Sample records for ocular surface toxicity

  1. Therapeutic Effects of Sodium Hyaluronate on Ocular Surface Damage Induced by Benzalkonium Chloride Preserved Anti-glaucoma Medications

    PubMed Central

    Liu, Xing; Yu, Fen-Fen; Zhong, Yi-Min; Guo, Xin-Xing; Mao, Zhen

    2015-01-01

    Background: Long-term use of benzalkonium chloride (BAC)-preserved drugs is often associated with ocular surface toxicity. Ocular surface symptoms had a substantial impact on the glaucoma patients’ quality of life and compliance. This study aimed to investigate the effects of sodium hyaluronate (SH) on ocular surface toxicity induced by BAC-preserved anti-glaucoma medications treatment. Methods: Fifty-eight patients (101 eyes), who received topical BAC-preserved anti-glaucoma medications treatment and met the severe dry eye criteria, were included in the analysis. All patients were maintained the original topical anti-glaucoma treatment. In the SH-treated group (56 eyes), unpreserved 0.3% SH eye drops were administered with 3 times daily for 90 days. In the control group (55 eyes), phosphate-buffered saline were administered with 3 times daily for 90 days. Ocular Surface Disease Index (OSDI) questionnaire, break-up time (BUT) test, corneal fluorescein staining, corneal and conjunctival rose Bengal staining, Schirmer test, and conjunctiva impression cytology were performed sequentially on days 0 and 91. Results: Compared with the control group, SH-treated group showed decrease in OSDI scores (Kruskal-Wallis test: H = 38.668, P < 0.001), fluorescein and rose Bengal scores (Wilcoxon signed-ranks test: z = −3.843, P < 0.001, and z = −3.508, P < 0.001, respectively), increase in tear film BUT (t-test: t = −10.994, P < 0.001) and aqueous tear production (t-test: t = −10.328, P < 0.001) on day 91. The goblet cell density was increased (t-test: t = −9.981, P < 0.001), and the morphology of the conjunctival epithelium were also improved after SH treatment. Conclusions: SH significantly improved both symptoms and signs of ocular surface damage in patients with BAC-preserved anti-glaucoma medications treatment. SH could be proposed as a new attempt to reduce ocular surface toxicity, and alleviate symptoms of ocular surface damage in BAC-preserved anti-glaucoma medications treatment. PMID:26365960

  2. Comparison of efficacy and ocular surface toxicity of topical preservative-free methylprednisolone and preserved prednisolone in the treatment of acute anterior uveitis.

    PubMed

    Hedayatfar, Alireza; Hashemi, Hassan; Asgari, Soheila; Chee, Soon-Phaik

    2014-04-01

    The aim of this study was to compare the antiinflammatory effect and ocular surface toxicity of topical nonpreserved methylprednisolone sodium succinate 1% and preserved prednisolone acetate suspension 1% for the management of acute anterior uveitis (AAU). In this prospective, randomized, investigator-masked, comparative clinical trial, patients with mild-to-moderate noninfectious AAU were assigned randomly to receive either hourly nonpreserved methylprednisolone 1% (group A) or preserved prednisolone 1% (group B) eye drops followed by a 2-week tapering regimen. Anterior chamber cells and flare were clinically evaluated for the objective comparison of the antiinflammatory effect. The main outcome measure was the percentage of patients with a resolution of inflammation (anterior chamber cells <1+) on day 14. Ocular surface toxicity was assessed by means of the corneal fluorescein staining score, tear breakup time, Schirmer I test, and questionnaire-based grading of ocular discomfort parameters. Seventy-two eyes of 68 patients were studied, of which 38 eyes were enrolled in group A and 34 eyes were enrolled in group B. On day 14, 76.3% of the patients in group A had resolution of inflammation compared with 70.6% of the patients in group B, proving noninferiority (χ = 0.303, P = 0.582). The mean anterior chamber cell grade reduction for patients in group A was similar to that in group B (2.52 vs. 2.86, respectively; P = 0.92). Group A patients showed significantly lower corneal fluorescein staining scores (P < 0.001) and reported milder subjective ocular discomfort (0.55 vs. 1.43, P = 0.01) as compared with group B. Both preparations demonstrated equal antiinflammatory effects for the treatment of AAU. Nonpreserved methylprednisolone eye drops exhibited a significantly lower ocular surface toxicity profile and milder subjective discomfort when compared with that exhibited by preserved prednisolone.

  3. PRESERVATIVES FROM THE EYE DROPS AND THE OCULAR SURFACE

    PubMed Central

    Coroi, Mihaela Cristina; Bungau, Simona; Tit, Mirela

    2015-01-01

    The use of preservatives in eye drops (eyewashes) has known glory at the beginning, but the side effects that they have on the ocular surface have led to a decrease of their popularity. Lachrymal film dysfunction, ocular hyperemia, dotted keratitis or toxic keratopathy were reported and analyzed in terms of pathophysiological mechanism of the role played by preservatives in ophthalmic drops (eyewashes). This article reviews the most common preservatives and the existing alternatives for the maintenance of the eye sterile drops. PMID:27373107

  4. [Challenge and treatment strategy for ocular surface damage in patients with long term use of antiglaucoma drugs].

    PubMed

    He, Xiang-Ge

    2011-02-01

    Long term use of topical anti-glaucoma drugs has been shown to induce chronic conjunctivitis, superficial punctate keratitis (SPK) and dry eye symptom. Under these conditions, a loss of goblet cells in conjunctiva, epithelial squamous metaplasia and apoptosis were morphologically revealed. Benzalkonium Chloride (BKC), a most frequently used preservative in eye drops, has been found to be an important factor causing ocular surface damage. Furthermore, a big challenge for ophthalmologists is that toxic damage of medication to ocular surface tissues is mild, poor specificity, and delayed manifestation in patients, especially when coexisting with other ocular surface diseases. Impairment of ocular surface tissues greatly impacts the life quality of patients and subsequently influences compliance with glaucoma therapy. This paper emphasizes to take measures to prevent ocular surface tissue damage resulted from chronic use of topical anti-glaucoma drugs and further discusses the treatment strategy. Effective and long-lasting action drugs should always be selected for glaucomatous patients in order to decrease the frequency of topical instillation or at a more expensive medication, a fixed combination formula can be considered for glaucoma therapy. An early surgery or laser treatment is also proposed for the patients who require an IOP reduction with an existing ocular surface impairment. Future investigation and development of new medications with long-term efficacy and appropriate BKC are suggested and preservative-free or drugs with new preservative materials recommended.

  5. Toxicities of topical ophthalmic anesthetics.

    PubMed

    McGee, Hall T; Fraunfelder, F W

    2007-11-01

    Topical ocular anesthesia has been part of ophthalmology for more than a century. The most commonly used drugs today are proparacaine, tetracaine, benoxinate (oxybuprocaine) cocaine and lidocaine. Although generally well tolerated, all these can be toxic, particularly when abused. The most common toxicities are to the ocular surface, but abuse can cause deep corneal infiltrates, ulceration and even perforation. Fortunately, systemic side effects are rare. Cocaine is unique for its higher incidence of systemic side effects and high abuse potential, both of which impede its clinical use. When used appropriately, all these drugs are remarkably safe. They are generally not prescribed for home use, as prolonged abuse of these drugs can be expected to result in serious complications.

  6. Reduction of quaternary ammonium-induced ocular surface toxicity by emulsions: an in vivo study in rabbits

    PubMed Central

    Liang, H.; Brignole-Baudouin, F.; Rabinovich-Guilatt, L.; Mao, Z.; Riancho, L.; Faure, M.O.; Warnet, J.M.; Lambert, G.

    2008-01-01

    Purpose To evaluate and compare the toxicological profiles of two quaternary ammonium compounds (QAC), benzalkonium chloride (BAK), and cetalkonium chloride (CKC), in standard solution or cationic emulsion formulations in rabbit eyes using newly developed in vivo and ex vivo experimental approaches. Methods Seventy eyes of 35 adult male New Zealand albino rabbits were used in this study. They were randomly divided into five groups: 50 µl of phosphate-buffered saline (PBS), PBS containing 0.02% BAK or 0.002% CKC (BAK Sol and CKC Sol, respectively), and emulsion containing 0.02% BAK or 0.002% CKC (BAK Em and CKC Em, respectively) were applied to rabbit eyes 15 times at 5-min intervals. The ocular surface changes induced by these eye drops were investigated using slit-lamp examination, flow cytometry (FCM), impression cytology (IC) on conjunctiva, and corneal in vivo confocal microscopy (IVCM). Standard immunohistology in cryosections was also examined for cluster of differentiation (CD) 45+ infiltrating and terminal deoxynucleotidyl transferase-mediated dUTP-nick end labeling (TUNEL)+ apoptotic cells. Results Clinical observations and IVCM showed that the highest toxicity was induced by BAK Sol, characterized by damaged corneal epithelium and a high level of inflammatory infiltration. BAK Em and CKC Sol presented moderate effects, and CKC Em showed the lowest toxicity with results similar to those of PBS. Conjunctival imprints analyzed by FCM showed a higher expression of RLA-DR and TNFR1 markers in BAK Sol-instilled eyes than in all other groups, especially at 4 h. Immunohistology was correlated with in vivo and ex vivo findings and confirmed this toxicity profile. A high level of infiltration of CD45+ inflammatory cells and TUNEL+ apoptotic cells was observed in limbus and conjunctiva, especially in QAC solution-receiving eyes compared to QAC emulsion-instilled eyes. Conclusions The acute administration of 15 instillations at 5 min intervals was a rapid and efficient model to assess quaternary ammonium toxicity profiles. This model showed the highest toxicity, induced by the BAK solution, and the lowest level of toxicity, induced by the CKC emulsion. These in vivo and ex vivo experimental approaches demonstrated that ocular surface toxicity was reduced by using an emulsion instead of a traditional solution and that a CKC emulsion was safe for future ocular administration. PMID:18347566

  7. Reduction of quaternary ammonium-induced ocular surface toxicity by emulsions: an in vivo study in rabbits.

    PubMed

    Liang, H; Brignole-Baudouin, F; Rabinovich-Guilatt, L; Mao, Z; Riancho, L; Faure, M O; Warnet, J M; Lambert, G; Baudouin, C

    2008-01-31

    To evaluate and compare the toxicological profiles of two quaternary ammonium compounds (QAC), benzalkonium chloride (BAK), and cetalkonium chloride (CKC), in standard solution or cationic emulsion formulations in rabbit eyes using newly developed in vivo and ex vivo experimental approaches. Seventy eyes of 35 adult male New Zealand albino rabbits were used in this study. They were randomly divided into five groups: 50 microl of phosphate-buffered saline (PBS), PBS containing 0.02% BAK or 0.002% CKC (BAK Sol and CKC Sol, respectively), and emulsion containing 0.02% BAK or 0.002% CKC (BAK Em and CKC Em, respectively) were applied to rabbit eyes 15 times at 5-min intervals. The ocular surface changes induced by these eye drops were investigated using slit-lamp examination, flow cytometry (FCM), impression cytology (IC) on conjunctiva, and corneal in vivo confocal microscopy (IVCM). Standard immunohistology in cryosections was also examined for cluster of differentiation (CD) 45+ infiltrating and terminal deoxynucleotidyl transferase-mediated dUTP-nick end labeling (TUNEL)+ apoptotic cells. Clinical observations and IVCM showed that the highest toxicity was induced by BAK Sol, characterized by damaged corneal epithelium and a high level of inflammatory infiltration. BAK Em and CKC Sol presented moderate effects, and CKC Em showed the lowest toxicity with results similar to those of PBS. Conjunctival imprints analyzed by FCM showed a higher expression of RLA-DR and TNFR1 markers in BAK Sol-instilled eyes than in all other groups, especially at 4 h. Immunohistology was correlated with in vivo and ex vivo findings and confirmed this toxicity profile. A high level of infiltration of CD45+ inflammatory cells and TUNEL+ apoptotic cells was observed in limbus and conjunctiva, especially in QAC solution-receiving eyes compared to QAC emulsion-instilled eyes. The acute administration of 15 instillations at 5 min intervals was a rapid and efficient model to assess quaternary ammonium toxicity profiles. This model showed the highest toxicity, induced by the BAK solution, and the lowest level of toxicity, induced by the CKC emulsion. These in vivo and ex vivo experimental approaches demonstrated that ocular surface toxicity was reduced by using an emulsion instead of a traditional solution and that a CKC emulsion was safe for future ocular administration.

  8. Comparative Toxicity of Preservatives on Immortalized Corneal and Conjunctival Epithelial Cells

    PubMed Central

    Ahdoot, Michael; Marcus, Edward; Asbell, Penny A.

    2009-01-01

    Abstract Purpose Nearly all eye drops contain preservatives to decrease contamination. Nonpreservatives such as disodium-ethylene diamine tetra-acetate (EDTA) and phosphate-buffered saline are also regularly added as buffering agents. These components can add to the toxicity of eye drops and cause ocular surface disease. To evaluate the potential toxicity of these common components and their comparative effects on the ocular surface, a tissue culture model utilizing immortalized corneal and conjunctival epithelial cells was utilized. Methods Immortalized human conjunctival and corneal epithelial cells were grown. At confluency, medium was replaced with 100 μL of varying concentrations of preservatives: benzalkonium chloride (BAK), methyl paraben (MP), sodium perborate (SP), chlorobutanol (Cbl), and stabilized thimerosal (Thi); varying concentrations of buffer: EDTA; media (viable control); and formalin (dead control). After 1 h, solutions were replaced with 150 μL of MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazonium bromide). After 4 h, solutions decanted, 100 μL of acid isopropanol added, and the optical density determined at 572 nm to evaluate cell viability. Results Conjunctival and corneal cell toxicity was seen with all preservatives. Depending upon concentration, BAK exhibited from 56% to 89% toxicity. In comparison, Cbl exhibited from 50% to 86%, MP from 30% to 76%, SP from 23% to 59%, and Thi from 70% to 95%. EDTA with minimal toxicity (from 6% to 59%) was indistinguishable from SP. Conclusions Generally, the order of decreasing toxicity at the most commonly used concentrations: Thi (0.0025%) > BAK (0.025%) > Cbl (0.25%) > MP (0.01%) > SP (0.0025%) ≈ EDTA (0.01%). Even at low concentration, these agents will cause some degree of ocular tissue damage. PMID:19284328

  9. Ocular Adverse Events Associated with Antibody–Drug Conjugates in Human Clinical Trials

    PubMed Central

    Miller, Paul E.; Mannis, Mark J.

    2015-01-01

    Abstract This article reviews ocular adverse events (AEs) reported in association with administration of antibody–drug conjugates (ADCs) in human clinical trials. References reporting ocular toxicity or AEs associated with ADCs were collected using online publication searches. Articles, abstracts, or citations were included if they cited ocular toxicities or vision-impairing AEs with a confirmed or suspected association with ADC administration. Twenty-two references were found citing ocular or vision-impairing AEs in association with ADC administration. All references reported use of ADCs in human clinical trials for treatment of various malignancies. The molecular target and cytotoxic agent varied depending on the ADC used. Ocular AEs affected a diversity of ocular tissues. The most commonly reported AEs involved the ocular surface and included blurred vision, dry eye, and corneal abnormalities (including microcystic corneal disease). Most ocular AEs were not severe (≤ grade 2) or dose limiting. Clinical outcomes were not consistently reported, but when specified, most AEs improved or resolved with cessation of treatment or with ameliorative therapy. A diverse range of ocular AEs are reported in association with administration of ADCs for the treatment of cancer. The toxicologic mechanism(s) and pathogenesis of such events are not well understood, but most are mild in severity and reversible. Drug development and medical professionals should be aware of the clinical features of these events to facilitate early recognition and intervention in the assessment of preclinical development programs and in human clinical trials. PMID:26539624

  10. Ocular toxicities associated with targeted anticancer agents: an analysis of clinical data with management suggestions

    PubMed Central

    Fu, Chen; Gombos, Dan S; Lee, Jared; George, Goldy C; Hess, Kenneth; Whyte, Andrew; Hong, David S

    2017-01-01

    Ocular toxicities are among the most common adverse events resulting from targeted anticancer agents and are becoming increasingly relevant in the management of patients on these agents. The purpose of this study is to provide a framework for management of these challenging toxicities based on objective data from FDA labels and from analysis of the literature. All oncologic drugs approved by the FDA up to March 14, 2015, were screened for inclusion. A total of 16 drugs (12 small-molecule drugs and 4 monoclonal antibodies) were analyzed for ocular toxicity profiles based on evidence of ocular toxicity. Trials cited by FDA labels were retrieved, and a combination search in Medline, Google Scholar, the Cochrane database, and the NIH Clinical Trials Database was conducted. The majority of ocular toxicities reported were low severity, and the most common were conjunctivitis and “visual disturbances.” However, severe events including incidents of blindness, retinal vascular occlusion, and corneal ulceration occurred. The frequency and severity at which ocular toxicities occur merits a more multidisciplinary approach to managing patients with agents that are known to cause ocular issues. We suggest a standardized methodology for referral and surveillance of patients who are potentially at risk of severe ocular toxicity. PMID:28938590

  11. Ocular changes with oxaliplatin.

    PubMed

    O'Dea, Denise; Handy, Catherine M; Wexler, Ann

    2006-04-01

    Ocular toxicity, although uncommon, can occur with many chemotherapeutic agents. Platinum compounds have been documented to produce a variety of ocular side effects, and reports have been made of ocular toxicity with oxaliplatin. This article reports on four patients who experienced ocular symptoms while receiving oxaliplatin. The symptoms included tunnel vision and visual loss with postural changes. One patient had objective findings that included papilledema. All of the changes were reversible. Oxaliplatin will continue to be used widely, so clinicians treating patients with it must be alert for unusual toxicities such as those described in this article.

  12. Emerging toxicities in the treatment of non-small cell lung cancer: ocular disorders.

    PubMed

    Agustoni, Francesco; Platania, Marco; Vitali, Milena; Zilembo, Nicoletta; Haspinger, Eva; Sinno, Valentina; Gallucci, Rosaria; de Braud, Filippo; Garassino, Marina Chiara

    2014-02-01

    The treatment of advanced disease (stage IIIb and IV) of non-small cell lung cancer (NSCLC) is based on systemic treatment with platinum-based chemotherapy or biological compounds depending on the disease molecular profile. In the last few years, intensive investigational efforts in anticancer therapy have led to the registration of new active chemotherapeutic agents, combination regimens, and biological drugs, expanding choices for customizing individual treatment. However, the introduction of new drugs in the clinical setting has led to several new toxicities, creating some difficulties in daily management. Among these, ocular toxicity is generally overlooked as more common toxicities such as myelosuppression, stomatitis, diarrhea, vomiting, "hand-foot syndrome", and neurological alterations attract greater attention. Ophthalmic complications from cytotoxic chemotherapeutics are rare, transient, and of mild/moderate intensity but irreversible acute disorders are possible. The best way to prevent potential irreversible visual complications is an awareness of the potential for ocular toxicity because dose reductions or early drug cessation can prevent serious ocular complications in the majority of cases. However, given the novelty of many therapeutic agents and the complexity of ocular pathology, oncologists may be unfamiliar with these adverse effects of anticancer therapy. Although toxicities from chemotherapy are generally intense but short lasting, toxicities related to targeted drugs are often milder but longer lasting and can persist throughout treatment. Here we review the principal clinical presentations of ocular toxicity arising from chemotherapy [1-3], target therapies [4], and newly developed drugs and provide some recommendations for monitoring and management of ocular toxicity. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. How Ocular Surface Disease Impacts the Glaucoma Treatment Outcome

    PubMed Central

    Kaštelan, Snježana; Tomić, Martina; Metež Soldo, Kata; Salopek-Rabatić, Jasminka

    2013-01-01

    The treatment goals for glaucoma are lowering the intraocular pressure and preservation of vision. Topical hypotensive drops are the standard form of therapy which is often associated with some symptoms of toxicity, ocular inflammation, allergy, or ocular surface disease (OSD). OSD is a common comorbidity in glaucoma patients, and its prevalence with glaucoma increases with age. Use of topical treatment could additionally increase symptoms of OSD mostly due to preservatives added to multidose medication bottles used to reduce the risk of microbial contamination. This toxicity has been particularly associated with BAK, the most commonly used preservative which damages conjunctival and corneal epithelial cells and significantly aggravates OSD symptoms. OSD adversely affects patients' quality of life causing discomfort and problems with vision which in turn may result in noncompliance, lack of adherence, and eventually visual impairment. In the management of glaucoma patients OSD symptoms should not be overlooked. If they are present, topical glaucoma treatment should be adapted by decreasing the amount of drops instilled daily, using BAK-free or preservative-free medication and lubricants if necessary. Awareness of the presence and importance of OSD will in turn improve patients' adherence and compliance and thus ultimately the preservation of long-term vision. PMID:24224176

  14. In vitro methods of assessing ocular biocompatibility using THP-1-derived macrophages.

    PubMed

    McCanna, David Joseph; Barthod-Malat, Aurore V; Gorbet, Maud B

    2015-01-01

    Macrophages play an important role in the elimination of infections, the removal of debris and in tissue repair after infection and trauma. In vitro models that assess ocular biomaterials for toxicity typically focus on the effects of these materials on epithelial or fibroblast cells. This investigation evaluated known ocular toxins deposited on model materials for their effects on the viability and activation of macrophages. THP-1-derived macrophages were cultured onto silicone films (used as a base biomaterial) deposited with chemical toxins (benzalkonium chloride (BAK), zinc diethyldithiocarbamate (ZDEC) and lipopolysaccharide (LPS)). Utilizing three fluorescent dyes calcein, ethidium homodimer-1 (EthD-1) and annexin V, the viability of macrophages attached to the biomaterial was determined using confocal microscopy. Propidium iodide (PI) staining and alamarBlue® (resazurin) reduction were used to assess cell death and metabolic activity. CD14, CD16, CD33, CD45, and CD54 expression of adherent macrophages, were also evaluated to detect LPS activation of macrophages using flow cytometry. The sensitivity of this test battery was demonstrated as significant toxicity from treated surfaces with ZDEC (0.001-0.01%), and BAK (0.001%-0.1%) was detected. Also, macrophage activation could be detected by measuring CD54 expression after exposure to adsorbed LPS. These in vitro methods will be helpful in determining the toxicity potential of new ocular biomaterials.

  15. Expression of prostaglandin E receptor subtype EP4 in conjunctival epithelium of patients with ocular surface disorders: case-control study.

    PubMed

    Ueta, Mayumi; Sotozono, Chie; Yamada, Keiko; Yokoi, Norihiko; Inatomi, Tsutomu; Kinoshita, Shigeru

    2012-01-01

    To confirm the downregulation of PTGER4 mRNA in the conjunctiva of Stevens-Johnson syndrome/toxic epidermal necrolysis (SJS/TEN) and ocular cicatricial pemphigoid (OCP) patients and to examine the expression of its EP4 protein in the conjunctival epithelium of patients with various ocular surface disorders. Case-control study. We performed quantitative reverse transcription-PCR (RT-PCR) analysis of PTGER4 mRNA in conjunctival tissue sections from patients with SJS/TEN and OCP to confirm the downregulation of PTGER4 mRNA expression. We also analysed EP4 immunohistologically in other ocular surface disorders. Conjunctival tissues were obtained from patients undergoing surgical reconstruction of the ocular surface due to chemical eye burns, subacute SJS/TEN or chronic SJS/TEN, chronic OCP, severe graft versus host disease (GVHD) and from patients with Mooren's ulcers treated by resection of the inflammatory conjunctiva. The expression of PTGER4 mRNA and EP4 protein assessed by quantitative RT-PCR assay and immunohistological methods. PTGER4 mRNA was significantly lower in conjunctival tissues from SJS and OCP patients than in the control conjunctivochalasis samples. EP4 protein was detected in conjunctival epithelium from patients with chemical eye burn and in control conjunctival epithelium from patients with conjunctivochalasis. Its expression varied in conjunctival epithelium from patients with Mooren's ulcer. We did not detect EP4 immunoreactivity in conjunctival epithelium from patients with subacute SJS/TEN, severe GVHD, chronic SJS/TEN or OCP. The strong downregulation of EP4 expression in conjunctival epithelium from patients with OCP or SJS/TEN may be attributable to ocular surface inflammation.

  16. Expression of prostaglandin E receptor subtype EP4 in conjunctival epithelium of patients with ocular surface disorders: case-control study

    PubMed Central

    Ueta, Mayumi; Sotozono, Chie; Yamada, Keiko; Yokoi, Norihiko; Inatomi, Tsutomu; Kinoshita, Shigeru

    2012-01-01

    Objectives To confirm the downregulation of PTGER4 mRNA in the conjunctiva of Stevens-Johnson syndrome/toxic epidermal necrolysis (SJS/TEN) and ocular cicatricial pemphigoid (OCP) patients and to examine the expression of its EP4 protein in the conjunctival epithelium of patients with various ocular surface disorders. Design Case-control study. Setting and participants We performed quantitative reverse transcription-PCR (RT-PCR) analysis of PTGER4 mRNA in conjunctival tissue sections from patients with SJS/TEN and OCP to confirm the downregulation of PTGER4 mRNA expression. We also analysed EP4 immunohistologically in other ocular surface disorders. Conjunctival tissues were obtained from patients undergoing surgical reconstruction of the ocular surface due to chemical eye burns, subacute SJS/TEN or chronic SJS/TEN, chronic OCP, severe graft versus host disease (GVHD) and from patients with Mooren's ulcers treated by resection of the inflammatory conjunctiva. Primary and secondary outcome measures The expression of PTGER4 mRNA and EP4 protein assessed by quantitative RT-PCR assay and immunohistological methods. Results PTGER4 mRNA was significantly lower in conjunctival tissues from SJS and OCP patients than in the control conjunctivochalasis samples. EP4 protein was detected in conjunctival epithelium from patients with chemical eye burn and in control conjunctival epithelium from patients with conjunctivochalasis. Its expression varied in conjunctival epithelium from patients with Mooren's ulcer. We did not detect EP4 immunoreactivity in conjunctival epithelium from patients with subacute SJS/TEN, severe GVHD, chronic SJS/TEN or OCP. Conclusions The strong downregulation of EP4 expression in conjunctival epithelium from patients with OCP or SJS/TEN may be attributable to ocular surface inflammation. PMID:23065448

  17. Ocular surface involvements in ectrodactyly-ectodermal dysplasia-cleft syndrome.

    PubMed

    Kennedy, David P; Chandler, John W; McCulley, James P

    2015-06-01

    To present the ocular manifestation of 2 cases of ectrodactyly-ectodermal dysplasia-cleft syndrome, a multiple congenital anomaly syndrome caused by a single point mutation of the p63 gene that controls epidermal development and homeostasis and to present treatment options. Patient 1 presented with mild signs and symptoms of dry eye and limbal stem cell deficiency with retention of 20/30 vision. Patient 2 presented with severe signs and symptoms of limbal stem cell deficiency with diffuse corneal scarring and counting fingers vision. This second patient's course was complicated by allergic conjunctivitis and advanced steroid-induced glaucoma. The cause of visual loss in ectrodactyly-ectodermal dysplasia-cleft syndrome appears to be multifactorial and likely includes inflammation of the ocular surface, tear film abnormalities, eyelid abnormalities, and limbal stem cell deficiency. Treatment modalities including lubrication, contact lenses, and limbal stem cell transplantation are reviewed. The ophthalmic conditions seen in ectrodactyly-ectodermal dysplasia-cleft syndrome frequently lead to vision loss. Early correct diagnosis and appropriate therapy are paramount because p63 gene mutations have a critical role in maintaining the integrity of the ocular surface in the setting of limbal stem cell deficiency, especially if there are other ocular surface insults such as lid disease, meibomian gland dysfunction and toxicity from topical medications. Patients should be monitored at regular, frequent intervals; and particular attention should be taken to avoid adverse secondary effects of these conditions and medications. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Cyclodextrin Enhances Corneal Tolerability and Reduces Ocular Toxicity Caused by Diclofenac

    PubMed Central

    Abdelkader, Hamdy; Fathalla, Zeinab; Moharram, Hossam; Ali, Taha F. S.

    2018-01-01

    With advances in refractive surgery and demand for cataract removal and lens replacement, the ocular use of nonsteroidal anti-inflammatory drugs (NSAIDs) has increased. One of the most commonly used NSAIDs is diclofenac (Diclo). In this study, cyclodextrins (CDs), α-, β-, γ-, and HP-β-CDs, were investigated with in vitro irritation and in vivo ulceration models in rabbits to reduce Diclo toxicity. Diclo-, α-, β-, γ-, and HP-β-CD inclusion complexes were prepared and characterized and Diclo-CD complexes were evaluated for corneal permeation, red blood cell (RBCs) haemolysis, corneal opacity/permeability, and toxicity. Guest- (Diclo-) host (CD) solid inclusion complexes were formed only with β-, γ-, and HP-β-CDs. Amphipathic properties for Diclo were recorded and this surfactant-like functionality might contribute to the unwanted effects of Diclo on the surface of the eye. Contact angle and spreading coefficients were used to assess Diclo-CDs in solution. Reduction of ocular toxicity 3-fold to16-fold and comparable corneal permeability to free Diclo were recorded only with Diclo-γ-CD and Diclo-HP-β-CD complexes. These two complexes showed faster healing rates without scar formation compared with exposure to the Diclo solution and to untreated groups. This study also highlighted that Diclo-γ-CD and Diclo-HP-β-CD demonstrated fast healing without scar formation. PMID:29636847

  19. [Preservatives in ophthalmology].

    PubMed

    Messmer, E M

    2012-11-01

    Preservatives are a legal requirement for eye drops in multidose containers. Moreover, they are necessary for stabilization and intraocular penetration for a number of ophthalmic preparations. Most preservatives act in a relatively unspecific manner as detergents or by oxidative mechanisms and thereby cause side effects at the ocular surface. They may also affect the lens, trabecular meshwork and the retina. Benzalkonium chloride is the most commonly used preservative in ophthalmology and is more toxic than other or newer preservatives, such as polyquaternium-1 (Polyquad), sodium perborate, oxychloro-complex (Purite®) and SofZia. Preservative-free topical medication is highly recommended for patients with ocular surface disease, frequent eye drop administration, proven allergy to preservatives and contact lens wear.

  20. Hydrosilylated Porous Silicon Particles Function as an Intravitreal Drug Delivery System for Daunorubicin

    PubMed Central

    Hartmann, Kathrin I.; Nieto, Alejandra; Wu, Elizabeth C.; Freeman, William R.; Kim, Jae Suk; Chhablani, Jay; Sailor, Michael J.

    2013-01-01

    Abstract Purpose To evaluate in vivo ocular safety of an intravitreal hydrosilylated porous silicon (pSi) drug delivery system along with the payload of daunorubicin (DNR). Methods pSi microparticles were prepared from the electrochemical etching of highly doped, p-type Si wafers and an organic linker was attached to the Si-H terminated inner surface of the particles by thermal hydrosilylation of undecylenic acid. DNR was bound to the carboxy terminus of the linker as a drug-loading strategy. DNR release from hydrosilylated pSi particles was confirmed in the excised rabbit vitreous using liquid chromatography–electrospray ionization–multistage mass spectrometry. Both empty and DNR-loaded hydrosilylated pSi particles were injected into the rabbit vitreous and the degradation and safety were studied for 6 months. Results The mean pSi particle size was 30×46×15 μm with an average pore size of 15 nm. Drug loading was determined as 22 μg per 1 mg of pSi particles. An ex vivo drug release study showed that intact DNR was detected in the rabbit vitreous. An in vivo ocular toxicity study did not reveal clinical or pathological evidence of any toxicity during a 6-month observation. Hydrosilylated pSi particles, either empty or loaded with DNR, demonstrated a slow elimination kinetics from the rabbit vitreous without ocular toxicity. Conclusions Hydrosilylated pSi particles can host a large quantity of DNR by a covalent loading strategy and DNR can be slowly released into the vitreous without ocular toxicity, which would appear if an equivalent quantity of free drug was injected. PMID:23448595

  1. Oxaliplatin-Related Ocular Toxicity

    PubMed Central

    Mesquida, Marina; Sanchez-Dalmau, Bernardo; Ortiz-Perez, Santiago; Pelegrín, Laura; Molina-Fernandez, Juan José; Figueras-Roca, Marc; Casaroli-Marano, Ricardo; Adán, Alfredo

    2010-01-01

    We report the case of a 52-year-old woman with advanced colorectal cancer who was treated with oxaliplatin on a FOLFOX schedule. After 3 cycles of chemotherapy, she started to complain of visual loss, altered color vision and neurological symptoms. Due to the suspicion of ocular and neurological toxicity, antineoplastic treatment was stopped. Her visual field showed a concentric bilateral scotoma and the electrooculogram test revealed severe impairment of the retinal pigment epithelium. Visual acuity, color vision and visual field recovered completely 8 months later, although electrooculogram remained abnormal. Ocular toxicity has been reported as an infrequent adverse event of oxaliplatin. Findings in this case indicate toxicity of this chemotherapeutic agent on the retinal pigment epithelium, which has not been reported before. This damage could be permanent, and it thus differs from previously described oxaliplatin-induced ocular toxicities, which are usually transient and reversible. With increasing use of oxaliplatin as first-line treatment in advanced colorectal cancer, we have to be aware of this possible toxicity. PMID:21151636

  2. Conjunctival and corneal reactions in rabbits following short- and repeated exposure to preservative-free tafluprost, commercially available latanoprost and 0.02% benzalkonium chloride

    PubMed Central

    Liang, H; Baudouin, C; Pauly, A; Brignole-Baudouin, F

    2008-01-01

    Aim: To compare the conjunctival and corneal reactions of commercially available solution of latanoprost (Xalatan) and preservative-free (PF) tafluprost in rabbits. Methods: The rabbits received 50 μl of phosphate-buffered saline (PBS), PF-tafluprost 0.0015%, latanoprost 0.005% or benzalkonium chloride (BAK) 0.02%; all solutions were applied at 5 min intervals for a total of 15 times. The ocular surface toxicity was investigated using slit-lamp biomicroscopy examination, flow cytometry (FCM) and on imprints for CD45 and tumour necrosis factor-receptor 1 (TNFR1) conjunctival impression cytology (CIC) and corneal in vivo confocal microscopy (IVCM). Standard immunohistology also assessed inflammatory/apoptotic cells. Results: Clinical observation and IVCM images showed the highest ocular surface toxicity with latanoprost and BAK, while PF-tafluprost and PBS eyes presented almost normal corneoconjunctival aspects. FCM showed a higher expression of CD45+ and TNFR1+ in latanoprost- or BAK-instilled groups, compared with PF-tafluprost and PBS groups. Latanoprost induced fewer positive cells for inflammatory marker expressions in CIC specimens compared with BAK-alone, both of which were higher than with PF-tafluprost or PBS. Immunohistology showed the same tendency of toxic ranking. Conclusion: The authors confirm that rabbit corneoconjunctival surfaces presented a better tolerance when treated with PF-tafluprost compared with commercially available latanoprost or BAK solution. PMID:18723745

  3. Polymeric micelles for ocular drug delivery: From structural frameworks to recent preclinical studies.

    PubMed

    Mandal, Abhirup; Bisht, Rohit; Rupenthal, Ilva D; Mitra, Ashim K

    2017-02-28

    Effective intraocular drug delivery poses a major challenge due to the presence of various elimination mechanisms and physiological barriers that result in low ocular bioavailability after topical application. Over the past decades, polymeric micelles have emerged as one of the most promising drug delivery platforms for the management of ocular diseases affecting the anterior (dry eye syndrome) and posterior (age-related macular degeneration, diabetic retinopathy and glaucoma) segments of the eye. Promising preclinical efficacy results from both in-vitro and in-vivo animal studies have led to their steady progression through clinical trials. The mucoadhesive nature of these polymeric micelles results in enhanced contact with the ocular surface while their small size allows better tissue penetration. Most importantly, being highly water soluble, these polymeric micelles generate clear aqueous solutions which allows easy application in the form of eye drops without any vision interference. Enhanced stability, larger cargo capacity, non-toxicity, ease of surface modification and controlled drug release are additional advantages with polymeric micelles. Finally, simple and cost effective fabrication techniques render their industrial acceptance relatively high. This review summarizes structural frameworks, methods of preparation, physicochemical properties, patented inventions and recent advances of these micelles as effective carriers for ocular drug delivery highlighting their performance in preclinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Ocular Toxicity Profile of ST-162 and ST-168 as Novel Bifunctional MEK/PI3K Inhibitors.

    PubMed

    Smith, Andrew; Pawar, Mercy; Van Dort, Marcian E; Galbán, Stefanie; Welton, Amanda R; Thurber, Greg M; Ross, Brian D; Besirli, Cagri G

    2018-04-30

    ST-162 and ST-168 are small-molecule bifunctional inhibitors of MEK and PI3K signaling pathways that are being developed as novel antitumor agents. Previous small-molecule and biologic MEK inhibitors demonstrated ocular toxicity events that were dose limiting in clinical studies. We evaluated in vitro and in vivo ocular toxicity profiles of ST-162 and ST-168. Photoreceptor cell line 661W and adult retinal pigment epithelium cell line ARPE-19 were treated with increasing concentrations of bifunctional inhibitors. Western blots, cell viability, and caspase activity assays were performed to evaluate MEK and PI3K inhibition and dose-dependent in vitro toxicity, and compared with monotherapy. In vivo toxicity profile was assessed by intravitreal injection of ST-162 and ST-168 in Dutch-Belted rabbits, followed by ocular examination and histological analysis of enucleated eyes. Retinal cell lines treated with ST-162 or ST-168 exhibited dose-dependent inhibition of MEK and PI3K signaling. Compared with inhibition by monotherapies and their combinations, bifunctional inhibitors demonstrated reduced cell death and caspase activity. In vivo, both bifunctional inhibitors exhibited a more favorable toxicity profile when compared with MEK inhibitor PD0325901. Novel MEK and PI3K bifunctional inhibitors ST-162 and ST-168 demonstrate favorable in vitro and in vivo ocular toxicity profiles, supporting their further development as potential therapeutic agents targeting multiple aggressive tumors.

  5. Ocular toxicity of fludarabine

    PubMed Central

    Ding, Xiaoyan; Herzlich, Alexandra A; Bishop, Rachel; Tuo, Jingsheng; Chan, Chi-Chao

    2008-01-01

    The purine analogs, fludarabine and cladribine represent an important class of chemotherapy agents used to treat a broad spectrum of lymphoid malignancies. Their toxicity profiles include dose-limiting myelosuppression, immunosuppression, opportunistic infection and severe neurotoxicity. This review summarizes the neurotoxicity of high- and standard-dose fludarabine, focusing on the clinical and pathological manifestations in the eye. The mechanisms of ocular toxicity are probably multifactorial. With increasing clinical use, an awareness of the neurological and ocular vulnerability, particularly to fludarabine, is important owing to the potential for life- and sight-threatening consequences. PMID:18461151

  6. Nanoparticles in the ocular drug delivery

    PubMed Central

    Zhou, Hong-Yan; Hao, Ji-Long; Wang, Shuang; Zheng, Yu; Zhang, Wen-Song

    2013-01-01

    Ocular drug transport barriers pose a challenge for drug delivery comprising the ocular surface epithelium, the tear film and internal barriers of the blood-aqueous and blood-retina barriers. Ocular drug delivery efficiency depends on the barriers and the clearance from the choroidal, conjunctival vessels and lymphatic. Traditional drug administration reduces the clinical efficacy especially for poor water soluble molecules and for the posterior segment of the eye. Nanoparticles (NPs) have been designed to overcome the barriers, increase the drug penetration at the target site and prolong the drug levels by few internals of drug administrations in lower doses without any toxicity compared to the conventional eye drops. With the aid of high specificity and multifunctionality, DNA NPs can be resulted in higher transfection efficiency for gene therapy. NPs could target at cornea, retina and choroid by surficial applications and intravitreal injection. This review is concerned with recent findings and applications of NPs drug delivery systems for the treatment of different eye diseases. PMID:23826539

  7. Toxic epitheliopathy from a single application of preservative free oxybuprocaine (0.4%) in a patient with Sjogren's syndrome.

    PubMed

    Ansari, Humaira; Weinberg, Laurence; Spencer, Narelle

    2013-09-13

    Topical ocular anaesthetic agents are frequently used for ophthalmic diagnosis and surgery. While corneal complications following long-term use or misuse of local anaesthetic solutions have been described, toxic epitheliopathy after a single application of six drops of preservative free oxybuprocaine is rare. In order to increase the awareness of this ocular complication, we report such a case in a patient with Sjogren's syndrome who presented for elective cataract surgery. We outline the mechanisms proposed to explain the ocular toxic effects of oxybuprocaine and discuss the management principles in preventing this complication in the context of Sjogren's syndrome.

  8. Toxic epitheliopathy from a single application of preservative free oxybuprocaine (0.4%) in a patient with Sjogren's syndrome

    PubMed Central

    Ansari, Humaira; Weinberg, Laurence; Spencer, Narelle

    2013-01-01

    Topical ocular anaesthetic agents are frequently used for ophthalmic diagnosis and surgery. While corneal complications following long-term use or misuse of local anaesthetic solutions have been described, toxic epitheliopathy after a single application of six drops of preservative free oxybuprocaine is rare. In order to increase the awareness of this ocular complication, we report such a case in a patient with Sjogren's syndrome who presented for elective cataract surgery. We outline the mechanisms proposed to explain the ocular toxic effects of oxybuprocaine and discuss the management principles in preventing this complication in the context of Sjogren's syndrome. PMID:24038291

  9. Transport and interaction of cosmetic product material within the ocular surface: beauty and the beastly symptoms of toxic tears.

    PubMed

    Malik, Adeela; Claoué, Charles

    2012-12-01

    Eye cosmetics such as mascara, eye shadow and eyeliner are used extensively to highlight the eyes, and are normally applied external to the ocular surface. Adverse reactions of cosmetics within the ocular surface include mild discomfort, eyelid dermatitis, pre-corneal tear film instability, and keratitis. These are attributed mainly to the preservative (benzalkonium chloride (BAC)) constituent of cosmetic product material (CPM). Transport of CPM from an external environment to any location on the ocular surface, essentially precedes the adverse interactions occurring at the location, and the control of these transport modes is therefore of clinical relevance. The inter-transport of CPM across the TF occurs due to both diffusion and drift processes. Diffusion of neutral species is driven by concentration gradients, and the drift of cationic BAC is influenced by the inherent electric field; determined by the distribution of the various ions secreted into the aqueous layer, and the negative glycocalyx charge at the mucin layer. In the presence of mucin deficiency, the corneal epithelium is exposed to invasion by both incident BAC and lipophilic species. The transport of cationic BAC across the TF may be controlled by regulating the secretion of various electrolytes at the lacrimal gland. This is of clinical significance in reducing corneal epithelial adverse effects. However, the risks of adverse effects at the corneal surface due to invasion by the lipophilic species remain. Patients with mucin deficiency, and especially those on eye ointment/drops medication, should be discouraged from using cosmetics in a way likely to contaminate the TF. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  10. Toxicity of cosmetic preservatives on human ocular surface and adnexal cells.

    PubMed

    Chen, Xiaomin; Sullivan, David A; Sullivan, Amy Gallant; Kam, Wendy R; Liu, Yang

    2018-05-01

    Cosmetic products, such as mascara, eye shadow, eyeliner and eye makeup remover are used extensively to highlight the eyes or clean the eyelids, and typically contain preservatives to prevent microbial growth. These preservatives include benzalkonium chloride (BAK) and formaldehyde (FA)-releasing preservatives. We hypothesize that these preservatives, at concentrations (BAK = 1 mg/ml; FA = 0.74 mg/ml) approved for consumer use, are toxic to human ocular surface and adnexal cells. Accordingly, we tested the influence of BAK and FA on the morphology, survival, and proliferation and signaling ability of immortalized human meibomian gland (iHMGECs), corneal (iHCECs) and conjunctival (iHConjECs) epithelial cells. iHMGECs, iHCECs and iHConjECs were cultured with different concentrations of BAK (5 μg/ml to 0.005 μg/ml) or FA (1 mg/ml to 1 μg/ml) under basal, proliferating or differentiating conditions up to 7 days. We used low BAK levels, because we found that 0.5 mg/ml and 50 μg/ml BAK killed iHMGECs within 1 day after a 15 min exposure. Experimental procedures included analyses of cell appearance, cell number, and neutral lipid content (LipidTox), lysosome accumulation (LysoTracker) and AKT signaling in all 3 cell types. Our results demonstrate that BAK and FA cause dose-dependent changes in the morphology, survival, proliferation and AKT signaling of iHMGECs, iHCECs and iHConjECs. Many of the concentrations tested induced cell atrophy, poor adherence, decreased proliferation and death, after 5 days of exposure. Cellular signaling, as indicated by AKT phosphorylation after 15 (FA) or 30 (BAK) minutes of treatment, was also reduced in a dose-dependent fashion in all 3 cell types, irrespective of whether cells had been cultured under proliferating or differentiating conditions. Our results support our hypothesis and demonstrate that the cosmetic preservatives, BAK and FA, exert many toxic effects on cells of the ocular surface and adnexa. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Noninvasive ocular drug delivery: potential transcorneal and other alternative delivery routes for therapeutic molecules in glaucoma.

    PubMed

    Foldvari, Marianna

    2014-01-01

    Drug delivery to the eye is made difficult by multiple barriers (such as the tear film, cornea, and vitreous) between the surface of the eye and the treatment site. These barriers are difficult to surmount for the purposes of drug delivery without causing toxicity. Using nanotechnology tools to control, manipulate, and study delivery systems, new approaches to delivering drugs, genes, and antigens that are effective and safe can be developed. Topical administration to the ocular surface would be the safest method for delivery, as it is noninvasive and painless compared with other delivery methods. However, there is only limited success using topical delivery methods, especially for gene therapy. Current thinking on treatments of the future enabled by nanodelivery systems and the identification of target specificity parameters that require deeper understanding to develop successful topical delivery systems for glaucoma is highlighted.

  12. Optimization and physicochemical characterization of a triamcinolone acetonide-loaded NLC for ocular antiangiogenic applications.

    PubMed

    Araújo, J; Gonzalez-Mira, E; Egea, M A; Garcia, M L; Souto, E B

    2010-06-30

    The purpose of this study was to develop a novel nanostructured lipid carrier (NLC) for the intravitreal-targeting delivery of triamcinolone acetonide (TA) by direct ocular instillation. A five-level central composite rotable design was used to study the influence of four different variables on the physicochemical characteristics of NLCs. The analysis of variance (ANOVA) statistical test was used to assess the optimization of NLC production parameters. The systems were produced by high pressure homogenization using Precirol ATO5 and squalene as solid and liquid lipids respectively, and Lutrol F68 as surfactant. Homogenization at 600 bar for 3 cycles of the optimized formulation resulted in the production of small NLC (mean diameter < 200 nm) with a homogeneous particle size distribution (polydispersity index (PI) approximately 0.1), of negatively charged surface (approximately |45| mV) and high entrapment efficiency (approximately 95%). Surface morphology was assessed by SEM which revealed fairly spherical shape. DSC, WAXS and FT-IR analyses confirmed that TA was mostly entrapped into the NLC, characterized by an amorphous matrix. In vivo Draize test showed no signs of ocular toxicity. 2010 Elsevier B.V. All rights reserved.

  13. Oxidized Porous Silicon Particles Covalently Grafted with Daunorubicin as a Sustained Intraocular Drug Delivery System

    PubMed Central

    Chhablani, Jay; Nieto, Alejandra; Hou, Huiyuan; Wu, Elizabeth C.; Freeman, William R.; Sailor, Michael J.; Cheng, Lingyun

    2013-01-01

    Purpose. To test the feasibility of covalent loading of daunorubicin into oxidized porous silicon (OPS) and to evaluate the ocular properties of sustained delivery of daunorubicin in this system. Methods. Porous silicon was heat oxidized and chemically functionalized so that the functional linker on the surface was covalently bonded with daunorubicin. The drug loading rate was determined by thermogravimetric analysis. Release of daunorubicin was confirmed in PBS and excised rabbit vitreous by mass spectrometry. Daunorubicin-loaded OPS particles (3 mg) were intravitreally injected into six rabbits, and ocular properties were evaluated through ophthalmic examinations and histology during a 3-month study. The same OPS was loaded with daunorubicin using physical adsorption and was evaluated similarly as a control for the covalent loading. Results. In the case of covalent loading, 67 ± 10 μg daunorubicin was loaded into each milligram of the particles while 27 ± 10 μg/mg particles were loaded by physical adsorption. Rapid release of daunorubicin was observed in both PBS and excised vitreous (∼75% and ∼18%) from the physical adsorption loading, while less than 1% was released from the covalently loaded particles. Following intravitreal injection, the covalently loaded particles demonstrated a sustained degradation of OPS with drug release for 3 months without evidence of toxicity; physical adsorption loading revealed a complete release within 2 weeks and localized retinal toxicity due to high daunorubicin concentration. Conclusions. OPS with covalently loaded daunorubicin demonstrated sustained intravitreal drug release without ocular toxicity, which may be useful to inhibit unwanted intraocular proliferation. PMID:23322571

  14. Riot Control Agents

    DTIC Science & Technology

    2009-01-01

    However, a local anesthetic applied to the eye will help with eye pain and allow for further evaluation of the eye by slit lamp. Contact lenses...RCAs. Eye findings from RCA toxicity can range in severity from conjunctival erythema to ocular necrosis . Lacrimation, conjunctival erythema/edema...and ocular necrosis (Grant, 1986). Figure 12.12 illustrates and summarizes the common toxic ophthalmological signs and symptoms associated with

  15. Conjunctiva-Associated Lymphoid Tissue (CALT) Reactions to Antiglaucoma Prostaglandins with or without BAK-Preservative in Rabbit Acute Toxicity Study

    PubMed Central

    Liang, Hong; Baudouin, Christophe; Labbe, Antoine; Riancho, Luisa; Brignole-Baudouin, Françoise

    2012-01-01

    Conjunctiva-associated lymphoid tissue (CALT) is closely associated with ocular surface immunity. This study investigated the effects of antiglaucoma prostaglandin analogs with or without benzalkonium chloride (BAK) preservative on organized CALT using an acute toxic model. A total of 48 albino rabbits were used and seven groups of treatments were constituted. Solutions (50 µl) of PBS, 0.02%BAK, 0.02%BAK+latanoprost, 0.015%BAK+travoprost, 0.005%BAK+bimatoprost, BAK-freetravoprost preserved with the SofZia® system or BAK-freetafluprost were instilled 15 times at 5-min intervals in both eyes. CALT changes were analyzed using in vivo confocal microscopy (IVCM), immunohistology in cryosections for detecting MUC-5AC+ mucocytes and CD45+ hematopoietic cells. Antiglaucoma eye drops stimulated inflammatory cell infiltration in the CALT, and seemed to be primarily related to the concentration of their BAK content. The CALT reaction after instillation of BAK-containing eye drops was characterized by inflammatory cell infiltration in the dome and intrafollicular layers and by cell circulation inside the lymph vessels. CD45 was strongly expressed in the CALT after instillation of all BAK-containing solutions at 4 h and decreased at 24 h. The number of MUC-5AC+ mucocytes around the CALT structure decreased dramatically after instillation of BAK-containing solutions. This study showed for the first time the in vivo aspect of rabbit CALT after toxic stimuli, confirming the concentration-dependent toxic effects of BAK. IVCM-CALT analysis could be a pertinent tool in the future for understanding the immunotoxicologic challenges in the ocular surface and would provide useful criteria for evaluating newly developed eye drops. PMID:22442734

  16. Management of the ocular surface and tear film before, during, and after laser in situ keratomileusis.

    PubMed

    Albietz, Julie M; Lenton, Lee M

    2004-01-01

    To identify evidence-based, best practice strategies for managing the ocular surface and tear film before, during, and after laser in situ keratomileusis (LASIK). After a comprehensive review of relevant published literature, evidence-based recommendations for best practice management strategies are presented. Symptoms of ocular irritation and signs of dysfunction of the integrated lacrimal gland/ocular surface functional gland unit are common before and after LASIK. The status of the ocular surface and tear film before LASIK can impact surgical outcomes in terms of potential complications during and after surgery, refractive outcome, optical quality, patient satisfaction, and the severity and duration of dry eye after LASIK. Before LASIK, the health of the ocular surface should be optimized and patients selected appropriately. Dry eye before surgery and female gender are risk factors for developing chronic dry eye after LASIK. Management of the ocular surface during LASIK can minimize ocular surface damage and the risk of adverse outcomes. Long-term management of the tear film and ocular surface after LASIK can reduce the severity and duration of dry eye symptoms and signs. Strategies to manage the integrated ocular surface/lacrimal gland functional unit before, during, and after LASIK can optimize outcomes. As problems with the ocular surface and tear film are relatively common, attention should focus on the use and improvement of evidence-based management strategies.

  17. Development of novel encapsulated formulations using albumin-chitosan as a polymer matrix for ocular drug delivery

    NASA Astrophysics Data System (ADS)

    Addo, Richard Tettey

    Designing formulations for ophthalmic drug delivery is one of the most challenging endeavors facing the pharmaceutical scientist due to the unique anatomy, physiology, and biochemistry of the eye. Current treatment protocols for administration of drugs in eye diseases are primarily solution formulations, gels or ointments. However, these modes of delivery have several drawbacks such as short duration of exposure, need for repeated administrations and non-specific toxicity. We hypothesize that development of ocular drugs in microparticles will overcome the deficiencies of the current modalities of treatment. We based the hypothesis on the preliminary studies conducted with encapsulated tetracaine, an anesthetic used for surgical purposes and atropine, a medication used for several ophthalmic indications including mydriatic and cycloplegic effects. However, atropine is well absorbed into the systemic circulation and has been reported to exert severe systemic side effects after ocular administration (Hoefnagel D. 1961, Morton H. G. 1939 and Lang J. C. 1995) and may lead to serious side effects including death in extreme cases with pediatric use. Based on these observations, the focus of this dissertation is to formulate microparticulate drug carrier for treatment of various conditions of the eye. Purpose: To prepare, characterize, study the in vitro and in vivo interaction of albumin-chitosan microparticles (BSA-CSN MS), a novel particulate drug carrier for ocular drug delivery. Method: Microparticle formulations were prepared by method of spray drying. The percentage drug loading and efficiency were assessed using USP (I) dissolution apparatus. Using Malvern Zeta-Sizer, we determined size and surface charge of the fabrication. Surface morphology of the microparticles was examined using Scanning Electron Microscopy. Microparticles were characterized in terms of thermal properties using Differential Scanning Calorimetry. Human corneal epithelial cells (HCET-1) were exposed up to 120 minutes to different BSA-CSN MS concentrations. Using fluorometry, the influence of temperature and effect of metabolic inhibition were studied. The in vitro uptake and internalization studies were evaluated using confocal microscopy in HCET-1. In vivo studies were evaluated in rabbit's eye using blink response and pupil to cornea ratio for tetracaine and atropine studies respectively. Results: Our results showed particles size in the range of 3-5 microns with encapsulation efficiency of about 96 percent. Differential Scanning Calorimetry showed no drug-polymer interactions. BSA-CSN MS were internalized by the HCET-1 and was affected both by temperature and metabolic inhibitor, sodium azide. There were no signs of ocular surface toxicity or inflammation. The encapsulated drugs exhibited superior properties in vivo compared to the solution formulations currently in clinical use. Conclusion: We successfully developed microparticulate drug carriers for ocular delivery. BSA-CSN MS were internalized by the HCET-1 by temperature dependent active transport mechanism that did not compromise cell viability.

  18. The role of microbial flora on the ocular surface.

    PubMed

    Miller, Darlene; Iovieno, Alfonso

    2009-10-01

    Presence and interplay of microbial flora at the ocular surface reveal dynamic and evolving interactions with implications for both ocular surface health and disease. Data in this area are scarce or non-existent. The purpose of this review is to provide a snapshot of new and emerging developments in this area over the last 12 months. Recent findings signal potential roles for ocular surface microbial flora in both the preservation and extension of ocular surface health and in the initiation of new or escalation of common surface disorders. Contributions range from priming surface epithelial immune cells to regulating mucin composition and production. Other findings explore the emergent role of ocular microbial flora cross talk with pattern recognition receptors to protect and strengthen local and adaptive mucosal immunity while preserving vision. Deciphering the functional role of microbial communities at the ocular surface could bring new insights into and clarify the epidemiology and pathology of ocular surface dynamics in health and disease.

  19. Proof of Principle of Ocular sparing in dogs with sinonasal tumors treated with intensity-modulated radiation therapy

    PubMed Central

    Lawrence, Jessica A.; Forrest, Lisa J.; Turek, Michelle M.; Miller, Paul E.; Mackie, T. Rockwell; Jaradat, Hazim A.; Vail, David M.; Dubielzig, Richard R.; Chappell, Richard; Mehta, Minesh P.

    2010-01-01

    Intensity modulated radiation therapy (IMRT) allows optimization of radiation dose delivery to complex tumor volumes with rapid dose drop-off to surrounding normal tissues. A prospective study was performed to evaluate the concept of conformal avoidance using IMRT in canine sinonasal cancer. The potential of IMRT to improve clinical outcome with respect to acute and late ocular toxicity was evaluated. Thirty-one dogs with sinonasal cancer were treated definitively with IMRT using helical tomotherapy and/or dynamic multileaf collimator (DMLC) delivery. Ocular toxicity was evaluated prospectively and compared to a comparable group of historical controls treated with conventional two-dimensional radiotherapy (2D-RT) techniques. Treatment plans were devised for each dog using helical tomotherapy and DMLC that achieved the target dose to the planning treatment volume and limited critical normal tissues to the prescribed dose-volume constraints. Overall acute and late toxicities were limited and minor, detectable by an experienced observer. This was in contrast to the profound ocular morbidity observed in the historical control group treated with 2D-RT. Overall median survival for IMRT treated and 2D treated dogs was 420 days and 411 days, respectively. Compared with conventional techniques, IMRT reduced dose delivered to eyes and resulted in bilateral ocular sparing in the dogs reported herein. These data provide proof-of-principle that conformal avoidance radiotherapy can be delivered through high conformity IMRT, resulting in decreased normal tissue toxicity as compared to historical controls treated with 2D-RT. PMID:20973393

  20. Effects of environment pollution on the ocular surface.

    PubMed

    Jung, Se Ji; Mehta, Jodhbir S; Tong, Louis

    2018-04-01

    The twenty-first century is fraught with dangers like climate change and pollution, which impacts human health and mortality. As levels of pollution increase, respiratory illnesses and cardiovascular ailments become more prevalent. Less understood are the eye-related complaints, which are commonly associated with increasing pollution. Affected people may complain of irritation, redness, foreign body sensation, tearing, and blurring of vision. Sources of pollution are varied, ranging from gases (such as ozone and NO 2 ) and particulate matter produced from traffic, to some other hazards associated with indoor environments. Mechanisms causing ocular surface disease involve toxicity, oxidative stress, and inflammation. Homeostatic mechanisms of the ocular surface may adapt to certain chronic changes in the environment, so affected people may not always be symptomatic. However there are many challenges associated with assessing effects of air pollution on eyes, as pollution is large scale and difficult to control. Persons with chronic allergic or atopic tendencies may have a pre-existing state of heightened mucosal immune response, hence they may have less tolerance for further environmental antigenic stimulation. It is beneficial to identify vulnerable people whose quality of life will be significantly impaired by environmental changes and provide counter measures in the form of protection or treatment. Better technologies in monitoring of pollutants and assessment of the eye will facilitate progress in this field. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Conjugation of cell-penetrating peptides with poly(lactic-co-glycolic acid)-polyethylene glycol nanoparticles improves ocular drug delivery

    PubMed Central

    Vasconcelos, Aimee; Vega, Estefania; Pérez, Yolanda; Gómara, María J; García, María Luisa; Haro, Isabel

    2015-01-01

    In this work, a peptide for ocular delivery (POD) and human immunodeficiency virus transactivator were conjugated with biodegradable poly(lactic-co-glycolic acid) (PGLA)–polyethylene glycol (PEG)-nanoparticles (NPs) in an attempt to improve ocular drug bioavailability. The NPs were prepared by the solvent displacement method following two different pathways. One involved preparation of PLGA NPs followed by PEG and peptide conjugation (PLGA-NPs-PEG-peptide); the other involved self-assembly of PLGA-PEG and the PLGA-PEG-peptide copolymer followed by NP formulation. The conjugation of the PEG and the peptide was confirmed by a colorimetric test and proton nuclear magnetic resonance spectroscopy. Flurbiprofen was used as an example of an anti-inflammatory drug. The physicochemical properties of the resulting NPs (morphology, in vitro release, cell viability, and ocular tolerance) were studied. In vivo anti-inflammatory efficacy was assessed in rabbit eyes after topical instillation of sodium arachidonate. Of the formulations developed, the PLGA-PEG-POD NPs were the smaller particles and exhibited greater entrapment efficiency and more sustained release. The positive charge on the surface of these NPs, due to the conjugation with the positively charged peptide, facilitated penetration into the corneal epithelium, resulting in more effective prevention of ocular inflammation. The in vitro toxicity of the NPs developed was very low; no ocular irritation in vitro (hen’s egg test–chorioallantoic membrane assay) or in vivo (Draize test) was detected. Taken together, these data demonstrate that PLGA-PEG-POD NPs are promising vehicles for ocular drug delivery. PMID:25670897

  2. Dry Eye Management: Targeting the Ocular Surface Microenvironment.

    PubMed

    Zhang, Xiaobo; M, Vimalin Jeyalatha; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo; Li, Wei

    2017-06-29

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment.

  3. Dry Eye Management: Targeting the Ocular Surface Microenvironment

    PubMed Central

    Zhang, Xiaobo; Jeyalatha M, Vimalin; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo

    2017-01-01

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment. PMID:28661456

  4. The pathology of dry eye: the interaction between the ocular surface and lacrimal glands.

    PubMed

    Stern, M E; Beuerman, R W; Fox, R I; Gao, J; Mircheff, A K; Pflugfelder, S C

    1998-11-01

    Most dry-eye symptoms result from an abnormal, nonlubricative ocular surface that increases shear forces under the eyelids and diminishes the ability of the ocular surface to respond to environmental challenges. This ocular-surface dysfunction may result from immunocompromise due to systemic autoimmune disease or may occur locally from a decrease in systemic androgen support to the lacrimal gland as seen in aging, most frequently in the menopausal female. Components of the ocular surface (cornea, conjunctiva, accessory lacrimal glands, and meibomian glands), the main lacrimal gland, and interconnecting innervation act as a functional unit. When one portion is compromised, normal lacrimal support of the ocular surface is impaired. Resulting immune-based inflammation can lead to lacrimal gland and neural dysfunction. This progression yields the OS symptoms associated with dry eye. Restoration of lacrimal function involves resolution of lymphocytic activation and inflammation. This has been demonstrated in the MRL/lpr mouse using systemic androgens or cyclosporine and in the dry-eye dog using topical cyclosporine. The efficacy of cyclosporine may be due to its immunomodulatory and antiinflammatory (phosphatase inhibitory capability) functions on the ocular surface, resulting in a normalization of nerve traffic. Although the etiologies of dry eye are varied, common to all ocular-surface disease is an underlying cytokine/receptor-mediated inflammatory process. By treating this process, it may be possible to normalize the ocular surface/lacrimal neural reflex and facilitate ocular surface healing.

  5. Adjuvant treatment or primary topical monotherapy for ocular surface squamous neoplasia: a systematic review.

    PubMed

    Viani, Gustavo Arruda; Fendi, Ligia Issa de

    2017-01-01

    In this systematic review, we evaluated studies involving adjuvant and primary topical treatment for ocular surface squamous neoplasia (OSSN). The findings were: (i) adjuvant 5-fluorouracil (5-FU) reduces the risk of relapse after surgical excision with mild side effects [level Ib, grade of recommendation (GR) A]. (ii) Primary topical mitomycin (MMC) produces a high rate of complete response, low recurrence rate, and mild side effects (level Ib, GR A). (iii) Primary chemotherapy versus adjuvant chemotherapy produce similar rates of recurrence, with no significant difference (level IIb, GR B). (iv) Adjuvant 5-FU versus MMC showed no significant differences, with mild side effects in both groups and a better toxicity profile for MMC (level III, GR C). (v) Primary topical 5-FU versus MMC versus interferon (IFN) showed similar rates of tumor recurrence, mild side effects for all drugs, and more severe side effects in the 5-FU arm, followed successively by MMC and IFN (level III, GR C).

  6. Ocular surface injury from a microwave superheated egg resulting in a pseudopterygium.

    PubMed

    Gagnon, Michael R; Dickinson, Paul J

    2005-05-01

    To describe the first case of ocular surface injury resulting in a pseudopterygium from a microwave superheated egg. Case report. A 12-year-old girl sustained an ocular surface injury resulting in a pseudopterygium from a microwave superheated egg. Microwave superheated eggs can result in ocular injury. This case illustrates the potential ocular danger involved with microwave ovens.

  7. Ocular Toxicity Testing of Lunar Dust

    NASA Technical Reports Server (NTRS)

    Meyers, Valerie E.

    2010-01-01

    This slide presentation reviews the use of ocular testing to determine the toxicity of lunar dust. The OECD recommendations are reviewed. With these recommendations in mind the test methodology was to use EpiOcular, tissues derived from normal human epidermal keratinocytes, the cells of which have been differentiated on cell culture inserts to form a multi-layered structure, which closely parallels the corneal epithelium and to dose the tissue with 100 mg dust from various sources. The in-vitro study provides evidence that lunar dust is not severely corrosive or irritating, however, in vitro tests have limitations, and in vivo tests provides a more complete scenario, and information, it is recommended that in vivo tests be performed.

  8. The tear film and ocular mucins.

    PubMed

    Davidson, Harriet J; Kuonen, Vanessa J

    2004-01-01

    Abstract The trilaminar tear film, composed of the lipid, aqueous and mucin layers, has many functions including defending the ocular surface. The aqueous layer has several soluble antimicrobial factors that protect the ocular surface. Ocular mucins have recently been studied with regard to their role in the defense of the eye as well as in dry eye syndromes. To date, 15 mucin genes have been identified, and six of these mucin genes are localized to or secreted by ocular glands or epithelia. Understanding the production, secretion and function of ocular mucins will aid in the treatment of dry eye syndromes and ocular surface microbial infections.

  9. Significance of mucin on the ocular surface.

    PubMed

    Watanabe, Hitoshi

    2002-03-01

    To review the significance of mucin in the tear film and the ocular surface epithelium. Summary of the information on how mucin derived from the corneal and conjunctival epithelia and from goblet cells plays a role in the stability of the tear film over the ocular surface. The change in mucin expression derived from the ocular surface epithelium is also discussed with reference to ocular surface disease. The corneal and conjunctival epithelia produce transmembrane mucins such as MUC1, MUC2, and MUC4. In contrast, goblet cells produce the gel-forming secretory mucin, MUC5AC. The lacrimal gland produces MUC7. On the ocular surface, cooperation between transmembrane mucin and secretory mucin is necessary for the stability of the tear film. The expression of mucin from the ocular surface epithelium is coordinated from the time of eyelid opening and is altered in conditions such as squamous metaplasia and dry eye. This alteration may result in instability of the tear film. CONCLU SION: The induction of mucin from the ocular surface may facilitate the stability of the tear film, and increased knowledge may lead to the development of a new modality for the treatment of dry eye.

  10. The mucosal surfaces of both eyes are immunologically linked by a neurogenic inflammatory reflex involving TRPV1 and substance P.

    PubMed

    Guzmán, Mauricio; Miglio, Maximiliano S; Zgajnar, Nadia R; Colado, Ana; Almejún, María B; Keitelman, Irene A; Sabbione, Florencia; Fuentes, Federico; Trevani, Analía S; Giordano, Mirta N; Galletti, Jeremías G

    2018-06-04

    Immunological interdependence between the two eyes has been reported for the cornea and the retina but not for the ocular mucosal surface. Intriguingly, patients frequently report ocular surface-related symptoms in the other eye after unilateral ocular surgery. Here we show how unilateral eye injuries in mice affect the mucosal immune response of the opposite ocular surface. We report that, despite the lack of lymphatic cross-drainage, a neurogenic inflammatory reflex in the contralateral conjunctiva is sufficient to increase, first, epithelial nuclear factor kappa B signaling, then, dendritic cell maturation, and finally, expansion of effector, instead of regulatory, T cells in the draining lymph node, leading to disrupted ocular mucosal tolerance. We also show that damage to ocular surface nerves is required. Using pharmacological inhibitors and agonists, we identified transient receptor potential vanilloid 1 (TRPV1) channel as the receptor sensing tissue damage in the injured eye and substance P released in the opposite ocular surface as the effector of the sympathetic response. Finally, blocking either step prevented subsequent ocular allergic reactions in the opposite eye in a unilateral corneal alkali burn model. This study demonstrates that both ocular surfaces are immunologically linked and suggests potential therapeutic targets for intervention.

  11. Rebamipide suppresses PolyI:C-stimulated cytokine production in human conjunctival epithelial cells.

    PubMed

    Ueta, Mayumi; Sotozono, Chie; Yokoi, Norihiko; Kinoshita, Shigeru

    2013-09-01

    We previously documented that ocular surface epithelial cells could regulate ocular surface inflammation and suggested that, while Toll-like receptor 3 upregulates, EP3, one of the prostaglandin E2 receptors, downregulates ocular surface inflammation. Others reported that rebamipide, a gastroprotective drug, could not only increase the gastric mucus production, but also suppressed gastric mucosal inflammation and that it was dominantly distributed in mucosal tissues. The eyedrop form of rebamipide, approved in Japan for use in the treatment of dry eye diseases, upregulates mucin secretion and production, thereby suppressing superficial punctate keratopathy on the ocular surface of patients with this disease. In the current study, we investigated whether rebamipide has anti- inflammatory effects on the ocular surface. To examine the effects of rebamipide on polyI:C-induced cytokine expression by primary human conjunctival epithelial cells, we used enzyme-linked immunosorbent assay and quantitative reverse transcription-polymerase chain reaction assay. We studied the effects of rebamipide on ocular surface inflammation in our murine experimental allergic conjunctivitis (EAC) model. Rebamipide could suppress polyI:C-induced cytokine production and the expression of mRNAs for CXCL10, CXCL11, RANTES, MCP-1, and IL-6 in human conjunctival epithelial cells. In our EAC model, the topical administration of rebamipide suppressed conjunctival allergic eosinophil infiltration. The topical application of rebamipide on the ocular surface might suppress ocular surface inflammation by suppressing the production of cytokines by ocular surface epithelial cells.

  12. Ocular hydrofluoric acid burns: animal model, mechanism of injury and therapy.

    PubMed Central

    McCulley, J P

    1990-01-01

    A series of ocular HF burns was produced in rabbits in order to clarify the nature of the injury and to provide a description of the animal model. Burned eyes were evaluated clinically and allowed to progress for up to 65 days before histologic examination. The mechanism of HF toxicity was investigated through the study of burns produced by chemicals chosen to mimic its pH effects, osmotic effects, and effects of the free fluoride ion alone. The severe progressive caustic effect of HF on the eyes was found to depend on the combination of pH and the toxic effects of the free fluoride ion, together causing extensive dose-related damage to superficial and deep structures of the eye. Mild burns caused reversible ocular injury; whereas more severe burns lead to corneal stromal scarring, vascularization, edema, formation of calcific band keratopathy plus iris and ciliary body fibrosis. An investigation was made of potential treatments for experimental ocular HF burns in rabbits. Topical ointments containing MgO or MgSO4 and irrigations with or subconjunctival injections of H2O or solutions containing NaCl, MgCl2, CaCl2, LaCl3, hyamine, zephiran, calcium gluconate or a mixture of divalent metal ions were tested for toxicity and for therapeutic value in ocular HF burns. Immediate single irrigation with H2O, NaCl or MgCl2 solution was most effective. Other therapeutic agents commonly used in HF skin burn therapy were either too toxic in normal eyes or caused additive damage to burned eyes. Images FIGURE 1 FIGURE 6 FIGURE 7 FIGURE 8 PMID:2095035

  13. A comparative study of the usefulness of color vision, photostress recovery time, and visual evoked potential tests in early detection of ocular toxicity from hydroxychloroquine.

    PubMed

    Heravian, Javad; Saghafi, Massoud; Shoeibi, Naser; Hassanzadeh, Samira; Shakeri, Mohammad Taghi; Sharepoor, Maria

    2011-08-01

    Ocular toxicity from hydroxychloroquine (HCQ) is rare, but its potential permanence and severity makes it imperative to employ measures and screening protocols to minimize its occurrence. This study was performed to assess the usefulness of color vision, photo stress recovery time (PSRT), and visual evoked potentials (VEP) in early detection of ocular toxicity of HCQ, in patients with rheumatoid arthritis (RA) and systemic lupus erythematosus (SLE). 86 patients were included in the study and divided into three groups: (1) with history of HCQ use: interventional 1 (Int.1) without fundoscopic changes and Int.2 with fundoscopic changes; and (2) without history of HCQ use, as control. Visual field, color vision, PSRT and VEP results were recorded for all patients and the effect of age, disease duration, treatment duration and cumulative dose of HCQ on each test was assessed in each group. There was a significant relationship among PSRT and age, treatment duration, cumulative dose of HCQ and disease duration (P<0.001 for all). Color vision was normal in all the cases. P100 amplitude was not different between the three groups (P=0.846), but P100 latency was significantly different (P=0.025) and for Int.2 it was greater than the others. The percentage of abnormal visual fields for Int.2 was more than Int.1 and control groups (P=0.002 and P=0.005 respectively), but Int.1 and control groups were not significantly different (P>0.50). In the early stages of maculopathy, P100 latencies of VEP and PSRT are useful predictors of HCQ ocular toxicity. In patients without ocular symptoms and fundoscopic changes, the P100 latency of VEP predicts more precisely than the others.

  14. Emerging treatment paradigms of ocular surface disease: proceedings of the Ocular Surface Workshop.

    PubMed

    Rolando, M; Geerling, G; Dua, H S; Benítez-del-Castillo, J M; Creuzot-Garcher, C

    2010-01-01

    The objective of the Ocular Surface Workshop in Rome, Italy, on 6 February 2009, was to enhance the understanding of ocular surface disease (OSD) through an exploration of the nature of its complexities and current treatment paradigms across Europe. It was hoped that the peer-to-peer discussions and updates regarding common knowledge, clinical practices and shared experiences at this workshop would subsequently shape future treatment approaches to OSD.

  15. The natural history of Stevens–Johnson syndrome: patterns of chronic ocular disease and the role of systemic immunosuppressive therapy

    PubMed Central

    De Rojas, M Victoria; Dart, John K G; Saw, Valerie P J

    2007-01-01

    Objective To characterize patterns of chronic ocular disease in patients with Stevens–Johnson syndrome (SJS) and its variant toxic epidermal necrolysis (TEN), and to describe their response to treatment. Methods Retrospective case series. A review of hospital records of 30 patients (60 eyes) with ocular manifestations of SJS or TEN was carried out. The principal outcome measure was to identify and classify the patterns of chronic ocular disease in SJS and TEN. The secondary outcome measure was the response to treatment. Results Patterns of chronic ocular disease observed after the acute episode included: mild/moderate SJS, severe SJS, ocular surface failure (SJS‐OSF), recurrent episodic inflammation (SJS‐RI), scleritis (SJS‐S) and progressive conjunctival cicatrisation resembling mucous membrane pemphigoid (SJS‐MMP). The median follow‐up was 5 years (range 0–29). 19 patients (29 eyes (48%)) developed SJS‐OSF, SJS‐RI, SJS‐S or SJS‐MMP during follow‐up. SJS‐OSF was present in 12 patients (18 eyes (30%)). In 5 patients (eight eyes) this developed 1 year after the acute illness, without any further inflammatory episodes; it was associated with SJS‐RI in 1 patient (2 eyes), with SJS‐RI and SJS‐S in 1 patient (1 eye), with SJS‐S in 1 patient (1 eye) and with SJS‐MMP in 4 patients (6 eyes). Episodes of SJS‐RI occurred in 4 patients (7 eyes (12%)). The median time from acute disease to the first episode of SJS‐RI was 8.5 years (range 5–63). SJS‐S developed in 2 patients (4 eyes (7%)), of which 2 eyes subsequently developed SJS‐OSF. SJS‐MMP developed in 5 patients (10 eyes (16.6%)). The median duration from the acute stage to the diagnosis of SJS‐MMP was 2 years (range 1–14). Immunosuppressive therapy successfully controlled inflammation in 10/10 patients with SJS‐MMP, SJS‐RI or SJS‐S. Conclusion Ocular disease in SJS/TEN is not limited solely to the sequelae of the acute phase illness. Patients and physicians need to know that ocular disease progression, due to surface failure and/or acute inflammatory conditions, may occur at variable periods following the acute disease episode. Recognition of this, and prompt access to specialist services, may optimise management of these uncommon patterns of disease in SJS. PMID:17314145

  16. Ocular surface injury from a microwave superheated liquid.

    PubMed

    Gagnon, Michael R; Walter, Keith A

    2004-03-01

    To describe the ocular surface injury resulting from a microwave superheated liquid. Case report. A 40-year-old man sustained an ocular surface injury from a microwave superheated liquid. The injury resulted in limbal stem cell damage requiring an autograft limbal stem cell transplantation. We are unaware of previous reports of microwave superheated liquids resulting in ocular injury. Microwave superheating of liquids is a potential ocular danger that should be brought to the attention of both ophthalmologists and their patients.

  17. Ocular toxicity of authentic lunar dust

    PubMed Central

    2012-01-01

    Background Dust exposure is a well-known occupational hazard for terrestrial workers and astronauts alike and will continue to be a concern as humankind pursues exploration and habitation of objects beyond Earth. Humankind’s limited exploration experience with the Apollo Program indicates that exposure to dust will be unavoidable. Therefore, NASA must assess potential toxicity and recommend appropriate mitigation measures to ensure that explorers are adequately protected. Visual acuity is critical during exploration activities and operations aboard spacecraft. Therefore, the present research was performed to ascertain the ocular toxicity of authentic lunar dust. Methods Small (mean particle diameter = 2.9 ± 1.0 μm), reactive lunar dust particles were produced by grinding bulk dust under ultrapure nitrogen conditions. Chemical reactivity and cytotoxicity testing were performed using the commercially available EpiOcularTM assay. Subsequent in vivo Draize testing utilized a larger size fraction of unground lunar dust that is more relevant to ocular exposures (particles <120 μm; median particle diameter = 50.9 ± 19.8 μm). Results In vitro testing indicated minimal irritancy potential based on the time required to reduce cell viability by 50% (ET50). Follow-up testing using the Draize standard protocol confirmed that the lunar dust was minimally irritating. Minor irritation of the upper eyelids was noted at the 1-hour observation point, but these effects resolved within 24 hours. In addition, no corneal scratching was observed using fluorescein stain. Conclusions Low-titanium mare lunar dust is minimally irritating to the eyes and is considered a nuisance dust for ocular exposure. No special precautions are recommended to protect against ocular exposures, but fully shielded goggles may be used if dust becomes a nuisance. PMID:22817808

  18. Ocular toxicity of authentic lunar dust.

    PubMed

    Meyers, Valerie E; Garcìa, Hector D; Monds, Kathryn; Cooper, Bonnie L; James, John T

    2012-07-20

    Dust exposure is a well-known occupational hazard for terrestrial workers and astronauts alike and will continue to be a concern as humankind pursues exploration and habitation of objects beyond Earth. Humankind's limited exploration experience with the Apollo Program indicates that exposure to dust will be unavoidable. Therefore, NASA must assess potential toxicity and recommend appropriate mitigation measures to ensure that explorers are adequately protected. Visual acuity is critical during exploration activities and operations aboard spacecraft. Therefore, the present research was performed to ascertain the ocular toxicity of authentic lunar dust. Small (mean particle diameter = 2.9 ± 1.0 μm), reactive lunar dust particles were produced by grinding bulk dust under ultrapure nitrogen conditions. Chemical reactivity and cytotoxicity testing were performed using the commercially available EpiOcularTM assay. Subsequent in vivo Draize testing utilized a larger size fraction of unground lunar dust that is more relevant to ocular exposures (particles <120 μm; median particle diameter = 50.9 ± 19.8 μm). In vitro testing indicated minimal irritancy potential based on the time required to reduce cell viability by 50% (ET50). Follow-up testing using the Draize standard protocol confirmed that the lunar dust was minimally irritating. Minor irritation of the upper eyelids was noted at the 1-hour observation point, but these effects resolved within 24 hours. In addition, no corneal scratching was observed using fluorescein stain. Low-titanium mare lunar dust is minimally irritating to the eyes and is considered a nuisance dust for ocular exposure. No special precautions are recommended to protect against ocular exposures, but fully shielded goggles may be used if dust becomes a nuisance.

  19. Development and Characterization of a Microemulsion System Containing Amphotericin B with Potential Ocular Applications.

    PubMed

    da Silveira, Walteçá Louis Lima; Damasceno, Bolivar P G L; Ferreira, Laura F; Ribeiro, Izabel L S; Silva, Karolyne S; Silva, André Leandro; Giannini, Maria José Mendes; da Silva-Júnior, Arnóbio Antônio; de Oliveira, Anselmo Gomes; do Egito, E Sócrates Tabosa

    2016-01-01

    Amphotericin B eye drops are widely used in the treatment of ocular infections. However, amphotericin's toxicity leads to low patient compliance and aggravation of symptoms. This work describes the development of a microemulsion system containing amphotericin B, aiming for its use in ocular applications. The microemulsion was developed by the titration technique. The physicochemical characteristics were determined with both loaded and unloaded amphotericin B-microemulsion. The nanostructures were analyzed by polarized light microscopy. The microdilution method was used to establish the minimum inhibitory concentration against fungal strains, and, therefore, evaluate the microemulsion activity. Additionally, in order to evaluate the microemulsion toxicity an in vitro toxicity assay against red blood cells was performed. The performed studies showed that the presence of amphotericin B loaded into the system did not induce serious changes in the physicochemical properties of the microemulsion when compared to the unloaded system. The spectrophotometric studies depicted amphotericin B-self-associated species, which allow predicting its behavior in vitro. The high pressure liquid chromatography results revealed high drug content entrapment in the microemulsion droplet. Finally, the amphotericin B-microemulsion in vitro susceptibility test showed high activity against Candida strains and a low toxicity profile against red blood cells when compared to Fungizone®. The physicochemical characterization of the microemulsion demonstrated that its characteristics are compatible with the topical ocular route, making it eligible for consideration as a new and interesting amphotericin B-deliverydosage form to be used as eye drop formulation.

  20. In utero eyeball development study by magnetic resonance imaging.

    PubMed

    Brémond-Gignac, D S; Benali, K; Deplus, S; Cussenot, O; Ferkdadji, L; Elmaleh, M; Lassau, J P

    1997-01-01

    The aim of this study was to measure fetal ocular development and to determine a growth curve by means of measurements in utero. Fetal ocular development was recorded by analysis of the results of magnetic resonance imaging (MRI). An anatomic study allowed definition of the best contrasted MRI sequences for calculation of the ocular surface. Biometric analysis of the values of the ocular surface in the neuro-ocular plane in 35 fetuses allowed establishment of a linear model of ocular growth curve in utero. Evaluation of ocular development may allow the detection and confirmation of malformational ocular anomalies such as microphthalmia.

  1. Effect of benzalkonium chloride-free latanoprost ophthalmic solution on ocular surface in patients with glaucoma.

    PubMed

    Walimbe, Tejaswini; Chelerkar, Vidya; Bhagat, Purvi; Joshi, Abhijeet; Raut, Atul

    2016-01-01

    Benzalkonium chloride (BAK), included as a preservative in many topical treatments for glaucoma, induces significant toxicity and alters tear breakup time (TBUT). BAK-containing latanoprost, an ester prodrug of prostaglandin F2α, can cause ocular adverse events (AEs) associated with BAK. The purpose of this study was to evaluate the efficacy and safety of BAK-free latanoprost. A prospective, open-label, single-arm, multicenter, 8-week study in patients with primary open-angle glaucoma or ocular hypertension taking BAK-containing latanoprost for ≥12 months was performed. Patients were switched to BAK-free latanoprost ophthalmic solution 0.005% administered once daily, and eyes were assessed after 28 and 56 days. Primary efficacy and safety variables were TBUT and treatment-emergent AEs, respectively. At day 56, 40 eyes were evaluable. Mean TBUT increased significantly from baseline (3.67±1.60 seconds) to 5.03±2.64 and 6.06±3.39 seconds after 28 and 56 days of treatment with BAK-free latanoprost (P<0.0001). Ocular Surface Disease Index(©) (OSDI(©)) score also decreased significantly to 12.06±13.40 and 7.06±10.75 at 28 and 56 days, respectively, versus baseline (18.09±18.61, P<0.0001). In addition, inferior corneal staining score decreased significantly to 0.53 from baseline (0.85, P=0.0033). A reduction in conjunctival hyperemia and intraocular pressure was observed at both time points. No treatment-related serious AEs were evident and 12 (26.08%) treatment-emergent AEs occurred in seven patients, with eye pain and irritation being the most frequent. No clinically significant changes in vital signs or slit lamp examinations were observed. Results indicate that switching from BAK-containing latanoprost to BAK-free latanoprost resulted in significant improvements in TBUT, OSDI(©) score, and inferior corneal staining score, and measurable reductions in conjunctival hyperemia score. Furthermore, BAK-free latanoprost was well tolerated with only mild-to-moderate and self-limiting AEs. BAK-free latanoprost appears to be effective in protecting ocular surface integrity in glaucoma patients but further studies are needed to confirm this beneficial effect.

  2. Control of Cross Talk between Angiogenesis and Inflammation by Mesenchymal Stem Cells for the Treatment of Ocular Surface Diseases.

    PubMed

    Li, Fei; Zhao, Shao-Zhen

    2016-01-01

    Angiogenesis is beneficial in the treatment of ischemic heart disease and peripheral artery disease. However, it facilitates inflammatory cell filtration and inflammation cascade that disrupt the immune and angiogenesis privilege of the avascular cornea, resulting in ocular surface diseases and even vision loss. Although great progress has been achieved, healing of severe ocular surface injury and immunosuppression of corneal transplantation are the most difficult and challenging step in the treatment of ocular surface disorders. Mesenchymal stem cells (MSCs), derived from various adult tissues, are able to differentiate into different cell types such as endothelial cells and fat cells. Although it is still under debate whether MSCs could give rise to functional corneal cells, recent results from different study groups showed that MSCs could improve corneal disease recovery through suppression of inflammation and modulation of immune cells. Thus, MSCs could become a promising tool for ocular surface disorders. In this review, we discussed how angiogenesis and inflammation are orchestrated in the pathogenesis of ocular surface disease. We overviewed and updated the knowledge of MSCs and then summarized the therapeutic potential of MSCs via control of angiogenesis, inflammation, and immune response in the treatment of ocular surface disease.

  3. [Study of ocular surface electromyography signal analysis].

    PubMed

    Zhu, Bei; Qi, Li-Ping

    2009-11-01

    Test ocular surface electromyography signal waves and characteristic parameters to provide effective data for the diagnosis and treatment of ocular myopathy. Surface electromyography signals tests were performed in 140 normal volunteers and 30 patients with ophthalmoplegia. Surface electrodes were attached to medial canthi, lateral canthi and the middle of frontal bone. Then some alternate flashing red lamps were installed on perimeter to reduce the movement of eyeball. The computer hardware, software, and A/D adapter (12 Bit) were used. Sampling frequency could be selected within 40 kHz, frequency of amplifier was 2 kHz, and input short circuit noise was less than 3 microV. For normal volunteers, the ocular surface electromyography signals were regular, and the electric waves were similar between different sex groups and age groups. While for patients with ophthalmoplegia, the wave amplitude of ocular surface electromyography signals were declined or disappeared in the dyskinesia direction. The wave amplitude was related with the degree of pathological process. The characteristic parameters of patients with ophthalmoplegia were higher than normal volunteers. The figures of ocular surface electromyogram obtained from normal volunteers were obviously different with that from patients with ophthalmoplegia. This test can provide reliable quantized data for the diagnosis and treatment of ocular myopathy.

  4. Clusterin Seals the Ocular Surface Barrier in Mouse Dry Eye

    PubMed Central

    Bauskar, Aditi; Mack, Wendy J.; Mauris, Jerome; Argüeso, Pablo; Heur, Martin; Nagel, Barbara A.; Kolar, Grant R.; Gleave, Martin E.; Nakamura, Takahiro; Kinoshita, Shigeru; Moradian-Oldak, Janet; Panjwani, Noorjahan; Pflugfelder, Stephen C.; Wilson, Mark R.; Fini, M. Elizabeth; Jeong, Shinwu

    2015-01-01

    Dry eye is a common disorder caused by inadequate hydration of the ocular surface that results in disruption of barrier function. The homeostatic protein clusterin (CLU) is prominent at fluid-tissue interfaces throughout the body. CLU levels are reduced at the ocular surface in human inflammatory disorders that manifest as severe dry eye, as well as in a preclinical mouse model for desiccating stress that mimics dry eye. Using this mouse model, we show here that CLU prevents and ameliorates ocular surface barrier disruption by a remarkable sealing mechanism dependent on attainment of a critical all-or-none concentration. When the CLU level drops below the critical all-or-none threshold, the barrier becomes vulnerable to desiccating stress. CLU binds selectively to the ocular surface subjected to desiccating stress in vivo, and in vitro to the galectin LGALS3, a key barrier component. Positioned in this way, CLU not only physically seals the ocular surface barrier, but it also protects the barrier cells and prevents further damage to barrier structure. These findings define a fundamentally new mechanism for ocular surface protection and suggest CLU as a biotherapeutic for dry eye. PMID:26402857

  5. Clusterin Seals the Ocular Surface Barrier in Mouse Dry Eye.

    PubMed

    Bauskar, Aditi; Mack, Wendy J; Mauris, Jerome; Argüeso, Pablo; Heur, Martin; Nagel, Barbara A; Kolar, Grant R; Gleave, Martin E; Nakamura, Takahiro; Kinoshita, Shigeru; Moradian-Oldak, Janet; Panjwani, Noorjahan; Pflugfelder, Stephen C; Wilson, Mark R; Fini, M Elizabeth; Jeong, Shinwu

    2015-01-01

    Dry eye is a common disorder caused by inadequate hydration of the ocular surface that results in disruption of barrier function. The homeostatic protein clusterin (CLU) is prominent at fluid-tissue interfaces throughout the body. CLU levels are reduced at the ocular surface in human inflammatory disorders that manifest as severe dry eye, as well as in a preclinical mouse model for desiccating stress that mimics dry eye. Using this mouse model, we show here that CLU prevents and ameliorates ocular surface barrier disruption by a remarkable sealing mechanism dependent on attainment of a critical all-or-none concentration. When the CLU level drops below the critical all-or-none threshold, the barrier becomes vulnerable to desiccating stress. CLU binds selectively to the ocular surface subjected to desiccating stress in vivo, and in vitro to the galectin LGALS3, a key barrier component. Positioned in this way, CLU not only physically seals the ocular surface barrier, but it also protects the barrier cells and prevents further damage to barrier structure. These findings define a fundamentally new mechanism for ocular surface protection and suggest CLU as a biotherapeutic for dry eye.

  6. [Ocular surface system integrity].

    PubMed

    Safonova, T N; Pateyuk, L S

    2015-01-01

    The interplay of different structures belonging to either the anterior segment of the eye or its accessory visual apparatus, which all share common embryological, anatomical, functional, and physiological features, is discussed. Explanation of such terms, as ocular surface, lacrimal functional unit, and ocular surface system, is provided.

  7. A mouse dry eye model induced by topical administration of benzalkonium chloride.

    PubMed

    Lin, Zhirong; Liu, Xiaochen; Zhou, Tong; Wang, Yihui; Bai, Li; He, Hui; Liu, Zuguo

    2011-01-25

    To develop a dry eye model of mouse induced by topical administration of benzalkonium chloride (BAC) and investigate the possible mechanisms. BAC at concentration of 0.2% was applied to the mouse ocular surface for 7 days. Phenol red thread tear test, tear break-up time (BUT) test, corneal inflammatory index scoring, fluorescein and rose bengal test were performed to evaluate the toxic effects of BAC on the ocular surface. Global specimens were collected on day (D) 7 and labeled with a series of antibodies including cytokeratin 10 (K10) and mucin 5AC (MUC5AC). Apoptosis of ocular surface epithelium was evaluated by in situ terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. Histologic analysis and transmission electron microscopy (TEM) were performed on D7. BAC at a concentration of 0.2% successfully induced a dry eye condition with decreased tear volume and BUTs, increased corneal fluorescein and rose bengal scores. The Inflammatory index was increased in accompaniment with higher tumor necrosis factor-α (TNF-α) expression and more inflammatory infiltration in the cornea. Immunolabeling revealed positive K10 expression in BAC-treated corneal epithelium and fewer MUC5AC-positive cells in the BAC-treated conjunctival fornix. TUNEL assay showed more apoptotic cells in the corneal basal epithelium. TEM showed that the size and intervals of the microvillis were both reduced in the corneal epithelium. Topical administration of 0.2% BAC in mouse induces changes resembling that of dry eye syndrome in humans, and thus, represents a novel model of dry eye.

  8. A mouse dry eye model induced by topical administration of benzalkonium chloride

    PubMed Central

    Lin, Zhirong; Liu, Xiaochen; Zhou, Tong; Wang, Yihui; Bai, Li; He, Hui

    2011-01-01

    Purpose To develop a dry eye model of mouse induced by topical administration of benzalkonium chloride (BAC) and investigate the possible mechanisms. Methods BAC at concentration of 0.2% was applied to the mouse ocular surface for 7 days. Phenol red thread tear test, tear break-up time (BUT) test, corneal inflammatory index scoring, fluorescein and rose bengal test were performed to evaluate the toxic effects of BAC on the ocular surface. Global specimens were collected on day (D) 7 and labeled with a series of antibodies including cytokeratin 10 (K10) and mucin 5AC (MUC5AC). Apoptosis of ocular surface epithelium was evaluated by in situ terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. Histologic analysis and transmission electron microscopy (TEM) were performed on D7. Results BAC at a concentration of 0.2% successfully induced a dry eye condition with decreased tear volume and BUTs, increased corneal fluorescein and rose bengal scores. The Inflammatory index was increased in accompanyment with higher tumor necrosis factor-α (TNF-α) expression and more inflammatory infiltration in the cornea. Immunolabeling revealed positive K10 expression in BAC-treated corneal epithelium and fewer MUC5AC-positive cells in the BAC-treated conjunctival fornix. TUNEL assay showed more apoptotic cells in the corneal basal epithelium. TEM showed that the size and intervals of the microvillis were both reduced in the corneal epithelium. Conclusions Topical administration of 0.2% BAC in mouse induces changes resembling that of dry eye syndrome in humans, and thus, represents a novel model of dry eye. PMID:21283525

  9. Functions of ocular surface mucins in health and disease

    PubMed Central

    Mantelli, Flavio; Argüeso, Pablo

    2009-01-01

    Purpose of review The purpose of the present review is to describe new concepts on the role of mucins in the protection of corneal and conjunctival epithelia and to identify alterations of mucins in ocular surface diseases. Recent findings New evidence indicates that gel-forming and cell surface-associated mucins contribute differently to the protection of the ocular surface against allergens, pathogens, extracellular molecules, abrasive stress, and drying. Summary Mucins are high molecular weight glycoproteins characterized by their extensive O-glycosylation. Major mucins expressed by the ocular surface epithelia include cell surface-associated mucins MUC1, -4 and -16, and the gel-forming mucin MUC5AC. Recent advances using functional assays have allowed the examination of their roles in the protection of corneal and conjunctival epithelia. Alterations in mucin and mucin O-glycan biosynthesis in ocular surface disorders, including allergy, non-autoimmune dry eye, autoimmune dry eye, and infection, are presented. PMID:18769205

  10. Effects of ocular surface strontium-90 beta radiotherapy in dogs latently infected with canine herpesvirus-1.

    PubMed

    Nicklin, Amanda M; McEntee, Margaret C; Ledbetter, Eric C

    2014-12-05

    Latent canine herpesvirus-1 (CHV-1) infections are common in domestic dogs, but stimuli causing viral reactivation and recrudescent disease are poorly understood. Immunosuppressive pharmaceuticals are currently the only experimentally established triggers for recurrent ocular CHV-1 infection in dogs; however, ocular CHV-1 shedding has been reported clinically following strontium-90 beta radiotherapy of the ocular surface and it has been speculated that radiotherapy can directly induce viral reactivation. Strontium-90 is used as a beta radiation source for the treatment of a variety of neoplastic and immune-mediated canine ocular surface diseases. In the present study, the effects of ocular surface strontium-90 beta radiotherapy in dogs latently infected with CHV-1 were evaluated. Ten mature dogs with experimentally induced latent CHV-1 infections were randomly divided into two groups: one group received a single fraction 50 Gy radiation dose in one application from a strontium-90 ophthalmic applicator and the second group received sham radiotherapy. Dogs were then monitored for 45 days for recurrent ocular CHV-1 infection using clinical and virological outcome measures. Clinical ophthalmic examinations, ocular sample CHV-1 PCR assays, and serum CHV-1 virus neutralizing antibody assays were performed at specified intervals. No abnormalities suggestive of recurrent CHV-1 ocular disease were observed on clinical examination in any dog during the study. Ocular viral shedding was not detected and CHV-1 virus neutralizing titers remained stable in all dogs. A single fraction 50 Gy radiation dose administered to the ocular surface by strontium-90 beta radiotherapy did not result in detectable recurrent ocular CHV-1 infection in mature dogs with experimentally induced latent infection. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The enhancement of biological ocular UV radiation on beaches compared to the radiation on grass.

    PubMed

    Liu, Guang-Cong; Wang, Fang; Gao, Yan-Yan; Yang, Zheng; Hu, Li-Wen; Gao, Qian; Ri, Jun-Chol; Liu, Yang

    2014-12-01

    The influence of albedo on ocular UV exposure has seldom been reported. This paper aimed to explore the enhancement effect on measured ocular UV radiation due to a sand surface compared to measured ocular UV radiation due to a grass surface. We measured ambient and ocular UV radiation over the beach and grass surface in Sanya City of China (18.4°N, 109.7°E). The experimental apparatus was composed of a manikin and a dual-detector spectrometer. Integration of both UVA and UVB radiation was used to denote UV radiation. Then biologically effective ocular UVB radiation (UVBE) and the ratios of UVBE of two surfaces were calculated. Maximum of ocular UV radiation versus time over the two surfaces is bimodal. UVBE on the beach is significantly larger than UVBE on the sand, and UVBE peaked at different solar elevation angle (SEA) over the two surfaces (about 53° and 40° on the beach and grass, respectively, according to Bayesian regression). The maximum of ocular UVBE ratios is greater than two, which peaked SEA was about 50°. One hour's cumulative radiation under sunny weather exceeds thresholds for photokeratitis, conjunctivitis and lens damage. Higher albedo significantly increased biological ocular UV radiation. Tourists on tropical beaches should take protective measures and avoid facing the sun directly, especially when SEA is around 50°. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. In vitro and in vivo ocular safety and eye surface permanence determination by direct and Magnetic Resonance Imaging of ion-sensitive hydrogels based on gellan gum and kappa-carrageenan.

    PubMed

    Fernández-Ferreiro, Anxo; González Barcia, Miguel; Gil-Martínez, María; Vieites-Prado, Alba; Lema, Isabel; Argibay, Barbara; Blanco Méndez, José; Lamas, Maria Jesus; Otero-Espinar, Francisco Javier

    2015-08-01

    Gellan gum, kappa-carrageenan and alginates are natural polysaccharides able to interact with different cations that can be used to elaborate ion-activated in situ gelling systems for different uses. The interaction between fluid solutions of these polysaccharides and cations presents into the tear made these biopolymers very interesting to elaborate ophthalmic drug delivery systems. The main purpose of this study is to evaluate the ability of mixtures of these polymers to obtain ion-activated ophthalmic in situ gelling systems with optimal properties for ocular use. To achieve this purpose different proportion of the biopolymers were analyzed using a mixture experimental design evaluating their transparency, mechanical properties and bioadhesion in the absence and presence of simulated tear fluid. Tear induces a rapid sol-to-gel phase transition in the mixtures forming a consistent hydrogel. The solution composed by 80% of gellan gum and 20% kappa-carrageenan showed the best mechanical and mucoadhesive properties. This mixture was evaluated for rheological behavior, microstructure, cytotoxicity, acute corneal irritancy, ex-vivo and in vivo ocular toxicity and in vivo corneal contact time using Magnetic Resonance Images (MRI) techniques. Result indicates that the system is safe at ophthalmic level and produces an extensive ocular permanence higher than 6h. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Ocular surface reconstruction with a tissue-engineered nasal mucosal epithelial cell sheet for the treatment of severe ocular surface diseases.

    PubMed

    Kobayashi, Masakazu; Nakamura, Takahiro; Yasuda, Makoto; Hata, Yuiko; Okura, Shoki; Iwamoto, Miyu; Nagata, Maho; Fullwood, Nigel J; Koizumi, Noriko; Hisa, Yasuo; Kinoshita, Shigeru

    2015-01-01

    Severe ocular surface diseases (OSDs) with severe dry eye can be devastating and are currently some of the most challenging eye disorders to treat. To investigate the feasibility of using an autologous tissue-engineered cultivated nasal mucosal epithelial cell sheet (CNMES) for ocular surface reconstruction, we developed a novel technique for the culture of nasal mucosal epithelial cells expanded ex vivo from biopsy-derived human nasal mucosal tissues. After the protocol, the CNMESs had 4-5 layers of stratified, well-differentiated cells, and we successfully generated cultured epithelial sheets, including numerous goblet cells. Immunohistochemistry confirmed the presence of keratins 3, 4, and 13; mucins 1, 16, and 5AC; cell junction and basement membrane assembly proteins; and stem/progenitor cell marker p75 in the CNMESs. We then transplanted the CNMESs onto the ocular surfaces of rabbits and confirmed the survival of this tissue, including the goblet cells, up to 2 weeks. The present report describes an attempt to overcome the problems of treating severe OSDs with the most severe dry eye by treating them using tissue-engineered CNMESs to supply functional goblet cells and to stabilize and reconstruct the ocular surface. The present study is a first step toward assessing the use of tissue-engineered goblet-cell transplantation of nonocular surface origin for ocular surface reconstruction. ©AlphaMed Press.

  14. Current Perspectives of Prophylaxis and Management of Acute Infective Endophthalmitis.

    PubMed

    Tranos, Paris; Dervenis, Nikolaos; Vakalis, Athanasios N; Asteriadis, Solon; Stavrakas, Panagiotis; Konstas, Anastasios G P

    2016-05-01

    Endophthalmitis is an intraocular inflammatory condition which may or may not be caused by infective agents. Noninfectious (sterile) endophthalmitis may be attributable to various causes including postoperative retained soft lens matter or toxicity following introduction of other agents into the eye. Infectious endophthalmitis is further subdivided into endogenous and exogenous. In endogenous endophthalmitis there is hematogenous spread of organisms from a distant source of infection whereas in exogenous endophthalmitis direct microbial inoculation may occur usually following ocular surgery or penetrating eye injury with or without intraocular foreign bodies. Acute infective endophthalmitis is usually exogenous induced by inoculation of pathogens following ocular surgery, open-globe injury and intravitreal injections. More infrequently the infective source is internal and septicemia spreads to the eye resulting in endogenous endophthalmitis. Several risk factors have been implicated including immunosuppression, ocular surface abnormalities, poor surgical wound construction, complicated cataract surgery with vitreous loss and certain types of intraocular lens. Comprehensive guidelines and recommendations on prophylaxis and monitoring of surgical cases have been proposed to minimize the risk of acute endophthalmitis. Early diagnosis and prompt management of infective endophthalmitis employing appropriately selected intravitreal antibiotics are essential to optimize visual outcome.

  15. Risk of Adverse Health and Performance Effects of Celestial Dust Exposure

    NASA Technical Reports Server (NTRS)

    Scully, Robert R.; Meyers, Valerie E.

    2015-01-01

    Crew members can be directly exposed to celestial dust in several ways. After crew members perform extravehicular activities (EVAs), they may introduce into the habitat dust that will have collected on spacesuits and boots. Cleaning of the suits between EVAs and changing of the Environmental Control Life Support System filters are other operations that could result in direct exposure to celestial dusts. In addition, if the spacesuits used in exploration missions abrade the skin, as current EVA suits have, then contact with these wounds would provide a source of exposure. Further, if celestial dusts gain access to a suit's interior, as was the case during the Apollo missions, the dust could serve as an additional source of abrasions or enhance suit-induced injuries. When a crew leaves the surface of a celestial body and returns to microgravity, the dust that is introduced into the return vehicle will "float," thus increasing the opportunity for ocular and respiratory injury. Because the features of the respirable fraction of lunar dusts indicate they could be toxic to humans, NASA conducted several studies utilizing lunar dust simulants and authentic lunar dust to determine the unique properties of lunar dust that affect physiology, assess the dermal and ocular irritancy of the dust, and establish a permissible exposure limit for episodic exposure to airborne lunar dust during missions that would involve no more than 6 months stay on the lunar surface. Studies, with authentic lunar soils from both highland (Apollo 16) and mare (Apollo17) regions demonstrated that the lunar soil is highly abrasive to a high fidelity model of human skin. Studies of lunar dust returned during the Apollo 14 mission from an area of the moon in which the soils were comprised of mineral constituents from both major geological regions (highlands and mares regions) demonstrated only minimal ocular irritancy, and pulmonary toxicity that was less than the highly toxic terrestrial crystalline silica (Permissible Exposure Limit [PEL] 0.05 mg/m3) but more toxic than the nuisance dust titanium dioxide (TiO2 [PEL 5.0 mg/m3]). A PEL for episodic exposure to airborne lunar dust during a six-month stay on the lunar surface was established, in consultation with an independent, extramural panel of expert pulmonary toxicologists, at 0.3 mg/m3. The PEL provided for lunar dust is limited to the conditions and exposure specified therefore additional research remains to be accomplished with lunar dust to further address the issues of activation, address other areas of more unique lunar geology (Glotch et al., 2010; Greenhagen et al., 2010), examine potential toxicological effects of inhaled or ingested dust upon other organ systems, such cardiovascular, nervous systems, and examine effects of acute exposure to massive doses of dust such as may occur during off-nominal situations. Work to support the establishment of PELs for Martian dust and dusts of asteroids remains to be accomplished. The literature that describes health effects of exposure to toxic terrestrial dusts provides substantial basis for concern that prolonged exposure to respirable celestial dust could be detrimental to human health. Celestial bodies where a substantial portion of the dust is in the respirable range or where the dusts have large reactive surface areas or contain transition metals or volatile organics, represent greater risks of adverse effects from exposure to the dust. It is possible that in addition to adverse effects to the respiratory system, inhalation and ingestion of celestial dusts could pose risks to other systems

  16. Improvement of chronic corneal opacity in ocular surface disease with prosthetic replacement of the ocular surface ecosystem (PROSE) treatment.

    PubMed

    Cressey, Anna; Jacobs, Deborah S; Remington, Crystal; Carrasquillo, Karen G

    2018-06-01

    To demonstrate clearing of chronic corneal opacities and improvement of visual acuity with the use of BostonSight prosthetic replacement of the ocular surface ecosystem (PROSE) treatment in ocular surface disease. We undertook retrospective analysis of the medical records of a series of patients who underwent PROSE treatment from August 2006 to December 2014. Patients were referred for ocular surface disease of various etiologies. Primary inclusion criterion was corneal opacity that improved with PROSE treatment. Patients were excluded if topical steroids or adjuvant therapy used once PROSE treatment was initiated. Underlying disease, prior treatment, clinical presentation, and clinical course were extracted from the medical record. Four patients are included in this series. There were three females and one male; median age at time of treatment initiation was 30 years (range = 0.5-58 years). Median duration of PROSE treatment at time of retrospective analysis was 3.5 years (range = 1-8 years). Two cases had corneal opacification in the context of neurotrophic keratopathy: a unilateral case due to presumed herpes simplex keratitis and a bilateral case due to congenital corneal anesthesia associated with familial dysautonomia. One case had corneal opacity from exposure related to seventh nerve palsy, and one had corneal opacification associated with recurrent surface breakdown, neurotrophic keratopathy, and limbal stem deficiency of uncertain etiology. After consistent wear of prosthetic devices used in PROSE treatment for support of the ocular surface, visual acuity improved and clearing of the opacities was observed, without use of topical steroids or adjuvant therapy. These cases demonstrate clearing of chronic corneal opacity with PROSE treatment for ocular surface disease. This clearing can occur with no adjuvant therapy, suggesting that restoration of ocular surface function and integrity allows for corneal remodeling.

  17. Dry Eye Disease and Microbial Keratitis: Is There a Connection?

    PubMed Central

    Narayanan, Srihari; Redfern, Rachel L.; Miller, William L.; Nichols, Kelly K.; McDermott, Alison M.

    2013-01-01

    Dry eye is a common ocular surface disease of multifactorial etiology characterized by elevated tear osmolality and inflammation leading to a disrupted ocular surface. The latter is a risk factor for ocular surface infection, yet overt infection is not commonly seen clinically in the typical dry eye patient. This suggests that important innate mechanisms operate to protect the dry eye from invading pathogens. This article reviews the current literature on epidemiology of ocular surface infection in dry eye patients and laboratory-based studies on innate immune mechanisms operating at the ocular surface and their alterations in human dry eye and animal models. The review highlights current understanding of innate immunity in dry eye and identifies gaps in our knowledge to help direct future studies to further unravel the complexities of dry eye disease and its sequelae. PMID:23583043

  18. Structure and Biological Roles of Mucin-type O-glycans at the Ocular Surface

    PubMed Central

    Guzman-Aranguez, Ana; Argüeso, Pablo

    2010-01-01

    Mucins are major components in mucus secretions and apical cell membranes on wet-surfaced epithelia. Structurally, they are characterized by the presence of tandem repeat domains containing heavily O-glycosylated serine and threonine residues. O-glycans contribute to maintaining the highly extended and rigid structure of mucins, conferring to them specific physical and biological properties essential for their protective functions. At the ocular surface epithelia, mucin-type O-glycan chains are short and predominantly sialylated, perhaps reflecting specific requirements of the ocular surface. Traditionally, secreted mucins and their O-glycans in the tear film have been involved in the clearance of debris and pathogens from the surface of the eye. New evidence, however, shows that O-glycans on the cell-surface glycocalyx have additional biological roles in the protection of corneal and conjunctival epithelia, such as preventing bacterial adhesion, promoting boundary lubrication, and maintaining the epithelial barrier function through their interaction with galectin-3. Abnormalities in mucin-type O-glycosylation have been identified in many disorders where the stability of the ocular surface is compromised. This review summarizes recent advances in understanding the structure, biosynthesis, and function of mucin-type O-glycans at the ocular surface and their alteration in ocular surface disease. PMID:20105403

  19. Tear clearance implications for ocular surface health.

    PubMed

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  20. Oleoresin capsicum (Cap-Stun) toxicity from aerosol exposure.

    PubMed

    Watson, W A; Stremel, K R; Westdorp, E J

    1996-01-01

    To describe the clinical toxicity caused by oleoresin capsicum (OC) spray during law-enforcement action. A medical record review. Emergency department (ED), Truman Medical Center, Kansas City, MO. Consecutive patients who presented to the ED after OC-spray exposure from law-enforcement action between June 1991 and June 1994. Patient presentation and symptoms at presentation, evaluation, and treatment during ED stay. Eighty-one ED patients, approximately 10% of all individuals sprayed by police officers, presented after exposure to OC. Ocular burning and redness were the most common presenting symptoms. None of the patients required hospitalization due to OC toxicity. Corneal abrasions and respiratory symptoms occurred in 7 and 6 patients, respectively. The need for ED evaluation and treatment was infrequent after exposure to OC. A transient burning sensation, erythema, and localized irritation were the most common findings. While no patients had adverse outcomes attributed to OC exposure, practitioners assessing exposure should consider the potential for pulmonary and ocular toxicity.

  1. Coal dust contiguity-induced changes in the concentration of TNF- and NF- B p65 on the ocular surface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Z.Y.; Hong, J.; Liu, Z.Y.

    2009-07-01

    To observe the influence of coal dust on ocular surface of coal miners and rabbits with coal dust contiguity on expression TNF- and NF- Bp65 and dry eye occurrence. Expression TNF- and NF- Bp65 in ocular surface were determined. Results showed tear production, BUT and lysozyme decreased for coal miners and rabbits with coal dust contiguity. Coal dust exposure was linked to development of xerophthalmia, and induced a higher expression of NF- B p65 and TNF- perhaps as a mechanism to resist coal dust ocular surface injury.

  2. STANDARDS OF FUNCTIONAL MEASUREMENTS IN OCULAR TOXICOLOGY.

    EPA Science Inventory

    The visual system, like other sensory systems, may be a frequent target of exposure to toxic chemicals. A thorough evaluation of visual toxicity should include both structural and functional measures. Sensory evoked potentials are one set of neurophysiological procedures that...

  3. The Relation of Ocular Surface Irregularity and Visual Disturbance in Early Stage Acanthamoeba Keratitis.

    PubMed

    Matsumoto, Yukihiro; Kodama, Asako; Goto, Eiki; Kawakita, Tetsuya; Dogru, Murat; Tsubota, Kazuo

    2017-01-01

    To evaluate the relation between ocular surface irregularity and visual disturbance in early stage Acanthamoeba keratitis (AK). Fifteen patients with culture-proven AK underwent routine ophthalmic examinations, including best-corrected visual acuity (BCVA) measurement, slitlamp biomicroscope examination, and corneal fluorescein dye staining test, in both the eyes. We also evaluated the corneal sensitivity with Cochet-Bonnet esthesiometer, tear functions by Schirmer's test, and ocular surface irregularity by corneal topography and compared the results with the contralateral healthy eyes in this study. The mean logarithm of the minimum angle of resolution BCVA (0.71±0.77) was significantly lower in the eyes with AK (P=0.002). Epithelial disorders were present in all eyes, and radial keratoneuritis in 14 eyes (93.3%). The mean corneal sensitivity (39.3±24.1 mm) was significantly lower in eyes with AK compared with the healthy eyes (P=0.005). The mean Schirmer's test value (22.5±12.0 mm) in eyes with AK was significantly higher compared with the healthy eyes (P=0.01). The ocular surface irregularity indices (the surface regularity index, 2.47±0.42; the surface asymmetry index, 3.24±1.31) were significantly higher in eyes with AK compared with contralateral healthy eyes (P<0.0001 and P<0.0001, respectively). The ocular surface disease in AK is associated with decrease in corneal sensitivity and increase in Schirmer's test value and ocular surface irregularity indices. The visual disturbance in AK may owe not only to corneal haze but also to ocular surface irregularity.

  4. JBP485 promotes tear and mucin secretion in ocular surface epithelia

    PubMed Central

    Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru

    2015-01-01

    Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES. PMID:25996902

  5. JBP485 promotes tear and mucin secretion in ocular surface epithelia.

    PubMed

    Nakamura, Takahiro; Hata, Yuiko; Nagata, Maho; Yokoi, Norihiko; Yamaguchi, Shumpei; Kaku, Taiichi; Kinoshita, Shigeru

    2015-05-21

    Dry eye syndrome (DES), a multifactorial disease of the tears and ocular surface, is one of the most common ocular disorders. Tear film contains ocular mucins and is essential for maintaining the homeostasis of the wet ocular surface. Since there are a limited number of clinical options for the treatment of DES, additional novel treatments are needed to improve the clinical results. In this study, we found that placental extract-derived dipeptide (JBP485) clearly promoted the expression and secretion of gel-forming mucin 5ac (Muc5ac) in rabbit conjunctival epithelium. JBP485 also elevated the expression level of cell surface-associated mucins (Muc1/4/16) in rabbit corneal epithelium. The Schirmer tear test results indicated that JBP485 induced tear secretion in the rabbit model. Moreover, JBP485 clinically improved corneal epithelial damage in a mouse dry eye model. Thus, our data indicate that JBP485 efficiently promoted mucin and aqueous tear secretion in rabbit ocular surface epithelium and has the potential to be used as a novel treatment for DES.

  6. Restoring conjunctival tolerance by topical nuclear factor-κB inhibitors reduces preservative-facilitated allergic conjunctivitis in mice.

    PubMed

    Guzmán, Mauricio; Sabbione, Florencia; Gabelloni, María Laura; Vanzulli, Silvia; Trevani, Analía Silvina; Giordano, Mirta Nilda; Galletti, Jeremías Gastón

    2014-09-04

    To evaluate the role of nuclear factor-κB (NF-κB) activation in eye drop preservative toxicity and the effect of topical NF-κB inhibitors on preservative-facilitated allergic conjunctivitis. Balb/c mice were instilled ovalbumin (OVA) combined with benzalkonium chloride (BAK) and/or NF-κB inhibitors in both eyes. After immunization, T-cell responses and antigen-induced ocular inflammation were evaluated. Nuclear factor-κB activation and associated inflammatory changes also were assessed in murine eyes and in an epithelial cell line after BAK exposure. Benzalkonium chloride promoted allergic inflammation and leukocyte infiltration of the conjunctiva. Topical NF-κB inhibitors blocked the disruptive effect of BAK on conjunctival immunological tolerance and ameliorated subsequent ocular allergic reactions. In line with these findings, BAK induced NF-κB activation and the secretion of IL-6 and granulocyte-monocyte colony-stimulating factor in an epithelial cell line and in the conjunctiva of instilled mice. In addition, BAK favored major histocompatibility complex (MHC) II expression in cultured epithelial cells in an NF-κB-dependent fashion after interaction with T cells. Benzalkonium chloride triggers conjunctival epithelial NF-κB activation, which seems to mediate some of its immune side effects, such as proinflammatory cytokine release and increased MHC II expression. Breakdown of conjunctival tolerance by BAK favors allergic inflammation, and this effect can be prevented in mice by topical NF-κB inhibitors. These results suggest a new pharmacological target for preservative toxicity and highlight the importance of conjunctival tolerance in ocular surface homeostasis. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  7. Ocular manifestations of xeroderma pigmentosum: long term follow-up highlights the role of DNA repair in protection from sun damage

    PubMed Central

    Brooks, Brian P; Thompson, Amy H; Bishop, Rachel J; Clayton, Janine A; Chan, Chi-Chao; Tsilou, Ekaterini T; Zein, Wadih M; Tamura, Deborah; Khan, Sikandar G.; Ueda, Takahiro; Boyle, Jennifer; Oh, Kyu-Seon; Imoto, Kyoko; Inui, Hiroki; Moriwaki, Shin-Ichi; Emmert, Steffen; Iliff, Nicholas T.; Bradford, Porcia; DiGiovanna, John J.; Kraemer, Kenneth H

    2013-01-01

    Objective Xeroderma pigmentosum (XP) is a rare autosomal recessive disease caused by mutations in DNA repair genes. Clinical manifestations of XP include mild to extreme sensitivity to ultraviolet radiation resulting in inflammation and neoplasia in sun-exposed areas of the skin, mucous membranes, and ocular surfaces. This report describes the ocular manifestations of XP in patients systematically evaluated in the Clinical Center at the National Institutes of Health. Design Retrospective Observational Case Series Participants Eighty-seven participants, aged 1.3 to 63.4 years, referred to the National Eye Institute for examination from 1964 to 2011. Eighty-three had XP, 3 had XP/Cockayne Syndrome complex, and 1 had XP/trichothiodystrophy complex. Methods Complete, age- and developmental stage-appropriate ophthalmic examination. Main Outcome Measures Visual acuity; eyelid, ocular surface and lens pathology; tear film and tear production measures; and cytological analysis of conjunctival surface swabs. Results Of the 87 patients, 91% had at least one ocular abnormality. The most common abnormalities were conjunctivitis (51%), corneal neovascularization (44%), dry eye (38%), corneal scarring (26%), ectropion (25%), blepharitis (23%), conjunctival melanosis (20%), and cataracts (14%). Thirteen percent of patients had some degree of visual axis impingement and 5% had no light perception in one or both eyes. Ocular surface cancer or a history of ocular surface cancer was present in 10% of patients. Patients with an acute sunburning skin phenotype were less likely to develop conjunctival melanosis and ectropion but more likely to develop neoplastic ocular surface lesions than non-burning patients. Some patients also showed signs of limbal stem cell deficiency. Conclusions Our longitudinal study reports the ocular status of the largest group of XP patients systematically examined at one facility over an extended period of time. Structural eyelid abnormalities, neoplasms of the ocular surface and eyelids, tear film and tear production abnormalities, ocular surface disease and inflammation, as well as corneal abnormalities were present in this population. Burning and non-burning XP patients exhibit different rates of important ophthalmologic findings, including neoplasia. Additionally, ophthalmic characteristics can help refine diagnoses in the case of XP complex phenotypes. DNA repair plays major role in protection of the eye from sunlight induced damage. PMID:23601806

  8. The surface activity of purified ocular mucin at the air-liquid interface and interactions with meibomian lipids.

    PubMed

    Millar, Thomas J; Tragoulias, Sophia T; Anderton, Philip J; Ball, Malcolm S; Miano, Fausto; Dennis, Gary R; Mudgil, Poonam

    2006-01-01

    Ocular mucins are thought to contribute to the stability of the tear film by reducing surface tension. The purpose of this study was to compare the effect of different mucins and hyaluronic acid (HA) alone and mixed with meibomian lipids on the surface pressure at an air-liquid interface. A Langmuir trough and Wilhelmy balance were used to measure and compare the surface activity of bovine submaxillary gland mucin (BSM), purified BSM, purified bovine ocular mucin and HA, and mixtures of these with meibomian lipids, phosphatidylcholine, and phosphatidylglycerol. Their appearance at the surface of an air-buffer interface was examined using epifluorescence microscopy. Purified ocular mucin had no surface activity even at concentrations that were 100 times more than normally occur in tears. By contrast, commercial BSM caused changes to surface pressure that were concentration dependent. The surface pressure-area profiles showed surface activity with maximum surface pressures of 12.3-22.5 mN/m depending on the concentration. Purified BSM showed no surface activity at low concentrations, whereas higher concentrations reached a maximum surface pressure of 25 mN/m. HA showed no surface activity, at low or high concentrations. Epifluorescence showed that the mucins were located at the air-buffer interface and changed the appearance of lipid films. Purified bovine ocular mucin and HA have no surface activity. However, despite having no surface activity in their own right, ocular mucins are likely to be present at the surface of the tear film, where they cause an increase in surface pressure by causing a compression of the lipids (a reorganization of the lipids) and alter the viscoelastic properties at the surface.

  9. Targeted delivery of hyaluronic acid to the ocular surface by a polymer-peptide conjugate system for dry eye disease.

    PubMed

    Lee, David; Lu, Qiaozhi; Sommerfeld, Sven D; Chan, Amanda; Menon, Nikhil G; Schmidt, Tannin A; Elisseeff, Jennifer H; Singh, Anirudha

    2017-06-01

    Hyaluronic acid (HA) solutions effectively lubricate the ocular surface and are used for the relief of dry eye related symptoms. However, HA undergoes rapid clearance due to limited adhesion, which necessitates frequent instillation. Conversely, highly viscous artificial tear formulations with HA blur vision and interfere with blinking. Here, we developed an HA-eye drop formulation that selectively binds and retains HA for extended periods of time on the ocular surface. We synthesized a heterobifunctional polymer-peptide system with one end binding HA while the other end binding either sialic acid-containing glycosylated transmembrane molecules on the ocular surface epithelium, or type I collagen molecule within the tissue matrix. HA solution was mixed with the polymer-peptide system and tested on both ex vivo and in vivo models to determine its ability to prolong HA retention. Furthermore, rabbit ocular surface tissues treated with binding peptides and HA solutions demonstrated superior lubrication with reduced kinetic friction coefficients compared to tissues treated with conventional HA solution. The results suggest that binding peptide-based solution can keep the ocular surface enriched with HA for prolonged times as well as keep it lubricated. Therefore, this system can be further developed into a more effective treatment for dry eye patients than a standard HA eye drop. Eye drop formulations containing HA are widely used to lubricate the ocular surface and relieve dry eye related symptoms, however its low residence time remains a challenge. We designed a polymer-peptide system for the targeted delivery of HA to the ocular surface using sialic acid or type I collagen as anchors for HA immobilization. The addition of the polymer-peptide system to HA eye drop exhibited a reduced friction coefficient, and it can keep the ocular surface enriched with HA for prolonged time. This system can be further developed into a more effective treatment for dry eye than a standard HA eye drop. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Aniridia and Brachmann-de Lange syndrome: a review of ocular surface and anterior segment findings.

    PubMed

    Lee, W Barry; Brandt, James D; Mannis, Mark J; Huang, Charles Q; Rabin, Gregory J

    2003-03-01

    To review the ocular surface and anterior segment findings in Brachmann-de Lange syndrome and describe a new case involving aniridia and congenital glaucoma. A newborn presented 2 days after birth with bilateral cloudy corneas, photophobia, and epiphora. We provide a 5-year descriptive history and clinical course with review of the literature on Brachmann-de Lange syndrome. Multiple ocular surgeries were performed for ocular sequelae from aniridia and congenital glaucoma including Ahmed valve placement and penetrating keratoplasties in both eyes. At 5.5 years of age, the child had a clear graft OD and amblyopia from graft failure OS following recurrent graft infections. A review of Brachmann-de Lange syndrome found 43 patients with ocular surface and anterior segment findings. The most common findings included conjunctivitis, blepharitis, microcornea, and corectopia. Aniridia and congenital glaucoma were not previously reported with Brachmann-de Lange syndrome. Ocular surface and anterior segment abnormalities must be considered when examining patients with Brachmann-de Lange syndrome. Ocular findings may include vision-threatening anomalies, as in our case with aniridia and congenital glaucoma. To our knowledge, these findings are previously unreported in Brachmann-de Lange syndrome.

  11. Dry eye disease: an immune-mediated ocular surface disorder

    PubMed Central

    Stevenson, William; Chauhan, Sunil K.; Dana, Reza

    2013-01-01

    Dry eye disease is a multifactorial disorder of the tears and ocular surface characterized by symptoms of dryness and irritation. Although the pathogenesis of dry eye disease is not fully understood, it is recognized that inflammation has a prominent role in the development and propagation of this debilitating condition. Factors that adversely affect tear film stability and osmolarity can induce ocular surface damage and initiate an inflammatory cascade that generates innate and adaptive immune responses. These immunoinflammatory responses lead to further ocular surface damage and the development of a self-perpetuating inflammatory cycle. Herein, we review the fundamental links between inflammation and dry eye disease and discuss the clinical implications of inflammation in disease management. PMID:22232476

  12. Accounting for Ethnicity-Related Differences in Ocular Surface Integrity as a Step Toward Understanding Contact Lens Discomfort.

    PubMed

    Chan, Stefanie M; Svitova, Tatyana F; Lin, Meng C

    2017-01-01

    Contact lens discomfort is a common problem that can lead to unsuccessful or limited contact lens wear. Although many factors may contribute to contact lens discomfort, limited research has explored the influence of ethnicity-related differences in the anatomy and physiology of the ocular surface. Therefore, we performed a search of the literature in PubMed using key words related to "ocular surface" paired with the terms "race" and "ethnicity." The goal of this review was to determine potential areas of research regarding ethnicity differences, particularly between Asian and non-Asian eyes, in ocular surface integrity to advance our understanding of contact lens discomfort.

  13. A comparative study of a preservative-free latanoprost cationic emulsion (Catioprost) and a BAK-preserved latanoprost solution in animal models.

    PubMed

    Daull, Philippe; Buggage, Ronald; Lambert, Grégory; Faure, Marie-Odile; Serle, Janet; Wang, Rong-Fang; Garrigue, Jean-Sébastien

    2012-10-01

    Benzalkonium chloride (BAK), a common preservative in eye drops, can induce ocular surface toxicity that may decrease glaucoma therapy compliance. The ocular hypotensive effect, pharmacokinetic (PK) profiles, and local tolerance of a preservative-free latanoprost 0.005% cationic emulsion (Catioprost(®)), and a BAK-preserved latanoprost 0.005% solution (Xalatan(®)), were compared. The ocular hypotensive effect was evaluated in monkeys with elevated intraocular pressure (IOP) induced by laser photocoagulation of the trabecular meshwork. Each monkey (n=8) received both latanoprost formulations once daily for 5 consecutive treatment days in a crossover design with at least a 2-week washout period between treatments. IOP was measured at baseline (on day 1, no instillation), on vehicle treatment day (day 0), and on treatment days 1, 3, and 5 before drug instillation and then hourly for 6 h. In rabbits, the ocular and systemic concentrations of latanoprost free acid were determined following a single instillation and the local tolerance of twice daily instillations over 28 days was assessed. Both the preservative-free and BAK-preserved latanoprost formulations shared the same efficacy profile with the maximum IOP reduction occurring 2 h after each morning dose (-15%, -20%, and -26%; -15%, -23%, and -23% on days 1, 3, and 5, respectively) and lasting through 24 h. The equivalence in efficacy was confirmed by the PK data demonstrating similar area under the curves (AUCs). While both formulations were well tolerated, the incidence of conjunctival hyperemia was reduced by 42% with the BAK-free latanoprost cationic emulsion. In animal models, a preservative-free latanoprost cationic emulsion was as effective as Xalatan(®) for lowering IOP with an improved ocular tolerance profile.

  14. SFTA3 - a novel surfactant protein of the ocular surface and its role in corneal wound healing and tear film surface tension.

    PubMed

    Schicht, Martin; Garreis, Fabian; Hartjen, Nadine; Beileke, Stephanie; Jacobi, Christina; Sahin, Afsun; Holland, Detlef; Schröder, Henrik; Hammer, Christian M; Paulsen, Friedrich; Bräuer, Lars

    2018-06-28

    The study aimed to characterize the expression and function of SFTA3 at the ocular surface and in tears. Ocular tissues, conjunctival (HCjE) and human corneal (HCE) epithelial cell lines as well as tearfilm of patients suffering from different forms of dry eye disease (DED) were analyzed by means of RT-PCR, western blot, immunohistochemistry, and ELISA. A possible role of recombinant SFTA3 in corneal wound healing was investigated performing in vitro scratch assays. Tear film regulatory properties were analyzed with the spinning drop method and the regulation of SFTA3 transcripts was studied in HCE and HCjE after incubation with proinflammatory cytokines as well as typical ocular pathogens by real-time RT-PCR and ELISA. The results reveal that human ocular tissue as well as tears of healthy volunteers express SFTA3 whereas tears from patients with DED showed significantly increased SFTA3 levels. In vitro wounding of HCE cell cultures that had been treated with recombinant SFTA3 demonstrated a significantly increased wound closure rate and rSFTA3 reduced the surface tension of tear fluid. The results indicate that SFTA3 at the ocular surface seemed to be involved in wound healing and the reduction of surface tension.

  15. Interfacial Interaction between Transmembrane Ocular Mucins and Adhesive Polymers and Dendrimers Analyzed by Surface Plasmon Resonance

    PubMed Central

    Noiray, M.; Briand, E.; Woodward, A. M.; Argüeso, P.; Molina Martínez, I. T.; Herrero-Vanrell, R.; Ponchel, G.

    2013-01-01

    Purpose Development of the first in vitro method based on biosensor chip technology designed for probing the interfacial interaction phenomena between transmembrane ocular mucins and adhesive polymers and dendrimers intended for ophthalmic administration. Methods The surface plasmon resonance (SPR) technique was used. A transmembrane ocular mucin surface was prepared on the chip surface and characterized by QCM-D (Quartz Crystal Microbalance with Dissipation) and XPS (X-ray photoelectron spectroscopy). The mucoadhesive molecules tested were: hyaluronic acid (HA), carboxymethyl cellulose (CMC), hydroxypropylmethyl cellulose (HPMC), chitosan (Ch) and polyamidoamine dendrimers (PAMAM). Results While Ch originated interfacial interaction with ocular transmembrane mucins, for HA, CMC and HPMC, chain interdiffusion seemed to be mandatory for bioadherence at the concentrations used in ophthalmic clinical practise. Interestingly, PAMAM dendrimers developed permanent interfacial interactions with transmembrane ocular mucins whatever their surface chemical groups, showing a relevant importance of co-operative effect of these multivalent systems. Polymers developed interfacial interactions with ocular membrane-associated mucins in the following order: Ch(1 %) > G4PAMAM-NH2(2 %) = G4PAMAM-OH(2 %) > G3.5PAMAM-COOH(2 %)≫ CMC(0.5 %) = HA(0.2 %) = HPMC(0.3 %). Conclusions The method proposed is useful to discern between the mucin-polymer chemical interactions at molecular scale. Results reinforce the usefulness of chitosan and den-drimers as polymers able to increase the retention time of drugs on the ocular surface and hence their bioavailability. PMID:22565639

  16. Ophthalmic Manifestations of Xeroderma Pigmentosum: A Perspective from the United Kingdom.

    PubMed

    Lim, Rongxuan; Sethi, Mieran; Morley, Ana M S

    2017-11-01

    To document the ocular manifestations of xeroderma pigmentosum (XP), presenting via the United Kingdom (UK) XP service, and to analyze the correlations between XP genotype and ophthalmic phenotype. Prospective observational case series. Eighty-nine patients seen by the UK Nationally Commissioned XP Service, from April 2010 to December 2014, with a genetically confirmed diagnosis of XP. Patients underwent a full ophthalmic examination at each visit. Clinical features from both eyes were recorded on a standard proforma. The most recent assessments were analyzed. A 2-tailed Fisher exact test was used to assess for differences in ocular features between patients in XP subgroups with impaired transcription coupled nucleotide excision repair (TC-NER) (category 1: XP-A, B, D, F, and G) and preserved TC-NER (category 2: XP-C, E, and V). Lid and periocular abnormalities, ocular surface pathologies, neuro-ophthalmologic abnormalities, lens and retinal abnormalities, and visual acuity (VA). Ninety-three percent of XP patients in our cohort had ocular involvement, with 65% describing photophobia. The most common abnormalities were in the periocular skin and ocular surface, including interpalpebral conjunctival melanosis (44%) and conjunctival injection (43%). Eleven percent of patients had required treatment for periocular cancers and 2% for ocular surface cancers. The most common neuro-ophthalmologic finding was minimal pupillary reaction to light (25%). Patients in category 2 had significantly more ocular surface abnormalities than patients in category 1, including a greater proportion of conjunctival injection (P = 0.003), conjunctival corkscrew vessels (P < 0.001), corneal scarring (P = 0.01) and pingueculae under the age of 50 (P = 0.02). Meanwhile, patients in category 1 had a higher proportion of poorly reactive pupils (P < 0.001) and abnormal ocular movements (P = 0.03) compared with those in category 2. Five patients (6%) presented to ophthalmologists with ocular surface signs related to XP, before any formal diagnosis of XP was made. A large proportion of XP patients have ocular involvement. Regular examination by an ophthalmologist is essential, especially in screening for eyelid and ocular surface tumors. The ocular phenotype-genotype segregation within XP patients suggests that XP is a heterogeneous and complex disease. With further study, we hope to offer these patients more individualized patient care. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. The ocular surface and tear film and their dysfunction in dry eye disease.

    PubMed

    Rolando, M; Zierhut, M

    2001-03-01

    The ocular surface, tear film, lacrimal glands, and eyelids act as a functional unit to preserve the quality of the refractive surface of the eye and to resist injury and protect the eye against changing bodily and environmental conditions. Events that disturb the homeostasis of this functional unit can result in a vicious cycle of ocular surface disease. The tear film is the most dynamic structure of the functional unit, and its production and turnover is essential to maintaining the health of the ocular surface. Classically, the tear film is reported to be composed of three layers: the mucin, aqueous, and lipid layers. The boundaries and real thickness of such layers is still under discussion. A dysfunction of any of these layers can result in dry eye disease.

  18. Quercetin and the ocular surface: What we know and where we are going

    PubMed Central

    McKay, Tina B

    2017-01-01

    Flavonoids are a class of plant and fungus secondary metabolites that serve functional roles in protecting against UV-induced oxidative stress, mediating auxin signaling, and promoting microbial defense. Flavonoids are extremely abundant in nature where their potent antioxidant capacity and very low toxicity makes them highly attractive as potential therapeutic agents. In terms of clinical applications, neither the Food and Drug Administration (FDA) nor the European Food Safety Authority (EFSA) has approved any health claims or drugs related to the use of flavonoids for therapeutic purposes. Quercetin is a common flavonol that has been shown to have potent antioxidant, anti-inflammatory, and anti-fibrotic activities both in vitro and in vivo in various tissues. Recently, the application of quercetin as a therapeutic has been gaining attention in the ocular surface scientific community in the study of dry eye, keratoconus, inflammation, and neovascularization of the cornea. This review will discuss the latest findings and the use of quercetin for the treatment of dystrophies of the ocular surface. Impact statement The eye represents a small portion of the human body, accounting for one decimal fraction of the anterior body surface. The cornea is an avascular, transparent tissue that acts as a primary barrier against mechanical and infectious damaging agents, protecting the internal structures of the eye. Corneal survival and function are affected by a number of factors including but not limited to injury, trauma, infection, genetics, and environment. Corneal injury, or trauma, often leads to loss of corneal transparency and even blindness. The concept of “curing” corneal opacity has been discussed in published form for over 200 years. Currently, full corneal transplant is the only treatment option. There is a strong interest in developing natural therapeutic products that come with minimum side effects. A novel antioxidant flavonoid, quercetin, has been gaining traction as a potential therapeutic to prevent the injured cornea. This review discusses the potential of this antioxidant. PMID:28056553

  19. Quercetin and the ocular surface: What we know and where we are going.

    PubMed

    McKay, Tina B; Karamichos, Dimitrios

    2017-03-01

    Flavonoids are a class of plant and fungus secondary metabolites that serve functional roles in protecting against UV-induced oxidative stress, mediating auxin signaling, and promoting microbial defense. Flavonoids are extremely abundant in nature where their potent antioxidant capacity and very low toxicity makes them highly attractive as potential therapeutic agents. In terms of clinical applications, neither the Food and Drug Administration (FDA) nor the European Food Safety Authority (EFSA) has approved any health claims or drugs related to the use of flavonoids for therapeutic purposes. Quercetin is a common flavonol that has been shown to have potent antioxidant, anti-inflammatory, and anti-fibrotic activities both in vitro and in vivo in various tissues. Recently, the application of quercetin as a therapeutic has been gaining attention in the ocular surface scientific community in the study of dry eye, keratoconus, inflammation, and neovascularization of the cornea. This review will discuss the latest findings and the use of quercetin for the treatment of dystrophies of the ocular surface. Impact statement The eye represents a small portion of the human body, accounting for one decimal fraction of the anterior body surface. The cornea is an avascular, transparent tissue that acts as a primary barrier against mechanical and infectious damaging agents, protecting the internal structures of the eye. Corneal survival and function are affected by a number of factors including but not limited to injury, trauma, infection, genetics, and environment. Corneal injury, or trauma, often leads to loss of corneal transparency and even blindness. The concept of "curing" corneal opacity has been discussed in published form for over 200 years. Currently, full corneal transplant is the only treatment option. There is a strong interest in developing natural therapeutic products that come with minimum side effects. A novel antioxidant flavonoid, quercetin, has been gaining traction as a potential therapeutic to prevent the injured cornea. This review discusses the potential of this antioxidant.

  20. Protecting the ocular surface and improving the quality of life of dry eye patients: a study of the efficacy of an HP-guar containing ocular lubricant in a population of dry eye patients.

    PubMed

    Rolando, Maurizio; Autori, Silvia; Badino, Francesco; Barabino, Stefano

    2009-06-01

    The aim of this study was to evaluate the efficacy of a non-Newtonian tear substitute containing 0.4% polyethylene glycol 400 (PEG 400) and 0.3% propylene glycol in an 0.18% hydroxypropyl-guar (HPG) containing vehicle (Systane Lubricant Eye Drops; Alcon) in reducing the signs and symptoms of dry eye, as well as its effect on ocular protection. Twenty patients with moderate to severe dry eye were enrolled in a 28-day prospective, randomized, controlled study. Subjects self-administered the HPG containing ocular lubricant four times daily (QID) over the study duration. After 28 days, the effect of the HPG containing ocular lubricant was evaluated by means of the Global Staining Score (a measure of the corneal and conjunctival staining), inter-blink tear film stability, Ocular Protection Index (OPI), and subjective symptoms. The HPG containing ocular lubricant produced statistically significant improvements compared with baseline in dry eye symptoms (P < 0.0001 at Days 7, 14, and 28); in ocular surface staining, as measured by a reduction in the Global Staining Score (P < 0.0001 at Days 7, 14, and 28); and in the OPI (P = 0.0025 at Day 14 and P = 0.0067 at Day 28). The improvements in ocular surface staining and dry eye symptoms with the HPG containing ocular lubricant -- evident as early as the first follow-up visit (Day 7) and continued throughout the 28 days of the study with a concurrent, increase in OPI to a level greater than unity -- indicate that this preparation is a fast-acting, long-lasting, and effective treatment for dry eye. In concurrence with the results from previously published clinical studies, the HPG containing ocular lubricant has shown efficacy in alleviating the signs and symptoms of dry eye as well as affording improved ocular surface protection.

  1. Virulence properties of multidrug resistant ocular isolates of Acinetobacter baumannii.

    PubMed

    Talreja, Deepa; Muraleedharan, Chithra; Gunathilaka, Gayathri; Zhang, Yifan; Kaye, Keith S; Walia, Satish K; Kumar, Ashok

    2014-07-01

    Acinetobacter (A.) baumannii is an opportunistic pathogen and has been reported as a causative agent of ocular infections. The aim of this study is to identify virulence properties (biofilm formation, adhesion, invasion and cytotoxicity) and antibiotic resistance among A. baumannii isolates recovered from the eye. The Microscan Walk-Away®, an automated bacterial identification and susceptibility testing system was used to determine antibiotic resistance. Clonal relatedness was assessed by Pulsed-field gel electrophoresis (PFGE) and plasmid profile analysis. Conjugation experiments were carried out to determine the transfer of antibiotic resistance genes and PCR was used to confirm gene transfer. Virulence properties of the isolates were determined by biofilm formation using crystal violet and immunofluorescence staining, adherence and internalization using cultured corneal epithelial cells, and cytotoxicity by TUNEL-staining and LDH release assays. All ocular isolates (n = 12) exhibited multidrug resistant (MDR) phenotype and one of the isolate (AB12) was resistant to 18 antibiotics (β-lactam, aminoglycosides, tetracycline, chloramphenicol and quinolones). The plasmid profile analysis showed the presence of multiple plasmids in each isolate and a total of 10 different profiles were observed. However, PFGE analysis was more discriminatory which revealed 12 distinct genotypes. Antibiotic resistance (tetracycline and quinolone) was transferable from the isolate AB12 to a recipient Escherichia coli J53. Ten isolates were strong biofilm producers and the remaining two (AB5 and AB7) were moderate producers. All isolates demonstrated adherence and invasive properties towards HCECs. A similar trend was observed in their ability to cause cell death and toxicity. Our results indicate that ocular isolates of A. baumannii are biofilm producers and adherent and invasive to corneal epithelium, a first step in the pathogenesis of ocular infection. In addition, they demonstrated plasmid-mediated transfer of MDR traits making them a reservoir of resistance genes at ocular surface.

  2. The Relationship Between Ocular Itch, Ocular Pain, and Dry Eye Symptoms (An American Ophthalmological Society Thesis).

    PubMed

    Galor, Anat; Small, Leslie; Feuer, William; Levitt, Roy C; Sarantopoulos, Konstantinos D; Yosipovitch, Gil

    2017-08-01

    To evaluate associations between sensations of ocular itch and dry eye (DE) symptoms, including ocular pain, and DE signs. A cross-sectional study of 324 patients seen in the Miami Veterans Affairs eye clinic was performed. The evaluation consisted of questionnaires regarding ocular itch, DE symptoms, descriptors of neuropathic-like ocular pain (NOP), and evoked pain sensitivity testing on the forehead and forearm, followed by a comprehensive ocular surface examination including corneal mechanical sensitivity testing. Analyses were performed to examine for differences between those with and without subjective complaints of ocular itch. The mean age was 62 years with 92% being male. Symptoms of DE and NOP were more frequent in patients with moderate-severe ocular itch compared to those with no or mild ocular itch symptoms. With the exception of ocular surface inflammation (abnormal matrix metalloproteinase 9 testing) which was less common in those with moderate-severe ocular itch symptoms, DE signs were not related to ocular itch. Individuals with moderate-severe ocular itch also demonstrated greater sensitivity to evoked pain on the forearm and had higher non-ocular pain, depression, and post-traumatic stress disorders scores, compared to those with no or mild itch symptoms. Subjects with moderate-severe ocular itch symptoms have more severe symptoms of DE, NOP, non-ocular pain and demonstrate abnormal somatosensory testing in the form of increased sensitivity to evoked pain at a site remote from the eye, consistent with generalized hypersensitivity.

  3. The Relationship Between Ocular Itch, Ocular Pain, and Dry Eye Symptoms (An American Ophthalmological Society Thesis)

    PubMed Central

    Galor, Anat; Small, Leslie; Feuer, William; Levitt, Roy C.; Sarantopoulos, Konstantinos D.; Yosipovitch, Gil

    2017-01-01

    Purpose To evaluate associations between sensations of ocular itch and dry eye (DE) symptoms, including ocular pain, and DE signs. Methods A cross-sectional study of 324 patients seen in the Miami Veterans Affairs eye clinic was performed. The evaluation consisted of questionnaires regarding ocular itch, DE symptoms, descriptors of neuropathic-like ocular pain (NOP), and evoked pain sensitivity testing on the forehead and forearm, followed by a comprehensive ocular surface examination including corneal mechanical sensitivity testing. Analyses were performed to examine for differences between those with and without subjective complaints of ocular itch. Results The mean age was 62 years with 92% being male. Symptoms of DE and NOP were more frequent in patients with moderate-severe ocular itch compared to those with no or mild ocular itch symptoms. With the exception of ocular surface inflammation (abnormal matrix metalloproteinase 9 testing) which was less common in those with moderate-severe ocular itch symptoms, DE signs were not related to ocular itch. Individuals with moderate-severe ocular itch also demonstrated greater sensitivity to evoked pain on the forearm and had higher non-ocular pain, depression, and post-traumatic stress disorders scores, compared to those with no or mild itch symptoms. Conclusions Subjects with moderate-severe ocular itch symptoms have more severe symptoms of DE, NOP, non-ocular pain and demonstrate abnormal somatosensory testing in the form of increased sensitivity to evoked pain at a site remote from the eye, consistent with generalized hypersensitivity. PMID:29391860

  4. Crystalline maculopathy: a rare complication of tamoxifen therapy.

    PubMed

    Srikantia, Nirmala; Mukesh, S; Krishnaswamy, Malavika

    2010-01-01

    Tamoxifen is a selective estrogen receptor modulator widely used in the treatment of hormone-responsive breast cancer. Tamoxifen-induced ocular complications are very rare. A post-menopausal woman, diagnosed and treated case of carcinoma of left breast, on follow-up presented with history of gradual diminution of vision in both eyes of 3 months duration. Patient was on tamoxifen therapy 20 mg daily for the last 2 years. Fundus examination showed crystalline maculopathy. Fluorescein angiography, ocular coherence tomography confirmed the diagnosis. Tamoxifen therapy was discontinued. Although ocular toxicity is rare, careful evaluation of patients with visual symptoms on tamoxifen therapy is required.

  5. Homoisoflavonoids as potential antiangiogenic agents for retinal neovascularization.

    PubMed

    Amin, Sk Abdul; Adhikari, Nilanjan; Gayen, Shovanlal; Jha, Tarun

    2017-11-01

    A number of people worldwide have been suffering from ocular neovascularization that may be treated by a variety of drugs but these may possess adverse effects. Therefore, small antiangiogenic molecules with higher potency and lower toxic effects are intended. However, homoisoflavonoids of natural origin show the potential antiangiogenic effect in ocular neovascularization. These homoisoflavonoids are judged quantitatively in terms of statistical validation through multi-chemometric modeling approaches for the betterment and refinement of their structures required for higher antiangiogenic activity targeted to ocular neovascularization. These approaches may be utilized to design better antiangiogenic homoisoflavonoids. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Two Patients with Dry Eye Disease Followed Up Using an Expression Assay of Ocular Surface Mucin.

    PubMed

    Machida, Yumiko; Shoji, Jun; Harada, Natsuko; Inada, Noriko

    2016-01-01

    We report 2 patients with dry eye disease followed up using the expression levels of ocular surface mucin. Patient 1: a 57-year-old woman with Sjögren's syndrome-associated dry eyes experienced severe dryness and foreign body sensation in both her eyes, and instilled sodium hyaluronate ophthalmic solution 0.3% about 10-15 times daily. We measured the expression levels of MUC5AC mRNA (MUC5AC) and MUC16 mRNA (MUC16) by using real-time reversed transcription polymerase chain reaction for the specimens of modified impression cytology. Expression levels of MUC5AC and MUC16 on her ocular surface were very low. Subjective symptoms and expression levels of ocular surface mucin improved after combined treatment of rebamipide (4 times daily) and fluorometholone (once daily) ophthalmic suspension. Patient 2: a 62-year-old man with chronic graft-versus-host disease-associated dry eye experienced severe foreign body sensation and developed superficial punctate keratopathy with mucous thread and filamentary keratitis. Expression level of MUC5AC was very high at baseline. Subjective symptoms and expression levels of ocular surface mucin improved by combined treatment of rebamipide (4 times daily) and fluorometholone (once daily) ophthalmic suspension. Clinical test for MUC gene expression on the ocular surface was found to be useful in the follow-up of dry eye treatment.

  7. Ocular toxicity of beta-blockers and benzalkonium chloride in pigmented rabbits: electrophysiological and morphological studies.

    PubMed

    Chou, A; Hori, S; Takase, M

    1985-01-01

    Subconjunctival injection of 0.2 ml of the following solutions was carried out once a day for two weeks in the albino and pigmented rabbit: commercial 0.5% timolol or 1% befunolol ophthalmic solutions, both containing benzalkonium chloride, and also these drug solutions containing no preservative, ophthalmic base solutions containing benzalkonium chloride, physiological saline solution or phosphate buffer solution. One week after daily injections of the commercial drug solutions or base solutions with benzalkonium chloride, the electroretinogram (ERG) showed a marked reduction in the a- and b-wave amplitudes in the pigmented rabbit, but the ERG changes were slight in the albino rabbit. After two weeks of injections, histological studies of the pigmented rabbit eyes revealed retinal detachment, visual cell loss and atrophy of the retinal pigment epithelium and choroid; the changes in the albino rabbit eyes were minimal. Injections of the beta-blockers containing no benzalkonium resulted in no significant changes in the ERG or in the tissue structures of all rabbits. Injections of only physiological saline or phosphate buffer had no deleterious effects. Therefore, the ocular toxicity of the beta-blockers was thought to be minor and the toxic effects seen in this study were thought to be due to benzalkonium chloride, which possibly accumulates in the ocular pigments.

  8. IMRT for Sinonasal Tumors Minimizes Severe Late Ocular Toxicity and Preserves Disease Control and Survival

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duprez, Frederic, E-mail: frederic.duprez@ugent.be; Madani, Indira; Morbee, Lieve

    2012-05-01

    Purpose: To report late ocular (primary endpoint) and other toxicity, disease control, and survival (secondary endpoints) after intensity-modulated radiotherapy (IMRT) for sinonasal tumors. Methods and Materials: Between 1998 and 2009, 130 patients with nonmetastatic sinonasal tumors were treated with IMRT at Ghent University Hospital. Prescription doses were 70 Gy (n = 117) and 60-66 Gy (n = 13) at 2 Gy per fraction over 6-7 weeks. Most patients had adenocarcinoma (n = 82) and squamous cell carcinoma (n = 23). One hundred and one (101) patients were treated postoperatively. Of 17 patients with recurrent tumors, 9 were reirradiated. T-stages weremore » T1-2 (n = 39), T3 (n = 21), T4a (n = 38), and T4b (n = 22). Esthesioneuroblastoma was staged as Kadish A, B, and C in 1, 3, and 6 cases, respectively. Results: Median follow-up was 52, range 15-121 months. There was no radiation-induced blindness in 86 patients available for late toxicity assessment ({>=}6 month follow-up). We observed late Grade 3 tearing in 10 patients, which reduced to Grade 1-2 in 5 patients and Grade 3 visual impairment because of radiation-induced ipsilateral retinopathy and neovascular glaucoma in 1 patient. There was no severe dry eye syndrome. The worst grade of late ocular toxicity was Grade 3 (n = 11), Grade 2 (n = 31), Grade 1 (n = 33), and Grade 0 (n = 11). Brain necrosis and osteoradionecrosis occurred in 6 and 1 patients, respectively. Actuarial 5-year local control and overall survival were 59% and 52%, respectively. On multivariate analysis local control was negatively affected by cribriform plate and brain invasion (p = 0.044 and 0.029, respectively) and absence of surgery (p = 0.009); overall survival was negatively affected by cribriform plate and orbit invasion (p = 0.04 and <0.001, respectively) and absence of surgery (p = 0.001). Conclusions: IMRT for sinonasal tumors allowed delivering high doses to targets at minimized ocular toxicity, while maintaining disease control and survival. Avoidance of severe dry eye syndrome and radiation-induced blindness suggests IMRT as a standard treatment for sinonasal tumors.« less

  9. Solid lipid nanoparticles for ocular drug delivery.

    PubMed

    Seyfoddin, Ali; Shaw, John; Al-Kassas, Raida

    2010-01-01

    Ocular drug delivery remains challenging because of the complex nature and structure of the eye. Conventional systems, such as eye drops and ointments, are inefficient, whereas systemic administration requires high doses resulting in significant toxicity. There is a need to develop novel drug delivery carriers capable of increasing ocular bioavailability and decreasing both local and systemic cytotoxicity. Nanotechnology is expected to revolutionize ocular drug delivery. Many nano-structured systems have been employed for ocular drug delivery and yielded some promising results. Solid lipid nanoparticles (SLNs) have been looked at as a potential drug carrier system since the 1990s. SLNs do not show biotoxicity as they are prepared from physiological lipids. SLNs are especially useful in ocular drug delivery as they can enhance the corneal absorption of drugs and improve the ocular bioavailability of both hydrophilic and lipophilic drugs. SLNs have another advantage of allowing autoclave sterilization, a necessary step towards formulation of ocular preparations. This review outlines in detail the various production, characterization, sterilization, and stabilization techniques for SLNs. In-vitro and in-vivo methods to study the drug release profile of SLNs have been explained. Special attention has been given to the nature of lipids and surfactants commonly used for SLN production. A summary of previous studies involving the use of SLNs in ocular drug delivery is provided, along with a critical evaluation of SLNs as a potential ocular delivery system.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Wenhu, E-mail: wenhu.huang@pfizer.com; Collette, Walter; Twamley, Michelle

    Retinal ocular toxicity is among the leading causes of drug development attrition in the pharmaceutical industry. Electroretinography (ERG) is a non-invasive functional assay used to assess neuro-retinal physiological integrity by measuring the electrical responses. To directly assess the utility of ERG, a series of studies was conducted following intravitreal and/or iv administration of pan-cyclin-dependent kinase inhibitors: AG-012,986 and AG-024,322 in rats. Both compounds have previously shown to induce retinal toxicity. Retinal injury was evaluated by ERG, histopathology and TUNEL staining. Intravitreal injection of AG-012,986 at ≥ 10 μg/eye resulted in decreases (60%) in ERG b-wave and microscopic changes of mildmore » to moderate retinal degeneration, and at 30 μg/eye led to additional ophthalmic findings. Intravenous administration of AG-012,986 daily at ≥ 5 mg/kg resulted in dose-related decreases (25 to 40%) in b-wave and sporadic to intense positive TUNEL staining. Intravitreal injection of AG-024,322 at 30 μg/eye also resulted in decreases (50 to 60%) in b-wave, mild to marked retinal degeneration and mild vitreous debris. These experiments demonstrate that ERG can be used as a sensitive and reliable functional tool to evaluate retinal toxicity induced by test compounds in rats complementing other classical ocular safety measurements. - Highlights: • There were strong correlations of ERG readouts to in vivo ophthalmic exams, TUNEL assay, and histopathology. • ERG appears to be more sensitive and can detect retinal functional changes at a very early stage of pathogenesis. • ERG can be incorporated into routine exploratory toxicity study to identify compound ocular safety issues. • In drug discovery, ERG is a quick, non-invasive, sensitive and reliable tool in retinal toxicity de-risking.« less

  11. Development of a second-generation novel UVR sensor for the quantification of the light field at the anterior ocular surface

    NASA Astrophysics Data System (ADS)

    Fleming, David; Walsh, James E.; Moore, Linda; Bergmanson, Jan P. G.; McMahon, David

    2005-06-01

    Research has shown in recent years that acute and cumulative exposure to excessive ultraviolet radiation (UVR) can cause a range of degenerative ocular conditions such as pterygium, photokeratitis and pinguecula. The increase in natural solar UVR as a result of the depletion of the ozone layer has led to a greater awareness of the adverse effects of UVR on the anterior ocular surface tissues. The relevance of this lies in the fact that these tissues are not immune to photodamage and that there is selective absorption of UVR by conjunctival and corneal tissue in the anterior ocular surface. Therefore, there is a demand for more precise quantification and localisation of UVR incidence at the anterior ocular surface. A novel solar blind photodiode sensor array has been designed, constructed and tested for this purpose. The emphasis of the measurements made by this sensor system is the acquisition of real time, field based surveys of the ocular UVR light field in a broad range of insolation environments. These data will then provide a thorough database of UVR irradiances that can be related to induced damage of anterior ocular tissue. Results to date show the first measured, in-vivo, absolute UVR levels on the eye, the corresponding relative field across the eye and the presence of nasal-temporal biases that exist.

  12. Tear film and ocular surface assessment in psoriasis.

    PubMed

    Aragona, Emanuela; Rania, Laura; Postorino, Elisa Imelde; Interdonato, Alberto; Giuffrida, Roberta; Cannavò, Serafinella Patrizia; Puzzolo, Domenico; Aragona, Pasquale

    2018-03-01

    Psoriasis is a skin disease with also systemic involvement: its impact on the eye is not well established and often clinically underestimated. Aim of this study was to investigate the presence of ocular discomfort symptoms and of ocular surface changes in a population of patients with psoriasis. For this cross-sectional, comparative study, 66 patients with psoriasis were subdivided according to the presence of arthritis and to the use of biological therapy. All patients underwent clinical evaluation with the following tests: Ocular Surface Disease Index Questionnaire, Tearscope examination, meibometry, tear film breakup time, corneal and conjunctival fluorescein staining, Schirmer I test, corneal aesthesiometry, meibomian gland dysfunction (MGD) assessment and conjunctival impression cytology. 28 healthy subjects were also enrolled and treated with the same clinical tests. A statistical analysis of the results was performed. Patients with psoriasis showed a significant deterioration of the ocular surface tests, if compared with healthy subjects, demonstrated by tear film lipid layer alteration, tear film instability, corneal and conjunctival epithelial suffering and mild squamous metaplasia at impression cytology. No differences were found in ocular surface test results of the psoriatic group when patients were divided according to the presence of arthritis, whereas the anti-inflammatory treatment with biological drugs demonstrated a significant improvement of corneal stain and MGD. Our findings suggest that the ocular surface involvement in patients with psoriasis indicates the need of periodic ophthalmological examinations to diagnose the condition and allow a proper treatment, so contributing to the amelioration of patients' quality of life. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Limitations of an ocular surface inflammatory biomarker in impression cytology specimens.

    PubMed

    Yafawi, Rolla; Ko, Mira; Sace, Frederick P; John-Baptiste, Annette

    2013-03-01

    A number of ocular conditions, such as dry eye, are associated with inflammation on the surface of the eye leading to irritation and ocular pain. Many drugs such as chemotherapeutics, beta blockers, angiotensin-converting enzymes and so forth also cause dry eye but currently there are no validated ocular surface biomarkers available. We evaluated sample stability, assay sensitivity, reproducibility and overall performance of impression cytology (IC) utilizing the cellular surface biomarker human leukocyte antigen DR-1 (HLA-DR) as an ocular surface inflammatory biomarker by flow cytometry in a fit-for-purpose validation study. Additionally, subjects classified as normal or having various degrees of dry eye were evaluated to determine if HLA-DR could demonstrate a clear separation between normal and dry eye samples. The assay demonstrated high dynamic range detecting a broad range of fluorescent intensities in healthy donors. Additionally, inter, intra and stability assay results demonstrated strong concordance and low variability. Overall CV% for both assays were less than 25% for all measured parameters. However, high variability was observed for donor samples assayed beyond day 10 post IC sample collection (4.2-110.8 CV%). HLA-DR expression demonstrated a progressive increase in patients with mild to severe levels of dry eye disease providing sufficient evidence it is sensitive enough to monitor inflammatory effects of dry eye when coupled with additional biomarkers and/or methodologies such as cytokine analysis or ICAM-1. This biomarker can be used to monitor ocular surface disorders in patients and to evaluate potential treatment options during drug development. Although our results demonstrate this methodology is reproducible for routine evaluation, limitations around sample integrity exist. The ocular cell surface inflammatory biomarker, HLA-DR coupled with impression cytology is a simple non-invasive robust, specific and reproducible assay that can be utilized to measure inflammatory infiltrates on the surface of the eye in IC samples less than 10-days old.

  14. Modeling of mouse eye and errors in ocular parameters affecting refractive state

    NASA Astrophysics Data System (ADS)

    Bawa, Gurinder

    Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.

  15. Ocular surface immunity: homeostatic mechanisms and their disruption in dry eye disease.

    PubMed

    Barabino, Stefano; Chen, Yihe; Chauhan, Sunil; Dana, Reza

    2012-05-01

    The tear film, lacrimal glands, corneal and conjunctival epithelia and Meibomian glands work together as a lacrimal functional unit (LFU) to preserve the integrity and function of the ocular surface. The integrity of this unit is necessary for the health and normal function of the eye and visual system. Nervous connections and systemic hormones are well known factors that maintain the homeostasis of the ocular surface. They control the response to internal and external stimuli. Our and others' studies show that immunological mechanisms also play a pivotal role in regulating the ocular surface environment. Our studies demonstrate how anti-inflammatory factors such as the expression of vascular endothelial growth factor receptor-3 (VEGFR-3) in corneal cells, immature corneal resident antigen-presenting cells, and regulatory T cells play an active role in protecting the ocular surface. Dry eye disease (DED) affects millions of people worldwide and negatively influences the quality of life for patients. In its most severe forms, DED may lead to blindness. The etiology and pathogenesis of DED remain largely unclear. Nonetheless, in this review we summarize the role of the disruption of afferent and efferent immunoregulatory mechanisms that are responsible for the chronicity of the disease, its symptoms, and its clinical signs. We illustrate current anti-inflammatory treatments for DED and propose that prevention of the disruption of immunoregulatory mechanisms may represent a promising therapeutic strategy towards controlling ocular surface inflammation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Scleral Lenses in the Management of Corneal Irregularity and Ocular Surface Disease.

    PubMed

    Shorter, Ellen; Harthan, Jennifer; Nau, Cherie B; Nau, Amy; Barr, Joseph T; Hodge, David O; Schornack, Muriel M

    2017-09-29

    To describe current practice patterns regarding the use of scleral lens therapy in the management of corneal irregularity and ocular surface disease among eye care providers who fit scleral lenses. The Scleral Lenses in Current Ophthalmic Practice: an Evaluation (SCOPE) study group conducted an electronic survey of eye care providers from January 15 to March 31, 2015. Respondents ranked management options for corneal irregularity in the order in which they would generally consider their use. Respondents also ranked options for the management of ocular surface disease in the order in which they would use each of the treatments. Results for each option were analyzed as percentage first-place ranking; percentage first-, second-, or third-place ranking; and mean rank score. Survey responses were obtained from 723 providers who had fit 5 or more scleral lenses. Of these respondents, 629 ranked options for management of corneal irregularity and 612 ranked options for management of ocular surface disease. Corneal rigid gas-permeable lenses were the first option for management of corneal irregularity for 44% of respondents, and scleral lenses were the first option for 34% of respondents. Lubricant drops were the first therapeutic recommendation for ocular surface disease for 84% of respondents, and scleral lenses were ranked first by 6% of respondents. Scleral lenses rank second only to corneal rigid gas-permeable lenses for management of corneal irregularity. Scleral lenses are generally considered after other medical intervention and before surgery for the management of ocular surface disease.

  17. Ocular Surface Immunity: Homeostatic Mechanisms and Their Disruption in Dry Eye Disease

    PubMed Central

    Barabino, Stefano; Chen, Yihe; Chauhan, Sunil; Dana, Reza

    2012-01-01

    The tear film, lacrimal glands, corneal and conjunctival epithelia and Meibomian glands work together as a lacrimal functional unit (LFU) to preserve the integrity and function of the ocular surface. The integrity of this unit is necessary for the health and normal function of the eye and visual system. Nervous connections and systemic hormones are well known factors that maintain the homeostasis of the ocular surface. They control the response to internal and external stimuli. Our and others’ studies show that immunological mechanisms also play a pivotal role in regulating the ocular surface environment. Our studies demonstrate how anti-inflammatory factors such as the expression of vascular endothelial growth factor receptor-3 (VEGFR-3) in corneal cells, immature corneal resident antigen-presenting cells, and regulatory T cells play an active role in protecting the ocular surface. Dry eye disease (DED) affects millions of people worldwide and negatively influences the quality of life for patients. In its most severe forms, DED may lead to blindness. The etiology and pathogenesis of DED remain largely unclear. Nonetheless, in this review we summarize the role of the disruption of afferent and efferent immunoregulatory mechanisms that are responsible for the chronicity of the disease, its symptoms, and its clinical signs. We illustrate current anti-inflammatory treatments for DED and propose that prevention of the disruption of immunoregulatory mechanisms may represent a promising therapeutic strategy towards controlling ocular surface inflammation. PMID:22426080

  18. Functional anatomy and immunological interactions of ocular surface and adnexa.

    PubMed

    Paulsen, Friedrich

    2008-01-01

    This chapter gives an overview about the structures and physiology of the ocular surface and its adnexa and focuses in a second part on the possible meaning of eye-associated lymphoid tissue (EALT) in a context with the development of dry eye. Sections deal with (1) anatomy of the ocular surface, lacrimal gland, eyelid and nasolacrimal ducts. (2) The meaning and importance of the lacrimal functional unit and the function of the mucosal innate immune system are briefly summarized. (3) Finally, the occurrence and the possible function of EALT is discussed with regard to tolerance induction and dry eye. The epithelial surface of the eye and its specialized glandular infoldings produce the components of the tear film, which include water, protective antimicrobials, cytokines, lipids as well as mucins and trefoil factor family (TFF) peptides. Antimicrobials, mucins and TFF peptides perform a number of essential functions which, collectively, provide protection of the ocular surface. Their production changes in cases of dry eye. The development of EALT is a common feature frequently occurring in symptomatically normal conjunctiva and nasolacrimal ducts. The production of antimicrobials, mucins and TFF peptides can be linked with cell signaling, tear film rheology, and antimicrobial defense at the ocular surface. Changes in the production of such peptides and proteins in cases of dry eye support the assumption that these peptides and proteins are involved in the pathophysiological events that occur at the ocular surface and lacrimal apparatus. Whether special types of bacteria, viruses, or other factors, e.g., immune deviation, are responsible for the development of EALT in humans requires further investigation in prospective and experimental studies.

  19. [Ocular Surface Evaluation in Patients Treated with Prostaglandin Analogues Considering Preservative Agent].

    PubMed

    Mlčáková, E; Mlčák, P; Karhanová, M; Langová, K; Marešová, K

    The aim of this study was to evaluate the ocular surface in patients treated with prostaglandin analogues considering contained preservative agent. 60 patients with glaucoma or ocular hypertension treated with prostaglandin analogue monotherapy were enrolled in this observational study. 20 patients with glaucoma suspect or ocular hypertension without local or systemic glaucoma medication formed the control group. Demographic data and medical history were recorded for each participant. Patients filled in the Ocular surface disease index© (OSDI) questionnaire and underwent an ophthalmological examination including assessment of conjunctival hyperaemia according to Efron, tear film break up time (BUT) and fluorescein staining according to the Oxford grading scheme. Treated participants were divided into 3 groups according to the preservative contained in the currently used prostaglandin analogue: the preservative-free group (18 patients), the polyquaternium group (17 patients) and the benzalkonium chloride (BAK) group (25 patients). The control group had significantly lower fluorescein staining than the preservative-free group (p=0.001), the polyquaternium group (p=0.007) and the BAK group (p=0.002). The conjunctival hyperaemia was significantly lower in the preservative-free group compared to the polyquaternium group (p=0.011). There was no significant difference among the other groups. The difference neither in the OSDI score nor in the BUT was statistically important. This study confirmed that the ocular surface is worse in patients treated with prostaglandin analogue monotherapy than in people without glaucoma medication. A significant difference among treated patients depending on a preservative agent was not proved.Key words: benzalkonium chloride, glaucoma, ocular surface disease, preservatives, prostaglandin analogues.

  20. Dry eye syndrome: developments and lifitegrast in perspective

    PubMed Central

    Lollett, Ivonne V; Galor, Anat

    2018-01-01

    Dry eye (DE) is a chronic ocular condition with high prevalence and morbidity. It has a complex pathophysiology and is multifactorial in nature. Chronic ocular surface inflammation has emerged as a key component of DE that is capable of perpetuating ocular surface damage and leading to symptoms of ocular pain, discomfort, and visual phenomena. It begins with stress to the ocular surface leading to the production of proinflammatory mediators that induce maturation of resident antigen-presenting cells which then migrate to the lymph nodes to activate CD4 T cells. The specific antigen(s) targeted by these pathogenic CD4+ T cells remains unknown. Two emerging theories include self-antigens by autoreactive CD4 T cells or harmless exogenous antigens in the setting of mucosal immunotolerance loss. These CD4 T cells migrate to the ocular surface causing additional inflammation and damage. Lifitegrast is the second topical anti-inflammatory agent to be approved by the US Food and Drug Administration for the treatment of DE and the first to show improvement in DE symptoms. Lifitegrast works by blocking the interaction between intercellular adhesion molecule-1 and lymphocyte functional associated antigen-1, which has been shown to be critical for the migration of antigen-presenting cells to the lymph nodes as well as CD4+ T cell activation and migration to the ocular surface. In four large multicenter, randomized controlled trials, lifitegrast has proven to be effective in controlling both the signs and symptoms of DE with minimal side effects. Further research should include comparative and combination studies with other anti-inflammatory therapies used for DE. PMID:29391773

  1. Defensins and Other Antimicrobial Peptides at the Ocular Surface

    PubMed Central

    McDermott, Alison M.

    2006-01-01

    Although constantly exposed to the environment and “foreign bodies” such as contact lenses and unwashed fingertips, the ocular surface succumbs to infection relatively infrequently. This is, in large part, due to a very active and robust innate immune response mounted at the ocular surface. Studies over the past 20 years have revealed that small peptides with antimicrobial activity are a major component of the human innate immune response system. The ocular surface is no exception, with peptides of the defensin and cathelicidin families being detected in the tear film and secreted by corneal and conjunctival epithelial cells. There is also much evidence to suggest that the role of some antimicrobial peptides is not restricted to direct killing of pathogens, but, rather, that they function in various aspects of the immune response, including recruitment of immune cells, and through actions on dendritic cells provide a link to adaptive immunity. A role in wound healing is also supported. In this article, the properties, mechanisms of actions and functional roles of antimicrobial peptides are reviewed, with particular emphasis on the potential multifunctional roles of defensins and LL-37 (the only known human cathelicidin) at the ocular surface. PMID:17216098

  2. Polyclonality of Staphylococcus epidermidis residing on the healthy ocular surface.

    PubMed

    Ueta, Mayumi; Iida, Tetsuya; Sakamoto, Masako; Sotozono, Chie; Takahashi, Junko; Kojima, Kentaro; Okada, Kazuhisa; Chen, Xiuhao; Kinoshita, Shigeru; Honda, Takeshi

    2007-01-01

    Staphylococcus epidermidis is part of the normal bacterial flora on the ocular surface. The chromosomal DNA of bacterial isolates obtained from the conjunctival sac, upper and lower lid margins, and upper and lower Meibomian glands of healthy volunteers was subjected to SmaI digestion and PFGE to study the genetic diversity of the organisms. Multiple colonies were also examined of S. epidermidis derived from the conjunctival sac of the same subjects. Lastly, commensal bacteria were harvested from the ocular surfaces of four healthy subjects once a month for 6 months, and the genetic background of the S. epidermidis isolates was analysed. It was found that bacterial strains not only from different subjects but also from multiple ocular surface sites of the same subject exhibited different PFGE patterns. In five of 42 subjects multiple colonies of S. epidermidis were isolated from the conjunctival sac; three harboured multiple colonies with different PFGE patterns, and two manifested multiple colonies with identical PFGE patterns. S. epidermidis isolated from the conjunctival sac of the same subjects over a 6-month period exhibited varying PFGE patterns. The data demonstrate the polyclonality of S. epidermidis on the healthy ocular surface.

  3. Contact lens-related dry eye and ocular surface changes with mapping technique in long-term soft silicone hydrogel contact lens wearers.

    PubMed

    Sengor, Tomris; Aydin Kurna, Sevda; Ozbay, Nurver; Ertek, Semahat; Aki, Suat; Altun, Ahmet

    2012-01-01

    To evaluate ocular surface changes in long-term silicone hydrogel contact lens wearers. Thirty patients were included in this study. Twenty patients (40 eyes) using contact lenses constituted group 1 and 10 (20 eyes) volunteers constituted group 2. The duration of average contact lens usage was 7.74 ± 3.3 years. Ocular surface was evaluated by surface staining, tear film break-up time (TBUT), Schirmer I test, and conjunctival impression cytology with color-coded mapping technique and by the Ocular Surface Disease Index (OSDI). The mean break-up time was lower and staining scores were higher in group 1 (p<0.001) but Schirmer values were not significantly different from group 2 (p>0.05). The mean OSDI score was 34.59 ± 11.93 to 19.28 ± 6.7 in group 1 and 2. Increased metaplastic predominant changes of grade II and III were observed in the interpalpebral and perilimbal areas in group 1. Significant correlations were observed in TBUT, cornea staining, and grade II to grade III metaplasia ratios between duration of the lens usage and contact lens wear time in a day. Silicone hydrogel lenses produce significant changes on tear film and impression cytology of the ocular surface in long-term use.

  4. The contribution of accommodation and the ocular surface to the microfluctuations of wavefront aberrations of the eye.

    PubMed

    Zhu, Mingxia; Collins, Michael J; Iskander, D Robert

    2006-09-01

    We have used videokeratoscopy and wavefront sensing to investigate the contribution of the ocular surface and the effect of stimulus vergence on the microfluctuations of the wavefront aberrations of the eye. The fluctuations of the wavefront aberrations were quantified by their variations around the mean and by using power spectrum analysis. Integrated power was determined in two regions: 0.1-0.7 Hz (low frequencies) and 0.8-1.8 Hz (high frequencies). Changes in the ocular surface topography were measured using high-speed videokeratoscopy and variations in the ocular wavefront aberrations were measured with a wavefront sensor. The microfluctuations of wavefront aberrations of the ocular surface were found to be considerably smaller than the microfluctuations of the wavefront aberrations of the total eye. The fluctuations in defocus while viewing a closer target at 2 or 4 D were found to be significantly greater than fluctuations in defocus when viewing a far target. This increase in defocus fluctuations (p < or = 0.001) occurred in both the low- and high-frequency regions of the power spectra.

  5. A novel small molecule ameliorates ocular neovascularisation and synergises with anti-VEGF therapy.

    PubMed

    Sulaiman, Rania S; Merrigan, Stephanie; Quigley, Judith; Qi, Xiaoping; Lee, Bit; Boulton, Michael E; Kennedy, Breandán; Seo, Seung-Yong; Corson, Timothy W

    2016-05-05

    Ocular neovascularisation underlies blinding eye diseases such as retinopathy of prematurity, proliferative diabetic retinopathy, and wet age-related macular degeneration. These diseases cause irreversible vision loss, and provide a significant health and economic burden. Biologics targeting vascular endothelial growth factor (VEGF) are the major approach for treatment. However, up to 30% of patients are non-responsive to these drugs and they are associated with ocular and systemic side effects. Therefore, there is a need for small molecule ocular angiogenesis inhibitors to complement existing therapies. We examined the safety and therapeutic potential of SH-11037, a synthetic derivative of the antiangiogenic homoisoflavonoid cremastranone, in models of ocular neovascularisation. SH-11037 dose-dependently suppressed angiogenesis in the choroidal sprouting assay ex vivo and inhibited ocular developmental angiogenesis in zebrafish larvae. Additionally, intravitreal SH-11037 (1 μM) significantly reduced choroidal neovascularisation (CNV) lesion volume in the laser-induced CNV mouse model, comparable to an anti-VEGF antibody. Moreover, SH-11037 synergised with anti-VEGF treatments in vitro and in vivo. Up to 100 μM SH-11037 was not associated with signs of ocular toxicity and did not interfere with retinal function or pre-existing retinal vasculature. SH-11037 is thus a safe and effective treatment for murine ocular neovascularisation, worthy of further mechanistic and pharmacokinetic evaluation.

  6. Ocular hazards of the colors used during the festival-of-colors (Holi) in India--malachite green toxicity.

    PubMed

    Velpandian, T; Saha, K; Ravi, A K; Kumari, S S; Biswas, N R; Ghose, S

    2007-01-10

    The objective of this study was to evaluate the nature of the colors used and their toxicity to the eye upon exposure to them during celebration of Holi (our festival-of-colors). Color powders and formulations were procured at random in and around Delhi during the festival. The green/bluish-green colors reported with the higher incidence of ocular toxicity were subjected for further evaluation. Eyewash fluid collected from the patients exposed to the colors was also subjected for analysis. This study was further extended to evaluate the corneal penetration of malachite green using goat cornea in perfusion chamber. In 16/18 color samples collected, malachite green or 4-[(4-dimethylaminophenyl)-phenyl-methyl]-N,N-dimethyl-aniline was detected at different concentrations. In the eyewash fluid of four patients, HPLC estimation confirmed the presence of malachite green at concentrations of 1.3, 0.18, 3.5 and 5.4 microg in 250 ml which was responsible for its reported toxicity. The in vitrotrans-corneal penetration studies did not show any detectable amount of malachite green in effluent fluid-in vitro tissue retention studies revealed that increasing the contact time increases tissue concentration. After 2 min of exposure, the tissue concentration was significantly higher. To conclude, malachite green was extensively used in our festival of Holi and has caused severe ocular irritation with epithelial defect upon exposure, though it did not penetrate through the cornea-further in vitro and in vivo studies are required on colors used in Holi.

  7. Penetration of mucoadhesive chitosan-dextran sulfate nanoparticles into the porcine cornea.

    PubMed

    Chaiyasan, Wanachat; Praputbut, Sakonwun; Kompella, Uday B; Srinivas, Sangly P; Tiyaboonchai, Waree

    2017-01-01

    Topical application of drugs to the eyes suffers from poor bioavailability at the ocular surface and in the anterior chamber. This is due to rapid clearance of the drug because of tear secretion and outflow. This study has investigated mucoadhesive and penetration characteristics of chitosan-dextran sulfate nanoparticles (CDNs), prepared by polyelectrolyte complexation technique, following topical administration to the ocular surface. Topical FITC-labeled CDNs (FCDNs; mean size of 400nm and a surface charge of +48mV) were retained on the porcine ocular surface for more than 4h. Topical FCDNs were partially endocytosed into porcine corneal epithelial cells via a clathrin-dependent pathway. After 6h of topical FCDNs, particles accumulated in the corneal epithelium but not found in the corneal stroma. When epithelium was removed, FCDNs penetrated the stroma. Thus, CDNs are potentially useful for drug/gene delivery to the ocular surface and to stroma when epithelium is damaged. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. The Effects of Increasing Ocular Surface Stimulation on Blinking and Tear Secretion

    PubMed Central

    Wu, Ziwei; Begley, Carolyn G.; Port, Nicholas; Bradley, Arthur; Braun, Richard; King-Smith, Ewen

    2015-01-01

    Purpose. To investigate the effect of varying levels of ocular surface stimulation on the timing and amplitude of the blink and tear secretion. Methods. Following instillation of fluorescein dye, increasing levels of air flow were directed toward the central corneas of 10 healthy subjects. Interblink interval (IBI), tear meniscus height (TMH), and fluorescence intensity were measured simultaneously. Because blinking can obscure changes in TMH, we developed novel measures of tear secretion by calculating tear meniscus fluorescein concentration (TMFC) from intensity using a mathematical model. The change of TMH and TMFC over trials and the slope of the TMFC within each IBI (IBI-TTR) were further calculated. Results. The mean IBI was decreased by 8.08 ± 8.54 seconds from baseline to maximum air stimulation. The TMH increase was highly variable (0.41 ± 0.39 mm) among subjects, compared to the fluorescence tear turnover metrics: decrease in TMFC of 2.84 ± 0.98 natural logarithm or ln(%) and IBI-TTR of 0.065 ± 0.032 ln(%)/sec. Ocular surface stimulation was highly correlated with the TMFC and IBI-TTR, but less so with TMH (Pearson's r = 0.71, 0.69, and 0.40, P < 0.01, respectively). Blinking and tearing were significantly correlated with each other (Pearson's r = 0.56, P < 0.01), but tearing lagged behind by an average of 6.54 ± 4.07 seconds. Conclusions. Blinking and tearing share a common origin with sensory stimulation at the ocular surface. Both showed a dose–response increase with surface stimulation and were correlated with each other. These methods can potentially be used to understand alterations in ocular surface sensory function and associated protective responses in dry eye and other disorders of the ocular surface. PMID:26132780

  9. The Effects of Increasing Ocular Surface Stimulation on Blinking and Tear Secretion.

    PubMed

    Wu, Ziwei; Begley, Carolyn G; Port, Nicholas; Bradley, Arthur; Braun, Richard; King-Smith, Ewen

    2015-07-01

    To investigate the effect of varying levels of ocular surface stimulation on the timing and amplitude of the blink and tear secretion. Following instillation of fluorescein dye, increasing levels of air flow were directed toward the central corneas of 10 healthy subjects. Interblink interval (IBI), tear meniscus height (TMH), and fluorescence intensity were measured simultaneously. Because blinking can obscure changes in TMH, we developed novel measures of tear secretion by calculating tear meniscus fluorescein concentration (TMFC) from intensity using a mathematical model. The change of TMH and TMFC over trials and the slope of the TMFC within each IBI (IBI-TTR) were further calculated. The mean IBI was decreased by 8.08 ± 8.54 seconds from baseline to maximum air stimulation. The TMH increase was highly variable (0.41 ± 0.39 mm) among subjects, compared to the fluorescence tear turnover metrics: decrease in TMFC of 2.84 ± 0.98 natural logarithm or ln(%) and IBI-TTR of 0.065 ± 0.032 ln(%)/sec. Ocular surface stimulation was highly correlated with the TMFC and IBI-TTR, but less so with TMH (Pearson's r = 0.71, 0.69, and 0.40, P < 0.01, respectively). Blinking and tearing were significantly correlated with each other (Pearson's r = 0.56, P < 0.01), but tearing lagged behind by an average of 6.54 ± 4.07 seconds. Blinking and tearing share a common origin with sensory stimulation at the ocular surface. Both showed a dose-response increase with surface stimulation and were correlated with each other. These methods can potentially be used to understand alterations in ocular surface sensory function and associated protective responses in dry eye and other disorders of the ocular surface.

  10. A nanomedicine to treat ocular surface inflammation: performance on an experimental dry eye murine model.

    PubMed

    Contreras-Ruiz, L; Zorzi, G K; Hileeto, D; López-García, A; Calonge, M; Seijo, B; Sánchez, A; Diebold, Y

    2013-05-01

    MUC5AC is a glycoprotein with gel-forming properties, whose altered expression has been implicated in the pathogenesis of dry eye disease. The aim of our study was to achieve an efficient in vivo transfection of MUC5AC, restore its normal levels in an inflamed ocular surface and determine whether restored MUC5AC levels improve ocular surface inflammation. Cationized gelatin-based nanoparticles (NPs) loaded with a plasmid coding a modified MUC5AC protein (pMUC5AC) were instilled in healthy and experimental dry eye (EDE) mice. MUC5AC expression, clinical signs, corneal fluorescein staining and tear production were evaluated. Ocular specimens were processed for histopathologic evaluation, including goblet cell count and CD4 immunostaining. Neither ocular discomfort nor irritation was observed in vivo after NP treatment. Expression of modified MUC5AC was significantly higher in ocular surface tissue of pMUC5AC-NP-treated animals than that of controls. In healthy mice, pMUC5AC-NPs had no effect on fluorescein staining or tear production. In EDE mice, both parameters significantly improved after pMUC5AC-NP treatment. Anterior eye segment of treated mice showed normal architecture and morphology with lack of remarkable inflammatory changes, and a decrease in CD4+ T-cell infiltration. Thus, pMUC5AC-NPs were well tolerated and able to induce the expression of modified MUC5A in ocular surface tissue, leading to reduction of the inflammation and, consequently improving the associated clinical parameters, such as tear production and fluorescein staining. These results identify a potential application of pMUC5AC-NPs as a new therapeutic modality for the treatment of dry eye disease.

  11. The TFOS International Workshop on Contact Lens Discomfort: Report of the Subcommittee on Neurobiology

    PubMed Central

    Stapleton, Fiona; Marfurt, Carl; Golebiowski, Blanka; Rosenblatt, Mark; Bereiter, David; Begley, Carolyn; Dartt, Darlene; Gallar, Juana; Belmonte, Carlos; Hamrah, Pedram; Willcox, Mark

    2013-01-01

    This report characterizes the neurobiology of the ocular surface and highlights relevant mechanisms that may underpin contact lens–related discomfort. While there is limited evidence for the mechanisms involved in contact lens–related discomfort, neurobiological mechanisms in dry eye disease, the inflammatory pathway, the effect of hyperosmolarity on ocular surface nociceptors, and subsequent sensory processing of ocular pain and discomfort have been at least partly elucidated and are presented herein to provide insight in this new arena. The stimulus to the ocular surface from a contact lens is likely to be complex and multifactorial, including components of osmolarity, solution effects, desiccation, thermal effects, inflammation, friction, and mechanical stimulation. Sensory input will arise from stimulation of the lid margin, palpebral and bulbar conjunctiva, and the cornea. PMID:24058137

  12. Isolation of the ocular surface to treat dysfunctional tear syndrome associated with computer use.

    PubMed

    Yee, Richard W; Sperling, Harry G; Kattek, Ashballa; Paukert, Martin T; Dawson, Kevin; Garcia, Marcie; Hilsenbeck, Susan

    2007-10-01

    Dysfunctional tear syndrome (DTS) associated with computer use is characterized by mild irritation, itching, redness, and intermittent tearing after extended staring. It frequently involves foreign body or sandy sensation, blurring of vision, and fatigue, worsening especially at the end of the day. We undertook a study to determine the effectiveness of periocular isolation using microenvironment glasses (MEGS) alone and in combination with artificial tears in alleviating the symptoms and signs of dry eye related to computer use. At the same time, we evaluated the relative ability of a battery of clinical tests for dry eye to distinguish dry eyes from normal eyes in heavy computer users. Forty adult subjects who used computers 3 hours or more per day were divided into dry eye sufferers and controls based on their scores on the Ocular Surface Disease Index (OSDI). Baseline scores were recorded and ocular surface assessments were made. On four subsequent visits, the subjects played a computer game for 30 minutes in a controlled environment, during which one of four treatment conditions were applied, in random order, to each subject: 1) no treatment, 2) artificial tears, 3) MEGS, and 4) artificial tears combined with MEGS. Immediately after each session, subjects were tested on: a subjective comfort questionnaire, tear breakup time (TBUT), fluorescein staining, lissamine green staining, and conjunctival injection. In this study, a significant correlation was found between cumulative lifetime computer use and ocular surface disorder, as measured by the standardized OSDI index. The experimental and control subjects were significantly different (P<0.05) in the meibomian gland assessment and TBUT; they were consistently different in fluorescein and lissamine green staining, but with P>0.05. Isolation of the ocular surface alone produced significant improvements in comfort scores and TBUT and a consistent trend of improvement in fluorescein staining and lissamine green staining. Isolation plus tears produced a significant improvement in lissamine green staining. The subjective comfort inventory and the TBUT test were most effective in distinguishing between the treatments used. Computer users with ocular surface complaints should have a detailed ocular surface examination and, if symptomatic, they can be effectively treated with isolation of the ocular surface, artificial tears therapy, and effective environmental manipulations.

  13. A Review of Ocular Graft-Versus-Host Disease.

    PubMed

    Munir, Saleha Z; Aylward, James

    2017-05-01

    : Graft-versus-host disease (GVHD) is a major complication that occurs following allogeneic hematopoietic stem cell transplantation, which is a potential curative therapy used in a variety of malignant or benign hematological diseases. Graft-versus-host disease primarily occurs in many organs, but most notably in the skin, lungs, gastrointestinal tract, liver, eyes, mucosa, and musculoskeletal system. Ocular manifestations of GVHD may precede other systemic GVHD findings, and it may be a poor prognosis for mortality. While all parts of the eye may be affected, ocular GVHD occurs primarily in the ocular surface. Dry eye disease or keratoconjunctivitis sicca is the most common presenting manifestation of chronic ocular GVHD. Dry eye disease in ocular GVHD is a multifactorial process, which involves destruction and fibrosis of lacrimal glands and conjunctiva, leading to tear film deficiency and instability. Depending on the severity of ocular involvement and response to treatment, ocular GVHD may cause decreased quality of life. Management of GVHD begins with prevention by understanding risk factors and by implementing prophylactic treatment after allogeneic hematopoietic stem cell transplantation. A multidisciplinary approach to the prevention and treatment of GVHD is important, and there are currently no preventive therapies available for ocular GVHD. Once diagnosed, ocular GVHD treatment strategies target ocular surface lubrication and support, tear film stabilization, inflammation reduction, and surgical intervention. The goal of this review is to define ocular GVHD and its categorical manifestations, as well as to describe the importance of comprehensive assessment, diagnosis, and ophthalmologic treatment and management of ocular GVHD with a multidisciplinary approach.

  14. Biological Applications and Effects of Optical Masers

    DTIC Science & Technology

    1988-02-19

    LANDOLT RING SYSTEM 8-10 8. EARLY STUDIES ON SOLAR RADIATION AS A RETINAL HAZARD 10-15 9. RETINAL LIGHT TOXICITY AS A FUNCTION OF WAVE’.ENGTH 15-16 10...providing a simulated solor spectrum and 10 nm bandwidths throughout the near ultraviolet, visible and near infrared spectrum. This early ocular...do not present an ocular hazard at the levels used by the MILES prototype system or in fiber optic communication systems . By 1966 enough burn

  15. Antibacterial activity of dilute povidone-iodine solutions used for ocular surface disinfection in dogs.

    PubMed

    Roberts, S M; Severin, G A; Lavach, J D

    1986-06-01

    Bacterial cultures of specimens from healthy canine eyelids and ocular surfaces were found to demonstrate bacterial growth in 69.7% (53/76) of the eyes sampled. Organisms most commonly isolated included: Staphylococcus aureus, alpha-hemolytic Streptococcus sp, S epidermidis, and Escherichia coli. Evaluation of dilute povidone-iodine solutions for effectiveness as ocular surface disinfectants was conducted. Bacterial growth initially detected in 32 of 46 eyes was not detected after disinfection with a 2-minute scrub and 2-minute soaking procedure, using 1:2, 1:10, or 1:50 dilutions of a povidone-iodine solution that contained 1% available iodine. The eyelid and ocular surfaces of 16 eyes were disinfected with 1:100 povidone-iodine solution. Bacterial growth initially present in 10 of 16 eyes was present in 1 eye after disinfection and consisted of a single colony of E coli. After eyes were disinfected with 1:10, 1:50, or 1:100 povidone-iodine solutions, there was no evidence of corneal epithelial edema or sloughing. In 15 eyes subjected to disinfection with the 1:2 dilution, one instance of epithelial corneal edema was noticed. A 1:50 dilution of povidone-iodine is recommended as an ocular surface disinfectant for use in presurgical situations.

  16. Advantages of Efficacy and Safety of Fixed-Dose Tafluprost/Timolol Combination Over Fixed-Dose Latanoprost/Timolol Combination.

    PubMed

    Fuwa, Masahiro; Ueda, Kenji; Akaishi, Takahiro; Yamashita, Naoko; Kirihara, Tomoko; Shimazaki, Atsushi; Mano, Hidetoshi; Kawazu, Kouichi

    2016-01-01

    To compare the safety and efficacy of fixed-dose tafluprost/timolol combination (Taf/T-FDC) with those of fixed-dose latanoprost/timolol combination (Lat/T-FDC) by measuring the intraocular pressure (IOP)-lowering effect, ocular pharmacokinetics, and ocular surface toxicity. The IOP-lowering effect of Taf/T-FDC and Lat/T-FDC in ocular normotensive monkeys was evaluated at 4 and 8 h after instillation in study A, at 12, 14, 16, and 18 h after instillation in study B, and at 24, 26, 28, and 30 h after instillation in study C. Drug penetration into the eye was evaluated by measuring the concentrations of timolol, tafluprost acid (active metabolic form of tafluprost), and latanoprost acid (active metabolic form of latanoprost) using liquid chromatography coupled with tandem mass spectrometry after single instillation of Taf/T-FDC or Lat/T-FDC to Sprague Dawley rats. Cytotoxicity following 1-30 min exposure of SV40-transformed human corneal epithelial cells to Taf/T-FDC or Lat/T-FDC was analyzed using 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium assays. Undiluted and 10-fold diluted solutions of each FDC were evaluated. The IOP-lowering effect of Taf/T-FDC was almost equivalent to that of Lat/T-FDC at 4-8 h after instillation. The peak IOP reduction of Taf/T-FDC and Lat/T-FDC was observed at 8 h after instillation, and there is no difference between the two. The difference between them was observed at 24-30 h after instillation, and Taf/T-FDC demonstrated a significantly greater IOP-lowering effect than Lat/T-FDC at 24-30 h after instillation. The IOP-lowering effect of Taf/T-FDC was sustained up to 30 h after instillation, while that of Lat/T-FDC had almost disappeared at 28 h after instillation. Timolol concentrations in aqueous humor after Taf/T-FDC instillation were higher than those after Lat/T-FDC instillation (Cmax, 3870 ng/mL vs 1330 ng/mL; AUCinf, 3970 ng·h/mL vs 1250 ng·h/mL). The concentrations of tafluprost acid and latanoprost acid in aqueous humor after instillation of Taf/T-FDC and Lat/T-FDC, respectively, were similar to those after instillation of mono-preparations of tafluprost and latanoprost, respectively. The cytotoxic effect of Taf/T-FDC to the human corneal epithelial cells was significantly lower than that of Lat/T-FDC at all evaluated time points in both undiluted and 10-fold diluted FDCs. Taf/T-FDC provides increased IOP-lowering effect duration and lower potential ocular surface toxicity than Lat/T-FDC.

  17. Advantages of Efficacy and Safety of Fixed-Dose Tafluprost/Timolol Combination Over Fixed-Dose Latanoprost/Timolol Combination

    PubMed Central

    Fuwa, Masahiro; Ueda, Kenji; Akaishi, Takahiro; Yamashita, Naoko; Kirihara, Tomoko; Shimazaki, Atsushi; Mano, Hidetoshi; Kawazu, Kouichi

    2016-01-01

    Purpose To compare the safety and efficacy of fixed-dose tafluprost/timolol combination (Taf/T-FDC) with those of fixed-dose latanoprost/timolol combination (Lat/T-FDC) by measuring the intraocular pressure (IOP)-lowering effect, ocular pharmacokinetics, and ocular surface toxicity. Methods The IOP-lowering effect of Taf/T-FDC and Lat/T-FDC in ocular normotensive monkeys was evaluated at 4 and 8 h after instillation in study A, at 12, 14, 16, and 18 h after instillation in study B, and at 24, 26, 28, and 30 h after instillation in study C. Drug penetration into the eye was evaluated by measuring the concentrations of timolol, tafluprost acid (active metabolic form of tafluprost), and latanoprost acid (active metabolic form of latanoprost) using liquid chromatography coupled with tandem mass spectrometry after single instillation of Taf/T-FDC or Lat/T-FDC to Sprague Dawley rats. Cytotoxicity following 1–30 min exposure of SV40-transformed human corneal epithelial cells to Taf/T-FDC or Lat/T-FDC was analyzed using 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium assays. Undiluted and 10-fold diluted solutions of each FDC were evaluated. Results The IOP-lowering effect of Taf/T-FDC was almost equivalent to that of Lat/T-FDC at 4–8 h after instillation. The peak IOP reduction of Taf/T-FDC and Lat/T-FDC was observed at 8 h after instillation, and there is no difference between the two. The difference between them was observed at 24–30 h after instillation, and Taf/T-FDC demonstrated a significantly greater IOP-lowering effect than Lat/T-FDC at 24–30 h after instillation. The IOP-lowering effect of Taf/T-FDC was sustained up to 30 h after instillation, while that of Lat/T-FDC had almost disappeared at 28 h after instillation. Timolol concentrations in aqueous humor after Taf/T-FDC instillation were higher than those after Lat/T-FDC instillation (Cmax, 3870 ng/mL vs 1330 ng/mL; AUCinf, 3970 ng·h/mL vs 1250 ng·h/mL). The concentrations of tafluprost acid and latanoprost acid in aqueous humor after instillation of Taf/T-FDC and Lat/T-FDC, respectively, were similar to those after instillation of mono-preparations of tafluprost and latanoprost, respectively. The cytotoxic effect of Taf/T-FDC to the human corneal epithelial cells was significantly lower than that of Lat/T-FDC at all evaluated time points in both undiluted and 10-fold diluted FDCs. Conclusion Taf/T-FDC provides increased IOP-lowering effect duration and lower potential ocular surface toxicity than Lat/T-FDC. PMID:27383260

  18. Therapeutic inhibitors for the treatment of dry eye syndrome.

    PubMed

    Rodríguez-Pomar, Candela; Pintor, Jesus; Colligris, Basilio; Carracedo, Gonzalo

    2017-12-01

    Dry eye disease (DED), defined as a multifactorial disease of tears and ocular surface, results in symptoms of discomfort, ocular irritation, visual disturbance and tear film instability. This syndrome is accompanied of ocular surface inflammation and it is produced by a deficient activity of the lacrimal functional unit. In addition, it is associated with systemic autoimmune diseases such as Sjögren´s Syndrome, rheumatoid arthritis, systemic lupus erythematosus and some drug administration. The treatment of dry eye disease is based on the typical signs and symptoms of dry eye, which are associated with hyperosmolarity, ocular surface inflammation, discomfort, visual disturbance, and tear film instability. Areas covered: This review is focused on synthetic drugs currently used in clinical practice, from phase III development onwards to treat the ocular surface signs and symptoms of dry eye disease. Expert opinion: The multifactorial disease and the lack of correlation between signs and symptoms imply that not all the pharmacological approaches will be successful for dry eye. The correct design of the clinical trials, with appropriate endpoints, and the type of dry eye under study are complicated but mandatory. The anti-inflammatory and secretagogues drugs are both the main compounds to currently treat the dry eye disease.

  19. Down-regulation of Pax6 is associated with abnormal differentiation of corneal epithelial cells in severe ocular surface diseases

    PubMed Central

    Li, W; Chen, Y-T; Hayashida, Y; Blanco, G; Kheirkah, A; He, H; Chen, S-Y; Liu, C-Y; Tseng, SCG

    2010-01-01

    Pax6 is the universal master control gene for eye morphogenesis. Other than retina and lens, Pax6 also expressed in the ocular surface epithelium from early gestation until the postnatal stage, in which little is known about the function of Pax6. In this study, corneal pannus tissues from patients with ocular surface diseases such as Stevens–Johnson syndrome (SJS), chemical burn, aniridia and recurrent pterygium were investigated. Our results showed that normal ocular surface epithelial cells expressed Pax6. However, corneal pannus epithelial cells from the above patients showed a decline or absence of Pax6 expression, accompanied by a decline or absence of K12 keratin but an increase of K10 keratin and filaggrin expression. Pannus basal epithelial cells maintained nuclear p63 expression and showed activated proliferation, evidenced by positive Ki67 and K16 keratin staining. On 3T3 fibroblast feeder layers, Pax6 immunostaining was negative in clones generated from epithelial cells harvested from corneal pannus from SJS or aniridia, but positive in those from the normal limbal epithelium; whereas western blots showed that some epithelial clones expanded from pannus retained Pax6 expression. Transient transfection of an adenoviral vector carrying EGFP–Pax6 transgenes into these Pax6− clones increased both Pax6 and K12 keratin expression. These results indicate that Pax6 helps to maintain the normal corneal epithelial phenotype postnatally, and that down-regulation of Pax6 is associated with abnormal epidermal differentiation in severe ocular surface diseases. Reintroduction of activation of the Pax6 gene might be useful in treating squamous metaplasia of the ocular surface epithelium. PMID:18027901

  20. Ocular Surface Symptoms in Veterans Returning From Operation Iraqi Freedom and Operation Enduring Freedom

    PubMed Central

    Modi, Yasha S.; Qurban, Qirat; Zlotcavitch, Leonid; Echeverri, Roberto J.; Feuer, William; Florez, Hermes; Galor, Anat

    2014-01-01

    Purpose. To correlate situational exposures and psychiatric disease with self-reported ocular surface symptoms in a younger veteran population involved in Operation Iraqi Freedom and Operation Enduring Freedom (OIF/OEF). Methods. Cross-sectional study of all veterans evaluated in the OIF/OEF clinic between December 2012 and April 2013 who completed the dry eye questionnaire and screening evaluations for environmental exposures, posttraumatic stress disorder (PTSD), and depression. The main outcome measures were the influence of environmental exposure and psychiatric disease on ocular surface symptoms. Results. Of 115 participants, the average age was 33 years. While overseas, exposure to incinerated waste (odds ratio [OR] 2.67, 95% confidence interval [CI] 1.23–5.81, P = 0.02) and PTSD (OR 2.68, 95% CI 1.23–5.85, P = 0.02) were associated with self-reported ocular surface symptoms. On return to the United States, older age (OR per decade 2.66, 95% CI 1.65–4.31, P = 0.04) was associated with persistent symptoms and incinerated waste was associated with resolution of symptoms (OR 0.25, 95% CI 0.07–0.90, P = 0.04). When evaluating symptom severity, 26% of the responders complained of severe ocular surface symptoms, with PTSD (OR 3.10, 95% CI 1.22–7.88, P = 0.02) and depression (OR 4.28, 95% CI 1.71–10.68, P = 0.002) being significant risk factors for their presence. Conclusions. PTSD was significantly associated with ocular surface symptoms both abroad and on return to the United States, whereas air pollution in the form of incinerated waste, was correlated with reversible symptoms. PMID:24408975

  1. Ocular toxicity in BRAF mutant cutaneous melanoma patients treated with vemurafenib.

    PubMed

    Choe, Christina H; McArthur, Grant A; Caro, Ivor; Kempen, John H; Amaravadi, Ravi K

    2014-10-01

    To determine the frequency of ocular adverse effects associated with vemurafenib (PLX4032) treatment for metastatic cutaneous melanoma. Retrospective review of the clinical study reports from the clinical pharmacology, phase 1, phase 2, and phase 3 trials of vemurafenib. The vemurafenib clinical trials were a multicenter series involving adult patients with histologically confirmed, BRAF(V600) mutation-positive, unresectable, stage IIIC or IV melanoma. A total of 855 patients were enrolled in the trials: 568 patients were treated with vemurafenib and 287 patients were treated with dacarbazine. Among the 568 patients treated with vemurafenib, ocular adverse effects developed in 22% (95% confidence interval [CI], 18.5-25.6). The most common ocular diagnosis was uveitis (4.0%; 95% CI, 2.6-6.0), followed by conjunctivitis (2.8%; 95% CI, 1.6-4.5) and dry eyes (2.0%; 95% CI, 1.1-3.7). All were successfully managed while vemurafenib therapy was continued. Ocular adverse events and symptoms may be seen in more than one-fifth of patients being treated with vemurafenib. However, vemurafenib can be continued while the ocular symptoms are being managed. The pathogenesis of ocular symptoms in this patient population is unclear; additional studies are necessary. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Clinical evaluation of accommodation and ocular surface stability relavant to visual asthenopia with 3D displays

    PubMed Central

    2014-01-01

    Background To validate the association between accommodation and visual asthenopia by measuring objective accommodative amplitude with the Optical Quality Analysis System (OQAS®, Visiometrics, Terrassa, Spain), and to investigate associations among accommodation, ocular surface instability, and visual asthenopia while viewing 3D displays. Methods Fifteen normal adults without any ocular disease or surgical history watched the same 3D and 2D displays for 30 minutes. Accommodative ability, ocular protection index (OPI), and total ocular symptom scores were evaluated before and after viewing the 3D and 2D displays. Accommodative ability was evaluated by the near point of accommodation (NPA) and OQAS to ensure reliability. The OPI was calculated by dividing the tear breakup time (TBUT) by the interblink interval (IBI). The changes in accommodative ability, OPI, and total ocular symptom scores after viewing 3D and 2D displays were evaluated. Results Accommodative ability evaluated by NPA and OQAS, OPI, and total ocular symptom scores changed significantly after 3D viewing (p = 0.005, 0.003, 0.006, and 0.003, respectively), but yielded no difference after 2D viewing. The objective measurement by OQAS verified the decrease of accommodative ability while viewing 3D displays. The change of NPA, OPI, and total ocular symptom scores after 3D viewing had a significant correlation (p < 0.05), implying direct associations among these factors. Conclusions The decrease of accommodative ability after 3D viewing was validated by both subjective and objective methods in our study. Further, the deterioration of accommodative ability and ocular surface stability may be causative factors of visual asthenopia in individuals viewing 3D displays. PMID:24612686

  3. Ocular Drug Delivery Barriers-Role of Nanocarriers in the Treatment of Anterior Segment Ocular Diseases.

    PubMed

    Bachu, Rinda Devi; Chowdhury, Pallabitha; Al-Saedi, Zahraa H F; Karla, Pradeep K; Boddu, Sai H S

    2018-02-27

    Ocular drug delivery is challenging due to the presence of anatomical and physiological barriers. These barriers can affect drug entry into the eye following multiple routes of administration (e.g., topical, systemic, and injectable). Topical administration in the form of eye drops is preferred for treating anterior segment diseases, as it is convenient and provides local delivery of drugs. Major concerns with topical delivery include poor drug absorption and low bioavailability. To improve the bioavailability of topically administered drugs, novel drug delivery systems are being investigated. Nanocarrier delivery systems demonstrate enhanced drug permeation and prolonged drug release. This review provides an overview of ocular barriers to anterior segment delivery, along with ways to overcome these barriers using nanocarrier systems. The disposition of nanocarriers following topical administration, their safety, toxicity and clinical trials involving nanocarrier systems are also discussed.

  4. Ocular Drug Delivery Barriers—Role of Nanocarriers in the Treatment of Anterior Segment Ocular Diseases

    PubMed Central

    Bachu, Rinda Devi; Chowdhury, Pallabitha; Al-Saedi, Zahraa H. F.; Karla, Pradeep K.; Boddu, Sai H. S.

    2018-01-01

    Ocular drug delivery is challenging due to the presence of anatomical and physiological barriers. These barriers can affect drug entry into the eye following multiple routes of administration (e.g., topical, systemic, and injectable). Topical administration in the form of eye drops is preferred for treating anterior segment diseases, as it is convenient and provides local delivery of drugs. Major concerns with topical delivery include poor drug absorption and low bioavailability. To improve the bioavailability of topically administered drugs, novel drug delivery systems are being investigated. Nanocarrier delivery systems demonstrate enhanced drug permeation and prolonged drug release. This review provides an overview of ocular barriers to anterior segment delivery, along with ways to overcome these barriers using nanocarrier systems. The disposition of nanocarriers following topical administration, their safety, toxicity and clinical trials involving nanocarrier systems are also discussed. PMID:29495528

  5. Aqueous humor tyrosinase activity is indicative of iris melanocyte toxicity.

    PubMed

    Mahanty, Sarmistha; Kawali, Ankush A; Dakappa, Shruthi Shirur; Mahendradas, Padmamalini; Kurian, Mathew; Kharbanda, Varun; Shetty, Rohit; Setty, Subba Rao Gangi

    2017-09-01

    Antibiotics such as fluoroquinolones (FQLs) are commonly used to treat ocular infections but are also known to cause dermal melanocyte toxicity. The release of dispersed pigments from the iris into the aqueous humor has been considered a possible ocular side effect of the systemic administration of FQLs such as Moxifloxacin, and this condition is known as bilateral acute iris transillumination (BAIT). Bilateral acute depigmentation of iris (BADI) is a similar condition, with iris pigment released into the aqueous, but it has not been reported as a side effect of FQL. Iris pigments are synthesized by the melanogenic enzyme tyrosinase (TYR) and can be detected but not quantified by using slit-lamp biomicroscopy. The correlation between dispersed pigments in the aqueous and the extent of melanocyte toxicity due to topical antibiotics in vivo is not well studied. Here, we aimed to study the effect of topical FQLs on iris tissue, the pigment release in the aqueous humor and the development of clinically evident iris atrophic changes. We evaluated this process by measuring the activity of TYR in the aqueous humor of 82 healthy eyes undergoing cataract surgery following topical application of FQLs such as Moxifloxacin (27 eyes, preservative-free) or Ciprofloxacin (29 eyes, with preservative) or the application of non-FQL Tobramycin (26 eyes, with preservative) as a control. In addition, the patients were questioned and examined for ocular side effects in pre- and post-operative periods. Our data showed a significantly higher mean TYR activity in the aqueous humor of Ciprofloxacin-treated eyes compared to Moxifloxacin- (preservative free, p < 0.0001) or Tobramycin-treated eyes (p < 0.0001), which indicated that few quinolones under certain conditions are toxic to the iris melanocytes. However, the reduced TYR activity in the aqueous of Moxifloxacin-treated eyes was possibly due to the presence of a higher drug concentration, which inhibits TYR activity. Consistently, immunoblotting analysis of the aqueous humor from both Ciprofloxacin- and Moxifloxacin-treated eyes showed the presence of soluble TYR enzyme, thus reflecting its toxicity to iris melanocytes and corresponding to its activity in the aqueous humor. Intriguingly, none of these patients developed any clinically appreciable ocular side effects characteristic of BAIT or BADI. Overall, our results suggest that topical antibiotics cause different levels of iris melanocyte toxicity, releasing dispersed pigments into the aqueous humor, which can be measured through TYR enzyme activity. Hence, we conclude that topical FQLs may cause subclinical toxicity to the iris melanocytes but may not be the sole cause of the development of BAIT or BADI. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. A Multidisciplinary Orbit-Sparing Treatment Approach That Includes Proton Therapy for Epithelial Tumors of the Orbit and Ocular Adnexa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holliday, Emma B.; Esmaeli, Bita; Pinckard, Jamie

    Purpose: Postoperative radiation is often indicated in the treatment of malignant epithelial tumors of the orbit and ocular adnexa. We present details of radiation technique and toxicity data after orbit-sparing surgery followed by adjuvant proton radiation therapy. Methods and Materials: Twenty patients underwent orbit-sparing surgery followed by proton therapy for newly diagnosed malignant epithelial tumors of the lacrimal gland (n=7), lacrimal sac/nasolacrimal duct (n=10), or eyelid (n=3). Tumor characteristics, treatment details, and visual outcomes were obtained from medical records. Acute and chronic toxicity were prospectively scored using Common Terminology Criteria for Adverse Events version 4.0. Results: The median radiation dosemore » was 60 Gy(RBE) (relative biological effectiveness; [range 50-70 Gy]); 11 patients received concurrent chemotherapy. Dose to ipsilateral anterior optic structures was reduced in 13 patients by having them gaze away from the target during treatment. At a median follow-up time of 27.1 months (range 2.6-77.2 months), no patient had experienced local recurrence; 1 had regional and 1 had distant recurrence. Three patients developed chronic grade 3 epiphora, and 3 developed grade 3 exposure keratopathy. Four patients experienced a decrease in visual acuity from baseline but maintained vision sufficient to perform all activities of daily living without difficulty. Patients with grade ≥3 chronic ocular toxicity had higher maximum dose to the ipsilateral cornea (median 46.3 Gy[RBE], range 36.6-52.7 Gy[RBE] vs median 37.4 Gy[RBE], range 9.0-47.3 Gy(RBE); P=.017). Conclusions: Orbit-sparing surgery for epithelial tumors of the orbit and ocular adnexa followed by proton therapy successfully achieved disease control and was well tolerated. No patient required orbital exenteration or enucleation. Chronic grade 3 toxicity was associated with high maximum dose to the cornea. An eye-deviation technique can be used to limit the maximum corneal dose to <35 Gy(RBE).« less

  7. Ocular Toxicity Secondary to Asclepias physocarpa: The Balloon Plant.

    PubMed

    Pina, Susana; Pedrosa, Catarina; Santos, Cristina; Feijóo, Bernardo; Pego, Peter; Vendrell, Cristina; Santos, Maria João; Prieto, Isabel

    2014-01-01

    We report a case of a 65-year-old woman with symptoms of blurred vision and ocular irritation a few hours after accidental contact of the right eye with Asclepias physocarpa milky latex. Observation showed a diffuse conjunctival hyperemia and stromal corneal edema with Descemet's membrane folds. Recovery was fast and apparently complete in less than one month. However, specular microscopy at 6-months follow-up showed an abnormal endothelial morphology as sequelae, suggesting this condition is not as innocuous as it has been suggested.

  8. Requirement of Smad4 from Ocular Surface Ectoderm for Retinal Development.

    PubMed

    Li, Jing; Wang, Shusheng; Anderson, Chastain; Zhao, Fangkun; Qin, Yu; Wu, Di; Wu, Xinwei; Liu, Jia; He, Xuefei; Zhao, Jiangyue; Zhang, Jinsong

    2016-01-01

    Microphthalmia is characterized by abnormally small eyes and usually retinal dysplasia, accounting for up to 11% of the blindness in children. Right now there is no effective treatment for the disease, and the underlying mechanisms, especially how retinal dysplasia develops from microphthalmia and whether it depends on the signals from lens ectoderm are still unclear. Mutations in genes of the TGF-β superfamily have been noted in patients with microphthalmia. Using conditional knockout mice, here we address the question that whether ocular surface ectoderm-derived Smad4 modulates retinal development. We found that loss of Smad4 specifically on surface lens ectoderm leads to microphthalmia and dysplasia of retina. Retinal dysplasia in the knockout mice is caused by the delayed or failed differentiation and apoptosis of retinal cells. Microarray analyses revealed that members of Hedgehog and Wnt signaling pathways are affected in the knockout retinas, suggesting that ocular surface ectoderm-derived Smad4 can regulate Hedgehog and Wnt signaling in the retina. Our studies suggest that defective of ocular surface ectoderm may affect retinal development.

  9. Requirement of Smad4 from Ocular Surface Ectoderm for Retinal Development

    PubMed Central

    Li, Jing; Wang, Shusheng; Anderson, Chastain; Zhao, Fangkun; Qin, Yu; Wu, Di; Wu, Xinwei; Liu, Jia; He, Xuefei; Zhao, Jiangyue; Zhang, Jinsong

    2016-01-01

    Microphthalmia is characterized by abnormally small eyes and usually retinal dysplasia, accounting for up to 11% of the blindness in children. Right now there is no effective treatment for the disease, and the underlying mechanisms, especially how retinal dysplasia develops from microphthalmia and whether it depends on the signals from lens ectoderm are still unclear. Mutations in genes of the TGF-β superfamily have been noted in patients with microphthalmia. Using conditional knockout mice, here we address the question that whether ocular surface ectoderm-derived Smad4 modulates retinal development. We found that loss of Smad4 specifically on surface lens ectoderm leads to microphthalmia and dysplasia of retina. Retinal dysplasia in the knockout mice is caused by the delayed or failed differentiation and apoptosis of retinal cells. Microarray analyses revealed that members of Hedgehog and Wnt signaling pathways are affected in the knockout retinas, suggesting that ocular surface ectoderm-derived Smad4 can regulate Hedgehog and Wnt signaling in the retina. Our studies suggest that defective of ocular surface ectoderm may affect retinal development. PMID:27494603

  10. The Relationship Between High-Order Aberration and Anterior Ocular Biometry During Accommodation in Young Healthy Adults

    PubMed Central

    Ke, Bilian; Mao, Xinjie; Jiang, Hong; He, Jichang; Liu, Che; Li, Min; Yuan, Ying

    2017-01-01

    Purpose This study investigated the anterior ocular anatomic origin of high-order aberration (HOA) components using optical coherence tomography and a Shack-Hartmann wavefront sensor. Methods A customized system was built to simultaneously capture images of ocular wavefront aberrations and anterior ocular biometry. Relaxed, 2-diopter (D) and 4-D accommodative states were repeatedly measured in 30 young subjects. Custom software was used to correct optical distortions and measure biometric parameters from the images. Results The anterior ocular biometry changed during 2-D accommodation, in which central lens thickness, ciliary muscle thicknesses at 1 mm posterior to the scleral spur (CMT1), and the maximum value of ciliary muscle thickness increased significantly, whereas anterior chamber depth, CMT3, radius of anterior lens surface curvature (RAL), and radius of posterior lens surface curvature (RPL) decreased significantly. The changes in the anterior ocular parameters during 4-D accommodation were similar to those for the 2-D accommodation. \\begin{document}\

  11. Corneal toxicity induced by vesicating agents and effective treatment options

    PubMed Central

    Goswami, Dinesh G.; Tewari-Singh, Neera; Agarwal, Rajesh

    2016-01-01

    The vesicating agents sulfur mustard (SM) and lewisite (LEW) are potent chemical warfare agents that primarily cause damage to the ocular, skin, and respiratory systems. However, ocular tissue is the most sensitive organ, and vesicant exposure results in a biphasic injury response, including photophobia, corneal lesions, corneal edema, ulceration, and neovascularization, and may cause loss of vision. There are several reports on ocular injury from exposure to SM, which has been frequently used in warfare. However, there are very few reports on ocular injury by LEW, which indicate that injury symptoms appear instantly after exposure and faster than SM. In spite of extensive research efforts, effective therapies for vesicant-induced ocular injuries, mainly to the most affected corneal tissue, are not available. Hence, we have established primary human corneal epithelial (HCE) cells and rabbit corneal organ culture models with the SM analog nitrogen mustard (NM), which have helped to test the efficacy of potential therapeutic agents. These agents will then be further evaluated against in vivo SM- and LEW-induced corneal injury models, which will assist in the development of potential broad-spectrum therapies against vesicant-induced ocular injuries. PMID:27327041

  12. Trehalose protects against ocular surface disorders in experimental murine dry eye through suppression of apoptosis.

    PubMed

    Chen, Wei; Zhang, Xiaobo; Liu, Mimi; Zhang, Jingna; Ye, Ya; Lin, Ying; Luyckx, Jacques; Qu, Jia

    2009-09-01

    The disaccharide trehalose is a key element involved in anhydrobiosis (the capability of surviving almost complete dehydration) in many organisms. Its presence also confers resistance to desiccation and high osmolarity in bacterial and human cells by protecting proteins and membranes from denaturation. The present study used a novel murine dry eye model induced by controlled low-humidity air velocity to determine whether topically applied trehalose could heal ocular surface epithelial disorders caused by ocular surface desiccation. In addition, the efficacy of 87.6 mM trehalose eyedrops was compared with that of 20% serum, the efficacy of which has been well documented. Mice ocular surface epithelial disorders were induced by exposure of murine eyes to continuous controlled low-humidity air velocity in an intelligently controlled environmental system (ICES) for 21 days, which accelerated the tear evaporation. The mice were then randomized into three groups: the control group received PBS (0.01 M) treatment; a second group received 87.6 mM trehalose eyedrops treatment; and the third group received mice serum eyedrops treatment. Each treatment was administered as a 10 microl dose every 6 h for 14 days. The resultant changes in corneal barrier function and histopathologic examination of cornea and conjunctiva were analyzed and the level of apoptosis on the ocular surface was assessed using active caspase-3. After 14 days of treatment, the corneal fluorescein staining area, the ruffling and desquamating cells on the apical corneal epithelium, as well as the apoptotic cells on ocular surface epithelium had significantly reduced in eyes treated with trehalose compared with those treated with serum and PBS. In contrast, after 14 days of treatment, improvements in the thickness of the corneal epithelium, the squamous metaplasia in conjunctival epithelium and the number of goblet cells of the conjunctiva were less marked in eyes treated with trehalose compared with serum. These results demonstrated that trehalose could improve the appearance of ocular surface epithelial disorders due to desiccation through suppression of apoptosis. Trehalose produces some of the same responses as serum upon topical application and can maintain corneal health.

  13. Glycobiology of the ocular surface: Mucins and lectins

    PubMed Central

    Argüeso, Pablo

    2013-01-01

    Glycosylation is an important and common form of posttranscriptional modification of proteins in cells. A vast array of biological functions has been ascribed to glycans during the last decade thanks to a rapid evolution in glycomic technologies. Glycogenes highly expressed at the human ocular surface include families of glycosyltransferases, proteoglycans, glycan degradation proteins, as well as mucins and carbohydrate-binding proteins such as the galectins. On the apical glycocalyx, mucin O-glycans promote boundary lubrication, prevent bacterial adhesion and endocytic activity, and maintain epithelial barrier function through interactions with galectins. The emerging roles attributed to glycans are contributing to the appreciation of their biological capabilities at the ocular surface. PMID:23325272

  14. Improvements in Signs and Symptoms of Dry Eye after Instillation of 2% Rebamipide.

    PubMed

    Igarashi, Tsutomu; Fujita, Miho; Yamada, Yumi; Kobayashi, Maika; Fujimoto, Chiaki; Takahashi, Hisatomo; Igarashi, Toru; Nakano, Yuichiro; Suzuki, Hisaharu; Takahashi, Hiroshi

    2015-01-01

    Because dry eye greatly reduces quality of life, this study aimed to examine rebamipide instillation in patients with dry eye and assess the improvement of signs and symptoms as evaluated with the Ocular Surface Disease Index, which is the most popular index and is highly reliable. From June 2013 through January 2014, we examined 50 eyes of 25 patients with dry eye (6 men and 19 woman) at our institution. Dry eye was diagnosed on the basis of the presence of symptoms, tear dynamics, and ocular surface abnormalities according to the Japanese criteria for dry eye. Before being enrolled, all patients underwent ocular surface health assessment, including history interviews, and completed the Ocular Surface Disease Index questionnaire. Patients received 2% rebamipide ophthalmic solution 4 times daily for 4 weeks. Signs and symptoms were analyzed before and 4 weeks after rebamipide administration. Tear dynamics, tear break-up time, and ocular surface abnormalities were measured and compared between before and 4 weeks after rebamipide administration. Of the 25 patients, 9 had definite dry eye and 16 had probable dry eye. Tear break-up time and the fluorescein staining score significantly improved after 4 weeks. However, no significant change was observed for the Schirmer test I and the lissamine green staining score. The administration of 2% rebamipide 4 times daily for 4 weeks improves the signs and symptoms of dry eye and improves patients' quality of life.

  15. Profiling extractable and leachable inorganic impurities in ophthalmic drug containers by ICP-MS.

    PubMed

    Solomon, Paige; Nelson, Jenny

    2018-03-01

    In this study, we investigated the elemental impurities present in the plastic material of ophthalmic eye drop bottles using inductively coupled plasma-mass spectrometry (ICP-MS). Metallic contaminations, especially localized within the small cavity of the eye, can significantly perturb the ocular metallome. The concern is two-fold: first certain elements, for example heavy metals, can be toxic to humans at even trace levels, and second, these contaminations can have adverse reactions with other medicines or enzymatic processes in the eye. The implication of redox-active metals in cataract formation is one such biological consequence. The analysis demonstrated the effect of aggressive storage and transportation conditions on elemental extractable and leachable contamination, and posits that release of these elemental impurities can disrupt metallome equilibrium in the ocular compartment, leading to toxicity and disease.

  16. Plasma Rich in Growth Factors for the Treatment of Ocular Surface Diseases.

    PubMed

    Anitua, Eduardo; Muruzabal, Francisco; de la Fuente, María; Merayo, Jesús; Durán, Juan; Orive, Gorka

    2016-07-01

    The purpose of this work is to describe and review the technology of plasma rich in growth factors (PRGF), a novel blood derivative product, in the treatment of ocular surface disorders. To demonstrate the importance of this technology in the treatment of ocular pathologies, a thorough review of the preclinical and clinical literature results obtained following use of the different therapeutic formulations of PRGF was carried out. A literature search for applications of PGRF plasma in the ophthalmology field was carried out using the PubMed database. PRGF involves the use of patient's own biologically active proteins, growth factors, and biomaterial scaffolds for therapeutic purposes. This procedural technology is gaining interest in regenerative medicine due to its potential to stimulate and accelerate the tissue healing processes. The versatility and biocompatibility of this technology opens the door to a personalized medicine on ocular tissue regeneration. This review discusses the state of the art of the new treatments and technologies developed to promote ocular surface tissue regeneration. The standardized protocol that has been developed to source eye drops from PRGF technology is also described. The preclinical research, together with the most relevant clinical applications are summarized and discussed. The preliminary results suggest that the use of PRGF to enhance ocular tissue regeneration is safe and efficient.

  17. Impact of wildfire smoke in Buenos Aires, Argentina, on ocular surface.

    PubMed

    Berra, Martin; Galperín, Gustavo; Dawidowski, Laura; Tau, Julia; Márquez, Isabel; Berra, Alejandro

    2015-01-01

    To evaluate the acute impact of the wildfire smoke episode in 2008 on the ocular surface of subjects living in the Metropolitan Area of Buenos Aires (MABA). A total of 86 subjects were evaluated: Group 1 comprised patients from a public ophthalmology hospital (N=35) and Group 2 comprised healthy volunteers (N=51). All subjects answered a questionnaire on ocular symptoms and underwent ophthalmologic examination [bulbar conjunctival hyperemia, corneal fluorescein staining, rose bengal vital staining, tear break-up time (TBUT), Schirmer I test, tear lysozyme, and impression cytology] during and after the acute episode. Concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), and particulate matter (PM) were measured before, during, and after the acute episode. Both groups showed a statically significant increase in ocular symptoms and bulbar conjunctival hyperemia and a statically significant decrease in tear break-up time during the acute episode. Group 1 showed more severe symptoms and a statistically significant increase in fluorescein and rose bengal staining intensities during the acute episode. We found a significant negative correlation between ocular symptoms and tear break-up time. During the episode, the levels of CO, NO2, and particulate matter in MABA were four times higher than the usual average levels for the same period in 2007 and 2009. Increased air pollution from the burning of biomass is associated with a decrease in the stability of the tear film (TBUT), generating areas of ocular surface exposure that may be the cause of the increased feeling of irritation. Group 1 was more affected by not having a healthy ocular surface, and thus consulted an ophthalmologist. Cytological changes in the conjunctiva were not observed, which could be due to the short duration of the episode.

  18. Retinal toxicity associated with chronic exposure to hydroxychloroquine and its ocular screening. Review.

    PubMed

    Geamănu Pancă, A; Popa-Cherecheanu, A; Marinescu, B; Geamănu, C D; Voinea, L M

    2014-09-15

    Hydroxychloroquine sulfate (HCQ, Plaquenil) is an analogue of chloroquine (CQ), an antimalarial agent, used for the treatment of systemic lupus erythematosus, rheumatoid arthritis and other autoimmune disorders. Its use has been associated with severe retinal toxicity, requiring a discontinuation of therapy. Because it presents potential secondary effects including irreversible maculopathy, knowledge of incidence, risk factors, drug toxicity and protocol screening of the patients it represents important data for the ophthalmologists. Thus, it is imperative that rheumatologists, medical internists and ophthalmologists are aware of the toxicity from hydroxychloroquine they should also be careful to minimize its occurrence and effects.

  19. Salvage/Adjuvant Brachytherapy After Ophthalmic Artery Chemosurgery for Intraocular Retinoblastoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Francis, Jasmine H., E-mail: francij1@mskcc.org; Barker, Christopher A.; Wolden, Suzanne L.

    2013-11-01

    Purpose: To evaluate the efficacy and toxicity of brachytherapy after ophthalmic artery chemosurgery (OAC) for retinoblastoma. Methods and Materials: This was a single-arm, retrospective study of 15 eyes in 15 patients treated with OAC followed by brachytherapy at (blinded institution) between May 1, 2006, and December 31, 2012, with a median 19 months' follow-up from plaque insertion. Outcome measurements included patient and ocular survival, visual function, and retinal toxicity measured by electroretinogram (ERG). Results: Brachytherapy was used as adjuvant treatment in 2 eyes and as salvage therapy in 13 eyes of which 12 had localized vitreous seeding. No patients developedmore » metastasis or died of retinoblastoma. The Kaplan-Meier estimate of ocular survival was 79.4% (95% confidence interval 48.7%-92.8%) at 18 months. Three eyes were enucleated, and an additional 6 eyes developed out-of-target volume recurrences, which were controlled with additional treatments. Patients with an ocular complication had a mean interval between last OAC and plaque of 2.5 months (SD 2.3 months), which was statistically less (P=.045) than patients without ocular complication who had a mean interval between last OAC and plaque of 6.5 months (SD 4.4 months). ERG responses from pre- versus postplaque were unchanged or improved in more than half the eyes. Conclusions: Brachytherapy following OAC is effective, even in the presence of vitreous seeding; the majority of eyes maintained stable or improved retinal function following treatment, as assessed by ERG.« less

  20. Association between clinical diagnostic tests and health-related quality of life surveys in patients with dry eye syndrome.

    PubMed

    Mizuno, Yoshinobu; Yamada, Masakazu; Miyake, Yozo

    2010-07-01

    This study was performed to assess the impact of dry eye on patients' quality of life (QOL) and to analyze the association between subjective symptoms and ocular surface findings of dry eye. The study population consisted of 158 patients with dry eye aged 20 years or older who visited any of the 15 medical care facilities enrolled in the study. The backgrounds and ocular findings of the patients were investigated, and their QOL was evaluated with the Japanese version of the 25-item National Eye Institute Visual Functioning Questionnaire (VFQ-25) and of the Medical Outcomes Study (MOS) 8-item Short-Form Health Survey (SF-8) to examine the association between subjective symptoms and ocular surface findings. Of the patients enrolled, 15 were men and 143 were women, and their average age was 62.5 +/- 12.6 years. Sixty patients (38.0%) had comorbid Sjögren syndrome (SS). The results of Schirmer testing, fluorescein staining, and rose bengal staining for SS patients were significantly worse than those for the non-SS patients, but the VFQ-25 and SF-8 scores were not significantly different between the SS and non-SS patients. In the ocular surface findings, a weak association between the fluorescein staining scores and general vision scores, a subscale of the VFQ-25, was found. However, the ocular surface findings and VFQ-25/SF-8 results in the simple correlation analysis as well as in the multiple linear regression analysis showed no significant associations. Ocular surface findings and QOL scores of patients with dry eye appear to disagree. Therefore, it is necessary to address subjective symptoms and QOL scores in addition to examination findings when evaluating dry eye.

  1. The Ocular Surface Chemical Burns

    PubMed Central

    Baradaran-Rafii, Alireza; Djalilian, Ali R.

    2014-01-01

    Ocular chemical burns are common and serious ocular emergencies that require immediate and intensive evaluation and care. The victims of such incidents are usually young, and therefore loss of vision and disfigurement could dramatically affect their lives. The clinical course can be divided into immediate, acute, early, and late reparative phases. The degree of limbal, corneal, and conjunctival involvement at the time of injury is critically associated with prognosis. The treatment starts with simple but vision saving steps and is continued with complicated surgical procedures later in the course of the disease. The goal of treatment is to restore the normal ocular surface anatomy and function. Limbal stem cell transplantation, amniotic membrane transplantation, and ultimately keratoprosthesis may be indicated depending on the patients' needs. PMID:25105018

  2. Efficacy and Safety of Carbomer-Based Lipid-Containing Artificial Tear Formulations in Patients With Dry Eye Syndrome.

    PubMed

    Chung, So-Hyang; Lim, Sung A; Tchach, Hungwon

    2016-02-01

    To evaluate the efficacy and safety profile of carbomer-based lipid-containing artificial tear formulations (CBLAT) in patients with dry eye syndrome. A multicenter parallel-group study was conducted in 412 patients with dry eye syndrome. Of these patients, 221 switched from using artificial tears to CBLAT (switching group) and 191 added CBLAT to their current treatment (add-on group). Ocular symptom scores, ocular staining grades, tear film breakup time (tBUT), Schirmer I test value, and Korean dry eye level (as defined by the Korean Corneal Disease Study Group guidelines) were evaluated at baseline and after 4 weeks of treatment. After 4 weeks of treatment, ocular surface staining grade, tBUT, Schirmer I value, ocular irritation symptom scores, and the positive rate of visual symptom improved significantly in both groups. Mean reductions in ocular surface staining grades (-0.8 ± 0.9) and ocular irritation symptom scores (-0.8 ± 0.8) in the add-on group were significantly higher than those (-0.5 ± 0.8 and -0.6 ± 0.8) in the switching group (P < 0.01 and P < 0.05). The positive rate of visual symptoms (44.2%) in the add-on group was significantly higher than that (26.4%) in the switching group (P < 0.01). The decrease of Korean dry eye level was 30.1% in the switching group and 51.6% in the add-on group. More patients in the add-on group had decreased dry eye levels than those in the switching group (P < 0.0001). CBLAT improves ocular surface staining grades, tBUT, Schirmer I values, and ocular symptoms in patients with dry eye syndrome.

  3. Dry Eye as a Mucosal Autoimmune Disease

    PubMed Central

    Stern, Michael E.; Schaumburg, Chris S.; Pflugfelder, Stephen C.

    2013-01-01

    Dry eye is a common ocular surface inflammatory disease that significantly affects quality of life. Dysfunction of the lacrimal function unit (LFU) alters tear composition and breaks ocular surface homeostasis, facilitating chronic inflammation and tissue damage. Accordingly, the most effective treatments to date are geared towards reducing inflammation and restoring normal tear film. The pathogenic role of CD4+ T cells is well known, and the field is rapidly realizing the complexity of other innate and adaptive immune factors involved in the development and progression of disease. The data support the hypothesis that dry eye is a localized autoimmune disease originating from an imbalance in the protective immunoregulatory and proinflammatory pathways of the ocular surface. PMID:23360156

  4. The role of the lacrimal functional unit in the pathophysiology of dry eye.

    PubMed

    Stern, Michael E; Gao, Jianping; Siemasko, Karyn F; Beuerman, Roger W; Pflugfelder, Stephen C

    2004-03-01

    The majority of dry eye symptoms are due to a chronic inflammation of the lacrimal functional unit resulting in a loss of tear film integrity and normal function. This leads to a reduction in the ability of the ocular surface to respond to environmental challenges. The underlying cause of tear film dysfunction is the alteration of tear aqueous, mucin, and lipid components. This may result from a systemic autoimmune disease or a local autoimmune event. A lack of systemic androgen support to the lacrimal gland has been shown to be a facilitative factor in the initiation of this type of pathophysiology. Tear secretion is controlled by the lacrimal functional unit consisting of the ocular surface (cornea, conjunctiva, accessory lacrimal glands, and meibomian glands), the main lacrimal gland and the interconnecting innervation. If any portion of this functional unit is compromised, lacrimal gland support to the ocular surface is impeded. Factors such as neurogenic inflammation and T cell involvement in the disease pathogenesis as well as newly developed animal models of ocular surface inflammation are discussed.

  5. Lacrimal gland-derived IL-22 regulates IL-17-mediated ocular mucosal inflammation

    PubMed Central

    Ji, Yong Woo; Mittal, Sharad K.; Hwang, Ho Sik; Chang, Eun-Ju; Lee, Joon H.; Seo, Yuri; Yeo, Areum; Noh, Hyemi; Lee, Hye Sun; Chauhan, Sunil K.; Lee, Hyung Keun

    2016-01-01

    Inflammatory damage of mucosal surface of the eye is a hallmark of dry eye disease (DED), and in severe cases can lead to significant discomfort, visual impairment, and blindness. DED is a multifactorial autoimmune disorder with a largely unknown pathogenesis. Using a cross-sectional patient study and a well-characterized murine model of DED, herein we investigated the immunoregulatory function of interleukin-22 (IL-22) in the pathogenesis of DED. We found that IL-22 levels were elevated in lacrimal fluids of DED patients and inversely correlated with severity of disease. Acinar cells of the lacrimal glands, not inflammatory immune cells, are the primary source of IL-22, which suppresses inflammation in ocular surface epithelial cells upon desiccating stress. Moreover, loss of function analyses using IL-22 knock-out mice demonstrated that IL-22 is essential for suppression of ocular surface infiltration of Th17 cells and inhibition of DED induction. Our novel findings elucidate immunoregulatory function of lacrimal gland-derived IL-22 in inhibiting IL-17-mediated ocular surface epitheliopathy in DED thus making IL-22 a new relevant therapeutic target. PMID:28051088

  6. Biomaterials and Tissue Engineering Strategies for Conjunctival Reconstruction and Dry Eye Treatment

    PubMed Central

    Lu, Qiaozhi; Al-Sheikh, Osama; Elisseeff, Jennifer H.; Grant, Michael P.

    2015-01-01

    The ocular surface is a component of the anterior segment of the eye and is covered by the tear film. Together, they protect the vital external components of the eye from the environment. Injuries, surgical trauma, and autoimmune diseases can damage this system, and in severe cases, tissue engineering strategies are necessary to ensure proper wound healing and recovery. Dry eye is another major concern and a complicated disease affecting the ocular surface. More effective and innovative therapies are required for better outcomes in treating dry eye. This review focuses on the regenerative medicine of the conjunctiva, which is an essential part of the ocular surface system. Features and advances of different types of biomolecular materials, and autologous and allogeneic tissue grafts are summarized and compared. Specifically, vitrigel, a collagen membrane and novel material for use on the ocular surface, offers significant advantages over other biomaterials. This review also discusses a breakthrough microfluidic technology, “organ-on-a-chip” and its potential application in investigating new therapies for dry eye. PMID:26692712

  7. Analysis of the Pathogenic Factors and Management of Dry Eye in Ocular Surface Disorders.

    PubMed

    Nebbioso, Marcella; Del Regno, Paola; Gharbiya, Magda; Sacchetti, Marta; Plateroti, Rocco; Lambiase, Alessandro

    2017-08-13

    The tear film represents the interface between the eye and the environment. The alteration of the delicate balance that regulates the secretion and distribution of the tear film determines the dry eye (DE) syndrome. Despite having a multifactorial origin, the main risk factors are female gender and advanced age. Likewise, morphological changes in several glands and in the chemical composition of their secretions, such as proteins, mucins, lipidics, aqueous tears, and salinity, are highly relevant factors that maintain a steady ocular surface. Another key factor of recurrence and onset of the disease is the presence of local and/or systemic inflammation that involves the ocular surface. DE syndrome is one of the most commonly encountered diseases in clinical practice, and many other causes related to daily life and the increase in average life expectancy will contribute to its onset. This review will consider the disorders of the ocular surface that give rise to such a widespread pathology. At the end, the most recent therapeutic options for the management of DE will be briefly discussed according to the specific underlying pathology.

  8. Analysis of the Pathogenic Factors and Management of Dry Eye in Ocular Surface Disorders

    PubMed Central

    Del Regno, Paola; Sacchetti, Marta; Plateroti, Rocco

    2017-01-01

    The tear film represents the interface between the eye and the environment. The alteration of the delicate balance that regulates the secretion and distribution of the tear film determines the dry eye (DE) syndrome. Despite having a multifactorial origin, the main risk factors are female gender and advanced age. Likewise, morphological changes in several glands and in the chemical composition of their secretions, such as proteins, mucins, lipidics, aqueous tears, and salinity, are highly relevant factors that maintain a steady ocular surface. Another key factor of recurrence and onset of the disease is the presence of local and/or systemic inflammation that involves the ocular surface. DE syndrome is one of the most commonly encountered diseases in clinical practice, and many other causes related to daily life and the increase in average life expectancy will contribute to its onset. This review will consider the disorders of the ocular surface that give rise to such a widespread pathology. At the end, the most recent therapeutic options for the management of DE will be briefly discussed according to the specific underlying pathology. PMID:28805710

  9. Ocular Toxicity Secondary to Asclepias physocarpa: The Balloon Plant

    PubMed Central

    Pina, Susana; Pedrosa, Catarina; Santos, Cristina; Feijóo, Bernardo; Pego, Peter; Vendrell, Cristina; Santos, Maria João; Prieto, Isabel

    2014-01-01

    We report a case of a 65-year-old woman with symptoms of blurred vision and ocular irritation a few hours after accidental contact of the right eye with Asclepias physocarpa milky latex. Observation showed a diffuse conjunctival hyperemia and stromal corneal edema with Descemet's membrane folds. Recovery was fast and apparently complete in less than one month. However, specular microscopy at 6-months follow-up showed an abnormal endothelial morphology as sequelae, suggesting this condition is not as innocuous as it has been suggested. PMID:25105044

  10. Ocular toxoplasmosis II: clinical features, pathology and management

    PubMed Central

    Butler, Nicholas J; Furtado, João M; Winthrop, Kevin L; Smith, Justine R

    2014-01-01

    The term, ocular toxoplasmosis, refers to eye disease related to infection with the parasite, Toxoplasma gondii. Recurrent posterior uveitis is the typical form of this disease, characterized by unilateral, necrotizing retinitis with secondary choroiditis, occurring adjacent to a pigmented retinochoroidal scar and associated with retinal vasculitis and vitritis. Multiple atypical presentations are also described, and severe inflammation is observed in immunocompromised patients. Histopathological correlations demonstrate focal coagulative retinal necrosis, and early in the course of the disease, this inflammation is based in the inner retina. For typical ocular toxoplasmosis, a diagnosis is easily made on clinical examination. In atypical cases, ocular fluid testing to detect parasite DNA by polymerase chain reaction or to determine intraocular production of specific antibody may be extremely helpful for establishing aetiology. Given the high seroprevalence of toxoplasmosis in most communities, serological testing for T. gondii antibodies is generally not useful. Despite a lack of published evidence for effectiveness of current therapies, most ophthalmologists elect to treat patients with ocular toxoplasmosis that reduces or threatens to impact vision. Classic therapy consists of oral pyrimethamine and sulfadiazine, plus systemic corticosteroid. Substantial toxicity of this drug combination has spurred interest in alternative antimicrobials, as well as local forms of drug delivery. At this time, however, no therapeutic approach is curative of ocular toxoplasmosis. PMID:22712598

  11. Dermal Sensitization Potential of Triethyleneglycol Dinitrate (TEGDN) in Guinea Pigs

    DTIC Science & Technology

    1989-01-01

    mutagenicity assay, acute oral toxicity tests in rats and mice, acute dermal toxicity in rabbits, dermal and ocular irritation studies in rabbits, and...conditions: 85E0102 had diffuse tracheitis, mild endocarditis , mild hepatitis, and diffuse pigment granules in the small intestine; 85E0103 had mild...severe ulceration progressing to necrosis. Sensitization is manifested as indirect inflammation mediated by components of the immune system in

  12. Ocular surface and tear film status among contact lens wearers and non-wearers who use VDT at work: comparing three different lens types.

    PubMed

    Tauste, Ana; Ronda, Elena; Baste, Valborg; Bråtveit, Magne; Moen, Bente E; Seguí Crespo, María-Del-Mar

    2018-04-01

    To analyze differences in the ocular surface appearance and tear film status of contact lens wearers and non-wearers in a group of visual display terminals (VDT) workers and additionally to assess differences between lens materials. Cross-sectional study of 236 office workers, of whom 92 were contact lens wearers. Workers provided information on their contact lenses (conventional hydrogel, silicone hydrogel or rigid gas permeable lenses) and exposure to VDT at work. Ocular surface and tear film status were determined by the presence of bulbar, limbal and lid redness, lid roughness and corneal staining type, and by Schirmer's and tear break-up time tests (TBUT). A generalized linear model was used to calculate the crude (cRR) and age- and sex-adjusted (aRR) relative risk to measure the association between ocular surface and tear film abnormalities and contact lens use and type. The aRR of ocular surface abnormalities was higher in contact lens wearers compared to non-wearers: bulbar redness (aRR 1.69; 95% CI 1.25-2.30), limbal redness (aRR 2.87; 1.88-4.37), lid redness (aRR 2.53; 1.35-4.73) and lid roughness (aRR 7.03; 1.31-37.82). VDT exposure > 4 h/day increased wearers' risk of limbal and lid redness. Conventional hydrogel wearers had the highest risk of ocular surface abnormalities, followed by silicone hydrogel wearers. Both contact and non-contact lens wearers had a high prevalence of altered TBUT (77.3 and 75.7% respectively) and Schirmer (51.8 and 41.3%). Regular contact lens use during VDT exposure at work increases risk of bulbar, limbal and lid redness, and lid roughness, especially in soft contact lens wearers. The high prevalence of altered TBUT and Schirmer's results in all participants suggests that VDT use greatly affects tear film characteristics.

  13. Safety and toxicity of nanomaterials for ocular drug delivery applications.

    PubMed

    Mehra, Neelesh K; Cai, Defu; Kuo, Lih; Hein, Travis; Palakurthi, Srinath

    2016-09-01

    Multifunctional nanomaterials are rapidly emerging for ophthalmic delivery of therapeutics to facilitate safe and effective targeting with improved patient compliance. Because of their extremely high area to volume ratio, nanomaterials often have physicochemical properties that are different from those of their larger counterparts. There exists a complex relationship between the physicochemical properties (composition, size, shape, charge, roughness, and porosity) of the nanomaterials and their interaction with the biological system. The eye is a very sensitive accessible organ and is subjected to intended and unintended exposure to nanomaterials. Currently, various ophthalmic formulations are available in the market, while some are underway in preclinical and clinical phases. However, the data on safety, efficacy, and toxicology of these advanced nanomaterials for ocular drug delivery are sparse. Focus of the present review is to provide a comprehensive report on the safety, biocompatibility and toxicities of nanomaterials in the eye.

  14. Ocular surface alterations and in vivo confocal microscopic characteristics of corneas in patients with myasthenia gravis.

    PubMed

    Erkan Turan, Kadriye; Kocabeyoglu, Sibel; Bekircan-Kurt, Can Ebru; Bezci, Figen; Erdem-Ozdamar, Sevim; Irkec, Murat

    2018-03-01

    To evaluate ocular surface alterations and characteristics of corneal basal epithelium and subbasal nerves in patients with myasthenia gravis. Myasthenia gravis patients (n = 21) and healthy controls (n = 20) were enrolled. All participants underwent ocular surface testing in the following order: tear break-up time, lissamine green staining, Schirmer I test with anesthesia, and Ocular Surface Disease Index questionnaire. The Cochet-Bonnet esthesiometer was used to measure corneal sensitivity. Basal epithelial cells and subbasal nerves were evaluated using in vivo confocal microscopy. Myasthenia gravis patients had higher Ocular Surface Disease Index score (13.9 ± 15.0 vs 1.4 ± 2.2, p < 0.001) and lissamine green staining score (0.6 ± 0.4 vs 0.2 ± 0.4, p = 0.007). Break-up time score (9.3 ± 3.0 vs 9.9 ± 1.9, p = 0.481) and Schirmer I test score (16.5 ± 9.2 vs 19.3 ± 8.4, p = 0.323) did not differ significantly. Corneal sensation was 0.4 g/mm 2 in all eyes. Patients with myasthenia gravis had lower basal epithelial cell density (3775.7 ± 938.1 vs 4983.1 ± 608.5, p < 0.001) and total nerve density (1956.1 ± 373.3 vs 2277.9 ± 405.0, p = 0.012) and higher subbasal nerve tortuosity (1.9 ± 0.8 vs 1.6 ± 0.7, p = 0.007) than controls. A significant increase in Ocular Surface Disease Index scores was found with decreasing basal epithelial cell density (rho = -0.518, p = 0.001). There was a significantly moderate negative correlation between the duration of myasthenia gravis and the number of corneal nerves (rho = -0.497, p = 0.022). Significant alterations of basal epithelial cells and subbasal nerves were demonstrated in myasthenia gravis patients although there was no difference of corneal sensitivity between myasthenia gravis patients and healthy controls. Thus, it should be borne in mind that myasthenia gravis patients deserve further evaluation with regard to ocular surface disease.

  15. Mucin gene expression is not regulated by estrogen and/or progesterone in the ocular surface epithelia of mice.

    PubMed

    Lange, Christine; Fernandez, Jolene; Shim, David; Spurr-Michaud, Sandra; Tisdale, Ann; Gipson, Ilene K

    2003-07-01

    Dry eye syndrome is prevalent in post-menopausal women, and post-menopausal women secrete less mucus in their reproductive tracts. Using a mouse model, the purpose of this study was to determine if estrogen and/or progesterone regulates Muc4 and Muc5AC gene expression in the ocular surface epithelia, as the hormones do in reproductive tract epithelia. Adult C57BL/6 mice were ovariectomized, and 19 days later, pellets containing estrogen, progesterone, or a combination were inserted subcutaneously. Ocular surface and reproductive tract tissues were harvested following seven days of hormone treatment. A control group consisted of ovariectomized mice that received no hormone treatment. Real-time reverse transcription-polymerase chain reaction was used to determine the tissue expression levels of mucin mRNA of each treatment group relative to the control. Muc4 mRNA expression levels were determined for the reproductive tract, and both Muc4 and Muc5AC expression levels were determined for the ocular surface epithelia. Muc4 and Muc5AC gene expression in ocular surface and Muc4 in reproductive tract epithelia was demonstrated by In Situ hybridization, and Muc4 and Muc5AC protein was demonstrated in the epithelia of animals in the experimental groups. The mRNA expression levels of Muc4 and Muc5AC and the immunofluorescence localization pattern in the ocular surface epithelia were not significantly different in any hormone treatment group when compared to the control ovariectomized group. By comparison, mice that were administered estrogen had a significant increase of Muc4 mRNA in the reproductive tract epithelia, progesterone given in combination with estrogen antagonized the upregulatory effects of estrogen in the reproductive tract, and the amount of Muc4 mRNA in the reproductive tract of progesterone-treated animals was not different from ovariectomized controls. Immunofluorescence localization of Muc4 in the reproductive tract epithelia of the experimental groups correlated to message levels, with lack of Muc4 protein detected in the control and progesterone groups. In comparison to reproductive tract epithelia, Muc4 and Muc5AC are not hormonally regulated by estrogen or progesterone in the ocular surface epithelia of mice. These data demonstrate that regulation of epithelial mucin genes is tissue specific.

  16. Local synthesis of sex hormones: are there consequences for the ocular surface and dry eye?

    PubMed

    Gibson, Emma J; Stapleton, Fiona; Wolffsohn, James S; Golebiowski, Blanka

    2017-12-01

    Sex hormones are associated with the physiology and pathophysiology of almost all organs in the body, as well as most diseases. Interest in the associations between sex hormones and ocular tissues has increased in recent years. Androgens may have a positive effect on dry eye, whereas the effects of oestrogen on ocular conditions remain unclear. Intracrinology, the local synthesis and metabolism of hormones that is unique to humans, is of relevance to the eye and may help to explain why studies of the relationship between oestrogens and dry eye signs and symptoms are inconclusive. Knowledge of the pathways of hormone formation and metabolism is crucial to understanding the pathogenesis of ocular disease including dry eye. This review examines the mechanisms of steroidal sex hormone biosynthesis and reviews the significance of locally produced sex hormones, with a focus on ocular surface tissues. Much of the current literature is based on animal studies, which may not be transferable to humans due to the absence of intracrine production in animals. A large proportion of the human studies investigate systemic hormone levels rather than local levels. There is subsequently a need for additional studies to provide a better understanding of the local production of sex hormones within the human eye and ocular surface and to clarify the relationships between ocular levels of sex hormones and conditions including dry eye. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Preservative-free treatment in glaucoma: who, when, and why.

    PubMed

    Stalmans, Ingeborg; Sunaric Mégevand, Gordana; Cordeiro, M Francesca; Hommer, Anton; Rossetti, Luca; Goñi, Francisco; Heijl, Anders; Bron, Alain

    2013-01-01

    To review and summarize the available literature on the effect of preservatives on the eye, to provide practical guidance for the clinical assessment of the ocular surface in glaucoma patients, and to define patient populations that might benefit from preservative-free topical intraocular pressure (IOP)-lowering agents. This manuscript is based on a combination of a literature review on preservatives and the eye and expert opinion from glaucoma specialists with an interest in ocular surface disease. There is an increasingly recognized association between eyedrop preservatives and ocular surface disease. Preservative-free therapy is now available for a wide range of active compounds, although there are still some misconceptions regarding their appropriate use. For patients treated topically for glaucoma or ocular hypertension, a rough estimate could be that 20% may need treatment with topical IOP-reducing agents that are free from preservatives. This review provides an up-to-date account of the literature regarding preservatives and the eye, as well as suggestions and recommendations on to when to use preservative-free antiglaucoma treatment.

  18. Therapeutic use of mini-scleral lenses in a patient with Graves' ophthalmopathy.

    PubMed

    Harthan, Jennifer S

    2014-01-01

    Patients with Graves' ophthalmopathy can be very challenging to manage secondary to the complex nature of their disease presentation. Patients may present with a variety of ocular findings including: lid retraction, periorbital and lid swelling, chemosis, conjunctival hyperemia, proptosis, optic neuropathy, restrictive myopathy, exposure keratopathy and/or keratoconjunctivitis sicca. Mini-scleral and scleral lens designs have been important in the management of irregular and regular corneas, and in the therapy of ocular surface diseases. We present here the case of a 48-year-old Caucasian male who had been diagnosed with Graves' ophthalmopathy 13 years earlier. With significant ocular surface staining and over ten diopters of astigmatism, the patient had never been able to wear contact lenses comfortably. After being fit with the Mini-Scleral Design™ lenses, his vision improved to 20/25 OU, his ocular surface improved, and overall quality of vision increased. Copyright © 2012 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  19. Retinal toxicity associated with chronic exposure to hydroxychloroquine and its ocular screening. Review

    PubMed Central

    Geamănu (Pancă), A; Popa-Cherecheanu, A; Marinescu, B; Geamănu, CD; Voinea, LM

    2014-01-01

    Abstract Hydroxychloroquine sulfate (HCQ, Plaquenil) is an analogue of chloroquine (CQ), an antimalarial agent, used for the treatment of systemic lupus erythematosus, rheumatoid arthritis and other autoimmune disorders. Its use has been associated with severe retinal toxicity, requiring a discontinuation of therapy. Because it presents potential secondary effects including irreversible maculopathy, knowledge of incidence, risk factors, drug toxicity and protocol screening of the patients it represents important data for the ophthalmologists. Thus, it is imperative that rheumatologists, medical internists and ophthalmologists are aware of the toxicity from hydroxychloroquine they should also be careful to minimize its occurrence and effects. PMID:25408748

  20. Insects have hairy eyes that reduce particle deposition

    NASA Astrophysics Data System (ADS)

    Amador, G. J.; Durand, F.; Mao, W.; Pusulri, S.; Takahashi, H.; Nguyen, V.-T.; Shimoyama, I.; Alexeev, A.; Hu, D. L.

    2015-12-01

    An insect's eyes may make up to 40% of its body's surface, and are in danger of being coated by foreign particles such as dust and pollen. To protect them, several insect species possess an array of ocular hairs evenly spaced between each photoreceptor unit. Although these hairs have been observed for over 50 years, their purpose remains a mystery. In this study, we elucidate the function of ocular hairs using a combination of experiments, numerical simulation and micro-fabrication. We measure the eyes of 18 species of insects and find that the length of their ocular hairs is equal to their spacing. We conduct wind tunnel experiments using both an insect eye mimic and an at-scale fabricated micro-pillar array of the same dimensions as the insect eye. Our experiments and simulations show that ocular hairs reduce airflow at the eye surface by up to 90%. We conclude that ocular hairs act similarly to mammalian eyelashes: as insects fly, ocular hairs deflect incoming air and create a zone of stagnant air. Airflow and particle deposition are reduced dramatically, while light is only minimally occluded. Micro-scale ocular hairs may find application in the deployment of sensors outdoors, for which accumulation of airborne dust and pollen has no current solution.

  1. A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS

    PubMed Central

    Deng, Quan; Braun, R. J.; Driscoll, T. A.; King-Smith, P. E.

    2015-01-01

    In this paper, we investigate the dynamics of tear film and the associated temperature variation for partial blinks. We investigate the mechanism of fluid supply during partial blink cycles, and compare the film thickness with observation in vivo. We find that varying the thickness of the fluid layer beneath the moving upper lid improves the agreement for the in vivo measurement of tear film thickness after a half blink. By examining the flux of the fluid, we provide an explanation of this assumption. We also investigate the temperature dynamics both at the ocular surface and inside the simulated anterior chamber. Our simulation results suggest that the ocular surface temperature readjusts rapidly to normal temperature distribution after partial blinks. PMID:25635242

  2. The EpiOcular Eye Irritation Test (EIT) for hazard identification and labelling of eye irritating chemicals: protocol optimisation for solid materials and the results after extended shipment.

    PubMed

    Kaluzhny, Yulia; Kandárová, Helena; Handa, Yuki; DeLuca, Jane; Truong, Thoa; Hunter, Amy; Kearney, Paul; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2015-05-01

    The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances. 2015 FRAME.

  3. The use of antimicrobial peptides in ophthalmology: an experimental study in corneal preservation and the management of bacterial keratitis.

    PubMed Central

    Mannis, Mark J

    2002-01-01

    PURPOSE: Bacterial keratitis is an ocular infection with the potential to cause significant visual impairment. Increasing patterns of antibiotic resistance have necessitated the development of new antimicrobial agents for use in bacterial keratitis and other serious ocular infections. With a view to exploring the use of novel antimicrobial peptides in the management of ocular infection, we performed a series of experiments using synthetic antimicrobial peptides designed for the eradication of common and serious ophthalmic pathogens. METHODS: Experiments were performed with three clinical ocular isolates--Pseudomonas aeruginosa, Staphylococcus aureus, and Staphylococcus epidermidis--in three experimental settings: (1) in vitro in a controlled system of 10 mM sodium phosphate buffer, (2) in vitro in modified chondroitin sulfate-based corneal preservation media (Optisol), and (3) in an in vivo animal model (rabbit) simulating bacterial keratitis. In all cases, outcomes were measured by quantitative microbiological techniques. RESULTS: The candidate peptides (CCI A, B, and C and COL-1) produced a total reduction of the test pathogens in phosphate buffered saline. In modified Optisol, the peptides were effective against S epidermidis at all temperatures, demonstrated augmented activity at 23 degrees C against the gram-positive organisms, but were ineffective against P aeruginosa. The addition of EDTA to the medium augmented the killing of P aeruginosa but made no difference in the reduction of gram-positive organisms. In an in vivo rabbit model of Pseudomonas keratitis, COL-1 demonstrated neither clinical nor microbicidal efficacy and appeared to have a very narrow dosage range, outside of which it appeared to be toxic to the ocular surface. CONCLUSION: Our data indicate that the antimicrobial peptides we tested were effective in vitro but not in vivo. In an age of increasing antibiotic resistance, antimicrobial peptides, developed over millions of years as innate defense mechanisms by plants and animals, may have significant potential for development as topical agents for the management of severe bacterial keratitis. However, modifications of the peptides, the drug delivery systems, or both, will be necessary for effective clinical application. PMID:12545697

  4. Surface Modified Multifunctional and Stimuli Responsive Nanoparticles for Drug Targeting: Current Status and Uses

    PubMed Central

    Siafaka, Panoraia I.; Üstündağ Okur, Neslihan; Karavas, Evangelos; Bikiaris, Dimitrios N.

    2016-01-01

    Nanocarriers, due to their unique features, are of increased interest among researchers working with pharmaceutical formulations. Polymeric nanoparticles and nanocapsules, involving non-toxic biodegradable polymers, liposomes, solid lipid nanoparticles, and inorganic–organic nanomaterials, are among the most used carriers for drugs for a broad spectrum of targeted diseases. In fact, oral, injectable, transdermal-dermal and ocular formulations mainly consist of the aforementioned nanomaterials demonstrating promising characteristics such as long circulation, specific targeting, high drug loading capacity, enhanced intracellular penetration, and so on. Over the last decade, huge advances in the development of novel, safer and less toxic nanocarriers with amended properties have been made. In addition, multifunctional nanocarriers combining chemical substances, vitamins and peptides via coupling chemistry, inorganic particles coated by biocompatible materials seem to play a key role considering that functionalization can enhance characteristics such as biocompatibility, targetability, environmental friendliness, and intracellular penetration while also have limited side effects. This review aims to summarize the “state of the art” of drug delivery carriers in nanosize, paying attention to their surface functionalization with ligands and other small or polymeric compounds so as to upgrade active and passive targeting, different release patterns as well as cell targeting and stimuli responsibility. Lastly, future aspects and potential uses of nanoparticulated drug systems are outlined. PMID:27589733

  5. Detection of sialomucin complex (MUC4) in human ocular surface epithelium and tear fluid.

    PubMed

    Pflugfelder, S C; Liu, Z; Monroy, D; Li, D Q; Carvajal, M E; Price-Schiavi, S A; Idris, N; Solomon, A; Perez, A; Carraway, K L

    2000-05-01

    To evaluate human ocular surface epithelium and tear fluid for the presence of sialomucin complex (MUC4), a high-molecular-weight heterodimeric glycoprotein composed of mucin (ASGP-1) and transmembrane (ASGP-2) subunits. Reverse transcription-polymerase chain reaction (RT-PCR) and Northern blot analysis assays were used to identify sialomucin complex RNA in ocular surface epithelia. Immunoprecipitation and immunoblot analysis were used to identify immunoreactive species in human tears and in the corneal and conjunctival epithelia using antibodies specific for carbohydrate and peptide epitopes on the sialomucin complex subunits. Immunofluorescence staining was used to detect sialomucin complex in frozen sections and impression cytology specimens of human cornea and conjunctival epithelia. ASGP-1- and ASGP-2-specific sequences were amplified from RNA extracted from both conjunctival and corneal epithelial biopsies by RT-PCR. Sialomucin complex transcripts were also detected in these tissues by Northern blot analysis, with a greater level of RNA detected in the peripheral than the central corneal epithelium. Sialomucin complex was immunoprecipitated from tear fluid samples and both corneal and conjunctival epithelia and detected by immunoblot analysis with specific anti-ASGP-1 and anti-ASGP-2 antibodies. The ASGP-1 peptide antibody HA-1 stained the full thickness of the corneal and conjunctival epithelia. In contrast, antibody 15H10, which reacts against a carbohydrate epitope on ASGP-1, stained only the superficial epithelial layers of these tissues. No staining was observed in the conjunctival goblet cells. Sialomucin complex was originally identified in rat mammary adenocarcinoma cells and has recently been shown to be produced by the ocular surface epithelia of rats. Furthermore, it has been identified as the rat homologue of human MUC4 mucin. The present studies show that it is expressed in the stratified epithelium covering the surface of the human eye and is present in human tear fluid. Expression of a carbohydrate-dependent epitope on the mucin subunit (ASGP-1) of sialomucin complex occurs in a differentiation-dependent fashion. Sialomucin complex joins MUC1 as another membrane mucin produced by the human ocular surface epithelia but is also found in the tear fluid, presumably in a soluble form, as found on the rat ocular surface.

  6. Lacritin and other new proteins of the lacrimal functional unit.

    PubMed

    McKown, Robert L; Wang, Ningning; Raab, Ronald W; Karnati, Roy; Zhang, Yinghui; Williams, Patricia B; Laurie, Gordon W

    2009-05-01

    The lacrimal functional unit (LFU) is defined by the 2007 International Dry Eye WorkShop as 'an integrated system comprising the lacrimal glands, ocular surface (cornea, conjunctiva and meibomian glands) and lids, and the sensory and motor nerves that connect them'. The LFU maintains a healthy ocular surface primarily through a properly functioning tear film that provides protection, lubrication, and an environment for corneal epithelial cell renewal. LFU cells express thousands of proteins. Over 200 new LFU proteins have been discovered in the last decade. Lacritin is a new LFU-specific growth factor in human tears that flows through ducts to target corneal epithelial cells on the ocular surface. When applied topically in rabbits, lacritin appears to increase the volume of basal tear secretion. Lacritin is one of only a handful of tear proteins preliminarily reported to be downregulated in blepharitis and in two dry eye syndromes. Computational analysis predicts an ordered C-terminal domain that binds the corneal epithelial cell surface proteoglycan syndecan-1 (SDC1) and is required for lacritin's low nanomolar mitogenic activity. The lacritin-binding site on the N-terminus of SDC1 is exposed by heparanase. Heparanase is constitutively expressed by the corneal epithelium and appears to be a normal constituent of tears. Binding triggers rapid signaling to downstream NFAT and mTOR. A wealth of other new proteins, originally designated as hypothetical when first identified by genomic sequencing, are expressed by the human LFU including: ALS2CL, ARHGEF19, KIAA1109, PLXNA1, POLG, WIPI1 and ZMIZ2. Their demonstrated or implied roles in human genetic disease or basic cellular functions are fuel for new investigation. Addressing topical areas in ocular surface physiology with new LFU proteins may reveal interesting new biological mechanisms and help get to the heart of ocular surface dysfunction.

  7. Ocular surface epithelium induces expression of human mucosal lymphocyte antigen (HML-1) on peripheral blood lymphocytes

    PubMed Central

    Gomes, J A P; Dua, H S; Rizzo, L V; Nishi, M; Joseph, A; Donoso, L A

    2004-01-01

    Background/aims: Peripheral blood CD8+ lymphocytes that home to mucosal surfaces express the human mucosal lymphocyte antigen (HML-1). At mucosal surfaces, including the ocular surface, only intraepithelial CD8+ lymphocytes express HML-1. These lymphocytes are retained in the intraepithelial compartment by virtue of the interaction between HML-1 and its natural ligand, E-cadherin, which is expressed on epithelial cells. The purpose of this study was to determine whether ocular surface epithelial cells (ocular mucosa) could induce the expression of human mucosal lymphocyte antigen on peripheral blood lymphocytes. Methods: Human corneal and conjunctival epithelial cells were co-cultured with peripheral blood lymphocytes. Both non-activated and activated lymphocytes were used in the experiments. After 7 days of incubation, lymphocytes were recovered and analysed for the antigens CD8/HML-1, CD4/HML-1, CD3/CD8, CD3/CD4, CD3/CD25, CD8/CD25, and CD4/CD25 by flowcytometry. Results: Significant statistical differences were observed in the CD8/HML-1 expression when conjunctival epithelial cells were co-cultured with non-activated and activated lymphocytes (p = 0.04 for each) and when corneal epithelial cells were co-cultured with non-activated lymphocytes (p = 0.03). Significant statistical difference in CD4/HML-1 expression was observed only when conjunctival epithelial cells were co-cultured with activated lymphocytes (p = 0.02). Conclusion: Ocular surface epithelial cells can induce the expression of human mucosal lymphocyte antigen on CD8+ (and to some extent on CD4+) lymphocytes. This may allow the retention of CD8+ and CD4+ lymphocytes within the epithelial compartment of the conjunctiva and play a part in mucosal homing of lymphocytes. PMID:14736792

  8. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography

    DTIC Science & Technology

    2010-05-01

    Nontraumatic RBH occurs rarely and has been associated with arteriovenous malformations,1 following thrombolysis,2 Type IV Ehlers - Danlos Syndrome ,3...infarction. N Engl J Med. 2007; 357:1448-9. 3. Shaikh S, Braun M, Eliason J. Spontaneous retrobulbar hemorrhage in type IV Ehlers - Danlos syndrome . Am J...compartment syndrome . DISCUSSION We believe this is the first case report of a nontraumatic RBH associated with warfarin toxicity. Our patient also had

  9. Effect of 0.3% Hydroxypropyl Methylcellulose/Dextran Versus 0.18% Sodium Hyaluronate in the Treatment of Ocular Surface Disease in Glaucoma Patients: A Randomized, Double-Blind, and Controlled Study.

    PubMed

    Prabhasawat, Pinnita; Ruangvaravate, Ngamkae; Tesavibul, Nattaporn; Thewthong, Maneerat

    2015-01-01

    To compare the efficacy and safety of 0.3% hydroxypropyl methylcellulose/dextran (HPMC/dextran) and 0.18% sodium hyaluronate (SH) in the treatment of ocular surface disease in patients using antiglaucoma drugs containing preservatives. This was a double-blind, randomized, parallel-group study in 70 glaucoma patients with Ocular Surface Disease Index (OSDI) score greater than 20 points and/or presence of ocular signs. Patients were randomized to receive either preservative-free 0.3% HPMC/dextran (n=35) or preservative-free 0.18% SH (n=35). Treatment was 1 drop in each eye, 4 times a day. Data were collected at baseline, at day 7 and day 28. The groups were homogeneous at baseline. At day 28, both treatments showed significant improvements (P<0.05) in the mean OSDI score, lid skin and lid margin inflammation, conjunctival injection, and expressibility of meibomian glands, corneal staining score, fluorescein tear breakup time (FBUT), and Schirmer I test. However, the mean OSDI score, lid margin inflammation and conjunctival injection showed significant improvements (P<0.05) in the SH group at days 7 and 28, compared to the HPMC/dextran group. FBUT and the Schirmer I test also showed significant improvements (P<0.05) in the SH group compared to the HPMC/dextran group, at day 28. No adverse reactions were observed in either group. Preservative-free artificial tear, 0.3% HPMC/dextran, and 0.18% SH, caused a significant relief of the ocular surface disease in glaucoma patients. However, 0.18% SH led to a greater improvement in ocular signs and symptoms than 0.3% HPMC/dextran.

  10. Rebamipide protects against glaucoma eyedrop-induced ocular surface disorders in rabbits

    PubMed Central

    Kawaguchi, Ichiro; Higashide, Tomomi; Takeji, Yasuhiro; Sakurai, Kazushi; Kawaguchi, Chiaki; Sugiyama, Kazuhisa

    2017-01-01

    Purpose This study aimed to determine if rebamipide eyedrops can improve ocular surface damage caused by the use of glaucoma eyedrops. Methods Female Kbl:Dutch rabbits were used to evaluate glaucoma eyedrop-induced ocular surface damage; one eye of each rabbit was untreated and the other was administered glaucoma eyedrops for 30 days. To evaluate the effects of rebamipide on ocular surface damage, one eye of each rabbit was administered vehicle-treated glaucoma eyedrops and the other was administered rebamipide-treated glaucoma eyedrops for 30 days. Corneal and conjunctival epithelial damage was evaluated using fluorescein and rose bengal staining, respectively. Conjunctival inflammation was observed by light microscopy with hematoxylin-eosin staining. Dark cells (in which the corneal microvilli were damaged) were analyzed by scanning electron microscopy. Results There were no significant differences in fluorescein staining between the untreated and glaucoma eyedrop-treated groups; however, rose bengal staining and the number of inflammatory cells in the conjunctiva significantly increased after glaucoma eyedrop treatment. There was a four-fold increase in the number of dark cells in the glaucoma eyedrop-treated group compared to untreated. In contrast, in the conjunctiva of the rebamipide-treated glaucoma eyedrop group, rose bengal staining scores, the number of inflammatory cells, and the number of dark cells were decreased compared to the vehicle-treated glaucoma eyedrop group. Conclusions Results from our in vivo rabbit study demonstrated that short-term use of glaucoma eyedrops induces corneal epithelium disorders at the cellular level, but that simultaneous use of rebamipide has the potential to protect and repair the ocular surface. PMID:29049370

  11. Rebamipide protects against glaucoma eyedrop-induced ocular surface disorders in rabbits.

    PubMed

    Kawaguchi, Ichiro; Kobayashi, Akira; Higashide, Tomomi; Takeji, Yasuhiro; Sakurai, Kazushi; Kawaguchi, Chiaki; Sugiyama, Kazuhisa

    2017-01-01

    This study aimed to determine if rebamipide eyedrops can improve ocular surface damage caused by the use of glaucoma eyedrops. Female Kbl:Dutch rabbits were used to evaluate glaucoma eyedrop-induced ocular surface damage; one eye of each rabbit was untreated and the other was administered glaucoma eyedrops for 30 days. To evaluate the effects of rebamipide on ocular surface damage, one eye of each rabbit was administered vehicle-treated glaucoma eyedrops and the other was administered rebamipide-treated glaucoma eyedrops for 30 days. Corneal and conjunctival epithelial damage was evaluated using fluorescein and rose bengal staining, respectively. Conjunctival inflammation was observed by light microscopy with hematoxylin-eosin staining. Dark cells (in which the corneal microvilli were damaged) were analyzed by scanning electron microscopy. There were no significant differences in fluorescein staining between the untreated and glaucoma eyedrop-treated groups; however, rose bengal staining and the number of inflammatory cells in the conjunctiva significantly increased after glaucoma eyedrop treatment. There was a four-fold increase in the number of dark cells in the glaucoma eyedrop-treated group compared to untreated. In contrast, in the conjunctiva of the rebamipide-treated glaucoma eyedrop group, rose bengal staining scores, the number of inflammatory cells, and the number of dark cells were decreased compared to the vehicle-treated glaucoma eyedrop group. Results from our in vivo rabbit study demonstrated that short-term use of glaucoma eyedrops induces corneal epithelium disorders at the cellular level, but that simultaneous use of rebamipide has the potential to protect and repair the ocular surface.

  12. Tear Osmolarity and Correlation With Ocular Surface Parameters in Patients With Dry Eye.

    PubMed

    Mathews, Priya M; Karakus, Sezen; Agrawal, Devika; Hindman, Holly B; Ramulu, Pradeep Y; Akpek, Esen K

    2017-11-01

    To analyze the distribution of tear film osmolarity in patients with dry eye and its association with other ocular surface parameters. Tear osmolarity and other quantitative dry eye parameters were obtained from patients with 1) clinically significant dry eye (significant symptoms and ocular surface staining, n = 131), 2) symptoms-only dry eye (significant symptoms but no significant ocular surface staining, n = 52), and 3) controls (no significant symptoms or staining, n = 42). Tear osmolarity varied significantly across groups (P = 0.01), with patients with clinically significant dry eye having the highest tear osmolarity (312.0 ± 16.9 mOsm/L), control patients having the lowest tear osmolarity (305.6 ± 9.7 mOsm/L), and patients with symptoms-only dry eye falling in between (307.4 ± 5.6 mOsm/L). Patients with clinically significant dry eye also tended to have a greater intereye difference in osmolarity (12.0 ± 13.4) than did the individuals with symptoms-only dry eye (9.1 ± 12.4) and controls (9.0 ± 7.4) (P = 0.06). In multivariable regression models, higher tear osmolarity was associated with higher Ocular Surface Disease Index, discomfort subscore (P = 0.02), and higher corneal and conjunctival staining scores (P < 0.01 for both). Worse eye tear osmolarity was not correlated with the corresponding tear film breakup time or Schirmer test (P > 0.05 for both). Individuals with symptomatic dry eye that is not yet clinically significant seem to have higher and more variable osmolarity measurements than controls, potentially indicating that changes in osmolarity precede clinical findings.

  13. [Optimization of benzalkonium chloride concentration in 0.0015% tafluprost ophthalmic solution from the points of ocular surface safety and preservative efficacy].

    PubMed

    Asada, Hiroyuki; Takaoka-Shichijo, Yuko; Nakamura, Masatsugu; Kimura, Akio

    2010-06-01

    Optimization of benzalkonium chloride (alkyl dimethylbenzylammonium chloride: BAK) concentration as preservative in 0.0015% tafluprost ophthalmic solution (Tapros 0.0015% ophthalmic solution), an anti-glaucoma medicine, was examined from the points of ocular surface safety and preservative efficacy. BAKC(12), which is dodecyl dimethylbenzylammonium chloride, and BAKmix, which is the mixture of dodecyl, tetradecyl and hexadecyl dimethylbenzylammonium chloride were used in this study. The effects of BAKC(12) concentrations and the BAK types, BAKC(12) and BAKmix, in tafluprost ophthalmic solution on ocular surface safety were evaluated using the in vitro SV 40-immobilized human corneal epithelium cell line (HCE-T). Following treatments of Tafluprost ophthalmic solutions with BAKC(12), its concentration dependency was observed on cell viability of HCE-T. The cell viability of HCE-T after treatment of these solutions with 0.001% to 0.003% BAKC(12) for 5 minutes were the same level as that after treatment of the solution without BAK. Tafluprost ophthalmic solution with 0.01% BAKC(12) was safer for the ocular surface than the same solution with 0.01% BAKmix. Preservatives-effectiveness tests of tafluprost ophthalmic solutions with various concentrations of BAKC(12) were performed according to the Japanese Pharmacopoeia (JP), and solutions with more than 0.0005% BAKC(12) conformed to JP criteria. It was concluded that 0.0005% to 0.003% of BAKC(12) in tafluprost ophthalmic solution was optimal, namely, well-balanced from the points of ocular surface safety and preservative efficacy.

  14. Anterior Corneal, Posterior Corneal, and Lenticular Contributions to Ocular Aberrations.

    PubMed

    Atchison, David A; Suheimat, Marwan; Mathur, Ankit; Lister, Lucas J; Rozema, Jos

    2016-10-01

    To determine the corneal surfaces and lens contributions to ocular aberrations. There were 61 healthy participants with ages ranging from 20 to 55 years and refractions -8.25 diopters (D) to +3.25 D. Anterior and posterior corneal topographies were obtained with an Oculus Pentacam, and ocular aberrations were obtained with an iTrace aberrometer. Raytracing through models of corneas provided total corneal and surface component aberrations for 5-mm-diameter pupils. Lenticular contributions were given as differences between ocular and corneal aberrations. Theoretical raytracing investigated influence of object distance on aberrations. Apart from defocus, the highest aberration coefficients were horizontal astigmatism, horizontal coma, and spherical aberration. Most correlations between lenticular and ocular parameters were positive and significant, with compensation of total corneal aberrations by lenticular aberrations for 5/12 coefficients. Anterior corneal aberrations were approximately three times higher than posterior corneal aberrations and usually had opposite signs. Corneal topographic centers were displaced from aberrometer pupil centers by 0.32 ± 0.19 mm nasally and 0.02 ± 0.16 mm inferiorly; disregarding corneal decentration relative to pupil center was significant for oblique astigmatism, horizontal coma, and horizontal trefoil. An object at infinity, rather than at the image in the anterior cornea, gave incorrect aberration estimates of the posterior cornea. Corneal and lenticular aberration magnitudes are similar, and aberrations of the anterior corneal surface are approximately three times those of the posterior surface. Corneal decentration relative to pupil center has significant effects on oblique astigmatism, horizontal coma, and horizontal trefoil. When estimating component aberrations, it is important to use correct object/image conjugates and heights at surfaces.

  15. Long-term outcomes after adjunctive topical 5-flurouracil or mitomycin C for the treatment of surgically excised, localized ocular surface squamous neoplasia.

    PubMed

    Bahrami, Bobak; Greenwell, Timothy; Muecke, James S

    2014-01-01

    To report rates of recurrence and complications of localized ocular surface squamous neoplasia treated with 5-fluorouracil or mitomycin C as adjunctive treatment to surgical excision. Long-term follow up of two prospective, non-comparative interventional case series. One hundred fifty-three eyes with histologically confirmed localized, non-invasive ocular surface squamous neoplasia. 89 eyes were treated with adjuvant 5-fluorouracil and 64 eyes were treated with adjuvant mitomycin C. Following surgical excision±cryotherapy patients received topical 5-fluorouracil 1% four times daily for two weeks or topical mitomycin C 0.04% four times daily for two to three 1-week cycles. Ocular surface squamous neoplasia recurrence, complications of therapy and compliance. Median follow up was 33.6 (range 12-84) months and 57.9 (range 12-160) months in 5-fluorouracil and mitomycin C groups, respectively. There was one recurrence in the 5-fluorouracil group and no recurrences in the mitomycin C group. Side-effects occurred in 69% of 5-fluorouracil patients and 41% of mitomycin C patients. Five patients (6%) required intervention for treatment-related side-effects in the 5-fluorouracil group versus 11 (17%) in the mitomycin C group. No vision-threatening complications were noted. Long-term recurrence of localised ocular surface squamous neoplasia is rare when topical 5-fluorouracil or mitomycin C are used as adjunctive treatment to surgical excision. While side-effects are common, the majority are transient and rarely limit compliance. © 2013 Royal Australian and New Zealand College of Ophthalmologists.

  16. Topically applied 1% voriconazole induces dysplastic changes on the ocular surface: animal study.

    PubMed

    Arikan, Gul; Karatas, Ezgi; Lebe, Banu; Ayhan, Ziya; Utine, Canan Asli; Kutsoylu, Oya Eren; Gunenc, Uzeyir; Yilmaz, Osman

    2018-04-26

    To identify the risk of inducing ocular surface dysplasia following topical administration of 1% voriconazole eye drop. Fourteen noninflamed healthy eyes of 14 white adult New Zealand rabbits were included in the study. The rabbits were randomly divided into two groups comprised of 7 rabbits each. Group 1 received topical 1% voriconazole and Group 2 received topical saline as the control group. In all animals, right eye was selected for the study. In Group 1 (Voriconazole Group), single drop of voriconazole was instilled every 10 min consecutively for 17 times a day for 60 days. In Group 2 (Control Group), single drop of saline was instilled every 10 min consecutively for 17 times a day for 60 days. At two months, animals were sacrificed and study eyes were enucleated with the eyelids. The specimens were stained with hematoxylin-eosin and histopathologic changes in cornea, bulbar and palpebral conjunctiva were evaluated under light microscope. There were no macroscopically visible lesions on the ocular surface of any rabbits. Histopathological evaluation showed mild to moderate dysplasia localized mainly in the limbus and extending to the adjacent cornea and bulbar conjunctiva in all rabbits in Voriconazole Group. Severe dysplasia or carcinoma in situ was not observed. In the Control Group, dysplasia was not observed, at all. This animal study provides a possible relationship between topically administered 1% voriconazole and ocular surface dysplasia. We recommend ophthalmologists to be aware of the risk of ocular surface dysplasia in patients received voriconazole eye drop.

  17. The Lunar Environment: Determining the Health Effects of Exposure to Moon Dusts

    NASA Technical Reports Server (NTRS)

    Khan-Mayberry, Noreen

    2007-01-01

    The Earth s moon presents a hostile environment in which to live and work. There is no atmosphere to protect its surface from the ravages of solar wind and micrometeorite impacts. As a result, the moon s surface is covered with a thin layer of fine, charged, reactive dust capable of entering habitats and vehicle compartments, where it can result in crewmember health problems. During the Apollo missions, lunar dusts were introduced into the crew vehicle, resulting in direct exposure and occasional reports of respiratory, dermal and ocular irritation. In order to study the toxicological effects of lunar dust, NASA formed the Lunar Airborne Dust Toxicity Advisory Group (LADTAG). This interdisciplinary group is comprised of leading experts in space toxicology, lunar geology, space medicine and biomedical research. LADTAG has demonstrated that lunar soil contains several types of reactive dusts, including an extremely fine respirable component. These dusts have highly reactive surfaces in the lunar environment; the grains contain surface coatings which are generated by vapor phases formed by hypervelocity impact of micrometeorites. This unique class of dusts has surface properties that are unlike any Earth based analog. These distinctive properties are why lunar dusts are of great toxicological interest. Understanding how these reactive components behave "biochemically" in a moisture-rich pulmonary environment will aid in determining how toxic these particles are to humans. The data obtained from toxicological examination of lunar dusts will determine the human risk criteria for lunar dust exposure and produce a lunar health standard. LADTAG s analysis of lunar dusts and lunar dust simulants will include detailed lunar particle characterizations, determining the properties of particle activation, reactivation of lunar dust, the process of dust passivation and discerning the pathology of lunar dust exposure via inhalation, intratracheal instillation, cell culture exposure, dermal exposure and ocular exposure. The resulting health standard will be time-based and will vary by the duration and type of exposure. It may also be necessary to set multiple standards for different types of lunar dust, as well as for dust in its activated form vs. aged & passivated dust. This standard, set to protect the health of our robust astronaut crews, will not only impact NASA medical operations, but engineering designs as well. The data from our multidisciplinary research are vital in developing remediation devices and environmental monitors. Ultimately, the engineering and safety groups will design and develop countermeasures for space vehicles, suits, rovers and habitats that will be sustained within the limits of the health standard.

  18. Relevance of Lipid-Based Products in the Management of Dry Eye Disease.

    PubMed

    Garrigue, Jean-Sébastien; Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M; Tong, Louis

    2017-11-01

    Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air-water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed.

  19. Thermal fluctuation based study of aqueous deficient dry eyes by non-invasive thermal imaging.

    PubMed

    Azharuddin, Mohammad; Bera, Sumanta Kr; Datta, Himadri; Dasgupta, Anjan Kr

    2014-03-01

    In this paper we have studied the thermal fluctuation patterns occurring at the ocular surface of the left and right eyes for aqueous deficient dry eye (ADDE) patients and control subjects by thermal imaging. We conducted our experiment on 42 patients (84 eyes) with aqueous deficient dry eyes and compared with 36 healthy volunteers (72 eyes) without any history of ocular surface disorder. Schirmer's test, Tear Break-up Time, tear Meniscus height and fluorescein staining tests were conducted. Ocular surface temperature measurement was done, using an FL-IR thermal camera and thermal fluctuation in left and right eyes was calculated and analyzed using MATLAB. The time series containing the sum of squares of the temperature fluctuation on the ocular surface were compared for aqueous deficient dry eye and control subjects. Significant statistical difference between the fluctuation patterns for control and ADDE was observed (p < 0.001 at 95% confidence interval). Thermal fluctuations in left and right eyes are significantly correlated in controls but not in ADDE subjects. The possible origin of such correlation in control and lack of correlation in the ADDE subjects is discussed in the text. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Evaluation of Dry Eye and Meibomian Gland Dysfunction in Teenagers with Myopia through Noninvasive Keratograph

    PubMed Central

    Wang, Xiu; Lu, Xiaoxiao; Yang, Jun; Wei, Ruihua; Yang, Liyuan; Zhao, Shaozhen; Wang, Xilian

    2016-01-01

    Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7–18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dry eye standard, and their ocular surfaces and meibomian gland conditions were evaluated. Results. The tear meniscus heights of the dry eye and normal groups were in normal range. Corneal fluorescein scores were significantly higher whereas noninvasive break-up time was dramatically shorter in the dry eye group than in the normal group. All three meibomian gland dysfunction parameters (i.e., meibomian gland orifice scores, meibomian gland secretion scores, and meibomian gland dropout scores) of the dry eye group were significantly higher than those of the normal group (P < 0.0001). Conclusions. The prevalence of dry eye in myopic teenagers is 18.95%. Meibomian gland dysfunction plays an important role in dry eye in myopic teenagers. The Keratograph 5M appears to provide an effective noninvasive method for assessing ocular surface situation of myopic teenagers. PMID:26881059

  1. Changes in the tear film and ocular surface from dry eye syndrome.

    PubMed

    Johnson, Michael E; Murphy, Paul J

    2004-07-01

    Dry eye syndrome (DES) refers to a spectrum of ocular surface diseases with diverse and frequently multiple aetiologies. The common feature of the various manifestations of DES is an abnormal tear film. Tear film abnormalities associated with DES are tear deficiency, owing to insufficient supply or excessive loss, and anomalous tear composition. These categorizations are artificial, as in reality both often coexist. DES disrupts the homeostasis of the tear film with its adjacent structures, and adversely affects its ability to perform essential functions such as supporting the ocular surface epithelium and preventing microbial invasion. In addition, whatever the initial trigger, moderate and severe DES is characterized by ocular surface inflammation, which in turn becomes the cause and consequence of cell damage, creating a self-perpetuating cycle of deterioration. Progress has been made in our understanding of the aetiology and pathogenesis of DES, and these advances have encouraged a proliferation of therapeutic options. This article aims to amalgamate prevailing ideas of DES development, and to assist in that, relevant aspects of the structure, function, and production of the tear film are reviewed. Additionally, a synopsis of therapeutic strategies for DES is presented, detailing treatments currently available, and those in development.

  2. Ultra High-Resolution Anterior Segment Optical Coherence Tomography in the Diagnosis and Management of Ocular Surface Squamous Neoplasia

    PubMed Central

    Thomas, Benjamin J.; Galor, Anat; Nanji, Afshan A.; Sayyad, Fouad El; Wang, Jianhua; Dubovy, Sander R.; Joag, Madhura G.; Karp, Carol L.

    2014-01-01

    The development of optical coherence tomography (OCT) technology has helped to usher in a new era of in vivo diagnostic imaging of the eye. The utilization of OCT for imaging of the anterior segment and ocular surface has evolved from time-domain devices to spectral-domain devices with greater penetrance and resolution, providing novel images of anterior segment pathology to assist in diagnosis and management of disease. Ocular surface squamous neoplasia (OSSN) is one such pathology that has proven demonstrable by certain anterior segment OCT machines, specifically the newer devices capable of performing ultra high-resolution OCT (UHR-OCT). Distinctive features of OSSN on high resolution OCT allow for diagnosis and differentiation from other ocular surface pathologies. Subtle findings on these images help to characterize the OSSN lesions beyond what is apparent with the clinical examination, providing guidance for clinical management. The purpose of this review is to examine the published literature on the utilization of UHR-OCT for the diagnosis and management of OSSN, as well as to report novel uses of this technology and potential directions for its future development. PMID:24439046

  3. Improved impression cytology techniques for the immunopathological diagnosis of superficial viral infections

    PubMed Central

    Thiel, M; Bossart, W; Bernauer, W

    1997-01-01

    BACKGROUND—For epidemiological and therapeutic reasons early diagnosis of superficial viral infections is crucial. Conventional microbiological techniques are expensive, time consuming, and not sufficiently sensitive. In this study impression cytology techniques were evaluated to analyse their diagnostic potential in viral infections of the ocular surface.
METHOD—A Biopore membrane device instead of the original impression cytology technique was used to allow better quality and handling of the specimens. The impressions were processed, using monoclonal antibodies and immunoperoxidase or immunofluorescence techniques to assess the presence of herpes simplex virus, varicella zoster virus, or adenovirus antigens. Ocular surface specimens from healthy individuals (n=10) and from patients with suspected viral surface disease (n=19) were studied. Infected and non-infected cell cultures served as controls.
RESULTS—This modified technique of impression cytology allowed the collection of large conjunctival and corneal epithelial cell layers with excellent morphology. Immunocytological staining of these samples provided diagnostic results for all three viruses in patients with viral surface disease.
CONCLUSIONS—The use of Biopore membrane devices for the collection of ocular surface epithelia offers new diagnostic possibilities for external eye diseases. Immunopathological methods that are applied directly on these membrane devices can provide virological results within 1-4 hours. This contributes considerably to the clinical management of patients with infectious diseases of the ocular surface.

 PMID:9505824

  4. Tear film aberration dynamics and vision-related quality of life in patients with dry eye disease.

    PubMed

    Denoyer, Alexandre; Rabut, Ghislaine; Baudouin, Christophe

    2012-09-01

    Corneal and ocular wavefront aberrations were recorded together with clinical examination results and patient-reported vision-related quality-of-life evaluation results to define the relevance of dynamic optical analysis of the eye in dry eye disease (DED). Prospective and comparative clinical study. Forty DED patients and 40 age- and gender-matched control subjects. Serial measurements of ocular and corneal higher-order aberrations (HOAs) after blink were performed for 10 seconds using the KR-1 aberrometer (Topcon, Clichy, France). Vision-related health-targeted quality of life was evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. The clinical examination included tear film assessment (tear film break-up time and Schirmer I test), ocular surface damage assessment with the Oxford and van Bijsterveld indexes, and Meibomian dysfunction grading. Tear osmolarity also was measured. The time course of HOAs and modulation transfer function (MTF) was compared between groups and was analyzed in comparison with the OSDI and clinical data in DED patients. The root mean square of ocular and corneal total HOAs, particularly third-order aberrations, significantly increased over the 10-second period in DED patients, whereas no change occurred in controls. Analysis of MTF revealed progressive degradation of ocular optical quality resulting from loss of contrast at intermediate and high spatial frequencies in DED patients compared with controls. The progression index for corneal HOAs was correlated with the subjective index of patient-reported visual outcomes and with objective clinical findings of tear film and ocular surface damage. Objective measurement of the time course of HOAs may constitute a new single instrument to evaluate and manage patients with DED because it reliably reflects the completeness of the disease. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  5. Eye cosmetic usage and associated ocular comfort.

    PubMed

    Ng, Alison; Evans, Katharine; North, Rachel; Purslow, Christine

    2012-11-01

    Eye cosmetics usage is commonplace and whilst some products such as eyeliner are applied with close proximity to the ocular surface, there is little knowledge of the short- and long-term ocular effects of eye cosmetic formulations. This study aimed to investigate the use of eye cosmetics and identify any relationships between ocular comfort and cosmetic usage. Results were collated from an online survey comprising 23 questions that recorded demographics, Ocular Surface Disease Index (OSDI) score, extent and range of eye cosmetic use and perceived comfort differences with and without eye cosmetics. The 1360 female respondents (median age 25, interquartile range 20-34 years) completed the survey; 83% reported using eye cosmetics regularly (≥ 3 times per week) with mascara being most commonly used. Fifty three per cent used at least three different eye cosmetics products regularly. OSDI scores of cosmetics users were similar to non-users (p = 0.083), but perceived comfort was greater when cosmetics were not used (p < 0.001). In occasional cosmetics users (use of products < 3 times per week), 65% reported a reduction in comfort when cosmetics were used. Median OSDI scores suggested a trend towards reduced comfort amongst eyeliner users (p = 0.07) although frequency and type of cosmetic products used did not appear to influence OSDI scores. This study shows the use of multiple eye cosmetics is extensive and associated with the perception of ocular discomfort. With such widespread use of these products, more research is required to assess the effect on the ocular surface and tear film, which may be underestimated. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.

  6. The Effect of Tear Supplementation with 0.15% Preservative-Free Zinc-Hyaluronate on Ocular Surface Sensations in Patients with Dry Eye.

    PubMed

    Perényi, Kristóf; Dienes, Lóránt; Kornafeld, Anna; Kovács, Balázs; Kiss, Huba J; Szepessy, Zsuzsanna; Nagy, Zoltán Z; Barsi, Árpád; Acosta, M Carmen; Gallar, Juana; Kovács, Illés

    To evaluate the effect of tear supplementation with preservative free 0.15% zinc-hyaluronate on ocular surface sensations and corneal sensitivity in dry eye patients. Ocular surface sensations were assessed using the ocular surface disease index (OSDI) questionnaire and by recording ocular sensations during forced blinking in parallel with noninvasive tear film breakup time measurement in 20 eyes of 20 dry eye patients. Corneal sensitivity thresholds to selective stimulation of corneal mechano-, thermal- and chemical receptors were measured using the Belmonte gas esthesiometer. All baseline measurements were repeated after 1 month of treatment with 0.15% zinc-hyaluronate. After 1 month, a significant decrease in mean OSDI score (from 35.66 ± 12.36 to 15.03 ± 11.22; P < 0.001) and a significant improvement in tear film breakup time (from 3.83 ± 0.80 to 8.67 ± 4.50 s; P < 0.001) was observed compared to baseline. Sensory responses during the interblink period also significantly decreased after 1 month (P < 0.004). Corneal sensitivity thresholds to mechanical stimulation (90.61 ± 20.35 vs. 103.92 ± 17.97 mL/min; P < 0.025) and chemical stimulation (33.21 ± 0.51 vs. 33.58% ± 0.44% CO 2 ; P < 0.025) significantly increased after 1 month, however sensitivity thresholds to thermal stimulation remained unchanged compared to baseline (P > 0.05). Prolonged use of 0.15% zinc-hyaluronate results in an improvement of tear film stability and a decrease of dry eye complaints. The decrease in corneal mechano-and polymodal receptor excitability suggests that zinc-hyaluronate helps to recover normal corneal sensitivity, and thus might have a beneficial additional effect on reducing ocular surface complaints in dry eye patients.

  7. Mucins in contact lens wear and dry eye conditions.

    PubMed

    Ramamoorthy, Padmapriya; Nichols, Jason J

    2008-08-01

    Ocular mucins are thought to play integral roles in ocular surface lubrication, anchoring of the aqueous, stabilizing the lipid components of the tear film, eliminating foreign bodies and pathogens, and with potential involvement in cell cycle mediation and apoptotic activity of ocular surface epithelia. Ocular mucins are of secreted and membrane-associated types. Secreted mucins may be of large gel-forming type or small soluble mucins (e.g., MUC5AC and MUC7). Membrane-associated mucins such as MUCs 1 and 4 are a major component of the glycocalyx. They are thought to render structural support to the microplicae and mediate epithelial cell cycle and apoptotic activity. The alterations in ocular mucins with contact lens wear are unclear. Recent work shows mucin expression may be up-regulated during the early years of contact lens wear, and with long-term lens wear, mucin expression may return to normal levels or sub-normal levels, although this is not well understood. Further, the polar nature of mucins may be associated with their affinity for contact lens surfaces making them a component of contact lens deposition. This has potential implications in the wettability and tolerability of contact lenses, and may be impacted by surface coatings, polymer characteristics, or care solutions. Conjunctival mucin gene expression and secretion may be deficient in several ocular surface disorders associated with dry eye. Deficiency and alterations in glycosylation characteristics of MUC5AC and MUC2 have been reported in both Sjögren and non-Sjögren dry eye types. Decreased binding of the membrane-associated mucin MUC16 to the conjunctival epithelium has been reported in Sjögren dry eye while MUC1 alterations have been reported in Sjögren and non-Sjögren dry eye states. In view of the mucin involvement in dry eye conditions, stimulation of mucus secretion pathways may hold promise in the pharmaceutical treatment of dry eye.

  8. Management of patients with ocular manifestations in vesiculobullous disorders affecting the mouth.

    PubMed

    Hansen, M S; Klefter, O N; Julian, H O; Lynge Pedersen, A M; Heegaard, S

    2017-10-01

    Pemphigoid and pemphigus diseases as well as Stevens-Johnson syndrome present as vesiculobullous disorders of the skin and may additionally involve both the oral cavity and the ocular surface. Ocular involvement ranges from mild irritation and dry eye disease to chronic conjunctivitis, symblepharon, eyelid malposition, ocular surface scarring and severe visual loss. In addition to diagnostic assessments, ophthalmologists must treat the dry eye and meibomian gland dysfunction components of these diseases using a stepladder approach, including eyelid hygiene and lubricants. Topical anti-inflammatory therapy is used to treat acute inflammatory exacerbations of the ocular surface, but it cannot prevent scarring alone. Intralesional antimetabolite therapy can cause regression of conjunctival pathology in selected cases. Hence, patients with vesiculobullous disorders should be managed by a multidisciplinary team representing ophthalmology, dermatology, otolaryngology, oral medicine and pathology, internal medicine and intensive care. Systemic treatments including corticosteroids, azathioprine, cyclophosphamide, cyclosporine and mycophenolate mofetil help control inflammation. Intravenous immunoglobulins, plasmapheresis and targeted antibody therapy can be used in selected, severe and treatment-resistant cases. Local surgical management may include debridement of pseudomembranes, lysis of symblepharon, amniotic and mucous membrane grafting as well as reconstructive procedures. Prospective, multicentre, international studies are recommended to further support evidence-based practice. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Infection and Replication of Influenza Virus at the Ocular Surface.

    PubMed

    Creager, Hannah M; Kumar, Amrita; Zeng, Hui; Maines, Taronna R; Tumpey, Terrence M; Belser, Jessica A

    2018-04-01

    Although influenza viruses typically cause respiratory tract disease, some viruses, particularly those with an H7 hemagglutinin, have been isolated from the eyes of conjunctivitis cases. Previous work has shown that isolates of multiple subtypes from both ocular and respiratory infections are capable of replication in human ex vivo ocular tissues and corneal or conjunctival cell monolayers, leaving the determinants of ocular tropism unclear. Here, we evaluated the effect of several variables on tropism for ocular cells cultured in vitro and examined the potential effect of the tear film on viral infectivity. All viruses tested were able to replicate in primary human corneal epithelial cell monolayers subjected to aerosol inoculation. The temperature at which cells were cultured postinoculation minimally affected infectivity. Replication efficiency, in contrast, was reduced at 33°C relative to that at 37°C, and this effect was slightly greater for the conjunctivitis isolates than for the respiratory ones. With the exception of a seasonal H3N2 virus, the subset of viruses studied in multilayer corneal tissue constructs also replicated productively after either aerosol or liquid inoculation. Human tears significantly inhibited the hemagglutination of both ocular and nonocular isolates, but the effect on viral infectivity was more variable, with tears reducing the infectivity of nonocular isolates more than ocular isolates. These data suggest that most influenza viruses may be capable of establishing infection if they reach the surface of ocular cells but that this is more likely for ocular-tropic viruses, as they are better able to maintain their infectivity during passage through the tear film. IMPORTANCE The potential spread of zoonotic influenza viruses to humans represents an important threat to public health. Unfortunately, despite the importance of cellular and tissue tropism to pathogenesis, determinants of influenza virus tropism have yet to be fully elucidated. Here, we sought to identify factors that limit the ability of most influenza viruses to cause ocular infection. Although ocular symptoms in humans caused by avian influenza viruses tend to be relatively mild, these infections are concerning due to the potential of the ocular surface to serve as a portal of entry for viruses that go on to establish respiratory infections. Furthermore, a better understanding of the factors that influence infection and replication in this noncanonical site may point toward novel determinants of tropism in the respiratory tract. This is a work of the U.S. Government and is not subject to copyright protection in the United States. Foreign copyrights may apply.

  10. Dangerous reef aquaristics: Palytoxin of a brown encrusting anemone causes toxic corneal reactions.

    PubMed

    Ruiz, Yasmin; Fuchs, Joan; Beuschel, Ralf; Tschopp, Markus; Goldblum, David

    2015-11-01

    Although frequently observed in domestic saltwater aquariums, literature on exposure to palytoxin (PTX) of encrusting anemones (Zoanthidea) kept in aquariums is rare. Handling these animals for propagation purposes or during cleaning work can lead to dermal, ocular or respiratory contact with the PTX generated by some Zoanthids. The present study describes a case of ocular exposure to liquid from a Zoanthid, which led to corneal ulcers. The patient also suffered from systemic symptoms of dyspnea and shivering and a suspected rhabdomyolysis, which required monitoring in the Intensive Care Unit. After symptomatic treatment provided insufficient results, the corneal ulcers improved with an amniotic membrane transplantation. A review of the literature regarding ocular exposures to this diverse order of Hexacorallia reveals that severe and systemic symptoms can develop with minimal contact. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Oculoplastic technique of connecting a glaucoma valve shunt to extraorbital locations in cases of severe glaucoma.

    PubMed

    Rubin, Peter A D; Chang, Eli; Bernardino, Carlo Roberto; Hatton, Mark P; Dohlman, Claes H

    2004-09-01

    To describe a technique for inserting glaucoma shunts to the sinuses or the lacrimal sac as a means of lowering intraocular pressure in patients with refractory glaucoma associated with severe ocular surface disease. Nineteen patients with severe ocular surface disease necessitating a keratoprosthesis and with intractable glaucoma underwent placement of a modified Ahmed shunt to direct aqueous in the maxillary or ethmoid sinus or lacrimal sac. Intraocular pressure is presently well controlled without glaucoma medications in two thirds of patients. None of the patients had endophthalmitis. Established oculoplastic surgery techniques may be used to redirect aqueous to extraorbital locations and effectively lower intraocular pressure in patients with severe ocular surface disease and refractory glaucoma. This procedure has not been associated with endophthalmitis.

  12. Recent developments on dry eye disease treatment compounds.

    PubMed

    Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus

    2014-01-01

    Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film.

  13. Xeroderma pigmentosum with bilateral ocular surface squamous neoplasia and review of the literature

    PubMed Central

    Kalamkar, Charudutt; Radke, Nishant; Mukherjee, Amrita; Radke, Snehal

    2016-01-01

    Xeroderma pigmentosum is a rare genetic disorder associated with various ocular malignancies. Here we report a single paediatric case of xeroderma pigmentosum with bilateral ocular surface squamous neoplasia (OSSN) presenting with diffuse lesion in one eye and a large mass in the other eye. Diffuse OSSN in one eye was treated with topical chemotherapy using mitomycin-C (0.04%) and the large OSSN in the other eye was treated with a combination of surgery and topical chemotherapy. Long-term follow-up and a multimodality treatment approach are necessary to identify and manage recurrences of OSSN in XP. PMID:27166000

  14. Periocular Reconstruction in Patients with Facial Paralysis.

    PubMed

    Joseph, Shannon S; Joseph, Andrew W; Douglas, Raymond S; Massry, Guy G

    2016-04-01

    Facial paralysis can result in serious ocular consequences. All patients with orbicularis oculi weakness in the setting of facial nerve injury should undergo a thorough ophthalmologic evaluation. The main goal of management in these patients is to protect the ocular surface and preserve visual function. Patients with expected recovery of facial nerve function may only require temporary and conservative measures to protect the ocular surface. Patients with prolonged or unlikely recovery of facial nerve function benefit from surgical rehabilitation of the periorbital complex. Current reconstructive procedures are most commonly intended to improve coverage of the eye but cannot restore blink. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Xeroderma pigmentosum with bilateral ocular surface squamous neoplasia and review of the literature.

    PubMed

    Kalamkar, Charudutt; Radke, Nishant; Mukherjee, Amrita; Radke, Snehal

    2016-05-10

    Xeroderma pigmentosum is a rare genetic disorder associated with various ocular malignancies. Here we report a single paediatric case of xeroderma pigmentosum with bilateral ocular surface squamous neoplasia (OSSN) presenting with diffuse lesion in one eye and a large mass in the other eye. Diffuse OSSN in one eye was treated with topical chemotherapy using mitomycin-C (0.04%) and the large OSSN in the other eye was treated with a combination of surgery and topical chemotherapy. Long-term follow-up and a multimodality treatment approach are necessary to identify and manage recurrences of OSSN in XP. 2016 BMJ Publishing Group Ltd.

  16. Exploring topical anti-glaucoma medication effects on the ocular surface in the context of the current understanding of dry eye.

    PubMed

    Wong, Aaron B C; Wang, Michael T M; Liu, Kevin; Prime, Zak J; Danesh-Meyer, Helen V; Craig, Jennifer P

    2018-07-01

    To assess tear film parameters, ocular surface characteristics, and dry eye symptomology in patients receiving topical anti-glaucoma medications. Thirty-three patients with a diagnosis of open angle glaucoma or ocular hypertension, receiving unilateral topical anti-glaucoma medication for at least 6 months, were recruited in a cross-sectional, investigator-masked, paired-eye comparison study. Tear film parameters, ocular surface characteristics, and dry eye symptomology of treated and fellow eyes were evaluated and compared. The mean ± SD age of the participants was 67 ± 12 years, and the mean ± SD treatment duration was 5.3 ± 4.4 years. Treated eyes had poorer non-invasive tear film breakup time (p = 0.03), tear film osmolarity (p = 0.04), bulbar conjunctival hyperaemia (p = 0.04), eyelid margin abnormality grade (p = 0.01), tear meniscus height (p = 0.03), and anaesthetised Schirmer value (p = 0.04) than fellow eyes. There were no significant differences in dry eye symptomology, meibomian gland assessments, and ocular surface staining between treated and fellow eyes (all p > 0.05). Adverse changes in tear film stability, tear osmolarity, conjunctival hyperaemia, and eyelid margins were observed in treated eyes. This suggests that inflammatory mechanisms may be implicated in the development of dry eye in patients receiving long term topical anti-glaucoma therapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Immunosuppressive therapy for eye diseases: Effectiveness, safety, side effects and their prevention

    PubMed Central

    Hornbeak, Dana M.; Thorne, Jennifer E.

    2015-01-01

    Ocular inflammation is a significant cause of ocular morbidity and visual impairment. Topical, periocular, intraocular, and systemic corticosteroids are highly effective for treating appropriate forms of ocular inflammation. However, their use may be constrained by local and/or systemic side effects, especially if long-term therapy is required. As a result, immunosuppressive agents increasingly have been used to manage ocular inflammation alongside or in place of corticosteroids. The four categories of agents used today are antimetabolites [primarily methotrexate, mycophenolate mofetil (MMF), and azathioprine]; T-cell inhibitors (usually cyclosporine, less often tacrolimus or sirolimus); alkylating agents (cyclophos-phamide and chlorambucil); and biologic agents [tumor necrosis factor (TNF) inhibitors, lymphocyte inhibitors, and interleukin inhibitors]. The primary goals of immunosuppressive therapy are (1) to control inflammation when corticosteroids fail to do so; (2) to prevent corticosteroid-induced toxicity when the necessary corticosteroid dosage exceeds the desired or safe level (corticosteroid sparing); and (3) to treat specific high-risk uveitis syndromes known to respond poorly to corticosteroids alone. Growing evidence shows the effectiveness of immunosuppressive drugs in achieving these goals, as well as improved visual function, prevention of ocular complications, and in some cases even disease remission. However, these agents also have side effects, which must be considered in each patient's management. In this report, we summarize the effectiveness and safety of immunosuppressive drug therapy utilized in the treatment of ocular inflammatory diseases. PMID:29018691

  18. Ocular toxoplasmosis II: clinical features, pathology and management.

    PubMed

    Butler, Nicholas J; Furtado, João M; Winthrop, Kevin L; Smith, Justine R

    2013-01-01

    The term, ocular toxoplasmosis, refers to eye disease related to infection with the parasite, Toxoplasma gondii. Recurrent posterior uveitis is the typical form of this disease, characterized by unilateral, necrotizing retinitis with secondary choroiditis, occurring adjacent to a pigmented retinochoroidal scar and associated with retinal vasculitis and vitritis. Multiple atypical presentations are also described, and severe inflammation is observed in immunocompromised patients. Histopathological correlations demonstrate focal coagulative retinal necrosis, and early in the course of the disease, this inflammation is based in the inner retina. For typical ocular toxoplasmosis, a diagnosis is easily made on clinical examination. In atypical cases, ocular fluid testing to detect parasite DNA by polymerase chain reaction or to determine intraocular production of specific antibody may be extremely helpful for establishing aetiology. Given the high seroprevalence of toxoplasmosis in most communities, serological testing for T. gondii antibodies is generally not useful. Despite a lack of published evidence for effectiveness of current therapies, most ophthalmologists elect to treat patients with ocular toxoplasmosis that reduces or threatens to impact vision. Classic therapy consists of oral pyrimethamine and sulfadiazine, plus systemic corticosteroid. Substantial toxicity of this drug combination has spurred interest in alternative antimicrobials, as well as local forms of drug delivery. At this time, however, no therapeutic approach is curative of ocular toxoplasmosis. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  19. Application of Hydrogel Template Strategy in Ocular Drug Delivery.

    PubMed

    Shin, Crystal S; Marcano, Daniela C; Park, Kinam; Acharya, Ghanashyam

    2017-01-01

    The hydrogel template strategy was previously developed to fabricate homogeneous polymeric microparticles. Here, we demonstrate the versatility of the hydrogel template strategy for the development of nanowafer-based ocular drug delivery systems. We describe the fabrication of dexamethasone-loaded nanowafers using polyvinyl alcohol and the instillation of a nanowafer on a mouse eye. The nanowafer, a small circular disk, is placed on the ocular surface, and it releases a drug as it slowly dissolves over time, thus increasing ocular bioavailability and enhancing efficiency to treat eye injuries.

  20. Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis--A Comprehensive Review and Guide to Therapy. I. Systemic Disease.

    PubMed

    Kohanim, Sahar; Palioura, Sotiria; Saeed, Hajirah N; Akpek, Esen K; Amescua, Guillermo; Basu, Sayan; Blomquist, Preston H; Bouchard, Charles S; Dart, John K; Gai, Xiaowu; Gomes, José A P; Gregory, Darren G; Iyer, Geetha; Jacobs, Deborah S; Johnson, Anthony J; Kinoshita, Shigeru; Mantagos, Iason S; Mehta, Jodhbir S; Perez, Victor L; Pflugfelder, Stephen C; Sangwan, Virender S; Sippel, Kimberly C; Sotozono, Chie; Srinivasan, Bhaskar; Tan, Donald T H; Tandon, Radhika; Tseng, Scheffer C G; Ueta, Mayumi; Chodosh, James

    2016-01-01

    The intent of this review is to comprehensively appraise the state of the art with regard to Stevens Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN), with particular attention to the ocular surface complications and their management. SJS and TEN represent two ends of a spectrum of immune-mediated, dermatobullous disease, characterized in the acute phase by a febrile illness followed by skin and mucous membrane necrosis and detachment. The widespread keratinocyte death seen in SJS/TEN is rapid and irreversible, and even with early and aggressive intervention, morbidity is severe and mortality not uncommon. We have divided this review into two parts. Part I summarizes the epidemiology and immunopathogenesis of SJS/TEN and discusses systemic therapy and its possible benefits. We hope this review will help the ophthalmologist better understand the mechanisms of disease in SJS/TEN and enhance their care of patients with this complex and often debilitating disease. Part II (April 2016 issue) will focus on ophthalmic manifestations. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. ACUTE METHANOL TOXICITY IN MINIPIGS

    EPA Science Inventory

    The pig hos been proposed as a potential animal model for methanol-induced neuro-ocular toxicosis in humans because of its reported low liver tetrahydro folate levels and therefore, slower formate metabolism as compared to humans. o determine the validity of the animal model, min...

  2. Severe Phenotype of Keratitis-Ichthyosis-Deafness Syndrome With Presumed Ocular Surface Squamous Neoplasia.

    PubMed

    Serrano-Ahumada, Ana Silvia; Cortes-González, Vianney; González-Huerta, Luz María; Cuevas, Sergio; Aguilar-Lozano, Luis; Villanueva-Mendoza, Cristina

    2018-02-01

    The aim of this study was to describe a case of severe keratitis-ichthyosis-deafness (KID) syndrome with ocular surface squamous neoplasia. The affected patient underwent complete ocular and systemic examinations. The molecular studies included polymerase chain reaction amplification and automated DNA sequencing of the complete gap junction beta-2 (GJB2) gene coding sequence. A 30-year-old man presented with generalized erythro-hyperkeratosis and deafness and complaints of decreased visual acuity, tearing, and photophobia. Ophthalmic examination showed corneal erosion, vascularization, and a gray gelatinous lesion partially covering the right cornea, suggestive of squamous neoplasia. The clinical features were characteristic of KID syndrome. This diagnosis was confirmed with a DNA analysis showing the pathogenic variant p.D50N in the GJB2 gene. Presumed squamous neoplasia was treated with topical interferon α2b. KID syndrome is a very rare disease that has been reported with an incremental incidence of squamous cell carcinoma of the mucous membranes and skin (12%-15%). Here, we presented a case of severe systemic KID syndrome with ocular surface squamous neoplasia.

  3. Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.

    PubMed

    Gulati, Shilpa; Jain, Sandeep

    2017-01-01

    Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.

  4. Early Changes in Ocular Surface and Tear Inflammatory Mediators after Small-Incision Lenticule Extraction and Femtosecond Laser-Assisted Laser In Situ Keratomileusis

    PubMed Central

    Gao, Shaohui; Li, Saiqun; Liu, Liangping; Wang, Yong; Ding, Hui; Li, Lili; Zhong, Xingwu

    2014-01-01

    Purpose To characterize the early ocular-surface changes or tear inflammatory-mediators levels following small-incision lenticule extraction (ReLEx smile) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). Methods Forty-seven myopic subjects were recruited for this prospective study. Fifteen underwent ReLEx smile and thirty-two underwent FS-LASIK. Corneal fluorescein (FL) staining, tear break-up time (TBUT), Schirmer I test (SIT), ocular surface disease index (OSDI) and central corneal sensitivity were evaluated in all participants. Tears were collected and analyzed for interleukin-6 (IL-6), tumor necrosis factor-α (TNF-α), nerve growth factor (NGF) and intercellular adhesion molecule-1 (ICAM-1) levels using multiplex magnetic beads. All measurements were preformed preoperatively and 1 day, 1 week, 1 month and 3 months postoperatively. Results FL scores in ReLEx smile group were lower than those of FS-LASIK group 1 week postoperatively (P = 0.010). Compared to the FS-LASIK group, longer TBUT were observed in ReLEx smile group 1 month (P = 0.029) and 3 months (P = 0.045) postoperatively. No significant differences were found in tear secretion for the two groups (P>0.05). OSDI scores were higher in FS-LASIK group 1 month after surgery (P = 0.020). Higher central corneal sensitivity was observed in ReLEx smile group 1 week, 1 month and 3 months (P<0.05) postoperatively. Compared to FS-LASIK group, lower and faster recovery of IL-6 and NGF levels in tears was observed in ReLEx smile group postoperatively (P<0.05). Tears TNF-α and ICAM-1 concentrations were not significantly different between the two groups at any follow-up time (P>0.05). Moreover, IL-6 and NGF levels correlated with ocular surface changes after ReLEx smile or FS-LASIK. Conclusions In the early postoperative period, ReLEx smile results in milder ocular surface changes than FS-LASIK. Furthermore, the tear inflammatory mediators IL-6 and NGF may play a crucial role in the ocular surface healing process following ReLEx smile and FS-LASIK. PMID:25211490

  5. Early changes in ocular surface and tear inflammatory mediators after small-incision lenticule extraction and femtosecond laser-assisted laser in situ keratomileusis.

    PubMed

    Gao, Shaohui; Li, Saiqun; Liu, Liangping; Wang, Yong; Ding, Hui; Li, Lili; Zhong, Xingwu

    2014-01-01

    To characterize the early ocular-surface changes or tear inflammatory-mediators levels following small-incision lenticule extraction (ReLEx smile) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). Forty-seven myopic subjects were recruited for this prospective study. Fifteen underwent ReLEx smile and thirty-two underwent FS-LASIK. Corneal fluorescein (FL) staining, tear break-up time (TBUT), Schirmer I test (SIT), ocular surface disease index (OSDI) and central corneal sensitivity were evaluated in all participants. Tears were collected and analyzed for interleukin-6 (IL-6), tumor necrosis factor-α (TNF-α), nerve growth factor (NGF) and intercellular adhesion molecule-1 (ICAM-1) levels using multiplex magnetic beads. All measurements were preformed preoperatively and 1 day, 1 week, 1 month and 3 months postoperatively. FL scores in ReLEx smile group were lower than those of FS-LASIK group 1 week postoperatively (P = 0.010). Compared to the FS-LASIK group, longer TBUT were observed in ReLEx smile group 1 month (P = 0.029) and 3 months (P = 0.045) postoperatively. No significant differences were found in tear secretion for the two groups (P>0.05). OSDI scores were higher in FS-LASIK group 1 month after surgery (P = 0.020). Higher central corneal sensitivity was observed in ReLEx smile group 1 week, 1 month and 3 months (P<0.05) postoperatively. Compared to FS-LASIK group, lower and faster recovery of IL-6 and NGF levels in tears was observed in ReLEx smile group postoperatively (P<0.05). Tears TNF-α and ICAM-1 concentrations were not significantly different between the two groups at any follow-up time (P>0.05). Moreover, IL-6 and NGF levels correlated with ocular surface changes after ReLEx smile or FS-LASIK. In the early postoperative period, ReLEx smile results in milder ocular surface changes than FS-LASIK. Furthermore, the tear inflammatory mediators IL-6 and NGF may play a crucial role in the ocular surface healing process following ReLEx smile and FS-LASIK.

  6. Glaucoma management: relative value and place in therapy of available drug treatments

    PubMed Central

    Sambhara, Deepak

    2014-01-01

    Lowering intraocular pressure (IOP) is the only proven therapeutic intervention for glaucomatous optic neuropathy. Despite advances in laser and microsurgical techniques, medical IOP reduction remains the first-line treatment option for the majority of patients with open-angle glaucoma. Prostaglandin analogs are the most efficacious topical agents and carry a remarkable safety profile. Topical beta-blockers, alpha-agonists, and carbonic anhydrase inhibitors are often employed as adjunctive agents for further IOP control. Newer preserved and nonpreserved formulations are available and appear to be less toxic to the ocular surface. Oral carbonic anhydrase inhibitors, miotic agents, and hyperosmotics are infrequently used due to a host of potentially serious adverse events. Medical therapies on the horizon include rho-kinase inhibitors, neuroprotective interventions, and gene therapies. PMID:24381726

  7. The clinical and cellular basis of contact lens-related corneal infections

    PubMed Central

    Robertson, Danielle M; Cavanagh, H Dwight

    2008-01-01

    Microbial keratitis (MK) is the most visually devastating complication associated with contact lens wear. Pseudomonas aeruginosa (PA) is highly invasive in the corneal epithelium and is responsible for more than half of the reported cases of contact lens-related MK. To protect against Pseudomonas-mediated MK, the corneal epithelium has evolved overlapping defense mechanisms that function to protect the ocular surface from microbial invasion. Research has shown that contact lens wear disrupts these protective mechanisms through breakdown of normal homeostatic surface renewal as well as damaging the corneal surface, exposing underlying cell membrane receptors that bind and internalize PA through the formation of lipid rafts. Human clinical trials have shown that initial adherence of PA with resulting increased risk for microbial infection is mediated in part by contact lens oxygen transmissibility. Recently, chemical preserved multipurpose solutions (MPS) have been implicated in increasing PA adherence to corneal epithelial cells, in addition to inducing significant levels of toxic staining when used in conjunction with specific silicone hydrogel lenses. This review summarizes what is currently known about the relationship between contact lenses, the corneal epithelium, MPS, and infection. PMID:19277209

  8. Computer vision syndrome: a review.

    PubMed

    Blehm, Clayton; Vishnu, Seema; Khattak, Ashbala; Mitra, Shrabanee; Yee, Richard W

    2005-01-01

    As computers become part of our everyday life, more and more people are experiencing a variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation, redness, blurred vision, and double vision, collectively referred to as computer vision syndrome. This article describes both the characteristics and treatment modalities that are available at this time. Computer vision syndrome symptoms may be the cause of ocular (ocular-surface abnormalities or accommodative spasms) and/or extraocular (ergonomic) etiologies. However, the major contributor to computer vision syndrome symptoms by far appears to be dry eye. The visual effects of various display characteristics such as lighting, glare, display quality, refresh rates, and radiation are also discussed. Treatment requires a multidirectional approach combining ocular therapy with adjustment of the workstation. Proper lighting, anti-glare filters, ergonomic positioning of computer monitor and regular work breaks may help improve visual comfort. Lubricating eye drops and special computer glasses help relieve ocular surface-related symptoms. More work needs to be done to specifically define the processes that cause computer vision syndrome and to develop and improve effective treatments that successfully address these causes.

  9. Ocular surface disease incidence in patients with open-angle glaucoma.

    PubMed

    Radenković, Marija; Stanković-Babić, Gordana; Jovanović, Predrag; Djordjević-Jocić, Jasmina; Trenkić-Božinović, Marija

    2016-01-01

    Ocular surface disease (OSD) is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren) and evaporative (extrinsic and intrinsic) form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride – BAK), which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Retrospective analysis of examined patients with open-angle glaucoma was used. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma). Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.

  10. Impact of oral vitamin D supplementation on the ocular surface in people with dry eye and/or low serum vitamin D.

    PubMed

    Yang, Chih-Huang; Albietz, Julie; Harkin, Damien G; Kimlin, Michael G; Schmid, Katrina L

    2018-02-01

    To determine the possible association between serum vitamin D levels and dry eye symptoms, and the impact of an oral vitamin D supplement. Three linked studies were performed. (i) 29 older adult participants, (ii) 29 dry eyed participants, and (iii) 2-month vitamin D supplementation for 32 dry eyed/low serum vitamin D levelled participants. All participants were assessed by the Ocular Surface Diseases Index (OSDI) to determine dry eye symptoms, and the phenol red thread test (PRT) and/or Schirmer's tear test, tear meniscus height, non-invasive tear break up time, grading ocular surface redness and fluorescein staining of the cornea to detect the tear quality and ocular surface conditions. Blood samples were collected for serum vitamin D analysis and interleukin-6 (IL-6) levels. Among older adult participants, vitamin D levels were negatively correlated with dry eye symptoms, the severity of dry eye, and associated with tired eye symptom. Vitamin D levels of people with dry eye diagnosis were not correlated with OSDI scores and IL-6 levels; while IL-6 levels showed correlation with tear production. In supplement study, vitamin D levels increased by 29mol/l, while dry eye symptoms and grading of corneal staining appeared significant reductions. No significant changes in IL-6 levels. Low vitamin D levels (<50nmol/l) were associated with dry eye symptoms in older individuals but not those diagnosed with dry eye. Vitamin D supplement increased the vitamin D levels, and improved dry eye symptoms, the tear quality and ocular surface conditions. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  11. [Oral flaxseed oil (Linum usitatissimum) in the treatment for dry-eye Sjögren's syndrome patients].

    PubMed

    Pinheiro, Manuel Neuzimar; dos Santos, Procópio Miguel; dos Santos, Regina Cândido Ribeiro; Barros, Jeison de Nadai; Passos, Luiz Fernando; Cardoso Neto, José

    2007-01-01

    To evaluate if oral flaxseed oil (Linum usitatissimum), which reduces the inflammation in rheumatoid arthritis, may help keratoconjunctivitis sicca's treatment in Sjögren's syndrome patients. In a randomized clinical trial, 38 female patients with rheumatoid arthritis or systemic lupus erithematosus associated with keratoconjunctivitis sicca and Sjögren's syndrome were consecutively selected from patients of the Department of Rheumatology of the Amazonas University Hospital. Keratoconjunctivitis sicca diagnosis was based on a dry-eye symptom survey score (Ocular Surface Disease Index - OSDI), Schirmer-I test, fluorescein break-up time, 1% Rose Bengal staining of ocular surface measured by the van Bijsterveld scale. All patients had ocular surface inflammation evaluated and quantified by conjunctival impression cytology, before and after the study. The subjects were divided into three groups with 13 (Group I), 12 (Group II) and 13 (Group III) patients. Group I received flaxseed oil capsules with a final 1 g/day dosis, Group II flaxseed oil capsules with a final 2 g/day dosis and Group III - controls - placebo, for 180 days. Comparing the results at the beginning and at the end of the treatment, statistically significant changes (p<0.05) in symptoms (OSDI), ocular surface inflammation quantified by conjunctival impression cytology, Schirmer-I test and fluorescein break-up time occurred in Groups I e II when compared to controls. Therapy with oral flaxseed oil capsules 1 or 2 g/day reduces ocular surface inflammation and ameliorates the symptoms of keratoconjunctivitis sicca in Sjögren's syndrome patients. Long-term studies are needed to confirm the role of this therapy for keratoconjunctivitis sicca in Sjögren's syndrome.

  12. Corneal and conjunctival sensory function: the impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses.

    PubMed

    Golebiowski, Blanka; Papas, Eric B; Stapleton, Fiona

    2012-03-09

    Deprivation of oxygen to the ocular surface during contact lens wear has been implicated in the alteration of sensory function. This study investigates whether increasing oxygen availability through discontinuation of contact lens wear or transfer into highly oxygen transmissible (high Dk/t) lenses leads to a change in corneal or conjunctival sensitivity. Twenty-seven long-term extended wearers of low Dk/t soft contact lenses ceased lens wear for 1 week and were refitted with high Dk/t silicone hydrogel lenses. A control group of 25 nonwearers matched for age and sex was also recruited. Central corneal and inferior conjunctival sensitivity were measured using an air-jet aesthesiometer. Threshold was determined using a staircase technique. Measurements were taken during low Dk/t lens wear; after 1 week of no wear; and after 1, 3, 6, and 12 months of high Dk/t lens wear. Measurements were carried out on one occasion on the nonwearers. Corneal sensitivity decreased 1 week after discontinuation of low Dk/t lenses and no further change in sensitivity occurred with high Dk/t lens wear. Conjunctival sensitivity did not change over the same time frame. Ocular surface sensitivity in long-term low Dk/t soft lens wearers was similar to that of nonwearers. Sensitivity was higher in females than males in the nonwearers, but not in the lens-wearing group. An interaction of sex on change in conjunctival threshold was found in the lens wearers. These findings indicate that factors other than oxygen availability alone determine sensitivity of the ocular surface. Silicone hydrogel contact lenses appear to have only a minor impact on ocular surface sensitivity in previous lens wearers.

  13. Temperatures of the Ocular Surface, Lid, and Periorbital Regions of Sjögren's, Evaporative, and Aqueous-Deficient Dry Eyes Relative to Normals.

    PubMed

    Abreau, Kerstin; Callan, Christine; Kottaiyan, Ranjini; Zhang, Aizhong; Yoon, Geunyoung; Aquavella, James V; Zavislan, James; Hindman, Holly B

    2016-01-01

    To compare the temperatures of the ocular surface, eyelid, and periorbital skin in normal eyes with Sjögren's syndrome (SS) eyes, evaporative dry eyes (EDE), and aqueous deficient dry eyes (ADDE). 10 eyes were analyzed in each age-matched group (normal, SS, EDE, and ADDE). A noninvasive infrared thermal camera captured two-dimensional images in three regions of interest (ROI) in each of three areas: the ocular surface, the upper eyelid, and the periorbital skin within a controlled environmental chamber. Mean temperatures in each ROI were calculated from the videos. Ocular surface time-segmented cooling rates were calculated over a 5-s blink interval. Relative to normal eyes, dry eyes had lower initial central OSTs (SS -0.71°C, EDE -0.55°C, ADDE -0.95°C, KW P<.0001) and lower central upper lid temperatures (SS -0.24°C, ADDE -0.51°C, and EDE -0.54°C, KW P<.0001). ADDE eyes had the lowest initial central OST (P<.0001), while EDE eyes had the lowest central lid temperature and lower periorbital temperatures (P<.0001). Over the 5-s interblink interval, the greatest rate of temperature loss occurred following eyelid opening, but varied by group (normals -0.52, SS -0.73, EDE -0.63, and ADDE -0.75°C/s). The ADDE group also had the most substantial heat loss over the 5-s interblink interval (-0.97°C). Differences in OST may be related to thermal differences in lids and periorbita along with an altered tear film. Thermography of the ocular surface, lids, and surrounding tissues may help to differentiate between different etiologies of dry eye. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Phototoxic effects of an operating microscope on the ocular surface and tear film.

    PubMed

    Hwang, Hyung Bin; Kim, Hyun Seung

    2014-01-01

    We evaluated light exposure-induced dry eye syndrome by investigating the phototoxic effects of an operating microscope on the ocular surface and tear film in rabbits. Sixty eyes of 30 rabbits were divided into 3 groups based on the intensity of light exposure received from an operating microscope: Control group, no exposure to light; group A, 40,000-lx intensity for 30 minutes; and group B, 100,000-lx intensity for 30 minutes. To evaluate the potential damage to the ocular surface and tear film, Schirmer tests, rose bengal staining, and conjunctival impression cytology were performed before the light exposure and at 1, 3, and 5 days afterward. In addition, the expression of interleukin 1-beta was analyzed in tear samples. The expression of mucin 5AC was evaluated using immunofluorescence staining, and periodic acid-Schiff staining was conducted on conjunctival tissues. Corneal and conjunctival tissues were observed by means of electron microscopy. Potential damage to the ocular surface and tear film was found in the light-exposed groups as evidenced by decreased aqueous tear production, devitalized corneal and conjunctival epithelial cells, squamous metaplasia of conjunctival epithelial cells, decreased conjunctival goblet cell density, decreased expression of mucin 5AC, ultrastructural cellular damage to corneal and conjunctival tissues, and increased interleukin 1-beta expression in tears. This damage was more noticeable in group B than in group A (P < 0.05). Light exposure from an operating microscope had phototoxic effects on the ocular surface and tear film in this in vivo experiment. These changes seemed to intensify as the intensity of the light increased. Therefore, excessive light exposure during ophthalmic procedures could be a pathogenic factor in dry eye syndrome after a surgery is performed.

  15. Therapeutic Effect of Human Adipose Tissue-Derived Mesenchymal Stem Cells in Experimental Corneal Failure Due to Limbal Stem Cell Niche Damage.

    PubMed

    Galindo, Sara; Herreras, José M; López-Paniagua, Marina; Rey, Esther; de la Mata, Ana; Plata-Cordero, María; Calonge, Margarita; Nieto-Miguel, Teresa

    2017-10-01

    Limbal stem cells are responsible for the continuous renewal of the corneal epithelium. The destruction or dysfunction of these stem cells or their niche induces limbal stem cell deficiency (LSCD) leading to visual loss, chronic pain, and inflammation of the ocular surface. To restore the ocular surface in cases of bilateral LSCD, an extraocular source of stem cells is needed to avoid dependence on allogeneic limbal stem cells that are difficult to obtain, isolate, and culture. The aim of this work was to test the tolerance and the efficacy of human adipose tissue-derived mesenchymal stem cells (hAT-MSCs) to regenerate the ocular surface in two experimental models of LSCD that closely resemble different severity grades of the human pathology. hAT-MSCs transplanted to the ocular surface of the partial and total LSCD models developed in rabbits were well tolerated, migrated to inflamed tissues, reduced inflammation, and restrained the evolution of corneal neovascularization and corneal opacity. The expression profile of the corneal epithelial cell markers CK3 and E-cadherin, and the limbal epithelial cell markers CK15 and p63 was lost in the LSCD models, but was partially recovered after hAT-MSC transplantation. For the first time, we demonstrated that hAT-MSCs improve corneal and limbal epithelial phenotypes in animal LSCD models. These results support the potential use of hAT-MSCs as a novel treatment of ocular surface failure due to LSCD. hAT-MSCs represent an available, non-immunogenic source of stem cells that may provide therapeutic benefits in addition to reduce health care expenses. Stem Cells 2017;35:2160-2174. © 2017 AlphaMed Press.

  16. Differential regulation of membrane-associated mucins in the human ocular surface epithelium.

    PubMed

    Hori, Yuichi; Spurr-Michaud, Sandra; Russo, Cindy Leigh; Argüeso, Pablo; Gipson, Ilene K

    2004-01-01

    Membrane-associated mucins present in the apical cells of the ocular surface epithelium (MUC1, -4, and -16) are believed to contribute to the maintenance of a hydrated and wet-surfaced epithelial phenotype. Serum and retinoic acid (RA) have been used to treat drying ocular surface diseases. The goal of this study was to determine whether serum or RA regulates the production of membrane-associated mucins in human conjunctival epithelial cells. A telomerase-immortalized human conjunctival epithelial cell line (HCjE) was used. Cells were cultured in serum-free medium to confluence and then cultured with either 10% calf serum or with 100 nM RA for 0 to 72 hours. Conventional RT-PCR was used to determine the expression of retinoic acid receptors (RARs) and quantitative real-time PCR was used to investigate the mRNA expression of MUC1, -4, and -16. Protein levels were assayed by immunoblot analysis, using the antibodies HMFG-2, 1G8, or OC125, which are specific to MUC1, -4 and -16, respectively. To determine whether RA-associated MUC4 mRNA induction is a direct or indirect effect, HCjE cells were treated with RA and the protein synthesis inhibitor cycloheximide (1.0 microg/mL) for 12 hours. MUC1 and -16, but not -4, mRNAs were detectable in HCjE cells grown in serum-free medium. Real-time PCR revealed that MUC4 mRNA was significantly induced by serum 3 hours after its addition, and that MUC1 and MUC16 mRNA levels were significantly upregulated at 72 hours. Western blot analysis demonstrated that the MUC1, -4, and -16 proteins increased over time after addition of serum. Conventional RT-PCR analysis demonstrated that RAR-alpha and -gamma mRNA were expressed in native human conjunctival tissue as well as in the HCjE cells. Treatment with RA upregulated the expression of both MUC4 and -16 mRNA and protein, but MUC1 was unaffected. Because the protein synthesis inhibitor cycloheximide did not prevent the RA-associated induction of MUC4 mRNA, the action of RA on the MUC4 promoter may be direct. The membrane-associated mucins of the ocular surface epithelia, MUC1, -4, and -16, are differentially regulated by serum and RA in the telomerase-immortalized human conjunctival epithelial cell line. Serum derived from vessels in the conjunctiva may play an important role in mucin regulation in the ocular surface epithelia. These data also support the clinical efficacy of autologous serum and RA application in patients with ocular surface diseases. Furthermore, the data suggest that MUC4 and -16 are particularly important hydrophilic molecules involved in maintenance of a healthy ocular surface.

  17. Recent developments on dry eye disease treatment compounds

    PubMed Central

    Colligris, Basilio; Alkozi, Hanan Awad; Pintor, Jesus

    2013-01-01

    Dry eye syndrome is a common tears and ocular surface multifactorial disease, described by changes in the ocular surface epithelia related to reduced tears quantity and ocular surface sensitivity, leading to inflammatory reaction. Managing the eye inflammation proved helpful to patients with dry eye disease and current treatment is based on the use of topically applied artificial tear products/lubricants, tear retention management, stimulation of tear secretion and using anti-inflammatory drugs. In this article we revise the corresponding literature and patents assembling the new treatment approaches of novel and future pharmaceutical compounds destined for the dry eye disease treatment. The most frequent categories of compounds presented are secretagogues and anti-inflammatory drugs. These compounds are the research outcome of novel therapeutic strategies designed to reduce key inflammatory pathways and restore healthy tear film. PMID:24526854

  18. Dry eyes: etiology and management.

    PubMed

    Latkany, Robert

    2008-07-01

    Until recently, the cause of dry eye syndrome was uncertain and the treatment was palliative. Since discovering that dry eyes are caused by inflammation, there has been an abundance of research focusing on anti-inflammatory therapies, other contributing causes, and better diagnostic testing. This review summarizes some of the interesting published research on ocular surface disease over the past year. The definition of dry eye now highlights the omnipresent symptom of blurry vision. The re-evaluation of ocular surface staining, tear meniscus height, and visual change will allow for a better diagnosis and understanding of dry eyes. Punctal plugs, and oral and topical anti-inflammatory use will strengthen our arsenal against ocular surface disease. Major progress has occurred in the past few years in gaining a better understanding of the etiology of dry eye syndrome, which will inevitably lead to more effective therapeutic options.

  19. Expression Analysis of the Transmembrane Mucin MUC20 in Human Corneal and Conjunctival Epithelia

    PubMed Central

    Woodward, Ashley M.; Argüeso, Pablo

    2014-01-01

    Purpose. Cell surface mucins are a group of highly O-glycosylated transmembrane glycoproteins responsible for the protection of epithelial cells on mucosal surfaces. The aim of this study was to investigate the localization and regulation of mucin 20 (MUC20) at the ocular surface. Methods. Localization of MUC20 in human corneal and conjunctival epithelia was evaluated by immunofluorescence microscopy. Immortalized corneal (HCLE) and conjunctival (HCjE) cell lines were grown at different stages of differentiation and subjected to quantitative PCR and Western blot analyses. Cell surface proteins on apical cell membranes were biotinylated and isolated by neutravidin chromatography. Results. The MUC20 was detected throughout the entire human ocular surface epithelia, predominantly in cell membranes within intermediate cell layers. In conjunctiva, MUC20 also was observed in the cytoplasm of apical cells within the stratified squamous epithelium, but not in goblet cells. Quantitative PCR and immunoblotting demonstrated expression of MUC20 in HCLE and HCjE cells. Induction of differentiation with serum-containing medium resulted in upregulation of MUC20 mRNA and protein. Biotin labeling of the surface of stratified cultures revealed low levels of MUC20 protein on apical glycocalyces. Further, MUC20 was not detected in the cell culture media or in human tears, suggesting that the extracellular domain of MUC20 is not released from the ocular surface as described previously for other cell surface mucins. Conclusions. Our results indicate that MUC20 is a novel transmembrane mucin expressed by the human corneal and conjunctival epithelia, and suggest that differential expression of MUC20 during differentiation has a role in maintaining ocular surface homeostasis. PMID:25168902

  20. Dry eye disease caused by viral infection: review.

    PubMed

    Alves, Monica; Angerami, Rodrigo Nogueira; Rocha, Eduardo Melani

    2013-01-01

    Dry eye disease and ocular surface disorders may be caused or worsened by viral agents. There are several known and suspected virus associated to ocular surface diseases. The possible pathogenic mechanisms for virus-related dry eye disease are presented herein. This review serves to reinforce the importance of ophthalmologists as one of the healthcare professional able to diagnose a potentially large number of infected patients with high prevalent viral agents.

  1. Relevance of Lipid-Based Products in the Management of Dry Eye Disease

    PubMed Central

    Amrane, Mourad; Faure, Marie-Odile; Holopainen, Juha M.; Tong, Louis

    2017-01-01

    Abstract Components of the ocular surface synergistically contribute to maintaining and protecting a smooth refractive layer to facilitate the optimal transmission of light. At the air–water interface, the tear film lipid layer (TFLL), a mixture of lipids and proteins, plays a key role in tear surface tension and is important for the physiological hydration of the ocular surface and for ocular homeostasis. Alterations in tear fluid rheology, differences in lipid composition, or downregulation of specific tear proteins are found in most types of ocular surface disease, including dry eye disease (DED). Artificial tears have long been a first line of treatment in DED and aim to replace or supplement tears. More recently, lipid-containing eye drops have been developed to more closely mimic the combination of aqueous and lipid layers of the TFLL. Over the last 2 decades, our understanding of the nature and importance of lipids in the tear film in health and disease has increased substantially. The aim of this article is to provide a brief overview of our current understanding of tear film properties and review the effectiveness of lipid-based products in the treatment of DED. Liposome lid sprays, emulsion eye drops, and other lipid-containing formulations are discussed. PMID:28956698

  2. Comparison of Cornea Module and DermaInspect for noninvasive imaging of ocular surface pathologies

    NASA Astrophysics Data System (ADS)

    Steven, Philipp; Müller, Maya; Koop, Norbert; Rose, Christian; Hüttmann, Gereon

    2009-11-01

    Minimally invasive imaging of ocular surface pathologies aims at securing clinical diagnosis without actual tissue probing. For this matter, confocal microscopy (Cornea Module) is in daily use in ophthalmic practice. Multiphoton microscopy is a new optical technique that enables high-resolution imaging and functional analysis of living tissues based on tissue autofluorescence. This study was set up to compare the potential of a multiphoton microscope (DermaInspect) to the Cornea Module. Ocular surface pathologies such as pterygia, papillomae, and nevi were investigated in vivo using the Cornea Module and imaged immediately after excision by DermaInspect. Two excitation wavelengths, fluorescence lifetime imaging and second-harmonic generation (SHG), were used to discriminate different tissue structures. Images were compared with the histopathological assessment of the samples. At wavelengths of 730 nm, multiphoton microscopy exclusively revealed cellular structures. Collagen fibrils were specifically demonstrated by second-harmonic generation. Measurements of fluorescent lifetimes enabled the highly specific detection of goblet cells, erythrocytes, and nevus-cell clusters. At the settings used, DermaInspect reaches higher resolutions than the Cornea Module and obtains additional structural information. The parallel detection of multiphoton excited autofluorescence and confocal imaging could expand the possibilities of minimally invasive investigation of the ocular surface toward functional analysis at higher resolutions.

  3. Investigational and experimental drugs for intraocular pressure reduction in ocular hypertension and glaucoma.

    PubMed

    Lusthaus, Jed Asher; Goldberg, Ivan

    2016-10-01

    Intraocular pressure (IOP) is the most significant modifiable risk factor to prevent onset or progression of glaucoma. Glaucoma prevalence continues to increase, emphasizing the need for improved ocular hypotensive treatment options. To try to improve on both tolerance and IOP control of currently available therapies, different receptors or mechanisms are being explored to reduce IOP more effectively and to improve tolerance. We review synthetic topical and oral drugs in early development for the management of ocular hypertension and glaucoma. New therapeutic agents for IOP control have been discovered; some appear to be reasonably tolerated. IOP reduction may be limited with some agents, but other benefits although unproven may compensate for this, such as less ocular surface disease, enhanced neuro-protection or increased ocular blood flow. Further product development promises improved treatment options for ocular hypertensives and glaucoma sufferers.

  4. Ocular surface disease in patients with glaucoma or ocular hypertension treated with either BAK-preserved latanoprost or BAK-free travoprost

    PubMed Central

    Katz, Gregory; Springs, Clark L; Craven, E Randy; Montecchi-Palmer, Michela

    2010-01-01

    Purpose The preservative benzalkonium chloride (BAK) may adversely affect ocular surface health. This study evaluated symptoms of ocular surface disease (OSD) in patients previously treated with a BAK-preserved therapy to lower their intraocular pressure, who either continued that therapy or switched to a BAK-free therapy. Methods Eligible adult patients with ocular hypertension or open-angle glaucoma that had been controlled with BAK-preserved latanoprost 0.005% monotherapy (Xalatan®) for at least one month and had a score of ≥ 13 (0 = none, 100 = most severe) on the Ocular Surface Disease Index (OSDI) questionnaire were entered into this prospective, double-masked, randomized, active-controlled, multicenter trial. By random assignment, patients either continued with BAK-preserved latanoprost 0.005% or transitioned to BAK-free travoprost 0.004% (Travatan Z® ophthalmic solution). OSDI scores were assessed again after six and 12 weeks. Results For the 678 evaluable patients, mean change in OSDI score from baseline to week 12 favored the travoprost 0.004% BAK-free group, but was not statistically different between groups (P = 0.10). When patients with mild OSD at baseline were assessed after 12 weeks, the mean OSDI score was significantly lower (P = 0.04) in the BAK-free travoprost 0.004% group (score = 11.6 ± 10.8 units) than in the BAK-preserved latanoprost 0.005% group (score = 14.4 ± 11.9 units), and a significantly larger percentage (P < 0.01) improved to normal OSDI scores in the BAK-free travoprost 0.004% group (62.9% of group) than in the BAK-preserved latanoprost 0.005% group (47.0% of group). Patients pretreated with BAK-preserved latanoprost 0.005% for >24 months were significantly more likely (P = 0.03) to improve to a normal OSDI score after 12 weeks if they were switched to BAK-free travoprost 0.004% (47.9% of group) than if they remained on BAK-preserved latanoprost 0.005% (33.9% of group). Conclusions Switching from BAK-preserved latanoprost 0.005% to BAK-free travoprost 0.004% yielded significant improvements in symptoms of OSD in patients with glaucoma or ocular hypertension. PMID:21151330

  5. Randomised masked trial of the clinical safety and tolerability of MGO Manuka Honey eye cream for the management of blepharitis

    PubMed Central

    Craig, Jennifer P; Wang, Michael T M; Ganesalingam, Kalaivarny; Rupenthal, Ilva D; Swift, Simon; Loh, Chee Seang; Te Weehi, Leah; Cheung, Isabella M Y; Watters, Grant A

    2017-01-01

    Objective To assess the clinical safety and tolerability of a novel MGO Manuka Honey microemulsion (MHME) eye cream for the management of blepharitis in human subjects. Methods and analysis Twenty-five healthy subjects were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. The MHME eye cream (Manuka Health New Zealand) was applied to the closed eyelids of one eye (randomised) overnight for 2 weeks. LogMAR visual acuity, eyelid irritation symptoms, ocular surface characteristics and tear film parameters were assessed at baseline, day 7 and day 14. Expression of markers of ocular surface inflammation (matrix metalloproteinase-9 and interleukin-6) and goblet cell function (MUC5AC) were quantified using impression cytology at baseline and day 14. Results There were no significant changes in visual acuity, eyelid irritation symptoms, ocular surface characteristics, tear film parameters and inflammatory marker expression during the 2-week treatment period in treated and control eyes (all p>0.05), and measurements did not differ significantly between eyes (all p>0.05). No major adverse events were reported. Two subjects experienced transient ocular stinging, presumably due to migration of the product into the eye, which resolved following aqueous irrigation. Conclusion The MHME eye cream application was found to be well tolerated in healthy human subjects and was not associated with changes in visual acuity, ocular surface characteristics, tear film parameters, expression of markers of inflammation or goblet cell function. The findings support future clinical efficacy trials in patients with blepharitis. Trial registration number ACTRN12616000540415 PMID:29354710

  6. Analysis of Factors Associated With the Tear Film Lipid Layer Thickness in Normal Eyes and Patients With Dry Eye Syndrome.

    PubMed

    Jung, Ji Won; Park, Si Yoon; Kim, Jin Sun; Kim, Eung Kweon; Seo, Kyoung Yul; Kim, Tae-Im

    2016-08-01

    To determine the effects of clinical variables, including age, sex, history of refractive or cataract surgery, contact lens use, and ocular surface and meibomian gland parameters on the lipid layer thickness (LLT) in normal subjects and patients with dry eye syndrome (DES). A total of 64 normal subjects and 326 patients with DES were enrolled, and they underwent measurements of LLT with a LipiView interferometer and tear meniscus height using optical coherence tomography, tear film break-up time (TBUT) determination, ocular surface staining, Schirmer's test, examination of the lid margins and meibomian glands, and assessment using the Ocular Surface Disease Index (OSDI). In normal subjects, the median (range) LLT was 67 (33-100) nm, and age was the only factor that was significantly associated with LLT (β = 0.678, P = 0.028). In patients with DES, the median (range) LLT was 84 (20-100) nm, and 79.0% of the participants fulfilled the diagnostic criteria for meibomian gland dysfunction (MGD). In a multivariate analysis, increased age and female sex were significantly related to increased LLT (β = 0.282, P = 0.005 and β = 11.493, P < 0.001), and hypersecretory MGD and lid margin inflammation were independently associated with increased LLT (β = 11.299, P = 0.001 and β = 12.747, P = 0.001). Lipid layer thickness measurements using a new interferometer are significantly affected by demographic factors such as age, sex, ocular surgical history, and MGD type. Therefore, all of these factors must be considered in the diagnosis of ocular surface diseases.

  7. Ocular surface temperature in patients with evaporative and aqueous-deficient dry eyes: a thermographic approach.

    PubMed

    Matteoli, S; Favuzza, E; Mazzantini, L; Aragona, P; Cappelli, S; Corvi, A; Mencucci, R

    2017-07-26

    In recent decades infrared thermography (IRT) has facilitated accurate quantitative measurements of the ocular surface temperature (OST), applying a non-invasive procedure. The objective of this work was to develop a procedure based on IRT, which allows characterizing of the cooling of the ocular surface of patients suffering from dry eye syndrome, and distinguishing among patients suffering from aqueous deficient dry eye (ADDE) and evaporative dry eyes (EDE). All patients examined (34 females and 4 males, 23-84 years) were divided into two groups according to their Schirmer I result (⩽ 7 mm for ADDE and  >  7 mm for EDE), and the OST was recorded for 7 s at 30 Hz. For each acquisition, the temperatures of the central cornea (CC) as well as those of both temporal and nasal canthi were investigated. Findings showed that the maximum temperature variation (up to 0.75  ±  0.29 °C) was at the CC for both groups. Furthermore, patients suffering from EDE tended to have a higher initial OST than those with ADDE, explained by the greater quantity of the tear film, evenly distributed over the entire ocular surface, keeping the OST higher initially. Results also showed that EDE patients had an average cooling rate higher than those suffering from ADDE, confirming the excessive evaporation of the tear film. Ocular thermography paves the way to become an effective tool for differentiating between the two different etiologies of dry eye syndrome.

  8. The cellular mechanisms of dry eye: from pathogenesis to treatment.

    PubMed

    Mantelli, Flavio; Massaro-Giordano, Mina; Macchi, Ilaria; Lambiase, Alessandro; Bonini, Stefano

    2013-12-01

    Dry eye is a complex disease characterized by changes in the ocular surface epithelia related to reduced quality and/or quantity of tears, inflammatory reaction, and impairment of ocular surface sensitivity. It has recently been proposed that increased tear osmolarity represents a main trigger to the altered cellular mechanisms leading to epithelial damage in dry eye. However, dry eye pathogenesis is multifactorial, with cytotoxic inflammatory mediators, altered lacrimal gland secretion and nerve function, squamous metaplasia of the conjunctival epithelium and decrease of goblet cells density, all playing a role in a detrimental loop that perpetuates and worsens damage to the corneal and conjunctival epithelia. Current topical treatments for dry eye patients include the use of lubricants and anti-inflammatory drugs. However, lubricants only improve symptoms temporarily, and chronic use of topical steroids is associated to severe ocular side effects such as cataract and glaucoma. The deeper understanding of the cellular mechanisms that are altered in dry eye is opening novel perspectives for patients and physicians, who are seeking treatments capable not only of improving symptoms but also of restoring the homeostasis of the ocular surface. In this review, we will focus on novel anti-inflammatory agents and on nerve growth factor, a neurotrophin that is altered in dry eye and has been suggested as a main player in the neuroimmune cross-talk of the ocular surface as well as in the stimulation of corneal sensitivity, epithelial proliferation and differentiation, and stimulation of mucin production by goblet cells. J. Cell. Physiol. 228: 2253-2256, 2013. © 2013 Wiley Periodicals, Inc. Copyright © 2013 Wiley Periodicals, Inc.

  9. Ocular complications of diabetes mellitus

    PubMed Central

    Sayin, Nihat; Kara, Necip; Pekel, Gökhan

    2015-01-01

    Diabetes mellitus (DM) is a important health problem that induces ernestful complications and it causes significant morbidity owing to specific microvascular complications such as, retinopathy, nephropathy and neuropathy, and macrovascular complications such as, ischaemic heart disease, and peripheral vasculopathy. It can affect children, young people and adults and is becoming more common. Ocular complications associated with DM are progressive and rapidly becoming the world’s most significant cause of morbidity and are preventable with early detection and timely treatment. This review provides an overview of five main ocular complications associated with DM, diabetic retinopathy and papillopathy, cataract, glaucoma, and ocular surface diseases. PMID:25685281

  10. Evaluation of Ocular Surface Disease in Patients with Glaucoma

    PubMed Central

    Mathews, Priya M.; Ramulu, Pradeep Y.; Friedman, David S.; Utine, Canan A.; Akpek, Esen K.

    2013-01-01

    Purpose To evaluate the subjective and objective measures of ocular surface disease in patients with glaucoma. Design Cross-sectional study. Participants Sixty-four glaucoma subjects with bilateral visual field (VF) loss and 59 glaucoma suspects with normal VFs. Methods Consecutive patients were recruited prospectively from the Wilmer Eye Institute Glaucoma Clinic. Main Outcome Measures Tear film breakup time (TBUT), corneal staining score (0–15), and Schirmer’s test results were included as objective metrics, whereas the Ocular Surface Disease Index (OSDI) questionnaire was administered to assess symptoms. Total OSDI score, vision-related subscore (derived from questions about vision and task performance), and discomfort-related subscore (derived from questions about ocular surface discomfort) were calculated for each subject. Results Seventy-five percent (48/64) of glaucoma subjects and 41% (24/59) of glaucoma suspects were receiving topical medications. The corneal staining grade was greater in glaucoma subjects than in glaucoma suspects (6.4 vs. 4.1; P<0.001), but groups did not differ with regard to TBUT or Schirmer’s results (P>0.20 for both). Multivariate regression models showed that topical glaucoma therapy burden was associated with a significantly higher total corneal staining grade (β, +0.9 for each additional glaucoma drop; 95% confidence interval [CI], 0.5–1.3; P<0.001), but not with TBUT or Schirmer’s results (P>0.20 for both). Glaucoma subjects had significantly higher total OSDI scores than glaucoma suspects (16.7 vs. 7.9; P<0.001). This largely was the result of higher vision-related subscores in the glaucoma group (11.1 vs. 3.3; P<0.001). Ocular discomfort–related subscores, however, were similar in both groups (5.7 vs. 4.6; P = 0.30). In multivariate analyses, each 5-decibel decrement in better-eye VF mean deviation was associated with a 4.7-point increase in total OSDI score (95% CI, 1.9–7.5; P = 0.001) and a 3.7-point increase in the vision-related subscore (95% CI, 1.7–5.6; P<0.001) but did not predict a higher discomfort-related subscore (β, 1.1 point; P = 0.07). Topical glaucoma therapy burden was not associated with higher total OSDI score or vision- or discomfort-related subscore (P>0.20 for all). Conclusions Glaucoma is associated with significant ocular surface disease, and topical glaucoma therapy burden seems predictive of corneal staining severity. However, OSDI is a poor metric for capturing ocular surface disease in glaucoma because symptoms seem to be related largely to VF loss. PMID:23714318

  11. Stability and in vitro toxicity of an infliximab eye drop formulation.

    PubMed

    Robert, Marie-Claude; Spurr-Michaud, Sandra; Frenette, Mathieu; Young, David; Gipson, Ilene K; Dohlman, Claes H

    2014-01-01

    The purpose of this study was to develop a novel 10-mg/mL infliximab eye drop, to characterize its physical and biological stability under recommended storage conditions, and to assess the formulation's toxicity to ocular surface epithelium in vitro. Infliximab (10 mg/mL) was reconstituted using equal volumes of sterile water and 1% carboxymethylcellulose artificial tears. Aliquots were stored in either a 4 degrees C refrigerator or -20 degrees C freezer for up to 45 days. Physical stability was assessed through monitoring the solution's appearance, pH, ultraviolet-visible-near infrared absorbance and scattering, as well as protein gel electrophoresis. Biological stability was assayed through binding to tumor necrosis factor-alpha using an enzyme-linked immunosorbent assay. In vitro cytotoxicity to human corneal-limbal epithelial cells was examined following a 4-hour exposure to the study drug. Refrigerated and frozen infliximab eye drops remained clear and colorless for the duration of study. The formulation's pH (7.0) was comparable to that of the artificial tear vehicle alone. Low levels of ultraviolet-visible-near infrared light absorbance and scattering established the lack of protein precipitate after refrigeration or freezing. Protein gel electrophoresis performed under reducing conditions revealed the presence of two main protein bands of approximately 50 kDa and 25 kDa, representing immunoglobulin G heavy and light chains. The migration pattern of the proteins did not change under the different storage conditions and between day 10 and 45 after formulation. Infliximab binding to tumor necrosis factor-alpha remained stable for up to 45 days, with conservation of 101% and 102% of its initial binding activity when refrigerated or frozen, respectively. In vitro human corneal-limbal epithelial cultures showed no increase in cytotoxicity with infliximab treatment when compared to vehicle and culture media controls (P > 0.05). Infliximab can be formulated as an eye drop and remains stable when stored in accordance with current regulations regarding compounded eye drops. The demonstrated physical and biological stability as well as in vitro innocuity of this infliximab eye drop formulation may facilitate future clinical investigation targeting tumor necrosis factor-alpha as a modulator of various ocular surface diseases.

  12. Microbial Keratitis: Could Contact Lens Material Affect Disease Pathogenesis?

    PubMed Central

    Evans, David J.; Fleiszig, Suzanne M. J.

    2012-01-01

    Microbial keratitis is a sight-threatening complication associated with contact lenses. The introduction of silicone hydrogel lens materials with increased oxygen transmission to the ocular surface has not significantly altered the incidence of microbial keratitis. These data suggest that alternate, or additional, predisposing factors involving lens wear must be addressed to reduce or eliminate these infections. The contact lens can provide a surface for microbial growth in situ, and can also influence ocular surface homeostasis through effects on the tear fluid and corneal epithelium. Thus, it is intuitive that future contact lens materials could make a significant contribution to preventing microbial keratitis. Design of the “right” material to prevent microbial keratitis requires understanding the effects of current materials on bacterial virulence in the cornea, and on ocular surface innate defenses. Current knowledge in each of these areas will be presented, with a discussion of future directions needed to understand the influence of lens material on the pathogenesis of microbial keratitis. PMID:23266587

  13. Lacritin and Other New Proteins of the Lacrimal Functional Unit

    PubMed Central

    McKown, Robert L.; Wang, Ningning; Raab, Ronald W.; Karnati, Roy; Zhang, Yinghui; Williams, Patricia B.; Laurie, Gordon W.

    2009-01-01

    The lacrimal functional unit (LFU) is defined by the 2007 International Dry Eye WorkShop as ‘an integrated system comprising the lacrimal glands, ocular surface (cornea, conjunctiva and meibomian glands) and lids, and the sensory and motor nerves that connect them’. The LFU maintains a healthy ocular surface primarily through a properly functioning tear film that provides protection, lubrication, and an environment for corneal epithelial cell renewal. LFU cells express thousands of proteins. Over two hundred new LFU proteins have been discovered in the last decade. Lacritin is a new LFU-specific growth factor in human tears that flows through ducts to target corneal epithelial cells on the ocular surface. When applied topically in rabbits, lacritin appears to increase the volume of basal tear secretion. Lacritin is one of only a handful of tear proteins preliminarily reported to be downregulated in blepharitis and in two dry eye syndromes. Computational analysis predicts an ordered C-terminal domain that binds the corneal epithelial cell surface proteoglycan syndecan-1 (SDC1) and is required for lacritin’s low nanomolar mitogenic activity. The lacritin binding site on the N-terminus of SDC1 is exposed by heparanase. Heparanase is constitutively expressed by the corneal epithelium and appears to be a normal constituent of tears. Binding triggers rapid signaling to downstream NFAT and mTOR. A wealth of other new proteins, originally designated as hypothetical when first identified by genomic sequencing, are expressed by the human LFU including: ALS2CL, ARHGEF19, KIAA1109, PLXNA1, POLG, WIPI1 and ZMIZ2. Their demonstrated or implied roles in human genetic disease or basic cellular functions are fuel for new investigation. Addressing topical areas in ocular surface physiology with new LFU proteins may reveal interesting new biological mechanisms and help get to the heart of ocular surface dysfunction. PMID:18840430

  14. Efficacy of a New Ocular Surface Modulator in Restoring Epithelial Changes in an In Vitro Model of Dry Eye Syndrome.

    PubMed

    Barabino, Stefano; De Servi, Barbara; Aragona, Salvatore; Manenti, Demetrio; Meloni, Marisa

    2017-03-01

    So far tear substitutes have demonstrated a limited role in restoring ocular surface damage in dry eye syndrome (DES). The aim of this study was to assess the efficacy of a new ocular surface modulator in an in vitro model of human corneal epithelium (HCE) damaged by severe osmotic stress mirroring the features of dry eye conditions. A reconstructed HCE model challenged by the introduction of sorbitol in the culture medium for 16 h was used to induce an inflammatory pathway and to impair the tight junctions integrity determining a severe modification of the superficial layer ultrastructure. At the end of the overnight stress period in the treated HCE series, 30 μl of the ocular surface modulator (T-LysYal, Sildeha, Switzerland) and of hyaluronic acid (HA) in the control HCE series were applied for 24 h. The following parameters were quantified: scanning electron microscopy (SEM), trans-epithelial electrical resistance (TEER), immunofluorescence analysis of integrin β1 (ITG-β1), mRNA expression of Cyclin D-1 (CCND1), and ITG-β1. In the positive control after the osmotic stress the HCE surface damage was visible at the ultrastructural level with loss of cell-cell interconnections, intercellular matrix destruction, and TEER reduction. After 24 h of treatment with T-LysYal, HCE showed a significant improvement of the ultrastructural morphological organization and increased expression of ITG-β1 at the tissue level when compared to positive and control series. A significant increase of mRNA expression for ITG-β1 and CCND1 was shown in the HA-treated cells compared to T-LysYal. TEER measurement showed a significant reduction in all groups after 16 h without modifications after the treatment period. This study has shown the possibility of a new class of agents denominated ocular surface modulators to restore corneal cells damaged by dry eye conditions. Further in vivo studies are certainly necessary to confirm these results.

  15. Toxic keratopathy associated with abuse of low-dose anesthetic: a case report.

    PubMed

    Chen, Hsiao-Ting; Chen, Ko-Hua; Hsu, Wen-Ming

    2004-07-01

    To describe the clinical course and treatment of toxic keratopathy associated with abuse of topical anesthetic at a very low concentration, 0.05%. Case report. A 47-year-old female systemic lupus erythematosus (SLE) patient with blurred vision and irritated right eye was referred to the ophthalmology department of our hospital. Under slit-lamp microscope, a 5.5 x 4.5 mm central corneal epithelial defect with underlying infiltrative and opaque stroma was noted in her right eye. Two weeks before, a corneal ulcer was diagnosed, and oxybuprocaine 0.05% (Lacrimin, Santen, Osaka, Japan) eye drops were prescribed 4 times daily but used every 5 to 10 minutes because the right eye was severely irritated. She was admitted immediately under the impression of toxic corneal ulcer. Preservative-free lubricants and prophylactic topical antibiotics 4 times daily were applied. Therapeutic soft contact lens was started after no infective agents were detected. Two weeks later, the stromal infiltration subsided, and the corneal epithelium was slowly healing, but superficial punctate epithelial defects at the lesion site persisted for another 6 months. The vision of her right eye improved from finger-counting at a 30-cm distance to 20/1200 with correction. Toxic keratopathy may result from abuse of topically administered anesthetics even at a very low concentration, 0.05%. Because this SLE patient has tear problems, we suggest that topical anesthetics must be used very cautiously and never prescribed to patients with dry eyes where the integrity of ocular surface is altered.

  16. Nanocarriers in ocular drug delivery: an update review.

    PubMed

    Wadhwa, Sheetu; Paliwal, Rishi; Paliwal, Shivani Rai; Vyas, S P

    2009-01-01

    Controlled drug delivery to eye is one of the most challenging fields of pharmaceutical research. Low drug-contact time and poor ocular bioavailability due to drainage of solution, tear turnover and its dilution or lacrimation are the problems associated with conventional systems. In addition, anatomical barriers and physiological conditions of eye are also important parameters which control designing of drug delivery systems. Nanosized carriers like micro/nano-suspensions, liposome, niosome, dendrimer, nanoparticles, ocular inserts, implants, hydrogels and prodrug approaches have been developed for this purpose. These novel systems offer manifold advantages over conventional systems as they increase the efficiency of drug delivery by improving the release profile and also reduce drug toxicity. Conventional delivery systems get diluted with tear, washed away through the lacrimal gland and usually require administering at regular time intervals whereas nanocarriers release drug at constant rate for a prolonged period of time and thus enhance its absorption and site specific delivery. This review presents an overview of the various aspects of the ocular drug delivery, with special emphasis on nanocarrier based strategies, including structure of eye, its barriers, delivery routes and the challenges/limitations associated with development of novel nanocarriers. The recent progresses in therapy of ocular disease like gene therapy have also been included so that future options should also be considered from the delivery point of view. Recent progress in the delivery of proteins and peptides via ocular route has also been incorporated for reader benefit.

  17. Implications for Ophthalmic Formulations: Ocular Buffers Show Varied Cytotoxic Impact on Human Corneal-Limbal and Human Conjunctival Epithelial Cells.

    PubMed

    Schuerer, Nadine; Stein, Elisabeth; Inic-Kanada, Aleksandra; Pucher, Marion; Hohenadl, Christine; Bintner, Nora; Ghasemian, Ehsan; Montanaro, Jacqueline; Barisani-Asenbauer, Talin

    2017-06-01

    To investigate toxicity associated with buffers commonly used in topical ocular drug formulations using a human corneal-limbal epithelial (HCLE) and a human conjunctival epithelial (HCjE) cell model. HCLE and HCjE cells were incubated for 10, 30, or 60 minutes with 4 different buffers based on borate, citrate, phosphate, and Tris-HCl at 10, 50, and 100 mM concentrations. To detect possible delayed effects on cell viability, after 60 minutes of buffer incubation, cells were further incubated for 24 hours with a cell medium. Cell viability was determined using a colorimetric XTT-based assay. The morphology of cells was also investigated. HCjE cells showed more sensitivity to buffer incubation than HCLE cells. The 100 mM phosphate buffer displayed significant delayed effects on cell viability of HCLE 16.8 ± 4.8% and HCjE 39.2 ± 6.1% cells after 60 minutes of exposure (P < 0.05). HCjE cell viability was reduced after 60 minutes incubations with 50 and 100 mM citrate buffer to 42.8 ± 6.5% and 39.3 ± 7.9%, respectively, and even lower percentages at the delayed time point (both P < 0.05). HCLE cell morphology was distinctly altered by 100 mM phosphate and Tris buffers after 30 minutes, whereas HCjE cells already showed marked changes after 10 minutes of exposure to 100 mM citrate and phosphate buffers. We observed a time-dependent decrease of viability in both HCLE and HCjE cells exposed to higher buffer concentrations. Therefore, we propose further in vivo studies to translate these finding to humans to discern the real effects of the buffer concentration in eye drops on the ocular surface.

  18. Implications for Ophthalmic Formulations: Ocular Buffers Show Varied Cytotoxic Impact on Human Corneal–Limbal and Human Conjunctival Epithelial Cells

    PubMed Central

    Schuerer, Nadine; Stein, Elisabeth; Inic-Kanada, Aleksandra; Pucher, Marion; Hohenadl, Christine; Bintner, Nora; Ghasemian, Ehsan; Montanaro, Jacqueline

    2017-01-01

    Purpose: To investigate toxicity associated with buffers commonly used in topical ocular drug formulations using a human corneal–limbal epithelial (HCLE) and a human conjunctival epithelial (HCjE) cell model. Methods: HCLE and HCjE cells were incubated for 10, 30, or 60 minutes with 4 different buffers based on borate, citrate, phosphate, and Tris-HCl at 10, 50, and 100 mM concentrations. To detect possible delayed effects on cell viability, after 60 minutes of buffer incubation, cells were further incubated for 24 hours with a cell medium. Cell viability was determined using a colorimetric XTT–based assay. The morphology of cells was also investigated. Results: HCjE cells showed more sensitivity to buffer incubation than HCLE cells. The 100 mM phosphate buffer displayed significant delayed effects on cell viability of HCLE 16.8 ± 4.8% and HCjE 39.2 ± 6.1% cells after 60 minutes of exposure (P < 0.05). HCjE cell viability was reduced after 60 minutes incubations with 50 and 100 mM citrate buffer to 42.8 ± 6.5% and 39.3 ± 7.9%, respectively, and even lower percentages at the delayed time point (both P < 0.05). HCLE cell morphology was distinctly altered by 100 mM phosphate and Tris buffers after 30 minutes, whereas HCjE cells already showed marked changes after 10 minutes of exposure to 100 mM citrate and phosphate buffers. Conclusions: We observed a time-dependent decrease of viability in both HCLE and HCjE cells exposed to higher buffer concentrations. Therefore, we propose further in vivo studies to translate these finding to humans to discern the real effects of the buffer concentration in eye drops on the ocular surface. PMID:28399036

  19. The zebrafish eye—a paradigm for investigating human ocular genetics

    PubMed Central

    Richardson, R; Tracey-White, D; Webster, A; Moosajee, M

    2017-01-01

    Although human epidemiological and genetic studies are essential to elucidate the aetiology of normal and aberrant ocular development, animal models have provided us with an understanding of the pathogenesis of multiple developmental ocular malformations. Zebrafish eye development displays in depth molecular complexity and stringent spatiotemporal regulation that incorporates developmental contributions of the surface ectoderm, neuroectoderm and head mesenchyme, similar to that seen in humans. For this reason, and due to its genetic tractability, external fertilisation, and early optical clarity, the zebrafish has become an invaluable vertebrate system to investigate human ocular development and disease. Recently, zebrafish have been at the leading edge of preclinical therapy development, with their amenability to genetic manipulation facilitating the generation of robust ocular disease models required for large-scale genetic and drug screening programmes. This review presents an overview of human and zebrafish ocular development, genetic methodologies employed for zebrafish mutagenesis, relevant models of ocular disease, and finally therapeutic approaches, which may have translational leads in the future. PMID:27612182

  20. Development of infrared thermal imager for dry eye diagnosis

    NASA Astrophysics Data System (ADS)

    Chiang, Huihua Kenny; Chen, Chih Yen; Cheng, Hung You; Chen, Ko-Hua; Chang, David O.

    2006-08-01

    This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.

  1. Oxygen Toxicity and Special Operations Forces Diving: Hidden and Dangerous

    PubMed Central

    Wingelaar, Thijs T.; van Ooij, Pieter-Jan A. M.; van Hulst, Rob A.

    2017-01-01

    In Special Operations Forces (SOF) closed-circuit rebreathers with 100% oxygen are commonly utilized for covert diving operations. Exposure to high partial pressures of oxygen (PO2) could cause damage to the central nervous system (CNS) and pulmonary system. Longer exposure time and higher PO2 leads to faster development of more serious pathology. Exposure to a PO2 above 1.4 ATA can cause CNS toxicity, leading to a wide range of neurologic complaints including convulsions. Pulmonary oxygen toxicity develops over time when exposed to a PO2 above 0.5 ATA and can lead to inflammation and fibrosis of lung tissue. Oxygen can also be toxic for the ocular system and may have systemic effects on the inflammatory system. Moreover, some of the effects of oxygen toxicity are irreversible. This paper describes the pathophysiology, epidemiology, signs and symptoms, risk factors and prediction models of oxygen toxicity, and their limitations on SOF diving. PMID:28790955

  2. Surgical Reconstruction of Ocular Surface Tumors Using Fibrin Sealant Tissue Adhesive.

    PubMed

    Queiroz de Paiva, Aline Roseane; Abreu de Azevedo Fraga, Larissa; Torres, Virgínia Laura Lucas

    2016-10-01

    To evaluate the surgical outcomes of ocular surface reconstruction in corneal-conjunctival tumors using fibrin tissue adhesive. A prospective noncomparative study was performed between May 2013 and February 2015. Patients were submitted to routine surgical procedure for corneal-conjunctival tumor excision followed by amniotic membrane graft transplantation using fibrin tissue adhesive (Evicel®, Omrix Biopharmaceuticals Ltd., Israel). Results were assessed on the 1st, 7th, 15th and 30th postoperative days to analyze subjective complaints, adhesiveness and positioning of the graft, potential complications and recurrences. Twenty-five eyes were analyzed (male, 14). The diagnosis after the treatment was categorized as squamous cell neoplasia, dysplasia, actinic keratosis, squamous papilloma and compound melanocytic nevus. Few significant symptoms were reported, such as mild hyperemia and ocular dyscomfort. One case developed a conjunctival granuloma which regressed after topical treatment. All grafts were successful with no displacements or retraction postoperatively. There was no clinical recurrence of the tumor in a mean time of follow-up of 11 months. Fibrin tissue adhesive is safe and effective in the surgery of ocular surface tumor. In this series, sutureless amniotic membrane transplantation using fibrin glue has the potential to shorten the surgical time, mitigate inflammation postoperatively and improve patient discomfort.

  3. Development of a Computational (in silico) Model of Ocular Teratogenesis

    EPA Science Inventory

    EPA’s ToxCast™ project is profiling the in vitro bioactivity of chemical compounds to assess pathway-level and cell-based signatures that are highly correlated with observed in vivo toxicity. In silico models provide a framework for interpreting the in vitro results and for simul...

  4. Chronic dry eye in PRK and LASIK: manifestations, incidence and predictive factors

    PubMed Central

    Bower, Kraig S.; Sia, Rose K.; Ryan, Denise S.; Mines, Michael J.; Dartt, Darlene A.

    2017-01-01

    Purpose To evaluate dry eye manifestations following photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) and determine the incidence and predictive factors of chronic dry eye using a set of dry eye criteria. Setting Walter Reed Army Medical Center, Washington, DC, USA Methods This is a prospective non-randomized clinical study of 143 active duty U.S. Army personnel aged 29.9±5.2 years with myopia or myopic astigmatism (manifest spherical equivalent −3.83±1.96 diopters) undergoing either PRK or LASIK. Dry eye evaluation was performed pre- and postoperatively. Main outcome measures included dry eye manifestations, incidence, and predictive factors of chronic dry eye. Results Schirmer scores, corneal sensitivity, ocular surface staining, surface regularity index (SRI), and responses to dry eye questionnaire significantly changed over time after PRK. After LASIK, significant changes were observed in tear breakup time, corneal sensitivity, ocular surface staining, and responses to questionnaire. At twelve months postoperatively, 5.0% of PRK and 0.8% of LASIK participants developed chronic dry eye. Regression analysis showed preoperatively lower Schirmer score will significantly influence development of chronic dry eye after PRK whereas preoperatively lower Schirmer score or higher ocular surface staining score will significantly influence the occurrence of chronic dry eye after LASIK. Conclusions Chronic dry eye is uncommon after PRK and LASIK. Ocular surface and tear film characteristics during preoperative examination may help predict chronic dry eye development in PRK and LASIK. PMID:26796443

  5. Clinical implications of mast cell involvement in allergic conjunctivitis.

    PubMed

    Elieh Ali Komi, D; Rambasek, T; Bielory, L

    2018-03-01

    The conjunctiva is a common site for the allergic inflammatory response due to it being highly vascularized, having constant exposure to environmental pollutants and allergenic pollens and having a unique conjunctival associated lymphoid tissue. The primary morbidity of anterior surface conjunctival disorders that include allergic conjunctivitis and tear film disorders is associated with its high frequency of involvement rather than its severity, although the more chronic forms can involve the cornea and lead to sight-threatening conditions. Ocular allergy is associated with IgE-mediated mast cell activation in conjunctival tissue leading to the release of preformed mediators including histamine and proteases and subsequent de novo formation of lipid-derived mediators and cytokines that trigger a cascade of cellular and molecular events leading to extensive migration and infiltration of inflammatory cells to the ocular surface. The trafficking of neutrophils, eosinophils, and lymphocytes to the ocular surface is due to establishing various chemokine gradients (mainly CCL11, CCL24, CCL5, MCP-3, and MCP-4), cell surface expression of adhesion molecules (such as VCAM-1 the ligand for VLA-4), and leukocyte adhesion to vascular endothelium. The release of preformed mediators underlies the acute ocular surface response while the secondary influx of inflammatory cells leading to the recruitment and activation of eosinophils and the subsequent activation of Th2 and Th1 lymphocytes at the level of the conjunctiva reflects the late-phase reaction. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  6. Alkali Burn of the Ocular Surface Associated With a Commonly Used Antifog Agent for Eyewear: Two Cases and a Review of Previous Reports.

    PubMed

    Welling, John D; Pike, Evan C; Mauger, Thomas F

    2016-02-01

    To report 2 cases of ocular chemical burns associated with the use of a swim goggle antifog agent and to review the literature for this and similar antifog products. Case reports and systematic review of the medical literature, material safety data, product safety reports, and consumer reviews. Two males, one 46 years and the other 41 years, were referred to our clinic with chemical burns of the ocular surface after using the same goggle antifog agent while swimming in a triathlon. Both sustained significant epithelial defects. Fortunately, with prompt treatment, both of our patients returned to their baseline vision within a few weeks without suffering sight-threatening complications. These are the first cases of ocular chemical burn secondary to use of an eyewear antifog agent to be reported in the medical literature. Similar reports found in consumer forums suggest that our cases are not isolated and these products may have the potential to cause vision-threatening chemical burns.

  7. Ocular chemical injuries and their management.

    PubMed

    Singh, Parul; Tyagi, Manoj; Kumar, Yogesh; Gupta, K K; Sharma, P D

    2013-05-01

    Chemical burns represent potentially blinding ocular injuries and constitute a true ocular emergency requiring immediate assessment and initiation of treatment. The majority of victims are young and exposure occurs at home, work place and in association with criminal assaults. Alkali injuries occur more frequently than acid injuries. Chemical injuries of the eye produce extensive damage to the ocular surface epithelium, cornea, anterior segment and limbal stem cells resulting in permanent unilateral or bilateral visual impairment. Emergency management if appropriate may be single most important factor in determining visual outcome. This article reviews the emergency management and newer techniques to improve the prognosis of patients with chemical injuries.

  8. In Vivo Confocal Microscopy of the Ocular Surface: From Bench to Bedside

    PubMed Central

    Villani, Edoardo; Baudouin, Christophe; Efron, Nathan; Hamrah, Pedram; Kojima, Takashi; Patel, Sanjay V.; Pflugfelder, Stephen C.; Zhivov, Andrey; Dogru, Murat

    2014-01-01

    In vivo confocal microscopy (IVCM) is an emerging technology that provides minimally invasive, high resolution, steady-state assessment of the ocular surface at the cellular level. Several challenges still remain but, at present, IVCM may be considered a promising technique for clinical diagnosis and management. This mini-review summarizes some key findings in IVCM of the ocular surface, focusing on recent and promising attempts to move “from bench to bedside”. IVCM allows prompt diagnosis, disease course follow-up, and management of potentially blinding atypical forms of infectious processes, such as acanthamoeba and fungal keratitis. This technology has improved our knowledge of corneal alterations and some of the processes that affect the visual outcome after lamellar keratoplasty and excimer keratorefractive surgery. In dry eye disease, IVCM has provided new information on the whole-ocular surface morphofunctional unit. It has also improved understanding of pathophysiologic mechanisms and helped in the assessment of prognosis and treatment. IVCM is particularly useful in the study of corneal nerves, enabling description of the morphology, density, and disease- or surgically induced alterations of nerves, particularly the subbasal nerve plexus. In glaucoma, IVCM constitutes an important aid to evaluate filtering blebs, to better understand the conjunctival wound healing process, and to assess corneal changes induced by topical antiglaucoma medications and their preservatives. IVCM has significantly enhanced our understanding of the ocular response to contact lens wear. It has provided new perspectives at a cellular level on a wide range of contact lens complications, revealing findings that were not previously possible to image in the living human eye. The final section of this mini-review provides a focus on advances in confocal microscopy imaging. These include 2D wide-field mapping, 3D reconstruction of the cornea and automated image analysis. PMID:24215436

  9. Co-ordinated ocular development from human iPS cells and recovery of corneal function.

    PubMed

    Hayashi, Ryuhei; Ishikawa, Yuki; Sasamoto, Yuzuru; Katori, Ryosuke; Nomura, Naoki; Ichikawa, Tatsuya; Araki, Saori; Soma, Takeshi; Kawasaki, Satoshi; Sekiguchi, Kiyotoshi; Quantock, Andrew J; Tsujikawa, Motokazu; Nishida, Kohji

    2016-03-17

    The eye is a complex organ with highly specialized constituent tissues derived from different primordial cell lineages. The retina, for example, develops from neuroectoderm via the optic vesicle, the corneal epithelium is descended from surface ectoderm, while the iris and collagen-rich stroma of the cornea have a neural crest origin. Recent work with pluripotent stem cells in culture has revealed a previously under-appreciated level of intrinsic cellular self-organization, with a focus on the retina and retinal cells. Moreover, we and others have demonstrated the in vitro induction of a corneal epithelial cell phenotype from pluripotent stem cells. These studies, however, have a single, tissue-specific focus and fail to reflect the complexity of whole eye development. Here we demonstrate the generation from human induced pluripotent stem cells of a self-formed ectodermal autonomous multi-zone (SEAM) of ocular cells. In some respects the concentric SEAM mimics whole-eye development because cell location within different zones is indicative of lineage, spanning the ocular surface ectoderm, lens, neuro-retina, and retinal pigment epithelium. It thus represents a promising resource for new and ongoing studies of ocular morphogenesis. The approach also has translational potential and to illustrate this we show that cells isolated from the ocular surface ectodermal zone of the SEAM can be sorted and expanded ex vivo to form a corneal epithelium that recovers function in an experimentally induced animal model of corneal blindness.

  10. Sleep and mood disorders in dry eye disease and allied irritating ocular diseases.

    PubMed

    Ayaki, Masahiko; Kawashima, Motoko; Negishi, Kazuno; Kishimoto, Taishiro; Mimura, Masaru; Tsubota, Kazuo

    2016-03-01

    The aim of the present study was to evaluate sleep and mood disorders in patients with irritating ocular diseases. The study design was a cross-sectional/case-control study conducted in six eye clinics. Out of 715 outpatients diagnosed with irritating ocular surface diseases and initially enrolled, 301 patients with dry eye disease (DED) and 202 age-matched control participants with other ocular surface diseases were analyzed. The mean Pittsburgh Sleep Quality Index (PSQI) and Hospital Anxiety and Depression Scale (HADS) scores were 6.4 ± 3.2 and 11.1 ± 5.7 for severe DED (n = 146), 5.5 ± 3.3 and 9.8 ± 4.0 for mild DED (n = 155), 5.5 ± 3.1 and 9.5 ± 6.6 for chronic conjunctivitis (n = 124), and 5.0 ± 3.3 and 8.9 ± 5.3 for allergic conjunctivitis (n = 78). There were significant differences among these diagnostic groups for PSQI (P < 0.05). Regression analysis of patients with DED revealed the PSQI and HADS scores were significantly correlated with the severity of DED (P < 0.05). Our results demonstrate that sleep quality in patients with DED is significantly worse than in patients with other irritating ocular surface diseases and it is correlated with the severity of DED.

  11. Episcleral, intrascleral, and suprachoroidal routes of ocular drug delivery - recent research advances and patents.

    PubMed

    Gilger, Brian C; Mandal, Abhirup; Shah, Sujay; Mitra, Ashim K

    2014-01-01

    Subconjunctival/episcleral, intrascleral, and suprachoroidal routes of drug delivery for treatment of posterior segment eye diseases have become more feasible and popular in the past few years. These routes have the advantage of bypassing the main barriers to topical drug penetration, the ocular surface epithelium, the conjunctivallymphatics, and in the case of deep intrascleral and suprachoroidial delivery, the sclera barrier. Many ocular drug delivery application devices, drug delivery methods, and therapeutics that have been developed for intravitreal use can also be used subconjunctivally, intrasclerally, and in the suprachoroidal space. Alternatively, site-specific devices, such microneedles, and therapeutics, such as hydrogel matrices, have been developed to enhance ocular drug delivery. This manuscript will review the recent research advances and patents on episcleral, intrascleral, and suprachoroidal routes of ocular drug delivery.

  12. Nontuberculous Mycobacterial Ocular Infections: A Systematic Review of the Literature

    PubMed Central

    Kheir, Wajiha J.; Sheheitli, Huda; Abdul Fattah, Maamoun; Hamam, Rola N.

    2015-01-01

    Nontuberculous or atypical mycobacterial ocular infections have been increasing in prevalence over the past few decades. They are known to cause periocular, adnexal, ocular surface and intraocular infections and are often recalcitrant to medical therapy. These infections can potentially cause detrimental outcomes, in part due to a delay in diagnosis. We review 174 case reports and series on nontuberculous mycobacterial (NTM) ocular infections and discuss etiology, microbiology, risk factors, diagnosis, clinical presentation, and treatment of these infections. History of interventions, trauma, foreign bodies, implants, contact lenses, and steroids are linked to NTM ocular infections. Steroid use may prolong the duration of the infection and cause poorer visual outcomes. Early diagnosis and initiation of treatment with multiple antibiotics are necessary to achieve the best visual outcome. PMID:26106601

  13. Corneal Epitheliopathy After Trauma by Fake Snow Powder in a 7-year-old Child

    PubMed Central

    Al-Amry, Mohammad A.; Al-Ghadeer, Huda A.

    2016-01-01

    Fake snow is a polymer of sodium polyacrylates used in games and celebrations. Despite the product leaflet that indicates safety, contact with the ocular surface can cause injury. We report a case of a child with corneal epitheliopathy due to a chemical burn injury after ocular surface contact with fake snow. The case was managed with epithelial debridement and a bandage contact lenses and topical antibiotics with complete resolution. PMID:27555717

  14. Development of Causative Treatment Strategies for Lacrimal Gland Insufficiency by Tissue Engineering and Cell Therapy. Part 2: Reconstruction of Lacrimal Gland Tissue: What Has Been Achieved So Far and What Are the Remaining Challenges?

    PubMed

    Massie, Isobel; Dietrich, Jana; Roth, Mathias; Geerling, Gerd; Mertsch, Sonja; Schrader, Stefan

    2016-10-01

    The lacrimal gland is located in the upper temporal compartment of the orbita, and along with the ocular surface, eye lids, and sensory and motor nerves forms the lacrimal functional unit (LFU). The LFU is responsible for producing, distributing, and maintaining the tear film in order to maintain a smooth, moist, and regular ocular surface epithelium such that appropriate refractive properties are achieved and the eyeball is protected against dust, debris, and pathogens. If the main lacrimal gland is impaired (due to either disease or injury), this balance is disrupted, and severe quantitative dry eye syndrome (DES) can develop. DES treatments remain palliative, with the most commonly used therapies being based on tear substitution, tear retention, and control of inflammation on the ocular surface. Causative treatments such as salivary gland transplantation have shown to reduce symptoms in very severe cases, however can cause problems on the ocular surface due to different properties of saliva and tears. Therefore, causative approaches for treating DES by regeneration or reconstruction of lacrimal gland tissue depending on disease severity seem highly appealing. This article reviews current approaches for in vitro reconstruction of lacrimal gland tissue. Finally, the limitations that must be overcome before a new, tissue-engineered therapy may be delivered to clinic will be discussed.

  15. α-Melanocyte-stimulating hormone ameliorates ocular surface dysfunctions and lesions in a scopolamine-induced dry eye model via PKA-CREB and MEK-Erk pathways.

    PubMed

    Ru, Yusha; Huang, Yue; Liu, Huijuan; Du, Juan; Meng, Zhu; Dou, Zexia; Liu, Xun; Wei, Rui Hua; Zhang, Yan; Zhao, Shaozhen

    2015-12-21

    Dry eye is a highly prevalent, chronic, and multifactorial disease that compromises quality of life and generates socioeconomic burdens. The pathogenic factors of dry eye disease (DED) include tear secretion abnormalities, tear film instability, and ocular surface inflammation. An effective intervention targeting the pathogenic factors is needed to control this disease. Here we applied α-Melanocyte-stimulating hormone (α-MSH) twice a day to the ocular surface of a scopolamine-induced dry eye rat model. The results showed that α-MSH at different doses ameliorated tear secretion, tear film stability, and corneal integrity, and corrected overexpression of proinflammatory factors, TNF-α, IL-1β, and IFN-γ, in ocular surface of the dry eye rats. Moreover, α-MSH, at 10(-4) μg/μl, maintained corneal morphology, inhibited apoptosis, and restored the number and size of conjunctival goblet cells in the dry eye rats. Mechanistically, α-MSH activated both PKA-CREB and MEK-Erk pathways in the dry eye corneas and conjunctivas; pharmacological blockade of either pathway abolished α-MSH's protective effects, suggesting that both pathways are necessary for α-MSH's protection under dry eye condition. The peliotropic protective functions and explicit signaling mechanism of α-MSH warrant translation of the α-MSH-containing eye drop into a novel and effective intervention to DED.

  16. Xenogeneic Acellular Conjunctiva Matrix as a Scaffold of Tissue-Engineered Corneal Epithelium

    PubMed Central

    Zhao, Haifeng; Qu, Mingli; Wang, Yao; Wang, Zhenyu; Shi, Weiyun

    2014-01-01

    Amniotic membrane-based tissue-engineered corneal epithelium has been widely used in the reconstruction of the ocular surface. However, it often degrades too early to ensure the success of the transplanted corneal epithelium when treating patients with severe ocular surface disorders. In the present study, we investigated the preparation of xenogeneic acellular conjunctiva matrix (aCM) and evaluated its efficacy and safety as a scaffold of tissue-engineered corneal epithelium. Native porcine conjunctiva was decellularized with 0.1% sodium dodecyl sulfate (SDS) for 12 h at 37°C and sterilized via γ-irradiation. Compared with native conjunctiva, more than 92% of the DNA was removed, and more than 90% of the extracellular matrix components (glycosaminoglycan and collagen) remained after the decellularization treatment. Compared with denuded amniotic membrane (dAM), the aCM possessed favorable optical transmittance, tensile strength, stability and biocompatibility as well as stronger resistance to degradation both in vitro and in vivo. The corneal epithelial cells seeded on aCM formed a multilayered epithelial structure and endured longer than did those on dAM. The aCM-based tissue-engineered corneal epithelium was more effective in the reconstruction of the ocular surface in rabbits with limbal stem cell deficiency. These findings support the application of xenogeneic acellular conjunctiva matrix as a scaffold for reconstructing the ocular surface. PMID:25375996

  17. α-Melanocyte-stimulating hormone ameliorates ocular surface dysfunctions and lesions in a scopolamine-induced dry eye model via PKA-CREB and MEK-Erk pathways

    PubMed Central

    Ru, Yusha; Huang, Yue; Liu, Huijuan; Du, Juan; Meng, Zhu; Dou, Zexia; Liu, Xun; Wei, Rui Hua; Zhang, Yan; Zhao, Shaozhen

    2015-01-01

    Dry eye is a highly prevalent, chronic, and multifactorial disease that compromises quality of life and generates socioeconomic burdens. The pathogenic factors of dry eye disease (DED) include tear secretion abnormalities, tear film instability, and ocular surface inflammation. An effective intervention targeting the pathogenic factors is needed to control this disease. Here we applied α-Melanocyte-stimulating hormone (α-MSH) twice a day to the ocular surface of a scopolamine-induced dry eye rat model. The results showed that α-MSH at different doses ameliorated tear secretion, tear film stability, and corneal integrity, and corrected overexpression of proinflammatory factors, TNF-α, IL-1β, and IFN-γ, in ocular surface of the dry eye rats. Moreover, α-MSH, at 10−4 μg/μl, maintained corneal morphology, inhibited apoptosis, and restored the number and size of conjunctival goblet cells in the dry eye rats. Mechanistically, α-MSH activated both PKA-CREB and MEK-Erk pathways in the dry eye corneas and conjunctivas; pharmacological blockade of either pathway abolished α-MSH’s protective effects, suggesting that both pathways are necessary for α-MSH’s protection under dry eye condition. The peliotropic protective functions and explicit signaling mechanism of α-MSH warrant translation of the α-MSH-containing eye drop into a novel and effective intervention to DED. PMID:26685899

  18. Effects of the rigid gas permeable contact lense use on tear and ocular surface among keratoconus patients.

    PubMed

    Yuksel Elgin, Cansu; Iskeleli, Guzin; Aydin, Ovgu

    2018-06-01

    To investigate changes in tear and ocular surface of patients with keratoconus using rigid gas permeable contact lenses (RGPCL) and compare them against keratoconus patients who were not using lenses as well as a control group of healthy subjects. 24 keratoconus patients using RGPCL (Group 1) 22 patients who were not using lenses (Group 3) and 21 healthy subjects (Group 3) were included in the study. Subjective complaints about the subjects' eyes have been investigated using the ocular-surface disease index (OSDI). After the control of best-corrected visual acuity, anterior chamber and fundus examinations were performed. Schirmer (p-value=0.01) and tear break up mean comparison tests (p-value=0.002) revealed significant differences across different groups but tear osmolarity analysis did not (p-value >0.05). Oxford and OSDI scores were compatible with Schirmer and tear break up test comparisons. (for both p-value=0.001) Moreover, no statistical differences were seen in impression cytology measures between groups. (p-value >0.05) CONCLUSIONS: The erosion in the tear film stability is in line with the erosion in the ocular surface epithelium. Taking into account the statistical indifference between the impression cytology measures across groups, the break up time differences may be attributed to the collagen destruction in tear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Treatment of ocular rosacea: comparative study of topical cyclosporine and oral doxycycline.

    PubMed

    Arman, Aysegul; Demirseren, Duriye Deniz; Takmaz, Tamer

    2015-01-01

    To compare the effectiveness of topical cyclosporine A emulsion with that of oral doxycycline for rosacea associated ocular changes and dry eye complaints. One hundred and ten patients with rosacea were screened. Thirty-eight patients having rosacea associated eyelid and ocular surface changes and dry eye complaints were included in the study. Patients were randomly divided into two groups: nineteen patients were given topical cyclosporine twice daily and nineteen patients were given oral doxycycline 100 mg twice daily for the first month and once daily for the following two months. Symptom and sign scores, ocular surface disease index questionnarie and tear function tests were evaluated at baseline and monthly for 3mo. Three months after results were compared with that of baseline. Mean values of symptom, eyelid sign and corneal/conjunctival sign scores of each treatment group at baseline and 3mo after treatments were compared and both drugs were found to be effective on rosacea associated ocular changes (P<0.001). Cyclosporine was more effective in symptomatic relief and in the treatment of eyelid signs (P=0.01). There was statistically significant increase in the mean Schirmer score with anesthesia and tear break up time scores in the cyclosporine treatment group compared to the doxycycline treatment group (P<0.05). Cyclosporine as a topical drug can be used in the treatment of rosacea associated ocular complications because it is more effective than doxycycline. In addition ocular rosacea as a chronic disease requires long term treatment and doxycycline has various side effects limiting its long term usage.

  20. Dosage variability of topical ocular hypotensive products: a densitometric assessment.

    PubMed

    Gaynes, Bruce I; Singa, Ramesh M; Cao, Ying

    2009-02-01

    To ascertain consequence of variability in drop volume obtained from multiuse topical ocular hypotensive products in terms of uniformity of product dosage. Densitometric assessment of drop volume dispensed from 2 alternative bottle positions. All except one product demonstrated a statistically significant difference in drop volume when administered at either a 45-degree or 90-degree bottle angle (Student t test, P<0.001). Product-specific drop volume ranged from a nadir of 22.36 microL to a high of 53.54 microL depending on bottle angle of administration. Deviation in drop dose was directly proportional to variability in drop volume. Variability in per drop dosage was conspicuous among products with a coefficient of variation from 1.49% to 15.91%. In accordance with drop volume, all products demonstrated a statistically significant difference in drop dose at 45-degree versus 90-degree administration angles. Drop volume was found unrelated to drop uniformity (Spearman r=0.01987 and P=0.9463). Variability and lack of uniformity in drop dosage is clearly evident among select ocular hypotensive products and is related to angle of drop administration. Erratic dosage of topical ocular hypotensive therapy may contribute in part to therapeutic failure and/or toxicity.

  1. The effects of 2% rebamipide ophthalmic solution on the tear functions and ocular surface of the superoxide dismutase-1 (sod1) knockout mice.

    PubMed

    Ohguchi, Takeshi; Kojima, Takashi; Ibrahim, Osama M; Nagata, Taeko; Shimizu, Takahiko; Shirasawa, Takuji; Kawakita, Tetsuya; Satake, Yoshiyuki; Tsubota, Kazuo; Shimazaki, Jun; Ishida, Susumu

    2013-11-21

    To investigate the efficacy of 2% rebamipide ophthalmic solution on the tear functions and ocular surface status of the superoxide dismutase-1(Sod1(-/-)) mice. Two percent Rebamipide ophthalmic solution was applied to 40-week-old male Sod1(-/-) and wild-type (WT) mice four times a day for 2 weeks. We examined the cytokine concentrations in the tear fluid (by CytoBead assay), tear film break-up time, amount of tear production, and expressions of mucins 1, 4, and 5AC, by RT-PCR. We also performed vital staining of the ocular surface, PAS staining for muc5AC, and immunohistochemical stainings for 4-hydroxy-2-nonenal (4-HNE), 8-hydroxy-2'-deoxyguanosine (8-OHdG), in the conjunctiva to compare the results before and after rebamipide instillations. The tear functions and ocular surface epithelial damage scores were significantly worse in the Sod1(-/-) than in the WT mice. Application of 2% rebamipide for 2 weeks significantly improved the tear film break-up time, the amount of tear production, and the corneal epithelial damage scores, which also significantly increased the conjunctival goblet cell density and muc5 mRNA expression, in the Sod1(-/-) mice. The mean IL-6, IL-17, TNF-α, and IFN-γ levels in the tear fluid were reduced significantly along with a significant decrease in the density of cells positive for 4-HNE and 8-OHdG in the conjunctiva. Two percent Rebamipide ophthalmic solution significantly improved the tear stability and corneal epithelial damage, and enhanced the expression of muc5 mRNA on the ocular surface. We also observed anti-inflammatory effects in the tear film together with antioxidative effects in the conjunctiva, suggesting the efficacy of rebamipide in age-related dry eye disease attributable to SOD1 knockout.

  2. Comparing the Effects of Particulate Matter on the Ocular Surfaces of Normal Eyes and a Dry Eye Rat Model.

    PubMed

    Han, Ji Yun; Kang, Boram; Eom, Youngsub; Kim, Hyo Myung; Song, Jong Suk

    2017-05-01

    To compare the effect of exposure to particulate matter on the ocular surface of normal and experimental dry eye (EDE) rat models. Titanium dioxide (TiO2) nanoparticles were used as the particulate matter. Rats were divided into 4 groups: normal control group, TiO2 challenge group of the normal model, EDE control group, and TiO2 challenge group of the EDE model. After 24 hours, corneal clarity was compared and tear samples were collected for quantification of lactate dehydrogenase, MUC5AC, and tumor necrosis factor-α concentrations. The periorbital tissues were used to evaluate the inflammatory cell infiltration and detect apoptotic cells. The corneal clarity score was greater in the EDE model than in the normal model. The score increased after TiO2 challenge in each group compared with each control group (normal control vs. TiO2 challenge group, 0.0 ± 0.0 vs. 0.8 ± 0.6, P = 0.024; EDE control vs. TiO2 challenge group, 2.2 ± 0.6 vs. 3.8 ± 0.4, P = 0.026). The tear lactate dehydrogenase level and inflammatory cell infiltration on the ocular surface were higher in the EDE model than in the normal model. These measurements increased significantly in both normal and EDE models after TiO2 challenge. The tumor necrosis factor-α levels and terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling-positive cells were also higher in the EDE model than in the normal model. TiO2 nanoparticle exposure on the ocular surface had a more prominent effect in the EDE model than it did in the normal model. The ocular surface of dry eyes seems to be more vulnerable to fine dust of air pollution than that of normal eyes.

  3. Expression of Lipid Peroxidation Markers in the Tear Film and Ocular Surface of Patients with Non-Sjogren Syndrome: Potential Biomarkers for Dry Eye Disease.

    PubMed

    Choi, Won; Lian, Cui; Ying, Li; Kim, Ga Eon; You, In Cheon; Park, Soo Hyun; Yoon, Kyung Chul

    2016-09-01

    To investigate the expression of lipid peroxidation markers in the tear film and ocular surface and their correlation with disease severity in patients with dry eye disease. The concentrations of hexanoyl-lysine (HEL), 4-hydroxy-2-nonenal (HNE), and malondialdehyde (MDA) were measured with enzyme-linked immunosorbent assays in tears obtained from 44 patients with non-Sjogren syndrome dry eye and 33 control subjects. The correlations between the marker levels and the tear film and ocular surface parameters, including tear film break-up time (BUT), Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, corneal sensitivity, conjunctival goblet cell density, and symptom score, were analyzed. The expression of the lipid peroxidation markers HEL, 4-HNE, and MDA in the conjunctiva was evaluated using immunohistochemistry. The concentrations of HEL, 4-HNE, and MDA were 279.84 ± 69.98 nmol/L, 0.02 ± 0.01 μg/mL, and 3.80 ± 1.05 pmol/mg in control subjects and 283.21 ± 89.67 nmol/L (p = 0.97), 0.20 ± 0.03 μg/mL (p < 0.01), and 13.32 ± 4.03 pmol/mg (p < 0.01) in dry eye patients. 4-HNE and MDA levels significantly correlated with BUT, Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, conjunctival goblet cell density, and symptom score (p < 0.05), whereas HEL levels did not correlate with these parameters. Staining intensities for 4-HNE and MDA increased in dry eye patients. The expression of late lipid peroxidation markers, 4-HNE and MDA, increases in the tear film and ocular surface of patients with dry eye. The levels correlate with various tear film and ocular surface parameters and may reflect the severity of dry eye disease.

  4. Corneal Expression of SLURP-1 by Age, Sex, Genetic Strain, and Ocular Surface Health

    PubMed Central

    Swamynathan, Sudha; Delp, Emili E.; Harvey, Stephen A. K.; Loughner, Chelsea L.; Raju, Leela; Swamynathan, Shivalingappa K.

    2015-01-01

    Purpose Although secreted Ly6/urokinase-type plasminogen activator receptor–related protein-1 (Slurp1) transcript is highly abundant in the mouse cornea, corresponding protein expression remains uncharacterized. Also, SLURP1 was undetected in previous tear proteomics studies, resulting in ambiguity about its baseline levels. Here, we examine mouse corneal Slurp1 expression in different sexes, age groups, strains, and health conditions, and quantify SLURP1 in human tears from healthy or inflamed ocular surfaces. Methods Expression of Slurp1 in embryonic day-13 (E13), E16, postnatal day-1 (PN1), PN10, PN20, and PN70 Balb/C, FVBN, C57Bl/6, and DBA/2J mouse corneas, Klf4Δ/ΔCE corneas with corneal epithelial–specific ablation of Klf4, migrating cells in wild-type corneal epithelial wound edge, and in corneas exposed to pathogen-associated molecular patterns (PAMPs) poly(I:C), zymosan-A, or Pam3Csk4 was examined by QPCR, immunoblots, and immunofluorescent staining. Human SLURP1 levels were quantified by ELISA in tears from 34 men and women aged 18 to 80 years. Results Expression of Slurp1, comparable in different strains and sexes, was low in E13, E16, PN1, and PN10 mouse corneas, and increased rapidly after eyelid opening in a Klf4-dependent manner. We found Slurp1 was downregulated in corneas exposed to PAMPs, and in migrating cells at the wound edge. Human SLURP1 expression, comparable in different sexes and age groups, was significantly decreased in tears from inflamed ocular surfaces (0.34%) than those from healthy individuals (0.77%). Conclusions These data describe the influence of age, sex, genetic background, and ocular surface health on mouse corneal expression of Slurp1, establish the baseline for human tear SLURP1 expression, and identify SLURP1 as a useful diagnostic and/or therapeutic target for inflammatory ocular surface disorders. PMID:26670825

  5. Comparative effect of lens care solutions on blink rate, ocular discomfort and visual performance.

    PubMed

    Yang, Shun-nan; Tai, Yu-chi; Sheedy, James E; Kinoshita, Beth; Lampa, Matthew; Kern, Jami R

    2012-09-01

    To help maintain clear vision and ocular surface health, eye blinks occur to distribute natural tears over the ocular surface, especially the corneal surface. Contact lens wearers may suffer from poor vision and dry eye symptoms due to difficulty in lens surface wetting and reduced tear production. Sustained viewing of a computer screen reduces eye blinks and exacerbates such difficulties. The present study evaluated the wetting effect of lens care solutions (LCSs) on blink rate, dry eye symptoms, and vision performance. Sixty-five adult habitual soft contact lens wearers were recruited to adapt to different LCSs (Opti-free, ReNu, and ClearCare) in a cross-over design. Blink rate in pictorial viewing and reading (measured with an eyetracker), dry eye symptoms (measured with the Ocular Surface Disease Index questionnaire), and visual discrimination (identifying tumbling E) immediately before and after eye blinks were measured after 2 weeks of adaption to LCS. Repeated measures anova and mixed model ancova were conducted to evaluate effects of LCS on blink rate, symptom score, and discrimination accuracy. Opti-Free resulted in lower dry eye symptoms (p = 0.018) than ClearCare, and lower spontaneous blink rate (measured in picture viewing) than ClearCare (p = 0.014) and ReNu (p = 0.041). In reading, blink rate was higher for ClearCare compared to ReNu (p = 0.026) and control (p = 0.024). Visual discrimination time was longer for the control (daily disposable lens) than for Opti-Free (p = 0.007), ReNu (p = 0.009), and ClearCare (0.013) immediately before the blink. LCSs differently affected blink rate, subjective dry eye symptoms, and visual discrimination speed. Those with wetting agents led to significantly fewer eye blinks while affording better ocular comfort for contact lens wearers, compared to that without. LCSs with wetting agents also resulted in better visual performance compared to wearing daily disposable contact lenses. These presumably are because of improved tear film quality. © 2012 The College of Optometrists.

  6. Incorporation of liquid lipid in lipid nanoparticles for ocular drug delivery enhancement

    NASA Astrophysics Data System (ADS)

    Shen, Jie; Sun, Minjie; Ping, Qineng; Ying, Zhi; Liu, Wen

    2010-01-01

    The present work investigates the effect of liquid lipid incorporation on the physicochemical properties and ocular drug delivery enhancement of nanostructured lipid carriers (NLCs) and attempts to elucidate in vitro and in vivo the potential of NLCs for ocular drug delivery. The CyA-loaded or fluorescein-marked nanocarriers composed of Precifac ATO 5 and Miglyol 840 (as liquid lipid) were prepared by melting-emulsion technology, and the physicochemical properties of nanocarriers were determined. The uptake of nanocarriers by human corneal epithelia cell lines (SDHCEC) and rabbit cornea was examined. Ex vivo fluorescence imaging was used to investigate the ocular distribution of nanocarriers. The in vitro cytotoxicity and in vivo acute tolerance were evaluated. The higher drug loading capacity and improved in vitro sustained drug release behavior of lipid nanoparticles was found with the incorporation of liquid lipid in lipid nanoparticles. The uptake of nanocarriers by the SDHCEC was increased with the increase in liquid lipid loading. The ex vivo fluorescence imaging of the ocular tissues indicated that the liquid lipid incorporation could improve the ocular retention and penetration of ocular therapeutics. No alternation was macroscopically observed in vivo after ocular surface exposure to nanocarriers. These results indicated that NLC was a biocompatible and potential nanocarrier for ocular drug delivery enhancement.

  7. Genome-Wide Association Study of Entropion Eyelid in Multiple Breeds of Sheep

    USDA-ARS?s Scientific Manuscript database

    Entropion is an inversion of the eyelid margin causing lashes or external hairs to rub against the ocular surface. If uncorrected, discomfort, ocular damage, increased eye infection rates, and potential blindness can occur. Entropion affects many mammalian species, can be expressed in both upper and...

  8. Release of Membrane-associated Mucins from Ocular Surface Epithelia

    PubMed Central

    Blalock, Timothy D.; Spurr-Michaud, Sandra J.; Tisdale, Ann S.; Gipson, Ilene K.

    2008-01-01

    Purpose Three membrane-associated mucins (MAMs)—MUC1, MUC4 and MUC16—are expressed at the ocular surface epithelium. Soluble forms of MAMs are detected in human tears, but the mechanisms of their release from the apical cells are unknown. The purpose of this study was to identify physiologic agents that induce ocular surface MAM release. Methods An immortalized human corneal-limbal epithelial cell line (HCLE) expressing the same MAMs as native tissue was used. An antibody specific to MUC16’s cytoplasmic tail was developed to confirm that only the extracellular domain is released into the tear fluid or culture media. Effects of agents that have been shown to be present in tears or are implicated in release/shedding of MAMs in other epithelia (neutrophil elastase, tumor necrosis factor (TNF), TNF-α-converting enzyme, and matrix metalloproteinases-7 and –9) were assessed on HCLE cells. HCLE cell surface proteins were biotinylated to measure efficiency of induced MAM release and surface restoration. Effects of induced release on surface barrier function were measured by rose bengal dye penetrance. Results MUC16 in tears and in HCLE-conditioned medium lacked the cytoplasmic tail. TNF induced release of MUC1, MUC4, and MUC16 from the HCLE surface. Matrix metalloproteinase-7 and neutrophil elastase induced release of MUC16 but not MUC1 or MUC4. Neutrophil elastase removed 68% of MUC16—78% of which was restored to the HCLE cell surface 24 hours after release. Neutrophil elastase-treated HCLE cells showed significantly reduced rose bengal dye exclusion. Conclusions Results suggest that extracellular domains of MUC1, 4, and 16 can be released from the ocular surface by agents present in tears. Neutrophil elastase and TNF present in higher amounts in dry eye patients’ tears may cause MAM release—allowing rose bengal staining. PMID:18436821

  9. Dry eye disease: pathophysiology, classification, and diagnosis.

    PubMed

    Perry, Henry D

    2008-04-01

    Dry eye disease (DED) is a multifactorial disorder of the tear film and ocular surface that results in eye discomfort, visual disturbance, and often ocular surface damage. Although recent research has made progress in elucidating DED pathophysiology, currently there are no uniform diagnostic criteria. This article discusses the normal anatomy and physiology of the lacrimal functional unit and the tear film; the pathophysiology of DED; DED etiology, classification, and risk factors; and DED diagnosis, including symptom assessment and the roles of selected diagnostic tests.

  10. The Role of Medications in Causing Dry Eye

    PubMed Central

    Fraunfelder, Frederick T.; Sciubba, James J.; Mathers, William D.

    2012-01-01

    The purpose of this paper is to review the possible role of polypharmacy in causing dry eye disease (DED), reflecting the complex interactions and complications associated with the use of multiple systemic and topical ocular medications. The pharmacological, physiological, anatomical, and histological mechanisms causing dry mouth differ little from those causing dry eye. Oral polypharmacy is the most common cause of dry mouth, but has not been investigated as a cause of dry eye. Topical ocular polypharmacy has been shown to cause DED. Information on drugs that likely cause or aggravate DED and the controversial role of preservatives in topical ocular medications are examined. Systemic or topical ocular medications and preservatives used in topical ocular drugs may cause dry eye through the drug's therapeutic action, ocular surface effects, or preservatives, and the effects probably are additive. Long-term use of topical ocular medications, especially those containing preservatives such as BAK, may play an important role in DED and the role of polypharmacy needs further study. We review possible ways to decrease the risk of medication-related dry eye. PMID:23050121

  11. Differential effect of rebamipide on transmembrane mucin biosynthesis in stratified ocular surface epithelial cells.

    PubMed

    Uchino, Yuichi; Woodward, Ashley M; Argüeso, Pablo

    2016-12-01

    Mucins are a group of highly glycosylated glycoproteins responsible for the protection of wet-surfaced epithelia. Recent data indicate that transmembrane mucins differ in their contribution to the protective function of the ocular surface, with MUC16 being the most effective barrier on the apical surface glycocalyx. Here, we investigated the role of the mucoprotective drug rebamipide in the regulation of transmembrane mucin biosynthesis using stratified cultures of human corneal and conjunctival epithelial cells. We find that the addition of rebamipide to corneal, but not conjunctival, epithelial cells increased MUC16 protein biosynthesis. Rebamipide did not affect the levels of MUC1, 4 and 20 compared to control. In these experiments, rebamipide had no effect on the expression levels of Notch intracellular domains, suggesting that the rebamipide-induced increase in MUC16 biosynthesis in differentiated corneal cultures is not regulated by Notch signaling. Overall these findings indicate that rebamipide induces the differential upregulation of MUC16 in stratified cultures of human corneal epithelial cells, which may have implications to the proper restoration of barrier function in ocular surface disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Retinoblastoma Vitreous Seed Clouds (Class 3): A Comparison of Treatment with Ophthalmic Artery Chemosurgery with or without Intravitreous and Periocular Chemotherapy.

    PubMed

    Francis, Jasmine H; Iyer, Saipriya; Gobin, Y Pierre; Brodie, Scott E; Abramson, David H

    2017-10-01

    To compare the efficacy and toxicity of treating class 3 retinoblastoma vitreous seeds with ophthalmic artery chemosurgery (OAC) alone versus OAC with intravitreous chemotherapy. Retrospective cohort study. Forty eyes containing clouds (class 3 vitreous seeds) of 40 retinoblastoma patients (19 treated with OAC alone and 21 treated with OAC plus intravitreous and periocular chemotherapy). Ocular survival, disease-free survival and time to regression of seeds were estimated with Kaplan-Meier estimates. Ocular toxicity was evaluated by clinical findings and electroretinography: 30-Hz flicker responses were compared at baseline and last follow-up visit. Continuous variables were compared with Student t test, and categorical variables were compared with the Fisher exact test. Ocular survival, disease-free survival, and time to regression of seeds. There were no disease- or treatment-related deaths and no patient demonstrated externalization of tumor or metastatic disease. There was no significant difference in the age, laterality, disease, or disease status (treatment naïve vs. previously treated) between the 2 groups. The time to regression of seeds was significantly shorter for eyes treated with OAC plus intravitreous chemotherapy (5.7 months) compared with eyes treated with OAC alone (14.6 months; P < 0.001). The 18-month Kaplan-Meier estimates of disease-free survival were significantly worse for the OAC alone group: 67.1% (95% confidence interval, 40.9%-83.6%) versus 94.1% (95% confidence interval, 65%-99.1%) for the OAC plus intravitreous chemotherapy group (P = 0.05). The 36-month Kaplan-Meier estimates of ocular survival were 83.3% (95% confidence interval, 56.7%-94.3%) for the OAC alone group and 100% for the OAC plus intravitreous chemotherapy group (P = 0.16). The mean change in electroretinography responses was not significantly different between groups, decreasing by 11 μV for the OAC alone group and 22 μV for the OAC plus intravitreous chemotherapy group (P = 0.4). Treating vitreous seed clouds with OAC and intravitreous and periocular chemotherapy, compared with OAC alone, resulted in a shorter time to regression and was associated with fewer recurrences requiring additional treatment and fewer enucleations. The toxicity to the retina does not seem to be significantly worse in the OAC plus intravitreous chemotherapy group. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. 76 FR 76309 - Isoxaflutole; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-07

    ...). UFL = use of a LOAEL to extrapolate a NOAEL. UFS = use of a short-term study for long-term risk..., dermal, and inhalation routes of exposure and it is not a dermal sensitizer. In long-term studies via the... offspring exhibited ocular and liver toxicities as seen in long- term studies. In the acute and subchronic...

  14. Supportive Cryotherapy: A Review from Head to Toe

    PubMed Central

    Kadakia, Kunal C.; Rozell, Shaina A.; Butala, Anish A.; Loprinzi, Charles L.

    2013-01-01

    Context Conventional chemotherapy leads to multiple adverse mucocutaneous complications including oral mucositis, alopecia, ocular toxicity, and onycholysis. Limited pharmacologic interventions are available for preventing these clinical problems. Objectives This study aimed to critically review the role of cryotherapy (regional hypothermia) for alleviating these adverse symptoms. Methods A narrative review was performed, with an emphasis on randomized controlled trials. A comprehensive search using PubMed, Ovid, Embase, and MEDLINE® was completed. References of all cited articles also were reviewed. Data from the review were comprised of articles published between 1970 to May 2013. Results Available evidence suggests that regional hypothermia decreases the burden of chemotherapy-related oral mucositis, alopecia, ocular toxicity, and onycholysis. The major limitations of studies include the absence of blinded control groups and variable clinical endpoints. Conclusion Regional hypothermia decreases the burden of these four chemotherapy-induced complications and is well tolerated. More research is needed to determine what subgroups of cancer patients are most likely to respond to different types of regional hypothermia, the ideal duration of cooling needed, and to further improve the ease of use of the cooling devices. PMID:24210702

  15. Impact of magnetic field strength and receiver coil in ocular MRI: a phantom and patient study.

    PubMed

    Erb-Eigner, K; Warmuth, C; Taupitz, M; Willerding, G; Bertelmann, E; Asbach, P

    2013-09-01

    Generally, high-resolution MRI of the eye is performed with small loop surface coils. The purpose of this phantom and patient study was to investigate the influence of magnetic field strength and receiver coils on image quality in ocular MRI. The eyeball and the complex geometry of the facial bone were simulated by a skull phantom with swine eyes. MR images were acquired with two small loop surface coils with diameters of 4 cm and 7 cm and with a multi-channel head coil at 1.5 and 3 Tesla, respectively. Furthermore, MRI of the eye was performed prospectively in 20 patients at 1.5 Tesla (7 cm loop surface coil) and 3 Tesla (head coil). These images were analysed qualitatively and quantitatively and statistical significance was tested using the Wilcoxon-signed-rank test (a p-value of less than 0.05 was considered to indicate statistical significance). The analysis of the phantom images yielded the highest mean signal-to-noise ratio (SNR) at 3 Tesla with the use of the 4 cm loop surface coil. In the phantom experiment as well as in the patient studies the SNR was higher at 1.5 Tesla by applying the 7 cm surface coil than at 3 Tesla by applying the head coil. Concerning the delineation of anatomic structures no statistically significant differences were found. Our results show that the influence of small loop surface coils on image quality (expressed in SNR) in ocular MRI is higher than the influence of the magnetic field strength. The similar visibility of detailed anatomy leads to the conclusion that the image quality of ocular MRI at 3 Tesla remains acceptable by applying the head coil as a receiver coil. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Sutureless Fixation of Amniotic Membrane for Therapy of Ocular Surface Disorders

    PubMed Central

    Kotomin, Ilya; Valtink, Monika; Hofmann, Kai; Frenzel, Annika; Morawietz, Henning; Werner, Carsten; Funk, Richard H. W.; Engelmann, Katrin

    2015-01-01

    Amniotic membrane is applied to the diseased ocular surface to stimulate wound healing and tissue repair, because it releases supportive growth factors and cytokines. These effects fade within about a week after application, necessitating repeated application. Generally, amniotic membrane is fixed with sutures to the ocular surface, but surgical intervention at the inflamed or diseased site can be detrimental. Therefore, we have developed a system for the mounting of amniotic membrane between two rings for application to a diseased ocular surface without surgical intervention (sutureless amniotic membrane transplantation). With this system, AmnioClip, amniotic membrane can be applied like a large contact lens. First prototypes were tested in an experiment on oneself for wearing comfort. The final system was tested on 7 patients in a pilot study. A possible influence of the ring system on the biological effects of amniotic membrane was analyzed by histochemistry and by analyzing the expression of vascular endothelial growth factor-A (VEGF-A), hepatocyte growth factor (HGF), fibroblast growth factor 2 (FGF 2) and pigment epithelium-derived factor (PEDF) from amniotic membranes before and after therapeutic application. The final product, AmnioClip, showed good tolerance and did not impair the biological effects of amniotic membrane. VEGF-A and PEDF mRNA was expressed in amniotic membrane after storage and mounting before transplantation, but was undetectable after a 7-day application period. Consequently, transplantation of amniotic membranes with AmnioClip provides a sutureless and hence improved therapeutic strategy for corneal surface disorders. Trial Registration ClinicalTrials.gov NCT02168790 PMID:25955359

  17. Chronic dry eye in photorefractive keratectomy and laser in situ keratomileusis: Manifestations, incidence, and predictive factors.

    PubMed

    Bower, Kraig S; Sia, Rose K; Ryan, Denise S; Mines, Michael J; Dartt, Darlene A

    2015-12-01

    To evaluate dry-eye manifestations after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) and determine the incidence and predictive factors of chronic dry eye using a set of dry-eye criteria. Walter Reed Army Medical Center, Washington, DC, USA. Prospective, non-randomized clinical study. Dry-eye evaluation was performed before and after surgery. Main outcome measures included dry-eye manifestations, incidence, and predictive factors of chronic dry eye. This study comprised 143 active-duty U.S. Army personnel, ages 29.9 ± 5.2 years, with myopia or myopic astigmatism (manifest spherical equivalent -3.83 ± 1.96 diopters) having PRK or LASIK. Schirmer scores, corneal sensitivity, ocular surface staining, surface regularity index, and responses to dry-eye questionnaire significantly changed over time after PRK. After LASIK, significant changes were observed in tear breakup time, corneal sensitivity, ocular surface staining, and responses to questionnaire. Twelve months postoperatively, 5.0% of PRK and 0.8% of LASIK participants developed chronic dry eye. Regression analysis showed that pre-operatively lower Schirmer score will significantly influence development of chronic dry eye after PRK, whereas preoperatively, lower Schirmer score or higher ocular surface staining score will significantly influence the occurrence of chronic dry eye after LASIK. Chronic dry eye was uncommon after PRK and LASIK. Ocular surface and tear-film characteristics during pre-operative examination might help to predict chronic dry-eye development in PRK and LASIK. The authors have no financial interest in any product, drug, instrument, or equipment discussed in this manuscript. Copyright © 2015 ASCRS and ESCRS. All rights reserved.

  18. Influenza Virus Respiratory Infection and Transmission Following Ocular Inoculation in Ferrets

    PubMed Central

    Belser, Jessica A.; Gustin, Kortney M.; Maines, Taronna R.; Pantin-Jackwood, Mary J.; Katz, Jacqueline M.; Tumpey, Terrence M.

    2012-01-01

    While influenza viruses are a common respiratory pathogen, sporadic reports of conjunctivitis following human infection demonstrates the ability of this virus to cause disease outside of the respiratory tract. The ocular surface represents both a potential site of virus replication and a portal of entry for establishment of a respiratory infection. However, the properties which govern ocular tropism of influenza viruses, the mechanisms of virus spread from ocular to respiratory tissue, and the potential differences in respiratory disease initiated from different exposure routes are poorly understood. Here, we established a ferret model of ocular inoculation to explore the development of virus pathogenicity and transmissibility following influenza virus exposure by the ocular route. We found that multiple subtypes of human and avian influenza viruses mounted a productive virus infection in the upper respiratory tract of ferrets following ocular inoculation, and were additionally detected in ocular tissue during the acute phase of infection. H5N1 viruses maintained their ability for systemic spread and lethal infection following inoculation by the ocular route. Replication-independent deposition of virus inoculum from ocular to respiratory tissue was limited to the nares and upper trachea, unlike traditional intranasal inoculation which results in virus deposition in both upper and lower respiratory tract tissues. Despite high titers of replicating transmissible seasonal viruses in the upper respiratory tract of ferrets inoculated by the ocular route, virus transmissibility to naïve contacts by respiratory droplets was reduced following ocular inoculation. These data improve our understanding of the mechanisms of virus spread following ocular exposure and highlight differences in the establishment of respiratory disease and virus transmissibility following use of different inoculation volumes and routes. PMID:22396651

  19. Feasibility of quantitatively diagnosing cornea infection using Raman spectroscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bai, Yanru; Chen, Keren; Mishra, Arti; Beuerman, Roger; Liu, Quan

    2017-02-01

    Ocular infection is a serious eye disease that could lead to blindness without prompt and proper treatment. In pathology, ocular infection is caused by microorganisms such as bacteria, fungi or viruses. The essential prerequisite for the optimal treatment of ocular infection is to identify the microorganism causing infection early as each type of microorganism requires a different therapeutic approach. The clinical procedure for identifying the microorganism species causing ocular infection includes Gram staining (for bacteria)/microscopy (for fungi) and the culture of corneal surface scraping, or aqueous and vitreous smear samples taken from the surface of infected eyes. The culture procedure is labor intensive and expensive. Moreover, culturing is time consuming, which usually takes a few days or even weeks. Such a long delay in diagnosis could result in the exacerbation of patients' symptoms, the missing of the optimal time frame for initiating treatment and subsequently the rising cost for disease management. Raman spectroscopy has been shown highly effective for non-invasive identification of both fungi and bacteria qualitatively. In this study, we investigate the feasibility of identifying the microorganisms of ocular infection and quantifying the concentrations using Raman spectroscopy by measuring not only gram negative and gram positive bacteria but also infected cornea. By applying a modified orthogonal projection approach, the relative concentration of each bacteria species could be quantified. Our results indicate the great potential of Raman spectroscopy as an alternative tool for non-invasive diagnosis of ocular infection and could play a significantly role in future ophthalmology.

  20. Understanding the Presence and Roles of Ap4A (Diadenosine Tetraphosphate) in the Eye.

    PubMed

    Crooke, Almudena; Guzman-Aranguez, Ana; Carracedo, Gonzalo; de Lara, Maria J Perez; Pintor, Jesus

    Diadenosine tetraphosphate abbreviated Ap 4 A is a naturally occurring dinucleotide, which is present in most of the ocular fluids. Due to its intrinsic resistance to enzyme degradation compared to mononucleotides, this molecule can exhibit profound actions on ocular tissues, including the ocular surface, ciliary body, trabecular meshwork, and probably the retina. The actions of Ap 4 A are mostly carried out by P2Y 2 receptors, but the participation of P2X2 and P2Y 6 in processes such as the regulation of intraocular pressure (IOP), together with the P2Y 2 , is pivotal. Beyond the physiological role, this dinucleotide can present on the ocular surface keeping a right production of tear secretion or regulating IOP. It is important to note that exogenous application of Ap 4 A to cells or animal models can significantly modify pathophysiological conditions and thus is an attractive therapeutic molecule. The ocular location where Ap 4 A actions have not been fully elucidated is in the retina. Although some analogues show interesting actions on pathological situations such as retinal detachment, little is known about the real effect of this dinucleotide, this being one of the challenges that require pursuing in the near future.

  1. Comparing goblet cell densities in patients wearing disposable hydrogel contact lenses versus silicone hydrogel contact lenses in an extended-wear modality.

    PubMed

    Lievens, Christopher W; Connor, Charles G; Murphy, Heather

    2003-10-01

    The current study evaluates the response of the ocular surface to extended contact lens wear by comparing a new silicone hydrogel lens to an ACUVUE 2 lens. Twenty subjects with an average age of 28 years were randomly assigned to a fitting with ACUVUE 2 or PureVision lenses. Ocular surface assessment by impression cytology was performed at baseline and for the 6 months after initiation of lens wear. Although goblet cell density significantly increased with wear time, no statistically significant difference was observed between the contact lens groups. The average baseline goblet cell percentages were as follows: ACUVUE 2 group, 1.44; PureVision group, 1.11. The 6-month averages were as follows: ACUVUE 2 group, 3.16; PureVision group, 2.22. It appears that silicone hydrogel lenses may be slightly less irritating to the ocular surface than lenses not containing silicone. This could be a promising indicator for successful 30-day continuous wear.

  2. Prevalencia de síntomas de enfermedad de la superficie ocular en pacientes que acuden a consulta oftalmológica.

    PubMed

    Garza-León, Manuel; Hernández-Quintela, Everardo; Cámara-Castillo, Héctor G; Parra-Collin, Paola de la; Covarrubias-Espinosa, Paola; Sánchez-Huerta, Valeria; Castillo-Ruiz, Alejandro Del; Rodríguez-Sixtos, Fernando; Pacheco-Patrón, Jorge; Ochoa-Tabares, Juan Carlos; Soto-Ortiz, Karina; Hernández-Olguin, Karen

    2017-01-01

    To determine the prevalence of symptoms of ocular surface disease (OSDI) surface disease and its relationship with associated risk factors in patients of ophthalmic practices using OSDI questionnaire. A cross-sectional survey was conducted Between September and December 2014 to assess the prevalence and risk factors for OSDI. The OSDI average value was 40.46 ± 23.62 points, with 86.4% of patients (1967) having a OSDI score higher than 12 points. Women had OSDI symptoms more frequently than men (odds ratio: 1.17; 95% confidence interval: 1.08-1.28) and higher OSDI score (42.12 ± 24.03 vs. 38.01 ± 22.81 points). Patients without disease were younger than the patients with severe disease (45.30 ± 18.32 vs. 50.62 ± 18.86). Ophthalmological patients have a prevalence of 80.4% of OSDI. Female and older age was associated with ocular surface disease. Copyright: © 2017 SecretarÍa de Salud

  3. Altered Mucin and Glycoprotein Expression in Dry Eye Disease.

    PubMed

    Stephens, Denise N; McNamara, Nancy A

    2015-09-01

    Mucins are among the many important constituents of a healthy tear film. Mucins secreted and/or associated with conjunctival goblet cells, ocular mucosal epithelial cells, and the lacrimal gland must work together to create a stable tear film. Although many studies have explored the mechanism(s) whereby mucins maintain and protect the ocular surface, the effects of dry eye on the structure and function of ocular mucins are unclear. Here, we summarize current findings regarding ocular mucins and how they are altered in dry eye. We performed a literature review of studies exploring the expression of mucins produced and/or associated with tissues that comprise the lacrimal functional unit and how they are altered in dry eye. We also summarize new insights on the immune-mediated effects of aqueous tear deficiency on ocular surface mucins that we discovered using a mouse model of dry eye. Although consistent decreases in MUC5AC and altered expression of membrane-bound mucins have been noted in both Sjögren and non-Sjögren dry eye, many reports of altered mucins in dry eye are contradictory. Mechanistic studies, including our own, suggest that changes in the glycosylation of mucins rather than the proteins themselves may occur as the direct result of local inflammation induced by proinflammatory mediators, such as interleukin-1. Altered expression of ocular mucins in dry eye varies considerably from study to study, likely attributed to inherent difficulties in analyzing small-volume tear samples, as well as differences in tear collection methods and disease severity in dry eye cohorts. To better define the functional role of ocular mucin glycosylation in the pathogenesis of dry eye disease, we propose genomic and proteomic studies along with biological pathway analysis to reveal novel avenues for exploration.

  4. Efficacy and safety of two new formulations of artificial tears in subjects with dry eye disease: a 3-month, multicenter, active-controlled, randomized trial

    PubMed Central

    Simmons, Peter A; Liu, Haixia; Carlisle-Wilcox, Cindy; Vehige, Joseph G

    2015-01-01

    Purpose To evaluate and compare the efficacy and safety of two investigational artificial tear formulations (CHO-1 and CHO-2) containing carmellose sodium, hyaluronic acid at different concentrations, and osmoprotectants, with a standard carmellose sodium-containing formulation (Refresh Tears [RT]) in the treatment of dry eye disease. Subjects and methods In this 3-month, double-masked, multicenter study, subjects (n=305) were randomized 1:1:1 to receive CHO-1, CHO-2, or RT, used as needed but at least twice daily. The primary endpoint was change in ocular surface disease index (OSDI) score from baseline to day 90. Other key outcomes included symptoms evaluated on a visual analog scale, corneal and conjunctival staining, and adverse events. Results OSDI scores and dry eye symptoms showed a rapid and sustained reduction from baseline in each group. Both CHO-1 and CHO-2 met the primary efficacy endpoint of noninferiority to RT in day 90 OSDI score change from baseline. OSDI ocular symptoms subscale improved more with CHO-1 than CHO-2 (P=0.048). In subjects with clinically relevant baseline ocular surface staining (>14 total score of a maximum of 55), day 90 improvements were greater with CHO-1 and CHO-2 than RT (P≤0.044). Day 90 improvements in OSDI ocular symptoms subscale scores were also greater with CHO-1 than RT (P<0.007) in subjects with clinically relevant ocular staining. All treatments were well tolerated. Conclusion Both combination artificial tear formulations were efficacious and well tolerated in subjects with dry eye. CHO-1 demonstrated the best performance in improving ocular symptoms and reducing ocular staining in this heterogeneous study population. PMID:25931807

  5. Regulation of ocular surface inflammation by prostaglandin E receptor subtype EP3.

    PubMed

    Ueta, Mayumi

    2010-11-01

    We first investigated whether the prostaglandin (PG) E2-PGE receptor subtype EP3 axis regulates the development of murine experimental allergic conjunctivitis because it has been reported that this pathway negatively regulates allergic reactions in a murine allergic asthma model. We observed that EP3 is constitutively expressed in mice conjunctival epithelium. EP3 knockout mice demonstrated significantly increased eosinophil infiltration in conjunctiva after ragweed challenge compared with wild-type mice. Consistently, significantly higher expression of eotaxin-1 messenger RNA was observed in Ptger3-/- mice. Conversely, treatment of wild-type mice with an EP3-selective agonist significantly decreased eosinophil infiltration, which was blunted in Ptger3-/- mice. Expression of cyclooxygenase-2 and PGE synthases was upregulated and PGE2 content increased in the eyelids after ragweed challenge. These data suggest that PGE2 acts on EP3 in the conjunctival epithelium and downregulates the progression of experimental allergic conjunctivitis. We next examined and compared the expression of EP3 in human conjunctival epithelium in various ocular surface diseases. Human conjunctival epithelium expressed EP3-specific messenger RNA and EP3 protein. Although we could clearly find positive signals in the conjunctival epithelium from patients with noninflammatory ocular surface diseases such as conjunctivochalasis and pterygium, we could not find positive signals in that from those with inflammatory disorders such as Stevens-Johnson syndrome and ocular cicatricial pemphigoid. Likewise, expression of the PGE receptor subtype EP4 was clearly found in the conjunctival epithelium from patients with conjunctivochalasis and pterygium but not from patients with Stevens-Johnson syndrome and ocular cicatricial pemphigoid.

  6. Silk film biomaterials for ocular surface repair

    NASA Astrophysics Data System (ADS)

    Lawrence, Brian David

    Current biomaterial approaches for repairing the cornea's ocular surface upon injury are partially effective due to inherent material limitations. As a result there is a need to expand the biomaterial options available for use in the eye, which in turn will help to expand new clinical innovations and technology development. The studies illustrated here are a collection of work to further characterize silk film biomaterials for use on the ocular surface. Silk films were produced from regenerated fibroin protein solution derived from the Bombyx mori silkworm cocoon. Methods of silk film processing and production were developed to produce consistent biomaterials for in vitro and in vivo evaluation. A wide range of experiments was undertaken that spanned from in vitro silk film material characterization to in vivo evaluation. It was found that a variety of silk film properties could be controlled through a water-annealing process. Silk films were then generated that could be use in vitro to produce stratified corneal epithelial cell sheets comparable to tissue grown on the clinical standard substrate of amniotic membrane. This understanding was translated to produce a silk film design that enhanced corneal healing in vivo on a rabbit injury model. Further work produced silk films with varying surface topographies that were used as a simplified analog to the corneal basement membrane surface in vitro. These studies demonstrated that silk film surface topography is capable of directing corneal epithelial cell attachment, growth, and migration response. Most notably epithelial tissue development was controllably directed by the presence of the silk surface topography through increasing cell sheet migration efficiency at the individual cellular level. Taken together, the presented findings represent a comprehensive characterization of silk film biomaterials for use in ocular surface reconstruction, and indicate their utility as a potential material choice in the development of innovative procedures and technologies for corneal repair.

  7. Transcription, Translation, and Function of Lubricin, a Boundary Lubricant, at the Ocular Surface

    PubMed Central

    Schmidt, Tannin A.; Sullivan, David A.; Knop, Erich; Richards, Stephen M.; Knop, Nadja; Liu, Shaohui; Sahin, Afsun; Darabad, Raheleh Rahimi; Morrison, Sheila; Kam, Wendy R.; Sullivan, Benjamin D.

    2013-01-01

    Importance Lubricin may be an important barrier to the development of corneal and conjunctival epitheliopathies that may occur in dry eye disease and contact lens wear. Objective To test the hypotheses that lubricin (ie, proteoglycan 4 [PRG4]), a boundary lubricant, is produced by ocular surface epithelia and acts to protect the cornea and conjunctiva against significant shear forces generated during an eyelid blink and that lubricin deficiency increases shear stress on the ocular surface and promotes corneal damage. Design, Setting, and Participants Human, porcine, and mouse tissues and cells were processed for molecular biological, immunohistochemical, and tribological studies, and wild-type and PRG4 knockout mice were evaluated for corneal damage. Results Our findings demonstrate that lubricin is transcribed and translated by corneal and conjunctival epithelial cells. Lubricin messenger RNA is also present in lacrimal and meibomian glands, as well as in a number of other tissues. Absence of lubricin in PRG4 knockout mice is associated with a significant increase in corneal fluorescein staining. Our studies also show that lubricin functions as an effective friction-lowering boundary lubricant at the human cornea-eyelid interface. This effect is specific and cannot be duplicated by the use of hyaluronate or bovine serum albumin solutions. Conclusions and Relevance Our results show that lubricin is transcribed, translated, and expressed by ocular surface epithelia. Moreover, our findings demonstrate that lubricin presence significantly reduces friction between the cornea and conjunctiva and that lubricin deficiency may play a role in promoting corneal damage. PMID:23599181

  8. Transcription, translation, and function of lubricin, a boundary lubricant, at the ocular surface.

    PubMed

    Schmidt, Tannin A; Sullivan, David A; Knop, Erich; Richards, Stephen M; Knop, Nadja; Liu, Shaohui; Sahin, Afsun; Darabad, Raheleh Rahimi; Morrison, Sheila; Kam, Wendy R; Sullivan, Benjamin D

    2013-06-01

    Lubricin may be an important barrier to the development of corneal and conjunctival epitheliopathies that may occur in dry eye disease and contact lens wear. To test the hypotheses that lubricin (ie, proteoglycan 4 [PRG4 ]), a boundary lubricant, is produced by ocular surface epithelia and acts to protect the cornea and conjunctiva against significant shear forces generated during an eyelid blink and that lubricin deficiency increases shear stress on the ocular surface and promotes corneal damage. Human, porcine, and mouse tissues and cells were processed for molecular biological, immunohistochemical, and tribological studies, and wild-type and PRG4 knockout mice were evaluated for corneal damage. Our findings demonstrate that lubricin is transcribed and translated by corneal and conjunctival epithelial cells. Lubricin messenger RNA is also present in lacrimal and meibomian glands, as well as in a number of other tissues. Absence of lubricin in PRG4 knockout mice is associated with a significant increase in corneal fluorescein staining. Our studies also show that lubricin functions as an effective friction-lowering boundary lubricant at the human cornea-eyelid interface. This effect is specific and cannot be duplicated by the use of hyaluronate or bovine serum albumin solutions. Our results show that lubricin is transcribed, translated, and expressed by ocular surface epithelia. Moreover, our findings demonstrate that lubricin presence significantly reduces friction between the cornea and conjunctiva and that lubricin deficiency may play a role in promoting corneal damage.

  9. Ocular surface changes following oral anticholinergic use for overactive bladder.

    PubMed

    Sekeroglu, Mehmet Ali; Hekimoglu, Emre; Tasci, Yasemin; Dolen, Ismail; Arslan, Umut

    2016-09-01

    To investigate the effect of oral solifenacin succinate on Schirmer I test results, tear break-up time (TBUT) and Ocular Surface Disease Index (OSDI) scores in overactive bladder (OAB) patients and to compare these results with those of healthy control subjects. The female OAB patients who were prescribed oral solifenacin succinate 5 mg/day (Group I, N = 80) and age-matched healthy female subjects (Group II, N = 40) were recruited for the study and underwent ophthalmological examination prior to oral treatment and after 4 weeks. They completed the OSDI questionnaire and underwent ocular surface tests including Schirmer I test and TBUT. The statistical analysis of the Schirmer I test and TBUT revealed no significant difference between the baseline and 4th week values in both groups (Group I, p = 0.506 and p = 0.070 consecutively) (Group II, p = 0.810 and p = 0.823 consecutively). OSDI scores were found to be significantly increased in group I (21.8 ± 4.2 vs 23.1 ± 4.6, p = 0.020) and remained unchanged in group II (20.5 ± 7.0 vs 20.7 ± 7.0, p = 0.805). Short-term solifenacin succinate treatment has no effect on the Schirmer I test results and TBUT, but ocular surface symptoms appeared to be exacerbated in respect with increased OSDI scores. However, the clinical significance needs to be further evaluated with larger studies.

  10. Ocular Surface Disease in Glaucoma: Effect of Polypharmacy and Preservatives.

    PubMed

    Ramli, Norlina; Supramaniam, Gowri; Samsudin, Amir; Juana, Azida; Zahari, Mimiwati; Choo, May May

    2015-09-01

    To evaluate the prevalence of ocular surface disease (OSD) in glaucoma and nonglaucoma subjects using different clinical tests and to determine the effect of number of antiglaucoma medications and preservatives on OSD. This is a cross-sectional, case-comparison study at the Eye Clinic of the University of Malaya Medical Centre, Malaysia, between June 2012 and January 2013. Glaucoma subjects (n = 105) using topical antiglaucoma medications were compared with control subjects (n = 102) who were not on any topical medications. The presence of OSD was assessed using the tear film breakup time (TBUT) test, corneal staining, Schirmer test, and Ocular Surface Disease Index (OSDI) questionnaire grading. The prevalence of OSD varied from 37 to 91% in the glaucoma group, depending on the type of clinical test. More subjects in the glaucoma group had corneal staining (63% vs. 36%, p = 0.004), abnormal Schirmer tests (39% vs. 25%, p = 0.049), and moderate OSDI symptoms (17% vs. 7%, p = 0.028). The percentage with abnormal TBUT increased with higher numbers of topical medications and was high with both benzalkonium chloride-containing and preservative-free eye drops (90% and 94%, respectively, both p < 0.001). Benzalkonium chloride was associated with a nearly three times higher odds ratio of showing abnormal OSDI. Ocular surface disease is common in those using topical antiglaucoma medications. Abnormal TBUT is associated with increasing number of eye drops and benzalkonium chloride-containing eye drops, although this also occurs with the use of preservative-free eye drops.

  11. Ocular surface infections in northeastern state of malaysia: a 10-year review of bacterial isolates and antimicrobial susceptibility.

    PubMed

    Rahman, Zaidah A; Harun, Azian; Hasan, Habsah; Mohamed, Zeehaida; Noor, Siti S Md; Deris, Zakuan Z; Ismail, Nabilah; Hassan, Asma S; Ahmad, Fadzhilah; Yaakub, Azhany

    2013-09-01

    Ocular surface infections that include infections of conjunctiva, adnexa, and cornea have the potential risk of causing blindness within a given population. Empirical antibiotic therapy is usually initiated based on epidemiological data of common causative agents. Thus, the aims of this study were to determine the bacterial agents and their susceptibility patterns of isolates from ocular surface specimens in our hospital. This is a retrospective analysis and records of bacterial isolates from ocular surface specimens in Hospital Universiti Sains Malaysia from January 2001 to December 2010 were examined. Specimens were processed according to standard laboratory procedures. Antimicrobial susceptibility testing was conducted based on Clinical and Laboratory Standards Institute recommendations. Only single, nonrepetitive isolates were included in the analysis. A total of 1,267 isolates were obtained during the study period, which comprised Staphylococcus aureus (n = 299, 23.6%), Pseudomonas aeruginosa (n = 194, 15.3%), Streptococcus pneumoniae (n = 108, 8.5%), Haemophilus influenzae (n = 100, 7.9%), Haemophilus parainfluenzae (n = 84, 6.6%), and Enterobacter spp. (n = 81, 6.4%). Fungi contributed to 4.4% of the total isolates. The antimicrobial susceptibility testing demonstrated that gram-positive bacteria were generally resistant to gentamicin (19%-57%), whereas gram-negative bacteria were resistant to chloramphenicol (27%-58%). Based on the above results, knowledge of the initial Gram stain findings is imperative before the commencement of empirical antibiotic therapy. Therefore, a simple Gram staining for all eye specimens is highly recommended.

  12. Ocular surface and tear functions after topical cyclosporine treatment in dry eye patients with chronic graft-versus-host disease.

    PubMed

    Wang, Y; Ogawa, Y; Dogru, M; Kawai, M; Tatematsu, Y; Uchino, M; Okada, N; Igarashi, A; Kujira, A; Fujishima, H; Okamoto, S; Shimazaki, J; Tsubota, K

    2008-02-01

    We investigated the effect of 0.05% topical cyclosporine (Cys) on the ocular surface and tear functions in dry eye patients with chronic GVHD (cGVHD) in a prospective comparative study. Thirty eyes of 15 patients refractory to baseline treatment were recruited and the patients assigned for topical Cys treatment group (14 eyes of 7 patients) and control group (12 eyes of 6 patients) respectively. Two patients dropped out because of intolerable irritation while using topical Cys eye drops. Visual analog scale symptom scores, corneal sensitivity, Schirmer I test value, tear film break-up time (TBUT), tear evaporation rate and ocular surface vital staining scores were recorded at baseline and at the end of the following one month. Conjunctival impression and brush cytology were performed before and after the treatment. After topical Cys treatment, significant improvements were found in symptom scores, corneal sensitivity, tear evaporation rate, TBUT, vital staining scores, goblet cells density, conjunctival squamous metaplasia grade, inflammatory cell numbers and the MUC5AC expression. Our study suggests that 0.05% topical Cys may be an effective treatment for dry eye patients with cGVHD. The improvements in the ocular surface and tear functions resulted presumably from the decreased inflammation, increased goblet cell density and MUC5AC mRNA expression. Bone Marrow Transplantation (2008) 41, 293-302; doi:10.1038/sj.bmt.1705900; published online 5 November 2007.

  13. From toxicological problem to therapeutic use: the discovery of the mode of action of 2-(2-nitro-4-trifluoromethylbenzoyl)-1,3-cyclohexanedione (NTBC), its toxicology and development as a drug.

    PubMed

    Lock, E A; Ellis, M K; Gaskin, P; Robinson, M; Auton, T R; Provan, W M; Smith, L L; Prisbylla, M P; Mutter, L C; Lee, D L

    1998-08-01

    NTBC is a triketone with herbicidal activity that has been shown to have a novel mode of action by inhibiting the enzyme 4-hydroxyphenylpyruvate dioxygenase in plants. Early studies on the toxicity of this compound found that rats treated with NTBC developed corneal lesions. Investigations aimed at understanding the mechanistic basis for the ocular toxicity discovered that the rats developed tyrosinaemia and excreted large amounts of 4-hydroxyphenylpyruvate and 4-hydroxyphenyllactate, owing to inhibition of the hepatic enzyme 4-hydroxyphenylpyruvate dioxygenase. The corneal lesions resemble those seen when rats are fed a diet supplemented with tyrosine, leading us to conclude that the ocular toxicity seen with NTBC is a consequence of a marked and sustained tyrosinaemia. Studies in collaboration with Professor Sven Lindstedt showed that NTBC was a potent inhibitor of purified human liver 4-hydroxyphenylpyruvate dioxygenase. This interaction lead to the concept of using NTBC to treat patients with tyrosinaemia type 1, to block or reduce the formation of toxic metabolites such as succinylacetoacetate in the liver. Zeneca Agrochemicals and Zeneca Pharmaceuticals made NTBC available for clinical use and, with the approval of the Swedish Medical Products Agency, a seriously ill child with an acute form of tyrosinaemia type 1 was successfully treated in February 1991. Subsequently, other children with this inborn error of metabolism in Sweden and other countries have been treated with NTBC. The drug is now available to those in need via Swedish Orphan AB.

  14. Meibomian gland dysfunction and ocular discomfort in video display terminal workers.

    PubMed

    Fenga, C; Aragona, P; Cacciola, A; Spinella, R; Di Nola, C; Ferreri, F; Rania, L

    2008-01-01

    Meibomian gland dysfunction (MGD) is one of the most common ocular disorders encountered in clinical practice. The clinical manifestations of MGD are related to the changes in the tear film and ocular surface with symptoms of ocular discomfort. In recent years, many surveys have evaluated symptoms associated with the use of Video Display Terminals (VDT), and VDT use is recognized as a risk factor for eye discomfort. The aim of the present study was to determine if the presence of MGD contributes to the signs and symptoms of ocular discomfort during the use of VDT. In course of a routine health surveillance programme, a group of 70 subjects fulfilled the inclusion criteria and responded to a questionnaire about symptoms of ocular discomfort. The following ocular tests were performed: tear break-up time, fluorescein corneal stain, and basal tear secretion test. A total of 52 subjects out of 70 (74.3%) had MGD. A statistically significant correlation between the symptoms of ocular discomfort and hours spent on VDT work was observed in the total population (r=0.358; P=0.002; 95% CI 0.13-0.54) and in the group of subjects with MGD (r=0.365; P=0.009; 95% CI 0.103-0.58). Such correlation was not shown in subjects without MGD. The high prevalence of MGD among the subjects with symptoms of ocular discomfort suggests that this diagnosis should be considered when occupational health practitioners encounter ocular complaints among VDT operators. It appears that MGD can contribute to the development of ocular discomfort in VDT operators.

  15. In vitro testing of thiolated poly(aspartic acid) from ophthalmic formulation aspects.

    PubMed

    Budai-Szű Cs, Mária; Horvát, Gabriella; Gyarmati, Benjámin; Szilágyi, Barnabás Áron; Szilágyi, András; Csihi, Tímea; Berkó, Szilvia; Szabó-Révész, Piroska; Mori, Michela; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Csányi, Erzsébet

    2016-08-01

    Ocular drug delivery formulations must meet anatomical, biopharmaceutical, patient-driven and regulatory requirements. Mucoadhesive polymers can serve as a better alternative to currently available ophthalmic formulations by providing improved bioavailability. If all requirements are addressed, a polymeric formulation resembling the tear film of the eye might be the best solution. The optimum formulation must not have high osmotic activity, should provide appropriate surface tension, pH and refractive index, must be non-toxic and should be transparent and mucoadhesive. We would like to highlight the importance of in vitro polymer testing from a pharmaceutical aspect. We, therefore, carried out physical-chemical investigations to verify the suitability of certain systems for ophthalmic formulations. In this work, in situ gelling, mucoadhesive thiolated poly(aspartic acid)s were tested from ophthalmic formulation aspects. The results of preformulation measurements indicate that these polymers can be used as potential carriers in ophthalmic drug delivery.

  16. [Novel current and future therapy options for treatment of dry eye disease].

    PubMed

    Messmer, E M

    2018-02-01

    Dry eye disease was redefined by the dry eye workshop (DEWS II) in May 2017. According to the new definition "dry eye is a multifactorial disease of the ocular surface characterized by a loss of homeostasis of the tear film and accompanied by ocular symptoms". The current definition encompasses etiological factors, such as instability and hyperosmolarity of the tear film, ocular surface inflammation and damage as well as a new aspect compared to the former definition, neurosensory abnormalities. Recent and future therapeutic options for dry eye focus on treatment of the aforementioned pathogenetic events. New tear substitutes, medications and devices to stimulate tear production, innovative anti-inflammatory treatment, medications to influence corneal innervation and new methods for treatment of Meibomian gland dysfunction are already available or will be available in the near future.

  17. Ocular manifestations of rheumatoid arthritis and their correlation with anti-cyclic citrullinated peptide antibodies.

    PubMed

    Vignesh, Ammapati Paul Pandian; Srinivasan, Renuka

    2015-01-01

    To study the ocular manifestations of rheumatoid arthritis and to correlate the role of anti-cyclic citrullinated peptide antibody (anti-CCP antibody) with the ocular manifestations. Three-hundred and ninety-two eyes of the 196 rheumatoid arthritis patients who attended the ophthalmology outpatient department underwent a detailed ocular examination using slit lamp biomicroscopy and ophthalmoscopy. The tear function of all the patients was assessed using Schirmer's test, tear film break-up time and ocular surface staining. The anti-CCP antibody titers for all the rheumatoid arthritis patients were estimated using enzyme-linked immunosorbent assay tests. Seventy-seven patients (135 eyes, 39%) out of the 196 patients studied had ocular manifestations typical of rheumatoid arthritis. Dry eye was the most common manifestation (28%, 54 patients). Of the patients, 78% was females (60 patients). The mean duration of rheumatoid arthritis in patients with ocular manifestations was 5.4±2.7 years and without ocular manifestations was 2.1±1.6years. Three percent of the patients had episcleritis (six patients). Scleritis was present in 2% of the patients (four patients). Peripheral ulcerative keratitis and sclerosing keratitis was present in 1% of the population each (two patients each). Eighty-five percent (66 patients) had bilateral manifestations 15% (eleven patients) had unilateral manifestations. There was a strong association between the presence of anti-CCP antibodies and ocular manifestations of rheumatoid arthritis which was shown by the statistically significant P-value of <0.0001. Ocular manifestations are a significant part of the extra-articular manifestation of rheumatoid arthritis. Dry eye was the most common ocular manifestation. There was a statistically significant association between the presence of anti-CCP antibodies specific to rheumatoid arthritis and the ocular manifestations.

  18. Opiate and N-methyl-D-aspartate receptors in form-deprivation myopia.

    PubMed

    Fischer, A J; Seltner, R L; Stell, W K

    1998-01-01

    Pharmacological studies have implicated retinal opiate pathways in the visual regulation of ocular growth. However, the effects of opiate receptor subtype-specific compounds on form-deprivation myopia (FDM) are inconsistent (Seltner et al., 1997), and may be mediated by non-opiate receptors. The purpose of this study was to test whether opiate receptor-inactive (D-) enantiomers elicit the same FDM-suppressing effect as their opiate receptor-active (L-) counterparts. Since some opiates are thought to act at NMDA receptors, we also tested whether NMDA receptor agonists and antagonists influence ocular growth or FDM. We found that both L- and D- enantiomers of morphine-like compounds (dextrorphanol and levorphanol, and D- and L-naloxone) were equally effective in blocking FDM. The NMDA receptor antagonists dextromethorphan, MK801, and AP5 also suppressed FDM. A single toxic dose of NMDA, that destroys many subtypes of amacrine cells (including those that synthesize the opioid peptide enkephalin), induced myopia and ocular enlargement in ungoggled eyes, and eliminated the ability of form-deprivation to enhance ocular growth. The NR-1 subunit of the NMDA receptor was localized to a narrowly stratified, intense stratum at approximately 50% depth in the inner plexiform layer, diffusely throughout the proximal inner plexiform layer, and to many somata in the amacrine and ganglion cell layers. These observations suggest that most effects of opiate receptor ligands on FDM in the chick are mediated by non-opiate receptors, which are likely to include NMDA receptors. NMDA as an excitotoxin transiently enhances ocular growth, but thereafter disables retinal mechanisms that promote emmetropization and FDM. These observations are consistent with a prominent role for pathways utilizing NMDA receptors in FDM and ocular growth-control.

  19. Optic neuritis with residual tunnel vision in perchloroethylene toxicity.

    PubMed

    Onofrj, M; Thomas, A; Paci, C; Rotilio, D

    1998-01-01

    In a 57-year-old female owner of a dry-cleaning shop, we describe the association of severe bilateral optic neuritis with unexpectedly high concentrations of perchloroethylene/metabolites in the blood and of chloroform in urine. Visual disturbances consisted of complete blindness for 9 days in the left eye, for 11 days in the right eye, with bright phosphenes and pain on eye rotation. Only central (2-3 degrees radius) vision recovered in the following months. Although environmental concentrations of perchloroethylene were within normal limits, we measured five-fold increases in vapors emitted when ironing freshly dry-cleaned fabrics, and suggest that inhalation of perchloroethylene vapors was the cause of this case of ocular nerve toxicity, recapitulating a previous report of major perchloroethylene toxicity.

  20. Prevalence of ocular symptoms and signs with preserved and preservative free glaucoma medication

    PubMed Central

    Pisella, P J; Pouliquen, P; Baudouin, C

    2002-01-01

    Aim: To determine the incidence of ocular toxicity of preservatives with glaucoma medications. Methods: A prospective epidemiological survey was carried out in 1999 by 249 ophthalmologists on 4107 patients. Ocular symptoms, conjunctiva, cornea, and eyelids were assessed. A χ2 test was used for differences between preserved eye drops (P) and preservative free eye drops (PF). Results: 84% patients used P, 13% received PF, and 3% a combination of P and PF eye drops. All symptoms were more prevalent with P than with PF drops (p<0.001): discomfort upon instillation (43% versus 17%), and symptoms between instillations such as burning-stinging (40% versus 22%), foreign body sensation (31% versus 14%), dry eye sensation (23% versus 14%), tearing (21% versus 14%), and eyelid itching (18% versus 10%). An increased incidence (>2 times) of ocular signs was seen with P eye drops. The prevalence of signs and symptoms was dose dependent, increasing with the number of P drops. A reduction in the symptoms and signs was observed when patients changed from P to PF eye drops (p<0.001). Conclusions: Symptoms and signs are less prevalent when PF drops are used. Moreover, most of the adverse reactions induced by P glaucoma medication are reversible after removing preservatives. PMID:11914211

  1. Evaluation of seven in vitro alternatives for ocular safety testing.

    PubMed

    Bruner, L H; Kain, D J; Roberts, D A; Parker, R D

    1991-07-01

    Seven in vitro assays were evaluated to determine if any were useful as screening procedures in ocular safety assessment. Seventeen test materials (chemicals, household cleaners, hand soaps, dishwashing liquids, shampoos, and liquid laundry detergents) were tested in each assay. In vivo ocular irritation scores for the materials were obtained from existing rabbit low volume eye test (LVET) data. The seven assays evaluated included the silicon microphysiometer (SM), luminescent bacteria toxicity test (LBT), neutral red assay (NR), total protein assay (TP), Tetrahymena thermophila motility assay (TTMA), bovine eye/chorioallantoic membrane assay (BE/CAM), and the EYTEX system (ETS). For the seventeen materials used in this study there was a significant correlation between the in vivo irritant potential and in vitro data for all the tests except the EYTEX System (SM, r = -0.87; LBT, r = -0.91; NR, r = -0.85; TTMA, r = 0.78; TP, r = -0.86; ETS, r = 0.29). The irritation classifications provided by the BE/CAM also did not correspond with the actual in vivo irritancy potential of the test materials. The result of this study suggested it may be possible to classify materials into broad irritancy categories with some of the assays. This would allow their use as screens prior to limited in vivo confirmation in the ocular safety assessment process.

  2. The influence of selected excipients on the rheological behaviour of chitosan based ocular pharmaceutical systems

    NASA Astrophysics Data System (ADS)

    Budai, L.; Szabadi, E.; Hajdú, M.; Budai, M.; Klebovich, I.; Antal, I.

    2015-04-01

    Aims: Chitosan, a modified natural carbohydrate polymer, has received great attention in diverse scientific fields including pharmaceutical and biomedical research areas. Besides its low toxicity, mucoadhesiveness and biodegradability its special favourable rheological feature makes it a unique gelling agent for the design of ocular systems. Chitosan based (2.0 w/v %) ocular systems containing selected excipients were formulated in order to investigate the rheological influence of applied auxiliary materials. Rotational and oscillatory rheological properties of propylene glycol (1.0-20.0 w/v %), glycerin (1.0-5.0 w/v %) and castor oil (1.0-5.0 w/v %) containing chitosan gels were evaluated. The rheological behaviour of formulated ocular gels were compared before and after steam sterilization. Methods: Rotational and oscillatory rheological measurements were carried out with Kinexus Pro Rheometer. Comparison of flow curves and oscillatory frequency sweep measurements in the linear viscoelastic region made possible the evaluation of rheological effect of selected excipients. Results: In the applied concentration range the effect of propylene glycol among the selected excipients presents the most significant impact on rheology of chitosan formulations. Steam sterilization results in reduced viscosity in most of chitosan gels. However, the presence of polyols appears to prevent the degradation of chitosan after steam sterilization.

  3. An impression cytology based study of ocular surface in an urban population.

    PubMed

    Mukhopadhyay, Somnath; Dutta, Jayanta; Mitra, Jayati; Prakash, Ratnesh; Datta, Himadri

    2013-04-01

    To assess the health of ocular surface in a defined urban population, conjunctival goblet cell density and degree of surface squamous metaplasia were utilized as study tools. Two thousand names of those aged between 20 and 79 years from the 2006 electoral register in ward number 63 of Kolkata Corporation area were initially selected. Normal healthy human volunteers without any history of ocular surface disorder were recruited and divided into five age-groups. Impression cytology samples were obtained from interpalpebral part of bulbar conjunctiva from all the participants fixated and stained by a single observer. A stratified, clustered, disproportionate, random sampling method was used. The software used in the statistical analysis was EPI Info. The tests applied were t test and ANOVA. A variation in the number of goblet cells according to gender (women having less cells) and age (20-30 years group having the highest number of cells) was found. Those working outdoors were found to have fewer goblet cells compared to those who stay indoors. The majority of the people had grade 1 cytological appearance in both males and females. There was no statistically significant difference in Nelson's grading with age. People using coal and kerosene to cook were found to have a smaller goblet cell density than those who cooked on LPG or those who did not cook at all. Besides age and sex, environmental factors like the method of cooking and occupational variables (like outdoor activity, prolonged period of computer use, etc.) modify the health of the ocular surface. The results of this study will help put these findings into perspective as public health problems.

  4. Case control study of dry eye and related ocular surface abnormalities in Ibadan, Nigeria.

    PubMed

    Bekibele, C O; Baiyeroju, A M; Ajaiyeoba, A; Akang, E E U; Ajayi, B G K

    2010-02-01

    Tear instability is associated with symptoms of ocular discomfort and irritation. Many patients with dry eyes remain untreated due to improper diagnoses. To identify symptoms and surface abnormalities associated with dry eyes. One hundred and fifty-six eyes of 78 subjects attending the Eye Clinic of the University College Hospital Ibadan were screened for dry eyes/tear instability using rose Bengal stain (graded 0-9), tear break-up time (TBUT), Schirmer's 1 tests, tear meniscus height and a standardised symptoms questionnaire. Grades 4-9 rose Bengal staining were considered as positive dry eye and were compared with grades 0-3 staining eyes as negative controls. Mean tear meniscus height, Schirmer's test and TBUT were lower among cases than their corresponding control eyes. The difference between the mean Schirmer's test values of cases and their controls were statistically significant (P = 0.00 for right eyes and P = 0.002 for left eyes). Rose Bengal grades were inversely correlated with the mean Schirmer's values (Pearson correlation -0.429, P = 0.05 for right eyes and -0.335, P = 0.03 for left eyes) and TBUT (Pearson correlation -0.316, P = 0.05 for right eyes and -0.212, P = 0.06 for left eyes). About 95.8% of the cases were symptomatic, as opposed to 70.4% of the controls (P = 0.01, Fisher's exact test) and 95.8% of dry right eyes compared to 61.1% of their controls had ocular surface abnormalities (P = 0.001), while 89.5% of dry left eyes compared to 62.7% of controls had surface abnormalities (P = 0.07). A close relationship exists between ocular irritation symptoms, surface abnormalities and functional evidence of tear instability. Such patients should be treated empirically or screened for dry eyes.

  5. The Effects of Increasing Ocular Surface Stimulation on Blinking and Sensation

    PubMed Central

    Wu, Ziwei; Begley, Carolyn G.; Situ, Ping; Simpson, Trefford

    2014-01-01

    Purpose. The purpose of this study was to determine how increasing ocular surface stimulation affected blinking and sensation, while controlling task concentration. Methods. Ten healthy subjects concentrated on a task while a custom pneumatic device generated air flow toward the central cornea. Six flow rates (FRs) were randomly presented three times each and subjects used visual analog scales to record their sensory responses. The interblink interval (IBI) and the FR were recorded simultaneously and the IBI, sensory response, and corresponding FR were determined for each trial. The FR associated with a statistically significant decrease in IBI, the blink increase threshold (BIT), was calculated for each subject. Results. Both the mean and SD of IBI were decreased with increasing stimulation, from 5.69 ± 3.96 seconds at baseline to 1.02 ± 0.37 seconds at maximum stimulation. The average BIT was 129 ± 20 mL/min flow rate with an IBI of 2.33 ± 1.10 seconds (permutation test, P < 0.001). After log transformation, there was a significant linear function between increasing FR and decreasing IBI within each subject (Pearson's r ≤ −0.859, P < 0.05). The IBI was highly correlated with wateriness, discomfort, and cooling ratings (Pearson's r ≤ −0.606, P < 0.001). Conclusions. There was a dose-response–like relationship between increased surface stimulation and blinking in healthy subjects, presumably for protection of the ocular surface. The blink response was highly correlated with ocular surface sensation, which is not surprising given their common origins. The BIT, a novel metric, may provide an additional end point for studies on dry eye or other conditions. PMID:24557346

  6. Effects of poly(2-hydroxyethyl methacrylate) and poly(vinyl-pyrrolidone) hydrogel implants on myopic and normal chick sclera

    PubMed Central

    Su, James; Iomdina, Elena; Tarutta, Elena; Ward, Brian; Song, Jie; Wildsoet, Christine F.

    2008-01-01

    There has been generally little attention paid to the utilization of biomaterials as an anti-myopia treatment. The purpose of this study was to investigate whether polymeric hydrogels, either implanted or injected adjacent to the outer scleral surface, slow ocular elongation. White Leghorn (gallus gallus domesticus) chicks were used at 2 weeks of age. Chicks had either (1) strip of poly(2-hydroxyethyl methacrylate) (pHEMA) implanted monocularly against the outer sclera at the posterior pole, or (2) an in situ polymerizing gel [main ingredient: poly(vinyl-pyrrolidone) (PVP)] injected monocularly at the same location. Some of the eyes injected with the polymer were fitted with a diffuser or a −10D lens. In each experiment, ocular lengths were measured at regular intervals by high frequency A-scan ultrasonography, and chicks were sacrificed for histology at staged intervals. No in vivo signs of either orbital or ocular inflammation were observed. The pHEMA implant significantly increased scleral thickness by the third week, and the implant became encapsulated with fibrous tissue. The PVP-injected eyes left otherwise untreated, showed a significant increase in scleral thickness, due to increased chondrocyte proliferation and extracellular matrix deposition. However, there was no effect of the PVP injection on ocular elongation. In eyes wearing optical devices, there was no effect on either scleral thickness or ocular elongation. These results represent “proof of principle” that scleral growth can be manipulated without adverse inflammatory responses. However, since neither approach slowed ocular elongation, additional factors must influence scleral surface area expansion in the avian eye. PMID:19109950

  7. A Novel Combination Therapy for Patients With Dry Eye Disease: A Pilot Study.

    PubMed

    Smith, Will; McMahon, David; Nymark, Maria

    2018-05-01

    Context • Approximately 25% of the US population suffers from dry eyes or some abnormality of the exposed ocular surface. Investigation of effective modalities for their management is needed. Objective • The study intended to examine the efficacy of a proprietary, daily, Dry Eye Protocol consisting of daily use of a moist, heated, ocular compress and intake of an omega-3 dietary supplement in treatment of ocular surface disease. Design • The research team designed a 4-wk, clinically based, open-label, multicenter cohort study. Setting • The study took place at 6 private eye care practices throughout the United States: Beverly Hills, CA, USA; San Diego, CA, USA; Sunnyvale, CA, USA; Park City, UT, USA; Tarpon Spring, FL, USA; and Kennewick, WA, USA. Participants • Participants were adults between 18 and 75 y of age who had established ocular surface disease based on clinical findings and the results of testing using the ocular surface disease index (OSDI). Intervention • For period of 30 d, participants used a combined daily protocol that included (1) application of a moist, heated, eye compress and (2) a nutritional therapy via an omega-3 supplement in an oral triglyceride form. Outcome Measures • Measures included the OSDI and a test of tear break-up time (TBUT). Results • Of the original 35 participants, 33 completed the 4-wk protocol. The participants using the proprietary Dry Eye Protocol showed significant improvements from baseline, demonstrated by a 49% decrease in OSDI scores (P = .0015); and 46% of participants reported becoming asymptomatic of dry eye symptoms. A significant improvement was also observed in TBUT, increasing from 3.0 to 5.4 s. Conclusions • Daily use of the proprietary Dry Eye Protocol that included a high dosage of triglyceride omega-3 and use of a moist, heated, compress daily showed significant improvement for participants in OSDI and TBUT and should be considered to be a first-line therapy for patients with dry eye disease.

  8. Changing therapeutic paradigms in CMV retinitis in AIDS.

    PubMed

    Piper, H; Ciulla, T A; Danis, R P; Pratt, L M

    2000-12-01

    Cytomegalovirus (CMV) retinitis is a common ocular complication of immunosuppression. The management of CMV retinitis has been continuously evolving over the last decade. The mainstay of therapy remains ganciclovir and foscarnet. However, increasing resistance and ongoing toxicities to these agents remain a challenge. Additional frequently utilised agents include cidofovir and fomivirsen. The advent of highly active antiretroviral therapy (HAART) has allowed the restoration of immunocompetency to many patients previously challenged by CMV infection. In some circumstances, HAART has even eliminated the need for ongoing antiviral therapy. This paper reviews the current treatment modalities, including their toxicities and dosing recommendations.

  9. Treatment of acute posterior uveitis in a porcine model by injection of triamcinolone acetonide into the suprachoroidal space using microneedles.

    PubMed

    Gilger, Brian C; Abarca, Eva M; Salmon, Jacklyn H; Patel, Samirkumar

    2013-04-03

    To evaluate the effect of triamcinolone acetonide (TA) administered into the suprachoroidal space (SCS) using a microneedle and compare it with intravitreal (IVT) TA injections in a porcine model of acute posterior segment inflammation. An IVT injection of balanced salt solution (BSS) or lipopolysaccharide (LPS) was followed 24 hours later with an injection of 0.2 mg or 2.0 mg of TA into the SCS or IVT. The SCS was accessed using microneedles in a minimally invasive procedure. Ocular inflammatory scores and IOP measurements were collected daily, whereas electroretinography, optical coherence tomography, and wide-field ocular fundus photography was performed on -1, 0, and 3 days after treatment. Aqueous and vitreous humor cell counts and protein levels and histopathology were also compared. Delivery of TA to the SCS using microneedles was simple, effective, and not associated with adverse effects or toxicity. SCS injection of low (0.2 mg) and high doses (2.0 mg) of TA was as effective in reducing acute inflammation in the ocular posterior segment as high-dose IVT injection. Low-dose SCS TA was also effective in reducing inflammation; however, low-dose IVT TA was not. Results from this study suggest that 0.2 mg and 2.0 mg of SCS TA was as effective in reducing inflammation as 2.0 mg IVT TA injection in a model of acute posterior segment inflammation. There were no adverse effects, increased IOP, or evidence of procedural or drug toxicity following injection of TA into the SCS in porcine eyes.

  10. Antimicrobial role of human meibomian lipids at the ocular surface.

    PubMed

    Mudgil, Poonam

    2014-10-14

    Human meibomian lipids form the outermost lipid layer of the tear film and serve many important functions to maintain its integrity. Although not investigated earlier, these lipids may have antimicrobial properties that help in strengthening the innate host defense of tears at the ocular surface. The aim of this study was to investigate the antimicrobial role of human meibomian lipids. Ocular pathogenic bacteria, Staphylococcus aureus 31, Pseudomonas aeruginosa 19, Pseudomonas aeruginosa 20, and Serratia marcescens 35, were grown in the presence and absence of human meibomian lipids in an artificial tear solution at the physiological temperature. Viable counts were obtained to note the number of bacteria surviving the treatment with meibomian lipids. Bacterial cells were imaged using scanning electron microscopy to observe the damages caused by meibomian lipids. Viable count results showed that in the presence of meibomian lipids, growth of all bacteria was considerably lower. Scanning electron microscopy showed that meibomian lipids caused extensive cellular damage to bacteria as manifested in smaller size, loss of aggregation, abnormal phenotype, cellular distortion, damaged cell wall, and cell lysis. This is the first-ever report of the antimicrobial role of human meibomian lipids. These lipids possess antimicrobial properties against both Gram-positive and Gram-negative bacteria and are involved in the innate host defense of tears in protecting the ocular surface against microbial pathogens. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  11. PRGF exerts more potent proliferative and anti-inflammatory effects than autologous serum on a cell culture inflammatory model.

    PubMed

    Anitua, E; Muruzabal, F; de la Fuente, M; Riestra, A; Merayo-Lloves, J; Orive, G

    2016-10-01

    Ocular graft versus host disease (oGVHD) is part of a systemic inflammatory disease that usually affects ocular surface tissues manifesting as a dry eye syndrome. Current treatments provide unsatisfactory results. Blood-derived products, like plasma rich in growth factors (PRGF) emerge as a potential therapy for this disease. The purpose of this study was to evaluate the tissue regeneration and anti-inflammatory capability of PRGF, an autologous platelet enriched plasma eye-drop, compared to autologous serum (AS) obtained from oGVHD patients on ocular surface cells cultured in a pro-inflammatory environment. PRGF and AS were obtained from four GVHD patients. Cell proliferation and inflammation markers, intercellular adhesion molecule-1 (ICAM-1) and cyclooxygenase-2 (COX-2), were measured in corneal and conjunctival fibroblastic cells cultured under pro-inflammatory conditions and after treatment with PRGF or AS eye drops. Moreover, cell proliferation increased after treatment with PRGF and AS, though this enhancement in the case of keratocytes was significantly higher with PRGF. PRGF eye drops showed a significant reduction of both inflammatory markers with respect to the initial inflammatory situation and to the AS treatment. Our results concluded that PRGF exerts more potent regenerative and anti-inflammatory effects than autologous serum on ocular surface fibroblasts treated with pro-inflammatory IL-1β and TNFα. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Mucosal tolerance disruption favors disease progression in an extraorbital lacrimal gland excision model of murine dry eye.

    PubMed

    Guzmán, Mauricio; Keitelman, Irene; Sabbione, Florencia; Trevani, Analía S; Giordano, Mirta N; Galletti, Jeremías G

    2016-10-01

    Dry eye is a highly prevalent immune disorder characterized by a dysfunctional tear film and a Th1/Th17 T cell response at the ocular surface. The specificity of these pathogenic effector T cells remains to be determined, but auto-reactivity is considered likely. However, we have previously shown that ocular mucosal tolerance to an exogenous antigen is disrupted in a scopolamine-induced murine dry eye model and that it is actually responsible for disease progression. Here we report comparable findings in an entirely different murine model of dry eye that involves resection of the extraorbital lacrimal glands but no systemic muscarinic receptor blockade. Upon ocular instillation of ovalbumin, a delayed breakdown in mucosal tolerance to this antigen was observed in excised but not in sham-operated mice, which was mediated by interferon γ- and interleukin 17-producing antigen-specific T cells. Consistently, antigen-specific regulatory T cells were detectable in sham-operated but not in excised mice. As for other models of ocular surface disorders, epithelial activation of the NF-κB pathway by desiccating stress was determinant in the mucosal immune outcome. Underscoring the role of mucosal tolerance disruption in dry eye pathogenesis, its prevention by a topical NF-κB inhibitor led to reduced corneal damage in excised mice. Altogether these results show that surgically originated desiccating stress also initiates an abnormal Th1/Th17 T cell response to harmless exogenous antigens that reach the ocular surface. This event might actually contribute to corneal damage and challenges the conception of dry eye as a strictly autoimmune disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Clusterin in the eye: An old dog with new tricks at the ocular surface.

    PubMed

    Fini, M Elizabeth; Bauskar, Aditi; Jeong, Shinwu; Wilson, Mark R

    2016-06-01

    The multifunctional protein clusterin (CLU) was first described in 1983 as a secreted glycoprotein present in ram rete testis fluid that enhanced aggregation ('clustering') of a variety of cells in vitro. It was also independently discovered in a number of other systems. By the early 1990s, CLU was known under many names and its expression had been demonstrated throughout the body, including in the eye. Its homeostatic activities in proteostasis, cytoprotection, and anti-inflammation have been well documented, however its roles in health and disease are still not well understood. CLU is prominent at fluid-tissue interfaces, and in 1996 it was demonstrated to be the most highly expressed transcript in the human cornea, the protein product being localized to the apical layers of the mucosal epithelia of the cornea and conjunctiva. CLU protein is also present in human tears. Using a preclinical mouse model for desiccating stress that mimics human dry eye disease, the authors recently demonstrated that CLU prevents and ameliorates ocular surface barrier disruption by a remarkable sealing mechanism dependent on attainment of a critical all-or-none concentration in the tears. When the CLU level drops below the critical all-or-none threshold, the barrier becomes vulnerable to desiccating stress. CLU binds selectively to the ocular surface subjected to desiccating stress in vivo, and in vitro to LGALS3 (galectin-3), a key barrier component. Positioned in this way, CLU not only physically seals the ocular surface barrier, but it also protects the barrier cells and prevents further damage to barrier structure. CLU depletion from the ocular surface epithelia is seen in a variety of inflammatory conditions in humans and mice that lead to squamous metaplasia and a keratinized epithelium. This suggests that CLU might have a specific role in maintaining mucosal epithelial differentiation, an idea that can now be tested using the mouse model for desiccating stress. Most excitingly, the new findings suggest that CLU could serve as a novel biotherapeutic for dry eye disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Effect of bilastine upon the ocular symptoms of allergic rhinoconjunctivitis.

    PubMed

    Bartra, J; Mullol, J; Montoro, J; Jáuregui, I; del Cuvillos, A; Dávila, I; Ferrer, M; Sastre, J; Valero, A

    2011-01-01

    Ocular symptoms often accompany allergic rhinitis and can be as or even more bothersome for the patient than the actual nasal symptoms. Ocular manifestations of allergic rhinoconjunctivitis may result from both direct allergen-mediated mast cell stimulation on the surface of the eye and naso-ocular reflexes--histamine being one of the mediators of symptoms onset. An H1 antihistamine would be the first line treatment for allergic conjunctivitis. Since allergic conjunctivitis is always (or almost always) accompanied by nasal symptoms, a second-generation H1 antihistamine administered via oral route is the drug of choice for jointly managing both the nasal and the ocular symptoms--minimizing the impact of the effects inherent to first-generation H, antihistamine, including particularly drowsiness. Bilastine is a new H1 antihistamine with an excellent safety profile, developed for the treatment of allergic rhinoconjunctivitis and urticaria, with potency similar to that of cetirizine and desloratadine, and superior to that of fexofenadine. This new drug has been shown to be effective in controlling the ocular symptoms of allergic rhinoconjunctivitis.

  15. Design and elaboration of freeze-dried PLGA nanoparticles for the transcorneal permeation of carprofen: Ocular anti-inflammatory applications.

    PubMed

    Parra, Alexander; Mallandrich, Mireia; Clares, Beatriz; Egea, María A; Espina, Marta; García, María L; Calpena, Ana C

    2015-12-01

    This work aimed the design and development of poly(lactic-co-glycolic) acid (PLGA) nanoparticles (NPs) for the ocular delivery of Carprofen (CP) by a central rotatable composite design 2(3)+ star. NPs showed adequate size for ocular administration (189.50 ± 1.67 nm), low polydispersity (0.01 ± 0.01), negative charge surface (-22.80 ± 0.66 mV) and optimal entrapment efficiency (74.70 ± 0.95%). Physicochemical analysis confirmed that CP was dispersed inside the NPs. The drug release followed a first order kinetic model providing greater sustained CP release after lyophilization. Ex vivo permeation analysis through isolated rabbit cornea revealed that a sufficient amount of CP was retained in the tissue avoiding excessive permeation and thus, potential systemic levels. Ex vivo ocular tolerance results showed no signs of ocular irritancy, which was also confirmed by in vivo Draize test. In vivo ocular anti-inflammatory efficacy test confirmed an optimal efficacy of NPs and its potential application in eye surgery. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Toluidine Blue 0.05% Vital Staining for the Diagnosis of Ocular Surface Squamous Neoplasia in Kenya.

    PubMed

    Gichuhi, Stephen; Macharia, Ephantus; Kabiru, Joy; Zindamoyen, Alain M'bongo; Rono, Hilary; Ollando, Ernest; Wanyonyi, Leonard; Wachira, Joseph; Munene, Rhoda; Onyuma, Timothy; Jaoko, Walter G; Sagoo, Mandeep S; Weiss, Helen A; Burton, Matthew J

    2015-11-01

    Clinical features are unreliable for distinguishing ocular surface squamous neoplasia (OSSN) from benign conjunctival lesions. To evaluate the adverse effects, accuracy, and interobserver variation of toluidine blue 0.05% vital staining in distinguishing OSSN, confirmed by histopathology, from other conjunctival lesions. Cross-sectional study in Kenya from July 2012 through July 2014 of 419 adults with suspicious conjunctival lesions. Pregnant and breastfeeding women were excluded. Comprehensive ophthalmic slitlamp examination was conducted. Vital staining with toluidine blue 0.05% aqueous solution was performed before surgery. Initial safety testing was conducted on large tumors scheduled for exenteration looking for corneal toxicity on histology before testing smaller tumors. We asked about pain or discomfort after staining and evaluated the cornea at the slitlamp for epithelial defects. Lesions were photographed before and after staining. Diagnosis was confirmed by histopathology. Six examiners assessed photographs from a subset of 100 consecutive participants for staining and made a diagnosis of OSSN vs non-OSSN. Staining was compared with histopathology to estimate sensitivity, specificity, and predictive values. Adverse effects were enumerated. Interobserver agreement was estimated using the κ statistic. A total of 143 of 419 participants (34%) had OSSN by histopathology. The median age of all participants was 37 years (interquartile range, 32-45 years) and 278 (66%) were female. A total of 322 of the 419 participants had positive staining while 2 of 419 were equivocal. There was no histological evidence of corneal toxicity. Mild discomfort was reported by 88 (21%) and mild superficial punctate keratopathy seen in 7 (1.7%). For detecting OSSN, toluidine blue had a sensitivity of 92% (95% CI, 87%-96%), specificity of 31% (95% CI, 25%-36%), positive predictive value of 41% (95% CI, 35%-46%), and negative predictive value of 88% (95% CI, 80%-94%). Interobserver agreement was substantial for staining (κ = 0.76) and moderate for diagnosis (κ = 0.40). With the high sensitivity and low specificity for OSSN compared with histopathology among patients with conjunctival lesions, toluidine blue 0.05% vital staining is a good screening tool. However, it is not a good diagnostic tool owing to a high frequency of false-positives. The high negative predictive value suggests that a negative staining result indicates that OSSN is relatively unlikely.

  17. Incomplete response to artificial tears is associated with features of neuropathic ocular pain.

    PubMed

    Galor, Anat; Batawi, Hatim; Felix, Elizabeth R; Margolis, Todd P; Sarantopoulos, Konstantinos D; Martin, Eden R; Levitt, Roy C

    2016-06-01

    Artificial tears are first-line therapy for patients with dry eye symptoms. It is not known, however, which patient factors associate with a positive response to therapy. The purpose of this study was to evaluate whether certain ocular and systemic findings are associated with a differential subjective response to artificial tears. Cross-sectional study of 118 individuals reporting artificial tears use (hypromellose 0.4%) to treat dry eye-associated ocular pain. An evaluation was performed to assess dry eye symptoms (via the dry eye questionnaire 5 and ocular surface disease index), ocular and systemic (non-ocular) pain complaints and ocular signs (tear osmolarity, tear breakup time, corneal staining, Schirmer testing with anaesthesia, and eyelid and meibomian gland assessment). The main outcome measures were factors associated with differential subjective response to artificial tears. By self-report, 23 patients reported no improvement, 73 partial improvement and 22 complete improvement in ocular pain with artificial tears. Patients who reported no or partial improvement in pain with artificial tears reported higher levels of hot-burning ocular pain and sensitivity to wind compared with those with complete improvement. Patients were also asked to rate the intensity of systemic pain elsewhere in the body (other than the eye). Patients who reported no or incomplete improvement with artificial tears had higher systemic pain scores compared with those with complete improvement. Both ocular and systemic (non-ocular) pain complaints are associated with a differential subjective response to artificial tears. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Vision-Related Quality of Life in Patients with Ocular Graft-versus-Host Disease.

    PubMed

    Saboo, Ujwala S; Amparo, Francisco; Abud, Tulio B; Schaumberg, Debra A; Dana, Reza

    2015-08-01

    To assess the vision-related quality of life (QOL) in a cohort of patients with ocular graft-versus-host disease (GVHD). Prospective study. Eighty-four patients diagnosed with chronic ocular GVHD. We assessed the vision-related QOL with the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). The symptoms of ocular GVHD were assessed using the Ocular Surface Disease Index (OSDI) and Symptom Assessment in Dry Eye (SANDE) questionnaires. We assessed vision-related QOL with the NEI-VFQ-25 and compared the scores obtained from patients with ocular GVHD with those from a healthy population. In the ocular GVHD population, we also evaluated the associations between the NEI-VFQ-25 and the dry eye symptoms measured by the OSDI and SANDE questionnaires, age, duration of disease, best-corrected visual acuity (BCVA), corneal fluorescein staining (CFS), tear break-up time, and Schirmer test. The mean composite NEI-VFQ-25 score in patients with ocular GVHD was 76.5±17. Compared with healthy subjects, patients with ocular GVHD reported reduced scores on all NEI-VFQ-25 subscales (each P < 0.001) with the exception of color vision (P = 0.11). The NEI-VFQ-25 composite scores significantly correlated with OSDI (R = -0.81, P < 0.001), SANDE (R = -0.56, P < 0.001), CFS (R = -0.36, P = 0.001), and BCVA (R = -0.30, P = 0.004). Patients with ocular GVHD experience measurable impairment of vision-related QOL. This study highlights the impact of ocular GVHD on the vision-related QOL, and thus the importance of comprehensive diagnosis and treatment of this condition. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Vision-Related Quality of Life in Patients with Ocular Graft-versus-host Disease

    PubMed Central

    Saboo, Ujwala S; Amparo, Francisco; Abud, Tulio B; Schaumberg, Debra A; Dana, Reza

    2015-01-01

    Objective To assess the vision-related quality of life in a cohort of patients with ocular graft-versus-host disease (GVHD). Design Prospective study. Participants Eighty-four patients diagnosed with chronic ocular GVHD Methods We assessed the vision-related quality of life with the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25). The symptoms of ocular GVHD were assessed using the Ocular Surface Disease Index (OSDI) and Symptom Assessment in Dry Eye (SANDE) questionnaires. Main outcome measures We assessed vision-related quality of life with NEI-VFQ-25 and compared the scores obtained from patients with ocular GVHD to those from a healthy population. In the ocular GVHD population, we also evaluated the associations between the NEI-VFQ-25 and dry eye symptoms measured by OSDI and SANDE questionnaires, age, duration of disease, best-corrected visual acuity, corneal fluorescein staining, tear break-up time, and Schirmer test. Results The mean composite NEI-VFQ-25 score in patients with ocular GVHD was 76.5 ± 17. Compared to healthy subjects, ocular GVHD patients reported reduced scores on all NEI-VFQ-25 subscales (each P < 0.001) with exception of color vision (P = 0.11). The NEI-VFQ-25 composite scores significantly correlated with OSDI (R = −0.81, P < 0.001), SANDE (R = −0.56, P < 0.001), corneal fluorescein staining (R = −0.36, P = 0.001) and best-corrected visual acuity (R = −0.30, P = 0.004). Conclusion Patients with ocular GVHD experience measurable impairment of vision-related quality of life. This study highlights the impact of ocular GVHD on the vision-related quality of life, and hence the importance of comprehensive diagnosis and treatment of this condition. PMID:26001816

  20. Corneal Sensitivity in Tear Dysfunction and its Correlation with Clinical Parameters and Blink Rate

    PubMed Central

    Rahman, Effie Z.; Lam, Peter K.; Chu, Chia-Kai; Moore, Quianta; Pflugfelder, Stephen C.

    2015-01-01

    Purpose To compare corneal sensitivity in tear dysfunction due to a variety of causes using contact and non-contact esthesiometers and to evaluate correlations between corneal sensitivity, blink rate and clinical parameters. Design Comparative observational case series. Methods Ten normal and 33 subjects with tear dysfunction [meibomian gland disease (n = 11), aqueous tear deficiency (n = 10) - without (n = 7) and with (n = 3) Sjögren syndrome (SS) and conjunctivochalasis (n = 12)] were evaluated. Corneal sensitivity was measured with Cochet-Bonnet and air jet esthesiometers and blink rate by electromyelography. Eye irritation symptoms, tear meniscus height, tear break-up time (TBUT), and corneal and conjunctival dye staining were measured. Between group means were compared and correlations calculated. Results Compared with control (Cochet-Bonnet 5.45 mm, air esthesiometer 3.62 mg), mean sensory thresholds were significantly higher in aqueous tear deficiency using either Cochet-Bonnet (3.6 mm; P = 0.003) or air (11.7 mg; P = 0.046) esthesiometers, but were not significantly different in the other groups. Reduced corneal sensitivity significantly correlated with more rapid TBUT and blink rate, and greater irritation and ocular surface dye staining with one or both esthesiometers. Mean blink rates were significantly higher in both aqueous tear deficiency and conjunctivochalasis compared with control. Among all subjects, blink rate positively correlated with ocular surface staining and irritation and inversely correlated with TBUT. Conclusion Amongst conditions causing tear dysfunction, reduced corneal sensitivity is associated with greater irritation, tear instability, ocular surface disease and blink rate. Rapid blinking is associated with worse ocular surface disease and tear stability. PMID:26255576

  1. [Eye-associated lymphoid tissue (EALT) is continuously spread throughout the ocular surface from the lacrimal gland to the lacrimal drainage system].

    PubMed

    Knop, E; Knop, N

    2003-11-01

    Components of the mucosal immune system (MALT) have been identified in the conjunctiva (as CALT) and the lacrimal drainage system (as LDALT). Their structural and functional relation with the established immune protection by the lacrimal gland is unclear. Macroscopically normal and complete tissues of the conjunctiva, lacrimal drainage system and lacrimal gland from human body donors were investigated by analysis of translucent whole mounts, and using histology, immunohistology as well as scanning and transmission electron microscopy. A typical diffuse lymphoid tissue, composed of effector cells of the immune system (T-lymphocytes and IgA producing plasma cells) under an epithelium that contains the IgA transporter SC, is not isolated in the conjunctiva and lacrimal drainage system. It is anatomically continuous from the lacrimal gland along its excretory ducts into the conjunctiva and from there via the lacrimal canaliculi into the lacrimal drainage system. Lymphoid follicles occur in a majority (about 60%) and with bilateral symmetry. The topography of CALT corresponds to the position of the cornea in the closed eye. These results show that the MALT of the lacrimal gland, conjunctiva and lacrimal drainage system constitute an anatomical and functional unit for immune protection of the ocular surface. Therefore it should be integrated as an "eye-associated lymphoid tissue" (EALT) into the MALT system of the body. EALT can detect ocular surface antigens by the lymphoid follicles and can supply other organs and the ocular surface including the lacrimal gland with specific effector cells via the regulated recirculation of lymphoid cells.

  2. Efficacy of punctal occlusion in management of dry eyes after laser in situ keratomileusis for myopia.

    PubMed

    Alfawaz, Abdullah M; Algehedan, Saeed; Jastaneiah, Sabah S; Al-Mansouri, Samir; Mousa, Ahmed; Al-Assiri, Abdullah

    2014-03-01

    To evaluate the effect of punctal plug use in preventing dry eye after laser in situ keratomileusis (LASIK). A randomized clinical trial at a tertiary eye care center, Riyadh, Saudi Arabia. Participants underwent LASIK for myopia in both eyes and a lower punctal occlusion in one eye only while the other eye served as control. Both eyes received the same postoperative medications except for lubricant duration (subject eye: four times per day for one week; control eye: four times per day for 6 months). Participants were evaluated at 1 week, 2, and 6 months after surgery for signs and symptoms of dry eye. The main outcome measures were visual acuity; ocular surface parameters; and Ocular Surface Disease Index questionnaire. Seventy-eight eyes of 39 patients were included in this study. The Ocular Surface Disease Index scores of eyes with punctal plugs were better at all follow-up visits, and the differences between both eyes were statistically significant (1 week, p < 0.0001; 2 months, p < 0.0001; 6 months, p = 0.008). At the final follow-up visit, the percentage of normal eyes was higher in eyes with punctal plugs for all ocular surface parameters (Schirmer 1 test, 94.9%; tear breakup time, 77.8%; punctate epithelial keratitis score, 71.8%) compared to eyes without occlusion (Schirmer 1 test, 92.3%; tear breakup time, 58.3%; punctate epithelial keratitis score, 53.8%); however, such differences were not statistically significant. Punctal plug insertion after LASIK surgeries may minimize the need for frequent lubricant application and hence improve patient satisfaction.

  3. Tear cytokine profile as a noninvasive biomarker of inflammation for ocular surface diseases: standard operating procedures.

    PubMed

    Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny

    2013-12-23

    To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.

  4. TFOS DEWS II pain and sensation report

    PubMed Central

    Belmonte, Carlos; Nichols, Jason J.; Cox, Stephanie M.; Brock, James A.; Begley, Carolyn G.; Bereiter, David A.; Dartt, Darlene A.; Galor, Anat; Hamrah, Pedram; Ivanusic, Jason J.; Jacobs, Deborah S.; McNamara, Nancy A.; Rosenblatt, Mark I.; Stapleton, Fiona; Wolffsohn, James S.

    2017-01-01

    Pain associated to mechanical and chemical irritation of the eye surface is mediated by trigeminal ganglia mechano- and polymodal nociceptor neurons while cold thermoreceptors detect wetness and reflexly maintain basal tear production and blinking rate. These neurons project into two regions of the trigeminal brain stem nuclear complex: ViVc, activated by changes in the moisture of the ocular surface and VcC1, mediating sensory-discriminative aspects of ocular pain and reflex blinking. ViVc ocular neurons project to brain regions that control lacrimation and spontaneous blinking and to the sensory thalamus. Secretion of the main lacrimal gland is regulated dominantly by autonomic parasympathetic nerves, reflexly activated by eye surface sensory nerves. These also evoke goblet cell secretion through unidentified efferent fibers. Neural pathways involved in the regulation of Meibonian gland secretion or mucins release have not been identified. In dry eye disease, reduced tear secretion leads to inflammation and peripheral nerve damage. Inflammation causes sensitization of polymodal and mechano-nociceptor nerve endings and an abnormal increase in cold thermoreceptor activity, altogether evoking dryness sensations and pain. Long-term inflammation and nerve injury alter gene expression of ion channels and receptors at terminals and cell bodies of trigeminal ganglion and brainstem neurons, changing their excitability, connectivity and impulse firing. Perpetuation of molecular, structural and functional disturbances in ocular sensory pathways ultimately leads to dysestesias and neuropathic pain referred to the eye surface. Pain can be assessed with a variety of questionaires while the status of corneal nerves is evaluated with esthesiometry and with in vivo confocal microscopy. PMID:28736339

  5. Ocular surface changes in limbal stem cell deficiency caused by chemical injury: a histologic study of excised pannus from recipients of cultured corneal epithelium.

    PubMed

    Fatima, A; Iftekhar, G; Sangwan, V S; Vemuganti, G K

    2008-09-01

    To report histopathologic changes of the ocular surface pannus in patients with severe limbal stem cell deficiency (LSCD). Corneal and conjunctival pannus tissues from 29 patients undergoing ocular reconstruction with cultured limbal cell transplantation were included. The medical records of these patients were reviewed for demographics, aetiologic diagnosis, type of injury, interval between the initial insult and excision of pannus, and medical history involving human amniotic membrane (HAM) or limbal transplantation. The paraffin-embedded tissues were reviewed for epithelial changes, type-degree of fibrosis, degenerative changes, vascular changes, conjunctivalization of corneal surface, and evidence of residual HAM. We attempted a clinicopathologic correlation to understand the pathogenesis of pannus formation in LSCD. The 29 tissues were from 29 eyes of patients with primary aetiology of chemical burn in 89.6% (undetermined in 10.4%) of cases. The pannus showed epithelial hyperplasia in 62%, active fibrosis in 66%, severe inflammation in 21%, giant cell reaction in 28%, and stromal calcification in 14% cases. Goblet cells were seen over the cornea in 64% cases; their absence was associated with squamous metaplasia of the conjunctiva and with long duration of insult. Evidence of residual HAM was noted in 42% cases. The commonest cause of severe LSCD is alkali-induced injury. Goblet cells over the cornea were seen in 60% of cases. HAM used for ocular surface reconstruction could persist for long periods within the corneal pannus, thus raising the need for further studies with long-term follow-up.

  6. [Research progress of conscious pain and neurosensory abnormalities in dry eye disease].

    PubMed

    Lin, X; Liu, Z L; Wu, J L; Liu, Z G

    2018-02-11

    Dry eye is one of the most common ocular problems in ophthalmology clinic. With the change of social environment and people's life style, the prevalence of dry eye disease is increasing. Currently, the diagnosis criteria for dry eye is controversial, diagnosis of dry eye mainly rely on the comprehensive assessment of symptoms and the presence of associated ocular surface signs. However, previous studies have shown a poor correlation between dry eye symptoms and objective clinical signs in patients. Recent studies have found that neuropathic pain plays an important role in the occurrence of discordance between symptoms and signs in dry eye disease. The purpose of this paper is to present the conception of pain, the distribution and function of sensory nerves in ocular surface, the prevalence and mechanism of neuropathic pain and analgesic treatment in dry eye disease. (Chin J Ophthalmol, 2018, 54: 144-148) .

  7. Correlation between acute conjunctivitis and Asian dust on ocular surfaces.

    PubMed

    Ko, Ryota; Hayashi, Masahiko; Hayashi, Hideyuki; Hayashi, Kazue; Kato, Hitoshi; Kurata, Yoshinori; Fuchino, Yuki; Nakamichi, Toshifumi; Migita, Hironori; Yano, Hiroko; Sakata, Tetsuya; Uchio, Eiichi

    2016-01-01

    The aim of this study was to determine the presence of Asian dust particles (ADP) in patients suffering from conjunctivitis and its correlation with clinical scores for conjunctivitis. Forty-five patients from the Fukuoka area who were newly diagnosed acute conjunctivitis were selected. The degrees of inflammatory reaction, itchy sensation, hyperemia, eye discharge, and foreign body sensation were clinically recorded and scored. Eyes were washed with physiological solution. Solid particles collected from the washing solution were observed using a scanning electron microscope. Of the 45 samples, 44 were positive for the elements silicon (Si) and aluminum (Al), which are components of ambient Asian dust. Higher conjunctivitis scores were found in the subgroup in which the Asian dust/whole particle ratio was greater than average. This is the first apparent report on the correlation between amount of ADP exposure at the ocular surface and severity of ocular symptoms.

  8. Silibinin, dexamethasone, and doxycycline as potential therapeutic agents for treating vesicant-inflicted ocular injuries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tewari-Singh, Neera, E-mail: Neera.Tewari-Singh@ucdenver.edu; Jain, Anil K., E-mail: Anil.Jain@ucdenver.edu; Inturi, Swetha, E-mail: Swetha.Inturi@ucdenver.edu

    There are no effective and approved therapies against devastating ocular injuries caused by vesicating chemical agents sulfur mustard (SM) and nitrogen mustard (NM). Herein, studies were carried out in rabbit corneal cultures to establish relevant ocular injury biomarkers with NM for screening potential efficacious agents in laboratory settings. NM (100 nmol) exposure of the corneas for 2 h (cultured for 24 h), showed increases in epithelial thickness, ulceration, apoptotic cell death, epithelial detachment microbullae formation, and the levels of VEGF, cyclooxygenase-2 (COX-2) and matrix metalloproteinase-9 (MMP-9). Employing these biomarkers, efficacy studies were performed with agent treatments 2 h and everymore » 4 h thereafter, for 24 h following NM exposure. Three agents were evaluated, including prescription drugs dexamethasone (0.1%; anti-inflammatory steroid) and doxycycline (100 nmol; antibiotic and MMP inhibitor) that have been studied earlier for treating vesicant-induced eye injuries. We also examined silibinin (100 μg), a non-toxic natural flavanone found to be effective in treating SM analog-induced skin injuries in our earlier studies. Treatments of doxycycline + dexamethasone, and silibinin were more effective than doxycycline or dexamethasone alone in reversing NM-induced epithelial thickening, microbullae formation, apoptotic cell death, and MMP-9 elevation. However, dexamethasone and silibinin alone were more effective in reversing NM-induced VEGF levels. Doxycycline, dexamethasone and silibinin were all effective in reversing NM-induced COX-2 levels. Apart from therapeutic efficacy of doxycycline and dexamethasone, these results show strong multifunctional efficacy of silibinin in reversing NM-induced ocular injuries, which could help develop effective and safe therapeutics against ocular injuries by vesicants. -- Highlights: ► Established injury biomarkers in rabbit corneal culture with nitrogen mustard (NM) ► This NM model is a cost effective system to evaluate and optimize therapeutics. ► Show that doxycycline and dexamethasone reduce NM-caused ocular injuries ► Demonstrate that silibinin effectively reverses NM-caused ocular injury endpoints ► Suggest optimization of identified agents against ocular injuries by vesicants.« less

  9. Effects of lodoxamide (LOD), disodium cromoglycate (DSCG) and N-acetyl-aspartyl-glutamate sodium salt (NAAGA) on ocular active anaphylaxis.

    PubMed

    Goldschmidt, P; Luyckx, J

    1996-04-01

    LOD, DSCG and NAAGA eye-drops were evaluated on experimentally-induced ocular active anaphylaxis in guinea pigs. Twelve animals per group were sensitized with egg albumin i.p. and challenged on the surface of the eye 14 days later. Two days before challenge, animals were treated with LOD, DSCG or NAAGA 4 times a day. Permeability indexes were calculated after intracardiac injection of Evans Blue. No effect on ocular active anaphylaxis was found with LOD nor with DSCG. NAAGA was able to significantly reduce blood-eye permeability indexes.

  10. Surface modification of model hydrogel contact lenses with hyaluronic acid via thiol-ene "click" chemistry for enhancing surface characteristics.

    PubMed

    Korogiannaki, Myrto; Zhang, Jianfeng; Sheardown, Heather

    2017-10-01

    Discontinuation of contact lens wear as a result of ocular dryness and discomfort is extremely common; as many as 26% of contact lens wearers discontinue use within the first year. While patients are generally satisfied with conventional hydrogel lenses, improving on-eye comfort continues to remain a goal. Surface modification with a biomimetic, ocular friendly hydrophilic layer of a wetting agent is hypothesized to improve the interfacial interactions of the contact lens with the ocular surface. In this work, the synthesis and characterization of poly(2-hydroxyethyl methacrylate) surfaces grafted with a hydrophilic layer of hyaluronic acid are described. The immobilization reaction involved the covalent attachment of thiolated hyaluronic acid (20 kDa) on acrylated poly(2-hydroxyethyl methacrylate) via nucleophile-initiated Michael addition thiol-ene "click" chemistry. The surface chemistry of the modified surfaces was analyzed by Fourier transform infrared spectroscopy-attenuated total reflectance and X-ray photoelectron spectroscopy. The appearance of N (1s) and S (2p) peaks on the low resolution X-ray photoelectron spectroscopy spectra confirmed successful immobilization of hyaluronic acid. Grafting hyaluronic acid to the poly(2-hydroxyethyl methacrylate) surfaces decreased the contact angle, the dehydration rate, and the amount of nonspecific sorption of lysozyme and albumin in comparison to pristine hydrogel materials, suggesting the development of more wettable surfaces with improved water-retentive and antifouling properties, while maintaining optical transparency (>92%). In vitro testing also showed excellent viability of human corneal epithelial cells with the hyaluronic acid-grafted poly(2-hydroxyethyl methacrylate) surfaces. Hence, surface modification with hyaluronic acid via thiol-ene "click" chemistry could be useful in improving contact lens surface properties, potentially alleviating symptoms of contact lens related dryness and discomfort during wear.

  11. Neural Regulation of Lacrimal Gland Secretory Processes: Relevance in Dry Eye Diseases

    PubMed Central

    Dartt, Darlene A.

    2013-01-01

    The lacrimal gland is the major contributor to the aqueous layer of the tear film which consists of water, electrolytes and proteins. The amount and composition of this layer is critical for the health, maintenance, and protection of the cells of the cornea and conjunctiva (the ocular surface). Small changes in the concentration of tear electrolytes have been correlated with dry eye syndrome. While the mechanisms of secretion of water, electrolytes and proteins from the lacrimal gland differ, all three are under tight neural control. This allows for a rapid response to meet the needs of the cells of the ocular surface in response to environmental conditions. The neural response consists of the activation of the afferent sensory nerves in the cornea and conjunctiva to stimulate efferent parasympathetic and sympathetic nerves that innervate the lacrimal gland. Neurotransmitters are released from the stimulated parasympathetic and sympathetic nerves that cause secretion of water, electrolytes, and proteins from the lacrimal gland and onto the ocular surface. This review focuses on the neural regulation of lacrimal gland secretion under normal and dry eye conditions. PMID:19376264

  12. [Hyperosmolarity: Intracellular effects and implication in dry eye disease].

    PubMed

    Warcoin, E; Clouzeau, C; Brignole-Baudouin, F; Baudouin, C

    2016-09-01

    Dry eye disease is a multifactorial disease affecting the lacrimal functional unit and which has a significant impact on the quality of life of patients. This pathology works as a vicious circle at the ocular surface in which hyperosmolarity of the tear film plays a key role. This review intends to describe the different reported intracellular effects induced by hyperosmolarity in cells: alteration of cytoskeleton, cell cycle slowdown, adaptation mechanisms triggered as restoration of cell volume and accumulation of compatible osmolytes, the crucial role of the osmoprotectant factor Nuclear Factor of the Activated T cells-5 (NFAT5), apoptosis, as well as oxidative stress and inflammatory responses caused by this particular condition. Reported effects of hyperosmolarity in the experimental studies specific of dry eye disease concerning ocular surface cells will be described in parallel. Indeed, these data allow to understand a part of the pathophysiology of the disease, and specially the links between tear hyperosmolarity and inflammation of the ocular surface, the second key of the pathology phenomenon. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. An assessment of the pattern of spontaneous eyeblink activity under the influence of topical ocular anaesthesia.

    PubMed

    Naase, Taher; Doughty, Michael J; Button, Norman F

    2005-04-01

    To determine whether there is a change in the pattern of human eyeblink events under topical ocular anaesthesia. Forty male subjects, aged between 19 and 52 years and with no significant ocular surface disease, were recruited. Their spontaneous eyeblink activity, in primary eye gaze position and in silence, was recorded for 5-min periods, before and after instillation of benoxinate 0.4% eyedrops. The surface anaesthesia was confirmed by aesthesiometry. The spontaneous eyeblink rate (SEBR) decreased from 9.1+/-4.0 blinks/min to an average of 5.7+/-3.3 blinks/min, with 37 subjects showing a decreased eyeblink rate under anaesthesia. Three blink patterns were observed before anaesthesia (symmetrical, J-type and I-type) and these were essentially unchanged under anaesthesia. These studies confirm that the SEBR is usually reduced under surface anaesthesia (so is sensitive to exogenous control) but the pattern of the eyeblink activity is unchanged (so is less sensitive to exogenous control). The removal of exogenous stimuli by anaesthesia does not shift the eyeblink pattern to a single type, so indicates endogenous control.

  14. Real-time dose calculation and visualization for the proton therapy of ocular tumours

    NASA Astrophysics Data System (ADS)

    Pfeiffer, Karsten; Bendl, Rolf

    2001-03-01

    A new real-time dose calculation and visualization was developed as part of the new 3D treatment planning tool OCTOPUS for proton therapy of ocular tumours within a national research project together with the Hahn-Meitner Institut Berlin. The implementation resolves the common separation between parameter definition, dose calculation and evaluation and allows a direct examination of the expected dose distribution while adjusting the treatment parameters. The new tool allows the therapist to move the desired dose distribution under visual control in 3D to the appropriate place. The visualization of the resulting dose distribution as a 3D surface model, on any 2D slice or on the surface of specified ocular structures is done automatically when adapting parameters during the planning process. In addition, approximate dose volume histograms may be calculated with little extra time. The dose distribution is calculated and visualized in 200 ms with an accuracy of 6% for the 3D isodose surfaces and 8% for other objects. This paper discusses the advantages and limitations of this new approach.

  15. Potential Role of Induced Pluripotent Stem Cells (IPSCs) for Cell-Based Therapy of the Ocular Surface

    PubMed Central

    Casaroli-Marano, Ricardo P.; Nieto-Nicolau, Núria; Martínez-Conesa, Eva M.; Edel, Michael; Álvarez-Palomo, Ana B.

    2015-01-01

    The integrity and normal function of the corneal epithelium are crucial for maintaining the cornea’s transparency and vision. The existence of a cell population with progenitor characteristics in the limbus maintains a dynamic of constant epithelial repair and renewal. Currently, cell-based therapies for bio replacement—cultured limbal epithelial transplantation (CLET) and cultured oral mucosal epithelial transplantation (COMET)—present very encouraging clinical results for treating limbal stem cell deficiency (LSCD) and restoring vision. Another emerging therapeutic approach consists of obtaining and implementing human progenitor cells of different origins in association with tissue engineering methods. The development of cell-based therapies using stem cells, such as human adult mesenchymal or induced pluripotent stem cells (IPSCs), represent a significant breakthrough in the treatment of certain eye diseases, offering a more rational, less invasive, and better physiological treatment option in regenerative medicine for the ocular surface. This review will focus on the main concepts of cell-based therapies for the ocular surface and the future use of IPSCs to treat LSCD. PMID:26239129

  16. Corneal and conjunctival drug permeability: Systematic comparison and pharmacokinetic impact in the eye.

    PubMed

    Ramsay, Eva; Del Amo, Eva M; Toropainen, Elisa; Tengvall-Unadike, Unni; Ranta, Veli-Pekka; Urtti, Arto; Ruponen, Marika

    2018-07-01

    On the surface of the eye, both the cornea and conjunctiva are restricting ocular absorption of topically applied drugs, but barrier contributions of these two membranes have not been systemically compared. Herein, we studied permeability of 32 small molecular drug compounds across an isolated porcine cornea and built a quantitative structure-property relationship (QSPR) model for the permeability. Corneal drug permeability (data obtained for 25 drug molecules) showed a 52-fold range in permeability (0.09-4.70 × 10 -6  cm/s) and the most important molecular descriptors in predicting the permeability were hydrogen bond donor, polar surface area and halogen ratio. Corneal permeability values were compared to their conjunctival drug permeability values. Ocular drug bioavailability and systemic absorption via conjunctiva were predicted for this drug set with pharmacokinetic calculations. Drug bioavailability in the aqueous humour was simulated to be <5% and trans-conjunctival systemic absorption was 34-79% of the dose. Loss of drug across the conjunctiva to the blood circulation restricts significantly ocular drug bioavailability and, therefore, ocular absorption does not increase proportionally with the increasing corneal drug permeability. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Induced pluripotent stem cell-derived limbal epithelial cells (LiPSC) as a cellular alternative for in vitro ocular toxicity testing.

    PubMed

    Aberdam, Edith; Petit, Isabelle; Sangari, Linda; Aberdam, Daniel

    2017-01-01

    Induced pluripotent stem cells hold great potential to produce unlimited amount of differentiated cells as cellular source for regenerative medicine but also for in vitro drug screening and cytotoxicity tests. Ocular toxicity testing is mandatory to evaluate the risks of drugs and cosmetic products before their application to human patients by preventing eye irritation or insult. Since the global ban to use animals, many human-derived alternatives have been proposed, from ex-vivo enucleated postmortem cornea, primary corneal cell culture and immortalized corneal epithelial cell lines. All of them share limitations for their routine use. Using an improved protocol, we derived limbal epithelial cells from human induced pluripotent stem cells, named LiPSC, that are able to be passaged and differentiate further into corneal epithelial cells. Comparative RT-qPCR, immunofluorescence staining, flow cytometry analysis and zymography assays demonstrate that LiPSC are morphologically and molecularly similar to the adult stem cells. Moreover, contrary to HCE, LiPSC and primary limbal cells display similarly sensitive to cytotoxicity treatment among passages. Our data strongly suggest that LiPSC could become a powerful alternative cellular model for cosmetic and drug tests.

  18. Induced pluripotent stem cell-derived limbal epithelial cells (LiPSC) as a cellular alternative for in vitro ocular toxicity testing

    PubMed Central

    Aberdam, Edith; Petit, Isabelle; Sangari, Linda

    2017-01-01

    Induced pluripotent stem cells hold great potential to produce unlimited amount of differentiated cells as cellular source for regenerative medicine but also for in vitro drug screening and cytotoxicity tests. Ocular toxicity testing is mandatory to evaluate the risks of drugs and cosmetic products before their application to human patients by preventing eye irritation or insult. Since the global ban to use animals, many human-derived alternatives have been proposed, from ex-vivo enucleated postmortem cornea, primary corneal cell culture and immortalized corneal epithelial cell lines. All of them share limitations for their routine use. Using an improved protocol, we derived limbal epithelial cells from human induced pluripotent stem cells, named LiPSC, that are able to be passaged and differentiate further into corneal epithelial cells. Comparative RT-qPCR, immunofluorescence staining, flow cytometry analysis and zymography assays demonstrate that LiPSC are morphologically and molecularly similar to the adult stem cells. Moreover, contrary to HCE, LiPSC and primary limbal cells display similarly sensitive to cytotoxicity treatment among passages. Our data strongly suggest that LiPSC could become a powerful alternative cellular model for cosmetic and drug tests. PMID:28640863

  19. A Phase 1 study of PF-04929113 (SNX-5422), an orally bioavailable heat shock protein 90 inhibitor in patients with refractory solid tumor malignancies and lymphomas

    PubMed Central

    Rajan, Arun; Kelly, Ronan J.; Trepel, Jane B.; Kim, Yeong Sang; Alarcon, Sylvia V.; Kummar, Shivaani; Gutierrez, Martin; Crandon, Sonja; Zein, Wadih M.; Jain, Lokesh; Mannargudi, Baskar; Figg, William D.; Houk, Brett E.; Shnaidman, Michael; Brega, Nicoletta; Giaccone, Giuseppe

    2011-01-01

    Purpose To determine the maximum tolerated dose (MTD), toxicities, and pharmacokinetic-pharmacodynamic profile of the heat shock protein 90 (Hsp90) inhibitor PF-04929113 (SNX-5422) in patients with advanced solid tumors and lymphomas. Methods This was a single institution, phase I, dose-escalation study of PF-04929113 dosed twice-weekly. Endpoints included determination of dose-limiting toxicities (DLT), MTD, the safety profile of PF-04929113, pharmacodynamic assessment of PF-04929113 on Hsp70 induction, pharmacokinetic (PK) analysis of PF 04928473 (SNX-2112) and its prodrug PF-04929113 and assessment of response. Results Thirty three patients with advanced malignancies were treated. Dose escalation was continued up to 177 mg/m2 administered orally twice a week. One DLT (non-septic arthritis) was noted. No grade 4 adverse events (AEs) were seen; grade 3 AEs included diarrhea (9%), non-septic arthritis (3%), AST elevation (3%) and thrombocytopenia (3%). No objective responses were seen in 32 evaluable patients. Fifteen patients (47%) had stable disease; 17 patients (53%) had progressive disease. PK data revealed rapid absorption, hepatic and extra-hepatic clearance, extensive tissue binding and almost linear pharmacokinetics of the active drug PF 04928473. PD studies confirmed inhibition of Hsp90 and a linear correlation between PK parameters and Hsp70 induction. Conclusions PF-04929113 administered orally twice weekly is well tolerated and inhibits its intended target Hsp90. No objective responses were seen but long lasting stabilizations were obtained. Although no clinically significant drug-related ocular toxicity was seen in this study the development of PF-04929113 has been discontinued due to ocular toxicity seen in animal models and in a separate phase I study. PMID:21908572

  20. Correlations among ocular surface temperature difference value, the tear meniscus height, Schirmer's test and fluorescein tear film break up time.

    PubMed

    Su, Tai Yuan; Ho, Wei Ting; Lu, Chien Yi; Chang, Shu Wen; Chiang, Huihua Kenny

    2015-04-01

    To report the use of a thermographer for measuring ocular surface temperature, and to evaluate the correlation among the obtained temperature difference values (TDVs) and dry eye parameters (tear meniscus height (TMH); Schirmer's test results; fluorescent tear breakup time (FTBUT)). Forty-three participants (age 40.2±14.7 years; range 21-67 years) from Far Eastern Memorial Hospital, Taiwan were recruited for the study. The surface temperature was measured at the centre of the ocular surface for 4 s after blinking. TDV was defined as the change in corneal surface temperature relative to that of the preceding eye opening, where TDV01, TDV02, TDV03, and TDV04 represent the values obtained 1, 2, 3, and 4 s after blinking, respectively. Anterior segment optical coherence tomography (AS-OCT) was employed to measure the lower TMH. Schirmer's test with topical anaesthetic was conducted to measure the basal tear secretion. The FTBUT was recorded using a digital camera. TDV measurement exhibited high reliability (intraclass correlation coefficient=0.91). TDV03 exhibited the highest significance and strongest positive correlation with the TMH (r=0.52, p=0.0003) and Schirmer's test value (r=0.39, p=0.008), whereas the TDV03-FTBUT correlation was non-significant. Age correlated negatively and significantly with the TDV (r= -0.35, p=0.021), TMH (r= -0.33, p=0.031), and Schirmer's test value (r= -0.31, p=0.044). TDV03 remained significantly correlated with the TMH and Schirmer's test value after adjustment for age. The thermographer was effective in capturing temperature changes in the ocular surface. The temperature difference 3 s after blinking appears to be correlated with lower TMH and Schirmer test values. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. A review of preserved and preservative-free prostaglandin analogues for the treatment of open-angle glaucoma and ocular hypertension.

    PubMed

    Hommer, A

    2010-06-01

    Glaucoma affects an increasing number of people worldwide and is the second leading cause of blindness. The aim of antiglaucoma therapy is to maintain a patient's visual function and quality of life. Prostaglandin analogues are first-line topical antiglaucoma therapy. They are effective at lowering intraocular pressure (IOP) and are generally well tolerated, with fewer systemic adverse events compared with the other classes. However, the use of prostaglandin analogues can be associated with ocular adverse effects, such as stinging/burning sensation, dry eyes, iris and periocular hyperpigmentation, and eye lash growth, which can affect patient compliance. Preservatives used in antiglaucoma preparations can have dose-dependent toxic effects, which contribute to adverse effects. The development of preservative-free preparations may reduce such adverse effects and therefore improve patient compliance. Tafluprost is a prostaglandin analogue in a preservative-free formulation that was recently approved for the reduction of elevated IOP in open-angle glaucoma and ocular hypertension. Copyright 2010 Prous Science, S.A.U. or its licensors. All rights reserved.

  2. Evolving Knowledge in Pharmacologic Treatments of Age-Related Macular Degeneration.

    PubMed

    Soubrane Daguet, Gisèle; Risard-Gasiorowski, Sarah; Massamba, Nathalie

    2016-01-01

    Modern retinal drug therapy is a result of the recent challenges and breakthroughs in chemistry, physics, genetics, cell biology and biotechnologies. Specific pharmaceutical and pharmacokinetic characteristics of a drug are of major importance and contribute to its ability to penetrate targeted ocular tissues in order to result in effective therapeutic concentrations. In addition, the drugs should maintain a prolonged time of activity and be safe with minimal local and systemic toxicity. The transporter vehicle or drug delivery system is crucial in order to enhance ocular tissue penetration and establish controlled drug release. Administration methods should be local, thereby reducing systemic side effects, and, ideally, treatment should be noninvasive. Within the group of so-called classic therapies, the use of pharmacologic treatments has become widespread for most severe retinal diseases. Thereby, ocular therapy of diseases like exudative age-related macular degeneration has improved markedly. Moreover, new metabolic pathways have been identified, new molecules have emerged, new synthesis technologies have been discovered, and new formulae conceived. These developments have opened new avenues for limiting disease progression. © 2016 S. Karger AG, Basel.

  3. Optimizing flurbiprofen-loaded NLC by central composite factorial design for ocular delivery.

    PubMed

    Gonzalez-Mira, E; Egea, M A; Souto, E B; Calpena, A C; García, M L

    2011-01-28

    The purpose of this study was to design and optimize a new topical delivery system for ocular administration of flurbiprofen (FB), based on lipid nanoparticles. These particles, called nanostructured lipid carriers (NLC), were composed of a fatty acid (stearic acid (SA)) as the solid lipid and a mixture of Miglyol(®) 812 and castor oil (CO) as the liquid lipids, prepared by the hot high pressure homogenization method. After selecting the critical variables influencing the physicochemical characteristics of the NLC (the liquid lipid (i.e. oil) concentration with respect to the total lipid (cOil/L (wt%)), the surfactant and the flurbiprofen concentration, on particle size, polydispersity index and encapsulation efficiency), a three-factor five-level central rotatable composite design was employed to plan and perform the experiments. Morphological examination, crystallinity and stability studies were also performed to accomplish the optimization study. The results showed that increasing cOil/L (wt%) was followed by an enhanced tendency to produce smaller particles, but the liquid to solid lipid proportion should not exceed 30 wt% due to destabilization problems. Therefore, a 70:30 ratio of SA to oil (miglyol + CO) was selected to develop an optimal NLC formulation. The smaller particles obtained when increasing surfactant concentration led to the selection of 3.2 wt% of Tween(®) 80 (non-ionic surfactant). The positive effect of the increase in FB concentration on the encapsulation efficiency (EE) and its total solubilization in the lipid matrix led to the selection of 0.25 wt% of FB in the formulation. The optimal NLC showed an appropriate average size for ophthalmic administration (228.3 nm) with a narrow size distribution (0.156), negatively charged surface (-33.3 mV) and high EE (∼90%). The in vitro experiments proved that sustained release FB was achieved using NLC as drug carriers. Optimal NLC formulation did not show toxicity on ocular tissues.

  4. Optimizing flurbiprofen-loaded NLC by central composite factorial design for ocular delivery

    NASA Astrophysics Data System (ADS)

    Gonzalez-Mira, E.; Egea, M. A.; Souto, E. B.; Calpena, A. C.; García, M. L.

    2011-01-01

    The purpose of this study was to design and optimize a new topical delivery system for ocular administration of flurbiprofen (FB), based on lipid nanoparticles. These particles, called nanostructured lipid carriers (NLC), were composed of a fatty acid (stearic acid (SA)) as the solid lipid and a mixture of Miglyol® 812 and castor oil (CO) as the liquid lipids, prepared by the hot high pressure homogenization method. After selecting the critical variables influencing the physicochemical characteristics of the NLC (the liquid lipid (i.e. oil) concentration with respect to the total lipid (cOil/L (wt%)), the surfactant and the flurbiprofen concentration, on particle size, polydispersity index and encapsulation efficiency), a three-factor five-level central rotatable composite design was employed to plan and perform the experiments. Morphological examination, crystallinity and stability studies were also performed to accomplish the optimization study. The results showed that increasing cOil/L (wt%) was followed by an enhanced tendency to produce smaller particles, but the liquid to solid lipid proportion should not exceed 30 wt% due to destabilization problems. Therefore, a 70:30 ratio of SA to oil (miglyol + CO) was selected to develop an optimal NLC formulation. The smaller particles obtained when increasing surfactant concentration led to the selection of 3.2 wt% of Tween® 80 (non-ionic surfactant). The positive effect of the increase in FB concentration on the encapsulation efficiency (EE) and its total solubilization in the lipid matrix led to the selection of 0.25 wt% of FB in the formulation. The optimal NLC showed an appropriate average size for ophthalmic administration (228.3 nm) with a narrow size distribution (0.156), negatively charged surface (-33.3 mV) and high EE (~90%). The in vitro experiments proved that sustained release FB was achieved using NLC as drug carriers. Optimal NLC formulation did not show toxicity on ocular tissues.

  5. Inflammation in dry eye.

    PubMed

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  6. Multidose Preservative Free Eyedrops by Selective Removal of Benzalkonium Chloride from Ocular Formulations.

    PubMed

    Hsu, Kuan-Hui; Gupta, Karishma; Nayaka, Harish; Donthi, Aashrit; Kaul, Siddarth; Chauhan, Anuj

    2017-12-01

    About 70% of eye drops contain benzalkonium chloride (BAK) to maintain sterility. BAK is an effective preservative but it can cause irritation and toxicity. We propose to mitigate ocular toxicity without compromising sterility by incorporating a filter into an eye drop bottle to selectively remove BAK during the process of drop instillation. The filter is a packed bed of particles made from poly(2-hydroxyethyl methacrylate) (pHEMA), which is a common ophthalmic material. We showed that pHEMA particle prepared by using ethoxylated trimethylolpropane triacrylate as crosslinker can be incorporated into a modified eyedrop bottle tip to selectively remove the preservative as the formulation is squeezed out of the bottle. Hydraulic permeability of the plug is measured to determine the resistance to eye drop squeezing, and % removal of BAK and drugs are determined. The modified tip has a hydraulic permeability of about 2 Darcy, which allows eyedrops formulations to flow through without excessive resistance. The tip is designed such that the patients can create an eyedrop of solution of 1-10 cP viscosity in 4 s with a nominal pressure. During this short contact time, the packed particles removed nearly 100% of benzalkonium chloride (BAK) from a 15 mL, 0.012% BAK solution but have only minimal impact on the concentration of contained active components. Our novel design can eliminate the preservative induced toxicity from eye drops thereby impacting hundreds of millions of patients with chronic ophthalmic diseases like glaucoma and dry eyes.

  7. Simulations of simple Bovine and Homo sapiens outer cortex ocular lens membrane models with a majority concentration of cholesterol.

    PubMed

    Adams, Mark; Wang, Eric; Zhuang, Xiaohong; Klauda, Jeffery B

    2017-11-21

    The lipid composition of bovine and human ocular lens membranes has been probed, and a variety of lipids have been found including phosphatidylcholine (PC), phosphatidylethanolamine (PE), sphingomyelin (SM), and cholesterol (CHOL) with cholesterol being present in particularly high concentrations. In this study, we use the all-atom CHARMM36 force field to simulate binary, ternary, and quaternary mixtures as models of the ocular lens. High concentration of cholesterol, in combination with different and varying diversity of phospholipids (PL) and sphingolipids (SL), affect the structure of the ocular lens lipid bilayer. The following analyses were done for each simulation: surface area per lipid, component surface area per lipid, deuterium order parameters (S CD ), electron density profiles (EDP), membrane thickness, hydrogen bonding, radial distribution functions, clustering, and sterol tilt angle distribution. The S CD show significant bilayer alignment and packing in cholesterol-rich bilayers. The EDP show the transition from liquid crystalline to liquid ordered with the addition of cholesterol. Hydrogen bonds in our systems show the tendency for intramolecular interactions between cholesterol and fully saturated lipid tails for less complex bilayers. But with an increased number of components in the bilayer, the acyl chain of the lipids becomes a less important characteristic, and the headgroup of the lipid becomes more significant. Overall, cholesterol is the driving force of membrane structure of the ocular lens membrane where interactions between cholesterol, PL, and SL determine structure and function of the biomembrane. The goal of this work is to develop a baseline for further study of more physiologically realistic ocular lens lipid membranes. This article is part of a Special Issue entitled: Emergence of Complex Behavior in Biomembranes edited by Marjorie Longo. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. THE ‘HOLI’ DERMATOSES: ANNUAL SPATE OF SKIN DISEASES FOLLOWING THE SPRING FESTIVAL IN INDIA

    PubMed Central

    Ghosh, Sudip Kumar; Bandyopadhyay, Debabrata; Chatterjee, Gobinda; Saha, Debabrata

    2009-01-01

    Background: ‘Holi’ is an annual spring festival celebrated all over India. The central ritual of Holi involves throwing of colors on one another. Playing with toxic industrial dyes often results in various dermatological complaints in a significant number of people immediately following the celebration. Aims: To describe patterns of various skin manifestations directly or indirectly related to the use of different colors in the celebration of Holi. Methods: Observational clinical study on consecutive patients presenting to a teaching hospital in Kolkata, India. Results: Forty-two patients with a mean age of 24.2 years were studied. Itching was the commonest symptom (25, 59.5%), followed by burning sensation, pain, oozing, and scaling. Eleven patients’ symptoms were attributed to activities related to preparation of colors and the removal of colors from the skin surface. Eczematous lesions were the most common pattern (24, 57.1%) followed by erosions, xerosis and scaling, erythema, urticaria, acute nail-fold inflammation, and abrasions. Thirteen (30.9%) patients reported aggravation of preexisting dermatoses (acne, eczema, and paronychia). Secondary pyoderma occurred in 3 (7.1%). Face was the commonest site affected (24, 57.1%), followed by dorsum of the hands, scalp, forearm, palms, arms, and trunk. Ocular complaints in the form of redness, watering, and grittiness occurred in 7 (16.7%) patients. Conclusion: Various forms of cutaneous manifestations, often associated with ocular complaints, occur commonly due to Holi colors. Public awareness and regulatory actions are needed to avoid these preventable conditions. PMID:20161854

  9. The 'holi' dermatoses: annual spate of skin diseases following the spring festival in India.

    PubMed

    Ghosh, Sudip Kumar; Bandyopadhyay, Debabrata; Chatterjee, Gobinda; Saha, Debabrata

    2009-07-01

    'Holi' is an annual spring festival celebrated all over India. The central ritual of Holi involves throwing of colors on one another. Playing with toxic industrial dyes often results in various dermatological complaints in a significant number of people immediately following the celebration. To describe patterns of various skin manifestations directly or indirectly related to the use of different colors in the celebration of Holi. Observational clinical study on consecutive patients presenting to a teaching hospital in Kolkata, India. Forty-two patients with a mean age of 24.2 years were studied. Itching was the commonest symptom (25, 59.5%), followed by burning sensation, pain, oozing, and scaling. Eleven patients' symptoms were attributed to activities related to preparation of colors and the removal of colors from the skin surface. Eczematous lesions were the most common pattern (24, 57.1%) followed by erosions, xerosis and scaling, erythema, urticaria, acute nail-fold inflammation, and abrasions. Thirteen (30.9%) patients reported aggravation of preexisting dermatoses (acne, eczema, and paronychia). Secondary pyoderma occurred in 3 (7.1%). Face was the commonest site affected (24, 57.1%), followed by dorsum of the hands, scalp, forearm, palms, arms, and trunk. Ocular complaints in the form of redness, watering, and grittiness occurred in 7 (16.7%) patients. Various forms of cutaneous manifestations, often associated with ocular complaints, occur commonly due to Holi colors. Public awareness and regulatory actions are needed to avoid these preventable conditions.

  10. [Quaternary ammonium cytotoxicity in a human conjunctival cell line].

    PubMed

    Debbasch, C; de Saint Jean, M; Pisella, P J; Rat, P; Warnet, J M; Baudouin, C

    1999-11-01

    Ophthalmic preparations can induce conjunctival toxicity, often caused by preservatives. The aim of this study was to evaluate in vitro cytotoxicity of quaternary ammonium. Cytotoxicity tests were done on a continuous human conjunctival cell line using microplate cold light cytofluorimetry. Membrane integrity (neutral red test), DNA condensation (Hoechst 33342 test) and reactive oxygen species (ROS) production (dichlorofluorescein diacetate and hydroethidine tests) were evaluated on living cells treated with different concentrations of benzalkonium chloride, benzododecinium bromide and cetrimide (0.00001 to 0.01%) after 15 minutes of treatment or 15 minutes and 24 hours of cell recovery. All the compounds tested showed similar in vitro effects. Using the neutral red test, we observed a decrease in membrane integrity even at 0.005% and 0.01% (p < 0.001) and after a short time (15 minutes). A stimulation of ROS production (H2O2 and O2) was observed at 0.00001% and above (p < 0.001), associated with a chromatine condensation due to an apoptotic phenomenon. A necrotic phenomenon is suggested at high concentrations of quaternary ammonium preservatives whereas an apoptotic mechanism exists for lower concentrations. This toxicity observed in vitro can explain some of the ocular surface damage caused by long-term use of preserved eye-drops.

  11. An Overview of Chitosan Nanoparticles and Its Application in Non-Parenteral Drug Delivery

    PubMed Central

    Mohammed, Munawar A.; Syeda, Jaweria T. M.; Wasan, Kishor M.; Wasan, Ellen K.

    2017-01-01

    The focus of this review is to provide an overview of the chitosan based nanoparticles for various non-parenteral applications and also to put a spotlight on current research including sustained release and mucoadhesive chitosan dosage forms. Chitosan is a biodegradable, biocompatible polymer regarded as safe for human dietary use and approved for wound dressing applications. Chitosan has been used as a carrier in polymeric nanoparticles for drug delivery through various routes of administration. Chitosan has chemical functional groups that can be modified to achieve specific goals, making it a polymer with a tremendous range of potential applications. Nanoparticles (NP) prepared with chitosan and chitosan derivatives typically possess a positive surface charge and mucoadhesive properties such that can adhere to mucus membranes and release the drug payload in a sustained release manner. Chitosan-based NP have various applications in non-parenteral drug delivery for the treatment of cancer, gastrointestinal diseases, pulmonary diseases, drug delivery to the brain and ocular infections which will be exemplified in this review. Chitosan shows low toxicity both in vitro and some in vivo models. This review explores recent research on chitosan based NP for non-parenteral drug delivery, chitosan properties, modification, toxicity, pharmacokinetics and preclinical studies. PMID:29156634

  12. Assessment of surface concentrations in resorbable ocular implants: controlled drug delivery devices for 5-fluorouracil (5-FU)

    NASA Astrophysics Data System (ADS)

    Milne, Peter J.; Gautier, Sandrine; Parel, Jean-Marie A.; Jallet, Valerie

    1997-05-01

    The antineoplastic drug 5-fluorouracil (5-fluoro- 2,4,(1H,3H)-pyrimidinedione; 5-FU) has been used to control proliferation of penetrating fibroblasts and to prevent channel closure following glaucoma filtration surgery (trabeculectomy) or laser sclerectomy. Because of the toxicity of the drug, administration of low dosages slowly over time, at the site of the desired treatment, is indicated for optimum efficacy. Repeated injections of low dosages of the drug represent an undesirable intervention and may also result in unwanted toxicity to the corneal epithelium. A suitable biocompatible and resorbable polymer matrix composed of a poly (D,L-lactic-co-glycolic acid: PLGA) has been admixed with varying amounts of 5-FU and cast as shapes suitable for intracorneal implantation. Slow biodegradation of this polymer over a one to two week period has been shown to result in an acceptably slow drug release mechanism. An issue arising during the clinical evaluation of the efficacy of this drug delivery system was how best to quantify the concentration of 5-FU and its distribution spatially in the solid implant. FT-IR and FT-Raman spectroscopies distinguishes between the drug and the polymer matrix and were used to differentiate and quantitate the 5-FU concentration of the implants.

  13. Correlation of Superior Canal Dehiscence Surface Area With Vestibular Evoked Myogenic Potentials, Audiometric Thresholds, and Dizziness Handicap.

    PubMed

    Hunter, Jacob B; O'Connell, Brendan P; Wang, Jianing; Chakravorti, Srijata; Makowiec, Katie; Carlson, Matthew L; Dawant, Benoit; McCaslin, Devin L; Noble, Jack H; Wanna, George B

    2016-09-01

    To correlate objective measures of vestibular and audiometric function as well as subjective measures of dizziness handicap with the surface area of the superior canal dehiscence (SCD). Retrospective chart review and radiological analysis. Single tertiary academic referral center. Preoperative computed tomography imaging, patient survey, audiometric thresholds, and vestibular evoked myogenic potential (VEMP) testing in patients with confirmed SCD. Image analysis techniques were developed to measure the surface area of each SCD in computed tomography imaging. Preoperative ocular and cervical VEMPs, air and bone conduction thresholds, air-bone gap, dizziness handicap inventory scores, and surface area of the SCD. Fifty-three patients (mean age 52.7 yr) with 84 SCD were analyzed. The median surface area of dehiscence was 1.44 mm (0.068-8.23 mm). Ocular VEMP amplitudes (r = 0.61, p <0.0001), cervical VEMP amplitudes (r = 0.62, p <0.0001), air conduction thresholds at 250 Hz (r = 0.25, p = 0.043), and air-bone gap at 500 Hz (r = 0.27, p = 0.01) positively correlated with increasing size of dehiscence. An inverse relationship between cervical VEMP thresholds (r = -0.56, p < 0.0001) and surface area of the dehiscence was observed. No association between dizziness handicap and surface area was identified. Among patients with confirmed SCD, ocular and cervical VEMP amplitudes, cervical VEMP thresholds, and air conduction thresholds at 250 Hz are significantly correlated with the surface area of the dehiscence.

  14. TFOS DEWS II Definition and Classification Report.

    PubMed

    Craig, Jennifer P; Nichols, Kelly K; Akpek, Esen K; Caffery, Barbara; Dua, Harminder S; Joo, Choun-Ki; Liu, Zuguo; Nelson, J Daniel; Nichols, Jason J; Tsubota, Kazuo; Stapleton, Fiona

    2017-07-01

    The goals of the TFOS DEWS II Definition and Classification Subcommittee were to create an evidence-based definition and a contemporary classification system for dry eye disease (DED). The new definition recognizes the multifactorial nature of dry eye as a disease where loss of homeostasis of the tear film is the central pathophysiological concept. Ocular symptoms, as a broader term that encompasses reports of discomfort or visual disturbance, feature in the definition and the key etiologies of tear film instability, hyperosmolarity, and ocular surface inflammation and damage were determined to be important for inclusion in the definition. In the light of new data, neurosensory abnormalities were also included in the definition for the first time. In the classification of DED, recent evidence supports a scheme based on the pathophysiology where aqueous deficient and evaporative dry eye exist as a continuum, such that elements of each are considered in diagnosis and management. Central to the scheme is a positive diagnosis of DED with signs and symptoms, and this is directed towards management to restore homeostasis. The scheme also allows consideration of various related manifestations, such as non-obvious disease involving ocular surface signs without related symptoms, including neurotrophic conditions where dysfunctional sensation exists, and cases where symptoms exist without demonstrable ocular surface signs, including neuropathic pain. This approach is not intended to override clinical assessment and judgment but should prove helpful in guiding clinical management and research. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Diagnosis of X-Linked Hypohidrotic Ectodermal Dysplasia by Meibography and Infrared Thermography of the Eye.

    PubMed

    Kaercher, Thomas; Dietz, Jasna; Jacobi, Christina; Berz, Reinhold; Schneider, Holm

    2015-09-01

    X-linked hypohidrotic ectodermal dysplasia (XLHED) is the most common form of ectodermal dysplasia. Clinical characteristics include meibomian gland disorder and the resulting hyperevaporative dry eye. In this study, we evaluated meibography and ocular infrared thermography as novel methods to diagnose XLHED. Eight infants, 12 boys and 14 male adults with XLHED and 12 healthy control subjects were subjected to a panel of tests including the ocular surface disease index (OSDI), meibography and infrared thermography, non-invasive measurement of tear film break-up time (NIBUT) and osmolarity, Schirmer's test, lissamine green staining and fluorescein staining. Sensitivity and specificity were determined for single tests and selected test combinations. Meibography had 100% sensitivity and specificity for identifying XLHED. Infrared thermography, a completely non-invasive procedure, revealed a typical pattern for male subjects with XLHED. It was, however, less sensitive (86% for adults and 67% for children) than meibography or a combination of established routine tests. In adults, OSDI and NIBUT were the best single routine tests (sensitivity of 86% and 71%, respectively), whereas increased tear osmolarity appeared as a rather unspecific ophthalmic symptom. In children, NIBUT was the most convincing routine test (sensitivity of 91%). Meibography is the most reliable ophthalmic examination to establish a clinical diagnosis in individuals with suspected hypohidrotic ectodermal dysplasia, even before genetic test results are available. Tear film tests and ocular surface staining are less sensitive in children, but very helpful for estimating the severity of ocular surface disease in individuals with known XLHED.

  16. Cicatricial changes in ocular pemphigus

    PubMed Central

    Chirinos-Saldaña, P; Zuñiga-Gonzalez, I; Hernandez-Camarena, J C; Navas, A; Ramirez-Luquin, T; Robles-Contreras, A; Jimenez-Martinez, M C; Ramirez-Miranda, A; Bautista-de Lucio, V M; Graue-Hernandez, E O

    2014-01-01

    Purpose To describe the clinical characteristics of ocular involvement in patients with pemphigus at an ophthalmological referral center. Methods A retrospective review was conducted on patients with the immunopathological diagnosis of pemphigus examined between 1 January 2000 and 1 April 2010. Uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (BCVA), ocular symptoms, and ocular surface inflammatory and scarring changes were assessed. Results A total of 15 patients were identified, with a mean age of 68.27±14.35 years, and 80% (n=12) were female. Extraocular involvement was reported in one patient. All of the eyes showed cicatricial changes in the conjunctiva. In all, 6 eyes (20%) were classified as stage I; 12 eyes (40%) as stage II; 10 eyes (33%) as stage III; and 2 eyes (7%) as stage IV. A statistically significant association was found between BCVA and the severity of ocular involvement. The mean BCVA logMAR was 1.66 (20/914), with a range from logMAR 0 (20/20) to logMAR 4 (NLP). Other ocular diseases were found in 8 (53.3%), systemic diseases in 10 (66.7%), and the use of pemphigus-inducing drugs in 10 patients (66.7%). Conclusions The present report represents the largest series of ocular involvement in pemphigus confirmed by immunopathology. The clinical manifestations varied from conjunctival hyperemia to corneal scarring and perforation. There was a strong association between scarring changes and low BCVA. Ocular and systemic diseases as well as the use of pemphigus-inducing drugs may predispose to ocular cicatricial changes observed in this series. PMID:24480839

  17. Spontaneous Blinking from a Tribological Viewpoint.

    PubMed

    Pult, Heiko; Tosatti, Samuele G P; Spencer, Nicholas D; Asfour, Jean-Michel; Ebenhoch, Michael; Murphy, Paul J

    2015-07-01

    The mechanical forces between the lid wiper and the ocular surface, and between a contact lens and the lid wiper, are reported to be related to dry eye symptoms. Furthermore, the mechanical forces between these sliding partners are assumed to be related to the ocular signs of lid-wiper epitheliopathy (LWE) and lid-parallel conjunctival folds (LIPCOF). Recent literature provides some evidence that a contact lens with a low coefficient of friction (CoF) improves wearing comfort by reducing the mechanical forces between the contact lens surface and the lid wiper. This review discusses the mechanical forces during spontaneous blinks from a tribological perspective, at both low and high sliding velocities, in a healthy subject. It concludes that the coefficient of friction of the ocular surfaces appears to be strongly comparable to that of hydrophilic polymer brushes at low sliding velocity, and that, with increased sliding velocity, there is no wear at the sliding partners' surfaces thanks to the presence of a fluid film between the two sliding partners. In contrast, in the case of dry eye, the failure to maintain a full fluid film lubrication regime at high blinking speeds may lead to increased shear rates, resulting in deformation and wear of the sliding pairs. These shear rates are most likely related to tear film viscosity. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Microbial contamination of contact lenses, lens care solutions, and their accessories: a literature review.

    PubMed

    Szczotka-Flynn, Loretta B; Pearlman, Eric; Ghannoum, Mahmoud

    2010-03-01

    A contact lens (CL) can act as a vector for microorganisms to adhere to and transfer to the ocular surface. Commensal microorganisms that uneventfully cohabitate on lid margins and conjunctivae and potential pathogens that are found transiently on the ocular surface can inoculate CLs in vivo. In the presence of reduced tissue resistance, these resident microorganisms or transient pathogens can invade and colonize the cornea or conjunctiva to produce inflammation or infection. The literature was reviewed and used to summarize the findings over the last 30 years on the identification, enumeration, and classification of microorganisms adherent to CLs and their accessories during the course of normal wear and to hypothesize the role that these microorganisms play in CL infection and inflammation. Lens handling greatly increases the incidence of lens contamination, and the ocular surface has a tremendous ability to destroy organisms. However, even when removed aseptically from the eye, more than half of lenses are found to harbor microorganisms, almost exclusively bacteria. Coagulase-negative Staphylococci are most commonly cultured from worn lenses; however, approximately 10% of lenses harbor Gram-negative and highly pathogenic species, even in asymptomatic subjects. In storage cases, the incidence of positive microbial bioburden is also typically greater than 50%. All types of care solutions can become contaminated, including up to 30% of preserved products. The process of CL-related microbial keratitis and inflammation is thought to be preceded by the presence or transfer or both of microorganisms from the lens to the ocular surface. Thus, this detailed understanding of lens-related bioburden is important in the understanding of factors associated with infectious and inflammatory complications. Promising mechanisms to prevent bacterial colonization on lenses and lens cases are forthcoming, which may decrease the incidence of microbially driven CL complications.

  19. Effect of Omega-3 Fatty Acids Dietary Supplementation on Ocular Surface and Tear Film in Diabetic Patients with Dry Eye.

    PubMed

    Georgakopoulos, Constantine D; Makri, Olga E; Pagoulatos, Dionisios; Vasilakis, Panagiotis; Peristeropoulou, Politimi; Kouli, Vasiliki; Eliopoulou, Maria I; Psachoulia, Caterina

    2017-01-01

    The objective of this study was to investigate the effect of dietary supplementation with omega-3 fatty acids on ocular surface and tear film in patients with type 2 diabetes suffering from dry eye. Thirty-six patients suffering from type 2 diabetes and moderate to severe dry eye syndrome were included in the study. Patients were assigned to receive omega-3 long-chain polyunsaturated fatty acids for 3 months. Tear film break-up time test, Schirmer-I test, and conjunctival impression cytology analysis were performed on all patients at baseline and after 1 and 3 months. The subjective symptoms of dry eye were evaluated with the Ocular Surface Disease Index (OSDI) questionnaire at the same time points. Patients' average age was 65.57 ± 4.27 years and the mean duration of diabetes was 14.85 ± 5.4 years. There was a statistically significant increase in Schirmer-I test results and tear break-up time score after 3 months of supplementary intake of omega-3 fatty acids compared to baseline (p < 0.05 and p < 0.001, respectively). Impression cytology demonstrated a significantly lower grade of conjunctival squamous cell metaplasia after 1 and 3 months of omega-3 fatty acids intake compared to baseline (p < 0.05 and p < 0.01, respectively). The OSDI score was statistically significant lower both at 1 and 3 months after omega-3 fatty acids supplementation compared to baseline (p < 0.001). Omega-3 fatty acids may effectively improve tear film characteristics, reverse ocular surface features, and alleviate the subjective symptoms associated with dry eye syndrome in patients with type 2 diabetes.

  20. Effects of Menthol-Containing Artificial Tears on Tear Stimulation and Ocular Surface Integrity in Normal and Dry Eye Rat Models.

    PubMed

    Ahn, Somin; Eom, Youngsub; Kang, Boram; Park, Jungboung; Lee, Hyung Keun; Kim, Hyo Myung; Song, Jong Suk

    2018-05-01

    To evaluate the effects of menthol-containing artificial tears on tear stimulation and ocular surface integrity in normal and dry eye rat models. A total of 54 male Lewis rats were used. The levels of tear secretion and tear MUC5AC concentrations were compared between the menthol-containing artificial tear-treated group (menthol group) and the vehicle-treated group (vehicle group). The groups were compared after a single instillation to evaluate the immediate effects, and after repeated instillation (five times a day for 5 days) to evaluate the longer-term effects. Tear lactate dehydrogenase (LDH) activity was measured to evaluate eye drop instillation-induced ocular surface damage. The effects of menthol-containing artificial tears were also evaluated in a dry eye rat model. After a single instillation of menthol-containing artificial tears, tear secretion increased from 4.37 (±0.75) mm at baseline to 7.37 (±1.60) mm. However, after repeated instillations, the effects of tear stimulation decreased. The tear MUC5AC concentration was significantly lower in the menthol group than in the vehicle group after a single instillation, but not after repeated instillation. However, the tear LDH concentration was significantly increased in the menthol group after repeated instillation. In the dry eye rat model, the extent of menthol-induced tear stimulation was reduced. Menthol-containing artificial tears increased tear secretion, but lowered the tear MUC5AC concentration. Menthol-induced tear stimulation was reduced after repeated instillation for 5 days and in the dry eye rat model. Conversely, repeated instillation of menthol-induced ocular surface damage, resulting in increased tear LDH activity.

  1. Regional differences in rat conjunctival ion transport activities

    PubMed Central

    Yu, Dongfang; Thelin, William R.; Rogers, Troy D.; Stutts, M. Jackson; Randell, Scott H.; Grubb, Barbara R.

    2012-01-01

    Active ion transport and coupled osmotic water flow are essential to maintain ocular surface health. We investigated regional differences in the ion transport activities of the rat conjunctivas and compared these activities with those of cornea and lacrimal gland. The epithelial sodium channel (ENaC), sodium/glucose cotransporter 1 (Slc5a1), transmembrane protein 16 (Tmem16a, b, f, and g), cystic fibrosis transmembrane conductance regulator (Cftr), and mucin (Muc4, 5ac, and 5b) mRNA expression was characterized by RT-PCR. ENaC proteins were measured by Western blot. Prespecified regions (palpebral, fornical, and bulbar) of freshly isolated conjunctival tissues and cell cultures were studied electrophysiologically with Ussing chambers. The transepithelial electrical potential difference (PD) of the ocular surface was also measured in vivo. The effect of amiloride and UTP on the tear volume was evaluated in lacrimal gland excised rats. All selected genes were detected but with different expression patterns. We detected αENaC protein in all tissues, βENaC in palpebral and fornical conjunctiva, and γENaC in all tissues except lacrimal glands. Electrophysiological studies of conjunctival tissues and cell cultures identified functional ENaC, SLC5A1, CFTR, and TMEM16. Fornical conjunctiva exhibited the most active ion transport under basal conditions amongst conjunctival regions. PD measurements confirmed functional ENaC-mediated Na+ transport on the ocular surface. Amiloride and UTP increased tear volume in lacrimal gland excised rats. This study demonstrated that the different regions of the conjunctiva exhibited a spectrum of ion transport activities. Understanding the specific functions of distinct regions of the conjunctiva may foster a better understanding of the physiology maintaining hydration of the ocular surface. PMID:22814399

  2. Effects of silicone hydrogel contact lenses on ocular surface after Sub-Bowman's Keratomileusis.

    PubMed

    Gao, Shaohui; Wu, Junshu; Li, Lili; Wang, Yong; Zhong, Xingwu

    2013-11-01

    To evaluate the efficacy of silicone hydrogel contact lenses on ocular surface after Sub-Bowman Keratomileusis (SBK). Forty-six patients suffered from myopia underwent a bilateral SBK. Post-operatively, one eye of each patient wore a PureVision contact lens for 24 h as a treated eye and the contralateral eye was as a blank control. Afterwards, corneal fluorescein (FL) staining, tear break-up time (TBUT), schirmer I test (SIT), central corneal thickness (CCT), ocular surface disease index (OSDI), corneal hysteresis (CH), corneal resistance factor (CRF) and corneal flap complications were assessed 1 d (except for CH and CRF), 1 week, 1 month and 3 months postoperatively. Following SBK, in contrast to the control, corneal fluorescein staining of treated eyes were significantly reduced and tear break-up time of treated eyes were significantly improved at 1 d and 1 week after SBK. However, Schirmer I test of treated and control eyes were not different after SBK. Central corneal thickness of treated eyes were significantly thinner than that of control at 1 d after SBK, however, there were no differences at other time points. Ocular surface disease index of treated eyes were obviously alleviated more than that of control at 1 d after SBK, but no differences were found at other visits. Moreover, Corneal hysteresis and corneal resistance factor of treated and un-treated eyes were not different after surgery. And also the rate of corneal flap complications were not different between treated and control eyes after SBK. Silicone hydrogel contact lenses played a positive role in accelerating corneal epithelial healing, enhancing tear film stability and reducing discomfort of patients in the early stage after SBK.

  3. The relation of functional visual acuity measurement methodology to tear functions and ocular surface status.

    PubMed

    Kaido, Minako; Ishida, Reiko; Dogru, Murat; Tsubota, Kazuo

    2011-09-01

    To investigate the relation of functional visual acuity (FVA) measurements with dry eye test parameters and to compare the testing methods with and without blink suppression and anesthetic instillation. A prospective comparative case series. Thirty right eyes of 30 dry eye patients and 25 right eyes of 25 normal subjects seen at Keio University School of Medicine, Department of Ophthalmology were studied. FVA testing was performed using a FVA measurement system with two different approaches, one in which measurements were made under natural blinking conditions without topical anesthesia (FVA-N) and the other in which the measurements were made under the blink suppression condition with topical anesthetic eye drops (FVA-BS). Tear function examinations, such as the Schirmer test, tear film break-up time, and fluorescein and Rose Bengal vital staining as ocular surface evaluation, were performed. The mean logMAR FVA-N scores and logMAR Landolt visual acuity scores were significantly lower in the dry eye subjects than in the healthy controls (p < 0.05), while there were no statistical differences between the logMAR FVA-BS scores of the dry eye subjects and those of the healthy controls. There was a significant correlation between the logMAR Landolt visual acuities and the logMAR FVA-N and logMAR FVA-BS scores. The FVA-N scores correlated significantly with tear quantities, tear stability and, especially, the ocular surface vital staining scores. FVA measurements performed under natural blinking significantly reflected the tear functions and ocular surface status of the eye and would appear to be a reliable method of FVA testing. FVA measurement is also an accurate predictor of dry eye status.

  4. Cytokine and chemokine levels in tears from healthy subjects.

    PubMed

    Carreño, Ester; Enríquez-de-Salamanca, Amalia; Tesón, Marisa; García-Vázquez, Carmen; Stern, Michael E; Whitcup, Scott M; Calonge, Margarita

    2010-11-01

    There is growing evidence for the existence of an 'immune tone' in normal tears. The aim of this study was to determine the levels of a large panel of cytokines and chemokines in tears obtained from healthy subjects. These levels can then serve as baseline values for comparison with patients suffering from ocular surface diseases. Nine healthy subjects participated in this study, and normal ocular surface health was documented by the results of a dry eye questionnaire, Schirmer strip wetting, and vital staining of the cornea. Four microliters of tears were collected from each eye and analysed separately with multiplex bead-based assays for the concentration of 30 cytokines and chemokines. Twenty-five cytokines/chemokines were detected. CCL11/Eotaxin1, GM-CSF, G-CSF, IFN-γ, IL-2, IL-3, IL-4, IL-5, IL-10, IL-13, IL-12p70, IL-15, CX3CL1/Fractalkine, TNF-α, epidermal growth factor, and CCL4/MIP-1β were present at 5-100 pg/ml. IL-1β, IL-6, IL-7A, CXCL8/IL-8, and CCL2/MCP-1 were present at 100-400 pg/ml. IL-1Ra, CXCL10/IP-10 and vascular endothelial growth factor were present at more than 1000 pg/ml. Multiplex bead-based assays are convenient for cytokine/chemokine detection in tears. Fracktalkine has been detected in human healthy tears for the first time. The knowledge of cytokine/chemokine concentrations in tears from normal subjects is an important reference for further comparison with patients suffering from ocular surface diseases. Variability in their levels can reflect a phenomenon of potential importance for the understanding of the ocular surface cytokine pattern. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  5. Influence of femtosecond lenticule extraction and small incision lenticule extraction on corneal nerve density and ocular surface: a 1-year prospective, confocal, microscopic study.

    PubMed

    Ishii, Rie; Shimizu, Kimiya; Igarashi, Akihito; Kobashi, Hidenaga; Kamiya, Kazutaka

    2015-01-01

    To compare the influence of femtosecond lenticule extraction (FLEx) and small incision lenticule extraction (SMILE) on corneal nerve density and the ocular surface for equivalent degrees of correction of myopia. Sixty eyes of 30 patients (8 males and 22 females, mean age: 31.0 ± 6.0 years) were included in the study. The patients underwent FLEx in 1 eye and SMILE in the other eye by random assignment. Subbasal nerve density was measured using confocal microscopy preoperatively and at 1 week, 1 and 3 months, and 1 year postoperatively. Ocular surface parameters such as Schirmer's test results, tear film break-up time, and corneal sensation were performed preoperatively and at 1 and 3 months postoperatively. In the FLEx group, subbasal nerve density was 18,390 ± 6,090 µm/mm(2) preoperatively and 5,770 ± 3,490 µm/mm(2) at 1 year postoperatively (P < .001, Dunnett's test). In the SMILE group, subbasal nerve density was 16,810 ± 6,220 µm/mm(2) preoperatively and 11,870 ± 8,200 µm/mm(2) at 1 year postoperatively (P = .21). The decrease in corneal nerve density was significantly less after SMILE than after FLEx at all postoperative visits (Mann-Whitney U test, P < .05). FLEx resulted in a significant decrease in Schirmer's test results, tear film break-up time, and corneal sensation at all postoperative visits, whereas SMILE induced no significant changes in these parameters (P > .05). There was less damage to the sub-basal nerve plexus of the cornea and less effect on the ocular surface parameters after SMILE than after FLEx. Copyright 2015, SLACK Incorporated.

  6. Regional differences in rat conjunctival ion transport activities.

    PubMed

    Yu, Dongfang; Thelin, William R; Rogers, Troy D; Stutts, M Jackson; Randell, Scott H; Grubb, Barbara R; Boucher, Richard C

    2012-10-01

    Active ion transport and coupled osmotic water flow are essential to maintain ocular surface health. We investigated regional differences in the ion transport activities of the rat conjunctivas and compared these activities with those of cornea and lacrimal gland. The epithelial sodium channel (ENaC), sodium/glucose cotransporter 1 (Slc5a1), transmembrane protein 16 (Tmem16a, b, f, and g), cystic fibrosis transmembrane conductance regulator (Cftr), and mucin (Muc4, 5ac, and 5b) mRNA expression was characterized by RT-PCR. ENaC proteins were measured by Western blot. Prespecified regions (palpebral, fornical, and bulbar) of freshly isolated conjunctival tissues and cell cultures were studied electrophysiologically with Ussing chambers. The transepithelial electrical potential difference (PD) of the ocular surface was also measured in vivo. The effect of amiloride and UTP on the tear volume was evaluated in lacrimal gland excised rats. All selected genes were detected but with different expression patterns. We detected αENaC protein in all tissues, βENaC in palpebral and fornical conjunctiva, and γENaC in all tissues except lacrimal glands. Electrophysiological studies of conjunctival tissues and cell cultures identified functional ENaC, SLC5A1, CFTR, and TMEM16. Fornical conjunctiva exhibited the most active ion transport under basal conditions amongst conjunctival regions. PD measurements confirmed functional ENaC-mediated Na(+) transport on the ocular surface. Amiloride and UTP increased tear volume in lacrimal gland excised rats. This study demonstrated that the different regions of the conjunctiva exhibited a spectrum of ion transport activities. Understanding the specific functions of distinct regions of the conjunctiva may foster a better understanding of the physiology maintaining hydration of the ocular surface.

  7. Improvements in Topical Ocular Drug Delivery Systems: Hydrogels and Contact Lenses.

    PubMed

    Ribeiro, Andreza Maria; Figueiras, Ana; Veiga, Francisco

    2015-01-01

    Conventional ophthalmic systems present very low corneal systemic bioavailability due to the nasolacrimal drainage and the difficulty to deliver the drug in the posterior segment of ocular tissue. For these reasons, recent advances have focused on the development of new ophthalmic drug delivery systems. This review provides an insight into the various constraints associated with ocular drug delivery, summarizes recent findings in soft contact lenses (SCL) and the applications of novel pharmaceutical systems for ocular drug delivery. Among the new therapeutic approaches in ophthalmology, SCL are novel continuous-delivery systems, providing high and sustained levels of drugs to the cornea. The tendency of research in ophthalmic drug delivery systems development are directed towards a combination of several technologies (bio-inspired and molecular imprinting techniques) and materials (cyclodextrins, surfactants, specific monomers). There is a tendency to develop systems which not only prolong the contact time of the vehicle at the ocular surface, but also at the same time slow down the clearance of the drug. Different materials can be applied during the development of contact lenses and can be combined with natural inspired strategies of drug immobilization and release, providing successful tools for ocular drug delivery systems.

  8. Poly(ortho ester) nanoparticles targeted for chronic intraocular diseases: ocular safety and localization after intravitreal injection.

    PubMed

    Li, Huiling; Palamoor, Mallika; Jablonski, Monica M

    2016-10-01

    Treatment of posterior eye diseases is more challenging than the anterior segment ailments due to a series of anatomical barriers and physiological constraints confronted by drug delivery to the back of the eye. In recent years, concerted efforts in drug delivery have been made to prolong the residence time of drugs injected in the vitreous humor of the eye. Our previous studies demonstrated that poly(ortho ester) (POE) nanoparticles were biodegradable/biocompatible and were capable of long-term sustained release. The objective of the present study was to investigate the safety and localization of POE nanoparticles in New Zealand white rabbits and C57BL/6 mice after intravitreal administration for the treatment of chronic posterior ocular diseases. Two concentration levels of POE nanoparticles solution were chosen for intravitreal injection: 1.5 mg/ml and 10 mg/ml. Our results demonstrate that POE nanoparticles were distributed throughout the vitreous cavity by optical coherence tomography (OCT) examination 14 days post-intravitreal injection. Intraocular pressure was not changed from baseline. Inflammatory or adverse effects were undetectable by slit lamp biomicroscopy. Furthermore, we demonstrate that POE nanoparticles have negligible toxicity assessed at the cellular level evidenced by a lack of glia activation or apoptosis estimation after intravitreal injection. Collectively, POE nanoparticles are a novel and nontoxic as an ocular drug delivery system for the treatment of posterior ocular diseases.

  9. Dry Eye: an Inflammatory Ocular Disease

    PubMed Central

    Hessen, Michelle; Akpek, Esen Karamursel

    2014-01-01

    Keratoconjunctivitis sicca, or dry eye, is a common ocular disease prompting millions of individuals to seek ophthalmological care. Regardless of the underlying etiology, dry eye has been shown to be associated with abnormalities in the pre-corneal tear film and subsequent inflammatory changes in the entire ocular surface including the adnexa, conjunctiva and cornea. Since the recognition of the role of inflammation in dry eye, a number of novel treatments have been investigated designed to inhibit various inflammatory pathways. Current medications that are used, including cyclosporine A, corticosteroids, tacrolimus, tetracycline derivatives and autologous serum, have been effective for management of dry eye and lead to measurable clinical improvement. PMID:25279127

  10. Nonclinical Safety Assessment of Anti-Factor D: Key Strategies and Challenges for the Nonclinical Development of Intravitreal Biologics.

    PubMed

    Bantseev, Vladimir; Erickson, Rebecca; Leipold, Douglas; Amaya, Caroline; Miller, Paul E; Booler, Helen; Thackaberry, Evan A

    The nonclinical toxicology program described here was designed to characterize the safety profile of anti-factor D (AFD; FCFD4514S, lampalizumab) to support intravitreal (ITV) administration in patients with geographic atrophy (GA). The toxicity of AFD was assessed in a single-dose and 6-month repeat-dose study in monkeys at doses up to 10 mg/eye. Toxicity was assessed by clinical ophthalmic examinations, intraocular pressure measurements, ocular photography, electroretinography, fluorescein angiography, optical coherence tomography, and anatomic pathology. Systemic exposure to AFD generally increased with the increase in dose level. The increases in mean maximal concentration and area under the curve values were roughly dose proportional. No accumulation of AFD was observed following 10 doses, and drug exposures were not affected by anti-drug antibodies. AFD was locally and systemically well tolerated in monkeys following ITV doses of up to 10 mg/eye. Ocular effects associated with AFD were limited to transient, reversible, dose-related, aqueous cell responses and injection-related, mild, vitreal cell responses. In the 6-month repeat-dose study, 2 monkeys had a nonspecific immune response to AFD that resulted in severe ocular inflammation, attributed to administration of a heterologous (humanized) protein. The comprehensive toxicology program in monkeys described here was designed to evaluate the safety profile of AFD and to support multiple ITV injections in the clinic. Administration of a heterologous (humanized) protein presents a challenge, and immunogenicity in nonclinical species is not predictive of immunogenicity in humans. Taken together, the results of the nonclinical program described here support the use of AFD in patients with GA.

  11. Evaluation of an Injectable Thermosensitive Hydrogel As Drug Delivery Implant for Ocular Glaucoma Surgery

    PubMed Central

    Zhao, Feng; Zheng, Qiongjuan; Li, Xiaoning; Luo, Jing; Liu, Ji; Quan, Daping; Ge, Jian

    2014-01-01

    In this study, a biodegradable thermo-sensitive hydrogel from poly(trimethylene carbonate)15-F127-poly(trimethylene carbonate)15 (PTMC15-F127-PTMC15) was designed and evaluated as an injectable implant during ocular glaucoma filtration surgery in vivo and in vitro. Mitomycin C (MMC) was loaded into this hydrogel for controlled released to prolong the efficacy and to reduce the long-term toxicity. The properties of the hydrogel were confirmed using 1H NMR and gel permeation chromatography (GPC). Compared to the Pluronic F127 hydrogel, the PTMC15-F127-PTMC15 hydrogel showed a good solution-gel transition temperature at 37°C, a lower work concentration of 5% w/v and a longer mass loss time of more than 2 weeks. The in vitro study showed that the drug could be released from PTMC15-F127-PTMC15 (5% w/v) hydrogel for up to 16 days with only 57% of drug released in the first day. Moreover, the cell toxicity, which was tested via LDH and ANNEXIN V/PI, decreased within 72 h in human tenon's fibroblast cells (HTFs). The in vivo behavior in a rabbit glaucoma filtration surgery model indicated that this hydrogel loaded with 0.1 mg/ml MMC led to a better functional bleb with a prolonged mean bleb survival time (25.5±2.9 days). The scar tissue formation, new collagen deposition and myofibroblast generation appeared to be reduced upon histological and immunohistochemistry examinations, with no obvious side effects and inflammatory reactions. The in vitro and in vivo results demonstrated that this novel hydrogel is a safe and effective drug delivery candidate in ocular glaucoma surgery. PMID:24950176

  12. Evaluation of an injectable thermosensitive hydrogel as drug delivery implant for ocular glaucoma surgery.

    PubMed

    Xi, Lei; Wang, Tao; Zhao, Feng; Zheng, Qiongjuan; Li, Xiaoning; Luo, Jing; Liu, Ji; Quan, Daping; Ge, Jian

    2014-01-01

    In this study, a biodegradable thermo-sensitive hydrogel from poly(trimethylene carbonate)15-F127-poly(trimethylene carbonate)15 (PTMC15-F127-PTMC15) was designed and evaluated as an injectable implant during ocular glaucoma filtration surgery in vivo and in vitro. Mitomycin C (MMC) was loaded into this hydrogel for controlled released to prolong the efficacy and to reduce the long-term toxicity. The properties of the hydrogel were confirmed using 1H NMR and gel permeation chromatography (GPC). Compared to the Pluronic F127 hydrogel, the PTMC15-F127-PTMC15 hydrogel showed a good solution-gel transition temperature at 37°C, a lower work concentration of 5% w/v and a longer mass loss time of more than 2 weeks. The in vitro study showed that the drug could be released from PTMC15-F127-PTMC15 (5% w/v) hydrogel for up to 16 days with only 57% of drug released in the first day. Moreover, the cell toxicity, which was tested via LDH and ANNEXIN V/PI, decreased within 72 h in human tenon's fibroblast cells (HTFs). The in vivo behavior in a rabbit glaucoma filtration surgery model indicated that this hydrogel loaded with 0.1 mg/ml MMC led to a better functional bleb with a prolonged mean bleb survival time (25.5±2.9 days). The scar tissue formation, new collagen deposition and myofibroblast generation appeared to be reduced upon histological and immunohistochemistry examinations, with no obvious side effects and inflammatory reactions. The in vitro and in vivo results demonstrated that this novel hydrogel is a safe and effective drug delivery candidate in ocular glaucoma surgery.

  13. Development of ocular drug delivery systems using molecularly imprinted soft contact lenses.

    PubMed

    Tashakori-Sabzevar, Faezeh; Mohajeri, Seyed Ahmad

    2015-05-01

    Recently, significant advances have been made in order to optimize drug delivery to ocular tissues. The main problems in ocular drug delivery are poor bioavailability and uncontrollable drug delivery of conventional ophthalmic preparations (e.g. eye drops). Hydrogels have been investigated since 1965 as new ocular drug delivery systems. Increase of hydrogel loading capacity, optimization of drug residence time on the ocular surface and biocompatibility with the eye tissue has been the main focus of previous studies. Molecular imprinting technology provided the opportunity to fulfill the above-mentioned objectives. Molecularly imprinted soft contact lenses (SCLs) have high potentials as novel drug delivery systems for the treatment of eye disorders. This technique is used for the preparation of polymers with specific binding sites for a template molecule. Previous studies indicated that molecular imprinting technology could be successfully applied for the preparation of SCLs as ocular drug delivery systems. Previous research, particularly in vivo studies, demonstrated that molecular imprinting is a versatile and effective method in optimizing the drug release behavior and enhancing the loading capacity of SCLs as new ocular drug delivery systems. This review highlights various potentials of molecularly imprinted contact lenses in enhancing the drug-loading capacity and controlling the drug release, compared to other ocular drug delivery systems. We have also studied the effects of contributing factors such as the type of comonomer, template/functional monomer molar ratio, crosslinker concentration in drug-loading capacity, and the release properties of molecularly imprinted hydrogels.

  14. Nanoparticle Delivery Of RNAi Therapeutics For Ocular Vesicant Injury

    DTIC Science & Technology

    2014-12-01

    micellar nanoparticles stabilized with disulfide crosslinking, hypothesizing that PEG corona on micellar nanoparticles could reduce toxicity while...micelles. This is analogous to micelle assembly, where the shape control is governed by the volume ratio of the hydrophilic ( corona ) to...self-assembly of the complexes between siRNA and LPEI-g-PEG copolymer carriers. The PEG corona and reversibly crosslinked core of the micelles enable

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roman, Danielle, E-mail: danielle.roman@novartis.c

    AUY922, a heat shock protein 90 inhibitor is associated with ocular adverse events (AEs). To provide a better understanding of ocular AEs in patients, 4 investigative studies were performed in a step-wise approach to assess retinal structure and function in pigmented (Brown Norway) and albino (Wistar) rats. In rats administered 30 mg/kg of AUY922, the AUC{sub 0–24} {sub h} and C{sub max} are comparable to that in patients at 70 mg/m{sup 2}. AUY922 at ≥ 30 mg/kg was poorly tolerated by rats with morbidity or mortality generally after the third weekly treatment. Electroretinography (ERG) changes were observed at doses ≥more » 30 mg/kg. The ERG changes were dose dependent, consistent with an effect on the photoreceptors, and fully reversible. The ERG effects could not be minimized by decreasing the C{sub max} while maintaining AUC. Histopathological changes were seen mainly when rats were administered AUY922 at 100 mg/kg. The 2-hour infusion of AUY922 at 100 mg/kg caused disorganization of the outer segment photoreceptor morphology in male Brown Norway rats; the severity of the disorganization increased with the number of administrations, but was reversible during a 4-week posttreatment period. There was no major difference in ocular response between Brown Norway and Wistar rats. No changes in serum iron levels, and no changes in rhodopsin, PDE6α, β-transducin concentrations, or retinal pigment epithelium-specific protein RPE65 expression were observed after single and multiple infusions of AUY922 at 100 mg/kg compared to vehicle-treated controls. AUY922 retinal toxicity in rats recapitulates and further characterizes that reported in patients and is shown to be reversible, while a precise molecular mechanism for the effect was not determined. - Highlights: • Ocular toxicity of AUY922 was assessed in Brown Norway and Wistar rats. • AUY922 at ≥ 30 mg/kg was generally not well tolerated by rats. • Electroretinography (ERG) changes were observed at doses ≥ 30 mg/kg. • ERG changes at doses ≥ 30 mg/kg were dose-dependent, and fully reversible.« less

  16. A mass and solute balance model for tear volume and osmolarity in the normal and the dry eye.

    PubMed

    Gaffney, E A; Tiffany, J M; Yokoi, N; Bron, A J

    2010-01-01

    Tear hyperosmolarity is thought to play a key role in the mechanism of dry eye, a common symptomatic condition accompanied by visual disturbance, tear film instability, inflammation and damage to the ocular surface. We have constructed a model for the mass and solute balance of the tears, with parameter estimation based on extensive data from the literature which permits the influence of tear evaporation, lacrimal flux and blink rate on tear osmolarity to be explored. In particular the nature of compensatory events has been estimated in aqueous-deficient (ADDE) and evaporative (EDE) dry eye. The model reproduces observed osmolarities of the tear meniscus for the healthy eye and predicts a higher concentration in the tear film than meniscus in normal and dry eye states. The differential is small in the normal eye, but is significantly increased in dry eye, especially for the simultaneous presence of high meniscus concentration and low meniscus radius. This may influence the interpretation of osmolarity values obtained from meniscus samples since they need not fully reflect potential damage to the ocular surface caused by tear film hyperosmolarity. Interrogation of the model suggests that increases in blink rate may play a limited role in compensating for a rise in tear osmolarity in ADDE but that an increase in lacrimal flux, together with an increase in blink rate, may delay the development of hyperosmolarity in EDE. Nonetheless, it is predicted that tear osmolarity may rise to much higher levels in EDE than ADDE before the onset of tear film breakup, in the absence of events at the ocular surface which would independently compromise tear film stability. Differences in the predicted responses of the pre-ocular tears in ADDE compared to EDE or hybrid disease to defined conditions suggest that no single, empirically-accessible variable can act as a surrogate for tear film concentration and the potential for ocular surface damage. This emphasises the need to measure and integrate multiple diagnostic indicators to determine outcomes and prognosis. Modelling predictions in addition show that further studies concerning the possibility of a high lacrimal flux phenotype in EDE are likely to be profitable.

  17. Long term safety and tolerability of Tafluprost 0.0015% vs Timolol 0.1% preservative-free in ocular hypertensive and in primary open-angle glaucoma patients: a cross sectional study.

    PubMed

    Rolle, Teresa; Spinetta, Roberta; Nuzzi, Raffaele

    2017-08-03

    The effects of preservatives of antiglaucoma medications on corneal surface and tear function have been widely shown in literature; it's not the same as regards the active compounds themselves. The purpose of our study was to compare Ocular Surface Disease (OSD) signs and symptoms of Tafluprost 0.0015% versus preservative free (PF) Timolol 0.1% eyedrops in ocular hypertensive (OH) and in primary open-angle glaucoma (POAG) patients. A cross-sectional study included patients in monotherapy for at least 36 months with Tafluprost 0.0015% (27) or PF Timolol 0.1% (24) and 20 healthy age and sex-matched volunteers. All subjects underwent clinical tests (Schirmer I and break-up time), in vivo confocal microscopy (IVCM) and were surveyed using Ocular Surface Disease Index (OSDI) and Glaucoma Symptoms Scale (GSS) questionnaires. The groups were compared with ANOVA, Kruskal-Wallis test, t-test, Mann-Whitney test and Bonferroni's adjustment of p-values. No significant differences were found in questionnaires scores, clinical tests, IVCM variables between therapy groups. Tafluprost 0.0015% group showed significantly higher OSDI score, basal epithelial cells density, stromal reflectivity, sub-basal nerves tortuosity (p = 0.0000, 0.037, 0.006, 0.0000) and less GSS score, number of sub-basal nerves (p = 0.0000, 0.037) than controls but similar clinical tests results (p > 0.05). PF Timolol group had significantly higher OSDI score, basal epithelial cells density, stromal reflectivity and sub-basal nerve tortuosity (p = 0.000, 0.014, 0.008, 0.002), less GSS score, BUT and number of sub-basal nerves (p = 0.0000, 0.026, 0.003) than controls. Compared to PF Timolol 0.1%, Tafluprost 0.0015% showed similar safety with regards to tear function and corneal status and a similar tolerability profile. Both therapy groups show some alterations in corneal microstructure but no side effects on tear function except for an increased tear instability in PF Timolol 0.1% group. Ophtalmologists should be aware that even PF formulations may lead to a mild ocular surface impairment.

  18. Interpreting the corneal response to oxygen: Is there a basis for re-evaluating data from gas-goggle studies?

    PubMed

    Papas, Eric B; Sweeney, Deborah F

    2016-10-01

    When anoxia (0% oxygen) is created within a gas-tight goggle, ocular physiological responses, including corneal swelling, limbal hyperaemia and pH change, are known to vary, depending on the presence or absence of a low, oxygen transmissibility contact lens. A new theory is proposed to account for this discrepancy based on the concept of lid derived oxygen, whereby oxygen originating from the vascular plexus of the palpebral conjunctiva supplements that available to the ocular surface in an open, normally blinking eye, even when the surrounding gaseous atmosphere is anoxic. The effect of a lid derived contribution to corneal oxygenation was assessed by using existing experimental data to model open-eye, corneal swelling behavior as a function of atmospheric oxygen content, both with and without the presence of a contact lens. These models predict that under atmospheric anoxia, contact lens wear results in 13.2% corneal swelling compared with only 5.4% when the lens was absent. Lid derived oxygen acts to provide the ocular surface in the non-contact lens wearing, normally blinking, open-eye with up to 4.7% equivalent oxygen concentration, even within the anoxic environment of a nitrogen filled goggle. Correcting for lid derived oxygen eliminates previously observed discrepancies in corneal swelling behavior and harmonizes the models for the contact lens wearing and gas-goggle cases. On this basis it is proposed that true anoxia at the ocular surface cannot be achieved by atmospheric manipulation (i.e. a gas-goggle) alone but requires an additional presence, e.g. a low, oxygen transmissibility contact lens, to prevent access to oxygen from the eyelids. Data from previously conducted experiments in which the gas-goggle paradigm was used, may have been founded on underestimates of the real oxygen concentration acting on the ocular surface at the time and if so, will require re-interpretation. Future work in this area should consider if a correction for lid derived oxygen is necessary. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Dry Eye Disease: Prevalence, Assessment, and Management.

    PubMed

    Rouen, Patricia A; White, Mary L

    Dry eye disease is a chronic condition of the corneal surface marked by persistent symptoms of irritation or burning that can cause inflammatory damage to the cornea and conjunctiva if untreated. Common risk factors for this syndrome include advancing age, female sex, low humidity environments, systemic medications, and autoimmune disorders. Treatments to relieve symptoms include tear replacement, humidification, improved nutrition, and anti-inflammatory ocular agents. Home healthcare nurses can identify signs and symptoms of dry eye syndrome and initiate strategies that range from warm compresses to physician referrals for more aggressive treatment. Consistent management of this condition improves quality of life and minimizes damage to the ocular surface.

  20. Diabetic corneal neuropathy: clinical perspectives.

    PubMed

    Bikbova, Guzel; Oshitari, Toshiyuki; Baba, Takayuki; Bikbov, Mukharram; Yamamoto, Shuichi

    2018-01-01

    Diabetic keratopathy is characterized by impaired innervation of the cornea that leads to decreased sensitivity, with resultant difficulties with epithelial wound healing. These difficulties in wound healing put patients at risk for ocular complications such as surface irregularities, corneal infections, and stromal opacification. Pathological changes in corneal innervations in diabetic patients are an important early indicator of diabetic neuropathy. The decrease in corneal sensitivity is strongly correlated with the duration of diabetes as well as the severity of the neuropathy. This review presents recent findings in assessing the ocular surface as well as the recent therapeutic strategies for optimal management of individuals with diabetes who are susceptible to developing diabetic neuropathy.

  1. The Effect of Rebamipide on Ocular Surface Disorders Induced by Latanoprost and Timolol in Glaucoma Patients.

    PubMed

    Tokuda, Naoto; Kitaoka, Yasushi; Matsuzawa, Akiko; Miyamoto, Junsuke; Sakae, Shinsuke; Munemasa, Yasunari; Takagi, Hitoshi

    2015-01-01

    Purpose. To examine the efficacy of ophthalmic rebamipide suspensions on ocular surface disorders induced by antiglaucoma eye drops. Patients and Methods. Forty eyes of 40 patients receiving latanoprost (0.005%) and timolol (0.5%) were included in this randomized prospective study. The patients were randomly divided into two groups (n = 20): the rebamipide-treated group and control group. Changes in intraocular pressure, tear film break-up time (TBUT), and corneal epithelial barrier function were evaluated at baseline, 4 weeks, and 8 weeks after rebamipide administration. Furthermore, superficial punctate keratopathy severity was evaluated by scoring the lesion area and density. Results. There was no significant difference in intraocular pressure before and after rebamipide treatment. However, corneal epithelial barrier function improved significantly 4 and 8 weeks after rebamipide treatment. TBUT was partially, but significantly, increased (P = 0.02) 8 weeks after rebamipide treatment, whereas no significant change was observed at 4 weeks. Additionally, a significant decrease in area and density of keratopathy was observed 8 weeks after rebamipide treatment but not at 4 weeks. The control group showed no significant difference compared to baseline. Conclusions. Our data suggests that rebamipide treatment may reduce the occurrence of drug-induced ocular surface disorder.

  2. Rebamipide ophthalmic suspension for the treatment of dry eye syndrome: a critical appraisal

    PubMed Central

    Kashima, Tomoyuki; Itakura, Hirotaka; Akiyama, Hideo; Kishi, Shoji

    2014-01-01

    Rebamipide was initially developed and approved for use in treating gastric ulcers and lesions associated with gastritis. Discovery of its ability to increase gastric mucin led to investigations of its effect on ocular surface mucin and the subsequent development for use in dry eye patients. Investigations have confirmed that rebamipide increases corneal and conjunctival mucin-like substances along with improving corneal and conjunctival injury. Clinically, rebamipide ophthalmic suspensions can effectively treat tear deficiency and mucin-caused corneal epithelial damage, and can restore the microstructure responsible for tear stability. Topical rebamipide has also been shown to be effective in treating other ocular surface disorders such as lagophthalmos, lid wiper epitheliopathy, and persistent corneal erosion. Rebamipide’s ability to modify epithelial cell function, improve tear stability, and suppress inflammation in the absence of any known major side effects suggest that it may be a beneficial first drug of choice for severe dry eye treatment and other ocular surface disorders. This review summarizes the history and development of this innovative dry eye treatment from its initial use as an effective stomach medication to its current use in the treatment of dry eye in Japan. PMID:24940041

  3. Dysfunctional tear syndrome: dry eye disease and associated tear film disorders - new strategies for diagnosis and treatment.

    PubMed

    Milner, Mark S; Beckman, Kenneth A; Luchs, Jodi I; Allen, Quentin B; Awdeh, Richard M; Berdahl, John; Boland, Thomas S; Buznego, Carlos; Gira, Joseph P; Goldberg, Damien F; Goldman, David; Goyal, Raj K; Jackson, Mitchell A; Katz, James; Kim, Terry; Majmudar, Parag A; Malhotra, Ranjan P; McDonald, Marguerite B; Rajpal, Rajesh K; Raviv, Tal; Rowen, Sheri; Shamie, Neda; Solomon, Jonathan D; Stonecipher, Karl; Tauber, Shachar; Trattler, William; Walter, Keith A; Waring, George O; Weinstock, Robert J; Wiley, William F; Yeu, Elizabeth

    2017-01-01

    Dysfunctional tear syndrome (DTS) is a common and complex condition affecting the ocular surface. The health and normal functioning of the ocular surface is dependent on a stable and sufficient tear film. Clinician awareness of conditions affecting the ocular surface has increased in recent years because of expanded research and the publication of diagnosis and treatment guidelines pertaining to disorders resulting in DTS, including the Delphi panel treatment recommendations for DTS (2006), the International Dry Eye Workshop (DEWS) (2007), the Meibomian Gland Dysfunction (MGD) Workshop (2011), and the updated Preferred Practice Pattern guidelines from the American Academy of Ophthalmology pertaining to dry eye and blepharitis (2013). Since the publication of the existing guidelines, new diagnostic techniques and treatment options that provide an opportunity for better management of patients have become available. Clinicians are now able to access a wealth of information that can help them obtain a differential diagnosis and treatment approach for patients presenting with DTS. This review provides a practical and directed approach to the diagnosis and treatment of patients with DTS, emphasizing treatment that is tailored to the specific disease subtype as well as the severity of the condition.

  4. [Effect of anti-inflammatory therapy on the treatment of dry eye syndrome].

    PubMed

    Mrukwa-Kominek, Ewa; Rogowska-Godela, Anna; Gierek-Ciaciura, Stanisława

    2007-01-01

    Dry eye syndrome is a common chronic disease; agents and strategies for its effective management are still lacking. The syndrome tends to be accompanied by ocular surface inflammation; therefore, the use of anti-inflammatory agents might prove beneficial. The authors present up-to-date guidelines, strategies, and efficacy of dry eye syndrome management, including anti-inflammatory treatment. As no diagnostic tests are now available to assess ocular surface inflammation severity, the right timing to launch an anti-inflammatory agent is difficult to determine. Patients with mild intermittent bouts of symptoms which can be alleviated with ophthalmic lubricants do not typically require anti-inflammatory therapy. The latter should be considered in those who do not respond to lubricating drops, obtain poor results on clinical tests, and show symptoms of ocular surface irritation (eg. conjunctivae redness). Anti-inflammatory treatment of dry eye syndrome may include short-term corticosteroids, cyclosporine A emulsion, oral tetracycline therapy, oral omega-3 fatty acid supplements, and autologous serum eye drops. Anti-inflammatory treatment should be safe and effective; potential benefits should be evaluated for each individual patient. The authors have reviewed the advantages of anti-inflammatory treatment in dry eye syndrome, presented in literature.

  5. Preliminary effects of oral uridine on the ocular surface in dry eye patients.

    PubMed

    Chang, Ki Cheol; Oh, Joo Youn; In, Youn Seok; Kim, Mee Kum; Shin, Ki Cheul; Wee, Won Ryang; Lee, Jin Hak; Park, Myung Gyu

    2009-08-01

    We designed a randomized, double blinded, 3-months controlled prospective clinical study to investigate effects of oral uridine on the ocular surface in dry eye patients. Twenty-seven patients who diagnosed as dry eye with lower than 5 mm of wetting in the Schirmer strip, with corneal epithelial erosion and who completely followed-up till 3 months were enrolled. Corneal-conjunctival fluorescein staining, non-anesthetic Schirmer test, impression cytology, and Ocular Surface Disease Index (OSDI) were evaluated in the experimental and placebo groups at the baseline, 1 and 3 months after start of medication in a double blinded manner. Fluorescein stain score of the cornea was markedly decreased in oral uridine group compared to the placebo group at 3 months after medication (P=0.032, Mann-Whitney U test). The Schirmer wetting score for the oral uridine group was significantly increased (P=0.001, Wilcoxon signed rank test) at 3 months and its difference between two groups was statistically significant (P=0.030, Mann-Whitney U test). OSDI scores were significantly decreased at 1 and 3 months in treatment group. Oral uridine is effective in treatment of dry eyes.

  6. Dysfunctional tear syndrome: dry eye disease and associated tear film disorders – new strategies for diagnosis and treatment

    PubMed Central

    Milner, Mark S.; Beckman, Kenneth A.; Luchs, Jodi I.; Allen, Quentin B.; Awdeh, Richard M.; Berdahl, John; Boland, Thomas S.; Buznego, Carlos; Gira, Joseph P.; Goldberg, Damien F.; Goldman, David; Goyal, Raj K.; Jackson, Mitchell A.; Katz, James; Kim, Terry; Majmudar, Parag A.; Malhotra, Ranjan P.; McDonald, Marguerite B.; Rajpal, Rajesh K.; Raviv, Tal; Rowen, Sheri; Shamie, Neda; Solomon, Jonathan D.; Stonecipher, Karl; Tauber, Shachar; Trattler, William; Walter, Keith A.; Waring, George O.; Weinstock, Robert J.; Wiley, William F.; Yeu, Elizabeth

    2017-01-01

    Dysfunctional tear syndrome (DTS) is a common and complex condition affecting the ocular surface. The health and normal functioning of the ocular surface is dependent on a stable and sufficient tear film. Clinician awareness of conditions affecting the ocular surface has increased in recent years because of expanded research and the publication of diagnosis and treatment guidelines pertaining to disorders resulting in DTS, including the Delphi panel treatment recommendations for DTS (2006), the International Dry Eye Workshop (DEWS) (2007), the Meibomian Gland Dysfunction (MGD) Workshop (2011), and the updated Preferred Practice Pattern guidelines from the American Academy of Ophthalmology pertaining to dry eye and blepharitis (2013). Since the publication of the existing guidelines, new diagnostic techniques and treatment options that provide an opportunity for better management of patients have become available. Clinicians are now able to access a wealth of information that can help them obtain a differential diagnosis and treatment approach for patients presenting with DTS. This review provides a practical and directed approach to the diagnosis and treatment of patients with DTS, emphasizing treatment that is tailored to the specific disease subtype as well as the severity of the condition. PMID:28099212

  7. Ocular surface changes in thyroid eye disease.

    PubMed

    Ismailova, Dilyara S; Fedorov, Anatoly A; Grusha, Yaroslav O

    2013-04-01

    To study the incidence and risk factors of ocular surface damage in thyroid eye disease (TED) and to determine histological changes underlying positive vital staining in this condition. Forty-six patients (92 eyes) with TED were included in this study. Routine ophthalmologic examination, Schirmer test I, vital staining and corneal sensitivity were performed. Fifteen patients with positive vital staining underwent impression cytology and incisional biopsy. Positive vital staining with lissamine green was observed in 56 eyes (60.9%), 30 patients (65.2%). The average degree of staining was 4.57 ± 0.44 (National Eye Institute Workshop grading system). Severe dry eye syndrome was found in 16%. The following histological changes of conjunctiva were revealed: significant epithelial dystrophy with cell polymorphism, goblet cells loss, excessive desquamation and epithelial keratinization with local leukocytic infiltration of substantia propria. According to our results dry eye syndrome is present in 65.2% of patients (60.9% eyes) with TED. Significant risk factors of ocular surface damage in TED were exophthalmos, lagophthalmos, palpebral fissure height and lower lid retraction. Positive conjunctival staining results from punctuate epithelial erosions and excessive desquamation of superficial cells. Histopathologic changes detected in conjunctiva consistent with dry eye and are not specific for TED.

  8. Rebamipide ophthalmic suspension for the treatment of dry eye syndrome: a critical appraisal.

    PubMed

    Kashima, Tomoyuki; Itakura, Hirotaka; Akiyama, Hideo; Kishi, Shoji

    2014-01-01

    Rebamipide was initially developed and approved for use in treating gastric ulcers and lesions associated with gastritis. Discovery of its ability to increase gastric mucin led to investigations of its effect on ocular surface mucin and the subsequent development for use in dry eye patients. Investigations have confirmed that rebamipide increases corneal and conjunctival mucin-like substances along with improving corneal and conjunctival injury. Clinically, rebamipide ophthalmic suspensions can effectively treat tear deficiency and mucin-caused corneal epithelial damage, and can restore the microstructure responsible for tear stability. Topical rebamipide has also been shown to be effective in treating other ocular surface disorders such as lagophthalmos, lid wiper epitheliopathy, and persistent corneal erosion. Rebamipide's ability to modify epithelial cell function, improve tear stability, and suppress inflammation in the absence of any known major side effects suggest that it may be a beneficial first drug of choice for severe dry eye treatment and other ocular surface disorders. This review summarizes the history and development of this innovative dry eye treatment from its initial use as an effective stomach medication to its current use in the treatment of dry eye in Japan.

  9. Biopharmaceutical profile of pranoprofen-loaded PLGA nanoparticles containing hydrogels for ocular administration.

    PubMed

    Abrego, Guadalupe; Alvarado, Helen; Souto, Eliana B; Guevara, Bessy; Bellowa, Lyda Halbaut; Parra, Alexander; Calpena, Ana; Garcia, María Luisa

    2015-09-01

    Two optimized pranoprofen-loaded poly-l-lactic-co glycolic acid (PLGA) nanoparticles (PF-F1NPs; PF-F2NPs) have been developed and further dispersed into hydrogels for the production of semi-solid formulations intended for ocular administration. The optimized PF-NP suspensions were dispersed in freshly prepared carbomer hydrogels (HG_PF-F1NPs and HG_PF-F2NPs) or in hydrogels containing 1% azone (HG_PF-F1NPs-Azone and HG_PF-F2NPs-Azone) in order to improve the ocular biopharmaceutical profile of the selected non-steroidal anti-inflammatory drug (NSAID), by prolonging the contact of the pranoprofen with the eye, increasing the drug retention in the organ and enhancing its anti-inflammatory and analgesic efficiency. Carbomer 934 has been selected as gel-forming polymer. The hydrogel formulations with or without azone showed a non-Newtonian behavior and adequate physicochemical properties for ocular instillation. The release study of pranoprofen from the semi-solid formulations exhibited a sustained release behavior. The results obtained from ex vivo corneal permeation and in vivo anti-inflammatory efficacy studies suggest that the ocular application of the hydrogels containing azone was more effective over the azone-free formulations in the treatment of edema on the ocular surface. No signs of ocular irritancy have been detected for the produced hydrogels. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. [Transplantation of autologous labial salivary glands for severe dry eye].

    PubMed

    Luo, Shun-rong; Zou, Liu-he; Yan, Chao; Pan, Zhi-qiang; Liu, Jing-ming; Chen, Zhi-yuan; Yin, Wei-hong

    2013-01-01

    Autologous labial salivary gland transplantation has been a promising alternative for the treatment of severe dry eye. In this article, we describe the results of the ocular surface changes after labial salivary gland transplantation and investigate the feasibility of this treatment. The results of this technique in 8 patients (eyes) who suffered from severe dry eye were prospectively analyzed after surgery (follow-up of 6 months). The best-corrected visual acuity, Schirmer I test, degree of discomfort, usage of pharmaceutical tear substitutes, tear interferometry and slit lamp examination were investigated at different time before and after surgery. All grafts remained viable and the survival rate is 100%. All patients showed significant increase in the Schirmer's test and they expressed great improvement in their ocular discomfort. The use of artificial tear substitutes was reduced because of the increased ocular surface lubrication. Although the authors' long-term experience still is limited, we believe that the procedure is a promising alternative approach for severe dry eye.

  11. Dry Eye Syndrome in Menopause and Perimenopausal Age Group.

    PubMed

    Peck, Travis; Olsakovsky, Leslie; Aggarwal, Shruti

    2017-01-01

    Dry eye disease (DED) is a multifactorial ocular surface disease that causes symptoms of ocular pain, discomfort, and decreased visual acuity. It significantly affects quality of life of patients. It is more prevalent in the females and is being specifically in the menopausal and postmenopausal age group. This is believed to be due to the changes in balance of sex hormones. Sex hormones - estrogens and androgens - influence production of all components of the tear film including aqueous layer, lipid, and mucin. Various mechanisms such as decrease in hormonal levels, shift in feedback mechanisms, and changes in receptor receptivity interplay to alter the ocular surface homeostasis and subsequently result in DED. Several studies have suggested potential role of hormone replacement therapy in menopause-associated dry eye symptoms. The purpose of this review is to help the non ophthalmic physicians about DED encountered commonly in menopausal age group. It is important for primary care physicians to understand DED due to its high prevalence, often debilitating symptoms and the potentially preventable and treatable nature of the condition.

  12. Impact of Eye Cosmetics on the Eye, Adnexa, and Ocular Surface.

    PubMed

    Ng, Alison; Evans, Katharine; North, Rachel V; Jones, Lyndon; Purslow, Christine

    2016-07-01

    Despite the fact that cosmetic products undergo rigorous testing to ensure they are safe for human use, some users report mild discomfort following their application. The cutaneous changes, such as allergic dermatitis, are well reported, but the ocular changes associated with eye cosmetic use are less so. Some pigmented cosmetic products may accumulate within the lacrimal system and conjunctivae over many years of use, but immediate reports of eye discomfort after application are most common. Changes to the tear film and its stability may occur shortly after application, and contact lens wearers can also be affected by lens spoliation from cosmetic products. Additionally, creams used in the prevention of skin aging are often applied around the eyes, and retinoids present in these formulations can have negative effects on meibomian gland function and may be a contributing factor to dry eye disease. The aim of this review is to summarize current knowledge regarding the impact of cosmetic products on the eye, ocular surface, and tear film.

  13. Novel surface-modified nanostructured lipid carriers with partially deacetylated water-soluble chitosan for efficient ocular delivery.

    PubMed

    Tian, Baocheng; Luo, Qiuhua; Song, Shuangshuang; Liu, Dandan; Pan, Hao; Zhang, Wenji; He, Ling; Ma, Shilin; Yang, Xinggang; Pan, Weisan

    2012-03-01

    The objective of this study was to propose novel surface-modified nanostructured lipid carriers with partially deacetylated water-soluble chitosan (NLC-PDSC) as an efficient ocular delivery system to improve its transcorneal penetration and precorneal retention. PDSC with a deacetylation degree of around 50% was synthesized using an improved method. NLC loaded with flurbiprofen (FB) were prepared by melt emulsification method. They presented spherical morphology under both transmission electron microscope and scanning electron microscope. After coating with 0.15% (w/v) PDSC solution, the NLC showed a core-shell structure and a reversed zeta potential. The enhanced transcorneal penetration of the coated NLC was evaluated using isolated rabbit corneas, with significantly increased apparent permeability coefficient being 1.40- and 1.75-fold of the NLC and FB phosphate solution (FB-sol; p < 0.05), respectively. Precorneal retention assessed by gamma scintigraphy in vivo showed that the area under the remaining activity-time curve of the PDSC-coated formulation was 1.3-fold of the NLC and 2.4-fold of FB-sol. Moreover, in vivo ocular tolerance study indicated that there was no difference in irritation between the coated and noncoated NLC. In conclusion, novel NLC demonstrate high potential for ocular drug delivery. Copyright © 2011 Wiley Periodicals, Inc.

  14. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology

    PubMed Central

    Ouchi, M; Kinoshita, S

    2015-01-01

    Purpose To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. Methods LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Results Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. Conclusion With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies. PMID:25744442

  15. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

    PubMed

    Ouchi, M; Kinoshita, S

    2015-05-01

    To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.

  16. Ozone depletion and solar ultraviolet radiation: ocular effects, a United nations environment programme perspective.

    PubMed

    Cullen, Anthony P

    2011-07-01

    To describe he role played by the United Nations Environmental Effects Panel with respect to the ocular effects of stratospheric ozone depletion and present the essence of the Health Chapter of the 2010 Assessment. A consideration of solar ultraviolet radiation (UVR) at the Earth's surface as it is affected by atmospheric changes and how these influence sunlight-related eye diseases. A review of the current Assessment with emphasis on pterygium, cataract, ocular melanoma, and age-related macular degeneration. Although the ozone layer is projected to recover slowly in the coming decades, continuing vigilance is required regarding exposure to the sun. Evidence implicating solar UVR, especially UVB, in every tissue of the eye continues to be amassed. The need for ocular UV protection existed before the discovery of the depletion of the ozone layer and will continue even when the layer fully recovers in approximately 2100.

  17. Glycobiology of ocular angiogenesis

    PubMed Central

    Markowska, Anna I; Cao, Zhiyi; Panjwani, Noorjahan

    2014-01-01

    Ocular neovascularization can affect almost all the tissues of the eye: the cornea, the iris, the retina, and the choroid. Pathological neovascularization is the underlying cause of vision loss in common ocular conditions such as diabetic retinopathy, retinopathy of prematurity and age-related macular neovascularization. Glycosylation is the most common covalent posttranslational modification of proteins in mammalian cells. A growing body of evidence demonstrates that glycosylation influences the process of angiogenesis and impacts activation, proliferation, and migration of endothelial cells as well as the interaction of angiogenic endothelial cells with other cell types necessary to form blood vessels. Recent studies have provided evidence that members of the galectin class of β-galactoside-binding proteins modulate angiogenesis by novel carbohydrate-based recognition systems involving interactions between glycans of angiogenic cell surface receptors and galectins. This review discusses the significance of glycosylation and the role of galectins in the pathogenesis of ocular neovascularization. PMID:25108228

  18. Dry eye symptoms align more closely to non-ocular conditions than to tear film parameters.

    PubMed

    Galor, Anat; Felix, Elizabeth R; Feuer, William; Shalabi, Nabeel; Martin, Eden R; Margolis, Todd P; Sarantopoulos, Constantine D; Levitt, Roy C

    2015-08-01

    To evaluate the relationship between dry eye symptoms, non-ocular conditions and tear film parameters. Cross-sectional study. The study population consisted of patients who were seen in the Miami Veterans Affairs eye clinic. Patients filled out standardised questionnaires assessing dry eye symptoms (dry eye questionnaire 5 (DEQ5) and ocular surface disease index (OSDI)), non-ocular pain, depression and post-traumatic stress disorder (PTSD), and also underwent measurement of tear film parameters. Correlations between dry eye symptoms and non-ocular conditions as compared with tear film parameters. 136 patients with a mean age of 65 (SD 11) years participated in the study. All correlations between the dry eye questionnaire scores (DEQ5 and OSDI) and (A) self-reported non-ocular pain measures (numerical rating scale and pain history), (B) depression and (C) PTSD were significant and moderate in strength (Pearson's coefficient 0.24 to 0.60, p<0.01 for all). All correlations between the dry eye questionnaires and tear film measures were weak (Pearson's coefficient -0.10 to 0.18) and most were not significant. Multivariable linear regression analyses revealed that PTSD and non-ocular pain more closely associated with dry eye symptoms than did tear film parameters. Specifically, non-ocular pain and PTSD accounted for approximately 36% of the variability in DEQ5 scores (R=0.60) and approximately 40% of variability in OSDI scores (R=0.64). Of note, none of the tear parameters remained significantly associated with dry eye symptoms in either model. Dry eye symptoms more closely align to non-ocular pain, depression and PTSD than to tear film parameters. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Profile of ocular trauma in industries-related hospital.

    PubMed

    Shashikala, P; Sadiqulla, Mohammed; Shivakumar, D; Prakash, K H

    2013-05-01

    Ocular trauma is a worldwide cause of visual morbidity, a significant proportion of which occurs in the industrial workplace and includes a spectrum of simple ocular surface foreign bodies, abrasions to devastating perforating injuries causing blindness. Being preventable is of social and medical concern. A prospective case series study, to know the profile of ocular trauma at a hospital caters exclusively to factory employees and their families, to co-relate their demographic and clinical profile and to identify the risk factors. Patients with ocular trauma who presented at ESIC Model hospital, Rajajinagar, Bangalore, from June 2010 to May 2011 were taken a detailed demographic data, nature and cause of injury, time interval between the time of injury and presentation along with any treatment received. Ocular evaluation including visual acuity, anterior and posterior segment findings, intra-ocular pressure and gonio-scopy in closed globe injuries, X-rays for intraocular foreign body, B-scan and CT scan were done. Data analyzed as per the ocular trauma classification group. The rehabilitation undertaken medically or surgically was analyzed. At follow-up, the final best corrected visual acuity was noted. A total of 306 cases of ocular trauma were reported; predominantly in 20-40 year age group (72.2%) and in men (75%). The work place related cases were 50.7%and of these, fall of foreign bodies led the list. Visual prognosis was poorer in road traffic accidents rather than work place injuries owing to higher occurrence of open globe injuries and optic neuropathy. Finally, 11% of injured cases ended up with poor vision. Targeting groups most at risk, providing effective eye protection, and developing workplace safety cultures may together reduce occupational eye injuries.

  20. Colored corn starch dust explosion-related ocular injuries at a Taiwan water park: A preliminary report from a single medical center

    PubMed Central

    Liao, Yi-Lin; Yeh, Lung-Kun; Tsai, Yueh-Ju; Chen, Shin-Yi

    2016-01-01

    Purpose: To elucidate the manifestations of ocular injuries in the colored corn starch dust explosion at a Taiwan water park. Methods: This is a retrospective, non-comparative, consecutive-interventional case series. Fifty explosion-injury patients on 27 June 2015 treated at Chang-Gung Memorial Hospital, Linkou, were included. Thorough ophthalmic examinations were based on emergent triage and consecutive ophthalmological consultations. Multiple ocular and systemic parameters were assessed. Results: Of the 100 eyes in the 50 cases reviewed, 22 cases were male and 28 cases were female. The mean age was 22.08 ± 4.64 years, and the mean burn total body surface area (TBSA) of patients was 45.92 ± 20.30%. Of the 50 patients, 20 had Grade 1 ocular burns, and the others were without ocular involvement. Two of the 20 cases that presented Grade 1 ocular burns died within 1 month due to other systemic complications. The most common ocular manifestations among those with ocular injuries included periocular swelling (75%), followed by conjunctival chemosis (65%), conjunctival hyperemia (50%), singed eyelashes (20%), cornea epithelial defects (10%), and punctate keratopathy (5%). It is worth mentioning that one patient developed herpes simplex keratitis due to stress 3 weeks after being burned. Half of the 50 patients had facial burns. Specifically, the patients with a greater TBSA presented more significant ocular-burn manifestations than those patients with lower TBSA. Conclusion: Prompt ophthalmologic consultations are particularly necessary for mass burn-casualty patients with facial burns, inhalation injuries, and greater TBSA. The inspection and control of all ignition sources and the manipulation of dust with low concentrations and in an open space are crucial factors to prevent future dust explosions. PMID:29018726

  1. The Effect of Ambient Titanium Dioxide Microparticle Exposure to the Ocular Surface on the Expression of Inflammatory Cytokines in the Eye and Cervical Lymph Nodes.

    PubMed

    Eom, Youngsub; Song, Jong Suk; Lee, Hyun Kyu; Kang, Boram; Kim, Hyeon Chang; Lee, Hyung Keun; Kim, Hyo Myung

    2016-12-01

    To investigate the ocular immune response following exposure to airborne titanium dioxide (TiO2) microparticles. Rats in the TiO2-exposed group (n = 10) were exposed to TiO2 particles for 2 hours twice daily for 5 days, while the controls (n = 10) were not. Corneal staining score and tear lactic dehydrogenase (LDH) activity were measured to evaluate ocular surface damage, serum immunoglobulin (Ig) G and E were assayed by using enzyme-linked immunosorbent assay, and the size of cervical lymph nodes was measured. In addition, the expression of interleukin (IL)-4, IL-17, and interferon (IFN)-γ in the anterior segment of the eyeball and cervical lymph nodes was measured by immunohistochemistry, real-time reverse transcription-polymerase chain reaction (RT-PCR), and Western blot analysis. Median corneal staining score (3.0), tear LDH activity (0.24 optical density [OD]), and cervical lymph node size (36.9 mm2) were significantly higher in the TiO2-exposed group than in the control group (1.0, 0.13 OD, and 26.7 mm2, respectively). Serum IgG and IgE levels were found to be significantly elevated in the TiO2-exposed group (P = 0.021 and P = 0.021, respectively). Interleukin 4 expression was increased in the anterior segment of the eyeball and lymph nodes following TiO2 exposure, as measured by immunostaining, real-time RT-PCR, and Western blot. In addition, IL-17 and IFN-γ levels were also increased following TiO2 exposure compared to controls as measured by immunostaining. Exposure to airborne TiO2 induced ocular surface damage. The Type 2 helper T-cell pathway seems to play a dominant role in the ocular immune response following airborne TiO2 exposure.

  2. Evaluation of ocular and general safety following repeated dosing of dexamethasone phosphate delivered by transscleral iontophoresis in rabbits.

    PubMed

    Patane, Michael A; Schubert, William; Sanford, Thomas; Gee, Raymond; Burgos, Melissa; Isom, William P; Ruiz-Perez, Begona

    2013-10-01

    To evaluate the toxicokinetics and tolerability (local ocular and general toxicity) of the anti-inflammatory agent, dexamethasone phosphate (a prodrug of dexamethasone) delivered to the eye in rabbits by transscleral iontophoresis. Female rabbits (n=6/group) received dexamethasone phosphate (40 mg/mL ophthalmic solution, EGP-437) transsclerally to the right eye (OD) using the Eyegate(®) II ocular iontophoresis delivery system once biweekly for 24 consecutive weeks at current doses of 10, 14, and 20 mA-min and current levels up to, and including -4 mA for 3.5-5 min. The study included 2 control groups (n=6/group): (1) a noniontophoresis control [an ocular applicator-loaded citrate buffer (placebo) without current] and (2) an iontophoresis control (a citrate buffer plus cathode iontophoresis at 20 mA-min, -4 mA for 5 min). Recoverability was evaluated 4 weeks following the last dose in 2 animals per group. The left eye (OS) was untreated and served as an internal control for each animal. Ocular and general safety of dexamethasone phosphate and dexamethasone were assessed. Other evaluations included toxicokinetics, ophthalmic examinations, intraocular pressure (IOP) measurements, electroretinographs, clinical observations, body weight, hematology and serum chemistry, gross necropsy, organ weight, and microscopic histopathology. The biweekly transscleral iontophoresis with either the citrate buffer or dexamethasone phosphate at cathodic doses up to, and including 20 mA-min and currents up to, and including -4 mA for 24 weeks was well-tolerated. Transient signs of conjunctival hyperemia and chemosis, mild corneal opacity, and fluorescein staining of the cornea were noted and attributed to expected ocular reactions to the temporary placement of the ocular applicator and application of iontophoresis. There were no dexamethasone phosphate-, dexamethasone-, or iontophoresis-related effects on IOP, electroretinography, or histopathology. Reductions in body weight gain, anemia, decreased leukocyte and lymphocyte counts, compromised liver function, enlarged liver, and reduced spleen weight were consistent with systemic corticosteroid-mediated pharmacology, repeated use of anesthesia, stress, and sedentariness, and unlikely to be related to iontophoresis application. The results of this investigation suggest that repeated transscleral iontophoresis with dexamethasone phosphate may be safe for use as a treatment for inflammatory ocular disorders that require prolonged and/or repeated corticosteroid therapy.

  3. Goblet Cells of the Conjunctiva: A Review of Recent Findings

    PubMed Central

    Gipson, Ilene K

    2016-01-01

    Goblet cells within the conjunctival epithelium are specialized cells that secrete mucins onto the surface of the eye. Recent research has demonstrated new characteristics of the cells, including factors influencing their differentiation, their gene products and their functions at the ocular surface. The following review summarizes the newly discovered aspects of the role of Spdef, a member of the Ets transcription factor family in conjunctival goblet cell differentiation, the newly discovered goblet cell products including claudin2, the Wnt inhibitor Frzb, and the transmembrane mucin Muc16. The current concepts of conjunctival goblet cell function, including debris removal and immune surveillance are reviewed, as are changes in the goblet cell population in ocular surface diseases. Major remaining questions regarding conjunctival cell biology are discussed. PMID:27091323

  4. Gene therapy for ocular diseases meditated by ultrasound and microbubbles (Review)

    PubMed Central

    WAN, CAIFENG; LI, FENGHUA; LI, HONGLI

    2015-01-01

    The eye is an ideal target organ for gene therapy as it is easily accessible and immune-privileged. With the increasing insight into the underlying molecular mechanisms of ocular diseases, gene therapy has been proposed as an effective approach. Successful gene therapy depends on efficient gene transfer to targeted cells to prove stable and prolonged gene expression with minimal toxicity. At present, the main hindrance regarding the clinical application of gene therapy is not the lack of an ideal gene, but rather the lack of a safe and efficient method to selectively deliver genes to target cells and tissues. Ultrasound-targeted microbubble destruction (UTMD), with the advantages of high safety, repetitive applicability and tissue targeting, has become a potential strategy for gene- and drug delivery. When gene-loaded microbubbles are injected, UTMD is able to enhance the transport of the gene to the targeted cells. High-amplitude oscillations of microbubbles act as cavitation nuclei which can effectively focus ultrasound energy, produce oscillations and disruptions that increase the permeability of the cell membrane and create transient pores in the cell membrane. Thereby, the efficiency of gene therapy can be significantly improved. The UTMD-mediated gene delivery system has been widely used in pre-clinical studies to enhance gene expression in a site-specific manner in a variety of organs. With reasonable application, the effects of sonoporation can be spatially and temporally controlled to improve localized tissue deposition of gene complexes for ocular gene therapy applications. In addition, appropriately powered, focused ultrasound combined with microbubbles can induce a reversible disruption of the blood-retinal barrier with no significant side effects. The present review discusses the current status of gene therapy of ocular diseases as well as studies on gene therapy of ocular diseases meditated by UTMD. PMID:26151686

  5. An animal model (guinea pig) of ocular siderosis: histopathology, pharmacology, and electrophysiology.

    PubMed

    Mumcuoglu, Tarkan; Ozge, Gokhan; Soykut, Bugra; Erdem, Onur; Gunal, Armagan; Acikel, Cengizhan

    2015-03-01

    Ocular siderosis is a rare sight-threatening complication that occurs after a penetrating ocular injury by an iron-containing foreign body. The purposes of this study were to (i) investigate the histopathology, electrophysiology and iron levels/accumulation in ocular siderosis using an animal (Guinea pig) model and (ii) determine the appropriate timing for follow-up foreign body-removal surgery. Thirty guinea pigs were divided into five groups (n = 6 animals/group). On day-1, an iron body was inserted into the vitreous of the right eye of all animals; the left eyes were left undisturbed and were used as controls. At the end of each week during the 5-week study period, electroretinography (ERG) was performed on all animals in one of the five groups. Each animal in that group was sacrificed, after which both eyes were enucleated for histopathological and pharmacological evaluation of intraocular iron. Accumulated iron levels of study eyes were significantly higher than those of control eyes (135.13 and 13.55 μg/g, respectively, p < 0.01). In addition, there was a significant decrease in electrophysiological responses of study eyes. During the first week, iron levels were higher in study eyes than control eyes, but neither histological iron accumulation nor decreased electrophysiological responses could be detected. By the end of the second week, increased iron accumulation was observed histologically in intraocular tissues, along with signs of retinal toxicity, as verified by decreased electrophysiological responses. The present study indicates that the 14th day after a penetrating eye injury by an iron-containing intraocular foreign body represents a clinically critical threshold, after which structural damage to and functional alterations in ocular tissues occur.

  6. An improved method for emergent decontamination of ocular and dermal hydrofluoric acid splashes.

    PubMed

    Soderberg, Kjell; Kuusinen, Petri; Mathieu, Laurence; Hall, Alan H

    2004-08-01

    Accidental hydrofluoric acid (HF) splashes often occur in industrial settings. HF easily penetrates into tissues by initial acid action allowing fluoride ions to penetrate deeply, chelating calcium and magnesium. Resultant hypocalcemia and hypomagnesemia can be fatal. This report describes the utilization of Hexafluorine--a hypertonic, amphoteric, chelating decontamination solution--in workplaces where water decontamination followed by calcium gluconate inunction failed to prevent HF burns and systemic toxicity. Between 1998 and 1999, 16 cases of ocular and dermal HF splashes with either 70% HF or 6% HF/15% nitric acid (HNO3) were decontaminated with Hexafluorine at the worksite. HF burns did not develop and medical treatment other than initial decontamination was not reQuired in 12/16 (75%). In 7/16 (44%) cases, lost work time corresponded to duration of hospital observation (mean < 1 d).

  7. A review of scoring systems for ocular involvement in chronic cutaneous bullous diseases.

    PubMed

    Lee, Brendon W H; Tan, Jeremy C K; Radjenovic, Melissa; Coroneo, Minas T; Murrell, Dedee F

    2018-05-22

    Epidermolysis bullosa (EB) and autoimmune blistering diseases (AIBD) describe a group of rare chronic dermatoses characterized by cutaneous fragility and blistering. Although uncommon, significant ocular surface disease (OSD) may occur in both and require ophthalmological assessment. Disease scoring systems have a critical role in providing objective and accurate assessment of disease severity. The objectives of this report were, firstly, to document the prevalence and severity of ocular involvement in EB/AIBD. Secondly, to review and evaluate existing ocular and systemic scoring systems for EB/AIBD. Finally, to identify areas where further development of ocular specific tools in EB/AIBD could be pursued. A literature search was performed in October 2017 utilising Medline, Embase, and Scopus databases. The results were restricted by date of publication, between 01.01.1950 and 31.10.2017. The reference lists of these articles were then reviewed for additional relevant publications. Articles of all languages were included if an English translation was available. Articles were excluded if they were duplicates, had no reference to ocular involvement in EB/AIBD or described ocular involvement in other diseases. Descriptions of ocular involvement in EB/AIBD were identified in 88 peer-reviewed journal articles. Findings reported include but are not limited to: cicatrising conjunctivitis, meibomian gland dysfunction, dry eye disease, trichiasis, symblepharon, fornix fibrosis, keratopathy, ectropion/entropion, ankyloblepharon, corneal ulceration, visual impairment and blindness. Although scoring systems exist for assessment of OSD in mucous membrane pemphigoid, no such tools exist for the other AIBD subtypes or for EB. Several systemic scoring systems exist in the dermatological literature that are efficacious in grading overall EB/AIBD severity, but have limited inclusion of ocular features. To the best of our knowledge, there is no recognised or validated scoring systems which comprehensively stages or grades the spectrum of ocular manifestations in EB/AIBD. There are a range of ocular complications documented in EB and AIBD. Development of a comprehensive ocular scoring system for EB/AIBD which incorporates the delineation between 'activity' and 'damage' would facilitate more objective patient assessment, improved longitudinal monitoring, comparison of intervention outcomes, and provide commonality for discussion of these patients due to the multidisciplinary nature of their care.

  8. Frequency and risk factors associated with dry eye in patients attending a tertiary care ophthalmology center in Mexico City.

    PubMed

    Martinez, Jaime D; Galor, Anat; Ramos-Betancourt, Nallely; Lisker-Cervantes, Andrés; Beltrán, Francisco; Ozorno-Zárate, Jorge; Sánchez-Huerta, Valeria; Torres-Vera, Marco-Antonio; Hernández-Quintela, Everardo

    2016-01-01

    The purpose of this study was to ascertain the frequency and risk factors of dry eye (DE) among patients attending a tertiary care ophthalmology center in Mexico. Approximately 338 consecutive new patients attending a tertiary care ophthalmology center in Mexico City underwent an ocular surface examination, which included tear film break-up time, fluorescein corneal staining, Schirmer's test, and evaluation of meibum quality. Symptoms of DE were evaluated by the Ocular Surface Disease Index and Dry Eye Questionnaire-5. Information on demographics, exposures, past medical and ocular history, and medications was also collected. The frequency of severe DE symptoms was found to be 43% based on the Ocular Surface Disease Index and 30% based on Dry Eye Questionnaire-5. Risk factors significantly associated with increased DE symptoms included dry mouth and gastrointestinal ulcer medications. With regard to signs, aqueous tear deficiency was a less-frequent finding (22%) in our population than evaporative deficiency (94%). Risk factors associated with aqueous tear deficiency were dry mouth and diuretic use. No risk factors were associated with evaporative deficiency. Risk factors associated with meibomian gland dysfunction included old age, male sex, arthritis, and use of an antihypertensive. The only risk factor associated with corneal staining was dry mouth. This is the first study to demonstrate the frequency of symptomatic and clinical DE in a tertiary care ophthalmology center in Mexico. The frequency of DE ranged from 30% using a symptomatic definition to 94% using objective measures. Different risk factors were found for different aspects of DE, suggesting differing underlying pathophysiologies behind different DE subtypes.

  9. A Comparison of the Effects of Benzalkonium Chloride on Ocular Surfaces between C57BL/6 and BALB/c Mice

    PubMed Central

    Yang, Qian; Zhang, Yafang; Liu, Xiuping; Wang, Nan; Song, Zhenyu; Wu, Kaili

    2017-01-01

    Models of benzalkonium chloride (BAC)-induced ocular disruption have been created and are widely used in various animals. This study aimed to compare the effects of BAC on the ocular surfaces of C57BL/6 and BALB/c mice. C57BL/6 and BALB/c mice were treated separately with BAC eye-drops at different concentrations. Eyes were evaluated by scoring epithelial disruption, corneal opacity and neovascularization in vivo, and by histological assays with hematoxylin/eosin (H/E) and periodic acid-Schiff stainings and by determining the expression of inflammatory factors in vitro on Days 7 and 14. The in vivo corneal epithelial disruption, corneal edema/opacity and neovascularization, which were in accordance with the results of the H/E staining and peaked at Day 7, were observed in a dose-dependent manner in the BAC-treated mice, with more severe signs in the C57BL/6 mice than the BALB/c mice. The loss of conjunctival goblet cells in the conjunctivas and the increasing expression of monocyte chemoattractant protein 1 (MCP-1), growth-regulated protein alpha (GROa) and macrophage inflammatory protein-1 alpha (MIP-1a) in the corneas were found in a dose-dependent manner in both strains of mice. Topical application of BAC can dramatically disrupt the ocular surfaces of C57BL/6 and BALB/c mice, and the disruptions were much more severe in the C57BL/6 mice that received high doses of BAC. PMID:28245636

  10. Current concepts of ocular adnexal surgery

    PubMed Central

    Borrelli, Maria; Geerling, Gerd

    2013-01-01

    Ophthalmic Plastic and Reconstructive Surgery is a specialized area of ophthalmology that deals with the management of deformities and abnormalities of the eyelids, lacrimal system and the orbit. An ophthalmoplastic surgeon is able to identify and correct abnormalities of the ocular adnexae such as ectropion, lid retraction, conjunctival scarring with severe entropion, that can cause secondary ocular surface disorders; manage patients with watering eye, and when needed intervene with a dacryocystorhinostomy by external or endonasal approach and moreover minimize disfigurement following enucleation or evisceration and prevent further corneal damage, alleviate complains of tearing and grittiness, but also cosmetic complaints in patients with Graves’ orbitopathy. Aim of this manuscript was to review current established and recently evolving surgical procedures. PMID:26504698

  11. Glycerogelatin-based ocular inserts of aceclofenac: physicochemical, drug release studies and efficacy against prostaglandin E₂-induced ocular inflammation.

    PubMed

    Mathurm, Manish; Gilhotra, Ritu Mehra

    2011-01-01

    An attempt has been made in the present study to formulate soluble ocular inserts of aceclofenac to facilitate the bioavailability of the drug into the eye, as no eye drop solution could be formulated. Glycero-gelatin ocular inserts/films were prepared and physicochemical parameters and drug release profiles of glycerol-gelatin films of aceclofenac were compared with surface cross-linked films of similar compositions. Ocular irritation of the developed formulation was also checked by HET-CAM test and efficacy of the developed formulation against prostaglandin-induced ocular inflammation in rabbit eye was determined. The non-cross-linked films showed poor mechanical, physicochemical properties, and very little potential of sustaining drug release, however cross-linking the films enhanced tensile strength by 70%, but elasticity decreased by 95%. The cross-linked ocular inserts showed less swelling than non-cross-linked. Formulation AF8 (20% gelatin and 70% glycerin, treated by cross-linker for 1 h) demonstrated the longest drug release for 24 h. As per the kinetic models all films showed a constant drug release with Higuchi diffusion mechanism. Formulation was found to be practically non-irritant. The optimized formulation was tested and compared with eye drops of aceclofenac for anti-inflammatory activity in rabbits against PGE₂-induced inflammation. In vivo studies with developed formulation indicated a significant inhibition of PGE₂-induced PMN migration as compared to eye drops. In conclusion, ocular inserts of aceclofenac was found promising as it achieved sustained drug release and better pharmacodynamic activity.

  12. Rapid and selective removal of preservative from ophthalmic formulations during eyedrops instillation.

    PubMed

    Hsu, Kuan-Hui; Chauhan, Anuj

    2015-11-01

    About 70% of eyedrops contain benzalkonium chloride (BAK) as a preservative to prevent the growth of microorganisms. While preservatives are mandated to maintain sterility, many patients exhibit irritation and toxicity to such compounds. We propose to mitigate the ocular toxicity in the ocular formulations without compromising sterility by designing a device that can be incorporated into an eyedrops bottle to selectively remove the preservatives during the process of drop instillation. Here, we specifically focus on macroporous poly(2-hydroxyethyl methacrylate) (pHEMA) gel due to its excellent biocompatibility and high partition coefficient for BAK. In addition to specific selectivity for BAK, the device also requires high hydraulic permeability to allow drop dispensing without excessive pressure drop. The pHEMA monolith can remove nearly 100% of contained BAK from a 25 ml, 0.012% BAK solution with negligible uptake of the hydrophilic drugs such as timolol and dorzolamide. The filter, however, had to be pre-equilibrated with hydrophobic drugs to reach a high separation of BAK without reducing the concentration of the active drug. The average hydraulic permeability of the filter was 0.025 Darcy, which is about 5-fold lower than the ideal value. Incorporation of a pHEMA macroporous gel into an eyedrops bottle can virtually eliminate the exposure of the eyes to the preservatives without compromising the sterility. Our novel design can eliminate the preservative induced toxicity from eyedrops thereby impacting hundreds of millions of patients with chronic ophthalmic diseases such as glaucoma and dry eyes. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Improved Therapeutic Regimens for Treatment of Post-Traumatic Ocular Infections

    DTIC Science & Technology

    2011-05-01

    cystoid macular oedema in uveitis . Clin. Exp. Ophthalmol. 29, 2–6 (2001). 36 Campochiaro PA, Lim JI. Aminoglycoside toxicity in the treatment of...TELEPHONE NUMBER (include area code) Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 Improved Therapeutic Regimens for Treatment of...injury and adequate treatment . This proposal was designed to analyze the effectiveness of antibiotics, anti-inflammatory drugs, and non-conventional

  14. Sodium toxicity and pathology associated with exposure of waterfowl to hypersaline playa lakes of southeast New Mexico

    USGS Publications Warehouse

    Meteyer, C.U.; Dubielzig, R.D.; Dein, F.J.; Baeten, L.A.; Moore, M.K.; Jehl, J.R.; Wesenberg, K.E.

    1997-01-01

    Cause of mortality was studied in waterfowl in hypersaline playa lakes of southeast New Mexico during spring and fall migration. Mortality was not common in wild ducks resting on the playas during good weather. However, when birds remained on the lakes for prolonged periods of time, such as during experimental trials and stormy weather, a heavy layer of salt precipitated on their feathers. Sodium toxicity was the cause of death for all experimental mallards housed on playa water and for 50% of the wild waterfowl found moribund or dead during the spring of 1995. Gross lesions included heavy salt precipitation on the feathers, ocular lens opacities, deeply congested brains, and dilated, thin-walled, fluid-filled cloacae. Microscopic lesions in the more severely affected birds included liquefaction of ocular lens cortex with lens fiber swelling and multifocal to diffuse ulcerative conjunctivitis with severe granulocytic inflammation, edema, and granulocytic vasculitis resulting in thrombosis. Inflammation similar to that seen in the conjunctiva occasionally involved the mucosa of the mouth, pharynx, nasal turbinates, cloaca, and bursa. Transcorneal movement of water in response to the hypersaline conditions on the playa lakes or direct contact with salt crystals could induce anterior segment dehydration of the aqueous humor and increased osmotic pressure on the lens, leading to cataract formation.

  15. Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function.

    PubMed

    Hayashi, Ken; Hirata, Akira; Yoshida, Motoaki; Yoshimura, Koichi; Hayashi, Hideyuki

    2012-08-01

    To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. Case-control study. Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Nanostructured lipid carriers as novel ophthalmic delivery system for mangiferin: improving in vivo ocular bioavailability.

    PubMed

    Liu, Rui; Liu, Zhidong; Zhang, Chengui; Zhang, Boli

    2012-10-01

    The aim of this study was to develop a novel nanostructured lipid carriers (NLCs) system to improve ocular bioavailability of mangiferin (MGN) for the potential treatment of cataract. The physicochemical properties of MGN-loaded NLC (MGN-NLC) formulation were characterized by particle size, polydispersity index, zeta potential, entrapment efficiency, drug loading, morphological property, and crystalline state. in vitro characteristics were investigated by drug release from NLC system, physical stability, and corneal permeation through excised rabbit cornea. Moreover, in vivo ocular tolerability was assessed by a modified Draize test and histological microscopy. Preocular retention capability was evaluated by slit-lamp observation. Pharmacokinetic study in the aqueous humor was performed by microdialysis technique. Transmission electron microscopy depicted spherical and uniform morphology. Differential scanning calorimetry and X-ray diffractometry displayed imperfect crystalline lattice. The optimized MGN-NLC formulation exhibited a sustained drug release with 3 months stability and 4.31-fold increase of in vitro corneal permeation. Furthermore, in vivo studies exhibited a high tolerance in the ocular tissues and prolonged drug retention capacity on the corneal surface. Finally, pharmacokinetic study suggested a 5.69-fold increase of ocular bioavailability compared with MGN solution (MGN-SOL). Therefore, NLC system is a promising approach for ocular delivery of MGN. Copyright © 2012 Wiley Periodicals, Inc.

  17. Microscopic and spectroscopic evaluation of novel PLGA-chitosan Nanoplexes as an ocular delivery system.

    PubMed

    Jain, Gaurav K; Pathan, Shadab A; Akhter, Sohail; Jayabalan, Nirmal; Talegaonkar, Sushma; Khar, Roop K; Ahmad, Farhan J

    2011-02-01

    The interaction of PLGA-chitosan Nanoplexes with ocular mucosa was investigated ex vivo and in vivo to assess their potential as ocular delivery system. Fluorescent Rhodamine Nanoplexes (Rd-Nanoplexes) were prepared by ionotropic gelation method. The size and morphology of Nanoplexes was investigated by TEM, SEM and PCS. The corneal retention, uptake and penetration of Nanoplexes were analyzed by spectrofluorimetry and confocal microscopy. Corneas from Rd-Nanoplexes-treated rabbits were evaluated for the in vivo uptake and ocular tolerance. The Nanoplexes prepared were round with a mean diameter of 115.6±17nm and the encapsulation efficiency of Rd was 59.4±2.5%. Data from ex vivo and in vivo studies showed that the amounts of Rd in the cornea were significantly higher for Nanoplexes than for a control Rd solution, these amounts being fairly constant for up to 24h. Confocal microscopy of the corneas revealed paracellular and transcellular uptake of the Nanoplexes. The uptake mechanism postulated was adsorptive-mediated endocytosis and opening of the tight junctions between epithelial cells. No alteration was microscopically observed after ocular surface exposure to Nanoplexes. Taken together, these data demonstrate that Nanoplexes are potentially useful as ocular drug carriers. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. OCT-based profiler for automating ocular surface prosthetic fitting (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Mujat, Mircea; Patel, Ankit H.; Maguluri, Gopi N.; Iftimia, Nicusor V.; Patel, Chirag; Agranat, Josh; Tomashevskaya, Olga; Bonte, Eugene; Ferguson, R. Daniel

    2016-03-01

    The use of a Prosthetic Replacement of the Ocular Surface Environment (PROSE) device is a revolutionary treatment for military patients that have lost their eyelids due to 3rd degree facial burns and for civilians who suffer from a host of corneal diseases. However, custom manual fitting is often a protracted painful, inexact process that requires multiple fitting sessions. Training for new practitioners is a long process. Automated methods to measure the complete corneal and scleral topology would provide a valuable tool for both clinicians and PROSE device manufacturers and would help streamline the fitting process. PSI has developed an ocular anterior-segment profiler based on Optical Coherence Tomography (OCT), which provides a 3D measure of the surface of the sclera and cornea. This device will provide topography data that will be used to expedite and improve the fabrication process for PROSE devices. OCT has been used to image portions of the cornea and sclera and to measure surface topology for smaller contact lenses [1-3]. However, current state-of-the-art anterior eye OCT systems can only scan about 16 mm of the eye's anterior surface, which is not sufficient for covering the sclera around the cornea. In addition, there is no systematic method for scanning and aligning/stitching the full scleral/corneal surface and commercial segmentation software is not optimized for the PROSE application. Although preliminary, our results demonstrate the capability of PSI's approach to generate accurate surface plots over relatively large areas of the eye, which is not currently possible with any other existing platform. Testing the technology on human volunteers is currently underway at Boston Foundation for Sight.

  19. Serotonin toxicity caused by moclobemide too soon after paroxetine-selegiline.

    PubMed

    Wu, Ming-Ling; Deng, Jou-Fang

    2009-08-01

    Serotonin toxicity is an iatrogenic complication of serotonergic drug therapy. It is due to an overstimulation of central and peripheral serotonin receptors that lead to neuromuscular, mental and autonomic changes. Moclobemide is a reversible inhibitor of monoamine oxidase (MAO)-A, selegiline is an irreversible selective inhibitor of MAO-B, and paroxetine is a selective serotonin reuptake inhibitor. Combined use of these agents is known to cause serotonin toxicity. A 53-year-old woman had been treated with paroxetine and selegiline. After moclobemide was prescribed in place of paroxetine without a washout period, she quickly developed confusion, agitation, ataxia, diaphoresis, tremor, mydriasis, ocular clonus, hyperreflexia, tachycardia, moderately elevated blood pressure and high fever, symptoms that were consistent with serotonin toxicity. Discontinuation of the drugs, hydration and supportive care were followed by remarkable improvement of baseline status within 3 days. This case demonstrates that serotonin toxicity may occur even with small doses of paroxetine, selegiline and moclobemide in combination. Physicians managing patients with depression must be aware of the potential for serotonin toxicity and should be able to recognize and treat or, ideally, anticipate and avoid this pharmacodynamically-mediated interaction that may occur between prescribed drugs.

  20. Prevalence of dry eye syndrome after allogeneic hematopoietic stem cell transplantation.

    PubMed

    Ivanir, Yair; Shimoni, Avichai; Ezra-Nimni, Orit; Barequet, Irina S

    2013-05-01

    To evaluate the prevalence, severity, and effect of dry eye in patients after allogeneic hematopoietic stem cell transplantation (aHSCT) and to correlate the findings to the duration after transplantation. A total of 222 eyes of 111 patients after aHSCT at the Department of Bone Marrow Transplantation, Sheba Medical Center, Israel in a consecutive 3-year period. All patients underwent a full ophthalmic examination and filled the ocular surface disease index (OSDI) questionnaire to assess ocular involvement in the form of dry eye syndrome or any other ocular manifestation. The main outcome measures were best-corrected visual acuity, tear break-up time, corneal fluorescein staining, Schirmer test, and OSDI questionnaire. A total of 111 patients were recruited. In 37%, a diagnosis of ocular graft versus host disease was previously made and 46% had no previous ocular examination. Schirmer test was less than 5 mm in 50% of all patients, and in 30% of patients with undiagnosed ocular involvement. The mean OSDI score was 13, and in 28% it was above 20. Correlation was found between visual acuity decrease and high OSDI score to the diagnosis of ocular graft versus host disease and signs of dry eye syndrome. A trend of worsening dry eye was observed up to the second half of the second year posttransplantation. Although many patients are either asymptomatic or do not seek ophthalmic examination, severe dry eye is a common finding after aHSCT. Mandatory follow-up, patient education, and early treatment may improve the quality of life.

  1. In vitro effects of preserved and unpreserved anti-allergic drugs on human corneal epithelial cells.

    PubMed

    Guzman-Aranguez, Ana; Calvo, Patricia; Ropero, Inés; Pintor, Jesús

    2014-11-01

    Treatment with topical eye drops for long-standing ocular diseases like allergy can induce detrimental side effects. The purpose of this study was to investigate in vitro cytotoxicity of commercially preserved and unpreserved anti-allergic eye drops on the viability and barrier function of monolayer and stratified human corneal-limbal epithelial cells. Cells were treated with unpreserved ketotifen solution, benzalkonium chloride (BAC)-containing anti-allergic drugs (ketotifen, olopatadine, levocabastine) as well as BAC alone. 3-(4,5-Dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay was used to determine cell viability. Effects of compounds on barrier function were analyzed measuring transepithelial electrical resistance (TEER) to determine paracellular permeability and rose bengal assays to evaluate transcellular barrier formation. The BAC-preserved anti-allergic formulations and BAC alone significantly reduced cell viability, monolayer cultures being more sensitive to damage by these solutions. Unpreserved ketotifen induced the least diminution in cell viability. The extent of decrease of cell viability was clearly dependent of BAC presence, but it was also affected by the different types of drugs when the concentration of BAC was low and the short time of exposure. Treatment with BAC-containing anti-allergic drugs and BAC alone resulted in increased paracellular permeability and loss of transcellular barrier function as indicated by TEER measurement and rose bengal assays. The presence of the preservative BAC in anti-allergic eye drop formulations contributes importantly to the cytotoxic effects induced by these compounds. Stratified cell cultures seem to be a more relevant model for toxicity evaluation induced on the ocular surface epithelia than monolayer cultures.

  2. Computed tear film and osmolarity dynamics on an eye-shaped domain

    PubMed Central

    Li, Longfei; Braun, Richard J.; Driscoll, Tobin A.; Henshaw, William D.; Banks, Jeffrey W.; King-Smith, P. Ewen

    2016-01-01

    The concentration of ions, or osmolarity, in the tear film is a key variable in understanding dry eye symptoms and disease. In this manuscript, we derive a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model includes the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. The governing system of coupled non-linear partial differential equations is solved using the Overture computational framework, together with a hybrid time-stepping scheme, using a variable step backward differentiation formula and a Runge–Kutta–Chebyshev method that were added to the framework. The results of our numerical simulations provide new insight into the osmolarity distribution over the ocular surface during the interblink. PMID:25883248

  3. Ocular injury with high-pressure paint: a case report.

    PubMed

    Bandyopadhyay, Chitrabhanu; Mitra, Arjit; Harrison, Rosalind J

    2009-01-01

    Chemical injury to the eye is an ophthalmic emergency that can be caused by a work-related accident or common household products. Uradil SZ261 G3Z-65 is a resin containing butyl gycol (2-butoxyethanol) and ethyl ethanol amine (2-dimethyaminoethanol). It is used in stoving enamels for interior and exterior use. The authors report a case of ocular surface injury with a highpressure industrial spray paint-Waterborne Stoving Gentian Blue containing Uradil.

  4. Safety parameters for avoiding acute ocular damage from the reflected CO2 (10.6 microns) laser beam.

    PubMed

    Friedman, N R; Saleeby, E R; Rubin, M G; Sandu, T; Krull, E A

    1987-11-01

    Reflections from instruments in the surgical field involving the CO2 laser beam present a serious ocular hazard. In addition to the use of plastic or glass protective eyewear, this hazard can be minimized by utilizing anodized instruments and recognizing the specific distances at which various reflections are no longer hazardous depending upon certain variables, including laser output wattage, emergent beam lengths, and surface characteristics of the reflecting instruments.

  5. [Light protection for xeroderma pigmentosum].

    PubMed

    Ettinger, M; Berneburg, M

    2017-05-01

    Xeroderma pigmentosum is a rare autosomal recessive disorder which is caused by germinal mutations responsible for the repair of ultraviolet (UV) radiation-induced DNA lesions. It is characterized by hypersensitivity to UV radiation, poikiloderma, ocular surface disease, and in some patients pronounced sunburn and neurological disease. Patients have a very high risk of developing ocular and skin cancer on exposed body sites. No cure is available for these patients except complete protection from all types of UV radiation.

  6. Clinical outcome in dogs with nasal tumors treated with intensity-modulated radiation therapy.

    PubMed

    Hunley, David W; Mauldin, G Neal; Shiomitsu, Keijiro; Mauldin, Glenna E

    2010-03-01

    Intensity-modulated radiation therapy (IMRT) is a valuable tool in human radiation oncology, but information on its use in veterinary medicine is lacking. In this study, 12 dogs with nasal tumors were treated with IMRT at a median radiation dose of 54 Gy. Patient survival times and frequency and severity of side effects on ocular structures, oral mucosa, and skin were recorded. Eight dogs (67%) had resolution of clinical signs during radiation therapy. Median overall survival time was 446 d with a 50% 1-year and a 25% 2-year survival rate. Minimal grade 2 or 3 acute skin toxicity, no grade 2 or 3 late skin toxicity, and no grade 2 or 3 toxicity to oral mucosa or the eye opposite the tumor were identified in the dogs treated with IMRT in this study. The ipsilateral eye could not be routinely spared due to its proximity to the tumor.

  7. Clinical outcome in dogs with nasal tumors treated with intensity-modulated radiation therapy

    PubMed Central

    Hunley, David W.; Mauldin, G. Neal; Shiomitsu, Keijiro; Mauldin, Glenna E.

    2010-01-01

    Intensity-modulated radiation therapy (IMRT) is a valuable tool in human radiation oncology, but information on its use in veterinary medicine is lacking. In this study, 12 dogs with nasal tumors were treated with IMRT at a median radiation dose of 54 Gy. Patient survival times and frequency and severity of side effects on ocular structures, oral mucosa, and skin were recorded. Eight dogs (67%) had resolution of clinical signs during radiation therapy. Median overall survival time was 446 d with a 50% 1-year and a 25% 2-year survival rate. Minimal grade 2 or 3 acute skin toxicity, no grade 2 or 3 late skin toxicity, and no grade 2 or 3 toxicity to oral mucosa or the eye opposite the tumor were identified in the dogs treated with IMRT in this study. The ipsilateral eye could not be routinely spared due to its proximity to the tumor. PMID:20514254

  8. Multimodal imaging of ocular surface of dry eye subjects

    NASA Astrophysics Data System (ADS)

    Zhang, Aizhong; Salahura, Gheorghe; Kottaiyan, Ranjini; Yoon, Geunyoung; Aquavella, James V.; Zavislan, James M.

    2016-03-01

    To study the relationship between the corneal lipid layer and the ocular surface temperature (OST), we conducted a clinical trial for 20 subjects. Subjects were clinically screened prior to the trial. Of the 20 subjects, 15 have Meibomian gland dysfunction (MGD), and 5 have aqueous-deficient dry eye (ADDE). A custom, circularly polarized illumination video tearscope measured the lipid layer thickness of the ocular tear film. A long-wave infrared video camera recorded the dynamic thermal properties of the ocular team film. The results of these two methods were analyzed and compared. Using principal component analysis (PCA) of the lipid layer distribution, we find that the 20 subjects could be categorized into five statistically significant groups, independent of their original clinical classification: thin (6 subjects), medium (5 subjects), medium and homogenous (3 subjects), thick (4 subjects), and very thick (2 subjects) lipids, respectively. We also conducted PCA of the OST data, and recategorized the subjects into two thermal groups by k-means clustering: one includes all ADDE subjects and some MGD subjects; the other includes the remaining MGD subjects. By comparing these two methods, we find that dry eye subjects with thin (<= 40 nm) lipids have significantly lower OST, and a larger OST drop range, potentially due to more evaporation. However, as long as the lipid layer is not thin (> 40 nm), there is no strong correlation between the lipid layer thickness and heterogeneity and the OST patterns.

  9. Toxic epidermal necrolysis: a paradigm of critical illness

    PubMed Central

    Estrella-Alonso, Alfonso; Aramburu, José Antonio; González-Ruiz, Mercedes Yolanda; Cachafeiro, Lucía; Sánchez, Manuel Sánchez; Lorente, José A.

    2017-01-01

    Toxic epidermal necrolysis is an adverse immunological skin reaction secondary in most cases to the administration of a drug. Toxic epidermal necrolysis, Stevens-Johnson syndrome, and multiform exudative erythema are part of the same disease spectrum. The mortality rate from toxic epidermal necrolysis is approximately 30%. The pathophysiology of toxic epidermal necrolysis is similar in many respects to that of superficial skin burns. Mucosal involvement of the ocular and genital epithelium is associated with serious sequelae if the condition is not treated early. It is generally accepted that patients with toxic epidermal necrolysis are better treated in burn units, which are experienced in the management of patients with extensive skin loss. Treatment includes support, elimination, and coverage with biosynthetic derivatives of the skin in affected areas, treatment of mucosal involvement, and specific immunosuppressive treatment. Of the treatments tested, only immunoglobulin G and cyclosporin A are currently used in most centers, even though there is no solid evidence to recommend any specific treatment. The particular aspects of the treatment of this disease include the prevention of sequelae related to the formation of synechiae, eye care to prevent serious sequelae that can lead to blindness, and specific immunosuppressive treatment. Better knowledge of the management principles of toxic epidermal necrolysis will lead to better disease management, higher survival rates, and lower prevalence of sequelae. PMID:29340540

  10. Hydrocortisone concentration influences time to clinically significant healing of acute inflammation of the ocular surface and adnexa - results from a double-blind randomized controlled trial.

    PubMed

    Sergiyenko, Nikolay; Sukhina, Ludmila; Bezdetko, Pavel; Kovalenko, Yuriy; Nikitin, Nikolai; Merzbacher, Matthias; Gross, Dorothea; Kohnen, Ralf

    2014-05-10

    The efficacy of topical ophthalmic corticosteroids depends upon small modifications in preparations, such as drug concentration.The aim of this study was to confirm that hydrocortisone acetate (HC-ac) ophthalmic ointments of 2.5% and 1% are more effective than a 0.5% eye ointment. In this randomized, double-blind, placebo-controlled, parallel-group clinical study, the change of signs and symptoms of acute inflammation of the ocular surface and adnexa was evaluated in 411 subjects. Median time to clinically relevant response as estimated by 50% reduction in clinical signs and symptoms (CSS) total score over the entire trial was similar for subjects treated with HC-ac 2.5% (73.5 h) and for subjects treated with HC-ac 1.0% (67.7 h) and was considerably and significantly longer for subjects treated with HC-ac 0.5% (111.8 h) [p < 0.001 for both dosages]. All trial medications were safe and well tolerated. Hydrocortisone acetate 2.5% and Hydrocortisone acetate 1% eye ointments are efficacious and safe treatments for acute inflammations of the ocular surface or adnexa, and showed significantly better efficacy than a control group treated with Hydrocortisone acetate 0.5% therapy. Current Controlled Trials ISRCTN15464650.

  11. Mechanisms Involved in Injury and Repair of the Murine Lacrimal Gland: Role of Programmed Cell Death and Mesenchymal Stem Cells

    PubMed Central

    Zoukhri, Driss

    2011-01-01

    The non-keratinized epithelia of the ocular surface are constantly challenged by environmental insults, such as smoke, dust, and airborne pathogens. Tears are the sole physical protective barrier for the ocular surface. Production of tears in inadequate quantity or of inadequate quality results in constant irritation of the ocular surface, leading to dry eye disease, also referred to as keratoconjunctivitis sicca (KCS). Inflammation of the lacrimal gland, such as occurs in Sjögren’s syndrome, sarcoidosis, chronic graft versus-host disease, and other pathological conditions, results in inadequate secretion of the aqueous layer of the tear film, and is a leading cause of dry eye disease. The hallmarks of lacrimal gland inflammation are the presence of immune cell infiltrates, loss of acinar epithelial cells (the secreting cells), and increased production of proinflammatory cytokines. To date, the mechanisms leading to acinar cell loss and the associated decline in lacrimal gland secretion are still poorly understood. It is also not understood why the remaining lacrimal gland cells are unable to proliferate in order to regenerate a functioning lacrimal gland. This article reviews recent advances in exocrine tissue injury and repair, with emphasis on the roles of programmed cell death and stem/progenitor cells. PMID:20427009

  12. Exploring the Predisposition of the Asian Eye to Development of Dry Eye.

    PubMed

    Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min

    2016-07-01

    To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all P<.05). A greater proportion of ASL and ADL participants exhibited incomplete blinking than CDL patients (all P<.05). There were no significant differences in tear film quality and dry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all P<.05). The CDL group displayed significantly greater anterior blepharitis and lid telangiectasia grades compared to both ASL and ADL groups (all P<.05). A higher degree of meibomian gland dropout and incomplete blinking was observed in both Asian groups compared to the Caucasian group, potentially predisposing these groups to dry eye. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Oral antioxidant therapy for marginal dry eye.

    PubMed

    Blades, K J; Patel, S; Aidoo, K E

    2001-07-01

    To assess the efficacy of an orally administered antioxidant dietary supplement for managing marginal dry eye. A prospective, randomised, placebo controlled trial with cross-over. Eye Clinic, Department of Vision Sciences, Glasgow Caledonian University. Forty marginal dry eye sufferers composed of 30 females and 10 males (median age 53 y; range 38-69 y). Baseline assessments were made of tear volume sufficiency (thread test), tear quality (stability), ocular surface status (conjunctival impression cytology) and dry eye symptoms (questionnaire). Each subject was administered courses of active treatment, placebo and no treatment, in random order for 1 month each and results compared to baseline. Tear stability and ocular surface status were significantly improved following active treatment (P<0.05). No changes from baseline were detected following administration of placebo and no treatment (P>0.05). Absolute increase in tear stability correlated with absolute change in goblet cell population density. Tear volume was not improved following any treatment period and dry eye symptom responses were subject to placebo effect. Oral antioxidants improved both tear stability and conjunctival health, although it is not yet understood whether increased ocular surface health mediates increased tear stability or vice versa. This study was supported by a PhD scholarship funded by the Department of Vision Sciences, Glasgow Caledonian University, Scotland. Antioxidant supplements and placebos were kindly donated by Vitabiotics.

  14. 4A syndrome: ocular surface investigation in an Italian young patient.

    PubMed

    Aragona, Pasquale; Rania, Laura; Roszkowska, Anna Maria; Puzzolo, Domenico; Micali, Antonio; Pisani, Antonina; Salzano, Giuseppina; Messina, Maria Francesca

    2014-12-08

    Allgrove's 4A syndrome determines ocular surface changes. This is the first report providing an up-to-dated analysis of the ocular surface in an affected patient. An 18-years-old male Caucasian patient, with a complex progressive gait disorder and adrenal insufficiency, was referred for ophthalmic evaluation, as part of the clinical assessment. He underwent the following tests: best corrected visual acuity, tear osmolarity, tear film break-up time (BUT), corneal fluorescein staining, Schirmer's I test, lid margin assessment, corneal sensitivity, in vivo corneal confocal microscopy, conjunctival impression cytology, tonometry and fundus exam. A dry eye condition was documented by the Schirmer's I test of 0 mm/5' in both eyes, accompanied by tear hyperosmolarity, mild meibomian gland dysfunction, reduced BUT, mucus filaments in the tear film and conjunctival epithelium metaplasic changes. The corneal confocal microscopy showed the presence of activated keratocytes, while the nerve pattern was normal. The dry eye in this patient appears to be due to tear aqueous deficiency and can be considered as part of the 4A syndrome. The decreased tear production, resulting from a deterioration of the autonomic innervation of the lacrimal glands rather than an impaired corneal innervation, can be considered as part of the systemic autonomic dysfunction present in this disease.

  15. Ocular surface inflammation, and nerve growth factor level in tears in active thyroid-associated ophthalmopathy.

    PubMed

    Yoon, Jin Sook; Choi, Soo Hyun; Lee, Joon H; Lee, Sung Jun; Lee, Sang Yeul

    2010-02-01

    To measure tear nerve growth factor (NGF) concentrations in cases of active thyroid-associated ophthalmopathy (TAO) before and after glucocorticoid treatment, and to correlate NGF levels with disease inflammatory activity and thyroid autoantibody concentration. The study involved 20 patients with active TAO and 20 age- and gender-matched controls. Tear break-up time (BUT) was obtained, the Schirmer test was performed, and tear NGF/total protein ratio was measured in control subjects and patients with active TAO before, and 2 and 4 weeks after, steroid treatment. Tear BUT and Schirmer values significantly increased after 2 and 4 weeks of steroid treatment (p < 0.001 and p = 0.004 respectively). Baseline tear NGF/total protein ratio was higher in patients with active TAO than in control subjects, and the ratio significantly decreased after 2 and 4 weeks of steroid treatment (p < 0.001). Tear NGF/total protein ratio did not correlate with inflammatory activity score, exophthalmos value and thyroid binding inhibiting immunoglobulin (TBII) level (p > 0.05). Tear NGF may have a specific role in ocular surface inflammation, which protects against ocular surface damage in patients with active TAO. Anti-inflammatory treatment significantly reduced the level of NGF in tears, increased tear film stability and production, and decreased congestive symptoms.

  16. Modified osteo-odonto keratoprosthesis--the Indian experience--results of the first 50 cases.

    PubMed

    Iyer, Geetha; Pillai, Vinay S; Srinivasan, Bhaskar; Falcinelli, Giovanni; Padmanabhan, Prema; Guruswami, Sitalakshmi; Falcinelli, Giancarlo

    2010-07-01

    To study the results of the modified osteo-odonto keratoprosthesis (MOOKP) surgery in bilateral end-stage ocular surface disorders. The MOOKP surgery is performed as a routine in 3 stages. Stage 1A involves removal of the iris and anterior vitrectomy with a corneal transplant if indicated. Stage 1B + 1C usually performed simultaneously involves harvesting the buccal mucosa and transplanting it onto the ocular surface along with fashioning of the osteo-odonto alveolar lamina. Stage 2 involves transplanting the osteo-odonto alveolar lamina to the eye 3 months later. The MOOKP surgery was completed in 50 eyes of 47 patients with a mean follow-up of 15.38 months (range: 1-54 months). Anatomic success was achieved in 96% of the eyes. Functional success of visual acuity > or = 20/60 was noted in 66% of eyes. Complications included oroantral fistula (6%), trophic mucosal alterations (8%), lamina exposure (central 6% and peripheral 8%), mucous membrane overgrowth (2%), hypotony (2%), expulsion of optic cylinder (4%), endophthalmitis (2%), glaucoma (20%), sterile vitritis (6%), and retinal detachment (2%). MOOKP is the keratoprosthesis of choice in bilateral end-stage ocular surface disorders in the Indian subcontinent. Complications do occur and have to be recognized and treated early.

  17. Therapeutic targets in dry eye syndrome.

    PubMed

    Peral, Assumpta; Domínguez-Godínez, Carmen O; Carracedo, Gonzalo; Pintor, Jesús

    2008-04-01

    Dry eye is a multifactorial disease of the tears and the ocular surface that manifests with a wide variety of signs and symptoms. It is prevalent in about 33% of the population worldwide. Due to the importance of the pathology, new tests, drugs and technologies have been developed to assist the diagnosis, management and follow-up of the disease. Current available therapies try to alleviate symptoms and to reduce signs in order to restore the ocular surface. Depending on the etiology of the pathology it is possible to use lubricants, secretagogues, biological tear substitutes or antiinflammatory drugs, either independently or combined. Nowadays, the therapies under clinical trial are devoted to stimulating tear components (e.g., diquafosol, a P2Y receptor agonist), or mucin secretion (e.g., rebamipide, an amino acid analogue of quinolinone). Others include gefarnate, a water-insoluble terpene fatty acid that contributes to restoring mucins on the ocular surface, or cevimeline, an oral cholinergic agonist that reduces the symptoms associated with dry eye. Other potential compounds described in patents are in a lower phase of drug development. These compounds come from different families of therapies, and among others, can be found in the form of steroidal and nonsteroidal antiinflammatory agents, vitamins A and D, neurotransmitters and neuropeptides. Copyright 2008 Prous Science, S.A.U. or its licensors. All rights reserved.

  18. Corneal Mechanical Thresholds Negatively Associate With Dry Eye and Ocular Pain Symptoms.

    PubMed

    Spierer, Oriel; Felix, Elizabeth R; McClellan, Allison L; Parel, Jean Marie; Gonzalez, Alex; Feuer, William J; Sarantopoulos, Constantine D; Levitt, Roy C; Ehrmann, Klaus; Galor, Anat

    2016-02-01

    To examine associations between corneal mechanical thresholds and metrics of dry eye. This was a cross-sectional study of individuals seen in the Miami Veterans Affairs eye clinic. The evaluation consisted of questionnaires regarding dry eye symptoms and ocular pain, corneal mechanical detection and pain thresholds, and a comprehensive ocular surface examination. The main outcome measures were correlations between corneal thresholds and signs and symptoms of dry eye and ocular pain. A total of 129 subjects participated in the study (mean age 64 ± 10 years). Mechanical detection and pain thresholds on the cornea correlated with age (Spearman's ρ = 0.26, 0.23, respectively; both P < 0.05), implying decreased corneal sensitivity with age. Dry eye symptom severity scores and Neuropathic Pain Symptom Inventory (modified for the eye) scores negatively correlated with corneal detection and pain thresholds (range, r = -0.13 to -0.27, P < 0.05 for values between -0.18 and -0.27), suggesting increased corneal sensitivity in those with more severe ocular complaints. Ocular signs, on the other hand, correlated poorly and nonsignificantly with mechanical detection and pain thresholds on the cornea. A multivariable linear regression model found that both posttraumatic stress disorder (PTSD) score (β = 0.21, SE = 0.03) and corneal pain threshold (β = -0.03, SE = 0.01) were significantly associated with self-reported evoked eye pain (pain to wind, light, temperature) and explained approximately 32% of measurement variability (R = 0.57). Mechanical detection and pain thresholds measured on the cornea are correlated with dry eye symptoms and ocular pain. This suggests hypersensitivity within the corneal somatosensory pathways in patients with greater dry eye and ocular pain complaints.

  19. Corneal Mechanical Thresholds Negatively Associate With Dry Eye and Ocular Pain Symptoms

    PubMed Central

    Spierer, Oriel; Felix, Elizabeth R.; McClellan, Allison L.; Parel, Jean Marie; Gonzalez, Alex; Feuer, William J.; Sarantopoulos, Constantine D.; Levitt, Roy C.; Ehrmann, Klaus; Galor, Anat

    2016-01-01

    Purpose To examine associations between corneal mechanical thresholds and metrics of dry eye. Methods This was a cross-sectional study of individuals seen in the Miami Veterans Affairs eye clinic. The evaluation consisted of questionnaires regarding dry eye symptoms and ocular pain, corneal mechanical detection and pain thresholds, and a comprehensive ocular surface examination. The main outcome measures were correlations between corneal thresholds and signs and symptoms of dry eye and ocular pain. Results A total of 129 subjects participated in the study (mean age 64 ± 10 years). Mechanical detection and pain thresholds on the cornea correlated with age (Spearman's ρ = 0.26, 0.23, respectively; both P < 0.05), implying decreased corneal sensitivity with age. Dry eye symptom severity scores and Neuropathic Pain Symptom Inventory (modified for the eye) scores negatively correlated with corneal detection and pain thresholds (range, r = −0.13 to −0.27, P < 0.05 for values between −0.18 and −0.27), suggesting increased corneal sensitivity in those with more severe ocular complaints. Ocular signs, on the other hand, correlated poorly and nonsignificantly with mechanical detection and pain thresholds on the cornea. A multivariable linear regression model found that both posttraumatic stress disorder (PTSD) score (β = 0.21, SE = 0.03) and corneal pain threshold (β = −0.03, SE = 0.01) were significantly associated with self-reported evoked eye pain (pain to wind, light, temperature) and explained approximately 32% of measurement variability (R = 0.57). Conclusions Mechanical detection and pain thresholds measured on the cornea are correlated with dry eye symptoms and ocular pain. This suggests hypersensitivity within the corneal somatosensory pathways in patients with greater dry eye and ocular pain complaints. PMID:26886896

  20. Toxic Hazards Research Unit - 1988

    DTIC Science & Technology

    1989-07-01

    and control groups, and all group means for these parameters were within the normal range for the age and species of test animals used (Wolford et al...13 APPENDIX 1 DRAIZEa SCALE FOR SCALING OCULAR LESIONS Parameter Score 1. Cornea A Opacity degree of density (area most taken for reading) No opacity...Therap 32 377 390 14 APPENDIX 2 DRAIZEa SCALE FOR EVALUATING AND SCORING SKIN REACTIONS Parameter Score 1. Erythema No erythema 0 Very slight erythema

  1. Mucoadhesive microparticles with a nanostructured surface for enhanced bioavailability of glaucoma drug.

    PubMed

    Park, Chun Gwon; Kim, Young Kook; Kim, Mi Jeung; Park, Min; Kim, Myung Hun; Lee, Seung Ho; Choi, Sung Yoon; Lee, Won Seok; Chung, You Jung; Jung, Young Eun; Park, Ki Ho; Choy, Young Bin

    2015-12-28

    Topical drug administration to the eye is limited by low drug bioavailability due to its rapid clearance from the preocular surface. Thus, multiple daily administrations are often needed, but patient compliance is low, hence a high chance of unsatisfactory treatment of ocular diseases. To resolve this, we propose mucoadhesive microparticles with a nanostructured surface as potential carriers for delivery of brimonidine, an ocular drug for glaucoma treatment. For sustained drug delivery, the microparticles were composed mainly of a diffusion-wall material, poly(lactic-co-glycolic acid) and a mucoadhesive polymer, polyethylene glycol, was used as an additive. Due to their nanostructured surface, the microparticles with a mucoadhesive material exhibited a 13-fold increase in specific surface area and could thus adhere better to the mucous layer on the eye, as compared with the conventional spherical microparticles. When loaded with brimonidine, the mucoadhesive microparticles with a nanostructured surface increased both drug bioavailability and its activity period by a factor of more than 2 over Alphagan P, a marketed eye drop of brimonidine. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Evaluation of tear evaporation from ocular surface by functional infrared thermography.

    PubMed

    Tan, Jen-Hong; Ng, E Y K; Acharya, U Rajendra

    2010-11-01

    A novel technique was developed to measure tear evaporation and monitor its variation with respect to time, for the studying of ocular physiology based on dynamic functional infrared thermography and the first law of thermodynamics using the measured ocular surface temperatures (OSTs). This is a noninvasive, noncontact temperature measuring method that is widely applied in the field of biomedicine. A simple method based on the ocular thermal data was proposed to measure the rate of tear evaporation. The OST of 60 normal subjects were recorded in the form of sequential thermal images. For each thermal sequence, the ocular region was selected and warped to a standard form. Thermal data within the regions were processed, on the basis of the first law of thermodynamics to derive the evaporation rate. For elder subjects (aged above 35), the rate was determined to be 55.82 Wm(-2) and for younger subjects, the rate was 58.9 Wm(-2). The corneal rate of evaporation in elder subjects was found statistically (p < 0.11) larger than their younger counterparts. The rate of blinking was observed to be related to the variation of evaporation rate. The authors have measured the evaporation rate on a sequence of thermographic images. A region of interest was selected at first and the same region on all the images were warped into a standard form. Calculations were performed based on the thermal data in those regions to obtain the values of interest. The authors found that the tear evaporation rate for subjects of all age groups was 57.36 +/- 12.73 Wm(-2) and the corneal tear evaporation was higher in elder subjects. The corneal rate of evaporation fluctuated in a larger magnitude in subjects who blinked more than average.

  3. Increased numbers of Demodex in contact lens wearers.

    PubMed

    Jalbert, Isabelle; Rejab, Shazana

    2015-06-01

    The aim of this study was to determine if Demodex infestation is more frequent in contact lens wearers than in nonwearers. Secondary aims were to evaluate the effects of Demodex on the ocular surface (symptoms and signs) and to evaluate the ability of confocal laser scanning microscopy to detect and quantify the Demodex infestation compared with the conventional light microscopic technique. Forty Asian female participants (20 nonwearers, 20 lens wearers) with a mean (± SD) age of 27 (± 9) years were recruited. Ocular comfort scores (Ocular Surface Disease Index, Ocular Comfort Index, and Dry Eye Questionnaire), vital staining (corneal, conjunctival, and lid wiper), tear osmolarity, tear breakup time, and meibomian gland evaluation were evaluated. Demodex was detected using in vivo confocal microscopy and conventional light microscopy. The number of Demodex was higher in lens wearers than in nonwearers (7.6 [± 5.8] vs. 5.0 [± 3.1]; p = 0.02). Demodex was observed in a large majority (90%) of lens wearers and in 65% of nonwearers using confocal microscopy (p = 0.06). The detection rate was lower in both groups using conventional light microscopy (p = 0.003) where Demodex could only be confirmed in 70% and 60% of lens wearers and nonwearers, respectively. The number of Demodex tended to increase with age (ρ = 0.28, p = 0.08), but Demodex did not appear to affect ocular comfort or any clinical signs (p > 0.05). Contact lens wearers harbor Demodex as frequently as nonwearers and in higher numbers, which is best detected using in vivo confocal microscopy. The significance of these findings is uncertain because no associations were found with any symptoms and signs of dry eye disease.

  4. Immunological impression cytology of the conjunctival epithelium in patients with thyroid orbitopathy-related dry eye.

    PubMed

    Hsu, S L; Lee, P Y; Chang, C H; Chen, C H

    2016-08-30

    Thyroid orbitopathy (TO) is an autoimmune disease that is complicated by ocular surface disorders, leading to discomfort. Dry eye is very prevalent in patients with TO. Recent studies on the pathogenesis of dry eye have focused on the inflammatory process, and some supporting evidence has been discovered. Because TO is a disorder of autoimmune origin, we assumed that the association between TO and dry eye is related to inflammation. Inflammation of the ocular surface in TO-related dry eye has not been well studied. In this study, we assessed cellular inflammation of the ocular surface and the cytokine profiles in patients with TO-related dry eye. Conjunctival impression cytology (CIC) was assessed with an immunofluorescent assay. TO-related dry eye was diagnosed by using the Schirmer test, tear break-up time, thyroid function, and clinical signs. CIC was combined with immunological staining of interleukin-1a (IL-1a), IL-1b, and IL- 6. The immunological impression cytology (IC) grade was compared to the clinical activity score of TO. All TO patients with dry eye were positive for IL-1a, IL-1b, and IL-6. However, the normal controls were also positive for IL-1a. A trend was observed between the clinical inflammatory score and immunological IC grade. This study was the first to delineate the immunological IC of TO-related dry eye. Our study aimed to investigate the pathogenesis of dry eye in TO. Our findings suggest that the conjunctival cytokines IL-1a, IL-1b, and IL-6 may play a role. The results of this study will be useful for future studies of additional inflammatory cytokines, and the levels of these cytokines could be used as an outcome to assess the efficacy of treatment, such as anti-cytokine or immunosuppression therapy, in patients with TO-related dry eye or other ocular surface inflammatory disorders.

  5. Effects of silicone hydrogel contact lens wear on ocular surface sensitivity to tactile, pneumatic mechanical, and chemical stimulation.

    PubMed

    Situ, Ping; Simpson, Trefford L; Jones, Lyndon W; Fonn, Desmond

    2010-12-01

    To determine the effects of silicone hydrogel lens wear and lens-solution interactions on ocular surface sensitivity. Forty-eight adapted lens wearers completed the study, which comprised two phases. Phase 1 included habitual lens wear, no lens wear (7 ± 3 days), and balafilcon A lenses (PV; PureVision; Bausch & Lomb, Rochester, NY) with a hydrogen peroxide-based regimen for 2 weeks; phase 2 included wear of PV with the use of a multipurpose solution containing either polyhexamethylene-biguanide (PHMB) or Polyquad/Aldox (Alcon Laboratories, Fort Worth, TX) preservative, each for 1 week, with a 2-week washout period between solutions. Tactile and pneumatic (mechanical and chemical) stimuli were delivered, and thresholds were determined by Cochet-Bonnet (Luneau Ophthalmologie, Chartres, France) and Belmonte (Cooperative Research Centre for Eye Research and Technology, Sydney, NSW, Australia) pneumatic esthesiometers, respectively. Corneal and conjunctival thresholds and staining scores were assessed at baseline, after 2 and 8 hours of lens wear on day 1 and at the end of each wearing cycle (2 hours). In phase 1, compared to the no-lens baseline, corneal tactile thresholds increased at the 1-day, 8-hour and the 2-week visits (P < 0.05), whereas conjunctival mechanical thresholds decreased at the 1-day, 2-hour and the 2-week visits (P < 0.05). In phase 2, the chemical thresholds were lower with PHMB-preserved solution compared with the Polyquad/Aldox system at the 1-day, 2-hour and the 1-week visits (P < 0.05). Staining scores correlated inversely with conjunctival chemical thresholds (all P < 0.05). Ocular surface sensitivity changed in adapted lens wearers, when lenses were refit after a no-lens interval and during lens wear with different care regimens. The corneal staining that was observed with certain lens-solution combinations was accompanied by sensory alteration of the ocular surface-that is, higher levels of staining correlated with increased conjunctival chemical sensitivity. (ClinicalTrials.gov number, NCT00455455.).

  6. Analysis of Cytokine Levels in Tears and Clinical Correlations After Intense Pulsed Light Treating Meibomian Gland Dysfunction.

    PubMed

    Liu, Ruixing; Rong, Bei; Tu, Ping; Tang, Yun; Song, Wenjing; Toyos, Rolando; Toyos, Melissa; Yan, Xiaoming

    2017-11-01

    To investigate the change from baseline of inflammatory markers in tears of dry eye disease (DED) subjects owing to meibomian gland dysfunction (MGD) after intense pulsed light (IPL) treatment and meibomian gland expression (MGE) compared to sham treatment, and the correlations with ocular surface parameters. Randomized, double-masked, controlled study. Those randomized into the active treatment arm received 3 consecutive treatments (14∼16 J/cm 2 ) approximately 4 weeks apart in the periocular region. Control eyes received 3 treatments in the same intervals of 0 J/cm 2 . Tear samples in all eyes were collected and analyzed at baseline, week 12, and/or week 4 for interleukin (IL)-17A, IL-6, and prostaglandin E2 (PGE2). The correlations between cytokines and ocular surface parameters were analyzed before and after IPL treatment. All of the inflammatory markers declined in value compared to baselines. IL-17A and IL-6 showed statistically significant decreases compared to sham treatment at each measured time point. PGE2 showed statistically significant decreases compared to sham at week 12. Results showed that the expressions of IL-17A and IL-6 correlated well with ocular surface parameters of the lower eyelid before IPL. The changed values of IL-6 and PGE2 in tears correlated with the changed values of partial ocular surface parameters after IPL treatment in study eyes, respectively. The study results suggest that IPL can significantly reduce inflammatory markers in tears of patients suffering with DED owing to MGD after IPL treatment. These findings indicate that IL-17A and IL-6 play roles in the pathogenesis of DED owing to MGD, and the reduction of the inflammatory factors is consistent with the improvement of partial clinical symptoms and signs. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Microbial Contamination of Contact Lenses, Lens Care Solutions, and Their Accessories: A Literature Review

    PubMed Central

    Szczotka-Flynn, Loretta B.; Pearlman, Eric; Ghannoum, Mahmoud

    2012-01-01

    Purpose A contact lens (CL) can act as a vector for microorganisms to adhere to and transfer to the ocular surface. Commensal microorganisms that uneventfully cohabitate on lid margins and conjunctivae and potential pathogens that are found transiently on the ocular surface can inoculate CLs in vivo. In the presence of reduced tissue resistance, these resident microorganisms or transient pathogens can invade and colonize the cornea or conjunctiva to produce inflammation or infection. Methods The literature was reviewed and used to summarize the findings over the last 30 years on the identification, enumeration, and classification of microorganisms adherent to CLs and their accessories during the course of normal wear and to hypothesize the role that these microorganisms play in CL infection and inflammation. Results Lens handling greatly increases the incidence of lens contamination, and the ocular surface has a tremendous ability to destroy organisms. However, even when removed aseptically from the eye, more than half of lenses are found to harbor microorganisms, almost exclusively bacteria. Coagulase-negative Staphylococci are most commonly cultured from worn lenses; however, approximately 10% of lenses harbor Gram-negative and highly pathogenic species, even in asymptomatic subjects. In storage cases, the incidence of positive microbial bioburden is also typically greater than 50%. All types of care solutions can become contaminated, including up to 30% of preserved products. Conclusions The process of CL-related microbial keratitis and inflammation is thought to be preceded by the presence or transfer or both of microorganisms from the lens to the ocular surface. Thus, this detailed understanding of lens-related bioburden is important in the understanding of factors associated with infectious and inflammatory complications. Promising mechanisms to prevent bacterial colonization on lenses and lens cases are forthcoming, which may decrease the incidence of microbially driven CL complications. PMID:20168237

  8. Release of complement regulatory proteins from ocular surface cells in infections.

    PubMed

    Cocuzzi, E; Guidubaldi, J; Bardenstein, D S; Chen, R; Jacobs, M R; Medof, E M

    2000-11-01

    The decay accelerating factor (DAF or CD55) and the membrane inhibitor of reactive lysis (MIRL or CD59), two complement regulatory proteins that protect self cells from autologous complement-mediated injury, are attached to corneal and cqonjunctival epithelial cells by glycosylphos-phatidylinositol (GPI) anchors. We sought to 1) determine the frequency with which bacteria recovered from patients with infections of the eye elaborate factors that can remove these surface proteins from ocular cells, 2) determine the spectrum of bacteria from other sites that have similar effects, and 3) establish the time interval required for reconstitution of the two regulators. Culture supernatants of 18 ocular isolates [P. aeruginosa (n = 3), S. marcescens (n = 1), S. epidermidis (n = 9), and S. aureus (n = 5)], and > 100 other clinical specimens isolated in the hospital's microbiology laboratory [P. mirabilis (n = 1), S. aureus (n = 65), S. epidermidis (n = 24), B. cereus (n = 12), H. influenzae (n = 15), and Enterobacter sp. (n = 21)] were incubated at 37 degrees C for various times with conjunctival epithelial cells, conjunctival fibroblasts or HeLa cells and the release of DAF and CD59 proteins from the surfaces of the cells analyzed by 2-site immunoradiometric assays and by Western blotting. The kinetics of recovery of DAF and CD59 expression on the cells was measured by flow cytometry. DAF and/or CD59 release from the cell monolayers varied from < 5% to > 99% at as much as a 1:81 dilution of the supernatant from some bacteria. On conjunctival epithelial cells, more than 8 hr was required for 44% recovery of DAF expression and for 50% recovery of CD59 expression. Bacteria produce phospholipases and/or other enzymes which can efficiently remove DAF and CD59 from ocular cell surfaces. This phenomenon may correlate with their in vivo pathogenicity.

  9. Neurturin-deficient mice develop dry eye and keratoconjunctivitis sicca.

    PubMed

    Song, Xiu Jun; Li, De-Quan; Farley, William; Luo, Li Hui; Heuckeroth, Robert O; Milbrandt, Jeffrey; Pflugfelder, Stephen C

    2003-10-01

    Neurturin has been identified as a neurotrophic factor for parasympathetic neurons. Neurturin-deficient (NRTN(-/-)) mice have defective parasympathetic innervation of their lacrimal glands. This study was conducted to evaluate tear function and ocular surface phenotype in NRTN(-/-) mice. Determined by tail genomic DNA PCR, 25 NRTN(-/-) mice and 17 neurturin-normal (NRTN(+/+)) mice aged 6 weeks to 4 months were evaluated. Aqueous tear production, tear fluorescein clearance and corneal sensation were serially measured. Corneal permeability to AlexaFluor dextran (AFD; Molecular Probes, Eugene, OR) was measured by a fluorometric assay at 485 nm excitation and 530 nm emission. Histology was evaluated in PAS-stained sections. Mucin and HLA class II (IA) antigen were assessed by immunofluorescent staining. Tear IL-1beta was measured by ELISA, and tear matrix metalloproteinase (MMP)-9 by zymography. Gene expression in the corneal epithelia was analyzed by semiquantitative RT-PCR. In comparison to that in age-matched NRTN(+/+) mice, aqueous tear production, tear fluorescein clearance, and corneal sensation were significantly reduced in NRTN(-/-) mice, whereas corneal permeability to AFD was significantly increased. Immunoreactive MUC-4 and -5AC mucin and goblet cell density (P < 0.001) in the conjunctiva of NRTN(-/-) mice were lower than in NRTN(+/+) mice. The expression of MUC-1 and -4 mRNA by the corneal epithelium was reduced in NRTN(-/-) mice. There were a significantly greater number of IA antigen-positive conjunctival epithelial cells in NRTN(-/-) mice than NRTN(+/+) mice. Tear fluid IL-1beta and MMP-9 concentrations and the expression of IL-1beta, TNF-alpha, macrophage inflammatory protein (MIP)-2, cytokine-induced neutrophil chemoattractant (KC), and MMP-9 mRNA by the corneal epithelia were significantly increased in NRTN(-/-) mice, compared with NRTN(+/+) mice. Neurturin-deficient mice show phenotypic changes and ocular surface inflammation that mimic human keratoconjunctivitis sicca. This model supports the importance of a functional ocular surface-central nervous system-lacrimal gland sensory-autonomic neural network in maintaining ocular surface health and homeostasis.

  10. Effects of Prolonged Reading on Dry Eye.

    PubMed

    Karakus, Sezen; Agrawal, Devika; Hindman, Holly B; Henrich, Claudia; Ramulu, Pradeep Y; Akpek, Esen K

    2018-04-25

    To demonstrate the effects of prolonged silent reading on tear film and ocular surface parameters. Prospective, observational clinical study. A total of 177 patients with dry eye and 34 normal controls aged 50 years and older. After evaluating symptoms using the Ocular Surface Disease Index (OSDI) questionnaire, the following tests were performed in consecutive order: automated noninvasive tear break-up time (TBUT), surface asymmetry and regularity indices, Schirmer's testing without anesthesia, corneal staining using fluorescein, and conjunctival staining using lissamine green. The participants were then asked to read a 30-minute validated passage silently. The tests were repeated after the reading task. Changes in tear film and ocular surface parameters after reading. All parameters, with the exception of surface asymmetry index, worsened after the reading task in patients with dry eye and in controls. The worsening reached a statistical significance for corneal and conjunctival staining in the dry eye group (P < 0.001) and for corneal staining in the control group (P < 0.01). At baseline, OSDI scores correlated only with corneal and conjunctival staining scores (r = 0.19, P = 0.006 and r = 0.27, P < 0.001). Among postreading measurements, baseline OSDI scores correlated with TBUT (r = -0.15, P = 0.03) in addition to corneal and conjunctival staining (r = 0.25, P < 0.001 and r = 0.22, P = 0.001). Changes in TBUT and Schirmer's test correlated significantly with their respective baseline values (r = -0.61, P < 0.001 and r = -0.44, P < 0.001), indicating that the more unstable the tear film and the lower the aqueous tear secretion, the worse they became after the prolonged reading task. Worsening in corneal staining directly correlated with the baseline conjunctival staining (r = 0.17, P = 0.02) and surface regularity index (r = 0.21, P = 0.01). Evaluating tear film and ocular surface parameters at rest may miss clinical findings brought about by common everyday tasks such as reading, leading to discordance between patient-reported symptoms and clinician-observed signs. Quantifying dry eye after visually straining activities such as prolonged silent reading may help better understand patient symptomatology. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. Mucin characteristics of human corneal-limbal epithelial cells that exclude the rose bengal anionic dye.

    PubMed

    Argüeso, Pablo; Tisdale, Ann; Spurr-Michaud, Sandra; Sumiyoshi, Mika; Gipson, Ilene K

    2006-01-01

    Rose bengal is an organic anionic dye used to assess damage of the ocular surface epithelium in ocular surface disease. It has been proposed that mucins have a protective role, preventing rose bengal staining of normal ocular surface epithelial cells. The current study was undertaken to evaluate rose bengal staining in a human corneal-limbal epithelial (HCLE) cell line known to produce and glycosylate membrane-associated mucins. HCLE cells were grown to confluence in serum-free medium and switched to DMEM/F12 with 10% serum to promote differentiation. Immunolocalization of the membrane-associated mucins MUC1 and MUC16 and the T-antigen carbohydrate epitope was performed with the monoclonal antibodies HMFG-2 and OC125 and jacalin lectin, respectively. To assess dye uptake, cultures were incubated for 5 minutes with 0.1% rose bengal and photographed. To determine whether exclusion of negatively charged rose bengal requires a negative charge at the cell surface, cells were incubated with fluoresceinated cationized ferritin. The effect of hyperosmotic stress on rose bengal staining in vitro was evaluated by increasing the ion concentration (Ca+2 and Mg+2) in the rose bengal uptake assay. The cytoplasm and nucleus of confluent HCLE cells cultured in media without serum, lacking the expression of MUC16 but not MUC1, as well as human corneal fibroblasts, which do not express mucins, stained with rose bengal. Culture of HCLE cells in medium containing serum resulted in the formation of islands of stratified cells that excluded rose bengal. Apical cells of the stratified islands produced MUC16 and the T-antigen carbohydrate epitope on their apical surfaces. Colocalization experiments demonstrated that fluoresceinated cationized ferritin did not bind to these stratified cells, indicating that rose bengal is excluded from cells that lack negative charges. Increasing the amounts of divalent cations in the media reduced the cellular area protected against rose bengal uptake. These results indicate that stratification and differentiation of corneal epithelial cells, as measured by the capacity to produce the membrane-associated mucin MUC16 and the mucin-associated T-antigen carbohydrate on their apical surfaces provide protection against rose bengal penetrance in vitro and suggest a role for membrane-associated mucins and their oligosaccharides in the protection of ocular surface epithelia.

  12. Mucin Characteristics of Human Corneal-Limbal Epithelial Cells that Exclude the Rose Bengal Anionic Dye

    PubMed Central

    Argüeso, Pablo; Tisdale, Ann; Spurr-Michaud, Sandra; Sumiyoshi, Mika; Gipson, Ilene K.

    2005-01-01

    Purpose Rose bengal is an organic anionic dye used to assess damage of the ocular surface epithelium in ocular surface disease. It has been proposed that mucins have a protective role, preventing rose bengal staining of normal ocular surface epithelial cells. The current study was undertaken to evaluate rose bengal staining in a human corneal-limbal epithelial (HCLE) cell line known to produce and glycosylate membrane-associated mucins. Methods HCLE cells were grown to confluence in serum-free medium and switched to DMEM/F12 with 10% serum to promote differentiation. Immunolocalization of the membrane-associated mucins MUC1 and MUC16 and the T-antigen carbohydrate epitope was performed with the monoclonal antibodies HMFG-2 and OC125 and jacalin lectin, respectively. To assess dye uptake, cultures were incubated for 5 minutes with 0.1% rose bengal and photographed. To determine whether exclusion of negatively charged rose bengal requires a negative charge at the cell surface, cells were incubated with fluoresceinated cationized ferritin. The effect of hyperosmotic stress on rose bengal staining in vitro was evaluated by increasing the ion concentration (Ca+2 and Mg+2) in the rose bengal uptake assay. Results The cytoplasm and nucleus of confluent HCLE cells cultured in media without serum, lacking the expression of MUC16 but not MUC1, as well as human corneal fibroblasts, which do not express mucins, stained with rose bengal. Culture of HCLE cells in medium containing serum resulted in the formation of islands of stratified cells that excluded rose bengal. Apical cells of the stratified islands produced MUC16 and the T-antigen carbohydrate epitope on their apical surfaces. Colocalization experiments demonstrated that fluoresceinated cationized ferritin did not bind to these stratified cells, indicating that rose bengal is excluded from cells that lack negative charges. Increasing the amounts of divalent cations in the media reduced the cellular area protected against rose bengal uptake. Conclusions These results indicate that stratification and differentiation of corneal epithelial cells, as measured by the capacity to produce the membrane-associated mucin MUC16 and the mucin-associated T-antigen carbohydrate on their apical surfaces provide protection against rose bengal penetrance in vitro and suggest a role for membrane-associated mucins and their oligosaccharides in the protection of ocular surface epithelia. PMID:16384952

  13. The effects of 2 week senofilcon-A silicone hydrogel contact lens daily wear on tear functions and ocular surface health status.

    PubMed

    Dogru, Murat; Ward, Samantha K; Wakamatsu, Tais; Ibrahim, Osama; Schnider, Cristina; Kojima, Takashi; Matsumoto, Yukihiro; Ogawa, Junko; Shimazaki, Jun; Tsubota, Kazuo

    2011-04-01

    To prospectively investigate the effects of 2 week senofilcon A contact lens (CL) daily wear on the functional visual acuity (VA), ocular surface and tear film. Seventeen right eyes of 17 senofilcon A CL wearers without any ocular or systemic diseases were examined before and 2 weeks after lens wear. Visual acuity measurements, tear evaporation rate, ELISA for tear cytokines, strip meniscometry, tear lipid layer interferometry, tear film break-up time (BUT), in vivo confocal microscopy, corneal sensitivity, ocular surface vital staining, Schirmer I test and brush cytology for MUC5AC mRNA expression were performed before and after CL wear. The best corrected Landolt VA, functional VA parameters, the mean lipid layer interferometry grades, tear evaporation rates, Schirmer test values, vital staining scores and in vivo confocal microscopy parameters did not show any significant differences after 2 weeks of CL wear. The tear film BUT showed a significant decrease together with a significant down regulation of MUC5 AC mRNA expression after CL wear. A statistically significant elevation in the mean tear interleukin (IL)-6 concentration was also observed after 2 weeks of CL wear. Two week senofilcon A daily CL wear seems to be associated with tear instability, a decrease in MUC5AC expression, and elevation of IL-6 in tears without significant alterations in epithelial damage scores or in the morphology or density of in vivo keratoconjunctival cells and nerves. Alterations associated with long term wear and patients with dry eye disease need to be studied in future trials. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Frequency and risk factors associated with dry eye in patients attending a tertiary care ophthalmology center in Mexico City

    PubMed Central

    Martinez, Jaime D; Galor, Anat; Ramos-Betancourt, Nallely; Lisker-Cervantes, Andrés; Beltrán, Francisco; Ozorno-Zárate, Jorge; Sánchez-Huerta, Valeria; Torres-Vera, Marco-Antonio; Hernández-Quintela, Everardo

    2016-01-01

    Purpose The purpose of this study was to ascertain the frequency and risk factors of dry eye (DE) among patients attending a tertiary care ophthalmology center in Mexico. Methods Approximately 338 consecutive new patients attending a tertiary care ophthalmology center in Mexico City underwent an ocular surface examination, which included tear film break-up time, fluorescein corneal staining, Schirmer’s test, and evaluation of meibum quality. Symptoms of DE were evaluated by the Ocular Surface Disease Index and Dry Eye Questionnaire-5. Information on demographics, exposures, past medical and ocular history, and medications was also collected. Results The frequency of severe DE symptoms was found to be 43% based on the Ocular Surface Disease Index and 30% based on Dry Eye Questionnaire-5. Risk factors significantly associated with increased DE symptoms included dry mouth and gastrointestinal ulcer medications. With regard to signs, aqueous tear deficiency was a less-frequent finding (22%) in our population than evaporative deficiency (94%). Risk factors associated with aqueous tear deficiency were dry mouth and diuretic use. No risk factors were associated with evaporative deficiency. Risk factors associated with meibomian gland dysfunction included old age, male sex, arthritis, and use of an antihypertensive. The only risk factor associated with corneal staining was dry mouth. Conclusion This is the first study to demonstrate the frequency of symptomatic and clinical DE in a tertiary care ophthalmology center in Mexico. The frequency of DE ranged from 30% using a symptomatic definition to 94% using objective measures. Different risk factors were found for different aspects of DE, suggesting differing underlying pathophysiologies behind different DE subtypes. PMID:27499613

  15. Can We Improve the Tolerance of an Ocular Prosthesis by Enhancing Its Surface Finish?

    PubMed

    Litwin, Andre S; Worrell, Emma; Roos, Jonathan C P; Edwards, Barry; Malhotra, Raman

    Patients who wear an ocular prosthesis frequently suffer with dry eye symptoms and socket discharge, often on a daily basis. The aim of the study was to determine whether a smoother, optical quality polish of the prosthesis' surface could improve symptoms and wear tolerance. The study was designed as single-center, single-masked, prospective randomized controlled trial. Eighty-eight consecutive patients undergoing annual ocular prosthesis maintenance review were approached from the prosthesis clinic. Forty-one out of 49 eligible patients were recruited. Participants were randomized to either a standard or a higher "optical quality" polish of their prosthesis. At entry to the trial, at 1 month, and 12 months they completed a questionnaire covering cleaning, lubricant use, inflammation, discomfort, and discharge. Lower scores indicated better tolerance of the prosthesis. At each visit, the prosthesis was stained and photographed against a standard background to assess deposit build up. Primary outcome measures were 1) a subjective questionnaire score and 2) an objective assessment of surface deposit build-up on prosthetic eyes by standardized photographic grading. Forty-one patients participated in the study. The median age of their prosthesis was 36 months (range 9 months-40 years). There was no statistically significant difference in questionnaire scores or deposit build up between the 2 groups at baseline. By 12-months, the higher optical quality polish showed a statistically significant reduction in symptoms and frequency of discharge (2.19 vs. 3.85; p = 0.05-lower scores better). Scoring of the prosthesis' deposit build-up showed a significant difference at 1 month, but this was not sustained at 12 months. Creating an optical quality finish to an ocular prosthesis reduces deposit build up on artificial eyes. The authors found this modification improved patient tolerance at 12 months.

  16. Therapeutic potential of trichostatin A to control inflammatory and fibrogenic disorders of the ocular surface.

    PubMed

    Kitano, Ai; Okada, Yuka; Yamanka, Osamu; Shirai, Kumi; Mohan, Rajiv R; Saika, Shizuya

    2010-12-31

    To examine the effects of a histone deacetylase inhibitor, Trichostatin A (TSA), on the behavior of macrophages and subconjunctival fibroblasts in vitro and on ocular surface inflammation and scarring in vivo using an alkali burn wound healing model. Effects of TSA on expression of inflammation-related growth factors or collagen I were examined by real-time RT-PCR or immunoassay in mouse macrophages or human subconjunctival fibroblasts. Effects of TSA on trans forming growth factor β (TGFβ)/Smad signaling were evaluated with western blotting and/or immunocytochemistry. Alkali-burn injuries on the eyes of mice were performed with three µl of 0.5 N NaOH under general and topical anesthesia. TSA (600 µg/Kg daily) or vehicle was administered to animals via intraperitoneal (i.p.) injection. Histology and real-time RT-PCR investigations evaluated the effects of TSA on the healing process of the cornea. TSA inhibited TGFβ 1 and vascular endothelial growth factor (VEGF) expression in macrophages, and TGFβ1 and collagen I in ocular fibroblasts. It elevated the expression of 5'-TG-3'-interacting factor (TGIF) and Smad7 in fibroblasts and blocked nuclear translocation of phospho-Smad2. Real-time PCR and immunocytochemistry studies showed that systemic administration of TSA suppressed the inflammation and fibrotic response in the stroma and accelerated epithelial healing in the alkali-burned mouse cornea. Systemic administration of TSA reduces inflammatory and fibrotic responses in the alkali-burned mouse ocular surface in vivo. The mechanisms of action involve attenuation of Smad signal in mesenchymal cells and reduction in the activation and recruitment of macrophages. TSA has the potential to treat corneal scarring in vivo.

  17. Chemokine receptors CCR6 and CXCR3 are necessary for CD4(+) T cell mediated ocular surface disease in experimental dry eye disease.

    PubMed

    Coursey, Terry G; Gandhi, Niral B; Volpe, Eugene A; Pflugfelder, Stephen C; de Paiva, Cintia S

    2013-01-01

    CD4(+) T cells are essential to pathogenesis of ocular surface disease in dry eye. Two subtypes of CD4(+) T cells, Th1 and Th17 cells, function concurrently in dry eye to mediate disease. This occurs in spite of the cross-regulation of IFN-γ and IL-17A, the prototypical cytokines Th1 and Th17 cells, respectively. Essential to an effective immune response are chemokines that direct and summon lymphocytes to specific tissues. T cell trafficking has been extensively studied in other models, but this is the first study to examine the role of chemokine receptors in ocular immune responses. Here, we demonstrate that the chemokine receptors, CCR6 and CXCR3, which are expressed on Th17 and Th1 cells, respectively, are required for the pathogenesis of dry eye disease, as CCR6KO and CXCR3KO mice do not develop disease under desiccating stress. CD4(+) T cells from CCR6KO and CXCR3KO mice exposed to desiccating stress (DS) do not migrate to the ocular surface, but remain in the superficial cervical lymph nodes. In agreement with this, CD4(+) T cells from CCR6 and CXCR3 deficient donors exposed to DS, when adoptively transferred to T cell deficient recipients manifest minimal signs of dry eye disease, including significantly less T cell infiltration, goblet cell loss, and expression of inflammatory cytokine and matrix metalloproteinase expression compared to wild-type donors. These findings highlight the important interaction of chemokine receptors on T cells and chemokine ligand expression on epithelial cells of the cornea and conjunctiva in dry eye pathogenesis and reveal potential new therapeutic targets for dry eye disease.

  18. Chemokine Receptors CCR6 and CXCR3 Are Necessary for CD4+ T Cell Mediated Ocular Surface Disease in Experimental Dry Eye Disease

    PubMed Central

    Coursey, Terry G.; Gandhi, Niral B.; Volpe, Eugene A.; Pflugfelder, Stephen C.; de Paiva, Cintia S.

    2013-01-01

    CD4+ T cells are essential to pathogenesis of ocular surface disease in dry eye. Two subtypes of CD4+ T cells, Th1 and Th17 cells, function concurrently in dry eye to mediate disease. This occurs in spite of the cross-regulation of IFN-γ and IL-17A, the prototypical cytokines Th1 and Th17 cells, respectively. Essential to an effective immune response are chemokines that direct and summon lymphocytes to specific tissues. T cell trafficking has been extensively studied in other models, but this is the first study to examine the role of chemokine receptors in ocular immune responses. Here, we demonstrate that the chemokine receptors, CCR6 and CXCR3, which are expressed on Th17 and Th1 cells, respectively, are required for the pathogenesis of dry eye disease, as CCR6KO and CXCR3KO mice do not develop disease under desiccating stress. CD4+ T cells from CCR6KO and CXCR3KO mice exposed to desiccating stress (DS) do not migrate to the ocular surface, but remain in the superficial cervical lymph nodes. In agreement with this, CD4+ T cells from CCR6 and CXCR3 deficient donors exposed to DS, when adoptively transferred to T cell deficient recipients manifest minimal signs of dry eye disease, including significantly less T cell infiltration, goblet cell loss, and expression of inflammatory cytokine and matrix metalloproteinase expression compared to wild-type donors. These findings highlight the important interaction of chemokine receptors on T cells and chemokine ligand expression on epithelial cells of the cornea and conjunctiva in dry eye pathogenesis and reveal potential new therapeutic targets for dry eye disease. PMID:24223818

  19. Long-term effect of BAK-free travoprost on ocular surface and intraocular pressure in glaucoma patients after transition from latanoprost.

    PubMed

    Aihara, Makoto; Otani, Shin-ichiro; Kozaki, Jun; Unoki, Kazuhiko; Takeuchi, Masamitsu; Minami, Keiichiro; Miyata, Kazunori

    2012-01-01

    To assess the efficacy and tolerability of benzalkonium chloride (BAK)-free travoprost after transition from BAK-preserved latanoprost. This was a prospective, open-label, multicenter study in patients with open-angle glaucoma or ocular hypertension who had been treated with latanoprost monotherapy for at least 3 months. The main outcome measures were superficial punctate keratopathy (SPK), hyperemia, and intraocular pressure (IOP). At baseline, 1, 3, and 12 months, hyperemia, SPK, and IOP were consecutively assessed. Hyperemia was assessed using a 4-grade scale. SPK was assessed by fluorescence staining observed by Area-Density classification. The IOP was measured by Goldmann applanation tonometry. One hundred and fourteen patients participated in this study. Twenty-eight patients discontinued medications by 1 month. Sixty-seven patients completed the study. Transition from latanoprost to BAK-free travoprost showed no significant effect on hyperemia at 1 month, but showed significant decreases at 3 and 12 months compared with baseline (P<0.05). The prevalence of SPK, especially its severity score, at all points were significantly reduced compared with baseline (P<0.05). The IOP at baseline and at 12 months after transition was 14.9±3.4 and 14.3±3.3 mm Hg, indicating a significant reduction after the change in regimen compared with baseline (P<0.05). Treatment for 12 months with BAK-free travoprost after BAK-preserved latanoprost resulted in fewer ocular surface complications, as indicated by the reduced prevalence of SPK and decreased hyperemia, and no clinically relevant changes in IOP. BAK-free travoprost may have beneficial effects on the ocular surface while showing IOP-lowering efficacy comparable with BAK-preserved eye drops.

  20. Evaluation of lipid oxidative stress status and inflammation in atopic ocular surface disease

    PubMed Central

    Wakamatsu, Tais H.; Ayako, Igarashi; Takano, Yoji; Matsumoto, Yukihiro; Ibrahim, Osama M.A.; Okada, Naoko; Satake, Yoshiyuki; Fukagawa, Kazumi; Shimazaki, Jun; Tsubota, Kazuo; Fujishima, Hiroshi

    2010-01-01

    Background Although the oxidative stress status in atopic skin disease has been reported to be elevated, there are still no studies related to the status of oxidative stress in atopic ocular surface disease. The purpose of this study was to evaluate the ocular surface lipid oxidative stress status and inflammation in atopic keratoconjunctivitis (AKC) patients and normal subjects. Methods Twenty eight eyes of 14 patients (9 males, 5 females) with AKC and 18 eyes of 9 age and sex matched (4 males and 5 females) normal healthy controls were examined in this prospective study. The severity of atopic dermatitis (AD) was scored by the SCORing Atopic Dermatitis (SCORAD) index. All subjects underwent Schirmer test, tear film break up time (BUT), fluorescein/Rose Bengal stainings, tear collection, and brush cytology from the upper palpebral conjunctiva. The brush cytology samples were stained with Diff-Quik for differentiation of inflammatory cells and immunohistochemistry (IHC) staining with HEL (hexanoyl-lysine) and 4-HNE (4-hydroxy-2-nonenal) to study lipid oxidation. HEL and cytokine (interleukin-4 (IL-4), interleukin-5 (IL-5), interleukin-10 (IL-10), tumor necrosis factor-alpha (TNF-α), interferon-gamma (IFN-γ)) levels were measured by enzyme-linked immunosorbent assay (ELISA) from tear samples of AKC patients and control subjects. Toluidine Blue and IHC staining with HEL, 4-HNE and cluster of differentiation 45 (CD45) were performed on papillary samples of AKC patients. This study was conducted in compliance with the “Declaration of Helsinki.” Results The tear stability and vital staining scores were significantly worse in eyes of AKC patients (p<0.05) compared to the controls. Inflammatory cells and positively stained conjunctival epithelial cells for HEL and 4-HNE showed a significant elevation in brush cytology samples of AKC patients. Significantly higher levels of HEL and cytokines were detected in tears of AKC patients compared to controls. Papillary specimens also revealed many CD45 inflammatory cells as well as many cells positively stained with HEL and 4-HNE in IHC. A strong significant linear positive correlation between conjunctival inflammation and epithelial lipid oxidative stress status was observed. Conjunctival lipid oxidative stress also correlated strongly with tear HEL levels and epithelial damage scores. Conclusions The ocular surface disease in AKC was characterized by marked tear instability, ocular surface epithelial damage, increase in inflammatory infiltrates and presence of increased lipid oxidation. PMID:21139696

  1. Optimised laser microdissection of the human ocular surface epithelial regions for microarray studies

    PubMed Central

    2013-01-01

    Background The most important challenge of performing insitu transcriptional profiling of the human ocular surface epithelial regions is obtaining samples in sufficient amounts, without contamination from adjacent tissue, as the region of interest is microscopic and closely apposed to other tissues regions. We have effectively collected ocular surface (OS) epithelial tissue samples from the Limbal Epithelial Crypt (LEC), limbus, cornea and conjunctiva of post-mortem cadaver eyes with laser microdissection (LMD) technique for gene expression studies with spotted oligonucleotide microarrays and Gene 1.0 ST arrays. Methods Human donor eyes (4 pairs for spotted oligonucleotide microarrays, 3 pairs for Gene 1.0 ST arrays) consented for research were included in this study with due ethical approval of the Nottingham Research Ethics Committee. Eye retrieval was performed within 36 hours of post-mortem period. The dissected corneoscleral buttons were immersed in OCT media and frozen in liquid nitrogen and stored at −80°C till further use. Microscopic tissue sections of interest were taken on PALM slides and stained with Toluidine Blue for laser microdissection with PALM microbeam systems. Optimisation of the laser microdissection technique was crucial for efficient and cost effective sample collection. Results The starting concentration of RNA as stipulated by the protocol of microarray platforms was taken as the cut-off concentration of RNA samples in our studies. The area of LMD tissue processed for spotted oligonucleotide microarray study ranged from 86,253 μm2 in LEC to 392,887 μm2 in LEC stroma. The RNA concentration of the LMD samples ranged from 22 to 92 pg/μl. The recommended starting concentration of the RNA samples used for Gene 1.0 ST arrays was 6 ng/5 μl. To achieve the desired RNA concentration the area of ocular surface epithelial tissue sample processed for the Gene 1.0 ST array experiments was approximately 100,0000 μm2 to 130,0000 μm2. RNA concentration of these samples ranged from 10.88 ng/12 μl to 25.8 ng/12 μl, with the RNA integrity numbers (RIN) for these samples from 3.3 to 7.9. RNA samples with RIN values below 2, that had failed to amplify satisfactorily were discarded. Conclusions The optimised protocol for sample collection and laser microdissection improved the RNA yield of the insitu ocular surface epithelial regions for effective microarray studies on spotted oligonucleotide and affymetrix platforms. PMID:24160452

  2. Vestibular evoked myogenic potentials (VEMPs) in central neurological disorders.

    PubMed

    Venhovens, J; Meulstee, J; Verhagen, W I M

    2016-01-01

    Several types of acoustic stimulation (i.e. tone bursts or clicks), bone-conducted vibration, forehead taps, and galvanic stimulation elicit myogenic potentials. These can be recorded in cervical and ocular muscles, the so called vestibular evoked myogenic potentials (VEMPs). The cervical VEMP (cVEMP) resembles the vestibulo-collic reflex and the responses can be recorded from the ipsilateral sternocleidomastoid muscle. The ocular VEMP resembles the vestibulo-ocular reflex and can be recorded from extra-ocular muscles by a surface electrode beneath the contralateral infraorbital margin. Initially, the literature concerning VEMPs was limited to peripheral vestibular disorders, however, the field of VEMP testing is rapidly expanding, with an increasing focus on central neurological disorders. The current literature concerning VEMP abnormalities in central neurological disorders is critically reviewed, especially regarding the methodological aspects in relation to quality as well as the clinical interpretation of the VEMP results. Suggestions for further research are proposed as well as some clinically useful indications. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. The improvement of dry eye after cataract surgery by intraoperative using ophthalmic viscosurgical devices on the surface of cornea

    PubMed Central

    He, Yuan; Li, Jia; Zhu, Jingfen; Jie, Ying; Wang, Ningli; Wang, Jun

    2017-01-01

    Abstract Backgroud: This study aimed to investigate the protective effect of intraoperative used hydroxypropyl methylcellulose (HPMC 2%) on the ocular surface after cataract surgery. Methods: A total of 149 eyes (149 patients) diagnosed with age-related cataract, age 69.19 ± 9.74 years, were enrolled in this prospective, parallel-design, continuous, randomised controlled study. Patients were randomly assigned to receive HPMC 2% (study group) or balanced salt solution (control group) during the surgery to moisturize the cornea surface. The Ocular Surface Disease Index, Schirmer test without topical anesthetics, tear break-up time, and corneal fluorescein staining were assessed preoperatively, 1 day, 1 week, and 1 month after the surgery, respectively. Results: The Schirmer test value of male patients in the study group at 1 week postoperation was higher than that of male patients in the control group (P = .019). For patients diagnosed with dry eye before the surgery, Schirmer test value in the male patients in the study group at 1 month after surgery was higher than that in the male patients in the control group (P = .037). Furthermore, for the cluster of preoperative dry eye patients whose surgical time was longer than median, corneal fluorescein staining of the patients in the study group was superior to that of the patients in the control group (P = .032). Conclusion: Intraoperative use of HPMC 2% on the cornea surface could improve clinical outcomes of tear film and ocular surface health to some degree, especially in the patients diagnosed with dry eye before the surgery, male patients, and patients whose surgical time was relatively longer. PMID:29390284

  4. Correlation of corneal thickness, endothelial cell density and anterior chamber depth with ocular surface temperature in normal subjects.

    PubMed

    Pattmöller, Johanna; Wang, Jiong; Zemova, Elena; Seitz, Berthold; Eppig, Timo; Langenbucher, Achim; Szentmáry, Nóra

    2015-09-01

    To analyze corneal surface temperature profile in a young and healthy study population and to determine the impact of corneal thickness (CT), anterior chamber depth (ACD), and endothelial cell density (ECD) on surface temperature. In this prospective, single-center study 61 healthy right eyes of 61 subjects without tear film pathologies (mean age 24.9 ± 6.7 years) were recruited. Ocular surface temperature (OST) was measured with the Ocular Surface Thermographer TG-1000. From Pentacam HR CT and ACD, and from specular microscopy ECD and central corneal thickness (CCT) were acquired. From the raw measurement data (OST, CT and ACD) we extracted a) local OST the corneal center and 3mm away from the center at the 3, 6, and 9 o'clock positions, and b) Zernike parameters Z1, Z2 and Z3 to evaluate the general temperature profile within a 6mm circular area around the center. Overall, there was no correlation between OST and CT, ACD or ECD. Local OST did not correlate with CT at any measurement position. On average local OST was highest at measurement positions where CT was lowest, but without reaching statistical significance. Baseline OST was highest at thin corneal regions and temperature decay over time was smallest in those regions. Z1, Z2 and Z3 correlated well with CT. In healthy subjects corneal thickness, endothelial cell density and anterior chamber depth have no effect on corneal surface temperature. The general temperature profile seems to be influenced by the corneal thickness profile effecting a higher temperature and lower decay at thinner corneal regions. Copyright © 2014. Published by Elsevier GmbH.

  5. The relationship between demodex and ocular discomfort.

    PubMed

    Lee, Seok Hyun; Chun, Yeoun Sook; Kim, Jae Hoon; Kim, Eung Suk; Kim, Jae Chan

    2010-06-01

    To determine the correlative relationship between the prevalence of Demodex in eyelashes and the severity of ocular discomfort, by investigating the demographic epidemiology associated with Demodex. One hundred seventy patients underwent epilation of four eyelashes of each eye, and the number of Demodex was counted. The patients answered questionnaires about ocular surface discomfort and underwent ophthalmic examinations, including slit lamp, tear film breakup time (BUT), Schirmer test, and microbial culturing. The correlative relationship between the number of Demodex and these variable data was analyzed. Demodex was found in 120 (70%) of the 170 tested patients. Of 1360 eyelashes, 740 (54%) had Demodex. There was no significant difference in the prevalence of Demodex between males and females (P = 0.35). The number of Demodex showed significant positive correlations with increased age, ocular discomfort, and 1/BUT (P < 0.001), but not with the Schirmer scores. The number of Demodex was significantly higher in patients with conjunctival papillary hypertrophy than in those without (P = 0.003). The presence or distribution of bacteria on eyelashes was similar between eyelids with and without Demodex. However, methicillin-resistant Staphylococcus aureus (MRSA) was detected more often on eyelids with Demodex, but this difference was not statistically significant. There is a strong correlation between the number of Demodex and the severity of ocular discomfort, suggesting that Demodex plays a pathogenic role in the ocular discomfort linked with aging.

  6. Eye and orbit ultrasound

    MedlinePlus

    Echography - eye orbit; Ultrasound - eye orbit; Ocular ultrasonography; Orbital ultrasonography ... eye is numbed with medicine (anesthetic drops). The ultrasound wand (transducer) is placed against the front surface ...

  7. Fundoscopy Exam

    NASA Image and Video Library

    2015-08-05

    ISS044E033352 (08/05/2015) --- NASA astronaut Scott Kelly (left) assists Japan Aerospace Exploration Agency (JAXA) astronaut Kimiya Yui (right) with measurements for the ongoing Ocular Health study. Yui is seen operating a device called a Fundoscope which is used to take images of the retinal surface of an astronaut’s eye. Ocular Health is gathering data on crew visual health during and after long-duration space station missions to characterize how living in microgravity can affect the visual, vascular and central nervous systems.

  8. Model-based conifer crown surface reconstruction from multi-ocular high-resolution aerial imagery

    NASA Astrophysics Data System (ADS)

    Sheng, Yongwei

    2000-12-01

    Tree crown parameters such as width, height, shape and crown closure are desirable in forestry and ecological studies, but they are time-consuming and labor intensive to measure in the field. The stereoscopic capability of high-resolution aerial imagery provides a way to crown surface reconstruction. Existing photogrammetric algorithms designed to map terrain surfaces, however, cannot adequately extract crown surfaces, especially for steep conifer crowns. Considering crown surface reconstruction in a broader context of tree characterization from aerial images, we develop a rigorous perspective tree image formation model to bridge image-based tree extraction and crown surface reconstruction, and an integrated model-based approach to conifer crown surface reconstruction. Based on the fact that most conifer crowns are in a solid geometric form, conifer crowns are modeled as a generalized hemi-ellipsoid. Both the automatic and semi-automatic approaches are investigated to optimal tree model development from multi-ocular images. The semi-automatic 3D tree interpreter developed in this thesis is able to efficiently extract reliable tree parameters and tree models in complicated tree stands. This thesis starts with a sophisticated stereo matching algorithm, and incorporates tree models to guide stereo matching. The following critical problems are addressed in the model-based surface reconstruction process: (1) the problem of surface model composition from tree models, (2) the occlusion problem in disparity prediction from tree models, (3) the problem of integrating the predicted disparities into image matching, (4) the tree model edge effect reduction on the disparity map, (5) the occlusion problem in orthophoto production, and (6) the foreshortening problem in image matching, which is very serious for conifer crown surfaces. Solutions to the above problems are necessary for successful crown surface reconstruction. The model-based approach was applied to recover the canopy surface of a dense redwood stand using tri-ocular high-resolution images scanned from 1:2,400 aerial photographs. The results demonstrate the approach's ability to reconstruct complicated stands. The model-based approach proposed in this thesis is potentially applicable to other surfaces recovering problems with a priori knowledge about objects.

  9. The Eye Drop Preservative Benzalkonium Chloride Potently Induces Mitochondrial Dysfunction and Preferentially Affects LHON Mutant Cells.

    PubMed

    Datta, Sandipan; Baudouin, Christophe; Brignole-Baudouin, Francoise; Denoyer, Alexandre; Cortopassi, Gino A

    2017-04-01

    Benzalkonium chloride (BAK) is the most commonly used eye drop preservative. Benzalkonium chloride has been associated with toxic effects such as "dry eye" and trabecular meshwork degeneration, but the underlying biochemical mechanism of ocular toxicity by BAK is unclear. In this study, we propose a mechanistic basis for BAK's adverse effects. Mitochondrial O2 consumption rates of human corneal epithelial primary cells (HCEP), osteosarcoma cybrid cells carrying healthy (control) or Leber hereditary optic neuropathy (LHON) mutant mtDNA [11778(G>A)], were measured before and after acute treatment with BAK. Mitochondrial adenosine triphosphate (ATP) synthesis and cell viability were also measured in the BAK-treated control: LHON mutant and human-derived trabecular meshwork cells (HTM3). Benzalkonium chloride inhibited mitochondrial ATP (IC50, 5.3 μM) and O2 consumption (IC50, 10.9 μM) in a concentration-dependent manner, by directly targeting mitochondrial complex I. At its pharmaceutical concentrations (107-667 μM), BAK inhibited mitochondrial function >90%. In addition, BAK elicited concentration-dependent cytotoxicity to cybrid cells (IC50, 22.8 μM) and induced apoptosis in HTM3 cells at similar concentrations. Furthermore, we show that BAK directly inhibits mitochondrial O2 consumption in HCEP cells (IC50, 3.8 μM) at 50-fold lower concentrations than used in eye drops, and that cells bearing mitochondrial blindness (LHON) mutations are further sensitized to BAK's mitotoxic effect. Benzalkonium chloride inhibits mitochondria of human corneal epithelial cells and cells bearing LHON mutations at pharmacologically relevant concentrations, and we suggest this is the basis of BAK's ocular toxicity. Prescribing BAK-containing eye drops should be avoided in patients with mitochondrial deficiency, including LHON patients, LHON carriers, and possibly primary open-angle glaucoma patients.

  10. The Eye Drop Preservative Benzalkonium Chloride Potently Induces Mitochondrial Dysfunction and Preferentially Affects LHON Mutant Cells

    PubMed Central

    Datta, Sandipan; Baudouin, Christophe; Brignole-Baudouin, Francoise; Denoyer, Alexandre; Cortopassi, Gino A.

    2017-01-01

    Purpose Benzalkonium chloride (BAK) is the most commonly used eye drop preservative. Benzalkonium chloride has been associated with toxic effects such as “dry eye” and trabecular meshwork degeneration, but the underlying biochemical mechanism of ocular toxicity by BAK is unclear. In this study, we propose a mechanistic basis for BAK's adverse effects. Method Mitochondrial O2 consumption rates of human corneal epithelial primary cells (HCEP), osteosarcoma cybrid cells carrying healthy (control) or Leber hereditary optic neuropathy (LHON) mutant mtDNA [11778(G>A)], were measured before and after acute treatment with BAK. Mitochondrial adenosine triphosphate (ATP) synthesis and cell viability were also measured in the BAK-treated control: LHON mutant and human-derived trabecular meshwork cells (HTM3). Results Benzalkonium chloride inhibited mitochondrial ATP (IC50, 5.3 μM) and O2 consumption (IC50, 10.9 μM) in a concentration-dependent manner, by directly targeting mitochondrial complex I. At its pharmaceutical concentrations (107–667 μM), BAK inhibited mitochondrial function >90%. In addition, BAK elicited concentration-dependent cytotoxicity to cybrid cells (IC50, 22.8 μM) and induced apoptosis in HTM3 cells at similar concentrations. Furthermore, we show that BAK directly inhibits mitochondrial O2 consumption in HCEP cells (IC50, 3.8 μM) at 50-fold lower concentrations than used in eye drops, and that cells bearing mitochondrial blindness (LHON) mutations are further sensitized to BAK's mitotoxic effect. Conclusions Benzalkonium chloride inhibits mitochondria of human corneal epithelial cells and cells bearing LHON mutations at pharmacologically relevant concentrations, and we suggest this is the basis of BAK's ocular toxicity. Prescribing BAK-containing eye drops should be avoided in patients with mitochondrial deficiency, including LHON patients, LHON carriers, and possibly primary open-angle glaucoma patients. PMID:28444329

  11. CON4EI: CONsortium for in vitro Eye Irritation testing strategy - EpiOcular™ time-to-toxicity (EpiOcular ET-50) protocols for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Kandarova, Helena; Letasiova, Silvia; Adriaens, Els; Guest, Robert; Willoughby, Jamin A; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was to develop tiered testing strategies for eye irritation assessment for all drivers of classification. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different alternative methods. Here, the results obtained with reconstructed human cornea-like epithelium (RhCE) EpiOcular™ in the EpiOcular time-to-toxicity Tests (Neat and Dilution ET-50 protocols) are presented. The primary aim of this study was to evaluate whether test methods can discriminate chemicals not requiring classification for serious eye damage/eye irritancy (No Category) from chemicals requiring classification and labelling for Category 1 and Category 2. In addition, the predictive capacity in terms of in vivo drivers of classification was investigated. The chemicals were tested in two independent runs by MatTek In Vitro Life Science Laboratories. Results of this study demonstrate very high specificity of both test protocols. With the existing prediction models described in the SOPs, the specificity of the Neat and Dilution method was 87% and 100%, respectively. The Dilution method was able to correctly predicting 66% of GHS Cat 2 chemicals, however, prediction of GHS Cat 1 chemicals was only 47%-55% using the current protocols. In order to achieve optimal prediction for all three classes, a testing strategy was developed which combines the most predictive time-points of both protocols and for tests liquids and solids separately. Using this new testing strategy, the sensitivity for predicting GHS Cat 1 and GHS Cat 2 chemicals was 73% and 64%, respectively and the very high specificity of 97% was maintained. None of the Cat 1 chemicals was underpredicted as GHS No Category. Further combination of the EpiOcular time-to-toxicity protocols with other validated in vitro systems evaluated in this project, should enable significant reduction and even possible replacement of the animal tests for the final assessment of the irritation potential in all of the GHS classes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Coupling Osmolarity Dynamics within Human Tear Film on an Eye-Shaped Domain

    NASA Astrophysics Data System (ADS)

    Li, Longfei; Braun, R. J.; Driscoll, T. A.; Henshaw, W. D.; Banks, J. W.; King-Smith, P. E.

    2013-11-01

    The concentration of ions in the tear film (osmolarity) is a key variable in understanding dry eye symptoms and disease. We derived a mathematical model that couples osmolarity (treated as a single solute) and fluid dynamics within the tear film on a 2D eye-shaped domain. The model concerns the physical effects of evaporation, surface tension, viscosity, ocular surface wettability, osmolarity, osmosis and tear fluid supply and drainage. We solved the governing system of coupled nonlinear PDEs using the Overture computational framework developed at LLNL, together with a new hybrid time stepping scheme (using variable step BDF and RKC) that was added to the framework. Results of our numerical simulations show good agreement with existing 1D models (for both tear film and osmolarity dynamics) and provide new insight about the osmolarity distribution over the ocular surface during the interblink.

  13. Ocular toxicity and functional vision recovery in a patient treated with hydroxychloroquine.

    PubMed

    Rodríguez-Hurtado, Francisco Jorge; Sáez-Moreno, José Antonio; Rodríguez-Ferrer, José Manuel

    2015-01-01

    We report the case of a 64-year-old woman with rheumatoid arthritis and Sjögren's syndrome, treated during 48 months with hydroxychloroquine that was removed after an ophthalmological evaluation showed bilateral vision loss associated with paracentral scotoma in the visual field, fundoscopic macular pigmentary changes, and severely impaired central multifocal electrorretinogram (mfERG). Twelve months after treatment withdrawal, visual acuity and central mfERG had surprisingly improved. This is an unusual case of functional recovery after treatment withdrawal. We consider that central mfERG is a more sensitive test than pattern electrorretinogram in the detection of retinal toxicity and functional vision recovery after hydroxychloroquine treatment cessation. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  14. Safety Assessment of Alkyl PEG Sulfosuccinates as Used in Cosmetics.

    PubMed

    Johnson, Wilbur; Heldreth, Bart; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2015-09-01

    The Cosmetic Ingredient Review (CIR) Expert Panel (Panel) reviewed the safety of alkyl polyethylene glycol (PEG) sulfosuccinates, which function in cosmetics mostly as surfactants/cleansing agents. Although these ingredients may cause ocular and skin irritation, dermal penetration is unlikely because of the substantial polarity and molecular size of these ingredients. The Panel considered the negative oral carcinogenicity and reproductive and developmental toxicity data on chemically related laureths (PEG lauryl ethers) and negative repeated dose toxicity and skin sensitization data on disodium laureth sulfosuccinate supported the safety of these alkyl PEG sulfosuccinates in cosmetic products, but. The CIR Expert Panel concluded that the alkyl PEG sulfosuccinates are safe in the present practices of use and concentration when formulated to be nonirritating. © The Author(s) 2015.

  15. Intracellular trafficking of hyaluronic acid-chitosan oligomer-based nanoparticles in cultured human ocular surface cells.

    PubMed

    Contreras-Ruiz, Laura; de la Fuente, María; Párraga, Jenny E; López-García, Antonio; Fernández, Itziar; Seijo, Begoña; Sánchez, Alejandro; Calonge, Margarita; Diebold, Yolanda

    2011-01-27

    Nanoparticles are a promising alternative for ocular drug delivery, and our group has proposed that they are especially suited for ocular mucosal disorders. The goal of the present study was to determine which internalization pathway is used by cornea-derived and conjunctiva-derived cell lines to take up hyaluronic acid (HA)-chitosan oligomer (CSO)-based nanoparticles (HA-CSO NPs). We also determined if plasmids loaded onto the NPs reached the cell nucleus. HA-CSO NPs were made of fluoresceinamine labeled HA and CSO by ionotropic gelation and were conjugated with a model plasmid DNA for secreted alkaline phosphatase. Human epithelial cell lines derived from the conjunctiva and the cornea were exposed to HA-CSO NPs for 1 h and the uptake was investigated in living cells by fluorescence microscopy. The influence of temperature and metabolic inhibition, the effect of blocking hyaluronan receptors, and the inhibition of main endocytic pathways were studied by fluorometry. Additionally, the metabolic pathways implicated in the degradation of HA-CSO NPs were evaluated by lysosome identification. There was intracellular localization of plasmid-loaded HACSO NPs in both corneal and conjunctival cells. The intracellular presence of NPs diminished with time. HA-CSO NP uptake was significantly reduced by inhibition of active transport at 4 °C and by sodium azide. Uptake was also inhibited by blocking hyaluronan receptors with anti-CD44 Hermes-1 antibody, by excess HA, and by filipin, an inhibitor of caveolin-dependent endocytosis. HA-CSO NPs had no effect on cell viability. The transfection efficiency of the model plasmid was significantly higher in NP treated cells than in controls. HA-CSO NPs were internalized by two different ocular surface cell lines by an active transport mechanism. The uptake was mediated by hyaluronan receptors through a caveolin-dependent endocytic pathway, yielding remarkable transfection efficiency. Most of HA-CSO NPs were metabolized within 48 h. This uptake did not compromise cell viability. These findings further support the potential use of HA-CSO NPs to deliver genetic material to the ocular surface.

  16. Anterior segment and external ocular disorders associated with HIV infections in the era of HAART in Chiang Mai University Hospital, a prospective descriptive cross sectional study.

    PubMed

    Singalavanija, Tassapol; Ausayakhun, Somsanguan; Tangmonkongvoragul, Chulaluck

    2018-01-01

    Human immunodeficiency virus (HIV) causes impairment to the human immune system which leads to immunocompromised conditions, including ocular complications. Several important HIV-associated disorders may involve the anterior segment, ocular surface, and adnexae organ such as dry eye, blepharitis which reduce quality of life of patients. In present, potent antiretroviral therapies HAART (highly active antiretroviral therapy) has improved the length and quality of life which may lead to an increased prevalence of anterior segment ocular disorders. Hence, this study has been undertaken to identify the prevalence and associated factors of anterior segment and external ocular disorder in HIV infected patients in the era of HAART. A prospective descriptive cross sectional study was carried out in HIV positive patients conducted at the Department of Ophthalmology, Chiang Mai University Hospital, from February 2014 to October 2015. Detail history and ocular examination was carried out to examine for anterior segment and external ocular disorders. A total number of 363 patients were included for this prospective cross-sectional study. From the total of 363 patients, 123 patients had an anterior segment and external ocular disorder which account as the prevalence of 33.9%. The most common anterior segment manifestations was dry eye seen in 36 patients (9.9%), followed by posterior blepharitis (Meibomian gland dysfunction) seen in 23 patients (6.3%) and anterior blepharitis seen in 12 patients (3.3%). Other ocular complications included microvasculopathy, immune recovery uveitis, conjunctivitis, papilloma, anterior uveitis, corneal ulcer, nevus, trichiasis, molluscum contangiosum, Kaposi sarcoma, interstitial keratitis, conjunctival lymphangiectasia, dacryocystitis, vernal keratoconjunctivitis and eyelid penicilosis. In this study, the prevalance of anterior segment disorders was higher than in the preHAART era. Dry eye, blepharitis and uveitis were the top three most common anterior segment disorders in the HAART era. The statistical analysis showed no association between age, sex, CD4 count, duration of infection or receiving HAART and anterior segment disorders. Anterior segment abnormalities reduce the quality of life of patients, so ophthalmologists have to be aware and complete ocular examination should be performed in all HIV infected patients.

  17. Anterior segment and external ocular disorders associated with HIV infections in the era of HAART in Chiang Mai University Hospital, a prospective descriptive cross sectional study

    PubMed Central

    Ausayakhun, Somsanguan

    2018-01-01

    Human immunodeficiency virus (HIV) causes impairment to the human immune system which leads to immunocompromised conditions, including ocular complications. Several important HIV-associated disorders may involve the anterior segment, ocular surface, and adnexae organ such as dry eye, blepharitis which reduce quality of life of patients. In present, potent antiretroviral therapies HAART (highly active antiretroviral therapy) has improved the length and quality of life which may lead to an increased prevalence of anterior segment ocular disorders. Hence, this study has been undertaken to identify the prevalence and associated factors of anterior segment and external ocular disorder in HIV infected patients in the era of HAART. A prospective descriptive cross sectional study was carried out in HIV positive patients conducted at the Department of Ophthalmology, Chiang Mai University Hospital, from February 2014 to October 2015. Detail history and ocular examination was carried out to examine for anterior segment and external ocular disorders. A total number of 363 patients were included for this prospective cross-sectional study. From the total of 363 patients, 123 patients had an anterior segment and external ocular disorder which account as the prevalence of 33.9%. The most common anterior segment manifestations was dry eye seen in 36 patients (9.9%), followed by posterior blepharitis (Meibomian gland dysfunction) seen in 23 patients (6.3%) and anterior blepharitis seen in 12 patients (3.3%). Other ocular complications included microvasculopathy, immune recovery uveitis, conjunctivitis, papilloma, anterior uveitis, corneal ulcer, nevus, trichiasis, molluscum contangiosum, Kaposi sarcoma, interstitial keratitis, conjunctival lymphangiectasia, dacryocystitis, vernal keratoconjunctivitis and eyelid penicilosis. In this study, the prevalance of anterior segment disorders was higher than in the preHAART era. Dry eye, blepharitis and uveitis were the top three most common anterior segment disorders in the HAART era. The statistical analysis showed no association between age, sex, CD4 count, duration of infection or receiving HAART and anterior segment disorders. Anterior segment abnormalities reduce the quality of life of patients, so ophthalmologists have to be aware and complete ocular examination should be performed in all HIV infected patients. PMID:29466424

  18. Electrically atomised formulations of timolol maleate for direct and on-demand ocular lens coatings.

    PubMed

    Mehta, Prina; Al-Kinani, Ali A; Haj-Ahmad, Rita; Arshad, Muhammad Sohail; Chang, Ming-Wei; Alany, Raid G; Ahmad, Zeeshan

    2017-10-01

    Advances in nanotechnology have enabled solutions for challenging drug delivery targets. While the eye presents numerous emerging opportunities for delivery, analysis and sensing; issues persist for conventional applications. This includes liquid phase formulation localisation on the ocular surface once administered as formulated eye-drops; with the vast majority of dosage (>90%) escaping from the administered site due to tear production and various drainage mechanisms. The work presented here demonstrates a single needle electrohydrodynamic (EHD) engineering process to nano-coat (as an on demand and controllable fiber depositing method) the surface of multiple contact lenses rendering formulations to be stationary on the lens and at the bio-interface. The coating process was operational based on ejected droplet charge and glaucoma drug timolol maleate (TM) was used to demonstrate surface coating optimisation, bio-surface permeation properties (flux, using a bovine model) and various kinetic models thereafter. Polymers PVP, PNIPAM and PVP:PNIPAM (50:50%w/w) were used to encapsulate the active. Nano-fibrous and particulate samples were characterised using SEM, FTIR, DSC and TGA to confirm structural and thermal stability of surface coated formulations. More than 52% of nano-structured coatings (for all formulations) were <200nm in diameter. In vitro studies show coatings to exhibit biphasic release profiles; an initial burst release followed by sustained release; with TM-loaded PNIPAM coating releasing most drug after 24h (89.8%). Kinetic modelling (Higuchi, Korsmeyer-Peppas) was indicative of quasi-Fickian diffusion whilst biological evaluation demonstrates adequate ocular tolerability. Results from permeation studies indicate coated lenses are ideal to reduce dosing regimen, which in turn will reduce systemic drug absorption. Florescent microscopy demonstrated probe and probe embedded coating behaviour from lens surface in vitro. The multiple lens surface coating method demonstrates sustained drug release yielding promising results; suggesting both novel device and method to enhance drug activity at the eyes surface which will reduce formulation drainage. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  19. Immunohistochemical localization of calcium-binding proteins in the brainstem vestibular nuclei of the jaundiced Gunn rat.

    PubMed

    Shaia, Wayne T; Shapiro, Steven M; Heller, Andrew J; Galiani, David L; Sismanis, Aristides; Spencer, Robert F

    2002-11-01

    Vestibular gaze and postural abnormalities are major sequelae of neonatal hyperbilirubinemia. The sites and cellular effects of bilirubin toxicity in the brainstem vestibular pathway are not easily detected. Since altered intracellular calcium homeostasis may play a role in neuronal cell death, we hypothesized that altered expression of calcium-binding proteins may occur in brainstem vestibular nuclei of the classic animal model of bilirubin neurotoxicity. The expression of the calcium-binding proteins calbindin-D28k and parvalbumin in the brainstem vestibular pathways and cerebellum of homozygous recessive jaundiced (jj) Gunn rats was examined by light microscopy and immunohistochemistry at 18 days postnatally and compared to the findings obtained from age-matched non-jaundiced heterozygous (Nj) littermate controls. Jaundiced animals exhibited decreased parvalbumin immunoreactivity specifically in synaptic inputs to superior, medial, and inferior vestibular nuclei, and to oculomotor and trochlear nuclei, whereas the neurons retained their normal immunoreactivity. Jaundiced animals also demonstrated a decrease in calbindin expression in the lateral vestibular nuclei and a paucity of calbindin-immunoreactive synaptic endings on the somata of Deiters' neurons. The involved regions are related to the control of the vestibulo-ocular and vestibulospinal reflexes. Decreased expression of calcium-binding proteins in brainstem vestibular neurons may relate to the vestibulo-ocular and vestibulospinal dysfunction seen with clinical kernicterus, and may provide a sensitive new way to assess bilirubin toxicity in the vestibular system.

  20. Pharmacokinetic Studies of Sustained-Release Depot of Dexamethasone in Beagle Dogs.

    PubMed

    Blizzard, Charles; Desai, Ankita; Driscoll, Arthur

    2016-11-01

    To examine the pharmacokinetic characteristics of sustained-release dexamethasone depots in two separate canine studies. Dexamethasone depots loaded with a clinically representative (0.4 mg) dose (DEXTENZA™; Ocular Therapeutix) or an elevated (0.7 mg) dose were inserted into the canaliculi of beagle eyes (n = 37 and n = 34, respectively). Tear fluid was collected for pharmacokinetic analysis of dexamethasone in both studies at predetermined time points. Explanted 0.4 mg depots were collected weekly to measure remaining drug level. Clinical observations and ophthalmic examinations were performed in both studies at each visit. The 0.4 mg depots released a median 308 μg by day 15 and tapered to complete drug release by day 28. Median dexamethasone tear fluid concentrations in the 0.4 mg study group decreased from 2,805 ng/mL at day 7 to 0 ng/mL on day 28. Median dexamethasone tear fluid concentrations in the 0.7 mg study group decreased from 4,370 ng/mL at 6 h post insertion to 830 ng/mL on day 35. Mean ± standard deviation intraocular pressures in the 0.4 and 0.7 mg study groups were 20.7 ± 2.8 and 19.0 ± 4.1 mmHg at baseline, respectively, and demonstrated no meaningful change (20.5 ± 3.0 and 20.6 ± 2.9 mmHg, respectively) over the studies' durations. No ocular toxicities were attributed to the dexamethasone depot. Sustained-release dexamethasone produced no identifiable ocular toxicity in this animal model, and pharmacokinetics demonstrated a sustained and tapered drug release over 28 days at a 0.4 mg dose and exceeded 35 days at a 0.7 mg dose.

Top