Izewska, Joanna; Georg, Dietmar; Bera, Pranabes; Thwaites, David; Arib, Mehenna; Saravi, Margarita; Sergieva, Katia; Li, Kaibao; Yip, Fernando Garcia; Mahant, Ashok Kumar; Bulski, Wojciech
2007-07-01
A strategy for national TLD audit programmes has been developed by the International Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for high-energy photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon and electron beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and asymmetric fields for photon beams. Through a co-ordinated research project the IAEA developed the methodology to extend the scope of national TLD auditing activities to more complex audit measurements for regular fields. Based on the IAEA standard TLD holder for high-energy photon beams, a TLD holder was developed with horizontal arm to enable measurements 5cm off the central axis. Basic correction factors were determined for the holder in the energy range between Co-60 and 25MV photon beams. New procedures were developed for the TLD irradiation in hospitals. The off-axis measurement methodology for photon beams was tested in a multi-national pilot study. The statistical distribution of dosimetric parameters (off-axis ratios for open and wedge beam profiles, output factors, wedge transmission factors) checked in 146 measurements was 0.999+/-0.012. The methodology of TLD audits in non-reference conditions with a modified IAEA TLD holder has been shown to be feasible.
Ophus, Colin; Rasool, Haider I.; Linck, Martin; ...
2016-11-30
We develop an automatic and objective method to measure and correct residual aberrations in atomic-resolution HRTEM complex exit waves for crystalline samples aligned along a low-index zone axis. Our method uses the approximate rotational point symmetry of a column of atoms or single atom to iteratively calculate a best-fit numerical phase plate for this symmetry condition, and does not require information about the sample thickness or precise structure. We apply our method to two experimental focal series reconstructions, imaging a β-Si 3N 4 wedge with O and N doping, and a single-layer graphene grain boundary. We use peak and latticemore » fitting to evaluate the precision of the corrected exit waves. We also apply our method to the exit wave of a Si wedge retrieved by off-axis electron holography. In all cases, the software correction of the residual aberration function improves the accuracy of the measured exit waves.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ophus, Colin; Rasool, Haider I.; Linck, Martin
We develop an automatic and objective method to measure and correct residual aberrations in atomic-resolution HRTEM complex exit waves for crystalline samples aligned along a low-index zone axis. Our method uses the approximate rotational point symmetry of a column of atoms or single atom to iteratively calculate a best-fit numerical phase plate for this symmetry condition, and does not require information about the sample thickness or precise structure. We apply our method to two experimental focal series reconstructions, imaging a β-Si 3N 4 wedge with O and N doping, and a single-layer graphene grain boundary. We use peak and latticemore » fitting to evaluate the precision of the corrected exit waves. We also apply our method to the exit wave of a Si wedge retrieved by off-axis electron holography. In all cases, the software correction of the residual aberration function improves the accuracy of the measured exit waves.« less
Krause, Matthias; Drenck, Tobias Claus; Korthaus, Alexander; Preiss, Achim; Frosch, Karl-Heinz; Akoto, Ralph
2018-06-01
The primary purpose of the study was to gain insight into geometric changes of the patellar height (PH) and posterior tibial slope (PTS) after a biplanar ascending medial open-wedge high tibial osteotomy (HTO) compared to biplanar descending medial open-wedge HTO in patients with genu varum. Sixty-four patients (mean age 45.2 ± 8.7 years, females n = 24, males n = 40) with varus malalignment and medial gonarthrosis were retrospectively studied. Patients received either a biplanar ascending or descending medial open-wedge HTO. Radiographic analysis included the assessment of standing total leg axis, PH, and PTS prior to and after surgery. In the ascending HTO group, PH decreased significantly by 4.0% (p = 0.037, Caton-Deschamps index) after an average leg axis valgus-producing correction of 7.1° ± 2.8°. In the descending HTO group, with an average leg axis correction of 7.0° ± 3.7°, there were no significant PH changes. There were no significant differences between the ascending and descending HTO groups regarding PTS or leg axis. The mean post-operative leg axis between ascending (1.6° ± 1.9°) and descending HTO (1.9° ± 2.4°) was not significantly different. Compared to the biplanar ascending medial open-wedge HTO, the descending HTO did not influence patella height or increase the posterior tibial slope. In order to respect patellofemoral and slope-related knee kinematics, a biplanar descending medial open-wedge HTO has proven useful to control patella height and posterior tibial slope. These findings underscore the importance of the preoperative patella height assessment in the osteotomy planning and subsequent choice of the biplanar osteotomy direction. IV.
Lee, Dae-Hee; Park, Sung-Chul; Park, Hyung-Joon; Han, Seung-Beom
2016-12-01
Open-wedge high tibial osteotomy (HTO) cannot always accurately correct limb alignment, resulting in under- or over-correction. This study assessed the relationship between soft tissue laxity of the knee joint and alignment correction in open-wedge HTO. This prospective study involved 85 patients (86 knees) undergoing open-wedge HTO for primary medial osteoarthritis. The mechanical axis (MA), weight-bearing line (WBL) ratio, and joint line convergence angle (JLCA) were measured on radiographs preoperatively and after 6 months, and the differences between the pre- and post-surgery values were calculated. Post-operative WBL ratios of 57-67 % were classified as acceptable correction. WBL ratios <57 and >67 % were classified as under- and over-corrections, respectively. Preoperative JLCA correlated positively with differences in MA (r = 0.358, P = 0.001) and WBL ratio (P = 0.003). Difference in JLCA showed a stronger correlation than preoperative JLCA with differences in MA (P < 0.001) and WBL ratio (P < 0.001). Difference in JLCA was the only predictor of both difference in MA (P < 0.001) and difference in WBL ratio (P < 0.001). The difference between pre- and post-operative JLCA differed significantly between the under-correction, acceptable-correction, and over-correction groups (P = 0.033). Preoperative JLCA, however, did not differ significantly between the three groups. Neither preoperative JLCA nor difference in JLCA correlated with change in posterior slope. Preoperative degree of soft tissue laxity in the knee joint was related to the degree of alignment correction, but not to alignment correction error, in open-wedge HTO. Change in soft tissue laxity around the knee from before to after open-wedge HTO correlated with both correction amount and correction error. Therefore, a too large change in JLCA from before to after open-wedge osteotomy may be due to an overly large reduction in JLCA following osteotomy, suggesting alignment over-correction during surgery. II.
Sediment Pathways Across Trench Slopes: Results From Numerical Modeling
NASA Astrophysics Data System (ADS)
Cormier, M. H.; Seeber, L.; McHugh, C. M.; Fujiwara, T.; Kanamatsu, T.; King, J. W.
2015-12-01
Until the 2011 Mw9.0 Tohoku earthquake, the role of earthquakes as agents of sediment dispersal and deposition at erosional trenches was largely under-appreciated. A series of cruises carried out after the 2011 event has revealed a variety of unsuspected sediment transport mechanisms, such as tsunami-triggered sheet turbidites, suggesting that great earthquakes may in fact be important agents for dispersing sediments across trench slopes. To complement these observational data, we have modeled the pathways of sediments across the trench slope based on bathymetric grids. Our approach assumes that transport direction is controlled by slope azimuth only, and ignores obstacles smaller than 0.6-1 km; these constraints are meant to approximate the behavior of turbidites. Results indicate that (1) most pathways issued from the upper slope terminate near the top of the small frontal wedge, and thus do not reach the trench axis; (2) in turn, sediments transported to the trench axis are likely derived from the small frontal wedge or from the subducting Pacific plate. These results are consistent with the stratigraphy imaged in seismic profiles, which reveals that the slope apron does not extend as far as the frontal wedge, and that the thickness of sediments at the trench axis is similar to that of the incoming Pacific plate. We further applied this modeling technique to the Cascadia, Nankai, Middle-America, and Sumatra trenches. Where well-defined canyons carve the trench slopes, sediments from the upper slope may routinely reach the trench axis (e.g., off Costa Rica and Cascadia). In turn, slope basins that are isolated from the canyons drainage systems must mainly accumulate locally-derived sediments. Therefore, their turbiditic infill may be diagnostic of seismic activity only - and not from storm or flood activity. If correct, this would make isolated slope basins ideal targets for paleoseismological investigation.
NASA Astrophysics Data System (ADS)
Clark, J. D.; Stockli, D. F.; McKay, M. P.; Thomson, K.; Puigdefabregas, C.; Castelltort, S.; Dykstra, M.; Fildani, A.
2014-12-01
Until the 2011 Mw9.0 Tohoku earthquake, the role of earthquakes as agents of sediment dispersal and deposition at erosional trenches was largely under-appreciated. A series of cruises carried out after the 2011 event has revealed a variety of unsuspected sediment transport mechanisms, such as tsunami-triggered sheet turbidites, suggesting that great earthquakes may in fact be important agents for dispersing sediments across trench slopes. To complement these observational data, we have modeled the pathways of sediments across the trench slope based on bathymetric grids. Our approach assumes that transport direction is controlled by slope azimuth only, and ignores obstacles smaller than 0.6-1 km; these constraints are meant to approximate the behavior of turbidites. Results indicate that (1) most pathways issued from the upper slope terminate near the top of the small frontal wedge, and thus do not reach the trench axis; (2) in turn, sediments transported to the trench axis are likely derived from the small frontal wedge or from the subducting Pacific plate. These results are consistent with the stratigraphy imaged in seismic profiles, which reveals that the slope apron does not extend as far as the frontal wedge, and that the thickness of sediments at the trench axis is similar to that of the incoming Pacific plate. We further applied this modeling technique to the Cascadia, Nankai, Middle-America, and Sumatra trenches. Where well-defined canyons carve the trench slopes, sediments from the upper slope may routinely reach the trench axis (e.g., off Costa Rica and Cascadia). In turn, slope basins that are isolated from the canyons drainage systems must mainly accumulate locally-derived sediments. Therefore, their turbiditic infill may be diagnostic of seismic activity only - and not from storm or flood activity. If correct, this would make isolated slope basins ideal targets for paleoseismological investigation.
A two-dimensional matrix correction for off-axis portal dose prediction errors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bailey, Daniel W.; Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263; Kumaraswamy, Lalith
2013-05-15
Purpose: This study presents a follow-up to a modified calibration procedure for portal dosimetry published by Bailey et al. ['An effective correction algorithm for off-axis portal dosimetry errors,' Med. Phys. 36, 4089-4094 (2009)]. A commercial portal dose prediction system exhibits disagreement of up to 15% (calibrated units) between measured and predicted images as off-axis distance increases. The previous modified calibration procedure accounts for these off-axis effects in most regions of the detecting surface, but is limited by the simplistic assumption of radial symmetry. Methods: We find that a two-dimensional (2D) matrix correction, applied to each calibrated image, accounts for off-axismore » prediction errors in all regions of the detecting surface, including those still problematic after the radial correction is performed. The correction matrix is calculated by quantitative comparison of predicted and measured images that span the entire detecting surface. The correction matrix was verified for dose-linearity, and its effectiveness was verified on a number of test fields. The 2D correction was employed to retrospectively examine 22 off-axis, asymmetric electronic-compensation breast fields, five intensity-modulated brain fields (moderate-high modulation) manipulated for far off-axis delivery, and 29 intensity-modulated clinical fields of varying complexity in the central portion of the detecting surface. Results: Employing the matrix correction to the off-axis test fields and clinical fields, predicted vs measured portal dose agreement improves by up to 15%, producing up to 10% better agreement than the radial correction in some areas of the detecting surface. Gamma evaluation analyses (3 mm, 3% global, 10% dose threshold) of predicted vs measured portal dose images demonstrate pass rate improvement of up to 75% with the matrix correction, producing pass rates that are up to 30% higher than those resulting from the radial correction technique alone. As in the 1D correction case, the 2D algorithm leaves the portal dosimetry process virtually unchanged in the central portion of the detector, and thus these correction algorithms are not needed for centrally located fields of moderate size (at least, in the case of 6 MV beam energy).Conclusion: The 2D correction improves the portal dosimetry results for those fields for which the 1D correction proves insufficient, especially in the inplane, off-axis regions of the detector. This 2D correction neglects the relatively smaller discrepancies that may be caused by backscatter from nonuniform machine components downstream from the detecting layer.« less
Lavallé, F; Pascal-Mousselard, H; Rouvillain, J L; Ribeyre, D; Delattre, O; Catonné, Y
2004-10-01
The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy. Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined. Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively. Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.
NASA Technical Reports Server (NTRS)
Bizon, P. T.; Dreshfield, R. L.; Calfo, F. D.
1979-01-01
The effect of off-axis directionally solidified (DS) grain growth on thermal fatigue life of Mar-M 247 alloy was evaluated. Uncoated conventionally cast as well as DS wedge bars were cycled in a burner rig between 1070 C and room temperature. The longitudinal axis and leading edge of the specimen coincided. As the angle between the specimen longitudinal axis and growth axis increased, the thermal fatigue life decreased for both the uncoated and aluminide-coated bars. Life increases of about 50 cycles for the DS conditions were attributed to coating. The decrease in thermal fatigue life with increasing angle is primarily attributed to the increase in modulus of elasticity with increasing angle and not to the intersection of DS grain boundaries with the specimen leading edge. The thermal fatigue cracks were observed to be transgranular in the DS material. Limited tensile and stress-rupture properties of conventionally cast and off-axis DS Mar-M 247 alloy are also presented.
Analysis of nodal aberration properties in off-axis freeform system design.
Shi, Haodong; Jiang, Huilin; Zhang, Xin; Wang, Chao; Liu, Tao
2016-08-20
Freeform surfaces have the advantage of balancing off-axis aberration. In this paper, based on the framework of nodal aberration theory (NAT) applied to the coaxial system, the third-order astigmatism and coma wave aberration expressions of an off-axis system with Zernike polynomial surfaces are derived. The relationship between the off-axis and surface shape acting on the nodal distributions is revealed. The nodal aberration properties of the off-axis freeform system are analyzed and validated by using full-field displays (FFDs). It has been demonstrated that adding Zernike terms, up to nine, to the off-axis system modifies the nodal locations, but the field dependence of the third-order aberration does not change. On this basis, an off-axis two-mirror freeform system with 500 mm effective focal length (EFL) and 300 mm entrance pupil diameter (EPD) working in long-wave infrared is designed. The field constant aberrations induced by surface tilting are corrected by selecting specific Zernike terms. The design results show that the nodes of third-order astigmatism and coma move back into the field of view (FOV). The modulation transfer function (MTF) curves are above 0.4 at 20 line pairs per millimeter (lp/mm) which meets the infrared reconnaissance requirement. This work provides essential insight and guidance for aberration correction in off-axis freeform system design.
Türkmen, İsmail; Esenkaya, İrfan; Ünay, Koray; Türkmensoy, Fatih; Özkut, Afşar Timuçin
2014-01-01
Objectives: The purpose of this study is to evaluate the early results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for varus gonarthrosis and compare the results with the literatüre. Methods: The results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for 23 knees of 22 patients with medial gonarthrosis were evaluated clinically and radiologically. Results: Twenty of the patients were female and two were male. Mean age of the patients was 56.24; mean boy mass index was 31.95 and preoperative HSS (Hospital for Special Surgery) score was 68.7. Mean tibiofemoral axis was 186.39° and mean Insall-Salvatti index value was 1.04 preoperatively. Mean follow up period was 30.19 months. Mean HSS score was 86.48, femorotibial anatomic axis angle was 175° and Insall-Salvati index value 1.06 during the last follow-up. The improvement of the HSS score and the femorotibial anatomic axis angle was statistically significant. However, the change in Insall Salvati index values was statistically insignificant. Nonfatal pulmonary embolus in 1 patient, and deep vein thrombosis that occured one year after the procedure in 1 patient, rhabdomyolysis in 1 patient and loss of correction (relapse) in 1 patient were encountered as complications. Conclusion: Our results show that proximal tibia medial biplanar retrotubercle open wedge osteotomy improves the frontal and sagittal plane deformities without changing the patellar tendon length. Hence, possible patellofemoral problems are prevented and the clinical results are improved.
García-Garduño, Olivia A; Rodríguez-Ávila, Manuel A; Lárraga-Gutiérrez, José M
2018-01-01
Silicon-diode-based detectors are commonly used for the dosimetry of small radiotherapy beams due to their relatively small volumes and high sensitivity to ionizing radiation. Nevertheless, silicon-diode-based detectors tend to over-respond in small fields because of their high density relative to water. For that reason, detector-specific beam correction factors ([Formula: see text]) have been recommended not only to correct the total scatter factors but also to correct the tissue maximum and off-axis ratios. However, the application of [Formula: see text] to in-depth and off-axis locations has not been studied. The goal of this work is to address the impact of the correction factors on the calculated dose distribution in static non-conventional photon beams (specifically, in stereotactic radiosurgery with circular collimators). To achieve this goal, the total scatter factors, tissue maximum, and off-axis ratios were measured with a stereotactic field diode for 4.0-, 10.0-, and 20.0-mm circular collimators. The irradiation was performed with a Novalis® linear accelerator using a 6-MV photon beam. The detector-specific correction factors were calculated and applied to the experimental dosimetry data for in-depth and off-axis locations. The corrected and uncorrected dosimetry data were used to commission a treatment planning system for radiosurgery planning. Various plans were calculated with simulated lesions using the uncorrected and corrected dosimetry. The resulting dose calculations were compared using the gamma index test with several criteria. The results of this work presented important conclusions for the use of detector-specific beam correction factors ([Formula: see text] in a treatment planning system. The use of [Formula: see text] for total scatter factors has an important impact on monitor unit calculation. On the contrary, the use of [Formula: see text] for tissue-maximum and off-axis ratios has not an important impact on the dose distribution calculation by the treatment planning system. This conclusion is only valid for the combination of treatment planning system, detector, and correction factors used in this work; however, this technique can be applied to other treatment planning systems, detectors, and correction factors.
Inclined indentation of smooth wedge in rock mass
NASA Astrophysics Data System (ADS)
Chanyshev, AI; Podyminogin, GM; Lukyashko, OA
2018-03-01
The article focuses on the inclined rigid wedge indentation into a rigid-plastic half-plane of rocks with the Mohr–Coulomb-Mohr plasticity. The limiting loads on different sides of the wedge are determined versus the internal friction angle, cohesion and wedge angle. It is shown that when the force is applied along the symmetry axis of the wedge, the zone of plasticity is formed only on one wedge side. In order to form the plasticity zone on both sides of the wedge, it is necessary to apply the force asymmetrically relative to the wedge symmetry axis. An engineering solution for the asymmetrical case implementation is suggested.
NASA Technical Reports Server (NTRS)
Bowman, K.; Worden, H.; Beer, R.
1999-01-01
Spectra measured by off-axis detectors in a high-resolution Fourier transform spectrometer (FTS) are characterized by frequency scaling, asymmetry and broadening of their line shape, and self-apodization in the corresponding interferogram.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding
2012-08-15
Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receivingmore » a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.« less
Wylie, James D; Jones, Daniel L; Hartley, Melissa K; Kapron, Ashley L; Krych, Aaron J; Aoki, Stephen K; Maak, Travis G
2016-10-01
(1) To determine the radiographic correction/healing rate, patient-reported outcomes, reoperation rate, and complication rate after distal femoral osteotomy (DFO) for the valgus knee with lateral compartment pathology. (2) To summarize the reported results of medial closing wedge and lateral opening wedge DFO. We conducted a systematic review of PubMed, MEDLINE, and CINAHL to identify studies reporting outcomes of DFOs for the valgus knee. Keywords included "distal femoral osteotomy," "chondral," "cartilage," "valgus," "joint restoration," "joint preservation," "arthritis," and "gonarthrosis." Two authors first reviewed the articles; our study exclusion criteria were then applied, and the articles were included on the basis relevance defined by the aforementioned criteria. The Methodological Index for Nonrandomized Studies scale judged the quality of the literature. Sixteen studies were relevant to the research questions out of 191 studies identified by the original search. Sixteen studies were identified reporting on 372 osteotomies with mean follow-up of 45 to 180 months. All studies reported mean radiographic correction to a near neutral mechanical axis, with 3.2% nonunion and 3.8% delayed union rates. There was a 9% complication rate and a 34% reoperation rate, of which 15% were converted to arthroplasty. There were similar results reported for medial closing wedge and lateral opening wedge techniques, with a higher conversion to arthroplasty in the medial closing wedge that was confounded by longer mean follow-up in this group (mean follow-up 100 v 58 months). DFOs for the valgus knee with lateral compartment disease provide improvements in patient-reported knee health-related quality of life at midterm follow-up but have high rates of reoperation. No evidence exists proving better results of either the lateral opening wedge or medial closing wedge techniques. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Distortion definition and correction in off-axis systems
NASA Astrophysics Data System (ADS)
Da Deppo, Vania; Simioni, Emanuele; Naletto, Giampiero; Cremonese, Gabriele
2015-09-01
Off-axis optical configurations are becoming more and more used in a variety of applications, in particular they are the most preferred solution for cameras devoted to Solar System planets and small bodies (i.e. asteroids and comets) study. Off-axis designs, being devoid of central obstruction, are able to guarantee better PSF and MTF performance, and thus higher contrast imaging capabilities with respect to classical on-axis designs. In particular they are suitable for observing extended targets with intrinsic low contrast features, or scenes where a high dynamical signal range is present. Classical distortion theory is able to well describe the performance of the on-axis systems, but it has to be adapted for the off-axis case. A proper way to deal with off-axis distortion definition is thus needed together with dedicated techniques to accurately measure and hence remove the distortion effects present in the acquired images. In this paper, a review of the distortion definition for off-axis systems will be given. In particular the method adopted by the authors to deal with the distortion related issues (definition, measure, removal) in some off-axis instruments will be described in detail.
1997-11-01
Expanded subset of the illustration to clarify the locus of the off-axis end point of retinal stimulation for correct accommodation. 55 Figure...12c. Expanded illustration to clarify the locus of the off -axis end point of retinal stimulation for myopic accommodation. 55 Figure 12d...Expanded illustration to clarify the locus of the off -axis end point of retinal stimulation for hyperopic accommodation. 56 Figure 13. Simplified
Characterization of an in vivo diode dosimetry system for clinical use
Huang, Kai; Bice, William S.; Hidalgo‐Salvatierra, Oscar
2003-01-01
An in vivo dosimetry system that uses p‐type semiconductor diodes with buildup caps was characterized for clinical use on accelerators ranging in energy from 4 to 18 MV. The dose per pulse dependence was investigated. This was done by altering the source‐surface distance, field size, and wedge for photons. The off‐axis correction and effect of changing repetition rate were also investigated. A model was developed to fit the measured two‐dimensional diode correction factors. PACS number(s): 87.66.–a, 87.52.–g PMID:12777148
Wedge and spring assembly for securing coils in electromagnets and dynamoelectric machines
Lindner, Melvin; Cottingham, James G.
1996-03-12
A wedge and spring assembly for use in electromagnets or dynamoelectric machines having a housing with an axis therethrough and a plurality of coils supported on salient poles that extend radially inward from the housing toward the housing axis to define a plurality of interpole spaces. The wedge and spring assembly includes a nonmagnetic retainer spring and a nonmagnetic wedge. The retainer spring is formed to fit into one of the interpole spaces, and has juxtaposed ends defining between them a slit extending in a direction generally parallel to the housing axis. The wedge for insertion into the slit provides an outwardly directed force on respective portions of the juxtaposed ends to expand the slit so that respective portions of the retainer spring engage areas of the coils adjacent thereto, thereby resiliently holding the coils against their respective salient poles. The retainer spring is generally triangular shaped to fit within the interpole space, and the wedge is generally T-shaped.
Wedge and spring assembly for securing coils in electromagnets and dynamoelectric machines
Lindner, M.; Cottingham, J.G.
1996-03-12
A wedge and spring assembly for use in electromagnets or dynamoelectric machines is disclosed having a housing with an axis therethrough and a plurality of coils supported on salient poles that extend radially inward from the housing toward the housing axis to define a plurality of interpole spaces. The wedge and spring assembly includes a nonmagnetic retainer spring and a nonmagnetic wedge. The retainer spring is formed to fit into one of the interpole spaces, and has juxtaposed ends defining between them a slit extending in a direction generally parallel to the housing axis. The wedge for insertion into the slit provides an outwardly directed force on respective portions of the juxtaposed ends to expand the slit so that respective portions of the retainer spring engage areas of the coils adjacent thereto, thereby resiliently holding the coils against their respective salient poles. The retainer spring is generally triangular shaped to fit within the interpole space, and the wedge is generally T-shaped. 6 figs.
Kwun, Jun-Dae; Kim, Hee-June; Park, Jaeyoung; Park, Il-Hyung; Kyung, Hee-Soo
2017-01-01
The purpose of this study was to evaluate the usefulness of three-dimensional (3D) printed models for open wedge high tibial osteotomy (HTO) in porcine bone. Computed tomography (CT) images were obtained from 10 porcine knees and 3D imaging was planned using the 3D-Slicer program. The osteotomy line was drawn from the three centimeters below the medial tibial plateau to the proximal end of the fibular head. Then the osteotomy gap was opened until the mechanical axis line was 62.5% from the medial border along the width of the tibial plateau, maintaining the posterior tibial slope angle. The wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The open wedge HTO surgery was reproduced in porcine bone using the 3D-printed model and the osteotomy site was fixed with a plate. Accuracy of osteotomy and posterior tibial slope was evaluated after the osteotomy. The mean mechanical axis line on the tibial plateau was 61.8±1.5% from the medial tibia. There was no statistically significant difference (P=0.160). The planned and post-osteotomy correction wedge angles were 11.5±3.2° and 11.4±3.3°, and the posterior tibial slope angle was 11.2±2.2° pre-osteotomy and 11.4±2.5° post-osteotomy. There were no significant differences (P=0.854 and P=0.429, respectively). This study showed that good results could be obtained in high tibial osteotomy by using 3D printed models of porcine legs. Copyright © 2016 Elsevier B.V. All rights reserved.
Bito, Haruhiko; Takeuchi, Ryohei; Kumagai, Ken; Aratake, Masato; Saito, Izumi; Hayashi, Riku; Sasaki, Yohei; Aota, Yoichi; Saito, Tomoyuki
2009-04-01
Obtaining a correct postoperative limb alignment is an important factor in achieving a successful clinical outcome after an opening-wedge high tibial osteotomy (OWHTO). To better predict some of the aspects that impact upon the clinical outcomes following this procedure, including postoperative correction loss and over correction, we examined the changes in the frontal plane of the lower limb in a cohort of patients who had undergone OWHTO using radiography. Forty-two knees from 33 patients (23 cases of osteoarthritis and 10 of osteonecrosis) underwent a valgus realignment OWHTO procedure and were radiographically assessed for changes that occurred pre- and post-surgery. The mean femorotibial angle (FTA) was found to be 182.1 +/- 2.0 degrees (12 +/- 2.0 anatomical varus angulation) preoperatively and 169.6 +/- 2.4 degrees (10.4 +/- 2.4 anatomical valgus angulation) postoperatively. These measurements thus revealed significant changes in the weight bearing line ratio (WBL), femoral axis angle (FA), tibial axis angle (TA), tibia plateau angle (TP), tibia vara angle (TV) and talar tilt angle (TT) following OWHTO. In contrast, no significant change was found in the weight bearing line angle (WBLA) after these treatments. To assess the relationship between the correction angle and these indexes, 42 knees were divided into the following three groups according to the postoperative FTA; a normal correction group (168 degrees < or = FTA < or = 172 degrees ), an over-correction group (FTA < 168 degrees ), and an under-correction group (FTA > 172 degrees ). There were significant differences in the delta angle [DA; calculated as (pre FTA - post FTA) - (pre TV - post TV)] among each group of patients. Our results thus indicate a negative correlation between the DA and preoperative TA (R(2) = 0.148, p < 0.05). Hence, given that the correction errors in our patients appear to negatively correlate with the preoperative TA, postoperative malalignments are likely to be predictable prior to surgery.
Mechanical coupling for a rotor shaft assembly of dissimilar materials
Shi, Jun [Glastonbury, CT; Bombara, David [New Hartford, CT; Green, Kevin E [Broad Brook, CT; Bird, Connic [Rocky Hill, CT; Holowczak, John [South Windsor, CT
2009-05-05
A mechanical coupling for coupling a ceramic disc member to a metallic shaft includes a first wedge clamp and a second wedge clamp. A fastener engages a threaded end of a tie-bolt to sandwich the ceramic disc between the wedge clamps. An axial spring is positioned between the fastener and the second wedge clamp to apply an axial preload along the longitudinal axis. Another coupling utilizes a rotor shaft end of a metallic rotor shaft as one wedge clamp. Still another coupling includes a solid ceramic rotor disc with a multiple of tie-bolts radially displaced from the longitudinal axis to exert the preload on the solid ceramic rotor disc.
A possible mechanism for earthquakes found in the mantle wedge of the Nazca subduction zone
NASA Astrophysics Data System (ADS)
Warren, L. M.; Chang, Y.; Prieto, G. A.
2017-12-01
Beneath Colombia, the Cauca cluster of intermediate-depth earthquakes extends for 200 km along the trench (3.5°N-5.5°N, 77.0°W-75.3°W) and, with 58 earthquakes per year with local magnitude ML >= 2.5, has a higher rate of seismicity than the subduction zone immediately to the north or south. By precisely locating 433 cluster earthquakes from 1/2010-3/2014 with data from the Colombian National Seismic Network, we found that the earthquakes are located both in a continuous Nazca plate subducting at an angle of 33°-43° and in the overlying mantle wedge. The mantle wedge earthquakes (12% of the earthquakes) form two isolated 40-km-tall columns extending perpendicular to the subducting slab. Using waveform inversion, we computed focal mechanisms for 69 of the larger earthquakes. The focal mechanisms are variable, but the intraslab earthquakes are generally consistent with an in-slab extensional stress axis oriented 25° counterclockwise from the down-dip direction. We suggest that the observed mantle wedge earthquakes are the result of hydrofracture in a relatively cool mantle wedge. This segment of the Nazca Plate is currently subducting at a normal angle, but Wagner et al. (2017) suggested that a flat slab slowly developed in the region between 9-5.9 Ma and persisted until 4 Ma. During flat slab subduction, the overlying mantle wedge typically cools because it is cut off from mantle corner flow. After hydrous minerals in the slab dehydrate, the dehydrated fluid is expelled from the slab and migrates through the mantle wedge. If a cool mantle wedge remains today, fluid dehydrated from the slab may generate earthquakes by hydrofracture, with the mantle wedge earthquakes representing fluid migration pathways. Dahm's (2000) model of water-filled fracture propagation in the mantle wedge shows hydrofractures propagating normal to the subducting slab and extending tens of km into the mantle wedge, as we observe.
Changes in prescribed doses for the Seattle neutron therapy system
NASA Astrophysics Data System (ADS)
Popescu, A.
2008-06-01
From the beginning of the neutron therapy program at the University of Washington Medical Center, the neutron dose distribution in tissue has been calculated using an in-house treatment planning system called PRISM. In order to increase the accuracy of the absorbed dose calculations, two main improvements were made to the PRISM treatment planning system: (a) the algorithm was changed by the addition of an analytical expression of the central axis wedge factor dependence with field size and depth developed at UWMC. Older versions of the treatment-planning algorithm used a constant central axis wedge factor; (b) a complete newly commissioned set of measured data was introduced in the latest version of PRISM. The new version of the PRISM algorithm allowed for the use of the wedge profiles measured at different depths instead of one wedge profile measured at one depth. The comparison of the absorbed dose calculations using the old and the improved algorithm showed discrepancies mainly due to the missing central axis wedge factor dependence with field size and depth and due to the absence of the wedge profiles at depths different from 10 cm. This study concludes that the previously reported prescribed doses for neutron therapy should be changed.
Posterior tibial slope in medial opening-wedge high tibial osteotomy: 2-D versus 3-D navigation.
Yim, Ji Hyeon; Seon, Jong Keun; Song, Eun Kyoo
2012-10-01
Although opening-wedge high tibial osteotomy (HTO) is used to correct deformities, it can simultaneously alter tibial slope in the sagittal plane because of the triangular configuration of the proximal tibia, and this undesired change in tibial slope can influence knee kinematics, stability, and joint contact pressure. Therefore, medial opening-wedge HTO is a technically demanding procedure despite the use of 2-dimensional (2-D) navigation. The authors evaluated the posterior tibial slope pre- and postoperatively in patients who underwent navigation-assisted opening-wedge HTO and compared posterior slope changes for 2-D and 3-dimensional (3-D) navigation versions. Patients were randomly divided into 2 groups based on the navigation system used: group A (2-D guidance for coronal alignment; 17 patients) and group B (3-D guidance for coronal and sagittal alignments; 17 patients). Postoperatively, the mechanical axis was corrected to a mean valgus of 2.81° (range, 1°-5.4°) in group A and 3.15° (range, 1.5°-5.6°) in group B. A significant intergroup difference existed for the amount of posterior tibial slope change (Δ slope) pre- and postoperatively (P=.04).Opening-wedge HTO using navigation offers accurate alignment of the lower limb. In particular, the use of 3-D navigation results in significantly less change in the posterior tibial slope postoperatively than does the use of 2-D navigation. Accordingly, the authors recommend the use of 3-D navigation systems because they provide real-time intraoperative information about coronal, sagittal, and transverse axes and guide the maintenance of the native posterior tibial slope. Copyright 2012, SLACK Incorporated.
Eccentric correction for off-axis vision in central visual field loss.
Gustafsson, Jörgen; Unsbo, Peter
2003-07-01
Subjects with absolute central visual field loss use eccentric fixation and magnifying devices to utilize their residual vision. This preliminary study investigated the importance of an accurate eccentric correction of off-axis refractive errors to optimize the residual visual function for these subjects. Photorefraction using the PowerRefractor instrument was used to evaluate the ametropia in eccentric fixation angles. Methods were adapted for measuring visual acuity outside the macula using filtered optotypes from high-pass resolution perimetry. Optical corrections were implemented, and the visual function of subjects with central visual field loss was measured with and without eccentric correction. Of the seven cases reported, five experienced an improvement in visual function in their preferred retinal locus with eccentric refraction. The main result was that optical correction for better image quality on the peripheral retina is important for the vision of subjects with central visual field loss, objectively as well as subjectively.
NASA Technical Reports Server (NTRS)
Haguenauer, Pierre; Serabyn, Eugene; Bloemhof, Eric E.; Troy, Mitchell; Wallace, James K.; Koresko, Chris D.; Mennesson, Bertrand
2005-01-01
Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques because of the high difference between their respective fluxes. This led us to test a new coronagraphic approach based on the use of phase mask instead of dark occulting ones. Combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows imaging very close to the star. Calculations indicate that for a given ground-based on-axis telescope, use of such an off-axis coronagraph provides a near-neighbor detection capability superior to that of a traditional coronagraph utilizing the full telescope aperture. Setting up a laboratory experiment working in near infrared allowed us to demonstrate the principle of the method, and a rejection of 2000:1 has already been achieved.
Sun, Hao; Zhou, Lin; Li, Fengsheng; Duan, Jun
2017-02-01
Young active patients with medial knee osteoarthritis (OA) combined with varus leg alignment can be treated with high tibial osteotomy (HTO) to stop the progression of OA and avoid or postpone total knee arthroplasty (TKA). Closing-wedge osteotomy (CWO) and opening-wedge osteotomy (OWO) are the most commonly used osteotomy techniques. The purpose of this study was to compare the clinical and radiologic outcomes and complications between OWO and CWO. We retrospectively evaluated 23 studies including 17 clinical trials from published databases from their inception to May 2015. We evaluated the clinical outcomes including operation time, visual analog scale (VAS), maximal flexion, and hospital for special surgery knee (HSS) score. The radiologic outcomes included patellar height measured by posterior tibial slope angle, hip-knee-ankle (HKA) angle, femorotibial (FT) axis, and limb length. Complications recorded included the incidence of deep vein thrombosis (DVT), common peroneal nerve injury, opposite cortical fracture, etc. There were no differences in most of the clinical outcomes except the operation time. OWO increased the posterior slope angle and limb length, decreased the patellar height, and provided higher accuracy of correction. CWO led to a higher incidence of opposite cortical fracture. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Study on imaging spectrometer with smile and keystone eliminated
NASA Astrophysics Data System (ADS)
Zhang, Xiaolong; Yu, Kun; Zhang, Jun
2017-03-01
The formulas of image height in two-dimensional field about Gaussian and tilted imaging system of grating-based imaging spectrometer instrument (GISI) are deduced firstly, and the determined expressions of smile and keystone of GISI are obtained. It is proposed to correct the smile with off-axis lens, and the elimination effect of the smile is studied by means of spatial ray tracing. By controlling the degree of off-axis and the distribution of focal power of the off-axis lens, the long-wave infrared imaging spectrometer with well-eliminated smile and keystone is designed. The maximum of smile and keystone at working wavelengths in all fields of view are less than 8.57 μm and 13.33 μm, respectively.
Unsteady Newton-Busemann flow theory. I - Airfoils
NASA Technical Reports Server (NTRS)
Hui, W. H.; Tobak, M.
1981-01-01
Newtonian flow theory for unsteady flow at very high Mach numbers is completed by the addition of a centrifugal force correction to the impact pressures. The correction term is the unsteady counterpart of Busemann's centrifugal force correction to impact pressures in steady flow. For airfoils of arbitary shape, exact formulas for the unsteady pressure and stiffness and damping-in-pitch derivatives are obtained in closed form, which require only numerical quadratures of terms involving the airfoil shape. They are applicable to airfoils of arbitrary thickness having sharp or blunt leading edges. For wedges and thin airfoils these formulas are greatly simplified, and it is proved that the pitching motions of thin airfoils of convex shape and of wedges of arbitrary thickness are always dynamically stable according to Newton-Busemann theory. Leading-edge bluntness is shown to have a favorable effect on the dynamic stability; on the other hand, airfoils of concave shape tend toward dynamic instability over a range of axis positions if the surface curvature exceeds a certain limit. As a byproduct, it is also shown that a pressure formula recently given by Barron and Mandl for unsteady Newtonian flow over a pitching power-law shaped airfoil is erroneous and that their conclusion regarding the effect of pivot position on the dynamic stability is misleading.
NASA Astrophysics Data System (ADS)
van Eerten, Hendrik; Zhang, Weiqun; MacFadyen, Andrew
2010-10-01
Starting as highly relativistic collimated jets, gamma-ray burst outflows gradually slow down and become nonrelativistic spherical blast waves. Although detailed analytical solutions describing the afterglow emission received by an on-axis observer during both the early and late phases of the outflow evolution exist, a calculation of the received flux during the intermediate phase and for an off-axis observer requires either a more simplified analytical model or direct numerical simulations of the outflow dynamics. In this paper, we present light curves for off-axis observers covering the long-term evolution of the blast wave, calculated from a high-resolution two-dimensional relativistic hydrodynamics simulation using a synchrotron radiation model. We compare our results to earlier analytical work and calculate the consequence of the observer angle with respect to the jet axis both for the detection of orphan afterglows and for jet break fits to the observational data. We confirm earlier results in the literature finding that only a very small number of local type Ibc supernovae can harbor an orphan afterglow. For off-axis observers, the observable jet break can be delayed up to several weeks, potentially leading to overestimation of the beaming-corrected total energy. In addition we find that, when using our off-axis light curves to create synthetic Swift X-ray data, jet breaks are likely to remain hidden in the data.
Field experiment of 800× off-axis XR-Köhler concentrator module on a carousel tracker
NASA Astrophysics Data System (ADS)
Yamada, Noboru; Okamoto, Kazuya; Ijiro, Toshikazu; Suzuki, Takao; Maemura, Toshihiko; Kawaguchi, Takashi; Takahashi, Hiroshi; Sato, Takashi; Hernandez, Maikel; Benitez, Pablo; Chaves, Julio; Cvetkovic, Aleksandra; Vilaplana, Juan; Mohedano, Ruben; Mendes-Lopes, Joao; Miñano, Juan Carlos
2013-09-01
This paper presents the design and preliminary experimental results of a concentrator-type photovoltaic module based on a free-form off-axis 800×XR-Köhler concentrator. The off-axis XR-Köhler concentrator is one of the advanced concentrators that perform high concentration with a large acceptance angle and excellent irradiance uniformity on a solar cell. As a result of on-sun characterization of the unglazed single-cell unit test rig, the temperature-corrected DC module efficiency was 32.2% at 25 °C without an anti-reflective (AR) coating on the secondary optics, and the acceptance angle was more than ±1.0°. In addition, the non-corrected DC efficiency of an individual cell in a glazed 8-cell unit module mounted on a carousel tracking system was measured. The individual efficiency deviated in the range of 24.3-27.4%, owing to the mirror shape and alignment errors. The resultant series-connected efficiency was approximately 25% at direct normal irradiation (DNI) of 770 W/m2.
Achromatic self-referencing interferometer
Feldman, Mark
1994-01-01
A self-referencing Mach-Zehnder interferometer for accurately measuring laser wavefronts over a broad wavelength range (for example, 600 nm to 900 nm). The apparatus directs a reference portion of an input beam to a reference arm and a measurement portion of the input beam to a measurement arm, recombines the output beams from the reference and measurement arms, and registers the resulting interference pattern ("first" interferogram) at a first detector. Optionally, subportions of the measurement portion are diverted to second and third detectors, which respectively register intensity and interferogram signals which can be processed to reduce the first interferogram's sensitivity to input noise. The reference arm includes a spatial filter producing a high quality spherical beam from the reference portion, a tilted wedge plate compensating for off-axis aberrations in the spatial filter output, and mirror collimating the radiation transmitted through the tilted wedge plate. The apparatus includes a thermally and mechanically stable baseplate which supports all reference arm optics, or at least the spatial filter, tilted wedge plate, and the collimator. The tilted wedge plate is mounted adjustably with respect to the spatial filter and collimator, so that it can be maintained in an orientation in which it does not introduce significant wave front errors into the beam propagating through the reference arm. The apparatus is polarization insensitive and has an equal path length configuration enabling measurement of radiation from broadband as well as closely spaced laser line sources.
NASA Astrophysics Data System (ADS)
Keall, Paul; Arief, Isti; Shamas, Sofia; Weiss, Elisabeth; Castle, Steven
2008-05-01
Whole brain radiation therapy (WBRT) is the standard treatment for patients with brain metastases, and is often used in conjunction with stereotactic radiotherapy for patients with a limited number of brain metastases, as well as prophylactic cranial irradiation. The use of open fields (conventionally used for WBRT) leads to higher doses to the brain periphery if dose is prescribed to the brain center at the largest lateral radius. These dose variations potentially compromise treatment efficacy and translate to increased side effects. The goal of this research was to design and construct a 3D 'brain wedge' to compensate dose heterogeneities in WBRT. Radiation transport theory was invoked to calculate the desired shape of a wedge to achieve a uniform dose distribution at the sagittal plane for an ellipsoid irradiated medium. The calculations yielded a smooth 3D wedge design to account for the missing tissue at the peripheral areas of the brain. A wedge was machined based on the calculation results. Three ellipsoid phantoms, spanning the mean and ± two standard deviations from the mean cranial dimensions were constructed, representing 95% of the adult population. Film was placed at the sagittal plane for each of the three phantoms and irradiated with 6 MV photons, with the wedge in place. Sagittal plane isodose plots for the three phantoms demonstrated the feasibility of this wedge to create a homogeneous distribution with similar results observed for the three phantom sizes, indicating that a single wedge may be sufficient to cover 95% of the adult population. The sagittal dose is a reasonable estimate of the off-axis dose for whole brain radiation therapy. Comparing the dose with and without the wedge the average minimum dose was higher (90% versus 86%), the maximum dose was lower (107% versus 113%) and the dose variation was lower (one standard deviation 2.7% versus 4.6%). In summary, a simple and effective 3D wedge for whole brain radiotherapy has been developed. The wedge gives a more uniform dose distribution than commonly used techniques. Further development and shape optimization may be necessary prior to clinical implementation.
Jensen, Jonas; Olesen, Jacob Bjerring; Stuart, Matthias Bo; Hansen, Peter Møller; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt
2016-08-01
A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice. Copyright © 2016 Elsevier B.V. All rights reserved.
Orzó, László
2015-06-29
Retrieving correct phase information from an in-line hologram is difficult as the object wave field and the diffractions of the zero order and the conjugate object term overlap. The existing iterative numerical phase retrieval methods are slow, especially in the case of high Fresnel number systems. Conversely, the reconstruction of the object wave field from an off-axis hologram is simple, but due to the applied spatial frequency filtering the achievable resolution is confined. Here, a new, high-speed algorithm is introduced that efficiently incorporates the data of an auxiliary off-axis hologram in the phase retrieval of the corresponding in-line hologram. The efficiency of the introduced combined phase retrieval method is demonstrated by simulated and measured holograms.
The use of sternal wedge osteotomy in pectus surgery: when is it necessary?
Kara, Murat; Gundogdu, Ahmet Gokhan; Kadioglu, Salih Zeki; Cayirci, Ertug Can; Taskin, Necati
2016-09-01
The Ravitch procedure is a well-established surgical procedure for correction of chest wall deformities. Sternal wedge osteotomy is an important part of this procedure. We studied the incidence of wedge osteotomy with respect to the type of chest wall deformity in patients undergoing surgical correction with the use of a recently developed chest wall stabilization system. A total of 47 patients, 39 (83%) male and 8 (17%) female with a mean age of 14.9 ± 2.1 years, underwent the Ravitch procedure. Twenty-four (51.1%) had pectus carinatum, 19 (40.4%) had pectus excavatum, and 4 (8.5%) had pectus arcuatum. A conventional or oblique sternal wedge osteotomy was performed as indicated, followed by chest wall stabilization using the MedXpert system. Of the 47 patients, 27 (57.4%) had a sternal wedge osteotomy. All cases of pectus arcuatum and redo cases underwent sternal wedge osteotomy. Pectus excavatum cases tended to have a greater incidence of wedge osteotomy compared to pectus carinatum cases (68.4% vs. 41.7%, p = 0.052). Patients with more resected ribs had a greater rate of wedge osteotomy (63.4%) compared to those with fewer resected ribs (16.7%, p = 0.043). A sternal wedge osteotomy is more commonly performed in patients with pectus excavatum compared to those with pectus carinatum. All redo and pectus arcuatum cases need a wedge osteotomy for proper correction. Wedge osteotomy is very likely in more aggressive corrections with more rib resections. © The Author(s) 2016.
Porous Titanium Wedges in Lateral Column Lengthening for Adult-Acquired Flatfoot Deformity.
Moore, Spencer H; Carstensen, S Evan; Burrus, M Tyrrell; Cooper, Truitt; Park, Joseph S; Perumal, Venkat
2017-10-01
Lateral column lengthening (LCL) is a common procedure for reconstruction of stage II flexible adult-acquired flatfoot deformity (AAFD). The recent development of porous titanium wedges for this procedure provides an alternative to allograft and autograft. The purpose of this study was to report radiographic and clinical outcomes achieved with porous titanium wedges in LCL. A retrospective analysis of 34 feet in 30 patients with AAFD that received porous titanium wedges for LCL from January 2011 to October 2014. Deformity correction was assessed using both radiographic and clinical parameters. Radiographic correction was assessed using the lateral talo-first metatarsal angle, the talonavicular uncoverage percentage, and the first metatarsocuneiform height. The hindfoot valgus angle was measured. Patients were followed from a minimum of 6 months up to 4 years (mean 16.1 months). Postoperative radiographs demonstrated significant correction in all 3 radiographic criteria and the hindfoot valgus angle. We had no cases of nonunion, no wedge migration, and no wedges have been removed to date. The most common complication was calcaneocuboid joint pain (14.7%). Porous titanium wedges in LCL can achieve good radiographic and clinical correction of AAFD with a low rate of nonunion and other complications. Level IV: Case series.
Achromatic self-referencing interferometer
Feldman, M.
1994-04-19
A self-referencing Mach-Zehnder interferometer is described for accurately measuring laser wavefronts over a broad wavelength range (for example, 600 nm to 900 nm). The apparatus directs a reference portion of an input beam to a reference arm and a measurement portion of the input beam to a measurement arm, recombines the output beams from the reference and measurement arms, and registers the resulting interference pattern ([open quotes]first[close quotes] interferogram) at a first detector. Optionally, subportions of the measurement portion are diverted to second and third detectors, which respectively register intensity and interferogram signals which can be processed to reduce the first interferogram's sensitivity to input noise. The reference arm includes a spatial filter producing a high quality spherical beam from the reference portion, a tilted wedge plate compensating for off-axis aberrations in the spatial filter output, and mirror collimating the radiation transmitted through the tilted wedge plate. The apparatus includes a thermally and mechanically stable baseplate which supports all reference arm optics, or at least the spatial filter, tilted wedge plate, and the collimator. The tilted wedge plate is mounted adjustably with respect to the spatial filter and collimator, so that it can be maintained in an orientation in which it does not introduce significant wave front errors into the beam propagating through the reference arm. The apparatus is polarization insensitive and has an equal path length configuration enabling measurement of radiation from broadband as well as closely spaced laser line sources. 3 figures.
Hermida, Juan C; Flores-Hernandez, Cesar; Hoenecke, Heinz R; D'Lima, Darryl D
2014-03-01
This study undertook a computational analysis of a wedged glenoid component for correction of retroverted glenoid arthritic deformity to determine whether a wedge-shaped glenoid component design with a built-in correction for version reduces excessive stresses in the implant, cement, and glenoid bone. Recommendations for correcting retroversion deformity are asymmetric reaming of the anterior glenoid, bone grafting of the posterior glenoid, or a glenoid component with posterior augmentation. Eccentric reaming has the disadvantages of removing normal bone, reducing structural support for the glenoid component, and increasing the risk of bone perforation by the fixation pegs. Bone grafting to correct retroverted deformity does not consistently generate successful results. Finite element models of 2 scapulae models representing a normal and an arthritic retroverted glenoid were implanted with a standard glenoid component (in retroversion or neutral alignment) or a wedged component. Glenohumeral forces representing in vivo loading were applied and stresses and strains computed in the bone, cement, and glenoid component. The retroverted glenoid components generated the highest compressive stresses and decreased cyclic fatigue life predictions for trabecular bone. Correction of retroversion by the wedged glenoid component significantly decreased stresses and predicted greater bone fatigue life. The cement volume estimated to survive 10 million cycles was the lowest for the retroverted components and the highest for neutrally implanted glenoid components and for wedged components. A wedged glenoid implant is a viable option to correct severe arthritic retroversion, reducing the need for eccentric reaming and the risk for implant failure. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques.
Iorio, R; Pagnottelli, M; Vadalà, A; Giannetti, S; Di Sette, P; Papandrea, P; Conteduca, F; Ferretti, A
2013-01-01
The purpose of our study was to compare clinical and radiological results of two groups of patients treated for medial compartment osteoarthritis of the knee with either conventional or computer-assisted open-wedge high tibial osteotomy (HTO). Goals of surgical treatment were a correction of the mechanical axis between 2° and 6° of valgus and a modification of posterior tibial slope between -2° and +2°. Twenty-four patients (27 knees) affected by varus knee deformity and operated with HTO were prospectively followed-up. They were randomly divided in two groups, A (11 patients, conventional treatment) and B (13 patients, navigated treatment). The American Knee Society Score and the Modified Cincinnati Rating System Questionnaire were used for clinical assessment. All patients were radiologically evaluated with a comparative lower limb weight-bearing digital radiograph, a standard digital anteroposterior, a latero-lateral radiograph of the knee, and a Rosenberg view. Patients were followed-up at a mean of 39 months. Clinical evaluation showed no statistical difference (n.s.) between the two groups. Radiological results showed an 86% reproducibility in achieving a mechanical axis of 182°-186° in group B compared to a 23% in group A (p = 0.0392); furthermore, in group B, we achieved a modification of posterior tibial slope between -2° and +2° in 100% of patients, while in group A, this goal was achieved only in 24% of cases (p = 0.0021). High tibial osteotomy with navigator is more accurate and reproducible in the correction of the deformity compared to standard technique. Therapeutic study, Level II.
Photon collider: a four-channel autoguider solution
NASA Astrophysics Data System (ADS)
Hygelund, John C.; Haynes, Rachel; Burleson, Ben; Fulton, Benjamin J.
2010-07-01
The "Photon Collider" uses a compact array of four off axis autoguider cameras positioned with independent filtering and focus. The photon collider is two way symmetric and robustly mounted with the off axis light crossing the science field which allows the compact single frame construction to have extremely small relative deflections between guide and science CCDs. The photon collider provides four independent guiding signals with a total of 15 square arc minutes of sky coverage. These signals allow for simultaneous altitude, azimuth, field rotation and focus guiding. Guide cameras read out without exposure overhead increasing the tracking cadence. The independent focus allows the photon collider to maintain in focus guide stars when the main science camera is taking defocused exposures as well as track for telescope focus changes. Independent filters allow auto guiding in the science camera wavelength bandpass. The four cameras are controlled with a custom web services interface from a single Linux based industrial PC, and the autoguider mechanism and telemetry is built around a uCLinux based Analog Devices BlackFin embedded microprocessor. Off axis light is corrected with a custom meniscus correcting lens. Guide CCDs are cooled with ethylene glycol with an advanced leak detection system. The photon collider was built for use on Las Cumbres Observatory's 2 meter Faulks telescopes and currently used to guide the alt-az mount.
Astigmatism-corrected echelle spectrometer using an off-the-shelf cylindrical lens.
Fu, Xiao; Duan, Fajie; Jiang, Jiajia; Huang, Tingting; Ma, Ling; Lv, Changrong
2017-10-01
As a special kind of spectrometer with the Czerny-Turner structure, the echelle spectrometer features two-dimensional dispersion, which leads to a complex astigmatic condition. In this work, we propose an optical design of astigmatism-corrected echelle spectrometer using an off-the-shelf cylindrical lens. The mathematical model considering astigmatism introduced by the off-axis mirrors, the echelle grating, and the prism is established. Our solution features simplified calculation and low-cost construction, which is capable of overall compensation of the astigmatism in a wide spectral range (200-600 nm). An optical simulation utilizing ZEMAX software, astigmatism assessment based on Zernike polynomials, and an instrument experiment is implemented to validate the effect of astigmatism correction. The results demonstrated that astigmatism of the echelle spectrometer was corrected to a large extent, and high spectral resolution better than 0.1 nm was achieved.
Hua, Wen-Bin; Zhang, Yu-Kun; Gao, Yong; Liu, Xian-Zhe; Yang, Shu-Hua; Wu, Xing-Huo; Wang, Jing; Yang, Cao
2017-07-15
Retrospective analysis of clinical records. To assess and compare the improvement in sagittal balance after one- or two-level closing wedge osteotomy for correcting thoracolumbar kyphosis secondary to ankylosing spondylitis (AS). Closing wedge osteotomy represents a common approach to correct kyphosis in AS. Although several reports have described the outcomes of one- or two-level closing wedge osteotomy in terms of sagittal parameters, data comparing the outcomes of these procedures are scarce. Between January 2010 and December 2014, 22 patients with AS underwent closing wedge osteotomy (one-level, 12 patients; two-level, 10 patients) for correcting thoracolumbar kyphosis (mean follow-up, 24.8 months; range, 12-60 months). Preoperative and postoperative chin-brow vertical angle, and the sagittal parameters of the vertebral osteotomy segment were documented and compared. Perioperative and postoperative complications were also recorded. The chin-brow vertical angle improved significantly, from 55.0° ± 27.3° to 4.7° ± 4.9° and from 38.2° ± 14.9° to 3.2° ± 5.4° in the one-level and two-level groups, respectively. The total correction (thoracic kyphosis and lumbar lordosis) was 32.8° ± 18.2° and 53.7° ± 9.4° in the one-level and two-level groups, respectively. No death, complete paralysis, or vascular complications occurred during the procedure, but cerebrospinal fluid leak was noted in one and two patients from the one-level and two-level groups, respectively. A distal pedicle screw adjacent to the osteotomy segment became loose during surgery in one patient (one-level group). Postoperatively, no transient neurological deficit, infection, delay union, or loosening or breaking of the internal fixation devices was observed. Osteotomy site fusion was achieved in all patients, and the Oswestry Disability Index scores improved significantly. Closing wedge osteotomy is effective and safe for correcting thoracolumbar kyphosis in patients with AS. Significant correction and improvement in all sagittal parameters were noted in both groups, but two-level closing wedge osteotomy provided better correction. 3.
Phase derivative method for reconstruction of slightly off-axis digital holograms.
Guo, Cheng-Shan; Wang, Ben-Yi; Sha, Bei; Lu, Yu-Jie; Xu, Ming-Yuan
2014-12-15
A phase derivative (PD) method is proposed for reconstruction of off-axis holograms. In this method, a phase distribution of the tested object wave constrained within 0 to pi radian is firstly worked out by a simple analytical formula; then it is corrected to its right range from -pi to pi according to the sign characteristics of its first-order derivative. A theoretical analysis indicates that this PD method is particularly suitable for reconstruction of slightly off-axis holograms because it only requires the spatial frequency of the reference beam larger than spatial frequency of the tested object wave in principle. In addition, because the PD method belongs to a pure local method with no need of any integral operation or phase shifting algorithm in process of the phase retrieval, it could have some advantages in reducing computer load and memory requirements to the image processing system. Some experimental results are given to demonstrate the feasibility of the method.
Scott, JoAnna M; deCamp, Allan; Juraska, Michal; Fay, Michael P; Gilbert, Peter B
2017-04-01
Stepped wedge designs are increasingly commonplace and advantageous for cluster randomized trials when it is both unethical to assign placebo, and it is logistically difficult to allocate an intervention simultaneously to many clusters. We study marginal mean models fit with generalized estimating equations for assessing treatment effectiveness in stepped wedge cluster randomized trials. This approach has advantages over the more commonly used mixed models that (1) the population-average parameters have an important interpretation for public health applications and (2) they avoid untestable assumptions on latent variable distributions and avoid parametric assumptions about error distributions, therefore, providing more robust evidence on treatment effects. However, cluster randomized trials typically have a small number of clusters, rendering the standard generalized estimating equation sandwich variance estimator biased and highly variable and hence yielding incorrect inferences. We study the usual asymptotic generalized estimating equation inferences (i.e., using sandwich variance estimators and asymptotic normality) and four small-sample corrections to generalized estimating equation for stepped wedge cluster randomized trials and for parallel cluster randomized trials as a comparison. We show by simulation that the small-sample corrections provide improvement, with one correction appearing to provide at least nominal coverage even with only 10 clusters per group. These results demonstrate the viability of the marginal mean approach for both stepped wedge and parallel cluster randomized trials. We also study the comparative performance of the corrected methods for stepped wedge and parallel designs, and describe how the methods can accommodate interval censoring of individual failure times and incorporate semiparametric efficient estimators.
Greer, Peter B; Vial, Philip; Oliver, Lyn; Baldock, Clive
2007-11-01
The aim of this work was to experimentally determine the difference in response of an amorphous silicon (a-Si) electronic portal imaging device (EPID) to the open and multileaf collimator (MLC) transmitted beam components of intensity modulated radiation therapy (IMRT) beams. EPID dose response curves were measured for open and MLC transmitted (MLCtr) 10 x 10 cm2 beams at central axis and with off axis distance using a shifting field technique. The EPID signal was obtained by replacing the flood-field correction with a pixel sensitivity variation matrix correction. This signal, which includes energy-dependent response, was then compared to ion-chamber measurements. An EPID calibration method to remove the effect of beam energy variations on EPID response was developed for IMRT beams. This method uses the component of open and MLCtr fluence to an EPID pixel calculated from the MLC delivery file and applies separate radially dependent calibration factors for each component. The calibration procedure does not correct for scatter differences between ion chamber in water measurements and EPID response; these must be accounted for separately with a kernel-based approach or similar method. The EPID response at central axis for the open beam was found to be 1.28 +/- 0.03 of the response for the MLCtr beam, with the ratio increasing to 1.39 at 12.5 cm off axis. The EPID response to MLCtr radiation did not change with off-axis distance. Filtering the beam with copper plates to reduce the beam energy difference between open and MLCtr beams was investigated; however, these were not effective at reducing EPID response differences. The change in EPID response for uniform sliding window IMRT beams with MLCtr dose components from 0.3% to 69% was predicted to within 2.3% using the separate EPID response calibration factors for each dose component. A clinical IMRT image calibrated with this method differed by nearly 30% in high MLCtr regions from an image calibrated with an open beam calibration factor only. Accounting for the difference in EPID response to open and MLCtr radiation should improve IMRT dosimetry with a-Si EPIDs.
[Distal femoral osteotomy using a lateral opening wedge technique].
Feucht, M J; Mehl, J; Forkel, P; Imhoff, A B; Hinterwimmer, S
2017-08-01
To shift the weight-bearing axis of the lower limb medially by opening a lateral-based metaphyseal osteotomy at the distal femur. Femoral-based valgus malalignment and symptomatic lateral unicompartimental osteoarthritis, lateral hyperpression syndrome, cartilage therapy of the lateral compartment, lateral meniscal replacement/transplantation, medial instability with valgus thrust, reconstruction of the medial collateral ligament, patellar instability and/or maltracking. Advanced cartilage damage (>grade 2) or subtotal meniscal loss of the medial compartment, age >65 years (relative), nicotine abuse, body mass index >30, flexion contracture >25°, corrections with a wedge base >10 mm in case of congenital deformities, inflammatory or septic arthritis, severe osteoporosis. Lateral approach to the distal femur; biplanar osteotomy (frontal + axial osteotomy), gradual opening of the osteotomy, osteotomy fixation with a locking plate. Free range of motion. Partial weight bearing with 20 kg for 2 weeks, followed by progressive weight bearing thereafter. Mean improvement of knee scores from 20-30 points and mean 10-year survival rate of 80% in patients with lateral unicompartimental osteoarthritis. Mean complication rate of 9%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerns, James R.; Followill, David S.; Imaging and Radiation Oncology Core-Houston, The University of Texas Health Science Center-Houston, Houston, Texas
Purpose: To compare radiation machine measurement data collected by the Imaging and Radiation Oncology Core at Houston (IROC-H) with institutional treatment planning system (TPS) values, to identify parameters with large differences in agreement; the findings will help institutions focus their efforts to improve the accuracy of their TPS models. Methods and Materials: Between 2000 and 2014, IROC-H visited more than 250 institutions and conducted independent measurements of machine dosimetric data points, including percentage depth dose, output factors, off-axis factors, multileaf collimator small fields, and wedge data. We compared these data with the institutional TPS values for the same points bymore » energy, class, and parameter to identify differences and similarities using criteria involving both the medians and standard deviations for Varian linear accelerators. Distributions of differences between machine measurements and institutional TPS values were generated for basic dosimetric parameters. Results: On average, intensity modulated radiation therapy–style and stereotactic body radiation therapy–style output factors and upper physical wedge output factors were the most problematic. Percentage depth dose, jaw output factors, and enhanced dynamic wedge output factors agreed best between the IROC-H measurements and the TPS values. Although small differences were shown between 2 common TPS systems, neither was superior to the other. Parameter agreement was constant over time from 2000 to 2014. Conclusions: Differences in basic dosimetric parameters between machine measurements and TPS values vary widely depending on the parameter, although agreement does not seem to vary by TPS and has not changed over time. Intensity modulated radiation therapy–style output factors, stereotactic body radiation therapy–style output factors, and upper physical wedge output factors had the largest disagreement and should be carefully modeled to ensure accuracy.« less
NASA Technical Reports Server (NTRS)
Roche, A. E.; Forney, P. B.; Morrow, H. E.; Anapol, M.
1983-01-01
A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.
Design of a CGH corrected calibration objective for the AO system at the Large Binocular Telescope
NASA Astrophysics Data System (ADS)
Schwab, Christian; Rakich, Andrew; Peter, Diethard; Aigner, Simon
2010-08-01
We describe the optical design of a calibration unit for the off-axis laser guide stars at the Large Binocular Telescope's ARGOS facility. Artificial stars with the desired wavefront are created using a computer generated hologram.
WE-AB-204-10: Evaluation of a Novel Dedicated Breast PET System (Mammi-PET)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Z; Swanson, T; O’Connor, M
2015-06-15
Purpose: To evaluate the performance characteristics of a novel dedicated breast PET system (Mammi-PET, Oncovision). The system has 2 detector rings giving axial/transaxial field of view of 8/17 cm. Each ring consists of 12 monolithic LYSO modules coupled to PSPMTs. Methods: Uniformity, sensitivity, energy and spatial resolution were measured according to NEMA standards. Count rate performance was investigated using a source of F-18 (1384uCi) decayed over 5 half-lives. A prototype PET phantom was imaged for 20 min to evaluate image quality, recovery coefficients and partial volume effects. Under an IRB-approved protocol, 11 patients who just underwent whole body PET/CT examsmore » were imaged prone with the breast pendulant at 5–10 minutes/breast. Image quality was assessed with and without scatter/attenuation correction and using different reconstruction algorithms. Results: Integral/differential uniformity were 9.8%/6.0% respectively. System sensitivity was 2.3% on axis, 2.2% and 2.8% at 3.8 cm and 7.8 cm off-axis. Mean energy resolution of all modules was 23.3%. Spatial resolution (FWHM) was 1.82 mm and 2.90 mm on axis and 5.8 cm off axis. Three cylinders (14 mm diameter) in the PET phantom were filled with activity concentration ratios of 4:1, 3:1, and 2:1 relative to the background. Measured cylinder to background ratios were 2.6, 1.8 and 1.5 (without corrections) and 3.6, 2.3 and 1.5 (with attenuation/scatter correction). Five cylinders (14, 10, 6, 4 and 2 mm diameter) each with an activity ratio of 4:1 were measured and showed recovery coefficients of 1, 0.66, 0.45, 0.18 and 0.18 (without corrections), and 1, 0.53, 0.30, 0.13 and 0 (with attenuation/scatter correction). Optimal phantom image quality was obtained with 3D MLEM algorithm, >20 iterations and without attenuation/scatter correction. Conclusion: The MAMMI system demonstrated good performance characteristics. Further work is needed to determine the optimal reconstruction parameters for qualitative and quantitative applications.« less
Aspheric figure generation using feedback from an infrared phase-shifting interferometer.
NASA Astrophysics Data System (ADS)
Stahl, H. P.; Ketelsen, D.
This paper discusses the usefulness of the infrared phase-shifting interferometric system for providing figure correcting feedback to the optician during the generation of the off-axis parabolic segments and how it is affected by the surface roughness produced by each generator tool.
Electron acceleration by a tightly focused Hermite-Gaussian beam: higher-order corrections
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao Zhiguo; Institute of Laser Physics and Chemistry, Sichuan University, Chengdu 610064; Yang Dangxiao
2008-03-15
Taking the TEM{sub 1,0}-mode Hermite-Gaussian (H-G) beam as a numerical calculation example, and based on the method of the perturbation series expansion, the higher-order field corrections of H-G beams are derived and used to study the electron acceleration by a tightly focused H-G beam in vacuum. For the case of the off-axis injection the field corrections to the terms of order f{sup 3} (f=1/kw{sub 0}, k and w{sub 0} being the wavenumber and waist width, respectively) are considered, and for the case of the on-axis injection the contributions of the terms of higher orders are negligible. By a suitable optimizationmore » of injection parameters the energy gain in the giga-electron-volt regime can be achieved.« less
Locking mechanism for indexing device
Lindemeyer, Carl W.
1984-01-01
Disclosed is a locking mechanism for an indexing spindle. A conventional r gear having outwardly extending teeth is affixed to the spindle. Also included is a rotatably mounted camshaft whose axis is arranged in skewed relationship with the axis of the spindle. A disk-like wedge having opposing camming surfaces is eccentrically mounted on the camshaft. As the camshaft is rotated, the camming surfaces of the disc-like member are interposed between adjacent gear teeth with a wiping action that wedges the disc-like member between the gear teeth. A zero backlash engagement between disc-like member and gear results, with the engagement having a high mechanical advantage so as to effectively lock the spindle against bidirectional rotation.
Sadek, Ahmed F; Osman, Mohammed K; Laklok, Mohamed A
2016-10-01
The aim of this study was to assess the effect of degree of anterior translation of the distal tibial fragment after lateral closing wedge high tibial osteotomy in patients having combined knee medial compartmental and patellofemoral osteoarthritis. A retrospective study was conducted on 64 patients who were operated on for combined knee medial compartmental and patellofemoral osteoarthritis, by lateral closing wedge high tibial osteotomy with anterior translation of the distal tibial fragment. They were divided into two groups; Group I comprising 32 patients (34 knees, mean age of 51.4±7years) whose degree of anterior translation was <1cm and Group II comprising 32 patients (33 knees, mean age of 52.2±8.3years) whose degree of anterior translation was >1.5cm. The final assessment was performed via: visual analog scale, postoperative Knee Society clinical rating system function score, active range of motion, time to union, degree of correction of mechanical axis, posterior tibial slope, and Insall-Salvati ratio. Group II patients exhibited statistically superior mean postoperative score and better return to their work than Group I (P=0.013, 0.076, respectively). Both groups showed statistically significant differences between the preoperative and postoperative evaluation parameters (P<0.001). The posterior tibial slope was decreased in both groups but with no significant difference (P=0.527). Lateral closing wedge high tibial osteotomy combined with anterior translation of the distal tibial fragment more than 1.5cm achieved significantly better postoperative functional knee score. Both groups exhibited comparatively decreased posterior tibial slope. Copyright © 2016 Elsevier B.V. All rights reserved.
Ravinsky, Robert A.; Ouellet, Jean-Albert; Brodt, Erika D.; Dettori, Joseph R.
2013-01-01
Study Design Systematic review. Study Rationale To seek out and assess the best quality evidence available comparing opening wedge osteotomy (OWO) and closing wedge osteotomy (CWO) in patients with ankylosing spondylitis to determine whether their results differ with regard to several different subjective and objective outcome measures. Objective The aim of this study is to determine whether there is a difference in subjective and objective outcomes when comparing CWO and OWO in patients with ankylosing spondylitis suffering from clinically significant thoracolumbar kyphosis with respect to quality-of-life assessments, complication risks, and the amount of correction of the spine achieved at follow-up. Methods A systematic review was undertaken of articles published up to July 2012. Electronic databases and reference lists of key articles were searched to identify studies comparing effectiveness and safety outcomes between adult patients with ankylosing spondylitis who received closing wedge versus opening wedge osteotomies. Studies that included pediatric patients, polysegmental osteotomies, or revision procedures were excluded. Two independent reviewers assessed the strength of evidence using the GRADE criteria and disagreements were resolved by consensus. Results From a total of 67 possible citations, 4 retrospective cohorts (class of evidence III) met our inclusion criteria and form the basis for this report. No differences in Oswestry Disability Index, visual analog scale for pain, Scoliosis Research Society (SRS)-24 score, SRS-22 score, and patient satisfaction were reported between the closing and opening wedge groups across two studies. Regarding radiological outcomes following closing versus opening osteotomies, mean change in sagittal vertical axis ranged from 8.9 to 10.8 cm and 8.0 to 10.9 cm, respectively, across three studies; mean change in lumbar lordosis ranged from 36 to 47 degrees and 19 to 41 degrees across four studies; and mean change in global kyphosis ranged from 38 to 40 degrees and 28 to 35 degrees across two studies. Across all studies, overall complication risks ranged from 0 to 16.7% following CWO and from 0 to 23.6% following OWO. Conclusion No statistically significant differences were seen in patient-reported or radiographic outcomes between CWO and OWO in any study. The risks of dural tear, neurological injury, and reoperation were similar between groups. Blood loss was greater in the closing wedge compared with the opening wedge group, while the risk of paralytic ileus was less. The overall strength of evidence for the conclusions is low. PMID:24436696
Wegener, Sonja; Sauer, Otto A
2018-02-01
Different detector properties will heavily affect the results of off-axis measurements outside of radiation fields, where a different energy spectrum is encountered. While a diode detector would show a high spatial resolution, it contains high atomic number elements, which lead to perturbations and energy-dependent response. An ionization chamber, on the other hand, has a much smaller energy dependence, but shows dose averaging over its larger active volume. We suggest a way to obtain spatial energy response corrections of a detector independent of its volume effect for profiles of arbitrary fields by using a combination of two detectors. Measurements were performed at an Elekta Versa HD accelerator equipped with an Agility MLC. Dose profiles of fields between 10 × 4 cm² and 0.6 × 0.6 cm² were recorded several times, first with different small-field detectors (unshielded diode 60012 and stereotactic field detector SFD, microDiamond, EDGE, and PinPoint 31006) and then with a larger volume ionization chamber Semiflex 31010 for different photon beam qualities of 6, 10, and 18 MV. Correction factors for the small-field detectors were obtained from the readings of the respective detector and the ionization chamber using a convolution method. Selected profiles were also recorded on film to enable a comparison. After applying the correction factors to the profiles measured with different detectors, agreement between the detectors and with profiles measured on EBT3 film was improved considerably. Differences in the full width half maximum obtained with the detectors and the film typically decreased by a factor of two. Off-axis correction factors outside of a 10 × 1 cm² field ranged from about 1.3 for the EDGE diode about 10 mm from the field edge to 0.7 for the PinPoint 31006 25 mm from the field edge. The microDiamond required corrections comparable in size to the Si-diodes and even exceeded the values in the tail region of the field. The SFD was found to require the smallest correction. The corrections typically became larger for higher energies and for smaller field sizes. With a combination of two detectors, experimentally derived correction factors can be obtained. Application of those factors leads to improved agreement between the measured profiles and those recorded on EBT3 film. The results also complement so far only Monte Carlo-simulated values for the off-axis response of different detectors. © 2017 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mizuno, Hideyuki, E-mail: h-mizuno@nirs.go.jp; Fukumura, Akifumi; Fukahori, Mai
Purpose: The purpose of this study was to obtain a set of correction factors of the radiophotoluminescent glass dosimeter (RGD) output for field size changes and wedge insertions. Methods: Several linear accelerators were used for irradiation of the RGDs. The field sizes were changed from 5 × 5 cm to 25 × 25 cm for 4, 6, 10, and 15 MV x-ray beams. The wedge angles were 15°, 30°, 45°, and 60°. In addition to physical wedge irradiation, nonphysical (dynamic/virtual) wedge irradiations were performed. Results: The obtained data were fitted with a single line for each energy, and correction factorsmore » were determined. Compared with ionization chamber outputs, the RGD outputs gradually increased with increasing field size, because of the higher RGD response to scattered low-energy photons. The output increase was about 1% per 10 cm increase in field size, with a slight difference dependent on the beam energy. For both physical and nonphysical wedged beam irradiation, there were no systematic trends in the RGD outputs, such as monotonic increase or decrease depending on the wedge angle change if the authors consider the uncertainty, which is approximately 0.6% for each set of measured points. Therefore, no correction factor was needed for all inserted wedges. Based on this work, postal dose audits using RGDs for the nonreference condition were initiated in 2010. The postal dose audit results between 2010 and 2012 were analyzed. The mean difference between the measured and stated doses was within 0.5% for all fields with field sizes between 5 × 5 cm and 25 × 25 cm and with wedge angles from 15° to 60°. The standard deviations (SDs) of the difference distribution were within the estimated uncertainty (1SD) except for the 25 × 25 cm field size data, which were not reliable because of poor statistics (n = 16). Conclusions: A set of RGD output correction factors was determined for field size changes and wedge insertions. The results obtained from recent postal dose audits were analyzed, and the mean differences between the measured and stated doses were within 0.5% for every field size and wedge angle. The SDs of the distribution were within the estimated uncertainty, except for one condition that was not reliable because of poor statistics.« less
Seismic evidence for a cold serpentinized mantle wedge beneath Mount St Helens
Hansen, S. M.; Schmandt, B.; Levander, A.; Kiser, E.; Vidale, J. E.; Abers, G. A.; Creager, K. C.
2016-01-01
Mount St Helens is the most active volcano within the Cascade arc; however, its location is unusual because it lies 50 km west of the main axis of arc volcanism. Subduction zone thermal models indicate that the down-going slab is decoupled from the overriding mantle wedge beneath the forearc, resulting in a cold mantle wedge that is unlikely to generate melt. Consequently, the forearc location of Mount St Helens raises questions regarding the extent of the cold mantle wedge and the source region of melts that are responsible for volcanism. Here using, high-resolution active-source seismic data, we show that Mount St Helens sits atop a sharp lateral boundary in Moho reflectivity. Weak-to-absent PmP reflections to the west are attributed to serpentinite in the mantle-wedge, which requires a cold hydrated mantle wedge beneath Mount St Helens (<∼700 °C). These results suggest that the melt source region lies east towards Mount Adams. PMID:27802263
Conical refraction of elastic waves in absorbing crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alshits, V. I., E-mail: alshits@ns.crys.ras.ru; Lyubimov, V. N.
2011-10-15
The absorption-induced acoustic-axis splitting in a viscoelastic crystal with an arbitrary anisotropy is considered. It is shown that after 'switching on' absorption, the linear vector polarization field in the vicinity of the initial degeneracy point having an orientation singularity with the Poincare index n = {+-}1/2, transforms to a planar distribution of ellipses with two singularities n = {+-}1/4 corresponding to new axes. The local geometry of the slowness surface of elastic waves is studied in the vicinity of new degeneracy points and a self-intersection line connecting them. The absorption-induced transformation of the classical picture of conical refraction is studied.more » The ellipticity of waves at the edge of the self-intersection wedge in a narrow interval of propagation directions drastically changes from circular at the wedge ends to linear in the middle of the wedge. For the wave normal directed to an arbitrary point of this wedge, during movement of the displacement vector over the corresponding polarization ellipse, the wave ray velocity s runs over the same cone describing refraction in a crystal without absorption. In this case, the end of the vector moves along a universal ellipse whose plane is orthogonal to the acoustic axis for zero absorption. The areal velocity of this movement differs from the angular velocity of the displacement vector on the polarization ellipse only by a constant factor, being delayed by {pi}/2 in phase. When the wave normal is localized at the edge of the wedge in its central region, the movement of vector s along the universal ellipse becomes drastically nonuniform and the refraction transforms from conical to wedge-like.« less
Kim, D Y; Ahn, Y C; Oh, D G; Choi, D R; Ju, S G; Yeo, I H; Huh, S J
2000-09-01
A new collimator cone system has been developed at the Samsung Medical Center that overcomes some of the limitations of present commercially supplied collimator cones. The physical properties of the newly developed cone system are described in this report. The new cones have relatively larger aperture sizes (3.0-7.0 cm in diameter) and are 16 cm in length. Each new cone is fabricated with cerrobend alloy melted and poured into a stainless steel housing that is permanently fixed to a mounting plate. The mounting plate of the new cone is designed to insert into the wedge mount slot of the gantry head. The mechanical accuracy of the central axis of the cone pointing to the isocenter was tested using film, a steel ball positioned at the isocenter by the mechanical isocenter device. For the evaluation of beam flatness and penumbra, off-axis ratios at 5 cm depth were measured by film dosimetry using polystyrene phantom. The average error of the mechanical isocenter was 0.27 mm (+/- 0.16 mm). The beam flatness was excellent in the central region of the beam, and the average penumbra width was 3.35 mm (+/- 0.25 mm). The new cone design has more clearance between the patient's head and the gantry, and can more easily be removed from the gantry head because it slides in and out of the wedge slot. This facilitates changing cone sizes during one treatment session, and makes the process of double exposure port films easier. A new collimator cone system for stereotactic radiation therapy has been developed. The mechanical accuracy and physical properties are satisfactory for clinical use, and the new design permits a wider range of clinical applications for stereotactic radiation therapy.
NASA Technical Reports Server (NTRS)
Carson, George T., Jr.; Bare, E. Ann; Burley, James R., II
1987-01-01
An investigation was conducted in the Langley 16-Foot Transonic Tunnel to determine the effect of a boattail angle and wedge-size trade on the performance of nonaxisymmetric wedge nozzles installed on a generic twin-engine fighter aircraft model. Test data were obtained at static conditions and at Mach numbers from 0.60 to 1.25. Angle of attack was held constant at 0 deg. High-pressure air was used to simulate jet exhaust, and the nozzle pressure ratio was varied from 1.0 (jet off) to slightly over 15.0. For the configurations studied, the results indicate that wedge size can be reduced without affecting aeropropulsive performance.
Filopodial adhesion does not predict growth cone steering events in vivo.
Isbister, C M; O'Connor, T P
1999-04-01
Migration of growth cones is in part mediated by adhesive interactions between filopodia and the extracellular environment, transmitting forces and signals necessary for pathfinding. To elucidate the role of substrate adhesivity in growth cone pathfinding, we developed an in vivo assay for measuring filopodial-substrate adhesivity using the well-characterized Ti pioneer neuron pathway of the embryonic grasshopper limb. Using time-lapse imaging and a combination of rhodamine-phalloidin injections and DiI labeling, we demonstrate that the filopodial retraction rate after treatment with cytochalasin D or elastase reflects the degree of filopodial-substrate adhesivity. Measurements of filopodial retraction rates along regions of known differing substrate adhesivities confirmed the use of this assay to examine filopodial-substrate adhesion during in vivo pathfinding events. We analyzed 359 filopodia from 22 Ti growth cones and found that there is no difference between the retraction rates of filopodia extending toward the correct target (on-axis) and filopodia extending away from the correct target (off-axis). These results indicate on-axis and off-axis filopodia have similar substrate adherence. Interestingly, we observed a 300% increase in the extension rates of on-axis filopodia during Ti growth cone turning events. Therefore, in addition to providing filopodia with important guidance information, regional cues are capable of modulating the filopodial extension rate. The homogeneity in filopodial retraction rates, even among these turning growth cones in which differential adhesivity might be expected to be greatest, strongly establishes that differential adhesion does not govern Ti pioneer neuron migration rate or pathfinding. We propose that the presence of local differences in receptor-mediated second messenger cascades and the resulting assembly of force-generating machinery may underlie the ability of filopodial contacts to regulate growth cone steering in vivo.
NASA Astrophysics Data System (ADS)
Brian Leen, J.; Berman, Elena S. F.; Liebson, Lindsay; Gupta, Manish
2012-04-01
Developments in cavity-enhanced absorption spectrometry have made it possible to measure water isotopes using faster, more cost-effective field-deployable instrumentation. Several groups have attempted to extend this technology to measure water extracted from plants and found that other extracted organics absorb light at frequencies similar to that absorbed by the water isotopomers, leading to δ2H and δ18O measurement errors (Δδ2H and Δδ18O). In this note, the off-axis integrated cavity output spectroscopy (ICOS) spectra of stable isotopes in liquid water is analyzed to determine the presence of interfering absorbers that lead to erroneous isotope measurements. The baseline offset of the spectra is used to calculate a broadband spectral metric, mBB, and the mean subtracted fit residuals in two regions of interest are used to determine a narrowband metric, mNB. These metrics are used to correct for Δδ2H and Δδ18O. The method was tested on 14 instruments and Δδ18O was found to scale linearly with contaminant concentration for both narrowband (e.g., methanol) and broadband (e.g., ethanol) absorbers, while Δδ2H scaled linearly with narrowband and as a polynomial with broadband absorbers. Additionally, the isotope errors scaled logarithmically with mNB. Using the isotope error versus mNB and mBB curves, Δδ2H and Δδ18O resulting from methanol contamination were corrected to a maximum mean absolute error of 0.93 ‰ and 0.25 ‰ respectively, while Δδ2H and Δδ18O from ethanol contamination were corrected to a maximum mean absolute error of 1.22 ‰ and 0.22 ‰. Large variation between instruments indicates that the sensitivities must be calibrated for each individual isotope analyzer. These results suggest that the properly calibrated interference metrics can be used to correct for polluted samples and extend off-axis ICOS measurements of liquid water to include plant waters, soil extracts, wastewater, and alcoholic beverages. The general technique may also be extended to other laser-based analyzers including methane and carbon dioxide isotope sensors.
Bae, Dae Kyung; Lee, Jong Whan; Cho, Seong Jin; Song, Sang Jun
2017-01-01
Purpose To compare navigation and weight bearing radiographic measurements of mechanical axis (MA) before and after closed wedge high tibial osteotomy (HTO) and to evaluate post-osteotomy changes in MA assessed during application of external varus or valgus force. Materials and Methods Data from 30 consecutive patients (30 knees) who underwent computer-assisted closed-wedge HTO were prospectively analyzed. Pre- and postoperative weight bearing radiographic evaluation of MA was performed. Under navigation guidance, pre- and post-osteotomy MA values were measured in an unloaded position. Any change in the post-osteotomy MA in response to external varus or valgus force, which was named as dynamic range, was evaluated with the navigation system. The navigation and weight bearing radiographic measurements were compared. Results Although there was a positive correlation between navigation and radiographic measurements, the reliability of navigation measurements of coronal alignment was reduced after osteotomy and wedge closing. The mean post-osteotomy MA value measured with the navigation was 3.5°±0.8° valgus in an unloaded position. It was 1.3°±0.8° valgus under varus force and 5.8°±1.1° valgus under valgus force. The average dynamic range was >±2°. Conclusions Potential differences between the postoperative MAs assessed by weight bearing radiographs and the navigation system in unloaded position should be considered during computer-assisted closed wedge HTO. Care should be taken to keep the dynamic range within the permissible range of alignment goal in HTO. PMID:28854769
NASA Astrophysics Data System (ADS)
Saiki, A.; Hashimoto, Y.
2015-12-01
Evolution of physical properties in subduction zone is a key to understand lithification processes, location of decollement, and stress distribution. In this study, we examined the physical properties of sediments using on-board data and laboratory experimental data on sediments obtained off Costa Rica margin. Target sites are in the Integrate Ocean Drilling Program (IODP) Expedition 344 off Costa Rica, including reference sites (U1381 and U1414), mid-slope site (U1378, U1380) and upper-slope site (U1413). Seven samples from reference sites were analyzed. Laboratory experiments for velocity and porosity measurements were conducted with variation of effective pressure. Velocity-porosity relationships from on-board data and from laboratory experiments are comparable. The porosity-effective pressure curves under isotropic condition were converted to the curves under uniaxial condition (Teeuw, 1971). Using the normal consolidation curves under uniaxial stress conditions, we converted onboard porosity to effective pressure and fluid pressure. In reference sites, hydrostatic fluid pressure was estimated as expected as a reference sites, suggesting that porosity-effective pressure relationship was obtained correctly by experiments and it can be adapted to estimation of fluid pressure for the wedge sites. The porosity-effective pressure relationship under isotropic conditions were used for the estimation in wedge sites. In wedge sites, estimated pore pressures show lower than hydrostatic pressure, suggesting that onboard porosity was lower than that under normal compaction. The lower porosity can be caused by relative uplift from deeper portion. The amount of relative uplift can be estimated by differences in porosity-depth relationships between onboard data and experimental data. The amount of relative uplift for each site shows more than ~1000m up to ~5000m. The small error in porosity depth curve from experimental data makes relative uplift larger or smaller exponentially in the deeper portion. The increment of relative uplift, however, starts from about 1Ma in each site, suggesting some events were occurred at the timing. Laboratory experiments under differential stress should be conducted in the near future because smaller porosity is expected under differential stress conditions.
2008-06-01
didn’t stop, the grappling hooks were re- motely engaged to latch onto the vehicle while the airbags deployed to lift the vehicle off the ground...successfully stopping it. The other device was a simple wooden wedge . If you didn’t stop, your vehicle would run up onto the in- cline of the wedge and
Seismic reflection images of the accretionary wedge of Costa Rica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shipley, T.H.; Stoffa, P.L.; McIntosh, K.
The large-scale structure of modern accretionary wedges is known almost entirely from seismic reflection investigations using single or grids of two-dimensional profiles. The authors will report on the first three-dimensional seismic reflection data volume collected of a wedge. This data set covers a 9-km-wide {times} 22-km-long {times} 6-km-thick volume of the accretionary wedge just arcward of the Middle America Trench off Costa Rica. The three-dimensional processing has improved the imaging ability of the multichannel data, and the data volume allows mapping of structures from a few hundred meters to kilometers in size. These data illustrate the relationships between the basement,more » the wedge shape, and overlying slope sedimentary deposits. Reflections from within the wedge define the gross structural features and tectonic processes active along this particular convergent margin. So far, the analysis shows that the subdued basement relief (horst and graben structures seldom have relief of more than a few hundred meters off Costa Rica) does affect the larger scale through going structural features within the wedge. The distribution of mud volcanoes and amplitude anomalies associated with the large-scale wedge structures suggests that efficient fluid migration paths may extend from the top of the downgoing slab at the shelf edge out into the lower and middle slope region at a distance of 50-100 km. Offscraping of the uppermost (about 45 m) sediment occurs within 4 km of the trench, creating a small pile of sediments near the trench lower slope. Underplating of parts of the 400-m-thick subducted sedimentary section begins at a very shallow structural level, 4-10 km arcward of the trench. Volumetrically, the most important accretionary process is underplating.« less
NASA Astrophysics Data System (ADS)
Mazoyer, J.; Pueyo, L.; N'Diaye, M.; Fogarty, K.; Zimmerman, N.; Leboulleux, L.; St. Laurent, K. E.; Soummer, R.; Shaklan, S.; Norman, C.
2018-01-01
Future searches for bio-markers on habitable exoplanets will rely on telescope instruments that achieve extremely high contrast at small planet-to-star angular separations. Coronagraphy is a promising starlight suppression technique, providing excellent contrast and throughput for off-axis sources on clear apertures. However, the complexity of space- and ground-based telescope apertures goes on increasing over time, owing to the combination of primary mirror segmentation, the secondary mirror, and its support structures. These discontinuities in the telescope aperture limit the coronagraph performance. In this paper, we present ACAD-OSM, a novel active method to correct for the diffractive effects of aperture discontinuities in the final image plane of a coronagraph. Active methods use one or several deformable mirrors that are controlled with an interaction matrix to correct for the aberrations in the pupil. However, they are often limited by the amount of aberrations introduced by aperture discontinuities. This algorithm relies on the recalibration of the interaction matrix during the correction process to overcome this limitation. We first describe the ACAD-OSM technique and compare it to the previous active methods for the correction of aperture discontinuities. We then show its performance in terms of contrast and off-axis throughput for static aperture discontinuities (segmentation, struts) and for some aberrations evolving over the life of the instrument (residual phase aberrations, artifacts in the aperture, misalignments in the coronagraph design). This technique can now obtain the Earth-like planet detection threshold of {10}10 contrast on any given aperture over at least a 10% spectral bandwidth, with several coronagraph designs.
Zhu, X. R.
2000-01-01
Silicon diode dosimeters have been used routinely for in‐vivo dosimetry. Despite their popularity, an appropriate implementation of an in‐vivo dosimetry program using diode detectors remains a challenge for clinical physicists. One common approach is to relate the diode readout to the entrance dose, that is, dose to the reference depth of maximum dose such as dmax for the 10×10 cm2 field. Various correction factors are needed in order to properly infer the entrance dose from the diode readout, depending on field sizes, target‐to‐surface distances (TSD), and accessories (such as wedges and compensate filters). In some clinical practices, however, no correction factor is used. In this case, a diode‐dosimeter‐based in‐vivo dosimetry program may not serve the purpose effectively; that is, to provide an overall check of the dosimetry procedure. In this paper, we provide a formula to relate the diode readout to the entrance dose. Correction factors for TSD, field size, and wedges used in this formula are also clearly defined. Two types of commercial diode detectors, ISORAD (n‐type) and the newly available QED (p‐type) (Sun Nuclear Corporation), are studied. We compared correction factors for TSDs, field sizes, and wedges. Our results are consistent with the theory of radiation damage of silicon diodes. Radiation damage has been shown to be more serious for n‐type than for p‐type detectors. In general, both types of diode dosimeters require correction factors depending on beam energy, TSD, field size, and wedge. The magnitudes of corrections for QED (p‐type) diodes are smaller than ISORAD detectors. PACS number(s): 87.66.–a, 87.52.–g PMID:11674824
Radiographic Outcomes Following Lateral Column Lengthening With a Porous Titanium Wedge.
Gross, Christopher E; Huh, Jeannie; Gray, Joni; Demetracopoulos, Constantine; Nunley, James A
2015-08-01
Lateral column lengthening (LCL) is commonly utilized in treating stage II posterior tibialis tendon dysfunction. This study aimed to analyze the outcomes of LCL with porous titanium wedges compared to historic controls of iliac crest autograft and allograft. We hypothesized that the use of a porous titanium wedge would have radiographic improvement and union rates similar to those with the use of autograft and allograft in LCL. Between May 2009 and May 2014, 28 feet in 26 patients were treated with LCL using a porous titanium wedge. Of the 26 patients, 9 were males (34.6%). The average age for males was 43 years (range, 17.9-58.7), 48.7 years (range, 21-72.3) for females. Mean follow-up was 14.6 months. Radiographs were examined for correction of the flatfoot deformity and forefoot abduction. All complications were noted. Radiographically, the patients had a significant deformity correction in the anteroposterior talo-first metatarsal angle, talonavicular coverage angle, lateral talo-first metatarsal angle, and calcaneal pitch. All but 1 patient (96%) had bony incorporation of the porous titanium wedge. The average preoperative visual analog scale pain score was 5; all patients but 3 (12%) had improvements in their pain score, with a mean change of 3.4. LCL with porous titanium had low nonunion rates, improved radiographic correction, and pain relief. Level IV, case series. © The Author(s) 2015.
Polarization sensitive localization based super-resolution microscopy with a birefringent wedge
NASA Astrophysics Data System (ADS)
Sinkó, József; Gajdos, Tamás; Czvik, Elvira; Szabó, Gábor; Erdélyi, Miklós
2017-03-01
A practical method has been presented for polarization sensitive localization based super-resolution microscopy using a birefringent dual wedge. The measurement of the polarization degree at the single molecule level can reveal the chemical and physical properties of the local environment of the fluorescent dye molecule and can hence provide information about the sub-diffraction sized structure of biological samples. Polarization sensitive STORM imaging of the F-Actins proved correlation between the orientation of fluorescent dipoles and the axis of the fibril.
Chevron closing base wedge bunionectomy.
Bruyn, J M
1993-01-01
The Chevron-base wedge Association for Osteosynthesis fixated bunionectomy provides a stable, aggressive correction of the severe hallux abducto valgus deformity. It is intended for the bunion requiring a double osteotomy in order to adequately reduce both intermetatarsal and proximal articular facet angle with minimal shortening and elevation. This article presents the rationale for the procedure, technique, and a 4-year follow-up of six patients with eight Chevron-base wedge bunionectomies.
Price, Jeffery R.; Bingham, Philip R.
2005-11-08
Systems and methods are described for rapid acquisition of fused off-axis illumination direct-to-digital holography. A method of recording a plurality of off-axis object illuminated spatially heterodyne holograms, each of the off-axis object illuminated spatially heterodyne holograms including spatially heterodyne fringes for Fourier analysis, includes digitally recording, with a first illumination source of an interferometer, a first off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording, with a second illumination source of the interferometer, a second off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
Fracture modes in off-axis fiber composites
NASA Technical Reports Server (NTRS)
Sinclair, J. H.; Chamis, C. C.
1978-01-01
Criteria were developed for identifying, characterizing, and quantifying fracture modes in high-modulus graphite-fiber/resin unidirectional composites subjected to off-axis tensile loading. Procedures are described which use sensitivity analyses and off-axis data to determine the uniaxial strength of fiber composites. It was found that off-axis composites fail by three fracture modes which produce unique fracture surface characteristics. The stress that dominates each fracture mode and the load angle range of its dominance can be identified. Linear composite mechanics is adequate to describe quantitatively the mechanical behavior of off-axis composites. The uniaxial strengths predicted from off-axis data are comparable to these measured in uniaxial tests.
Cho, Nakwon
1980-01-01
A positive acting valve suitable for operation in a corrosive environment is provided. The valve includes a hollow valve body defining an open-ended bore for receiving two, axially aligned, spaced-apart, cylindrical inserts. One insert, designated the seat insert, terminates inside the valve body in an annular face which lies within plane normal to the axis of the two inserts. An elastomeric O-ring seal is disposed in a groove extending about the annular face. The other insert, designated the wedge insert, terminates inside the valve body in at least two surfaces oppositely inclined with respect to each other and with respect to a plane normal to the axis of the two inserts. An elongated reciprocable gate, movable between the two inserts along a path normal to the axis of the two inserts, has a first flat face portion disposed adjacent and parallel to the annular face of the seat insert. The gate has a second face portion opposite to the first face portion provided with at least two oppositely inclined surfaces for mating with respective inclined surfaces of the wedge insert. An opening is provided through the gate which registers with a flow passage through the two inserts when the valve is open. Interaction of the respective inclined surfaces of the gate and wedge insert act to force the first flat face portion of the gate against the O-ring seal in the seat insert at the limits of gate displacement where it reaches its respective fully open and fully closed positions.
Cost analysis of a mini-facet heliostat
NASA Astrophysics Data System (ADS)
Hall, Colin; Pratt, Rodney; Farrant, David; Corsi, Clotilde; Pye, John; Coventry, Joe
2017-06-01
A significant problem with conventional heliostats is off-axis astigmatism, which increases the spot size at the central receiver, limiting the temperature and efficiency of solar thermal systems. Inspired by low-cost mini-actuators used for car wing mirrors, we examine the economic feasibility of a heliostat with individually adjustable mini-facets to correct astigmatic effects, and we compare three alternative tracking configurations.
NASA Astrophysics Data System (ADS)
Wang, Xuan-Yin; Du, Jia-Wei; Zhu, Shi-Qiang
2017-09-01
A bionic variable-focus lens with symmetrical layered structure was designed to mimic the crystalline lens. An optical imaging system based on this lens and with a symmetrical structure that mimics the human eye structure was proposed. The refractive index of the bionic variable-focus lens increases from outside to inside. The two PDMS lenses with a certain thickness were designed to improve the optical performance of the optical imaging system and minimise the gravity effect of liquid. The paper presents the overall structure of the optical imaging system and the detailed description of the bionic variable-focus lens. By pumping liquid in or out of the cavity, the surface curvatures of the rear PDMS lens were varied, resulting in a change in the focal length. The focal length range of the optical imaging system was 20.71-24.87 mm. The optical performance of the optical imaging system was evaluated by imaging experiments and analysed by ray tracing simulations. On the basis of test and simulation results, the optical performance of the system was quite satisfactory. Off-axis aberrations were well corrected, and the image quality was greatly improved.
[Closing wedge osteotomy of the tibial head in treatment of single compartment arthrosis].
Jakob, R P; Jacobi, M
2004-02-01
Closing wedge high tibial osteotomy is an efficient method for the treatment of medial osteoarthritis of the knee. Prerequisites of successful surgery are proper indication and planning as well as the understanding of biomechanics and pathophysiology. The technique of osteotomy to choose (opening or closing wedge) depends on the type of malalignment and on additional pathologies. The surgical technique demands high precision to realize the planned correction and to avoid complications. Implants with angular stability provide advantages compared to traditional implants. Correct indication and surgical technique results in a desirable follow-up, which often lasts for at least 10 years. The effect on the prognosis of the young patient with cartilage damage is still unclear.
Off-axis illumination direct-to-digital holography
Thomas, Clarence E.; Price, Jeffery R.; Voelkl, Edgar; Hanson, Gregory R.
2004-06-08
Systems and methods are described for off-axis illumination direct-to-digital holography. A method of recording an off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis, includes: reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object at an angle with respect to an optical axis defined by a focusing lens; focusing the reference beam and the object beam at a focal plane of a digital recorder to form the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digitally recording the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; Fourier analyzing the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes by transforming axes of the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined as an angle between the reference beam and the object beam; applying a digital filter to cut off signals around an original origin; and then performing an inverse Fourier transform.
Model-based estimation and control for off-axis parabolic mirror alignment
NASA Astrophysics Data System (ADS)
Fang, Joyce; Savransky, Dmitry
2018-02-01
This paper propose an model-based estimation and control method for an off-axis parabolic mirror (OAP) alignment. Current studies in automated optical alignment systems typically require additional wavefront sensors. We propose a self-aligning method using only focal plane images captured by the existing camera. Image processing methods and Karhunen-Loève (K-L) decomposition are used to extract measurements for the observer in closed-loop control system. Our system has linear dynamic in state transition, and a nonlinear mapping from the state to the measurement. An iterative extended Kalman filter (IEKF) is shown to accurately predict the unknown states, and nonlinear observability is discussed. Linear-quadratic regulator (LQR) is applied to correct the misalignments. The method is validated experimentally on the optical bench with a commercial OAP. We conduct 100 tests in the experiment to demonstrate the consistency in between runs.
Full range line-field parallel swept source imaging utilizing digital refocusing
NASA Astrophysics Data System (ADS)
Fechtig, Daniel J.; Kumar, Abhishek; Drexler, Wolfgang; Leitgeb, Rainer A.
2015-12-01
We present geometric optics-based refocusing applied to a novel off-axis line-field parallel swept source imaging (LPSI) system. LPSI is an imaging modality based on line-field swept source optical coherence tomography, which permits 3-D imaging at acquisition speeds of up to 1 MHz. The digital refocusing algorithm applies a defocus-correcting phase term to the Fourier representation of complex-valued interferometric image data, which is based on the geometrical optics information of the LPSI system. We introduce the off-axis LPSI system configuration, the digital refocusing algorithm and demonstrate the effectiveness of our method for refocusing volumetric images of technical and biological samples. An increase of effective in-focus depth range from 255 μm to 4.7 mm is achieved. The recovery of the full in-focus depth range might be especially valuable for future high-speed and high-resolution diagnostic applications of LPSI in ophthalmology.
Characteristics of phase-correcting fresnel zone plates and elliptical waveguides
NASA Astrophysics Data System (ADS)
Wiltse, James C.
1994-02-01
The primary area of activity has been concentrated on the investigations relating to Fresnel zone plate antennas. A secondary effort has dealt with the characteristics of propagation in waveguides of elliptical cross section. In both cases, applications at microwave and millimeter-wavelengths have been emphasized. Thorough literature searches were conducted, and the results are given in Appendices A and B. The zone plate work has dealt with both transmission and reflection types, and has included considering the off-axis-fed cases. In the latter case, the plate may consist of elliptical zones, rather than the usual circular configuration. In general, the characteristics studied include far-field patterns, focal region fields, off-axis performance, bandwidth, and aberrations. In the case of propagation in elliptical waveguides, the attenuation and modal properties were studied for enclosed metal waveguides, coaxial transmission lines, and various surface waveguides.
Aspheric figure generation using feedback from an infrared phase-shifting interferometer
NASA Astrophysics Data System (ADS)
Stahl, H. P.; Ketelsen, D.
An infrared phase-shifting interferometric system has been integrated with a novel optical figure generator at the University of Arizona Optical Sciences Center. This unique generator facility can produce generalized axially symmetric surface figures in a timely and cost-effective manner. The success of this facility depends on both its ability to efficiently remove material while forming the surface figure, and its ability to monitor the surface figure during the generation process to provide feedback to the optician. The facility has been used on several occasions to custom-generate off-axis parabolic segments. Figures to within 0.30 microns rms of the desired figure have been obtained. This paper discusses the usefulness of the infrared phase-shifting interferometric system for providing figure correcting feedback to the optician during the generation of the off-axis parabolic segments, and how it is affected by the surface roughness produced by each generator tool.
NASA Astrophysics Data System (ADS)
Cox, G. M.; Mccue, S. W.; Thamwattana, N.; Hill, J. M.
Under certain circumstances, an industrial hopper which operates under the "funnel-flow" regime can be converted to the "mass-flow" regime with the addition of a flow-corrective insert. This paper is concerned with calculating granular flow patterns near the outlet of hoppers that incorporate a particular type of insert, the cone-in-cone insert. The flow is considered to be quasi-static, and governed by the Coulomb-Mohr yield condition together with the non-dilatant double-shearing theory. In two-dimensions, the hoppers are wedge-shaped, and as such the formulation for the wedge-in-wedge hopper also includes the case of asymmetrical hoppers. A perturbation approach, valid for high angles of internal friction, is used for both two-dimensional and axially symmetric flows, with analytic results possible for both leading order and correction terms. This perturbation scheme is compared with numerical solutions to the governing equations, and is shown to work very well for angles of internal friction in excess of 45°.
Borg, L.E.; Clynne, M.A.; Bullen, T.D.
1997-01-01
The compositional continuum observed in primitive calc-alkaline lavas erupted from small volcanoes across the southernmost Cascade arc is produced by the introduction of a variable proportion of slab-derived fluid into the superjacent peridotite layer of the mantle wedge. Magmas derived from fluid-rich sources are erupted primarily in the forearc and are characterized by Sr and Pb enrichment (primitive mantle-normalized Sr/P > 5.5), depletions of Ta and Nb, low incompatible-element abundances, and MORB-like Sr and Pb isotopic ratios. Magmas derived from fluid-poor sources are erupted primarily in the arc axis and behind the arc, and are characterized by weak enrichment in Sr [1.0 < (Sr/P)N < 1.3], weak depletions in Ta and Nb, higher incompatible-element abundances, and OIB-like Sr, Nd, and Pb isotopic ratios. Fluxing the mantle wedge above the subducting slab with H2O-rich fluid stabilizes amphibole and enriches the wedge peridotites in incompatible elements, particularly unradiogenic Sr and Pb. The hydrated amphibole-bearing portion of the mantle wedge is downdragged beneath the forearc, where its solidus is exceeded, yielding melts that are enriched in Sr and Pb, and depleted in Ta and Nb (reflecting both high Sr and Pb relative to Ta and Nb in the fluid, and the greater compatibility of Ta and Nb in amphibole compared to other silicate phases in the wedge). A steady decrease of the fluid-contributed geochemical signature away from the trench is produced by the progressive dehydration of the downdragged portion of the mantle wedge with depth, resulting from melt extraction and increased temperature at the slab-wedge interface. Inverse correlation between incompatible-element abundances and the size of the fluid-contributed geochemical signature is generated by melting of more depleted peridotites, rather than by significant differences in the degree of melting. High-(Sr/P)N lavas of the forearc are generated by melting of a MORB-source-like peridotite that has been fluxed with a greater proportion of slab-derived fluid, and low (Sr/P)N lavas of the arc axis are produced by melting of an OIB-source-like peridotite in the presence of a smaller proportion of slab-derived fluid. This study documents the control that a slab-derived fluid can have on incompatible element and isotopic systematics of arc magmas by 1) the addition of incompatible elements to the wedge, 2) the stabilization of hydrous phases in the wedge, and 3) the lowering of peridotite solidi.
NASA Technical Reports Server (NTRS)
Ohl, Raymond G.; Mink, Ronald; Chambers, V. John; Connelly, Joseph A.; Mentzell, J. Eric; Tveekrem, June L.; Howard, Joseph M.; Preuss, Werner; Schroeder, Mechthild; Sohn, Alex;
2002-01-01
Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brian Leen, J.; Berman, Elena S. F.; Gupta, Manish
Developments in cavity-enhanced absorption spectrometry have made it possible to measure water isotopes using faster, more cost-effective field-deployable instrumentation. Several groups have attempted to extend this technology to measure water extracted from plants and found that other extracted organics absorb light at frequencies similar to that absorbed by the water isotopomers, leading to {delta}{sup 2}H and {delta}{sup 18}O measurement errors ({Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O). In this note, the off-axis integrated cavity output spectroscopy (ICOS) spectra of stable isotopes in liquid water is analyzed to determine the presence of interfering absorbers that lead to erroneous isotope measurements. The baseline offsetmore » of the spectra is used to calculate a broadband spectral metric, m{sub BB}, and the mean subtracted fit residuals in two regions of interest are used to determine a narrowband metric, m{sub NB}. These metrics are used to correct for {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O. The method was tested on 14 instruments and {Delta}{delta}{sup 18}O was found to scale linearly with contaminant concentration for both narrowband (e.g., methanol) and broadband (e.g., ethanol) absorbers, while {Delta}{delta}{sup 2}H scaled linearly with narrowband and as a polynomial with broadband absorbers. Additionally, the isotope errors scaled logarithmically with m{sub NB}. Using the isotope error versus m{sub NB} and m{sub BB} curves, {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O resulting from methanol contamination were corrected to a maximum mean absolute error of 0.93 per mille and 0.25 per mille respectively, while {Delta}{delta}{sup 2}H and {Delta}{delta}{sup 18}O from ethanol contamination were corrected to a maximum mean absolute error of 1.22 per mille and 0.22 per mille . Large variation between instruments indicates that the sensitivities must be calibrated for each individual isotope analyzer. These results suggest that the properly calibrated interference metrics can be used to correct for polluted samples and extend off-axis ICOS measurements of liquid water to include plant waters, soil extracts, wastewater, and alcoholic beverages. The general technique may also be extended to other laser-based analyzers including methane and carbon dioxide isotope sensors.« less
NASA Astrophysics Data System (ADS)
Thornton, Douglas E.; Spencer, Mark F.; Perram, Glen P.
2017-09-01
The effects of deep turbulence in long-range imaging applications presents unique challenges to properly measure and correct for aberrations incurred along the atmospheric path. In practice, digital holography can detect the path-integrated wavefront distortions caused by deep turbulence, and di erent recording geometries offer different benefits depending on the application of interest. Previous studies have evaluated the performance of the off-axis image and pupil plane recording geometries for deep-turbulence sensing. This study models digital holography in the on-axis phase shifting recording geometry using wave optics simulations. In particular, the analysis models spherical-wave propagation through varying deep-turbulence conditions to estimate the complex optical field, and performance is evaluated by calculating the field-estimated Strehl ratio and RMS wavefront error. Altogether, the results show that digital holography in the on-axis phase shifting recording geometry is an effective wavefront-sensing method in the presence of deep turbulence.
Off-axis points encoding/decoding with orbital angular momentum spectrum
Chu, Jiaqi; Chu, Daping; Smithwitck, Quinn
2017-01-01
Encoding/decoding off-axis points with discrete orbital angular momentum (OAM) modes is investigated. On-axis Laguerre-Gaussian (LG) beams are expanded into off-axis OAM spectra, with which off-axis points are encoded. The influence of the mode and the displacement of the LG beam on the spread of the OAM spectrum is analysed. The results show that not only the conventional on-axis point, but also off-axis points, can be encoded and decoded with OAM of light. This is confirmed experimentally. The analytical result here provides a solid foundation to use OAM modes to encode two-dimensional high density information for multiplexing and to analyse the effect of mis-alignment in practical OAM applications. PMID:28272543
GIFTS SM EDU Data Processing and Algorithms
NASA Technical Reports Server (NTRS)
Tian, Jialin; Johnson, David G.; Reisse, Robert A.; Gazarik, Michael J.
2007-01-01
The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration stage. The calibration procedures can be subdivided into three stages. In the pre-calibration stage, a phase correction algorithm is applied to the decimated and filtered complex interferogram. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected blackbody reference spectra. In the radiometric calibration stage, we first compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. During the post-processing stage, we estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. We then implement a correction scheme that compensates for the effect of fore-optics offsets. Finally, for off-axis pixels, the FPA off-axis effects correction is performed. To estimate the performance of the entire FPA, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation.
Proposal 11913-IR Filter Wedge Check
NASA Astrophysics Data System (ADS)
Sabbi, E.; MacKenty, J.; Borders, T.
2010-08-01
Variations in the thickness of a filter alter the path of the incoming light beam, causing an apparent displacement of the observed sources. Proposal 11913 was designed to verify the coplanarity of the WFC3/ IR filters, i.e. whether any of them was wedged, and if so, to evaluate the impact on the astrometry. We found that, with the exception of the F098M and F126N filters, the positions of stars observed through different filters, without moving the telescope, differ on average by less then 0.14 ±0.06 pixels and match the CEI specifications. In addition we found that the positional shifts increase along the X-axis and decrease along the Y-axis as a function of wavelength. The observed shifts are consistent with the fact that the refractive corrector plate (RCP) is tilted ~8.6 degree to the center of the field center chief ray.
A Comparison of Off-Level Correction Techniques for Airborne Gravity using GRAV-D Re-Flights
NASA Astrophysics Data System (ADS)
Preaux, S. A.; Melachroinos, S.; Diehl, T. M.
2011-12-01
The airborne gravity data collected for the GRAV-D project contain a number of tracks which have been flown multiple times, either by design or due to data collection issues. Where viable data can be retrieved, these re-flights are a valuable resource not only for assessing the quality of the data but also for evaluating the relative effectiveness of various processing techniques. Correcting for the instantaneous misalignment of the gravimeter sensitive axis with local vertical has been a long standing challenge for stable platform airborne gravimetry. GRAV-D re-flights are used to compare the effectiveness of existing methods of computing this off-level correction (Valliant 1991, Peters and Brozena 1995, Swain 1996, etc.) and to assess the impact of possible modifications to these methods including pre-filtering accelerations, use of IMU horizontal accelerations in place of those derived from GPS positions and accurately compensating for GPS lever-arm and attitude effects prior to computing accelerations from the GPS positions (Melachroinos et al. 2010, B. de Saint-Jean, et al. 2005). The resulting corrected gravity profiles are compared to each other and to EGM08 in order to assess the accuracy and precision of each method. Preliminary results indicate that the methods presented in Peters & Brozena 1995 and Valliant 1991 completely correct the off-level error some of the time but only partially correct it others, while introducing an overall bias to the data of -0.5 to -2 mGal.
Design of Off-Axis PIAACMC Mirrors
NASA Technical Reports Server (NTRS)
Pluzhnik, Eugene; Guyon, Olivier; Belikov, Ruslan; Kern, Brian; Bendek, Eduardo
2015-01-01
The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) provides an efficient way to control diffraction propagation effects caused by the central obstruction/segmented mirrors of the telescope. PIAACMC can be optimized in a way that takes into account both chromatic diffraction effects caused by the telescope obstructed aperture and tip/tilt sensitivity of the coronagraph. As a result, unlike classic PIAA, the PIAACMC mirror shapes are often slightly asymmetric even for an on-axis configuration and require more care in calculating off-axis shapes when an off-axis configuration is preferred. A method to design off-axis PIAA mirror shapes given an on-axis mirror design is presented. The algorithm is based on geometrical ray tracing and is able to calculate off-axis PIAA mirror shapes for an arbitrary geometry of the input and output beams. The method is demonstrated using the third generation PIAACMC design for WFIRST-AFTA (Wide Field Infrared Survey Telescope-Astrophysics Focused Telescope Assets) telescope. Geometrical optics design issues related to the off-axis diffraction propagation effects are also discussed.
Cameron, James I; McCauley, Julie C; Kermanshahi, Arash Y; Bugbee, William D
2015-06-01
Distal femoral varus osteotomy may be used to treat valgus knee malalignment or to protect a knee compartment in which cartilage restoration surgery (such as osteochondral or meniscus allografting) has been performed. Medial closing-wedge osteotomy has demonstrated good success in treatment of osteoarthritis in published series, but few studies have evaluated distal femoral lateral opening-wedge osteotomy in terms of correction of deformity, pain and function, and survivorship. (1) Does lateral opening-wedge osteotomy lead to accurate correction? (2) What pain and function levels do patients experience after lateral opening-wedge osteotomy? (3) What are the nonunion, complication, and reoperation rates after lateral opening-wedge osteotomy? Between 2000 and 2010, we performed 40 distal femoral osteotomies. Two knees (two patients) underwent a medial closing-wedge osteotomy and were excluded from the present study. Thirty-eight knees (97%) in 36 patients were lateral opening-wedge varus-producing osteotomies; of those, 31 knees (82%) in 30 patients had followup at a minimum of 2 years (mean, 5 years; SD, 2; range, 2-12 years) and comprised the study population. The indications for osteotomy included symptomatic lateral compartment arthritis with clinical valgus deformity or a cartilage or meniscal defect in the lateral compartment with clinical valgus alignment. The study population was stratified into two groups based on reason for osteotomy: patients with isolated symptomatic lateral compartment arthritis (arthritis group; 19 knees [61%]) and patients who underwent joint preservation procedures including osteochondral allograft transplantation or meniscal allograft transplantation (joint preservation group; 12 knees [39%]). Data collection from our institution's osteotomy database included patient demographics, lower extremity coronal alignment, and operative details. Pain and function were measured preoperatively and postoperatively using the International Knee Documentation Committee (IKDC) score. Time to radiographic union, complications, and reoperations were recorded. Twenty-one of 31 knees had postoperative radiographic data available for review. Of these, seven of 15 knees in the arthritis group and three of six knees in the joint preservation group were within the correction goal of ± 3° from neutral mechanical alignment. In the arthritis group, the mean IKDC total score improved from 47 (SD, 15) preoperatively to 67 (SD, 10) postoperatively. In the joint preservation group, the mean IKDC total score improved from 36 (SD, 12) preoperatively to 62 (SD, 18) postoperatively. One nonunion occurred in the arthritis group. No postoperative complications were experienced. Ten knees in the arthritis group and six knees in the joint preservation group had additional surgery after the osteotomy, consisting primarily of hardware removal, arthroscopy for cartilage-related conditions, or conversion to arthroplasty. Survivorship at 5 years, with conversion to arthroplasty as the endpoint, was 74% in the arthritis group and 92% in the joint preservation group. Lateral opening-wedge distal femoral osteotomy was less accurate in correction of valgus deformity than expected, but the procedure was associated with improved knee pain and function scores. Our clinical and radiographic results are comparable to published series evaluating medial closing-wedge distal femoral osteotomy. Achieving our desired correction of ± 3° from neutral alignment was clinically difficult. An improved method of preoperative templating and refinement of the intraoperative technique may improve this. Future studies with more patients and longer followup will provide clarity on this topic. Level IV, therapeutic study.
Buell, Thomas J; Buchholz, Avery L; Quinn, John C; Mullin, Jeffrey P; Garces, Juanita; Mazur, Marcus D; Shaffrey, Mark E; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin S
2018-06-16
Pedicle subtraction osteotomy (PSO) is an effective technique to correct fixed sagittal malalignment. A variation of this technique, the "trans-discal" or "extended" PSO (Schwab grade IV osteotomy), involves extending the posterior wedge resection of the index vertebra to include the superior adjacent disc for radical discectomy. The posterior wedge may be resected in asymmetric fashion to correct concurrent global coronal malalignment.This video illustrates the technical nuances of an extended asymmetrical lumbar PSO for adult spinal deformity. A 62-yr-old female with multiple prior lumbar fusions presented with worsening back pain and posture. Preoperative scoliosis X-rays demonstrated severe global sagittal and coronal malalignment (sagittal vertical axis [SVA, C7-plumbline] of 13.5 cm, pelvic incidence [PI] of 60°, lumbar lordosis [LL] of 14° [in kyphosis], pelvic tilt [PT] of 61°, thoracic kyphosis [TK] of 18°, and rightward coronal shift of 9.3 cm). The patient gave informed consent to surgery and for use of her imaging for medical publication. Briefly, surgery first involved transpedicular instrumentation from T10 to S1 with bilateral iliac screw fixation, and then T11-12 and T12-L1 Smith-Petersen osteotomies were performed. Next, an extended asymmetrical L4 PSO was performed and a 12° lordotic cage (9 × 14 × 40 mm) was placed at the PSO defect. Rods were placed from T10 to iliac bilaterally, and accessory supplemental rods spanning the PSO were attached. Postoperative scoliosis X-rays demonstrated improved alignment: SVA 5.5 cm, PI 60°, LL 55°, PT 36°, TK 37°, and 3.7 cm of rightward coronal shift. The patient had uneventful recovery.
ROSAT Observations of Solar Wind Charge Exchange with the Lunar Exosphere
NASA Technical Reports Server (NTRS)
Collier, Michael R.; Snowden, S. L.; Benna, M.; Carter, J. A.; Cravens, T. E.; Hills, H. Kent; Hodges, R. R.; Kuntz, K. D.; Porter, F. Scott; Read, A.;
2012-01-01
We analyze the ROSAT PSPC soft X-ray image of the Moon taken on 29 June 1990 by examining the radial profile of the count rate in three wedges, two wedges (one north and one south) 13-32 degrees off (19 degrees wide) the terminator towards the dark side and one wedge 38 degrees wide centered on the anti-solar direction. The radial profiles of both the north and the south wedges show substantial limb brightening that is absent in the 38 degree wide antisolar wedge. An analysis of the count rate increase associated with the limb brightening shows that its magnitude is consistent with that expected due to solar wind charge exchange (SWCX) with the tenuous lunar atmosphere. Along with Mars, Venus, and Earth, the Moon represents another solar system body at which solar wind charge exchange has been observed. This technique can be used to explore the solar wind-lunar interaction.
Hemi-wedge osteotomy in the management of large angular deformities around the knee joint.
El-Alfy, Barakat Sayed
2016-08-01
Angular deformity around the knee joint is a common orthopedic problem. Many options are available for the management of such problem with varying degrees of success and failure. The aim of the present study was to assess the results of hemi-wedge osteotomy in the management of big angular deformities about the knee joint. Twenty-eight limbs in 21 patients with large angular deformities around the knee joint were treated by the hemi-wedge osteotomy technique. The ages ranged from 12 to 43 years with an average of 19.8 years. The deformity ranged from 20° to 40° with a mean of 30.39° ± 5.99°. The deformities were genu varum in 12 cases and genu valgum in 9 cases. Seven cases had bilateral deformities. Small wedge was removed from the convex side of the bone and put in the gap created in the other side after correction of the deformity. At the final follow-up, the deformity was corrected in all cases except two. Full range of knee movement was regained in all cases. The complications included superficial wound infection in two cases, overcorrection in one case, pain along the lateral aspect of the knee in one case and recurrence of the deformity in one case. No cases were complicated by nerve injury or vascular injury. Hemi-wedge osteotomy is a good method for treatment of deformities around the knee joint. It can correct large angular deformities without major complications.
Wedge cutting of mild steel by CO 2 laser and cut-quality assessment in relation to normal cutting
NASA Astrophysics Data System (ADS)
Yilbas, B. S.; Karatas, C.; Uslan, I.; Keles, O.; Usta, Y.; Yilbas, Z.; Ahsan, M.
2008-10-01
In some applications, laser cutting of wedge surfaces cannot be avoided in sheet metal processing and the quality of the end product defines the applicability of the laser-cutting process in such situations. In the present study, CO 2 laser cutting of the wedge surfaces as well as normal surfaces (normal to laser beam axis) is considered and the end product quality is assessed using the international standards for thermal cutting. The cut surfaces are examined by the optical microscopy and geometric features of the cut edges such as out of flatness and dross height are measured from the micrographs. A neural network is introduced to classify the striation patterns of the cut surfaces. It is found that the dross height and out of flatness are influenced significantly by the laser output power, particularly for wedge-cutting situation. Moreover, the cut quality improves at certain value of the laser power intensity.
High-precision processing and detection of the high-caliber off-axis aspheric mirror
NASA Astrophysics Data System (ADS)
Dai, Chen; Li, Ang; Xu, Lingdi; Zhang, Yingjie
2017-10-01
To achieve the efficient, controllable, digital processing and high-precision detection of the high-caliber off-axis aspheric mirror, meeting the high-level development needs of the modern high-resolution, large field of space optical remote sensing camera, we carried out the research on high precision machining and testing technology of off-axis aspheric mirror. First, we forming the off-axis aspheric sample with diameter of 574mm × 302mm by milling it with milling machine, and then the intelligent robot equipment was used for off-axis aspheric high precision polishing. Surface detection of the sample will be proceed with the off-axis aspheric contact contour detection technology and offaxis non-spherical surface interference detection technology after its fine polishing using ion beam equipment. The final surface accuracy RMS is 12nm.
NASA Astrophysics Data System (ADS)
Fukuchi, R.; Yamaguchi, A.; Ito, H.; Yamamoto, Y.; Ashi, J.
2017-12-01
The Nankai accretionary wedge has been developed by subduction of the Philippine Sea Plate beneath the Eurasian and Amur Plate, accompanying forearc basin development upon inner wedge. To evaluate the evolutionary processes of the Nankai inner accretionary wedge, we performed vitrinite reflectance analysis and detrital zircon U-Pb age dating using cuttings retrieved from the Integrated Ocean Drilling Program (IODP) Site C0002 located within the Kumano Basin and penetrates the inner accretionary wedge down to 3058.5 m below the seafloor (mbsf). Although Ro values of vitrinite reflectance tend to increase with depth, there are two reversals (1300-1500 mbsf and 2400-2600 mbsf) of Ro values. The youngest detrital zircon U-Pb age of the cuttings from 2600.5 mbsf is 7.41 Ma, which is obviously younger than shipboard nannofossil ages (9.56-10.54 Ma) at 2245.5 mbsf. Both Ro values and the youngest detrital zircon U-Pb ages show a reversal between 2400-2600 mbsf, suggesting the existence of a thrust fault with sufficient displacement to offset both paleothermal structure and sediment age. Despite similar depositonal age and paleogeothermal gradient, lithofacies in the hanging- and footwall of the 2400-2600 mbsf thrust fault are different; volcaniclastic sediments are rare in the footwall. The lack of volcaniclastic sediments corresponding to the Middle Shikoku Basin facies in the footwall of the thrust suggests that sediments below 2600 mbsf have similar sedimentation background to that of present off-Muroto input site sediments. Thus, our synthesized model of tectonic evolutionary process of deep portion of the Nankai inner accretionary wedge is as follows: 1) 4 Ma: hemipelagic sediments, which deposited similar environment of present off-Muroto input, have accreted ( 4 Ma corresponds to the age of unconformity between forearc basin and accretionary prism (Kinoshita et al., 2009)). 2) 2 Ma: The megasplay fault was activated (Strasser et al., 2009), and Site C0002 sediments moved into inner wedge. Moving direction of the Philippine Sea Plate became NNW to WNW (Kamata and Kodama, 1999). 3) present: inner accretionary wedge has been buried with formation of Kumano forearc basin. Sediments existed offshore of the 4 Ma source area of Site C0002 have moved to off-Muroto input with the motion of the Philippine Sea Plate.
Achieving fixation in glenoids with superior wear using reverse shoulder arthroplasty.
Roche, Christopher P; Stroud, Nicholas J; Martin, Brian L; Steiler, Cindy A; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Dipaola, Matthew J
2013-12-01
Superior glenoid wear is a common challenge with reverse shoulder arthroplasty and, if left uncorrected, can result in superior glenoid tilt, which increases the risk of aseptic glenoid loosening. This study evaluates the impact of an E2 superior defect on reverse shoulder glenoid fixation in composite scapulae after correction of glenoid tilt by use of 2 different glenoid reaming techniques: eccentric reaming and off-axis reaming. A superior glenoid defect was created in 14 composite scapulae. The superior defect was corrected by 2 different glenoid reaming techniques: (1) eccentric reaming with implantation of a standard glenoid baseplate and (2) off-axis reaming with implantation of a superior-augment glenoid baseplate. Each corrected superior-defect scapula was then cyclically loaded (along with a control group consisting of 7 non-worn scapulae) for 10,000 cycles at 750 N; glenoid baseplate displacement was measured for each group to quantify fixation before and after cyclic loading. Regardless of the glenoid reaming technique or the glenoid baseplate type, each standard and superior-augment glenoid baseplate remained well fixed in this superior-defect model scenario after cyclic loading. No differences in baseplate displacement were observed either before or after cyclic loading between groups. Our results suggest that either glenoid reaming technique may be used to achieve fixation in the clinically challenging situation of superior wear with reverse shoulder arthroplasty. Basic science, biomechanical study. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Wide acceptance angle, high concentration ratio, optical collector
NASA Technical Reports Server (NTRS)
Kruer, Mark Arthur (Inventor)
1990-01-01
The invention is directed to an optical collector requiring a wide acceptance angle, and a high concentration ratio. The invention is particularly adapted for use in solar collectors of cassegrain design. The optical collector system includes a parabolic circular concave primary mirror and a hyperbolic circular convex secondary mirror. The primary mirror includes a circular hole located at its center wherein a solar collector is located. The mirrored surface of the secondary mirror has three distinct zones: a center circle, an on-axis annulus, and an off-axis section. The parabolic shape of the primary mirror is chosen so that the primary mirror reflects light entering the system on-axis onto the on-axis annulus. A substantial amount of light entering the system off-axis is reflected by the primary mirror onto either the off-axis section or onto the center circle. Subsequently, the off-axis sections reflect the off-axis light toward the solar collector. Thus, off-axis light is captured which would otherwise be lost to the system. The novelty of the system appears to lie in the configuration of the primary mirror which focuses off-axis light onto an annular portion of the secondary mirror to enable capture thereof. This feature results in wide acceptance angle and a high concentration ratio, and also compensates for the effects of non-specular reflection, and enables a cassegrain configuration to be used where such characteristics are required.
78 FR 39633 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-02
...We propose to supersede three existing airworthiness directives (ADs) that apply to The Boeing Company Model 757-200, - 200PF, and -200CB series airplanes. The existing ADs currently require repetitive inspections and audible tap tests of the upper and lower skins of the trailing edge wedges on certain slats, and related investigative and corrective actions if necessary. Since we issued these ADs, we have received reports of slats disbonding on airplanes on which the terminating actions of the existing ADs were completed and also reports of slats disbonding on airplanes outside of the applicability of the existing ADs. This proposed AD would require a determination of the type of trailing edge wedges of the leading edge slats, repetitive inspections on certain trailing edge wedges for areas of skin-to-core disbonding, and corrective actions if necessary. This proposed AD would also provide an optional terminating action for the repetitive inspections. This AD would revise the applicability of the existing ADs to include additional airplanes. We are proposing this AD to prevent delamination of the trailing edge wedge of the leading edge slats, possible loss of pieces of the trailing edge wedge assembly during flight, reduction of the reduced maneuver and stall margins, and consequent reduced controllability of the airplane.
Trapezial osteotomy for the treatment of trapezial dysplasia.
El-Mahy, Mohammed M
2013-11-01
Dysplastic trapezium is a condition that is characterized by an exaggerated slant (slope) of the distal articular surface of the trapezium in relation to the axis of the second metacarpal. Usually, it becomes evident in the late teens and early 20s with proximolateral subluxation of the base of the first metacarpal and is associated with pain at the base of the thumb. It is more common in the dominant hand of women, but can affect both hands and either sex. The condition can be progressively painful and incapacitating, and those patients will require early support with medical treatment. Surgical management is indicated in persistent cases. In this study, we aimed at correcting theabnormal trapezial tilt in nonarthritic trapeziometacarpal joints by a dorsoradial open wedge osteotomy and bone graft, restoring the normal biomechanics around the joint, abolishing the abnormal loads sustained by the ligaments, and aiming to prevent the development of arthritic changes.
Determination of the technical constants of laminates in oblique directions
NASA Technical Reports Server (NTRS)
Vidouse, F.
1979-01-01
An off-axis tensile test theory based on Hooke's Law is applied to glass fiber reinforced laminates. A corrective parameter dependent on the characteristics of the strain gauge used is introduced by testing machines set up for isotropic materials. Theoretical results for a variety of strain gauges are compared with those obtained by a finite element method and with experimental results obtained on laminates reinforced with glass.
Practical wavelength calibration considerations for UV-visible Fourier-transform spectroscopy.
Salit, M L; Travis, J C; Winchester, M R
1996-06-01
The intrinsic wavelength scale in a modern reference laser-controlled Michelson interferometer-sometimes referred to as the Connes advantage-offers excellent wavelength accuracy with relative ease. Truly superb wavelength accuracy, with total relative uncertainty in line position of the order of several parts in 10(8), should be within reach with single-point, multiplicative calibration. The need for correction of the wavelength scale arises from two practical effects: the use of a finite aperture, from which off-axis rays propagate through the interferometer, and imperfect geometric alignment of the sample beam with the reference beam and the optical axis of the moving mirror. Although an analytical correction can be made for the finite-aperture effect, calibration with a trusted wavelength standard is typically used to accomplish both corrections. Practical aspects of accurate calibration of an interferometer in the UV-visible region are discussed. Critical issues regarding accurate use of a standard external to the sample source and the evaluation and selection of an appropriate standard are addressed. Anomalous results for two different potential wavelength standards measured by Fabry-Perot interferometry (Ar II and (198)Hg I) are observed.
Lei, Yu; Lin, Guan-yu
2013-01-01
Tandem gratings of double-dispersion mount make it possible to design an imaging spectrometer for the weak light observation with high spatial resolution, high spectral resolution, and high optical transmission efficiency. The traditional tandem Wadsworth mounting is originally designed to match the coaxial telescope and large-scale imaging spectrometer. When it is used to connect the off-axis telescope such as off-axis parabolic mirror, it presents lower imaging quality than to connect the coaxial telescope. It may also introduce interference among the detector and the optical elements as it is applied to the short focal length and small-scale spectrometer in a close volume by satellite. An advanced tandem Wadsworth mounting has been investigated to deal with the situation. The Wadsworth astigmatism-corrected mounting condition for which is expressed as the distance between the second concave grating and the imaging plane is calculated. Then the optimum arrangement for the first plane grating and the second concave grating, which make the anterior Wadsworth condition fulfilling each wavelength, is analyzed by the geometric and first order differential calculation. These two arrangements comprise the advanced Wadsworth mounting condition. The spectral resolution has also been calculated by these conditions. An example designed by the optimum theory proves that the advanced tandem Wadsworth mounting performs excellently in spectral broadband.
Off-axis astigmatism in the isolated chicken crystalline lens.
Maier, Felix; Wahl, Siegfried; Schaeffel, Frank
2016-12-01
The chicken eye was previously found to have little off-axis astigmatism which is not explained by its special corneal shape but rather by the optical properties of the crystalline lens. To learn more about lens design, we studied off-axis astigmatism in the chicken lens in situ and compared it to a glass lens of similar power but with homogenous refractive index. After euthanasia, enucleated eye balls were cut in the equatorial plane right behind the scleral ossicles. The anterior segment was placed in a water-filled chamber. Several thin laser beams were projected in two perpendicular meridians through the lens under various eccentricities and the focal lengths were determined. Off-axis astigmatism across the horizontal visual field was determined as the differences in power in the two meridians. The same procedure was used for the glass lens. On-axis, the chicken crystalline lens had slightly more power in the vertical than in the horizontal meridian (-2.8±0.7D (SEM)). Astigmatism flipped sign and increased with eccentricity to reach +6.1±2.1D (SEM) at 33.5deg off-axis, as expected from off-axis astigmatism. Even though this value appears high, it was still 2.5 times lower than in the glass lens. A ZEMAX model of a lens with a homogeneous index and with surface profiles taken of the natural chicken lens revealed even higher levels of off-axis astigmatism. Obviously, the natural chicken lens displays much less off-axis astigmatism than a glass lens with similar power. Since its shape does not explain the low off-axis astigmatism, it must be due to a refined internal refractive index structure. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pinzuti, Paul; Humler, Eric; Manighetti, Isabelle; Gaudemer, Yves
2013-08-01
The temporal evolution of the mantle melting processes in the Asal Rift is evaluated from the chemical composition of 56 new lava flows sampled along 10 km of the rift axis and 9 km off-axis (i.e., erupted within the last 620 kyr). Petrological and primary geochemical results show that most of the samples of the inner floor of the Asal Rift are affected by plagioclase accumulation. Trace element ratios and major element compositions corrected for mineral accumulation and crystallization show a symmetric pattern relative to the rift axis and preserved a clear signal of mantle melting depth variations. While FeO, Fe8.0, Zr/Y, and (Dy/Yb)N decrease from the rift shoulders to the rift axis, SiO2, Na/Ti, Lu/Hf increase and Na2O and Na8.0 are constant across the rift. These variations are qualitatively consistent with shallow melting beneath the rift axis and deeper melting for off-axis lava flows. Na8.0 and Fe8.0 contents show that beneath the rift axis, melting paths are shallow, from 81 ± 4 to 43 ± 5 km. These melting paths are consistent with adiabatic melting in normal-temperature fertile asthenosphere, beneath an extensively thinned mantle lithosphere. On the contrary, melting on the rift shoulders (from 107 ± 7 to 67 ± 8 km) occurred beneath thicker lithosphere, requiring a mantle solidus temperature 100 ± 40°C hotter. In this geodynamic environment, the calculated rate of lithospheric thinning appears to be 4.0 ± 2.0 cm yr-1, a value close to the mean spreading rate (2.9 ± 0.2 cm yr-1) over the last 620 kyr.
Optical vortices with starlight
NASA Astrophysics Data System (ADS)
Anzolin, G.; Tamburini, F.; Bianchini, A.; Umbriaco, G.; Barbieri, C.
2008-09-01
Aims: In this paper we present our first observations at the Asiago 122 cm telescope of ℓ = 1 optical vortices generated with starlight beams. Methods: We used a fork-hologram blazed at the first diffraction order as a phase modifying device. The multiple system Rasalgethi (α Herculis) in white light and the single star Arcturus (α Bootis) through a 300 Å bandpass were observed using a fast CCD camera. In the first case we could adopt the Lucky Imaging approach to partially correct for seeing effects. Results: For both stars, the optical vortices could be clearly detected above the smearing caused by the mediocre seeing conditions. The profiles of the optical vortices produced by the beams of the two main components of the α Her system are consistent with numerically simulated on-axis and off-axis optical vortices. The optical vortices produced by α Boo can also be reproduced by numerical simulations. Our experiments confirm that the ratio between the intensity peaks of an optical vortex can be extremely sensitive to off-axis displacements of the beam. Conclusions: Our results give insights for future astronomical applications of optical vortices both for space telescopes and ground-based telescopes with good seeing conditions and adaptive optics devices. The properties of optical vortices can be used to perform high precision astrometry and tip/tilt correction of the isoplanatic field. We are now designing a ℓ = 2 optical vortex coronagraph around a continuous spiral phase plate. We also point out that optical vortices could find extremely interesting applications also in the infrared and radio wavelengths.
Are the new starting block facilities beneficial for backstroke start performance?
de Jesus, Karla; de Jesus, Kelly; Abraldes, J Arturo; Medeiros, Alexandre Igor Araripe; Fernandes, Ricardo J; Vilas-Boas, João Paulo
2016-01-01
We aimed to analyse the handgrip positioning and the wedge effects on the backstroke start performance and technique. Ten swimmers completed randomly eight 15 m backstroke starts (four with hands on highest horizontal and four on vertical handgrip) performed with and without wedge. One surface and one underwater camera recorded kinematic data. Standardised mean difference (SMD) and 95% confidence intervals (CI) were used. Handgrip positioning did not affect kinematics with and without wedge use. Handgrips horizontally positioned and feet over wedge displayed greater knee angular velocity than without it (SMD = -0.82; 95% CI: -1.56, -0.08). Hands vertically positioned and feet over wedge presented greater take-off angle (SMD = -0.81; 95% CI: -1.55, -0.07), centre of mass (CM) vertical positioning at first water contact (SMD = -0.97; 95% CI: -1.87, -0.07) and CM vertical velocity at CM immersion (SMD = 1.03; 95% CI: 0.08, 1.98) when comparing without wedge use. Swimmers extended the hip previous to the knee and ankle joints, except for the variant with hands vertically positioned without wedge (SMD = 0.75; 95% CI: -0.03, 1.53). Swimmers should preserve biomechanical advantages achieved during flight with variant with hands vertically positioned and wedge throughout entry and underwater phase.
Sawicki, R.H.; Sweatt, W.
1985-11-21
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and provides for adjustably bending the light reflecting surface into one of different curvatures depending upon the astigmatism to be corrected and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment to the reinforced side edges of the light reflecting surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawicki, R.H.; Sweatt, W.
1985-11-21
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and provides for adjustably bending the light reflecting surface into one of different curvatures depending upon the astigmatism to be corrected and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment tomore » the reinforced side edges of the light reflecting surface.« less
Astronomical Near-neighbor Detection with a Four-quadrant Phase Mask (FQPM) Coronagraph
NASA Technical Reports Server (NTRS)
Haguenauer, Pierre; Serabyn, Eugene; Mennesson, Bertrand; Wallace, James K.; Gappinger, Robert O.; Troy, Mitchell; Bloemhof, Eric E.; Moore, Jim; Koresko, Chris D.
2006-01-01
Direct detection of planets around nearby stars requires the development of high-contrast imaging techniques, because of their very different respective fluxes. We thus investigated the innovative coronagraphic approach based on the use of a four-quadrant phase mask (FQPM). Simulations showed that, combined with high-level wavefront correction on an unobscured off-axis section of a large telescope, this method allows high-contrast imaging very close to stars, with detection capability superior to that of a traditional coronagraph. A FQPM instrument was thus built to test the feasibility of near-neighbor observations with our new off-axis approach on a ground-based telescope. In June 2005, we deployed our instrument to the Palomar 200-inch telescope, using existing facilities as much as possible for rapid implementation. In these initial observations, using data processing techniques specific to FQPM coronagraphs, we reached extinction levels of the order of 200:1. Here we discuss our simulations and on-sky results obtained so far.
Design of a high-numerical-aperture digital micromirror device camera with high dynamic range.
Qiao, Yang; Xu, Xiping; Liu, Tao; Pan, Yue
2015-01-01
A high-NA imaging system with high dynamic range is presented based on a digital micromirror device (DMD). The DMD camera consists of an objective imaging system and a relay imaging system, connected by a DMD chip. With the introduction of a total internal reflection prism system, the objective imaging system is designed with a working F/# of 1.97, breaking through the F/2.45 limitation of conventional DMD projection lenses. As for the relay imaging system, an off-axis design that could correct off-axis aberrations of the tilt relay imaging system is developed. This structure has the advantage of increasing the NA of the imaging system while maintaining a compact size. Investigation revealed that the dynamic range of a DMD camera could be greatly increased, by 2.41 times. We built one prototype DMD camera with a working F/# of 1.23, and the field experiments proved the validity and reliability our work.
Three-dimensional Distribution of Azimuthal and Radial Anisotropy in the Japan Subduction
NASA Astrophysics Data System (ADS)
Ishise, M.; Kawakatsu, H.; Shiomi, K.
2014-12-01
Seismic anisotropy has close relationships with past and present tectonic and dynamic processes. Therefore, detailed description of seismic anisotropy of subduction zones provides important information for our understanding of the subduction system. The most common method of detecting anisotropy is the S-wave splitting measurement. However, conventional S-wave splitting analysis is not an appropriate way to investigate anisotropy in the mantle and slab because the technique has no vertical resolution. Thus, we have improved common traveltime tomography to estimate three-dimensional anisotropic structures of P-wave, assuming that the modeling space is composed of weakly anisotropic medium with a hexagonal symmetry about a horizontal axis (Ishise & Oda, 2005, JGR; Ishise & Oda, 2008, PEPI). Recently, we extended the anisotropic tomography for P-wave radial anisotropy with vertical hexagonal symmetry axis (Ishise & Kawakatsu, 2012 JpGU). In this study, we expand the study area of our previous regional analyses of P-wave azimuthal and radial anisotropic tomography (Ishise & Oda, 2005; Ishise & Kawakatsu, 2012, JpGU; Ishise et al., 2012, SSJ) using Hi-net arrival time data and examine the subduction system around the Japan islands, where two trenches with different strike directions and plate junction are included. Here are some of the remarkable results associated with the PAC slab and mantle structure. (1) N-S-trending fast axis of P-wave anisotropy is dominant in the PAC slab. (2) the mantle wedge shows trench-normal anisotropy across the trench-trench junction. (3) horizontal velocity (PH) tends to be faster than vertical velocity (PV) in the slab. (4) PV tends to be faster than PH in the mantle wedge. The characteristics of the obtained azimuthal and radial anisotropy of the PAC slab and the mantle wedge qualitatively consistent with heterogeneous plate models (e.g., Furumura & Kennet, 2005) and numerical simulations of mantle flow (Morishige & Honda, 2011; 2013). In addition, the azimuthal anisotropy in the PAC slab that we obtained is subparallel to that in the PAC plate before subducting (e.g., Shimamura et al., 1983). Therefore, we suggest that the slab anisotropy is "frozen anisotropy", which is attributed to the episode before subduction, and mantle wedge anisotropy reflects present dynamics.
Off-axis reflective optical apparatus
NASA Technical Reports Server (NTRS)
Ames, Lawrence L. (Inventor); Leary, David F. (Inventor); Mammini, Paul V. (Inventor)
2005-01-01
Embodiments of the present invention are directed to a simple apparatus and a convenient and accurate method of mounting the components to form an off-axis reflective optical apparatus such as a collimator. In one embodiment, an off-axis reflective optical apparatus comprises a mounting block having a ferrule holder support surface and an off-axis reflector support surface which is generally perpendicular to the ferrule holder support surface. An optical reflector is mounted on the off-axis reflector support surface and has a reflected beam centerline. The optical reflector has a conic reflective surface and a conic center. A ferrule holder is mounted on the ferrule holder support surface. The ferrule holder provides a ferrule for coupling to an optical fiber and orienting a fiber tip of the optical fiber along a fiber axis toward the optical reflector. The fiber axis is nonparallel to the reflected beam centerline. Prior to mounting the optical reflector to the off-axis reflector support surface and prior to mounting the ferrule holder to the ferrule holder support surface, the optical reflector is movable on the off-axis reflector surface and the ferrule holder is movable on the ferrule holder support surface to align the conic center of the optical reflector with respect to the fiber tip of the optical fiber, and the apparatus has at least one of the following features: (1) the optical reflector is movable on the off-axis reflector support surface to adjust a focus of the fiber tip with respect to the optical reflector, and (2) the ferrule holder is movable on the ferrule holder support surface to adjust the focus of the fiber tip with respect to the optical reflector.
Study on off-axis detection of pulsed laser in atmosphere
NASA Astrophysics Data System (ADS)
Liang, Weiwei
2018-02-01
Laser communication, designation, and ranging are point to point and have a high degree of specificity, current laser detection, such as laser warning receiver system, could detect the scattering laser from the off-axis distance by scattering track on natural aerosols, which is helpful to locate the laser source. However, the intensity of the scattering laser is extremely weak and affected by many factors, in order to evaluate the detection characteristic, a simplified model of off-axis detection for scattering laser in the lower atmosphere based on the Mie scattering theory is presented in this paper, the performances of the off-axis laser detection in different conditions such as off-axis distance, visibility, incidence angle, and delay time are investigated.
NASA Astrophysics Data System (ADS)
Perfit, M. R.; Walters, R. L.
2014-12-01
High spatial density geochemical data sets from the N-EPR and S-JdFR are used to re-evaluate the across-axis geochemical variations in major and trace elements at mid-ocean ridges (MORs). At two axial melt lens (AML) segments, north and south, at the 9-10°N EPR, N-MORB MgO varies across-axis from the most primitive above the AML to more evolved away from the axis. This trend is distinct at the northern (magmatically more robust) segment with an axial MgO range of 8-9 wt% and off-axis (>2km) range of 6.5-8 wt%. This decrease is also reflected in E-MORB MgO variation. There is more variability at the southern segment but, off-axis progression to more evolved MgO is still evident. Interestingly, the Cleft segment, JdFR, displays similar geochemical behavior to the EPR with an axial MgO range of 7-8.5 wt% and off-axis (>2km) range of 6-7.5 wt%. EPR geochemical studies over the past 30 years have described models of upper crustal accumulation ranging from eruptions limited to the axis, to temporal variation in the composition of magma in the AML, to multiple eruption sites across the ridge crest and flanks (<5km). Eruptions limited to the axis, with topographically controlled flow off-axis, cannot reproduce the observed off-axis change to more evolved N-MORB. Time-dependence could explain one instance of evolved lavas off-axis but, similar geochemical behavior is observed at two separate AML segments. Multiple instances of consistent compositional variability at multiple AML segments, and at different ridges, point to a common process of crustal accretion at MORs. In light of recent geophysical discoveries of Off-axis AMLs (OAMLs) at the EPR and JdFR, we propose that the trend of more evolved lavas for the majority of N-MORB lavas with distance from the axis is controlled by thermal distribution in the underlying crystal mush zone (CMZ). Higher magma flux beneath the axis facilitates higher temperatures and high porosity melt pathways, reducing crustal residence times, and erupting more primitive lava compositions. OAMLs at the edges of the CMZ, where it is cooler, feed more evolved off-axis eruptions. Lower magma flux at the edges increases crustal residence time and the extent to which magmas crystallize. OAMLs outside of the CMZ host magmas that may escaped any central mixing and erupt a greater range of compositions.
King, Mark; Hau, Agnes; Blenkinsop, Glen
2017-07-01
Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball-racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 "flat" one-handed backhand groundstrokes. Off-longitudinal axis ball-racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball-racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.
Chiba, Ko; Yonekura, Akihiko; Miyamoto, Takashi; Osaki, Makoto; Chiba, Goji
2017-03-01
Tibial condylar valgus osteotomy (TCVO) is a type of opening-wedge high tibial osteotomy for advanced medial knee osteoarthritis (OA) with subluxated lateral joint. We report the concept, the current surgical technique with a locking plate, and the short-term clinical and radiological results of this procedure. 11 knees with medial OA and a widened lateral joint were treated by TCVO (KL stage III: 6, IV: 5). In this procedure, by the L-shaped osteotomy from the medial side of the proximal tibia to the intercondylar eminence and the valgus correction, lateralization of the mechanical axis and reduction of the subluxated lateral joint are obtained with early postoperative weight-bearing. Before, 6 months, 1, and 5 years after the operation, a visual analog scale (VAS), the Western Ontario and McMaster Universities Arthritis Index (WOMAC), alignment of the lower extremity, and congruency and stability of the femorotibial joint were investigated. The VAS improved from an average of 73 mm to 13 mm, and the total WOMAC score from 52 to 14 before to 5 years after the operation, respectively. The mechanical axis changed from 1 to 60%, and the FTA changed from 186° to 171°. The joint line convergence angle (JLCA) changed from 6° to 1°, and the angle difference of JLCA between varus and valgus stress improved from 8° to 4° after the procedure. Improvements in pain and activities of daily living were observed by TCVO along with valgus correction of the lower extremity and stabilization of the femorotibial joint.
NASA Astrophysics Data System (ADS)
Nishizawa, Azusa; Kaneda, Kentaro; Oikawa, Mitsuhiro; Horiuchi, Daishi; Fujioka, Yukari; Okada, Chiaki
2017-06-01
The Ryukyu (Nansei-Shoto) island arc-trench system, southwest of Japan, is formed by the subduction of the Philippine Sea (PHS) plate. Among the subduction zones surrounding the Japan Islands, the Ryukyu arc-trench system is unique in that its backarc basin, the Okinawa Trough, is the area with current extensively active rifting. The length of the trench is around 1400 km, and the geological and geophysical characteristics vary significantly along the trench axis. We conducted multichannel seismic (MCS) reflection and wide-angle seismic surveys to elucidate the along-arc variation in seismic structures from the island arc to the trench regions, shooting seven seismic lines across the arc-trench system and two along-arc lines in the island arc and the forearc areas. The obtained P-wave velocity models of the Ryukyu arc crust were found to be heterogeneous (depending on the seismic lines), but they basically consist of upper, middle, and lower crusts, indicating a typical island arc structure. Beneath the bathymetric depressions cutting the island arc—for example, the Kerama Gap and the Miyako Saddle—the MCS record shows many across-arc normal faults, which indicates the presence of an extensional regime along the island arc. In the areas from the forearc to the trench, the subduction of the characteristic seafloor features on the PHS plate affects seismic structures; the subducted bathymetric high of the Amami Plateau is detected in the northern trench: the Luzon-Okinawa fracture zone beneath the middle and southern trenches. There are low-velocity (< 4.5 km/s) wedges along the forearc areas, except for off Miyako-jima Island. The characteristic high gravity anomaly at the forearc off Miyako-jima Island is caused not by a bathymetric high of a large-scale accretionary wedge but by shallower materials with a high P-wave velocity of 4.5 km/s.[Figure not available: see fulltext.
Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.
Chang, Liyun; Chui, Chen-Shou; Ding, Hueisch-Jy; Hwang, Ing-Ming; Ho, Sheng-Yow
2012-09-21
The EBT2 film together with a flatbed scanner is a convenient dosimetry QA tool for verification of clinical radiotherapy treatments. However, it suffers from a relatively high degree of uncertainty and a tedious film calibration process for every new lot of films, including cutting the films into several small pieces, exposing with different doses, restoring them back and selecting the proper region of interest (ROI) for each piece for curve fitting. In this work, we present a percentage depth dose (PDD) method that can accurately calibrate the EBT2 film together with the scanner non-uniformity correction and provide an easy way to perform film dosimetry. All films were scanned before and after the irradiation in one of the two homemade 2 mm thick acrylic frames (one portrait and the other landscape), which was located at a fixed position on the scan bed of an Epson 10 000XL scanner. After the pre-irradiated scan, the film was placed parallel to the beam central axis and sandwiched between six polystyrene plates (5 cm thick each), followed by irradiation of a 20 × 20 cm² 6 MV photon beam. Two different beams on times were used on two different films to deliver a dose to the film ranging from 32 to 320 cGy. After the post-irradiated scan, the net optical densities for a total of 235 points on the beam central axis on the films were auto-extracted and compared with the corresponding depth doses that were calculated through the measurement of a 0.6 cc farmer chamber and the related PDD table to perform the curve fitting. The portrait film location was selected for routine calibration, since the central beam axis on the film is parallel to the scanning direction, where non-uniformity correction is not needed (Ferreira et al 2009 Phys. Med. Biol. 54 1073-85). To perform the scanner non-uniformity calibration, the cross-beam profiles of the film were analysed by referencing the measured profiles from a Profiler™. Finally, to verify our method, the films were exposed to 60° physical wedge fields and the compositive fields, and their relative dose profiles were compared with those from the water phantom measurement. The fitting uncertainty was less than 0.5% due to the many calibration points, and the overall calibration uncertainty was within 3% for doses above 50 cGy, when the average of four films were used for the calibration. According to our study, the non-uniformity calibration factor was found to be independent of the given dose for the EBT2 film and the relative dose differences between the profiles measured by the film and the Profiler were within 1.5% after applying the non-uniformity correction. For the verification tests, the relative dose differences between the measurements by films and in the water phantom, when the average of three films were used, were generally within 3% for the 60° wedge fields and compositive fields, respectively. In conclusion, our method is convenient, time-saving and cost-effective, since no film cutting is needed and only two films with two exposures are needed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawicki, R.H.; Sweatt, W.
1987-03-03
An apparatus is described for correcting for astigmatism in a light beam reflected off of a light reflecting surface, comprising: (a) a first means defining a flat, rectangular light reflecting surface which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis. The first means is configured so that the light reflecting surface can be adjustably bent into the selected cylindrical curvature by applying a particular bending moment to the first means with respect to the surface, depending upon the curvature desired. The first means includes an integrally formed body member havingmore » a main plate-like segment including a front fact defining the light reflecting surface and a pair of spaced-apart flange segments extending rearwardly of the main segment; and (b) second means acting on the first means for adjustably bending the light reflecting surface into a particular selected one of the different cylindrical curvatures, depending upon the astigmatism to be corrected for.« less
Device for wavefront correction in an ultra high power laser
Ault, Earl R.; Comaskey, Brian J.; Kuklo, Thomas C.
2002-01-01
A system for wavefront correction in an ultra high power laser. As the laser medium flows past the optical excitation source and the fluid warms its index of refraction changes creating an optical wedge. A system is provided for correcting the thermally induced optical phase errors.
NASA Astrophysics Data System (ADS)
Yamamoto, R.; Hino, R.; Kido, M.; Osada, Y.; Honsho, C.
2017-12-01
Since postseismic deformation across 2011 Tohoku-oki Earthquake is strongly affected by viscoelastic relaxation, it is difficult to identify postseismic slip from onshore (e.g. GNSS) and offshore (e.g. GPS-Acoustic: GPS-A) observations. To track postseismic slip directly, we installed acoustic ranging instruments across the axis of the central Japan Trench, off-Miyagi, near the region of large coseismic motion (>50 m) happened during 2011 Tohoku-oki Earthquake.Direct Path Ranging (DPR) measures two-way travel time between a pair of transponders settled on the seafloor. Baseline length can be obtained from calculating travel time and sound velocity which is corrected for time-varying temperature and pressure beforehand. We further made correction for the motion of acoustic elements due to attitude changes of the instruments. Baseline changes can be detected precisely by periodic ranging during observation.We have conducted observations during three times (2013, 2014 - 2015, and 2015 - 2016), and revealed that no significant shortenings across the trench axis took place. It follows that no shallow postseismic slip had occurred off-Miyagi, at least from 2013 to 2016. We examined the accuracy of baseline length measurements and can observed 1.0 ppm (1.0 mm for 1 km baseline) errors, which is small enough. Our results are consistent with the postseismic slip distribution model based on GPS-A observations.Acknowledgements: This research is supported by JSPS KAKENHI (26000002). The installation and recovery of instruments were executed during R/V Kairei (KR13-09; KR15-15), R/V Hakuho-maru (KH-13-05; KH-17-J02), R/V Shinsei-maru (KS-14-17; KS-15-03; KS-16-14).
GALACSI integration and functional tests
NASA Astrophysics Data System (ADS)
La Penna, P.; Ströbele, S.; Aller Carpentier, E.; Argomedo, J.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Donaldson, R.; Duchateau, M.; Fedrigo, E.; Gago, F.; Hubin, N.; Quentin, J.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J. L.; Madec, P.-.; Manescau, A.; Mehrgan, L.; Sedghi, B.; Suarez Valles, M.; Soenke, C.; Tordo, S.; Vernet, J.; Zampieri, S.
2014-07-01
GALACSI is the Adaptive Optics (AO) modules of the ESO Adaptive Optics Facility (AOF) that will correct the wavefront delivered to the MUSE Integral Field Spectrograph. It will sense with four 40×40 subapertures Shack-Hartmann wavefront sensors the AOF 4 Laser Guide Stars (LGS), acting on the 1170 voice-coils actuators of the Deformable Secondary Mirror (DSM). GALACSI has two operating modes: in Wide Field Mode (WFM), with the four LGS at 64" off axis, the collected energy in a 0.2"×0.2" pixel will be enhanced by a factor 2 at 750 nm over a Field of View (FoV) of 1'×1' using the Ground Layer AO (GLAO) technique. The other mode, the Narrow Field Mode (NFM), provides an enhanced wavefront correction (Strehl Ratio (SR) of 5% (goal 10%) at 650 nm) but in a smaller FoV (7.5"×7.5"), using Laser Tomography AO (LTAO), with the 4 LGS located closer, at 10" off axis. Before being shipped to Paranal, GALACSI will be first integrated and fully tested in stand-alone, and then moved to a dedicated AOF facility to be tested with the DSM in Europe. At present the module is fully assembled, its main functionalities have been implemented and verified, and AO system tests with the DSM are starting. We present here the main system features and the results of the internal functional tests of GALACSI.
Girshovitz, Pinhas; Frenklach, Irena; Shaked, Natan T
2015-11-01
We propose a new portable imaging configuration that can double the field of view (FOV) of existing off-axis interferometric imaging setups, including broadband off-axis interferometers. This configuration is attached at the output port of the off-axis interferometer and optically creates a multiplexed interferogram on the digital camera, which is composed of two off-axis interferograms with straight fringes at orthogonal directions. Each of these interferograms contains a different FOV of the imaged sample. Due to the separation of these two FOVs in the spatial-frequency domain, they can be fully reconstructed separately, while obtaining two complex wavefronts from the sample at once. Since the optically multiplexed off-axis interferogram is recorded by the camera in a single exposure, fast dynamics can be recorded with a doubled imaging area. We used this technique for quantitative phase microscopy of biological samples with extended FOV. We demonstrate attaching the proposed module to a diffractive phase microscopy interferometer, illuminated by a broadband light source. The biological samples used for the experimental demonstrations include microscopic diatom shells, cancer cells, and flowing blood cells.
Acquisition and replay systems for direct-to-digital holography and holovision
Thomas, Clarence E.; Hanson, Gregory R.
2003-02-25
Improvements to the acquisition and replay systems for direct-to-digital holography and holovision are described. A method of recording an off-axis hologram includes: splitting a laser beam into an object beam and a reference beam; reflecting the reference beam from a reference beam mirror; reflecting the object beam from an illumination beamsplitter; passing the object beam through an objective lens; reflecting the object beam from an object; focusing the reference beam and the object beam at a focal plane of a digital recorder to form an off-axis hologram; digitally recording the off-axis hologram; and transforming the off-axis hologram in accordance with a Fourier transform to obtain a set of results. A method of writing an off-axis hologram includes: passing a laser beam through a spatial light modulator; and focusing the laser beam at a focal plane of a photorefractive crystal to impose a holographic diffraction grating pattern on the photorefractive crystal. A method of replaying an off-axis hologram includes: illuminating a photorefractive crystal having a holographic diffraction grating with a replay beam.
Kinkpe, CV; Onimus, M; Sarr, L; Niane, MM; Traore, MM; Daffe, M; Gueye, AB
2017-01-01
Background: It has been observed that the correction of severe posttuberculous angular kyphosis is still a challenge, mainly because of the neurologic risk. Methods: Nine patients were reviewed after surgery (mean follow-up 18 months). There were 2 thoracic, 4 thoraco-lumbar and 3 lumbar kyphosis. The mean age at surgery was 23. Clinical results were evaluated by the Oswestry Disability Index (ODI) and by the neurologic evaluation. Preoperative, postoperative and final follow-up X-rays were assessed. The surgery included a posterior approach with cord release and correction by transpedicular wedge osteotomy and widening of the spinal canal. Results: Average kyphotic angulation was 72° before surgery, 10° after surgery and 12° at follow-up. Three out of four patients with neural deficit showed improvement. Neurologic complications included a transitory quadriceps paralysis, likely by foraminal compression of the root. Conclusion: A posterior transpedicular wedge osteotomy allows a substantial correction of the kyphosis, more by deflexion than by elongation, with limited neurologic risks. However it is mandatory to widely enlarge the spinal canal on the levels adjacent to the osteotomy, in order to allow the dura to expand backwards. PMID:28567156
Miniaturized spectrometer for stand-off chemical detection
NASA Astrophysics Data System (ADS)
Henning, Patrick F.; Chadha, Suneet; Damren, Richard; Rowe, Rebecca C.; Stevenson, Chuck; Curtiss, Lawrence E.; DiGiuseppe, Thomas G.
2002-02-01
Advanced autonomous detection of both chemical warfare agents and toxic industrial chemicals has long been of major military concern and is becoming an increasingly realistic need. Foster-Miller has successfully designed and demonstrated a high spectral throughput monolithic wedge spectrometer capable of providing early, stand-off detection of chemical threats. Recent breakthrough innovations in IR source technologies, high D* multispectral array detectors, and IR waveguide materials has allowed for the development of a robust, miniature, monolithic infrared spectrometer. Foster-Miller recently demonstrated a high resolution spectrometer operating in the 8 to 12 micron region for chemical agent detection. Results will be presented demonstrating the feasibility of adapting the wedge spectrometer to operate as an upward looking ground sensor for stand-off chemical detection. Our miniaturized spectrometer forms the basis for deploying low cost, lightweight sensors which may be used for reconnaissance missions or delivered to remote locations for unattended operation. The ability of perform passive stand-off infrared chemical agent and chemical emissions detection with a low cost, compact device that can operate autonomously in remote environments has broad applications in both the military and commercial marketplace.
Method for welding an article and terminating the weldment within the perimeter of the article
NASA Technical Reports Server (NTRS)
Snyder, John H. (Inventor); Smashey, Russell W. (Inventor); Boerger, Eric J. (Inventor); Borne, Bruce L. (Inventor)
2000-01-01
An article is welded, as in weld repair of a defect, by positioning a weld lift-off block at a location on the surface of the article adjacent to the intended location of the end of the weldment on the surface of the article. The weld lift-off block has a wedge shape including a base contacting the surface of the article, and an upper face angled upwardly from the base from a base leading edge. A weld pool is formed on the surface of the article by directly heating the surface of the article using a heat source. The heat source is moved relative to the surface of the article and onto the upper surface of the weld lift-off block by crossing the leading edge of the wedge, without discontinuing the direct heating of the article by the heat source. The heating of the article with the heat source is discontinued only after the heat source is directly heating the upper face of the weld lift-off block, and not the article.
Prophylactic Z-plasty - correcting helical rim deformity from wedge excision.
Kim, Peter
2010-09-01
Wedge excision is a popular and well documented surgical method for treating a wide range of skin lesions and cancers of the ear in the general practice setting. In the majority of cases, this is a simple and cosmetically pleasing treatment. However, it may create helical rim deformity. This article describes a simple method of preventing such deformity using prophylactic Z-plasty.
Isolating active orogenic wedge deformation in the southern Subandes of Bolivia
NASA Astrophysics Data System (ADS)
Weiss, Jonathan R.; Brooks, Benjamin A.; Foster, James H.; Bevis, Michael; Echalar, Arturo; Caccamise, Dana; Heck, Jacob; Kendrick, Eric; Ahlgren, Kevin; Raleigh, David; Smalley, Robert; Vergani, Gustavo
2016-08-01
A new GPS-derived surface velocity field for the central Andean backarc permits an assessment of orogenic wedge deformation across the southern Subandes of Bolivia, where recent studies suggest that great earthquakes (>Mw 8) are possible. We find that the backarc is not isolated from the main plate boundary seismic cycle. Rather, signals from subduction zone earthquakes contaminate the velocity field at distances greater than 800 km from the Chile trench. Two new wedge-crossing velocity profiles, corrected for seasonal and earthquake affects, reveal distinct regions that reflect (1) locking of the main plate boundary across the high Andes, (2) the location of and loading rate at the back of orogenic wedge, and (3) an east flank velocity gradient indicative of décollement locking beneath the Subandes. Modeling of the Subandean portions of the profiles indicates along-strike variations in the décollement locked width (WL) and wedge loading rate; the northern wedge décollement has a WL of ~100 km while accumulating slip at a rate of ~14 mm/yr, whereas the southern wedge has a WL of ~61 km and a slip rate of ~7 mm/yr. When compared to Quaternary estimates of geologic shortening and evidence for Holocene internal wedge deformation, the new GPS-derived wedge loading rates may indicate that the southern wedge is experiencing a phase of thickening via reactivation of preexisting internal structures. In contrast, we suspect that the northern wedge is undergoing an accretion or widening phase primarily via slip on relatively young thrust-front faults.
Petrov, Pavel S; Sturm, Frédéric
2016-03-01
A problem of sound propagation in a shallow-water waveguide with a weakly sloping penetrable bottom is considered. The adiabatic mode parabolic equations are used to approximate the solution of the three-dimensional (3D) Helmholtz equation by modal decomposition of the acoustic pressure field. The mode amplitudes satisfy parabolic equations that admit analytical solutions in the special case of the 3D wedge. Using the analytical formula for modal amplitudes, an explicit and remarkably simple expression for the acoustic pressure in the wedge is obtained. The proposed solution is validated by the comparison with a solution of the 3D penetrable wedge problem obtained using a fully 3D parabolic equation that includes a leading-order cross term correction.
Wide acceptance angle, high concentration ratio, optical collector
NASA Technical Reports Server (NTRS)
Kruer, Mark A. (Inventor)
1991-01-01
A cassegrain optical system provides improved collection of off-axis light yet is still characterized by a high concentration ratio. The optical system includes a primary mirror for collecting incoming light and reflecting the light to a secondary mirror which, in turn, reflects the light to a solar cell or other radiation collection device. The primary mirror reflects incoming on-axis light onto an annular section of the secondary mirror and results in the reflection of a substantial amount of incoming off-axis light onto the remainder of the secondary mirror. Thus light which would otherwise be lost to the system will be captured by the collector. Furthermore, the off-axis sections of the secondary mirror may be of a different geometrical shape than the on-axis annular section so as to optimize the amount of off-axis light collected.
Effects of off-axis loading on the tensile behavior of a ceramic-matrix composite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lynch, C.S.; Evans, A.G.
A 0{degree}/90{degree} ceramic-matrix composite (CMC) comprised of Nicalon fibers in magnesium aluminosilicate (MAS) has been loaded in tension in three orientations relative to the fiber direction: 0, 30, and 45{degree}. The off-axis loaded samples exhibit inelastic deformation at appreciably lower stresses than samples loads at 0{degree}. Matrix cracking governs the inelastic strains in all orientations. But, important differences in the morphologies and sequencing of the cracks account for the differences in the stress levels. Off-axis failure also occurs at substantially lower stresses than on-axis failure. On-axis composite failure is governed by fiber fracture, but off-axis failure involves matrix-crack coalescence. Tomore » facilitate interpretation and modeling of these behaviors, the interface friction and debond stresses have been determined from hysteresis measurements.« less
Seafloor Spreading in the Lau-Havre Backarc Basins: From Fast to Ultra Slow
NASA Astrophysics Data System (ADS)
Martinez, F.; Dunn, R. A.; Sleeper, J. D.
2013-12-01
Seafloor spreading in the Lau Basin occurs along the well-organized Eastern Lau Spreading Center (ELSC) and Valu Fa Ridges (VFR) opening at 97-39 mm/yr. The ELSC/VFR produce two distinct crustal types sub-parallel to the ridge as a function of their separation from the arc volcanic front. Arc-proximal spreading forms a shallow, thick crust with arc-like lavas that abruptly changes to a deeper, thinner crust with backarc basin basalt (BABB)-like lavas as the ridges separate from the arc volcanic front. Southward in the Havre Trough opening rates decrease to 15 mm/yr and a well-organized spreading axis is largely absent. Instead, active volcanism appears to be distributed across a broad zone located asymmetrically near the arc side of the basin. Further, crustal accretion appears to have two distinct styles forming a shallower terrain floored by arc-like lavas and deeper rifted basins floored by more BABB-like lavas [Wysoczanski et al., 2010, G-cubed]. Although these crustal terrains broadly resemble those flanking the ELSC/VFR, in the Havre Trough they are organized into bands that trend across the basin with the shallower arc-like terrains typically trailing from Kermadec arc front volcanoes. We hypothesize that the variation in style of crustal accretion along the Lau-Havre backarc system is controlled by the southward decreasing rate of plate extension superimposed on a compositionally variable mantle wedge. Distinct hydrous and less-hydrous mantle domains have been proposed for the mantle wedge [Martinez & Taylor, 2002; Dunn & Martinez, 2011; Nature]. Within the hydrous domain (< about 50 km from the arc volcanic front) further compositional 'fingers' trailing basinward from arc front volcanoes have been interpreted in the Lau Basin based on ridge axis morphology and chemistry [Sleeper & Martinez, submitted]. In the Lau Basin, intermediate to fast spreading rates impose a 2D plate-driven advective regime in the mantle wedge constraining volcanic accretion to the 2D narrow ridge axis. Effects of the cross trending compositional 'fingers' are minimized and only expressed as second-order geological and geochemical features at the ridge. As opening rates decrease to ultra-slow in the Havre Trough, 2D plate-driven components of mantle advection and melting are minimized. The inherent buoyancy of melts dominate advection and volcanic emplacement allowing a clearer expression of intrinsic 3D compositional and melt generation patterns in the mantle wedge. These observations suggest that mantle wedge structure fundamentally consists of arc-like mantle source compositional fingers trailing basinward from arc front volcanoes within a hydrous but more MORB source-like mantle. Spreading rate controls the degree of expression of these compositional fingers in back-arc volcanic crustal accretion. Fast to intermediate rate spreading imposes a 2D ridge-parallel distribution to crustal domains whereas slow to ultra slow spreading rates allow 3D mantle wedge compositional and melt generation patterns to be expressed.
NASA Astrophysics Data System (ADS)
Gao, J.; Wu, S.; Yao, Y.; Chen, C.
2017-12-01
The South China Sea (SCS) which located at the southeast edge of the Eurasian plate, is heavily influenced by the Philippine Sea plate and the Indo-Australian plate. As eastern boundary of the SCS, Manila subduction zone was created by the northwestern movement of the Philippine Sea plate, recorded the key information on formation and evolution of the SCS and often triggered off earthquakes and tsunami in the East and South Asia. Using high resolution multi-channel seismic data across the northern Manila subduction zone, this study analyzed sedimentary characteristics of oceanic basin and trench, and fine described features of structural deformation and architecture of accretionary wedge and magmatism to discuss the time of subduction inception, thrust motion and influence of seamount subduction on the geometry of the Manila trench. Results show that lower slope of accretionary wedge mainly consist of imbricated thrusts with blind thrust as the frontal fault and structural wedge whereas upper slope was obscure for intensely structural deformation and magmatism. All the thrust faults merged into a detachment fault/surface which may root in Lower Miocene or even older strata, cut off the Miocene near buried seamount and extended the Pliocene upward, suggesting that this detachment fault was obviously influenced by buried seamount and basement high below the accretionary wedge. Magmatism began to be active from late Miocene and continued to be intense during Pliocene and Quaternary in the oceanic basin, trench and accretionary wedge. Based on characteristics of sedimentary and structural deformation, this study proposed that accretionary wedge of the northern Manila subduction zone formed before 16.5 Ma and propagated to the SCS through piggyback propagation thrusting when seafloor spreading of the SCS was still ongoing before 15 Ma. Subduction of extended continental crust in the northeastern SCS created a significantly concaving eastward to geometric shape of the northern Manila trench. With the subducting of fossil ridge of the SCS to the Manila trench and ridge/trench collision happening in the future, the convexly westward arc feature of Manila trench was changed to flat and will be even concave eastward.
NASA Astrophysics Data System (ADS)
Gao, Lingyu; Li, Xinghua; Guo, Qianrui; Quan, Jing; Hu, Zhengyue; Su, Zhikun; Zhang, Dong; Liu, Peilu; Li, Haopeng
2018-01-01
The internal structure of off-axis three-mirror system is commonly complex. The mirror installation error in assembly always affects the imaging line-of-sight and further degrades the image quality. Due to the complexity of the optical path in off-axis three-mirror optical system, the straightforward theoretical analysis on the variations of imaging line-of-sight is extremely difficult. In order to simplify the theoretical analysis, an equivalent single-mirror system is proposed and presented in this paper. In addition, the mathematical model of single-mirror system is established and the accurate expressions of imaging coordinate are derived. Utilizing the simulation software ZEMAX, off-axis three-mirror model and single-mirror model are both established. By adjusting the position of mirror and simulating the line-of-sight rotation of optical system, the variations of imaging coordinates are clearly observed. The final simulation results include: in off-axis three-mirror system, the varying sensitivity of the imaging coordinate to the rotation of line-of-sight is approximately 30 um/″; in single-mirror system, the varying sensitivity of the imaging coordinate to the rotation of line-of-sight is 31.5 um/″. Compared to the simulation results of the off-axis three-mirror model, the 5% relative error of single-mirror model analysis highly satisfies the requirement of equivalent analysis and also verifies its validity. This paper presents a new method to analyze the installation error of the mirror in the off-axis three-mirror system influencing on the imaging line-of-sight. Moreover, the off-axis three-mirror model is totally equivalent to the single-mirror model in theoretical analysis.
An automated optical wedge calibrator for Dobson ozone spectrophotometers
NASA Technical Reports Server (NTRS)
Evans, R. D.; Komhyr, W. D.; Grass, R. D.
1994-01-01
The Dobson ozone spectrophotometer measures the difference of intensity between selected wavelengths in the ultraviolet. The method uses an optical attenuator (the 'Wedge') in this measurement. The knowledge of the relationship of the wedge position to the attenuation is critical to the correct calculation of ozone from the measurement. The procedure to determine this relationship is time-consuming, and requires a highly skilled person to perform it correctly. The relationship has been found to change with time. For reliable ozone values, the procedure should be done on a Dobson instrument at regular intervals. Due to the skill and time necessary to perform this procedure, many instruments have gone as long as 15 years between procedures. This article describes an apparatus that performs the procedure under computer control, and is adaptable to the majority of existing Dobson instruments. Part of the apparatus is usable for normal operation of the Dobson instrument, and would allow computer collection of the data and real-time ozone measurements.
Reconstruction of Bulk Operators within the Entanglement Wedge in Gauge-Gravity Duality
NASA Astrophysics Data System (ADS)
Dong, Xi; Harlow, Daniel; Wall, Aron C.
2016-07-01
In this Letter we prove a simple theorem in quantum information theory, which implies that bulk operators in the anti-de Sitter/conformal field theory (AdS/CFT) correspondence can be reconstructed as CFT operators in a spatial subregion A , provided that they lie in its entanglement wedge. This is an improvement on existing reconstruction methods, which have at most succeeded in the smaller causal wedge. The proof is a combination of the recent work of Jafferis, Lewkowycz, Maldacena, and Suh on the quantum relative entropy of a CFT subregion with earlier ideas interpreting the correspondence as a quantum error correcting code.
Reconstruction of Bulk Operators within the Entanglement Wedge in Gauge-Gravity Duality.
Dong, Xi; Harlow, Daniel; Wall, Aron C
2016-07-08
In this Letter we prove a simple theorem in quantum information theory, which implies that bulk operators in the anti-de Sitter/conformal field theory (AdS/CFT) correspondence can be reconstructed as CFT operators in a spatial subregion A, provided that they lie in its entanglement wedge. This is an improvement on existing reconstruction methods, which have at most succeeded in the smaller causal wedge. The proof is a combination of the recent work of Jafferis, Lewkowycz, Maldacena, and Suh on the quantum relative entropy of a CFT subregion with earlier ideas interpreting the correspondence as a quantum error correcting code.
Zhang, Dongdong; Huang, Yaxin; Zhao, Qilin; Li, Fei; Gao, Yifeng
2014-01-01
A novel hybrid FRP-aluminum truss system has been employed in a two-rut modular bridge superstructure composed of twin inverted triangular trusses. The actual flexural behavior of a one-rut truss has been previously investigated under the on-axis loading test; however, the structural performance of the one-rut truss subjected to an off-axis load is still not fully understood. In this paper, a geometrical linear finite element model is introduced and validated by the on-axis loading test; the structural performance of the one-rut truss subjected to off-axis load was numerically obtained; the dissimilarities of the structural performance between the two different loading cases are investigated in detail. The results indicated that (1) the structural behavior of the off-axis load differs from that of the on-axis load, and the off-axis load is the critical loading condition controlling the structural performance of the triangular truss; (2) under the off-axis load, the FRP trussed members and connectors bear certain out-of-plane bending moments and are subjected to a complicated stress state; and (3) the stress state of these members does not match that of the initial design, and optimization for the redesign of these members is needed, especially for the pretightened teeth connectors. PMID:25254254
Content-based fused off-axis object illumination direct-to-digital holography
Price, Jeffery R.
2006-05-02
Systems and methods are described for content-based fused off-axis illumination direct-to-digital holography. A method includes calculating an illumination angle with respect to an optical axis defined by a focusing lens as a function of data representing a Fourier analyzed spatially heterodyne hologram; reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object the object beam incident upon the object at the illumination angle; focusing the reference beam and the object beam at a focal plane of a digital recorder to from the content-based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording the content based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
U-Pb Data On Apatites With Common Lead Correction : Exemples From The Scottish Caledonides
NASA Astrophysics Data System (ADS)
Jewison, E.; Deloule, E.; Villeneuve, J.; Bellahsen, N.; Labrousse, L.; Rosenberg, C.; Pik, R.; Chew, D.
2017-12-01
Apatite is a widely used mineral in low-temperature thermochronology (U-Th/He and AFT). The use of apatite in U-Pb geochronology has a great potential, given its closure temperature around 450°C, for orogen thermostructural evolution studies. However, since apatite can accumulate significant amount of initial Pb in its structure, its use can be hindered by the lack of 204 Pb estimations. To work around this, two options are commonly used : either use a ploting sytem that does not require corrected ratios, or use a proxy to estimate 204Pb and use it to correct the ratios. In this study we use a SIMS to mesure 204Pb in order to compare Tera-Wasserburg diagram and corrected ages to examine the cooling pattern in the northern Highlands of Scotland. The Highlands is an extensively studied caledonian collision wedge which results from the closure of the Iapétus Ocean during the Orodivician-Silurian. Two orogenic events are related to this closing, the grampian event (480-460Ma) and the scandian event (435-415 Ma) that culminated in the stacking of major ductile thrusts. The thermal history of thoses nappes are hence complex and the cooling pattern poorly constrained. Corrected apatite U-Pb ages provide new constrains on ductile wedge building and improve our understanding of mid to lower-crustal deformation and orogenic exhumation. Thoses corrected ages yield equivalent errors and mean ages from the classic method. Those data suggest a global cooling younger than previously thought and a sequence departing from a simple forward sequence. We thus present a refined thermal evolution and conceptualize a model of ductile wedge evolution.
NASA Astrophysics Data System (ADS)
Zhang, Lei; Li, Dong; Liu, Yu; Liu, Jingxiao; Li, Jingsong; Yu, Benli
2017-11-01
We demonstrate the validity of the simultaneous reverse optimization reconstruction (SROR) algorithm in circular subaperture stitching interferometry (CSSI), which is previously proposed for non-null aspheric annular subaperture stitching interferometry (ASSI). The merits of the modified SROR algorithm in CSSI, such as auto retrace error correction, no need of overlap and even permission of missed coverage, are analyzed in detail in simulations and experiments. Meanwhile, a practical CSSI system is proposed for this demonstration. An optical wedge is employed to deflect the incident beam for subaperture scanning by its rotation and shift instead of the six-axis motion-control system. Also the reference path can provide variable Zernike defocus for each subaperture test, which would decrease the fringe density. Experiments validating the SROR algorithm in this CSSI is implemented with cross validation by testing of paraboloidal mirror, flat mirror and astigmatism mirror. It is an indispensable supplement in SROR application in general subaperture stitching interferometry.
Two surgical approaches to fracture malunion repair.
Rahal, Sheila C; Teixeira, Carlos R; Pereira-Júnior, Oduvaldo C M; Vulcano, Luiz C; Aguiar, Antonio J A; Rassy, Fabrício B
2008-12-01
Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-wedge corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was an adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through a bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.
What happens to full-f gyrokinetic transport and turbulence in a toroidal wedge simulation?
Kim, Kyuho; Chang, C. S.; Seo, Janghoon; ...
2017-01-24
Here, in order to save the computing time or to fit the simulation size into a limited computing hardware in a gyrokinetic turbulence simulation of a tokamak plasma, a toroidal wedge simulation may be utilized in which only a partial toroidal section is modeled with a periodic boundary condition in the toroidal direction. The most severe restriction in the wedge simulation is expected to be in the longest wavelength turbulence, i.e., ion temperature gradient (ITG) driven turbulence. The global full-f gyrokinetic code XGC1 is used to compare the transport and turbulence properties from a toroidal wedge simulation against the fullmore » torus simulation in an ITG unstable plasma in a model toroidal geometry. It is found that (1) the convergence study in the wedge number needs to be conducted all the way down to the full torus in order to avoid a false convergence, (2) a reasonably accurate simulation can be performed if the correct wedge number N can be identified, (3) the validity of a wedge simulation may be checked by performing a wave-number spectral analysis of the turbulence amplitude |δΦ| and assuring that the variation of δΦ between the discrete kθ values is less than 25% compared to the peak |δΦ|, and (4) a frequency spectrum may not be used for the validity check of a wedge simulation.« less
What happens to full-f gyrokinetic transport and turbulence in a toroidal wedge simulation?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Kyuho; Chang, C. S.; Seo, Janghoon
Here, in order to save the computing time or to fit the simulation size into a limited computing hardware in a gyrokinetic turbulence simulation of a tokamak plasma, a toroidal wedge simulation may be utilized in which only a partial toroidal section is modeled with a periodic boundary condition in the toroidal direction. The most severe restriction in the wedge simulation is expected to be in the longest wavelength turbulence, i.e., ion temperature gradient (ITG) driven turbulence. The global full-f gyrokinetic code XGC1 is used to compare the transport and turbulence properties from a toroidal wedge simulation against the fullmore » torus simulation in an ITG unstable plasma in a model toroidal geometry. It is found that (1) the convergence study in the wedge number needs to be conducted all the way down to the full torus in order to avoid a false convergence, (2) a reasonably accurate simulation can be performed if the correct wedge number N can be identified, (3) the validity of a wedge simulation may be checked by performing a wave-number spectral analysis of the turbulence amplitude |δΦ| and assuring that the variation of δΦ between the discrete kθ values is less than 25% compared to the peak |δΦ|, and (4) a frequency spectrum may not be used for the validity check of a wedge simulation.« less
A compact and lightweight off-axis lightguide prism in near to eye display
NASA Astrophysics Data System (ADS)
Zhuang, Zhenfeng; Cheng, Qijia; Surman, Phil; Zheng, Yuanjin; Sun, Xiao Wei
2017-06-01
We propose a method to improve the design of an off-axis lightguide configuration for near to eye displays (NED) using freeform optics technology. The advantage of this modified optical system, which includes an organic light-emitting diode (OLED), a doublet lens, an imaging lightguide prism and a compensation prism, is that it increases optical length path, offers a smaller size, as well as avoids the obstructed views, and matches the user's head shape. In this system, the light emitted from the OLED passes through the doublet lens and is refracted/reflected by the imaging lightguide prism, which is used to magnify the image from the microdisplay, while the compensation prism is utilized to correct the light ray shift so that a low-distortion image can be observed in a real-world setting. A NED with a 4 mm diameter exit pupil, 21.5° diagonal full field of view (FoV), 23 mm eye relief, and a size of 33 mm by 9.3 mm by 16 mm is designed. The developed system is compact, lightweight and suitable for entertainment and education application.
Liu, Changgeng; Thapa, Damber; Yao, Xincheng
2017-01-01
Guidestar hologram based digital adaptive optics (DAO) is one recently emerging active imaging modality. It records each complex distorted line field reflected or scattered from the sample by an off-axis digital hologram, measures the optical aberration from a separate off-axis digital guidestar hologram, and removes the optical aberration from the distorted line fields by numerical processing. In previously demonstrated DAO systems, the optical aberration was directly retrieved from the guidestar hologram by taking its Fourier transform and extracting the phase term. For the direct retrieval method (DRM), when the sample is not coincident with the guidestar focal plane, the accuracy of the optical aberration retrieved by DRM undergoes a fast decay, leading to quality deterioration of corrected images. To tackle this problem, we explore here an image metrics-based iterative method (MIM) to retrieve the optical aberration from the guidestar hologram. Using an aberrated objective lens and scattering samples, we demonstrate that MIM can improve the accuracy of the retrieved aberrations from both focused and defocused guidestar holograms, compared to DRM, to improve the robustness of the DAO. PMID:28380937
Dosimetric Characteristics of Wedged Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sidhu, N.P.S.; Breitman, Karen
2015-01-15
The beam characteristics of the wedged fields in the nonwedged planes (planes normal to the wedged planes) were studied for 6 MV and 15 MV x-ray beams. A method was proposed for determining the maximum field length of a wedged field that can be used in the nonwedged plane without introducing undesirable alterations in the dose distributions of these fields. The method requires very few measurements. The relative wedge factors of 6 MV and 15 MV X-rays were determined for wedge filters of nominal wedge angles of 15°, 30°, 45°, and 60° as a function of depth and field size.more » For a 6 MV beam the relative wedge factors determined for a field size of 10 × 10 cm{sup 2} for 30°, 45°, and 60° wedge filters can be used for various field sizes ranging from 4 cm{sup 2} to 20 cm{sup 2} (except for the 60° wedge for which the maximum field size that can be used is 15 × 20 cm{sup 2}) without introducing errors in the dosimetric calculations of more than 0.5% for depths up to 20 cm and 1% for depths up to 30 cm. For the 15° wedge filter the relative wedge factor for a field size of 10 × 10 cm{sup 2} can be used over the same range of field sizes by introducing slightly higher error, 0.5% for depths up to 10 cm and 1% for depths up to 30 cm. For a 15 MV beam the maximum magnitude of the relative wedge factors for 45° and 60° lead wedges is of the order of 1%, and it is not important clinically to apply a correction of that magnitude. For a 15 MV beam the relative wedge factors determined for a field size of 6 × 6 cm{sup 2} for the 15° and 30° steel wedges can be used over a range of field sizes from 4 cm{sup 2} to 20 cm{sup 2} without causing dosimetric errors greater than 0.5% for depths up to 10 cm.« less
New possibilities for tuning ultrathin cobalt film magnetic properties by a noble metal overlayer.
Kisielewski, M; Maziewski, A; Tekielak, M; Wawro, A; Baczewski, L T
2002-08-19
Complementary multiscale magneto-optical studies based on the polar Kerr effect are carried out on an ultrathin cobalt wedge covered with a silver wedge and subsequently with the Au thick layer. A few monolayers of Ag are found to have a substantial effect on magnetic anisotropy, the coercivity field, and Kerr rotation. The silver overlayer thickness-driven magnetic reorientation from easy axis to easy plane generates a new type of 90 degrees magnetic wall for cobalt thicknesses between 1.3 and 1.8 nm. The tuning of the wall width in a wide range is possible. Tailoring of the overlayer structure can be used for ultrathin film magnetic patterning.
Malaligned dynamic anterior cervical plate: a biomechanical analysis of effectiveness.
Lawrence, Brandon D; Patel, Alpesh A; Guss, Andrew; Ryan Spiker, W; Brodke, Darrel S
2014-12-01
Biomechanical evaluation. To evaluate the kinematic and load-sharing differences of dynamic anterior cervical plates when placed in-line at 0° and off-axis at 20°. The use of dynamic anterior cervical plating systems has recently gained popularity due to the theoretical benefit of improved load sharing with graft subsidence. Occasionally, due to anatomical restraints, the anterior cervical plate may be placed off-axis in the coronal plane. This may potentially decrease the dynamization capability of the plate, leading to less load sharing and potentially decreased fusion rates. The purpose of this study was to comprehensively evaluate the kinematic and load-sharing differences of a dynamic plate placed in-line versus off-axis in the coronal plane. Thirteen fresh-frozen human cadaveric cervical spines (C2-T1) were used. Nondestructive range-of-motion testing was performed with a pneumatically controlled spine simulator in flexion/extension, lateral bending, and axial rotation using the OptoTrak motion measurement system. A C5 corpectomy was performed, and a custom interbody spacer with an integrated load cell collected load-sharing data under axial compression at varying loads. A dynamic anterior cervical plate was placed in-line at 0° and then off-axis at 20°. Testing conditions ensued using a full-length spacer, followed by simulated subsidence by removing 10% of the height of the original spacer. There were no kinematic differences noted in the in-line model versus the off-axis model. After simulated subsidence, the small decreases in stiffness and increases in motion were similar whether the plate was placed in-line or off-axis in all 3 planes of motion. There were also no significant differences in the load-sharing characteristics of the in-line plate versus the off-axis plate in either the full-length model or the subsided interbody model. This study suggests that off-axis dynamic plate positioning does not significantly impact construct kinematics or graft load sharing. As such, we do not recommend removal or repositioning of an off-axis placed dynamic plate because the kinematic and load-sharing biomechanical properties are similar. N/A.
Mauldin, F William; Owen, Kevin; Tiouririne, Mohamed; Hossack, John A
2012-06-01
The portability, low cost, and non-ionizing radiation associated with medical ultrasound suggest that it has potential as a superior alternative to X-ray for bone imaging. However, when conventional ultrasound imaging systems are used for bone imaging, clinical acceptance is frequently limited by artifacts derived from reflections occurring away from the main axis of the acoustic beam. In this paper, the physical source of off-axis artifacts and the effect of transducer geometry on these artifacts are investigated in simulation and experimental studies. In agreement with diffraction theory, the sampled linear-array geometry possessed increased off-axis energy compared with single-element piston geometry, and therefore, exhibited greater levels of artifact signal. Simulation and experimental results demonstrated that the linear-array geometry exhibited increased artifact signal when the center frequency increased, when energy off-axis to the main acoustic beam (i.e., grating lobes) was perpendicularly incident upon off-axis surfaces, and when off-axis surfaces were specular rather than diffusive. The simulation model used to simulate specular reflections was validated experimentally and a correlation coefficient of 0.97 between experimental and simulated peak reflection contrast was observed. In ex vivo experiments, the piston geometry yielded 4 and 6.2 dB average contrast improvement compared with the linear array when imaging the spinous process and interlaminar space of an animal spine, respectively. This work indicates that off-axis reflections are a major source of ultrasound image artifacts, particularly in environments comprising specular reflecting (i.e., bone or bone-like) objects. Transducer geometries with reduced sensitivity to off-axis surface reflections, such as a piston transducer geometry, yield significant reductions in image artifact.
Arnold, Heino
2008-12-01
Realignment of the great toe in the case of a hallux valgus interphalangeus by means of a medially based closing wedge osteotomy. Hallux valgus interphalangeus deformity, characterized by an enlarged distal articular surface angle (> 10 degrees). Correction of a hallux valgus interphalangeus deformity as an additional procedure in the case of hallux valgus surgery. Incongruent first metatarsophalangeal joint with lateral subluxation of the proximal phalanx. Isolated procedure to correct hallux valgus deformity. Lack of patient compliance. Neurovascular disturbance of the forefoot. Medially based closing wedge osteotomy of the proximal phalanx to reduce the distal articular surface angle. Fixation with a lag screw, cannulated Herbert screw, memory cramp, threaded Kirschner wire, or interosseous suture. Wound dressing to assure the position of the great toe. Radiographic documentation of the forefoot in two planes. Strict elevation of the operated foot to prevent postoperative swelling. Mobilization of the patient with a forefoot relief orthosis, until consolidation of the osteotomy is verified radiologically (4-5 weeks). Low-molecular-weight heparin for at least 1 week. Hallux valgus bandage or functional taping for 6 weeks postoperatively in patients with additional metatarsal osteotomy. Clinical and radiologic follow-up based on 32 patients showed good results. The postoperative Hallux Score of the American Orthopaedic Foot and Ankle Society improved to 89 points.
Sawicki, Richard H.; Sweatt, William
1987-01-01
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique utilizes first means which defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and second means acting on the first means for adjustably bending the light reflecting surface into a particular selected one of the different curvatures depending upon the astigmatism to be corrected for and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment to the reinforced side edges of the light reflecting surface.
Adaptive compensation of aberrations in ultrafast 3D microscopy using a deformable mirror
NASA Astrophysics Data System (ADS)
Sherman, Leah R.; Albert, O.; Schmidt, Christoph F.; Vdovin, Gleb V.; Mourou, Gerard A.; Norris, Theodore B.
2000-05-01
3D imaging using a multiphoton scanning confocal microscope is ultimately limited by aberrations of the system. We describe a system to adaptively compensate the aberrations with a deformable mirror. We have increased the transverse scanning range of the microscope by three with compensation of off-axis aberrations.We have also significantly increased the longitudinal scanning depth with compensation of spherical aberrations from the penetration into the sample. Our correction is based on a genetic algorithm that uses second harmonic or two-photon fluorescence signal excited by femtosecond pulses from the sample as the enhancement parameter. This allows us to globally optimize the wavefront without a wavefront measurement. To improve the speed of the optimization we use Zernike polynomials as the basis for correction. Corrections can be stored in a database for look-up with future samples.
Photographic simulation of off-axis blurring due to chromatic aberration in spectacle lenses.
Doroslovački, Pavle; Guyton, David L
2015-02-01
Spectacle lens materials of high refractive index (nd) tend to have high chromatic dispersion (low Abbé number [V]), which may contribute to visual blurring with oblique viewing. A patient who noted off-axis blurring with new high-refractive-index spectacle lenses prompted us to do a photographic simulation of the off-axis aberrations in 3 readily available spectacle lens materials, CR-39 (nd = 1.50), polyurethane (nd = 1.60), and polycarbonate (nd = 1.59). Both chromatic and monochromatic aberrations were found to cause off-axis image degradation. Chromatic aberration was more prominent in the higher-index materials (especially polycarbonate), whereas the lower-index CR-39 had more astigmatism of oblique incidence. It is important to consider off-axis aberrations when a patient complains of otherwise unexplained blurred vision with a new pair of spectacle lenses, especially given the increasing promotion of high-refractive-index materials with high chromatic dispersion. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Expected neutrino fluence from short Gamma-Ray Burst 170817A and off-axis angle constraints
NASA Astrophysics Data System (ADS)
Biehl, D.; Heinze, J.; Winter, W.
2018-05-01
We compute the expected neutrino fluence from SGRB 170817A, associated with the gravitational wave event GW 170817, directly based on Fermi observations in two scenarios: structured jet and off-axis (observed) top-hat jet. While the expected neutrino fluence for the structured jet case is very small, large off-axis angles imply high radiation densities in the jet, which can enhance the neutrino production efficiency. In the most optimistic allowed scenario, the neutrino fluence can reach only 10-4 of the sensitivity of the neutrino telescopes. We furthermore demonstrate that the fact that gamma-rays can escape limits the baryonic loading (energy in protons versus photons) and the off-axis angle for the internal shock scenario. In particular, for a baryonic loading of 10, the off-axis angle is more strongly constrained by the baryonic loading than by the time delay between the gravitational wave event and the onset of the gamma-ray emission.
SU-E-T-01: 2-D Characterization of DLG Among All MLC Leaf Pairs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumaraswamy, L; Xu, Z; Podgorsak, M
Purpose: The aim of this study is to evaluate the variation of dosimetric leaf-gap (DLG) along the travel path of each MLC leaf pair. This study evaluates whether the spatial variations in DLG could cause dose differences between TPS-calculated and measured dose. Methods: The 6MV DLG values were measured for all leaf pairs in the direction of leaf motion using a 2-D diode array and 0.6cc ion chamber. These measurements were performed on two Varian Linacs, employing the Millennium 120-leaf MLC and a 2-D-DLG variation map was created via in-house software. Several test plans were created with sweeping MLC fieldsmore » using constant gaps from 2mm to 10mm and corrected for 2-D variation utilizing in-house software. Measurements were performed utilizing the MapCHECK at 5.0cm depth for plans with and without the 2-D DLG correction and compared to the TPS calculated dose via gamma analysis (3%/3mm). Results: The measured DLGs for the middle 40 MLC leaf pairs (0.5cm width) were very similar along the central superior-inferior axis, with maximum variation of 0.2mm. The outer 20 MLC leaf pairs (1.0cm width) have DLG values from 0.32mm (mean) to 0.65mm (maximum) lower than the central leaf-pair, depending on off-axis distance. Gamma pass rates for the 2mm, 4mm, and 6mm sweep plans increased by 23.2%, 28.7%, and 26.0% respectively using the 2-D-DLG correction. The most improved dose points occur in areas modulated by the 1.0cm leaf-pairs. The gamma pass rate for the 10mm sweep plan increased by only 7.7%, indicating that the 2D variation becomes less significant for dynamic plans with larger MLC gaps. Conclusion: Fluences residing significantly off-axis with narrow sweeping gaps may exhibit significant variations from planned dose due to large differences between the true DLG exhibited by the 1.0cm leaf-pairs versus the constant DLG value utilized by the TPS for dose calculation.« less
Jo, Dae-Jean; Kim, Yong-Sang; Kim, Sung-Min; Kim, Ki-Tack; Seo, Eun-Min
2015-10-01
Most thoracolumbar fractures have a good healing outcome with adequate treatment. However, posttraumatic thoracolumbar kyphosis can occur in a proportion of thoracolumbar fractures after inappropriate treatment, osteoporosis, or osteonecrosis of the vertebral body. There are several surgical options to correct posttraumatic thoracolumbar kyphosis, including anterior, posterior, and combined approaches, which are associated with varying degrees of success. The aim of this study was to assess the use of a modified closing wedge osteotomy for the treatment of posttraumatic thoracolumbar kyphosis and to evaluate the radiographic findings and clinical outcomes of patients treated using this technique. Thirteen consecutive patients with symptomatic posttraumatic thoracolumbar kyphosis were treated using a modified closing wedge osteotomy. The mean patient age was 62 years. The kyphosis apex ranged from T-10 to L-2. The sagittal alignment, kyphotic angle, neurological function, visual analog scale for back pain, and Oswestry Disability Index were evaluated before surgery and at follow-up. RESULTS The mean preoperative regional angle was 27.4°, and the mean correction angle was 29.6°. Sagittal alignment improved with a mean correction rate of 58.3%. The mean surgical time was 275 minutes, and the mean intraoperative blood loss was 1585 ml. The intraoperative complications included 2 dural tears, 1 nerve root injury, and 1 superficial wound infection. The mean visual analog scale score for back pain improved from 6. 6 to 2, and the Oswestry Disability Index score decreased from 55.4 to 22.6 at the last follow-up. All patients achieved bony anterior fusion based on the presence of trabecular bone bridging at the osteotomy site. The modified posterior closing wedge osteotomy technique achieves satisfactory kyphosis correction with direct visualization of the circumferentially decompressed spinal cord, as well as good fusion with less blood loss and fewer complications. It is an alternative method for treating patients with posttraumatic thoracolumbar kyphosis.
Open wedge high tibial osteotomies: Calcium-phosphate ceramic spacer versus autologous bonegraft.
Gouin, F; Yaouanc, F; Waast, D; Melchior, B; Delecrin, J; Passuti, N
2010-10-01
Valgus tibial osteotomy (VTO) is a well-known procedure for the treatment of medial compartment femoro-tibial osteoarthritis. Good and very good results have been reported with calcium phosphate wedges, which avoid the inconveniences of autologous grafts use. The hypothesis of this study is that with equivalent results in the treatment of osteoarthritis of the knee, the use of calcium phosphate wedges (BMCaPh) to fill the bone defect created by osteotomy would result in fewer specific complications and less pain associated with autologous grafts (AUTO) harvesting. This prospective, controlled, randomised study included one arm that received a macroporous, biphasic calcium phosphate wedge (BMCaPh group) and one arm that received an autologous tricortical graft (AUTO group) for filling. The same plate with locked screws was used for fixation in all cases. All patients underwent at least two years of clinical and radiographic post-operative follow-up. Forty patients were included. Loss of correction occurred in six of the twenty-two patients in the BMCaPh group (27%), resulting in three early surgical revisions, compared to one loss of correction in the AUTO group. Lateral cortical hinge tears were a risk factor for loss of correction for the entire cohort and in the BMCaPh group. (relative risk 13.3 [1.9-92]. Moreover, union took significantly longer and pain lasted significantly longer in the BMCaPh group, although results were comparable at 6 months. A significant number of undesirable events (loss of correction) occurred in this study, limiting the number of included patients. Nevertheless, the results show that although there was no difference in the two groups for overall complications, number of revisions all causes combined, or clinical results, filling with BMCaPh was less tolerated and increased the risk of loss of correction when local mechanical conditions of the knee were unfavourable (lateral cortical hinge tears). Moreover, although it is not possible to draw a conclusion because of methodology bias in this study, early weight-bearing resumption on the knee also seemed to favour these complications. Level II. Prospective randomized study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.
Kroutilķková, Daniela; Novotný, Josef; Judas, Libor
2003-02-01
The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xue Qingsheng
A low-cost, broadband, astigmatism-corrected Czerny-Turner arrangement with a fixed plane grating is proposed. A wedge cylindrical lens is used to correct astigmatism over a broadband spectral range. The principle and method of astigmatism correction are described in detail. We compare the performance of this modified Czerny-Turner arrangement with that of the traditional Czerny-Turner arrangement by using a practical Czerny-Turner imaging spectrometer example.
Hybrid shallow on-axis and deep off-axis hydrothermal circulation at fast-spreading ridges.
Hasenclever, Jörg; Theissen-Krah, Sonja; Rüpke, Lars H; Morgan, Jason P; Iyer, Karthik; Petersen, Sven; Devey, Colin W
2014-04-24
Hydrothermal flow at oceanic spreading centres accounts for about ten per cent of all heat flux in the oceans and controls the thermal structure of young oceanic plates. It also influences ocean and crustal chemistry, provides a basis for chemosynthetic ecosystems, and has formed massive sulphide ore deposits throughout Earth's history. Despite this, how and under what conditions heat is extracted, in particular from the lower crust, remains largely unclear. Here we present high-resolution, whole-crust, two- and three-dimensional simulations of hydrothermal flow beneath fast-spreading ridges that predict the existence of two interacting flow components, controlled by different physical mechanisms, that merge above the melt lens to feed ridge-centred vent sites. Shallow on-axis flow structures develop owing to the thermodynamic properties of water, whereas deeper off-axis flow is strongly shaped by crustal permeability, particularly the brittle-ductile transition. About 60 per cent of the discharging fluid mass is replenished on-axis by warm (up to 300 degrees Celsius) recharge flow surrounding the hot thermal plumes, and the remaining 40 per cent or so occurs as colder and broader recharge up to several kilometres away from the axis that feeds hot (500-700 degrees Celsius) deep-rooted off-axis flow towards the ridge. Despite its lower contribution to the total mass flux, this deep off-axis flow carries about 70 per cent of the thermal energy released at the ridge axis. This combination of two flow components explains the seismically determined thermal structure of the crust and reconciles previously incompatible models favouring either shallower on-axis or deeper off-axis hydrothermal circulation.
Spatial variability of E. coli in an urban salt-wedge estuary.
Jovanovic, Dusan; Coleman, Rhys; Deletic, Ana; McCarthy, David
2017-01-15
This study investigated the spatial variability of a common faecal indicator organism, Escherichia coli, in an urban salt-wedge estuary in Melbourne, Australia. Data were collected through comprehensive depth profiling in the water column at four sites and included measurements of temperature, salinity, pH, dissolved oxygen, turbidity, and E. coli concentrations. Vertical variability of E. coli was closely related to the salt-wedge dynamics; in the presence of a salt-wedge, there was a significant decrease in E. coli concentrations with depth. Transverse variability was low and was most likely dwarfed by the analytical uncertainties of E. coli measurements. Longitudinal variability was also low, potentially reflecting minimal die-off, settling, and additional inputs entering along the estuary. These results were supported by a simple mixing model that predicted E. coli concentrations based on salinity measurements. Additionally, an assessment of a sentinel monitoring station suggested routine monitoring locations may produce conservative estimates of E. coli concentrations in stratified estuaries. Copyright © 2016 Elsevier Ltd. All rights reserved.
Off Axis Growth of Strontium Titanate Films with High Dielectric Constant Tuning and Low Loss
2003-04-03
80309, U.S.A. ABSTRACT We have measured the nonlinear dielectric properties of strontium titanate (STO) thin films grown on neodymium gallate (NGO...and lanthanum aluminate (LAO) substrates. The films prepared by off-axis pulsed laser deposition were characterized by their dielectric constant and...performed on the films prepared with the off axis growth. EXPERIMENTAL Pulsed laser deposition (PLD) was used to deposit STO films on lanthanum
Haldar, Raktim; Banik, Abhik D; Varshney, Shailendra K
2014-09-22
In this work, we propose and demonstrate the performance of silicon-on-insulator (SOI) off-axis microring resonator (MRR) as electro-optic modulator (EOM). Adding an extra off-axis inner-ring in conventional microring structure provides control to compensate thermal effects on EOM. It is shown that dynamically controlled bias-voltage applied to the outer ring has the potency to quell the thermal effects over a wide range of temperature. Thus, besides the appositely biased conventional microring, off-axis inner microring with pre-emphasized electrical input message signal enables our proposed structure suitable for high data-rate dense wavelength division multiplexing scheme of optical communication within a very compact device size.
NASA Astrophysics Data System (ADS)
Tsesarsky, M.; Volk, O.; Shani-Kadmiel, S.; Gvirtzman, Z.
2016-12-01
Sedimentary wedges underlay many coastal areas, specifically along passive continental margins. Although a large portion of the world`s population is concentrated along coastal areas, relatively few studies investigated the seismic hazard related to internal structure of these wedges. This is particularly important, when the passive margin is located in proximity to active plate boundaries. Sedimentry wedges have low angles compared to fault bounded basins, hence commonly treated using 1D methods. In various locations the sedimentary wedges are transected by deep buried canyons typically filled with sediments softer than their surrounding bedrock. Such structures are found is the Mediterranean coast of Israel. Here, a sedimentary wedge and buried canyons underlay some of the country's most densely populated regions. Seismic sources can be found both at sea and on land at epicentral distances ranging from 50 to 200 km. Although this region has a proven seismic record, it has, like many other parts of the world, limited instrumental coverage and long return periods. This makes assessment of ground motions in a future earthquake difficult and highlights the importance of non-instrumental methods. We employ numerical modeling (SW4 FD code) to study seismic ground motions and their amplification atop the sedimentary wedge and canyons. This goal is a part of a larger objective aiming at developing a systematic approach for distinction between individual contributions of basin structures to the highly complex overall basin response. We show that the sedimentary wedge and buried canyon both exhibit a unique response and modeling them as one-dimensional structures could significantly underestimate seismic hazard. The sedimentary wedge exhibit amplification ratios, relative to a horizontally layered model, up to a factor of 2. This is mainly due to the amplification of Rayleigh waves traveling into the wedge from its thin side. The buried canyon structure shows a simple, "easy to use" response with considerably high PGV values and amplification ratios of up to 3 along its axis. This response is due to a geometrical focusing effect caused by the convex shape of the canyon's floor. The canyon's response is significant even where the canyon is buried deep under the surface.
NASA Technical Reports Server (NTRS)
Mansur, M. Hossein; Tischler, Mark B.
1997-01-01
Historically, component-type flight mechanics simulation models of helicopters have been unable to satisfactorily predict the roll response to pitch stick input and the pitch response to roll stick input off-axes responses. In the study presented here, simple first-order low-pass filtering of the elemental lift and drag forces was considered as a means of improving the correlation. The method was applied to a blade-element model of the AH-64 APache, and responses of the modified model were compared with flight data in hover and forward flight. Results indicate that significant improvement in the off-axes responses can be achieved in hover. In forward flight, however, the best correlation in the longitudinal and lateral off-axes responses required different values of the filter time constant for each axis. A compromise value was selected and was shown to result in good overall improvement in the off-axes responses. The paper describes both the method and the model used for its implementation, and presents results obtained at hover and in forward flight.
Diamond Machining of an Off-Axis Biconic Aspherical Mirror
NASA Technical Reports Server (NTRS)
Ohl, Raymond G.; Preuss, Werner; Sohn, Alex; MacKenty, John
2009-01-01
Two diamond-machining methods have been developed as part of an effort to design and fabricate an off-axis, biconic ellipsoidal, concave aluminum mirror for an infrared spectrometer at the Kitt Peak National Observatory. Beyond this initial application, the methods can be expected to enable satisfaction of requirements for future instrument mirrors having increasingly complex (including asymmetrical), precise shapes that, heretofore, could not readily be fabricated by diamond machining or, in some cases, could not be fabricated at all. In the initial application, the mirror is prescribed, in terms of Cartesian coordinates x and y, by aperture dimensions of 94 by 76 mm, placements of -2 mm off axis in x and 227 mm off axis in y, an x radius of curvature of 377 mm, a y radius of curvature of 407 mm, an x conic constant of 0.078, and a y conic constant of 0.127. The aspect ratio of the mirror blank is about 6. One common, "diamond machining" process uses single-point diamond turning (SPDT). However, it is impossible to generate the required off-axis, biconic ellipsoidal shape by conventional SPDT because (1) rotational symmetry is an essential element of conventional SPDT and (2) the present off-axis biconic mirror shape lacks rotational symmetry. Following conventional practice, it would be necessary to make this mirror from a glass blank by computer-controlled polishing, which costs more than diamond machining and yields a mirror that is more difficult to mount to a metal bench. One of the two present diamond machining methods involves the use of an SPDT machine equipped with a fast tool servo (FTS). The SPDT machine is programmed to follow the rotationally symmetric asphere that best fits the desired off-axis, biconic ellipsoidal surface. The FTS is actuated in synchronism with the rotation of the SPDT machine to generate the difference between the desired surface and the best-fit rotationally symmetric asphere. In order to minimize the required stroke of the FTS, the blanks were positioned at a large off-axis distance and angle, and the axis of the FTS was not parallel to the axis of the spindle of the SPDT machine. The spindle was rotated at a speed of 120 rpm, and the maximum FTS speed was 8.2 mm/s.
NASA Astrophysics Data System (ADS)
Fujii, M.; Okino, K.; Honsho, C.; Mochizuki, N.; Szitkar, F.; Dyment, J.
2013-12-01
Near-bottom magnetic profiling using submersible, deep-tow, Remotely Operated Vehicle (ROV) and Autonomous Underwater Vehicle (AUV) make possible to conduct high-resolution surveys and depict detailed magnetic features reflecting, for instance, the presence of fresh lavas or hydrothermal alteration, or geomagnetic paleo-intensity variations. We conducted near-bottom three component magnetic measurements onboard submersible Shinkai 6500 in the Southern Mariana Trough, where five active hydrothermal vent fields (Snail, Yamanaka, Archean, Pica, and Urashima sites) have been found in both on- and off-axis areas of the active back-arc spreading center, to detect signals from hydrothermally altered rock and to distinguish old and new submarine lava flows. Fourteen dives were carried out at an altitude of 1-40 m during the R/V Yokosuka YK10-10 and YK10-11 cruises in 2010. We carefully corrected the effect of the induced and permanent magnetizations of the submersible by applying the correction method for the shipboard three-component magnetometer measurement modified for deep-sea measurement, and subtracted the IGRF values from the corrected data to obtain geomagnetic vector anomalies along the dive tracks. We then calculated the synthetic magnetic vector field produced by seafloor, assumed to be uniformly magnetized, using three dimensional forward modeling. Finally, values of the absolute magnetizations were estimated by using a linear transfer function in the Fourier domain from the observed and synthetic magnetic anomalies. The distribution of estimated absolute magnetization generally shows low values around the five hydrothermal vent sites. This result is consistent with the equivalent magnetization distribution obtained from previous AUV survey data. The areas of low magnetization are also consistent with hydrothermal deposits identified in video records. These results suggest that low magnetic signals are due to hydrothermal alteration zones where host rocks are demagnetized by hydrothermal circulation. The low magnetization zones around the off-axis vent sites are about ten times wider than those surrounding the on-axis sites, possibly reflecting the longer duration of hydrothermal circulation at these sites. Another interesting result is that the absolute magnetization shows extremely high intensities (>80 A/m) at the neo volcanic zones (NVZ) and relatively low intensities (<10 A/m) two to five kilometers away from the NVZ. These variations are quite consistent with those of the Natural Remanent Magnetization measured on basalt samples, suggesting that the low-temperature oxidation of host rock due to the reaction with seawater has completed within a few kilometers distance from the spreading axis. We conclude that the magnetization of the uppermost oceanic crust decreases with age due to the combination of the both hydrothermal rapid alteration and the low-temperature gradual alteration processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Hee Jung; Department of Biomedical Engineering, Seoul National University, Seoul; Department of Radiation Oncology, Soonchunhyang University Hospital, Seoul
2015-01-01
To investigate how accurately treatment planning systems (TPSs) account for the tongue-and-groove (TG) effect, Monte Carlo (MC) simulations and radiochromic film (RCF) measurements were performed for comparison with TPS results. Two commercial TPSs computed the TG effect for Varian Millennium 120 multileaf collimator (MLC). The TG effect on off-axis dose profile at 3 depths of solid water was estimated as the maximum depth and the full width at half maximum (FWHM) of the dose dip at an interleaf position. When compared with the off-axis dose of open field, the maximum depth of the dose dip for MC and RCF rangedmore » from 10.1% to 20.6%; the maximum depth of the dose dip gradually decreased by up to 8.7% with increasing depths of 1.5 to 10 cm and also by up to 4.1% with increasing off-axis distances of 0 to 13 cm. However, TPS results showed at most a 2.7% decrease for the same depth range and a negligible variation for the same off-axis distances. The FWHM of the dose dip was approximately 0.19 cm for MC and 0.17 cm for RCF, but 0.30 cm for Eclipse TPS and 0.45 cm for Pinnacle TPS. Accordingly, the integrated value of TG dose dip for TPS was larger than that for MC and RCF and almost invariant along the depths and off-axis distances. We concluded that the TG dependence on depth and off-axis doses shown in the MC and RCF results could not be appropriately modeled by the TPS versions in this study.« less
Experimental Validation Techniques for the Heleeos Off-Axis Laser Propagation Model
2010-03-01
EXPERIMENTAL VALIDATION TECHNIQUES FOR THE HELEEOS OFF-AXIS LASER PROPAGATION MODEL THESIS John Haiducek, 1st Lt, USAF AFIT/GAP/ENP/10-M07 DEPARTMENT...Department of Defense, or the United States Government. AFIT/GAP/ENP/10-M07 EXPERIMENTAL VALIDATION TECHNIQUES FOR THE HELEEOS OFF-AXIS LASER ...BS, Physics 1st Lt, USAF March 2010 APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED. AFIT/GAP/ENP/10-M07 Abstract The High Energy Laser End-to-End
2011-11-01
ply unidirectional carbon/epoxy laminates [0]12 were fabricated from the prepreg tape of P3252-20 (TORAY). They were laid up by hand and cured in...Off-Axis Ratcheting Behavior of Unidirectional Carbon/Epoxy Laminate under Asymmetric Cyclic Loading at High Temperature Takafumi Suzuki 1 and...Development of an engineering model for predicting the off-axis ratcheting behavior of a unidirectional CFRP laminate has been attempted. For this purpose
Ridge-crossing mantle plumes and gaps in tracks
NASA Astrophysics Data System (ADS)
Sleep, Norman H.
2002-12-01
Hot spot tracks approach, cross, and leave ridge axes. The complications of this process make it difficult to determine the track followed by a plume and the evolution of its vigor. When a plume is sufficiently near the ridge axis, buoyant plume material flows along the base of the lithosphere toward the axis, forming an on-axis hot spot. The track of the on-axis hot spot is a symmetric V on both plates and an unreliable indication of the path followed by the plume. Aseismic ridges form more or less along flowlines from a plume to a ridge axis when channels form at the base of the lithosphere. A dynamic effect is that off-axis hot spots appear to shut off at the time that an on-axis hot spot becomes active along an axis-approaching track. This produces a gap in the obvious track and a jump of the hot spot to the ridge axis. The gap results from the effects of ponded plume material on intraplate (membrane) stress. Membrane tension lets dikes ascend efficiently to produce obvious tracks of edifices. An off-axis hot spot shuts down when the plume is sufficiently near the ridge axis that plume material flows there, putting the nearby lithosphere above the plume into compression, preventing dikes. In addition, the off-axis thickness of plume material, which produces membrane tension, decreases as the slope of the base of the lithosphere increases beneath young lithosphere. Slow spreading rates favor gaps produced in this way. Gaps are observed near both fast and slow ridges.
Propagation dynamics of off-axis symmetrical and asymmetrical vortices embedded in flat-topped beams
NASA Astrophysics Data System (ADS)
Zhang, Xu; Wang, Haiyan
2017-11-01
In this paper, propagation dynamics of off-axis symmetrical and asymmetrical optical vortices(OVs) embedded in flat-topped beams have been explored numerically based on rigorous scalar diffraction theory. The distribution properties of phase and intensity play an important role in driving the propagation dynamics of OVs. Numerical results show that the single off-axis vortex moves in a straight line. The displacement of the single off-axis vortex becomes smaller, when either the order of flatness N and the beam size ω0are increased or the off-axis displacement d is decreased. In addition, the phase singularities of high order vortex beams can be split after propagating a certain distance. It is also demonstrated that the movement of OVs are closely related with the spatial symmetrical or asymmetrical distribution of vortex singularities field. Multiple symmetrical and asymmetrical optical vortices(OVs) embedded in flat-topped beams can interact and rotate. The investment of the propagation dynamics of OVs may have many applications in optical micro-manipulation and optical tweezers.
NASA Astrophysics Data System (ADS)
West, S. C.; Burge, J. H.; Cuerden, B.; Davison, W.; Hagen, J.; Martin, H. M.; Tuell, M. T.; Zhao, C.; Zobrist, T.
2010-07-01
The Giant Magellan Telescope has a 25 meter f/0.7 near-parabolic primary mirror constructed from seven 8.4 meter diameter segments. Several aspects of the interferometric optical test used to guide polishing of the six off-axis segments go beyond the demonstrated state of the art in optical testing. The null corrector is created from two obliquelyilluminated spherical mirrors combined with a computer-generated hologram (the measurement hologram). The larger mirror is 3.75 m in diameter and is supported at the top of a test tower, 23.5 m above the GMT segment. Its size rules out a direct validation of the wavefront produced by the null corrector. We can, however, use a reference hologram placed at an intermediate focus between the two spherical mirrors to measure the wavefront produced by the measurement hologram and the first mirror. This reference hologram is aligned to match the wavefront and thereby becomes the alignment reference for the rest of the system. The position and orientation of the reference hologram, the 3.75 m mirror and the GMT segment are measured with a dedicated laser tracker, leading to an alignment accuracy of about 100 microns over the 24 m dimensions of the test. In addition to the interferometer that measures the GMT segment, a separate interferometer at the center of curvature of the 3.75 m sphere monitors its figure simultaneously with the GMT measurement, allowing active correction and compensation for residual errors. We describe the details of the design, alignment, and use of this unique off-axis optical test.
Suppression of Speckles at High Adaptive Correction Using Speckle Symmetry
NASA Technical Reports Server (NTRS)
Bloemhof, Eric E.
2006-01-01
Focal-plane speckles set important sensitivity limits on ground- or space-based imagers and coronagraphs that may be used to search for faint companions, perhaps ultimately including exoplanets, around stars. As speckles vary with atmospheric fluctuations or with drifting beamtrain aberrations, they contribute speckle noise proportional to their full amplitude. Schemes to suppress speckles are thus of great interest. At high adaptive correction, speckles organize into species, represented by algebraic terms in the expansion of the phase exponential, that have distinct spatial symmetry, even or odd, under spatial inversion. Filtering speckle patterns by symmetry may eliminate a disproportionate fraction of the speckle noise while blocking (only) half of the image signal from the off-axis companion being sought. The fraction of speckle power and hence of speckle noise in each term will vary with degree of correction, and so also will the net symmetry in the speckle pattern.
NASA Astrophysics Data System (ADS)
Yamaguchi, M.; Hashimoto, Y.
2012-12-01
Evolution of physical properties of sediments along subduction interface has effects on wedge strength, wedge geometry, dewatering and dehydration processes, and seismic behavior. Sediments have initially more than 70% of porosity prior to subduction. Through underthrusting and accretion, porosity of sediments decreases by compaction and cementation to be lithified sediments. The purpose of this study is to understand evolution of physical properties from a state before subduction to a state within a wedge using a relationship between compressional-wave velocity and porosity. In this study, we obtained new data for sediments from a reference site in IODP NanTroSEIZE, Expedition 333. In addition to that, we have complied velocity-porosity relationships for the samples and also for previous studies from NanTroSEIZE (off Kumano) (Hashimoto et al., 2010, 2011), ODP Leg 190 (off Shikoku) (Hoffman and Tobin, 2004) and ODP Leg 170 (off Costa Rica) (Gettemy and Tobin, 2003). Velocity measurement procedure in this study to obtain new data is as following: Two pumps were used to control pore fluid pressure and confining pressure. The pore pressure of 1000kPa was kept under drained conditions. Confining (effective) pressure was increased stepwise in the measurements. Velocity measurements were conducted under isotropic pressure conditions. Confining pressure was pressurized in tens seconds and kept for more than 8 hours for next step to obtain equilibrium conditions between effective pressure and sediments strain. Lead zirconate titanate (PZT) shear wave transducers (500kHz) were used in a source-receiver pair to measure wave speed. Porosity and P-wave velocity ranges about 27 - 75% and 1.4 - 2.2 km/s in this study, respectively. In the comparison in Vp-porosity relationships between sedimetns from reference sites and others, sediments were classified into two, simply compacted sediments (reference site and slope sediments) and wedge sediments. Different trends in Vp-porosity relationships were observed for the classified sediments. For compacted sediments, Vp-porosity relationships are along the global empirical relationships (Erickson and Jarrard 1988) and almost within the area between normal and highly compaction curves. On the other hand, some of Vp-porosity relationships for wedge sediments represent trends with higher velocity at a porosity. Such trend was observed for wedge sediments from Site C0001 and C0004. Those higher Vp trend in Vp-porosity relationship for wedge sediments can be explained by shear strain of sediments and/or cementation. Even though the velocity measurements was conducted under hydrostatic condition, we examined the void ratio-porosity curve as a kind of compaction curve. On the basis of the curves, break points were observed at the pressure which corresponds to the effective pressure assuming the hydrostatic pore fluid pressure. The result suggests that the sediments were under condition of normal compaction. Some of void ratio-porosity curve represent a evidence of weak cement which can correspond with anomaly in porosity-depth curve in the shallow portion of the reference sites.
Pape, D; Adam, F; Rupp, S; Seil, R; Kohn, D
2004-02-01
In high tibial closing-wedge osteotomies (HTO), closure of an osteotomy gap after resection of a bony wedge can be associated with a fissure of the medial cortex of the tibial head (MCT). The effect of a broken MCT on the recurrence of varus deformity is disputed. In this study, serial roentgen stereometric analysis (RSA) was used to determine the fixation stability of a rigid internal "L" plate after HTO. Full weight lower limb radiographs were used to determine the sagittal alignment in patients with varying degrees of varus malalignment and correction over time. Forty-two patients with varus gonarthrosis stage I-III (Ahlback) were treated with HTO and internal fixation with an L-shaped rigid plate. Patients were followed by serial RSA, conventional radiographs, and clinical evaluation (Hospital of Special Surgery score) over a 12-month period. In 19 of 42 successive patients, an average wedge size of 6.9 degrees was resected leaving the MCT intact (group 1). In 23 of 42 of patients, the MCT was unintentionally fissured during surgery when an average 10.3 degrees -wedge was resected (group 2). In group 2, RSA revealed a fivefold increase in lateral displacement of the distal tibial segment within 3 weeks after HTO. Twelve weeks after HTO, translations between tibial segments were below the accuracy of the RSA setup in the majority of patients. Group 1 patients demonstrated a higher initial fixation stability, less occurrence of varus deformity, and a higher HSS score compared to patients with larger wedge sizes and frequent fracture of the MCT (group 2). Before bone healing is achieved, the integrity of the MCT plays a crucial role for the clinical and radiological outcome after HTO.
Measurement of νμ and νe Events in an Off-Axis Horn-Focused Neutrino Beam
NASA Astrophysics Data System (ADS)
Adamson, P.; Aguilar-Arevalo, A. A.; Anderson, C. E.; Bazarko, A. O.; Bishai, M.; Brice, S. J.; Brown, B. C.; Bugel, L.; Cao, J.; Choudhary, B. C.; Coney, L.; Conrad, J. M.; Cox, D. C.; Curioni, A.; Djurcic, Z.; Finley, D. A.; Fleming, B. T.; Ford, R.; Gallagher, H. R.; Garcia, F. G.; Garvey, G. T.; Green, C.; Green, J. A.; Harris, D.; Hart, T. L.; Hawker, E.; Hylen, J.; Imlay, R.; Johnson, R. A.; Karagiorgi, G.; Kasper, P.; Katori, T.; Kobilarcik, T.; Kopp, S.; Kourbanis, I.; Koutsoliotas, S.; Laird, E. M.; Linden, S. K.; Link, J. M.; Liu, Y.; Liu, Y.; Loiacono, L.; Louis, W. C.; Marchionni, A.; Mahn, K. B. M.; Marsh, W.; McGregor, G.; Messier, M. D.; Metcalf, W.; Meyers, P. D.; Mills, F.; Mills, G. B.; Monroe, J.; Moore, C. D.; Nelson, J. K.; Nelson, R. H.; Nguyen, V. T.; Nienaber, P.; Nowak, J. A.; Ouedraogo, S.; Patterson, R. B.; Pavlovic, Z.; Perevalov, D.; Polly, C. C.; Prebys, E.; Raaf, J. L.; Ray, H.; Roe, B. P.; Russell, A. D.; Sandberg, V.; Schirato, R.; Schmitz, D.; Shaevitz, M. H.; Shoemaker, F. C.; Smart, W.; Smith, D.; Sodeberg, M.; Sorel, M.; Spentzouris, P.; Stancu, I.; Stefanski, R. J.; Sung, M.; Tanaka, H. A.; Tayloe, R.; Tzanov, M.; Vahle, P.; van de Water, R.; Viren, B.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Yang, H. J.; Yumiceva, F. X.; Zeller, G. P.; Zimmerman, E. D.; Zwaska, R.
2009-05-01
We report the first observation of off-axis neutrino interactions in the MiniBooNE detector from the NuMI beam line at Fermilab. The MiniBooNE detector is located 745 m from the NuMI production target, at 110 mrad angle (6.3°) with respect to the NuMI beam axis. Samples of charged-current quasielastic νμ and νe interactions are analyzed and found to be in agreement with expectation. This provides a direct verification of the expected pion and kaon contributions to the neutrino flux and validates the modeling of the NuMI off-axis beam.
Off-axis spectral beam combining of Bragg reflection waveguide photonic crystal diode lasers
NASA Astrophysics Data System (ADS)
Sun, Fangyuan; Wang, Lijie; Zhao, Yufei; Hou, Guanyu; Shu, Shili; Zhang, Jun; Peng, Hangyu; Tian, Sicong; Tong, Cunzhu; Wang, Lijun
2018-06-01
The spectral beam combining (SBC) of Bragg reflection waveguide photonic crystal (BRW-PC) diode lasers was studied for the first time. An off-axis feedback system was constructed using a stripe mirror and a spatial filter to control beam quality in the external cavity. It was found that the BRW-PC diode lasers with a low divergence and a circular beam provided a simplified and cost-effective SBC. The off-axis feedback broke the beam quality limit of a single element, and an M 2 factor of 3.8 times lower than that of a single emitter in the slow axis was demonstrated.
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1978-01-01
Finite element analyses were performed to investigate theoretically the effects of in-plane and out-of-plane eccentricities, bending or twisting, and thickness nonuniformity on the axial stress and strain variations across the width of off-axis specimens. The results are compared with measured data and are also used to assess the effects of these eccentricities on the fracture stress of off-axis fiber composites. Guidelines for detecting and minimizing the presence of eccentricities are described.
The effects of eccentricities on the fracture of off-axis fiber composites
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1978-01-01
Finite element analyses were performed to investigate theoretically the effects of in-plane and out-of plane eccentricities, bending or twisting, and thickness nonuniformity on the axial stress and strain variations across the width of off-axis specimens. The results are compared with measured data and are also used to access the effects of these eccentricities on the fracture stress of off-axis fiber composites. Guidelines for detecting and minimizing the presence of eccentricities are described.
Proximal metatarsal osteotomies: a comparative geometric analysis conducted on sawbone models.
Nyska, Meir; Trnka, Hans-Jörg; Parks, Brent G; Myerson, Mark S
2002-10-01
We evaluated the change in position of the first metatarsal head using a three-dimensional digitizer on sawbone models. Crescentic, closing wedge, oblique shaft (Ludloff 8 degrees and 16 degrees), reverse oblique shaft (Mau 8 degrees and 16 degrees), rotational "Z" (Scarf), and proximal chevron osteotomies were performed and secured using 3-mm screws. The 16 degrees Ludloff provided the most lateral shift (9.5 mm) and angular correction (14.5 degrees) but also produced the most elevation (1.4 mm) and shortening (2.9 mm). The 8 degrees Ludloff provided lateral and angular corrections similar to those of the crescentic and closing wedge osteotomies with less elevation and shortening. Because the displacement osteotomies (Scarf, proximal chevron) provided less angular correction, the same lateral displacement, and less shortening than the basilar angular osteotomies, based upon this model they can be more reliably used for a patient with a mild to moderate deformity, a short first metatarsal, or an intermediate deformity with a large distal metatarsal articular angle. These results can serve as recommendations for selecting the optimal osteotomy with which to correct a deformation.
Floating aerial 3D display based on the freeform-mirror and the improved integral imaging system
NASA Astrophysics Data System (ADS)
Yu, Xunbo; Sang, Xinzhu; Gao, Xin; Yang, Shenwu; Liu, Boyang; Chen, Duo; Yan, Binbin; Yu, Chongxiu
2018-09-01
A floating aerial three-dimensional (3D) display based on the freeform-mirror and the improved integral imaging system is demonstrated. In the traditional integral imaging (II), the distortion originating from lens aberration warps elemental images and degrades the visual effect severely. To correct the distortion of the observed pixels and to improve the image quality, a directional diffuser screen (DDS) is introduced. However, the improved integral imaging system can hardly present realistic images with the large off-screen depth, which limits floating aerial visual experience. To display the 3D image in the free space, the off-axis reflection system with the freeform-mirror is designed. By combining the improved II and the designed freeform optical element, the floating aerial 3D image is presented.
WE-G-BRA-04: Common Errors and Deficiencies in Radiation Oncology Practice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kry, S; Dromgoole, L; Alvarez, P
Purpose: Dosimetric errors in radiotherapy dose delivery lead to suboptimal treatments and outcomes. This work reviews the frequency and severity of dosimetric and programmatic errors identified by on-site audits performed by the IROC Houston QA center. Methods: IROC Houston on-site audits evaluate absolute beam calibration, relative dosimetry data compared to the treatment planning system data, and processes such as machine QA. Audits conducted from 2000-present were abstracted for recommendations, including type of recommendation and magnitude of error when applicable. Dosimetric recommendations corresponded to absolute dose errors >3% and relative dosimetry errors >2%. On-site audits of 1020 accelerators at 409 institutionsmore » were reviewed. Results: A total of 1280 recommendations were made (average 3.1/institution). The most common recommendation was for inadequate QA procedures per TG-40 and/or TG-142 (82% of institutions) with the most commonly noted deficiency being x-ray and electron off-axis constancy versus gantry angle. Dosimetrically, the most common errors in relative dosimetry were in small-field output factors (59% of institutions), wedge factors (33% of institutions), off-axis factors (21% of institutions), and photon PDD (18% of institutions). Errors in calibration were also problematic: 20% of institutions had an error in electron beam calibration, 8% had an error in photon beam calibration, and 7% had an error in brachytherapy source calibration. Almost all types of data reviewed included errors up to 7% although 20 institutions had errors in excess of 10%, and 5 had errors in excess of 20%. The frequency of electron calibration errors decreased significantly with time, but all other errors show non-significant changes. Conclusion: There are many common and often serious errors made during the establishment and maintenance of a radiotherapy program that can be identified through independent peer review. Physicists should be cautious, particularly in areas highlighted herein that show a tendency for errors.« less
Research on the space-borne coherent wind lidar technique and the prototype experiment
NASA Astrophysics Data System (ADS)
Gao, Long; Tao, Yuliang; An, Chao; Yang, Jukui; Du, Guojun; Zheng, Yongchao
2016-10-01
Space-borne coherent wind lidar technique is considered as one of the most promising and appropriate remote Sensing methods for successfully measuring the whole global vector wind profile between the lower atmosphere and the middle atmosphere. Compared with other traditional methods, the space-borne coherent wind lidar has some advantages, such as, the all-day operation; many lidar systems can be integrated into the same satellite because of the light-weight and the small size, eye-safe wavelength, and being insensitive to the background light. Therefore, this coherent lidar could be widely applied into the earth climate research, disaster monitoring, numerical weather forecast, environment protection. In this paper, the 2μm space-borne coherent wind lidar system for measuring the vector wind profile is proposed. And the technical parameters about the sub-system of the coherent wind lidar are simulated and the all sub-system schemes are proposed. For sake of validating the technical parameters of the space-borne coherent wind lidar system and the optical off-axis telescope, the weak laser signal detection technique, etc. The proto-type coherent wind lidar is produced and the experiments for checking the performance of this proto-type coherent wind lidar are finished with the hard-target and the soft target, and the horizontal wind and the vertical wind profile are measured and calibrated, respectively. For this proto-type coherent wind lidar, the wavelength is 1.54μm, the pulse energy 80μJ, the pulse width 300ns, the diameter of the off-axis telescope 120mm, the single wedge for cone scanning with the 40°angle, and the two dualbalanced InGaAs detector modules are used. The experiment results are well consisted with the simulation process, and these results show that the wind profile between the vertical altitude 4km can be measured, the accuracy of the wind velocity and the wind direction are better than 1m/s and +/-10°, respectively.
Database of Inlet and Exhaust Noise Shielding for Wedge-Shaped Airframe
NASA Technical Reports Server (NTRS)
Gerhold, Carl H.; Clark, Lorenzo R.
2001-01-01
An experiment to measure the noise shielding of the blended wing body design concept was developed using a simplified wedge-shaped airframe. The experimental study was conducted in the Langley Anechoic Noise Research Facility. A wideband, omnidirective sound source in a simulated engine nacelle was held at locations representative of a range of engine locations above the wing. The sound field around the model was measured with the airframe and source in place and with source alone, using an-array of microphones on a rotating hoop that is also translated along an axis parallel to the airframe axis. The insertion loss was determined from the difference between the two resulting contours. Although no attempt was made to simulate the noise characteristics of a particular engine, the broadband noise source radiated sound over a range of scaled frequencies encompassing 1 and 2 times the blade passage frequency representative of a large, high-bypass-ratio turbofan engine. The measured data show that significant shielding of the inlet-radiated noise is obtained in the area beneath and upstream of the model. The data show the sensitivity of insertion loss to engine location.
Binocular Coordination of the Human Vestibulo-Ocular Reflex during Off-axis Pitch Rotation
NASA Technical Reports Server (NTRS)
Wood, S. J.; Reschke, M. F.; Kaufman, G. D.; Black, F. O.; Paloski, W. H.
2006-01-01
Head movements in the sagittal pitch plane typically involve off-axis rotation requiring both vertical and horizontal vergence ocular reflexes to compensate for angular and translational motion relative to visual targets of interest. The purpose of this study was to compare passive pitch VOR responses during rotation about an Earth-vertical axis (canal only cues) with off-axis rotation (canal and otolith cues). Methods. Eleven human subjects were oscillated sinusoidally at 0.13, 0.3 and 0.56 Hz while lying left-side down with the interaural axis either aligned with the axis of rotation or offset by 50 cm. In a second set of measurements, twelve subjects were also tested during sinusoidally varying centrifugation over the same frequency range. The modulation of vertical and horizontal vergence ocular responses was measured with a binocular videography system. Results. Off-axis pitch rotation enhanced the vertical VOR at lower frequencies and enhanced the vergence VOR at higher frequencies. During sinusoidally varying centrifugation, the opposite trend was observed for vergence, with both vertical and vergence vestibulo-ocular reflexes being suppressed at the highest frequency. Discussion. These differential effects of off-axis rotation over the 0.13 to 0.56 Hz range are consistent with the hypothesis that otolith-ocular reflexes are segregated in part on the basis of stimulus frequency. At the lower frequencies, tilt otolith-ocular responses compensate for declining canal input. At higher frequencies, translational otolith-ocular reflexes compensate for declining visual contributions to the kinematic demands required for fixating near targets.
NASA Astrophysics Data System (ADS)
Cromar, P. F.
1984-12-01
In this thesis results are presented from a study of the off-axis X and Gamma radiation field caused by a highly relativistic electron beam in liquid Nitrogen at various path lengths out to 2 radiation lengths. The off-axis dose in Silicon was calculated using electron/photon transport code CYLTRAN and measured using thermal luminescent dosimeters (TLD's). Calculations were performed on a CDC-7600 computer ar Los Alamos National Laboratory and measurements were made using the Naval Postgraduate School 100 Mev Linac. Comparison of the results is made and CYLTRAN is found to be in agreement with experimentally measured values. The CYLTRAN results are extended to the off-axis dose caused by a 100 Mev electron beam in air at Standard Temperature and Pressure (STP).
NASA Technical Reports Server (NTRS)
Sinclair, J. H.; Chamis, C. C.
1977-01-01
The mechanical behavior, fracture surfaces, and fracture modes of unidirectional high-modulus graphite-fiber/epoxy composites subjected to off-axis tensile loads were investigated experimentally. The investigation included the generation of stress-strain-to-fracture data and scanning electron microscope studies of the fractured surfaces. The results led to the identification of fracture modes and distinct fracture surface characteristics for off-axis tensile loading. The results also led to the formulation of critical for identifying and characterizing these fracture modes and their associated fracture surfaces. The results presented and discussed herein were used in the theoretical investigation and comparisons described in Part 2. These results should also provide a good foundation for identifying, characterizing, and quantifying fracture modes in both off-axis and angle-plied laminates.
Single-shot dual-wavelength in-line and off-axis hybrid digital holography
NASA Astrophysics Data System (ADS)
Wang, Fengpeng; Wang, Dayong; Rong, Lu; Wang, Yunxin; Zhao, Jie
2018-02-01
We propose an in-line and off-axis hybrid holographic real-time imaging technique. The in-line and off-axis digital holograms are generated simultaneously by two lasers with different wavelengths, and they are recorded using a color camera with a single shot. The reconstruction is carried using an iterative algorithm in which the initial input is designed to include the intensity of the in-line hologram and the approximate phase distributions obtained from the off-axis hologram. In this way, the complex field in the object plane and the output by the iterative procedure can produce higher quality amplitude and phase images compared to traditional iterative phase retrieval. The performance of the technique has been demonstrated by acquiring the amplitude and phase images of a green lacewing's wing and a living moon jellyfish.
Opening wedge and anatomic-specific plates in foot and ankle applications.
Kluesner, Andrew J; Morris, Jason B
2011-08-01
As surgeons continually push to improve techniques and outcomes, anatomic-specific and procedure-specific fixation options are becoming increasingly available. The unique size, shape, and function of the foot provide an ideal framework for the use of anatomic-specific plates. These distinctive plate characteristics range from anatomic contouring and screw placements to incorporated step-offs and wedges. By optimizing support, compression, and stabilization, patients may return to weight bearing and activity sooner, improving outcomes. This article discusses anatomic-specific plates and their use in forefoot and rearfoot surgical procedures. Copyright © 2011 Elsevier Inc. All rights reserved.
High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator
Wack, L.; Ngwa, W.; Tryggestad, E.; Tsiamas, P.; Berbeco, R.; Ng, S.K.; Hesser, J.
2013-01-01
Purpose We have established a high-throughput Gafchromic film dosimetry protocol for narrow kilo-voltage beams in homogeneous and heterogeneous media for small-animal radiotherapy applications. The kV beam characterization is based on extensive Gafchromic film dosimetry data acquired in homogeneous and heterogeneous media. An empirical model is used for parameterization of depth and off-axis dependence of measured data. Methods We have modified previously published methods of film dosimetry to suit the specific tasks of the study. Unlike film protocols used in previous studies, our protocol employs simultaneous multichannel scanning and analysis of up to nine Gafchromic films per scan. A scanner and background correction were implemented to improve accuracy of the measurements. Measurements were taken in homogeneous and inhomogeneous phantoms at 220 kVp and a field size of 5 × 5 mm2. The results were compared against Monte Carlo simulations. Results Dose differences caused by variations in background signal were effectively removed by the corrections applied. Measurements in homogeneous phantoms were used to empirically characterize beam data in homogeneous and heterogeneous media. Film measurements in inhomogeneous phantoms and their empirical parameterization differed by about 2%–3%. The model differed from MC by about 1% (water, lung) to 7% (bone). Good agreement was found for measured and modelled off-axis ratios. Conclusions EBT2 films are a valuable tool for characterization of narrow kV beams, though care must be taken to eliminate disturbances caused by varying background signals. The usefulness of the empirical beam model in interpretation and parameterization of film data was demonstrated. PMID:23510532
Fruehn, J.; von Huene, Roland E.; Fisher, M.A.
1999-01-01
Subduction accretion and repeated terrane collision shaped the Alaskan convergent margin. The Yakutat Terrane is currently colliding with the continental margin below the central Gulf of Alaska. During the Neogene the terrane's western part was subducted after which a sediment wedge accreted along the northeast Aleutian Trench. This wedge incorporates sediment eroded from the continental margin and marine sediments carried into the subduction zone on the Pacific plate. Prestack depth migration was performed on six seismic reflection lines to resolve the structure within this accretionary wedge and its backstop. The lateral extent of the structures is constrained by high-resolution swath bathymetry and seismic lines collected along strike. Accretionary structure consists of variably sized thrust slices that were deformed against a backstop during frontal accretion and underplating. Toward the northeast the lower slope steepens, the wedge narrows, and the accreted volume decreases notwith-standing a doubling of sediments thickness in the trench. In the northeasternmost transect, near the area where the terrane's trailing edge subducts, no frontal accretion is observed and the slope is eroded. The structures imaged along the seismic lines discussed here most likely result from progressive evolution from erosion to accretion, as the trailing edge of the Yakutat Terrane is subducting.
Astigmatism correction of a non-imaging double spectrometer fitted with a 2D array detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yaney, P.P.; Ernst, S.L.; Blackshire, J.
1992-12-01
A SPEX 1401 double spectrometer was adapted for a liquid nitrogen cooled CCD detector to permit both spectral and spatial analysis of ceramic specimens in a laser Raman microprobe system. The exit image of the spectrometer suffers from astigmatism due to off-axis spherical mirrors. A cylindrical lens was added before the CCD to correct for the astigmatism. The spectrometer and several lenses were modeled using an optical ray tracing program to characterize the astigmatism and to optimize the locations of the lens and the detector. The astigmatism and the spot pattern sizes determined by the model were in good agreementmore » with he observed performance of the modified spectrometer-detector system. Typical spot patterns fell within the 23 {mu}m square pixel size.« less
Off-axis beam dynamics in rf-gun-based electron photoinjectors
Huang, R.; Mitchell, Chad; Papadopoulos, C.; ...
2016-11-22
The need to operate an rf-gun-based electron photoinjector with a beam emitted away from the cathode center can occur under various circumstances. First, in some cases the cathode can be affected by ion back-bombardment that progressively reduces the quantum efficiency (QE) in its center, making off-axis operation mandatory; second, in some cases the drive laser intensity can be sufficiently high to generate QE depletion in the cathode area illuminated by the laser, forcing off-axis operation; last, in cathodes with nonuniform QE distribution it could be convenient to operate off axis to exploit a better QE. However, operation in this modemore » may lead to growth of the projected transverse beam emittances due to correlations between the transverse and longitudinal degrees of freedom that are introduced within the gun and downstream rf cavities. A strategy is described to mitigate this emittance growth by allowing the beam to propagate along a carefully tuned off-axis trajectory in downstream rf cavities to remove the time-dependent rf kicks introduced in the gun. Along this trajectory, short range wakefields do not degrade the emittance, and long range wakefields degrade the emittance for very high repetition rate only.« less
Off-axis low coherence digital holographic interferometry for quantitative phase imaging with an LED
NASA Astrophysics Data System (ADS)
Guo, Rongli; Wang, Fan; Hu, Xiaoying; Yang, Wenqian
2017-11-01
Off-axis digital holographic interferometry with the light source of a light emitting diode (LED) is presented and its application for quantitative phase imaging in a large range with low noise is demonstrated. The scheme is implemented in a grating based Mach-Zehnder interferometer. To achieve off-axis interferometry, firstly, the collimated beam emitted from an LED is diffracted into multiple orders by a grating and they are split into two copies by a beam splitter; secondly, in the object arm the zero order of one copy is filtered in the Fourier plane and is reshaped to illuminate the sample, while in the reference arm one of its first order of another copy is selected to serve as the reference beam, and then an off-axis hologram can be obtained at the image plane. The main advantage stemming from an LED illumination is its high spatial phase resolution, due to the subdued speckle effect. The off-axis geometry enables one-shot recording of the hologram in the millisecond scale. The utility of the proposed setup is illustrated with measurements of a resolution target and part of a wing of green-lacewing, and dynamic evaporation process of an ethanol film.
Off-axis beam dynamics in rf-gun-based electron photoinjectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, R.; Mitchell, Chad; Papadopoulos, C.
The need to operate an rf-gun-based electron photoinjector with a beam emitted away from the cathode center can occur under various circumstances. First, in some cases the cathode can be affected by ion back-bombardment that progressively reduces the quantum efficiency (QE) in its center, making off-axis operation mandatory; second, in some cases the drive laser intensity can be sufficiently high to generate QE depletion in the cathode area illuminated by the laser, forcing off-axis operation; last, in cathodes with nonuniform QE distribution it could be convenient to operate off axis to exploit a better QE. However, operation in this modemore » may lead to growth of the projected transverse beam emittances due to correlations between the transverse and longitudinal degrees of freedom that are introduced within the gun and downstream rf cavities. A strategy is described to mitigate this emittance growth by allowing the beam to propagate along a carefully tuned off-axis trajectory in downstream rf cavities to remove the time-dependent rf kicks introduced in the gun. Along this trajectory, short range wakefields do not degrade the emittance, and long range wakefields degrade the emittance for very high repetition rate only.« less
Extremely Soft X-Ray Flash as the Indicator of Off-axis Orphan GRB Afterglow
NASA Astrophysics Data System (ADS)
Urata, Yuji; Huang, Kuiyun; Yamazaki, Ryo; Sakamoto, Takanori
2015-06-01
We verified the off-axis jet model of X-ray flashes (XRFs) and examined a discovery of off-axis orphan gamma-ray burst (GRB) afterglows. The XRF sample was selected on the basis of the following three factors: (1) a constraint on the lower peak energy of the prompt spectrum {E}{obs}{src}, (2) redshift measurements, and (3) multicolor observations of an earlier (or brightening) phase. XRF 020903 was the only sample selected on the basis of these criteria. A complete optical multicolor afterglow light curve of XRF 020903 obtained from archived data and photometric results in the literature showed an achromatic brightening around 0.7 days. An off-axis jet model with a large observing angle (0.21 rad, which is twice the jet opening half-angle, {θ }{jet}) can naturally describe the achromatic brightening and the prompt X-ray spectral properties. This result indicates the existence of off-axis orphan GRB afterglow light curves. Events with a larger viewing angle (\\gt ∼ 2{θ }{jet}) could be discovered using an 8 m class telescope with wide-field imagers such as the Subaru Hyper-Suprime-Cam and the Large Synoptic Survey Telescope.
The effect of plate position and size on tibial slope in high tibial osteotomy: a cadaveric study.
Rubino, L Joseph; Schoderbek, Robert J; Golish, S Raymond; Baumfeld, Joshua; Miller, Mark D
2008-01-01
Opening wedge high tibial osteotomies are performed for degenerative changes and varus. Opening wedge osteotomies can change proximal tibial slope in the sagittal plane, possibly imparting stability in the ACL-deficient knee. The aim of this study was to assess the effect of plate position and size on change in tibial slope. Eight cadaveric knees underwent opening wedge high tibial osteotomy with Puddu plates of each different size. Plates were placed anterior, central, and posterior for each size used. Lateral radiographs were obtained. Tibial slope was measured and compared with baseline slope. Tibial slope was affected by plate position (P < 0.05) and size (P < 0.001). Smaller, posterior plates had less effect on tibial slope. However, anterior and central plates increased tibial slope over all plate sizes (P < 0.05). This study found that tibial slope increases with opening wedge high tibial osteotomy. Larger corrections and anterior placement of the plate are associated with larger increases in slope.
Episodic plate separation and fracture infill on the surface of Europa
Sullivan, R.; Greeley, R.; Homan, K.; Klemaszewski, J.; Belton, M.J.S.; Carr, M.H.; Chapman, C.R.; Tufts, R.; Head, J. W.; Pappalardo, R.; Moore, J.; Thomas, P.
1998-01-01
Images obtained by the Voyager spacecraft revealed dark, wedge-shaped bands on Europa that were interpreted as evidence that surface plates, 50- 100 km across, moved and rotated relative to each other. This implied that they may be mechanically decoupled from the interior by a layer of warm ice or liquid water. Here we report similar features seen in higher resolution images (420 metres per pixel) obtained by the Galileo spacecraft that reveal new details of wedge-band formation. In particular, the interior of one dark band shows bilateral symmetry of parallel lineaments and pit complexes which indicates that plate separation occurred in discrete episodes from a central axis. The images also show that this style of tectonic activity involved plates < 10 km across. Although this tectonic style superficially resembles aspects of similar activity on Earth, such as sea-floor spreading and the formation of ice leads in polar seas, there are significant differences in the underlying physical mechanisms: the wedge-shaped bands on Europa most probably formed when lower material (ice or water) rose to fill the fractures that widened in response to regional surface stresses.
NASA Astrophysics Data System (ADS)
Miura, Sadahiko; Honjo, Hiroaki; Kinoshita, Keizo; Tokutome, Keiichi; Koike, Hiroaki; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo
2015-04-01
Perpendicular-anisotropy magnetic tunnel junctions (MTJs) were prepared on four substrate geometries, i.e., directly on the axis of the bottom electrode contact, directly off the axis of the bottom electrode contact, on the axis of the bottom electrode contact with a polished bottom electrode, and off the axis of the bottom electrode contact with a polished bottom electrode. Electrical shorts were observed for direct on-axis geometry at a certain extent, whereas there were no electrical shorts for the other three geometries. The MR ratio/σR, JC0, and thermal stability factor of the devices for polish on-axis geometry were almost the same as those for polish off-axis geometry. From TEM observations of the polish on-axis device, the interface between the bottom contact and the base electrode was determined to be rough, whereas the MgO barrier layer was determined to be smooth, indicating that the polish process was effective for smooth magnetic tunnel junction fabrication over the bottom contact. MTJs for polish on-axis geometry eliminated the base electrode resistance and increased the magnetoresistance ratio. This technology contributes to the higher density of spin transfer torque magnetic random access memory.
Stanley, Jeremy C; Robinson, Kerian G; Devitt, Brian M; Richmond, Anneka K; Webster, Kate E; Whitehead, Timothy S; Feller, Julian A
2016-03-01
There are numerous methods available to assist surgeons in the accurate correction of varus alignment during medial opening wedge high tibial osteotomy (MOWHTO). Preoperative planning performed with radiographs or more recently intraoperative computer navigation software has been used. The aim of the study was to compare the accuracy of computer navigated versus non-navigated techniques to correct varus alignment of the knee. The preoperative and postoperative radiographs of 117 knees that underwent MOWHTO were investigated to assess radiographic limb alignment 12-months postoperatively. The desired correction was defined as a weight bearing line (Mikulicz point {MP}) 58% of the width of the tibial plateau from the medial tibial margin. Sixty-five knees were corrected using a conventional technique and 52 knees were corrected using computer navigation. The mean MP percentage was 59% in the navigated group, compared with 56% in the fluoroscopic group (p=0.183). 51.9% of the navigation knees were corrected to within five percent of the desired correction, in contrast to 38.5% of the fluoroscopically corrected knees (p=0.15). 71.2% of the navigated knees were corrected to within 10% of the desired correction, compared with 63.1% of the fluoroscopically corrected knees (p=0.36). Large preoperative deformities were more accurately corrected with navigation assistance (57% vs 49%, p=0.049). No statistically significant difference was found in the radiographic correction of varus alignment twelve months postoperatively between navigated and fluoroscopic techniques of MOWHTO. However, a subgroup analysis demonstrated that larger preoperative varus deformities may be more accurately corrected using computer navigation. Copyright © 2016 Elsevier B.V. All rights reserved.
Random Vibration Analysis of the Tip-tilt System in the GMT Fast Steering Secondary Mirror
NASA Astrophysics Data System (ADS)
Lee, Kyoung-Don; Kim, Young-Soo; Kim, Ho-Sang; Lee, Chan-Hee; Lee, Won Gi
2017-09-01
A random vibration analysis was accomplished on the tip-tilt system of the fast steering secondary mirror (FSM) for the Giant Magellan Telescope (GMT). As the FSM was to be mounted on the top end of the secondary truss and disturbed by the winds, dynamic effects of the FSM disturbances on the tip-tilt correction performance was studied. The coupled dynamic responses of the FSM segments were evaluated with a suggested tip-tilt correction modeling. Dynamic equations for the tip-tilt system were derived from the force and moment equilibrium on the segment mirror and the geometric compatibility conditions with four design parameters. Statically stationary responses for the tip-tilt actuations to correct the wind-induced disturbances were studied with two design parameters based on the spectral density function of the star image errors in the frequency domain. Frequency response functions and root mean square values of the dynamic responses and the residual star image errors were numerically calculated for the off-axis and on-axis segments of the FSM. A prototype of on-axis segment of the FSM was developed for tip-tilt actuation tests to confirm the ratio of tip-tilt force to tip-tilt angle calculated from the suggested dynamic equations of the tip-tilt system. Tip-tilt actuation tests were executed at 4, 8 and 12 Hz by measuring displacements of piezoelectric actuators and reaction forces acting on the axial supports. The derived ratios of rms tip-tilt force to rms tip-tilt angle from tests showed a good correlation with the numerical results. The suggested process of random vibration analysis on the tip-tilt system to correct the wind-induced disturbances of the FSM segments would be useful to advance the FSM design and upgrade the capability to achieve the least residual star image errors by understanding the details of dynamics.
Off-Axis Seamount Lavas at 8°20' N Span the Entire Range of East Pacific Rise MORB Compositions
NASA Astrophysics Data System (ADS)
Anderson, M.; Wanless, V. D.; Perfit, M. R.; Gregg, P. M.; Fornari, D. J.; McCully, E.; Ridley, W. I.
2017-12-01
Lavas erupted at off-axis seamounts can provide a window into mantle heterogeneity and melting systematics that are not easily observed on-axis at fast-spreading mid-ocean ridges (MORs), where melts are efficiently mixed and homogenized within shallow axial magma chambers. To investigate off-axis magmatism, we systematically mapped the 8°20' N seamount chain in November of 2016 on R/V Atlantis using shipboard EM122 multibeam system and AUV Sentry. This 160-km long chain of off-axis seamounts and ridges is located perpendicular to the ridge axis, west of the East Pacific Rise (EPR) and north of the Siqueiros Fracture Zone. The high-resolution surface and AUV-based multibeam and AUV sidescan maps are combined with geochemical analyses of 300 basalt samples, collected using HOV Alvin and dredging, to evaluate magmatic plumbing and sources off-axis. Preliminary major and trace element concentrations reveal remarkable geochemical heterogeneity (including both normal and enriched basalt compositions) across the entire seamount chain and within individual seamounts. For example, (La/Sm)N contents span the entire range of known values for basalts from northern Pacific MORs and seamounts (0.45—2.76). MgO contents vary from 10.25 to 4.56 wt. % across the seamount chain and by as much as 3.61 wt. % from volcanic features sampled at an individual seamount (Beryl). Additionally, K2O/TiO2 ratios range from 4.9 to 61.3 across the seamount chain, and by as much as 54.4 at a single seamount (Beryl), indicating heterogeneous mantle sources or variable extents of melting occur at both regional and local scales. We combine the geochemical results and bathymetric maps with petrologic models to evaluate extents and depths of fractional crystallization and mantle melting in the off-axis environment.
Stable operating regime for traveling wave devices
Carlsten, Bruce E.
2000-01-01
Autophase stability is provided for a traveling wave device (TWD) electron beam for amplifying an RF electromagnetic wave in walls defining a waveguide for said electromagnetic wave. An off-axis electron beam is generated at a selected energy and has an energy noise inherently arising from electron gun. The off-axis electron beam is introduced into the waveguide. The off-axis electron beam is introduced into the waveguide at a second radius. The waveguide structure is designed to obtain a selected detuning of the electron beam. The off-axis electron beam has a velocity and the second radius to place the electron beam at a selected distance from the walls defining the waveguide, wherein changes in a density of the electron beam due to the RF electromagnetic wave are independent of the energy of the electron beam to provide a concomitant stable operating regime relative to the energy noise.
NASA Astrophysics Data System (ADS)
Krueger, Hannah E.; Wirth, Erin A.
2017-10-01
The Cascadia subduction zone exhibits along-strike segmentation in structure, processes, and seismogenic behavior. While characterization of seismic anisotropy can constrain deformation processes at depth, the character of seismic anisotropy in Cascadia remains poorly understood. This is primarily due to a lack of seismicity in the subducting Juan de Fuca slab, which limits shear wave splitting and other seismological analyses that interrogate the fine-scale anisotropic structure of the crust and mantle wedge. We investigate lower crustal anisotropy and mantle wedge structure by computing P-to-S receiver functions at 12 broadband seismic stations along the Cascadia subduction zone. We observe P-to-SV converted energy consistent with previously estimated Moho depths. Several stations exhibit evidence of an "inverted Moho" (i.e., a downward velocity decrease across the crust-mantle boundary), indicative of a serpentinized mantle wedge. Stations with an underlying hydrated mantle wedge appear prevalent from northern Washington to central Oregon, but sparse in southern Oregon and northern California. Transverse component receiver functions are complex, suggesting anisotropic and/or dipping crustal structure. To constrain the orientation of crustal anisotropy we compute synthetic receiver functions using manual forward modeling. We determine that the lower crust shows variable orientations of anisotropy along-strike, with highly complex anisotropy in northern Cascadia, and generally NW-SE and NE-SW orientations of slow-axis anisotropy in central and southern Cascadia, respectively. The orientations of anisotropy from this work generally agree with those inferred from shear wave splitting of tremor studies at similar locations, lending confidence to this relatively new method of inferring seismic anisotropy from slow earthquakes.
Point Spread Function of ASTRO-H Soft X-Ray Telescope (SXT)
NASA Technical Reports Server (NTRS)
Hayashi, Takayuki; Sato, Toshiki; Kikuchi, Naomichi; Iizuka, Ryo; Maeda, Yoshitomo; Ishida, Manabu; Kurashima, Sho; Nakaniwa, Nozomi; Okajima, Takashi; Mori, Hideyuki;
2016-01-01
ASTRO-H (Hitomi) satellite equips two Soft X-ray Telescopes (SXTs), one of which (SXT-S) is coupled to Soft-X-ray Spectrometer (SXS) while the other (SXT-I) is coupled to Soft X-ray Imager (SXI). Although SXTs are lightweight of approximately 42 kgmodule1 and have large on-axis effective area (EA) of approximately 450 cm(exp 2) at 4.5 keV module(sub 1) by themselves, their angular resolutions are moderate approximately 1.2 arcmin in half power diameter. The amount of contamination into the SXS FOV (3.05 times 3.05 arcmin(exp 2) from nearby sources was measured in the ground-based calibration at the beamline in Institute of Space and Astronautical Science. The contamination at 4.5 keV were measured with sources distant from the SXS center by one width of the FOV in perpendicular and diagonal directions, that is, 3 and 4.5 arcmin-off, respectively. The average EA of the contamination in the four directions with the 3 and 4.5 arcmin-off were measured to be 2 and 0.6% of the on-axis EA of 412 cm (exp) for the SXS FOV, respectively. The contamination from a source distant by two FOV widths in a diagonal direction, that is, 8.6 arcmin-off was measured to be 0.1% of the on-axis at 4.5 keV. The contamination amounts were also measured at 1.5 keV and 8.0 keV which indicated that the ratio of the contamination EA to that of on-axis hardly depended on the source energy. The off-axis SXT-I images from 4.5 to 27 arcmin were acquired at intervals of -4.5 arcmin for the SXI FOV of 38 times 38 arcmin(exp 2). The image shrinked as the off-axis angle increased. Above 13.5 arcmin of off-angle, a stray appeared around the image center in the off-axis direction. As for the on-axis image, a ring-shaped stray appeared at the edge of SXI of approximately 18 arcmin distant from the image center.
Experimental assessment of theory for refraction of sound by a shear layer
NASA Technical Reports Server (NTRS)
Schlinker, R. H.; Amiet, R. K.
1978-01-01
The refraction angle and amplitude changes associated with sound transmission through a circular, open-jet shear layer were studied in a 0.91 m diameter open jet acoustic research tunnel. Free stream Mach number was varied from 0.1 to 0.4. Good agreement between refraction angle correction theory and experiment was obtained over the test Mach number, frequency and angle measurement range for all on-axis acoustic source locations. For off-axis source positions, good agreement was obtained at a source-to-shear layer separation distance greater than the jet radius. Measureable differences between theory and experiment occurred at a source-to-shear layer separation distance less than one jet radius. A shear layer turbulence scattering experiment was conducted at 90 deg to the open jet axis for the same free stream Mach numbers and axial source locations used in the refraction study. Significant discrete tone spectrum broadening and tone amplitude changes were observed at open jet Mach numbers above 0.2 and at acoustic source frequencies greater than 5 kHz. More severe turbulence scattering was observed for downstream source locations.
Off-axis full-field swept-source optical coherence tomography using holographic refocusing
NASA Astrophysics Data System (ADS)
Hillmann, Dierck; Franke, Gesa; Hinkel, Laura; Bonin, Tim; Koch, Peter; Hüttmann, Gereon
2013-03-01
We demonstrate a full-field swept-source OCT using an off-axis geometry of the reference illumination. By using holographic refocusing techniques, a uniform lateral resolution is achieved over the measurement depth of approximately 80 Rayleigh lengths. Compared to a standard on-axis setup, artifacts and autocorrelation signals are suppressed and the measurement depth is doubled by resolving the complex conjugate ambiguity. Holographic refocusing was done efficiently by Fourier-domain resampling as demonstrated before in inverse scattering and holoscopy. It allowed to reconstruct a complete volume with about 10μm resolution over the complete measurement depth of more than 10mm. Off-axis full-field swept-source OCT enables high measurement depths, spanning many Rayleigh lengths with reduced artifacts.
Large-aperture interferometer using local reference beam
NASA Technical Reports Server (NTRS)
Howes, W. L.
1982-01-01
A large-aperture interferometer was devised by adding a local-reference-beam-generating optical system to a schlieren system. Two versions of the interferometer are demonstrated, one employing 12.7 cm (5 in.) diameter schlieren optics, the other employing 30.48 cm (12 in.) diameter parabolic mirrors in an off-axis system. In the latter configuration a cylindrical lens is introduced near the light source to correct for astigmatism. A zone plate is a satisfactory decollimating element in the reference-beam arm of the interferometer. Attempts to increase the flux and uniformity of irradiance in the reference beam by using a diffuser are discussed.
Metrology of flat mirrors with a computer generated hologram
NASA Astrophysics Data System (ADS)
Pariani, Giorgio; Tresoldi, Daniela; Moschetti, Manuele; Riva, Marco; Bianco, Andrea; Zerbi, Filippo Maria
2014-07-01
We designed the interferometric test of a 300 mm flat mirror, based onto a spherical mirror and a dedicated CGH. The spherical beam of the interferometer is quasi collimated to the desired diameter by the spherical mirror, used slightly off-axis, and the CGH performs the residual wavefront correction. We performed tests on a 200 mm and 300 mm flat mirrors, and compared the results to the ones obtained by stitching, showing an accuracy well within the designed value. The possibility to calibrate the cavity by subtracting out the figure errors of the spherical mirror has also been evaluated.
Method for Cleanly and Precisely Breaking Off a Rock Core Using a Radial Compressive Force
NASA Technical Reports Server (NTRS)
Richardson, Megan; Lin, Justin
2011-01-01
The Mars Sample Return mission has the goal to drill, break off, and retain rock core samples. After some results gained from rock core mechanics testing, the realization that scoring teeth would cleanly break off the core after only a few millimeters of penetration, and noting that rocks are weak in tension, the idea was developed to use symmetric wedging teeth in compression to weaken and then break the core at the contact plane. This concept was developed as a response to the break-off and retention requirements. The wedges wrap around the estimated average diameter of the core to get as many contact locations as possible, and are then pushed inward, radially, through the core towards one another. This starts a crack and begins to apply opposing forces inside the core to propagate the crack across the plane of contact. The advantage is in the simplicity. Only two teeth are needed to break five varieties of Mars-like rock cores with limited penetration and reasonable forces. Its major advantage is that it does not require any length of rock to be attached to the parent in order to break the core at the desired location. Test data shows that some rocks break off on their own into segments or break off into discs. This idea would grab and retain a disc, push some discs upward and others out, or grab a segment, break it at the contact plane, and retain the portion inside of the device. It also does this with few moving parts in a simple, space-efficient design. This discovery could be implemented into a coring drill bit to precisely break off and retain any size rock core.
NASA Technical Reports Server (NTRS)
Seo, Byoung-Joon; Nissly, Carl; Troy, Mitchell; Angeli, George
2010-01-01
The Normalized Point Source Sensitivity (PSSN) has previously been defined and analyzed as an On-Axis seeing-limited telescope performance metric. In this paper, we expand the scope of the PSSN definition to include Off-Axis field of view (FoV) points and apply this generalized metric for performance evaluation of the Thirty Meter Telescope (TMT). We first propose various possible choices for the PSSN definition and select one as our baseline. We show that our baseline metric has useful properties including the multiplicative feature even when considering Off-Axis FoV points, which has proven to be useful for optimizing the telescope error budget. Various TMT optical errors are considered for the performance evaluation including segment alignment and phasing, segment surface figures, temperature, and gravity, whose On-Axis PSSN values have previously been published by our group.
Ziegler, Raphaela; Goebel, Lars; Cucchiarini, Magali; Pape, Dietrich; Madry, Henning
2014-07-01
To evaluate whether medial open wedge high tibial osteotomy (HTO) results in structural changes in the articular cartilage in the lateral tibiofemoral compartment of adult sheep. Three experimental groups received biplanar osteotomies of the right proximal tibiae: (a) closing wedge HTO (4.5° of tibial varus), (b) opening wedge HTO (4.5° tibial valgus; standard correction), and (c) opening wedge HTO (9.5° of valgus; overcorrection), each of which was compared to the contralateral knees that only received an arthrotomy. After 6 months, the macroscopic and microscopic characteristics of the articular cartilage of the lateral tibiofemoral compartment were assessed. The articular cartilage in the central region of the lateral tibial plateau in sheep had a higher safranin O staining intensity and was 4.6-fold thicker than in the periphery (covered by the lateral meniscus). No topographical variation in the type-II collagen immunoreactivity was seen. All lateral tibial plateaus showed osteoarthritic changes in regions not covered by the lateral meniscus. No osteoarthritis was seen in the peripheral submeniscal regions of the lateral tibial plateau and the lateral femoral condyle. Opening wedge HTO resulting in both standard and overcorrection was not associated with significant macroscopic and microscopic structural changes between groups in the articular cartilage of the lateral tibial plateau and femoral condyle after 6 months in vivo. Opening wedge HTO resulting in both standard and overcorrection is a safe procedure for the articular cartilage in an intact lateral tibiofemoral compartment of adult sheep at 6 months postoperatively.
Deep Broad-Band Infrared Nulling Using A Single-Mode Fiber Beam Combiner and Baseline Rotation
NASA Technical Reports Server (NTRS)
Mennesson, Bertrand; Haguenauer, P.; Serabyn, E.; Liewer, K.
2006-01-01
The basic advantage of single-mode fibers for deep nulling applications resides in their spatial filtering ability, and has now long been known. However, and as suggested more recently, a single-mode fiber can also be used for direct coherent recombination of spatially separated beams, i.e. in a 'multi-axial' nulling scheme. After the first successful demonstration of deep (<2e-6) visible LASER nulls using this technique (Haguenauer & Serabyn, Applied Optics 2006), we decided to work on an infrared extension for ground based astronomical observations, e.g. using two or more off-axis sub-apertures of a large ground based telescope. In preparation for such a system, we built and tested a laboratory infrared fiber nuller working in a wavelength regime where atmospheric turbulence can be efficiently corrected, over a pass band (approx.1.5 to 1.8 micron) broad enough to provide reasonable sensitivity. In addition, since no snapshot images are readily accessible with a (single) fiber nuller, we also tested baseline rotation as an approach to detect off-axis companions while keeping a central null. This modulation technique is identical to the baseline rotation envisioned for the TPF-I space mission. Within this context, we report here on early laboratory results showing deep stable broad-band dual polarization infrared nulls <5e-4 (currently limited by detector noise), and visible LASER nulls better than 3e-4 over a 360 degree rotation of the baseline. While further work will take place in the laboratory to achieve deeper stable broad-band nulls and test off-axis sources detection through rotation, the emphasis will be put on bringing such a system to a telescope as soon as possible. Detection capability at the 500:1 contrast ratio in the K band (2.2 microns) seem readily accessible within 50-100 mas of the optical axis, even with a first generation system mounted on a >5m AO equipped telescope such as the Palomar Hale 200 inch, the Keck, Subaru or Gemini telescopes.
Optomechanical design of near-null subaperture test system based on counter-rotating CGH plates
NASA Astrophysics Data System (ADS)
Li, Yepeng; Chen, Shanyong; Song, Bing; Li, Shengyi
2014-09-01
In off-axis subapertures of most convex aspheres, astigmatism and coma dominate the aberrations with approximately quadratic and linear increase as the off-axis distance increases. A pair of counter-rotating computer generated hologram (CGH) plates is proposed to generate variable amount of Zernike terms Z4 and Z6, correcting most of the astigmatism and coma for subapertures located at different positions on surfaces of various aspheric shapes. The residual subaperture aberrations are then reduced within the vertical range of measurement of the interferometer, which enables near-null test of aspheres flexibly. The alignment tolerances for the near-null optics are given with optomechanical analysis. Accordingly a novel design for mounting and aligning the CGH plates is proposed which employs three concentric rigid rings. The CGH plate is mounted in the inner ring which is supported by two couples of ball-end screws in connection with the middle ring. The CGH plate along with the inner ring is hence able to be translated in X-axis and tipped by adjusting the screws. Similarly the middle ring is able to be translated in Y-axis and tilted by another two couples of screws orthogonally arranged and connected to the outer ring. This design is featured by the large center-through hole, compact size and capability of four degrees-of-freedom alignment (lateral shift and tip-tilt). It reduces the height measured in the direction of optical axis as much as possible, which is particularly advantageous for near-null test of convex aspheres. The CGH mounts are then mounted on a pair of center-through tables realizing counter-rotation. Alignment of the interferometer, the CGHs, the tables and the test surface is also discussed with a reasonable layout of the whole test system. The interferometer and the near-null optics are translated by a three-axis stage while the test mirror is rotated and tilted by two rotary tables. Experimental results are finally given to show the near-null subaperture test capability of the system for a convex even asphere.
Far-ultraviolet observations of comet C/2012 S1 (ISON) with a sounding-rocket-borne instrument
NASA Astrophysics Data System (ADS)
Feldman, P.; McCandliss, S.; Weaver, H.; Fleming, B.; Redwine, K.; Li, M.; Kutyrev, A.; Moseley, S.
2014-07-01
We report on a far-ultraviolet observation of comet C/2012 S1 (ISON) made from a Black Brant IX sounding rocket that was launched on 20 November 2013 at 04:40 MST from the White Sands Missile Range, New Mexico, when the comet was 0.44 au from the Sun, 0.86 au from the Earth, and at a solar elongation of 26.3 degrees pre-perihelion. At the time of launch the comet was 0.1 degrees below ground horizon. The payload reached an apogee of 279 km and the total time pointed at the comet was 353 s. The sounding rocket borne instrument was our wide-field multi-object spectro-telescope called FORTIS (Far-UV Off Rowland-circle Telescope for Imaging and Spectroscopy), which is a Gregorian telescope (concave primary and secondary optics) with a triaxial figured diffractive secondary that provides an on-axis imaging channel and two off-axis spectral channels in a common focal plane. A multi-object spectroscopic capability is provided by an array of microshutters placed at the prime focus of the telescope. Our microshutter array (MSA) is based on prototype devices of the large area arrays developed at Goddard Space Flight Center (GSFC) for use in the Near Infrared Spectrograph (NIRSpec) on the James Webb Space Telescope (JWST). The imaging channel on FORTIS has a field-of-view (FOV) of 0.5 degrees square. The MSA allows selection of up to 43 individual regions, each with a solid angle of 12.4'' × 36.9'', for spectral acquisition over the 800--1950 Ångstroms bandpass at a resolution of 6 Ångstroms. However a problem with addressing the MSA prevented the acquisition of spectra through individual slits. Nonetheless spectrally confused images, dominated by Lyman-alpha emission from the comet, were acquired in both off-axis spectral channels. The imaging channel uses a CaF_2/MgF_2 cylindrical doublet to correct for astigmatism introduced by the triaxial secondary, which restricts the bandpass to wavelengths longward of 1280 Ångstroms. The corrected imaging resolution is approximately 4''. Broadband images of the comet acquired in the on-axis imaging channel throughout the duration of the flight show a variation in count rate proportional to altitude due to absorption of cometary emissions by terrestrial molecular oxygen located in the lower thermosphere. Molecular oxygen absorption has a strong dependence on wavelength, which will selectively attenuate cometary emissions from different atomic and molecular species and allow us to constrain their production rates relative to hydrogen observed in the spectral channels. Analysis is ongoing and preliminary results will be presented.
Influence of stress interaction on the behavior of off-axis unidirectional composites
NASA Technical Reports Server (NTRS)
Pindera, M. J.; Herakovich, C. T.
1980-01-01
The yield function for plane stress of a transversely isotropic composite lamina consisting of stiff, linearly elastic fibers and a von Mises matrix material is formulated in terms of Hill's elastic stress concentration factors and a single plastic constraint parameter. The above are subsequently evaluated on the basis of observed average lamina and constituent response for the Avco 5505 boron epoxy system. It is shown that inclusion of residual stresses in the yield function together with the incorporation of Dubey and Hillier's concept of generalized yield stress for anisotropic media in the constitutive equation correctly predicts the trends observed in experiments. The incorporation of the strong axial stress interaction necessary to predict the correct trends in the shear response is directly traced to the high residual axial stresses in the matrix induced during fabrication of the composite.
Effect of Off-Axis Screw Insertion, Insertion Torque, and Plate Contouring on Locked Screw Strength
Gallagher, Bethany; Silva, Matthew J.; Ricci, William M.
2015-01-01
Objectives This study quantifies the effects of insertion torque, off-axis screw angulation, and plate contouring on the strength of locking plate constructs. Methods Groups of locking screws (n = 6–11 screws) were inserted at 50%, 100%, 150%, and 200% of the manufacturer-recommended torque (3.2 Nm) into locking compression plates at various angles: orthogonal (control), 5-degree angle off-axis, and 10-degree angle off-axis. Screws were loaded to failure by a transverse force (parallel to the plate) either in the same (“+”) or opposite direction (“−”) of the initial screw angulation. Separately, locking plates were bent to 5 and 10-degree angles, with the bend apex at a screw hole. Locking screws inserted orthogonally into the apex hole at 100% torque were loaded to failure. Results Orthogonal insertion resulted in the highest average load to failure, 2577 ± 141 N (range, 2413–2778 N), whereas any off-axis insertion significantly weakened constructs (165–1285 N, at 100% torque) (P < 0.05). For “+” loading, torque beyond 100% did not increase strength, but 50% torque reduced screw strength (P < 0.05). Loading in the “−” direction consistently resulted in higher strengths than “+” loading (P < 0.05). Plate contouring of 5-degree angle did not significantly change screw strength compared with straight plates but contouring of 10-degree angle significantly reduced load to failure (P < 0.05). Conclusions To maximize the screw plate interface strength, locking screws should be inserted without cross-threading. The mechanical stability of locked screws is significantly compromised by loose insertion, off-axis insertion, or severe distortion of the locking mechanism. PMID:24343255
Quaternary Sedimentary Processes and Budgets in Orphan Basin, Southwestern Labrador Sea
NASA Astrophysics Data System (ADS)
Hiscott, Richard N.; Aksu, Ali E.
1996-03-01
The continental slope in Orphan Basin, northeast of Newfoundland, is underlain by several seaward-thinning debris-flow wedges alternating with acoustically stratified, regionally extensive, mainly hemipelagic sediments. δ 18O stratigraphy and volcanic ash layers in a 11.67-m core indicate that the uppermost debris-flow wedge formed during the last of several sea-level lowstands in isotopic stages 2-4. Similarly, seismic reflection correlation of dated levels at DSDP Site 111 with the Orphan Basin succession suggests that two deeper debris-flow wedges were deposited during oxygen isotopic stages 6 and 8. The oldest of the debris-flow deposits in at least three of the wedges formed well into the corresponding glacial cycle, after ice sheets had reached the edge of the continental shelf. Slower deposition by hemipelagic processes and ice rafting formed the acoustically stratified units, including Heinrich layers. The youngest three debris-flow wedges each have volumes of 1300-1650 km 3. Approximately two-thirds of this material is attributed to glacial erosion of Mesozoic and Tertiary strata beneath the Northeast Newfoundland Shelf. The remainder is believed to have been derived by glacial erosion of older bedrock that now forms the island of Newfoundland. The observed sediment volumes and the inferred basal and upper ages of the debris-flow wedges imply an average glacial denudation rate of about 0.13 mm/yr for this older bedrock, and an average of about 60 m of glacial bedrock erosion since oxygen isotope stage 22. This denudation rate is similar to estimates from the Barents Sea region off Norway.
RANS Analyses of Turbofan Nozzles with Wedge Deflectors for Noise Reduction
NASA Technical Reports Server (NTRS)
DeBonis, James R.
2008-01-01
Computational fluid dynamics (CFD) was used to evaluate a promising concept for reducing the noise at take-off of dual-stream, turbofan nozzles. The concept, offset stream technology, reduces the jet noise observed on the ground by diverting (offsetting) the majority of the fan flow below the core flow, thickening this layer between the high velocity core flow and the ground observers. In this study a wedge placed in the internal fan stream is used as the diverter. Wind, a Reynolds Averaged Navier-Stokes (RANS) code, was used to analyze the flowfield of the exhaust plume and to calculate nozzle performance. Results showed that the wedge effectively diverts the fan flow and the turbulent kinetic energy on the observer side of the nozzle is reduced. The reduction in turbulent kinetic energy should correspond to a reduction in noise. The blockage due to the wedge reduces the fan massflow proportional to its blockage and the overall thrust is consequently reduced. The CFD predictions are in very good agreement with experimental data. This noise reduction concept shows promise for reduced jet noise at a small reduction in thrust. It has been demonstrated that RANS CFD can be used to optimize this concept.
SU-F-T-425: Head-Scatter Off-Axis for FFF Megavoltage Photon Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, T; Penjweini, R; Dimofte, A
Purpose: Head-scatter photons inside a clinical accelerator cause the output to change with collimator setting. On the central-axis, this contribution is well-described by output factor in air (or head-scatter factor). However, a few studies have examined this component at off-axis points. Methods: We define the head-scatter off-axis ratio, HOA, as the ratio of the water kerma in air due to head-scatter photons at the off-axis position x to the water kerma from direct primary photons on the central axis: HOA(cx,cy,xy) = (Q(cx,cy,x) – QP(cx,cy,x))/QP(cx,cy,0), where Q(cx, cy,x), QP(cx,cy,x) are charges measured by an ionization chamber in a miniphantom for collimatormore » setting cx × cy and cx × 3 cm, respectively, at off-axis point x. “Direct primary” is those photons that come from the source without interactions in the intervening structures. Results: We measured HOA for two energies (6XFFF and 6X) along X and Y jaw directions for various collimator settings. The shape of HOA has well defined penumbra for collimator setting larger than 10 × 10 cm2. Conclusion: The narrow gaussian component is interpreted as the source of photons scattered in the flattening filter and the primary collimator. The broad component is attributed to photons scattered in the secondary (variable) collimators. By a direct comparison between 6X and 6XFFF beams, we can confirm that the second component is indeed coming from collimator jaws and identify the parts coming from the primary collimator and the flattening filter, respectively.« less
Wang, Joon Ho; Shin, Jung Min; Kim, Hyun Ho; Kang, Seung-Hoon; Lee, Byung Hoon
2017-01-01
To evaluate the differences in the amount of varus malalignment and valgus (over) correction in relation to three different weight bearing conditions from whole leg AP radiographs (single-limb (SL) stance, double-limb (DL) stance, supine position (S)) before and after high tibial osteotomy (HTO), and to evaluate which alignment parameters affect the changes for patients in three different weight bearing conditions. A total of 40 consecutive patients (43 knees) with varus osteoarthritis underwent navigation assisted open wedge HTO. Mechanical axis angle (MA) was measured before and after surgery from hip-to-ankle radiographs taken with patients in three different weight bearing conditions. To find significant factors that affect the alignment differences, several variables including patient demographics, soft tissue laxity, pelvic obliquity, and ground mechanical axis deviation of tibia (calculated by the angle between two lines, tibial anatomical axis and weight-bearing line) were evaluated. Pre-operatively, mean MA measured on SL stance radiographs was significantly more varus than on DL stance (10.1° ± 2.4° and 8.0° ± 2.6°, respectively, p < 0.001), which was significantly more varus than on supine position (6.6° ± 2.6°, p < 0.001). Meanwhile, in patients with post-operatively valgus corrected knee, MA did not show the same pattern of change as with pre-operative varus knee. Mean MA measured on DL stance radiographs was more valgus than in supine position (-3.0 o ± 2.4 o and -2.6 o ± 3.1 o , p = 0.455), while mean MA on SL stance radiographs (-2.0 o ± 2.1 o ) was significantly less valgus than on DL stance (p = 0.002). The ground mechanical axis deviation of tibia showed a significant correlation with MA difference between SL and DL stance radiographs before (β = -0.341, p = 0.045) and after surgery (β = -0.536, p = 0.001). In pre-operative varus knee, the mean MA on SL stance was changed to more varus than on DL stance, which changed to less valgus in post-operative valgus knee. The understanding in discrepancy of alignment in different weight bearing conditions before and after HTO should be considered for the appropriate realignment of the limb. Level II Prospective comparative study.
Chen, Jianjun; Cui, Jicheng; Yao, Xuefeng; Liu, Jianan; Sun, Ci
2018-04-01
To solve the problem where the actual grating aperture decreases with an increasing scanning angle during the scanning of a three-grating monochromator, we propose an off-axis assembly method for the worm gear turntable that makes it possible to suppress this aperture reduction. We simulated and compared the traditional assembly method with the off-axis assembly method in the three-grating monochromator. Results show that the actual grating aperture can be improved by the off-axis assembly method. In fact, for any one of the three gratings, when the monochromator outputs the longest wavelength in the corresponding wavelength band, the actual grating aperture increases by 45.93%. Over the entire monochromator output band, the actual grating aperture increased by an average of 32.56% and can thus improve the monochromator's output energy. Improvement of the actual grating aperture can also reduce the stray light intensity in the monochromator and improve its output signal-to-noise ratio.
Off-axis mirror fabrication from spherical surfaces under mechanical stress
NASA Astrophysics Data System (ADS)
Izazaga-Pérez, R.; Aguirre-Aguirre, D.; Percino-Zacarías, M. E.; Granados-Agustín, Fermin-Salomon
2013-09-01
The preliminary results in the fabrication of off-axis optical surfaces are presented. The propose using the conventional polishing method and with the surface under mechanical stress at its edges. It starts fabricating a spherical surface using ZERODUR® optical glass with the conventional polishing method, the surface is deformed by applying tension and/or compression at the surface edges using a specially designed mechanical mount. To know the necessary deformation, the interferogram of the deformed surface is analyzed in real time with a ZYGO® Mark II Fizeau type interferometer, the mechanical stress is applied until obtain the inverse interferogram associated to the off-axis surface that we need to fabricate. Polishing process is carried out again until obtain a spherical surface, then mechanical stress in the edges are removed and compares the actual interferogram with the theoretical associated to the off-axis surface. To analyze the resulting interferograms of the surface we used the phase shifting analysis method by using a piezoelectric phase-shifter and Durango® interferometry software from Diffraction International™.
Imaging characteristics of the Extreme Ultraviolet Explorer microchannel plate detectors
NASA Technical Reports Server (NTRS)
Vallerga, J. V.; Kaplan, G. C.; Siegmund, O. H. W.; Lampton, M.; Malina, R. F.
1989-01-01
The Extreme Ultraviolet Explorer (EUVE) satellite will conduct an all-sky survey over the wavelength range from 70 A to 760 A using four grazing-incidence telescopes and seven microchannel-plate (MCP) detectors. The imaging photon-counting MCP detectors have active areas of 19.6 cm2. Photon arrival position is determined using a wedge-and-strip anode and associated pulse-encoding electronics. The imaging characteristics of the EUVE flight detectors are presented including image distortion, flat-field response, and spatial differential nonlinearity. Also included is a detailed discussion of image distortions due to the detector mechanical assembly, the wedge-and-strip anode, and the electronics. Model predictions of these distortions are compared to preflight calibration images which show distortions less than 1.3 percent rms of the detector diameter of 50 mm before correction. The plans for correcting these residual detector image distortions to less than 0.1 percent rms are also presented.
Analysis of off-axis incoherent digital holographic microscopy
NASA Astrophysics Data System (ADS)
Quan, Xiangyu; Matoba, Osamu; Awatsuji, Yasuhiro
2017-05-01
Off-axis incoherent digital holography that enables single-shot three-dimensional (3D) distribution is introduced in the paper. Conventional fluorescence microscopy images 3D fields by sectioning, this prevents instant imaging of fast reactions of living cells. In order to realize digital holography from incoherent light, we adapted common path configuration to achieve the best temporal coherence. And by introducing gratings, we shifted the direction of each light to achieve off-axis interference. Simulations and preliminary experiments using LED light have confirmed the results. We expect to use this method to realize 3D phase imaging and fluorescent imaging at the same time from the same biological sample.
Calculating broad neutron resonances in a cut-off Woods-Saxon potential
NASA Astrophysics Data System (ADS)
Baran, Á.; Noszály, Cs.; Salamon, P.; Vertse, T.
2015-07-01
In a cut-off Woods-Saxon (CWS) potential with realistic depth S -matrix poles being far from the imaginary wave number axis form a sequence where the distances of the consecutive resonances are inversely proportional with the cut-off radius value, which is an unphysical parameter. Other poles lying closer to the imaginary wave number axis might have trajectories with irregular shapes as the depth of the potential increases. Poles being close repel each other, and their repulsion is responsible for the changes of the directions of the corresponding trajectories. The repulsion might cause that certain resonances become antibound and later resonances again when they collide on the imaginary axis. The interaction is extremely sensitive to the cut-off radius value, which is an apparent handicap of the CWS potential.
NASA Astrophysics Data System (ADS)
Liu, Xin; Zhao, Dapeng
2016-10-01
We present the first high-resolution Rayleigh-wave phase-velocity azimuthal anisotropy tomography of the Japan subduction zone at periods of 20-150 s, which is determined using a large number of high-quality amplitude and phase data of teleseismic fundamental-mode Rayleigh waves. The obtained 2-D anisotropic phase-velocity models are then inverted for a 3-D shear-wave velocity azimuthal anisotropy tomography down to a depth of ˜300 km beneath Japan. The subducting Pacific slab is imaged as a dipping high-velocity zone with trench-parallel fast-velocity directions (FVDs) which may indicate the anisotropy arising from the normal faults produced at the outer-rise area near the Japan trench axis, overprinting the slab fossil fabric, whereas the mantle wedge generally exhibits lower velocities with trench-normal FVDs which reflect subduction-driven corner flow and anisotropy. Depth variations of azimuthal anisotropy are revealed in the big mantle wedge beneath the Japan Sea, which may reflect past deformations in the Eurasian lithosphere related to backarc spreading during 21 to 15 Ma and complex current convection in the asthenosphere induced by active subductions of both the Pacific and Philippine Sea plates.
Episodic plate separation and fracture infill on the surface of Europa. Galileo Imaging Team.
Sullivan, R; Greeley, R; Homan, K; Klemaszewski, J; Belton, M J; Carr, M H; Chapman, C R; Tufts, R; Head, J W; Pappalardo, R; Moore, J; Thomas, P
1998-01-22
Images obtained by the Voyager spacecraft revealed dark, wedge-shaped bands on Europa that were interpreted as evidence that surface plates, 50-100 km across, moved and rotated relative to each other. This implied that they may be mechanically decoupled from the interior by a layer of warm ice or liquid water. Here we report similar features seen in higher resolution images (420 metres per pixel) obtained by the Galileo spacecraft that reveal new details of wedge-band formation. In particular, the interior of one dark band shows bilateral symmetry of parallel lineaments and pit complexes which indicates that plate separation occurred in discrete episodes from a central axis. The images also show that this style of tectonic activity involved plates < 10 km across. Although this tectonic style superficially resembles aspects of similar activity on Earth, such as sea-floor spreading and the formation of ice leads in polar seas, there are significant differences in the underlying physical mechanisms: the wedge-shaped bands on Europa most probably formed when lower material (ice or water) rose to fill the fractures that widened in response to regional surface stresses.
Validation of the BASALT model for simulating off-axis hydrothermal circulation in oceanic crust
NASA Astrophysics Data System (ADS)
Farahat, Navah X.; Archer, David; Abbot, Dorian S.
2017-08-01
Fluid recharge and discharge between the deep ocean and the porous upper layer of off-axis oceanic crust tends to concentrate in small volumes of rock, such as seamounts and fractures, that are unimpeded by low-permeability sediments. Basement structure, sediment burial, heat flow, and other regional characteristics of off-axis hydrothermal systems appear to produce considerable diversity of circulation behaviors. Circulation of seawater and seawater-derived fluids controls the extent of fluid-rock interaction, resulting in significant geochemical impacts. However, the primary regional characteristics that control how seawater is distributed within upper oceanic crust are still poorly understood. In this paper we present the details of the two-dimensional (2-D) BASALT (Basement Activity Simulated At Low Temperatures) numerical model of heat and fluid transport in an off-axis hydrothermal system. This model is designed to simulate a wide range of conditions in order to explore the dominant controls on circulation. We validate the BASALT model's ability to reproduce observations by configuring it to represent a thoroughly studied transect of the Juan de Fuca Ridge eastern flank. The results demonstrate that including series of narrow, ridge-parallel fractures as subgrid features produces a realistic circulation scenario at the validation site. In future projects, a full reactive transport version of the validated BASALT model will be used to explore geochemical fluxes in a variety of off-axis hydrothermal environments.
NASA Astrophysics Data System (ADS)
Joseph, Jobin; Külls, Christoph
2014-05-01
The δ13C and δ18O of CO2 has enormous potential as tracers to study and quantify the interaction between the water and carbon cycles. Isotope ratio mass spectrometry (IRMS) being the conventional method for stable isotopic measurements, has many limitations making it impossible for deploying them in remote areas for online or in-situ sampling. New laser based absorption spectroscopy approaches like Cavity Ring Down Spectroscopy (CRDS) and Integrated Cavity Output Spectroscopy (ICOS) have been developed for online measurements of stable isotopes at an expense of considerably less power requirement but with precision comparable to IRMS. In this research project, we introduce a new calibration system for an Off- Axis ICOS (Los Gatos Research CCIA-36d) for a wide range of varying concentrations of CO2 (800ppm - 25,000ppm), a typical CO2 flux range at the plant-soil continuum. The calibration compensates for the concentration dependency of δ13C and δ18O measurements, and was performed using various CO2 standards with known CO2 concentration and δC13 and δO18 values. A mathematical model was developed after the calibration procedure as a correction factor for the concentration dependency of δ13C and δ18O measurements. Temperature dependency of δ13C and δ18O measurements were investigated and no significant influence was found. Simultaneous calibration of δ13C and δ18O is achieved using this calibration system with an overall accuracy of (~ 0.75±0.24 ‰ for δ13C, ~ 0.81 ±0.26‰ for δ18O). This calibration procedure is found to be appropriate for making Off-Axis ICOS suitable for measuring CO2 concentration and δ13C and δ18O measurements at atmosphere-plant-soil continuum.
Prompt and Afterglow Emission from Short GRB Cocoons
NASA Astrophysics Data System (ADS)
Morsony, Brian; Lazzati, Davide; López-Cámara, Diego; Workman, Jared; Moskal, Jeremiah; Cantiello, Matteo; Perna, Rosalba
2018-01-01
We present simulations of short GRB jets that create a wide cocoon of mildly relativistic material surrounding the narrow, highly relativistic jet. We model the prompt and afterglow emission from the jet and cocoon at a range of observer angles relative to the jet axis. Even far off axis, prompt X-ray and gamma-ray emission from the cocoon may be detectable by FERMI GBM out to several 10’s of Mpc. Afterglow emission off-axis is dominated by cocoon material at early times (hours - days). The afterglow should be detectable at a wide range of frequencies (radio, optical, X-ray) for a large fraction of off-axis short GRBs within 200 Mpc, the detection range of aLIGO at design sensitivity. Given recent events, cocoon emission may be very important in the future for localizing LIGO-detected neutron star mergers.
Multi-Axis Thrust Measurements of the EO-1 Pulsed Plasma Thruster
NASA Technical Reports Server (NTRS)
Arrington, Lynn A.; Haag, Thomas W.
1999-01-01
Pulsed plasma thrusters are low thrust propulsive devices which have a high specific impulse at low power. A pulsed plasma thruster is currently scheduled to fly as an experiment on NASA's Earth Observing-1 satellite mission. The pulsed plasma thruster will be used to replace one of the reaction wheels. As part of the qualification testing of the thruster it is necessary to determine the nominal thrust as a function of charge energy. These data will be used to determine control algorithms. Testing was first completed on a breadboard pulsed plasma thruster to determine nominal or primary axis thrust and associated propellant mass consumption as a function of energy and then later to determine if any significant off-axis thrust component existed. On conclusion that there was a significant off-axis thrust component with the bread-board in the direction of the anode electrode, the test matrix was expanded on the flight hardware to include thrust measurements along all three orthogonal axes. Similar off-axis components were found with the flight unit.
Liang, Yan; Tang, Xiangyu; Zhao, Yongfei; Wang, Zheng
2017-03-31
Andersson lesion is a well-known complication in ankylosing spondylitis. Recently, owing to the worry about the healing of fracture, some scholars advocated additional anterior surgery or other procedures were necessary, which increase the risk of the nerve injury. The purpose of this study is to introduce our experience and to explore the efficacy and feasibility of posterior wedge osteotomy and debridement through Andersson Lesion for surgical treatment of severe kyphosis in ankylosing spondylitis. From January 2012 to January 2014, a retrospective study of 14 Andersson lesion patients with severe kyphosis in ankylosing spondylitis treated with surgery was completed with an at least 2-year follow-up. The debridement procedure, before posterior wedge osteotomy in posterior approach, must scrape all sclerosis bone until healthy cancellous bone appears. Radiographic and clinical results and complications were assessed with an average follow-up of 24 months. The CT scan was obtained preoperatively and at the final follow-up to assess the displacement of the fracture preoperatively, the safety of screw insertion, the healing of the fracture at the final follow-up. The Bridwell interbody fusion grading system was used to assess the healing of the fracture. Local kyphosis was substantially corrected from 51.7 ± 15.6 to 7.1 ± 19.5, with a mean correction of 44°. The global kyphosis (GK) changed from 60.6 ± 28.3 to 20.3 ± 10.3 (P = 0.000). The mean VAS back pain scores decreased from 6.7 ± 0.8 preoperatively to 0.75 ± 0.6 after a 2-year follow-up (P = 0.000). The ODI score improved from 60.56 ± 15.1% preoperatively to 23.46 ± 8.2% after a 2-year follow-up (P = 0.000). The CT scan showed solid fusion at the level of the AL, and no internal fixation loose. All patients achieved grade 1 fusion. No major complication occurred. The posterior wedge osteotomy and debridement through AL can be used to correct the severe kyphosis in ankylosing spondylitis, achieving favorable clinical outcomes, good fusion, and satisfactory deformity correction.
2007-05-01
general, off axis imaging can cause distortion and astigmatism in the image if proper precautions are not taken. In this case, the lens selection... astigmatism into the optical system. This astigmatism takes the form of a blurring in each image directed away from the optical axis. This blurring...is non-trivial and makes particle identification nearly impossible. Images of particles from two of the off axis cameras with the astigmatism present
Analysis and design of wedge projection display system based on ray retracing method.
Lee, Chang-Kun; Lee, Taewon; Sung, Hyunsik; Min, Sung-Wook
2013-06-10
A design method for the wedge projection display system based on the ray retracing method is proposed. To analyze the principle of image formation on the inclined surface of the wedge-shaped waveguide, the bundle of rays is retraced from an imaging point on the inclined surface to the aperture of the waveguide. In consequence of ray retracing, we obtain the incident conditions of the ray, such as the position and the angle at the aperture, which provide clues for image formation. To illuminate the image formation, the concept of the equivalent imaging point is proposed, which is the intersection where the incident rays are extended over the space regardless of the refraction and reflection in the waveguide. Since the initial value of the rays arriving at the equivalent imaging point corresponds to that of the rays converging into the imaging point on the inclined surface, the image formation can be visualized by calculating the equivalent imaging point over the entire inclined surface. Then, we can find image characteristics, such as their size and position, and their degree of blur--by analyzing the distribution of the equivalent imaging point--and design the optimized wedge projection system by attaching the prism structure at the aperture. The simulation results show the feasibility of the ray retracing analysis and characterize the numerical relation between the waveguide parameters and the aperture structure for on-axis configuration. The experimental results verify the designed system based on the proposed method.
NASA Astrophysics Data System (ADS)
Briais, Anne; Barrère, Fabienne; Boulart, Cédric; Ceuleneer, Georges; Ferreira, Nicolas; Hanan, Barry; Hémond, Christophe; Macleod, Sarah; Maia, Marcia; Maillard, Agnès; Merkuryev, Sergey; Park, Sung-Hyun; Révillon, Sidonie; Ruellan, Etienne; Schohn, Alexandre; Watson, Sally; Yang, Yun-Seok
2016-04-01
We present observations of the South-East Indian Ridge (SEIR) collected during the STORM cruise (South Tasmania Ocean Ridge and Mantle) on the N/O L'Atalante early 2015. The SEIR between Australia and Antarctica displays large variations of axial morphology despite an almost constant intermediate spreading rate. The Australia-Antarctic Discordance (AAD) between 120°E and 128°E is a section of the mid-ocean ridge where the magma budget is abnormally low, and which marks the boundary between Indian and Pacific mantle domains with distinct geochemical isotopic compositions. The STORM project focuses on the area east of the discordance from 128 to 140°E, where gravity highs observed on satellite-derived maps of the flanks of the SEIR reveal numerous volcanic seamounts. A major objective of the STORM cruise was to test the hypothesis of a mantle flow from the Pacific to the Indian domains. We collected multibeam bathymetry and magnetic data between 136 and 138°E to map off-axis volcanic ridges up to 10 Ma-old crust. We mapped the SEIR axis between 129 and 140°E, and the northern part of the George V transform fault. We collected rock samples on seamounts and in the transform fault, basaltic glass samples along the ridge axis, and near-bottom samples and in-situ measurements in the water column. Our observations reveal that the off-axis seamounts form near the SEIR axis, are not associated to off-axis deformation of the ocean floor, and are often located near the traces of ridge axis discontinuities. We also observe a general shallowing of the ridge axis from the AAD to the George V TF and the presence of robust axial segments near the transform fault. Our new data allow us to describe the complex evolution of the transform fault system. They also permit to locate new hydrothermal systems along the ridge axis.
A method of solving tilt illumination for multiple distance phase retrieval
NASA Astrophysics Data System (ADS)
Guo, Cheng; Li, Qiang; Tan, Jiubin; Liu, Shutian; Liu, Zhengjun
2018-07-01
Multiple distance phase retrieval is a technique of using a series of intensity patterns to reconstruct a complex-valued image of object. However, tilt illumination originating from the off-axis displacement of incident light significantly impairs its imaging quality. To eliminate this affection, we use cross-correlation calibration to estimate oblique angle of incident light and a Fourier-based strategy to correct tilted illumination effect. Compared to other methods, binary and biological object are both stably reconstructed in simulation and experiment. This work provides a simple but beneficial method to solve the problem of tilt illumination for lens-free multi-distance system.
Paddick, Stella-Maria; Mkenda, Sarah; Mbowe, Godfrey; Kisoli, Aloyce; Gray, William K; Dotchin, Catherine L; Ternent, Laura; Ogunniyi, Adesola; Kissima, John; Olakehinde, Olaide; Mushi, Declare; Walker, Richard W
2017-06-01
In the above article (Paddick, 2017) The corresponding author's details were previously listed incorrectly. The correct details are; contact number +44 191 293 2709 and email address William.gray@nhct.nhs.uk. The original article has been updated with the correct contact details. The publishers apologise for any inconvenience and confusion this error has caused.
Aerodynamics of Supersonic Lifting Bodies
1981-02-01
Correction Velocity Ratio, y = 1.4 .. ......... . . . . 38 9 Perturbation Pressure Coefficient on the Body Surface .... 41 10 Pressure Coefficient on...Secant Method and Exper.1ent ... ....... 119 40 Geometrica . :onfinmration anl 7ro)r;1Tnate Systens ....... 125 41 1pheri. •a. 1-rinites...due to pitching p contribution due to plunging 8 shock wave w wedge z contribution due to pitching about Ln 0 free stream Superscripts (c) correction
Refraction and scattering of sound by a shear layer
NASA Technical Reports Server (NTRS)
Schlinker, R. H.; Amiet, R. K.
1980-01-01
The angle and amplitude changes for acoustic waves refracted by a circular open jet shear layer were determined. The generalized refraction theory was assessed experimentally for on axis and off axis acoustic source locations as source frequency varied from 1 kHz to 10 kHz and free stream Mach number varied from 0.1 to 0.4. Angle and amplitude changes across the shear layer show good agreement with theory. Experiments confirm that the refraction theory is independent of shear layer thickness, acoustic source frequency, and source type. A generalized theory is, thus, available for correcting far field noise data acquired in open jet test facilities. The effect of discrete tone scattering by the open jet turbulent shear layer was also studied. Scattering effects were investigated over the same Mach number range as frequency varied from 5 kHz to 15 kHz. Attenuation of discrete tone amplitude and tone broadening were measured as a function of acoustic source position and radiation angle. Scattering was found to be stronger at angles close to the open jet axis than at 90 deg, and becomes stronger as the acoustic source position shifts downstream. A scattering analysis provided an estimate of the onset of discrete tone scattering.
NASA Technical Reports Server (NTRS)
Collier, Michael R.; Snowden, S. L.; Sarantos, M.; Benna, M.; Carter, J. A.; Cravens, T. E.; Farrell, W. M.; Fatemi, S.; Hills, H. Kent; Hodges, R. R.;
2014-01-01
We analyze the Rontgen satellite (ROSAT) position sensitive proportional counter soft X-ray image of the Moon taken on 29 June 1990 by examining the radial profile of the surface brightness in three wedges: two 19 deg wedges (one north and one south) 13-32 deg off the terminator toward the dark side and one wedge 38 deg wide centered on the antisolar direction. The radial profiles of both the north and the south wedges show significant limb brightening that is absent in the 38 deg wide antisolar wedge. An analysis of the soft X-ray intensity increase associated with the limb brightening shows that its magnitude is consistent with that expected due to solar wind charge exchange (SWCX) with the tenuous lunar atmosphere based on lunar exospheric models and hybrid simulation results of solar wind access beyond the terminator. Soft X-ray imaging thus can independently infer the total lunar limb column density including all species, a property that before now has not been measured, and provide a large-scale picture of the solar wind-lunar interaction. Because the SWCX signal appears to be dominated by exospheric species arising from solar wind implantation, this technique can also determine how the exosphere varies with solar wind conditions. Now, along with Mars, Venus, and Earth, the Moon represents another solar system body at which SWCX has been observed.
NASA Astrophysics Data System (ADS)
Matsushima, Shinichi; Kosaka, Hiroyuki; Kawase, Hiroshi
2017-07-01
As observational evidence of 3-D microtremor horizontal-to-vertical spectral ratios (MHVRs), previous studies have shown that a significant directional dependency is observed in and around Uji campus, Kyoto University, Japan. This directional dependence is considered to be the result of 2-D basin structure. In this study, we observed microtremors around a strong motion observation site of the Port and Harbor Research Institute in Onahama, Japan, and found that directional dependence of MHVRs exists in some parts of the area around the site. The directional dependence is more apparent and has a higher dominant frequency, at around 5 Hz, relative to those observed in Uji, at around 0.5 Hz. We defined a parameter γ, which we refer to as the "directionally dependent coefficient" to indicate the magnitude of difference between the two orthogonal components which implies the directional dependence of the MHVRs. We rotated the axes and calculated γ for each angle and searched for the orientation that gave the largest γ at a point. Points for which the axis with larger MHVR amplitude among the two axes is oriented in the NS direction are aligned in the NS direction, while points for which the axis with larger MHVR amplitude is oriented in the EW direction are aligned in the EW direction. The distribution of points with large γ formed a T-shaped distribution. We calculated the analytical and numerical MHVRs in order to simulate the observed MHVRs and succeeded in showing the existence of a narrow wedge. From these results, we conclude that a wedge-like lateral heterogeneity exists in the shallow subsurface of the studied area, parallel to the direction of the axis of the larger MHVR amplitude.
1984-12-01
radiation lengths. The off-axis dose in Silicon was calculated using the electron/photon transport code CYLTRAN and measured using thermal luminescent...various path lengths out to 2 radiation lengths. The cff-axis dose in Silicon was calculated using the electron/photon transport code CYLTRAN and measured... using thermal luminescent dosimeters (TLD’s). Calculations were performed on a CDC-7600 computer at Los Alamos National Laboratory and measurements
Pulsed ultrasonic stir welding method
NASA Technical Reports Server (NTRS)
Ding, R. Jeffrey (Inventor)
2013-01-01
A method of performing ultrasonic stir welding uses a welding head assembly to include a plate and a rod passing through the plate. The rod is rotatable about a longitudinal axis thereof. In the method, the rod is rotated about its longitudinal axis during a welding operation. During the welding operation, a series of on-off ultrasonic pulses are applied to the rod such that they propagate parallel to the rod's longitudinal axis. At least a pulse rate associated with the on-off ultrasonic pulses is controlled.
Second harmonic generation of off axial vortex beam in the case of walk-off effect
NASA Astrophysics Data System (ADS)
Chen, Shunyi; Ding, Panfeng; Pu, Jixiong
2016-07-01
Process of off axial vortex beam propagating in negative uniaxial crystal is investigated in this work. Firstly, we get the formulae of the normalized electric field and calculate the location of vortices for second harmonic beam in two type of phase matching. Then, numerical analysis verifies that the intensity distribution and location of vortices of the first order original vortex beam depend on the walk-off angle and off axial magnitude. It is shown that, in type I phase matching, the distribution of vortices is symmetrical about the horizontal axis, the separation distance increases as the off axial magnitude increases or the off axial magnitude deceases. However, in type II phase matching, the vortices are symmetrical along with some vertical axis, and increase of the walk-off angle or off axial magnitude leads to larger separation distance. Finally, the case of high order original off axial vortex beam is also investigated.
[Power in the periphery of several aspheric eyeglasses for aphakic patients].
Simonet, P
1984-01-01
A special device adapted to a Nikon projection vertexometer permits the power to be measured in the periphery of recent aspheric aphakic lenses. The peripheral power is measured with respect to the vertex sphere. A blended lenticular aspheric lens and three types of zonal aspheric full field lenses are studied, with various base curves on three samples. Four meridians of each lens are evaluated with ocular rotations varying by 5 degrees step up to 35 degrees at least. The results show a variable oblique astigmatism and a high under-correction of the mean oblique power for the Welsh 4 drop. The other zonal aspheric lenses give only a slight improvement of the peripheral powers compared with some conventional aspheric lenses. The Omega lens shows a reasonable correction of off-axis power errors up to 30 degrees. Beyond, the powers variation follows the general characteristics of blended lenticular aspheric lenses.
Saito, Kenta; Arai, Yoshiyuki; Zhang, Jize; Kobayashi, Kentaro; Tani, Tomomi; Nagai, Takeharu
2011-01-01
Laser-scanning confocal microscopy has been employed for exploring structures at subcellular, cellular and tissue level in three dimensions. To acquire the confocal image, a coherent light source, such as laser, is generally required in conventional single-point scanning microscopy. The illuminating beam must be focused onto a small spot with diffraction-limited size, and this determines the spatial resolution of the microscopy system. In contrast, multipoint scanning confocal microscopy using a Nipkow disk enables the use of an incoherent light source. We previously demonstrated successful application of a 100 W mercury arc lamp as a light source for the Yokogawa confocal scanner unit in which a microlens array was coupled with a Nipkow disk to focus the collimated incident light onto a pinhole (Saito et al., Cell Struct. Funct., 33: 133-141, 2008). However, transmission efficiency of incident light through the pinhole array was low because off-axis light, the major component of the incident light, was blocked by the non-aperture area of the disk. To improve transmission efficiency, we propose an optical system in which off-axis light is able to be transmitted through pinholes surrounding the pinhole located on the optical axis of the collimator lens. This optical system facilitates the use of not only the on-axis but also the off-axis light such that the available incident light is considerably improved. As a result, we apply the proposed system to high-speed confocal and multicolor imaging both with a satisfactory signal-to-noise ratio.
NASA Astrophysics Data System (ADS)
Webb, S. I.; Tobin, H. J.; Everson, E. D.; Fortin, W.; Holbrook, W. S.; Kent, G.; Keranen, K. M.
2014-12-01
The Cascadia subduction zone has a history of large magnitude earthquakes, but a near-total lack of plate interface seismicity, making the updip limit of the seismogenic zone difficult to locate. In addition, the central Cascadia accretionary prism is characterized by an extremely low wedge taper angle, landward vergent initial thrusting, and a flat midslope terrace between the inner and outer wedges, unlike most other accretionary prisms (e.g. the Nankai Trough, Japan). The Cascadia Open Access Seismic Transect (COAST) lines were shot by R/V Marcus Langseth in July of 2012 off central Washington to image this subduction zone. Two trench-parallel and nine trench-perpendicular lines were collected. In this study, we present detailed seismic interpretation of both time- and depth-migrated stacked profiles, focused on elucidating the deposition and deformation of both pre- and syn-tectonic sediment in the trench and slope. Distribution and timing of sediments and their deformation is used to unravel the evolution of the wedge through time. Initially, interpretation of the time-sections is carried out to support the building of tomographic velocity models to aid in the pre-stack depth migration (PSDM) of selected lines. In turn, we use PSDM velocity models to estimate porosity and pore pressure conditions at the base of the wedge and across the basal plate interface décollement where possible, using established velocity-porosity transforms. Interpretation in this way incorporates both accurate structural relationships and robust porosity models to document wedge development and present-day stress state, in particular regions of potential overpressure. Results shed light on the origin and evolution of the mid-slope terrace and the low taper angle for the forearc wedge. This work may shed light ultimately on the position of the potential updip limit of the seismogenic zone beneath the wedge.
OFF-AXIS THERMAL AND SYNCHROTRON EMISSION FOR SHORT GAMMA RAY BURST
NASA Astrophysics Data System (ADS)
Xie, Xiaoyi
2018-01-01
We present light curves of photospheric and synchrotron emission from a relativistic jet propagating through the ejecta cloud of a neutron star merger. We use a moving-mesh relativistic hydrodynamics code with adaptive mesh refinement to compute the continuous evolution of jet over 13 orders of magnitude in radius from the scale of the central merger engine all the way through the late afterglow phase. As the jet propagates through the cloud it forms a hot cocoon surrounding the jet core. We find that the photospheric emission released by the hot cocoon is bright for on-axis observers and is detectable for off-axis observers at a wide range of observing angles for sufficiently close sources. As the jet and cocoon drive an external shock into the surrounding medium we compute synchrotron light curves and find bright emission for off-axis observers which differs from top-hat Blandford-McKee jets, especially for lower explosion energies.
Orbital Verification of the CXO High-Resolution Mirror Assembly Alignment and Vignetting
NASA Technical Reports Server (NTRS)
Gaetz, T. J.; Jerius, D.; Edgar, R. J.; VanSpeybroeck, L. P.; Schwartz, D. A.; Markevitch, M.; Schulz, N. S.
2000-01-01
Prior to launch, the High Resolution Mirror Assembly (HRMA) of the Chandra X-ray Observatory underwent extensive ground testing at the X-ray Calibration Facility (XRCF) at the Marshall Space Flight Center in Huntsville. Observations made during the post-launch Orbital Activation and Calibration period, allow the on-orbit condition of the X-ray optics to be assessed. Based on these ground-based and on-orbit data, we examine the alignment of the x-ray optics based on the PSF, and the boresight and alignment of the optical axis alignment relative to the detectors. We examine the vignetting and the single reflection ghost suppression properties of the telescope. Slight imperfections in alignment lead to a small azimuthal dependence of the off-axis area; the morphology of off-axis images also shows an additional small azimuthal dependence varying as 1/2 the off-axis azimuth angle.
Shaping off-axis metallic membrane reflectors using optimal boundary shapes and inelastic strains
NASA Technical Reports Server (NTRS)
White, C. V.; Dragovan, M.
2004-01-01
This paper will describe a novel concept for constructing off-axis membrane reflector surfaces. Membrane reflectors have been extensively studied, including investigations into inflated lenticular architectures, shaping by spin casting, shaping using electrostatic forces, and shaping by evacuating behind a membrane surface stretched between circular or annular-shaped supports.
Tsai, Liang-Ching; Lee, Song Joo; Yang, Aaron J.; Ren, Yupeng; Press, Joel M.; Zhang, Li-Qun
2014-01-01
Objective To examine whether an off-axis elliptical training program reduces pain and improves knee function in individuals with patellofemoral pain (PFP). Design Controlled laboratory study, pre-test-post-test. Setting University rehabilitation center. Participants Twelve adult subjects with PFP. Interventions Subjects with PFP completed an exercise program consisting of 18 sessions of lower extremity off-axis training using a custom-made elliptical trainer that allows frontal-plane sliding and transverse-plane pivoting of the footplates. Main Outcome Measures Changes in knee pain and function post-training and 6 weeks following training were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and International Knee Documentation Committee (IKDC) scores. Lower extremity off-axis control was assessed by pivoting and sliding instability, calculated as the root mean square (RMS) of the footplate pivoting angle and sliding distance during elliptical exercise. Subjects’ single-leg hop distance and proprioception in detecting lower extremity pivoting motion were also evaluated. Results Subjects reported significantly greater KOOS and IKDC scores (increased by 12–18 points) and hop distance (increased by 0.2 m) following training. A significant decrease in the pivoting and sliding RMS was also observed following training. Additionally, subjects with PFP demonstrated improved pivoting proprioception when tested under a minimum-weight-bearing position. Conclusions An off-axis elliptical training program was effective in enhancing lower extremity neuromuscular control on the frontal and transverse planes, reducing pain and improving knee function in persons with PFP. PMID:25591131
Madry, Henning; Ziegler, Raphaela; Orth, Patrick; Goebel, Lars; Ong, Mei Fang; Kohn, Dieter; Cucchiarini, Magali; Pape, Dietrich
2013-01-01
To evaluate whether medial open wedge high tibial osteotomy (HTO) results in structural and biochemical changes in the lateral meniscus in adult sheep. Three experimental groups with biplanar osteotomies of the right proximal tibiae were tested: (a) closing wedge HTO resulting in 4.5° of tibial varus, (b) open wedge HTO resulting in 4.5° of tibial valgus (standard correction) and (c) open wedge HTO resulting in 9.5° of valgus (overcorrection), each of which was compared to the contralateral knees with normal limb axes. After 6 months, the lateral menisci were macroscopically and microscopically evaluated. The proteoglycan and DNA contents of the red-red and white-white zones of the anterior, middle and posterior third were determined. Semiquantitative macroscopic and microscopic grading revealed no structural differences between groups. The red-red zone of the middle third of the lateral menisci of animals that underwent overcorrection exhibited a significant 0.7-fold decrease in mean DNA contents compared with the control knee without HTO (P = 0.012). Comparative estimation of the DNA and proteoglycan contents and proteoglycan/DNA ratios of all other parts and zones of the lateral menisci did not reveal significant differences between groups. Open wedge HTO does not lead to significant macroscopic and microscopic structural changes in the lateral meniscus after 6 months in vivo. Overcorrection significantly decreases the proliferative activity of the cells in the red-red zone of the middle third in the sheep model.
Hachem, Bahe; Aubin, Carl-Eric; Parent, Stefan
2017-06-01
Developing fusionless devices to treat pediatric scoliosis necessitates lengthy and expensive animal trials. The objective was to develop and validate a porcine spine numerical model as an alternative platform to assess fusionless devices. A parametric finite element model (FEM) of an osseoligamentous porcine spine and rib cage, including the epiphyseal growth plates, was developed. A follower-type load replicated physiological and gravitational loads. Vertebral growth and its modulation were programmed based on the Hueter-Volkmann principle, stipulating growth reduction/promotion due to increased compressive/tensile stresses. Scoliosis induction via a posterior tether and 5-level rib tethering, was simulated over 10 weeks along with its subsequent correction via a contralateral anterior custom tether (20 weeks). Scoliosis induction was also simulated using two experimentally tested compression-based fusionless implants (hemi- and rigid staples) over 12- and 8-weeks growth, respectively. Resulting simulated Cobb and sagittal angles, apical vertebral wedging, and left/right height alterations were compared to reported studies. Simulated induced Cobb and vertebral wedging were 48.4° and 7.6° and corrected to 21° and 5.4°, respectively, with the contralateral anterior tether. Apical rotation (15.6°) was corrected to 7.4°. With the hemi- and rigid staples, Cobb angle was 11.2° and 11.8°, respectively, with 3.7° and 2.0° vertebral wedging. Sagittal plane was within the published range. Convex/concave-side vertebral height difference was 3.1 mm with the induction posterior tether and reduced to 2.3 with the contralateral anterior tether, with 1.4 and 0.8 for the hemi- and rigid staples. The FEM represented growth-restraining effects and growth modulation with Cobb and vertebral wedging within 0.6° and 1.9° of experimental animal results, while it was within 5° for the two simulated staples. Ultimately, the model would serve as a time- and cost-effective tool to assess the biomechanics and long-term effect of compression-based fusionless devices prior to animal trials, assisting the transfer towards treating scoliosis in the growing spine.
Erratum: Correction to: Water in the Earth's Interior: Distribution and Origin
NASA Astrophysics Data System (ADS)
Peslier, Anne H.; Schönbächler, Maria; Busemann, Henner; Karato, Shun-Ichiro
2017-10-01
Correction to: Space Sci Rev DOI: 10.1007/s11214-017-0387-z This article has been corrected. Figure 3 was initially published with erroneous axis titles in Fig. 3B and 3D where the x axis should be Cpx H2O, instead of Grt H2O.
Waveguide infrared spectrometer platform for point and standoff chemical sensing
NASA Astrophysics Data System (ADS)
Chadha, Suneet; Henning, Pat; Landers, Frank; Weling, Ani
2004-03-01
Advanced autonomous detection of chemical warfare agents and toxic industrial chemicals has long been a major military concern. At present, our capability to rapidly assess the immediate environment is severely limited and our domestic infrastructure is burdened by the meticulous procedures required to rule out false threats. While significant advances have recently been accomplished in remote spectral sensing using rugged FTIRs and point detectors, efforts towards low cost chemical discrimination have been lacking. Foster-Miller has developed a unique waveguide spectrometer which is a paradigm shift from the conventional FTIR approach. The spectrometer provides spectral discrimination over the 3-14 μm range and will be the spectrometer platform for both active and passive detection. Foster-Miller has leveraged its innovations in infrared fiber-optic probes and the recent development of a waveguide spectrometer to build a novel infrared sensor platform for both point and stand-off chemical sensing. A monolithic wedge-grating optic provides the spectral dispersion with low cost thermopile point or array detectors picking off the diffracted wavelengths from the optic. The integrated optic provides spectral discrimination between 3-12 μm with resolution at 16 cm-1 or better and overall optical throughput approaching 35%. The device has a fixed cylindrical grating bonded to the edge of a ZnSe conditioning "wedge". The conditioning optic overcomes limitations of concave gratings as it accepts high angle (large FOV) light at the narrow end of the wedge and progressively conditions it to be near normal to the grating. On return, the diffracted wavelengths are concentrated on the discrete or array detector (pixel) elements by the wedge, providing throughput comparable to that of an FTIR. The waveguide spectrometer coupled to ATR probes, flow through liquid cells or multipass gas cells provides significant cost advantage over conventional sampling methodologies. We will present the enabling innovations along with present performance, sensitivity expectations and discrimination algorithm strategy.
Collot, J.-Y.; Fisher, M.A.
1989-01-01
Seabeam data reveal two deep subcircular reentrants in the lower arc slope of the New Hebrides island arc that may illustrate two stages in the development of a novel type of forearc basin. The Malekula reentrant lies just south of the partly subducted Bougainville seamount. This proximity, as well as the similarity in morphology between the reentrant and an indentation in the lower arc slope off Japan, suggests that the Malekula reentrant formed by the collision of a seamount with the arc. An arcuate fold-thrust belt has formed across the mouth of the reentrant, forming the toe of a new accretionary wedge. The Efate reentrant may show the next stage in basin development. This reentrant lies landward of a lower-slope ridge that may have begun to form as an arcuate fold-thrust belt across the mouth of a reentrant. This belt may have grown by continued accretion at the toe of the wedge, by underplating beneath the reentrant, and by trapping of sediment shed from the island arc. These processes could result in a roughly circular forearc basin. Basins that may have formed by seamount collision lie within the accretionary wedge adjacent to the Aleutian trenches. -Authors
NASA Technical Reports Server (NTRS)
Oliver, D. S.; Aldrich, R. E.; Krol, F. T.
1972-01-01
An electrically addressed liquid crystal Fourier plane filter capable of real time optical image processing is described. The filter consists of two parts: a wedge filter having forty 9 deg segments and a ring filter having twenty concentric rings in a one inch diameter active area. Transmission of the filter in the off (transparent) state exceeds fifty percent. By using polarizing optics, contrast as high as 10,000:1 can be achieved at voltages compatible with FET switching technology. A phenomenological model for the dynamic scattering is presented for this special case. The filter is designed to be operated from a computer and is addressed by a seven bit binary word which includes an on or off command and selects any one of the twenty rings or twenty wedge pairs. The overall system uses addressable latches so that once an element is in a specified state, it will remain there until a change of state command is received. The drive for the liquid crystal filter is ? 30 V peak at 30 Hz to 70 Hz. These parameters give a rise time for the scattering of 20 msec and a decay time of 80 to 100 msec.
1992-02-29
are co-boresighted with dual-axis Risley prisms which are mounted in the extension of the laser cavity at the periphery of the telescope primary...unwanted optical feedback into the lasers, the fiber was polished with a wedge angle of approximately 10 degrees. The fiber tip was brought to less
NASA Technical Reports Server (NTRS)
Haynie, C. C.
1980-01-01
Simple gage, used with template, can help inspectors determine whether three-dimensional curved surface has correct contour. Gage was developed as aid in explosive forming of Space Shuttle emergency-escape hatch. For even greater accuracy, wedge can be made of metal and calibrated by indexing machine.
NASA Astrophysics Data System (ADS)
Kergaravat, Charlie; Ribes, Charlotte; Darnault, Romain; Callot, Jean-Paul; Ringenbach, Jean-Claude
2017-04-01
The aim of this study is to present the influence of regional shortening on the evolution of a minibasin province and the associated foldbelt geometry based on a natural example, the Sivas Basin, then compared to a physical experiment. The Sivas Basin in the Central Anatolian Plateau (Turkey) is a foreland fold-and-thrust belt, displaying in the central part a typical wall and basin province characterized by spectacularly exposed minibasins, separated by continuous steep-flanked walls and diapirs over a large area (45x25 km). The advance of the orogenic wedge is expressed within the second generation of minibasins by a shortening-induced squeezing of diapirs. Network of walls and diapirs evolve form polygonal to linear pattern probably induced by the squeezing of pre-existing evaporite walls and diapirs, separating linear primary minibasins. From base to top of secondary minibasins, halokinetic structures seem to evolve from small-scale objects along diapir flanks, showing hook and wedges halokinetic sequences, to large stratigraphic wedging, megaflap and salt sheets. Minibasins show progressively more linear shape at right angle to the regional shortening and present angular unconformities along salt structures related to the rejuvenation of pre-existing salt diapirs and walls probably encouraged by the shortening tectonic regime. The advance of the fold-and-thrust belts during the minibasins emplacement is mainly expressed during the late stage of minibasins development by a complex polygonal network of small- and intermediate-scale tectonic objects: (1) squeezed evaporite walls and diapirs, sometimes thrusted forming oblique or vertical welds, (2) allochthonous evaporite sheets, (3) thrusts and strike-slip faults recording translation and rotation of minibasins about vertical axis. Some minibasins are also tilted, with up to vertical position, associated with both the salt expulsion during minibasins sinking, recorded by large stratigraphic wedge, and the late thrust faults developments. The influence of the regional shortening deformation seems to be effective when the majority of the evaporite is remobilized toward the foreland. Results of scaled physical experiments, where continuous shortening is applied during minibasins emplacement, closely match with the deformation patterns observed in the Sivas minibasins. Shortening induce deformations such as translation of minibasins basinward, strike-slip fault zones along minibasin margin, rejuvenation of silicon walls and diapirs, emergence of silicon glaciers and rotation of minibasins along vertical and horizontal axis.
Rouvillain, J L; Lavallé, F; Pascal-Mousselard, H; Catonné, Y; Daculsi, G
2009-10-01
We report clinical, radiological and histological findings following high tibial valgisation osteotomy (HTVO) using micro-macroporous biphasic calcium phosphate wedges fixed with a plate and locking screws. From 1999 to 2002, 43 knees were operated on and studied prospectively. All underwent clinical and radiological follow-up at days 1, 90, and 365 to evaluate consolidation and bone substitute interfaces. Additionally, biopsies were taken for histology at least 1 year after implantation from 10 patients who requested plate removal. Radiologically, consolidation was observed in 98% of cases. At 1 year, correction was unchanged in 95% of cases. Histological analysis revealed considerable MBCP resorption and bone ingrowth, both into the pores and replacing the bioceramic material. Polarised light microscopy confirmed normal bony architecture with trabecular and/or dense lamellar bone growth at the expense of the wedge implants. X-ray and micro-CT scan revealed a well organised and mineralised structure in the newly-formed bone. This study shows that using MBCP wedges in combination with orientable locking screws and a plate is a simple, safe and fast surgical technique for HTVO. The is the first study to examine the results by histological analysis, which confirmed good outcomes.
Bové, J C
2002-09-01
The aim of this work was to study the behavior of an inert porous alumina ceramic spacer used with a plate fixation for open-wedge tibial valgus osteotomy in patients with osteoarthritis of the knee and genu varum. The population included 50 patients who underwent surgery between October 1994 and December 2000. There were 31 women and 19 men, mean age 55 years at surgery (26 right knees and 24 left knees). Patients were reviewed at 3 weeks, 6 weeks, 3 months, 6 months, and one year, then every 2 years. Clinical and radiological data were available for all patients. Mean follow-up was 16 months. Two patients were lost to follow-up at 5 and 6 months. The results of the open-wedge tibial osteotomy were in agreement with the usual outcome reported in the literature concerning pain relief, functional recovery, joint motion, angle correction, and good preservation of the clinical and radiological result. Three fracture lines were observed on the lateral tibial plateau but did not affect final outcome or angle correction. There was however one case with loss of correction due to fracture of the screws. Radiographically, at 6 months, there were 9 thin lucent lines around the spacer (24%) which did not affect final outcome. Bone healing was achieved at 3 months on the average in all cases except 2 (4%) where healing was achieved at 8 and 13 months. The porous alumine spacer is a reliable biocompatible and mechanically stable element helpful for achieving bone healing. Integration into bone tissue was radiographically satisfactory. There were no specific complications related to use of the spacer.
Correlating off-axis tension tests to shear modulus of wood-based panels
Edmond P. Saliklis; Robert H. Falk
2000-01-01
The weakness of existing relationships correlating off-axis modulus of elasticity E q to shear modulus G 12 for wood composite panels is demonstrated through presentation of extensive experimental data. A new relationship is proposed that performs better than existing equations found in the literature. This relationship can be manipulated to calculate the shear modulus...
Observation of hole accumulation in Ge/Si core/shell nanowires using off-axis electron holography.
Li, Luying; Smith, David J; Dailey, Eric; Madras, Prashanth; Drucker, Jeff; McCartney, Martha R
2011-02-09
Hole accumulation in Ge/Si core/shell nanowires (NWs) has been observed and quantified using off-axis electron holography and other electron microscopy techniques. The epitaxial [110]-oriented Ge/Si core/shell NWs were grown on Si (111) substrates by chemical vapor deposition through the vapor-liquid-solid growth mechanism. High-angle annular-dark-field scanning transmission electron microscopy images and off-axis electron holograms were obtained from specific NWs. The excess phase shifts measured by electron holography across the NWs indicated the presence of holes inside the Ge cores. Calculations based on a simplified coaxial cylindrical model gave hole densities of (0.4 ± 0.2) /nm(3) in the core regions.
Optical control of the Advanced Technology Solar Telescope.
Upton, Robert
2006-08-10
The Advanced Technology Solar Telescope (ATST) is an off-axis Gregorian astronomical telescope design. The ATST is expected to be subject to thermal and gravitational effects that result in misalignments of its mirrors and warping of its primary mirror. These effects require active, closed-loop correction to maintain its as-designed diffraction-limited optical performance. The simulation and modeling of the ATST with a closed-loop correction strategy are presented. The correction strategy is derived from the linear mathematical properties of two Jacobian, or influence, matrices that map the ATST rigid-body (RB) misalignments and primary mirror figure errors to wavefront sensor (WFS) measurements. The two Jacobian matrices also quantify the sensitivities of the ATST to RB and primary mirror figure perturbations. The modeled active correction strategy results in a decrease of the rms wavefront error averaged over the field of view (FOV) from 500 to 19 nm, subject to 10 nm rms WFS noise. This result is obtained utilizing nine WFSs distributed in the FOV with a 300 nm rms astigmatism figure error on the primary mirror. Correction of the ATST RB perturbations is demonstrated for an optimum subset of three WFSs with corrections improving the ATST rms wavefront error from 340 to 17.8 nm. In addition to the active correction of the ATST, an analytically robust sensitivity analysis that can be generally extended to a wider class of optical systems is presented.
Steerable vertical to horizontal energy transducer for mobile robots
Spletzer, Barry L.; Fischer, Gary J.; Feddema, John T.
2001-01-01
The present invention provides a steerable vertical to horizontal energy transducer for mobile robots that less complex and requires less power than two degree of freedom tilt mechanisms. The present invention comprises an end effector that, when mounted with a hopping actuator, translates along axis (typically vertical) actuation into combined vertical and horizontal motion. The end effector, or foot, mounts with an end of the actuator that moves toward the support surface (typically a floor or the earth). The foot is shaped so that the first contact with the support surface is off the axis of the actuator. Off-axis contact with the support surface generates an on-axis force (typically resulting in vertical motion) and a moment orthogonal to the axis. The moment initiates a horizontal tumbling motion, and tilts the actuator so that its axis is oriented with a horizontal component and continued actuation generates both vertical and horizontal force.
Simulation and modeling of silicon pore optics for the ATHENA x-ray telescope
NASA Astrophysics Data System (ADS)
Spiga, D.; Christensen, F. E.; Bavdaz, M.; Civitani, M. M.; Conconi, P.; Della Monica Ferreira, D.; Knudsen, E. B.; Massahi, S.; Pareschi, G.; Salmaso, B.; Shortt, B.; Tayabaly, K.; Westergaard, N. J.; Wille, E.
2016-07-01
The ATHENA X-ray observatory is a large-class ESA approved mission, with launch scheduled in 2028. The technology of silicon pore optics (SPO) was selected as baseline to assemble ATHENA's optic with more than 1000 mirror modules, obtained by stacking wedged and ribbed silicon wafer plates onto silicon mandrels to form the Wolter-I configuration. Even if the current baseline design fulfills the required effective area of 2 m2 at 1 keV on-axis, alternative design solutions, e.g., privileging the field of view or the off-axis angular resolution, are also possible. Moreover, the stringent requirement of a 5 arcsec HEW angular resolution at 1 keV entails very small profile errors and excellent surface smoothness, as well as a precise alignment of the 1000 mirror modules to avoid imaging degradation and effective area loss. Finally, the stray light issue has to be kept under control. In this paper we show the preliminary results of simulations of optical systems based on SPO for the ATHENA X-ray telescope, from pore to telescope level, carried out at INAF/OAB and DTU Space under ESA contract. We show ray-tracing results, including assessment of the misalignments of mirror modules and the impact of stray light. We also deal with a detailed description of diffractive effects expected in an SPO module from UV light, where the aperture diffraction prevails, to X-rays where the surface diffraction plays a major role. Finally, we analyze the results of X-ray tests performed at the BESSY synchrotron, we compare them with surface finishing measurements, and we estimate the expected HEW degradation caused by the X-ray scattering.
Reactor Pressure Vessel Fracture Analysis Capabilities in Grizzly
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, Benjamin; Backman, Marie; Chakraborty, Pritam
2015-03-01
Efforts have been underway to develop fracture mechanics capabilities in the Grizzly code to enable it to be used to perform deterministic fracture assessments of degraded reactor pressure vessels (RPVs). Development in prior years has resulted a capability to calculate -integrals. For this application, these are used to calculate stress intensity factors for cracks to be used in deterministic linear elastic fracture mechanics (LEFM) assessments of fracture in degraded RPVs. The -integral can only be used to evaluate stress intensity factors for axis-aligned flaws because it can only be used to obtain the stress intensity factor for pure Mode Imore » loading. Off-axis flaws will be subjected to mixed-mode loading. For this reason, work has continued to expand the set of fracture mechanics capabilities to permit it to evaluate off-axis flaws. This report documents the following work to enhance Grizzly’s engineering fracture mechanics capabilities for RPVs: • Interaction Integral and -stress: To obtain mixed-mode stress intensity factors, a capability to evaluate interaction integrals for 2D or 3D flaws has been developed. A -stress evaluation capability has been developed to evaluate the constraint at crack tips in 2D or 3D. Initial verification testing of these capabilities is documented here. • Benchmarking for axis-aligned flaws: Grizzly’s capabilities to evaluate stress intensity factors for axis-aligned flaws have been benchmarked against calculations for the same conditions in FAVOR. • Off-axis flaw demonstration: The newly-developed interaction integral capabilities are demon- strated in an application to calculate the mixed-mode stress intensity factors for off-axis flaws. • Other code enhancements: Other enhancements to the thermomechanics capabilities that relate to the solution of the engineering RPV fracture problem are documented here.« less
High frequency capacitance-voltage characteristics of thermally grown SiO2 films on beta-SiC
NASA Technical Reports Server (NTRS)
Tang, S. M.; Berry, W. B.; Kwor, R.; Zeller, M. V.; Matus, L. G.
1990-01-01
Silicon dioxide films grown under dry and wet oxidation environment on beta-SiC films have been studied. The beta-SiC films had been heteroepitaxially grown on both on-axis and 2-deg off-axis (001) Si substrates. Capacitance-voltage and conductance-voltage characteristics of metal-oxide-semiconductor structures were measured in a frequency range of 10 kHz to 1 MHz. From these measurements, the interface trap density and the effective fixed oxide charge density were observed to be generally lower for off-axis samples.
On the maximum off-axis gain of symmetrical pencil-beam antennas
NASA Technical Reports Server (NTRS)
Sawitz, P. H.
1977-01-01
For a general class of symmetrical pencil-beam antennas, the gain at a given off-axis angle can be maximized by choosing the proper antenna size. The maximum gain at the given angle relative to the on-axis gain is independent of the given angle and dependent only on the main-beam pattern. It is computed here for four commonly used gain functions. Its value, in all cases, is close to 4 dB. This result is important in the definition of service areas for communication and broadcast satellites.
Endurance testing of downstream cathodes on a low-power MPD thruster
NASA Technical Reports Server (NTRS)
Burkhart, J. A.; Rose, J. R.
1974-01-01
A low-power MPD thruster with downstream cathode was tested for endurance with a series of hollow cathode designs. Failure modes and failure mechanisms were identified. A new hollow cathode (with rod inserts) has emerged which shows promise for long life. The downstream positioning of the cathode was also changed from an on-axis location to an off-axis location. Data are presented for a 1332-hour life test of this new hollow cathode located at the new off-axis location. Xenon propellant was used.
Two-point motional Stark effect diagnostic for Madison Symmetric Torus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, J.; Den Hartog, D. J.; Caspary, K. J.
2010-10-15
A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views - on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from MSE spectra. Systematic errors are reduced by using atomic data from atomic data and analysis structure in the fit. Reconstructed current density and safety factor profiles are more strongly and globally constrained with the addition of the off-axis radiusmore » measurement than with the on-axis one only.« less
Off-axis current drive and real-time control of current profile in JT-60U
NASA Astrophysics Data System (ADS)
Suzuki, T.; Ide, S.; Oikawa, T.; Fujita, T.; Ishikawa, M.; Seki, M.; Matsunaga, G.; Hatae, T.; Naito, O.; Hamamatsu, K.; Sueoka, M.; Hosoyama, H.; Nakazato, M.; JT-60 Team
2008-04-01
Aiming at optimization of current profile in high-β plasmas for higher confinement and stability, a real-time control system of the minimum of the safety factor (qmin) using the off-axis current drive has been developed. The off-axis current drive can raise the safety factor in the centre and help to avoid instability that limits the performance of the plasma. The system controls the injection power of lower-hybrid waves, and hence its off-axis driven current in order to control qmin. The real-time control of qmin is demonstrated in a high-β plasma, where qmin follows the temporally changing reference qmin,ref from 1.3 to 1.7. Applying the control to another high-β discharge (βN = 1.7, βp = 1.5) with m/n = 2/1 neo-classical tearing mode (NTM), qmin was raised above 2 and the NTM was suppressed. The stored energy increased by 16% with the NTM suppressed, since the resonant rational surface was eliminated. For the future use for current profile control, current density profile for off-axis neutral beam current drive (NBCD) is for the first time measured, using the motional Stark effect diagnostic. Spatially localized NBCD profile was clearly observed at the normalized minor radius ρ of about 0.6-0.8. The location was also confirmed by multi-chordal neutron emission profile measurement. The total amount of the measured beam driven current was consistent with the theoretical calculation using the ACCOME code. The CD location in the calculation was inward shifted than the measurement.
NASA Astrophysics Data System (ADS)
Lytle, M. L.; Kelley, K. A.; Wanless, V. D.; Hauri, E. H.
2017-12-01
The East Pacific Rise is a fast spreading mid-ocean ridge system (6-16cm/yr) consisting of many spreading ridges and transform faults. Focusing on a well-studied segment between 8-12°N, we present new SIMS measurements of magmatic volatiles (H2O, CO2, S, Cl, F) and new LA-ICP-MS trace element data in both on-axis and off-axis glasses, coupled with previously published data and use these data to relate melt composition to crystallization and melting processes. The seamounts range in composition from evolved (MgO = 5.54 wt%) to fairly primitive (MgO = 9.70 wt%), whereas on-axis samples have a narrower range of MgO (5.85 - 8.83 wt%). Seamounts span a wide range of enrichment in trace element compositions (La/Sm 0.45 - 4.63; Th/La 0.02 - 0.14; K/Ti 0.02 - 0.66), whereas on-axis glasses reflect NMORB compositions (La/Sm 0.5 - 1; Th/La 0.035 - 0.07; K/Ti 0.05 - 0.15). Light rare earth elements in the seamounts vary from depleted to enriched and have variable Eu anomalies (0.79 - 1.10), while on-axis samples have NMORB patterns with more negative Eu anomalies (0.74 - 1.00). The H2O content of the seamounts ranges from dry (0.05 wt%) to fairly wet (0.96 wt%), whereas on-axis samples have a narrower range (0.15 - 0.31 wt%). Cl contents show variable mixing between seawater and a magmatic component, with seamounts assimilating more seawater. Magmatic liquid lines of descent (LLD), recorded in glass, reflect fractional crystallization of olivine, plagioclase, and clinopyroxene, consistent with modal phenocryst abundances of the rocks. A multi-element approach (e.g., MgO vs. Al2O3, CaO, CaO/Al2O3), constrains LLDs, providing fractionation slopes, allowing mafic basalt compositions to be accurately corrected back to primary melts in equilibrium with Fo90. Using these melts, pressures and temperatures of melt equilibration can be constrained using melt thermobarometry. On-axis samples reflect higher PT conditions (1371°C; 1.37 GPa), although within error of seamounts (1340°C; 1.25 GPa). Overall, on-axis samples are more homogeneous, likely reflecting residence and homogenization of magma batches in an axial magma chamber, whereas off-axis seamounts reflect greater heterogeneity that arises from the localized nature of seamount magmatic systems and extraction of smaller-volume, discrete magma batches from the ridge mantle.
Proton beam deflection in MRI fields: Implications for MRI-guided proton therapy.
Oborn, B M; Dowdell, S; Metcalfe, P E; Crozier, S; Mohan, R; Keall, P J
2015-05-01
This paper investigates, via magnetic modeling and Monte Carlo simulation, the ability to deliver proton beams to the treatment zone inside a split-bore MRI-guided proton therapy system. Field maps from a split-bore 1 T MRI-Linac system are used as input to geant4 Monte Carlo simulations which model the trajectory of proton beams during their paths to the isocenter of the treatment area. Both inline (along the MRI bore) and perpendicular (through the split-bore gap) orientations are simulated. Monoenergetic parallel and diverging beams of energy 90, 195, and 300 MeV starting from 1.5 and 5 m above isocenter are modeled. A phase space file detailing a 2D calibration pattern is used to set the particle starting positions, and their spatial location as they cross isocenter is recorded. No beam scattering, collimation, or modulation of the proton beams is modeled. In the inline orientation, the radial symmetry of the solenoidal style fringe field acts to rotate the protons around the beam's central axis. For protons starting at 1.5 m from isocenter, this rotation is 19° (90 MeV) and 9.8° (300 MeV). A minor focusing toward the beam's central axis is also seen, but only significant, i.e., 2 mm shift at 150 mm off-axis, for 90 MeV protons. For the perpendicular orientation, the main MRI field and near fringe field act as the strongest to deflect the protons in a consistent direction. When starting from 1.5 m above isocenter shifts of 135 mm (90 MeV) and 65 mm (300 MeV) were observed. Further to this, off-axis protons are slightly deflected toward or away from the central axis in the direction perpendicular to the main deflection direction. This leads to a distortion of the phase space pattern, not just a shift. This distortion increases from zero at the central axis to 10 mm (90 MeV) and 5 mm (300 MeV) for a proton 150 mm off-axis. In both orientations, there is a small but subtle difference in the deflection and distortion pattern between protons fired parallel to the beam axis and those fired from a point source. This is indicative of the 3D spatially variant nature of the MRI fringe field. For the first time, accurate magnetic and Monte Carlo modeling have been used to assess the transport of generic proton beams toward a 1 T split-bore MRI. Significant rotation is observed in the inline orientation, while more complex deflection and distortion are seen in the perpendicular orientation. The results of this study suggest that due to the complexity and energy-dependent nature of the magnetic deflection and distortion, the pencil beam scanning method will be the only choice for delivering a therapeutic proton beam inside a potential MRI-guided proton therapy system in either the inline or perpendicular orientation. Further to this, significant correction strategies will be required to account for the MRI fringe fields.
Ultrasonic friction power during Al wire wedge-wedge bonding
NASA Astrophysics Data System (ADS)
Shah, A.; Gaul, H.; Schneider-Ramelow, M.; Reichl, H.; Mayer, M.; Zhou, Y.
2009-07-01
Al wire bonding, also called ultrasonic wedge-wedge bonding, is a microwelding process used extensively in the microelectronics industry for interconnections to integrated circuits. The bonding wire used is a 25μm diameter AlSi1 wire. A friction power model is used to derive the ultrasonic friction power during Al wire bonding. Auxiliary measurements include the current delivered to the ultrasonic transducer, the vibration amplitude of the bonding tool tip in free air, and the ultrasonic force acting on the bonding pad during the bond process. The ultrasonic force measurement is like a signature of the bond as it allows for a detailed insight into mechanisms during various phases of the process. It is measured using piezoresistive force microsensors integrated close to the Al bonding pad (Al-Al process) on a custom made test chip. A clear break-off in the force signal is observed, which is followed by a relatively constant force for a short duration. A large second harmonic content is observed, describing a nonsymmetric deviation of the signal wave form from the sinusoidal shape. This deviation might be due to the reduced geometrical symmetry of the wedge tool. For bonds made with typical process parameters, several characteristic values used in the friction power model are determined. The ultrasonic compliance of the bonding system is 2.66μm/N. A typical maximum value of the relative interfacial amplitude of ultrasonic friction is at least 222nm. The maximum interfacial friction power is at least 11.5mW, which is only about 4.8% of the total electrical power delivered to the ultrasonic generator.
Analysis of off-axis tension test of wood specimens
Jen Y. Liu
2002-01-01
This paper presents a stress analysis of the off-axis tension test of clear wood specimens based on orthotropic elasticity theory. The effects of Poisson's ratio and shear coupling coefficient on stress distribution are analyzed in detail. The analysis also provides a theoretical foundation for the selection of a 10° grain angle in wood specimens for the...
High aperture off-axis parabolic mirror applied in digital holographic microscopy
NASA Astrophysics Data System (ADS)
Kalenkov, Georgy S.; Kalenkov, Sergey G.; Shtanko, Alexander E.
2018-04-01
An optical scheme of recording digital holograms of micro-objects based on high numerical aperture off-axis parabolic mirror forming a high aperture reference wave is suggested. Registration of digital holograms based on the proposed optical scheme is confirmed experimentally. Application of the proposed approach for hyperspectral holograms registration of micro-objects in incoherent light is discussed.
Testing the TPF Interferometry Approach before Launch
NASA Technical Reports Server (NTRS)
Serabyn, Eugene; Mennesson, Bertrand
2006-01-01
One way to directly detect nearby extra-solar planets is via their thermal infrared emission, and with this goal in mind, both NASA and ESA are investigating cryogenic infrared interferometers. Common to both agencies' approaches to faint off-axis source detection near bright stars is the use of a rotating nulling interferometer, such as the Terrestrial Planet Finder interferometer (TPF-I), or Darwin. In this approach, the central star is nulled, while the emission from off-axis sources is transmitted and modulated by the rotation of the off-axis fringes. Because of the high contrasts involved, and the novelty of the measurement technique, it is essential to gain experience with this technique before launch. Here we describe a simple ground-based experiment that can test the essential aspects of the TPF signal measurement and image reconstruction approaches by generating a rotating interferometric baseline within the pupil of a large singleaperture telescope. This approach can mimic potential space-based interferometric configurations, and allow the extraction of signals from off-axis sources using the same algorithms proposed for the space-based missions. This approach should thus allow for testing of the applicability of proposed signal extraction algorithms for the detection of single and multiple near-neighbor companions...
Petrovic, Borislava; Grzadziel, Aleksandra; Rutonjski, Laza; Slosarek, Krzysztof
2010-09-01
Enhanced dynamic wedges (EDW) are known to increase drastically the radiation therapy treatment efficiency. This paper has the aim to compare linear array measurements of EDW with the calculations of treatment planning system (TPS) and the electronic portal imaging device (EPID) for 15 MV photon energy. The range of different field sizes and wedge angles (for 15 MV photon beam) were measured by the linear chamber array CA 24 in Blue water phantom. The measurement conditions were applied to the calculations of the commercial treatment planning system XIO CMS v.4.2.0 using convolution algorithm. EPID measurements were done on EPID-focus distance of 100 cm, and beam parameters being the same as for CA24 measurements. Both depth doses and profiles were measured. EDW linear array measurements of profiles to XIO CMS TPS calculation differ around 0.5%. Profiles in non-wedged direction and open field profiles practically do not differ. Percentage depth doses (PDDs) for all EDW measurements show the difference of not more than 0.2%, while the open field PDD is almost the same as EDW PDD. Wedge factors for 60 deg wedge angle were also examined, and the difference is up to 4%. EPID to linear array differs up to 5%. The implementation of EDW in radiation therapy treatments provides clinicians with an effective tool for the conformal radiotherapy treatment planning. If modelling of EDW beam in TPS is done correctly, a very good agreement between measurements and calculation is obtained, but EPID cannot be used for reference measurements.
Toda, Yoshitaka; Tsukimura, Noriko
2004-10-01
To assess the effect of a lateral-wedge insole with elastic strapping of the subtalar joint on the femorotibial angle in patients with varus deformity of the knee. The efficacy of a wedged insole with subtalar straps and that of a traditional wedged insole shoe insert were compared. Sixty-six female outpatients with knee osteoarthritis (OA) were randomized (according to birth date) to be treated with either the strapped or the traditional inserted insole. Standing radiographs with unilateral insole use were used to analyze the femorotibial angles for each patient. In both groups, the baseline and 6-month visual analog scale (VAS) scores for subjective knee pain and the Lequesne index scores for knee OA were compared. The 61 patients who completed the 6-month study were evaluated. At baseline, there was no significant difference in the femorotibial angle (P = 0.66) and the VAS score (P = 0.75) between the 2 groups. At the 6-month assessment, the 29 subjects wearing the subtalar-strapped insole demonstrated a significantly decreased femorotibial angle (P < 0.0001) and significantly improved VAS scores (P = 0.001) and Lequesne index scores (P = 0.033) compared with their baseline assessments. These significant differences were not observed in the 32 subjects assigned to the traditional shoe-inserted wedged insole. These results suggest that an insole with a subtalar strap maintained the valgus correction of the femorotibial angle in patients with varus knee OA for 6 months, indicating longer-term clinical improvement with the strapped insert compared with the traditional insert. Copyright 2004 American College of Rheumatology
Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.
Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka
2016-01-01
Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Three-body effects in Casimir-Polder repulsion
NASA Astrophysics Data System (ADS)
Milton, Kimball A.; Abalo, E. K.; Parashar, Prachi; Pourtolami, Nima; Brevik, Iver; Ellingsen, Simen Å.; Buhmann, Stefan Yoshi; Scheel, Stefan
2015-04-01
In this paper we study an archetypical scenario in which repulsive Casimir-Polder forces between an atom or molecule and two macroscopic bodies can be achieved. This is an extension of previous studies of the interaction between a polarizable atom and a wedge, in which repulsion occurs if the atom is sufficiently anisotropic and close enough to the symmetry plane of the wedge. A similar repulsion occurs if such an atom passes a thin cylinder or a wire. An obvious extension is to compute the interaction between such an atom and two facing wedges, which includes as a special case the interaction of an atom with a conducting screen possessing a slit, or between two parallel wires. To this end we further extend the electromagnetic multiple-scattering formalism for three-body interactions. To test this machinery we reinvestigate the interaction of a polarizable atom between two parallel conducting plates. In that case, three-body effects are shown to be small and are dominated by three- and four-scattering terms. The atom-wedge calculation is illustrated by an analogous scalar situation, described in the Appendix. The wedge-wedge-atom geometry is difficult to analyze because this is a scale-free problem. However, it is not so hard to investigate the three-body corrections to the interaction between an anisotropic atom or nanoparticle and a pair of parallel conducting cylinders and show that the three-body effects are very small and do not affect the Casimir-Polder repulsion at large distances between the cylinders. Finally, we consider whether such highly anisotropic atoms needed for repulsion are practically realizable. Since this appears rather difficult to accomplish, it may be more feasible to observe such effects with highly anisotropic nanoparticles.
NASA Astrophysics Data System (ADS)
Malyutin, A. A.
2007-03-01
Modes of a laser with plano-spherical degenerate and nondegenerate resonators are calculated upon diode pumping producing the Gaussian gain distribution in the active medium. Axially symmetric and off-axis pumpings are considered. It is shown that in the first case the lowest Hermite-Gaussian mode is excited with the largest weight both in the degenerate and nondegenerate resonator if the pump level is sufficiently high or the characteristic size wg of the amplifying region greatly exceeds the mode radius w0. The high-order Ince-Gaussian modes are excited upon weak off-axis pumping in the nondegenerate resonator both in the absence and presence of the symmetry of the gain distribution with respect to the resonator axis. It is found that when the level of off-axis symmetric pumping of the resonator is high enough, modes with the parameters of the TEM00 mode periodically propagating over a closed path in the resonator can exist. The explanation of this effect is given.
Ten Deg Off-Axis Test for Shear Properties in Fiber Composites
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1977-01-01
A combined theoretical and experimental investigation was conducted to assess the suitability of the 10 deg off-axis tensile test specimen for the intralaminar shear characterization of unidirectional composites. Composite mechanics, a combined-stress failure criterion, and a finite variation across the specimen width and the relative stress and strain magnitudes at the 10 deg plane. Strain gages were used to measure the strain variation across the specimen width at specimen midlength and near the end tabs. Specimens from Mod-I/epoxy, T-300/epoxy, and S-glass/epoxy were used in the experimental program. It was found that the 10 deg off-axis tensile test specimen is suitable for intralaminar shear characterization, and it is recommended that it should be considered as a possible standard test specimen for such a characterization.
Sparsity based terahertz reflective off-axis digital holography
NASA Astrophysics Data System (ADS)
Wan, Min; Muniraj, Inbarasan; Malallah, Ra'ed; Zhao, Liang; Ryle, James P.; Rong, Lu; Healy, John J.; Wang, Dayong; Sheridan, John T.
2017-05-01
Terahertz radiation lies between the microwave and infrared regions in the electromagnetic spectrum. Emitted frequencies range from 0.1 to 10 THz with corresponding wavelengths ranging from 30 μm to 3 mm. In this paper, a continuous-wave Terahertz off-axis digital holographic system is described. A Gaussian fitting method and image normalisation techniques were employed on the recorded hologram to improve the image resolution. A synthesised contrast enhanced hologram is then digitally constructed. Numerical reconstruction is achieved using the angular spectrum method of the filtered off-axis hologram. A sparsity based compression technique is introduced before numerical data reconstruction in order to reduce the dataset required for hologram reconstruction. Results prove that a tiny amount of sparse dataset is sufficient in order to reconstruct the hologram with good image quality.
Lim, Jun; Park, So Yeong; Huang, Jung Yun; Han, Sung Mi; Kim, Hong-Tae
2013-01-01
We developed an off-axis-illuminated zone-plate-based hard x-ray Zernike phase-contrast microscope beamline at Pohang Light Source. Owing to condenser optics-free and off-axis illumination, a large field of view was achieved. The pinhole-type Zernike phase plate affords high-contrast images of a cell with minimal artifacts such as the shade-off and halo effects. The setup, including the optics and the alignment, is simple and easy, and allows faster and easier imaging of large bio-samples.
NASA Astrophysics Data System (ADS)
Wilde, C.; Langehanenberg, P.; Schenk, T.
2017-10-01
For modern production of micro lens systems, such as cementing of doublets or more lenses, precise centering of the lens edge is crucial. Blocking the lens temporarily on a centering arbor ensures that the centers of all optical lens surfaces coincide with the lens edge, while the arbor's axis serves as reference for both alignment and edging process. This theoretical assumption of the traditional cementing technology is not applicable for high-end production. In reality cement wedges between the bottom lens surface and the arbor's ring knife edge may occur and even expensive arbors with single-micron precision suffer from reduced quality of the ring knife edge after multiple usages and cleaning cycles. Consequently, at least the position of the bottom lens surface is undefined and the optical axis does not coincide with the arbor's reference axis! In order to overcome this basic problem in using centering arbors, we present a novel and efficient technique which can measure and align both surfaces of a lens with respect to the arbor axis with high accuracy and furthermore align additional lenses to the optical axis of the bottom lens. This is accomplished by aligning the lens without mechanical contact to the arbor. Thus the lens can be positioned in four degrees of freedom, while the centration errors of all lens surfaces are measured and considered. Additionally the arbor's reference axis is not assumed to be aligned to the rotation axis, but simultaneously measured with high precision.
Improved Strength and Toughness of Carbon Woven Fabric Composites with Functionalized MWCNTs
Soliman, Eslam; Kandil, Usama; Reda Taha, Mahmoud
2014-01-01
This investigation examines the role of carboxyl functionalized multi-walled carbon nanotubes (COOH-MWCNTs) in the on- and off-axis flexure and the shear responses of thin carbon woven fabric composite plates. The chemically functionalized COOH-MWCNTs were used to fabricate epoxy nanocomposites and, subsequently, carbon woven fabric plates to be tested on flexure and shear. In addition to the neat epoxy, three loadings of COOH-MWCNTs were examined: 0.5 wt%, 1.0 wt% and 1.5 wt% of epoxy. While no significant statistical difference in the flexure response of the on-axis specimens was observed, significant increases in the flexure strength, modulus and toughness of the off-axis specimens were observed. The average increase in flexure strength and flexure modulus with the addition of 1.5 wt% COOH-MWCNTs improved by 28% and 19%, respectively. Finite element modeling is used to demonstrate fiber domination in on-axis flexure behavior and matrix domination in off-axis flexure behavior. Furthermore, the 1.5 wt% COOH-MWCNTs increased the toughness of carbon woven composites tested on shear by 33%. Microstructural investigation using Fourier Transform Infrared Spectroscopy (FTIR) proves the existence of chemical bonds between the COOH-MWCNTs and the epoxy matrix. PMID:28788698
A Case of Successful Surgical Repair for Pectus Arcuatum Using Chondrosternoplasty
Kim, Sang Yoon; Park, Samina; Kim, Eung Rae; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun
2016-01-01
Pectus arcuatum is a rare complex chest wall deformity. A 31-year-old female presented with a severely protruding upper sternum combined with a concave lower sternum. We planned a modified Ravitch-type operation. Through vertical mid-sternal incision, chondrectomies were performed from the second to fifth costal cartilages, saving the perichondrium. Horizontal osteotomy was performed in a wedge shape on the most protruding point, and followed by an additional partial osteotomy at the most concaved point. The harvested wedge-shape bone fragments were minced and re-implanted to the latter osteotomy site. The osteotomized sternum was fixed with multiple wirings. With chondrosternoplasty, a complex chest wall deformity can be corrected successfully. PMID:27298803
A Case of Successful Surgical Repair for Pectus Arcuatum Using Chondrosternoplasty.
Kim, Sang Yoon; Park, Samina; Kim, Eung Rae; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun
2016-06-01
Pectus arcuatum is a rare complex chest wall deformity. A 31-year-old female presented with a severely protruding upper sternum combined with a concave lower sternum. We planned a modified Ravitch-type operation. Through vertical mid-sternal incision, chondrectomies were performed from the second to fifth costal cartilages, saving the perichondrium. Horizontal osteotomy was performed in a wedge shape on the most protruding point, and followed by an additional partial osteotomy at the most concaved point. The harvested wedge-shape bone fragments were minced and re-implanted to the latter osteotomy site. The osteotomized sternum was fixed with multiple wirings. With chondrosternoplasty, a complex chest wall deformity can be corrected successfully.
SU-E-T-75: A Simple Technique for Proton Beam Range Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgdorf, B; Kassaee, A; Garver, E
2015-06-15
Purpose: To develop a measurement-based technique to verify the range of proton beams for quality assurance (QA). Methods: We developed a simple technique to verify the proton beam range with in-house fabricated devices. Two separate devices were fabricated; a clear acrylic rectangular cuboid and a solid polyvinyl chloride (PVC) step wedge. For efficiency in our clinic, we used the rectangular cuboid for double scattering (DS) beams and the step wedge for pencil beam scanning (PBS) beams. These devices were added to our QA phantom to measure dose points along the distal fall-off region (between 80% and 20%) in addition tomore » dose at mid-SOBP (spread out Bragg peak) using a two-dimensional parallel plate chamber array (MatriXX™, IBA Dosimetry, Schwarzenbruck, Germany). This method relies on the fact that the slope of the distal fall-off is linear and does not vary with small changes in energy. Using a multi-layer ionization chamber (Zebra™, IBA Dosimetry), percent depth dose (PDD) curves were measured for our standard daily QA beams. The range (energy) for each beam was then varied (i.e. ±2mm and ±5mm) and additional PDD curves were measured. The distal fall-off of all PDD curves was fit to a linear equation. The distal fall-off measured dose for a particular beam was used in our linear equation to determine the beam range. Results: The linear fit of the fall-off region for the PDD curves, when varying the range by a few millimeters for a specific QA beam, yielded identical slopes. The calculated range based on measured point dose(s) in the fall-off region using the slope resulted in agreement of ±1mm of the expected beam range. Conclusion: We developed a simple technique for accurately verifying the beam range for proton therapy QA programs.« less
Vallespir, Gabriel Pizà; Flores, Jesús Burgos; Trigueros, Ignacio Sanpera; Sierra, Eduardo Hevia; Fernández, Pedro Doménech; Olaverri, Juan Carlos Rodríguez; Alonso, Manuel García; Galea, Rafael Ramos; Francisco, Antonio Pérez; Rodríguez de Paz, Beatriz; Carbonell, Pedro Gutiérrez; Thomas, Javier Vicente; López, José Luís González; Paulino, José Ignacio Maruenda; Pitarque, Carlos Barrios; García, Oscar Riquelme
2008-06-15
Prospective multicentric study. To present the preliminary results of an innovative method for standardized correction of scoliosis, vertebral coplanar alignment (VCA), based on a novel concept: the relocation of vertebral axis in a single plane. Normal standing spine has no rotation in coronal or transverse planes, therefore X and Z axis of vertebrae are in the same plane: they are coplanar. VCA intends to relocate these axis in one plane, correcting rotation and translation, while X axis are returned to its normal posterior divergence in sagittal plane in thoracic spine. Twenty-five consecutive adolescent idiopathic scoliosis patients (Lenke type 1) underwent posterior surgery with segmental pedicle screw fixation. Slotted tubes were attached to convex side screws. Two longitudinal rods were inserted through the end of tubes. Then, they were separated along the slots, driving the tubes into one plane, making the axis of the vertebrae coplanar and thus correcting transverse rotation and coronal translation. To obtain kyphosis, distal ends of the tubes were spread in thoracic spine. Correction was maintained by locking a definitive rod in the concave side, then tubes were retrieved and the convex side rod, inserted and tightened. Correction was assessed on preoperative and postoperative full-spine standing radiograph. Vertebral rotation was measured on computed tomography-scan and magnetic resonance imaging. Preoperative average thoracic curves of 61 degrees were corrected to 16 degrees (73%). Preoperative average thoracolumbar curves of 39 degrees were corrected to 12 degrees (70%). Preoperative average thoracic apical rotation of 24 degrees was corrected to 11 degrees (56%). Preoperative average thoracic kyphosis of 18 degrees remained unchanged after surgery; however, no patients had kyphosis <10 degrees after surgery. Rib hump improved from 30 to 11 mm (65%). There were no perioperative complications. VCA provided excellent correction of coronal and transverse planes with normalization of thoracic kyphosis in Lenke type 1 adolescent idiopathic scoliosis surgery.
Code of Federal Regulations, 2013 CFR
2013-10-01
... feeder link earth stations in the 17/24 GHz BSS. 25.223 Section 25.223 Telecommunication FEDERAL....223 Off-axis EIRP spectral density limits for feeder link earth stations in the 17/24 GHz BSS. (a) This section applies to all applications for earth station licenses in the 17/24 GHz BSS frequency...
Code of Federal Regulations, 2011 CFR
2011-10-01
... feeder link earth stations in the 17/24 GHz BSS. 25.223 Section 25.223 Telecommunication FEDERAL....223 Off-axis EIRP spectral density limits for feeder link earth stations in the 17/24 GHz BSS. (a) This section applies to all applications for earth station licenses in the 17/24 GHz BSS frequency...
Code of Federal Regulations, 2012 CFR
2012-10-01
... feeder link earth stations in the 17/24 GHz BSS. 25.223 Section 25.223 Telecommunication FEDERAL....223 Off-axis EIRP spectral density limits for feeder link earth stations in the 17/24 GHz BSS. (a) This section applies to all applications for earth station licenses in the 17/24 GHz BSS frequency...
Code of Federal Regulations, 2010 CFR
2010-10-01
... feeder link earth stations in the 17/24 GHz BSS. 25.223 Section 25.223 Telecommunication FEDERAL....223 Off-axis EIRP spectral density limits for feeder link earth stations in the 17/24 GHz BSS. (a) This section applies to all applications for earth station licenses in the 17/24 GHz BSS frequency...
Chen, Weitian; Sica, Christopher T; Meyer, Craig H
2008-11-01
Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of correcting for B0 inhomogeneity and concomitant gradients simultaneously. The method is a fast alternative to conjugate phase reconstruction, with the off-resonance phase term approximated by Chebyshev polynomials. The proposed algorithm is well suited for semiautomatic off-resonance correction, which works well even with an inaccurate or low-resolution field map. The proposed algorithm is demonstrated using phantom and in vivo data sets acquired by spiral scanning. Semiautomatic off-resonance correction alone is shown to provide a moderate amount of correction for concomitant gradient field effects, in addition to B0 imhomogeneity effects. However, better correction is provided by the proposed combined method. The best results were produced using the semiautomatic version of the proposed combined method.
On the acoustic wedge design and simulation of anechoic chamber
NASA Astrophysics Data System (ADS)
Jiang, Changyong; Zhang, Shangyu; Huang, Lixi
2016-10-01
This study proposes an alternative to the classic wedge design for anechoic chambers, which is the uniform-then-gradient, flat-wall (UGFW) structure. The working mechanisms of the proposed structure and the traditional wedge are analyzed. It is found that their absorption patterns are different. The parameters of both structures are optimized for achieving minimum absorber depth, under the condition of absorbing 99% of normal incident sound energy. It is found that, the UGFW structure achieves a smaller total depth for the cut-off frequencies ranging from 100 Hz to 250 Hz. This paper also proposes a modification for the complex source image (CSI) model for the empirical simulation of anechoic chambers, originally proposed by Bonfiglio et al. [J. Acoust. Soc. Am. 134 (1), 285-291 (2013)]. The modified CSI model considers the non-locally reactive effect of absorbers at oblique incidence, and the improvement is verified by a full, finite-element simulation of a small chamber. With the modified CSI model, the performance of both decorations with the optimized parameters in a large chamber is simulated. The simulation results are analyzed and checked against the tolerance of 1.5 dB deviation from the inverse square law, stipulated in the ISO standard 3745(2003). In terms of the total decoration depth and anechoic chamber performance, the UGFW structure is better than the classic wedge design.
Refraction of sound by a shear layer - Experimental assessment
NASA Technical Reports Server (NTRS)
Schlinker, R. H.; Amiet, R. K.
1979-01-01
An experimental study was conducted to determine the refraction angle and amplitude changes associated with sound transmission through a circular, open jet shear layer. Both on-axis and off-axis acoustic source locations were used. Source frequency varied from 1 kHz to 10 kHz while freestream Mach number varied from 0.1 to 0.4. The experimental results were compared with an existing refraction theory which was extended to account for off-axis source positions. A simple experiment was also conducted to assess the importance of turbulence scattering between 1 kHz and 25 kHz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bie, B. X.; Huang, J. Y.; Fan, D.
Uniaxial tensile experiments are conducted on a T700 carbon fiber/epoxy composite along various offaxis angles. Stressestrain curves are measured along with strain fields mapped via synchrotron x-ray digital image correlation, as well as computerized tomography. Elastic modulus and tensile strength decrease with increasing off-axis angles, while fracture strain exhibits a nonmonotonic trend as a combined result of tensile strength decrease and fracture mode transition. At high off-axis angles, strain field mapping demonstrates distinct tensile and shear strain localizations and deformation bands approximately along the fiber directions, while deformation is mainly achieved via continuous growth of tensile strain at low off-axismore » angles. Roughness of fracture planes decreases exponentially as the off-axis angle increases. The stressestrain curves, strain fields, tomography and fractographs show consistent features, and reveal a fracture mode transition from mainly tension (fiber fracture) to in-plane shear (interface debonding).« less
Production of Internal Transport Barriers via self-generated flows in Alcator C-Mod
NASA Astrophysics Data System (ADS)
Fiore, Catherine L.
2011-10-01
New results suggest that changes observed in the intrinsic toroidal rotation influence ITB formation in Alcator C-Mod that arise when the resonance for ICRF minority heating is positioned off-axis at or outside of the plasma half-radius. These ITBs form in a reactor relevant regime, without particle or momentum injection, with Ti ~Te, and with monotonic q profiles (qmin < 1). C-Mod H-mode plasmas exhibit strong intrinsic co-current rotation that increases with increasing stored energy without external drive. With the resonance position off-axis, the rotation decreases in the center of the plasma resulting in a radial rotation profile with a central well which deepens and moves farther off-axis when the ICRF resonance is at the plasma half-radius. This profile results in strong ExB shear (>1.5x105 Rad/sec) in the region where the ITB foot is observed. The self generated ExB shearing increases rapidly after the H-mode transition in off-axis ICRF heated discharges, before other profile changes are observed. Gyrokinetic analyses indicate that this spontaneous shearing rate is comparable to the linear ITG growth rate at the ITB location and may be responsible for stabilizing the underlying turbulence. Detailed measurement of the ion temperature demonstrates that the radial profile also flattens as the ICRF resonance position moves off axis. This decreases R/LTi in the barrier region, lessening the drive for the ITG turbulence and the resulting particle transport. The reduction in particle transport resulting from increase in core stability allows the neoclassical pinch to peak the density and pressure on axis. This suggests that spontaneous rotation is a potential tool for plasma profile control in reactor plasmas. The experimental results and corresponding gyrokinetic study will be presented. US-DoE DE-FC02-99ER54512 and DE-FG03-96ER54373.
NASA Astrophysics Data System (ADS)
Maia, M.; Briais, A.; Barrere, F.; Boulart, C.; Ceuleneer, G.; Ferreira, N.; Hanan, B. B.; Hemond, C.; MacLeod, S.; Maillard, A. L.; Merkuryev, S. A.; Park, S. H.; Revillon, S.; Ruellan, E.; Schohn, A.; Watson, S. J.; Yang, Y. S.
2015-12-01
We present observations of the South-East Indian Ridge (SEIR) collected during the STORM cruise (South Tasmania Ocean Ridge and Mantle) on the N/O L'Atalante early 2015. The SEIR between Australia and Antarctica displays large variations of axial morphology despite an almost constant intermediate spreading rate. The Australia-Antarctic Discordance (AAD) between 120°E and 128°E is a section of the mid-ocean ridge where the magma budget is abnormally low, and which marks the boundary between Indian and Pacific mantle domains with distinct geochemical isotopic compositions. The STORM project focuses on the area east of the discordance from 128 to 140°E, where gravity highs observed on satellite-derived maps of the flanks of the SEIR reveal numerous volcanic seamounts. A major objective of the STORM cruise was to test the hypothesis of a mantle flow from the Pacific to the Indian domains. We collected multibeam bathymetry and magnetic data between 136 and 138°E to map off-axis volcanic ridges up to 10 Ma-old crust. We mapped the SEIR axis between 129 and 140°E, and the northern part of the George V transform fault. We collected rock samples on seamounts and in the transform fault, basaltic glass samples along the ridge axis, and near-bottom samples and in-situ measurements in the water column. Our observations reveal that the off-axis seamounts form near the SEIR axis, and are not associated to off-axis deformation of the ocean floor. They show a general shallowing of the ridge axis from the AAD to the George V TF and the presence of robust axial segments near the transform fault. They allow us to describe the complex evolution of the transform fault system. They also permit to locate new hydrothermal systems along the ridge axis. STORM cruise scientific party: F. Barrere, C. Boulart, G. Ceuleneer, N. Ferreira, B. Hanan, C. Hémond, S. Macleod, M. Maia, A. Maillard, S. Merkuryev, S.H. Park, S. Révillon, E. Ruellan, A. Schohn, S. Watson, and Y.S. Yang.
Fos-defined activity in rat brainstem following centripetal acceleration.
Kaufman, G D; Anderson, J H; Beitz, A J
1992-11-01
To identify rat brainstem nuclei involved in the initial, short-term response to a change in gravito-inertial force, adult Long-Evans rats were rotated in the horizontal plane for 90 min in complete darkness after they were eccentrically positioned off the axis of rotation (off-axis) causing a centripetal acceleration of 2 g. Neural activation was defined by the brainstem distribution of the c-fos primary response gene protein, Fos, using immunohistochemistry. The Fos labeling in off-axis animals was compared with that of control animals who were rotated on the axis of rotation (on-axis) with no centripetal acceleration, or who were restrained but not rotated. In the off-axis animals there was a significant labeling of neurons: in the inferior, medial, and y-group subnuclei of the vestibular complex; in subnuclei of the inferior olive, especially the dorsomedial cell column; in midbrain nuclei, including the interstitial nucleus of Cajal, nucleus of Darkschewitsch, Edinger-Westphal nucleus, and dorsolateral periaqueductal gray; in autonomic centers including the solitary nucleus, area postrema, and locus coeruleus; and in reticular nuclei including the lateral reticular nucleus and the lateral parabrachial nucleus. Also, there was greater Fos expression in the dorsomedial cell column, the principal inferior olive subnuclei, inferior vestibular nucleus, the dorsolateral central gray, and the locus coeruleus in animals who had their heads restrained compared to animals whose heads were not restrained. As one control, the vestibular neuroepithelium was destroyed by injecting sodium arsanilate into the middle ear, bilaterally. This resulted in a complete lack of Fos labeling in the vestibular nuclei and the inferior olive, and a significant reduction in labeling in other nuclei in the off-axis condition, indicating that these nuclei have a significant labyrinth-sensitive component to their Fos labeling. The data indicate that several novel brainstem regions, including the dorsomedial cell column of the inferior olive and the periaqueductal gray, as well as more traditional brainstem nuclei including vestibular and oculomotor related nuclei, respond to otolith activation during a sustained centripetal acceleration.
Tsai, Liang-Ching; Ren, Yupeng; Gaebler-Spira, Deborah J; Revivo, Gadi A; Zhang, Li-Qun
2017-07-01
This preliminary study examined the effects of off-axis elliptical training on reducing transverse-plane gait deviations and improving gait function in 8 individuals with cerebral palsy (CP) (15.5 ± 4.1 years) who completed an training program using a custom-made elliptical trainer that allows transverse-plane pivoting of the footplates during exercise. Lower-extremity off-axis control during elliptical exercise was evaluated by quantifying the root-mean-square and maximal angular displacement of the footplate pivoting angle. Lower-extremity pivoting strength was assessed. Gait function and balance were evaluated using 10-m walk test, 6-minute-walk test, and Pediatric Balance Scale. Toe-in angles during gait were quantified. Participants with CP demonstrated a significant decrease in the pivoting angle (root mean square and maximal angular displacement; effect size, 1.00-2.00) and increase in the lower-extremity pivoting strength (effect size = 0.91-1.09) after training. Reduced 10-m walk test time (11.9 ± 3.7 seconds vs. 10.8 ± 3.0 seconds; P = 0.004; effect size = 1.46), increased Pediatric Balance Scale score (43.6 ± 12.9 vs. 45.6 ± 10.8; P = 0.042; effect size = 0.79), and decreased toe-in angle (3.7 ± 10.5 degrees vs. 0.7 ± 11.7 degrees; P = 0.011; effect size = 1.22) were observed after training. We present an intervention to challenge lower-extremity off-axis control during a weight-bearing and functional activity for individuals with CP. Our preliminary findings suggest that this intervention was effective in enhancing off-axis control, gait function, and balance and reducing in-toeing gait in persons with CP.
NASA Astrophysics Data System (ADS)
Kirneva, N. A.; Razumova, K. A.; Pochelon, A.; Behn, R.; Coda, S.; Curchod, L.; Duval, B. P.; Goodman, T. P.; Labit, B.; Karpushov, A. N.; Rancic, M.; Sauter, O.; Silva, M.; TCV Team
2012-01-01
Scenarios with different electron cyclotron heating power profile distributions and widths were compared for the first time in experiments on the Tokamak à Configuration Variable (TCV). The heating profile was changed from shot to shot over a wide range from localized on-axis, with normalized minor radius half-width at half maximum σ1/2 ~ 0.1, up to a widely distributed heating power profile with σ1/2 ~ 0.4 and finally to a profile peaked far off-axis. The global confinement, MHD activity, density, temperature and electron pressure profile evolution were compared. In particular, the energy confinement properties of discharges with localized on-axis heating and distributed on-axis heating were very similar, with degradation close to that predicted by the ITER L-mode scaling; in the case of off-axis heating, on the other hand, the confinement degradation was even stronger.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Francescon, Paolo, E-mail: paolo.francescon@ulssvicenza.it; Satariano, Ninfa; Beddar, Sam
Purpose: Evaluate the ability of different dosimeters to correctly measure the dosimetric parameters percentage depth dose (PDD), tissue-maximum ratio (TMR), and off-axis ratio (OAR) in water for small fields. Methods: Monte Carlo (MC) simulations were used to estimate the variation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} for several types of microdetectors as a function of depth and distance from the central axis for PDD, TMR, and OAR measurements. The variation of k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}more » enables one to evaluate the ability of a detector to reproduce the PDD, TMR, and OAR in water and consequently determine whether it is necessary to apply correction factors. The correctness of the simulations was verified by assessing the ratios between the PDDs and OARs of 5- and 25-mm circular collimators used with a linear accelerator measured with two different types of dosimeters (the PTW 60012 diode and PTW PinPoint 31014 microchamber) and the PDDs and the OARs measured with the Exradin W1 plastic scintillator detector (PSD) and comparing those ratios with the corresponding ratios predicted by the MC simulations. Results: MC simulations reproduced results with acceptable accuracy compared to the experimental results; therefore, MC simulations can be used to successfully predict the behavior of different dosimeters in small fields. The Exradin W1 PSD was the only dosimeter that reproduced the PDDs, TMRs, and OARs in water with high accuracy. With the exception of the EDGE diode, the stereotactic diodes reproduced the PDDs and the TMRs in water with a systematic error of less than 2% at depths of up to 25 cm; however, they produced OAR values that were significantly different from those in water, especially in the tail region (lower than 20% in some cases). The microchambers could be used for PDD measurements for fields greater than those produced using a 10-mm collimator. However, with the detector stem parallel to the beam axis, the microchambers could be used for TMR measurements for all field sizes. The microchambers could not be used for OAR measurements for small fields. Conclusions: Compared with MC simulation, the Exradin W1 PSD can reproduce the PDDs, TMRs, and OARs in water with a high degree of accuracy; thus, the correction used for converting dose is very close to unity. The stereotactic diode is a viable alternative because it shows an acceptable systematic error in the measurement of PDDs and TMRs and a significant underestimation in only the tail region of the OAR measurements, where the dose is low and differences in dose may not be therapeutically meaningful.« less
Visual Costs of the Inhomogeneity of Luminance and Contrast by Viewing LCD-TFT Screens Off-Axis.
Ziefle, Martina; Groeger, Thomas; Sommer, Dietmar
2003-01-01
In this study the anisotropic characteristics of TFT-LCD (Thin-Film-Transistor-Liquid Crystal Display) screens were examined. Anisotropy occurs as the distribution of luminance and contrast changes over the screen surface due to different viewing angles. On the basis of detailed photometric measurements the detection performance in a visual reaction task was measured in different viewing conditions. Viewing angle (0 degrees, frontal view; 30 degrees, off-axis; 50 degrees, off-axis) as well as ambient lighting (a dark or illuminated room) were varied. Reaction times and accuracy of detection performance were recorded. Results showed TFT's anisotropy to be a crucial factor deteriorating performance. With an increasing viewing angle performance decreased. It is concluded that TFT's anisotropy is a limiting factor for overall suitability and usefulness of this new display technology.
A hydrostatic stress-dependent anisotropic model of viscoplasticity
NASA Technical Reports Server (NTRS)
Robinson, D. N.; Tao, Q.; Verrilli, M. J.
1994-01-01
A hydrostatic stress-dependent, anisotropic model of viscoplasticity is formulated as an extension of Bodner's model. This represents a further extension of the isotropic Bodner model over that made to anisotropy by Robinson and MitiKavuma. Account is made of the inelastic deformation that can occur in metallic composites under hydrostatic stress. A procedure for determining the material parameters is identified that is virtually identical to the established characterization procedure for the original Bodner model. Characterization can be achieved using longitudinal/transverse tensile and shear tests and hydrostatic stress tests; alternatively, four off-axis tensile tests can be used. Conditions for a yield stress minimum under off-axis tension are discussed. The model is applied to a W/Cu composite; characterization is made using off-axis tensile data generated at NASA Lewis Research Center (LeRC).
NASA Astrophysics Data System (ADS)
Godin, E.; Fortier, D.
2011-12-01
Thermo-erosion gullies often develop in ice-wedge polygons terrace and contribute to the dynamic evolution of the periglacial landscape. When snowmelt surface run-off concentrated into streams and water tracks infiltrate frost cracks, advective heat flow and convective thermal transfer from water to the ice-wedge ice enable the rapid development of tunnels and gullies in the permafrost (Fortier et al. 2007). Fine scale monitoring of the physical interaction between flowing water and ice rich permafrost had already been studied in a context of thermal erosion of a large river banks in Russia (Costard et al. 2003). Ice wedge polygons thermo-erosion process leading to gullying remains to be physically modelled and quantified. The present paper focus on the fine scale monitoring of thermo-erosion physical parameters both in the field and in laboratory. The physical model in laboratory was elaborated using a fixed block of ice monitored by a linear voltage differential transducer (LVDT) and temperature sensors connected to a logger. A water container with controlled discharge and temperature provided the fluid which flowed over the ice through a hose. Water discharge (Q), water temperature (Tw), ice melting temperature (Ti) and ice ablation rate (Ar) were measured. In laboratory, water at 281 Kelvin (K) flowing on the ice (Ti 273 K) made the ice melt at a rate Ar of 0.002 m min-1, under a continuous discharge of ≈ 8 x 10-7 m3 s-1. In the field, a small channel was dug between a stream and an exposed ice-wedge in a pre-existing active gully, where in 2010 large quantities of near zero snowmelt run-off water contributed to several meters of ice wedge ablation and gully development. Screws were fastened into the ice and a ruler was used to measure the ablation rate every minute. The surface temperature of the ice wedge was monitored with thermocouples connected to a logger to obtain the condition of the ice boundary layer. Discharge and water temperature were measured in the excavated channel just before the water got in contact with the ice surface. The field experiment where flowing water at Tw = 277 K, Ti = 273 K with a water discharge of 0.01 m3 s-1 resulted in a measured Ar of 0.01 to 0.02 m min-1. Water discharge and temperature difference between water and the melting ice were fundamental to ice ablation rate. The recent climate warming in the Canadian High Arctic will likely strongly contribute to the interaction and importance of the thermo-erosion and gullying processes in the High Arctic. Combined factors such as earlier or faster snowmelt, precipitation changes during the summer and positive feedback effects will probably increase the hydrological input to gullies and therefore enhance their development by thermo-erosion. Costard F. et al. 2003. Fluvial thermal erosion investigations along a rapidly eroding river bank: Application to the Lena River (central Siberia). Earth Surface Processes and Landforms 28: 1349-1359. Fortier D. et al. 2007. Observation of rapid drainage system development by thermal erosion of ice wedges on Bylot island, Canadian Arctic Archipelago. Permafrost and Periglacial Processes 18: 229-243.
Publisher Correction: Rotating robots move collectively and self-organize.
Scholz, Christian; Engel, Michael; Pöschel, Thorsten
2018-04-11
The original version of this Article contained an error in Fig. 5. In Fig. 5e, the scale on the y-axis originally incorrectly went from '0' to '1.10 -4 '. The correct scale goes from '0' to '0.4'. In Fig 5f, the x-axis labels were incorrectly shifted to the right. This has been corrected in both the PDF and HTML versions of the Article.
Radius of Curvature of Off-Axis Paraboloids
NASA Technical Reports Server (NTRS)
Robinson, Brian; Reardon, Patrick; Hadaway, James; Geary, Joseph; Russell, Kevin (Technical Monitor)
2002-01-01
We present several methods for measuring the vertex radius of curvature of off-axis paraboloidal mirrors. One is based on least-squares fitting of interferometer output, one on comparison of sagittal and tangential radii of curvature, and another on measurement of displacement of the nulled test article from the ideal reference wave. Each method defines radius of curvature differently and, as a consequence, produces its own sort of errors.
Meehan, John P; Khadder, Mohammad A; Jamali, Amir A; Trauner, Kenneth B
2009-05-01
Posttraumatic osteoarthritis of the knee can be associated with angular deformities and alterations in the joint line as a result of the initial trauma and subsequent surgical procedures. These deformities can be characterized as extra-articular or intra-articular or can involve aspects of both. Conversion to total knee arthroplasty (TKA) may require either a staged or a simultaneous corrective osteotomy to restore the limb alignment and proper knee function. This article describes a closing wedge retrotubercular tibia osteotomy performed concurrently with TKA in an effort to correct an extra-articular varus deformity and to improve the patella tendon height in relation to the reconstructed joint line. A 57-year-old man previously treated for a Schatzker type 6 tibia plateau fracture presented with symptoms of arthritis pain and instability as a result of a varus thrust with weight bearing. Radiographs revealed posttraumatic osteoarthritis, a 35 degrees varus deformity, and patella infera. Maintaining the tibia tubercle continuity with the distal tibia allowed for correction of the varus deformity and improvement in the patella tendon height relative to the joint line. At 5-year follow-up, the patient had osteotomy healing, clinically neutral limb alignment, and improvement in joint line biomechanics with resolution of symptoms of pain and instability.
First metatarsal length change after basilar closing wedge osteotomy for hallux valgus.
Day, Thomas; Charlton, Timothy P; Thordarson, David B
2011-05-01
Hallux valgus deformities with large intermetatarsal angles require a more proximal metatarsal procedure to adequately correct the deformity. Due to the relative ease of a closing wedge osteotomy, this technique was adopted but with concern over first metatarsal shortening. In this study, we primarily evaluated angular correction and first metatarsal shortening. We evaluated 70 feet in 57 patients (average age, 54 years) with 52 female and five male. The average followup was 14 (range, 6 to 45) months. The charts were reviewed for the presence of metatarsalgia. Digital radiographic measurements were made for pre- and postoperative hallux valgus and intermetatarsal angles, dorsiflexion angle of the first metatarsal, and absolute and relative shortening of the first metatarsal. The average hallux valgus angle improved from 31 to 11 degrees (p < 0.0001) and intermetatarsal angle from 13.2 to 4.4 angles (p < 0.0001). The absolute shortening of the first metatarsal was 2.2 mm and relative shortening was 0.6 mm. There was 1.3 degrees of dorsiflexion on average. Excellent correction of the deformity with minimal dorsiflexion or new complaints of metatarsalgia was found with this technique. The new method of assessing the relative shortening found to be less than the absolute shortening, which we feel more accurately reflects the functional length of the first metatarsal.
LC-lens array with light field algorithm for 3D biomedical applications
NASA Astrophysics Data System (ADS)
Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun
2016-03-01
In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.
Modeling of polychromatic attenuation using computed tomography reconstructed images
NASA Technical Reports Server (NTRS)
Yan, C. H.; Whalen, R. T.; Beaupre, G. S.; Yen, S. Y.; Napel, S.
1999-01-01
This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.
A novel and fast method for proton range verification using a step wedge and 2D scintillator.
Shen, Jiajian; Allred, Bryce C; Robertson, Daniel G; Liu, Wei; Sio, Terence T; Remmes, Nicholas B; Keole, Sameer R; Bues, Martin
2017-09-01
To implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge. A homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge. The range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements. A novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible. © 2017 American Association of Physicists in Medicine.
RANS Analyses of Turbofan Nozzles with Internal Wedge Deflectors for Noise Reduction
NASA Technical Reports Server (NTRS)
DeBonis, James R.
2009-01-01
Computational fluid dynamics (CFD) was used to evaluate the flow field and thrust performance of a promising concept for reducing the noise at take-off of dual-stream turbofan nozzles. The concept, offset stream technology, reduces the jet noise observed on the ground by diverting (offsetting) a portion of the fan flow below the core flow, thickening and lengthening this layer between the high-velocity core flow and the ground observers. In this study a wedge placed in the internal fan stream is used as the diverter. Wind, a Reynolds averaged Navier-Stokes (RANS) code, was used to analyze the flow field of the exhaust plume and to calculate nozzle performance. Results showed that the wedge diverts all of the fan flow to the lower side of the nozzle, and the turbulent kinetic energy on the observer side of the nozzle is reduced. This reduction in turbulent kinetic energy should correspond to a reduction in noise. However, because all of the fan flow is diverted, the upper portion of the core flow is exposed to the freestream, and the turbulent kinetic energy on the upper side of the nozzle is increased, creating an unintended noise source. The blockage due to the wedge reduces the fan mass flow proportional to its blockage, and the overall thrust is consequently reduced. The CFD predictions are in very good agreement with experimental flow field data, demonstrating that RANS CFD can accurately predict the velocity and turbulent kinetic energy fields. While this initial design of a large scale wedge nozzle did not meet noise reduction or thrust goals, this study identified areas for improvement and demonstrated that RANS CFD can be used to improve the concept.
Axisymmetric Implementation for 3D-Based DSMC Codes
NASA Technical Reports Server (NTRS)
Stewart, Benedicte; Lumpkin, F. E.; LeBeau, G. J.
2011-01-01
The primary objective in developing NASA s DSMC Analysis Code (DAC) was to provide a high fidelity modeling tool for 3D rarefied flows such as vacuum plume impingement and hypersonic re-entry flows [1]. The initial implementation has been expanded over time to offer other capabilities including a novel axisymmetric implementation. Because of the inherently 3D nature of DAC, this axisymmetric implementation uses a 3D Cartesian domain and 3D surfaces. Molecules are moved in all three dimensions but their movements are limited by physical walls to a small wedge centered on the plane of symmetry (Figure 1). Unfortunately, far from the axis of symmetry, the cell size in the direction perpendicular to the plane of symmetry (the Z-direction) may become large compared to the flow mean free path. This frequently results in inaccuracies in these regions of the domain. A new axisymmetric implementation is presented which aims to solve this issue by using Bird s approach for the molecular movement while preserving the 3D nature of the DAC software [2]. First, the computational domain is similar to that previously used such that a wedge must still be used to define the inflow surface and solid walls within the domain. As before molecules are created inside the inflow wedge triangles but they are now rotated back to the symmetry plane. During the move step, molecules are moved in 3D but instead of interacting with the wedge walls, the molecules are rotated back to the plane of symmetry at the end of the move step. This new implementation was tested for multiple flows over axisymmetric shapes, including a sphere, a cone, a double cone and a hollow cylinder. Comparisons to previous DSMC solutions and experiments, when available, are made.
Chen, Weitian; Sica, Christopher T.; Meyer, Craig H.
2008-01-01
Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of correcting for B0 inhomogeneity and concomitant gradients simultaneously. The method is a fast alternative to conjugate phase reconstruction, with the off-resonance phase term approximated by Chebyshev polynomials. The proposed algorithm is well suited for semiautomatic off-resonance correction, which works well even with an inaccurate or low-resolution field map. The proposed algorithm is demonstrated using phantom and in vivo data sets acquired by spiral scanning. Semiautomatic off-resonance correction alone is shown to provide a moderate amount of correction for concomitant gradient field effects, in addition to B0 imhomogeneity effects. However, better correction is provided by the proposed combined method. The best results were produced using the semiautomatic version of the proposed combined method. PMID:18956462
Han, Myung-Geun; Garlow, Joseph A.; Marshall, Matthew S. J.; ...
2017-03-23
The ability to map out electrostatic potentials in materials is critical for the development and the design of nanoscale electronic and spintronic devices in modern industry. Electron holography has been an important tool for revealing electric and magnetic field distributions in microelectronics and magnetic-based memory devices, however, its utility is hindered by several practical constraints, such as charging artifacts and limitations in sensitivity and in field of view. In this article, we report electron-beam-induced-current (EBIC) and secondary-electron voltage-contrast (SE-VC) with an aberration-corrected electron probe in a transmission electron microscope (TEM), as complementary techniques to electron holography, to measure electric fieldsmore » and surface potentials, respectively. These two techniques were applied to ferroelectric thin films, multiferroic nanowires, and single crystals. Electrostatic potential maps obtained by off-axis electron holography were compared with EBIC and SE-VC to show that these techniques can be used as a complementary approach to validate quantitative results obtained from electron holography analysis.« less
First faint dual-field off-axis observations in optical long baseline interferometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woillez, J.; Wizinowich, P.; Ragland, S.
2014-03-10
Ground-based long baseline interferometers have long been limited in sensitivity in part by the short integration periods imposed by atmospheric turbulence. The first observation fainter than this limit was performed on 2011 January 22 when the Keck Interferometer observed a K = 11.5 target, about 1 mag fainter than its K = 10.3 atmospherically imposed limit; the currently demonstrated limit is K = 12.5. These observations were made possible by the Dual-Field Phase-Referencing (DFPR) instrument, part of the NSF-funded ASTrometry and phase-Referenced Astronomy project; integration times longer than the turbulence time scale are made possible by its ability to simultaneouslymore » measure the real-time effects of the atmosphere on a nearby bright guide star and correct for it on the faint target. We present the implementation of DFPR on the Keck Interferometer. Then, we detail its on-sky performance focusing on the accuracy of the turbulence correction and the resulting fringe contrast stability.« less
Driver-witness electron beam acceleration in dielectric mm-scale capillaries
NASA Astrophysics Data System (ADS)
Lekomtsev, K.; Aryshev, A.; Tishchenko, A. A.; Shevelev, M.; Lyapin, A.; Boogert, S.; Karataev, P.; Terunuma, N.; Urakawa, J.
2018-05-01
We investigated a corrugated mm-scale capillary as a compact accelerating structure in the driver-witness acceleration scheme, and suggested a methodology to measure the acceleration of the witness bunch. The accelerating fields produced by the driver bunch and the energy spread of the witness bunch in a corrugated capillary and in a capillary with a constant inner radius were measured and simulated for both on-axis and off-axis beam propagation. Our simulations predicted a change in the accelerating field structure for the corrugated capillary. Also, an approximately twofold increase of the witness bunch energy gain on the first accelerating cycle was expected for both capillaries for the off-axis beam propagation. These results were confirmed in the experiment, and the maximum measured acceleration of 170 keV /m at 20 pC driver beam charge was achieved for off-axis beam propagation. The driver bunch showed an increase in energy spread of up to 11%, depending on the capillary geometry and beam propagation, with a suppression of the longitudinal energy spread in the witness bunch of up to 15%.
Zheng, Changlin; Zhu, Ye; Lazar, Sorin; Etheridge, Joanne
2014-04-25
We introduce off-axis chromatic scanning confocal electron microscopy, a technique for fast mapping of inelastically scattered electrons in a scanning transmission electron microscope without a spectrometer. The off-axis confocal mode enables the inelastically scattered electrons to be chromatically dispersed both parallel and perpendicular to the optic axis. This enables electrons with different energy losses to be separated and detected in the image plane, enabling efficient energy filtering in a confocal mode with an integrating detector. We describe the experimental configuration and demonstrate the method with nanoscale core-loss chemical mapping of silver (M4,5) in an aluminium-silver alloy and atomic scale imaging of the low intensity core-loss La (M4,5@840 eV) signal in LaB6. Scan rates up to 2 orders of magnitude faster than conventional methods were used, enabling a corresponding reduction in radiation dose and increase in the field of view. If coupled with the enhanced depth and lateral resolution of the incoherent confocal configuration, this offers an approach for nanoscale three-dimensional chemical mapping.
The role of turbulent suppression in the triggering ITBs on C-Mod
NASA Astrophysics Data System (ADS)
Zhurovich, K.; Fiore, C. L.; Ernst, D. R.; Bonoli, P. T.; Greenwald, M. J.; Hubbard, A. E.; Hughes, J. W.; Marmar, E. S.; Mikkelsen, D. R.; Phillips, P.; Rice, J. E.
2007-11-01
Internal transport barriers can be routinely produced in C-Mod steady EDA H-mode plasmas by applying ICRF at |r/a|>= 0.5. Access to the off-axis ICRF heated ITBs may be understood within the paradigm of marginal stability. Analysis of the Te profiles shows a decrease of R/LTe in the ITB region as the RF resonance is moved off axis. Ti profiles broaden as the ICRF power deposition changes from on-axis to off-axis. TRANSP calculations of the Ti profiles support this trend. Linear GS2 calculations do not reveal any difference in ETG growth rate profiles for ITB vs. non-ITB discharges. However, they do show that the region of stability to ITG modes widens as the ICRF resonance is moved outward. Non-linear simulations show that the outward turbulent particle flux exceeds the Ware pinch by factor of 2 in the outer plasma region. Reducing the temperature gradient significantly decreases the diffusive flux and allows the Ware pinch to peak the density profile. Details of these experiments and simulations will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferguson, S; Ahmad, S; Chen, Y
2016-06-15
Purpose: To commission and investigate the accuracy of an output (cGy/MU) prediction model for a compact passively scattered proton therapy system. Methods: A previously published output prediction model (Sahoo et al, Med Phys, 35, 5088–5097, 2008) was commissioned for our Mevion S250 proton therapy system. This model is a correction-based model that multiplies correction factors (d/MUwnc=ROFxSOBPF xRSFxSOBPOCFxOCRxFSFxISF). These factors accounted for changes in output due to options (12 large, 5 deep, and 7 small), modulation width M, range R, off-center, off-axis, field-size, and off-isocenter. In this study, the model was modified to ROFxSOBPFxRSFxOCRxFSFxISF-OCFxGACF by merging SOBPOCF and ISF for simplicitymore » and introducing a gantry angle correction factor (GACF). To commission the model, outputs over 1,000 data points were taken at the time of the system commissioning. The output was predicted by interpolation (1D for SOBPF, FSF, and GACF; 2D for RSF and OCR) with inverse-square calculation (ISF-OCR). The outputs of 273 combinations of R and M covering total 24 options were measured to test the model. To minimize fluence perturbation, scattered dose from range compensator and patient was not considered. The percent differences between the predicted (P) and measured (M) outputs were calculated to test the prediction accuracy ([P-M]/Mx100%). Results: GACF was required because of up to 3.5% output variation dependence on the gantry angle. A 2D interpolation was required for OCR because the dose distribution was not radially symmetric especially for the deep options. The average percent differences were −0.03±0.98% (mean±SD) and the differences of all the measurements fell within ±3%. Conclusion: It is concluded that the model can be clinically used for the compact passively scattered proton therapy system. However, great care should be taken when the field-size is less than 5×5 cm{sup 2} where a direct output measurement is required due to substantial output change by irregular block shape.« less
NASA Astrophysics Data System (ADS)
Pires, Marcelo A.; Crokidakis, Nuno
2017-09-01
The authors regret to inform that there are two misprints in the axis of Fig. 3 of the paper. In Fig. 3(c), the correct identification of the x-axis is γ (gamma) instead of λ (lambda), and in Fig. 3(d), the correct identification of the y-axis is γ (gamma) instead of λ (lambda). These modifications do not affect the results of the paper, as well as the discussion made in the text.
Sample size determination for GEE analyses of stepped wedge cluster randomized trials.
Li, Fan; Turner, Elizabeth L; Preisser, John S
2018-06-19
In stepped wedge cluster randomized trials, intact clusters of individuals switch from control to intervention from a randomly assigned period onwards. Such trials are becoming increasingly popular in health services research. When a closed cohort is recruited from each cluster for longitudinal follow-up, proper sample size calculation should account for three distinct types of intraclass correlations: the within-period, the inter-period, and the within-individual correlations. Setting the latter two correlation parameters to be equal accommodates cross-sectional designs. We propose sample size procedures for continuous and binary responses within the framework of generalized estimating equations that employ a block exchangeable within-cluster correlation structure defined from the distinct correlation types. For continuous responses, we show that the intraclass correlations affect power only through two eigenvalues of the correlation matrix. We demonstrate that analytical power agrees well with simulated power for as few as eight clusters, when data are analyzed using bias-corrected estimating equations for the correlation parameters concurrently with a bias-corrected sandwich variance estimator. © 2018, The International Biometric Society.
NASA Technical Reports Server (NTRS)
Myrick, Thomas M. (Inventor)
2003-01-01
A mechanism for breaking off and retaining a core sample of a drill drilled into a ground substrate has an outer drill tube and an inner core break-off tube sleeved inside the drill tube. The break-off tube breaks off and retains the core sample by a varying geometric relationship of inner and outer diameters with the drill tube. The inside diameter (ID) of the drill tube is offset by a given amount with respect to its outer diameter (OD). Similarly, the outside diameter (OD) of the break-off tube is offset by the same amount with respect to its inner diameter (ID). When the break-off tube and drill tube are in one rotational alignment, the two offsets cancel each other such that the drill can operate the two tubes together in alignment with the drill axis. When the tubes are rotated 180 degrees to another positional alignment, the two offsets add together causing the core sample in the break-off tube to be displaced from the drill axis and applying shear forces to break off the core sample.
Production of 8.4m segments for the Giant Magellan Telescope
NASA Astrophysics Data System (ADS)
Martin, H. M.; Allen, R. G.; Burge, J. H.; Kim, D. W.; Kingsley, J. S.; Law, K.; Lutz, R. D.; Strittmatter, P. A.; Su, P.; Tuell, M. T.; West, S. C.; Zhou, P.
2012-09-01
Production of segments for the Giant Magellan Telescope is well underway at the Steward Observatory Mirror Lab. We report on the completion of the first 8.4 m off-axis segment, the casting of the second segment, and preparations for manufacture of the remaining segments. The complete set of infrastructure for serial production is in place, including the casting furnace, two 8.4 m capacity grinding and polishing machines, and a 28 m test tower that incorporates four independent measurement systems. The first segment, with 14 mm p-v aspheric departure, is by some measures the most challenging astronomical mirror ever made. Its manufacture took longer than expected, but the result is an excellent figure and demonstration of valuable new systems that will support both fabrication and measurement of the remaining segments. Polishing was done with a 1.2 m stressed lap for smoothing and large-scale figuring, and a series of smaller passive rigid-conformal laps for deterministic figuring on smaller scales. The interferometric measurement produces a null wavefront with a 3-element asymmetric null corrector including a 3.8 m spherical mirror and a computer-generated hologram. In addition to this test, we relied heavily on the new SCOTS slope test with its high accuracy and dynamic range. Evaluation of the measured figure includes simulated active correction using both the 160-actuator mirror support and the alignment degrees of freedom for the off-axis segment.
Conformal Stereotactic Radiosurgery With Multileaf Collimation.
1992-01-01
Hartmann, W. Schlegel, V. Sturm, B. Kober, 0. Pastyr, W.J. Lorenz, "Cerebral radiation surgery using moving field irradiation at a linear ac ...Kober, 0. Pastyr, W.J. Lorenz, "Cerebral radiation surgery using moving field irradiation at a linear ac - celerator facility," Int. J. Radiation...scattered photons), off-axis ratios (for points off of the central axis of the incident beam), percent depth dose or tissue maximum ratio (to ac - count for
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1978-01-01
The mechanical behavior and stresses inducing fracture modes of unidirectional high-modulus graphite-fiber/epoxy composites subjected to off-axis tensile loads were investigated theoretically. The investigation included the use of composite mechanics, combined-stress failure criteria, and finite-element stress analysis. The results are compared with experimental data and led to the formulation of criteria and convenient plotting procedures for identifying, characterizing, and quantifying these fracture modes.
Fabrication, Testing, Coating and Alignment of Fast Segmented Optics
2006-05-25
mirror segment, a 100 mm thick Zerodur mirror blank was purchased from Schott. Figure 2 shows the segment and its support for polishing and testing in...Polishing large off-axis segments of fast primary mirrors 2. Testing large segments in an off-axis geometry 3. Alignment of multiple segments of a large... mirror 4. Coatings that reflect high-intensity light without distorting the substrate These technologies are critical because of several unique
Thin glass shells for AO: from plano to off-axis aspherics
NASA Astrophysics Data System (ADS)
Harel, Emmanuelle; Anretar, Alain; Antelme, Jean-Pierre; Caillon, Stéphane; Dussourd, Adrien; Foucaud, Guillaume; Jaury, Hervé; Roure, Océane; William, Jean-Philippe; Wuillaume, Philippe; Ruch, Eric; Geyl, Roland
2016-07-01
Reosc has been working on thin glass shells for many years and was recently selected by ESO for the production of the E-ELT M4 mirror thin glass shells. Previously Reosc also produced the aspheric thin shell for the VLT-M2 AO Facility. Based on this experience we will discuss how off axis thin glass shells can be made for the next generation AO systems like the GMT one.
Off-axis impact of unidirectional composites with cracks: Dynamic stress intensification
NASA Technical Reports Server (NTRS)
Sih, G. C.; Chen, E. P.
1979-01-01
The dynamic response of unidirectional composites under off axis (angle loading) impact is analyzed by assuming that the composite contains an initial flaw in the matrix material. The analytical method utilizes Fourier transform for the space variable and Laplace transform for the time variable. The off axis impact is separated into two parts, one being symmetric and the other skew-symmetric with reference to the crack plane. Transient boundary conditions of normal and shear tractions are applied to a crack embedded in the matrix of the unidirectional composite. The two boundary conditions are solved independently and the results superimposed. Mathematically, these conditions reduce the problem to a system of dual integral equations which are solved in the Laplace transform plane for the transformation of the dynamic stress intensity factor. The time inversion is carried out numerically for various combinations of the material properties of the composite and the results are displayed graphically.
Ten deg off-axis tensile test for intralaminar shear characterization of fiber composites
NASA Technical Reports Server (NTRS)
Chamis, C. C.; Sinclair, J. H.
1976-01-01
A combined theoretical and experimental investigation was conducted to assess the suitability of the 10 deg off-axis tensile test specimen for the intralaminar shear characterization of unidirectional composites. Composite mechanics, a combined-stress failure criterion, and a finite element analysis were used to determine theoretically the stress-strain variation across the specimen width and the relative stress and strain magnitudes at the 10 deg plane. Strain gages were used to measure the strain variation across the specimen width at specimen midlength and near the end tabs. Specimens from Mod-I/epoxy, T-300/epoxy, and S-glass/epoxy were used in the experimental program. It was found that the 10 deg off-axis tensile test specimen is suitable for intralaminar shear characterization and it is recommended that it should be considered as a possible standard test specimen for such a characterization.
NASA Technical Reports Server (NTRS)
Wood, Scott J.; Paloski, W. H. (Principal Investigator)
2002-01-01
The purpose of this study was to examine how the modulation of tilt and translation otolith-ocular responses during constant velocity off-vertical axis rotation varies as a function of stimulus frequency. Eighteen human subjects were rotated in darkness about their longitudinal axis 30 degrees off-vertical at stimulus frequencies between 0.05 and 0.8 Hz. The modulation of torsion decreased while the modulation of horizontal slow phase velocity (SPV) increased with increasing frequency. It is inferred that the ambiguity of otolith afferent information is greatest in the frequency region where tilt (torsion) and translational (horizontal SPV) otolith-ocular responses crossover. It is postulated that the previously demonstrated peak in motion sickness susceptibility during linear accelerations around 0.3 Hz is the result of frequency segregation of ambiguous otolith information being inadequate to distinguish between tilt and translation.
A dual-porosity reactive-transport model of off-axis hydrothermal systems
NASA Astrophysics Data System (ADS)
Farahat, N. X.; Abbot, D. S.; Archer, D. E.
2017-12-01
We built a dual-porosity reactive-transport 2D numerical model of off-axis pillow basalt alteration. An "outer chamber" full of porous glassy material supports significant seawater flushing, and an "inner chamber", which represents the more crystalline interior of a pillow, supports diffusive alteration. Hydrothermal fluids in the two chambers interact, and the two chambers are coupled to 2D flows. In a few million years of low-temperature alteration, the dual-porosity model predicts progressive stages of alteration that have been observed in drilled crust. A single-porosity model, with all else being equal, does not predict alteration stages as well. The dual-chamber model also does a better job than the single-chamber model at predicting the types of minerals expected in off-axis environments. We validate the model's ability to reproduce observations by configuring it to represent a thoroughly-studied transect of the Juan de Fuca Ridge eastern flank.
Shen, Yijie; Meng, Yuan; Fu, Xing; Gong, Mali
2018-01-15
A dual-off-axis pumping scheme is presented to generate wavelength-tunable high-order Hermite-Gaussian (HG) modes in Yb:CaGdAlO 4 lasers. The mode and wavelength can be actively controlled by the off-axis displacements and pump power. The purities of the output HG modes are quantified by intensity distributions and the measured M 2 values. The highest order reaches m=15 for stable HG m,0 mode, and wavelength-tunable width is about 10 nm. Moreover, through externally converting the HG m,0 modes, the vortex beams carrying orbital angular momentum (OAM) with a large OAM-tunable range from ±1ℏ to ±15ℏ are produced. This work is effective for largely scaling the spectral and OAM tunable ranges of optical vortex beams.
Parallel-quadrature phase-shifting digital holographic microscopy using polarization beam splitter
Das, Bhargab; Yelleswarapu, Chandra S; Rao, DVGLN
2012-01-01
We present a digital holography microscopy technique based on parallel-quadrature phase-shifting method. Two π/2 phase-shifted holograms are recorded simultaneously using polarization phase-shifting principle, slightly off-axis recording geometry, and two identical CCD sensors. The parallel phase-shifting is realized by combining circularly polarized object beam with a 45° degree polarized reference beam through a polarizing beam splitter. DC term is eliminated by subtracting the two holograms from each other and the object information is reconstructed after selecting the frequency spectrum of the real image. Both amplitude and phase object reconstruction results are presented. Simultaneous recording eliminates phase errors caused by mechanical vibrations and air turbulences. The slightly off-axis recording geometry with phase-shifting allows a much larger dimension of the spatial filter for reconstruction of the object information. This leads to better reconstruction capability than traditional off-axis holography. PMID:23109732
Fast reconstruction of off-axis digital holograms based on digital spatial multiplexing.
Sha, Bei; Liu, Xuan; Ge, Xiao-Lu; Guo, Cheng-Shan
2014-09-22
A method for fast reconstruction of off-axis digital holograms based on digital multiplexing algorithm is proposed. Instead of the existed angular multiplexing (AM), the new method utilizes a spatial multiplexing (SM) algorithm, in which four off-axis holograms recorded in sequence are synthesized into one SM function through multiplying each hologram with a tilted plane wave and then adding them up. In comparison with the conventional methods, the SM algorithm simplifies two-dimensional (2-D) Fourier transforms (FTs) of four N*N arrays into a 1.25-D FTs of one N*N arrays. Experimental results demonstrate that, using the SM algorithm, the computational efficiency can be improved and the reconstructed wavefronts keep the same quality as those retrieved based on the existed AM method. This algorithm may be useful in design of a fast preview system of dynamic wavefront imaging in digital holography.
Averaging scheme for atomic resolution off-axis electron holograms.
Niermann, T; Lehmann, M
2014-08-01
All micrographs are limited by shot-noise, which is intrinsic to the detection process of electrons. For beam insensitive specimen this limitation can in principle easily be circumvented by prolonged exposure times. However, in the high-resolution regime several instrumental instabilities limit the applicable exposure time. Particularly in the case of off-axis holography the holograms are highly sensitive to the position and voltage of the electron-optical biprism. We present a novel reconstruction algorithm to average series of off-axis holograms while compensating for specimen drift, biprism drift, drift of biprism voltage, and drift of defocus, which all might cause problematic changes from exposure to exposure. We show an application of the algorithm utilizing also the possibilities of double biprism holography, which results in a high quality exit-wave reconstruction with 75 pm resolution at a very high signal-to-noise ratio. Copyright © 2014 Elsevier Ltd. All rights reserved.
Design of off-axis four-mirror optical system without obscuration based on free-form surface
NASA Astrophysics Data System (ADS)
Huang, Chenxu; Liu, Xin
2015-11-01
With the development of modern military technology, the requirements of airborne electro-optical search and tracking system are increasing on target detection and recognition. However, traditional off-axis three-mirror system couldn't meet the requirements for reducing weight and compacting size in some circumstances. Based on Seidel aberration theory, by restricting the aberration functions, the optical system could achieve initial construction parameters. During the designing process, decenters and tilts of mirrors were adjusted continuously to eliminate the obscurations. To balance off-axis aberration and increase angle of view, the free-form mirror was introduced into the optical system. Then an unobstructed optical system with effective focal length of 100 mm, FOV of 16°×16°, and relative aperture as F/7 is designed. The results show that the system structure is compact, with imaging qualities approaching diffraction limit.
Optics ellipticity performance of an unobscured off-axis space telescope.
Zeng, Fei; Zhang, Xin; Zhang, Jianping; Shi, Guangwei; Wu, Hongbo
2014-10-20
With the development of astronomy, more and more attention is paid to the survey of dark matter. Dark matter cannot be seen directly but can be detected by weak gravitational lensing measurement. Ellipticity is an important parameter used to define the shape of a galaxy. Galaxy ellipticity changes with weak gravitational lensing and nonideal optics. With our design of an unobscured off-axis telescope, we implement the simulation and calculation of optics ellipticity. With an accurate model of optics PSF, the characteristic of ellipticity is modeled and analyzed. It is shown that with good optical design, the full field ellipticity can be quite small. The spatial ellipticity change can be modeled by cubic interpolation with very high accuracy. We also modeled the ellipticity variance with time and analyzed the tolerance. It is shown that the unobscured off-axis telescope has good ellipticity performance and fulfills the requirement of dark matter survey.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grierson, B. A.; Wang, W. X.; Ethier, S.
Intrinsic toroidal rotation of the deuterium main ions in the core of the DIII-D tokamak is observed to transition from flat to hollow, forming an off-axis peak, above a threshold level of direct electron heating. Nonlinear gyrokinetic simulations show that the residual stress associated with electrostatic ion temperature gradient turbulence possesses the correct radial location and stress structure to cause the observed hollow rotation profile. Residual stress momentum flux in the gyrokinetic simulations is balanced by turbulent momentum diffusion, with negligible contributions from turbulent pinch. Finally, the prediction of the velocity profile by integrating the momentum balance equation produces amore » rotation profile that qualitatively and quantitatively agrees with the measured main-ion profile, demonstrating that fluctuation-induced residual stress can drive the observed intrinsic velocity profile.« less
Chauvin, K McManus; Asner, G P; Martin, R E; Kress, W J; Wright, S J; Field, C B
2018-03-01
Trade-offs among plant functional traits indicate diversity in plant strategies of growth and survival. The leaf economics spectrum (LES) reflects a trade-off between short-term carbon gain and long-term leaf persistence. A related trade-off, between foliar growth and anti-herbivore defense, occurs among plants growing in contrasting resource regimes, but it is unclear whether this trade-off is maintained within plant communities, where resource gradients are minimized. The LES and the growth-defense trade-off involve related traits, but the extent to which these trade-off dimensions are correlated is poorly understood. We assessed the relationship between leaf economic and anti-herbivore defense traits among sunlit foliage of 345 canopy trees in 83 species on Barro Colorado Island, Panama. We quantified ten traits related to resource allocation and defense, and identified patterns of trait co-variation using multivariate ordination. We tested whether traits and ordination axes were correlated with patterns of phylogenetic relatedness, juvenile demographic trade-offs, or topo-edaphic variation. Two independent axes described ~ 60% of the variation among canopy trees. Axis 1 revealed a trade-off between leaf nutritional and structural investment, consistent with the LES. Physical defense traits were largely oriented along this axis. Axis 2 revealed a trade-off between investments in phenolic defenses versus other foliar defenses, which we term the leaf defense spectrum. Phylogenetic relationships and topo-edaphic variation largely did not explain trait co-variation. Our results suggest that some trade-offs among the growth and defense traits of outer-canopy trees may be captured by the LES, while others may occur along additional resource allocation dimensions.
Errors in radiation oncology: A study in pathways and dosimetric impact
Drzymala, Robert E.; Purdy, James A.; Michalski, Jeff
2005-01-01
As complexity for treating patients increases, so does the risk of error. Some publications have suggested that record and verify (R&V) systems may contribute in propagating errors. Direct data transfer has the potential to eliminate most, but not all, errors. And although the dosimetric consequences may be obvious in some cases, a detailed study does not exist. In this effort, we examined potential errors in terms of scenarios, pathways of occurrence, and dosimetry. Our goal was to prioritize error prevention according to likelihood of event and dosimetric impact. For conventional photon treatments, we investigated errors of incorrect source‐to‐surface distance (SSD), energy, omitted wedge (physical, dynamic, or universal) or compensating filter, incorrect wedge or compensating filter orientation, improper rotational rate for arc therapy, and geometrical misses due to incorrect gantry, collimator or table angle, reversed field settings, and setup errors. For electron beam therapy, errors investigated included incorrect energy, incorrect SSD, along with geometric misses. For special procedures we examined errors for total body irradiation (TBI, incorrect field size, dose rate, treatment distance) and LINAC radiosurgery (incorrect collimation setting, incorrect rotational parameters). Likelihood of error was determined and subsequently rated according to our history of detecting such errors. Dosimetric evaluation was conducted by using dosimetric data, treatment plans, or measurements. We found geometric misses to have the highest error probability. They most often occurred due to improper setup via coordinate shift errors or incorrect field shaping. The dosimetric impact is unique for each case and depends on the proportion of fields in error and volume mistreated. These errors were short‐lived due to rapid detection via port films. The most significant dosimetric error was related to a reversed wedge direction. This may occur due to incorrect collimator angle or wedge orientation. For parallel‐opposed 60° wedge fields, this error could be as high as 80% to a point off‐axis. Other examples of dosimetric impact included the following: SSD, ~2%/cm for photons or electrons; photon energy (6 MV vs. 18 MV), on average 16% depending on depth, electron energy, ~0.5cm of depth coverage per MeV (mega‐electron volt). Of these examples, incorrect distances were most likely but rapidly detected by in vivo dosimetry. Errors were categorized by occurrence rate, methods and timing of detection, longevity, and dosimetric impact. Solutions were devised according to these criteria. To date, no one has studied the dosimetric impact of global errors in radiation oncology. Although there is heightened awareness that with increased use of ancillary devices and automation, there must be a parallel increase in quality check systems and processes, errors do and will continue to occur. This study has helped us identify and prioritize potential errors in our clinic according to frequency and dosimetric impact. For example, to reduce the use of an incorrect wedge direction, our clinic employs off‐axis in vivo dosimetry. To avoid a treatment distance setup error, we use both vertical table settings and optical distance indicator (ODI) values to properly set up fields. As R&V systems become more automated, more accurate and efficient data transfer will occur. This will require further analysis. Finally, we have begun examining potential intensity‐modulated radiation therapy (IMRT) errors according to the same criteria. PACS numbers: 87.53.Xd, 87.53.St PMID:16143793
NASA Astrophysics Data System (ADS)
Belen'kii, Mikhail S.; Rye, Vincent; Runyeon, Hope
2007-09-01
A concept of a Hybrid Wavefront-based Stochastic Parallel Gradient Decent (WSPGD) Adaptive Optics (AO) system for correcting the combined effects of Beacon Anisoplanatism and Thermal Blooming is introduced. This system integrates a conventional phase conjugate (PC) AO system with a WSPGD AO system. It uses on-axis wavefront measurements of a laser return from an extended beacon to generate initial deformable mirror (DM) commands. Since high frequency phase components are removed from the wavefront of a laser return by a low-pass filter effect of an extended beacon, the system also uses off-axis wavefront measurements to provide feedback for a multi-dithering beam control algorithm in order to generate additional DM commands that account for those missing high frequency phase components. Performance of the Hybrid WSPGD AO system was evaluated in simulation using a wave optics code. Numerical analysis was performed for two tactical scenarios that included ranges of L = 2 km and L = 20 km, ratio of aperture diameter to Fried parameter, D/r 0, of up to 15, ratio of beam spot size at the target to isoplanatic angle, θ B/θ 0, of up to 40, and general distortion number characterizing the strength of Thermal Blooming, N d = 50, 75, and 100. A line-of-sight in the corrected beam was stabilized using a target-plane tracker. The simulation results reveal that the Hybrid WSPGD AO system can efficiently correct the effects of Beacon Anisoplanatism and Thermal Blooming, providing improved compensation of Thermal Blooming in the presence of strong turbulence. Simulation results also indicate that the Hybrid WSPGD AO system outperforms a conventional PC AO system, increasing the Strehl ratio by up to 300% in less than 50 iterations. A follow-on laboratory demonstration performed under a separate program confirmed our theoretical predictions.
Lárraga-Gutiérrez, José Manuel; Ballesteros-Zebadúa, Paola; Rodríguez-Ponce, Miguel; García-Garduño, Olivia Amanda; de la Cruz, Olga Olinca Galván
2015-01-21
A CVD based radiation detector has recently become commercially available from the manufacturer PTW-Freiburg (Germany). This detector has a sensitive volume of 0.004 mm(3), a nominal sensitivity of 1 nC Gy(-1) and operates at 0 V. Unlike natural diamond based detectors, the CVD diamond detector reports a low dose rate dependence. The dosimetric properties investigated in this work were dose rate, angular dependence and detector sensitivity and linearity. Also, percentage depth dose, off-axis dose profiles and total scatter ratios were measured and compared against equivalent measurements performed with a stereotactic diode. A Monte Carlo simulation was carried out to estimate the CVD small beam correction factors for a 6 MV photon beam. The small beam correction factors were compared with those obtained from stereotactic diode and ionization chambers in the same irradiation conditions The experimental measurements were performed in 6 and 15 MV photon beams with the following square field sizes: 10 × 10, 5 × 5, 4 × 4, 3 × 3, 2 × 2, 1.5 × 1.5, 1 × 1 and 0.5 × 0.5 cm. The CVD detector showed an excellent signal stability (<0.2%) and linearity, negligible dose rate dependence (<0.2%) and lower response angular dependence. The percentage depth dose and off-axis dose profiles measurements were comparable (within 1%) to the measurements performed with ionization chamber and diode in both conventional and small radiotherapy beams. For the 0.5 × 0.5 cm, the measurements performed with the CVD detector showed a partial volume effect for all the dosimetric quantities measured. The Monte Carlo simulation showed that the small beam correction factors were close to unity (within 1.0%) for field sizes ≥1 cm. The synthetic diamond detector had high linearity, low angular and negligible dose rate dependence, and its response was energy independent within 1% for field sizes from 1.0 to 5.0 cm. This work provides new data showing the performance of the CVD detector compared against a high spatial resolution diode. It also presents a comparison of the CVD small beam correction factors with those of diode and ionization chamber for a 6 MV photon beam.
Natural additives to preserve quality and improve nutritional value of fresh-cut nectarine.
Falagán, Natalia; Artés, Francisco; Aguayo, Encarna
2016-07-01
There is currently a high demand for natural and fresh-cut fruits. In this study, natural additives were applied to fresh-cut nectarines: (1) control, nontreated; (2) wedges were dipped in an antibrowning solution containing calcium ascorbate (AB); (3) and (4) wedges were dipped in an AB plus natural antimicrobial agents (vanillin or cinnamic acid, respectively). After these treatments, fresh-cut nectarines were packed and stored at 5 ℃ for eight days. The treatments AB+Vanillin and AB+Cinnamic inhibited microbial counts when compared with control and AB-only samples. The application of these solutions did not impart any aromas or off-flavors to nectarines and maintained firmness during the shelf-life period. AB solutions inhibited polyophenol oxidase action and reduced browning while stabilizing the soluble phenolic content, increasing consumer's acceptance. Nectarine wedges assimilated the ascorbic acid from the AB solution and retained it during the shelf-life period. The combination of an antibrowning agent and natural antimicrobials helped to control microbiological growth while maintaining high-quality parameters. They can be an attractive "green" alternative for organic fresh-cut products to other chemical sanitizers such as chlorine. © The Author(s) 2015.
Antony, Bhavna J; Stetson, Paul F; Abramoff, Michael D; Lee, Kyungmoo; Colijn, Johanna M; Buitendijk, Gabriëlle H S; Klaver, Caroline C W; Roorda, Austin; Lujan, Brandon J
2015-07-01
Off-axis acquisition of spectral domain optical coherence tomography (SDOCT) images has been shown to increase total retinal thickness (TRT) measurements. We analyzed the reproducibility of TRT measurements obtained using either the retinal pigment epithelium (RPE) or Bruch's membrane as reference surfaces in off-axis scans intentionally acquired through multiple pupil positions. Five volumetric SDOCT scans of the macula were obtained from one eye of 25 normal subjects. One scan was acquired through a central pupil position, while subsequent scans were acquired through four peripheral pupil positions. The internal limiting membrane, the RPE, and Bruch's membrane were segmented using automated approaches. These volumes were registered to each other and the TRT was evaluated in 9 Early Treatment of Diabetic Retinopathy Study (ETDRS) regions. The reproducibility of the TRT obtained using the RPE was computed using the mean difference, coefficient of variation (CV), and the intraclass correlation coefficient (ICC), and compared to those obtained using Bruch's membrane as the reference surface. A secondary set of 1545 SDOCT scans was also analyzed in order to gauge the incidence of off-axis scans in a typical acquisition environment. The photoreceptor tips were dimmer in off-axis images, which affected the RPE segmentation. The overall mean TRT difference and CV obtained using the RPE were 7.04 ± 4.31 μm and 1.46%, respectively, whereas Bruch's membrane was 1.16 ± 1.00 μm and 0.32%, respectively. The ICCs at the subfoveal TRT were 0.982 and 0.999, respectively. Forty-one percent of the scans in the secondary set showed large tilts (> 6%). RPE segmentation is confounded by its proximity to the interdigitation zone, a structure strongly affected by the optical Stiles-Crawford effect. Bruch's membrane, however, is unaffected leading to a more robust segmentation that is less dependent upon pupil position. The way in which OCT images are acquired can independently affect the accuracy of automated retinal thickness measurements. Assessment of scan angle in a clinical dataset demonstrates that off-axis scans are common, which emphasizes the need for caution when relying on automated thickness parameters when this component of scan acquisition is not controlled for.
PREVAIL: IBM's e-beam technology for next generation lithography
NASA Astrophysics Data System (ADS)
Pfeiffer, Hans C.
2000-07-01
PREVAIL - Projection Reduction Exposure with Variable Axis Immersion Lenses represents the high throughput e-beam projection approach to NGL which IBM is pursuing in cooperation with Nikon Corporation as alliance partner. This paper discusses the challenges and accomplishments of the PREVAIL project. The supreme challenge facing all e-beam lithography approaches has been and still is throughput. Since the throughput of e-beam projection systems is severely limited by the available optical field size, the key to success is the ability to overcome this limitation. The PREVAIL technique overcomes field-limiting off-axis aberrations through the use of variable axis lenses, which electronically shift the optical axis simultaneously with the deflected beam so that the beam effectively remains on axis. The resist images obtained with the Proof-of-Concept (POC) system demonstrate that PREVAIL effectively eliminates off- axis aberrations affecting both resolution and placement accuracy of pixels. As part of the POC system a high emittance gun has been developed to provide uniform illumination of the patterned subfield and to fill the large numerical aperture projection optics designed to significantly reduce beam blur caused by Coulomb interaction.
NASA Astrophysics Data System (ADS)
Pfeiffer, Hans
1999-12-01
Projection reduction exposure with variable axis immersion lenses (PREVAIL) represents the high throughput e-beam projection approach to next generation lithography (NGL), which IBM is pursuing in cooperation with Nikon Corporation as an alliance partner. This paper discusses the challenges and accomplishments of the PREVAIL project. The supreme challenge facing all e-beam lithography approaches has been and still is throughput. Since the throughput of e-beam projection systems is severely limited by the available optical field size, the key to success is the ability to overcome this limitation. The PREVAIL technique overcomes field-limiting off-axis aberrations through the use of variable axis lenses, which electronically shift the optical axis simultaneously with the deflected beam, so that the beam effectively remains on axis. The resist images obtained with the proof-of-concept (POC) system demonstrate that PREVAIL effectively eliminates off-axis aberrations affecting both the resolution and placement accuracy of pixels. As part of the POC system a high emittance gun has been developed to provide uniform illumination of the patterned subfield, and to fill the large numerical aperture projection optics designed to significantly reduce beam blur caused by Coulombinteraction.
Vijay, Kamath; Shetty, Ajoy Prasad
2009-01-01
The correction of severe post-tubercular kyphosis (PTK) is complex and has the disadvantage of being multiple staged with a high morbidity. Here, we describe the procedure and results of closing–opening osteotomy for correction of PTK which shortens the posterior column and opens the anterior column appropriately to correct the deformity without altering the length of the spinal cord. Seventeen patients with PTK (10 males; 7 females) with an average age of 18.3 ± 10.6 years (range 4–40 years) formed the study group. There were ten thoracolumbar, one lumbar and six thoracic deformities. The number of vertebrae involved ranged from 2 to 5 (average 2.8). Preoperative kyphosis averaged 69.2° ± 25.1° (range 42°–104°) which included ten patients with deformity greater than 60°. The average vertebral body loss was 2.01 ± 0.79 (range 1.1–4.1). The neurological status was normal in 13 patients, Frankel’s grade D in three patients and grade C in one. Posterior stabilization with pedicle screw instrumentation was followed by a preoperatively calculated wedge resection. Anterior column reconstruction was performed using rib grafts in four, tricortical iliac bone graft in five, cages in six, and bone chips alone and fibular graft in one patient each. Average operating time was 280 min (200–340 min) with an average blood loss of 820 ml (range 500–1,600 ml). The postoperative kyphosis averaged 32.4° ± 19.5° (range 8°–62°). The percentage correction of kyphosis achieved was 56.8 ± 14.6% (range 32–83%). No patient with normal preoperative neurological status showed deterioration in neurology after surgery. The last follow-up was at an average of 43 ± 4 months (range 32–64 months). The average loss of correction at the last follow-up was 5.4° (range 3°–9°). At the last follow-up, the mean preoperative pain visual analogue scale score decreased significantly from 9.2 (range 8–10 points) to 1.5 (range 1–2 points). There was also a significant decrease in mean preoperative Oswestry’s Disability Index from 56.4 (range 46–68) to 10.6 (range 6–15). Complications were superficial wound infections in two, neurological deterioration in one, temporary jaundice in one and implant failure requiring revision in one. Single-stage closing–opening wedge osteotomy is an effective method to correct severe PTK. The procedure has the advantage of being a posterior only, single-stage correction, which allows for significant correction with minimal complications. PMID:20013004
NASA Astrophysics Data System (ADS)
Shimizu, K.; Saal, A. E.; Hauri, E. H.; Nagle, A.; Forsyth, D. W.; Niu, Y.
2011-12-01
Off-axis seamounts and intra-transform lavas provide more direct geochemical information of the mantle than axial lavas. These smaller volumes of melts undergo lower extent of crystal fractionation and mixing compared to basalts erupting within the ridge axis due to a lack of long-lived magma chambers or along axis melt migration. Therefore, their study provide not only a more reliable approach to determine the volatile content of the intrinsic components forming the Earth's upper mantle, but also help constrain mantle convection, heterogeneity, and crustal recycling. Samples from the Quebrada-Discovery-Gofar (QDG) transform fault system (EPR 3°-5°S) and from northern EPR seamounts (5°-15° N) were collected during KN182-13 (R/V Knorr) and RAIT 02 (R/V Thomas Washington) expeditions, respectively. 159 submarine glasses were analyzed for major elements, trace elements, and volatile elements by triplicate analyses, as well as for Sr and Nd isotopes in a subset of samples. The QDG and northern EPR seamounts have similar trace element and isotopic composition that is consistent with melting of two-component mantle common to both regions. The degree of trace element enrichment (e.g. Th/La), isotopic composition, and depth of melt segregation (e.g. Sm/Yb) have a positive correlation and range from ultra depleted to relatively enriched compositions. In order to investigate the primary volatile content of submarine glasses we first considered shallow level processes, such as volatile degassing, sulfide saturation and interaction of melt with hydrothermally altered material. The vapor-melt equilibrium pressure (Dixon et al., 1995) indicates that the majority of the samples were super-saturated in CO2-H2O vapor at the pressure of eruption, which implies rapid magma ascent rate that prevented complete CO2 degassing. Samples that were sulfide saturated (Liu et al., 2007) and contaminated by seawater or seawater derived material (high Cl/K) were filtered out. F/Nd, Cl/K, and H2O/Ce ratios in our samples positively correlate with Th/La, Sm/Yb, and isotope ratios suggesting that the enriched mantle component is also enriched in volatile contents. S/Dy ratios are the exception, with relatively constant values in both enriched, and depleted basalts. Although it has been argued that correlation between Sr, Nd and Pb isotope ratios and fractionation corrected major element in seamount samples indicate different mantle lithologies under the mid-ocean ridges, we will show that such correlation might be an artifact of ignoring the effect of water during the correction for fractional crystallization. [1] Dixon et al. (1995) J. Pet., 36, 1607-1631. [2] Liu et al. (2007) Geochim Cosmochim Ac., 71, 1783-1799.
The relationship between black carbon concentration and black smoke: A more general approach
NASA Astrophysics Data System (ADS)
Heal, Mathew R.; Quincey, Paul
2012-07-01
The black carbon (BC) component of ambient particulate matter is an important marker for combustion sources and for its impact on human health and radiative forcing. Extensive data archives exist for the black smoke metric, the historic measure of ambient particle darkness. An expression presented in earlier publications (Quincey, 2007; Quincey et al., 2011) for estimating BC concentrations from traditional black smoke measurements is shown to have limitations that can be addressed by using a more systematic approach to the issue of corrections for increasing darkening of the filter. The form of the more general relationship is shown to be an off-axis parabola rather than the on-axis parabola of the earlier work. Existing data from co-located black smoke and aethalometer measurements at 5 UK sites are reanalysed in this context. At very low concentrations of dark particles (British Black Smoke index < ˜10 μg m-3) a simple linear relationship BC (/μg m-3) ≈ 0.27·BSIBRITISH will suffice. A parabolic relationship, [BC/μgm]=√{5.2-1.1+1.5×BSI+62-13+19}-7.9-0.9+1.1, quantitatively similar to the previously published relationship will be more reliable for BSIBRITISH values up to 20-25 μg m-3. The full set of data available was fitted empirically to the off-axis parabola over the range 0-80 μg m-3 as the quadratic: [BC/μg m-3] = (0.27 ± 0.03) · BSIBRITISH - (4.0 ± 0.2) × 10-4(BSIBRITISH)2, but this curve is highly dependent on the variations between the individual data sets. Adding the extra complexity of the full off-axis parabolic relationship is unlikely to be justified in practical situations. All expressions apply also to the OECD definition of black smoke with the substitution BSIBRITISH = 0.85·BSIOECD. However, in common with the previous approach, they apply only to black smoke values obtained from standard black smoke samplers with 25 mm diameter filters and ˜2 m3 day-1 volumetric flow rate, and presume a value 16.6 m2 g-1 for the specific absorption of BC in ambient particulate matter measured by aethalometry. Fitting uncertainties correspond to imprecision in estimated BC of ±5%, ±12% and ±18% at BSIBRITISH of 5, 20 and 80 μg m-3, respectively. Spatial and temporal variation in particle ensemble optical properties contributes to uncertainty in BC quantification.
Sediment Suspension by Straining-Induced Convection at the Head of Salinity Intrusion
NASA Astrophysics Data System (ADS)
Zhang, Qianjiang; Wu, Jiaxue
2018-01-01
The tidal straining can generate convective motions and exert a periodic modification of turbulence and sediment transport in estuarine and coastal bottom boundary layers. However, the evidence and physics of convection and sediment suspension induced by tidal straining have not been straightforward. To examine these questions, mooring and transect surveys have been conducted in September 2015 in the region of the Yangtze River plume influence. Field observations and scaling analyses indicate an occurrence of convective motions at the head of saline wedge. Theoretical analyses of stratification evolution in the saline wedge show that unstable stratification and resultant convection are induced by tidal straining. Vertical turbulent velocity and eddy viscosity at the head of saline wedge are both larger than their neutral counterparts in the main body, largely enhancing sediment suspension at the head of saline wedge. Moreover, sediment suspension in both neutral and convection-affected flows is supported by the variance of vertical turbulent velocity, rather than the shearing stress. Finally, the stability correction functions in the Monin-Obukhov similarity theory can be simply derived from the local turbulent kinetic energy balance to successfully describe the effects of tidal straining on turbulent length scale, eddy viscosity, and sediment diffusivity in the convection-affected flow. These recognitions may provide novel understanding of estuarine turbidity maxima, and the dynamical structure and processes for coastal hypoxia.
Zhang, Shuzeng; Li, Xiongbing; Jeong, Hyunjo; Hu, Hongwei
2018-05-12
Angle beam wedge transducers are widely used in nonlinear Rayleigh wave experiments as they can generate Rayleigh wave easily and produce high intensity nonlinear waves for detection. When such a transducer is used, the spurious harmonics (source nonlinearity) and wave diffraction may occur and will affect the measurement results, so it is essential to fully understand its acoustic nature. This paper experimentally investigates the nonlinear Rayleigh wave beam fields generated and received by angle beam wedge transducers, in which the theoretical predictions are based on the acoustic model developed previously for angle beam wedge transducers [S. Zhang, et al., Wave Motion, 67, 141-159, (2016)]. The source of the spurious harmonics is fully characterized by scrutinizing the nonlinear Rayleigh wave behavior in various materials with different driving voltages. Furthermore, it is shown that the attenuation coefficients for both fundamental and second harmonic Rayleigh waves can be extracted by comparing the measurements with the predictions when the experiments are conducted at many locations along the propagation path. A technique is developed to evaluate the material nonlinearity by making appropriate corrections for source nonlinearity, diffraction and attenuation. The nonlinear parameters of three aluminum alloy specimens - Al 2024, Al 6061 and Al 7075 - are measured, and the results indicate that the measurement results can be significantly improved using the proposed method. Copyright © 2018. Published by Elsevier B.V.
Accelerated characterization of graphite/epoxy composites
NASA Technical Reports Server (NTRS)
Griffith, W. I.; Morris, D. H.; Brinson, H. F.
1980-01-01
A method to predict the long term compliance of unidirectional off-axis laminates from short term laboratory tests is presented. The method uses an orthotropic transformation equation and the time-stress-temperature superposition principle. Short term tests are used to construct master curves for two off-axis unidirectional laminates with fiber angles of 10 and 90 degrees. Analytical predictions of long term compliance for 30 and 60 degrees laminates are made. Comparisons with experimental data are also given.
Optical cylinder designs to increase the field of vision in the osteo-odonto-keratoprosthesis.
Hull, C C; Liu, C S; Sciscio, A; Eleftheriadis, H; Herold, J
2000-12-01
The single optical cylinders used in the osteo-odonto-keratoprosthesis (OOKP) are known to produce very small visual fields. Values of 40 degrees are typically quoted. The purpose of this paper is to present designs for new optical cylinders that significantly increase the field of view and therefore improve the visual rehabilitation of patients having an OOKP. Computer ray-tracing techniques were used to design and analyse improved one- and two-piece optical cylinders made from polymethyl methacrylate. All designs were required to have a potential visual acuity of 6/6 before consideration was given to the visual field and optimising off-axis image quality. Aspheric surfaces were used where this significantly improved off-axis image quality. Single optical cylinders, with increased posterior cylinder (intraocular) diameters, gave an increase in the theoretical visual field of 18% (from 76 degrees to 90 degrees) over current designs. Two-piece designs based on an inverted telephoto principle gave theoretical field angles over 120 degrees. Aspheric surfaces were shown to improve the off-axis image quality while maintaining a potential visual acuity of at least 6/6. This may well increase the measured visual field by improving the retinal illuminance off-axis. Results demonstrate that it is possible to significantly increase the theoretical maximum visual field through OOKP optical cylinders. Such designs will improve the visual rehabilitation of patients undergoing this procedure.
A Study of Electron Modes in Off-axis Heated Alcator C-Mod Plasmas
NASA Astrophysics Data System (ADS)
Fiore, C. L.; Ernst, D. R.; Mikkelsen, D.; Ennever, P. C.; Howard, N. T.; Gao, C.; Reinke, M. L.; Rice, J. E.; Hughes, J. W.; Walk, J. R.
2013-10-01
Understanding the underlying physics and stability of the peaked density internal transport barriers (ITB) that have been observed during off-axis ICRF heating of Alcator C-Mod plasmas is the goal of recent gyro-kinetic simulations. Two scenarios are examined: an ITB plasma formed with maximal (4.5 MW) off-axis heating power; also the use of off-axis heating in an I-mode plasma as a target in the hopes of establishing an ITB. In the former, it is expected that evidence of trapped electron mode instabilities could be found if a sufficiently high electron temperature is achieved in the core. Linear simulations show unstable modes are present across the plasma core from r/a = 0.2 and greater. In the latter case, despite establishing similar conditions to those in which ITBS were formed, none developed in the I-mode plasmas. Linear gyrokinetic analyses show no unstable ion modes at r/a < 0.55 in these I-mode plasmas, with both ITG and ETG modes present beyond r/a = 0.65. The details of the experimental results will be presented. Linear and non-linear simulations of both of these cases will attempt to explore the underlying role of electron and ion gradient driven instabilities to explain the observations. This work was supported by US-DoE DE-FC02-99ER54512 and DE-AC02-09CH11466.
Destabilization of counter-propagating TAEs by off-axis, co-current Neutral Beam Injection
NASA Astrophysics Data System (ADS)
Podesta', M.; Fredrickson, E.; Gorelenkova, M.
2017-10-01
Neutral Beam injection (NBI) is a common tool to heat the plasma and drive current non-inductively in fusion devices. Energetic particles (EP) resulting from NBI can drive instabilities that are detrimental for the performance and the predictability of plasma discharges. A broad NBI deposition profile, e.g. by off-axis injection aiming near the plasma mid-radius, is often assumed to limit those undesired effects by reducing the radial gradient of the EP density, thus reducing the ``universal'' drive for instabilities. However, this work presents new evidence that off-axis NBI can also lead to undesired effects such as the destabilization of Alfvénic instabilities, as observed in NSTX-U plasmas. Experimental observations indicate that counter propagating toroidal AEs are destabilized as the radial EP density profile becomes hollow as a result of off-axis NBI. Time-dependent analysis with the TRANSP code, augmented by a reduced fast ion transport model (known as kick model), indicates that instabilities are driven by a combination of radial and energy gradients in the EP distribution. Understanding the mechanisms for wave-particle interaction, revealed by the phase space resolved analysis, is the basis to identify strategies to mitigate or suppress the observed instabilities. Work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences under Contract Number DE-AC02-09CH11466.
NASA Astrophysics Data System (ADS)
White, S. M.; Lee, A. J.; Rubin, K. H.
2015-12-01
Two Alvin dives (AL 4771 and 4774) transected the seafloor directly above the two largest Off-Axis Melt Lenses (O-AML) east of the East Pacific Rise (EPR) axis at 9 39'N and 9 54'N. In 2008, a 3D high-resolution seismic reflection survey (MGL-0812) discovered O-AMLs 3-7 km from the EPR at 2-3 km below the seafloor. Several other O-AML in the crust have been subsequently detected in several locations up to 20 km from the spreading axis at fast and intermediate spreading ridges; understanding their impacts is increasingly important. During the dives, no currently active hydrothermal venting or fresh lava was seen, suggesting that these features do not constantly power off-axis geological activity. However, the seafloor appears much younger at small volcanic seamounts in the 9 39'N than at the 9 54'N site. At 9 39'N, we used Alvin to explore the off-axis volcanic mound complex, reaching the summit of the three largest mounds. Although no evidence for on-going hydrothermal or volcanic activity was detected, the seafloor wore a thin sediment layer of ~10cm and thin Mn-coatings on 9 rock samples, suggesting volcanism more recently than would be expected based on the spreading-rate age of the crust. At 9 54'N, the Alvin trackline started south of a prominent abyssal hill, which has an unusual D-shape over 1 km wide in the center, crossed the abyssal hill, visited two local hummocks on top, and then attempted to find volcanic activity on the near slope of EPR axis by going as far west was possible during the dive. Heavy sediment everywhere on the abyssal hill, to the depth of push cores (~30 cm) and probably much deeper in many areas and 4 rock samples from the abyssal hill were quite weathered with little glass intact, suggest that this site is unaffected by the underlying O-AML. Upslope toward the EPR west of the abyssal hill, 4 rocks collected appear somewhat younger, and sediment became thinner. In addition, 3 CTD tow-yos over each O-AML found no evidence of active hydrothermal vents at either site. While these results do not support the idea of on-going and widespread volcanic activity associated with O-AMLs, a comprehensive survey may reveal smaller pockets of activity. A viable alternative is that off-axis activity is sparse and sporadic, perhaps focused by faults that tap into O-AML heat, and that O-AMLs warrant further investigation.
NASA Astrophysics Data System (ADS)
West, A. J.; Torres, M. A.; Nealson, K. H.
2014-12-01
Two Alvin dives (AL 4771 and 4774) transected the seafloor directly above the two largest Off-Axis Melt Lenses (O-AML) east of the East Pacific Rise (EPR) axis at 9 39'N and 9 54'N. In 2008, a 3D high-resolution seismic reflection survey (MGL-0812) discovered O-AMLs 3-7 km from the EPR at 2-3 km below the seafloor. Several other O-AML in the crust have been subsequently detected in several locations up to 20 km from the spreading axis at fast and intermediate spreading ridges; understanding their impacts is increasingly important. During the dives, no currently active hydrothermal venting or fresh lava was seen, suggesting that these features do not constantly power off-axis geological activity. However, the seafloor appears much younger at small volcanic seamounts in the 9 39'N than at the 9 54'N site. At 9 39'N, we used Alvin to explore the off-axis volcanic mound complex, reaching the summit of the three largest mounds. Although no evidence for on-going hydrothermal or volcanic activity was detected, the seafloor wore a thin sediment layer of ~10cm and thin Mn-coatings on 9 rock samples, suggesting volcanism more recently than would be expected based on the spreading-rate age of the crust. At 9 54'N, the Alvin trackline started south of a prominent abyssal hill, which has an unusual D-shape over 1 km wide in the center, crossed the abyssal hill, visited two local hummocks on top, and then attempted to find volcanic activity on the near slope of EPR axis by going as far west was possible during the dive. Heavy sediment everywhere on the abyssal hill, to the depth of push cores (~30 cm) and probably much deeper in many areas and 4 rock samples from the abyssal hill were quite weathered with little glass intact, suggest that this site is unaffected by the underlying O-AML. Upslope toward the EPR west of the abyssal hill, 4 rocks collected appear somewhat younger, and sediment became thinner. In addition, 3 CTD tow-yos over each O-AML found no evidence of active hydrothermal vents at either site. While these results do not support the idea of on-going and widespread volcanic activity associated with O-AMLs, a comprehensive survey may reveal smaller pockets of activity. A viable alternative is that off-axis activity is sparse and sporadic, perhaps focused by faults that tap into O-AML heat, and that O-AMLs warrant further investigation.
Astigmatism-free Czerny-Turner compact spectrometer with cylindrical mirrors.
Xia, Guo; Wu, Su; Wang, Guodong; Hu, Mingyong; Xing, Jinyu
2017-11-10
A modified optical design for a broadband, high resolution, astigmatism-free Czerny-Turner spectrometer is proposed. Astigmatism is corrected by using cylindrical mirrors over a broad spectral range. The theory and method for astigmatism correction are thoroughly analyzed. The comparison between the modified Czerny-Turner spectrometer and the traditional Czerny-Turner spectrometer is also described in detail. The ray-tracing results show that the RMS spot radius has decreased to 4.2 μm at the central wavelength and 17 μm at the wedge wavelength.
GALACSI system design and analysis
NASA Astrophysics Data System (ADS)
Ströbele, S.; La Penna, P.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Duchateau, M.; Dorn, R.; Fedrigo, E.; Hubin, N.; Quentin, J.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J. L.; Madec, P.-Y.; Pettazzi, L.; Soenke, C.; Tordo, S.; Vernet, J.; Muradore, R.
2012-07-01
GALACSI is one of the Adaptive Optics (AO) systems part of the ESO Adaptive Optics Facility (AOF). It will use the VLT 4-Laser Guide Stars system, high speed and low noise WaveFront Sensor cameras (<1e-, 1000Hz) the Deformable Secondary Mirror (DSM) and the SPARTA Real Time Computer to sharpen images and enhance faint object detectability of the MUSE Instrument. MUSE is an Integral Field Spectrograph working at wavelengths from 465nm to 930nm. GALACSI implements 2 different AO modes; in Wide Field Mode (WFM) it will perform Ground Layer AO correction and enhance the collected energy in a 0.2" by 0.2" pixel by a factor 2 at 750nm over a Field of View (FoV) of 1' by 1'. The 4 LGSs and one tip tilt reference star (R-mag <17.5) are located outside the MUSE FoV. Key requirements are to provide this performance and a very good image stability for a 1hour long integration time. In Narrow Field Mode (NFM) Laser Tomography AO will be used to reconstruct and correct the turbulence for the center field using the 4 LGSs at 15" off axis and the Near Infra Red (NIR) light of one reference star on axis for tip tilt and focus sensing. In NFM GALACSI will provide a moderate Strehl Ratio of 5% (goal 10%) at 650nm. The NFM hosts several challenges and many subsystems will be pushed to their limits. The opto mechanical design and error budgets of GALACSI is described here.
NASA Technical Reports Server (NTRS)
Wells, Mark
2017-01-01
Active positioning of the GHAPS secondary telescope mirror is desired to correct for rigid body deflections due to temperature variations and gravity sag in the telescope structure that may impact optical performance. The current design concept for the secondary mirror mount uses a Commercial-Off -the-Shelf hexapod for mirror positioning and fine adjustment. The Hexapod specification states that motions as small as 0.1 microns along the optical axis and 2 microns perpendicular to the optical axis will cause optical aberrations that will require correction by repositioning the secondary mirror. In addition, the secondary mirror mount and positioning system must survive a 15g shock of parachute opening and landing during the instrument recovery operation. The secondary mirror positioning system must operate at a minimum specified temperature of -50 C. The telescope operates in the IR and the secondary mirror mount and positioning device is in the metering path between the primary and secondary mirrors. I2R losses in positioning system actuator devices, which may cause heating of the positioning system and secondary mirror, must be minimized due to the previously mentioned alignment sensitivity and the viewing spectrum of interest. The GHAPs project was cancelled on June 30, 2017. The purpose of this study is to address some of the issues identified with the hexapod secondary mirror positioning system and identify alternative approaches. This information may be used if the project is re-started at a later date.
NASA Astrophysics Data System (ADS)
Vieira, Ivo; Lobo, Francisco José; Montoya-Montes, Isabel; Siegle, Eduardo; Passos, Jorge Luiz; De Mahiques, Michel Michaelovitch
2018-02-01
São Sebastião Island (SSI) marks the latitudinal boundary between two sedimentological and geochemical provinces in the São Paulo Bight, an arc-shaped sector of the southeastern Brazilian Shelf. The island is separated from the continent by the narrow, deep São Sebastião Channel (SSC). A relatively thick sediment wedge—the São Sebastião Wedge (SSW)—has been formed offshore SSI. This study explores the possible genetic and evolutionary mechanisms of the wedge, bearing in mind that clinoform wedges can form at considerable distances from major fluvial sources. For that, a marine geological database has been interpreted comprising high-resolution seismic data, a surficial sediment map and several sediment cores, from which radiocarbon dates were obtained and sedimentation rates deduced. A wave model was also applied to obtain the dominant wave directions. The SSW is a wedge-shaped deposit, and its internal structure presents three seismic units. The two lowest are wedge shaped and arranged in a backstepping pattern. The most recent unit is mostly aggradational and can be divided into three seismic subunits. Sedimentological data show that at least the most recent unit is composed of a mixture of sands and silts. Modeled wave conditions indicate a major influence from southerly waves that are able to remobilize shelf sediments and to create a bypass sediment zone until the foreset of the deposit is reached at the water depths where the SSW is found. Taken together, these data suggest that the SSW formed through contributions from different sediment sources, and should be regarded as an intermediate case of a non-deltaic clinoform wedge. Sand transport in the area involves wind-driven currents passing through the SSC and sediment remobilization by energetic southerly waves. Fine-grained sediment is derived mostly from the joint contributions of many minor catchments located north of the island, and this sediment is later transported southwestward by the prevailing surface currents. The morphological obstacle presented by the island leads to current veering and subsequent sediment deposition. The internal architecture of the wedge indicates that its deposition was probably initiated during the last part of the postglacial transgression, but its present-day morphology is mostly a product of episodic highstand sedimentation that began under conditions of gently falling sea levels during the last 5 ka, after the Holocene glacio-eustatic maximum.
Jeyaseelan, L; Chandrashekar, S; Mulligan, A; Bosman, H A; Watson, A J S
2016-09-01
The mainstay of surgical correction of hallux valgus is first metatarsal osteotomy, either proximally or distally. We present a technique of combining a distal chevron osteotomy with a proximal opening wedge osteotomy, for the correction of moderate to severe hallux valgus. We reviewed 45 patients (49 feet) who had undergone double osteotomy. Outcome was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) and the Short Form (SF) -36 Health Survey scores. Radiological measurements were undertaken to assess the correction. The mean age of the patients was 60.8 years (44.2 to 75.3). The mean follow-up was 35.4 months (24 to 51). The mean AOFAS score improved from 54.7 to 92.3 (p < 0.001) and the mean SF-36 score from 59 to 86 (p < 0.001). The mean hallux valgus and intermetatarsal angles were improved from 41.6(o) to 12.8(o) (p < 0.001) and from 22.1(o) to 7.1(o), respectively (p < 0.001). The mean distal metatarsal articular angle improved from 23(o) to 9.7(o). The mean sesamoid position, as described by Hardy and Clapham, improved from 6.8 to 3.5. The mean length of the first metatarsal was unchanged. The overall rate of complications was 4.1% (two patients). These results suggest that a double osteotomy of the first metatarsal is a reliable, safe technique which, when compared with other metatarsal osteotomies, provides strong angular correction and excellent outcomes with a low rate of complications. Cite this article: Bone Joint J 2016;98-B:1202-7. ©2016 The British Editorial Society of Bone & Joint Surgery.
Cloverleaf microgyroscope with electrostatic alignment and tuning
NASA Technical Reports Server (NTRS)
Challoner, A. Dorian (Inventor); Gutierrez, Roman C. (Inventor); Tang, Tony K. (Inventor)
2007-01-01
A micro-gyroscope (10) having closed loop output operation by a control voltage (V.sub.ty), that is demodulated by a drive axis (x-axis) signal V.sub.thx of the sense electrodes (S1, S2), providing Coriolis torque rebalance to prevent displacement of the micro-gyroscope (10) on the output axis (y-axis) V.sub.thy.about.0. Closed loop drive axis torque, V.sub.tx maintains a constant drive axis amplitude signal, V.sub.thx. The present invention provides independent alignment and tuning of the micro-gyroscope by using separate electrodes and electrostatic bias voltages to adjust alignment and tuning. A quadrature amplitude signal, or cross-axis transfer function peak amplitude is used to detect misalignment that is corrected to zero by an electrostatic bias voltage adjustment. The cross-axis transfer function is either V.sub.thy/V.sub.ty or V.sub.tnx/V.sub.tx. A quadrature signal noise level, or difference in natural frequencies estimated from measurements of the transfer functions is used to detect residual mistuning, that is corrected to zero by a second electrostatic bias voltage adjustment.
NASA Astrophysics Data System (ADS)
Wang, Yang; Wang, Qianqian
2008-12-01
When laser ranger is transported or used in field operations, the transmitting axis, receiving axis and aiming axis may be not parallel. The nonparallelism of the three-light-axis will affect the range-measuring ability or make laser ranger not be operated exactly. So testing and adjusting the three-light-axis parallelity in the production and maintenance of laser ranger is important to ensure using laser ranger reliably. The paper proposes a new measurement method using digital image processing based on the comparison of some common measurement methods for the three-light-axis parallelity. It uses large aperture off-axis paraboloid reflector to get the images of laser spot and white light cross line, and then process the images on LabVIEW platform. The center of white light cross line can be achieved by the matching arithmetic in LABVIEW DLL. And the center of laser spot can be achieved by gradation transformation, binarization and area filter in turn. The software system can set CCD, detect the off-axis paraboloid reflector, measure the parallelity of transmitting axis and aiming axis and control the attenuation device. The hardware system selects SAA7111A, a programmable vedio decoding chip, to perform A/D conversion. FIFO (first-in first-out) is selected as buffer.USB bus is used to transmit data to PC. The three-light-axis parallelity can be achieved according to the position bias between them. The device based on this method has been already used. The application proves this method has high precision, speediness and automatization.
NASA Technical Reports Server (NTRS)
Degnan, John J. (Inventor)
2007-01-01
This invention is directed to a 3-dimensional imaging lidar, which utilizes modest power kHz rate lasers, array detectors, photon-counting multi-channel timing receivers, and dual wedge optical scanners with transmitter point-ahead correction to provide contiguous high spatial resolution mapping of surface features including ground, water, man-made objects, vegetation and submerged surfaces from an aircraft or a spacecraft.
NASA Astrophysics Data System (ADS)
Carlson, C. W.; Pluhar, C. J.; Glen, J. M.; Farner, M. J.
2012-12-01
Accommodating ~20-25% of the dextral-motion between the Pacific and North American plates the Walker Lane is represented as an elongate, NW oriented, region of active tectonics positioned between the northwesterly-translating Sierra Nevada microplate and the east-west extension of the Basin and Range. This region of transtension is being variably accommodated on regional-scale systems of predominantly strike-slip faulting. At the western edge of the central Walker Lane (ca. 38°-39°N latitude) is a region of crustal-scale blocks bounded by wedge-shaped depositional-basins and normal-fault systems, here defined as the west-central Walker Lane (WCWL). Devoid of obvious strike-slip faulting, the presence of tectonic-block vertical-axis rotations in the WCWL represents unrecognized components of dextral-shearing and/or changes of strain-accommodation over time. We use paleomagnetic reference directions for Eureka Valley Tuff (EVT) members of the late Miocene Stanislaus Group as spatial and temporal markers for documentation of tectonic-block vertical-axis rotations near Bridgeport, CA. Study-site rotations revealed discrete rotational domains of mean vertical-axis rotation ranging from ~10°-30° with heterogeneous regional distribution. Additionally, the highest measured magnitudes of vertical-axis rotation (~50°-60° CW) define a 'Region of High Strain' that includes the wedge-shaped Bridgeport Valley (Basin). This study revealed previously-unrecognized tectonic rotation of reference direction sites from prior studies for two (By-Day and Upper) of the three members of the EVT, resulting in under-estimates of regional strain accommodation by these studies. Mean remanent directions and virtual geomagnetic poles utilized in our study yielded a recalculated reference direction for the By-Day member of: Dec.=353.2°; Inc.= 43.7°; α95=10.1, in agreement with new measurements in the stable Sierra Nevada. This recalculated direction confirmed the presence of previously unrecognized reference site rotations, and provided an additional reference direction for determining vertical-axis rotation magnitudes. We present a kinematic model based on mean rotation magnitudes of ~30° CW for the Sweetwater Mountains and Bodie Hills that accounts for rotational-strain accommodation of dextral shear in the WCWL since the late Miocene. This model considers rotational magnitudes, paleostrain indicators, edge-effects, and strain-accommodating structures of rotating crustal blocks to represent changes in regional strain accommodation over time. The results and models presented here elucidate the complicated and evolving nature of the WCWL, and further understanding of variations in strain accommodation for the Walker Lane.
NASA Astrophysics Data System (ADS)
Hasenclever, Jörg; Rüpke, Lars; Theissen-Krah, Sonja; Morgan, Jason
2016-04-01
We use 3-D numerical models of hydrothermal fluid flow to assess the magnitude and spatial distribution of hydrothermal mass and energy fluxes within the upper and lower oceanic crust. A better understanding of the hydrothermal flow pattern (e.g. predominantly on-axis above the axial melt lens vs. predominantly off-axis and ridge-perpendicular over the entire crustal thickness) is essential for quantifying the volume of oceanic crust exposed to high-temperature fluid flow and the associated leaching and redistribution of economically interesting metals. The initial setup of all 3-D models is based on our previous 2-D studies (Theissen-Krah et al., 2011), in which we have coupled numerical models for crustal accretion and hydrothermal fluid flow. One result of these 2-D calculations is a crustal permeability field that leads to a thermal structure in the crust that matches seismic tomography data at the East Pacific Rise. Our reference 3-D model for hydrothermal flow at fast-spreading ridges predicts the existence of a hybrid hydrothermal system (Hasenclever et al., 2014) with two interacting flow components that are controlled by different physical mechanisms. Shallow on-axis flow structures develop owing to the thermodynamic properties of water, whereas deeper off-axis flow is strongly shaped by crustal permeability, particularly the brittle-ductile transition. About ˜60% of the discharging fluid mass is replenished on-axis by warm (up to 300oC) recharge flow surrounding the hot thermal plumes. The remaining ˜40%, however, occurs as colder and broader recharge up to several kilometres away from the ridge axis that feeds hot (500-700oC) deep off-axis flow in the lower crust towards the ridge. Both flow components merge above the melt lens to feed ridge-centred vent sites. In a suite of 3-D model calculations we vary the isotropic crustal permeability to quantify its influence on on-axis vs. off-axis hydrothermal fluxes as well as on along-axis hydrothermal activity. We also explore the effect of anisotropic permeability that is likely to be a feature of the diking region above the melt lens where the repeated emplacement of meter-size dikes should lead to higher permeability in vertical and along-ridge direction and to lower permeability across the ridge. We further study the effect of along-ridge depth-variations of the axial melt lens on the distribution of hydrothermal vent sites.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary
Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared headmore » position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.« less
Influence of temperature on the optical system with large diameter off-axis parabolic lenses
NASA Astrophysics Data System (ADS)
Su, Yaru; Ruan, Hao; Liu, Jie
2016-10-01
In this work, an optical system with large diameter off-axis parabolic lenses was adopted to achieve diffraction gratings by laser interference exposure. The diffraction wavefront aberration caused by temperature variations was simulated using ZEMAX. Through theoretical analysis and optical simulation, it is proved that the diffraction wavefront aberration of holographic grating caused by the pinhole's location errors (it is assumed that when the displacement of pinhole exists along one axis, the locations of the pinhole along the other two orthogonal axes are in a state of precise adjustment ) is much larger when the displacement occurs along z axis than along the other two axes, and the diffraction wavefront aberration is the smallest when the displacement occurs along x axis. If the ambient temperature changes by 1 degree, the PV value is 0.0631λ when the location of the pinhole changes by 0.121mm along z axis, 0.0034λor 0.0672λ when the location of the pinhole changes by 0.002mm along x axis or 0.03mm along y axis. To reach the diffraction limit (that means the PV value is 0.25λ), the decentering value of the pinhole along z axis should be less than 0.0341mm. In conclusion, the position error along z axis is an important factor to influence the PV value of diffraction grating, and the effect of temperature on the PV value of diffraction grating can be neglected.
NASA Technical Reports Server (NTRS)
Dickman, J. D.; Angelaki, D. E.
1999-01-01
During linear accelerations, compensatory reflexes should continually occur in order to maintain objects of visual interest as stable images on the retina. In the present study, the three-dimensional organization of the vestibulo-ocular reflex in pigeons was quantitatively examined during linear accelerations produced by constant velocity off-vertical axis yaw rotations and translational motion in darkness. With off-vertical axis rotations, sinusoidally modulated eye-position and velocity responses were observed in all three components, with the vertical and torsional eye movements predominating the response. Peak torsional and vertical eye positions occurred when the head was oriented with the lateral visual axis of the right eye directed orthogonal to or aligned with the gravity vector, respectively. No steady-state horizontal nystagmus was obtained with any of the rotational velocities (8-58 degrees /s) tested. During translational motion, delivered along or perpendicular to the lateral visual axis, vertical and torsional eye movements were elicited. No significant horizontal eye movements were observed during lateral translation at frequencies up to 3 Hz. These responses suggest that, in pigeons, all linear accelerations generate eye movements that are compensatory to the direction of actual or perceived tilt of the head relative to gravity. In contrast, no translational horizontal eye movements, which are known to be compensatory to lateral translational motion in primates, were observed under the present experimental conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taira, Yoshitaka; Zhang, Shukui
Here, diffraction patterns of an optical vortex through several shaped apertures reveal its topological charge. In this letter, we theoretically and experimentally show that diffraction of a Laguerre Gaussian beam through a circular aperture at an off-axis position can be used to determine the magnitude and sign of the topological charge. To our knowledge, this is the first time that a simple circular aperture has been used to detect orbital angular momentum of an incident optical vortex.
Taira, Yoshitaka; Zhang, Shukui
2017-04-01
Diffraction patterns of an optical vortex through several shaped apertures reveal its topological charge. In this Letter, we theoretically and experimentally show that diffraction of a Laguerre Gaussian beam through a circular aperture at an off-axis position can be used to determine the magnitude and sign of the topological charge. To our knowledge, this is the first time that a simple circular aperture has been used to detect orbital angular momentum of an incident optical vortex.
Rodríguez, Guillermo López; Weber, Joshua; Sandhu, Jaswinder Singh; Anastasio, Mark A.
2011-01-01
We propose and experimentally demonstrate a new method for complex-valued wavefield retrieval in off-axis acoustic holography. The method involves use of an intensity-sensitive acousto-optic (AO) sensor, optimized for use at 3.3 MHz, to record the acoustic hologram and a computational method for reconstruction of the object wavefield. The proposed method may circumvent limitations of conventional implementations of acoustic holography and may facilitate the development of acoustic-holography-based biomedical imaging methods. PMID:21669451
Transverse Cracking in a Fiber Reinforced Ceramic Matrix Composite
1990-12-01
failure if the off-axis ply was very thin. Wang and Parvizi- Majidi (3) investigated transverse cracking in Nicalon/CAS, a ceramic composite with silicon...the off-axis ply was very thin. 7 Wang and Parvizi- Majidi (3) investigated transverse I cracking in Nicalon/CAS, a ceramic composite with silicon...were quite 3 prevalent in the three lay-ups with the 900 plies in the center, less so in the 0/90/04/90/0 lay-up. Wang and Parvizi- Majidi also
Taira, Yoshitaka; Zhang, Shukui
2017-03-29
Here, diffraction patterns of an optical vortex through several shaped apertures reveal its topological charge. In this letter, we theoretically and experimentally show that diffraction of a Laguerre Gaussian beam through a circular aperture at an off-axis position can be used to determine the magnitude and sign of the topological charge. To our knowledge, this is the first time that a simple circular aperture has been used to detect orbital angular momentum of an incident optical vortex.
Accelerated characterization of graphite/epoxy composites
NASA Technical Reports Server (NTRS)
Griffith, W. I.; Morris, D. H.; Brinson, H. F.
1980-01-01
A method to predict the long-term compliance of unidirectional off-axis laminates from short-term laboratory tests is presented. The method uses an orthotropic transformation equation and the time-stress-temperature superposition principle. Short-term tests are used to construct master curves for two off-axis unidirectional laminates with fiber angles of 10 deg and 90 deg. In addition, analytical predictions of long-term compliance for 30 deg and 60 deg laminates are made. Comparisons with experimental data are also given.
Nygate, Yoav N; Singh, Gyanendra; Barnea, Itay; Shaked, Natan T
2018-06-01
We present a new technique for obtaining simultaneous multimodal quantitative phase and fluorescence microscopy of biological cells, providing both quantitative phase imaging and molecular specificity using a single camera. Our system is based on an interferometric multiplexing module, externally positioned at the exit of an optical microscope. In contrast to previous approaches, the presented technique allows conventional fluorescence imaging, rather than interferometric off-axis fluorescence imaging. We demonstrate the presented technique for imaging fluorescent beads and live biological cells.
Structural design of off-axis aspheric surface reflective zoom optical system
NASA Astrophysics Data System (ADS)
Zhang, Ke; Chang, Jun; Song, Haiping; Niu, Yajun
2018-01-01
Designed an off-axis aspheric reflective zoom optical system, and produced a prototype. The system consists of three aspheric reflective lens, the zoom range is 30mm { 90mm. This system gave up the traditional structure of zoom cam, the lens moved using linear guide rail driven by motor, the positioning precision of which was 0.01mm. And introduced the design of support frames of each lens. The practice tests verified the rationality of the prototype structure design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strauss, H.R.
This paper describes the code FEMHD, an adaptive finite element MHD code, which is applied in a number of different manners to model MHD behavior and edge plasma phenomena on a diverted tokamak. The code uses an unstructured triangular mesh in 2D and wedge shaped mesh elements in 3D. The code has been adapted to look at neutral and charged particle dynamics in the plasma scrape off region, and into a full MHD-particle code.
Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization
NASA Technical Reports Server (NTRS)
Greem. David; DuToit, Cornelis
2013-01-01
The goal of this work was to improve off-axis cross-polarization performance and ease of assembly of a circularly polarized microwave antenna element. To ease assembly, the initial design requirement of Hexweb support for the internal circuit part, as well as the radiating disks, was eliminated. There is a need for different plating techniques to improve soldering. It was also desirable to change the design to eliminate soldering as well as the need to use the Hexweb support. Thus, a technique was developed to build the feed without using solder, solving the lathing and soldering issue. Internal parts were strengthened by adding curvature to eliminate Hexweb support, and in the process, the new geometries of the internal parts opened the way for improving the off-axis cross-polarization performance as well. The radiating disks curvatures were increased for increased strength, but it was found that this also improved crosspolarization. Optimization of the curvatures leads to very low off-axis cross-polarization. The feed circuit was curved into a cylinder for improved strength, eliminating Hexweb support. An aperture coupling feed mechanism eliminated the need for feed pins to the disks, which would have required soldering. The aperture coupling technique also improves cross-polarization performance by effectively exciting the radiating disks very close to the antenna s central axis of symmetry. Because of the shape of the parts, it allowed for an all-aluminum design bolted together and assembled with no solder needed. The advantage of a solderless design is that the reliability is higher, with no single-point failure (solder), and no need for special plating techniques in order to solder the unit together. The shapes (curved or round) make for a more robust build without extra support materials, as well as improved offaxis cross-polarization.
Lee, Chanseok; Lee, Jae Young; Kim, Do-Nyun
2018-02-07
The originally published version of this Article contained an error in Figure 5. In panel f, the right y-axis 'Strain energy (kbT)' was labelled 'Probability' and the left y-axis 'Probability' was labelled 'Strain energy (kbT)'. This error has now been corrected in both the PDF and HTML versions of the Article.
NASA Astrophysics Data System (ADS)
Shaked, Natan T.; Girshovitz, Pinhas; Frenklach, Irena
2014-06-01
We present our recent advances in the development of compact, highly portable and inexpensive wide-field interferometric modules. By a smart design of the interferometric system, including the usage of low-coherence illumination sources and common-path off-axis geometry of the interferometers, spatial and temporal noise levels of the resulting quantitative thickness profile can be sub-nanometric, while processing the phase profile in real time. In addition, due to novel experimentally-implemented multiplexing methods, we can capture low-coherence off-axis interferograms with significantly extended field of view and in faster acquisition rates. Using these techniques, we quantitatively imaged rapid dynamics of live biological cells including sperm cells and unicellular microorganisms. Then, we demonstrated dynamic profiling during lithography processes of microscopic elements, with thicknesses that may vary from several nanometers to hundreds of microns. Finally, we present new algorithms for fast reconstruction (including digital phase unwrapping) of off-axis interferograms, which allow real-time processing in more than video rate on regular single-core computers.
Off-axis digital holographic microscopy with LED illumination based on polarization filtering.
Guo, Rongli; Yao, Baoli; Gao, Peng; Min, Junwei; Zhou, Meiling; Han, Jun; Yu, Xun; Yu, Xianghua; Lei, Ming; Yan, Shaohui; Yang, Yanlong; Dan, Dan; Ye, Tong
2013-12-01
A reflection mode digital holographic microscope with light emitting diode (LED) illumination and off-axis interferometry is proposed. The setup is comprised of a Linnik interferometer and a grating-based 4f imaging unit. Both object and reference waves travel coaxially and are split into multiple diffraction orders in the Fourier plane by the grating. The zeroth and first orders are filtered by a polarizing array to select orthogonally polarized object waves and reference waves. Subsequently, the object and reference waves are combined again in the output plane of the 4f system, and then the hologram with uniform contrast over the entire field of view can be acquired with the aid of a polarizer. The one-shot nature in the off-axis configuration enables an interferometric recording time on a millisecond scale. The validity of the proposed setup is illustrated by imaging nanostructured substrates, and the experimental results demonstrate that the phase noise is reduced drastically by an order of 68% when compared to a He-Ne laser-based result.
Rotorcraft flight control design using quantitative feedback theory and dynamic crossfeeds
NASA Technical Reports Server (NTRS)
Cheng, Rendy P.
1995-01-01
A multi-input, multi-output controls design with robust crossfeeds is presented for a rotorcraft in near-hovering flight using quantitative feedback theory (QFT). Decoupling criteria are developed for dynamic crossfeed design and implementation. Frequency dependent performance metrics focusing on piloted flight are developed and tested on 23 flight configurations. The metrics show that the resulting design is superior to alternative control system designs using conventional fixed-gain crossfeeds and to feedback-only designs which rely on high gains to suppress undesired off-axis responses. The use of dynamic, robust crossfeeds prior to the QFT design reduces the magnitude of required feedback gain and results in performance that meets current handling qualities specifications relative to the decoupling of off-axis responses. The combined effect of the QFT feedback design following the implementation of low-order, dynamic crossfeed compensator successfully decouples ten of twelve off-axis channels. For the other two channels it was not possible to find a single, low-order crossfeed that was effective.
Measurement of multiaxial ply strength by an off-axis flexure test
NASA Technical Reports Server (NTRS)
Crews, John H., Jr.; Naik, Rajiv A.
1992-01-01
An off-axis flexure (OAF) test was performed to measure ply strength under multiaxial stress states. This test involves unidirectional off-axis specimens loaded in bending, using an apparatus that allows these anisotropic specimens to twist as well as flex without the complications of a resisting torque. A 3D finite element stress analysis verified that simple beam theory could be used to compute the specimen bending stresses at failure. Unidirectional graphite/epoxy specimens with fiber angles ranging from 90 deg to 15 deg have combined normal and shear stresses on their failure planes that are typical of 45 deg plies in structural laminates. Tests for a range of stress states with AS4/3501-6 specimens showed that both normal and shear stresses on the failure plane influenced cracking resistance. This OAF test may prove to be useful for generating data needed to predict ply cracking in composite structures and may also provide an approach for studying fiber-matrix interface failures under stress states typical of structures.
NASA Astrophysics Data System (ADS)
Gries, Katharina Ines; Schlechtweg, Julian; Hille, Pascal; Schörmann, Jörg; Eickhoff, Martin; Volz, Kerstin
2017-10-01
Scanning transmission electron microscopy is an extremely useful method to image small features with a size in the range of a few nanometers and below. But it must be taken into account that such images are projections of the sample and do not necessarily represent the real three dimensional structure of the specimen. By applying electron tomography this problem can be overcome. In our work GaN nanowires including InGaN nanodisks were investigated. To reduce the effect of the missing wedge a single nanowire was removed from the underlying silicon substrate using a manipulator needle and attached to a tomography holder. Since this sample exhibits the same thickness of few tens of nanometers in all directions normal to the tilt axis, this procedure allows a sample tilt of ±90°. Reconstruction of the received data reveals a split of the InGaN nanodisks into a horizontal continuation of the (0 0 0 1 bar) central facet and a declined {1 0 1 bar l} facet (with l = -2 or -3).
A geometric model of a V-slit Sun sensor correcting for spacecraft wobble
NASA Technical Reports Server (NTRS)
Mcmartin, W. P.; Gambhir, S. S.
1994-01-01
A V-Slit sun sensor is body-mounted on a spin-stabilized spacecraft. During injection from a parking or transfer orbit to some final orbit, the spacecraft may not be dynamically balanced. This may result in wobble about the spacecraft spin axis as the spin axis may not be aligned with the spacecraft's axis of symmetry. While the widely used models in Spacecraft Attitude Determination and Control, edited by Wertz, correct for separation, elevation, and azimuthal mounting biases, spacecraft wobble is not taken into consideration. A geometric approach is used to develop a method for measurement of the sun angle which corrects for the magnitude and phase of spacecraft wobble. The algorithm was implemented using a set of standard mathematical routines for spherical geometry on a unit sphere.
NASA Astrophysics Data System (ADS)
Yem, Lionel Mbida; Camera, Laurent; Mascle, Jean; Ribodetti, Alessandra
2011-04-01
Off northwest Libya the Cyrenaica foreland basin domain and its Pan-African continental crust, which constitute the African promontory, are overthrusted by the Mediterranean Ridge Complex. The thrust belt contact and its seismic stratigraphy have been analysed using pre-stack depth-migrated multichannel seismic (MCS) lines recorded during the MEDISIS survey (2002). The geometry and sedimentary distribution analysis through the wedge-top depocentres allow reconstruction of schematic cross-sections of the tectono-sedimentary wedge that includes two major thrust sequences separated by an apparently poorly deformed transition zone. Based on time-space variation of several piggyback basins, we propose that these thrust sequences relate to distinct phases of shortening. (1) A first event, which probably occurred just prior to the Messinian crisis in latest Miocene (Tortonian times?) and (2) A second event, that has finally led to the present-day overthrusting of the Mediterranean Ridge over the Libyan continental slope.
Verlis, K M; Campbell, M L; Wilson, S P
2013-07-15
We present the first evidence of ingestion of plastic by seabirds from the southern Great Barrier Reef (GBR), Australia. The occurrence of marine debris ingestion in the wedge-tailed shearwater, Ardenna pacifica, on Heron Island was the focus of this preliminary research. Our findings indicate that 21% of surveyed chicks are fed plastic fragments by their parents, having ingested 3.2 fragments on average. The most common colours of ingested plastic fragments were off/white (37.5%) and green (31.3%). Ingested fragments had a mean size of 10.17±4.55 mm and a mean weight of 0.056±0.051 g. Our results indicate that further research is critical to understanding the extent of ingestion, colour preferences, and what impacts ingestion may have on these and other seabird populations in the GBR. Copyright © 2013 Elsevier Ltd. All rights reserved.
What's the point? Hole-ography in Poincaré AdS
NASA Astrophysics Data System (ADS)
Espíndola, Ricardo; Güijosa, Alberto; Landetta, Alberto; Pedraza, Juan F.
2018-01-01
In the context of the AdS/CFT correspondence, we study bulk reconstruction of the Poincaré wedge of AdS_3 via hole-ography, i.e., in terms of differential entropy of the dual CFT_2. Previous work had considered the reconstruction of closed or open spacelike curves in global AdS, and of infinitely extended spacelike curves in Poincaré AdS that are subject to a periodicity condition at infinity. Working first at constant time, we find that a closed curve in Poincaré is described in the CFT by a family of intervals that covers the spatial axis at least twice. We also show how to reconstruct open curves, points and distances, and obtain a CFT action whose extremization leads to bulk points. We then generalize all of these results to the case of curves that vary in time, and discover that generic curves have segments that cannot be reconstructed using the standard hole-ographic construction. This happens because, for the nonreconstructible segments, the tangent geodesics fail to be fully contained within the Poincaré wedge. We show that a previously discovered variant of the hole-ographic method allows us to overcome this challenge, by reorienting the geodesics touching the bulk curve to ensure that they all remain within the wedge. Our conclusion is that all spacelike curves in Poincaré AdS can be completely reconstructed with CFT data, and each curve has in fact an infinite number of representations within the CFT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santos-Villalobos, Hector J; Barstow, Del R; Karakaya, Mahmut
Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method usesmore » an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.« less
Geophysical and Geochemical Analysis of the 8°20' N Seamount Chain: Studies of Off-Axis Volcanism
NASA Astrophysics Data System (ADS)
McCully, E.; Fornari, D. J.; Gregg, P. M.; Perfit, M. R.; Wanless, V. D.; Anderson, M.; Lubetkin, M.
2017-12-01
The 8°20' N Seamount Chain is an off-axis lineament of volcanoes located west of the East Pacific Rise (EPR) and 15 km north of the Siqueiros Fracture Zone. The volcanoes are located 11 km west of the EPR axis and extend 160 km to the west. The OASIS (Off-Axis Seamount Investigations at Siqueiros) expedition in November 2016 collected ship-based EM122 bathymetry aboard the R/V Atlantis over the entire seamount chain at a 50 m resolution, and AUV Sentry bathymetric and sidescan sonar data were collected over 11 selected areas on some of the seamount summits and flanks at 1-2 m resolution. 90,000 high-resolution digital images were acquired using DSV Alvin and analyzed and classified according to morphology, structure, sediment and manganese presence, and biology. These data are used to create geologic facies maps to correlate seafloor morphology and type with acoustic reflectivity. Major and trace element data of samples collected by Alvin and dredging are also correlated to geological parameters of the seafloor features on each studied seamount. Initial estimates for the volumes of individual constructional features (e.g., mounds, cones) that comprise the seamounts were derived from the high-resolution EM122 multibeam and Sentry AUV bathymetric data and calculated using IVS Fledermaus and plotted as a function of distance from the EPR. These individually constructed volcanic features, dependent on geochemical diversity, may ultimately be grouped into larger eruptive volumes. Thus far, Sentry-derived volumes range from 0.0011-2.96 km3, while EM122-derived volumes range from 0.13-123 km3. The seamounts were classified into 3 shapes; circular, volcanic lineaments aligning parallel to the ridge-axis, and ridge-like constructions, trending perpendicular to the EPR axis. The central 60 km of the chain (60-120 km off-axis) is dominated by ridges and circular seamounts, which exhibit the largest volumes observed along the 8°20' N chain. The seamounts with the lowest volumes are observed in the eastern-most 50 km of the lineament, nearest to the ridge axis. Future work includes distinguishing monogenetic and polygenetic cones and better quantifying how many eruptive periods occurred to form the present seamount morphology.
Resolving the Shell of the Superbubble 30 Doradus C with Chandra
NASA Astrophysics Data System (ADS)
Lopez, Laura
2017-09-01
We propose to observe the superbubble (SB) 30 Doradus C (30 Dor C) with ACIS-S for 100 ks to resolve and characterize the non-thermal shell, point sources, and the young supernova remnant (SNR) J0536 6913 at sub-arcsecond scales. 30 Dor C has been imaged off axis repeatedly by Chandra due to its proximity to SN 1987A, but the majority of the shell has only been observed <20 ks at off-axis distances of >10 arcminutes. The on-axis spatial resolution, sensitivity, and low background of ACIS-S are necessary to disentangle point sources from diffuse emission, to localize synchrotron filaments associated with accelerated electrons, and to investigate the SNR J0536 6913.
Sannomiya, Takumi; Sawada, Hidetaka; Nakamichi, Tomohiro; Hosokawa, Fumio; Nakamura, Yoshio; Tanishiro, Yasumasa; Takayanagi, Kunio
2013-12-01
A generic method to determine the aberration center is established, which can be utilized for aberration calculation and axis alignment for aberration corrected electron microscopes. In this method, decentering induced secondary aberrations from inherent primary aberrations are minimized to find the appropriate axis center. The fitness function to find the optimal decentering vector for the axis was defined as a sum of decentering induced secondary aberrations with properly distributed weight values according to the aberration order. Since the appropriate decentering vector is determined from the aberration values calculated at an arbitrary center axis, only one aberration measurement is in principle required to find the center, resulting in /very fast center search. This approach was tested for the Ronchigram based aberration calculation method for aberration corrected scanning transmission electron microscopy. Both in simulation and in experiments, the center search was confirmed to work well although the convergence to find the best axis becomes slower with larger primary aberrations. Such aberration center determination is expected to fully automatize the aberration correction procedures, which used to require pre-alignment of experienced users. This approach is also applicable to automated aperture positioning. Copyright © 2013 Elsevier B.V. All rights reserved.
Curved VPH gratings for novel spectrographs
NASA Astrophysics Data System (ADS)
Clemens, J. Christopher; O'Donoghue, Darragh; Dunlap, Bart H.
2014-07-01
The introduction of volume phase holographic (VPH) gratings into astronomy over a decade ago opened new possibilities for instrument designers. In this paper we describe an extension of VPH grating technology that will have applications in astronomy and beyond: curved VPH gratings. These devices can disperse light while simultaneously correcting aberrations. We have designed and manufactured two different kinds of convex VPH grating prototypes for use in off-axis reflecting spectrographs. One type functions in transmission and the other in reflection, enabling Offnerstyle spectrographs with the high-efficiency and low-cost advantages of VPH gratings. We will discuss the design process and the tools required for modelling these gratings along with the recording layout and process steps required to fabricate them. We will present performance data for the first convex VPH grating produced for an astronomical spectrograph.
Using artificial neural networks (ANN) for open-loop tomography
NASA Astrophysics Data System (ADS)
Osborn, James; De Cos Juez, Francisco Javier; Guzman, Dani; Butterley, Timothy; Myers, Richard; Guesalaga, Andres; Laine, Jesus
2011-09-01
The next generation of adaptive optics (AO) systems require tomographic techniques in order to correct for atmospheric turbulence along lines of sight separated from the guide stars. Multi-object adaptive optics (MOAO) is one such technique. Here, we present a method which uses an artificial neural network (ANN) to reconstruct the target phase given off-axis references sources. This method does not require any input of the turbulence profile and is therefore less susceptible to changing conditions than some existing methods. We compare our ANN method with a standard least squares type matrix multiplication method (MVM) in simulation and find that the tomographic error is similar to the MVM method. In changing conditions the tomographic error increases for MVM but remains constant with the ANN model and no large matrix inversions are required.
Solar C: Scatter-Free Observatory for Limb Active Regions and Coronae
NASA Technical Reports Server (NTRS)
2004-01-01
The SOLARC observatory is a 0.5m off-axis reflecting coronagraph. NASA SRT funding has allowed the completion of this telescope facility, which we believe is now the world's largest operational coronagraph. We have achieved our proposal goals both in the development of the new technology for this facility and in the demonstration of its scientific and educational potential: 1) The SOLARC engineering development was successful and has spawned other similar instruments. The off-axis design of ATST (a new 4m telescope) has benefited from the SOLARC development. The off-axis 1.6m NST facility at BBSO is also now under construction and will be the world's largest solar disk observing telescope until ATST is completed. Both of these telescope designs are derivatives of the SOLARC 0.5m off-axis. Some of this technical development is described in the publications. 2) The most important scientific goal of SOLARC has been to demonstrate that coronal magnetic fields can be measured using infrared spectropolarimetry techniques. With the completion of the optical fiber-bundle imaging spectropolarimeter we have measured the coronal field strength with a sensitivity to the line-of-sight field component of 2G at 150,OOOkm above the limb. We believe this capability opens new opportunities for space weather, and coronal physics research. In particular we have demonstrated a new tool for understanding the effect of the Sun on the terrestrial space environment. A paper reporting these results has recently been submitted to the Astrophysical Journal Letters.
NASA Astrophysics Data System (ADS)
Tobin, Harold; Hirose, Takehiro; Demian, Saffer
2014-05-01
IODP Site C0002 at the Nankai Trough is now the deepest hole ever drilled in scientific ocean drilling, at 3058 meters below sea floor so far, and the first hole anywhere to access the deep interior of an active convergent margin. Site C0002 is part of the NanTroSEIZE transect off the Kii-Kumano region of Japan, imaged with 3D seismic reflection and drilled on a series of Chikyu expeditions to shed light on the processes around the up-dip edge of seismogenic locking and slip. At Site C0002, riser drilling has passed through the approximately 900 m thick Kumano forearc basin and pierced the underlying Miocene age accretionary wedge. Limited coring, extensive LWD logging, and continuous observations on drill cuttings reveal the materials and processes in the deep interior of the inner wedge. Predominantly fine-grained mudstones with common turbiditic sands were encountered, complexly deformed and exhibiting well-developed scaly clay fabrics, variable bedding dip with very steep dips prevailing, and veins that become more abundant with depth. The biostratigraphic age of the sediments in the lowermost part of the hole is thought to be ~ 9 - 11 Ma, with an assumed age of accretion of 3-5 Ma. Physical properties suggest that the inner wedge from 1600 - 3000 mbsf has quite homogeneous properties. Evidence from borehole logging, drilling parameters, and samples for the state of stress and pore pressure in this never-before accessed tectonic environment will be presented.
Patkar, Sushil
2016-08-01
Unilateral anterior retropharyngeal approach was used in a case of basilar invagination with atlanto-axial instability. This approach provided easy access to both atlanto-axial joints. Wedge-shaped titanium cages were used to distract the joints and reduce the basilar invagination. Titanium plates with screws were used to fix the lateral mass of atlas with the body of axis, bilaterally. The anterior atlanto-axial joint distraction procedure has not been described in literature before seems to be an easy option in selected cases of craniovertebral anomalies and needs to be investigated by more surgeons.
Efficient photonic reformatting of celestial light for diffraction-limited spectroscopy
NASA Astrophysics Data System (ADS)
MacLachlan, D. G.; Harris, R. J.; Gris-Sánchez, I.; Morris, T. J.; Choudhury, D.; Gendron, E.; Basden, A. G.; Spaleniak, I.; Arriola, A.; Birks, T. A.; Allington-Smith, J. R.; Thomson, R. R.
2017-02-01
The spectral resolution of a dispersive astronomical spectrograph is limited by the trade-off between throughput and the width of the entrance slit. Photonic guided wave transitions have been proposed as a route to bypass this trade-off, by enabling the efficient reformatting of incoherent seeing-limited light collected by the telescope into a linear array of single modes: a pseudo-slit which is highly multimode in one axis but diffraction-limited in the dispersion axis of the spectrograph. It is anticipated that the size of a single-object spectrograph fed with light in this manner would be essentially independent of the telescope aperture size. A further anticipated benefit is that such spectrographs would be free of `modal noise', a phenomenon that occurs in high-resolution multimode fibre-fed spectrographs due to the coherent nature of the telescope point spread function (PSF). We seek to address these aspects by integrating a multicore fibre photonic lantern with an ultrafast laser inscribed three-dimensional waveguide interconnect to spatially reformat the modes within the PSF into a diffraction-limited pseudo-slit. Using the CANARY adaptive optics (AO) demonstrator on the William Herschel Telescope, and 1530 ± 80 nm stellar light, the device exhibits a transmission of 47-53 per cent depending upon the mode of AO correction applied. We also show the advantage of using AO to couple light into such a device by sampling only the core of the CANARY PSF. This result underscores the possibility that a fully optimized guided-wave device can be used with AO to provide efficient spectroscopy at high spectral resolution.
Laser Measurements Based for Volumetric Accuracy Improvement of Multi-axis Systems
NASA Astrophysics Data System (ADS)
Vladimir, Sokolov; Konstantin, Basalaev
The paper describes a new developed approach to CNC-controlled multi-axis systems geometric errors compensation based on optimal error correction strategy. Multi-axis CNC-controlled systems - machine-tools and CMM's are the basis of modern engineering industry. Similar design principles of both technological and measurement equipment allow usage of similar approaches to precision management. The approach based on geometric errors compensation are widely used at present time. The paper describes a system for compensation of geometric errors of multi-axis equipment based on the new approach. The hardware basis of the developed system is a multi-function laser interferometer. The principles of system's implementation, results of measurements and system's functioning simulation are described. The effectiveness of application of described principles to multi-axis equipment of different sizes and purposes for different machining directions and zones within workspace is presented. The concepts of optimal correction strategy is introduced and dynamic accuracy control is proposed.
Accuracy Improvement of Multi-Axis Systems Based on Laser Correction of Volumetric Geometric Errors
NASA Astrophysics Data System (ADS)
Teleshevsky, V. I.; Sokolov, V. A.; Pimushkin, Ya I.
2018-04-01
The article describes a volumetric geometric errors correction method for CNC- controlled multi-axis systems (machine-tools, CMMs etc.). The Kalman’s concept of “Control and Observation” is used. A versatile multi-function laser interferometer is used as Observer in order to measure machine’s error functions. A systematic error map of machine’s workspace is produced based on error functions measurements. The error map results into error correction strategy. The article proposes a new method of error correction strategy forming. The method is based on error distribution within machine’s workspace and a CNC-program postprocessor. The postprocessor provides minimal error values within maximal workspace zone. The results are confirmed by error correction of precision CNC machine-tools.
Fabrication and analysis of a micro-machined tri-axis gyroscope
NASA Astrophysics Data System (ADS)
Tsai, Nan-Chyuan; Sue, Chung-Yang
2008-11-01
This paper presents an innovative micro-gyroscope design. Solely by SOI (silicon on insulator) fabrication technology and wet etching, the proposed micro-gyroscope can be produced in batch and is capable of detecting three-axis angular rates. The induced motions of all individual seismic mass modules are designed to respond in the directions orthogonal to each other in order to decouple the obtained measurements. In our work, three pairs of high-resolution differential capacitors with signal processing circuits are employed to measure the angular velocity components in three axes. On the other hand, the drive electrode comb is used to constantly vibrate the outer-ring in the tangential direction by a sinusoidal voltage. The signal bandwidth is increased by distributed translational proof masses (DTPM), placed 90° apart orderly. Each individual proof mass of DTPM is designed with natural frequency discrepancy and constrained to move in the radial direction so that the superior mode matching can be easily, to some extent, achieved. The suspension flexures are particularly designed to resist planar displacements in the drive mode but increase the stroke of tilting angular displacement in the sense mode. By considering the complicated geometry of the suspension flexures, FEM (finite element method) is employed to examine the potential maximum induced mechanical stress. The dynamic equations of the proposed gyroscope are established so that the embedded gyroscopic effects are explicitly unveiled. More importantly, the efficacy of the drive and sense circuit modules are verified by commercial softwares Hspice and Multisim. By intensive computer simulations and preliminary experimental studies, the resolution, bandwidth and decoupling capability of the tri-axis gyroscope are expected to be fairly enhanced if a certain degree of trade-off is preset.Corrections were made to figure 5 in this article on 3 October 2008. The corrected electronic version is identical to the print version.
Wavefront control of high-power laser beams in the National Ignition Facility (NIF)
NASA Astrophysics Data System (ADS)
Zacharias, Richard A.; Bliss, Erlan S.; Winters, Scott; Sacks, Richard A.; Feldman, Mark; Grey, Andrew; Koch, Jeffrey A.; Stolz, Christopher J.; Toeppen, John S.; Van Atta, Lewis; Woods, Bruce W.
2000-04-01
The use of lasers as the driver for inertial confinement fusion and weapons physics experiments is based on their ability to produce high-energy short pulses in a beam with low divergence. Indeed, the focusability of high quality laser beams far exceeds alternate technologies and is a major factor in the rationale for building high power lasers for such applications. The National Ignition Facility (NIF) is a large, 192-beam, high-power laser facility under construction at the Lawrence Livermore National Laboratory for fusion and weapons physics experiments. Its uncorrected minimum focal spot size is limited by laser system aberrations. The NIF includes a Wavefront Control System to correct these aberrations to yield a focal spot small enough for its applications. Sources of aberrations to be corrected include prompt pump-induced distortions in the laser amplifiers, previous-shot thermal distortions, beam off-axis effects, and gravity, mounting, and coating-induced optic distortions. Aberrations from gas density variations and optic-manufacturing figure errors are also partially corrected. This paper provides an overview of the NIF Wavefront Control System and describes the target spot size performance improvement it affords. It describes provisions made to accommodate the NIF's high fluence (laser beam and flashlamp), large wavefront correction range, wavefront temporal bandwidth, temperature and humidity variations, cleanliness requirements, and exception handling requirements (e.g. wavefront out-of-limits conditions).
High tibial closing wedge osteotomy for medial compartment osteoarthrosis of knee
Tuli, SM; Kapoor, Varun
2008-01-01
Background: Most patients of symptomatic osteoarthrosis of knee are associated with varus malalignment that is causative or contributory to painful arthrosis. It is rational to correct the malalignment to transfer the functional load to the unaffected or less affected compartment of the knee to relieve symptoms. We report the outcome of a simple technique of high tibial osteotomy in the medial compartment osteoarthrosis of the knee. Materials and Methods: Between 1996 and 2004 we performed closing wedge osteotomy in 78 knees in 65 patients. The patients selected for osteotomy were symptomatic essentially due to medial compartment osteoarthrosis associated with moderate genu varum. Of the 19 patients who had bilateral symptomatic disease 11 opted for high tibial osteotomy of their second knee 1-3 years after the first operation. Preoperative grading of osteoarthrosis and postoperative function was assessed using Japanese Orthopaedic Association (JOA) rating scale. Results: At a minimum follow-up of 2 years (range 2-9 years) 6-10° of valgus correction at the site of osteotomy was maintained, there was significant relief of pain while walking, negotiating stairs, squatting and sitting cross-legged. Walking distance in all patients improved by two to four times their preoperative distance of 200-400 m. No patient lost any preoperative knee function. The mean JOA scoring improved from preoperative 54 (40-65) to 77 (55-85) at final follow-up. Conclusion: Closing wedge high tibial osteotomy performed by our technique can be undertaken in any setup with moderate facilities. Operation related complications are minimal and avoidable. Kirschner wire fixation is least likely to interfere with replacement surgery if it becomes necessary. PMID:19823659
Modeling of roll/pitch determination with horizon sensors - Oblate Earth
NASA Astrophysics Data System (ADS)
Hablani, Hari B.
Model calculations are presented of roll/pitch determinations for oblate Earth, with horizon sensors. Two arrangements of a pair of horizon sensors are considered: left and right of the velocity vactor (i.e., along the pitch axis), and aft and forward (along the roll axis). Two approaches are used to obtain the roll/pitch oblateness corrections: (1) the crossing point approach, where the two crossings of the horizon sensor's scan and the earth's horizon are determined, and (2) by decomposing the angular deviation of the geocentric normal from the geodetic normal into roll and pitch components. It is shown that the two approaches yield essentially the same corrections if two sensors are used simultaneously. However, if the spacecraft is outfitted with only one sensor, the oblateness correction about one axis is far different from that predicted by the geocentric/geodetic angular deviation approach. In this case, the corrections may be calculated on ground for the sensor location under consideration and stored in the flight computer, using the crossing point approach.
NASA Astrophysics Data System (ADS)
Meigs, Andrew
2014-05-01
Critical taper wedge theory is the gold standard by which climate control of convergent orogenic belts is inferred. The theory predicts (and models reproduce) that an orogenic belt narrows if erosion increases in erosion in the face of a constant tectonic influx. Numerous papers now argue on the basis of thermochronologic data that the Chugach/ St. Elias Range (CSE) of southern Alaska narrowed as a direct response to Quaternary climate change because glaciers dominated erosion of the orogenic belt. The CSE formed in response to collision of a microplate with North America and is notable because glacial erosion has dominated the CSE for the past 5 to 6 Ma. An increase in sediment accumulation rates in the foreland basin over that time suggests that glacial erosion become more efficient. If correct, it is possible that glacial erosion outpaced rock influx thereby inducing a climatically controlled narrowing of the orogenic wedge during the Quaternary. Growth strata preserved within the wedge provide a test of that interpretation because they demonstrate the spatial and temporal pattern of deformation during the Pliocene to Quaternary climate transition. A thrust front established between 6 and 5 Ma jumped towards the foreland by 30 and 15 km at 1.8 and 0.25 Ma, respectively. Distributed deformation within the thrust belt accompanied the thrust front relocations. Continuous exhumation recorded by low-temperature thermochronometers occurred contemporaneously with the shortening, parallel the structural not the topographic grain, and ages become younger towards the foreland as well. Interpreted in terms of critical wedge theory, continuous distributed deformation reflects a sub-critical wedge taper resulting from the combined effects of persistent exhumation and incremental accretion and orogenic widening via thrust front jumps into the undeformed foreland. Taper angle varies according to published cross-sections and ranges from 3 to 9 degrees. If the wedge oscillated about critical taper, a pore fluid ratio between 0.7 and 0.97 is suggested by range of taper angles. Thus, the thrust belt response to Pliocene to Quaternary climate change and a likely increase in glacial coverage is in fact the opposite of the expected response of a critical-taper wedge to an increase in hinterland erosion rate. The CSE hovered near critical taper throughout the Quaternary and the tectonic influx equaled or exceeded the erosional efflux, implying that glacial erosion was paced by, not independent of, tectonic rock uplift rate.
Development and Status of Cu Ball/Wedge Bonding in 2012
NASA Astrophysics Data System (ADS)
Schneider-Ramelow, Martin; Geißler, Ute; Schmitz, Stefan; Grübl, Wolfgang; Schuch, Bernhard
2013-03-01
Starting in the 1980s and continuing right into the last decade, a great deal of research has been published on Cu ball/wedge (Cu B/W) wire bonding. Despite this, the technology has not been established in industrial manufacturing to any meaningful extent. Only spikes in the price of Au, improvements in equipment and techniques, and better understanding of the Cu wire-bonding process have seen Cu B/W bonding become more widespread—initially primarily for consumer goods manufacturing. Cu wire bonding is now expected to soon be used for at least 20% of all ball/wedge-bonded components, and its utilization in more sophisticated applications is around the corner. In light of this progress, the present paper comprehensively reviews the existing literature on this topic and discusses wire-bonding materials, equipment, and tools in the ongoing development of Cu B/W bonding technology. Key bonding techniques, such as flame-off, how to prevent damage to the chip (cratering), and bond formation on various common chip and substrate finishes are also described. Furthermore, apart from discussing quality assessment of Cu wire bonds in the initial state, the paper also provides an overview of Cu bonding reliability, in particular regarding Cu balls on Al metalization at high temperatures and in humidity (including under the influence of halide ions).
Complex Anisotropic Structure of the Mantle Wedge Beneath Kamchatka Volcanoes
NASA Astrophysics Data System (ADS)
Levin, V.; Park, J.; Gordeev, E.; Droznin, D.
2002-12-01
A wedge of mantle material above the subducting lithospheric plate at a convergent margin is among the most dynamic environments of the Earth's interior. Deformation and transport of solid and volatile phases within this region control the fundamental process of elemental exchange between the surficial layers and the interior of the planet. A helpful property in the study of material deformation and transport within the upper mantle is seismic anisotropy, which may reflect both microscopic effects of preferentialy aligned crystals of olivine and orthopyroxene and macroscopic effects of systematic cracks, melt lenses, layering etc. Through the mapping of anisotropic properties within the mantle wedge we can establish patterns of deformation. Volatile content affects olivine alignment, so regions of anomalous volatile content may be evident. Indicators of seismic anisotropy commonly employed in upper mantle studies include shear wave birefringence and mode-conversion between compressional and shear body waves. When combined together, these techniques offer complementary constraints on the location and intensity of anisotropic properties. The eastern coast of southern Kamchatka overlies a vigorous convergent margin where the Pacific plate descends at a rate of almost 80 mm/yr towards the northwest. We extracted seismic anisotropy indicators from two data sets sensitive to the anisotropic properties of the uppermost mantle. Firstly, we evaluated teleseismic receiver functions for a number of sites, and found ample evidence for anisotropicaly-influenced P-to-S mode conversion. Secondly, we measured splitting in S waves of earthquakes with sources within the downgoing slab. The first set of observations provides constraints on the depth ranges where strong changes in anisotropic properties take place. The local splitting data provides constraints on the cumulative strength of anisotropic properties along specific pathways through the mantle wedge and possibly parts of the slab. To explain the vertical stratification of anisotropy implied from receiver functions, and the strong lateral dependence of shear-wave splitting observations, we cannot rely on simple models of mantle wedge behaviour e.g., olivine-crystal alignment through subduction-driven corner flow. Diverse mechanisms can contribute to the observed pattern of anisotropic properties, with volatiles likely being a key influence. For instance, we find evidence in favor of a slow-symmetry-axis anisotropy within the uppermost 10-20 km of the mantle wedge, implying either excessive hydration of the mantle or else a presence of systematically aligned volatile-filled cracks or lenses. Also, shear-wave splitting is weak beneath the Avachinsky-Koryaksky volcanic center, suggesting either vertical flow or the influence of volatiles and/or thermally-enhanced diffusion creep.
Stratified Volume Diffractive Optical Elements as Low-Mass Coherent Lidar Scanners
NASA Technical Reports Server (NTRS)
Chambers, Diana M.; Nordin, Gregory P.; Kavaya, Michael J.
1999-01-01
Transmissive scanning elements for coherent laser radar systems are typically optical wedges, or prisms, which deflect the lidar beam at a specified angle and are then rotated about the instrument optical axis to produce a scan pattern. The wedge is placed in the lidar optical system subsequent to a beam-expanding telescope, implying that it has the largest diameter of any element in the system. The combination of the wedge diameter and asymmetric profile result in the element having very large mass and, consequently, relatively large power consumption required for scanning. These two parameters, mass and power consumption, are among the instrument requirements which need to be minimized when designing a lidar for a space-borne platform. Reducing the scanner contributions in these areas will have a significant effect on the overall instrument specifications, Replacing the optical wedge with a diffraction grating on the surface of a thin substrate is a straight forward approach with potential to reduce the mass of the scanning element significantly. For example, the optical wedge that will be used for the SPAce Readiness Coherent Lidar Experiment (SPARCLE) is approximately 25 cm in diameter and is made from silicon with a wedge angle designed for 30 degree deflection of a beam operating at approx. 2 micrometer wavelength. The mass of this element could be reduced by a factor of four by instead using a fused silica substrate, 1 cm thick, with a grating fabricated on one of the surfaces. For a grating to deflect a beam with a 2 micrometer wavelength by 30 degrees, a period of approximately 4 micrometers is required. This is small enough that fabrication of appropriate high efficiency blazed or multi-phase level diffractive optical gratings is prohibitively difficult. Moreover, bulk or stratified volume holographic approaches appear impractical due to materials limitations at 2 micrometers and the need to maintain adequate wavefront quality. In order to avoid the difficulties encountered in these approaches, we have developed a new type of high-efficiency grating which we call a Stratified Volume Diffractive Optical Element (SVDOE). The features of the gratings in this approach can be easily fabricated using standard photolithography and etching techniques and the materials used in the grating can be chosen specifically for a given application, In this paper we will briefly discuss the SVDOE technique and will present an example design of a lidar scanner using this approach. We will also discuss performance predictions for the example design.
Wide-field-of-view millimeter-wave telescope design with ultra-low cross-polarization
NASA Astrophysics Data System (ADS)
Bernacki, Bruce E.; Kelly, James F.; Sheen, David; Hatchell, Brian; Valdez, Patrick; Tedeschi, Jonathan; Hall, Thomas; McMakin, Douglas
2012-06-01
As millimeter-wave arrays become available, off-axis imaging performance of the fore optics increases in importance due to the relatively large physical extent of the arrays. Typically, simple optical telescope designs are adapted to millimeter-wave imaging but single-mirror spherical or classic conic designs cannot deliver adequate image quality except near the optical axis. Since millimeter-wave designs are quasi-optical, optical ray tracing and commercial design software can be used to optimize designs to improve off-axis imaging as well as minimize cross-polarization. Methods that obey the Dragone-Mizuguchi condition for the design of reflective millimeter-wave telescopes with low cross-polarization also provide additional degrees of freedom that offer larger fields of view than possible with single-reflector designs. Dragone's graphical design method does not lend itself readily to computer-based optical design approaches, but subsequent authors expanded on Dragone's geometric design approach with analytic expressions that describe the location, shape, off-axis height and tilt of the telescope elements that satisfy Dragone's design rules and can be used as a first-order design for subsequent computer-based design and optimization. We investigate two design variants that obey the Dragone-Mizuguchi conditions that exhibit ultra-low cross-polarization and a large diffraction-limited field of view well suited to millimeter-wave imaging arrays.
NASA Astrophysics Data System (ADS)
Yadav, Sonu; Ghosh, Soumen; Bose, Sayak; Barada, Kshitish K.; Pal, Rabindranath; Chattopadhyay, Prabal K.
2018-04-01
Experimentally, the density profile in the magnetic nozzle of a helicon antenna based plasma device is seen to be modified from being centrally peaked to that of hollow nature as the external magnetic field is increased. It occurs above a characteristic field value when the ions become magnetized in the expansion chamber. The density profile in the source chamber behind the nozzle, however, remains peaked on-axis irrespective of the magnetic field. The electron temperature there is observed to be hollow and this nature is carried to the expansion chamber along the field line. In the electron energy distribution near the off axis peak location, a high energy tail exists. Rotation of these tail electrons in the azimuthal direction due to the gradient-B drift in the expansion chamber leads to an additional off-axis ionization and forms the hollow density profile. It seems that if the ions are not magnetized, then the off-axially produced additional plasma is not confined and the density profile retains the on-axis peak nature. The present experiment successfully demonstrates how the knowledge of the ion magnetization together with tail electrons significantly contributes to the design of an efficient helicon plasma based thruster.
Design and manufacture of 8.4 m primary mirror segments and supports for the GMT
NASA Astrophysics Data System (ADS)
Martin, H. M.; Angel, J. R. P.; Burge, J. H.; Cuerden, B.; Davison, W. B.; Johns, M.; Kingsley, J. S.; Kot, L. B.; Lutz, R. D.; Miller, S. M.; Shectman, S. A.; Strittmatter, P. A.; Zhao, C.
2006-06-01
The design, manufacture and support of the primary mirror segments for the GMT build on the successful primary mirror systems of the MMT, Magellan and Large Binocular telescopes. The mirror segment and its support system are based on a proven design, and the experience gained in the existing telescopes has led to significant refinements that will provide even better performance in the GMT. The first 8.4 m segment has been cast at the Steward Observatory Mirror Lab, and optical processing is underway. Measurement of the off-axis surface is the greatest challenge in the manufacture of the segments. A set of tests that meets the requirements has been defined and the concepts have been developed in some detail. The most critical parts of the tests have been demonstrated in the measurement of a 1.7 m off-axis prototype. The principal optical test is a full-aperture, high-resolution null test in which a hybrid reflective-diffractive null corrector compensates for the 14 mm aspheric departure of the off-axis segment. The mirror support uses the same synthetic floatation principle as the MMT, Magellan, and LBT mirrors. Refinements for GMT include 3-axis actuators to accommodate the varying orientations of segments in the telescope.
NASA Astrophysics Data System (ADS)
Zeng, Zhenxiang; Zheng, Huadong; Yu, Yingjie; Asundi, Anand K.
2017-06-01
A method for calculating off-axis phase-only holograms of three-dimensional (3D) object using accelerated point-based Fresnel diffraction algorithm (PB-FDA) is proposed. The complex amplitude of the object points on the z-axis in hologram plane is calculated using Fresnel diffraction formula, called principal complex amplitudes (PCAs). The complex amplitudes of those off-axis object points of the same depth can be obtained by 2D shifting of PCAs. In order to improve the calculating speed of the PB-FDA, the convolution operation based on fast Fourier transform (FFT) is used to calculate the holograms rather than using the point-by-point spatial 2D shifting of the PCAs. The shortest recording distance of the PB-FDA is analyzed in order to remove the influence of multiple-order images in reconstructed images. The optimal recording distance of the PB-FDA is also analyzed to improve the quality of reconstructed images. Numerical reconstructions and optical reconstructions with a phase-only spatial light modulator (SLM) show that holographic 3D display is feasible with the proposed algorithm. The proposed PB-FDA can also avoid the influence of the zero-order image introduced by SLM in optical reconstructed images.
Hamilton, T.S.; Enkin, Randolph J.; Riedel, Michael; Rogers, Gary C.; Pohlman, John W.; Benway, Heather M.
2015-01-01
Slipstream Slump, a well-preserved 3 km wide sedimentary failure from the frontal ridge of the Cascadia accretionary wedge 85 km off Vancouver Island, Canada, was sampled during Canadian Coast Guard Ship (CCGS) John P. Tully cruise 2008007PGC along a transect of five piston cores. Shipboard sediment analysis and physical property logging revealed 12 turbidites interbedded with thick hemipelagic sediments overlying the slumped glacial diamict. Despite the different sedimentary setting, atop the abyssal plain fan, this record is similar in number and age to the sequence of turbidites sampled farther to the south from channel systems along the Cascadia Subduction Zone, with no extra turbidites present in this local record. Given the regional physiographic and tectonic setting, megathrust earthquake shaking is the most likely trigger for both the initial slumping and subsequent turbidity currents, with sediments sourced exclusively from the exposed slump face of the frontal ridge. Planktonic foraminifera picked from the resedimented diamict of the underlying main slump have a disordered cluster of 14C ages between 12.8 and 14.5 ka BP. For the post-slump stratigraphy, an event-free depth scale is defined by removing the turbidite sediment intervals and using the hemipelagic sediments. Nine14C dates from the most foraminifera-rich intervals define a nearly constant hemipelagic sedimentation rate of 0.021 cm/year. The combined age model is defined using only planktonic foraminiferal dates and Bayesian analysis with a Poisson-process sedimentation model. The age model of ongoing hemipelagic sedimentation is strengthened by physical property correlations from Slipstream events to the turbidites for the Barkley Canyon site 40 km south. Additional modelling addressed the possibilities of seabed erosion or loss and basal erosion beneath turbidites. Neither of these approaches achieves a modern seabed age when applying the commonly used regional marine 14C reservoir age of 800 years (marine reservoir correction ΔR= 400 years). Rather, the top of the core appears to be 400 years in the future. A younger marine reservoir age of 400 years (ΔR = 0 years) brings the top to the present and produces better correlations with the nearby Effingham Inlet paleo-earthquake chronology based only on terrestrial carbon requiring no reservoir correction. The high-resolution dating and facies analysis of Slipstream Slump in this isolated slope basin setting demonstrates that this is also a useful type of sedimentary target for sampling the paleoseismic record in addition to the more studied turbidites from submarine canyon and channel systems. The first 10 turbidites at Slipstream Slump were deposited between 10.8 and 6.6 ka BP, after which the system became sediment starved and only two more turbidites were deposited. The recurrence interval for the inferred frequent early Holocene megathrust earthquakes is 460 ± 140 years, compatible with other estimates of paleoseismic megathrust earthquake occurrence rates along the subduction zone.
Analysis of dental supportive structures in orthodontic therapy.
Pavicin, Ivana Savić; Ivosević-Magdalenić, Natasa; Badel, Tomislav; Basić, Kresimir; Keros, Jadranka
2012-09-01
The purpose was to define the impact of orthodontic appliances on the density of the underlying dental bone tissue. Radiographic images of teeth were made in 27 study subjects before and twelve months after fixed orthodontic appliances were carried. The radiographs were digitalized and the levels of gray at sites where the greatest bone resorption was expected were transformed into optic density. In the standardization and comparison of values from the first and the second measurements the copper calibration wedge--a stepwedge--was used. Optic densities in the observed sites were compared with optic densities of the calibration wedge and expressed as their thickness equivalent. The study results showed no statistically significant difference in bone densities, indicating that the orthodontic therapy was properly planned and carried out and that excessive forces were not used in the applied correctional procedures.
NASA Astrophysics Data System (ADS)
Lu, Mark; Liang, Curtis; King, Dion; Melvin, Lawrence S., III
2005-11-01
Model-based Optical Proximity correction has become an indispensable tool for achieving wafer pattern to design fidelity at current manufacturing process nodes. Most model-based OPC is performed considering the nominal process condition, with limited consideration of through process manufacturing robustness. This study examines the use of off-target process models - models that represent non-nominal process states such as would occur with a dose or focus variation - to understands and manipulate the final pattern correction to a more process robust configuration. The study will first examine and validate the process of generating an off-target model, then examine the quality of the off-target model. Once the off-target model is proven, it will be used to demonstrate methods of generating process robust corrections. The concepts are demonstrated using a 0.13 μm logic gate process. Preliminary indications show success in both off-target model production and process robust corrections. With these off-target models as tools, mask production cycle times can be reduced.
Adaptive Changes in the Perception of Fast and Slow Movement at Different Head Positions.
Panichi, Roberto; Occhigrossi, Chiara; Ferraresi, Aldo; Faralli, Mario; Lucertini, Marco; Pettorossi, Vito E
2017-05-01
This paper examines the subjective sense of orientation during asymmetric body rotations in normal subjects. Self-motion perception was investigated in 10 healthy individuals during asymmetric whole-body rotation with different head orientations. Both on-vertical axis and off-vertical axis rotations were employed. Subjects tracked a remembered earth-fixed visual target while rotating in the dark for four cycles of asymmetric rotation (two half-sinusoidal cycles of the same amplitude, but of different duration). The rotations induced a bias in the perception of velocity (more pronounced with fast than with slow motion). At the end of rotation, a marked target position error (TPE) was present. For the on-vertical axis rotations, the TPE was no different if the rotations were performed with a 30° nose-down, a 60° nose-up, or a 90° side-down head tilt. With off-vertical axis rotations, the simultaneous activation of the semicircular canals and otolithic receptors produced a significant increase of TPE for all head positions. This difference between on-vertical and off-vertical axis rotation was probably partly due to the vestibular transfer function and partly due to different adaptation to the speed of rotation. Such a phenomenon might be generated in different components of the vestibular system. The adaptive process enhancing the perception of dynamic movement around the vertical axis is not related to the specific semicircular canals that are activated; the addition of an otolithic component results in a significant increase of the TPE.Panichi R, Occhigrossi C, Ferraresi A, Faralli M, Lucertini M, Pettorossi VE. Adaptive changes in the perception of fast and slow movement at different head positions. Aerosp Med Hum Perform. 2017; 88(5):463-468.
Design of an off-axis visual display based on a free-form projection screen to realize stereo vision
NASA Astrophysics Data System (ADS)
Zhao, Yuanming; Cui, Qingfeng; Piao, Mingxu; Zhao, Lidong
2017-10-01
A free-form projection screen is designed for an off-axis visual display, which shows great potential in applications such as flight training for providing both accommodation and convergence cues for pilots. The method based on point cloud is proposed for the design of the free-form surface, and the design of the point cloud is controlled by a program written in the macro-language. In the visual display based on the free-form projection screen, when the error of the screen along Z-axis is 1 mm, the error of visual distance at each filed is less than 1%. And the resolution of the design for full field is better than 1‧, which meet the requirement of resolution for human eyes.
NASA Astrophysics Data System (ADS)
Muniz, Sérgio R.; Bagnato, Vanderlei S.; Bhattacharya, M.
2015-06-01
In a region free of currents, magnetostatics can be described by the Laplace equation of a scalar magnetic potential, and one can apply the same methods commonly used in electrostatics. Here, we show how to calculate the general vector field inside a real (finite) solenoid, using only the magnitude of the field along the symmetry axis. Our method does not require integration or knowledge of the current distribution and is presented through practical examples, including a nonuniform finite solenoid used to produce cold atomic beams via laser cooling. These examples allow educators to discuss the nontrivial calculation of fields off-axis using concepts familiar to most students, while offering the opportunity to introduce themes of current modern research.
Efficiency of the DOMUS 750 vertical-axis wind turbine
NASA Astrophysics Data System (ADS)
Hallock, Kyle; Rasch, Tyler; Ju, Guoqiang; Alonso-Marroquin, Fernando
2017-06-01
The aim of this paper is to present some preliminary results on the efficiency of a wind turbine for an off-grid housing unit. To generate power, the unit uses a photovoltaic solar array and a vertical-axis wind turbine (VAWT). The existing VAWT was analysed to improve efficiency and increase power generation. There were found to be two main sources of inefficiency: 1. the 750W DC epicyclic generator performed poorly in low winds, and 2. the turbine blades wobbled, allowing for energy loss due to off-axis rotation. A 12V DC permanent magnet alternator was chosen that met the power requirements of the housing unit and would generate power at lower wind speeds. A support bracket was designed to prevent the turbine blades from wobbling.
NASA Technical Reports Server (NTRS)
Angelaki, D. E.; Hess, B. J.
1996-01-01
1. The dynamic contribution of otolith signals to three-dimensional angular vestibuloocular reflex (VOR) was studied during off-vertical axis rotations in rhesus monkeys. In an attempt to separate response components to head velocity from those to head position relative to gravity during low-frequency sinusoidal oscillations, large oscillation amplitudes were chosen such that peak-to-peak head displacements exceeded 360 degrees. Because the waveforms of head position and velocity differed in shape and frequency content, the particular head position and angular velocity sensitivity of otolith-ocular responses could be independently assessed. 2. During both constant velocity rotation and low-frequency sinusoidal oscillations, the otolith system generated two different types of oculomotor responses: 1) modulation of three-dimensional eye position and/or eye velocity as a function of head position relative to gravity, as presented in the preceding paper, and 2) slow-phase eye velocity as a function of head angular velocity. These two types of otolith-ocular responses have been analyzed separately. In this paper we focus on the angular velocity responses of the otolith system. 3. During constant velocity off-vertical axis rotations, a steady-state nystagmus was elicited that was maintained throughout rotation. During low-frequency sinusoidal off-vertical axis oscillations, dynamic otolith stimulation resulted primarily in a reduction of phase leads that characterize low-frequency VOR during earth-vertical axis rotations. Both of these effects are the result of an internally generated head angular velocity signal of otolithic origin that is coupled through a low-pass filter to the VOR. No change in either VOR gain or phase was observed at stimulus frequencies larger than 0.1 Hz. 4. The dynamic otolith contribution to low-frequency angular VOR exhibited three-dimensional response characteristics with some quantitative differences in the different response components. For horizontal VOR, the amplitude of the steady-state slow-phase velocity during constant velocity rotation and the reduction of phase leads during sinusoidal oscillation were relatively independent of tilt angle (for angles larger than approximately 10 degrees). For vertical and torsional VOR, the amplitude of steady-state slow-phase eye velocity during constant velocity rotation increased, and the phase leads during sinusoidal oscillation decreased with increasing tilt angle. The largest steady-state response amplitudes and smallest phase leads were observed during vertical/torsional VOR about an earth-horizontal axis. 5. The dynamic range of otolith-borne head angular velocity information in the VOR was limited to velocities up to approximately 110 degrees/s. Higher head velocities resulted in saturation and a decrease in the amplitude of the steady-state response components during constant velocity rotation and in increased phase leads during sinusoidal oscillations. 6. The response characteristics of otolith-borne angular VORs were also studied in animals after selective semicircular canal inactivation. Otolith angular VORs exhibited clear low-pass filtered properties with a corner frequency of approximately 0.05-0.1 Hz. Vectorial summation of canal VOR alone (elicited during earth-vertical axis rotations) and otolith VOR alone (elicited during off-vertical axis oscillations after semicircular canal inactivation) could not predict VOR gain and phase during off-vertical axis rotations in intact animals. This suggests a more complex interaction of semicircular canal and otolith signals. 7. The results of this study show that the primate low-frequency enhancement of VOR dynamics during off-vertical axis rotation is independent of a simultaneous activation of the vertical and torsional "tilt" otolith-ocular reflexes that have been characterized in the preceding paper. (ABSTRACT TRUNCATED).
Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.
Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle
2005-10-01
To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.
NASA Technical Reports Server (NTRS)
Morscher, Gregory N.; Yun, Hee Mann; DiCarlo, James A.
2007-01-01
The tensile mechanical properties of ceramic matrix composites (CMC) in directions off the primary axes of the reinforcing fibers are important for architectural design of CMC components that are subjected to multi-axial stress states. In this study, 2D-woven melt-infiltrated (MI) SiC/SiC composite panels with balanced fiber content in the 0 degree and 90 degree directions were tensile loaded in-plane in the 0 degree direction and at 45 degree to this direction. In addition, a 2D triaxially-braided MI composite panel with balanced fiber content in the plus or minus 67 degree bias directions and reduced fiber content in the axial direction was tensile loaded perpendicular to the axial direction tows (i.e., 23 degrees from the bias fibers). Stress-strain behavior, acoustic emission, and optical microscopy were used to quantify stress-dependent matrix cracking and ultimate strength in the panels. It was observed that both off-axis loaded panels displayed higher composite onset stresses for through-thickness matrix cracking than the 2D-woven 0/90 panels loaded in the primary 0 degree direction. These improvements for off-axis cracking strength can in part be attributed to higher effective fiber fractions in the loading direction, which in turn reduces internal stresses on critical matrix flaws for a given composite stress. Also for the 0/90 panel loaded in the 45 degree direction, an improved distribution of matrix flaws existed due to the absence of fiber tows perpendicular to the loading direction. In addition, for the +67/0/-67 braided panel, the axial tows perpendicular to the loading direction were not only low in volume fraction, but were also were well separated from one another. Both off-axis oriented panels also showed relatively good ultimate tensile strength when compared to other off-axis oriented composites in the literature, both on an absolute strength basis as well as when normalized by the average fiber strength within the composites. Initial implications are discussed for constituent and architecture design to improve the directional cracking of SiC/SiC CMC components with MI matrices.
Lupini, A.R.; de Jonge, N.
2012-01-01
Aberration-correction reduces the depth of field in scanning transmission electron microscopy (STEM) and thus allows three-dimensional imaging by depth-sectioning. This imaging mode offers the potential for sub-Ångstrom lateral resolution and nanometer-scale depth sensitivity. For biological samples, which may be many microns across and where high lateral resolution may not always be needed, optimizing the depth resolution even at the expense of lateral resolution may be desired, aiming to image through thick specimens. Although there has been extensive work examining and optimizing the probe formation in two-dimensions, there is less known about the probe shape along the optical axis. Here the probe shape is examined in three-dimensions in an attempt to better understand the depth-resolution in this mode. Examples are presented of how aberrations change the probe shape in three-dimensions, and it is found that off-axial aberrations may need to be considered for focal series of large areas. It is shown that oversized or annular apertures theoretically improve the vertical resolution for 3D imaging of nanoparticles. When imaging nanoparticles of several nanometer size, regular STEM can thereby be optimized such that the vertical full width at half maximum approaches that of the aberration corrected STEM with a standard aperture. PMID:21878149
Ziegler, Raphaela; Goebel, Lars; Seidel, Roland; Cucchiarini, Magali; Pape, Dietrich; Madry, Henning
2015-09-01
First, to evaluate whether medial open wedge high tibial osteotomy (HTO) induces alterations of the microstructure of the lateral tibial subchondral bone plate of sheep. Second, to test the hypothesis that specific correlations exist between topographical structural alterations of the subchondral bone, the cartilage and the lateral meniscus. Three experimental groups received biplanar osteotomies of the right proximal tibiae: (a) closing wedge HTO (4.5° of tibial varus), (b) opening wedge HTO (4.5° tibial valgus; standard correction) and (c) opening wedge HTO (9.5° of valgus; overcorrection), each of which was compared to the non-osteotomised contralateral proximal tibiae. After 6 months, subchondral bone structure indices were measured by computed tomography. Correlations between the subchondral bone, the articular cartilage and the lateral meniscus were determined. Increased loading by valgus overcorrection led to an enlarged specific bone surface (BS/BV) in the subarticular spongiosa compared with unloading by varisation. The subchondral bone plate was 3.9-fold thicker in the central region of the lateral tibial plateau than in the submeniscal periphery. Its thickness in the central region significantly correlated with the thickness of the articular cartilage. In the submeniscal region, such correlation did not exist. In general, a higher degree of osteoarthritis (OA) correlated with alterations of the subchondral bone plate microstructure. OA of the submeniscal articular cartilage also correlated with worse matrix staining of the lateral meniscus. Osteoarthritis changes are associated with alterations of the subchondral bone plate microstructure. Specific topographical relationships exist in the central region between the articular cartilage and subchondral bone plate thickness, and in the submeniscal periphery between and the articular cartilage and lateral meniscus. From a clinical perspective, the combined follow-up data from this and the previous two investigations suggest that open wedge valgus HTO is a safe procedure for the lateral compartment to manage medial osteoarthritis of the knee with varus malalignment in the short term.
NASA Astrophysics Data System (ADS)
Zhang, Yunfei; Huang, Wen; Zheng, Yongcheng; Ji, Fang; Xu, Min; Duan, Zhixin; Luo, Qing; Liu, Qian; Xiao, Hong
2016-03-01
Zinc sulfide is a kind of typical infrared optical material, commonly produced using single point diamond turning (SPDT). SPDT can efficiently produce zinc sulfide aspheric surfaces with micro-roughness and acceptable figure error. However the tool marks left by the diamond turning process cause high micro-roughness that degrades the optical performance when used in the visible region of the spectrum. Magnetorheological finishing (MRF) is a deterministic, sub-aperture polishing technology that is very helpful in improving both surface micro-roughness and surface figure.This paper mainly investigates the MRF technology of large aperture off-axis aspheric optical surfaces for zinc sulfide. The topological structure and coordinate transformation of a MRF machine tool PKC1200Q2 are analyzed and its kinematics is calculated, then the post-processing algorithm model of MRF for an optical lens is established. By taking the post-processing of off-axis aspheric surfacefor example, a post-processing algorithm that can be used for a raster tool path is deduced and the errors produced by the approximate treatment are analyzed. A polishing algorithm of trajectory planning and dwell time based on matrix equation and optimization theory is presented in this paper. Adopting this algorithm an experiment is performed to machining a large-aperture off-axis aspheric surface on the MRF machine developed by ourselves. After several times' polishing, the figure accuracy PV is proved from 3.3λ to 2.0λ and RMS from 0.451λ to 0.327λ. This algorithm is used to polish the other shapes including spheres, aspheres and prisms.
Production of internal transport barriers via self-generated mean flows in Alcator C-Moda)
NASA Astrophysics Data System (ADS)
Fiore, C. L.; Ernst, D. R.; Podpaly, Y. A.; Mikkelsen, D.; Howard, N. T.; Lee, Jungpyo; Reinke, M. L.; Rice, J. E.; Hughes, J. W.; Ma, Y.; Rowan, W. L.; Bespamyatnov, I.
2012-05-01
New results suggest that changes observed in the intrinsic toroidal rotation influence the internal transport barrier (ITB) formation in the Alcator C-Mod tokamak [E. S. Marmar and Alcator C-Mod group, Fusion Sci. Technol. 51, 261 (2007)]. These arise when the resonance for ion cyclotron range of frequencies (ICRF) minority heating is positioned off-axis at or outside of the plasma half-radius. These ITBs form in a reactor relevant regime, without particle or momentum injection, with Ti ≈ Te, and with monotonic q profiles (qmin < 1). C-Mod H-mode plasmas exhibit strong intrinsic co-current rotation that increases with increasing stored energy without external drive. When the resonance position is moved off-axis, the rotation decreases in the center of the plasma resulting in a radial toroidal rotation profile with a central well which deepens and moves farther off-axis when the ICRF resonance location reaches the plasma half-radius. This profile results in strong E × B shear (>1.5 × 105 rad/s) in the region where the ITB foot is observed. Gyrokinetic analyses indicate that this spontaneous shearing rate is comparable to the linear ion temperature gradient (ITG) growth rate at the ITB location and is sufficient to reduce the turbulent particle and energy transport. New and detailed measurement of the ion temperature demonstrates that the radial profile flattens as the ICRF resonance position moves off axis, decreasing the drive for the ITG the instability as well. These results are the first evidence that intrinsic rotation can affect confinement in ITB plasmas.
Bulk locality and quantum error correction in AdS/CFT
NASA Astrophysics Data System (ADS)
Almheiri, Ahmed; Dong, Xi; Harlow, Daniel
2015-04-01
We point out a connection between the emergence of bulk locality in AdS/CFT and the theory of quantum error correction. Bulk notions such as Bogoliubov transformations, location in the radial direction, and the holographic entropy bound all have natural CFT interpretations in the language of quantum error correction. We also show that the question of whether bulk operator reconstruction works only in the causal wedge or all the way to the extremal surface is related to the question of whether or not the quantum error correcting code realized by AdS/CFT is also a "quantum secret sharing scheme", and suggest a tensor network calculation that may settle the issue. Interestingly, the version of quantum error correction which is best suited to our analysis is the somewhat nonstandard "operator algebra quantum error correction" of Beny, Kempf, and Kribs. Our proposal gives a precise formulation of the idea of "subregion-subregion" duality in AdS/CFT, and clarifies the limits of its validity.
Axis: Generating Explanations at Scale with Learnersourcing and Machine Learning
ERIC Educational Resources Information Center
Williams, Joseph Jay; Kim, Juho; Rafferty, Anna; Heffernan, Neil; Maldonado, Samuel; Gajos, Krzysztof Z.; Lasecki, Walter S.; Heffernan, Neil
2016-01-01
While explanations may help people learn by providing information about why an answer is correct, many problems on online platforms lack high-quality explanations. This paper presents AXIS (Adaptive eXplanation Improvement System), a system for obtaining explanations. AXIS asks learners to generate, revise, and evaluate explanations as they solve…
Low-loss off-axis feeds for symmetric dual-reflector antennas
NASA Technical Reports Server (NTRS)
Veruttipong, T.; Galindo-Israel, V.; Imbriale, W.
1986-01-01
Circularly symmetric, dual reflector, high gain antenna systems often require feeds placed off the system's axis because of the need for multiple feeds to use the reflector antenna. Also, the constraint requiring the hyperboloid or shaped subreflector to remain circularly symmetric is sometimes added. In a Cassegrainian system, the subreflector and feed may be rotated off axis around the paraboloid focus and retain main reflector focusing. However, substantial spillover results in considerable noise with a high gain/low noise temperature system. In a shaped system, the tilt of the shaped subreflector and feed together results in substantial defocusing as well as spillover noise. If the subreflector is tilted approximately one-half the angle of the feed tilt in either the Cassegrainian or the dual shaped reflector antenna, it is found that spillover and noise are substantially reduced with tolerable defocusing. An extensive numerical analysis of these effects was conducted to determine the characteristics of a planned 70-meter, dual shaped reflector versus Cassegrainian antenna and to gain some understanding of the cause of the observed effects.
Measurement of vortex flow fields
NASA Technical Reports Server (NTRS)
Mcdevitt, T. Kevin; Ambur, Todd A.; Orngard, Gary M.; Owen, F. Kevin
1992-01-01
A 3-D laser fluorescence anemometer (LFA) was designed, built, and demonstrated for use in the Langley 16 x 24 inch Water Tunnel. Innovative optical design flexibility combined with compact and portable data acquisition and control systems were incorporated into the instrument. This will allow its use by NASA in other test facilities. A versatile fiber optic system facilities normal and off-axis laser beam alignment, removes mirror losses and improves laser safety. This added optical flexibility will also enable simple adaptation for use in the adjacent jet facility. New proprietary concepts in transmitting color separation, light collection, and novel prism separation of the scattered light was also designed and built into the system. Off-axis beam traverse and alignment complexity led to the requirement for a specialized, programmable transverse controller, and the inclusion of an additional traverse for the off-axis arm. To meet this challenge, an 'in-house' prototype unit was designed and built and traverse control software developed specifically for the water tunnel traverse applications. A specialized data acquisition interface was also required. This was designed and built for the LFA system.
White-light diffraction phase microscopy at doubled space-bandwidth product.
Shan, Mingguang; Kandel, Mikhail E; Majeed, Hassaan; Nastasa, Viorel; Popescu, Gabriel
2016-12-12
White light diffraction microscopy (wDPM) is a quantitative phase imaging method that benefits from both temporal and spatial phase sensitivity, granted, respectively, by the common-path geometry and white light illumination. However, like all off-axis quantitative phase imaging methods, wDPM is characterized by a reduced space-bandwidth product compared to phase shifting approaches. This happens essentially because the ultimate resolution of the image is governed by the period of the interferogram and not just the diffraction limit. As a result, off-axis techniques generates single-shot, i.e., high time-bandwidth, phase measurements, at the expense of either spatial resolution or field of view. Here, we show that combining phase-shifting and off-axis, the original space-bandwidth is preserved. Specifically, we developed phase-shifting diffraction phase microscopy with white light, in which we measure and combine two phase shifted interferograms. Due to the white light illumination, the phase images are characterized by low spatial noise, i.e., <1nm pathlength. We illustrate the operation of the instrument with test samples, blood cells, and unlabeled prostate tissue biopsy.
Harris, Breanna N; Carr, James A
2016-05-01
Maintaining energy balance and reproducing are important for fitness, yet animals have evolved mechanisms by which the hypothalamus-pituitary-adrenal/interrenal (HPA/HPI) axis can shut these activities off. While HPA/HPI axis inhibition of feeding and reproduction may have evolved as a predator defense, to date there has been no review across taxa of the causal evidence for such a relationship. Here we review the literature on this topic by addressing evidence for three predictions: that exposure to predators decreases reproduction and feeding, that exposure to predators activates the HPA/HPI axis, and that predator-induced activation of the HPA/HPI axis inhibits foraging and reproduction. Weight of evidence indicates that exposure to predator cues inhibits several aspects of foraging and reproduction. While the evidence from fish and mammals supports the hypothesis that predator cues activate the HPA/HPI axis, the existing data in other vertebrate taxa are equivocal. A causal role for the HPA axis in predator-induced suppression of feeding and reproduction has not been demonstrated to date, although many studies report correlative relationships between HPA activity and reproduction and/or feeding. Manipulation of HPA/HPI axis signaling will be required in future studies to demonstrate direct mediation of predator-induced inhibition of feeding and reproduction. Understanding the circuitry linking sensory pathways to their control of the HPA/HPI axis also is needed. Finally, the role that fear and anxiety pathways play in the response of the HPA axis to predator cues is needed to better understand the role that predators have played in shaping anxiety related behaviors in all species, including humans. Copyright © 2016 Elsevier Inc. All rights reserved.
Remote ballistic fractures in a gelatine model - aetiology and surgical implications
2013-01-01
Background Remote ballistic femoral fractures are rare fractures reported in the literature but still debated as to their existence and, indeed, their treatment. This study aimed to prove their existence, understand how they occur and determine which ammunition provides the greatest threat. In addition, fracture patterns, soft tissue disruption and contamination were assessed to aid in treatment planning. Method We filmed 42 deer femora embedded in ballistic gelatine and shot with four different military (5.56 × 45 mm, 7.62 × 39 mm) and civilian (9 × 19 mm, .44 in.) bullets, at varying distances off the bone (0–10 cm). Results Two remote ballistic fractures occurred, both with .44 in. hollow-point bullets shot 3 cm off the bone. These fractures occurred when the leading edge of the expanding temporary cavity impacted the femur's supracondylar region, producing a wedge-shaped fracture with an undisplaced limb, deceivingly giving the appearance of a spiral fracture. No communication was seen between the fracture and permanent cavity, despite the temporary cavity encasing the fracture and stripping periosteum from its base. Conclusion These fractures occur with civilian ammunition, but cannot prove their existence with military rounds. They result from the expanding temporary cavity affecting the weakest part of the bone, creating a potentially contaminated wedge-shaped fracture, important for surgeons considering operative intervention. PMID:23721113
Calibration of entrance dose measurement for an in vivo dosimetry programme.
Ding, W; Patterson, W; Tremethick, L; Joseph, D
1995-11-01
An increasing number of cancer treatment centres are using in vivo dosimetry as a quality assurance tool for verifying dosimetry as either the entrance or exit surface of the patient undergoing external beam radiotherapy. Equipment is usually limited to either thermoluminescent dosimeters (TLD) or semiconductor detectors such as p-type diodes. The semiconductor detector is more popular than the TLD due to the major advantage of real time analysis of the actual dose delivered. If a discrepancy is observed between the calculated and the measured entrance dose, it is possible to eliminate several likely sources of errors by immediately verifying all treatment parameters. Five Scanditronix EDP-10 p-type diodes were investigated to determine their calibration and relevant correction factors for entrance dose measurements using a Victoreen White Water-RW3 tissue equivalent phantom and a 6 MV photon beam from a Varian Clinac 2100C linear accelerator. Correction factors were determined for individual diodes for the following parameters: source to surface distance (SSD), collimator size, wedge, plate (tray) and temperature. The directional dependence of diode response was also investigated. The SSD correction factor (CSSD) was found to increase by approximately 3% over the range of SSD from 80 to 130 cm. The correction factor for collimator size (Cfield) also varied by approximately 3% between 5 x 5 and 40 x 40 cm2. The wedge correction factor (Cwedge) and plate correction factor (Cplate) were found to be a function of collimator size. Over the range of measurement, these factors varied by a maximum of 1 and 1.5%, respectively. The Cplate variation between the solid and the drilled plates under the same irradiation conditions was a maximum of 2.4%. The diode sensitivity demonstrated an increase with temperature. A maximum of 2.5% variation for the directional dependence of diode response was observed for angle of +/- 60 degrees. In conclusion, in vivo dosimetry is an important and reliable method for checking the dose delivered to the patient. Preclinical calibration and determination of the relevant correction factors for each diode are essential in order to achieve a high accuracy of dose delivered to the patient.
Evaluation of Hallux Valgus Correction With Versus Without Akin Proximal Phalanx Osteotomy.
Shibuya, Naohiro; Thorud, Jakob C; Martin, Lanster R; Plemmons, Britton S; Jupiter, Daniel C
2016-01-01
Although the efficacy of Akin proximal phalanx closing wedge osteotomy as a sole procedure for correction of hallux valgus deformity is questionable, when used in combination with other osseous corrective procedures, the procedure has been believed to be efficacious. However, a limited number of comparative studies have confirmed the value of this additional procedure. We identified patients who had undergone osseous hallux valgus correction with first metatarsal osteotomy or first tarsometatarsal joint arthrodesis with (n = 73) and without (n = 81) Akin osteotomy and evaluated their radiographic measurements at 3 points (preoperatively, within 3 months after surgery, and ≥6 months after surgery). We found that those people who had undergone the Akin procedure tended to have a larger hallux abduction angle and a more laterally deviated tibial sesamoid position preoperatively. Although the radiographic correction of the deformity was promising immediately after corrective surgery with the Akin osteotomy, maintenance of the correction was questionable in our cohort. The value of additional Akin osteotomy for correction of hallux valgus deformity is uncertain. Published by Elsevier Inc.
The Impact of Thoracoscopic Surgery on Payment and Health Care Utilization After Lung Resection.
Watson, Thomas J; Qiu, Jiejing
2016-04-01
Lung resection by video-assisted thoracoscopic surgery (VATS) is associated with multiple clinical benefits compared with resection by thoracotomy (OPEN). Less is known about reimbursements, costs, and resource use with each approach. This study used a commercial insurance claims database to examine differences between VATS and OPEN lung resections in payment, health care utilization, and estimated days off work for health care visits. All adult inpatient discharges for patients undergoing VATS or OPEN lung resection in 2010 were identified from the Truven MarketScan Database (Ann Arbor, MI). A total of 2,611 patients underwent lobectomy (VATS, 270; OPEN, 669) or wedge resection (VATS, 1,332; OPEN, 340). After adjustment, OPEN lobectomies had a longer length of stay (mean difference, 1.79 days) and higher payment to hospitals (mean difference, $3,497) and physicians (mean difference, $433) compared with VATS. Similar findings were noted after wedge resections. OPEN lobectomies had 1.28-times and 1.14-times more health care utilization days within 90 days and 365 days, respectively, after the operation compared with VATS, translating into increased expenditures of $3,260 at 90 days and $822 at 365 days for OPEN procedures. No significant differences in utilization were noted between OPEN and VATS wedge resections, except for fewer outpatient visits within 90 days in the OPEN group. Compared with an OPEN approach, lobectomy and wedge resection by VATS were associated with lower hospital and physician payments. In addition, lobectomy by VATS was associated with less health care utilization in the early postoperative period and during the first year after the operation. These payment and utilization reductions are important in an era of value-based purchasing in health care. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hill, M. E.; Mitchell, D. G.; McNutt, R. L., Jr.; Cooper, S.; Crew, A. B.; Dupont, A.; Hayes, J.; Hoffer, E.; Nelson, K.; Parker, C.; Schlemm, C., II; Seifert, H.; Stokes, M.; Angold, N. G.; McComas, D. J.; Weidner, S.; Wiedenbeck, M. E.
2016-12-01
The Solar Probe Plus (SPP) Mission's Integrated Science Investigation of the Sun (ISIS) is a suite of two energetic particle instruments, EPI-Lo and EPI-Hi, covering lower ( 10 keV-100 MeV) and higher ( 1-100 MeV/nuc) energies, respectively. The ISIS team will investigate the origins, acceleration, and transport of energetic particles in the corona and inner heliosphere during the planned 7-year, 24-orbit mission, with a perihelion initially of 0.16 AU (36 Solar radii; RS), the three final orbits reaching 0.044 AU (9.9 RS). EPI-Lo has a novel approach to obtaining large angular coverage, well-suited to 3-axis stabilized spacecraft such as SPP, by densely sampling its 2π steradian field of view with 80 apertures organized in eight matching, 10-aperture wedges. Each wedge relies primarily on time-of-flight (TOF) mass spectrometer techniques, employing thin secondary-electron-emitting foils, microchannel plates, and solid state detectors (SSDs), to measure ions from 50 keV - 15 MeV and electrons from 50-500 keV. Signal attenuation, absorbers, TOF-only measurements, and SSD-only techniques are used to extend this energy range higher and lower. In 2015 and 2016 we made measurements with engineering units and flight-spare EPI-Lo wedges at accelerators and with radioactive sources; in addition to presenting the instrument design, we will report the results from these tests to characterize the instrument's measurement performance.
Absolute stellar photometry on moderate-resolution FPA images
Stone, T.C.
2009-01-01
An extensive database of star (and Moon) images has been collected by the ground-based RObotic Lunar Observatory (ROLO) as part of the US Geological Survey program for lunar calibration. The stellar data are used to derive nightly atmospheric corrections for the observations from extinction measurements, and absolute calibration of the ROLO sensors is based on observations of Vega and published reference flux and spectrum data. The ROLO telescopes were designed for imaging the Moon at moderate resolution, thus imposing some limitations for the stellar photometry. Attaining accurate stellar photometry with the ROLO image data has required development of specialized processing techniques. A key consideration is consistency in discriminating the star core signal from the off-axis point spread function. The analysis and processing methods applied to the ROLO stellar image database are described. ?? 2009 BIPM and IOP Publishing Ltd.
Characterization of a high-purity germanium detector for small-animal SPECT
Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E
2011-01-01
We present an initial evaluation of a mechanically-cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axis. Finally, a flood-corrected-flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT. PMID:21852723
Johnson, Timothy J; Locascio, Laurie E
2002-08-01
Recently, a series of slanted wells on the floor of a microfluidic channel were experimentally shown to successfully induce off-axis transport and mixing of two confluent streams when operating under electroosmotic (EO) flow. This paper will further explore, through numerical simulations, the parameters that affect off-axis transport under EO flow with an emphasis on optimizing the mixing rate of (a). two confluent streams in steady-state or (b). the transient scenario of two confluent plugs of material, which simulates mixing after an injection. For the steady-state scenario, the degree of mixing was determined to increase by changing any of the following parameters: (1). increasing the well depth, (2). decreasing the well angle relative to the axis of the channel, and (3). increasing the EO mobility of the well walls relative to the mobility of the main channel. Also, it will be shown that folding of the fluid can occur when the well angle is sufficiently reduced and/or when the EO mobility of the wells is increased relative to the channel. The optimum configuration for the transient problem of mixing two confluent plugs includes shallow wells to minimize the well residence time, and an increased EO mobility of the well walls relative to the main channel as well as small well angles to maximize off-axis transport. The final design reported here for the transient study reduces the standard deviation of the concentration across the channel by 72% while only increasing the axial dispersion of the injected plug by 8.6 % when compared to a plug injected into a channel with no wells present. These results indicate that a series of slanted wells on the wall of a microchannel provides a means for controlling and achieving a high degree of off-axis transport and mixing in a passive manner for micro total analysis system (microTAS) devices that are driven by electroosmosis.
Linear and Non-Linear Response of Liquid and Solid Particles to Energetic Radiation
1991-03-11
for particle 2 located on the + x6 axis (perpendicular to the beam propagation axis) one diameter surface-to-surface from particle 1 (i 12 = 4.0, Obd2 ...axis direction. Off is the far field scattering angle relative to the beam propagation axis. Obd2 is the orientation angle of particle 2 relative to...Particle 2 in the Xb - Zb plane and positioned one diameter surface-to-surface from particle 1 (P12 = 4.0). a.) Obd2 = 00, b.) Obd2 = 30 ° , c.) ebd
Joseph, T K; Kartha, C P
1982-01-01
Centring of spectacle lenses is much neglected field of ophthalmology. The prismatic effect caused by wrong centring results in a phoria on the eye muscles which in turn causes persistent eyestrain. The theory of visual axis, optical axis and angle alpha is discussed. Using new methods the visual axis and optical axis of 35 subjects were measured. The results were computed for facial asymmetry, parallax error, angle alpha and also decentration for near vision. The results show that decentration is required on account of each of these factors. Considerable correction is needed in the vertical direction, a fact much neglected nowadays; and vertical decentration results in vertical phoria which is more symptomatic than horizontal phorias. Angle Alpha was computed for each of these patients. A new devise called 'The Kerala Decentration Meter' using the pinhole method for measuring the degree of decentration from the datum centre of the frame, and capable of correcting all the factors described above, is shown with diagrams.
Major off-axis hydrothermal activity on the northern Gorda Ridge
Rona, Peter A.; Denlinger, Roger P.; Fisk, M. R.; Howard, K. J.; Taghon, G. L.; Klitgord, Kim D.; McClain, James S.; McMurray, G. R.; Wiltshire, J. C.
1990-01-01
The first hydrothermal field on the northern Gorda Ridge, the Sea Cliff hydrothermal field, was discovered and geologic controls of hydrothermal activity in the rift valley were investigated on a dive series using the DSV Sea Cliff. The Sea Cliff hydrothermal field was discovered where predicted at the intersection of axis-oblique and axis-parallel faults at the south end of a linear ridge at mid-depth (2700 m) on the east wall. Preliminary mapping and sampling of the field reveal: a setting nested on nearly sediment-free fault blocks 300 m above the rift valley floor 2.6 km from the axis; a spectrum of venting types from seeps to black smokers; high conductive heat flow estimated to be equivalent to the convective flux of multiple black smokers through areas of the sea floor sealed by a caprock of elastic breccia primarily derived from basalt with siliceous cement and barite pore fillings; and a vent biota with Juan de Fuca Ridge affinites. These findings demonstrate the importance of off-axis hydrothermal activity and the role of the intersection of tectonic lineations in controlling hydrothermal sites at sea-floor spreading centers.
Parameswaran, Krishnan R; Rosen, David I; Allen, Mark G; Ganz, Alan M; Risby, Terence H
2009-02-01
Cavity-enhanced tunable diode laser absorption spectroscopy is an attractive method for measuring small concentrations of gaseous species. Ethane is a breath biomarker of lipid peroxidation initiated by reactive oxygen species. A noninvasive means of quickly quantifying oxidative stress status has the potential for broad clinical application. We present a simple, compact system using off-axis integrated cavity output spectroscopy with an interband cascade laser and demonstrate its use in real-time measurements of breath ethane. We demonstrate a detection sensitivity of 0.48 ppb/Hz(1/2).
Off-axis targets maximize bearing Fisher Information in broadband active sonar.
Kloepper, Laura N; Buck, John R; Liu, Yang; Nachtigall, Paul E
2018-01-01
Broadband active sonar systems estimate range from time delay and velocity from Doppler shift. Relatively little attention has been paid to how the received echo spectrum encodes information about the bearing of an object. This letter derives the bearing Fisher Information encoded in the frequency dependent transmitter beampattern. This leads to a counter-intuitive result: directing the sonar beam so that a target of interest is slightly off-axis maximizes the bearing information about the target. Beam aim data from a dolphin biosonar experiment agree closely with the angle predicted to maximize bearing information.
[Craniomandibular relations and anti-gravity posture: stabilometric study disclusion wedges].
Decocq, Philippe; Honoré, Jacques; Auclair-Assaad, Catherine; Sequeira, Henrique; Bocquet, Emmanuelle
2015-06-01
Cephalometric parameters are thought to influence static posture. The present work evaluates the relationships between skeletal class or facial divergency, on one hand, and body posture, on the other hand. ANB and FMA angles were measured from profile cephalograms in twenty healthy adults. From each, stabilograms were recorded, with eyes open or shut, and with or without disclusion splints. Without splints, ANB and FMA proved to correlate with the accuracy of postural control. Adding splints changes the average position of the center of pressure exerted on the ground by the body, the anterior-posterior axis, and this effect is consistent with that of the typology. It also alters the displacement of the center of pressure on the same axis. These effects depend on whether the eyes are open or closed. The data reinforces the notion of the impact of cephalometric parameters and their mechanical changes on the static posture. They invite us to take greater account of postural impact of splints used in orthodontic practice. © EDP Sciences, SFODF, 2015.
VizieR Online Data Catalog: ChaMP. I. First X-ray source catalog (Kim+, 2004)
NASA Astrophysics Data System (ADS)
Kim, D.-W.; Cameron, R. A.; Drake, J. J.; Evans, N. R.; Freeman, P.; Gaetz, T. J.; Ghosh, H.; Green, P. J.; Harnden, F. R. Jr; Karovska, M.; Kashyap, V.; Maksym, P. W.; Ratzlaff, P. W.; Schlegel, E. M.; Silverman, J. D.; Tananbaum, H. D.; Vikhlinin, A. A.; Wilkes, B. J.; Grimes, J. P.
2004-01-01
The Chandra Multiwavelength Project (ChaMP) is a wide-area (~14deg2 < survey of serendipitous Chandra X-ray sources, aiming to establish fair statistical samples covering a wide range of characteristics (such as absorbed active galactic nuclei, high-z clusters of galaxies) at flux levels (fX~10-15 to 10-14erg/s/cm2) ) intermediate between the Chandra deep surveys and previous missions. We present the first ChaMP catalog, which consists of 991 near on-axis, bright X-ray sources obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. To assess source reliability and positional uncertainty, we perform a series of simulations and also use Chandra data to complement the simulation study. The false source detection rate is found to be as good as or better than expected for a given limiting threshold. On the other hand, the chance of missing a real source is rather complex, depending on the source counts, off-axis distance (or PSF), and background rate. The positional error (95% confidence level) is usually less than 1" for a bright source, regardless of its off-axis distance, while it can be as large as 4" for a weak source (~20counts) at a large off-axis distance (Doff-axis>8'). We have also developed new methods to find spatially extended or temporary variable sources, and those sources are listed in the catalog. (5 data files).
Recent tectonics of the Mediterranean Ridge
NASA Astrophysics Data System (ADS)
Chamot-Rooke, N.; Rangin, C.; Kreemer, C.; Le Pichon, X.; Nielsen, C.; Pascal, G.; Rabaute, A.
2003-04-01
The present-day Eastern Mediterranean Sea is shaped by the progressive subduction of the deep Ionian, Herodotus and Levantine basins, all Mesozoic relics of the former Neo-Tethys Ocean. During the last decade, two major inputs improved our understanding of the tectonics of the area. On-land, extensive geodetic surveys confirmed that the recent kinematics involves slow northward motion of Africa with respect to Eurasia and rapid escape of the Anatolia microplate pushed aside by collision of Arabia along the Bitlis-Zagros suture. Offshore, geological and geophysical surveys revealed that continental fragments forming the rigid buttress, or backstop, onto which the Mediterranean Ridge is being built, floor part of the deep Mediterranean Sea. The rate of incorporation of Africa bearing sediments into the Mediterranean wedges (Calabrian prism and Mediterranean Ridge) is tightly controlled by upper plates motions (Calabria and Anatolia) with respect to Africa. The two wedges are presently growing at contrasting rates. Calabria has little motion whereas Anatolia/Aegea is rapidly rotating counterclockwise, implying high subduction rate off Peloponnesus and Crete. The space available for the wedges to grow is in turn controlled by the location and geometry of the leading edge of the Calabria and Anatolia/Aegea blocks, as well as the margin geometry of the northern African border. We discuss here the outline, structure and origin of the backstop in the light of recently acquired deep marine data: multibeam bathymetry, bottom reflectivity, deep seismic, gravity and magnetism. Based on a new mapping of the main active faults at sea combined with a new model of the crustal velocity field over the Eastern Mediterranean constrained by GPS, we show that shearing is essentially active at the wedge-backstop contact. Detailed mapping of a narrow, 500-km long belt of active mud volcanism offshore Peloponnesus and Crete, further shows that the wedge-backstop contact is also a major preferential fault conduit for massive mud extrusion. Observation and modelling thus suggest that shear partitioning, as a result of oblique subduction, is the dominant tectonic process, implying right-lateral slip for the western (Ionian) branch and left-lateral slip for the eastern (Herodotus) branch, both at a 2 cm/yr rate. Shearing is localized at the wedge-backstop contact, which is also the site for massive fluid expulsion.
NASA Astrophysics Data System (ADS)
Rowan, William L.; Bespamyatnov, Igor O.; Fiore, C. L.; Dominguez, A.; Hubbard, A. E.; Ince-Cushman, A.; Greenwald, M. J.; Lin, L.; Marmar, E. S.; Reinke, M.; Rice, J. E.; Zhurovich, K.
2007-11-01
Internal transport barrier (ITB) plasmas can arise spontaneously in Ohmic Alcator C-Mod plasmas. The operational prescription for the ITB include formation of an EDA H-mode in a toroidal magnetic field that is ramping down and a subsequent increase in the toroidal magnetic field. Like ITBs generated with off-axis ICRF heating, these have peaked pressure profiles which can be suppressed by on-axis ICRF heating. Recent work on onset conditions for the ICRF generated ITB (K. Zhurovich, et al., To be published in Nuclear Fusion) demonstrates that the broadening of the ion temperature profile due to off-axis ICRF reduces the ion temperature gradient and suppreses the ITG instability driven particle flux as the primary mechanism for ITB formation. The object of this study is to examine the characteristics of Ohmic ITBs to find whether this model for onset is supported.
NASA Technical Reports Server (NTRS)
Arnold, William, Sr.; Stahl, H Philip
2017-01-01
This design study was conducted to support the HABEX project. There are a number of companion papers at this conference which go into detail on what all the HABEX goals are. The objective of this paper is to establish a baseline primary mirror design which satisfies the following structural related requirements. The designs in this study have a high TRL (Technology Readiness Level), realistic manufacturing limits and performance in line with the HABEX mission. A secondary goal of the study was to evaluate a number competing criteria for the selection. Questions such as differences in the on axis versus off axis static and dynamic response to disturbances. This study concentrates on the structural behavior, companion papers cover thermal and long term stability aspects of the problem.
Ray, Mark D.; Sedlacek, Arthur J.
2003-08-19
A method and apparatus for remote, stand-off, and high efficiency spectroscopic detection of biological and chemical substances. The apparatus including an optical beam transmitter which transmits a beam having an axis of transmission to a target, the beam comprising at least a laser emission. An optical detector having an optical detection path to the target is provided for gathering optical information. The optical detection path has an axis of optical detection. A beam alignment device fixes the transmitter proximal to the detector and directs the beam to the target along the optical detection path such that the axis of transmission is within the optical detection path. Optical information gathered by the optical detector is analyzed by an analyzer which is operatively connected to the detector.
Horizontal Axis Levitron--A Physics Demonstration
ERIC Educational Resources Information Center
Michaelis, Max M.
2014-01-01
After a brief history of the Levitron, the first horizontal axis Levitron is reported. Because it is easy to operate, it lends itself to educational physics experiments and analogies. Precession and nutation are visualized by reflecting the beam from a laser pointer off the "spignet". Precession is fundamental to nuclear magnetic…
The ASTRO-H SXT Performance to the Large Off-Set Angles
NASA Technical Reports Server (NTRS)
Sato, Toshiki; Iizuka, Ryo; Mori, Hideyuki; Hayashi, Takayuki; Maeda, Yoshitomo; Ishida, Manabu; Kikuchi, Naomichi; Kurashima, Sho; Nakaniwa, Nozomi; Okajima, Takashi;
2016-01-01
The X-ray astronomy satellite ASTRO-H, which is the 6th Japanese X-ray astronomy satellite and is renamed Hitomi after launch, is designed to observe celestial X-ray objects in a wide energy band from a few hundred eV to 600 keV. The Soft X-ray Telescopes (SXTs) onboard ASTRO-H play a role of collecting and imaging X-rays up to approximately 12 keV. Although the field of view of the SXT is approximately 15' (FWHM), due to the thin-foil-nested Wolter-I type optics adopted in the SXTs, X-rays out of the field of view can reach the focal plane without experiencing a normal double reflection. This component is referred to as 'stray light'. Owing to investigation of the stray light so far, 'secondary reflection' is now identified as the main component of the stray light, which is composed of X-rays reflected only by secondary reflectors. In order to cut the secondary reflections, a 'pre-collimator' is equipped on top of the SXTs. However, we cannot cut all the stray lights with the pre-collimator in some off-axis angle domain. In this study, we measure the brightness of the stray light of the SXTs at some representative off-axis angles by using the ISAS X-ray beam line. ASTRO-H is equipped with two modules of the SXT; one is for the Soft X-ray Spectrometer (SXS), an X-ray calorimeter, and the other is for the Soft X-ray Imager (SXI), an X-ray CCD camera. These SXT modules are called SXT-S and SXT-I, respectively. Of the two detector systems, the SXI has a large field of view, a square with 38' on a side. To cope with this, we have made a mosaic mapping of the stray light at a representative off-axis angle of 30' in the X-ray beam line at the Institute of Space and Astronautical Science. The effective area of the brightest secondary reflection is found of order approximately 0.1% of the on-axis effective area at the energy of 1.49 keV. The other components are not so bright (less than 5 x 10(exp -4) times smaller than the on-axis effective area). On the other hand, we have found that the effective area of the stray light in the SXS field of view (approximately 3' x 3') at large off-axis angles (greater than 15') are approximately 1(exp -4) times smaller than the on-axis effective area (approximately 590 sq cm at 1.49 keV).
Pattern recognition invariant under changes of scale and orientation
NASA Astrophysics Data System (ADS)
Arsenault, Henri H.; Parent, Sebastien; Moisan, Sylvain
1997-08-01
We have used a modified method proposed by neiberg and Casasent to successfully classify five kinds of military vehicles. The method uses a wedge filter to achieve scale invariance, and lines in a multi-dimensional feature space correspond to each target with out-of-plane orientations over 360 degrees around a vertical axis. The images were not binarized, but were filtered in a preprocessing step to reduce aliasing. The feature vectors were normalized and orthogonalized by means of a neural network. Out-of-plane rotations of 360 degrees and scale changes of a factor of four were considered. Error-free classification was achieved.
Wide-Field-of-View Millimeter-Wave Telescope Design with Ultra-Low Cross-Polarization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernacki, Bruce E.; Kelly, James F.; Sheen, David M.
2012-05-01
As millimeter-wave arrays become available, off-axis imaging performance of the fore optics increases in importance due to the relatively large physical extent of the arrays. Typically, simple optical telescope designs are adapted to millimeter-wave imaging but single-mirror spherical or classic conic designs cannot deliver adequate image quality except near the optical axis. Since most millimeter-wave designs are quasi-optical, optical ray tracing and commercial design software can be used to optimize designs to improve off-axis imaging as well as minimize cross-polarization. Methods that obey the Dragone-Mizuguchi condition for the design of reflective millimeter-wave telescopes with low cross-polarization also provide additional degreesmore » of freedom that offer larger fields of view than possible with single-reflector designs. Dragone’s graphical design method does not lend itself readily to computer-based optical design approaches, but subsequent authors expanded on Dragone’s geometric design approach with analytic expressions that describe the location, shape, off-axis height and tilt of the telescope elements that satisfy Dragone’s design rules and can be used as a first-order design for subsequent computer-based design and optimization. We investigate two design variants that obey the Dragone-Mizuguchi conditions that exhibit ultra-low polarization crosstalk and a large diffraction-limited field of view well suited to millimeter-wave imaging arrays.« less
Simple Correction of Alar Retraction by Conchal Cartilage Extension Grafts.
Jang, Yong Jun; Kim, Sung Min; Lew, Dae Hyun; Song, Seung Yong
2016-11-01
Alar retraction is a challenging condition in rhinoplasty marked by exaggerated nostril exposure and awkwardness. Although various methods for correcting alar retraction have been introduced, none is without drawbacks. Herein, we report a simple procedure that is both effective and safe for correcting alar retraction using only conchal cartilage grafting. Between August 2007 and August 2009, 18 patients underwent conchal cartilage extension grafting to correct alar retraction. Conchal cartilage extension grafts were fixed to the caudal margins of the lateral crura and covered with vestibular skin advancement flaps. Preoperative and postoperative photographs were reviewed and analyzed. Patient satisfaction was surveyed and categorized into 4 groups (very satisfied, satisfied, moderate, or unsatisfied). According to the survey, 8 patients were very satisfied, 9 were satisfied, and 1 considered the outcome moderate, resulting in satisfaction for most patients. The average distance from the alar rim to the long axis of the nostril was reduced by 1.4 mm (3.6 to 2.2 mm). There were no complications, except in 2 cases with palpable cartilage step-off that resolved without any aesthetic problems. Conchal cartilage alar extension graft is a simple, effective method of correcting alar retraction that can be combined with aesthetic rhinoplasty conveniently, utilizing conchal cartilage, which is the most similar cartilage to alar cartilage, and requiring a lesser volume of cartilage harvest compared to previously devised methods. However, the current procedure lacks efficacy for severe alar retraction and a longer follow-up period may be required to substantiate the enduring efficacy of the current procedure.
Pressure Distributions About Finite Wedges in Bounded and Unbounded Subsonic Streams
NASA Technical Reports Server (NTRS)
Donoughe, Patrick L; Prasse, Ernst I
1953-01-01
An analytical investigation of incompressible flow about wedges was made to determine effects of tunnel-wedge ratio and wedge angle on the wedge pressure distributions. The region of applicability of infinite wedge-type velocity distribution was examined for finite wedges. Theoretical and experimental pressure coefficients for various tunnel-wedge ratios, wedge angles, and subsonic Mach numbers were compared.
Multi-species beam hardening calibration device for x-ray microtomography
NASA Astrophysics Data System (ADS)
Evershed, Anthony N. Z.; Mills, David; Davis, Graham
2012-10-01
Impact-source X-ray microtomography (XMT) is a widely-used benchtop alternative to synchrotron radiation microtomography. Since X-rays from a tube are polychromatic, however, greyscale `beam hardening' artefacts are produced by the preferential absorption of low-energy photons in the beam path. A multi-material `carousel' test piece was developed to offer a wider range of X-ray attenuations from well-characterised filters than single-material step wedges can produce practically, and optimization software was developed to produce a beam hardening correction by use of the Nelder-Mead optimization method, tuned for specimens composed of other materials (such as hydroxyapatite [HA] or barium for dental applications.) The carousel test piece produced calibration polynomials reliably and with a significantly smaller discrepancy between the calculated and measured attenuations than the calibration step wedge previously in use. An immersion tank was constructed and used to simplify multi-material samples in order to negate the beam hardening effect of low atomic number materials within the specimen when measuring mineral concentration of higher-Z regions. When scanned in water at an acceleration voltage of 90 kV a Scanco AG hydroxyapatite / poly(methyl methacrylate) calibration phantom closely approximates a single-material system, producing accurate hydroxyapatite concentration measurements. This system can then be corrected for beam hardening for the material of interest.
A cylindrical specimen holder for electron cryo-tomography.
Palmer, Colin M; Löwe, Jan
2014-02-01
The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the "missing wedge" problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Dinter, D.A.
1985-01-01
The offshore stratigraphy of the Quaternary Gubik Formation of Arctic Alaska has been studied on high-resolution seismic profiles with a maximum sub-seafloor penetration of about 100 m. In general, marine transgressive subunits of the Gubik Formation are wedge-shaped on the shelf, thickening slightly seaward to the shelf break, beyond which they are offset by landslides and slumps. Beneath the eastern third of the Alaskan Beaufort shelf, active folding has created two persistent structural depressions, the Eastern and Western Wedge Terranes, in which the wedge morphology is especially well developed. The youngest transgressive marine wedge, which was deposited in such a way as to fill these depressions, leaving a generally flat present-day shelf surface, is inferred to be late Wisconsin or younger in age because it overlies a prominent disconformity interpreted to have been formed during the late Wisconsin glacial sea-level minimum. The thickness of this youngest wedge, Unit A, locally exceeds 40 m on the outer shelf, yet apparently relict gravel deposits collected from its seabed surface indicate that the depositional rate is presently quite low on the middle and outer shelf. Lithologies of the gravels are exotic to Alaska, but similar to suites exposed in the Canadian Arctic Islands. These observations suggest a depositional scenario in which the retreating Laurentide Ice Sheet shed sediment-laden icebergs from the Canadian Arctic Islands into the Arctic Ocean following the late Wisconsin glacial maximum. These bergs were then rafted westward by the Beaufort Gyre and grounded on the Alaskan shelf by northeasterly prevailing winds. Especially large numbers of bergs accumulated in the wedge terrane embayments-created as sea level rose-and melted there, filling the embayments with their sedimentary cargo. As glacial retreat slowed, depositional rates on the shelf dwindled. This mode of deposition in the Alaskan Beaufort wedge terranes may be typical of early post-glacial transgressive phases throughout Quaternary time. It has resulted in the preservation of disconformities that apparently formed during glacioeustatic lowstands, and whose seaward termination depths, appropriately corrected, may yield estimates of lowstand magnitudes. Knowledge of global sea-level fluctuations back through the Sangamon Interglacial (oxygen isotope stage 5e) and possible correlations with dated onshore deposits have facilitated a tentative correlation of major disconformities in the Beaufort Sea record with major 18O enrichment maxima in the oxygen isotope curve back through stage 8. In this tentative scheme, close similarities between the two data sets occur both in magnitudes and in numbers of fluctuations intervening between major correlation points. Further testing of the Quaternary depositional model suggested here and of the resulting sea level curve awaits the collection and dating of core samples from the Beaufort wedge terranes. ?? 1985.
SU-F-T-261: Reconstruction of Initial Photon Fluence Based On EPID Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seliger, T; Engenhart-Cabillic, R; Czarnecki, D
2016-06-15
Purpose: Verifying an algorithm to reconstruct relative initial photon fluence for clinical use. Clinical EPID and CT images were acquired to reconstruct an external photon radiation treatment field. The reconstructed initial photon fluence could be used to verify the treatment or calculate the applied dose to the patient. Methods: The acquired EPID images were corrected for scatter caused by the patient and the EPID with an iterative reconstruction algorithm. The transmitted photon fluence behind the patient was calculated subsequently. Based on the transmitted fluence the initial photon fluence was calculated using a back-projection algorithm which takes the patient geometry andmore » its energy dependent linear attenuation into account. This attenuation was gained from the acquired cone-beam CT or the planning CT by calculating a water-equivalent radiological thickness for each irradiation direction. To verify the algorithm an inhomogeneous phantom consisting of three inhomogeneities was irradiated by a static 6 MV photon field and compared to a reference flood field image. Results: The mean deviation between the reconstructed relative photon fluence for the inhomogeneous phantom and the flood field EPID image was 3% rising up to 7% for off-axis fluence. This was probably caused by the used clinical EPID calibration, which flattens the inhomogeneous fluence profile of the beam. Conclusion: In this clinical experiment the algorithm achieved good results in the center of the field while it showed high deviation of the lateral fluence. This could be reduced by optimizing the EPID calibration, considering the off-axis differential energy response. In further progress this and other aspects of the EPID, eg. field size dependency, CT and dose calibration have to be studied to realize a clinical acceptable accuracy of 2%.« less
NASA Astrophysics Data System (ADS)
Shields, S.; Petronis, M. S.; Pluhar, C. J.; Gordon, L.
2014-12-01
The mid-Miocene Jack Springs Tuff (JST) outcrops across the western Mina Deflection accommodation zone, west-central Nevada and into eastern California. Previously, the source location for the JST was unknown, yet recent studies northwest of Mono Lake, CA have identified a relatively un-rotated structural block in which to reference the paleomagnetic data. Although new studies have indicated that this block may be rotated up to 13º, we argue that the probable source area is located near the Bodie Hills, CA. At this site, the paleomagnetic reference direction is D = 353°, I = 43°, α95 = 7.7° (Carlson et al, 2013). Based on these data, the JST can be used to measure absolute vertical-axis rotation as well as enable reconstruction of the paleo-topography using the corrected anisotropy of magnetic susceptibility (AMS) data. A total of 19 sites were sampled to constrain Cenozoic to recent vertical axis rotation within the region and AMS experiments were conducted to determine the flow direction of the JST. Curie point estimates indicate that the JST ranges in titanium concentration from 0.042 to 1.10, indicating a low to moderate titanomagnetite phase (Akimoto, 1962). Demagnetization experiments reveal mean destructive fields of the NRM ranging between 15mT and 40mT suggesting that both multi-domain to pseudo-single domain grains are the dominant ferromagnetic phases that carry the remanence and AMS fabric. Preliminary paleomagnetic data yield stable single component demagnetization behavior for most sites that, after structural correction, indicate clockwise vertical axis rotation ranging from +20°± 10° to +60°± 11° between multiple fault blocks. The uncorrected AMS data yield oblate magnetic fabrics that can be used to infer the transport direction, source region, and paleovalley geometry of the JST. These data are tentatively interpreted to indicate west to east transport of the JST across the Mono Basin region into the Mina Deflection that was erupted and flowed into a paleovalley off the Sierra Nevada Mountain front. Based on the new paleomagnetic data, we hypothesize that the JST experienced clockwise vertical axis rotation associated with transtensional faulting east of Mono Lake, CA. Our paleomagnetic data support this hypothesis and we argue that deformation likely occurred between ca. 9.5 Ma to as late as 3 Ma.
NASA Astrophysics Data System (ADS)
Godin, E.; Fortier, D.
2010-12-01
Glaciers flowing from local ice-cap in the Canadian High-Arctic often feed fluvio-glacial outwashes flowing toward the sea. These fluvio-glacial outwashes are often bordered by terraces in which ice-wedge polygons developed during the Holocene (Fortier et al. 2004). In the valley of glacier C-79 on Bylot Island, Nunavut (N 73° 09’ - W 79° 57’) these ice-wedge polygons were recently destabilized very rapidly by processes of thermo-erosion related to surface run-off. Thirty-five such gullies were identified, mapped by remote sensing, characterized and georeferenced in detail during field surveys in 2009-2010. The objectives of this paper are to: 1) quantify the area and shape of gully systems in the valley of glacier C-79 in relation with its depositional environment and 2) evaluate the impact of gully development on the local hydrography in the valley. Degradation of permafrost by thermo-erosion processes is very active in the valley C-79. It covered in 2010 an area of approximately 152000 m2, the average gully length was 542 m with a maximum of 3520 m. Thermo-erosion gullies induced by snowmelt runoff water were formed in 3 distinct depositional environments within the valley: 1) in aeolian, organic-poor deposits near the pro-glacial river outwash, 2) in organic-rich, humid, ice-wedges polygon terraces, and 3) in colluviums close to the valley walls. Thermo-erosion of ice wedge polygons resulted in typical landforms such as: sinkholes and tunnels, gully channels with alluvial levees, retrogressive thaw-slump, active layer detachment slide and baydjarakhs (Godin and Fortier, in press). Positive feedback effects, especially at the gully head and around sinkholes, sustain processes of thermo-erosion and enhance permafrost degradation. Thermo-erosion processes and associated heat transfers combined with the effects of gullying significantly affected ice-wedges polygons terraces. The formation of gullies created permanent changes in the landscape and in the hydrographic network such as the total or partial destruction of polygons, drainage of adjacent wetlands and the birth of new drainage systems (Fortier et al. 2007). The hydrographic network layout is affected by newly formed gullies, streams running on the terrace being diverted from their beds toward gully systems. A stabilized gully where thermo-erosion is no more active will continue to drain the terrace and thus these processes causes irreversible changes to the geomorphic configuration of ice wedge polygon terraces. Fortier, D., Allard, M., Shur, Y. 2007. Observation of Rapid Drainage System Development by Thermal Erosion of Ice Wedges on Bylot Island, Canadian Arctic Archipelago. Permafrost and Periglacial Processes, 18: 229-243. Fortier, D., Allard, M. 2004. Late Holocene Syngenetic Ice-wedge Polygons Development, Bylot Island, Canadian Arctic Archipelago. Canadian Journal of Earth Sciences, 41: 997-1012. Godin, E., Fortier, D. (in press) Geomorphology of thermo-erosion gullies - case study from Bylot Island, Nunavut, Canada. Proceedings 6th Canadian Permafrost Conference and 63rd Canadian Geotechnical Conference, Calgary, October 2010.
Intensity inhomogeneity correction of SD-OCT data using macular flatspace.
Lang, Andrew; Carass, Aaron; Jedynak, Bruno M; Solomon, Sharon D; Calabresi, Peter A; Prince, Jerry L
2018-01-01
Images of the retina acquired using optical coherence tomography (OCT) often suffer from intensity inhomogeneity problems that degrade both the quality of the images and the performance of automated algorithms utilized to measure structural changes. This intensity variation has many causes, including off-axis acquisition, signal attenuation, multi-frame averaging, and vignetting, making it difficult to correct the data in a fundamental way. This paper presents a method for inhomogeneity correction by acting to reduce the variability of intensities within each layer. In particular, the N3 algorithm, which is popular in neuroimage analysis, is adapted to work for OCT data. N3 works by sharpening the intensity histogram, which reduces the variation of intensities within different classes. To apply it here, the data are first converted to a standardized space called macular flat space (MFS). MFS allows the intensities within each layer to be more easily normalized by removing the natural curvature of the retina. N3 is then run on the MFS data using a modified smoothing model, which improves the efficiency of the original algorithm. We show that our method more accurately corrects gain fields on synthetic OCT data when compared to running N3 on non-flattened data. It also reduces the overall variability of the intensities within each layer, without sacrificing contrast between layers, and improves the performance of registration between OCT images. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corsi, Alessandra; Gal-Yam, A.; Kulkarni, S. R.
Long duration γ-ray bursts are a rare subclass of stripped-envelope core-collapse supernovae (SNe) that launch collimated relativistic outflows (jets). All γ-ray-burst-associated SNe are spectroscopically Type Ic, with broad-lines, but the fraction of broad-lined SNe Ic harboring low-luminosity γ-ray bursts remains largely unconstrained. Some SNe should be accompanied by off-axis γ-ray burst jets that initially remain invisible, but then emerge as strong radio sources (as the jets decelerate). However, this critical prediction of the jet model for γ-ray bursts has yet to be verified observationally. Here, we present K. G. Jansky Very Large Array observations of 15 broad-lined SNe of Type Ic discovered by the Palomar Transient Factory in an untargeted manner. Most of the SNe in our sample exclude radio emission observationally similar to that of the radio-loud, relativistic SN 1998bw. We constrain the fraction of 1998bw-like broad-lined SNe Ic to bemore » $$\\lesssim 41 \\% $$ (99.865% confidence). Most of the events in our sample also exclude off-axis jets similar to GRB 031203 and GRB 030329, but we cannot rule out off-axis γ-ray bursts expanding in a low-density wind environment. Three SNe in our sample are detected in the radio. PTF11qcj and PTF14dby show late-time radio emission with average ejecta speeds of ≈0.3–0.4 c, on the dividing line between relativistic and "ordinary" SNe. The speed of PTF11cmh radio ejecta is poorly constrained. We estimate that $$\\lesssim 85 \\% $$ (99.865% confidence) of the broad-lined SNe Ic in our sample may harbor off-axis γ-ray bursts expanding in media with densities in the range probed by this study.« less
Modeling free energy availability from Hadean hydrothermal systems to the first metabolism.
Simoncini, E; Russell, M J; Kleidon, A
2011-12-01
Off-axis Hydrothermal Systems (HSs) are seen as the possible setting for the emergence of life. As the availability of free energy is a general requirement to drive any form of metabolism, we ask here under which conditions free energy generation by geologic processes is greatest and relate these to the conditions found at off-axis HSs. To do so, we present a conceptual model in which we explicitly capture the energetics of fluid motion and its interaction with exothermic reactions to maintain a state of chemical disequilibrium. Central to the interaction is the temperature at which the exothermic reactions take place. This temperature not only sets the equilibrium constant of the chemical reactions and thereby the distance of the actual state to chemical equilibrium, but these reactions also shape the temperature gradient that drives convection and thereby the advection of reactants to the reaction sites and the removal of the products that relate to geochemical free energy generation. What this conceptual model shows is that the positive feedback between convection and the chemical kinetics that is found at HSs favors a greater rate of free energy generation than in the absence of convection. Because of the lower temperatures and because the temperature of reactions is determined more strongly by these dynamics rather than an external heat flux, the conditions found at off-axis HSs should result in the greatest rates of geochemical free energy generation. Hence, we hypothesize from these thermodynamic considerations that off-axis HSs seem most conducive for the emergence of protometabolic pathways as these provide the greatest, abiotic generation rates of chemical free energy.
Toda, Y; Segal, N; Kato, A; Yamamoto, S; Irie, M
2001-12-01
To assess the efficacy of a lateral wedge insole with elastic strapping of the subtalar joint for conservative treatment of osteoarthritis (OA) of the knee. The efficacy of a novel insole with elastic subtalar strapping and a traditional shoe insert wedge insole was compared. Ninety female outpatients with OA of the knee were treated with wedge insoles for 8 weeks. Randomization was performed according to birth date. Standing radiographs with unilateral insole use were used to analyze the femorotibial and talar tilt angles for each patient with and without their respective insole. Visual analog scale (VAS) score for subjective knee pain at the final assessment was compared with that at baseline in both groups. Participants wearing the elastically strapped insole (n = 46) had significantly decreased femorotibial angle (p < 0.0001) and talar tilt angle (p = 0.005) and significantly improved VAS pain score (p = 0.045) in comparison with baseline assessments. These significant differences were not found in the group with the inserted insole (n = 44). The novel strapped insole leads to valgus angulation of the talus, resulting in correction of the femorotibial angle in patients with knee OA with varus deformity, and may have a therapeutic effect similar to that of high tibial osteotomy.
THE ABSOLUTE RATE OF LGRB FORMATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, J. F.; Schady, P.
2016-06-01
We estimate the long-duration gamma-ray burst (LGRB) progenitor rate using our recent work on the effects of environmental metallically on LGRB formation in concert with supernovae (SNe) statistics via an approach patterned loosely off the Drake equation. Beginning with the cosmic star formation history, we consider the expected number of broad-line Type Ic events (the SNe type associated with LGRBs) that are in low-metallicity host environments adjusted by the contribution of high-metallicity host environments at a much reduced rate. We then compare this estimate to the observed LGRB rate corrected for instrumental selection effects to provide a combined estimate ofmore » the efficiency fraction of these progenitors to produce LGRBs and the fraction of which are beamed in our direction. From this we estimate that an aligned LGRB occurs for approximately every 4000 ± 2000 low-metallically broad-lined SNe Ic. Therefore, if one assumes a semi-nominal beaming factor of 100, then only about one such supernova out of 40 produce an LGRB. Finally, we propose an off-axis LGRB search strategy of targeting only broad-line Type Ic events that occur in low-metallicity hosts for radio observation.« less
The Absolute Rate of LGRB Formation
NASA Astrophysics Data System (ADS)
Graham, J. F.; Schady, P.
2016-06-01
We estimate the long-duration gamma-ray burst (LGRB) progenitor rate using our recent work on the effects of environmental metallically on LGRB formation in concert with supernovae (SNe) statistics via an approach patterned loosely off the Drake equation. Beginning with the cosmic star formation history, we consider the expected number of broad-line Type Ic events (the SNe type associated with LGRBs) that are in low-metallicity host environments adjusted by the contribution of high-metallicity host environments at a much reduced rate. We then compare this estimate to the observed LGRB rate corrected for instrumental selection effects to provide a combined estimate of the efficiency fraction of these progenitors to produce LGRBs and the fraction of which are beamed in our direction. From this we estimate that an aligned LGRB occurs for approximately every 4000 ± 2000 low-metallically broad-lined SNe Ic. Therefore, if one assumes a semi-nominal beaming factor of 100, then only about one such supernova out of 40 produce an LGRB. Finally, we propose an off-axis LGRB search strategy of targeting only broad-line Type Ic events that occur in low-metallicity hosts for radio observation.
NASA Astrophysics Data System (ADS)
Marsolat, F.; De Marzi, L.; Pouzoulet, F.; Mazal, A.
2016-01-01
In proton therapy, the relative biological effectiveness (RBE) depends on various types of parameters such as linear energy transfer (LET). An analytical model for LET calculation exists (Wilkens’ model), but secondary particles are not included in this model. In the present study, we propose a correction factor, L sec, for Wilkens’ model in order to take into account the LET contributions of certain secondary particles. This study includes secondary protons and deuterons, since the effects of these two types of particles can be described by the same RBE-LET relationship. L sec was evaluated by Monte Carlo (MC) simulations using the GATE/GEANT4 platform and was defined by the ratio of the LET d distributions of all protons and deuterons and only primary protons. This method was applied to the innovative Pencil Beam Scanning (PBS) delivery systems and L sec was evaluated along the beam axis. This correction factor indicates the high contribution of secondary particles in the entrance region, with L sec values higher than 1.6 for a 220 MeV clinical pencil beam. MC simulations showed the impact of pencil beam parameters, such as mean initial energy, spot size, and depth in water, on L sec. The variation of L sec with these different parameters was integrated in a polynomial function of the L sec factor in order to obtain a model universally applicable to all PBS delivery systems. The validity of this correction factor applied to Wilkens’ model was verified along the beam axis of various pencil beams in comparison with MC simulations. A good agreement was obtained between the corrected analytical model and the MC calculations, with mean-LET deviations along the beam axis less than 0.05 keV μm-1. These results demonstrate the efficacy of our new correction of the existing LET model in order to take into account secondary protons and deuterons along the pencil beam axis.
Deep-level dominated electrical characteristics of Au contacts on beta-SiC
NASA Technical Reports Server (NTRS)
Das, K.; Kong, H. S.; Petit, J. B.; Bumgarner, J. W.; Davis, R. F.; Matus, L. G.
1990-01-01
Electrical characteristics of Au contacts on beta-SiC films, grown epitaxially on both nominal and off-axis (100) silicon substrates, are reported. An analysis of the logarithmic I-V plots of the Au/beta-SiC diodes revealed information pertaining to the deep states present in the materials. It was found that while the beta-SiC films grown on nominally (100) oriented substrates show the presence of two deep levels located between 0.26 and 0.38 eV below the conduction bandedge, the beta-SiC films deposited on off-axis substrates have only one deep level, located about 0.49 eV below the conduction bandedge for the 2-deg off (100) substrates and 0.57 eV for the 4-deg off (100) substrates. The presence of the shallower deep states in the beta-SiC films grown on nominal (100) substrates is attributed to the electrical activity of antiphase domain boundaries.
Four-mirror extreme ultraviolet (EUV) lithography projection system
Cohen, Simon J; Jeong, Hwan J; Shafer, David R
2000-01-01
The invention is directed to a four-mirror catoptric projection system for extreme ultraviolet (EUV) lithography to transfer a pattern from a reflective reticle to a wafer substrate. In order along the light path followed by light from the reticle to the wafer substrate, the system includes a dominantly hyperbolic convex mirror, a dominantly elliptical concave mirror, spherical convex mirror, and spherical concave mirror. The reticle and wafer substrate are positioned along the system's optical axis on opposite sides of the mirrors. The hyperbolic and elliptical mirrors are positioned on the same side of the system's optical axis as the reticle, and are relatively large in diameter as they are positioned on the high magnification side of the system. The hyperbolic and elliptical mirrors are relatively far off the optical axis and hence they have significant aspherical components in their curvatures. The convex spherical mirror is positioned on the optical axis, and has a substantially or perfectly spherical shape. The spherical concave mirror is positioned substantially on the opposite side of the optical axis from the hyperbolic and elliptical mirrors. Because it is positioned off-axis to a degree, the spherical concave mirror has some asphericity to counter aberrations. The spherical concave mirror forms a relatively large, uniform field on the wafer substrate. The mirrors can be tilted or decentered slightly to achieve further increase in the field size.
Goldbaum, Michael H; Jang, Gil-Jin; Bowd, Chris; Hao, Jiucang; Zangwill, Linda M; Liebmann, Jeffrey; Girkin, Christopher; Jung, Tzyy-Ping; Weinreb, Robert N; Sample, Pamela A
2009-12-01
To determine if the patterns uncovered with variational Bayesian-independent component analysis-mixture model (VIM) applied to a large set of normal and glaucomatous fields obtained with the Swedish Interactive Thresholding Algorithm (SITA) are distinct, recognizable, and useful for modeling the severity of the field loss. SITA fields were obtained with the Humphrey Visual Field Analyzer (Carl Zeiss Meditec, Inc, Dublin, California) on 1,146 normal eyes and 939 glaucoma eyes from subjects followed by the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. VIM modifies independent component analysis (ICA) to develop separate sets of ICA axes in the cluster of normal fields and the 2 clusters of abnormal fields. Of 360 models, the model with the best separation of normal and glaucomatous fields was chosen for creating the maximally independent axes. Grayscale displays of fields generated by VIM on each axis were compared. SITA fields most closely associated with each axis and displayed in grayscale were evaluated for consistency of pattern at all severities. The best VIM model had 3 clusters. Cluster 1 (1,193) was mostly normal (1,089, 95% specificity) and had 2 axes. Cluster 2 (596) contained mildly abnormal fields (513) and 2 axes; cluster 3 (323) held mostly moderately to severely abnormal fields (322) and 5 axes. Sensitivity for clusters 2 and 3 combined was 88.9%. The VIM-generated field patterns differed from each other and resembled glaucomatous defects (eg, nasal step, arcuate, temporal wedge). SITA fields assigned to an axis resembled each other and the VIM-generated patterns for that axis. Pattern severity increased in the positive direction of each axis by expansion or deepening of the axis pattern. VIM worked well on SITA fields, separating them into distinctly different yet recognizable patterns of glaucomatous field defects. The axis and pattern properties make VIM a good candidate as a preliminary process for detecting progression.
NASA Astrophysics Data System (ADS)
Demasi, Alexander; Erdem, Gozde; Chinta, Priya; Headrick, Randall; Ludwig, Karl
2012-02-01
The fundamental kinetics of thin film growth remains an active area of investigation. In this study, silicon thin films were grown at room temperature on silicon substrates via both on-axis and off-axis plasma sputter deposition, while the evolution of surface morphology was measured in real time with in-situ grazing incidence small angle x-ray scattering (GISAXS) at the National Synchrotron Light Source. GISAXS is a surface-sensitive, non-destructive technique, and is therefore ideally suited to a study of this nature. In addition to investigating the effect of on-axis versus off-axis bombardment, the effect of sputter gas partial pressure was examined. Post-facto, ex-situ atomic force microscopy (AFM) was used to measure the final surface morphology of the films, which could subsequently be compared with the surface morphology determined by GISAXS. Comparisons are made between the observed surface evolution during growth and theoretical predictions. This work was supported by the Department of Energy, Office of Basic Energy Sciences.
Gimbaled multispectral imaging system and method
Brown, Kevin H.; Crollett, Seferino; Henson, Tammy D.; Napier, Matthew; Stromberg, Peter G.
2016-01-26
A gimbaled multispectral imaging system and method is described herein. In an general embodiment, the gimbaled multispectral imaging system has a cross support that defines a first gimbal axis and a second gimbal axis, wherein the cross support is rotatable about the first gimbal axis. The gimbaled multispectral imaging system comprises a telescope that fixed to an upper end of the cross support, such that rotation of the cross support about the first gimbal axis causes the tilt of the telescope to alter. The gimbaled multispectral imaging system includes optics that facilitate on-gimbal detection of visible light and off-gimbal detection of infrared light.
A study of rotor and platform design trade-offs for large-scale floating vertical axis wind turbines
NASA Astrophysics Data System (ADS)
Griffith, D. Todd; Paquette, Joshua; Barone, Matthew; Goupee, Andrew J.; Fowler, Matthew J.; Bull, Diana; Owens, Brian
2016-09-01
Vertical axis wind turbines are receiving significant attention for offshore siting. In general, offshore wind offers proximity to large populations centers, a vast & more consistent wind resource, and a scale-up opportunity, to name a few beneficial characteristics. On the other hand, offshore wind suffers from high levelized cost of energy (LCOE) and in particular high balance of system (BoS) costs owing to accessibility challenges and limited project experience. To address these challenges associated with offshore wind, Sandia National Laboratories is researching large-scale (MW class) offshore floating vertical axis wind turbines (VAWTs). The motivation for this work is that floating VAWTs are a potential transformative technology solution to reduce offshore wind LCOE in deep-water locations. This paper explores performance and cost trade-offs within the design space for floating VAWTs between the configurations for the rotor and platform.
APS-U LATTICE DESIGN FOR OFF-AXIS ACCUMULATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Yipeng; Borland, M.; Lindberg, R.
2017-06-25
A 67-pm hybrid-seven-bend achromat (H7BA) lattice is being proposed for a future Advanced Photon Source (APS) multi-bend-achromat (MBA) upgrade project. This lattice design pushes for smaller emittance and requires use of a swap-out (on-axis) injection scheme due to limited dynamic acceptance. Alternate lattice design work has also been performed for the APS upgrade to achieve better beam dynamics performance than the nominal APS MBA lattice, in order to allow off-axis accumulation. Two such alternate H7BA lattice designs, which target a still-low emittance of 90 pm, are discussed in detail in this paper. Although the single-particle-dynamics performance is good, simulations ofmore » collective effects indicate that surprising difficulty would be expected accumulating high single-bunch charge in this lattice. The brightness of the 90-pm lattice is also a factor of two lower than the 67-pm H7BA lattice.« less