanzadeh, Samira; Shakeri, Mohammad Taghi; Sharepoor, Maria

    2011-08-01

    Ocular toxicity from hydroxychloroquine (HCQ) is rare, but its potential permanence and severity makes it imperative to employ measures and screening protocols to minimize its occurrence. This study was performed to assess the usefulness of color vision, photo stress recovery time (PSRT), and visual evoked potentials (VEP) in early detection of ocular toxicity of HCQ, in patients with rheumatoid arthritis (RA) and systemic lupus erythematosus (SLE). 86 patients were included in the study and divided into three groups: (1) with history of HCQ use: interventional 1 (Int.1) without fundoscopic changes and Int.2 with fundoscopic changes; and (2) without history of HCQ use, as control. Visual field, color vision, PSRT and VEP results were recorded for all patients and the effect of age, disease duration, treatment duration and cumulative dose of HCQ on each test was assessed in each group. There was a significant relationship among PSRT and age, treatment duration, cumulative dose of HCQ and disease duration (P<0.001 for all). Color vision was normal in all the cases. P100 amplitude was not different between the three groups (P=0.846), but P100 latency was significantly different (P=0.025) and for Int.2 it was greater than the others. The percentage of abnormal visual fields for Int.2 was more than Int.1 and control groups (P=0.002 and P=0.005 respectively), but Int.1 and control groups were not significantly different (P>0.50). In the early stages of maculopathy, P100 latencies of VEP and PSRT are useful predictors of HCQ ocular toxicity. In patients without ocular symptoms and fundoscopic changes, the P100 latency of VEP predicts more precisely than the others.

  15. Health impacts of chemical irritants used for crowd control: a systematic review of the injuries and deaths caused by tear gas and pepper spray.

    PubMed

    Haar, Rohini J; Iacopino, Vincent; Ranadive, Nikhil; Weiser, Sheri D; Dandu, Madhavi

    2017-10-19

    Chemical irritants used in crowd control, such as tear gases and pepper sprays, are generally considered to be safe and to cause only transient pain and lacrimation. However, there are numerous reports that use and misuse of these chemicals may cause serious injuries. We aimed to review documented injuries from chemical irritants to better understand the morbidity and mortality associated with these weapons. We conducted a systematic review using PRISMA guidelines to identify injuries, permanent disabilities, and deaths from chemical irritants worldwide between January 1, 1990 and March 15, 2015. We reviewed injuries to different body systems, injury severity, and potential risk factors for injury severity. We also assessed region, context and quality of each included article. We identified 31 studies from 11 countries. These reported on 5131 people who suffered injuries, two of whom died and 58 of whom suffered permanent disabilities. Out of 9261 total injuries, 8.7% were severe and required professional medical management, while 17% were moderate and 74.3% were minor. Severe injuries occurred to all body systems, with the majority of injuries impacting the skin and eyes. Projectile munition trauma caused 231 projectile injuries, with 63 (27%) severe injuries, including major head injury and vision loss. Potentiating factors for more severe injury included environmental conditions, prolonged exposure time, and higher quantities of chemical agent in enclosed spaces. Although chemical weapons may have a limited role in crowd control, our findings demonstrate that they have significant potential for misuse, leading to unnecessary morbidity and mortality. A nuanced understanding of the health impacts of chemical weapons and mitigating factors is imperative to avoiding indiscriminate use of chemical weapons and associated health consequences.

  16. Rates of allergic sensitization and irritation to oxybenzone-containing sunscreen products: a quantitative meta-analysis of 64 exaggerated use studies.

    PubMed

    Agin, Patricia P; Ruble, Karen; Hermansky, Steven J; McCarthy, Timothy J

    2008-08-01

    Oxybenzone is an active ingredient found in sunscreen products that absorbs a broad spectrum of ultraviolet (UV) light, with absorbance peaking in the UVB region and extending into the UVA region. Although the overall incidence of sensitization and irritation associated with oxybenzone in the general population remains unclear, a few studies have reported on the incidence in specific circumstances. However, the relevance of these studies to the general population is limited, because the sample populations reported in these papers generally have consisted of individuals who sought medical attention for pre-existing skin conditions. Therefore, the reported incidence of allergic reactions to oxybenzone in these studies may be overestimated as related to the general population. The objective of this meta-analysis was to determine the safety of oxybenzone in participants recruited from the general population. The data from 64 unpublished exaggerated use human repeat insult patch tests (HRIPT) and photoallergy (PA) studies sponsored by Schering-Plough HealthCare Products Inc. between 1992 and 2006 were aggregated and analyzed to evaluate the irritancy and sensitization potential of sunscreen products containing oxybenzone at concentrations between 1% and 6%. Forty-eight of 19 570 possible dermal responses were considered to be suggestive of irritation or sensitization; the mean rate of responses across all formulations was 0.26%. Sensitization rates did not correlate significantly with oxybenzone concentration. The available re-challenge data indicated that only eight of these responses were contact allergies from oxybenzone, and the mean rate of contact allergy to oxybenzone was 0.07%. The source of the skin responses was not confirmed for 15 subjects who were lost to follow-up. However, all subjects were given the opportunity to participate in follow-up testing. Our data indicate that sunscreen products formulated with 1-6% oxybenzone do not possess a significant sensitization or irritation potential for the general public. Furthermore, these data suggest that the incidence rate implied in the published literature overestimates the actual incidence of sensitization/irritation due to oxybenzone-containing sunscreen products in the general population.

  17. Final report of the cosmetic ingredient review expert panel on the safety assessment of Polyisobutene and Hydrogenated Polyisobutene as used in cosmetics.

    PubMed

    2008-01-01

    Polyisobutene and Hydrogenated Polyisobutene are homopolymers of isobutene. These ingredients are produced in a wide range of molecular weights. Polybutene is a chemically related cosmetic ingredient previously determined to be safe as used in cosmetic products. Polyisobutene is used in cosmetic products as a binder, film former, and nonaqueous viscosity-increasing agent. Hydrogenated Polyisobutene functions as a skin-conditioning agent-emollient and nonaqueous viscosity-increasing agent with a wide range of uses in cosmetic formulations. The estimated octanol water partition coefficient for Hydrogenated Polyisobutene and Polybutene is log K(ow) of 13.27 and the estimated water solubility was 5.6 x 10(-3) ng/L for Hydrogenated Polyisobutene and Polybutene. Acute oral toxicity testing demonstrated no effects other than lethargy in one rat study. The oral LD(50) was > 5.0 g/kg in rats. No short-term or subchronic animal toxicity data were available. A 2-year chronic oral toxicity study of Polybutene revealed no gross or microscopic pathological changes, and no changes in body weights or food consumption, hematological results, urology, or tumor formation that could be correlated with Polybutene ingestion, except that in the 20,000 ppm group, three out of six males that died between weeks 17 and 24 exhibited hematuria. In a 2-year chronic oral toxicity study of Polybutene in Beagle dogs, no abnormalities in body weight, food consumption, survival, behavioral patterns, hematology, blood chemistry, urinalysis, liver function, gross and histopathologic examinations, or organ weights and ratios were reported. In a three-generation reproductive study in Charles River albino rats that ingested Polybutene, none of the animals in successive generations differed from controls with regard to weight gain, litter size, the number of stillborn, and the number of viable pups during lactation. The survival, body weights, and reactions of test animals were comparable to those of controls. Neither Polyisobutene nor Hydrogenated Polyisobutene were ocular irritants, nor were they dermal irritants or sensitizers. Polyisobutene was not comedogenic in a rabbit ear study. Polyisobutene did not induce transformation in the Syrian hamster embryo (SHE) cell transformation assay, but did enhance 3-methylcholanthrene-induced transformation of C3H/10T1/2 cells. In a carcinogenicity study in mice, Polyisobutene was not carcinogenic, nor did it promote the carcinogenicity of 7,12-dimethylbenz(alpha)anthracene. Clinical patch tests uncovered no evidence of dermal irritation and repeat-insult patch tests with a product containing 4% Hydrogenated Polyisobutene or 1.44% Hydrogenated Polyisobutene found no reactions greater than slight erythema. These products also were not phototoxic or photoallergenic. The product containing 4% Hydrogenated Polyisobutene was not an ocular irritant in a clinical test. The Cosmetic Ingredient Review (CIR) Expert Panel recognized that there are data gaps regarding use and concentration of these ingredients. However, the overall information available on the types of products in which these ingredients are used and at what concentrations indicate a pattern of use, which was considered by the Expert Panel in assessing safety. Although there is an absence of dermal absorption data for Polyisobutene and Hydrogenated Polyisobutene, the available octanol water partition coefficient data and the low solubility in water suggest very slow absorption, so additional data are not needed. Gastrointestinal absorption is also not a major concern due to the low solubility of these chemicals. Although one in vitro study did report that Polyisobutene did promote cellular transformation, a mouse study did not find evidence of tumor promotion. Because lifetime exposure studies using rats and dogs exposed to Polybutene failed to demonstrate any carcinogenic or tumor promotion effect, and a three-generation reproductive/developmental toxicity study produced no adverse effects, the CIR Expert Panel does not believe these large, mostly insoluble polymers present any risks in the practices of use and concentration as described in this safety assessment.

  18. Design and evaluation of flexible membrane vesicles (FMVs) for enhanced topical delivery of capsaicin.

    PubMed

    Raza, Kaisar; Singh, Bhupinder; Mahajan, Anadi; Negi, Poonam; Bhatia, Amit; Katare, O P

    2011-05-01

    Capsaicin, extracted from the fruits of Capsicum, is a powerful local stimulant with strong rubifacient action, devoid of vesication. Topical use of capsaicin is quite common in the treatment of various pain-associated musculo-skeletal disorders, itching and neuropathy. Despite its high pharmacodynamic potential, the patient compliance to the drug is reported to be poor owing to multiple skin problems like irritation, burning sensation, and erythma. The present study targets the encasement of drug in the interiors of flexible membrane vesicles (FMVs), as these are reported to have better penetration in the deeper layers of skin, thus leading to enhanced localization of drug and consequently, decreased skin irritation. Multilamellar drug-loaded FMVs, prepared by thin-film hydration were evaluated for their efficacy in vitro and in vivo. When compared with conventional liposomes, the formulated FMVs showed higher skin retention during ex vivo permeation studies employing LACA mice skin, higher analgesic potential using radiant tail-flick method in mice, and better flexibility in regaining their size. Being less of an irritant, these vesicular carriers were also found to be more comfortable on human skin. Thus, the capsaicin-loaded FMVs offer high potential as topical drug delivery technologies with improved patient acceptance and effectiveness.

  19. Update in Current Diagnostics and Therapeutics of Dry Eye Disease.

    PubMed

    Thulasi, Praneetha; Djalilian, Ali Reza

    2017-11-01

    Dry eye disease (DED) represents a heterogeneous group of conditions with tear film insufficiency and signs and/or symptoms of ocular surface irritation. The clinical manifestations of DED can be highly variable; hence the diagnosis is often based on a combination of symptoms, signs, and clinical tests, given that any one of these alone would miss a significant number of patients. Similarly, the treatment must often be tailored to each patient by targeting the specific mechanisms involved in his or her disease. The purpose of this review is to summarize recent advances that have allowed us to better recognize, categorize, and treat patients with DED. The most notable new diagnostic tests in DED are tear film osmolarity, inflammatory biomarkers, and meibomian gland imaging. Therapeutically, anti-inflammatory therapy, meibomian gland heating and expression, and scleral contact lenses are some of the latest options available for treating DED. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. [Aerophagia due to noninvasive mechanical ventilation: a first manifestation of silent gastric carcinoma].

    PubMed

    Mayoralas Alises, S; Gómez Mendieta, M A; Díaz Lobato, S

    2003-07-01

    Noninvasive mechanical ventilation (NIV) techniques have proven useful in treating patients with respiratory insufficiency of various etiologies. The problems most frequently associated with this ventilatory technique are the appearance of nasal and oropharyngeal dryness, pressure sores where the nasal mask touches the skin, ocular irritation due to air leakage and epistaxis. Aerophagia appears in up to half the patients with NIV and may lead to discontinuing treatment. Drugs that accelerate gastrointestinal transit, changes in the respirator settings or changing the ventilatory modality may help to ameliorate the problem. When the symptoms arising from abdominal distension due to NIV are intense and persistent, the coexistence of an underlying abdominal pathology must be ruled out. We report the cases of two patients with these characteristics in whom gastroscopy revealed gastric carcinoma. We think that patients with persistent symptoms of aerophagia that cannot be controlled by the usual measures should undergo endoscopic exploration to rule out silent gastric disease.

  1. Safety and efficacy of intravitreal bevacizumab followed by pegaptanib maintenance as a treatment regimen for age-related macular degeneration.

    PubMed

    Hughes, Mark S; Sang, Delia N

    2006-01-01

    Vascular endothelial growth factor (VEGF)-A, both necessary and sufficient in promoting ocular neovascularization, is an attractive therapeutic target. Combining nonselective and selective VEGF blockade may provide clinical benefit with minimal risks in the treatment of neovascular age-related macular degeneration (AMD). Twenty patients with all subtypes of neovascular AMD and a broad range of baseline vision were treated with intravitreal bevacizumab followed by pegaptanib sodium for 54 weeks. Visual acuity measurements, biomicroscopy, funduscopy, fluorescein angiography, optical coherence tomography, and adverse event assessments were performed. Mean visual acuity improved from approximately 20/200 at baseline to 20/80. All patients experienced an improvement in retinal thickness, ranging from -47 to -297 microns. Adverse events were limited to transient irritation or redness. No significant elevation in intraocular pressure occurred following either bevacizumab or pegaptanib injections. Nonselective VEGF blockade with bevacizumab induction and selective VEGF165 blockade with pegaptanib as maintenance therapies may offer clinically meaningful outcomes with acceptable safety profiles in patients with AMD.

  2. Safety assessment of modified terephthalate polymers as used in cosmetics.

    PubMed

    Becker, Lillian C; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2014-01-01

    The safety of 6 modified terephthalate polymers as cosmetic ingredients was assessed. These ingredients mostly function as exfoliants, bulking agents, hair fixatives, and viscosity-increasing agents-nonaqueous. Polyethylene terephthalate (PET) is used in leave-on products up to 100% and in rinse-off products up to 2%. The Cosmetic Ingredient Review Expert Panel (Panel) considered that the PET used in cosmetics is chemically equivalent to that used in medical devices. The Panel determined that the Food and Drug Administration's determination of safety of PET in several medical devices, which included human and animal safety data, can be used as the basis for the determination of safety of PET and related polymers used in cosmetics. Use studies of cosmetic eye products that contain PET demonstrated no ocular irritation or dermal sensitization. The Panel concluded that modified terephthalate polymers were safe as cosmetic ingredients in the practices of use and concentration described in this safety assessment. © The Author(s) 2014.

  3. 2,4-Dinitroanisole (DNAN) (2014).

    PubMed

    2018-01-01

    2,4-dinitroanisole (DNAN) is a warhead explosive currently under investigation as a replacement for TNT in melt-cast insensitive munitions. In animal studies, DNAN is a mild ocular and skin irritant with a significant potential for dermal absorption.  It is not a dermal sensitizer.  Acute and subacute rat inhalation studies demonstrated minimal toxicity with LC 50 and LOAEL endpoints of 2.9 and 150 mg/m 3 , respectively.  In rat oral toxicity studies (14 and 90 days) organ weight and clinical chemistry changes suggested hepatocellular injury and anemia, particularly in females.  In males there was evidence of testicular injury at the high-dose level (80 mg/kg/day).  The NOAELs for the 14- and 90-day studies were 25 and 5 mg/kg/day, respectively, with a calculated BMDL 10 value of 0.93 mg/kg/day.  No chronic, carcinogenicity or reproductive/developmental toxicity data were available for DNAN, but a maternal and fetal NOAEL of 5.1 mg/kg/day was inferred.  DNAN is considered non-mutagenic and non-genotoxic.  It is metabolized in vivo to 2,4-dinitrophenol (DNP), but other details of its metabolism or pharmacokinetics are unknown.  There are considerable toxicity data for DNP, a known un-coupler of oxidative phosphorylation among other things, and these data may further inform regarding the safety of DNAN.  In humans, DNAN was a component of louse powder (prior to DDT) with no reported safety concerns.  However, its handling and use as a munition component presents a potential occupational hazard by both inhalation and dermal routes of exposure.  Considering both DNAN and DNP toxicity endpoints, the recommended Workplace Environmental Exposure limit for DNAN is 0.1 mg/m 2 (8-h time weighted average).

  4. Ocular side effects following intravitreal injection therapy for retinoblastoma: a systematic review.

    PubMed

    Smith, Stephen J; Smith, Brian D; Mohney, Brian G

    2014-03-01

    To describe the ocular side effects in patients receiving intravitreal injection therapy (IViT) for retinoblastoma. PubMed (1946-present), Scopus (all years), Science Citation Index (1900-present) and Conference Proceedings Citation Index-Science (1990-present) electronic databases were searched to identify all published reports of therapeutic intravitreal injections for retinoblastoma in humans. Ten studies with original IViT ocular side effect data were included in this systematic review. In these combined reports, a total of 1287 intravitreal injections were given to 306 eyes of 295 patients, with a mean follow-up of 74.1 months. Two hundred sixty-one (88.5%) patients received comparatively standard melphalan IViT doses (8-30 mcg). Ocular side effects occurred in 38 patients (17 significant, 21 minor). The proportion of patients experiencing potentially significant ocular side effects following standard melphalan IViT regimens was 0.031 (8/261; 95% CI 0.013 to 0.06). The side effects of these eight included iris atrophy in three, two each with chorioretinal atrophy and vitreous haemorrhage and one with retinal detachment. Of the other nine patients with significant complications, five experienced sight-threatening complications following dramatic dose escalations (four with melphalan, one with thiotepa), three experienced complications that are commonly associated with concurrent therapies given to these patients and one had a retinal detachment. Of the 61 patients receiving IViT via safety-enhancing injection techniques, all six significant side effects were either attributed to the therapeutic dose or confounded by concurrent treatments. Significant ocular complications following IViT for retinoblastoma are uncommon, and this risk may be reduced further by the use of careful injection technique and standard dosing regimens. Care must be taken in the dosing of intravitreal treatments to avoid potentially irreversible vision loss.

  5. Mechanistic-based non-animal assessment of eye toxicity: Inflammatory profile of human keratinocytes cells after exposure to eye damage/irritant agents.

    PubMed

    da Silva, Artur Christian Garcia; Chialchia, Adrienny Rodrigues; de Ávila, Renato Ivan; Valadares, Marize Campos

    2018-06-25

    Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC 20 ) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC 20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1β, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1β production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1β were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1β measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye toxicity, differentiating damage from irritation potential. Copyright © 2018. Published by Elsevier B.V.

  6. Subchronic (26- and 52-week) toxicity and irritation studies of a novel microbicidal gel formulation containing sodium lauryl sulfate in animal models.

    PubMed

    Piret, Jocelyne; Laforest, Geneviève; Bussières, Martin; Bergeron, Michel G

    2008-03-01

    The safety of an ethylene oxide/propylene oxide gel formulation containing sodium lauryl sulfate (2%, w/w), that could be a potent candidate as a topical microbicide, has been evaluated. More specifically, the subchronic (26- and 52-week) toxicity of the formulation when applied intravaginally as well as its irritating potential for the rectal, penile, eye, skin and buccal mucosa have been examined in animal models. The results showed that the vaginal administration of the gel formulation containing sodium lauryl sulfate once and twice daily (with doses 12 +/- 2 h apart) for 26 weeks to rats and for 52 weeks to rabbits induced slight to moderate histopathological alterations. When the formulation was applied intrarectally to male and female rabbits once and twice daily (with doses 12 +/- 2 h apart) for 14 days, no macroscopic or microscopic changes were reported. For both vaginal and rectal dosing, no effect was seen on the haematology, coagulation and serum chemistry parameters as well as on the body weight of animals and the relative organ weights. Other sporadic macroscopic and histopathological findings were incidental in origin and of no toxicological significance. The gel formulation containing sodium lauryl sulfate was considered as mildly irritating for the penile mucosa of rabbits, non-irritating for the eye of rabbits, mildly irritating for the skin in a rabbit model and non-irritating for the hamster cheek pouch. It is suggested that the gel formulation containing sodium lauryl sulfate is safe for most tissues that could be exposed to the product under normal use.

  7. Ocular toxoplasmosis: recent aspects of pathophysiology and clinical implications.

    PubMed

    Pleyer, Uwe; Schlüter, Dirk; Mänz, Martin

    2014-01-01

    Toxoplasma gondii is an extremely successful opportunistic parasite which infects approximately one third of the human population worldwide. The impact of this parasite on human health becomes particularly manifest in congenital damage with infection and subsequent inflammation of neuronal tissues including the retina. Although advances in our understanding could be achieved in ocular toxoplasmosis, large gaps still exist on factors influencing the epidemiology and pathophysiology of this potentially blinding disease. We are only at the beginning of understanding the complex biology of this parasite and its mechanisms of invasion, virulence and interaction with the host's immune response. Since it is a preventable cause of blindness, it is necessary to assess factors that have the potential to control this disease in the future. This mini review will focus on recent advances in postnatal acquired ocular infection and the factors that may influence its prevalence and functional outcome. © 2014 S. Karger AG, Basel.

  8. Ocular Fundus Photography as an Educational Tool.

    PubMed

    Mackay, Devin D; Garza, Philip S

    2015-10-01

    The proficiency of nonophthalmologists with direct ophthalmoscopy is poor, which has prompted a search for alternative technologies to examine the ocular fundus. Although ocular fundus photography has existed for decades, its use has been traditionally restricted to ophthalmology clinical care settings and textbooks. Recent research has shown a role for nonmydriatic fundus photography in nonophthalmic settings, encouraging more widespread adoption of fundus photography technology. Recent studies have also affirmed the role of fundus photography as an adjunct or alternative to direct ophthalmoscopy in undergraduate medical education. In this review, the authors examine the use of ocular fundus photography as an educational tool and suggest future applications for this important technology. Novel applications of fundus photography as an educational tool have the potential to resurrect the dying art of funduscopy. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Ocular sports injuries: the current picture

    PubMed Central

    Barr, A; Baines, P; Desai, P; MacEwen, C

    2000-01-01

    Objectives—To determine the recent incidence of eye injury due to sport in Scotland, identify any trend, and establish which sports are responsible for most injury? The type of injury and final visual outcome is also evaluated. Methods—A prospective observational study of ocular injuries sustained during sport was performed over a one year period. Only patients requiring hospital admission were included. Data were collected on a standardised proforma and entered into a central database. Patients were followed up for at least three months. Results—Of 416 patients admitted because of ocular injury, 52 (12.5%) resulted from playing a sport. Although all racquet sports together accounted for 47.5% of these injuries, football was the single most common sport associated with ocular trauma, being responsible for 32.5% of cases. The most common clinical finding was macroscopic hyphaema occurring in 87.5% of patients. Overall the final visual acuity was 6/6 in 92.5% of patients. Conclusions—The incidence of eye injury due to sport at 12.5% is lower than previously reported, suggesting a change in the pattern of ocular trauma. Football is the single most common cause of ocular injury from sport in Scotland, but the wearing of protective headgear would be difficult to instigate. The incidence of hyphaema in sport related ocular trauma (87.5%) is almost double that of all ocular injury (47.8%), so the potential for serious visual loss as the result of a sports injury should not be underrated. Ophthalmologists have a role in protecting this young population at risk by actively encouraging the design and use of protective eyewear. Key Words: eye injury; ocular trauma; hyphaema; protective eyewear PMID:11131235

  10. Preparation and evaluation of a timolol maleate drug-resin ophthalmic suspension as a sustained-release formulation in vitro and in vivo.

    PubMed

    Qin, Fuhong; Zeng, Li; Zhu, Yongtao; Cao, Jingjing; Wang, Xiaohui; Liu, Wei

    2016-01-01

    The aim of this work was to assess the performance of resin as an ocular delivery system. Timolol maleate (TM) was chosen as the model drug and an ion exchange resin (IER) as the carrier. The drug-resin complex was prepared using an oscillation method and then characterized regarding particle size, zeta potential, morphology, and drug content. After in vitro drug release study and corneal permeation study were performed, in vivo studies were performed in New Zealand albino rabbits using a suspension with particles sized 4.8 ± 1.2 μm and drug loading at 43.00 ± 0.09%. The results indicate that drug released from the drug-resin ophthalmic suspension permeated the cornea and displayed a sustained-release behavior. Drug levels in the ocular tissues after administration of the drug-resin ophthalmic suspension were significantly higher than after treatment with an eye drop formulation but were lower in body tissues and in the plasma. In conclusion, resins have great potential as effective ocular drug delivery carriers to increase ocular bioavailability of timolol while simultaneously reducing systemic drug absorption.

  11. Surgical Reconstruction of Ocular Surface Tumors Using Fibrin Sealant Tissue Adhesive.

    PubMed

    Queiroz de Paiva, Aline Roseane; Abreu de Azevedo Fraga, Larissa; Torres, Virgínia Laura Lucas

    2016-10-01

    To evaluate the surgical outcomes of ocular surface reconstruction in corneal-conjunctival tumors using fibrin tissue adhesive. A prospective noncomparative study was performed between May 2013 and February 2015. Patients were submitted to routine surgical procedure for corneal-conjunctival tumor excision followed by amniotic membrane graft transplantation using fibrin tissue adhesive (Evicel®, Omrix Biopharmaceuticals Ltd., Israel). Results were assessed on the 1st, 7th, 15th and 30th postoperative days to analyze subjective complaints, adhesiveness and positioning of the graft, potential complications and recurrences. Twenty-five eyes were analyzed (male, 14). The diagnosis after the treatment was categorized as squamous cell neoplasia, dysplasia, actinic keratosis, squamous papilloma and compound melanocytic nevus. Few significant symptoms were reported, such as mild hyperemia and ocular dyscomfort. One case developed a conjunctival granuloma which regressed after topical treatment. All grafts were successful with no displacements or retraction postoperatively. There was no clinical recurrence of the tumor in a mean time of follow-up of 11 months. Fibrin tissue adhesive is safe and effective in the surgery of ocular surface tumor. In this series, sutureless amniotic membrane transplantation using fibrin glue has the potential to shorten the surgical time, mitigate inflammation postoperatively and improve patient discomfort.

  12. Nano vesicular lipid carriers of angiotensin II receptor blocker: Anti-hypertensive and skin toxicity study in focus.

    PubMed

    Ahad, Abdul; Aqil, Mohd; Kohli, Kanchan; Sultana, Yasmin; Mujeeb, Mohd

    2016-05-01

    Nanoethosomal carriers of valsartan have been previously prepared, characterized and optimized. A gel formulation of valsartan vesicular lipid carriers was composed of Carbopol(®) (1% w/w), polyethylene glycol-400 (15% w/w) and triethanolamine (0.5% w/w). The influence of the valsartan nanoethosomal formulation developed on the blood pressure of experimental hypertensive rats, and its potential for skin irritation, are presented in this report. The experimental rats were divided into three groups; the control group received no treatment (Group A). Group B was administered methyl prednisolone acetate (20 mg/kg/week) for two weeks (hypertensive control). Group C received methyl prednisolone acetate, followed by administration of the valsartan ethosomal formulation. The blood pressure of the rats was measured using a non-invasive rat blood pressure instrument based on the tail-cuff technique. The statistical analysis was performed using GraphPad InStat 3 software. The treatment group showed a significant (P < 0.05) and constant fall in blood pressure, for up to 48 h. The valsartan ethosomal formulation was found to be effective, with a 34.11% reduction in blood pressure. The formulation's potential for skin irritation was assessed by the Draize irritation score test, which ruled out the possibility of any skin irritation caused by application of the formulation in rats. Our results suggest that nanoethosomes are efficient carriers for transdermal delivery of valsartan, for the management of hypertension.

  13. Rapid and selective removal of preservative from ophthalmic formulations during eyedrops instillation.

    PubMed

    Hsu, Kuan-Hui; Chauhan, Anuj

    2015-11-01

    About 70% of eyedrops contain benzalkonium chloride (BAK) as a preservative to prevent the growth of microorganisms. While preservatives are mandated to maintain sterility, many patients exhibit irritation and toxicity to such compounds. We propose to mitigate the ocular toxicity in the ocular formulations without compromising sterility by designing a device that can be incorporated into an eyedrops bottle to selectively remove the preservatives during the process of drop instillation. Here, we specifically focus on macroporous poly(2-hydroxyethyl methacrylate) (pHEMA) gel due to its excellent biocompatibility and high partition coefficient for BAK. In addition to specific selectivity for BAK, the device also requires high hydraulic permeability to allow drop dispensing without excessive pressure drop. The pHEMA monolith can remove nearly 100% of contained BAK from a 25 ml, 0.012% BAK solution with negligible uptake of the hydrophilic drugs such as timolol and dorzolamide. The filter, however, had to be pre-equilibrated with hydrophobic drugs to reach a high separation of BAK without reducing the concentration of the active drug. The average hydraulic permeability of the filter was 0.025 Darcy, which is about 5-fold lower than the ideal value. Incorporation of a pHEMA macroporous gel into an eyedrops bottle can virtually eliminate the exposure of the eyes to the preservatives without compromising the sterility. Our novel design can eliminate the preservative induced toxicity from eyedrops thereby impacting hundreds of millions of patients with chronic ophthalmic diseases such as glaucoma and dry eyes. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Ocular autofluorescence in diabetes mellitus. A review.

    PubMed

    Calvo-Maroto, Ana M; Perez-Cambrodi, Rafael J; Garcia-Lazaro, Santiago; Ferrer-Blasco, Teresa; Cerviño, Alejandro

    2016-09-01

    Diabetes mellitus is a metabolic disease with a considerable impact on healthcare owing to its increased prevalence and high mortality rate. Structural, morphological, and physiological changes in each of the ocular components have been described in detail. Autofluorescence has been described as a good indicator of metabolic activity. The aim of the present review is to provide an overview of ocular endogenous fluorophores in the cornea, the crystalline lens, and the retinal pigment epithelium, the effects of diabetes mellitus and therefore the potential of autofluorescence assessment for screening and monitoring changes in diabetic patients. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  15. A double-blind, randomized, bilateral comparison of skin irritancy following application of the combination acne products clindamycin/tretinoin and benzoyl peroxide/adapalene.

    PubMed

    Goreshi, Renato; Samrao, Aman; Ehst, Benjamin D

    2012-12-01

    The use of topical medications for acne vulgaris is often limited by their irritant properties. Newer combination preparations are available and offer convenience, but irritant potential may still be a hindrance, perhaps more so with the combination of 2 agents. Few studies have compared these formulations directly for tolerability. We sought to compare the tolerability of 2 combination topical acne products, clindamycin 1.2%-tretinoin 0.025% (CLIN/RA) gel and benzoyl peroxide 2.5%-adapalene 0.1% (BPO/ADA) gel. CLIN/RA and BPO/ADA were applied daily to opposite sides of a subject's face for 21 days in a double-blinded fashion. Investigators' Global Assessments and study subject self-assessments of burning/stinging, itching, erythema, and dryness/scaling were collected. Transepidermal water loss (TEWL) was also measured as an objective measure of skin irritation. A mixed model analysis and repeated-measures analysis of variance were used to compare outcomes for both acne formulations. CLIN/RA produced significantly less burning/stinging than BPO/ADA (P<.001) as well as significantly less pruritus than BPO/ ADA (P<.001). BPO/ADA caused significantly more TEWL than CLIN/RA (P=.005). There was no significant difference in the amount of erythema or the amount of dryness/scaling caused by either formulation. CLIN/RA produced significantly less skin irritancy and TEWL than BPO/ADA.

  16. CON4EI: Selection of the reference chemicals for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Adriaens, E; Alépée, N; Kandarova, H; Drzewieckac, A; Gruszka, K; Guest, R; Willoughby, J A; Verstraelen, S; Van Rompay, A R

    2017-10-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Reprint of "CON4EI: Selection of the reference chemicals for hazard identification and labelling of eye irritating chemicals".

    PubMed

    Adriaens, E; Alépée, N; Kandarova, H; Drzewieckac, A; Gruszka, K; Guest, R; Willoughby, J A; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. In the past, several prospective and retrospective validation studies have taken place in the area of serious eye damage/eye irritation testing. Success in terms of complete replacement of the regulatory in vivo Draize rabbit eye test has not yet been achieved. A very important aspect to ensure development of successful alternative test methods and/or strategies for serious eye damage/eye irritation testing is the selection of appropriate reference chemicals. A set of 80 reference chemicals was selected for the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project, in collaboration with Cosmetics Europe, from the Draize Reference Database published by Cosmetics Europe based on key criteria that were set in their paper (e.g. balanced by important driver of classification and physical state). The most important goals of the CON4EI project were to identify the performance of eight in vitro alternative tests in terms of driver of classification and to identify similarities/differences between the methods in order the build a successful testing strategy that can discriminate between all UN GHS categories. This paper provides background on selection of the test chemicals. Copyright © 2018. Published by Elsevier Ltd.

  18. Cumulative irritation potential of topical retinoid formulations.

    PubMed

    Leyden, James J; Grossman, Rachel; Nighland, Marge

    2008-08-01

    Localized irritation can limit treatment success with topical retinoids such as tretinoin and adapalene. The factors that influence irritant reactions have been shown to include individual skin sensitivity, the particular retinoid and concentration used, and the vehicle formulation. To compare the cutaneous tolerability of tretinoin 0.04% microsphere gel (TMG) with that of adapalene 0.3% gel and a standard tretinoin 0.025% cream. The results of 2 randomized, investigator-blinded studies of 2 to 3 weeks' duration, which utilized a split-face method to compare cumulative irritation scores induced by topical retinoids in subjects with healthy skin, were combined. Study 1 compared TMG 0.04% with adapalene 0.3% gel over 2 weeks, while study 2 compared TMG 0.04% with tretinoin 0.025% cream over 3 weeks. In study 1, TMG 0.04% was associated with significantly lower cumulative scores for erythema, dryness, and burning/stinging than adapalene 0.3% gel. However, in study 2, there were no significant differences in cumulative irritation scores between TMG 0.04% and tretinoin 0.025% cream. Measurements of erythema by a chromameter showed no significant differences between the test formulations in either study. Cutaneous tolerance of TMG 0.04% on the face was superior to that of adapalene 0.3% gel and similar to that of a standard tretinoin cream containing a lower concentration of the drug (0.025%).

  19. Characteristics of non-vitreoretinal ocular injury in child maltreatment: a systematic review.

    PubMed

    Betts, T; Ahmed, S; Maguire, S; Watts, P

    2017-08-01

    PurposeTo identify the spectrum of non-vitreoretinal ocular injury due to child maltreatment.MethodsAll language search of MEDLINE, PsychINFO, EMBASE, AMED, Web of Science, and CINAHL databases, 1950-2015, was conducted. explicit confirmation of injury aetiology, age <18 years, examination conducted by an ophthalmologist. Exclusion: post-mortem data, organic diseases, review articles. Standardised critical appraisal and narrative synthesis was conducted of included publications by two independent reviewers.ResultsOf 1492 studies identified, 153 full texts were assessed, 49 underwent full review, resulting in five included studies: three case series and two case reports. The 26 included cases describe a wide variety of ocular, facial and skeletal injuries occurring as a consequence of child maltreatment. Ocular signs included periorbital oedema, chemosis, injection, abrasion, hyphaema, and cataract. Of interest all children that had suffered physical abuse with ocular injury had subconjunctival haemorrhages. Children presenting with abusive ocular injuries had a mean age of 13.9 months (range 1-68), while those who suffered violent corporal punishment were considerably older (mean 96 months). All cases, apart from severe corporal punishment, underwent screening for occult fractures, but neuroimaging only apparent in 2/5 eligible cases.ConclusionAlthough, the face is the most common site of abusive injury, there is a paucity of high-quality data on non-vitreoretinal ocular abusive injury. Thus, while subconjunctival haemorrhages are a potential sentinel injury of maltreatment, and may warrant further evaluation, the lack of large-scale published data limits our ability to highlight further specific characteristics of non-vitreoretinal ocular injury indicative of child abuse.

  20. Irritable Bowel Syndrome

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español Irritable Bowel Syndrome KidsHealth / For Teens / Irritable Bowel Syndrome What's in ... intestinal disorder called irritable bowel syndrome. What Is Irritable Bowel Syndrome? Irritable bowel syndrome (IBS) is a common intestinal ...

  1. Sensory Effects of Menthol and Nicotine in an E-Cigarette

    PubMed Central

    Rosbrook, Kathryn

    2016-01-01

    Introduction: Despite the longstanding use and popularity of menthol as a flavorant in tobacco products, its sensory interactions with inhaled nicotine have never been measured independently of the other irritants in tobacco smoke. We therefore measured the perception of menthol in an E-cigarette with the primary goal of assessing its analgesic effect on the sensory irritation produced by inhaled nicotine. Methods: Adult cigarette smokers sampled aerosolized E-liquids containing five different concentrations of nicotine with 0%, 0.5%, or 3.5% l-menthol, as well as two commercial menthol flavors with and without nicotine. For each of the E-liquids participants used a labeled magnitude scale to rate the Overall Sensation intensity, Coolness/Cold, and Irritation/Harshness they experienced, and a Labeled Hedonic Scale to indicate how much they liked/disliked the overall flavor. Results: The main findings were that (1) perceived Irritation/Harshness was unaffected by a low (0.5%) menthol concentration, whereas a high menthol concentration (3.5%) led to higher perceived Irritation/Harshness at low nicotine concentrations but to lower Irritation/Harshness at the highest nicotine concentration (24mg/ml); (2) a commercial Menthol–Mint flavor produced similar results; (3) nicotine tended to enhance rather than suppress sensations of Coolness/Cold; and (4) menthol tended to slightly increase liking independently of nicotine concentration. Conclusion: In addition to adding a sensation of coolness, menthol can reduce perceived airway irritation and harshness produced by inhalation when nicotine concentration is high, and contributes to the sensory impact of E-liquids when nicotine concentration is low. Implications: The evidence presented here indicates that menthol can potentially improve the appeal of E-cigarettes not only via its coolness and minty flavor, but also by reducing the harshness from high concentrations of nicotine. As the first direct demonstration of an analgesic effect of menthol on inhaled nicotine in humans, these data also have implications for the role of menthol flavors in other inhaled tobacco products. PMID:26783293

  2. Abnormal Vestibulo-Ocular Reflexes in Autism: A Potential Endophenotype

    DTIC Science & Technology

    2013-06-01

    Annual Report for 15 May 2012 – 14 May 2013 8 Table 5. Summary of Gaze Evoked Nystagmus Tests (no differences between groups) Target...abnormalities of vestibulo-ocular reflexes (VOR) in Autism Spectrum Disorder (ASD). Specific Aim 1: Characterize horizontal VOR post-rotary nystagmus ...without optokinetic feedback using a velocity step test. We hypothesize that in ASD vertical eye movement intrusions during horizontal nystagmus will

  3. Vision-Threatening Behcet's Disease: Severity of Ocular Involvement Predictors

    PubMed Central

    Hussein, Mohammed A.; Dahab, Ahmed A.

    2018-01-01

    Purpose To examine and spot systemic findings commonly associated with a serious form of ocular Behcet's disease. This could potentially help ophthalmologists categorize their patients based on future risk and plan treatment accordingly. Subjects and Methods The data of 249 patients with Behcet's disease were examined thoroughly. Correlations between systemic and ocular findings were recorded. Patients were further subgrouped by the authors as having a vision-threatening form of the disease or not. Regression analysis was done to spot predictors for a vision-threatening form of the disease. Results The presence of systemic vasculitis and oral and genital ulcers in a patient with Behcet's disease was found to be associated with a milder form of ocular affection or none at all and vice versa. Certain correlations between findings were also found. Conclusion Certain findings in Behcet's disease may act as predictors for the severity of ocular affection. Directing our attention to these factors by the internist and ophthalmologist can help plan the frequency of follow-up as well as the aggressiveness of treatment in patients with Behcet's disease. PMID:29854430

  4. Slit2 signaling through Robo1 and Robo2 is required for retinal neovascularization

    PubMed Central

    Rama, Nicolas; Dubrac, Alexandre; Mathivet, Thomas; Chárthaigh, Róisín-Ana Ní; Genet, Gael; Cristofaro, Brunella; Pibouin-Fragner, Laurence; Ma, Le; Eichmann, Anne; Chédotal, Alain

    2016-01-01

    Ocular neovascular diseases are a leading cause of blindness. Vascular endothelial growth factor (VEGF) blockade improves vision, but not all individuals respond to anti-VEGF treatment, making additional means to prevent neovascularization necessary. Slit-family proteins (Slits) are ligands of Roundabout (Robo) receptors that repel developing axons in the nervous system. Robo1 expression is altered in ocular neovascular diseases, and previous in vitro studies have reported both pro- and anti-angiogenic effects of Slits. However, genetic evidence supporting a role for Slits in ocular neovascularization is lacking. Here we generated conditional knockout mice deficient in various Slit and Robo proteins and found that Slit2 potently and selectively promoted angiogenesis via Robo1 and Robo2 in mouse postnatal retina and in a model of ocular neovascular disease. Mechanistically, Slit2 acting through Robo1 and Robo2 promoted the migration of endothelial cells. These receptors are required for both Slit2- and VEGF-induced Rac1 activation and lamellipodia formation. Thus, Slit2 blockade could potentially be used therapeutically to inhibit angiogenesis in individuals with ocular neovascular disease. PMID:25894826

  5. Primary Dermal Irritation Potential of Components of the M-258A-1 Decontamination Kit (Study 3).

    DTIC Science & Technology

    1981-09-01

    PROJECT: Medical Defense Against Chemical Agents 612772.875. GLP STUDY NUMBER: 81019 STUDY DIRECTOR: LTC (P) John T. Fruin, DVM, PhD, VC, Diplomate...hereby certify that in relation to LAIR GLP study 81019 the following inspections were made: 11 June 1981 15 June 1981 16 June 1981 18 June 1981...gryI___________- APPENDIX A-3 Suiu:c ria of Prir-ary SkiT: Irritation Test Data GLP St Jv No. 81019 Chemica1 ;lanme Conr Solvent :Amt AoI ied Date of

  6. [Anophthalmia and microphthalmia requires multidisciplinary care. Many of the children also have other medical problems].

    PubMed

    Jugård, Ylva; Odersjö, Marie; Topa, Alexandra; Lindgren, Gun; Andersson Grönlund, Marita

    2015-07-13

    Anophthalmia/microphthalmia (A/M) are rare congenital eye malformations. Early intervention with ocular prosthesis can stimulate orbital growth and prevent facial asymmetry. We reviewed medical records from 18 individuals with A/M (0.8-31 years) treated with ocular prosthesis at Sahlgrenska University Hospital between 2000 and 2012. A majority had other ocular findings. Seven had subnormal visual acuity in the fellow eye, one third were in contact with vision support services and half of the group wore glasses. Eleven individuals had extra-ocular findings such as cardiac defect, hearing impairment and neuropsychiatric disorders, possibly indicating syndromic conditions. We suggest that investigation of A/M children should include ultrasound of the eye, optionally visual evoked potential and magnetic resonance imaging of the CNS. The ophthalmologist should initiate treatment with prosthesis, pediatric assessment, hearing tests and genetic counseling, but should also monitor visual development of the fellow eye.

  7. Calorie restriction (CR) and CR mimetics for the prevention and treatment of age-related eye disorders.

    PubMed

    Kawashima, Motoko; Ozawa, Yoko; Shinmura, Ken; Inaba, Takaaki; Nakamura, Shigeru; Kawakita, Tetsuya; Watanabe, Mitsuhiro; Tsubota, Kazuo

    2013-10-01

    The morbidity of ocular diseases, including macular degeneration, diabetic retinopathy, and dry eye disease, has been gradually increasing worldwide. Because these diseases develop from age-associated ocular dysfunctions, interventions against the aging process itself may be a promising strategy for their management. Among the several approaches to interrupt aging processes, calorie restriction (CR) has been shown to recover and/or slow age-related functional declines in various organs, including the eye. Here, we review interventions against the aging process as potential therapeutic approaches to age-related ocular diseases. The effects of CR and CR mimetics in animal models of age-related eye diseases are explored. Furthermore, we discuss the possibilities of expanding this research to prospective studies to elucidate the molecular mechanisms by which CR and/or CR mimetics preserve ocular functions. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  8. "Johnny Poppers": a cause of serious ocular injury.

    PubMed

    MacAndie, K; Kyle, P

    1998-07-01

    The causes of blunt ocular trauma are many and diverse. We present two cases of ocular injury caused by an unusual form of weapon called a "Johnny Popper". There follows a theoretical and experimental evaluation of the velocity of the projectiles fired by this device. A Johnny Popper was constructed under expert guidance. The elastic properties of the device were measured and this allowed calculation of a theoretical exit velocity of the projectiles fired. The weapon was subsequently fired under test conditions which permitted the exit velocity of the projectiles fired to be measured directly. The theoretical velocity of the projectiles was calculated as 80 ms-1 and the experimentally measured velocity was 57 ms-1. Johnny Poppers are a previously undescribed and unique form of home made weapon. They are intended for playful mischief, but have the potential to cause serious ocular trauma.

  9. Plasma Rich in Growth Factors for the Treatment of Ocular Surface Diseases.

    PubMed

    Anitua, Eduardo; Muruzabal, Francisco; de la Fuente, María; Merayo, Jesús; Durán, Juan; Orive, Gorka

    2016-07-01

    The purpose of this work is to describe and review the technology of plasma rich in growth factors (PRGF), a novel blood derivative product, in the treatment of ocular surface disorders. To demonstrate the importance of this technology in the treatment of ocular pathologies, a thorough review of the preclinical and clinical literature results obtained following use of the different therapeutic formulations of PRGF was carried out. A literature search for applications of PGRF plasma in the ophthalmology field was carried out using the PubMed database. PRGF involves the use of patient's own biologically active proteins, growth factors, and biomaterial scaffolds for therapeutic purposes. This procedural technology is gaining interest in regenerative medicine due to its potential to stimulate and accelerate the tissue healing processes. The versatility and biocompatibility of this technology opens the door to a personalized medicine on ocular tissue regeneration. This review discusses the state of the art of the new treatments and technologies developed to promote ocular surface tissue regeneration. The standardized protocol that has been developed to source eye drops from PRGF technology is also described. The preclinical research, together with the most relevant clinical applications are summarized and discussed. The preliminary results suggest that the use of PRGF to enhance ocular tissue regeneration is safe and efficient.

  10. Tandem Repeated Irritation Test (TRIT) Studies and Clinical Relevance: Post 2006.

    PubMed

    Reddy, Rasika; Maibach, Howard

    2018-06-11

    Single or multiple applications of irritants can lead to occupational contact dermatitis, and most commonly irritant contact dermatitis (ICD). Tandem irritation, the sequential application of two irritants to a target skin area, has been studied using the Tandem Repeated Irritation Test (TRIT) to provide a more accurate representation of skin irritation. Here we present an update to Kartono's review on tandem irritation studies since 2006 [1]. We surveyed the literature available on PubMed, Embase, Google Scholar, and the UCSF Dermatology library databases since 2006. The studies included discuss the tandem effects of common chemical irritants, organic solvents, occlusion as well as clinical relevance - and enlarge our ability to discern whether multiple chemical exposures are more or less likely to enhance irritation.

  11. Sensory irritation structure-activity study of inhaled aldehydes in B6C3F1 and Swiss-Webster mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinhagen, W.H.; Barrow, C.S.

    1984-03-15

    The sensory irritation potential of a series of saturated and unsaturated aliphatic and cyclic aldehydes was investigated in B6C3F1 and Swiss-Webster mice. With the reflex decrease in respiratory rate as the endpoint response, alpha, beta-unsaturated aliphatic aldehydes yielded RD/sub 50/ values (concentration which elicits a 50% decrease in respiratory rate) ranging from 1 to 5 ppm while saturated aliphatic aldehydes with two or more carbons produced RD/sub 50/ values from 750 to 4200 ppm. Cyclic aldehydes produced intermediate RD/sub 50/ values which ranged from 60 to 400 ppm. No statistically significant differences were found between concentration-response curves of B6C3F1 andmore » Swiss-Webster mice. Saturated aliphatic aldehydes with two or more carbons were nearly 1000 times less potent than formaldehyde. Although the mechanisms responsible for stimulation of trigeminal nerve endings by airborne chemicals are poorly understood, several hypotheses may help to explain the differences seen in this study. For example, the sensory irritation potency of the saturated aliphatic aldehydes diminished with their reported dehydration constants which may determine the degree to which these aldehydes crosslink with receptor proteins. The sensory irritation potency of acrolein and crotonaldehyde was probably due to 1,2 or 1,4 addition reactions. Additionally, molecular conformation and a recently published physical mechanism may contribute to sensory irritation responses, particularly for the less reactive aldehydes. Tentative threshold limit values (TLVs), based upon prevention of sensory irritation, were extrapolated from the RD/sub 50/ values of Swiss-Webster mice. With the exception of crotonaldehyde, good agreement was found with currently published TLVs.« less

  12. Safety and toxicological evaluation of a novel anti-obesity formulation LI85008F in animals.

    PubMed

    Krishnaraju, A V; Sundararaju, D; Srinivas, P; Rao, C V; Sengupta, K; Trimurtulu, G

    2010-02-01

    LI85008F is a novel synergistic composition of Moringa oleifera, Murraya koenigi, and Curcuma longa. These herbs are well recognized and widely used in ayurvedic system of medicine for treating a variety of diseases and are also have been used for culinary purposes for thousands of years. LI85008F inhibits preadipocyte differentiation and potentiates lipid breakdown in mature adipocytes. In diet-induced obese rats, LI85008F significantly reduced weight gain and improved serum adiponectin levels. These findings motivated the authors to determine the broad-spectrum safety of LI85008F. Acute oral toxicity, acute dermal toxicity, primary skin irritation, primary eye irritation, and dose-dependent 28-day sub-acute toxicity studies were conducted. The acute oral LD50 of LI85008F was greater than 5000 mg/kg in female SD rats and no changes in body weight or adverse effects were observed following necropsy. Acute dermal LD50 of LI85008F was greater than 2000 mg/kg. LI85008F was classified as non-irritating to skin in a primary dermal irritation study conducted using New Zealand Albino rabbits. LI85008F caused minimal irritation to eyes in a primary eye irritation test conducted on New Zealand Albino rabbits. A dose-dependent 28-day sub-acute toxicity study demonstrated no significant changes in selected organ weights. Evaluations on hematology, clinical chemistry, and histopathology did not show any significant adverse changes. The NOAEL of LI85008F was found to be greater than 2500 mg/kg body weight. These results demonstrate the broad spectrum safety of LI85008F in animal models.

  13. Tretinoin-loaded liposomal formulations: from lab to comparative clinical study in acne patients.

    PubMed

    Rahman, Salwa Abdel; Abdelmalak, Nevine Shawky; Badawi, Alia; Elbayoumy, Tahany; Sabry, Nermeen; El Ramly, Amany

    2016-05-01

    Topical tretinoin is the most commonly used retinoid for acne. However, its irritative potential on the applied area and the barrier properties of the stratum corneum limit its use. The objective of the present study was to formulate tretinoin liposomal gel to obtain a formula with lower skin irritation potential and greater clinical effect. A statistical 2(4) factorial design was adopted. Sixteen formulae prepared and were properly evaluated. A candidate formula (F13G) prepared with 0.025% tretinoin, phospholipid- cholesterol-dicetylphosphate (9:1:0.01) and incorporated in 1% carbopol gel was selected for skin irritation test. Clinical study was conducted on acne patients and compared to marketed product. All liposomes formulations were spherical in shape. The addition of cholesterol in the film hydration method significantly decreased the vesicle size, and increased the percentage of incorporation efficiency at (p < 0.05). The presence of dicetylphosphate significantly increased drug release but did not affect the percentage of incorporation efficiency and vesicle size. The results of the clinical study in acne patients revealed that F13G showed significantly higher efficacy when compared to marketed product (p < 0.05).

  14. Formulation and Characterization of Benzoyl Peroxide Gellified Emulsions

    PubMed Central

    Thakur, Naresh Kumar; Bharti, Pratibha; Mahant, Sheefali; Rao, Rekha

    2012-01-01

    The present investigation was carried out with the objective of formulating a gellified emulsion of benzoyl peroxide, an anti-acne agent. The formulations were prepared using four different vegetable oils, viz. almond oil, jojoba oil, sesame oil, and wheat germ oil, owing to their emollient properties. The idea was to overcome the skin irritation and dryness caused by benzoyl peroxide, making the formulation more tolerable. The gellified emulsions were characterized for their homogeneity, rheology, spreadability, drug content, and stability. In vitro permeation studies were performed to check the drug permeation through rat skin. The formulations were evaluated for their antimicrobial activity, as well as their acute skin irritation potential. The results were compared with those obtained for the marketed formulation. Later, the histopathological examination of the skin treated with various formulations was carried out. Formulation F3 was found to have caused a very mild dysplastic change to the epidermis. On the other hand, the marketed formulation led to the greatest dysplastic change. Hence, it was concluded that formulation F3, containing sesame oil (6%w/w), was the optimized formulation. It exhibited the maximum drug release and anti-microbial activity, in addition to the least skin irritation potential. PMID:23264949

  15. How irritating: the role of TRPA1 in sensing cigarette smoke and aerogenic oxidants in the airways

    PubMed Central

    Simon, Sidney A.; Liedtke, Wolfgang

    2008-01-01

    Airway irritants cause a variety of lung pathologies. Two separate studies, the first recently reported in the JCI by Bessac et al. and the second reported by Andrè et al. in the current issue of the JCI (see the related article beginning on page 2574), have identified irritants that activate transient receptor potential cation channel, subfamily A, member 1 (TRPA1) receptors in airway sensory neurons, resulting in neurogenic inflammation and respiratory hypersensitivity. The identification of TRPA1 activation by toxicants from cigarette smoke and polluted air, such as crotonaldehyde, acrolein, and oxidizing agents such as hydrogen peroxide, is an important finding. These two studies enhance our understanding of how pollution and cigarette smoke can damage airway function and will hopefully pave the way for the development of rational alternative therapeutics for such airway injury. PMID:18568080

  16. Allergic contact dermatitis due to urethane acrylate in ultraviolet cured inks.

    PubMed Central

    Nethercott, J R; Jakubovic, H R; Pilger, C; Smith, J W

    1983-01-01

    Seven workers exposed to ultraviolet printing inks developed contact dermatitis. Six cases were allergic and one irritant. A urethane acrylate resin accounted for five cases of sensitisation, one of which was also sensitive to pentaerythritol triacrylate and another also to an epoxy acrylate resin. One instance of allergy to trimethylpropane triacrylate accounted for the sixth case of contact dermatitis in this group of workers. An irritant reaction is presumed to account for the dermatitis in the individual not proved to have cutaneous allergy by patch tests. In this instance trimethylpropane triacrylate was thought to be the most likely irritating agent. Laboratory investigation proved urethane acrylate to be an allergen. The results of investigations of the sensitisation potentials of urethane acrylate, methylmethacrylate, epoxy acrylate resins, toluene-2,4-diisocyanate, and other multifunctional acrylic monomers in the albino guinea pig are presented. The interpretation of such predictive tests is discussed. Images PMID:6223656

  17. Diesel exhaust causing low-dose irritant asthma with latency?

    PubMed

    Adewole, Femi; Moore, Vicky C; Robertson, Alastair S; Burge, P S

    2009-09-01

    Diesel exhaust exposure may cause acute irritant-induced asthma and potentiate allergen-induced asthma. There are no previous reports of occupational asthma due to diesel exhaust. To describe occupational asthma with latency in workers exposed to diesel exhaust in bus garages. The Shield database of occupational asthma notifications in the West Midlands, UK, was searched between 1990 and 2006 for workers where diesel exhaust exposure was thought to be the cause of the occupational asthma. Those without other confounding exposures whose occupational asthma was validated by serial peak expiratory flow (PEF) analysis using Oasys software were included. Fifteen workers were identified with occupational asthma attributed to diesel exhaust. Three had validated new-onset asthma with latency. All worked in bus garages where diesel exhaust exposure was the only likely cause of their occupational asthma. Occupational asthma was confirmed by measures of non-specific reactivity and serial measurements of PEF with Oasys scores of 2.9, 3.73 and 4 (positive score > 2.5). The known non-specific irritant effects of diesel exhaust suggest that this is an example of low-dose irritant-induced asthma and that exposures to diesel exhaust in at least some bus garages are at a sufficient level to cause this.

  18. Complementary and alternative medicine for treatment of irritable bowel syndrome.

    PubMed

    Shen, Yi-Hao A; Nahas, Richard

    2009-02-01

    To review the evidence supporting selected complementary and alternative medicine approaches used in the treatment of irritable bowel syndrome (IBS). MEDLINE (from January 1966), EMBASE (from January 1980), and the Cochrane Database of Systematic Reviews were searched until March 2008, combining the terms irritable bowel syndrome or irritable colon with complementary therapies, alternative medicine, acupuncture, fiber, peppermint oil, herbal, traditional, yoga, massage, meditation, mind, relaxation, probiotic, hypnotherapy, psychotherapy, cognitive therapy, or behavior therapy. Results were screened to include only clinical trials, systematic reviews, and meta-analyses. Level I evidence was available for most interventions. Soluble fibre improves constipation and global IBS symptoms. Peppermint oil alleviates IBS symptoms, including abdominal pain. Probiotic trials show overall benefit for IBS but there is little evidence supporting the use of any specific strain. Hypnotherapy and cognitive-behavioural therapy are also effective therapeutic options for appropriate patients. Certain herbal formulas are supported by limited evidence, but safety is a potential concern. All interventions are supported by systematic reviews or meta-analyses. Several complementary and alternative therapies can be recommended as part of an evidence-based approach to the treatment of IBS; these might provide patients with satisfactory relief and improve the therapeutic alliance.

  19. 4-Day evaluation of the irritation potential of topical desoximetasone 0.25% and 0.05% spray on light-exposed skin.

    PubMed

    Patel, Nupur U; Grammenos, Alexandra; Gowda, Asha; Onikoyi, Omobola; Feldman, Steven R

    2018-06-01

    The safety and potential side effects of desoximetasone 0.25% and 0.05% sprays have not previously been studied. The primary objective of this study was to determine the irritation potential of desoximetasone 0.25%, 0.05% and vehicle sprays in response to irradiation. Thirty-four subjects were enrolled in the study, each with three study treatments (desoximetasone 0.25%, 0.05% topical sprays and vehicle) were applied to two sites each on the back of every subject, with half of the sites irradiated with filtered UV light. Dermal reactions at the test sites were evaluated using a visual scale with corresponding numerical scores that rated the degree of erythema and oedema. Desoximetasone 0.25%, 0.05%, and vehicle caused no detectable signs of phototoxicity when examined on days 3 and 4. Mean scores of desoximetasone 0.25%, 0.05% and vehicle to non-irradiated treatment areas showed no signs of irritation. Our results suggest that regular application of desoximetasone 0.25% and 0.05% topical sprays do not induce photosensitization or photoirritation. The safety of this topical spray may help with clinical management of patients using topical corticosteroids while also receiving therapeutic UV light exposure. Thus, patients can use desoximetasone sprays without concerns of side effects due to therapeutic light or sun exposure.

  20. Final report of the amended safety assessment of Dioscorea Villosa (Wild Yam) root extract.

    PubMed

    2004-01-01

    Dioscorea Villosa (Wild Yam) Root Extract is an extract of the rhizomes of the wild yam, D. villosa. A manufacturing process was described in which cut up and ground rhizomes are combined with an eluant (e.g., oleyl alcohol), the plant material precipitated with addition of a miscible solvent, washed, and redissolved in the original eluant. The extract contains glycoside and steroidal saponins (< or =0.4%), diosgenin (< or =3.5%), alkaloids, tannins, phytosterols, and starch. Levels of heavy metals, 1,4-dioxane, chloroform, methylene chloride, trichloroethylene, and benzene are reported to be below limits of detection. Although only one use was reported to the U.S. Food and Drug Administration (in a body and hand preparation), industry reported uses in body and hand creams, lotions, powders, and sprays at a concentration of 0.00001% (equivalent to 0.000002% plant solids), and in moisturizing creams, lotions, powders, and sprays at concentrations up to 15% (equivalent to 0.5% plant solids). Preparations fromD. villosaare used in herbal medicine for treatment of a variety of ailments and by the pharmaceutical industry in the preparation of steroids. Using Dioscorea Villosa (Wild Yam) Root Extract prepared via a specified process, it is possible to produce a stable extract with a narrow range of diosgenin content. The extract produced using this methodology was tested in acute and short-term toxicity tests, dermal irritation tests, a sensitization test, an ocular irritation test, a rat uterotropic assay, and genotoxicity tests. An acute oral toxicity test produced hypoactivity, piloerection, and dyspnea and a death in 1 of 10 rats at 2 g/kg using the specified extract, but no toxicity in rats given 0.5 g/kg. A dermal toxicity test using the specified extract demonstrated no acute toxicity in rats. Both a 7-day local tolerance test and a 28-day dermal toxicity test in rats produced no significant adverse effects at the maximum tested concentration of 10%. A single application of undiluted extract to the intact and abraded skin of rabbits produced sufficient irritation for the test material to be rated"irritant,"but a 10% dilution was not irritating. Undiluted extract was only mildly irritating to the conjuctiva of the rabbit eye; irritation in the iris and cornea was mild and transient. Undiluted extract was not irritating during the induction phase of a guinea pig sensitization study, nor did challenge with a 25% dilution elicit any sensitization. The specified extract at concentrations up to 500 mg/kg/day did not have any estrogenic activity in the juvenile rat uterotrophic assay. Genotoxicity assays in bacterial and mammalian systems were negative, except that Ames test strain TA 1537 was positive at one dose level using the plate incorporation method, but not using a preincubation method. Although the concentration at which the actual plant extract is used in cosmetic products is low, one of the primary safety concerns with this plant extract is the possible metabolic/endocrine activity, e.g., estrogen-like or progesterone-like activity as a result of the presence of small amounts of plant phytosterols such as diosgenin. Extracts prepared as described in this safety assessment, with an upper limit of 3.5% diosgenin, did not have any estrogenic activity, demonstrating that it is possible to produce material that does not present this specific safety concern. Although extracts from pesticide-free plants were not considered genotoxic and it was the view of the Cosmetic Ingredient Review (CIR) Expert Panel that there do not appear to be any components that could be carcinogenic, pesticide residues could raise this issue. It was urged that manufacturers limit pesticide residues to the limit previously used for lanolin of not more than 40 ppm (with not more than 10 ppm for any one residue). Based on these data, it was concluded that Dioscorea Villosa (Wild Yam) Root Extract is safe as used in cosmetic formulations. This conclusion regarding safety, however, is valid only for extracts prepared in a manner that produces a similar chemical profile as that described in this report, particularly as regards diosgenin. Extracts not prepared in a manner that produces a similar chemical profile would be considered safe if they have a similar safety test profile.

  1. Supercritical fluid-mediated liposomes containing cyclosporin A for the treatment of dry eye syndrome in a rabbit model: comparative study with the conventional cyclosporin A emulsion

    PubMed Central

    Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo

    2014-01-01

    Background The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis®) for the treatment of dry eye syndrome in rabbits. Methods Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis®-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. Results After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis®-treated group. The AUC0–24 h for rabbit’s tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis®. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis®. Conclusion These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes. PMID:25143728

  2. Efficacy and safety of spinosad and permethrin creme rinses for pediculosis capitis (head lice).

    PubMed

    Stough, Dow; Shellabarger, Susan; Quiring, John; Gabrielsen, Alvin A

    2009-09-01

    Studies compared spinosad creme rinse and permethrin lice treatment under "actual-use" conditions for pediculosis capitis (head lice). Two phase-3, multicenter, randomized, evaluator/investigator-blinded studies compared 0.9% spinosad without nit-combing to 1% permethrin with combing (according to product instructions) in 1038 males and females aged > or =6 months. Spinosad-with-combing groups were included for descriptive, noninferential purposes only. Within 391 households, youngest members having > or =3 live lice were designated primary participants. All household members with lice received the same treatment. Participants administered product 1 to 2 times during the 21-day home-use period on the basis of complete lice eradication after a single use or the presence of lice requiring a second treatment. Scalp evaluations were performed at baseline, day 7, and day 14 (and day 21 for participants treated twice). The primary end point was the proportion of lice-free primary participants 14 days after last treatment. A total of 84.6% (study 1) and 86.7% (study 2) of spinosad-treated participants were lice free versus 44.9% and 42.9% permethrin-treated participants (P < .001). Most spinosad-treated participants required 1 application, whereas most permethrin-treated participants required 2 applications. Few adverse events were reported, but those occurring were mild to moderate, including eye irritation (permethrin), ocular hyperemia, and application-site erythema/irritation (both medications). No laboratory measure changed significantly. Spinosad, which did not require nit combing, was significantly more effective than permethrin in 2 studies reflecting actual-use conditions, and most spinosad-treated participants required only 1 application. Spinosad is a more convenient and effective treatment for pediculosis capitis.

  3. Pediatric and young adult exposure to chemiluminescent glow sticks.

    PubMed

    Hoffman, Robert J; Nelson, Lewis S; Hoffman, Robert S

    2002-09-01

    Although chemiluminescent plastic rods, commonly called "glow sticks" or "light sticks," are typically considered to be minimally toxic or nontoxic, published data about exposure to these products are scarce. To test our hypothesis that exposure to chemiluminescent products is unlikely to result in significant morbidity or mortality and to describe factors associated with exposure by reviewing reports to our urban poison control center of human exposure to chemiluminescent products. Pediatric and young adult exposure to chemiluminescent products reported between January 1, 2000, and April 1, 2001, to our poison control center were evaluated with regard to demographic group, type of product involved, circumstances of exposure, symptoms, and management. Reported routes of exposure (n = 118) included ingestion (n = 108), ocular (n = 9), and dermal exposure (n = 1). Only patients exposed to chemiluminescent fluid from a leaking container reported symptoms (n = 27). Symptoms were limited to transient irritation of the exposure site, and no systemic toxicity occurred. All adults (n = 4) inadvertently ruptured or swallowed intact light sticks while at a dance club or dance party. Most exposure and all adult exposure occurred on holidays or weekends. Most incidences of exposure to chemiluminescent products involve asymptomatic ingestion of fluid that leaks from glow sticks or ingestion of an intact glow stick. Symptoms occur after exposure to chemiluminescent fluid and consist of transient irritation at the site of exposure. The clustering of reported exposure on weekends and in dance clubs and parties coupled with a lack of occupational or workplace exposure suggest that recreational use is a major contributory factor. Exposure to chemiluminescent products infrequently resulted in symptoms and the symptoms reported were minor. Exposure to chemiluminescent products as described is unlikely to cause significant morbidity or mortality.

  4. Supercritical fluid-mediated liposomes containing cyclosporin A for the treatment of dry eye syndrome in a rabbit model: comparative study with the conventional cyclosporin A emulsion.

    PubMed

    Karn, Pankaj Ranjan; Kim, Hyun Do; Kang, Han; Sun, Bo Kyung; Jin, Su-Eon; Hwang, Sung-Joo

    2014-01-01

    The objective of this study was to compare the efficacy of cyclosporin (CsA)-encapsulated liposomes with the commercially available CsA emulsion (Restasis) for the treatment of dry eye syndrome in rabbits. Liposomes containing CsA were prepared by the supercritical fluid (SCF) method consisted of phosphatidylcholine from soybean (SCF-S100) and egg lecithins (SCF-EPCS). An in vitro permeation study was carried out using artificial cellulose membrane in Franz diffusion cells. Dry eye syndrome was induced in male albino rabbits and further subdivided into untreated, Restasis-treated, EPCS, and S100-treated groups. Tear formation in the dry-eye-induced rabbits was evaluated using the Schirmer tear test. All formulations were also evaluated by ocular irritation tests using the Draize eye and winking methods with the determination of CsA concentration in rabbit tears. After the treatment, the Schirmer tear test value significantly improved in EPCS-treated (P=0.005) and S100-treated (P=0.018) groups compared to the Restasis-treated group. The AUC₀₋₂₄ h for rabbit's tear film after the administration of SCF-S100 was 32.75±9.21 μg·h/mg which was significantly higher than that of 24.59±8.69 μg·h/mg reported with Restasis. Liposomal CsA formulations used in this study showed lower irritation in rabbit eyes compared with Restasis. These results demonstrate that the novel SCF-mediated liposomal CsA promises a significant improvement in overcoming the challenges associated with the treatment of dry eyes.

  5. Evaluation of the toxicity of graphene oxide exposure to the eye.

    PubMed

    Wu, Wei; Yan, Liang; Wu, Qian; Li, Yijian; Li, Qiyou; Chen, Siyu; Yang, Yuli; Gu, Zhanjun; Xu, Haiwei; Yin, Zheng Qin

    2016-11-01

    Graphene and its derivatives are the new carbon nanomaterials with the prospect for great applications in electronics, energy storage, biosensors and medicine. However, little is known about the toxicity of graphene or its derivatives in the case of occasional or repeated ocular exposure. We performed in vitro and in vivo studies to evaluate the toxicity of graphene oxide (GO) exposure to the eye. Primary human corneal epithelium cells (hCorECs) and human conjunctiva epithelium cells (hConECs) were exposed to GO (12.5-100 μg/mL). Acute GO exposure (2 h) did not induce cytotoxicity to hCorECs. However, short-term GO exposure (24 h) exerted significant cytotoxicity to hCorECs and hConECs with increased intracellular reactive oxygen species (ROS). Glutathione (GSH) reduced the GO-induced cytotoxicity. We further performed acute eye irritation tests in albino rabbits according to the Organization for Economic Cooperation and Development (OECD) guidelines, and the rabbits did not exhibit corneal opacity, conjunctival redness, abnormality of the iris, or chemosis at any time point after the instillation of 100 μg/mL of GO. However, 5-day repeated GO exposure (50 and 100 μg/mL) caused reversible mild corneal opacity, conjunctival redness and corneal epithelium damage to Sprague-Dawley rats, which was also alleviated by GSH. Therefore, our study suggests that GO-induced time- and dose-dependent cytotoxicity to hCorECs and hConECs via oxidative stress. Occasional GO exposure did not cause acute eye irritation; short-term repeated GO exposure generally resulted in reversible damage to the eye via oxidative stress, which may be alleviated by the antioxidant GSH.

  6. Cyclodextrins in eye drop formulations: enhanced topical delivery of corticosteroids to the eye.

    PubMed

    Loftsson, Thorsteinn; Stefánsson, Einar

    2002-04-01

    Cyclodextrins are cylindrical oligosaccharides with a lipophilic central cavity and hydrophilic outer surface. They can form water-soluble complexes with lipophilic drugs, which 'hide' in the cavity. Cyclodextrins can be used to form aqueous eye drop solutions with lipophilic drugs, such as steroids and some carbonic anhydrase inhibitors. The cyclodextrins increase the water solubility of the drug, enhance drug absorption into the eye, improve aqueous stability and reduce local irritation. Cyclodextrins are useful excipients in eye drop formulations of various drugs, including steroids of any kind, carbonic anhydrase inhibitors, pilocarpine, cyclosporins, etc. Their use in ophthalmology has already begun and is likely to expand the selection of drugs available as eye drops. In this paper we review the properties of cyclodextrins and their application in eye drop formulations, of which their use in the formulation of dexamethasone eye drops is an example. Cyclodextrins have been used to formulate eye drops containing corticosteroids, such as dexamethasone, with levels of concentration and ocular absorption which, according to human and animal studies, are many times those seen with presently available formulations. Cyclodextrin-based dexamethasone eye drops are well tolerated in the eye and seem to provide a higher degree of bioavailability and clinical efficiency than the steroid eye drop formulations presently available. Such formulations offer the possibility of once per day application of corticosteroid eye drops after eye surgery, and more intensive topical steroid treatment in severe inflammation. While cyclodextrins have been known for more than a century, their use in ophthalmology is just starting. Cyclodextrins are useful excipients in eye drop formulations for a variety of lipophilic drugs. They will facilitate eye drop formulations for drugs that otherwise might not be available for topical use, while improving absorption and stability and decreasing local irritation.

  7. Evidence of Non-Linear Associations between Frustration-Related Prefrontal Cortex Activation and the Normal:Abnormal Spectrum of Irritability in Young Children.

    PubMed

    Grabell, Adam S; Li, Yanwei; Barker, Jeff W; Wakschlag, Lauren S; Huppert, Theodore J; Perlman, Susan B

    2018-01-01

    Burgeoning interest in early childhood irritability has recently turned toward neuroimaging techniques to better understand normal versus abnormal irritability using dimensional methods. Current accounts largely assume a linear relationship between poor frustration management, an expression of irritability, and its underlying neural circuitry. However, the relationship between these constructs may not be linear (i.e., operate differently at varying points across the irritability spectrum), with implications for how early atypical irritability is identified and treated. Our goal was to examine how the association between frustration-related lateral prefrontal cortex (LPFC) activation and irritability differs across the dimensional spectrum of irritability by testing for non-linear associations. Children (N = 92; ages 3-7) ranging from virtually no irritability to the upper end of the clinical range completed a frustration induction task while we recorded LPFC hemoglobin levels using fNIRS. Children self-rated their emotions during the task and parents rated their child's level of irritability. Whereas a linear model showed no relationship between frustration-related LPFC activation and irritability, a quadratic model revealed frustration-related LPFC activation increased as parent-reported irritability scores increased within the normative range of irritability but decreased with increasing irritability in the severe range, with an apex at the 91st percentile. Complementarily, we found children's self-ratings of emotion during frustration related to concurrent LPFC activation as an inverted U function, such that children who reported mild distress had greater activation than peers reporting no or high distress. Results suggest children with relatively higher irritability who are unimpaired may possess well-developed LPFC support, a mechanism that drops out in the severe end of the irritability dimension. Findings suggest novel avenues for understanding the heterogeneity of early irritability and its clinical sequelae.

  8. Dry eye disease caused by viral infection: review.

    PubMed

    Alves, Monica; Angerami, Rodrigo Nogueira; Rocha, Eduardo Melani

    2013-01-01

    Dry eye disease and ocular surface disorders may be caused or worsened by viral agents. There are several known and suspected virus associated to ocular surface diseases. The possible pathogenic mechanisms for virus-related dry eye disease are presented herein. This review serves to reinforce the importance of ophthalmologists as one of the healthcare professional able to diagnose a potentially large number of infected patients with high prevalent viral agents.

  9. Formulation Development, Optimization, and In vitro - In vivo Characterization of Natamycin Loaded PEGylated Nano-lipid Carriers for Ocular Applications.

    PubMed

    Patil, Akash; Lakhani, Prit; Taskar, Pranjal; Wu, Kai-Wei; Sweeney, Corinne; Avula, Bharathi; Wang, Yan-Hong; Khan, Ikhlas A; Majumdar, Soumyajit

    2018-04-23

    Current study aimed at formulating and optimizing natamycin (NT) loaded PEGylated NLCs (NT-PEG-NLCs) using Box-Behnken Design and investigating their potential in ocular applications. Response surface methodology (RSM) computations and plots for optimization were performed using Design Expert ® software, to obtain optimum values for response variables based on the criteria of desirability. Optimized NT-PEG-NLCs had predicted values for the dependent variables not significantly different from the experimental values. NT-PEG-NLCs were characterized for their physicochemical parameters; NT's rate of permeation and flux across rabbit cornea was evaluated, in vitro; ocular tissue distribution was assessed in rabbits, in vivo. NT-PEG-NLCs were found to have optimum particle size (< 300 nm) narrow PDI, high NT entrapment and NT content. In vitro transcorneal permeability and flux of NT from NT-PEG-NLCs was significantly higher than Natacyn ® . NT-PEG-NLC (0.3%) showed improved delivery of NT across the intact cornea and provided concentrations statistically similar to the marketed suspension (5%) in inner ocular tissues, in vivo, indicating that it could be a potential alternative to the conventional suspension during the course of fungal keratitis therapy. Copyright © 2018. Published by Elsevier Inc.

  10. [Mason's lacing cord. Potential danger of severe open ocular injuries].

    PubMed

    Tost, F; Großjohann, R; Schikorr, W; Tesch, R; Ekkernkamp, A; Lange, J; Langner, S; Bockholdt, B; Frank, M

    2014-02-01

    Introduction of new working equipment or the modification of established working routines could induce new trauma mechanisms. In all of theses cases ophthalmologists are not only responsible for ocular treatment they also have to act as assessors. This might include legal aspects, e.g. to validate the circumstances of an accident. We present a new trauma mechanism caused by a mason's lacing cord which was fixed with nails. In addition to two case studies we collected experimental data (maximum tension and maximum elongation of various mason's lacing cords) about the triggering event using standard test conditions. A tensile force of 96.2 N was needed to achieve maximum elongation of mason's lacing cords. With a cord length of 5 m, an elongation of 0.09 m was enough to cause penetrating injuries (for 10 m cord length the critical elongation was 0.13 m). Under these conditions a nail could be accelerated to a velocity of 18 m/s. This may lead to open eyeball injuries with severe visual loss. Nails fixed to elastic mason's lacing cords are potential risk factors for occupational ocular injuries and severe loss of vision. Caution labels should be attached to the work equipment and proper eye protection should be used to prevent severe occupational ocular injuries.

  11. Mold and Health

    EPA Pesticide Factsheets

    Molds have the potential to cause health problems. Molds produce allergens (substances that can cause allergic reactions) and irritants. Inhaling or touching mold or mold spores may cause allergic reactions in sensitive individuals.

  12. Dry Eye Syndrome in Menopause and Perimenopausal Age Group.

    PubMed

    Peck, Travis; Olsakovsky, Leslie; Aggarwal, Shruti

    2017-01-01

    Dry eye disease (DED) is a multifactorial ocular surface disease that causes symptoms of ocular pain, discomfort, and decreased visual acuity. It significantly affects quality of life of patients. It is more prevalent in the females and is being specifically in the menopausal and postmenopausal age group. This is believed to be due to the changes in balance of sex hormones. Sex hormones - estrogens and androgens - influence production of all components of the tear film including aqueous layer, lipid, and mucin. Various mechanisms such as decrease in hormonal levels, shift in feedback mechanisms, and changes in receptor receptivity interplay to alter the ocular surface homeostasis and subsequently result in DED. Several studies have suggested potential role of hormone replacement therapy in menopause-associated dry eye symptoms. The purpose of this review is to help the non ophthalmic physicians about DED encountered commonly in menopausal age group. It is important for primary care physicians to understand DED due to its high prevalence, often debilitating symptoms and the potentially preventable and treatable nature of the condition.

  13. Ocular Distribution and Pharmacokinetics of Lifitegrast in Pigmented Rabbits and Mass Balance in Beagle Dogs.

    PubMed

    Chung, Jou-Ku; Spencer, Elizabeth; Hunt, Matthew; McCauley, Thomas; Welty, Devin

    Lifitegrast is approved in the United States for the treatment of dry eye disease (DED). We assessed lifitegrast's ocular distribution/pharmacokinetic profile in rabbits, and 14 C-lifitegrast mass balance/excretion in dogs. Female pigmented rabbits received a single topical ocular dose of lifitegrast (Formulation No. 1, n = 25; No. 2, n = 25) per eye twice daily (target, 1.75 mg/eye/dose). Blood/ocular tissues were collected on day 5. Beagle dogs received single intravenous (n = 10; target, 3 mg, 262 μCi/animal) and ocular (n = 8, target, 3 mg, 30 μCi/eye) doses of 14 C-lifitegrast (∼8 weeks between doses). Blood, excreta, and cage rinse/wipes were collected. Concentrations were measured by mass spectrometry/liquid scintillation counting. Pharmacokinetic analyses (noncompartmental) included maximum concentration (C max ), time to C max (t max ), and area under the concentration-time curve from 0 to 8 h (AUC 0-8 ). In rabbits, lifitegrast C max and AUC 0-8 were similar between formulations. C max was highest in ocular anterior segment tissues: 5,190-14,200 ng/g [conjunctiva (palpebral/bulbar), cornea, anterior sclera]. Posterior segment tissues had lower concentrations (0-826 ng/g). AUC 0-8 followed a similar trend. Plasma concentrations were low (C max <18 ng/mL). Tissue/plasma t max was ∼0.25-1 h. In dogs, after intravenous/ocular doses, 14 C-lifitegrast was eliminated primarily through feces. Excreted radioactivity was mainly unchanged lifitegrast. High exposure of lifitegrast in rabbit ocular anterior segment tissues and low exposure in posterior segment tissues/plasma suggests that lifitegrast reaches target tissues for DED treatment, with low potential for off-target systemic/ocular effects. Excretion of unchanged 14 C-lifitegrast suggests minimal drug metabolism in vivo. This is consistent with lifitegrast clinical trial efficacy/safety data.

  14. E-cigarettes and smoking cessation. Similar efficacy to other nicotine delivery devices, but many uncertainties.

    PubMed

    2015-11-01

    E-cigarettes, marketed as an alternative to conventional cigarettes, are designed to transform a solution of variable composition, with or without nicotine, into an aerosol that the user inhales. How effective are e-cigarettes as an aid to smoking cessation, and what are their known adverse effects? To answer these questions, we conducted a review of the literature using the standard Prescrire methodology. A randomised trial involving 657 individuals who wanted to stop smoking compared e-cigarettes (with or without nicotine) with nicotine patches. There was no difference between the groups after 6 months, with an overall quit rate of about 5%. A double-blind randomised trial including 300 smokers compared the impact of e-cigarettes with or without nicotine on tobacco consumption. After 3 months, 14% of those using e-cigarettes with nicotine had quit completely, compared to 4% of those using e-cigarettes without nicotine. Adverse events reported in these trials were mild and transient, and mainly included dry mouth, irritation of the mouth and throat, dizziness, and nausea. When the solution ("e-liquid") contains nicotine, the main adverse effects are those of nicotine. Bronchial disorders, neuropsychiatric disorders and ocular irritation have been reported with inhaled propylene glycol. The effects of propylene glycol and glycerol, when heated and inhaled over long periods, are not known. The addictive effect is difficult to determine. Long-term use of e-cigarettes has been observed in about one-third of people who stopped smoking. Toxic or carcinogenic substances have been found in some e-cigarette aerosols, but at lower concentrations than in tobacco smoke. The diversity in the composition of e-liquids and the lack of proper controls make it difficult to assess the associated dangers. In early 2015, e-cigarettes containing nicotine appear to have efficacy similar to that of other nicotine delivery systems as an aid to smoking cessation. Apart from the effects of nicotine, there are few known adverse effects. However, there are many uncertainties as to the composition of the different e-liquids and the long-term effects of the substances when they are heated and inhaled. There is no reason to discourage smokers from substituting the proven, serious harms of tobacco smoke with the potential and poorly defined harms associated with e-cigarettes.

  15. Cationic Thiolated Poly(aspartamide) Polymer as a Potential Excipient for Artificial Tear Formulations.

    PubMed

    Budai-Szűcs, Mária; Horvát, Gabriella; Szilágyi, Barnabás Áron; Gyarmati, Benjámin; Szilágyi, András; Berkó, Szilvia; Szabó-Révész, Piroska; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Soós, Judit; Facskó, Andrea; Csányi, Erzsébet

    2016-01-01

    Dry eye disease is a relatively common ocular problem, which causes eye discomfort and visual disorders leading to a decrease in the quality of life. The aim of this study was to find a possible excipient for eye drop formulations, which is able to stabilize the tear film. A cationic thiolated polyaspartamide polymer, poly[(N-mercaptoethylaspartamide)-co-(N-(N',N'-dimethylaminoethyl)aspartamide)] (ThioPASP-DME), was used as a potential vehicle. Besides satisfying the basic requirements, the chemical structure of ThioPASP-DME is similar to those of ocular mucins as it is a protein-like polymer bearing a considerable number of thiol groups. The solution of the polymer is therefore able to mimic the physiological properties of the mucins and it can interact with the mucus layer via disulphide bond formation. The resultant mucoadhesion provides a prolonged residence time and ensures protective effect for the corneal/conjunctival epithelium. ThioPASP-DME also has an antioxidant effect due to the presence of the thiol groups. The applicability of ThioPASP-DME as a potential excipient in eye drops was determined by means of ocular compatibility tests and through examinations of the interactions with the mucosal surface. The results indicate that ThioPASP-DME can serve as a potential eye drop excipient for the therapy of dry eye disease.

  16. Protecting Children's Health During and After Natural Disasters

    EPA Pesticide Factsheets

    Learn about child-specific susceptibility to potential hazards associated with floods, extreme heat, and volcanic ash. These include mold, carbon monoxide, contaminated water, dehydration, heat stroke, and respiratory irritation.

  17. Allergens in the Lab.

    ERIC Educational Resources Information Center

    Fisher, Thomas M.

    1987-01-01

    Points out the health and legal implications related to laboratory substances that could cause allergic reactions. Presents a list of potential cosmetic allergens and irritants. Includes precautionary measures dealing with allergy situations. (ML)

  18. Mucins in contact lens wear and dry eye conditions.

    PubMed

    Ramamoorthy, Padmapriya; Nichols, Jason J

    2008-08-01

    Ocular mucins are thought to play integral roles in ocular surface lubrication, anchoring of the aqueous, stabilizing the lipid components of the tear film, eliminating foreign bodies and pathogens, and with potential involvement in cell cycle mediation and apoptotic activity of ocular surface epithelia. Ocular mucins are of secreted and membrane-associated types. Secreted mucins may be of large gel-forming type or small soluble mucins (e.g., MUC5AC and MUC7). Membrane-associated mucins such as MUCs 1 and 4 are a major component of the glycocalyx. They are thought to render structural support to the microplicae and mediate epithelial cell cycle and apoptotic activity. The alterations in ocular mucins with contact lens wear are unclear. Recent work shows mucin expression may be up-regulated during the early years of contact lens wear, and with long-term lens wear, mucin expression may return to normal levels or sub-normal levels, although this is not well understood. Further, the polar nature of mucins may be associated with their affinity for contact lens surfaces making them a component of contact lens deposition. This has potential implications in the wettability and tolerability of contact lenses, and may be impacted by surface coatings, polymer characteristics, or care solutions. Conjunctival mucin gene expression and secretion may be deficient in several ocular surface disorders associated with dry eye. Deficiency and alterations in glycosylation characteristics of MUC5AC and MUC2 have been reported in both Sjögren and non-Sjögren dry eye types. Decreased binding of the membrane-associated mucin MUC16 to the conjunctival epithelium has been reported in Sjögren dry eye while MUC1 alterations have been reported in Sjögren and non-Sjögren dry eye states. In view of the mucin involvement in dry eye conditions, stimulation of mucus secretion pathways may hold promise in the pharmaceutical treatment of dry eye.

  19. Antioxidant activity and irritation property of venoms from Apis species.

    PubMed

    Somwongin, Suvimol; Chantawannakul, Panuwan; Chaiyana, Wantida

    2018-04-01

    Pharmacological effects of bee venom has been reported, however, it has been restricted to the bee venom collected from European honey bee (Apis mellifera). The aim of the present study was to compare the antioxidant activities and irritation properties of venoms collected from four different Apis species in Thailand, which includes Apis cerena (Asian cavity nesting honeybee), Apis florea (dwarf honeybee), Apis dorsata (giant honeybee), and A. mellifera. Melittin content of each bee venom extracts was investigated by using high-performance liquid chromatography. Ferric reducing antioxidant power, 2, 2'-azinobis (3-ethylbenzothiazoline-6-sulfonic acid), and 1, 1-diphenyl-2-picrylhydrazyl assay were used to determine the antioxidant activity, whereas, hen's egg test chorioallantoic membrane assay was used to determine the irritation property of each bee venom extracts. Melittin was the major constituent in all bee venom extracts. The melittin content in A. dorsata, A. mellifera, A. florea, and A. cerena were 95.8 ± 3.2%, 76.5 ± 1.9%, 66.3 ± 8.6%, and 56.8 ± 1.8%, respectively. Bee venom extract from A. dorsata possessed the highest antioxidant activity with the inhibition of 41.1 ± 2.2% against DPPH, Trolox equivalent antioxidant capacity of 10.21 ± 0.74 mM Trolox/mg and equivalent concentration (EC 1 ) of 0.35 ± 0.02 mM FeSO 4 /mg. Bee venom extract from A. mellifera exhibited the highest irritation, followed by A. cerena, A. dorsata, and A. florea, respectively. Melittin was the compound responsible for the irritation property of bee venom extracts since it could induce severe irritation (irritation score was 13.7 ± 0.5, at the concentration of 2 mg/ml). The extract from A. dorsata which possessed the highest antioxidant activity showed no irritation up to the concentration of 0.1 mg/ml. Therefore, bee venom extract from A. dorsata at the concentration not more than 0.1 mg/ml would be suggested for using as cosmetic ingredients since it possessed the highest antioxidant activity with no irritation. This study is the first report to compare the bee venom extracts from different Apis species and display their potential application of bee venom extracts in cosmetic products. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Ocular manifestations of dengue fever in an East Indian epidemic.

    PubMed

    Kapoor, Harpreet K; Bhai, Saloni; John, Mary; Xavier, Jai

    2006-12-01

    The incidence and geographic distribution of dengue has increased dramatically in recent years. Previously, ocular findings in dengue fever were considered rare. We report a spectrum of ocular manifestations of this potentially fatal disease and its association with laboratory parameters. 134 patients hospitalized with a diagnosis of dengue fever during an epidemic were included. Systemic and ophthalmic examinations were completed on all patients. The mean age was 31.3 years and 63.4% were males. All patients presented with fever. Six (4.5%) patients had retrobulbar pain and none of the patients presented with any visual complaints. Ocular findings were present in 54 (40.3%) patients. Subconjunctival haemorrhage was the commonest eye finding seen in 50 patients, of whom 84% had characteristic petechial type of haemorrhages. Fundus findings present in 10 (7.5%) patients included dilatation and tortuosity of vessels, superficial retinal haemorrhages, cotton-wool spots, and hard exudates; the macula, however, was spared in all patients. Only 6 of the patients with posterior segment involvement returned for follow-up examination and it was found that retinal changes had resolved without any specific treatment within 2 to 8 weeks time. Of all laboratory parameters evaluated, marked thrombocytopenia (platelet count <50,000/microL) emerged to be significantly associated with ocular haemorrhage. Multiple subconjunctival haemorrhages, especially petechial type, are a common manifestation of dengue infection. Dengue fever patients with marked thrombocytopenia are predisposed to spontaneous ocular haemorrhages.

Top