Dang, Pragya; Singh, Sarabjeet; Saini, Sanjay; Shepard, Jo-Anne O.
2009-01-01
Objective To assess effects of off-centering, automatic exposure control, and padding on attenuation values, noise, and radiation dose when using in-plane bismuth-based shields for CT scanning. Materials and Methods A 30 cm anthropomorphic chest phantom was scanned on a 64-multidetector CT, with the center of the phantom aligned to the gantry isocenter. Scanning was repeated after placing a bismuth breast shield on the anterior surface with no gap and with 1, 2, and 6 cm of padding between the shield and the phantom surface. The "shielded" phantom was also scanned with combined modulation and off-centering of the phantom at 2 cm, 4 cm and 6 cm below the gantry isocenter. CT numbers, noise, and surface radiation dose were measured. The data were analyzed using an analysis of variance. Results The in-plane shield was not associated with any significant increment for the surface dose or CT dose index volume, which was achieved by comparing the radiation dose measured by combined modulation technique to the fixed mAs (p > 0.05). Irrespective of the gap or the surface CT numbers, surface noise increased to a larger extent compared to Hounsfield unit (HU) (0-6 cm, 26-55%) and noise (0-6 cm, 30-40%) in the center. With off-centering, in-plane shielding devices are associated with less dose savings, although dose reduction was still higher than in the absence of shielding (0 cm off-center, 90% dose reduction; 2 cm, 61%) (p < 0.0001). Streak artifacts were noted at 0 cm and 1 cm gaps but not at 2 cm and 6 cm gaps of shielding to the surface distances. Conclusion In-plane shields are associated with greater image noise, artifactually increased attenuation values, and streak artifacts. However, shields reduce radiation dose regardless of the extent of off-centering. Automatic exposure control did not increase radiation dose when using a shield. PMID:19270862
Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K
2017-08-01
To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p < 0.01). Variation in point doses between fixed-mA and AEC protocols were statistically significant across all organs at all Table positions (p < 0.001). There was up to 5-6% decrease in point doses with upward off-centering and in downward off-centering. There were statistical significant differences in point doses from dosimeters and dose-tracking software (mean difference for internal organs, 5-36% for fixed-mA & 7-48% for AEC protocols; p < 0.001; mean difference for surface organs, >92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Gudjonsdottir, J; Svensson, J R; Campling, S; Brennan, P C; Jonsdottir, B
2009-11-01
Image quality and radiation dose to the patient are important factors in computed tomography (CT). To provide constant image quality, tube current modulation (TCM) performed by automatic exposure control (AEC) adjusts the tube current to the patient's size and shape. To evaluate the effects of patient centering on tube current-time product (mAs) and image noise. An oval-shaped acrylic phantom was scanned in various off-center positions, at 30-mm intervals within a 500-mm field of view, using three different CT scanners. Acquisition parameters were similar to routine abdomen examinations at each site. The mAs was recorded and noise measured in the images. The correlation of mAs and noise with position was calculated using Pearson correlation. In all three scanners, the mAs delivered by the AEC changed with y-position of the phantom (P<0.001), with correlation values of 0.98 for scanners A and B and -0.98 for scanner C. With x-position, mAs changes were 4.9% or less. As the phantom moved into the y-positions, compared with the iso-center, the mAs varied by up to +70%, -34%, and +56% in scanners A, B, and C, respectively. For scanners A and B, noise in two regions of interest in the lower part of the phantom decreased with elevation, with correlation factors from -0.95 to -0.86 (P<0.02). In the x-direction, significant noise relationships (P<0.005) were only seen in scanner A. This study demonstrates that patient centering markedly affects the efficacy of AEC function and that tube current changes vary between scanners. Tube position when acquiring the scout projection radiograph is decisive for the direction of the mAs change. Off-center patient positions cause errors in tube current modulation that can outweigh the dose reduction gained by AEC use, and image quality is affected.
Automatic brightness control of laser spot vision inspection system
NASA Astrophysics Data System (ADS)
Han, Yang; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin
2009-10-01
The laser spot detection system aims to locate the center of the laser spot after long-distance transmission. The accuracy of positioning laser spot center depends very much on the system's ability to control brightness. In this paper, an automatic brightness control system with high-performance is designed using the device of FPGA. The brightness is controlled by combination of auto aperture (video driver) and adaptive exposure algorithm, and clear images with proper exposure are obtained under different conditions of illumination. Automatic brightness control system creates favorable conditions for positioning of the laser spot center later, and experiment results illuminate the measurement accuracy of the system has been effectively guaranteed. The average error of the spot center is within 0.5mm.
Automatic exposure control for space sequential camera
NASA Technical Reports Server (NTRS)
Mcatee, G. E., Jr.; Stoap, L. J.; Solheim, C. D.; Sharpsteen, J. T.
1975-01-01
The final report for the automatic exposure control study for space sequential cameras, for the NASA Johnson Space Center is presented. The material is shown in the same sequence that the work was performed. The purpose of the automatic exposure control is to automatically control the lens iris as well as the camera shutter so that the subject is properly exposed on the film. A study of design approaches is presented. Analysis of the light range of the spectrum covered indicates that the practical range would be from approximately 20 to 6,000 foot-lamberts, or about nine f-stops. Observation of film available from space flights shows that optimum scene illumination is apparently not present in vehicle interior photography as well as in vehicle-to-vehicle situations. The evaluation test procedure for a breadboard, and the results, which provided information for the design of a brassboard are given.
Coronagraphic Observations of the Lunar Sodium Exosphere
NASA Astrophysics Data System (ADS)
Killen, R. M.; Johnson, J. D.; Morgan, T. H.; Potter, A. E.
2017-12-01
We have designed, built and installed a small robotic coronagraph at the Winer Observatory in Sonoita, Arizona, in order to observe the sodium exosphere out to one-half degree around the Moon. Observations are obtained remotely every available clear night from our home base at Goddard Space Flight Center. Our data encompass lunations in 2015, 2016, and 2017, thus we have a long baseline of sodium exospheric calibrated images. We employ an Andover temperature-controlled 1.5 Å wide narrow-band filter centered on the sodium D2 line, and a similar 1.5 Å filter centered blueward of the D2 line by 5 Å. Exposures of 10 minutes are required to image the sodium corona at good signal to noise. Autoguiding is performed locking onto a small bright crater each night. Following each onband-offband exposure pair, on- and off-band images of the lunar surface are collected by taking a 0.1- 0.5 second exposures with the open filter. The sodium is calibrated using the counts in the open Moon images and the Hapke function. We use both dark and bright Hapke parameters for comparison check using Mare and highlands, respectively. In order to obtain the sodium profile around the entire limb, the images are transformed using a polar transform and the profiles are extracted automatically. We have derived zenith column abundances and surface abundances around the lunar limb for each observation and we fit these observations with a 3-dimensional model. We compare our lunar model derived from these observations with the data from the spectrograph onboard the LADEE spacecraft.
An accurate laser radiometer for determining visible exposure times.
Royston, D D
1985-01-01
A laser light radiometer has been developed for the Electro-Optics Branch of the Center for Devices and Radiological Health (CDRH). The radiometer measures direct laser radiation emitted in the visible spectrum. Based upon this measurement, the instrument's microprocessor automatically determines at what time duration the exposure to the measured laser radiation would exceed either the class I accessible emission limits of the Federal Performance Standard for laser products or the maximum permissible exposure limits of laser user safety standards. The instrument also features automatic background level compensation, pulse measurement capability, and self-diagnosis. Measurement of forward surface illumination levels preceding HpD photoradiation therapy is possible.
User Guide for the Anvil Threat Cooridor Forecast Tool V2.4 for AWIPS
NASA Technical Reports Server (NTRS)
Barett, Joe H., III; Bauman, William H., III
2008-01-01
The Anvil Tool GUI allows users to select a Data Type, toggle the map refresh on/off, place labels, and choose the Profiler Type (source of the KSC 50 MHz profiler data), the Date- Time of the data, the Center of Plot, and the Station (location of the RAOB or 50 MHz profiler). If the Data Type is Models, the user selects a Fcst Hour (forecast hour) instead of Station. There are menus for User Profiles, Circle Label Options, and Frame Label Options. Labels can be placed near the center circle of the plot and/or at a specified distance and direction from the center of the circle (Center of Plot). The default selection for the map refresh is "ON". When the user creates a new Anvil Tool map with Refresh Map "ON, the plot is automatically displayed in the AWIPS frame. If another Anvil Tool map is already displayed and the user does not change the existing map number shown at the bottom of the GUI, the new Anvil Tool map will overwrite the old one. If the user turns the Refresh Map "OFF", the new Anvil Tool map is created but not automatically displayed. The user can still display the Anvil Tool map through the Maps dropdown menu* as shown in Figure 4.
Remote Observations of the Lunar Sodium Corona
NASA Astrophysics Data System (ADS)
Killen, Rosemary M.; Morgan, Thomas H.; Potter, Andrew; SSERVI DREAM2
2017-10-01
We have designed, built and installed a small robotic coronagraph at the Winer Observatory in Sonoita, Arizona, in order to observe the sodium exosphere out to one-half degree around the Moon. Observations are obtained remotely every available clear night from our home base at Goddard Space Flight Center. Our data encompass lunations in 2015, 2016, and 2017, thus we have a long baseline of sodium exospheric calibrated images. We employ an Andover temperature-controlled 1.5 Å wide narrow-band filter centered on the sodium D2 line, and a similar 1.5 Å filter centered blueward of the D2 line by 5 Å. Exposures of 10 minutes are required to image the sodium corona at good signal to noise. Autoguiding is performed locking onto a small bright crater each night. Following each onband-offband exposure pair, on- and off-band images of the lunar surface are collected by taking a 0.1- 0.5 second exposures with the open filter. The sodium is calibrated using the counts in the open Moon images and the Hapke function. We use both dark and bright Hapke parameters for comparison check using Mare and highlands, respectively. In order to obtain the sodium profile around the entire limb, the images are transformed using a polar transform and the profiles are extracted automatically. Example of our resulting images of the sodium corona will be shown, with the image of the moon's disk (taken subsequently to the occulted coronal image) superimposed on the occulting disk, thus showing the position and phase of the moon under the disk. We compare our lunar model derived from these observations with the data from the UV spectrograph onboard the LADEE spacecraft.
2008-02-01
drain with collector • Final pressure switch with gauge and automatic shut- off • (2) Hour meter • Oil filled finel pressure gauge 0~400bar/5800psi...Automatic condensate drain system Final pressure switch with gauge and automatic shut-off (2) Hour meter, (2) On/Off Switch Filling Connection Four
NASA Technical Reports Server (NTRS)
Coogan, J. J.
1986-01-01
Modifications were designed for the B-737-100 Research Aircraft autobrake system hardware of the Advanced Transport Operating Systems (ATOPS) Program at Langley Research Center. These modifications will allow the on-board flight control computer to control the aircraft deceleration after landing to a continuously variable level for the purpose of executing automatic high speed turn-offs from the runway. A bread board version of the proposed modifications was built and tested in simulated stopping conditions. Test results, for various aircraft weights, turnoff speed, winds, and runway conditions show that the turnoff speeds are achieved generally with errors less than 1 ft/sec.
BIOLOGICAL IRRADIATION FACILITY
McCorkle, W.H.; Cern, H.S.
1962-04-24
A facility for irradiating biological specimens with neutrons is described. It includes a reactor wherein the core is off center in a reflector. A high-exposure room is located outside the reactor on the side nearest the core while a low-exposure room is located on the opposite side. Means for converting thermal neutrons to fast neutrons are movably disposed between the reactor core and the high and low-exposure rooms. (AEC)
Bloem, B R; Beckley, D J; van Dijk, J G; Zwinderman, A H; Remler, M P; Roos, R A
1996-09-01
It is still unclear why balance impairment in Parkinson's disease (PD) often responds insufficiently to dopaminergic medication. We have studied this issue in 23 patients with idiopathic PD and 24 healthy controls. Our specific purposes were (a) to investigate the contribution of abnormal automatic postural responses to balance impairment in PD and (b) to assess the influence of dopaminergic medication on abnormal automatic postural responses and balance impairment. Standing subjects received 4 degrees "toe-up" rotational perturbations of a supporting forceplate. We bilaterally recorded posturally destabilizing medium latency (ML) responses from the stretched gastrocnemius muscles and functionally corrective long latency (LL) responses from the shortened tibialis anterior (TA) muscles. We also assessed changes in the center of foot pressure (CFP) and the center of gravity (COG). All patients were tested in the "off" and "on" phases. All controls were tested and retested after 1 h. During the off phase, we found enlarged ML amplitudes and diminished LL amplitudes in patients, together with a markedly increased posterior displacement of the COG. The abnormal ML and LL responses were partially responsible for the increased body sway in patients because the initial forward (destabilizing) displacement of the CFP was increased, while the subsequent backward displacement of the CFP (a measure of the corrective braking action of LL responses) was delayed. Abnormal late automatic or possibly more voluntary postural corrections also contributed substantially to the increased body sway. During the on phase, ML amplitudes were reduced in patients but remained increased compared with controls. LL amplitudes no longer differed between both groups due to a modest, possibly dopamine-related increase in patients and a simultaneous decrease in controls. The abnormal CFP displacement was only partially improved by dopaminergic medication. The later postural corrections were not improved at all. Consequently, the increased posterior COG displacement was not ameliorated during the on phase. We conclude that (a) a combination of abnormal automatic and perhaps more voluntary postural corrections contributes to increased body sway in PD and (b) dopaminergic medication fails to improve balance impairment in PD because early automatic postural responses are only partially corrected, while later occurring postural corrections are not improved at all. These electrophysiological results support clinical observations and suggest that nondopaminergic lesions play a significant role in the pathophysiology of postural abnormalities in PD.
46 CFR 58.05-10 - Automatic shut-off.
Code of Federal Regulations, 2010 CFR
2010-10-01
... AND RELATED SYSTEMS Main Propulsion Machinery § 58.05-10 Automatic shut-off. Main propulsion machinery... controls must shut down main propulsion machinery in case of a failure, such as failure of the lubricating...
46 CFR 58.05-10 - Automatic shut-off.
Code of Federal Regulations, 2011 CFR
2011-10-01
... AND RELATED SYSTEMS Main Propulsion Machinery § 58.05-10 Automatic shut-off. Main propulsion machinery... controls must shut down main propulsion machinery in case of a failure, such as failure of the lubricating...
46 CFR 58.05-10 - Automatic shut-off.
Code of Federal Regulations, 2014 CFR
2014-10-01
... AND RELATED SYSTEMS Main Propulsion Machinery § 58.05-10 Automatic shut-off. Main propulsion machinery... controls must shut down main propulsion machinery in case of a failure, such as failure of the lubricating...
46 CFR 58.05-10 - Automatic shut-off.
Code of Federal Regulations, 2012 CFR
2012-10-01
... AND RELATED SYSTEMS Main Propulsion Machinery § 58.05-10 Automatic shut-off. Main propulsion machinery... controls must shut down main propulsion machinery in case of a failure, such as failure of the lubricating...
46 CFR 58.05-10 - Automatic shut-off.
Code of Federal Regulations, 2013 CFR
2013-10-01
... AND RELATED SYSTEMS Main Propulsion Machinery § 58.05-10 Automatic shut-off. Main propulsion machinery... controls must shut down main propulsion machinery in case of a failure, such as failure of the lubricating...
Lesion strength control by automatic temperature guided retinal photocoagulation.
Schlott, Kerstin; Koinzer, Stefan; Baade, Alexander; Birngruber, Reginald; Roider, Johann; Brinkmann, Ralf
2016-09-01
Laser photocoagulation is an established treatment for a variety of retinal diseases. However, when using the same irradiation parameter, the size and strength of the lesions are unpredictable due to unknown inter- and intraindividual optical properties of the fundus layers. The aim of this work is to investigate a feedback system to generate desired lesions of preselectable strengths by automatically controlling the irradiation time. Optoacoustics were used for retinal temperature monitoring. A 532-nm continuous wave Nd:YAG laser was used for photocoagulation. A 75-ns/523-nm Q-switched Nd:YLF laser simultaneously excited temperature-dependent pressure transients, which were detected at the cornea by an ultrasonic transducer embedded in a contact lens. The temperature data were analyzed during the irradiation by a LabVIEW routine. The treatment laser was switched off automatically when the required lesion strength was achieved. Five different feedback control algorithms for different lesion sizes were developed and tested on rabbits in vivo. With a laser spot diameter of 133???m, five different lesion types with ophthalmoscopically visible diameters ranging mostly between 100 and 200???m, and different appearances were achieved by automatic exposure time control. The automatically controlled lesions were widely independent of the treatment laser power and the retinal pigmentation.
Lesion strength control by automatic temperature guided retinal photocoagulation
NASA Astrophysics Data System (ADS)
Schlott, Kerstin; Koinzer, Stefan; Baade, Alexander; Birngruber, Reginald; Roider, Johann; Brinkmann, Ralf
2016-09-01
Laser photocoagulation is an established treatment for a variety of retinal diseases. However, when using the same irradiation parameter, the size and strength of the lesions are unpredictable due to unknown inter- and intraindividual optical properties of the fundus layers. The aim of this work is to investigate a feedback system to generate desired lesions of preselectable strengths by automatically controlling the irradiation time. Optoacoustics were used for retinal temperature monitoring. A 532-nm continuous wave Nd:YAG laser was used for photocoagulation. A 75-ns/523-nm Q-switched Nd:YLF laser simultaneously excited temperature-dependent pressure transients, which were detected at the cornea by an ultrasonic transducer embedded in a contact lens. The temperature data were analyzed during the irradiation by a LabVIEW routine. The treatment laser was switched off automatically when the required lesion strength was achieved. Five different feedback control algorithms for different lesion sizes were developed and tested on rabbits in vivo. With a laser spot diameter of 133 μm, five different lesion types with ophthalmoscopically visible diameters ranging mostly between 100 and 200 μm, and different appearances were achieved by automatic exposure time control. The automatically controlled lesions were widely independent of the treatment laser power and the retinal pigmentation.
Optimization of the High-speed On-off Valve of an Automatic Transmission
NASA Astrophysics Data System (ADS)
Li-mei, ZHAO; Huai-chao, WU; Lei, ZHAO; Yun-xiang, LONG; Guo-qiao, LI; Shi-hao, TANG
2018-03-01
The response time of the high-speed on-off solenoid valve has a great influence on the performance of the automatic transmission. In order to reduce the response time of the high-speed on-off valve, the simulation model of the valve was built by use of AMESim and Ansoft Maxwell softwares. To reduce the response time, an objective function based on ITAE criterion was built and the Genetic Algorithms was used to optimize five parameters including circle number, working air gap, et al. The comparison between experiment and simulation shows that the model is verified. After optimization, the response time of the valve is reduced by 38.16%, the valve can meet the demands of the automatic transmission well. The results can provide theoretical reference for the improvement of automatic transmission performance.
Earthquake Risk Reduction to Istanbul Natural Gas Distribution Network
NASA Astrophysics Data System (ADS)
Zulfikar, Can; Kariptas, Cagatay; Biyikoglu, Hikmet; Ozarpa, Cevat
2017-04-01
Earthquake Risk Reduction to Istanbul Natural Gas Distribution Network Istanbul Natural Gas Distribution Corporation (IGDAS) is one of the end users of the Istanbul Earthquake Early Warning (EEW) signal. IGDAS, the primary natural gas provider in Istanbul, operates an extensive system 9,867km of gas lines with 750 district regulators and 474,000 service boxes. The natural gas comes to Istanbul city borders with 70bar in 30inch diameter steel pipeline. The gas pressure is reduced to 20bar in RMS stations and distributed to district regulators inside the city. 110 of 750 district regulators are instrumented with strong motion accelerometers in order to cut gas flow during an earthquake event in the case of ground motion parameters exceeds the certain threshold levels. Also, state of-the-art protection systems automatically cut natural gas flow when breaks in the gas pipelines are detected. IGDAS uses a sophisticated SCADA (supervisory control and data acquisition) system to monitor the state-of-health of its pipeline network. This system provides real-time information about quantities related to pipeline monitoring, including input-output pressure, drawing information, positions of station and RTU (remote terminal unit) gates, slum shut mechanism status at 750 district regulator sites. IGDAS Real-time Earthquake Risk Reduction algorithm follows 4 stages as below: 1) Real-time ground motion data transmitted from 110 IGDAS and 110 KOERI (Kandilli Observatory and Earthquake Research Institute) acceleration stations to the IGDAS Scada Center and KOERI data center. 2) During an earthquake event EEW information is sent from IGDAS Scada Center to the IGDAS stations. 3) Automatic Shut-Off is applied at IGDAS district regulators, and calculated parameters are sent from stations to the IGDAS Scada Center and KOERI. 4) Integrated building and gas pipeline damage maps are prepared immediately after the earthquake event. The today's technology allows to rapidly estimate the expected level of shaking when an earthquake starts to occur. However, in Istanbul case for a potential Marmara Sea Earthquake, the time is very limited even to estimate the level of shaking. The robust threshold based EEW system is only algorithm for such a near source event to activate automatic shut-off mechanism in the critical infrastructures before the damaging waves arrive. This safety measure even with a few seconds of early warning time will help to mitigate potential damages and secondary hazards.
Gosch, D; Ratzmer, A; Berauer, P; Kahn, T
2007-09-01
The objective of this study was to examine the extent to which the image quality on mobile C-arms can be improved by an innovative exposure rate control system (grid control). In addition, the possible dose reduction in the pulsed fluoroscopy mode using 25 pulses/sec produced by automatic adjustment of the pulse rate through motion detection was to be determined. As opposed to conventional exposure rate control systems, which use a measuring circle in the center of the field of view, grid control is based on a fine mesh of square cells which are overlaid on the entire fluoroscopic image. The system uses only those cells for exposure control that are covered by the object to be visualized. This is intended to ensure optimally exposed images, regardless of the size, shape and position of the object to be visualized. The system also automatically detects any motion of the object. If a pulse rate of 25 pulses/sec is selected and no changes in the image are observed, the pulse rate used for pulsed fluoroscopy is gradually reduced. This may decrease the radiation exposure. The influence of grid control on image quality was examined using an anthropomorphic phantom. The dose reduction achieved with the help of object detection was determined by evaluating the examination data of 146 patients from 5 different countries. The image of the static phantom made with grid control was always optimally exposed, regardless of the position of the object to be visualized. The average dose reduction when using 25 pulses/sec resulting from object detection and automatic down-pulsing was 21 %, and the maximum dose reduction was 60 %. Grid control facilitates C-arm operation, since optimum image exposure can be obtained independently of object positioning. Object detection may lead to a reduction in radiation exposure for the patient and operating staff.
Design of Automatic Intensity Varying Smart Street Lighting System
NASA Astrophysics Data System (ADS)
Gupta, Ashutosh; Gupta, Shipra
2017-08-01
The paper is proposed with an aim of power conservation. In this era of development, it is essential to develop a streetlight that turns on and off automatically without human interference. To achieve this light sensor have been placed in each panel which turns the street light on and off automatically. For energy conservation cool-white LED’s have been used in street light panel and dimmer modules have been installed which changes the intensity of the streetlight depending on the darkness.
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.
Masa, Juan F; Corral, Jaime; Pereira, Ricardo; Duran-Cantolla, Joaquin; Cabello, Marta; Hernández-Blasco, Luis; Monasterio, Carmen; Alonso-Fernandez, Alberto; Chiner, Eusebi; Vázquez-Polo, Francisco-José; Montserrat, Jose M
2013-04-01
Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic and then manual for residual cases) compared with manual HRP scoring, and with in-hospital polysomnography. We included suspected SAHS patients in a multicentre study and assigned them to home and hospital protocols at random. We constructed receiver operating characteristic (ROC) curves for manual and automatic scoring. Diagnostic agreement for several cut-off points was explored and costs for two equally effective alternatives were calculated. Of 366 randomised patients, 348 completed the protocol. Manual scoring produced better ROC curves than automatic scoring. There was no sensitive automatic or subsequent manual HRP apnoea-hypopnoea index (AHI) cut-off point. The specific cut-off points for automatic and subsequent manual HRP scorings (AHI >25 and >20, respectively) had a specificity of 93% for automatic and 94% for manual scorings. The costs of manual protocol were 9% higher than sequential HRP protocol; these were 69% and 64%, respectively, of the cost of the polysomnography. A sequential HRP scoring protocol is a cost-effective alternative to polysomnography, although with limited cost savings compared to HRP manual scoring.
30 CFR 75.1403-4 - Criteria-Automatic elevators.
Code of Federal Regulations, 2010 CFR
2010-07-01
... appropriate on automatic elevators which will automatically shut-off the power and apply the brakes in the... telephone or other effective communication system by which aid or assistance can be obtained promptly. ...
Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki
2014-05-01
To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Gaze Tracking System for User Wearing Glasses
Gwon, Su Yeong; Cho, Chul Woo; Lee, Hyeon Chang; Lee, Won Oh; Park, Kang Ryoung
2014-01-01
Conventional gaze tracking systems are limited in cases where the user is wearing glasses because the glasses usually produce noise due to reflections caused by the gaze tracker's lights. This makes it difficult to locate the pupil and the specular reflections (SRs) from the cornea of the user's eye. These difficulties increase the likelihood of gaze detection errors because the gaze position is estimated based on the location of the pupil center and the positions of the corneal SRs. In order to overcome these problems, we propose a new gaze tracking method that can be used by subjects who are wearing glasses. Our research is novel in the following four ways: first, we construct a new control device for the illuminator, which includes four illuminators that are positioned at the four corners of a monitor. Second, our system automatically determines whether a user is wearing glasses or not in the initial stage by counting the number of white pixels in an image that is captured using the low exposure setting on the camera. Third, if it is determined that the user is wearing glasses, the four illuminators are turned on and off sequentially in order to obtain an image that has a minimal amount of noise due to reflections from the glasses. As a result, it is possible to avoid the reflections and accurately locate the pupil center and the positions of the four corneal SRs. Fourth, by turning off one of the four illuminators, only three corneal SRs exist in the captured image. Since the proposed gaze detection method requires four corneal SRs for calculating the gaze position, the unseen SR position is estimated based on the parallelogram shape that is defined by the three SR positions and the gaze position is calculated. Experimental results showed that the average gaze detection error with 20 persons was about 0.70° and the processing time is 63.72 ms per each frame. PMID:24473283
Exposure to violent video games increases automatic aggressiveness.
Uhlmann, Eric; Swanson, Jane
2004-02-01
The effects of exposure to violent video games on automatic associations with the self were investigated in a sample of 121 students. Playing the violent video game Doom led participants to associate themselves with aggressive traits and actions on the Implicit Association Test. In addition, self-reported prior exposure to violent video games predicted automatic aggressive self-concept, above and beyond self-reported aggression. Results suggest that playing violent video games can lead to the automatic learning of aggressive self-views.
The Fringe Reading Facility at the Max-Planck-Institut fuer Stroemungsforschung
NASA Astrophysics Data System (ADS)
Becker, F.; Meier, G. E. A.; Wegner, H.; Timm, R.; Wenskus, R.
1987-05-01
A Mach-Zehnder interferometer is used for optical flow measurements in a transonic wind tunnel. Holographic interferograms are reconstructed by illumination with a He-Ne-laser and viewed by a video camera through wide angle optics. This setup was used for investigating industrial double exposure holograms of truck tires in order to develop methods of automatic recognition of certain manufacturing faults. Automatic input is achieved by a transient recorder digitizing the output of a TV camera and transferring the digitized data to a PDP11-34. Interest centered around sequences of interferograms showing the interaction of vortices with a profile and subsequent emission of sound generated by this process. The objective is the extraction of quantitative data which relates to the emission of noise.
The Fringe Reading Facility at the Max-Planck-Institut fuer Stroemungsforschung
NASA Technical Reports Server (NTRS)
Becker, F.; Meier, G. E. A.; Wegner, H.; Timm, R.; Wenskus, R.
1987-01-01
A Mach-Zehnder interferometer is used for optical flow measurements in a transonic wind tunnel. Holographic interferograms are reconstructed by illumination with a He-Ne-laser and viewed by a video camera through wide angle optics. This setup was used for investigating industrial double exposure holograms of truck tires in order to develop methods of automatic recognition of certain manufacturing faults. Automatic input is achieved by a transient recorder digitizing the output of a TV camera and transferring the digitized data to a PDP11-34. Interest centered around sequences of interferograms showing the interaction of vortices with a profile and subsequent emission of sound generated by this process. The objective is the extraction of quantitative data which relates to the emission of noise.
Design of automatic leveling and centering system of theodolite
NASA Astrophysics Data System (ADS)
Liu, Chun-tong; He, Zhen-Xin; Huang, Xian-xiang; Zhan, Ying
2012-09-01
To realize the theodolite automation and improve the azimuth Angle measurement instrument, the theodolite automatic leveling and centering system with the function of leveling error compensation is designed, which includes the system solution, key components selection, the mechanical structure of leveling and centering, and system software solution. The redesigned leveling feet are driven by the DC servo motor; and the electronic control center device is installed. Using high precision of tilt sensors as horizontal skew detection sensors ensures the effectiveness of the leveling error compensation. Aiming round mark center is located using digital image processing through surface array CCD; and leveling measurement precision can reach the pixel level, which makes the theodolite accurate centering possible. Finally, experiments are conducted using the automatic leveling and centering system of the theodolite. The results show the leveling and centering system can realize automatic operation with high centering accuracy of 0.04mm.The measurement precision of the orientation angle after leveling error compensation is improved, compared with that of in the traditional method. Automatic leveling and centering system of theodolite can satisfy the requirements of the measuring precision and its automation.
Melles, Reinhilde J; ter Kuile, Moniek M; Dewitte, Marieke; van Lankveld, Jacques J D M; Brauer, Marieke; de Jong, Peter J
2014-03-01
The intense fear response to vaginal penetration in women with lifelong vaginismus, who have never been able to experience coitus, may reflect negative automatic and deliberate appraisals of vaginal penetration stimuli which might be modified by exposure treatment. The aim of this study is to examine whether (i) sexual stimuli elicit relatively strong automatic and deliberate threat associations in women with vaginismus, as well as relatively negative automatic and deliberate global affective associations, compared with symptom-free women; and (ii) these automatic and more deliberate attitudes can be modified by therapist-aided exposure treatment. A single target Implicit Association Test (st-IAT) was used to index automatic threat associations, and an Affective Simon Task (AST) to index global automatic affective associations. Participants were women with lifelong vaginismus (N = 68) and women without sexual problems (N = 70). The vaginismus group was randomly allocated to treatment (n = 34) and a waiting list control condition (n = 34). Indices of automatic threat were obtained by the st-IAT and automatic global affective associations by the AST, visual analogue scales (VAS) were used to assess deliberate appraisals of the sexual pictures (fear and global positive affect). More deliberate fear and less global positive affective associations with sexual stimuli were found in women with vaginismus. Following therapist-aided exposure treatment, the strength of fear was strongly reduced, whereas global positive affective associations were strengthened. Automatic associations did not differ between women with and without vaginismus and did not change following treatment. Relatively stronger negative (threat or global affect) associations with sexual stimuli in vaginismus appeared restricted to the deliberate level. Therapist-aided exposure treatment was effective in reducing subjective fear of sexual penetration stimuli and led to more global positive affective associations with sexual stimuli. The impact of exposure might be further improved by strengthening the association between vaginal penetration and positive affect (e.g., by using counter-conditioning techniques). © 2013 International Society for Sexual Medicine.
Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed
2018-01-01
Technologic advances have reduced medical radiation exposure while maintaining image quality. The purpose of this study was to determine the effects of the presence of total hip arthroplasty implants, compared with native hips, on radiation exposure of the most radiosensitive organs when manual and automatic exposure control settings are used. Detection probes were placed at six locations (stomach, sigmoid colon, right pelvic wall, left pelvic wall, pubic symphysis, and anterior pubic skin) in a cadaver. Radiographs were obtained with the use of manual and automatic exposure control protocols, with exposures recorded. A total hip arthroplasty implant was placed in the cadaver, probe positioning was confirmed, and the radiographs were repeated, with exposure values recorded. The control probe placed at the stomach had values ranging from 0.00 mSv to 0.01 mSv in protocols with and without implants. With the manual protocol, exposures in the pelvis ranged from 0.36 mSv to 2.74 mSv in the native hip and from 0.33 mSv to 2.24 mSv after implant placement. The increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 0.818; left pelvic wall, 1.381; sigmoid colon, 1.550; right pelvic wall, 0.917; and anterior pubic skin, 1.015. With automatic exposure control, exposures in the pelvis ranged from 0.07 mSv to 0.89 mSv in the native hip and from 0.21 mSv to 1.15 mSv after implant placement. With automatic exposure control, the increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 1.292; left pelvic wall, 1.476; sigmoid colon, 2.182; right pelvic wall, 3.000; and anterior pubic skin, 1.378. The amount of radiation to which patients are exposed as a result of medical procedures or imaging, and whether exposure is associated with an increased risk of malignant transformation, are the subject of ongoing debate. We found that after insertion of a total hip arthroplasty implant, exposure values increased threefold at some anatomic locations and surpassed 1 mSv, the generally accepted threshold for concern. Radiation exposure to radiosensitive organs increased up to threefold after total hip implantation with automatic exposure control and up to approximately 1.5 times with the manual protocol. Doses were greater with manual exposures than with automatic exposure control (except at the control probe on the stomach, where exposure was negligible, as expected). However, after implant placement, doses increased more with automatic exposure control than with manual exposure. This difference can be attributed to increased scatter and the difficulty of dose modification because of the density of the implant. Current radiographic protocols should be reassessed to determine if the benefits of frequent radiographs outweigh the newly demonstrated risks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruan, C; Sodickson, A; Hamberg, L
2016-06-15
Purpose: Apparent patient size in CT localizers varies with localizer type and patient positioning, resulting in variation in effective mAs as guided by Tube Current Modulation (TCM). Our aim was to investigate the effects of vertical off-centering on CTDI-vol when using different localizer types and TCM strengths. Methods: A CTDI body phantom was scanned using an abdominal protocol with three TCM strengths (Siemens Definition AS40, CAREDose4D; very weak, average, very strong). Data was acquired at 11 table height positions; with phantom center at isocenter and at 10 other positions between 142mm below and 53mm above. At each position, scans weremore » acquired using 5 different localizer types: PA, AP, Lateral, PA+Lateral, and Lateral+PA. CTDI-vol was recorded for the 165 combinations of table height, localizer type, and TCM strength, and magnification factors measured from localizer images. Results: Magnification factors from AP and PA localizers ranged from 0.79–1.11 and 1.35–0.91, respectively from lowest to highest positions (highest with phantom located closest to X-ray tube), with a smaller impact when using Lateral, PA+Lateral, Lateral+PA localizer types, all of which behaved similarly. For an average TCM strength and PA localizer, CTDI-vol ranged from 75% higher to 12% lower than the isocenter value for the lowest to highest table positions, respectively. For table positions ranging from lowest to highest, CTDI-vol ranged from −23% to 17% for AP, from −8% to 0.3% for lateral and from −7% to 1% for a combination of PA and Lateral in either order. Similar behavior was found for different TCM strengths, but effects were more pronounced for very strong compared with very weak modulation strengths. Conclusion: Patient off-centering substantially impacts radiation dose, which depends on the amount of vertical offcentering and type of the localizer used. The combination of PA and Lateral localizers is most robust against effects of patient off-centering.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... exposure control, image processing and reconstruction programs, patient and equipment supports, component..., acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and... may include was revised by adding automatic exposure control, image processing and reconstruction...
ERIC Educational Resources Information Center
Hevel, David; Tannehill, Dana, Ed.
This module is the eighth of nine modules in the competency-based Missouri Auto Mechanics Curriculum Guide. Six units cover: introduction to automatic transmission/transaxle; hydraulic control systems; transmission/transaxle diagnosis; automatic transmission/transaxle maintenance and adjustment; in-vehicle transmission repair; and off-car…
The Interplay between Automatic and Control Processes in Reading.
ERIC Educational Resources Information Center
Walczyk, Jeffrey J.
2000-01-01
Reviews prominent reading theories in light of their accounts of how automatic and control processes combine to produce successful text comprehension, and the trade-offs between the two. Presents the Compensatory-Encoding Model of reading, which explicates how, when, and why automatic and control processes interact. Notes important educational…
Boos, J; Meineke, A; Rubbert, C; Heusch, P; Lanzman, R S; Aissa, J; Antoch, G; Kröpil, P
2016-03-01
To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDIvol) and dose length product (DLP). Data of 36,523 examinations (131,527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDIvol and DLP were 51.3% and 52.8% of the national DRLs, respectively. CTDIvol and DLP reached 43.8% and 43.1% for abdominal CT (n=10,590), 66.6% and 69.6% for cranial CT (n=16,098) and 37.8% and 44.0% for chest CT (n=10,387) of the compared national DRLs, respectively. Overall, the CTDIvol exceeded national DRLs in 1.9% of the examinations, while the DLP exceeded national DRLs in 2.9% of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50% of the DRLs. The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50% of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments. • The newly developed software based on the DICOM-Structured Report enables large-scale cloud-based CT dose monitoring • The implemented software solution enables automated benchmarking in regard to national DRLs • The local radiation exposure from CT reached approximately 50 % of the national DRLs • The cloud-based approach offers great potential for multi-center dose analysis. © Georg Thieme Verlag KG Stuttgart · New York.
Benefits of Automatic Duplexing Fact Sheet
This resource provides a how-to duplex guide, informs the reader on the benefits and cost savings from automatic duplexing, and several off the shelf print management software options for your facility.
Automatic Locker Key With Barcode Based Microcontroller Atmega 8535
NASA Astrophysics Data System (ADS)
Fahmi, M. Irfan; Efendi Hutagalung, Jhonson
2017-12-01
MCB (miniature circuit breaker) is an electromagnetic device that embodies complete enclosure in a molded insulating material. The main function of an MCB is to switch the circuit, i.e., to open the circuit (which has been connected to it) automatically when the current passing through it (MCB) exceeds the value for which it is set. Unlike fuse, an MCB can be easily reset and thus offers improved operational safety and greater convenience without incurring large operating cost.The principal of operation is simple. In simple terms MCB is a switch which automatically turns off when the current flowing through it passes the maximum allowable limit. Generally MCB are designed to protect against over current and over temperature faults (over heating). Sometimes the overload the current through the bimetal causes to raise the temperature of it. The heat generated within the bimetal itself enough to cause deflection due to thermal expansion of metals. This solution is used by LDR, and LM 35 as the sencor to control center. Therefore it is very important because it is related about local control switches, isolating switches against faults and overload protection devices for installations or specific equipments or appliances
Lester, Corey A; Chui, Michelle A
2016-01-01
To determine the effect of an automatic prescription refill program on the prescription pickup lag in community pharmacy. A post-only quasi-experimental design comparing automatic and manual refill prescription cohorts for each of the 3 Centers for Medicare and Medicaid medication adherence metrics. A 29-store community pharmacy chain in the Midwest. Community-dwelling patients over the age of 65 years receiving prescription medications included in the statin, renin-angiotensin-aldosterone system antagonist, or non-insulin diabetes adherence metrics. An automatic prescription refill program that initiated prescription refills on a standardized, recurrent basis, eliminating the need for patients to phone in or drop off prescription refills. The prescription pickup lag, defined as the number of days between a prescription being adjudicated in the pharmacy and the prescription being picked up by the patient. A total of 37,207 prescription fills were examined. There were 20.5%, 22.4%, and 23.3% of patients enrolled in the automatic prescription refill program for the statin, renin-angiotensin-aldosterone system antagonist, and diabetes adherence metrics, respectively. Prescriptions in the automatic prescription refill cohorts experienced a median pickup lag of 7 days compared with 1 day for the manual refill prescriptions. 35.2% of all manual refill prescriptions had a pickup lag of 0 days compared with 13% for automatic refills. However, 15.4% of automatic prescription refills had a pickup lag of greater than 14 days, compared with 4.8% of manual refills. Prescriptions in the automatic prescription refill programs were associated with a significantly longer amount of time in the pharmacy before being picked up by the patient. This increased pickup lag may contribute positively by smoothing out workload demands of pharmacy staff, but may contribute negatively owing to an increased amount of rework and greater inventory requirements. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Koplan, Bruce A; Gilligan, David M; Nguyen, Luc S; Lau, Theodore K; Thackeray, Lisa M; Berg, Kellie Chase
2008-11-01
An automatic capture (AC) algorithm adjusts ventricular pacing output to capture the ventricle while optimizing output to 0.5 V above threshold. AC maintains this output and confirms capture on a beat-to-beat basis in bipolar and unipolar pacing and sensing. To assess the AC algorithm and its impact on device longevity. Patients implanted with a pacemaker were randomized 1:1 to have the AC feature on or off for 12 months. Two threshold tests were conducted at each visit- automatic threshold and manual threshold. Average ventricular voltage output and projected device longevity were compared between AC on and off using nonparametric tests. Nine hundred ten patients were enrolled and underwent device implantation. Average ventricular voltage output was 1.6 V for the AC on arm (n = 444) and 3.1 V for the AC off arm (n = 446) (P < 0.001). Projected device longevity was 10.3 years for AC on and 8.9 years for AC off (P < 0.0001), or a 16% increase in longevity for AC on. The proportion of patients in whom there was a difference between automatic threshold and manual threshold of
NASA Astrophysics Data System (ADS)
Applbaum, David; Dorman, Lev; Pustil'Nik, Lev; Sternlieb, Abraham; Zagnetko, Alexander; Zukerman, Igor
It is well known that during great SEP events, fluxes of energetic particles can be so big that the memory of computers and other electronics in space may be destroyed, and satellites and spacecraft may cease to function. According to the NOAA Space Weather Prediction Cen-ter, the following scales constitute dangerous solar radiation storms: S5-extreme (flux level of particles with energy ∼ 10 MeV more than 105 ); S4 - severe(f luxmorethan104 ); andS3 - strong(f luxmorethan103 ). In these persiods, it is necessary to switch off some of the electronics for a few hours energy particles (meaning those with a few GeV/nucleon and higher), whose transportation to Earthfrom the S20 minutes after they accelerate and escape into the solar wind) than the main bulk of the smaller energy particle 60 minutes later). Here we describe the principles and experience of the automatic function of the "SEP - Search" program. The positive result, showing the exact beginning of an SEP event on the Emilio Segre Observ 10.8GV ), is determined now automatically by simultaneously increasing by 2.5 St.Dev. in two sections of the ne search "programnext uses 1-mindata for checking whether or not the observed increase reflects the beginning Research "automatically starts to work online. We determine also the probabilities of false and missed alerts.
Exposure to Violent Video Games Increases Automatic Aggressiveness
ERIC Educational Resources Information Center
Uhlmann, Eric; Swanson, Jane
2004-01-01
The effects of exposure to violent video games on automatic associations with the self were investigated in a sample of 121 students. Playing the violent video game Doom led participants to associate themselves with aggressive traits and actions on the Implicit Association Test. In addition, self-reported prior exposure to violent video games…
European solvent industry group generic exposure scenario risk and exposure tool
Zaleski, Rosemary T; Qian, Hua; Zelenka, Michael P; George-Ares, Anita; Money, Chris
2014-01-01
The European Solvents Industry Group (ESIG) Generic Exposure Scenario (GES) Risk and Exposure Tool (EGRET) was developed to facilitate the safety evaluation of consumer uses of solvents, as required by the European Union Registration, Evaluation and Authorization of Chemicals (REACH) Regulation. This exposure-based risk assessment tool provides estimates of both exposure and risk characterization ratios for consumer uses. It builds upon the consumer portion of the European Center for Ecotoxicology and Toxicology of Chemicals (ECETOC) Targeted Risk Assessment (TRA) tool by implementing refinements described in ECETOC TR107. Technical enhancements included the use of additional data to refine scenario defaults and the ability to include additional parameters in exposure calculations. Scenarios were also added to cover all frequently encountered consumer uses of solvents. The TRA tool structure was modified to automatically determine conditions necessary for safe use. EGRET reports results using specific standard phrases in a format consistent with REACH exposure scenario guidance, in order that the outputs can be readily assimilated within safety data sheets and similar information technology systems. Evaluation of tool predictions for a range of commonly encountered consumer uses of solvents found it provides reasonable yet still conservative exposure estimates. PMID:23361440
European solvent industry group generic exposure scenario risk and exposure tool.
Zaleski, Rosemary T; Qian, Hua; Zelenka, Michael P; George-Ares, Anita; Money, Chris
2014-01-01
The European Solvents Industry Group (ESIG) Generic Exposure Scenario (GES) Risk and Exposure Tool (EGRET) was developed to facilitate the safety evaluation of consumer uses of solvents, as required by the European Union Registration, Evaluation and Authorization of Chemicals (REACH) Regulation. This exposure-based risk assessment tool provides estimates of both exposure and risk characterization ratios for consumer uses. It builds upon the consumer portion of the European Center for Ecotoxicology and Toxicology of Chemicals (ECETOC) Targeted Risk Assessment (TRA) tool by implementing refinements described in ECETOC TR107. Technical enhancements included the use of additional data to refine scenario defaults and the ability to include additional parameters in exposure calculations. Scenarios were also added to cover all frequently encountered consumer uses of solvents. The TRA tool structure was modified to automatically determine conditions necessary for safe use. EGRET reports results using specific standard phrases in a format consistent with REACH exposure scenario guidance, in order that the outputs can be readily assimilated within safety data sheets and similar information technology systems. Evaluation of tool predictions for a range of commonly encountered consumer uses of solvents found it provides reasonable yet still conservative exposure estimates.
Determinants of wood dust exposure in the Danish furniture industry.
Mikkelsen, Anders B; Schlunssen, Vivi; Sigsgaard, Torben; Schaumburg, Inger
2002-11-01
This paper investigates the relation between wood dust exposure in the furniture industry and occupational hygiene variables. During the winter 1997-98 54 factories were visited and 2362 personal, passive inhalable dust samples were obtained; the geometric mean was 0.95 mg/m(3) and the geometric standard deviation was 2.08. In a first measuring round 1685 dust concentrations were obtained. For some of the workers repeated measurements were carried out 1 (351) and 2 weeks (326) after the first measurement. Hygiene variables like job, exhaust ventilation, cleaning procedures, etc., were documented. A multivariate analysis based on mixed effects models was used with hygiene variables being fixed effects and worker, machine, department and factory being random effects. A modified stepwise strategy of model making was adopted taking into account the hierarchically structured variables and making possible the exclusion of non-influential random as well as fixed effects. For woodworking, the following determinants of exposure increase the dust concentration: manual and automatic sanding and use of compressed air with fully automatic and semi-automatic machines and for cleaning of work pieces. Decreased dust exposure resulted from the use of compressed air with manual machines, working at fully automatic or semi-automatic machines, functioning exhaust ventilation, work on the night shift, daily cleaning of rooms, cleaning of work pieces with a brush, vacuum cleaning of machines, supplementary fresh air intake and safety representative elected within the last 2 yr. For handling and assembling, increased exposure results from work at automatic machines and presence of wood dust on the workpieces. Work on the evening shift, supplementary fresh air intake, work in a chair factory and special cleaning staff produced decreased exposure to wood dust. The implications of the results for the prevention of wood dust exposure are discussed.
Compatibility of Automatic Exposure Control with New Screen Phosphors in Diagnostic Roentgenography.
NASA Astrophysics Data System (ADS)
Mulvaney, James Arthur
1982-03-01
Automatic exposure control systems are used in diagnostic roentgenography to obtain proper film density for a variety of patient examinations and roentgenographic techniques. Most automatic exposure control systems have been designed for use with par speed, calcium tungstate intensifying screens. The use of screens with faster speeds and new phosphor materials has put extreme demands on present systems. The performance of a representative automatic exposure control system is investigated to determine its ability to maintain constant film density over a wide range of x-ray tube voltages and acrylic phantom thicknesses with four different intensifying screen phosphors. The effects of x-ray energy dependence, generator switching time and stored change are investigated. The system is able to maintain film density to within plus or minus 0.2 optical density units for techniques representing adult patients. A single nonadjustable tube voltage compensation circuit is adequate for the four different screen phosphors for x-ray tube voltages above sixty peak kilovolts. For techniques representing pediatric patients at high x-ray tube voltages, excess film density occurs due to stored charge in the transformer and high-voltage cables. An anticipation circuit in the automatic exposure control circuit can be modified to correct for stored charge effects. In a separate experiment the energy dependence of three different ionization chamber detectors used in automatic exposure control systems is compared directly with the energy dependence of three different screen phosphors. The data on detector sensitivity and screen speed are combined to predict the best tube voltage compensation for each combination of screen and detector.
Pandora Operation and Analysis Software
NASA Technical Reports Server (NTRS)
Herman, Jay; Cede, Alexander; Abuhassan, Nader
2012-01-01
Pandora Operation and Analysis Software controls the Pandora Sun- and sky-pointing optical head and built-in filter wheels (neutral density, UV bandpass, polarization filters, and opaque). The software also controls the attached spectrometer exposure time and thermoelectric cooler to maintain the spectrometer temperature to within 1 C. All functions are available through a GUI so as to be easily accessible by the user. The data are automatically stored on a miniature computer (netbook) for automatic download to a designated server at user defined intervals (once per day, once per week, etc.), or to a USB external device. An additional software component reduces the raw data (spectrometer counts) to preliminary scientific products for quick-view purposes. The Pandora systems are built from off-the-shelf commercial parts and from mechanical parts machined using electronic machine shop drawings. The Pandora spectrometer system is designed to look at the Sun (tracking to within 0.1 ), or to look at the sky at any zenith or azimuth angle, to gather information about the amount of trace gases or aerosols that are present.
Funama, Yoshinori; Awai, Kazuo; Hatemura, Masahiro; Shimamura, Masamitchi; Yanaga, Yumi; Oda, Seitaro; Yamashita, Yasuyuki
2008-01-01
To investigate whether it is possible to obtain adequate images at uniform image noise levels and reduced radiation exposure with our automatic tube current modulation (ATCM) technique for 64-detector CT. The study population consisted of 64 patients with known or suspected lung or abdominal disease. We used a 64-detector CT scanner (LightSpeed VCT, GE Healthcare, Waukesha, WI, USA) and a combined angular and longitudinal tube current modulation technique (Smart mA, GE Healthcare, Waukesha, WI, USA) to examine 34 patients. The scanning parameters were identical; the minimum and maximum tube current thresholds were 50 and 800 mA, respectively. For study of the constant tube current technique, 30 additional patients were examined at 350 mA. The CT number and image noise (SD of the CT number) were measured in the 64 patients at six levels, i.e., the center of the left ventricle, the liver dome, the porta hepatis, the center of the spleen and the right and left renal pelvis. When we used the ATCM technique, the mean image noise ranged from 8.40 at the center of the left ventricle to 11.31 at the porta hepatis; the mean tube current ranged from 105.9 mAs at the center of the left ventricle to 169.6 mAs at the center of the spleen. The mean dose reduction rate per constant tube current at 175 mAs ranged from 3.1 to 39.5%. By use of the ATCM technique, it is possible to maintain a constant image noise level with a 64-detector CT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solis, R.P.; Chavez, F.C.; Garcia, S.E.
1997-12-31
In any operating geothermal power plant, steam quality is one of the most important parameters being monitored. In the Bacon-Manito Geothermal Production Field (BGPF), an online steam quality monitoring system have been installed in two operating power plants which provides an accurate, efficient and continuous real-time data which is more responsive to the various requirements of the field operation. The system utilizes sodium as an indicator of steam purity. Sodium concentration is read by the flame photometer located at the interface after aspirating a sample of the condensed steam through a continuous condensate sampler. The condensate has been degassed throughmore » a condensate-NCG separator. The flame photometer analog signal is then converted by a voltage-to-current converter/transmitter and relayed to the processor which is located at the control center through electrical cable to give a digital sodium concentration read-out at the control panel. The system features a high and high-high sodium level alarm, a continuous strip-chart recorder and a central computer for data capture, retrieval, and processing for further interpretation. Safety devices, such as the flame-off indicator at the control center and the automatic fuel cut-off device along the fuel line, are incorporated in the system.« less
Eidlin-Levy, Hili; Rubinsten, Orly
2017-01-01
The relationship between numbers and other magnitudes has been extensively investigated in the scientific literature. Here, the objectives were to examine whether two continuous magnitudes, area and perimeter, are automatically processed and whether adults with developmental dyscalculia (DD) are deficient in their ability to automatically process one or both of these magnitudes. Fifty-seven students (30 with DD and 27 with typical development) performed a novel Stroop-like task requiring estimation of one aspect (area or perimeter) while ignoring the other. In order to track possible changes in automaticity due to practice, we measured performance after initial and continuous exposure to stimuli. Similar to previous findings, current results show a significant group × congruency interaction, evident beyond exposure level or magnitude type. That is, the DD group systematically showed larger Stroop effects. However, analysis of each exposure period showed that during initial exposure to stimuli the DD group showed larger Stroop effects in the perimeter and not in the area task. In contrast, during continuous exposure to stimuli no triple interaction was evident. It is concluded that both magnitudes are automatically processed. Nevertheless, individuals with DD are deficient in inhibiting irrelevant magnitude information in general and, specifically, struggle to inhibit salient area information after initial exposure to a perimeter comparison task. Accordingly, the findings support the assumption that DD involves a deficiency in multiple cognitive components, which include domain-specific and domain-general cognitive functions.
Eidlin-Levy, Hili; Rubinsten, Orly
2017-01-01
The relationship between numbers and other magnitudes has been extensively investigated in the scientific literature. Here, the objectives were to examine whether two continuous magnitudes, area and perimeter, are automatically processed and whether adults with developmental dyscalculia (DD) are deficient in their ability to automatically process one or both of these magnitudes. Fifty-seven students (30 with DD and 27 with typical development) performed a novel Stroop-like task requiring estimation of one aspect (area or perimeter) while ignoring the other. In order to track possible changes in automaticity due to practice, we measured performance after initial and continuous exposure to stimuli. Similar to previous findings, current results show a significant group × congruency interaction, evident beyond exposure level or magnitude type. That is, the DD group systematically showed larger Stroop effects. However, analysis of each exposure period showed that during initial exposure to stimuli the DD group showed larger Stroop effects in the perimeter and not in the area task. In contrast, during continuous exposure to stimuli no triple interaction was evident. It is concluded that both magnitudes are automatically processed. Nevertheless, individuals with DD are deficient in inhibiting irrelevant magnitude information in general and, specifically, struggle to inhibit salient area information after initial exposure to a perimeter comparison task. Accordingly, the findings support the assumption that DD involves a deficiency in multiple cognitive components, which include domain-specific and domain-general cognitive functions. PMID:29312066
Automatic Lamp and Fan Control Based on Microcontroller
NASA Astrophysics Data System (ADS)
Widyaningrum, V. T.; Pramudita, Y. D.
2018-01-01
In general, automation can be described as a process following pre-determined sequential steps with a little or without any human exertion. Automation is provided with the use of various sensors suitable to observe the production processes, actuators and different techniques and devices. In this research, the automation system developed is an automatic lamp and an automatic fan on the smart home. Both of these systems will be processed using an Arduino Mega 2560 microcontroller. A microcontroller is used to obtain values of physical conditions through sensors connected to it. In the automatic lamp system required sensors to detect the light of the LDR (Light Dependent Resistor) sensor. While the automatic fan system required sensors to detect the temperature of the DHT11 sensor. In tests that have been done lamps and fans can work properly. The lamp can turn on automatically when the light begins to darken, and the lamp can also turn off automatically when the light begins to bright again. In addition, it can concluded also that the readings of LDR sensors are placed outside the room is different from the readings of LDR sensors placed in the room. This is because the light intensity received by the existing LDR sensor in the room is blocked by the wall of the house or by other objects. Then for the fan, it can also turn on automatically when the temperature is greater than 25°C, and the fan speed can also be adjusted. The fan may also turn off automatically when the temperature is less than equal to 25°C.
49 CFR Appendix B to Part 232 - Part 232 Prior to May 31, 2001 as Clarified Effective April 10, 2002
Code of Federal Regulations, 2010 CFR
2010-10-01
... coupled to train, after which, an automatic brake application and release test of airbrakes on rear car... closing angle cocks for cutting off one or more cars from the rear end of train, automatic air brake must... automatic air brake must not be depended upon to hold a locomotive, cars or train, when standing on a grade...
49 CFR Appendix B to Part 232 - Part 232 Prior to May 31, 2001 as Clarified Effective April 10, 2002
Code of Federal Regulations, 2011 CFR
2011-10-01
... coupled to train, after which, an automatic brake application and release test of airbrakes on rear car... closing angle cocks for cutting off one or more cars from the rear end of train, automatic air brake must... automatic air brake must not be depended upon to hold a locomotive, cars or train, when standing on a grade...
Curcumin as a positive resist dye optimized for g- and h-line exposure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Renschler, C.L.; Stiefeld, R.E.; Rodriguez, J.L.
1987-06-01
It has now been firmly established, both theoretically and experimentally, that the addition of a non-bleachable absorber (or dye) to photoresist can reduce notching and other linewidth control variations associated with the patterning of reflective surfaces. Such variations are due to two separate, but closely related, effects. The first of these effects is reflection of light off scattering centers on the substrate at angles other than surface-normal.
Auditory, Vestibular and Cognitive Effects due to Repeated Blast Exposure on the Warfighter
2012-10-01
Gaze Horizontal (Left and Right) Description: The primary purpose of the Gaze Horizontal subtest was to detect nystagmus when the head is fixed and...to detect nystagmus when the head is fixed and the eyes are gazing off center from the primary (straight ahead) gaze position. This test is designed...physiological target area and examiner instructions for testing): Spontaneous Nystagmus Smooth Harmonic Acceleration (.01, .08, .32, .64, 1.75
Koch, Saskia B J; Klumpers, Floris; Zhang, Wei; Hashemi, Mahur M; Kaldewaij, Reinoud; van Ast, Vanessa A; Smit, Annika S; Roelofs, Karin
2017-01-01
Background : Control over automatic tendencies is often compromised in challenging situations when people fall back on automatic defensive reactions, such as freeze - fight - flight responses. Stress-induced lack of control over automatic defensive responses constitutes a problem endemic to high-risk professions, such as the police. Difficulties controlling automatic defensive responses may not only impair split-second decisions under threat, but also increase the risk for and persistence of posttraumatic stress disorder (PTSD) symptoms. However, the significance of these automatic defensive responses in the development and maintenance of trauma-related symptoms remains unclear due to a shortage of large-scale prospective studies. Objective : The 'Police-in-Action' study is conducted to investigate the role of automatic defensive responses in the development and maintenance of PTSD symptomatology after trauma exposure. Methods : In this prospective study, 340 police recruits from the Dutch Police Academy are tested before (wave 1; pre-exposure) and after (wave 2; post-exposure) their first emergency aid experiences as police officers. The two waves of data assessment are separated by approximately 15 months. To control for unspecific time effects, a well-matched control group of civilians ( n = 85) is also tested twice, approximately 15 months apart, but without being frequently exposed to potentially traumatic events. Main outcomes are associations between (changes in) behavioural, psychophysiological, endocrine and neural markers of automatic defensive responses and development of trauma-related symptoms after trauma exposure in police recruits. Discussion : This prospective study in a large group of primary responders enables us to distinguish predisposing from acquired neurobiological abnormalities in automatic defensive responses, associated with the development of trauma-related symptoms. Identifying neurobiological correlates of (vulnerability for) trauma-related psychopathology may greatly improve screening for individuals at risk for developing PTSD symptomatology and offer valuable targets for (early preventive) interventions for PTSD.
Aerial applications dispersal systems control requirements study. [agriculture
NASA Technical Reports Server (NTRS)
Bauchspies, J. S.; Cleary, W. L.; Rogers, W. F.; Simpson, W.; Sanders, G. S.
1980-01-01
Performance deficiencies in aerial liquid and dry dispersal systems are identified. Five control system concepts are explored: (1) end of field on/off control; (2) manual control of particle size and application rate from the aircraft; (3) manual control of deposit rate on the field; (4) automatic alarm and shut-off control; and (5) fully automatic control. Operational aspects of the concepts and specifications for improved control configurations are discussed in detail. A research plan to provide the technology needed to develop the proposed improvements is presented along with a flight program to verify the benefits achieved.
NASA Technical Reports Server (NTRS)
Collins, E. R., Jr.
1985-01-01
Coal cutting and removal done with minimal hazard to people. Automatic coal mine cutting, transport and roof-support movement all done by automatic machinery. Exposure of people to hazardous conditions reduced to inspection tours, maintenance, repair, and possibly entry mining.
1969-07-16
CAPE CANAVERAL, Fla. -- The American Flag heralds the flight of Apollo 11, man's first lunar landing mission. This double exposure was made with a 1,000 mm lens. The photograph was taken from Cape Kennedy, adjacent to Kennedy Space Center, where Apollo 11 lifted off from pad 39A at 9:32 a.m. EDT. This image was imposed upon the image of hte flag, filmed a day earlier. In the photo, the rocket at an alititude of about 5,000 feet. A band of super-cold propellants seems to circle the rocket near its center. The effect is caused by the difference in temperature between the propellants and the atmosphere. Photo credit: NASA
40 CFR 63.685 - Standards: Tanks.
Code of Federal Regulations, 2011 CFR
2011-07-01
... organic-contaminated debris is dumped from roll-off boxes or dump trucks, and then this debris is promptly... roof except for automatic bleeder vents (vacuum breaker vents) and the rim space vents is to provide a... gasketed cover or a gasketed lid except for leg sleeves, automatic bleeder vents, rim space vents, column...
40 CFR 63.685 - Standards: Tanks.
Code of Federal Regulations, 2014 CFR
2014-07-01
... organic-contaminated debris is dumped from roll-off boxes or dump trucks, and then this debris is promptly... roof except for automatic bleeder vents (vacuum breaker vents) and the rim space vents is to provide a... gasketed cover or a gasketed lid except for leg sleeves, automatic bleeder vents, rim space vents, column...
40 CFR 63.685 - Standards: Tanks.
Code of Federal Regulations, 2013 CFR
2013-07-01
... organic-contaminated debris is dumped from roll-off boxes or dump trucks, and then this debris is promptly... roof except for automatic bleeder vents (vacuum breaker vents) and the rim space vents is to provide a... gasketed cover or a gasketed lid except for leg sleeves, automatic bleeder vents, rim space vents, column...
40 CFR 63.685 - Standards: Tanks.
Code of Federal Regulations, 2012 CFR
2012-07-01
... organic-contaminated debris is dumped from roll-off boxes or dump trucks, and then this debris is promptly... roof except for automatic bleeder vents (vacuum breaker vents) and the rim space vents is to provide a... gasketed cover or a gasketed lid except for leg sleeves, automatic bleeder vents, rim space vents, column...
ERIC Educational Resources Information Center
National Bureau of Standards (DOC), Washington, DC.
These guidelines provide a handbook for use by federal organizations in structuring physical security and risk management programs for their automatic data processing facilities. This publication discusses security analysis, natural disasters, supporting utilities, system reliability, procedural measures and controls, off-site facilities,…
NASA Astrophysics Data System (ADS)
Applbaum, David; Dorman, Lev; Pustil'Nik, Lev; Sternlieb, Abraham; Zagnetko, Alexander; Zukerman, Igor
In Applbaum et al. (2010) it was described how the "SEP-Search" program works automat-ically, determining on the basis of on-line one-minute NM data the beginning of a great SEP event. The "SEP-Search" next uses one-minute data in order to check whether or not the observed increase reflects the beginning of a real great SEP event. If yes, the program "SEP-Research/Spectrum" automatically starts to work on line. We consider two variants: 1) quiet period (no change in cut-off rigidity), 2) disturbed period (characterized with possible changing of cut-off rigidity). We describe the method of determining the spectrum of SEP in the 1st vari-ant (for this we need data for at least two components with different coupling functions). For the 2nd variant we need data for at least three components with different coupling functions. We show that for these purposes one can use data of the total intensity and some different mul-tiplicities, but that it is better to use data from two or three NM with different cut-off rigidities. We describe in detail the algorithms of the program "SEP-Research/Spectrum." We show how this program worked on examples of some historical great SEP events. The work of NM on Mt. Hermon is supported by Israel (Tel Aviv University and ISA) -Italian (UNIRoma-Tre and IFSI-CNR) collaboration.
Garg, Satish; Brazg, Ronald L; Bailey, Timothy S; Buckingham, Bruce A; Slover, Robert H; Klonoff, David C; Shin, John; Welsh, John B; Kaufman, Francine R
2012-03-01
The efficacy of automatic suspension of insulin delivery in induced hypoglycemia among subjects with type 1 diabetes was evaluated. In this randomized crossover study, subjects used a sensor-augmented insulin pump system with a low glucose suspend (LGS) feature that automatically stops insulin delivery for 2 h following a sensor glucose (SG) value ≤70 mg/dL. Subjects fasted overnight and exercised until their plasma glucose (measured with the YSI 2300 STAT Plus™ glucose and lactate analyzer [YSI Life Sciences, Yellow Springs, OH]) value reached ≤85 mg/dL on different occasions separated by washout periods lasting 3-10 days. Exercise sessions were done with the LGS feature turned on (LGS-On) or with continued insulin delivery regardless of SG value (LGS-Off). The order of LGS-On and LGS-Off sessions was randomly assigned. YSI glucose data were used to compare the duration and severity of hypoglycemia from successful LGS-On and LGS-Off sessions and to estimate the risk of rebound hyperglycemia after pump suspension. Fifty subjects attempted 134 sessions, 98 of which were successful. The mean±SD hypoglycemia duration was less during LGS-On than during LGS-Off sessions (138.5±76.68 vs. 170.7±75.91 min, P=0.006). During LGS-On compared with LGS-Off sessions, mean nadir YSI glucose was higher (59.5±5.72 vs. 57.6±5.69 mg/dL, P=0.015), as was mean end-observation YSI glucose (91.4±41.84 vs. 66.2±13.48 mg/dL, P<0.001). Most (53.2%) end-observation YSI glucose values in LGS-On sessions were in the 70-180 mg/dL range, and none was >250 mg/dL. Automatic suspension of insulin delivery significantly reduced the duration and severity of induced hypoglycemia without causing rebound hyperglycemia.
NASA's Lunar Impact Monitoring Program
NASA Technical Reports Server (NTRS)
Suggs, Robert M.; Cooke, William; Swift, Wesley; Hollon, Nicholas
2007-01-01
NASA's Meteoroid Environment Office nas implemented a program to monitor the Moon for meteoroid impacts from the Marshall Space Flight Center. Using off-the-shelf telescopes and video equipment, the moon is monitored for as many as 10 nights per month, depending on weather. Custom software automatically detects flashes which are confirmed by a second telescope, photometrically calibrated using background stars, and published on a website for correlation with other observations, Hypervelocity impact tests at the Ames Vertical Gun Facility have been performed to determine the luminous efficiency ana ejecta characteristics. The purpose of this research is to define the impact ejecta environment for use by lunar spacecraft designers of the Constellation (manned lunar) Program. The observational techniques and preliminary results will be discussed.
Automatic evaluations and exercise setting preference in frequent exercisers.
Antoniewicz, Franziska; Brand, Ralf
2014-12-01
The goals of this study were to test whether exercise-related stimuli can elicit automatic evaluative responses and whether automatic evaluations reflect exercise setting preference in highly active exercisers. An adapted version of the Affect Misattribution Procedure was employed. Seventy-two highly active exercisers (26 years ± 9.03; 43% female) were subliminally primed (7 ms) with pictures depicting typical fitness center scenarios or gray rectangles (control primes). After each prime, participants consciously evaluated the "pleasantness" of a Chinese symbol. Controlled evaluations were measured with a questionnaire and were more positive in participants who regularly visited fitness centers than in those who reported avoiding this exercise setting. Only center exercisers gave automatic positive evaluations of the fitness center setting (partial eta squared = .08). It is proposed that a subliminal Affect Misattribution Procedure paradigm can elicit automatic evaluations to exercising and that, in highly active exercisers, these evaluations play a role in decisions about the exercise setting rather than the amounts of physical exercise. Findings are interpreted in terms of a dual systems theory of social information processing and behavior.
Williams, Isobel Anne; Wilkinson, Leonora; Limousin, Patricia; Jahanshahi, Marjan
2015-01-01
Deep brain stimulation of the subthalamic nucleus (STN DBS) ameliorates the motor symptoms of Parkinson's disease (PD). However, some aspects of executive control are impaired with STN DBS. We tested the prediction that (i) STN DBS interferes with switching from automatic to controlled processing during fast-paced random number generation (RNG) (ii) STN DBS-induced cognitive control changes are load-dependent. Fifteen PD patients with bilateral STN DBS performed paced-RNG, under three levels of cognitive load synchronised with a pacing stimulus presented at 1, 0.5 and 0.33 Hz (faster rates require greater cognitive control), with DBS on or off. Measures of output randomness were calculated. Countscore 1 (CS1) indicates habitual counting in steps of one (CS1). Countscore 2 (CS2) indicates a more controlled strategy of counting in twos. The fastest rate was associated with an increased CS1 score with STN DBS on compared to off. At the slowest rate, patients had higher CS2 scores with DBS off than on, such that the differences between CS1 and CS2 scores disappeared. We provide evidence for a load-dependent effect of STN DBS on paced RNG in PD. Patients could switch to more controlled RNG strategies during conditions of low cognitive load at slower rates only when the STN stimulators were off, but when STN stimulation was on, they engaged in more automatic habitual counting under increased cognitive load. These findings are consistent with the proposal that the STN implements a switch signal from the medial frontal cortex which enables a shift from automatic to controlled processing.
Williams, Isobel Anne; Wilkinson, Leonora; Limousin, Patricia; Jahanshahi, Marjan
2015-01-01
Background: Deep brain stimulation of the subthalamic nucleus (STN DBS) ameliorates the motor symptoms of Parkinson’s disease (PD). However, some aspects of executive control are impaired with STN DBS. Objective: We tested the prediction that (i) STN DBS interferes with switching from automatic to controlled processing during fast-paced random number generation (RNG) (ii) STN DBS-induced cognitive control changes are load-dependent. Methods: Fifteen PD patients with bilateral STN DBS performed paced-RNG, under three levels of cognitive load synchronised with a pacing stimulus presented at 1, 0.5 and 0.33 Hz (faster rates require greater cognitive control), with DBS on or off. Measures of output randomness were calculated. Countscore 1 (CS1) indicates habitual counting in steps of one (CS1). Countscore 2 (CS2) indicates a more controlled strategy of counting in twos. Results: The fastest rate was associated with an increased CS1 score with STN DBS on compared to off. At the slowest rate, patients had higher CS2 scores with DBS off than on, such that the differences between CS1 and CS2 scores disappeared. Conclusions: We provide evidence for a load-dependent effect of STN DBS on paced RNG in PD. Patients could switch to more controlled RNG strategies during conditions of low cognitive load at slower rates only when the STN stimulators were off, but when STN stimulation was on, they engaged in more automatic habitual counting under increased cognitive load. These findings are consistent with the proposal that the STN implements a switch signal from the medial frontal cortex which enables a shift from automatic to controlled processing. PMID:25720447
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, G; Li, K; Gomez-Cardona, D
Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positionsmore » using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.« less
Effects of AEC chamber selection on patient dose and image quality.
Hawking, Nancy; Elmore, Angie
2009-01-01
To determine whether manipulation of the standard automatic exposure control (AEC) chamber selections reduces the patient's entrance skin exposure (ESE) without compromising image quality. Data for density and radiation dose were gathered at 2 clinical locations by exposing abdomen and pelvis phantoms to radiation using 3 AEC chamber selection configurations. ESE (skin dose) was measured using a multipurpose dosimeter. The experiment included both film-screen and computed radiography (CR) systems. For both phantoms, using the 2 outside chambers resulted in the lowest dose on the film-screen and CR systems. In general, optical density (OD) and exposure indicator (EI) remained within acceptable ranges and image quality was maintained using this chamber configuration. Using only the center chamber resulted in the highest dose increases and lowest image quality for film-screen and CR systems. When performing anteroposterior (AP) abdomen and AP pelvis examinations, radiographers can reduce patients' ESE and maintain image quality by selecting the 2 outside AEC chambers. Further research on AEC chamber selection should be conducted for additional anatomical regions.
NASA Astrophysics Data System (ADS)
Ohnuma, Hidetoshi; Kawahira, Hiroichi
1998-09-01
An automatic alternative phase shift mask (PSM) pattern layout tool has been newly developed. This tool is dedicated for embedded DRAM in logic device to shrink gate line width with improving line width controllability in lithography process with a design rule below 0.18 micrometers by the KrF excimer laser exposure. The tool can crete Levenson type PSM used being coupled with a binary mask adopting a double exposure method for positive photo resist. By using graphs, this tool automatically creates alternative PSM patterns. Moreover, it does not give any phase conflicts. By adopting it to actual embedded DRAM in logic cells, we have provided 0.16 micrometers gate resist patterns at both random logic and DRAM areas. The patterns were fabricated using two masks with the double exposure method. Gate line width has been well controlled under a practical exposure-focus window.
Army gas-cooled reactor systems program. Preliminary design report off-normal scram system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bushnell, W.H.; Malmstrom, S.A.
1965-06-01
The maximum allowable ML-1 fuel element cladding (hot spot) temperature is established by ANTS 201 at 1750/sup 0/F. The existing ML-1 design makes no provision for automatic scram when this limit is reached. Operating experience has indicated a requirement for such an automatic system during plant startup and a revised hot spot envelope (generated during conceptual design of the scram system) established the desirability of extending this protection to operation at full power conditions. It was also determined that the scram system should include circuitry to initiate an automatic scram if reactor ..delta..T exceeded 450/sup 0/F (the limit established inmore » ANTS 201) and if reactor power exceeded 6 kw(t) without coolant flow in the main loop. The preliminary design of the scram system (designated off-normal scram system) which will provide the required protection is described.« less
Program (USAP) sister projects focusing on observational Antarctic meteorological research, providing real -Madison Antarctic Meteorological Research Center & Automatic Weather Stations Project The Antarctic Meteorological Research Center (AMRC) and Automatic Weather Station (AWS) program are United States Antarctic
Wind Tunnel Testing of Powered Lift, All-Wing STOL Model
NASA Technical Reports Server (NTRS)
Collins, Scott W.; Westra, Bryan W.; Lin, John C.; Jones, Gregory S.; Zeune, Cal H.
2008-01-01
Short take-off and landing (STOL) systems can offer significant capabilities to warfighters and, for civil operators thriving on maximizing efficiencies they can improve airspace use while containing noise within airport environments. In order to provide data for next generation systems, a wind tunnel test of an all-wing cruise efficient, short take-off and landing (CE STOL) configuration was conducted in the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) 14- by 22-foot Subsonic Wind Tunnel. The test s purpose was to mature the aerodynamic aspects of an integrated powered lift system within an advanced mobility configuration capable of CE STOL. The full-span model made use of steady flap blowing and a lifting centerbody to achieve high lift coefficients. The test occurred during April through June of 2007 and included objectives for advancing the state-of-the-art of powered lift testing through gathering force and moment data, on-body pressure data, and off-body flow field measurements during automatically controlled blowing conditions. Data were obtained for variations in model configuration, angles of attack and sideslip, blowing coefficient, and height above ground. The database produced by this effort is being used to advance design techniques and computational tools for developing systems with integrated powered lift technologies.
Modeling Off-Nominal Recovery in NextGen Terminal-Area Operations
NASA Technical Reports Server (NTRS)
Callantine, Todd J.
2011-01-01
Robust schedule-based arrival management requires efficient recovery from off-nominal situations. This paper presents research on modeling off-nominal situations and plans for recovering from them using TRAC, a route/airspace design, fast-time simulation, and analysis tool for studying NextGen trajectory-based operations. The paper provides an overview of a schedule-based arrival-management concept and supporting controller tools, then describes TRAC implementations of methods for constructing off-nominal scenarios, generating trajectory options to meet scheduling constraints, and automatically producing recovery plans.
Compressible sleeve provides automatic centering for grinding or turning of cylinders
NASA Technical Reports Server (NTRS)
Rohrer, J. A.
1968-01-01
Elastomeric sleeve supported on a threaded mandrel automatically centers cylindrical castings for grinding or turning. By expanding the diameter of the sleeve with pressure against the ends, the casting becomes rigidly supported and the surfacing operation can be completed.
Hitchcock, Penny J; Mair, Michael; Inglesby, Thomas V; Gross, Jonathan; Henderson, D A; O'Toole, Tara; Ahern-Seronde, Joa; Bahnfleth, William P; Brennan, Terry; Burroughs, H E Barney; Davidson, Cliff; Delp, William; Ensor, David S; Gomory, Ralph; Olsiewski, Paula; Samet, Jonathan M; Smith, William M; Streifel, Andrew J; White, Ronald H; Woods, James E
2006-01-01
The prospect of biological attacks is a growing strategic threat. Covert aerosol attacks inside a building are of particular concern. In the summer of 2005, the Center for Biosecurity of the University of Pittsburgh Medical Center convened a Working Group to determine what steps could be taken to reduce the risk of exposure of building occupants after an aerosol release of a biological weapon. The Working Group was composed of subject matter experts in air filtration, building ventilation and pressurization, air conditioning and air distribution, biosecurity, building design and operation, building decontamination and restoration, economics, medicine, public health, and public policy. The group focused on functions of the heating, ventilation, and air conditioning systems in commercial or public buildings that could reduce the risk of exposure to deleterious aerosols following biological attacks. The Working Group's recommendations for building owners are based on the use of currently available, off-the-shelf technologies. These recommendations are modest in expense and could be implemented immediately. It is also the Working Group's judgment that the commitment and stewardship of a lead government agency is essential to secure the necessary financial and human resources and to plan and build a comprehensive, effective program to reduce exposure to aerosolized infectious agents in buildings.
Stern, Alan H.; Gochfeld, Michael; Lioy, Paul J.
2014-01-01
During much of the twentieth century, Jersey City, New Jersey was the leading center of chromate production in the United States. Chromate production produced huge volumes of chromium ore-processing residue containing many parts per million of hexavalent chromium. Starting in the 1990s, we undertook a series of studies to identify exposed populations, sources and pathways of exposure and the effectiveness of remediation activities in Jersey City. These studies revealed the effectiveness and success of the remediation activities. The sequence of studies presented here, builds on the lessons learned from each preceding study and illustrates how these studies advanced the field of exposure science in important ways, including the use of household dust as a measure of exposure to contaminants originating in the outdoor environment; development of effective and reproducible dust sampling; use of household dust to track temporal changes in exposure; understanding of the spatial relationship between sources of passive outdoor particulate emissions and residential exposure; use of focused biomonitoring to assess exposure under conditions of large inter-individual variability; and utility of linking environmental monitoring and biomonitoring. For chromium, the studies have demonstrated the use of Cr+6-specific analytical methods for measuring low concentrations of Cr+6 in household dust and understanding of the occurrence of Cr+6 in the background residential environment. We strongly recommend that environmental and public health agencies evaluate sites for their potential for off-site exposure and apply these tools in cases with significant potential as appropriate. This approach is especially important when contamination is widespread and/or a large population is potentially exposed. In such cases, these tools should be used to identify, characterize and then reduce the exposure to the off-site as well as on-site population. Importantly, these tools can be used in a demonstrable and quantifiable manner to provide both clarity and closure to concerned stakeholders. PMID:23131713
System for automatically switching transformer coupled lines
NASA Technical Reports Server (NTRS)
Dwinell, W. S. (Inventor)
1979-01-01
A system is presented for automatically controlling transformer coupled alternating current electric lines. The secondary winding of each transformer is provided with a center tap. A switching circuit is connected to the center taps of a pair of secondary windings and includes a switch controller. An impedance is connected between the center taps of the opposite pair of secondary windings. The switching circuit has continuity when the AC lines are continuous and discontinuity with any disconnect of the AC lines. Normally open switching means are provided in at least one AC line. The switch controller automatically opens the switching means when the AC lines become separated.
Spill-Detector-and-Shutoff Device
NASA Technical Reports Server (NTRS)
Jarvis, M. R.; Fulton, D. S.
1985-01-01
Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.
46 CFR 154.708 - Cargo boil-off as fuel: Valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.708 Cargo boil-off as fuel: Valves. (a) Gas fuel lines to the gas consuming equipment must have two fail-closed automatic valves in series. A third valve, designed to fail...
46 CFR 154.708 - Cargo boil-off as fuel: Valves.
Code of Federal Regulations, 2010 CFR
2010-10-01
... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.708 Cargo boil-off as fuel: Valves. (a) Gas fuel lines to the gas consuming equipment must have two fail-closed automatic valves in series. A third valve, designed to fail...
46 CFR 154.708 - Cargo boil-off as fuel: Valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.708 Cargo boil-off as fuel: Valves. (a) Gas fuel lines to the gas consuming equipment must have two fail-closed automatic valves in series. A third valve, designed to fail...
46 CFR 154.708 - Cargo boil-off as fuel: Valves.
Code of Federal Regulations, 2014 CFR
2014-10-01
... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.708 Cargo boil-off as fuel: Valves. (a) Gas fuel lines to the gas consuming equipment must have two fail-closed automatic valves in series. A third valve, designed to fail...
46 CFR 154.708 - Cargo boil-off as fuel: Valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Pressure and Temperature Control § 154.708 Cargo boil-off as fuel: Valves. (a) Gas fuel lines to the gas consuming equipment must have two fail-closed automatic valves in series. A third valve, designed to fail...
Phase-lock loop frequency control and the dropout problem
NASA Technical Reports Server (NTRS)
Attwood, S.; Kline, A. J.
1968-01-01
Technique automatically sets the frequency of narrow band phase-lock loops within automatic lock-in-range. It presets a phase-lock loop to a desired center frequency with a closed loop electronic frequency discriminator and holds the phase-lock loop to that center frequency until lock is achieved.
Applying face identification to detecting hijacking of airplane
NASA Astrophysics Data System (ADS)
Luo, Xuanwen; Cheng, Qiang
2004-09-01
That terrorists hijacked the airplanes and crashed the World Trade Center is disaster to civilization. To avoid the happening of hijack is critical to homeland security. To report the hijacking in time, limit the terrorist to operate the plane if happened and land the plane to the nearest airport could be an efficient way to avoid the misery. Image processing technique in human face recognition or identification could be used for this task. Before the plane take off, the face images of pilots are input into a face identification system installed in the airplane. The camera in front of pilot seat keeps taking the pilot face image during the flight and comparing it with pre-input pilot face images. If a different face is detected, a warning signal is sent to ground automatically. At the same time, the automatic cruise system is started or the plane is controlled by the ground. The terrorists will have no control over the plane. The plane will be landed to a nearest or appropriate airport under the control of the ground or cruise system. This technique could also be used in automobile industry as an image key to avoid car stealth.
Automatic control of solar power plants
NASA Astrophysics Data System (ADS)
Ermakov, V. S.; Dubilovich, V. M.
1982-02-01
The automatic control of the heliostat field of a 200-MW solar power plant is discussed. The advantages of the decentralized control principle with the solution of a number of individual problems in a single control center are emphasized. The basic requirements on heliostat construction are examined, and possible functional schemes for the automatic control of a heliostat field are described. It is proposed that groups of heliostats can be controlled from a single center and on the basis of a single algorithm.
Automatic control design procedures for restructurable aircraft control
NASA Technical Reports Server (NTRS)
Looze, D. P.; Krolewski, S.; Weiss, J.; Barrett, N.; Eterno, J.
1985-01-01
A simple, reliable automatic redesign procedure for restructurable control is discussed. This procedure is based on Linear Quadratic (LQ) design methodologies. It employs a robust control system design for the unfailed aircraft to minimize the effects of failed surfaces and to extend the time available for restructuring the Flight Control System. The procedure uses the LQ design parameters for the unfailed system as a basis for choosing the design parameters of the failed system. This philosophy alloys the engineering trade-offs that were present in the nominal design to the inherited by the restructurable design. In particular, it alloys bandwidth limitations and performance trade-offs to be incorporated in the redesigned system. The procedure also has several other desirable features. It effectively redistributes authority among the available control effectors to maximize the system performance subject to actuator limitations and constraints. It provides a graceful performance degradation as the amount of control authority lessens. When given the parameters of the unfailed aircraft, the automatic redesign procedure reproduces the nominal control system design.
Ubiquitous Stereo Vision for Controlling Safety on Platforms in Railroad Station
NASA Astrophysics Data System (ADS)
Yoda, Ikushi; Hosotani, Daisuke; Sakaue, Katushiko
Dozens of people are killed every year when they fall off of train platforms, making this an urgent issue to be addressed by the railroads, especially in the major cities. This concern prompted the present work that is now in progress to develop a Ubiquitous Stereo Vision based system for safety management at the edge of rail station platforms. In this approach, a series of stereo cameras are installed in a row on the ceiling that are pointed downward at the edge of the platform to monitor the disposition of people waiting for the train. The purpose of the system is to determine automatically and in real-time whether anyone or anything is in the danger zone at the very edge of the platform, whether anyone has actually fallen off the platform, or whether there is any sign of these things happening. The system could be configured to automatically switch over to a surveillance monitor or automatically connect to an emergency brake system in the event of trouble.
Integration of wireless sensor networks into automatic irrigation scheduling of a center pivot
USDA-ARS?s Scientific Manuscript database
A six-span center pivot system was used as a platform for testing two wireless sensor networks (WSN) of infrared thermometers. The cropped field was a semi-circle, divided into six pie shaped sections of which three were irrigated manually and three were irrigated automatically based on the time tem...
47 CFR 54.637 - Off-site data centers and off-site administrative offices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Healthcare Connect Fund § 54.637 Off-site data centers and off-site administrative offices. (a) The... the Healthcare Connect Fund, subject to the conditions and restrictions set forth in paragraph (b) of...
47 CFR 54.637 - Off-site data centers and off-site administrative offices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Healthcare Connect Fund § 54.637 Off-site data centers and off-site administrative offices. (a) The... the Healthcare Connect Fund, subject to the conditions and restrictions set forth in paragraph (b) of...
Day, Rachael; Eddleston, Michael; Thomas, Simon H L; Thompson, John P; Vale, J Allister
2016-11-01
Soluble film automatic dishwashing tablets, unlike their traditional counterparts, require no removal from an outer protective wrapper prior to use. Instead, the tablets are enclosed by a water-soluble polyvinyl alcohol film and are loaded straight into the dishwashing machine. They most commonly contain a source of hydrogen peroxide (often as sodium percarbonate) and non-ionic surfactants. Other constituents in some formulations include sodium carbonate, sodium tripolyphosphate and sodium silicate, which reduce water hardness. The pH once dissolved in water is alkaline. To determine the toxicity from exposure to soluble film automatic dishwashing tablets. Telephone enquiries to the United Kingdom National Poisons Information Service regarding soluble film automatic dishwashing products were analysed retrospectively for the period January 2008 to December 2015. There were 498 enquiries relating to 488 patients. Almost all exposures occurred in the home (98.4%) and involved children aged ≤5 years (92.8%). Exposure occurred mainly as a result of ingestion alone (n = 470, 96.3%); eye contact alone (n = 9, 1.8%) and exposures involving multiple routes (ingestion with skin or eye contact; n = 9, 1.8%) made up the remaining cases. The majority of patients were asymptomatic following exposure (n = 325, 67.4%). The most common feature following ingestion was vomiting which occurred in 121 of 474 cases (25.5%) where clinical data were available. Nausea (n = 8, 1.7%) and coughing (n = 6, 1.3%) were also reported; three patients developed stomatitis and another five developed a rash where ingestion alone was considered to be the sole route of exposure. Ocular exposure to the tablet contents resulted in blurred vision, eye pain or conjunctivitis in seven of ten patients. Ingestion of a soluble film automatic dishwashing tablet rarely resulted in clinically significant symptoms, which is surprising given the potential hazard of the ingredients. Hence, it seems probable that the amount of material actually ingested was very small or that most was spat out.
Automatic Exposure Control Device for Digital Mammography
2001-08-01
developing innovative approaches for controlling DM exposures. These approaches entail using the digital detector and an artificial neural network to...of interest that determine the exposure parameters for the fully exposed image; and (2) to use an artificial neural network to select exposure
Automatic Exposure Control Device for Digital Mammography
2004-08-01
developing innovative approaches for controlling DM exposures. These approaches entail using the digital detector and an artificial neural network to...of interest that determine the exposure parameters for the fully exposed image; and (2) to use an artificial neural network to select exposure
Self-actuating grapple automatically engages and releases loads from overhead cranes
NASA Technical Reports Server (NTRS)
Froehlich, J. A.; Karastas, G. A.
1966-01-01
Two-piece grapple mechanism consisting of a lift knob secured to the load and a grapple member connected to the crane or lift automatically disengages the load from the overhead lifting device when the load contacts the ground. The key feature is the sliding collar under the lift knob which enables the grapple latch to be stripped off over the lift knob.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Z; Vijayan, S; Rana, V
2015-06-15
Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to readmore » data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.« less
OFF-CENTER SPHERICAL MODEL FOR DOSIMETRY CALCULATIONS IN CHICK BRAIN TISSUE
The paper presents calculations for the electric field and absorbed power density distribution in chick brain tissue inside a test tube, using an off-center spherical model. It is shown that the off-center spherical model overcomes many of the limitations of the concentric spheri...
Automatic patient dose registry and clinical audit on line for mammography.
Ten, J I; Vano, E; Sánchez, R; Fernandez-Soto, J M
2015-07-01
The use of automatic registry systems for patient dose in digital mammography allows clinical audit and patient dose analysis of the whole sample of individual mammography exposures while fulfilling the requirements of the European Directives and other international recommendations. Further parameters associated with radiation exposure (tube voltage, X-ray tube output and HVL values for different kVp and target/filter combinations, breast compression, etc.) should be periodically verified and used to evaluate patient doses. This study presents an experience in routine clinical practice for mammography using automatic systems. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Migiyama, Go; Sugimura, Atsuhiko; Osa, Atsushi; Miike, Hidetoshi
Recently, digital cameras are offering technical advantages rapidly. However, the shot image is different from the sight image generated when that scenery is seen with the naked eye. There are blown-out highlights and crushed blacks in the image that photographed the scenery of wide dynamic range. The problems are hardly generated in the sight image. These are contributory cause of difference between the shot image and the sight image. Blown-out highlights and crushed blacks are caused by the difference of dynamic range between the image sensor installed in a digital camera such as CCD and CMOS and the human visual system. Dynamic range of the shot image is narrower than dynamic range of the sight image. In order to solve the problem, we propose an automatic method to decide an effective exposure range in superposition of edges. We integrate multi-step exposure images using the method. In addition, we try to erase pseudo-edges using the process to blend exposure values. Afterwards, we get a pseudo wide dynamic range image automatically.
TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, A; Gazi, P; Department of Radiology, UC Davis Medical Center, Sacramento, CA
Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determiningmore » the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.« less
The Language Exposure Assessment Tool: Quantifying Language Exposure in Infants and Children
ERIC Educational Resources Information Center
DeAnda, Stephanie; Bosch, Laura; Poulin-Dubois, Diane; Zesiger, Pascal; Friend, Margaret
2016-01-01
Purpose: The aim of this study was to develop the Language Exposure Assessment Tool (LEAT) and to examine its cross-linguistic validity, reliability, and utility. The LEAT is a computerized interview-style assessment that requests parents to estimate language exposure. The LEAT yields an automatic calculation of relative language exposure and…
Multiseasonal Tree Crown Structure Mapping with Point Clouds from OTS Quadrocopter Systems
NASA Astrophysics Data System (ADS)
Hese, S.; Behrendt, F.
2017-08-01
OTF (Off The Shelf) quadro copter systems provide a cost effective (below 2000 Euro), flexible and mobile platform for high resolution point cloud mapping. Various studies showed the full potential of these small and flexible platforms. Especially in very tight and complex 3D environments the automatic obstacle avoidance, low copter weight, long flight times and precise maneuvering are important advantages of these small OTS systems in comparison with larger octocopter systems. This study examines the potential of the DJI Phantom 4 pro series and the Phantom 3A series for within-stand and forest tree crown 3D point cloud mapping using both within stand oblique imaging in different altitude levels and data captured from a nadir perspective. On a test site in Brandenburg/Germany a beach crown was selected and measured with 3 different altitude levels in Point Of Interest (POI) mode with oblique data capturing and deriving one nadir mosaic created with 85/85 % overlap using Drone Deploy automatic mapping software. Three different flight campaigns were performed, one in September 2016 (leaf-on), one in March 2017 (leaf-off) and one in May 2017 (leaf-on) to derive point clouds from different crown structure and phenological situations - covering the leaf-on and leafoff status of the tree crown. After height correction, the point clouds where used with GPS geo referencing to calculate voxel based densities on 50 × 10 × 10 cm voxel definitions using a topological network of chessboard image objects in 0,5 m height steps in an object based image processing environment. Comparison between leaf-off and leaf-on status was done on volume pixel definitions comparing the attributed point densities per volume and plotting the resulting values as a function of distance to the crown center. In the leaf-off status SFM (structure from motion) algorithms clearly identified the central stem and also secondary branch systems. While the penetration into the crown structure is limited in the leaf-on status (the point cloud is a mainly a description of the interpolated crown surface) - the visibility of the internal crown structure in leaf-off status allows to map also the internal tree structure up to and stopping at the secondary branch level system. When combined the leaf-on and leaf-off point clouds generate a comprehensive tree crown structure description that allows a low cost and detailed 3D crown structure mapping and potentially precise biomass mapping and/or internal structural differentiation of deciduous tree species types. Compared to TLS (Terrestrial Laser Scanning) based measurements the costs are neglectable and in the range of 1500-2500 €. This suggests the approach for low cost but fine scale in-situ applications and/or projects where TLS measurements cannot be derived and for less dense forest stands where POI flights can be performed. This study used the in-copter GPS measurements for geo referencing. Better absolute geo referencing results will be obtained with DGPS reference points. The study however clearly demonstrates the potential of OTS very low cost copter systems and the image attributed GPS measurements of the copter for the automatic calculation of complex 3D point clouds in a multi temporal tree crown mapping context.
Effects of voluntary and automatic control of center of pressure sway during quiet standing.
Ueta, Kozo; Okada, Yohei; Nakano, Hideki; Osumi, Michihiro; Morioka, Shu
2015-01-01
The authors investigated the effects of voluntary and automatic control on the spatial variables (envelope area, maximal amplitude, and root mean square [RMS]) of center of pressure (COP) displacement during quiet standing and identified differences in their postural control strategies (mean velocity [MV], mean power frequency [MPF], and power density). COP data were recorded under relaxed (experimental control), still (voluntary control), and dual (automatic control) conditions. RMS was significantly lower in the still and dual conditions than in the relaxed condition. MV, MPF, and power density were significantly higher in the still condition than in the dual condition. These results indicate that both voluntary and automatic control decrease the spatial variables of COP displacement; however, their postural control strategies are different.
NASA Astrophysics Data System (ADS)
Han, Minah; Baek, Jongduk
2017-03-01
We investigate location dependent lesion detectability of cone beam computed tomography images for different background types (i.e., uniform and anatomical), image planes (i.e., transverse and longitudinal) and slice thicknesses. Anatomical backgrounds are generated using a power law spectrum of breast anatomy, 1/f3. Spherical object with a 5mm diameter is used as a signal. CT projection data are acquired by the forward projection of uniform and anatomical backgrounds with and without the signal. Then, projection data are reconstructed using the FDK algorithm. Detectability is evaluated by a channelized Hotelling observer with dense difference-of-Gaussian channels. For uniform background, off-centered images yield higher detectability than iso-centered images for the transverse plane, while for the longitudinal plane, detectability of iso-centered and off-centered images are similar. For anatomical background, off-centered images yield higher detectability for the transverse plane, while iso-centered images yield higher detectability for the longitudinal plane, when the slice thickness is smaller than 1.9mm. The optimal slice thickness is 3.8mm for all tasks, and the transverse plane at the off-center (iso-center and off-center) produces the highest detectability for uniform (anatomical) background.
Method of center localization for objects containing concentric arcs
NASA Astrophysics Data System (ADS)
Kuznetsova, Elena G.; Shvets, Evgeny A.; Nikolaev, Dmitry P.
2015-02-01
This paper proposes a method for automatic center location of objects containing concentric arcs. The method utilizes structure tensor analysis and voting scheme optimized with Fast Hough Transform. Two applications of the proposed method are considered: (i) wheel tracking in video-based system for automatic vehicle classification and (ii) tree growth rings analysis on a tree cross cut image.
Automatic, sterile, and apyrogenic delivery of PET radiotracers from the cyclotron to the patient
NASA Astrophysics Data System (ADS)
Votaw, J. R.; Cashion, D. B.; Clanton, J. A.
1991-05-01
An automatic delivery remote injection system has been developed to administer either 13N-labelled ammonia, or 15O-labelled water or 18F-labelled FDG to patients. Automation increases the throughout and efficiency of the PET center, and remote dose administration ensures patient safety and reduces the radiation exposure to the technologist supervising the radiopharmaceutical injection. The remote dose administration apparatus utilizes a syringe pump to transfer liquid activity and a solenoid three-way valve to switch between lines connected to a patient and a receiving vial. To ensure apyrogenicity and sterility of the injected product, the entire system is washed with sterile water before it is used. Since the tracer is delivered in an ~ 8 ml bolus of water, the next delivery through the system is considered safe for injection if pyrogens are not detected at a threshold of 3 endotoxin units per ml (EU/ml) in the wash. Time delayed tests shows that the system may be left unused for up to 6 h before the wash must be repeated.
Advanced metal lift-off process using electron-beam flood exposure of single-layer photoresist
NASA Astrophysics Data System (ADS)
Minter, Jason P.; Ross, Matthew F.; Livesay, William R.; Wong, Selmer S.; Narcy, Mark E.; Marlowe, Trey
1999-06-01
In the manufacture of many types of integrated circuit and thin film devices, it is desirable to use a lift-of process for the metallization step to avoid manufacturing problems encountered when creating metal interconnect structures using plasma etch. These problems include both metal adhesion and plasma etch difficulties. Key to the success of the lift-off process is the creation of a retrograde or undercut profile in the photoresists before the metal deposition step. Until now, lift-off processing has relied on costly multi-layer photoresists schemes, image reversal, and non-repeatable photoresist processes to obtain the desired lift-off profiles in patterned photoresist. This paper present a simple, repeatable process for creating robust, user-defined lift-off profiles in single layer photoresist using a non-thermal electron beam flood exposure. For this investigation, lift-off profiles created using electron beam flood exposure of many popular photoresists were evaluated. Results of lift-off profiles created in positive tone AZ7209 and ip3250 are presented here.
NASA Technical Reports Server (NTRS)
Simpson, Amy A.; Wilson, Jennifer G.; Brown, Robert G.
2015-01-01
Data from multiple sources is needed to investigate lightning characteristics over differing terrain (on-shore vs. off-shore) by comparing natural cloud-to-ground lightning behavior differences depending on the characteristics of attachment mediums. The KSC Lightning Research Database (KLRD) was created to reduce manual data entry time and aid research by combining information from various data sources into a single record for each unique lightning event of interest. The KLRD uses automatic data handling functions to import data from a lightning detection network and identify and record lighting events of interest. Additional automatic functions import data from the NASA Buoy 41009 (located approximately 20 miles off the coast) and the KSC Electric Field Mill network, then match these electric field mill values to the corresponding lightning events. The KLRD calculates distances between each lightning event and the various electric field mills, aids in identifying the location type for each stroke (i.e., on-shore vs. off-shore, etc.), provides statistics on the number of strokes per flash, and produces customizable reports for quick retrieval and logical display of data. Data from February 2014 to date covers 48 unique storm dates with 2295 flashes containing 5700 strokes, of which 2612 are off-shore and 1003 are on-shore. The number of strokes per flash ranges from 1 to 22. The ratio of single to subsequent stroke flashes is 1.29 for off-shore strokes and 2.19 for on-shore strokes.
75 FR 8570 - Atlantic Ocean off John F. Kennedy Space Center, FL; Restricted Area
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-25
... off John F. Kennedy Space Center, FL; Restricted Area AGENCY: United States Army Corps of Engineers... the Atlantic Ocean off the coast of the John F. Kennedy Space Center (KSC), Florida. The KSC is the main launch facility for the National Aeronautics and Space Administration (NASA) and they need to have...
Reading between the Lines: Accessing Information via "Youtube's" Automatic Captioning
ERIC Educational Resources Information Center
Smith, Chad; Allman, Tamby; Crocker, Samantha
2017-01-01
This study and discussion center upon the use of "YouTube's" automatic captioning feature with college-age adult readers. The study required 75 participants with college experience to view brief middle school science videos with automatic captioning on "YouTube" and answer comprehension questions based on material presented…
40 CFR 265.16 - Personnel training.
Code of Federal Regulations, 2013 CFR
2013-07-01
... automatic waste feed cut-off systems; (iii) Communications or alarm -systems; (iv) Response to fires or... bargaining unit, but must include the requisite skill, education, or other qualifications, and duties of...
40 CFR 265.16 - Personnel training.
Code of Federal Regulations, 2012 CFR
2012-07-01
... automatic waste feed cut-off systems; (iii) Communications or alarm -systems; (iv) Response to fires or... bargaining unit, but must include the requisite skill, education, or other qualifications, and duties of...
40 CFR 265.16 - Personnel training.
Code of Federal Regulations, 2014 CFR
2014-07-01
... automatic waste feed cut-off systems; (iii) Communications or alarm -systems; (iv) Response to fires or... bargaining unit, but must include the requisite skill, education, or other qualifications, and duties of...
33 CFR 334.525 - Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. 334.525 Section 334.525 Navigation and Navigable Waters CORPS... REGULATIONS § 334.525 Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. (a) The area. The...
33 CFR 334.525 - Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. 334.525 Section 334.525 Navigation and Navigable Waters CORPS... REGULATIONS § 334.525 Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. (a) The area. The...
33 CFR 334.525 - Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. 334.525 Section 334.525 Navigation and Navigable Waters CORPS... REGULATIONS § 334.525 Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. (a) The area. The...
33 CFR 334.525 - Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. 334.525 Section 334.525 Navigation and Navigable Waters CORPS... REGULATIONS § 334.525 Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. (a) The area. The...
33 CFR 334.525 - Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. 334.525 Section 334.525 Navigation and Navigable Waters CORPS... REGULATIONS § 334.525 Atlantic Ocean off John F. Kennedy Space Center, FL; restricted area. (a) The area. The...
75 FR 34643 - Atlantic Ocean Off John F. Kennedy Space Center, FL; Restricted Area
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-18
... Off John F. Kennedy Space Center, FL; Restricted Area AGENCY: U.S. Army Corps of Engineers, DoD... establishing a new restricted area in the Atlantic Ocean off the coast of the John F. Kennedy Space Center (KSC), Florida. The KSC is the main launch facility for the National Aeronautics and Space Administration (NASA...
Asymmetric dee-voltage compensation of beam off-centering in the milan superconducting cyclotron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milinkovic, Lj.; Fabrici, E.; Ostojic, R.
1985-10-01
An analysis of the effects of orbit off-centering on the beam extraction in the Milan superconducting cyclotron is made, and the sensitivity of axial beam loss and radial phase space distortions to beam off-centering determined for various acceleration conditions. We conclude that the first field harmonic compensation of beam off-centering is ineffective in the region of the operating diagram where the Walkinshaw resonance precedes the ..nu.. /SUB r/ =1 resonance. Asymmetric dee-voltage compensation is considered in these cases, and the domain of validity of the method determined. A semi-empirical relation for dee-voltage distribution is deduced, and the extraction efficiency discussed.
[Performance evaluation of CT automatic exposure control on fast dual spiral scan].
Niwa, Shinji; Hara, Takanori; Kato, Hideki; Wada, Yoichi
2014-11-01
The performance of individual computed tomography automatic exposure control (CT-AEC) is very important for radiation dose reduction and image quality equalization in CT examinations. The purpose of this study was to evaluate the performance of CT-AEC in conventional pitch mode (Normal spiral) and fast dual spiral scan (Flash spiral) in a 128-slice dual-source CT scanner. To evaluate the response properties of CT-AEC in the 128-slice DSCT scanner, a chest phantom was placed on the patient table and was fixed at the center of the field of view (FOV). The phantom scan was performed using Normal spiral and Flash spiral scanning. We measured the effective tube current time product (Eff. mAs) of simulated organs in the chest phantom along the longitudinal (z) direction, and the dose dependence (distribution) of in-plane locations for the respective scan modes was also evaluated by using a 100-mm-long pencil-type ionization chamber. The dose length product (DLP) was evaluated using the value displayed on the console after scanning. It was revealed that the response properties of CT-AEC in Normal spiral scanning depend on the respective pitches and Flash spiral scanning is independent of the respective pitches. In-plane radiation dose of Flash spiral was lower than that of Normal spiral. The DLP values showed a difference of approximately 1.7 times at the maximum. The results of our experiments provide information for adjustments for appropriate scanning parameters using CT-AEC in a 128-slice DSCT scanner.
Shah, Sneha; Quek, Samuel; Ruck, Bruce
2016-02-01
The American Association of Poison Control Center's annual reports demonstrate that acute fluoride exposure is not an uncommon occurrence. Despite its prevalence, there has been little published research on the topic in the last 10 years. The purpose of this study was to calculate the incidence of acute fluoride toxicity and lethality as it occurs in New Jersey and provide a descriptive epidemiology of acute fluoride exposures. The study design was retrospective in nature. Records of phone calls made by individuals reporting excessive fluoride exposure (in an amount greater than directed/prescribed) to New Jersey's poison control center, known as Poison Information and Education System from the years 2010 through 2012, were extracted from Toxicall® (Computer Automatic Systems, Inc.) database. A total of 2,476 human-only exposure records met the inclusion criteria and were analyzed. Incidence rates were calculated, and population characteristics, circumstances and medical outcomes of acute fluoride exposure cases were assessed and categorized. A total of 2,476 phone call records met the inclusion criteria. The fluoride exposures reported were from toothpaste with fluoride (49%, n=1,214), mouth rinse with fluoride (21.6%, n=536), multivitamin with fluoride (21.4%, n=530) and pure fluoride (0.08%, n=199). Medically speaking, 94.75% of calls were asymptomatic cases (n=2,346), 4.24% were symptomatic (n=105) and 1.01% were informational inquiries (n=25). Adverse symptoms reported were mostly minor (83.9% of symptomatic cases, n=88) and moderate (16.1% of symptomatic cases, n=17). The age group 18 months to 3 years of age showed the highest incidence of acute fluoride exposure (53.2%, n=1,317). There was a slightly higher incidence of acute fluoride exposures among males (n=1,317) vs. females (n=1,159). Most incidences occurred in the home (93.1% of records, n=2,305) and occurred unintentionally (96.7%, n=2,394). Calls were mainly made by the subject's mother (67.5%, n=1,671). Based on the data, there were no reports of lethality or toxicity due to acute fluoride exposure in New Jersey from 2010 through 2012. Symptomatic reports and informational inquiries were few. All adverse outcomes due to excessive fluoride intake were remedied with calcium as the antidote. Dental hygienists should educate patients on safety measures of fluoride-containing products and evaluate overall fluoride exposure prior to making recommendations. However, findings in this study suggest that levels of fluoride in available commercial products will not produce life-threatening events, even if taken in doses higher than recommended. Copyright © 2016 The American Dental Hygienists’ Association.
Ye, Xiaohua; Li, LiXia; Gao, Yanhui; Zhou, Shudong; Yang, Yi; Chen, Sidong
2015-09-30
A growing body of evidence indicates a strong association between smoking and depression. However, little is known about the possible effects of second-hand smoke (SHS) exposure on depression. This study aimed to examine the potential dose-response relation between SHS exposure and depressive symptoms among non-smoking middle-aged women. A cross-sectional survey was conducted using a stratified three-stage sampling method. Depressive symptoms were measured by the Center for Epidemiologic Studies Depression Scale with a cut-off point of 16. Self-reported SHS exposure was defined as non-smokers׳ inhalation of the smoke exhaled from smokers on at least one day a week. The multivariable logistic regression analysis was completed with adjustment for potential confounders. Among 1280 middle-aged women, 19.4% were classified as having depressive symptoms. There was a 104% increased odds of depressive symptoms corresponding to SHS exposure in general (OR=2.04, 95% CI 1.48-2.79) using no exposure as reference. There were significant positive relations between SHS exposure in general and depressive symptoms in a dose-response manner. These significant trends were observed consistently whether SHS exposure occurred in homes or workplaces. Our findings suggest that long-term and regular SHS exposure is associated with a significant, dose-dependent increase in risk of depressive symptoms. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Elimination of water pathogens with solar radiation using an automated sequential batch CPC reactor.
Polo-López, M I; Fernández-Ibáñez, P; Ubomba-Jaswa, E; Navntoft, C; García-Fernández, I; Dunlop, P S M; Schmid, M; Byrne, J A; McGuigan, K G
2011-11-30
Solar disinfection (SODIS) of water is a well-known, effective treatment process which is practiced at household level in many developing countries. However, this process is limited by the small volume treated and there is no indication of treatment efficacy for the user. Low cost glass tube reactors, together with compound parabolic collector (CPC) technology, have been shown to significantly increase the efficiency of solar disinfection. However, these reactors still require user input to control each batch SODIS process and there is no feedback that the process is complete. Automatic operation of the batch SODIS process, controlled by UVA-radiation sensors, can provide information on the status of the process, can ensure the required UVA dose to achieve complete disinfection is received and reduces user work-load through automatic sequential batch processing. In this work, an enhanced CPC photo-reactor with a concentration factor of 1.89 was developed. The apparatus was automated to achieve exposure to a pre-determined UVA dose. Treated water was automatically dispensed into a reservoir tank. The reactor was tested using Escherichia coli as a model pathogen in natural well water. A 6-log inactivation of E. coli was achieved following exposure to the minimum uninterrupted lethal UVA dose. The enhanced reactor decreased the exposure time required to achieve the lethal UVA dose, in comparison to a CPC system with a concentration factor of 1.0. Doubling the lethal UVA dose prevented the need for a period of post-exposure dark inactivation and reduced the overall treatment time. Using this reactor, SODIS can be automatically carried out at an affordable cost, with reduced exposure time and minimal user input. Copyright © 2011 Elsevier B.V. All rights reserved.
Device for timing and power level setting for microwave applications
NASA Astrophysics Data System (ADS)
Ursu, M.-P.; Buidoş, T.
2016-08-01
Nowadays, the microwaves are widely used for various technological processes. The microwaves are emitted by magnetrons, which have strict requirements concerning power supplies for anode and filament cathodes, intensity of magnetic field, cooling and electromagnetic shielding. The magnetrons do not tolerate any alteration of their required voltages, currents and magnetic fields, which means that their output microwave power is fixed, so the only way to alter the power level is to use time-division, by turning the magnetron on and off by repetitive time patterns. In order to attain accurate and reproducible results, as well as correct and safe operation of the microwave device, all these requirements must be fulfilled. Safe, correct and reproducible operation of the microwave appliance can be achieved by means of a specially built electronic device, which ensures accurate and reproducible exposure times, interlocking of the commands and automatic switch off when abnormal operating conditions occur. This driving device, designed and realized during the completion of Mr.Ursu's doctoral thesis, consists of a quartz time-base, several programmable frequency and duration dividers, LED displays, sensors and interlocking gates. The active and passive electronic components are placed on custom-made PCB's, designed and made by means of computer-aided applications and machines. The driving commands of the electronic device are delivered to the magnetron power supplies by means of optic zero-passing relays. The inputs of the electronic driving device can sense the status of the microwave appliance. The user is able to enter the total exposure time, the division factor that sets the output power level and, as a novelty, the clock frequency of the time divider.
NASA Astrophysics Data System (ADS)
Wang, Yang; Wang, Qianqian
2008-12-01
When laser ranger is transported or used in field operations, the transmitting axis, receiving axis and aiming axis may be not parallel. The nonparallelism of the three-light-axis will affect the range-measuring ability or make laser ranger not be operated exactly. So testing and adjusting the three-light-axis parallelity in the production and maintenance of laser ranger is important to ensure using laser ranger reliably. The paper proposes a new measurement method using digital image processing based on the comparison of some common measurement methods for the three-light-axis parallelity. It uses large aperture off-axis paraboloid reflector to get the images of laser spot and white light cross line, and then process the images on LabVIEW platform. The center of white light cross line can be achieved by the matching arithmetic in LABVIEW DLL. And the center of laser spot can be achieved by gradation transformation, binarization and area filter in turn. The software system can set CCD, detect the off-axis paraboloid reflector, measure the parallelity of transmitting axis and aiming axis and control the attenuation device. The hardware system selects SAA7111A, a programmable vedio decoding chip, to perform A/D conversion. FIFO (first-in first-out) is selected as buffer.USB bus is used to transmit data to PC. The three-light-axis parallelity can be achieved according to the position bias between them. The device based on this method has been already used. The application proves this method has high precision, speediness and automatization.
Use of Semi-Autonomous Tools for ISS Commanding and Monitoring
NASA Technical Reports Server (NTRS)
Brzezinski, Amy S.
2014-01-01
As the International Space Station (ISS) has moved into a utilization phase, operations have shifted to become more ground-based with fewer mission control personnel monitoring and commanding multiple ISS systems. This shift to fewer people monitoring more systems has prompted use of semi-autonomous console tools in the ISS Mission Control Center (MCC) to help flight controllers command and monitor the ISS. These console tools perform routine operational procedures while keeping the human operator "in the loop" to monitor and intervene when off-nominal events arise. Two such tools, the Pre-positioned Load (PPL) Loader and Automatic Operators Recorder Manager (AutoORM), are used by the ISS Communications RF Onboard Networks Utilization Specialist (CRONUS) flight control position. CRONUS is responsible for simultaneously commanding and monitoring the ISS Command & Data Handling (C&DH) and Communications and Tracking (C&T) systems. PPL Loader is used to uplink small pieces of frequently changed software data tables, called PPLs, to ISS computers to support different ISS operations. In order to uplink a PPL, a data load command must be built that contains multiple user-input fields. Next, a multiple step commanding and verification procedure must be performed to enable an onboard computer for software uplink, uplink the PPL, verify the PPL has incorporated correctly, and disable the computer for software uplink. PPL Loader provides different levels of automation in both building and uplinking these commands. In its manual mode, PPL Loader automatically builds the PPL data load commands but allows the flight controller to verify and save the commands for future uplink. In its auto mode, PPL Loader automatically builds the PPL data load commands for flight controller verification, but automatically performs the PPL uplink procedure by sending commands and performing verification checks while notifying CRONUS of procedure step completion. If an off-nominal condition occurs during procedure execution, PPL Loader notifies CRONUS through popup messages, allowing CRONUS to examine the situation and choose an option of how PPL loader should proceed with the procedure. The use of PPL Loader to perform frequent, routine PPL uplinks offloads CRONUS to better monitor two ISS systems. It also reduces procedure performance time and decreases risk of command errors. AutoORM identifies ISS communication outage periods and builds commands to lock, playback, and unlock ISS Operations Recorder files. Operation Recorder files are circular buffer files of continually recorded ISS telemetry data. Sections of these files can be locked from further writing, be played back to capture telemetry data that occurred during an ISS loss of signal (LOS) period, and then be unlocked for future recording use. Downlinked Operation Recorder files are used by mission support teams for data analysis, especially if failures occur during LOS. The commands to lock, playback, and unlock Operations Recorder files are encompassed in three different operational procedures and contain multiple user-input fields. AutoORM provides different levels of automation for building and uplinking the commands to lock, playback, and unlock Operations Recorder files. In its automatic mode, AutoORM automatically detects ISS LOS periods, then generates and uplinks the commands to lock, playback, and unlock Operations Recorder files when MCC regains signal with ISS. AutoORM also features semi-autonomous and manual modes which integrate CRONUS more into the command verification and uplink process. AutoORMs ability to automatically detect ISS LOS periods and build the necessary commands to preserve, playback, and release recorded telemetry data greatly offloads CRONUS to perform more high-level cognitive tasks, such as mission planning and anomaly troubleshooting. Additionally, since Operations Recorder commands contain numerical time input fields which are tedious for a human to manually build, AutoORM's ability to automatically build commands reduces operational command errors. PPL Loader and AutoORM demonstrate principles of semi-autonomous operational tools that will benefit future space mission operations. Both tools employ different levels of automation to perform simple and routine procedures, thereby offloading human operators to perform higher-level cognitive tasks. Because both tools provide procedure execution status and highlight off-nominal indications, the flight controller is able to intervene during procedure execution if needed. Semi-autonomous tools and systems that can perform routine procedures, yet keep human operators informed of execution, will be essential in future long-duration missions where the onboard crew will be solely responsible for spacecraft monitoring and control.
Multipole correction of atomic monopole models of molecular charge distribution. I. Peptides
NASA Technical Reports Server (NTRS)
Sokalski, W. A.; Keller, D. A.; Ornstein, R. L.; Rein, R.
1993-01-01
The defects in atomic monopole models of molecular charge distribution have been analyzed for several model-blocked peptides and compared with accurate quantum chemical values. The results indicate that the angular characteristics of the molecular electrostatic potential around functional groups capable of forming hydrogen bonds can be considerably distorted within various models relying upon isotropic atomic charges only. It is shown that these defects can be corrected by augmenting the atomic point charge models by cumulative atomic multipole moments (CAMMs). Alternatively, sets of off-center atomic point charges could be automatically derived from respective multipoles, providing approximately equivalent corrections. For the first time, correlated atomic multipoles have been calculated for N-acetyl, N'-methylamide-blocked derivatives of glycine, alanine, cysteine, threonine, leucine, lysine, and serine using the MP2 method. The role of the correlation effects in the peptide molecular charge distribution are discussed.
An inexpensive economical solar heating system for homes
NASA Technical Reports Server (NTRS)
Allred, J. W.; Shinn, J. M., Jr.; Kirby, C. E.; Barringer, S. R.
1976-01-01
A low-cost solar home heating system to supplement existing warm-air heating systems is described. The report is written in three parts: (1) a brief background on solar heating, (2) experience with a demonstration system, and (3) information for the homeowner who wishes to construct such a system. Instructions are given for a solar heating installation in which the homeowner supplies all labor necessary to install off-the-shelf components estimated to cost $2,000. These components, which include solar collector, heat exchanger, water pump, storage tank, piping, and controls to make the system completely automatic, are available at local lumber yards, hardware stores, and plumbing supply stores, and are relatively simple to install. Manufacturers and prices of each component used and a rough cost analysis based on these prices are included. This report also gives performance data obtained from a demonstration system which was built and tested at the Langley Research Center.
VSTOL Systems Research Aircraft (VSRA) Harrier
NASA Technical Reports Server (NTRS)
1994-01-01
NASA's Ames Research Center has developed and is testing a new integrated flight and propulsion control system that will help pilots land aircraft in adverse weather conditions and in small confined ares (such as, on a small ship or flight deck). The system is being tested in the V/STOL (Vertical/Short Takeoff and Landing) Systems research Aircraft (VSRA), which is a modified version of the U.S. Marine Corps's AV-8B Harrier jet fighter, which can take off and land vertically. The new automated flight control system features both head-up and panel-mounted computer displays and also automatically integrates control of the aircraft's thrust and thrust vector control, thereby reducing the pilot's workload and help stabilize the aircraft for landing. Visiting pilots will be encouraged to test the new system and provide formal evaluation flights data and feedback. An actual flight test and the display panel of control system are shown in this video.
STS-56 ESC Earth observation of New York City at night
NASA Technical Reports Server (NTRS)
1993-01-01
STS-56 electronic still camera (ESC) Earth observation image shows New York City at night as recorded on the 64th orbit of Discovery, Orbiter Vehicle (OV) 103. The image was recorded with an image intensifier on the Hand-held, Earth-oriented, Real-time, Cooperative, User-friendly, Location-targeting and Environmental System (HERCULES). HERCULES is a device that makes it simple for shuttle crewmembers to take pictures of Earth as they merely point a modified 35mm camera and shoot any interesting feature, whose latitude and longitude are automatically determined in real-time. Center coordinates on this image are 40.665 degrees north latitude and 74.048 degrees west longitude. (1/60 second exposure). Digital file name is ESC04034.IMG.
Automatically Log Off Upon Disappearance of Facial Image
2005-03-01
log off a PC when the user’s face disappears for an adjustable time interval. Among the fundamental technologies of biometrics, facial recognition is... facial recognition products. In this report, a brief overview of face detection technologies is provided. The particular neural network-based face...ensure that the user logging onto the system is the same person. Among the fundamental technologies of biometrics, facial recognition is the only
Automated coronary artery calcification detection on low-dose chest CT images
NASA Astrophysics Data System (ADS)
Xie, Yiting; Cham, Matthew D.; Henschke, Claudia; Yankelevitz, David; Reeves, Anthony P.
2014-03-01
Coronary artery calcification (CAC) measurement from low-dose CT images can be used to assess the risk of coronary artery disease. A fully automatic algorithm to detect and measure CAC from low-dose non-contrast, non-ECG-gated chest CT scans is presented. Based on the automatically detected CAC, the Agatston score (AS), mass score and volume score were computed. These were compared with scores obtained manually from standard-dose ECG-gated scans and low-dose un-gated scans of the same patient. The automatic algorithm segments the heart region based on other pre-segmented organs to provide a coronary region mask. The mitral valve and aortic valve calcification is identified and excluded. All remaining voxels greater than 180HU within the mask region are considered as CAC candidates. The heart segmentation algorithm was evaluated on 400 non-contrast cases with both low-dose and regular dose CT scans. By visual inspection, 371 (92.8%) of the segmentations were acceptable. The automated CAC detection algorithm was evaluated on 41 low-dose non-contrast CT scans. Manual markings were performed on both low-dose and standard-dose scans for these cases. Using linear regression, the correlation of the automatic AS with the standard-dose manual scores was 0.86; with the low-dose manual scores the correlation was 0.91. Standard risk categories were also computed. The automated method risk category agreed with manual markings of gated scans for 24 cases while 15 cases were 1 category off. For low-dose scans, the automatic method agreed with 33 cases while 7 cases were 1 category off.
Lushaj, Entela B; Schreiner, Athanasia; Jonuzi, Besa; Badami, Abbasali; DeOliveira, Nilto; Lozonschi, Lucian
2016-05-17
We retrospectively assessed the outcomes after coronary revascularization at a single Veterans Affairs Medical Center when a strategy of assigning higher risk patients to off-pump coronary artery bypass grafting (CABG) was employed. Over a 5 year period all consecutive patients that underwent CABG at our VA Medical Center were assigned to a surgeon who either performs the CABG exclusively off-pump or to one who performed the CABG on-pump. The higher risk patients were assigned preferentially for off-pump revascularization. VASQIP (VA Hospitals Surgical Quality Improvement Program) data between 10/2007 and 12/2012 were retrospectively reviewed at our VA Medical Center and the short term outcomes were assessed. A total of 252 consecutive patients underwent off-pump CABG (n = 170) and on-pump CABG (n = 82). There were significantly more patients with low LVEF (<45 %; p = 0.008) and cerebrovascular disease in the off-pump group (p = 0.024). The number of patients smoking at the time of surgery was significantly higher in the off-pump group (p = 0.002) as well. The 30-day composite morbidity and mortality was 6 % for all CABG patients and significantly lower with off-pump vs. on-pump CABG (3.5 % vs. 11 %; p = 0.019). There were no conversions from off-pump to on-pump surgery. A selective strategy to direct higher risk patients towards an off-pump revascularization yielded favorable outcomes in an unselected veteran population treated at a single VA Medical Center over a 5 year period.
Automated Generation of Fault Management Artifacts from a Simple System Model
NASA Technical Reports Server (NTRS)
Kennedy, Andrew K.; Day, John C.
2013-01-01
Our understanding of off-nominal behavior - failure modes and fault propagation - in complex systems is often based purely on engineering intuition; specific cases are assessed in an ad hoc fashion as a (fallible) fault management engineer sees fit. This work is an attempt to provide a more rigorous approach to this understanding and assessment by automating the creation of a fault management artifact, the Failure Modes and Effects Analysis (FMEA) through querying a representation of the system in a SysML model. This work builds off the previous development of an off-nominal behavior model for the upcoming Soil Moisture Active-Passive (SMAP) mission at the Jet Propulsion Laboratory. We further developed the previous system model to more fully incorporate the ideas of State Analysis, and it was restructured in an organizational hierarchy that models the system as layers of control systems while also incorporating the concept of "design authority". We present software that was developed to traverse the elements and relationships in this model to automatically construct an FMEA spreadsheet. We further discuss extending this model to automatically generate other typical fault management artifacts, such as Fault Trees, to efficiently portray system behavior, and depend less on the intuition of fault management engineers to ensure complete examination of off-nominal behavior.
9 CFR 307.7 - Safety requirements for electrical stimulating (EST) equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... manual stimulation or before the carcass chain is started in an automatic system. (c) Operation—(1... personnel, the electricity supplied to the stimulating surfaces shall be locked-off when cleaning...
Design of autonomous sensor nodes for remote soil monitoring in tropical banana plantation
NASA Astrophysics Data System (ADS)
Tiausas, Francis Jerome G.; Co, Jerelyn; Macalinao, Marc Joseph M.; Guico, Maria Leonora; Monje, Jose Claro; Oppus, Carlos
2017-09-01
Determining the effect of Fusarium oxysporum f. sp. cubense Tropical Race 4 on various soil parameters is essential in modeling and predicting its occurrence in banana plantations. One way to fulfill this is through a sensor network that will continuously and automatically monitor environmental conditions at suspect locations for an extended period of time. A wireless sensor network was developed specifically for this purpose. This sensor network is capable of measuring soil acidity, moisture, temperature, and conductivity. The designed prototype made use of off-the-shelf Parrot Flower Power soil sensor, pH sensor, Bluno Beetle, battery, and 3D-printed materials, catering specifically to the conditions of tropical banana plantations with consideration for sensor node size, communication, and power. Sensor nodes were tested on both simulated tropical environments and on an actual banana plantation in San Jose, General Santos City, Philippines. Challenges were resolved through iterative design and development of prototypes. Several tests including temperature and weather resilience, and structural stress tests were done to validate the design. Findings showed that the WSN nodes developed for this purpose are resilient to high tropical temperatures for up to 12 hours of continuous exposure, are able to withstand compressive forces of up to 8880.6 N, and can reliably collect data automatically from the area 47.96% of the time at an hourly frequency under actual field conditions.
Automatic Speed Control and Turning ON/OFF for Smart Fan by Temperature and Ultrasonic Sensor
NASA Astrophysics Data System (ADS)
Kanchanasatian, Keeratiburt
2018-03-01
When it is hot, using a fan is an inexpensive choice compared to spending more on using an air conditioner especially in some areas where high temperature is naturally normal. Some problems, nonetheless, arisen such as users forget to turn off when being away, some people might get a feeling of annoyance and perhaps frustration when getting up from the seat in order to adjust the speed. These result in a rise of electricity bill from leaving the fan on when it is not in use and it may cause disasters, fire for example, when the motor get heated up. A prototype of smart fan was built in this research using ESP8266 as a microcontroller, DHT22 and HC-SR04 are used to measure temperature for speed control and detect the user for automatic on/off respectively. A group of participants used the prototype and they were interviewed to give some feedbacks, comments, and suggestions from the experiences after using it. The results show that they were satisfied from the automation; it gave the sense of staying in a modern house with an automatic wind blower. It also assisted to reduce energy consumption according to target group. Some users stated that the environment and atmosphere in the room was not too hot because the fan was working in the background. This has shown that the prototype significantly gave the participants a feeling of relaxation and comfortability and also was a part of energy and cost reduction.
Thalamic deep brain stimulation decelerates automatic lexical activation.
Ehlen, Felicitas; Vonberg, Isabelle; Tiedt, Hannes O; Horn, Andreas; Fromm, Ortwin; Kühn, Andrea A; Klostermann, Fabian
2017-02-01
Deep Brain Stimulation (DBS) of the thalamic ventral intermediate nucleus (VIM) is a therapeutic option for patients with essential tremor. Despite a generally low risk of side effects, declines in verbal fluency (VF) have previously been reported. We aimed to specify effects of VIM-DBS on major cognitive operations needed for VF task performance, represented by clusters and switches. Clusters are word production spurts, thought to arise from automatic activation of associated information pertaining to a given lexical field. Switches are slow word-to-word transitions, presumed to indicate controlled operations for stepping from one lexical field to another. Thirteen essential tremor patients with VIM-DBS performed verbal fluency tasks in their VIM-DBS ON and OFF conditions. Clusters and switches were formally defined by mathematical criteria. All results were compared to those of fifteen healthy control subjects, and significant OFF-ON-change scores were correlated to stimulation parameters. Patients produced fewer words than healthy controls. DBS ON compared to DBS OFF aggravated this deficit by prolonging the intervals between words within clusters, whereas switches remained unaffected. This stimulation effect correlated with more anterior electrode positions. VIM-DBS seems to influence word output dynamics during verbal fluency tasks on the level of word clustering. This suggests a perturbation of automatic lexical co-activation by thalamic stimulation, particularly if delivered relatively anteriorly. The findings are discussed in the context of the hypothesized role of the thalamus in lexical processing. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Morton, Daniel R.
Modern image guided radiation therapy involves the use of an isocentrically mounted imaging system to take radiographs of a patient's position before the start of each treatment. Image guidance helps to minimize errors associated with a patients setup, but the radiation dose received by patients from imaging must be managed to ensure no additional risks. The Varian On-Board Imager (OBI) (Varian Medical Systems, Inc., Palo Alto, CA) does not have an automatic exposure control system and therefore requires exposure factors to be manually selected. Without patient specific exposure factors, images may become saturated and require multiple unnecessary exposures. A software based automatic exposure control system has been developed to predict optimal, patient specific exposure factors. The OBI system was modelled in terms of the x-ray tube output and detector response in order to calculate the level of detector saturation for any exposure situation. Digitally reconstructed radiographs are produced via ray-tracing through the patients' volumetric datasets that are acquired for treatment planning. The ray-trace determines the attenuation of the patient and subsequent x-ray spectra incident on the imaging detector. The resulting spectra are used in the detector response model to determine the exposure levels required to minimize detector saturation. Images calculated for various phantoms showed good agreement with the images that were acquired on the OBI. Overall, regions of detector saturation were accurately predicted and the detector response for non-saturated regions in images of an anthropomorphic phantom were calculated to generally be within 5 to 10 % of the measured values. Calculations were performed on patient data and found similar results as the phantom images, with the calculated images being able to determine detector saturation with close agreement to images that were acquired during treatment. Overall, it was shown that the system model and calculation method could potentially be used to predict patients' exposure factors before their treatment begins, thus preventing the need for multiple exposures.
ERIC Educational Resources Information Center
Chung, Yi-Chieh; Cannella-Malone, Helen I.
2010-01-01
This study examined the effects of presession exposure to attention, response blocking, attention with response blocking, and noninteraction conditions on subsequent engagement in automatically maintained challenging behavior and correct responding in four individuals with significant intellectual disabilities. Following a functional analysis, the…
Kim, Sung-Chul; Lee, Hae-Kag; Lee, Yang-Sub; Cho, Jae-Hwan
2015-01-01
We found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.
Automatic Car Identification - an Evaluation
DOT National Transportation Integrated Search
1972-03-01
In response to a Federal Railroad Administration request, the Transportation Systems Center evaluated the Automatic Car Identification System (ACI) used on the nation's railroads. The ACI scanner was found to be adequate for reliable data output whil...
49 CFR 192.171 - Compressor stations: Additional safety equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... operates with pressure gas injection must be equipped so that stoppage of the engine automatically shuts off the fuel and vents the engine distribution manifold. (e) Each muffler for a gas engine in a...
49 CFR 192.171 - Compressor stations: Additional safety equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... operates with pressure gas injection must be equipped so that stoppage of the engine automatically shuts off the fuel and vents the engine distribution manifold. (e) Each muffler for a gas engine in a...
Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C
2015-06-01
Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.
Breska, Assaf; Deouell, Leon Y
2016-07-06
Environmental rhythms potently drive predictive resource allocation in time, typically leading to perceptual and motor benefits for on-beat, relative to off-beat, times, even if the rhythmic stream is not intentionally used. In two human EEG experiments, we investigated the behavioral and electrophysiological expressions of using rhythms to direct resources away from on-beat times. This allowed us to distinguish goal-directed attention from the automatic capture of attention by rhythms. The following three conditions were compared: (1) a rhythmic stream with targets appearing frequently at a fixed off-beat position; (2) a rhythmic stream with targets appearing frequently at on-beat times; and (3) a nonrhythmic stream with matched target intervals. Shifting resources away from on-beat times was expressed in the slowing of responses to on-beat targets, but not in the facilitation of off-beat targets. The shifting of resources was accompanied by anticipatory adjustment of the contingent negative variation (CNV) buildup toward the expected off-beat time. In the second experiment, off-beat times were jittered, resulting in a similar CNV adjustment and also in preparatory amplitude reduction of beta-band activity. Thus, the CNV and beta activity track the relevance of time points and not the rhythm, given sufficient incentive. Furthermore, the effects of task relevance (appearing in a task-relevant vs irrelevant time) and rhythm (appearing on beat vs off beat) had additive behavioral effects and also dissociable neural manifestations in target-evoked activity: rhythm affected the target response as early as the P1 component, while relevance affected only the later N2 and P3. Thus, these two factors operate by distinct mechanisms. Rhythmic streams are widespread in our environment, and are typically conceptualized as automatic, bottom-up resource attractors to on-beat times-preparatory neural activity peaks at rhythm-on-beat times and behavioral benefits are seen to on-beat compared with off-beat targets. We show that this behavioral benefit is reversed when targets are more frequent at off-beat compared with on-beat times, and that preparatory neural activity, previously thought to be driven by the rhythm to on-beat times, is adjusted toward off-beat times. Furthermore, the effect of this relevance-based shifting on target-evoked brain activity was dissociable from the automatic effect of rhythms. Thus, rhythms can act as cues for flexible resource allocation according to the goal relevance of each time point, instead of being obligatory resource attractors. Copyright © 2016 the authors 0270-6474/16/367154-13$15.00/0.
Lim, Jiyeon; Park, Eun-Ah; Lee, Whal; Shim, Hackjoon; Chung, Jin Wook
2015-06-01
To assess the image quality and radiation exposure of 320-row area detector computed tomography (320-ADCT) coronary angiography with optimal tube voltage selection with the guidance of an automatic exposure control system in comparison with a body mass index (BMI)-adapted protocol. Twenty-two patients (study group) underwent 320-ADCT coronary angiography using an automatic exposure control system with the target standard deviation value of 33 as the image quality index and the lowest possible tube voltage. For comparison, a sex- and BMI-matched group (control group, n = 22) using a BMI-adapted protocol was established. Images of both groups were reconstructed by an iterative reconstruction algorithm. For objective evaluation of the image quality, image noise, vessel density, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were measured. Two blinded readers then subjectively graded the image quality using a four-point scale (1: nondiagnostic to 4: excellent). Radiation exposure was also measured. Although the study group tended to show higher image noise (14.1 ± 3.6 vs. 9.3 ± 2.2 HU, P = 0.111) and higher vessel density (665.5 ± 161 vs. 498 ± 143 HU, P = 0.430) than the control group, the differences were not significant. There was no significant difference between the two groups for SNR (52.5 ± 19.2 vs. 60.6 ± 21.8, P = 0.729), CNR (57.0 ± 19.8 vs. 67.8 ± 23.3, P = 0.531), or subjective image quality scores (3.47 ± 0.55 vs. 3.59 ± 0.56, P = 0.960). However, radiation exposure was significantly reduced by 42 % in the study group (1.9 ± 0.8 vs. 3.6 ± 0.4 mSv, P = 0.003). Optimal tube voltage selection with the guidance of an automatic exposure control system in 320-ADCT coronary angiography allows substantial radiation reduction without significant impairment of image quality, compared to the results obtained using a BMI-based protocol.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyer, W.B.
1979-09-01
This report describes both the hardware and software components of an automatic calibration and signal system (Autocal) for the data acquisition system for the Sandia particle beam fusion research accelerators Hydra, Proto I, and Proto II. The Autocal hardware consists of off-the-shelf commercial equipment. The various hardware components, special modifications and overall system configuration are described. Special software has been developed to support the Autocal hardware. Software operation and maintenance are described.
USSR Report, Kommunist, No. 13, September 1986.
1987-01-07
all-union) program for specialization of NPO and industrial enterprises and their scientific research institutes and design bureaus could play a major...machine tools with numerical programming (ChPU), processing centers, automatic machines and groups of automatic machines controlled by computers, and...automatic lines, computer- controlled groups of equipment, comprehensively automated shops and sections) is the most important feature of high technical
NASA Astrophysics Data System (ADS)
De Matteis, M.; De Blasi, M.; Vallicelli, E. A.; Zannoni, M.; Gervasi, M.; Bau, A.; Passerini, A.; Baschirotto, A.
2017-02-01
This paper presents the design and the experimental results of a CMOS Automatic Control System (ACS) for the biasing of High-Electron-Mobility-Transistors (HEMT). The ACS is the first low-power mixed-signal Application-Specified-Integrated-Circuit (ASIC) able to automatically set and regulate the operating point of an off-chip 6 HEMT Low-Noise-Amplifiers (LNAs), hence it composes a two-chip system (the ACS+LNAs) to be used in the Large Scale Polarization Explorer (LSPE) stratospheric balloon for Cosmic Microwave Background (CMB) signal observation. The hereby presented ACS ASIC provides a reliable instrumentation for gradual and very stable LNAs characterization, switching-on, and operating point (<4 mV accuracy). Moreover, it simplifies the electronic instrumentation needed for biasing the LNAs, since it replaces several off-the-shelf and digital programmable device components. The ASIC prototype has been implemented in a CMOS 0.35 μ m technology (12 mm2 area occupancy). It operates at 4 kHz clock frequency. The power consumption of one-channel ASIC (biasing one LNA) is 3.6 mW, whereas 30 mW are consumed by a single LNA device.
De Matteis, M; De Blasi, M; Vallicelli, E A; Zannoni, M; Gervasi, M; Bau, A; Passerini, A; Baschirotto, A
2017-02-01
This paper presents the design and the experimental results of a CMOS Automatic Control System (ACS) for the biasing of High-Electron-Mobility-Transistors (HEMT). The ACS is the first low-power mixed-signal Application-Specified-Integrated-Circuit (ASIC) able to automatically set and regulate the operating point of an off-chip 6 HEMT Low-Noise-Amplifiers (LNAs), hence it composes a two-chip system (the ACS+LNAs) to be used in the Large Scale Polarization Explorer (LSPE) stratospheric balloon for Cosmic Microwave Background (CMB) signal observation. The hereby presented ACS ASIC provides a reliable instrumentation for gradual and very stable LNAs characterization, switching-on, and operating point (<4 mV accuracy). Moreover, it simplifies the electronic instrumentation needed for biasing the LNAs, since it replaces several off-the-shelf and digital programmable device components. The ASIC prototype has been implemented in a CMOS 0.35 μm technology (12 mm 2 area occupancy). It operates at 4 kHz clock frequency. The power consumption of one-channel ASIC (biasing one LNA) is 3.6 mW, whereas 30 mW are consumed by a single LNA device.
Hippocratic ideal, Faustian bargain and Damocles' sword: erosion of patient autonomy in obstetrics.
Rybak, E A
2009-11-01
Respect for patient autonomy remains a foundational principle guiding the ethical practice of medicine-a mission first articulated by Hippocrates. Damocles, another figure from ancient Greece, provides a useful parable for describing performance under distress: Damocles loses his desire for opulence and power when he notices a sword dangling precariously above his head. Contemporary obstetricians deciding whether to forestall or impose major abdominal surgery on parturients entrusted to their care struggle valiantly in the chasm dividing Hippocratic idealism from the economic realism driven by the medicolegal sword of Damocles. Given the inherent risk of unforeseeable and unsalvageable fetal catastrophe during labor and vaginal delivery, and the often unsubstantiated, yet automatic, allegation of negligence that follows a labor-associated adversity, obstetricians-and their liability insurance carriers-have recalibrated obstetric practice in alignment with the increasingly risk-averse preferences of most patients. Indeed, less intrapartum risk for patients and less corresponding medicolegal exposure for obstetricians help explain the rising cesarean delivery rate and, more importantly, the steady disappearance of higher-risk interventions such as vaginal birth after cesarean (VBAC). Is this increasing reluctance to offer VBAC supervision ethically defensible? This paper argues that it is. Fiduciary professionalism mandates physician self-sacrifice, not self-destruction; a VBAC gone awry without negligence or substandard care may, nevertheless, render future affordable liability coverage unattainable. Yet, the unavailability of VBAC infringes on the autonomy of women who want to assume the intrapartum risks of a VBAC in lieu of a repeat cesarean delivery. The proposed solution is the regionalization of VBAC care provision in designated medical centers and/or the implementation of binding arbitration in an ethical trade-off to enhance patient autonomy regarding the preferred mode of delivery despite parallel constraint on legal options.
Evaluation of the Monitor-CTA Automatic Vehicle Monitoring System
DOT National Transportation Integrated Search
1974-03-01
In June 1972 the Urban Mass Transportation Administration requested that the Transportation System Center of DOT perform an evaluation of the CTA (Chicago Transit Authority) Monitor-Automatic Vehicle Monitor (AVM) system. TSC planned the overall eval...
Pediatric Eye Screening Instrumentation
NASA Astrophysics Data System (ADS)
Chen, Ying-Ling; Lewis, J. W. L.
2001-11-01
Computational evaluations are presented for binocular eye screening using the off-axis digital retinascope. The retinascope, such as the iScreen digital screening system, has been employed to perform pediatric binocular screening using a flash lamp and single-shot camera recording. The digital images are transferred electronically to a reading center for analysis. The method has been shown to detect refractive error, amblyopia, anisocoria, and ptosis. This computational work improves the performance of the system and forms the basis for automated data analysis. For this purpose, variouis published eye models are evaluated with simulated retinascope images. Two to ten million rays are traced in each image calculation. The poster will present the simulation results for a range of eye conditions of refractive error of -20 to +20 diopters with 0.5- to-1 diopter resolution, pupil size of 3 to 8 mm diameter (1-mm increment), and staring angle of 2 to 12 degree (2-degree increment). The variation of the results with the system conditions such as the off-axis distance of light source and the shutter size of camera are also evaluated. The quantitative analysis for each eye’s and system’s condition is then performed to obtain parameters for automatic reading. The summary of the system performance is given and performance-enhancement design modifications are presented.
Merchant, Nathan D; Witt, Matthew J; Blondel, Philippe; Godley, Brendan J; Smith, George H
2012-07-01
Underwater noise from shipping is a growing presence throughout the world's oceans, and may be subjecting marine fauna to chronic noise exposure with potentially severe long-term consequences. The coincidence of dense shipping activity and sensitive marine ecosystems in coastal environments is of particular concern, and noise assessment methodologies which describe the high temporal variability of sound exposure in these areas are needed. We present a method of characterising sound exposure from shipping using continuous passive acoustic monitoring combined with Automatic Identification System (AIS) shipping data. The method is applied to data recorded in Falmouth Bay, UK. Absolute and relative levels of intermittent ship noise contributions to the 24-h sound exposure level are determined using an adaptive threshold, and the spatial distribution of potential ship sources is then analysed using AIS data. This technique can be used to prioritize shipping noise mitigation strategies in coastal marine environments. Copyright © 2012 Elsevier Ltd. All rights reserved.
Impact of the lay-off length on +Gz tolerance.
Mikuliszyn, Romuald; Kowalski, Wieslaw; Kowalczuk, Krzysztof
2002-07-01
There are many factors affecting pilots' +Gz-tolerance. Recently, attention of the aviation community has been focused on lay-off and it's impact on +Gz-tolerance. Pilots of the Polish Air Force (PAF) have dealt with that problem for several years now. The aim of the study was to provide insight on how lay-off periods with different duration impact +Gz-tolerance. 95 male jet pilots from the PAF participated in the study. Every one had at least two weeks lay-off period (non-medical reasons). Subjects were divided into four groups according to the length of lay-off period (2-4 weeks; 5-13 weeks; 14-26 weeks; 27-154 weeks), All pilots were subjected to a centrifuge exposure in GOR (0.1 G/s) or ROR (1.0 G/s) profiles, depending on the pre-lay-off exposure. Post-lay-off exposures were carried out directly after lay-off. 18 jet pilots without any lay-off constituted the control group. The difference between pre- and post-lay-off G-tolerance limit (-0,93 +/- 0,53) was statistically significant (p<0.01) only for one group, where lay-off period ranged between two and four weeks. No statistically significant differences were found where influence of other factors like total and yearly flight hours, heart rate gain (AHR) or physical activity measured as maximal oxygen intake were considered. 2-4 weeks of lay-off period decreases +Gz tolerance is statistically significant manner. Subsequent increase of lay-off period does not result in mean tolerance changes for group, however in certain individuals critical decrement of +Gz tolerance occurs. Total and last year flying hours, physical fitness does not modify impact of lay-off period on +Gz tolerance.
Monitoring the Black Hole Binary GRS 1758-258 with INTEGRAL and RXTE
NASA Technical Reports Server (NTRS)
Pottschmidt, Katja; Chernyakova, Masha; Lubinski, Piotr; Migliari, Simone; Smith, David M.; Zdziarski, Andrzej A.; Tomsick, John A.; Bezayiff, N.; Kreykenbohm, Ingo; Kretschmar, Peter;
2008-01-01
The microquasar GRS 1758-258 is one of only three persistent black hole binaries that spend most of their time in the hard spectral state, the other two being Cyg X-l and 1E 1741.7-2942. It therefore provides the rare opportunity for an extensive long term study of this important black hole state which is associated with strong variability and radio jet emission. INTEGRAL has been monitoring the source since the first Galactic Center Deep Exposure season in spring 2003 during two 2-3 months long Galactic Center viewing epochs each year, amounting to 11 epochs including spring of 2008. With the exception of the last epoch quasi-simultaneous RXTE monitoring observations are available as well. Here we present an analysis of the epoch averaged broad band spectra which display considerable long term variability, most notably the occurrence of two soft/off states, extreme examples for the hysteretic behavior of black hole binaries. The hard source spectrum and long exposures allow us to extend the analysis for several epochs to approximately 800 keV using PICsIT data and address the question of the presence of a non-thermal Comptonization component.
Hankey, Steve; Lindsey, Greg; Marshall, Julian D
2017-04-01
Providing infrastructure and land uses to encourage active travel (i.e., bicycling and walking) are promising strategies for designing health-promoting cities. Population-level exposure to air pollution during active travel is understudied. Our goals were a ) to investigate population-level patterns in exposure during active travel, based on spatial estimates of bicycle traffic, pedestrian traffic, and particulate concentrations; and b ) to assess how those exposure patterns are associated with the built environment. We employed facility-demand models (active travel) and land use regression models (particulate concentrations) to estimate block-level ( n = 13,604) exposure during rush-hour (1600-1800 hours) in Minneapolis, Minnesota. We used the model-derived estimates to identify land use patterns and characteristics of the street network that are health promoting. We also assessed how exposure is correlated with indicators of health disparities (e.g., household income, proportion of nonwhite residents). Our work uses population-level rates of active travel (i.e., traffic flows) rather than the probability of walking or biking (i.e., "walkability" or "bikeability") to assess exposure. Active travel often occurs on high-traffic streets or near activity centers where particulate concentrations are highest (i.e., 20-42% of active travel occurs on blocks with high population-level exposure). Only 2-3% of blocks (3-8% of total active travel) are "sweet spots" (i.e., high active travel, low particulate concentrations); sweet spots are located a ) near but slightly removed from the city-center or b ) on off-street trails. We identified 1,721 blocks (~ 20% of local roads) where shifting active travel from high-traffic roads to adjacent low-traffic roads would reduce exposure by ~ 15%. Active travel is correlated with population density, land use mix, open space, and retail area; particulate concentrations were mostly unchanged with land use. Public health officials and urban planners may use our findings to promote healthy transportation choices. When designing health-promoting cities, benefits (physical activity) as well as hazards (air pollution) should be evaluated.
Lessons learned from the introduction of autonomous monitoring to the EUVE science operations center
NASA Technical Reports Server (NTRS)
Lewis, M.; Girouard, F.; Kronberg, F.; Ringrose, P.; Abedini, A.; Biroscak, D.; Morgan, T.; Malina, R. F.
1995-01-01
The University of California at Berkeley's (UCB) Center for Extreme Ultraviolet Astrophysics (CEA), in conjunction with NASA's Ames Research Center (ARC), has implemented an autonomous monitoring system in the Extreme Ultraviolet Explorer (EUVE) science operations center (ESOC). The implementation was driven by a need to reduce operations costs and has allowed the ESOC to move from continuous, three-shift, human-tended monitoring of the science payload to a one-shift operation in which the off shifts are monitored by an autonomous anomaly detection system. This system includes Eworks, an artificial intelligence (AI) payload telemetry monitoring package based on RTworks, and Epage, an automatic paging system to notify ESOC personnel of detected anomalies. In this age of shrinking NASA budgets, the lessons learned on the EUVE project are useful to other NASA missions looking for ways to reduce their operations budgets. The process of knowledge capture, from the payload controllers for implementation in an expert system, is directly applicable to any mission considering a transition to autonomous monitoring in their control center. The collaboration with ARC demonstrates how a project with limited programming resources can expand the breadth of its goals without incurring the high cost of hiring additional, dedicated programmers. This dispersal of expertise across NASA centers allows future missions to easily access experts for collaborative efforts of their own. Even the criterion used to choose an expert system has widespread impacts on the implementation, including the completion time and the final cost. In this paper we discuss, from inception to completion, the areas where our experiences in moving from three shifts to one shift may offer insights for other NASA missions.
Pérez-Díaz, Francisco; Díaz, Estrella; Sánchez, Natividad; Vargas, Juan Pedro; Pearce, John M; López, Juan Carlos
2017-01-01
Recent studies support the idea that stimulus processing in latent inhibition can vary during the course of preexposure. Controlled attentional mechanisms are said to be important in the early stages of preexposure, while in later stages animals adopt automatic processing of the stimulus to be used for conditioning. Given this distinction, it is possible that both types of processing are governed by different neural systems, affecting differentially the retrieval of information about the stimulus. In the present study we tested if a lesion to the dorso-lateral striatum or to the medial prefrontal cortex has a selective effect on exposure to the future conditioned stimulus (CS). With this aim, animals received different amounts of exposure to the future CS. The results showed that a lesion to the medial prefrontal cortex enhanced latent inhibition in animals receiving limited preexposure to the CS, but had no effect in animals receiving extended preexposure to the CS. The lesion of the dorso-lateral striatum produced a decrease in latent inhibition, but only in animals with an extended exposure to the future conditioned stimulus. These results suggest that the dorsal striatum and medial prefrontal cortex play essential roles in controlled and automatic processes. Automatic attentional processes appear to be impaired by a lesion to the dorso-lateral striatum and facilitated by a lesion to the prefrontal cortex.
Automatic mimicry reactions as related to differences in emotional empathy.
Sonnby-Borgström, Marianne
2002-12-01
The hypotheses of this investigation were derived by conceiving of automatic mimicking as a component of emotional empathy. Differences between subjects high and low in emotional empathy were investigated. The parameters compared were facial mimicry reactions, as represented by electromyographic (EMG) activity when subjects were exposed to pictures of angry or happy faces, and the degree of correspondence between subjects' facial EMG reactions and their self-reported feelings. The comparisons were made at different stimulus exposure times in order to elicit reactions at different levels of information processing. The high-empathy subjects were found to have a higher degree of mimicking behavior than the low-empathy subjects, a difference that emerged at short exposure times (17-40 ms) that represented automatic reactions. The low-empathy subjects tended already at short exposure times (17-40 ms) to show inverse zygomaticus muscle reactions, namely "smiling" when exposed to an angry face. The high-empathy group was characterized by a significantly higher correspondence between facial expressions and self-reported feelings. No differences were found between the high- and low-empathy subjects in their verbally reported feelings when presented a happy or an angry face. Thus, the differences between the groups in emotional empathy appeared to be related to differences in automatic somatic reactions to facial stimuli rather than to differences in their conscious interpretation of the emotional situation.
Pérez-Díaz, Francisco; Díaz, Estrella; Sánchez, Natividad; Vargas, Juan Pedro; Pearce, John M.
2017-01-01
Recent studies support the idea that stimulus processing in latent inhibition can vary during the course of preexposure. Controlled attentional mechanisms are said to be important in the early stages of preexposure, while in later stages animals adopt automatic processing of the stimulus to be used for conditioning. Given this distinction, it is possible that both types of processing are governed by different neural systems, affecting differentially the retrieval of information about the stimulus. In the present study we tested if a lesion to the dorso-lateral striatum or to the medial prefrontal cortex has a selective effect on exposure to the future conditioned stimulus (CS). With this aim, animals received different amounts of exposure to the future CS. The results showed that a lesion to the medial prefrontal cortex enhanced latent inhibition in animals receiving limited preexposure to the CS, but had no effect in animals receiving extended preexposure to the CS. The lesion of the dorso-lateral striatum produced a decrease in latent inhibition, but only in animals with an extended exposure to the future conditioned stimulus. These results suggest that the dorsal striatum and medial prefrontal cortex play essential roles in controlled and automatic processes. Automatic attentional processes appear to be impaired by a lesion to the dorso-lateral striatum and facilitated by a lesion to the prefrontal cortex. PMID:29240804
University Counseling Center Off-Campus Referrals: An Exploratory Investigation
ERIC Educational Resources Information Center
Owen, Jesse; Devdas, Lavanya; Rodolfa, Emil
2007-01-01
University counseling centers (UCC) must rely on referrals to off-campus providers, due to limited staffing, severity of clients' issues, and ethical treatment considerations. In a mixed method design, this study found that 42% of clients were unsuccessful in connecting with an off-campus provider when referred by a university counseling center…
Electronic transitions in quantum dots and rings induced by inhomogeneous off-centered light beams.
Quinteiro, G F; Lucero, A O; Tamborenea, P I
2010-12-22
We theoretically investigate the effect of inhomogeneous light beams with (twisted light) and without (plane-wave light) orbital angular momentum on semiconductor-based nanostructures, when the symmetry axes of the beam and the nanostructure are displaced parallel to each other. Exact analytical results are obtained by expanding the off-centered light field in terms of the appropriate light modes centered around the nanostructure. We demonstrate how electronic transitions involving the transfer of different amounts of orbital angular momentum are switched on and off as a function of the separation between the axes of the beam and the system. In particular, we show that even off-centered plane-wave beams induce transitions such that the angular momenta of the initial and final states are different.
Wang, Zhen J.; Chen, Katherine S.; Gould, Robert; Coakley, Fergus V.; Fu, Yanjun; Yeh, Benjamin M.
2014-01-01
Objective To assess the effect of positive enteric contrast administration on automatic exposure control (AEC) CT radiation exposure in 1) a CT phantom, and 2) a retrospective review of patients. Materials and Methods We scanned a CT phantom containing simulated bowel that was sequentially filled with water and positive enteric contrast, and recorded the mean volume CT dose index (CTDIvol). We also identified 17 patients who had undergone 2 technically comparable CT scans of the abdomen and pelvis, one with positive enteric contrast and the other with oral water. Paired student t-tests were used to compare the mean CTDIvol between scans performed with and without positive enteric contrast. Both the phantom and patient CT scans were performed using AEC with a fixed noise index. Results The mean CTDIvol for the phantom with simulated bowel containing water and positive enteric contrast were 8.2 ± 0.2 mGy, and 8.7 ± 0.1 mGy (6.1% higher than water, p=0.02), respectively. The mean CTDIvol for patients scanned with oral water and with positive enteric contrast were 11.8mGy and 13.1mGy, respectively (p=0.003). This corresponded to a mean CTDIvol which was 11.0% higher (range: 0.0–20.7% higher) in scans with positive enteric contrast than those with oral water in patients. Conclusions When automatic exposure control is utilized for abdominopelvic CT, the radiation exposure, as measured by CTDIvol, is higher for scans performed with positive enteric contrast than those with oral water. PMID:21493028
García-Betances, Rebeca I; Huerta, Mónica K
2012-01-01
A comparative review is presented of available technologies suitable for automatic reading of patient identification bracelet tags. Existing technologies' backgrounds, characteristics, advantages and disadvantages, are described in relation to their possible use by public health care centers with budgetary limitations. A comparative assessment is presented of suitable automatic identification systems based on graphic codes, both one- (1D) and two-dimensional (2D), printed on labels, as well as those based on radio frequency identification (RFID) tags. The analysis looks at the tradeoffs of these technologies to provide guidance to hospital administrator looking to deploy patient identification technology. The results suggest that affordable automatic patient identification systems can be easily and inexpensively implemented using 2D code printed on low cost bracelet labels, which can then be read and automatically decoded by ordinary mobile smart phones. Because of mobile smart phones' present versatility and ubiquity, the implantation and operation of 2D code, and especially Quick Response® (QR) Code, technology emerges as a very attractive alternative to automate the patients' identification processes in low-budget situations.
García-Betances, Rebeca I.; Huerta, Mónica K.
2012-01-01
A comparative review is presented of available technologies suitable for automatic reading of patient identification bracelet tags. Existing technologies’ backgrounds, characteristics, advantages and disadvantages, are described in relation to their possible use by public health care centers with budgetary limitations. A comparative assessment is presented of suitable automatic identification systems based on graphic codes, both one- (1D) and two-dimensional (2D), printed on labels, as well as those based on radio frequency identification (RFID) tags. The analysis looks at the tradeoffs of these technologies to provide guidance to hospital administrator looking to deploy patient identification technology. The results suggest that affordable automatic patient identification systems can be easily and inexpensively implemented using 2D code printed on low cost bracelet labels, which can then be read and automatically decoded by ordinary mobile smart phones. Because of mobile smart phones’ present versatility and ubiquity, the implantation and operation of 2D code, and especially Quick Response® (QR) Code, technology emerges as a very attractive alternative to automate the patients’ identification processes in low-budget situations. PMID:23569629
Automatic and user-centric approaches to video summary evaluation
NASA Astrophysics Data System (ADS)
Taskiran, Cuneyt M.; Bentley, Frank
2007-01-01
Automatic video summarization has become an active research topic in content-based video processing. However, not much emphasis has been placed on developing rigorous summary evaluation methods and developing summarization systems based on a clear understanding of user needs, obtained through user centered design. In this paper we address these two topics and propose an automatic video summary evaluation algorithm adapted from teh text summarization domain.
ERIC Educational Resources Information Center
Kamio, Yoko; Wolf, Julie; Fein, Deborah
2006-01-01
This study examined automatic processing of emotional faces in individuals with high-functioning Pervasive Developmental Disorders (HFPDD) using an affective priming paradigm. Sixteen participants (HFPDD and matched controls) were presented with happy faces, fearful faces or objects in both subliminal and supraliminal exposure conditions, followed…
An automatic lightning detection and photographic system
NASA Technical Reports Server (NTRS)
Wojtasinski, R. J.; Holley, L. D.; Gray, J. L.; Hoover, R. B.
1973-01-01
Conventional 35-mm camera is activated by an electronic signal every time lightning strikes in general vicinity. Electronic circuit detects lightning by means of antenna which picks up atmospheric radio disturbances. Camera is equipped with fish-eye lense, automatic shutter advance, and small 24-hour clock to indicate time when exposures are made.
An inexpensive compact automatic camera system for wildlife research
William R. Danielson; Richard M. DeGraaf; Todd K. Fuller
1996-01-01
This paper describes the design, conversion, and deployment of a reliable, compact, automatic multiple-exposure photographic system that was used to photograph nest predation events. This system may be the most versatile yet described in the literature because of its simplicity, portability, and dependability. The system was very reliable because it was designed around...
NASA Astrophysics Data System (ADS)
Dobra, R.; Pasculescu, D.; Risteiu, M.; Buica, G.; Jevremović, V.
2017-06-01
This paper describe some possibilities to minimize voltages switching-off risks from the mining power networks, in case of insulated resistance faults by using a predictive diagnose method. The cables from the neutral insulated power networks (underground mining) are designed to provide a flexible electrical connection between portable or mobile equipment and a point of supply, including main feeder cable for continuous miners, pump cable, and power supply cable. An electronic protection for insulated resistance of mining power cables can be made using this predictive strategy. The main role of electronic relays for insulation resistance degradation of the electrical power cables, from neutral insulated power networks, is to provide a permanent measurement of the insulated resistance between phases and ground, in order to switch-off voltage when the resistance value is below a standard value. The automat system of protection is able to signalize the failure and the human operator will be early informed about the switch-off power and will have time to take proper measures to fix the failure. This logic for fast and automat switch-off voltage without aprioristic announcement is suitable for the electrical installations, realizing so a protection against fires and explosion. It is presented an algorithm and an anticipative relay for insulated resistance control from three-phase low voltage installations with insulated neutral connection.
Off-Campus Study Centers for Federal Employees, Fiscal Year 1969.
ERIC Educational Resources Information Center
Civil Service Commission, Washington, DC. Bureau of Training.
One of three major training and educational resource publications from the Civil Service Commission, this directory provides information on individual off campus study centers for Federal Employees. Numbers of centers and participants are tabulated by agency and by state or other geographic location. Cooperating institutions, programs or course…
Off-Campus Centers for Federal Employees.
ERIC Educational Resources Information Center
Civil Service Commission, Washington, DC. Bureau of Training.
Designed to give information on off campus study centers for Federal employees, this directory tabulates the number of centers and participants by agency and by state or other geographic location, and indicates the cooperating institutions, programs or course offerings, eligibility for attendance, general items of interest, and sources of further…
Bailey, Norman G.; Aaron, John M.
1982-01-01
During June 1979, the U.S. Geological Survey (USGS) collected 4,032 km of single-channel seismic-reflection data from the Atlantic Continental Slope and Rise off New England. The work was conducted aboard R/V JAMES M. GILLISS (cruise GS-7903-3). The purpose of the cruise was to determine the characteristics of mass sediment movement on the Continental Slope, and to study and correlate the stratigraphy of the Jurassic and Cretaceous strata lying north and south of the New England seamount chain.Seismic instrumentation included 40-in3, 160-in3, and 500-in3 airguns; a Teledyne 800-joule minisparker system; a 3-5-kHz to 7-kHz, hull-mounted tunable transducer; and a 7-channel analog tape recorder.Navigation control during the cruise was provided by a Western Integrated Navigation System capable of integrating satellite, rho-rho Loran-C, hyperbolic Loran-C, gyro compass, and doppler speed-log position data. The prime navigation sensor was the rho-rho Loran-C automatically recorded at 20-second intervals and manually plotted every 15 minutes, backed up by hyperbolic Loran-C fixes automatically recorded every 5 minutes.Of the 4,032 km of data collected, 3,257 km of 3-5-kHz, minisparker and 40-in3 airgun were for the sediment-slump studand the other 775 km of 3-5-kHz, minis parker, 160-in3 air gun and 500-in3 airgun were for the deep stratigraphy study. Overall, the quality of the data is excellent with good resolution and penetration.The original data may be examined at the U.S. Geological Survey, Woods Hole, MA 02543. Copies of the data can be purchased only from the National Geophysical and Solar-Terrestrial Data Center, NOAA/EDIS/NGSDC, Code D621, 325 Broadway, Boulder, CO 80303 (303-497-6338).
Rapid Source Characterization of the 2011 Mw 9.0 off the Pacific coast of Tohoku Earthquake
Hayes, Gavin P.
2011-01-01
On March 11th, 2011, a moment magnitude 9.0 earthquake struck off the coast of northeast Honshu, Japan, generating what may well turn out to be the most costly natural disaster ever. In the hours following the event, the U.S. Geological Survey National Earthquake Information Center led a rapid response to characterize the earthquake in terms of its location, size, faulting source, shaking and slip distributions, and population exposure, in order to place the disaster in a framework necessary for timely humanitarian response. As part of this effort, fast finite-fault inversions using globally distributed body- and surface-wave data were used to estimate the slip distribution of the earthquake rupture. Models generated within 7 hours of the earthquake origin time indicated that the event ruptured a fault up to 300 km long, roughly centered on the earthquake hypocenter, and involved peak slips of 20 m or more. Updates since this preliminary solution improve the details of this inversion solution and thus our understanding of the rupture process. However, significant observations such as the up-dip nature of rupture propagation and the along-strike length of faulting did not significantly change, demonstrating the usefulness of rapid source characterization for understanding the first order characteristics of major earthquakes.
DOT National Transportation Integrated Search
1977-06-01
In 1975, to further the development and to refine and dmonstrate multiuser Automatic Vehicle Monitoring (AVM) application, the Urban Mass Transportation Administration and the Transportation Systems Center (TSC) initiated a two-phase program. Phase I...
Bio-inspired color image enhancement model
NASA Astrophysics Data System (ADS)
Zheng, Yufeng
2009-05-01
Human being can perceive natural scenes very well under various illumination conditions. Partial reasons are due to the contrast enhancement of center/surround networks and opponent analysis on the human retina. In this paper, we propose an image enhancement model to simulate the color processes in the human retina. Specifically, there are two center/surround layers, bipolar/horizontal and ganglion/amacrine; and four color opponents, red (R), green (G), blue (B), and yellow (Y). The central cell (bipolar or ganglion) takes the surrounding information from one or several horizontal or amacrine cells; and bipolar and ganglion both have ON and OFF sub-types. For example, a +R/-G bipolar (red-center- ON/green-surround-OFF) will be excited if only the center is illuminated, or inhibited if only the surroundings (bipolars) are illuminated, or stay neutral if both center and surroundings are illuminated. Likewise, other two color opponents with ON-center/OFF-surround, +G/-R and +B/-Y, follow the same rules. The yellow (Y) channel can be obtained by averaging red and green channels. On the other hand, OFF-center/ON-surround bipolars (i.e., -R/+G and -G/+R, but no - B/+Y) are inhibited when the center is illuminated. An ON-bipolar (or OFF-bipolar) only transfers signals to an ONganglion (or OFF-ganglion), where amacrines provide surrounding information. Ganglion cells have strong spatiotemporal responses to moving objects. In our proposed enhancement model, the surrounding information is obtained using weighted average of neighborhood; excited or inhibited can be implemented with pixel intensity increase or decrease according to a linear or nonlinear response; and center/surround excitations are decided by comparing their intensities. A difference of Gaussian (DOG) model is used to simulate the ganglion differential response. Experimental results using natural scenery pictures proved that, the proposed image enhancement model by simulating the two-layer center/surrounding retinal networks can effectively enhance color images in terms of color contrast and image details.
Remote Observations of the Lunar Sodium Exosphere
NASA Astrophysics Data System (ADS)
Morgan, T. H.; Killen, R. M.; Potter, A. E.
2015-12-01
We have designed, built and installed a small robotic coronagraph at the Winer Observatory in Sonoita, Arizona, in order to observe the sodium exosphere out to one-half degree around the Moon. We have observed every available clear night from our home base at Goddard Space Flight Center for several lunations in 2015, and thus have a long baseline of sodium exospheric calibrated images. We employ an Andover temperature-controlled 1.5 Å wide narrow-band filter centered on the sodium D2 line, and a similar 1.5 Å filter centered blueward of the D2 line by 5 Å. This filter would yield a sodium signal at least 24% of the scattered lunar light at first quarter. Exposures of 10 minutes are required to image the sodium corona at good signal to noise. Following each exposure pair, taking a 0.1 sec exposure with the open filter collects on- and off-band images of the lunar surface. An example of our resulting image of the sodium corona is shown in Figure 1, with the image of the moon's disk (taken subsequently to the occulted coronal image) superimposed on the occulting disk, thus showing the position and phase of the moon under the disk. We will compare our lunar model derived from these observations with the data from the UV spectrograph onboard the LADEE spacecraft. Figure 1. An image of the lunar sodium corona obtained on March 26, 2015 is shown with the lunar surface superimposed on the coronagraphic image. Using various sized occulting disks, depending on lunar phase, we observe the corona very close to the lunar surface with no scattered light.
Schlee, John Stevens
1978-01-01
Available are two multichannel profiles collected by Digicon Geophysical Corporation in 1975 using a 48-channel streamer (3600 m long). and a 27.9 cu. liter air gun array. They were processed in Denver on the Phoenix "I" by William C. Patterson. The processing included demultiplexing and resampling, geometry and common-depth-point definition, velocity analysis, noise muting, band-pass filtering, time-variant filtering, time-variant deconvolution, and automatic gain control (AGC) scaling, prior to the final profile playout.The release includes parts of two lines off the mid-atlantic continental margin (see map) over the Baltimore Canyon trough. These profiles were collected as part of a regional grid over the offshore Atlantic sedimentary basins, as a part of a continuing program to assess the resource potential using non-proprietary data Line 11 is a cross shelf profile (233 ken long) taken across the shelf, slope and upper rise off Virginia (southern Baltimore Canyon trough). Line 12 (shotpoint 1Ol- 6011, parts A, 8, C and D) is an along-the-shelf profiler and stretches from the Cape Hatteras IPOD line to line 2, at the northern part of the Baltimore Canyon trough), a distance of 591 km.These profiles may be viewed at the U.S. Geological Survey, Atlantic Gulf of Mexico, Office of Marine Geology, Quissett campus, Building B, Woods Hole, Massachusetts 02543, and at the U.S. Geological Survey, Branch of Oil and Gas Resources, Denver Federal Center, Building 25, Denver. Colorado 80225. Copies of the profiles can be purchased from the Nations Geophysical and Solar-Terrestrial Data Center, Environmental Data Service- NOAA, Code D621 Boulder, Colorado 80303.
Tozer, Sarah A; Kelly, Seamus; O'Mahony, Cian; Daly, E J; Nash, J F
2015-09-01
Realistic estimates of chemical aggregate exposure are needed to ensure consumer safety. As exposure estimates are a critical part of the equation used to calculate acceptable "safe levels" and conduct quantitative risk assessments, methods are needed to produce realistic exposure estimations. To this end, a probabilistic aggregate exposure model was developed to estimate consumer exposure from several rinse off personal cleansing products containing the anti-dandruff preservative zinc pyrithione. The model incorporates large habits and practices surveys, containing data on frequency of use, amount applied, co-use along with market share, and combines these data at the level of the individual based on subject demographics to better estimate exposure. The daily-applied exposure (i.e., amount applied to the skin) was 3.79 mg/kg/day for the 95th percentile consumer. The estimated internal dose for the 95th percentile exposure ranged from 0.01-1.29 μg/kg/day after accounting for retention following rinsing and dermal penetration of ZnPt. This probabilistic aggregate exposure model can be used in the human safety assessment of ingredients in multiple rinse-off technologies (e.g., shampoo, bar soap, body wash, and liquid hand soap). In addition, this model may be used in other situations where refined exposure assessment is required to support a chemical risk assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Energy Modeling Capabilities in ORD's Air, Climate and ...
Presentation to ACE Centers Kick-Off Meeting highlighting energy modeling work, capabilities and tools that are under development in ORD/NRMRL under the ACE Program. Presentation to ACE Centers Kick-Off Meeting
Lin, Zhicheng; He, Sheng
2012-10-25
Object identities ("what") and their spatial locations ("where") are processed in distinct pathways in the visual system, raising the question of how the what and where information is integrated. Because of object motions and eye movements, the retina-based representations are unstable, necessitating nonretinotopic representation and integration. A potential mechanism is to code and update objects according to their reference frames (i.e., frame-centered representation and integration). To isolate frame-centered processes, in a frame-to-frame apparent motion configuration, we (a) presented two preceding or trailing objects on the same frame, equidistant from the target on the other frame, to control for object-based (frame-based) effect and space-based effect, and (b) manipulated the target's relative location within its frame to probe frame-centered effect. We show that iconic memory, visual priming, and backward masking depend on objects' relative frame locations, orthogonal of the retinotopic coordinate. These findings not only reveal that iconic memory, visual priming, and backward masking can be nonretinotopic but also demonstrate that these processes are automatically constrained by contextual frames through a frame-centered mechanism. Thus, object representation is robustly and automatically coupled to its reference frame and continuously being updated through a frame-centered, location-specific mechanism. These findings lead to an object cabinet framework, in which objects ("files") within the reference frame ("cabinet") are orderly coded relative to the frame.
The charging security study of electric vehicle charging spot based on automatic testing platform
NASA Astrophysics Data System (ADS)
Li, Yulan; Yang, Zhangli; Zhu, Bin; Ran, Shengyi
2018-03-01
With the increasing of charging spots, the testing of charging security and interoperability becomes more and more urgent and important. In this paper, an interface simulator for ac charging test is designed, the automatic testing platform for electric vehicle charging spots is set up and used to test and analyze the abnormal state during the charging process. On the platform, the charging security and interoperability of ac charging spots and IC-CPD can be checked efficiently, the test report can be generated automatically with No artificial reading error. From the test results, the main reason why the charging spot is not qualified is that the power supply cannot be cut off in the prescribed time when the charging anomaly occurs.
NASA Astrophysics Data System (ADS)
Chawla, Viveak Kumar; Chanda, Arindam Kumar; Angra, Surjit
2018-03-01
The flexible manufacturing system (FMS) constitute of several programmable production work centers, material handling systems (MHSs), assembly stations and automatic storage and retrieval systems. In FMS, the automatic guided vehicles (AGVs) play a vital role in material handling operations and enhance the performance of the FMS in its overall operations. To achieve low makespan and high throughput yield in the FMS operations, it is highly imperative to integrate the production work centers schedules with the AGVs schedules. The Production schedule for work centers is generated by application of the Giffler and Thompson algorithm under four kind of priority hybrid dispatching rules. Then the clonal selection algorithm (CSA) is applied for the simultaneous scheduling to reduce backtracking as well as distance travel of AGVs within the FMS facility. The proposed procedure is computationally tested on the benchmark FMS configuration from the literature and findings from the investigations clearly indicates that the CSA yields best results in comparison of other applied methods from the literature.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-19
..., 2011. In addition to the anti-entrapment devices or systems, each public pool and spa in the United... release system; suction-limiting vent system; gravity drainage system; automatic pump shut-off system or...
1983-05-20
features of off-load and on-load release gears. Model tests in a wave tank have shown this system to reliably provide automatic release of the boat. It...similar to the lifeboats. The approved release hook system automatically releases the raft when the hook is aet during lowering and the raft becomes...the severe storm; the lack of written casualty control procedures; the inadequate ballast system pump and piping design and arrangement for dewatering
Pulsed-Plasma Disinfection of Water Containing Escherichia coli
NASA Astrophysics Data System (ADS)
Satoh, Kohki; MacGregor, Scott J.; Anderson, John G.; Woolsey, Gerry A.; Fouracre, R. Anthony
2007-03-01
The disinfection of water containing the microorganism, Escherichia coli (E. coli) by exposure to a pulsed-discharge plasma generated above the water using a multineedle electrode (plasma-exposure treatment), and by sparging the off-gas of the pulsed plasma into the water (off-gas-sparging treatment), is performed in the ambient gases of air, oxygen, and nitrogen. For the off-gas-sparging treatment, bactericidal action is observed only when oxygen is used as the ambient gas, and ozone is found to generate the bactericidal action. For the plasma-exposure treatment, the density of E. coli bacteria decreases exponentially with plasma-exposure time for all the ambient gases. It may be concluded that the main contributors to E. coli inactivation are particle species produced by the pulsed plasma. For the ambient gases of air and nitrogen, the influence of acidification of the water in the system, as a result of pulsed-plasma exposure, may also contribute to the decay of E. coli density.
Hankey, Steve; Lindsey, Greg; Marshall, Julian D.
2016-01-01
Background: Providing infrastructure and land uses to encourage active travel (i.e., bicycling and walking) are promising strategies for designing health-promoting cities. Population-level exposure to air pollution during active travel is understudied. Objectives: Our goals were a) to investigate population-level patterns in exposure during active travel, based on spatial estimates of bicycle traffic, pedestrian traffic, and particulate concentrations; and b) to assess how those exposure patterns are associated with the built environment. Methods: We employed facility–demand models (active travel) and land use regression models (particulate concentrations) to estimate block-level (n = 13,604) exposure during rush-hour (1600–1800 hours) in Minneapolis, Minnesota. We used the model-derived estimates to identify land use patterns and characteristics of the street network that are health promoting. We also assessed how exposure is correlated with indicators of health disparities (e.g., household income, proportion of nonwhite residents). Our work uses population-level rates of active travel (i.e., traffic flows) rather than the probability of walking or biking (i.e., “walkability” or “bikeability”) to assess exposure. Results: Active travel often occurs on high-traffic streets or near activity centers where particulate concentrations are highest (i.e., 20–42% of active travel occurs on blocks with high population-level exposure). Only 2–3% of blocks (3–8% of total active travel) are “sweet spots” (i.e., high active travel, low particulate concentrations); sweet spots are located a) near but slightly removed from the city-center or b) on off-street trails. We identified 1,721 blocks (~ 20% of local roads) where shifting active travel from high-traffic roads to adjacent low-traffic roads would reduce exposure by ~ 15%. Active travel is correlated with population density, land use mix, open space, and retail area; particulate concentrations were mostly unchanged with land use. Conclusions: Public health officials and urban planners may use our findings to promote healthy transportation choices. When designing health-promoting cities, benefits (physical activity) as well as hazards (air pollution) should be evaluated. Citation: Hankey S, Lindsey G, Marshall JD. 2017. Population-level exposure to particulate air pollution during active travel: planning for low-exposure, health-promoting cities. Environ Health Perspect 125:–534; http://dx.doi.org/10.1289/EHP442 PMID:27713109
Pelissier, Fanny; de Haro, Luc; Cardona, Florence; Picot, Cyndie; Puskarczyk, Emmanuel; Sapori, Jean-Marc; Tournoud, Christine; Franchitto, Nicolas
2017-04-01
Alcohol use disorders are frequently associated with self-intoxication in attempted suicide. In France since 2008, the off-label use of baclofen for treatment of alcohol dependence has greatly increased, leading to temporary regulation of use of the drug. At the request of the national authorities, the French Poison Control Centers carried out a retrospective survey to give an overview of baclofen exposure in this population. A retrospective study was carried out from January 2008 to December 2013, focusing on baclofen exposures in alcohol-dependent patients managed by the nine national French Poison Control Centers. 294 observations of baclofen exposures in alcohol-dependent patients were identified in our database. Of these, 220 were suicide attempts by self-poisoning and 74 were unintentional. The mean age of patients was 41.7 years, with a sex-ratio of 1.6. Patients attempting suicide with baclofen were younger than those with unintentional exposures, and 43.6% of them were women (vs 22.9%, p < 0.01). The mean supposed ingested dose was higher (480.7 mg) in patients who attempted suicide (vs 192.5 mg, p < 0.0001). 21.8% of intentional exposures involved baclofen alone. Psychiatric comorbidity (50.4%) was more frequent in the group of self-poisoning (p < 0.001). 132 patients were coded as severely exposed (60.0%). Nine victims died, but the causal link between self-poisoning with baclofen and fatal outcome should be interpreted with particular caution. Baclofen self-poisoning by alcohol-dependent patients is a serious concern for the French health authorities. Our results are similar to those previously published, suggesting that most patients with baclofen overdose should be admitted to an intermediate or intensive care unit as the clinical course requires close monitoring. Because suicidal ideation and suicide attempts are more prevalent in people with substance use disorders than in the general population, and because of the lack of recommendations governing baclofen prescription in such a situation, its use needs to be better controlled.
A strategy planner for NASA robotics applications
NASA Technical Reports Server (NTRS)
Brodd, S. S.
1985-01-01
Automatic strategy or task planning is an important element of robotics systems. A strategy planner under development at Goddard Space Flight Center automatically produces robot plans for assembly, disassembly, or repair of NASA spacecraft from computer aided design descriptions of the individual parts of the spacecraft.
Johanson, Gunnar
2017-01-01
Abstract Containerized cargo shipment makes up the backbone of international trade. The principal aim of this cross-sectional study was to establish a qualitative and quantitative description of gaseous fumigants and volatile off-gassing substances facing workers tasked with entering shipping containers. A total of 372 packed and 119 empty shipping containers were sampled in six ports and two distribution centers in Sweden. Fourier-transform infrared spectrometry (FTIR) and photoionization detection (PID) were the analytical methods applied to the bulk of samples. A small number of adsorbent samples were analyzed using gas chromatography–mass spectrometry (GC–MS). The results were compared to Swedish occupational exposure limits (OELs), the closest parallel to relevant work situations. Based on the FTIR analyses, 30 of 249 (12%) containers arrived with concentrations of fumigants and off-gassing substances above the 8-h OELs and close to 7% were above the short-term exposure limits. Eight detected chemicals were classified as carcinogens and 4% of the containers arrived with levels of carcinogens above the OELs, at a maximum 30 times the 8-h OEL. Considerable differences were observed between ports, ranging from 0 to 33% of containers arriving with concentrations above the OELs. It is believed that all observation results, apart from a single instance of a confirmed fumigant, phosphine, at 3 p.p.m., and possibly three instances of carbon dioxide, can be attributed to off-gassing substances. The FTIR methodology proved useful for quick preliminary checks and in-depth screening and identification. The PID method produced both false-negative and false-positive results where only 48% matched the FTIR observations. Adsorbent sampling with GC–MS analysis was useful for confirming volatile organic compounds but was deemed too slow for day-to-day screening. The high frequency of contaminated containers, the detection of several carcinogens, and the sporadic occurrences of high levels of fumigants are serious concerns that need to be properly recognized in order to protect the workers at risk. PMID:28395344
Averaging scheme for atomic resolution off-axis electron holograms.
Niermann, T; Lehmann, M
2014-08-01
All micrographs are limited by shot-noise, which is intrinsic to the detection process of electrons. For beam insensitive specimen this limitation can in principle easily be circumvented by prolonged exposure times. However, in the high-resolution regime several instrumental instabilities limit the applicable exposure time. Particularly in the case of off-axis holography the holograms are highly sensitive to the position and voltage of the electron-optical biprism. We present a novel reconstruction algorithm to average series of off-axis holograms while compensating for specimen drift, biprism drift, drift of biprism voltage, and drift of defocus, which all might cause problematic changes from exposure to exposure. We show an application of the algorithm utilizing also the possibilities of double biprism holography, which results in a high quality exit-wave reconstruction with 75 pm resolution at a very high signal-to-noise ratio. Copyright © 2014 Elsevier Ltd. All rights reserved.
Restrepo, John F; Garcia-Sucerquia, Jorge
2012-02-15
We present an automatic procedure for 3D tracking of micrometer-sized particles with high-NA digital lensless holographic microscopy. The method uses a two-feature approach to search for the best focal planes and to distinguish particles from artifacts or other elements on the reconstructed stream of the holograms. A set of reconstructed images is axially projected onto a single image. From the projected image, the centers of mass of all the reconstructed elements are identified. Starting from the centers of mass, the morphology of the profile of the maximum intensity along the reconstruction direction allows for the distinguishing of particles from others elements. The method is tested with modeled holograms and applied to automatically track micrometer-sized bubbles in a sample of 4 mm3 of soda.
Goodall, Catherine E.; Slater, Michael D.
2010-01-01
Alcohol advertisements may influence impulsive, risky behaviors indirectly, via automatically-activated attitudes toward alcohol. Results from an experiment in which participants were exposed to either four alcohol advertisements, four control advertisements, or four drunk driving public service advertisements, suggested that alcohol advertisements had more measurable effects on implicit, than on explicit attitude measures. Moreover, there were significant indirect paths from alcohol advertisement exposure through automatically-activated alcohol attitudes on willingness to engage in risky alcohol-related behaviors, notably drinking and driving. A mechanism that may explain how these advertisements activate automatic, non-deliberative alcohol attitudes was investigated. Associative evidence was found supportive of an evaluative conditioning mechanism, in which positive responses to an alcohol advertisement may lead to more positive automatically-activated attitudes toward alcohol itself. PMID:21258609
Goodall, Catherine E; Slater, Michael D
2010-10-01
Alcohol advertisements may influence impulsive, risky behaviors indirectly, via automatically-activated attitudes toward alcohol. Results from an experiment in which participants were exposed to either four alcohol advertisements, four control advertisements, or four drunk driving public service advertisements, suggested that alcohol advertisements had more measurable effects on implicit, than on explicit attitude measures. Moreover, there were significant indirect paths from alcohol advertisement exposure through automatically-activated alcohol attitudes on willingness to engage in risky alcohol-related behaviors, notably drinking and driving. A mechanism that may explain how these advertisements activate automatic, non-deliberative alcohol attitudes was investigated. Associative evidence was found supportive of an evaluative conditioning mechanism, in which positive responses to an alcohol advertisement may lead to more positive automatically-activated attitudes toward alcohol itself.
Handbook. Midwest Center for Off-Campus Studies.
ERIC Educational Resources Information Center
Midwest Center for Off-Campus Studies, Lincoln, IL.
The Midwest Center for Off-Campus Studies offers students the opportunity to learn in a holistic manner by inserting them into a new community, either domestic or foreign, so that they can not only see the physical characteristics of the site, but can experience learning. Although the Center is at present an association of five Illinois two-year…
Bullet-Block Science Video Puzzle
ERIC Educational Resources Information Center
Shakur, Asif
2015-01-01
A science video blog, which has gone viral, shows a wooden block shot by a vertically aimed rifle. The video shows that the block hit dead center goes exactly as high as the one shot off-center. (Fig. 1). The puzzle is that the block shot off-center carries rotational kinetic energy in addition to the gravitational potential energy. This leads a…
Vanaelst, Jolien; Spruyt, Adriaan; De Houwer, Jan
2016-01-01
We demonstrate that feature-specific attention allocation influences the way in which repeated exposure modulates implicit and explicit evaluations toward fear-related stimuli. During an exposure procedure, participants were encouraged to assign selective attention either to the evaluative meaning (i.e., Evaluative Condition) or a non-evaluative, semantic feature (i.e., Semantic Condition) of fear-related stimuli. The influence of the exposure procedure was captured by means of a measure of implicit evaluation, explicit evaluative ratings, and a measure of automatic approach/avoidance tendencies. As predicted, the implicit measure of evaluation revealed a reduced expression of evaluations in the Semantic Condition as compared to the Evaluative Condition. Moreover, this effect generalized toward novel objects that were never presented during the exposure procedure. The explicit measure of evaluation mimicked this effect, although it failed to reach conventional levels of statistical significance. No effects were found in terms of automatic approach/avoidance tendencies. Potential implications for the treatment of anxiety disorders are discussed. PMID:27242626
Vanaelst, Jolien; Spruyt, Adriaan; De Houwer, Jan
2016-01-01
We demonstrate that feature-specific attention allocation influences the way in which repeated exposure modulates implicit and explicit evaluations toward fear-related stimuli. During an exposure procedure, participants were encouraged to assign selective attention either to the evaluative meaning (i.e., Evaluative Condition) or a non-evaluative, semantic feature (i.e., Semantic Condition) of fear-related stimuli. The influence of the exposure procedure was captured by means of a measure of implicit evaluation, explicit evaluative ratings, and a measure of automatic approach/avoidance tendencies. As predicted, the implicit measure of evaluation revealed a reduced expression of evaluations in the Semantic Condition as compared to the Evaluative Condition. Moreover, this effect generalized toward novel objects that were never presented during the exposure procedure. The explicit measure of evaluation mimicked this effect, although it failed to reach conventional levels of statistical significance. No effects were found in terms of automatic approach/avoidance tendencies. Potential implications for the treatment of anxiety disorders are discussed.
Wireless sensor network effectively controls center pivot irrigation of sorghum
USDA-ARS?s Scientific Manuscript database
Robust automatic irrigation scheduling has been demonstrated using wired sensors and sensor network systems with subsurface drip and moving irrigation systems. However, there are limited studies that report on crop yield and water use efficiency resulting from the use of wireless networks to automat...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Z; Vijayan, S; Oines, A
Purpose: To compare PCXMC and EGSnrc calculated organ and effective radiation doses from cone-beam computed tomography (CBCT) and interventional fluoroscopically-guided procedures using automatic exposure-event grouping. Methods: For CBCT, we used PCXMC20Rotation.exe to automatically calculate the doses and compared the results to those calculated using EGSnrc with the Zubal patient phantom. For interventional procedures, we use the dose tracking system (DTS) which we previously developed to produce a log file of all geometry and exposure parameters for every x-ray pulse during a procedure, and the data in the log file is input into PCXMC and EGSnrc for dose calculation. A MATLABmore » program reads data from the log files and groups similar exposures to reduce calculation time. The definition files are then automatically generated in the format used by PCXMC and EGSnrc. Processing is done at the end of the procedure after all exposures are completed. Results: For the Toshiba Infinix CBCT LCI-Middle-Abdominal protocol, most organ doses calculated with PCXMC20Rotation closely matched those calculated with EGSnrc. The effective doses were 33.77 mSv with PCXMC20Rotation and 32.46 mSv with EGSnrc. For a simulated interventional cardiac procedure, similar close agreement in organ dose was obtained between the two codes; the effective doses were 12.02 mSv with PCXMC and 11.35 mSv with EGSnrc. The calculations can be completed on a PC without manual intervention in less than 15 minutes with PCXMC and in about 10 hours with EGSnrc, depending on the level of data grouping and accuracy desired. Conclusion: Effective dose and most organ doses in CBCT and interventional radiology calculated by PCXMC closely match those calculated by EGSnrc. Data grouping, which can be done automatically, makes the calculation time with PCXMC on a standard PC acceptable. This capability expands the dose information that can be provided by the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less
Software for Planning Scientific Activities on Mars
NASA Technical Reports Server (NTRS)
Ai-Chang, Mitchell; Bresina, John; Jonsson, Ari; Hsu, Jennifer; Kanefsky, Bob; Morris, Paul; Rajan, Kanna; Yglesias, Jeffrey; Charest, Len; Maldague, Pierre
2003-01-01
Mixed-Initiative Activity Plan Generator (MAPGEN) is a ground-based computer program for planning and scheduling the scientific activities of instrumented exploratory robotic vehicles, within the limitations of available resources onboard the vehicle. MAPGEN is a combination of two prior software systems: (1) an activity-planning program, APGEN, developed at NASA s Jet Propulsion Laboratory and (2) the Europa planner/scheduler from NASA Ames Research Center. MAPGEN performs all of the following functions: Automatic generation of plans and schedules for scientific and engineering activities; Testing of hypotheses (or what-if analyses of various scenarios); Editing of plans; Computation and analysis of resources; and Enforcement and maintenance of constraints, including resolution of temporal and resource conflicts among planned activities. MAPGEN can be used in either of two modes: one in which the planner/scheduler is turned off and only the basic APGEN functionality is utilized, or one in which both component programs are used to obtain the full planning, scheduling, and constraint-maintenance functionality.
Automated Spatiotemporal Analysis of Fibrils and Coronal Rain Using the Rolling Hough Transform
NASA Astrophysics Data System (ADS)
Schad, Thomas
2017-09-01
A technique is presented that automates the direction characterization of curvilinear features in multidimensional solar imaging datasets. It is an extension of the Rolling Hough Transform (RHT) technique presented by Clark, Peek, and Putman ( Astrophys. J. 789, 82, 2014), and it excels at rapid quantification of spatial and spatiotemporal feature orientation even for applications with a low signal-to-noise ratio. It operates on a pixel-by-pixel basis within a dataset and reliably quantifies orientation even for locations not centered on a feature ridge, which is used here to derive a quasi-continuous map of the chromospheric fine-structure projection angle. For time-series analysis, a procedure is developed that uses a hierarchical application of the RHT to automatically derive the apparent motion of coronal rain observed off-limb. Essential to the success of this technique is the formulation presented in this article for the RHT error analysis as it provides a means to properly filter results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alfred, J.W.; Shinn, J.M. Jr; Kirby, C.E.
1976-07-01
This report describes a low-cost solar home heating system to supplement the home-owner's present warm-air heating system. It has three parts: (1) A brief background on solar heating, (2) Langley's experience with a demonstration system, and (3) information for the home-owner who wishes to construct such a system. Instructions are given for a solar heating installation in which he supplies all labor needed to install off-the-shelf components estimated to cost $2000. These components, which include solar collector, heat exchanger, water pump, storage tank, piping, and controls to make the system completely automatic, are readily available at local lumber yards, hardwaremore » stores, and plumbing supply stores, and they are relatively simple to install. Manufacturers and prices of each component used and a rough cost analysis based on these prices are given for the owner's convenience. This report also gives performance data obtained from a demonstration system which has been built and tested at the Langley Research Center.« less
The Associate Principal Astronomer for AI Management of Automatic Telescopes
NASA Technical Reports Server (NTRS)
Henry, Gregory W.
1998-01-01
This research program in scheduling and management of automatic telescopes had the following objectives: 1. To field test the 1993 Automatic Telescope Instruction Set (ATIS93) programming language, which was specifically developed to allow real-time control of an automatic telescope via an artificial intelligence scheduler running on a remote computer. 2. To develop and test the procedures for two-way communication between a telescope controller and remote scheduler via the Internet. 3. To test various concepts in Al scheduling being developed at NASA Ames Research Center on an automatic telescope operated by Tennessee State University at the Fairborn Observatory site in southern Arizona. and 4. To develop a prototype software package, dubbed the Associate Principal Astronomer, for the efficient scheduling and management of automatic telescopes.
A two-phase model of resource allocation in visual working memory.
Ye, Chaoxiong; Hu, Zhonghua; Li, Hong; Ristaniemi, Tapani; Liu, Qiang; Liu, Taosheng
2017-10-01
Two broad theories of visual working memory (VWM) storage have emerged from current research, a discrete slot-based theory and a continuous resource theory. However, neither the discrete slot-based theory or continuous resource theory clearly stipulates how the mental commodity for VWM (discrete slot or continuous resource) is allocated. Allocation may be based on the number of items via stimulus-driven factors, or it may be based on task demands via voluntary control. Previous studies have obtained conflicting results regarding the automaticity versus controllability of such allocation. In the current study, we propose a two-phase allocation model, in which the mental commodity could be allocated only by stimulus-driven factors in the early consolidation phase. However, when there is sufficient time to complete the early phase, allocation can enter the late consolidation phase, where it can be flexibly and voluntarily controlled according to task demands. In an orientation recall task, we instructed participants to store either fewer items at high-precision or more items at low-precision. In 3 experiments, we systematically manipulated memory set size and exposure duration. We did not find an effect of task demands when the set size was high and exposure duration was short. However, when we either decreased the set size or increased the exposure duration, we found a trade-off between the number and precision of VWM representations. These results can be explained by a two-phase model, which can also account for previous conflicting findings in the literature. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Automatic-Control System for Safer Brazing
NASA Technical Reports Server (NTRS)
Stein, J. A.; Vanasse, M. A.
1986-01-01
Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.
Aurrekoetxea, Juan J; Murcia, Mario; Rebagliato, Marisa; López, María José; Castilla, Ane Miren; Santa-Marina, Loreto; Guxens, Mónica; Fernández-Somoano, Ana; Espada, Mercedes; Lertxundi, Aitana; Tardón, Adonina; Ballester, Ferran
2013-01-01
Objectives To estimate the prevalence and factors associated with smoking and misclassification in pregnant women from INMA (INfancia y Medio Ambiente, Environment and Childhood) project, Spain, and to assess the optimal cut-offs for urinary cotinine (UC) that best distinguish daily and occasional smokers with varying levels of second-hand smoke (SHS) exposure. Design We used logistic regression models to study the relationship between sociodemographic variables and self-reported smoking and misclassification (self-reported non-smokers with UC >50 ng/ml). Receiver operating characteristic (ROC) curves were used to calculate the optimal cut-off point for discriminating smokers. The cut-offs were also calculated after stratification among non-smokers by the number of sources of SHS exposure. The cut-off points used to discriminate smoking status were the level of UC given by Youden's index and for 50 and 100 ng/ml for daily smokers, or 25 and 50 ng/ml for occasional smokers. Participants At the third trimester of pregnancy, 2263 pregnant women of the INMA Project were interviewed between 2004 and 2008 and a urine sample was collected. Results Prevalence of self-reported smokers at the third trimester of pregnancy was 18.5%, and another 3.9% misreported their smoking status. Variables associated with self-reported smoking and misreporting were similar, including born in Europe, educational level and exposure to SHS. The optimal cut-off was 82 ng/ml (95% CI 42 to 133), sensitivity 95.2% and specificity 96.6%. The area under the ROC curve was 0.986 (95% CI 0.982 to 0.990). The cut-offs varied according to the SHS exposure level being 42 (95% CI 27 to 57), 82 (95% CI 46 to 136) and 106 ng/ml (95% CI 58 to 227) for not being SHS exposed, exposed to one, and to two or more sources of SHS, respectively. The optimal cut-off for discriminating occasional smokers from non-smokers was 27 ng/ml (95% CI 11 to 43). Conclusions Prevalence of smoking during pregnancy in Spain remains high. UC is a reliable biomarker for classifying pregnant women according to their smoking status. However, cut-offs would differ based on baseline exposure to SHS. PMID:23355667
Aurrekoetxea, Juan J; Murcia, Mario; Rebagliato, Marisa; López, María José; Castilla, Ane Miren; Santa-Marina, Loreto; Guxens, Mónica; Fernández-Somoano, Ana; Espada, Mercedes; Lertxundi, Aitana; Tardón, Adonina; Ballester, Ferran
2013-01-24
To estimate the prevalence and factors associated with smoking and misclassification in pregnant women from INMA (INfancia y Medio Ambiente, Environment and Childhood) project, Spain, and to assess the optimal cut-offs for urinary cotinine (UC) that best distinguish daily and occasional smokers with varying levels of second-hand smoke (SHS) exposure. We used logistic regression models to study the relationship between sociodemographic variables and self-reported smoking and misclassification (self-reported non-smokers with UC >50 ng/ml). Receiver operating characteristic (ROC) curves were used to calculate the optimal cut-off point for discriminating smokers. The cut-offs were also calculated after stratification among non-smokers by the number of sources of SHS exposure. The cut-off points used to discriminate smoking status were the level of UC given by Youden's index and for 50 and 100 ng/ml for daily smokers, or 25 and 50 ng/ml for occasional smokers. At the third trimester of pregnancy, 2263 pregnant women of the INMA Project were interviewed between 2004 and 2008 and a urine sample was collected. Prevalence of self-reported smokers at the third trimester of pregnancy was 18.5%, and another 3.9% misreported their smoking status. Variables associated with self-reported smoking and misreporting were similar, including born in Europe, educational level and exposure to SHS. The optimal cut-off was 82 ng/ml (95% CI 42 to 133), sensitivity 95.2% and specificity 96.6%. The area under the ROC curve was 0.986 (95% CI 0.982 to 0.990). The cut-offs varied according to the SHS exposure level being 42 (95% CI 27 to 57), 82 (95% CI 46 to 136) and 106 ng/ml (95% CI 58 to 227) for not being SHS exposed, exposed to one, and to two or more sources of SHS, respectively. The optimal cut-off for discriminating occasional smokers from non-smokers was 27 ng/ml (95% CI 11 to 43). Prevalence of smoking during pregnancy in Spain remains high. UC is a reliable biomarker for classifying pregnant women according to their smoking status. However, cut-offs would differ based on baseline exposure to SHS.
Lin, Zhicheng; He, Sheng
2012-01-01
Object identities (“what”) and their spatial locations (“where”) are processed in distinct pathways in the visual system, raising the question of how the what and where information is integrated. Because of object motions and eye movements, the retina-based representations are unstable, necessitating nonretinotopic representation and integration. A potential mechanism is to code and update objects according to their reference frames (i.e., frame-centered representation and integration). To isolate frame-centered processes, in a frame-to-frame apparent motion configuration, we (a) presented two preceding or trailing objects on the same frame, equidistant from the target on the other frame, to control for object-based (frame-based) effect and space-based effect, and (b) manipulated the target's relative location within its frame to probe frame-centered effect. We show that iconic memory, visual priming, and backward masking depend on objects' relative frame locations, orthogonal of the retinotopic coordinate. These findings not only reveal that iconic memory, visual priming, and backward masking can be nonretinotopic but also demonstrate that these processes are automatically constrained by contextual frames through a frame-centered mechanism. Thus, object representation is robustly and automatically coupled to its reference frame and continuously being updated through a frame-centered, location-specific mechanism. These findings lead to an object cabinet framework, in which objects (“files”) within the reference frame (“cabinet”) are orderly coded relative to the frame. PMID:23104817
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-31
... remove the automatic exemption from the nonmember deposits limit that had been granted to RegFlex FCUs... created a ``well capitalized standard'' based on the automatic designation criteria used in RegFlex. An... premises. ``Premises'' means any office, branch office, suboffice, service center, parking lot, facility...
NASA Astrophysics Data System (ADS)
Zhang, Shaojun; Xu, Xiping
2015-10-01
The 360-degree and all round looking camera, as its characteristics of suitable for automatic analysis and judgment on the ambient environment of the carrier by image recognition algorithm, is usually applied to opto-electronic radar of robots and smart cars. In order to ensure the stability and consistency of image processing results of mass production, it is necessary to make sure the centers of image planes of different cameras are coincident, which requires to calibrate the position of the image plane's center. The traditional mechanical calibration method and electronic adjusting mode of inputting the offsets manually, both exist the problem of relying on human eyes, inefficiency and large range of error distribution. In this paper, an approach of auto- calibration of the image plane of this camera is presented. The imaging of the 360-degree and all round looking camera is a ring-shaped image consisting of two concentric circles, the center of the image is a smaller circle and the outside is a bigger circle. The realization of the technology is just to exploit the above characteristics. Recognizing the two circles through HOUGH TRANSFORM algorithm and calculating the center position, we can get the accurate center of image, that the deviation of the central location of the optic axis and image sensor. The program will set up the image sensor chip through I2C bus automatically, we can adjusting the center of the image plane automatically and accurately. The technique has been applied to practice, promotes productivity and guarantees the consistent quality of products.
Phytotoxicity of citrus and subtropical fruits to acetaldehyde vapor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prasad, K.
1975-01-01
Several citrus and subtropical fruits (oranges, limes, lemons, mangos and papayas) were evaluated for phytotoxicity to acetaldehyde vapor. Exposure of fruits to 0.5 or 1% acetaldehyde vapor for 24 hr (low concentration-long exposure) did not produce skin injury or off-flavor in comparison with non-exposed fruits. This non-phytotoxic effect was also obtained at 5 to 20% acetaldehyde vapor for 10 to 15 min (high concentration-short exposure). However, acetaldehyde vapor concentration of 4% for 1 hr or 5% for 30 min (high concentration-long exposure) produced severe lenticel and skin injuries to the fruits. Exposure of fruits at these concentration also produced lackmore » of or off-flavor. Phytotoxicity of fruits to acetaldhyde vapor was a function of concentration and exposure.« less
NASA Astrophysics Data System (ADS)
Figuera Jaimes, R.; Bramich, D. M.; Skottfelt, J.; Kains, N.; Jørgensen, U. G.; Horne, K.; Dominik, M.; Alsubai, K. A.; Bozza, V.; Calchi Novati, S.; Ciceri, S.; D'Ago, G.; Galianni, P.; Gu, S.-H.; Harpsøe, K. B. W.; Haugbølle, T.; Hinse, T. C.; Hundertmark, M.; Juncher, D.; Korhonen, H.; Mancini, L.; Popovas, A.; Rabus, M.; Rahvar, S.; Scarpetta, G.; Schmidt, R. W.; Snodgrass, C.; Southworth, J.; Starkey, D.; Street, R. A.; Surdej, J.; Wang, X.-B.; Wertz, O.
2016-04-01
Aims: We aim to obtain time-series photometry of the very crowded central regions of Galactic globular clusters; to obtain better angular resolution thanhas been previously achieved with conventional CCDs on ground-based telescopes; and to complete, or improve, the census of the variable star population in those stellar systems. Methods: Images were taken using the Danish 1.54-m Telescope at the ESO observatory at La Silla in Chile. The telescope was equipped with an electron-multiplying CCD, and the short-exposure-time images obtained (ten images per second) were stacked using the shift-and-add technique to produce the normal-exposure-time images (minutes). Photometry was performed via difference image analysis. Automatic detection of variable stars in the field was attempted. Results: The light curves of 12 541 stars in the cores of ten globular clusters were statistically analysed to automatically extract the variable stars. We obtained light curves for 31 previously known variable stars (3 long-period irregular, 2 semi-regular, 20 RR Lyrae, 1 SX Phoenicis, 3 cataclysmic variables, 1 W Ursae Majoris-type and 1 unclassified) and we discovered 30 new variables (16 long-period irregular, 7 semi-regular, 4 RR Lyrae, 1 SX Phoenicis and 2 unclassified). Fluxes and photometric measurements for these stars are available in electronic form through the Strasbourg astronomical Data Center. Based on data collected by the MiNDSTEp team with the Danish 1.54m telescope at ESO's La Silla observatory in Chile.Full Table 1 is only available at CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/588/A128
Operating characteristics of tube-current-modulation techniques when scanning simple-shaped phantoms
NASA Astrophysics Data System (ADS)
Matsubara, Kosuke; Koshida, Kichiro; Lin, Pei-Jan Paul; Fukuda, Atsushi
2015-07-01
Our objective was to investigate the operating characteristics of tube current modulation (TCM) in computed tomography (CT) when scanning two types of simple-shaped phantoms. A tissueequivalent elliptical phantom and a homogeneous cylindrical step phantom comprising 16-, 24-, and 32-cm-diameter polymethyl methacrylate (PMMA) phantoms were scanned by using an automatic exposure control system with longitudinal (z-) and angular-longitudinal (xyz-) TCM and with a fixed tube current. The axial dose distribution throughout the elliptical phantom and the longitudinal dose distribution at the center of the cylindrical step phantom were measured by using a solid-state detector. Image noise was quantitatively measured at eight regions in the elliptical phantom and at 90 central regions in contiguous images over the full z extent of the cylindrical step phantom. The mean absorbed doses and the standard deviations in the elliptical phantom with z- and xyz-TCM were 12.3' 3.7 and 11.3' 3.5 mGy, respectively. When TCM was activated, some differences were observed in the absorbed doses of the left and the right measurement points. The average image noises in Hounsfield units (HU) and the standard deviations were 15.2' 2.4 and 15.9' 2.4 HU when using z- and xyz-TCM, respectively. With respect to the cylindrical step phantom under z-TCM, there were sudden decreases followed by increases in image noise at the interfaces with the 24- and 16-cm-diameter phantoms. The image noise of the 24-cm-diameter phantom was, relatively speaking, higher than those of the 16- and 32-cm-diameter phantoms. The simple-shaped phantoms used in this study can be employed to investigate the operating characteristics of automatic exposure control systems when specialized phantoms designed for that purpose are not available.
NASA Technical Reports Server (NTRS)
St. John, Clinton W.; Frederick, Michael Alan
2013-01-01
Flight-testing of a channeled center-body axisymmetric supersonic inlet design concept was conducted at the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center in collaboration with the NASA Glenn Research Center (Cleveland, Ohio) and TechLand Research, Inc. (North Olmsted, Ohio). This testing utilized the Propulsion Flight Test Fixture, flown on the NASA F-15B research test bed airplane (NASA tail number 836) at local experiment Mach numbers up to 1.50. The translating channeled center-body inlet was designed by TechLand Research, Inc. (U.S. Patent No. 6,276,632 B1) to allow for a novel method of off-design flow matching, with original test planning conducted under a NASA Small Business Innovative Research study. Data were collected in flight at various off-design Mach numbers for fixed-geometry representations of both the channeled center-body design and an equivalent area smooth center-body design for direct comparison of total pressure recovery and limited distortion measurements.
Walenski, Matthew; Swinney, David
2009-01-01
The central question underlying this study revolves around how children process co-reference relationships—such as those evidenced by pronouns (him) and reflexives (himself)—and how a slowed rate of speech input may critically affect this process. Previous studies of child language processing have demonstrated that typical language developing (TLD) children as young as 4 years of age process co-reference relations in a manner similar to adults on-line. In contrast, off-line measures of pronoun comprehension suggest a developmental delay for pronouns (relative to reflexives). The present study examines dependency relations in TLD children (ages 5–13) and investigates how a slowed rate of speech input affects the unconscious (on-line) and conscious (off-line) parsing of these constructions. For the on-line investigations (using a cross-modal picture priming paradigm), results indicate that at a normal rate of speech TLD children demonstrate adult-like syntactic reflexes. At a slowed rate of speech the typical language developing children displayed a breakdown in automatic syntactic parsing (again, similar to the pattern seen in unimpaired adults). As demonstrated in the literature, our off-line investigations (sentence/picture matching task) revealed that these children performed much better on reflexives than on pronouns at a regular speech rate. However, at the slow speech rate, performance on pronouns was substantially improved, whereas performance on reflexives was not different than at the regular speech rate. We interpret these results in light of a distinction between fast automatic processes (relied upon for on-line processing in real time) and conscious reflective processes (relied upon for off-line processing), such that slowed speech input disrupts the former, yet improves the latter. PMID:19343495
Evaluation of Separation Mechanism Design for the Orion/Ares Launch Vehicle
NASA Technical Reports Server (NTRS)
Konno, Kevin E.; Catalano, Daniel A.; Krivanek, Thomas M.
2008-01-01
As a part of the preliminary design work being performed for the Orion vehicle, the Orion to Spacecraft Adaptor (SA) separation mechanism was analyzed and sized, with findings presented here. Sizing is based on worst case abort condition as a result of an anomaly driving the launch vehicle engine thrust vector control hard-over causing a severe vehicle pitch over. This worst case scenario occurs just before Upper Stage Main Engine Cut-Off (MECO) when the vehicle is the lightest and the damping effect due to propellant slosh has been reduced to a minimum. To address this scenario and others, two modeling approaches were invoked. The first approach was a detailed 2-D (Simulink) model to quickly assess the Service Module Engine nozzle to SA clearance for a given separation mechanism. The second approach involved the generation of an Automatic Dynamic Analysis of Mechanical Systems (ADAMS) model to assess secondary effects due to mass centers of gravity that were slightly off the vehicle centerline. It also captured any interference between the Solar Arrays and the Spacecraft Adapter. A comparison of modeling results and accuracy are discussed. Most notably, incorporating a larger SA flange diameter allowed for a natural separation of the Orion and its engine nozzle even at relatively large pitch rates minimizing the kickoff force. Advantages and disadvantages of the 2-D model vs. a full 3-D (ADAMS) model are discussed as well.
Evaluation of Separation Mechanism Design for the Orion/Ares Launch Vehicle
NASA Technical Reports Server (NTRS)
Konno, Kevin E.; Catalano, Daniel A.; Krivanek, Thomas M.
2008-01-01
As a part of the preliminary design work being performed for the Orion vehicle, the Orion to Spacecraft Adaptor (SA) separation mechanism mechanism was analyzed and sized, with findings presented here. Sizing is based on worst case abort condition as a result of an anomaly driving the launch vehicle engine thrust vector control hard-over causing a severe vehicle pitch over. This worst case scenario occurs just before Upper Stage Main Engine Cut-Off (MECO) when the vehicle is the lightest and the damping effect due to propellant slosh has been reduced to a minimum. To address this scenario and others, two modeling approaches were invoked. The first approach was a detailed Simulink model to quickly assess the Service Module Engine nozzle to SA clearance for a given separation mechanism. The second approach involved the generation of an Automatic Dynamic Analysis of Mechanical Systems (ADAMS) model to assess secondary effects due to mass centers of gravity that were slightly off the vehicle centerline. It also captured any interference between the Solar Arrays and the Spacecraft Adapter. A comparison of modeling results and accuracy are discussed. Most notably, incorporating a larger SA flange diameter allowed for a natural separation of the Orion and its engine nozzle even at relatively large pitch rates minimizing the kickoff force. Advantages and disadvantages of the Simulink model vs. a full geometric ADAMS model are discussed as well.
Evaluation of Separation Mechanism Design for the Orion/Ares Launch Vehicle
NASA Technical Reports Server (NTRS)
Konno, Kevin E.; Catalano, Daniel A.; Krivanek, Thomas M.
2008-01-01
As a part of the preliminary design work being performed for the Orion vehicle, the Orion to Spacecraft Adaptor (SA) separation mechanism was analyzed and sized, with findings presented here. Sizing is based on worst case abort condition as a result of an anomaly driving the launch vehicle engine thrust vector control hard-over causing a severe vehicle pitch over. This worst-case scenario occurs just before Upper Stage Main Engine Cut-Off when the vehicle is the lightest and the damping effect due to propellant slosh has been reduced to a minimum. To address this scenario and others, two modeling approaches were invoked. The first approach was a detailed Simulink model to quickly assess the Service Module Engine nozzle to SA clearance for a given separation mechanism. The second approach involved the generation of an Automatic Dynamic Analysis of Mechanical Systems (ADAMS) model to assess secondary effects due to mass centers of gravity that were slightly off the vehicle centerline. It also captured any interference between the Solar Arrays and the Spacecraft Adapter. A comparison of modeling results and accuracy are discussed. Most notably, incorporating a larger SA flange diameter allowed for a natural separation of the Orion and its engine nozzle even at relatively large pitch rates minimizing the kickoff force. Advantages and disadvantages of the Simulink model vs. a full geometric ADAMS model are discussed as well.
Evaluation of Separation Mechanism Design for the Orion/Ares Launch Vehicle
NASA Technical Reports Server (NTRS)
Konno, Kevin E.; Catalano, Daniel A.; Krivanek, Thomas M.
2008-01-01
As a part of the preliminary design work being performed for the Orion vehicle, the Orion to Spacecraft Adaptor (SA) separation mechanism was analyzed and sized, with findings presented here. Sizing is based on worst case abort condition as a result of an anomaly driving the launch vehicle engine thrust vector control hard-over causing a severe vehicle pitch over. This worst case scenario occurs just before Upper Stage Main Engine Cut-Off (MECO) when the vehicle is the lightest and the damping effect due to propellant slosh has been reduced to a minimum. To address this scenario and others, two modeling approaches were invoked. The first approach was a detailed Simulink model to quickly assess the Service Module Engine nozzle to SA clearance for a given separation mechanism. The second approach involved the generation of an Automatic Dynamic Analysis of Mechanical Systems (ADAMS) model to assess secondary effects due to mass centers of gravity that were slightly off the vehicle centerline. It also captured any interference between the Solar Arrays and the Spacecraft Adapter. A comparison of modeling results and accuracy are discussed. Most notably, incorporating a larger SA flange diameter allowed for a natural separation of the Orion and it's engine nozzle even at relatively large pitch rates minimizing the kickoff force. Advantages and disadvantages of the Simulink model vs. a full geometric ADAMS model are discussed as well.
Serino, Andrea; Sforza, Anna Laura; Kanayama, Noriaki; van Elk, Michiel; Kaliuzhna, Mariia; Herbelin, Bruno; Blanke, Olaf
2015-10-01
Self-face recognition, a hallmark of self-awareness, depends on 'off-line' stored information about one's face and 'on-line' multisensory-motor face-related cues. The brain mechanisms of how on-line sensory-motor processes affect off-line neural self-face representations are unknown. This study used 3D virtual reality to create a 'virtual mirror' in which participants saw an avatar's face moving synchronously with their own face movements. Electroencephalographic (EEG) analysis during virtual mirror exposure revealed mu oscillations in sensory-motor cortex signalling on-line congruency between the avatar's and participants' movements. After such exposure and compatible with a change in their off-line self-face representation, participants were more prone to recognize the avatar's face as their own, and this was also reflected in the activation of face-specific regions in the inferotemporal cortex. Further EEG analysis showed that the on-line sensory-motor effects during virtual mirror exposure caused these off-line visual effects, revealing the brain mechanisms that maintain a coherent self-representation, despite our continuously changing appearance. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
California State Postsecondary Education Commission, Sacramento.
The California Postsecondary Education Commission's (CPEC) analysis of the Sonoma County Junior College District's (SCJCD) proposal to establish a permanent off-campus center in the city of Petaluma is presented in this report. Part I provides background to the proposal, indicating that the SCJCD has operated a temporary center in relocatable…
Near Real-Time Earthquake Exposure and Damage Assessment: An Example from Turkey
NASA Astrophysics Data System (ADS)
Kamer, Yavor; Çomoǧlu, Mustafa; Erdik, Mustafa
2014-05-01
Confined by infamous strike-slip North Anatolian Fault from the north and by the Hellenic subduction trench from the south Turkey is one of the most seismically active countries in Europe. Due this increased exposure and the fragility of the building stock Turkey is among the top countries exposed to earthquake hazard in terms of mortality and economic losses. In this study we focus recent and ongoing efforts to mitigate the earthquake risk in near real-time. We present actual results of recent earthquakes, such as the M6 event off-shore Antalya which occurred on 28 December 2013. Starting at the moment of detection, we obtain a preliminary ground motion intensity distribution based on epicenter and magnitude. Our real-time application is further enhanced by the integration of the SeisComp3 ground motion parameter estimation tool with the Earthquake Loss Estimation Routine (ELER). SeisComp3 provides the online station parameters which are then automatically incorporated into the ShakeMaps produced by ELER. The resulting ground motion distributions are used together with the building inventory to calculate expected number of buildings in various damage states. All these analysis are conducted in an automated fashion and are communicated within a few minutes of a triggering event. In our efforts to disseminate earthquake information to the general public we make extensive use of social networks such as Tweeter and collaborate with mobile phone operators.
Evaluation of COTS Electronic Parts for Extreme Temperature Use in NASA Missions
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad; Elbuluk, Malik
2008-01-01
Electronic systems capable of extreme temperature operation are required for many future NASA space exploration missions where it is desirable to have smaller, lighter, and less expensive spacecraft and probes. Presently, spacecraft on-board electronics are maintained at about room temperature by use of thermal control systems. An Extreme Temperature Electronics Program at the NASA Glenn Research Center focuses on development of electronics suitable for space exploration missions. The effects of exposure to extreme temperatures and thermal cycling are being investigated for commercial-off-the-shelf components as well as for components specially developed for harsh environments. An overview of this program along with selected data is presented.
Chartrand, Tanya L; van Baaren, Rick B; Bargh, John A
2006-02-01
According to the feelings-as-information account, a person's mood state signals to him or her the valence of the current environment (N. Schwarz & G. Clore, 1983). However, the ways in which the environment automatically influences mood in the first place remain to be explored. The authors propose that one mechanism by which the environment influences affect is automatic evaluation, the nonconscious evaluation of environmental stimuli as good or bad. A first experiment demonstrated that repeated brief exposure to positive or negative stimuli (which leads to automatic evaluation) induces a corresponding mood in participants. In 3 additional studies, the authors showed that automatic evaluation affects information processing style. Experiment 4 showed that participants' mood mediates the effect of valenced brief primes on information processing. ((c) 2006 APA, all rights reserved).
Chartrand, Tanya L.; van Baaren, Rick B.; Bargh, John A.
2009-01-01
According to the feelings-as-information account, a person’s mood state signals to him or her the valence of the current environment (N. Schwarz & G. Clore, 1983). However, the ways in which the environment automatically influences mood in the first place remain to be explored. The authors propose that one mechanism by which the environment influences affect is automatic evaluation, the nonconscious evaluation of environmental stimuli as good or bad. A first experiment demonstrated that repeated brief exposure to positive or negative stimuli (which leads to automatic evaluation) induces a corresponding mood in participants. In 3 additional studies, the authors showed that automatic evaluation affects information processing style. Experiment 4 showed that participants’ mood mediates the effect of valenced brief primes on information processing. PMID:16478316
[Investigation of radiation dose for lower tube voltage CT using automatic exposure control].
Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru
2015-04-01
The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.
Automatic control of a negative ion source
NASA Astrophysics Data System (ADS)
Saadatmand, K.; Sredniawski, J.; Solensten, L.
1989-04-01
A CAMAC based control architecture is devised for a Berkeley-type H - volume ion source [1]. The architecture employs three 80386 TM PCs. One PC is dedicated to control and monitoring of source operation. The other PC functions with digitizers to provide data acquisition of waveforms. The third PC is used for off-line analysis. Initially, operation of the source was put under remote computer control (supervisory). This was followed by development of an automated startup procedure. Finally, a study of the physics of operation is now underway to establish a data base from which automatic beam optimization can be derived.
Bidirectional automatic release of reserve for low voltage network made with low capacity PLCs
NASA Astrophysics Data System (ADS)
Popa, I.; Popa, G. N.; Diniş, C. M.; Deaconu, S. I.
2018-01-01
The article presents the design of a bidirectional automatic release of reserve made on two types low capacity programmable logic controllers: PS-3 from Klöckner-Moeller and Zelio from Schneider. It analyses the electronic timing circuits that can be used for making the bidirectional automatic release of reserve: time-on delay circuit and time-off delay circuit (two types). In the paper are present the sequences code for timing performed on the PS-3 PLC, the logical functions for the bidirectional automatic release of reserve, the classical control electrical diagram (with contacts, relays, and time relays), the electronic control diagram (with logical gates and timing circuits), the code (in IL language) made for the PS-3 PLC, and the code (in FBD language) made for Zelio PLC. A comparative analysis will be carried out on the use of the two types of PLC and will be present the advantages of using PLCs.
Burkhardt, Dwight A.; Bartoletti, Theodore M.; Thoreson, Wallace B.
2012-01-01
Receptive field organization of cone-driven bipolar cells was investigated by intracellular recording in the intact light-adapted retina of the tiger salamander (Ambystoma tigrinum). Centered spots and concentric annuli of optimum dimensions were used to selectively stimulate the receptive field center and surround with sinusoidal modulations of contrast at 3 Hz. At low contrasts, responses of both the center and surround of both ON and OFF bipolar cells were linear, showing high gain and thus contrast enhancement relative to cones. The contrast/response curves for the fundamental response, measured by a Fast Fourier Transform, reached half maximum amplitude quickly at 13% contrast followed by saturation at high contrasts. The variation of the normalized amplitude of the center and surround responses was remarkably similar, showing linear regression over the entire response range with very high correlations, r2 = 0.97 for both ON and OFF cells. The contrast/response curves of both center and surround for both ON and OFF cells were well fit (r2 = 0.98) by an equation for single-site binding. In about half the cells studied, the nonlinear waveforms of center and surround could be brought into coincidence by scaling and shifting the surround response in time. This implies that a nonlinearity, common to both center and surround, occurs after polarity inversion at the cone feedback synapse. Evidence from paired whole-cell recordings between single cones and OFF bipolar cells suggests that substantial nonlinearity is not due to transmission at the cone synapse but instead arises from intrinsic bipolar cell and network mechanisms. When sinusoidal contrast modulations were applied to the center and surround simultaneously, clear additivity was observed for small responses in both ON and OFF cells, whereas the interaction was strikingly nonadditive for large responses. The contribution of the surround was then greatly reduced, suggesting attenuation at the cone feedback synapse. PMID:21439110
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, B; Lee, S; Chen, S
Purpose: Monitoring the delivered dose is an important task for the adaptive radiotherapy (ART) and for determining time to re-plan. A software tool which enables automatic delivered dose calculation using cone-beam CT (CBCT) has been developed and tested. Methods: The tool consists of four components: a CBCT Colleting Module (CCM), a Plan Registration Moduel (PRM), a Dose Calculation Module (DCM), and an Evaluation and Action Module (EAM). The CCM is triggered periodically (e.g. every 1:00 AM) to search for newly acquired CBCTs of patients of interest and then export the DICOM files of the images and related registrations defined inmore » ARIA followed by triggering the PRM. The PRM imports the DICOM images and registrations, links the CBCTs to the related treatment plan of the patient in the planning system (RayStation V4.5, RaySearch, Stockholm, Sweden). A pre-determined CT-to-density table is automatically generated for dose calculation. Current version of the DCM uses a rigid registration which regards the treatment isocenter of the CBCT to be the isocenter of the treatment plan. Then it starts the dose calculation automatically. The AEM evaluates the plan using pre-determined plan evaluation parameters: PTV dose-volume metrics and critical organ doses. The tool has been tested for 10 patients. Results: Automatic plans are generated and saved in the order of the treatment dates of the Adaptive Planning module of the RayStation planning system, without any manual intervention. Once the CTV dose deviates more than 3%, both email and page alerts are sent to the physician and the physicist of the patient so that one can look the case closely. Conclusion: The tool is capable to perform automatic dose tracking and to alert clinicians when an action is needed. It is clinically useful for off-line adaptive therapy to catch any gross error. Practical way of determining alarming level for OAR is under development.« less
ERIC Educational Resources Information Center
Perlman, Michal; Fletcher, Brooke A.
2012-01-01
Research Findings: The amount and quality of communication between staff and guardians in child care centers was examined using extensive naturalistic observations. Interactions between staff and more than 1,000 guardians who dropped their child off at their child care center were captured through a series of 20-s time-sampled observations.…
Meeker, John D; Cooper, Michael R; Lefkowitz, Daniel; Susi, Pam
2009-01-01
A number of tasks in construction generate worker overexposures to respirable crystalline silica dust, which is a significant contributor to occupational mortality and morbidity. This study evaluated the performance of commercially available engineering controls used in dusty construction tasks commonly performed by bricklayers. Local exhaust ventilation (LEV) controls for a portable abrasive cutter and for tuckpointing grinders were examined at a bricklayers' training center, as were two stationary wet saws. Personal breathing zone air samples were collected with and without the use of LEV or water suppression during simulated concrete block cutting, brick cutting, and tuckpointing. Compared with the use of no exposure control during block and brick cutting, the portable LEV unit significantly reduced mean respirable quartz exposures by 96% for block cutting and 91% for brick cutting (p < 0.01). The use of stationary wet saws was also associated with 91% reductions in exposure (p < 0.01). For tuckpointing, the reductions in mean respirable quartz concentrations were between 91% and 93% with the LEV controls (p < 0.05). Reductions of up to 96% in mean respirable quartz concentration were observed between control and no-control scenarios. These reductions with commercially available off-the-shelf tools demonstrate the effectiveness of engineering control interventions to reduce crystalline silica exposures in construction. Strategies to further improve control performance and approaches for increasing control interventions in construction are needed.
Evans, David V; Keys, Toby; Desnick, Laurel; A Andrilla, C Holly; Bienz, Danielle; Rosenblatt, Roger
2016-07-01
Pharmaceutical marketing techniques are effective in changing the behavior of health care providers in ways that deviate from evidence-based practices. To mitigate the influence of pharmaceutical marketing on learners, academic medical centers (AMCs) have adopted policies to limit student/industry interaction. Many clinical experiences occur outside of the AMC. The purpose of this study was to compare medical students' exposure to pharmaceutical marketing in off-campus rural and urban underserved clinical sites. The University of Washington School of Medicine Rural and Underserved Opportunities Program (RUOP) places rising second-year medical students in underserved clinical sites in five northwestern states. We surveyed RUOP students to evaluate their exposure to pharmaceutical marketing. Of 120 students, 86 (72%) completed surveys. Sixty-five (76%) did their RUOP rotation in rural areas. Students in rural locations were more likely to report exposure to pharmaceutical marketing. Distribution of free drug samples was reportedly three times higher in rural than urban sites (54% versus 15%). Doctors meeting with sales representatives were reported as four times higher in rural clinics (40% versus 10%). Students at rural sites reported exposure to pharmaceutical marketing more than those in urban settings. Rural medical educators should provide faculty development for community clinicians on the influences of pharmaceutical marketing on learners. Medical schools must review local clinic and institution-wide policies to limit pharmaceutical marketing exposure to learners in the rural learning environment.
Deng, Shijie; Morrison, Alan P
2012-09-15
This Letter presents an active quench-and-reset circuit for Geiger-mode avalanche photodiodes (GM-APDs). The integrated circuit was fabricated using a conventional 0.35 μm complementary metal oxide semiconductor process. Experimental results show that the circuit is capable of linearly setting the hold-off time from several nanoseconds to microseconds with a resolution of 6.5 ns. This allows the selection of the optimal afterpulse-free hold-off time for the GM-APD via external digital inputs or additional signal processing circuitry. Moreover, this circuit resets the APD automatically following the end of the hold-off period, thus simplifying the control for the end user. Results also show that a minimum dead time of 28.4 ns is achieved, demonstrating a saturated photon-counting rate of 35.2 Mcounts/s.
Combating Terrorism Technology Support Office 2006 Review
2006-01-01
emplaced beyond the control point, activated manually or automatically , with warning lights and an audible alarm to alert innocent pedestrians. The...throughout a vehicle. When a tamper event is detected, SERVANT automatically records sensor data and surveillance video and sends an alert to the security...exposure to organophosphate nerve agents, botulinum toxin, cyanide, and carbon monoxide and will be packaged into a portable , lightweight, mobile hand
1991-12-05
second overshoot. Automatic steering was turned off for 9 days following the initial undershoot ( 48120 to 48129) and turned off from 48160 to the end...35780 0.08 A A 0.04 AA A A A35776 AA A A A AA A A A AL’ AA I- A 12 ,- U.U A __,, 0.00 . A A k 35772 I I I I I I -0.04 48000 48030 48060 48090 48120
Huang, Jiang; Carpenter, Joshua H.; Li, Chang -Zhi; ...
2015-12-02
A novel, yet simple solution fabrication technique to address the trade-off between photocurrent and fill factor in thick bulk heterojunction organic solar cells is described. Lastly, the inverted off-center spinning technique promotes a vertical gradient of the donor–acceptor phase-separated morphology, enabling devices with near 100% internal quantum efficiency and a high power conversion efficiency of 10.95%.
WOLF; automatic typing program
Evenden, G.I.
1982-01-01
A FORTRAN IV program for the Hewlett-Packard 1000 series computer provides for automatic typing operations and can, when employed with manufacturer's text editor, provide a system to greatly facilitate preparation of reports, letters and other text. The input text and imbedded control data can perform nearly all of the functions of a typist. A few of the features available are centering, titles, footnotes, indentation, page numbering (including Roman numerals), automatic paragraphing, and two forms of tab operations. This documentation contains both user and technical description of the program.
NASA Technical Reports Server (NTRS)
Hueschen, R. M.
1986-01-01
Five flight tests of the Digital Automated Landing System (DIALS) were conducted on the Advanced Transport Operating Systems (ATOPS) Transportation Research Vehicle (TSRV) -- a modified Boeing 737 aircraft for advanced controls and displays research. These flight tests were conducted at NASA's Wallops Flight Center using the microwave landing system (MLS) installation on runway 22. This report describes the flight software equations of the DIALS which was designed using modern control theory direct-digital design methods and employed a constant gain Kalman filter. Selected flight test performance data is presented for localizer (runway centerline) capture and track at various intercept angles, for glideslope capture and track of 3, 4.5, and 5 degree glideslopes, for the decrab maneuver, and for the flare maneuver. Data is also presented to illustrate the system performance in the presence of cross, gust, and shear winds. The mean and standard deviation of the peak position errors for localizer capture were, respectively, 24 feet and 26 feet. For mild wind conditions, glideslope and localizer tracking position errors did not exceed, respectively, 5 and 20 feet. For gusty wind conditions (8 to 10 knots), these errors were, respectively, 10 and 30 feet. Ten hands off automatic lands were performed. The standard deviation of the touchdown position and velocity errors from the mean values were, respectively, 244 feet and 0.7 feet/sec.
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.
2017-03-01
Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.
76 FR 4443 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... located nearby. The computer room is protected by an automatic sprinkler system, automatic sensors (e.g... 1974; Report of Modified or Altered System of Records AGENCY: National Center for HIV, STD and TB... Services (DHHS). ACTION: Notification of Proposed Altered System of Records. SUMMARY: The Department of...
29 CFR 1926.803 - Compressed air.
Code of Federal Regulations, 2011 CFR
2011-07-01
... working chamber is below 12 p.s.i.g., each man lock shall be equipped with automatic controls which... also be equipped with manual controls to permit the lock attendant to override the automatic mechanism... be in a cramped position, and shall not have less than 5 feet clear head room at the center and a...
Automatic Gain Control in Compact Spectrometers.
Protopopov, Vladimir
2016-03-01
An image intensifier installed in the optical path of a compact spectrometer may act not only as a fast gating unit, which is widely used for time-resolved measurements, but also as a variable attenuator-amplifier in a continuous wave mode. This opens the possibility of an automatic gain control, a new feature in spectroscopy. With it, the user is relieved from the necessity to manually adjust signal level at a certain value that it is done automatically by means of an electronic feedback loop. It is even more important that automatic gain control is done without changing exposure time, which is an additional benefit in time-resolved experiments. The concept, algorithm, design considerations, and experimental results are presented. © The Author(s) 2016.
An automatic system to study sperm motility and energetics
Nascimento, Jaclyn M.; Chandsawangbhuwana, Charlie; Botvinick, Elliot L.; Berns, Michael W.
2012-01-01
An integrated robotic laser and microscope system has been developed to automatically analyze individual sperm motility and energetics. The custom-designed optical system directs near-infrared laser light into an inverted microscope to create a single-point 3-D gradient laser trap at the focal spot of the microscope objective. A two-level computer structure is described that quantifies the sperm motility (in terms of swimming speed and swimming force) and energetics (measuring mid-piece membrane potential) using real-time tracking (done by the upper-level system) and fluorescent ratio imaging (done by the lower-level system). The communication between these two systems is achieved by a gigabit network. The custom-built image processing algorithm identifies the sperm swimming trajectory in real-time using phase contrast images, and then subsequently traps the sperm by automatically moving the microscope stage to relocate the sperm to the laser trap focal plane. Once the sperm is stably trapped (determined by the algorithm), the algorithm can also gradually reduce the laser power by rotating the polarizer in the laser path to measure the trapping power at which the sperm is capable of escaping the trap. To monitor the membrane potential of the mitochondria located in a sperm’s mid-piece, the sperm is treated with a ratiometrically-encoded fluorescent probe. The proposed algorithm can relocate the sperm to the center of the ratio imaging camera and the average ratio value can be measured in real-time. The three parameters, sperm escape power, sperm swimming speed and ratio values of the mid-piece membrane potential of individual sperm can be compared with respect to time. This two-level automatic system to study individual sperm motility and energetics has not only increased experimental throughput by an order of magnitude but also has allowed us to monitor sperm energetics prior to and after exposure to the laser trap. This system should have application in both the human fertility clinic and in animal husbandry. PMID:18299996
An automatic system to study sperm motility and energetics.
Shi, Linda Z; Nascimento, Jaclyn M; Chandsawangbhuwana, Charlie; Botvinick, Elliot L; Berns, Michael W
2008-08-01
An integrated robotic laser and microscope system has been developed to automatically analyze individual sperm motility and energetics. The custom-designed optical system directs near-infrared laser light into an inverted microscope to create a single-point 3-D gradient laser trap at the focal spot of the microscope objective. A two-level computer structure is described that quantifies the sperm motility (in terms of swimming speed and swimming force) and energetics (measuring mid-piece membrane potential) using real-time tracking (done by the upper-level system) and fluorescent ratio imaging (done by the lower-level system). The communication between these two systems is achieved by a gigabit network. The custom-built image processing algorithm identifies the sperm swimming trajectory in real-time using phase contrast images, and then subsequently traps the sperm by automatically moving the microscope stage to relocate the sperm to the laser trap focal plane. Once the sperm is stably trapped (determined by the algorithm), the algorithm can also gradually reduce the laser power by rotating the polarizer in the laser path to measure the trapping power at which the sperm is capable of escaping the trap. To monitor the membrane potential of the mitochondria located in a sperm's mid-piece, the sperm is treated with a ratiometrically-encoded fluorescent probe. The proposed algorithm can relocate the sperm to the center of the ratio imaging camera and the average ratio value can be measured in real-time. The three parameters, sperm escape power, sperm swimming speed and ratio values of the mid-piece membrane potential of individual sperm can be compared with respect to time. This two-level automatic system to study individual sperm motility and energetics has not only increased experimental throughput by an order of magnitude but also has allowed us to monitor sperm energetics prior to and after exposure to the laser trap. This system should have application in both the human fertility clinic and in animal husbandry.
Research and Development of Fully Automatic Alien Smoke Stack and Packaging System
NASA Astrophysics Data System (ADS)
Yang, Xudong; Ge, Qingkuan; Peng, Tao; Zuo, Ping; Dong, Weifu
2017-12-01
The problem of low efficiency of manual sorting packaging for the current tobacco distribution center, which developed a set of safe efficient and automatic type of alien smoke stack and packaging system. The functions of fully automatic alien smoke stack and packaging system adopt PLC control technology, servo control technology, robot technology, image recognition technology and human-computer interaction technology. The characteristics, principles, control process and key technology of the system are discussed in detail. Through the installation and commissioning fully automatic alien smoke stack and packaging system has a good performance and has completed the requirements for shaped cigarette.
Automatic Operation For A Robot Lawn Mower
NASA Astrophysics Data System (ADS)
Huang, Y. Y.; Cao, Z. L.; Oh, S. J.; Kattan, E. U.; Hall, E. L.
1987-02-01
A domestic mobile robot, lawn mower, which performs the automatic operation mode, has been built up in the Center of Robotics Research, University of Cincinnati. The robot lawn mower automatically completes its work with the region filling operation, a new kind of path planning for mobile robots. Some strategies for region filling of path planning have been developed for a partly-known or a unknown environment. Also, an advanced omnidirectional navigation system and a multisensor-based control system are used in the automatic operation. Research on the robot lawn mower, especially on the region filling of path planning, is significant in industrial and agricultural applications.
Predicting Return of Fear Following Exposure Therapy With an Implicit Measure of Attitudes
Vasey, Michael W.; Harbaugh, Casaundra N.; Buffington, Adam G.; Jones, Christopher R.; Fazio, Russell H.
2012-01-01
We sought to advance understanding of the processes underlying the efficacy of exposure therapy and particularly the phenomenon of return of fear (ROF) following treatment by drawing on a social psychological view of phobias as attitudes. Specifically, a dual process theory of attitude-related behavior predicts that a positive response to exposure therapy may reflect change in either the automatic (the attitude representation itself) or controlled (skills and confidence at coping with the fear) responses to the phobic stimulus, or both. However, if the attitude representation remains negative following treatment, ROF should be more likely. We tested this hypothesis in a clinical sample of individuals with public speaking phobia using a single-session exposure therapy protocol previously shown to be efficacious but also associated with some ROF. Consistent with predictions, a post-treatment implicit measure of attitudes toward public speaking (the Personalized Implicit Association Test [PIAT]) predicted ROF at 1-month follow-up. These results suggest that change in the automatically activated attitude toward the phobic stimulus is an important goal of exposure therapy and that an implicit measure like the PIAT can provide a useful measure of such change by which to gauge the adequacy of exposure treatment and predict its long-term efficacy. PMID:23085186
Are we living near the center of a local void?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cusin, Giulia; Pitrou, Cyril; Uzan, Jean-Philippe, E-mail: giulia.cusin@unige.ch, E-mail: pitrou@iap.fr, E-mail: uzan@iap.fr
The properties of the cosmic microwave background (CMB) temperature and polarisation anisotropies measured by a static, off-centered observer located in a local spherically symmetric void, are described. In particular in this paper we compute, together with the standard 2-point angular correlation functions, the off-diagonal correlators, which are no more vanishing by symmetry. While the energy shift induced by the off-centered position of the observer can be suppressed by a proper choice of the observer velocity, a lensing-like effect on the CMB emission point remains. This latter effect is genuinely geometrical (e.g. non-degenerate with a boost) and reflects in the structuremore » of the off-diagonal correlators. At lowest order in this effect, the temperature and polarisation correlation matrices have non-vanishing diagonal elements, as usual, and all the off-diagonal terms are excited. This particular signature of a local void model allows one, in principle, to disentangle geometrical effects from local kinematical ones in CMB observations.« less
Automatic measurement of skin textures of the dorsal hand in evaluating skin aging.
Gao, Qian; Yu, Jiaming; Wang, Fang; Ge, Tiantian; Hu, Liwen; Liu, Yang
2013-05-01
Changes in skin textures have been used to evaluate skin aging in many studies. In our previous study, we built some skin texture parameters, which can be used to evaluate skin aging of human dorsal hand. However, it will take too much time and need to work arduously to get the information from digital skin image by manual work. So, we want to build a simple and effective method to automatically count some of those skin texture parameters by using digital image-processing technology. A total of 100 subjects aged 30 years and above were involved. Sun exposure history and demographic information were collected by using a questionnaire. The skin image of subjects' dorsal hand was obtained by using a portable skin detector. The number of grids, which is one of skin texture parameters built in our previous study, was measured manually and automatically. Automated image analysis program was developed by using Matlab 7.1 software. The number of grids counted automatically (NGA) was significantly correlated with the number of grids counted manually (NGM) (r = 0.9287, P < 0.0001). And in each age group, there were no significant differences between NGA and NGM. The NGA was negatively correlated with age and lifetime sun exposure, and decreased with increasing Beagley-Gibson score from 3 to 6. In addition, even after adjusting for NGA, the standard deviation of grid areas for each image was positively correlated with age, sun exposure, and Bealey-Gibson score. The method introduced in present study can be used to measure some skin aging parameters automatically and objectively. And it will save much time, reduce labor, and avoid measurement errors of deferent investigators when evaluating a great deal of skin images in a short time. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
First photometric properties of Dome C, Antarctica
NASA Astrophysics Data System (ADS)
Chadid, M.; Vernin, J.; Jeanneaux, F.; Mekarnia, D.; Trinquet, H.
2008-07-01
Here we present the first photometric extinction measurements in the visible range performed at Dome C in Antarctica, using PAIX photometer (Photometer AntarctIca eXtinction). It is made with "off the shelf" components, Audine camera at the focus of Blazhko telescope, a Meade M16 diaphragmed down to 15 cm. For an exposure time of 60 s without filter, a 10th V-magnitude star is measured with a precision of 1/100 mag. A first statistics over 16 nights in August 2007 leads to a 0.5 magnitude per air mass extinction, may be due to high altitude cirrus. This rather simple experiment shows that continuous observations can be performed at Dome C, allowing high frequency resolution on pulsation and asteroseismology studies. Light curves of one of RR Lyrae stars: SAra were established. They show the typical trend of a RRLyrae star. A recent sophisticated photometer, PAIX II, has been installed recently at Dome C during polar summer 2008, with a ST10 XME camera, automatic guiding, auto focusing and Johnson/Bessel UBVRI filter wheels.
9 CFR 307.7 - Safety requirements for electrical stimulating (EST) equipment.
Code of Federal Regulations, 2011 CFR
2011-01-01
... beam sensors form the enclosure, the stimulating equipment shall be automatically shut off when the sensor signals are broken. (3) Mandatory Warning Devices and Signals. The following warning devices or.... (ii) An ANSI Z53.1-Color Code sign reading (a) “Danger Electrical Hazard” for stimulating voltage...
9 CFR 307.7 - Safety requirements for electrical stimulating (EST) equipment.
Code of Federal Regulations, 2010 CFR
2010-01-01
... beam sensors form the enclosure, the stimulating equipment shall be automatically shut off when the sensor signals are broken. (3) Mandatory Warning Devices and Signals. The following warning devices or.... (ii) An ANSI Z53.1-Color Code sign reading (a) “Danger Electrical Hazard” for stimulating voltage...
Conceptual apparatus for detecting leaks of nonconductive liquids
NASA Technical Reports Server (NTRS)
Walsh, G. D.
1968-01-01
Apparatus detects leaks at joints in lines carrying electrically nonconductive liquids. The proposed apparatus could include a panel that would give a visual or audible indication of a leak /to permit manual shutdown/ and/or an electromechanical actuator that would automatically cut off the flow when a leak occurs.
Development of an Automatic Dispensing System for Traditional Chinese Herbs.
Lin, Chi-Ying; Hsieh, Ping-Jung
2017-01-01
The gathering of ingredients for decoctions of traditional Chinese herbs still relies on manual dispensation, due to the irregular shape of many items and inconsistencies in weights. In this study, we developed an automatic dispensing system for Chinese herbal decoctions with the aim of reducing manpower costs and the risk of mistakes. We employed machine vision in conjunction with a robot manipulator to facilitate the grasping of ingredients. The name and formulation of the decoction are input via a human-computer interface, and the dispensing of multiple medicine packets is performed automatically. An off-line least-squared curve fitting method was used to calculate the amount of material grasped by the claws and thereby improve system efficiency as well as the accuracy of individual dosages. Experiments on the dispensing of actual ingredients demonstrate the feasibility of the proposed system.
A Practical Approach To Lift-Off
NASA Astrophysics Data System (ADS)
Jones, Susan K.; Chapman, Richard C.; Pavelchek, Edward K.
1987-08-01
Lift-off technology provides an alternate metal patterning technology to that of subtractive etching. In this raper, we describe an image reversal process which provides a practical means for reliably producing resist stencils which are required for successful lift-off in a 2.0 μm metal pitch CMOS process, as well as for experimental submicron processing. Experimental data and PROSIM simulations are presented to show the effects of patterning exposure dose, flood exposure dose, develop time, and focus parameters on resist linewidths as well as for control of resist retrograde (undercut) sidewall angles. Deposition and subsequent lift-off of Al/Cu alloys and sandwich metallizations is demonstrated. Because the image reversal process enables pattern definition at the top of the resist film, it is demonstrated that thicker resist films can be used to produce finer resolution of lift-off stencils over topography than would have been expected without resorting to multilayer resist structures.
Sahoo, Satya S.; Ogbuji, Chimezie; Luo, Lingyun; Dong, Xiao; Cui, Licong; Redline, Susan S.; Zhang, Guo-Qiang
2011-01-01
Clinical studies often use data dictionaries with controlled sets of terms to facilitate data collection, limited interoperability and sharing at a local site. Multi-center retrospective clinical studies require that these data dictionaries, originating from individual participating centers, be harmonized in preparation for the integration of the corresponding clinical research data. Domain ontologies are often used to facilitate multi-center data integration by modeling terms from data dictionaries in a logic-based language, but interoperability among domain ontologies (using automated techniques) is an unresolved issue. Although many upper-level reference ontologies have been proposed to address this challenge, our experience in integrating multi-center sleep medicine data highlights the need for an upper level ontology that models a common set of terms at multiple-levels of abstraction, which is not covered by the existing upper-level ontologies. We introduce a methodology underpinned by a Minimal Domain of Discourse (MiDas) algorithm to automatically extract a minimal common domain of discourse (upper-domain ontology) from an existing domain ontology. Using the Multi-Modality, Multi-Resource Environment for Physiological and Clinical Research (Physio-MIMI) multi-center project in sleep medicine as a use case, we demonstrate the use of MiDas in extracting a minimal domain of discourse for sleep medicine, from Physio-MIMI’s Sleep Domain Ontology (SDO). We then extend the resulting domain of discourse with terms from the data dictionary of the Sleep Heart and Health Study (SHHS) to validate MiDas. To illustrate the wider applicability of MiDas, we automatically extract the respective domains of discourse from 6 sample domain ontologies from the National Center for Biomedical Ontologies (NCBO) and the OBO Foundry. PMID:22195180
Sahoo, Satya S; Ogbuji, Chimezie; Luo, Lingyun; Dong, Xiao; Cui, Licong; Redline, Susan S; Zhang, Guo-Qiang
2011-01-01
Clinical studies often use data dictionaries with controlled sets of terms to facilitate data collection, limited interoperability and sharing at a local site. Multi-center retrospective clinical studies require that these data dictionaries, originating from individual participating centers, be harmonized in preparation for the integration of the corresponding clinical research data. Domain ontologies are often used to facilitate multi-center data integration by modeling terms from data dictionaries in a logic-based language, but interoperability among domain ontologies (using automated techniques) is an unresolved issue. Although many upper-level reference ontologies have been proposed to address this challenge, our experience in integrating multi-center sleep medicine data highlights the need for an upper level ontology that models a common set of terms at multiple-levels of abstraction, which is not covered by the existing upper-level ontologies. We introduce a methodology underpinned by a Minimal Domain of Discourse (MiDas) algorithm to automatically extract a minimal common domain of discourse (upper-domain ontology) from an existing domain ontology. Using the Multi-Modality, Multi-Resource Environment for Physiological and Clinical Research (Physio-MIMI) multi-center project in sleep medicine as a use case, we demonstrate the use of MiDas in extracting a minimal domain of discourse for sleep medicine, from Physio-MIMI's Sleep Domain Ontology (SDO). We then extend the resulting domain of discourse with terms from the data dictionary of the Sleep Heart and Health Study (SHHS) to validate MiDas. To illustrate the wider applicability of MiDas, we automatically extract the respective domains of discourse from 6 sample domain ontologies from the National Center for Biomedical Ontologies (NCBO) and the OBO Foundry.
Automatic processing of induced events in the geothermal reservoirs Landau and Insheim, Germany
NASA Astrophysics Data System (ADS)
Olbert, Kai; Küperkoch, Ludger; Meier, Thomas
2016-04-01
Induced events can be a risk to local infrastructure that need to be understood and evaluated. They represent also a chance to learn more about the reservoir behavior and characteristics. Prior to the analysis, the waveform data must be processed consistently and accurately to avoid erroneous interpretations. In the framework of the MAGS2 project an automatic off-line event detection and a phase onset time determination algorithm are applied to induced seismic events in geothermal systems in Landau and Insheim, Germany. The off-line detection algorithm works based on a cross-correlation of continuous data taken from the local seismic network with master events. It distinguishes events between different reservoirs and within the individual reservoirs. Furthermore, it provides a location and magnitude estimation. Data from 2007 to 2014 are processed and compared with other detections using the SeisComp3 cross correlation detector and a STA/LTA detector. The detected events are analyzed concerning spatial or temporal clustering. Furthermore the number of events are compared to the existing detection lists. The automatic phase picking algorithm combines an AR-AIC approach with a cost function to find precise P1- and S1-phase onset times which can be used for localization and tomography studies. 800 induced events are processed, determining 5000 P1- and 6000 S1-picks. The phase onset times show a high precision with mean residuals to manual phase picks of 0s (P1) to 0.04s (S1) and standard deviations below ±0.05s. The received automatic picks are applied to relocate a selected number of events to evaluate influences on the location precision.
Passive gas-gap heat switch for adiabatic demagnetization refrigerator
NASA Technical Reports Server (NTRS)
Shirron, Peter J. (Inventor); Di Pirro, Michael J. (Inventor)
2005-01-01
A passive gas-gap heat switch for use with a multi-stage continuous adiabatic demagnetization refrigerator (ADR). The passive gas-gap heat switch turns on automatically when the temperature of either side of the switch rises above a threshold value and turns off when the temperature on either side of the switch falls below this threshold value. One of the heat switches in this multistage process must be conductive in the 0.25? K to 0.3? K range. All of the heat switches must be capable of switching off in a short period of time (1-2 minutes), and when off to have a very low thermal conductance. This arrangement allows cyclic cooling cycles to be used without the need for separate heat switch controls.
32 CFR Appendix D to Subpart M of... - Unauthorized Activities in Maneuver Training Areas
Code of Federal Regulations, 2013 CFR
2013-07-01
... Lewis: Civilian paramilitary activities and combat games. Off-pavement motorcycle riding. Off-road... of alcoholic beverages. 2. Yakima Training Center: Civilian paramilitary activities and combat games... combat games. Off-pavement motorcycle riding. Off-road vehicle operation. Hang gliding. Ultralight...
32 CFR Appendix D to Subpart M of... - Unauthorized Activities in Maneuver Training Areas
Code of Federal Regulations, 2012 CFR
2012-07-01
... Lewis: Civilian paramilitary activities and combat games. Off-pavement motorcycle riding. Off-road... of alcoholic beverages. 2. Yakima Training Center: Civilian paramilitary activities and combat games... combat games. Off-pavement motorcycle riding. Off-road vehicle operation. Hang gliding. Ultralight...
32 CFR Appendix D to Subpart M of... - Unauthorized Activities in Maneuver Training Areas
Code of Federal Regulations, 2014 CFR
2014-07-01
... Lewis: Civilian paramilitary activities and combat games. Off-pavement motorcycle riding. Off-road... of alcoholic beverages. 2. Yakima Training Center: Civilian paramilitary activities and combat games... combat games. Off-pavement motorcycle riding. Off-road vehicle operation. Hang gliding. Ultralight...
3D-Printed Detector Band for Magnetic Off-Plane Flux Measurements in Laminated Machine Cores
Pfützner, Helmut; Palkovits, Martin; Windischhofer, Andreas; Giefing, Markus
2017-01-01
Laminated soft magnetic cores of transformers, rotating machines etc. may exhibit complex 3D flux distributions with pronounced normal fluxes (off-plane fluxes), perpendicular to the plane of magnetization. As recent research activities have shown, detections of off-plane fluxes tend to be essential for the optimization of core performances aiming at a reduction of core losses and of audible noise. Conventional sensors for off-plane flux measurements tend to be either of high thickness, influencing the measured fluxes significantly, or require laborious preparations. In the current work, thin novel detector bands for effective and simple off-plane flux detections in laminated machine cores were manufactured. They are printed in an automatic way by an in-house developed 3D/2D assembler. The latter enables a unique combination of conductive and non-conductive materials. The detector bands were effectively tested in the interior of a two-package, three-phase model transformer core. They proved to be mechanically resilient, even for strong clamping of the core. PMID:29257063
3D-Printed Detector Band for Magnetic Off-Plane Flux Measurements in Laminated Machine Cores.
Shilyashki, Georgi; Pfützner, Helmut; Palkovits, Martin; Windischhofer, Andreas; Giefing, Markus
2017-12-19
Laminated soft magnetic cores of transformers, rotating machines etc. may exhibit complex 3D flux distributions with pronounced normal fluxes (off-plane fluxes), perpendicular to the plane of magnetization. As recent research activities have shown, detections of off-plane fluxes tend to be essential for the optimization of core performances aiming at a reduction of core losses and of audible noise. Conventional sensors for off-plane flux measurements tend to be either of high thickness, influencing the measured fluxes significantly, or require laborious preparations. In the current work, thin novel detector bands for effective and simple off-plane flux detections in laminated machine cores were manufactured. They are printed in an automatic way by an in-house developed 3D/2D assembler. The latter enables a unique combination of conductive and non-conductive materials. The detector bands were effectively tested in the interior of a two-package, three-phase model transformer core. They proved to be mechanically resilient, even for strong clamping of the core.
Machine-Aided Indexing in Practice: An Encounter with Automatic Indexing of the Third Kind.
ERIC Educational Resources Information Center
Klingbiel, Paul H.
This three-part report includes a brief history of the Defense Documentation Center (DDC) with a description of the collections and their accessibility; categorization of automatic indexing into three kinds with a brief description of the DDC system of machine-aided indexing; and an indication of some operational experiences with the system.…
Fatigue life analysis of cracked gas receiver of emergency cut-off system in gas gathering station
NASA Astrophysics Data System (ADS)
Hu, Junzhi; Zhou, Jiyong; Li, Siyuan
2017-06-01
Small-scale air compressor and gas receiver are used as the driving gas of the emergency cut-off system in gas gathering station. Operation of block valve is ensured by starting and stopping compressor automatically. The frequent start-stop of compressor and the pressure fluctuation pose a threat to the service life of gas receiver, and then affect normal operation of the emergency cut-off system and security of gas gathering station. In this paper, the fatigue life of a pressure vessel with axial semi-elliptical surface crack in the inner wall is analyzed under the varying pressure by means of the theory of fracture mechanics. The influences of the amplitude of pressure fluctuation and the initial crack size on the residual life of gas receiver are discussed. It provides a basis for setting the working parameters of gas receiver of emergency cut-off system and determining the maintenance cycle.
Modeling Off-Nominal Behavior in SysML
NASA Technical Reports Server (NTRS)
Day, John C.; Donahue, Kenneth; Ingham, Michel; Kadesch, Alex; Kennedy, Andrew K.; Post, Ethan
2012-01-01
Specification and development of fault management functionality in systems is performed in an ad hoc way - more of an art than a science. Improvements to system reliability, availability, safety and resilience will be limited without infusion of additional formality into the practice of fault management. Key to the formalization of fault management is a precise representation of off-nominal behavior. Using the upcoming Soil Moisture Active-Passive (SMAP) mission for source material, we have modeled the off-nominal behavior of the SMAP system during its initial spin-up activity, using the System Modeling Language (SysML). In the course of developing these models, we have developed generic patterns for capturing off-nominal behavior in SysML. We show how these patterns provide useful ways of reasoning about the system (e.g., checking for completeness and effectiveness) and allow the automatic generation of typical artifacts (e.g., success trees and FMECAs) used in system analyses.
Automatic Radiated Susceptibility Test System for Payload Equipment
NASA Technical Reports Server (NTRS)
Ngo, Hoai T.; Sturman, John C.; Sargent, Noel B.
1995-01-01
An automatic radiated susceptibility test system (ARSTS) was developed for NASA Lewis Research Center's Electro-magnetic Interference laboratory. According to MSFC-SPEC 521B, any electrical or electronic equipment that will be transported by the spacelab and space shuttle must be tested for susceptibility to electromagnetic interference. This state-of-the-art automatic test system performs necessary calculations; analyzes, processes, and records a great quantity of measured data; and monitors the equipment being tested in real-time and with minimal user intervention. ARSTS reduces costly test time, increases test accuracy, and provides reliable test results.
[Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].
Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun
2016-01-01
To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.
NASA Astrophysics Data System (ADS)
Takaya, Masaaki; Honda, Hiroyasu; Narita, Yoshihiro; Yamamoto, Fumihiko; Arakawa, Koji
2006-04-01
We report on a newly developed in-service measurement technique that can be used from a central office to find and identify any filter in front of an ONU on an optical fiber access network. Using this system, in-service tests can be performed because the test lights are modulated at a high frequency. Moreover, by using the equipment we developed, this confirmation operation can be performed continuously and automatically with existing automatic fiber testing systems. The developed technique is effective for constructing a fiber line testing system with an optical time domain reflectometer.
2001-05-08
NASA's modified Boeing 747 Shuttle Carrier Aircraft with the Space Shuttle Endeavour on top lifts off from Edwards Air Force Base to begin its ferry flight back to the Kennedy Space Center in Florida.
Employer-Sponsored Child Care Models and Related Issues.
ERIC Educational Resources Information Center
Renfroe, Martha Lou
This study was designed to describe the different models of Employer-Sponsored Child Care (ESCC) available to employers and child care professionals. Examples of specific child care programs sponsored by employers are described, and five ESCC models are identified: on-site and off-site centers for a single employer, off-site centers for multiple…
Behavioral responses of north American Elk to recreational activity
Naylor, L.M.; Wisdom, M.J.; Anthony, R.G.
2009-01-01
Off-road recreation on public lands in North America has increased dramatically in recent years. Wild ungulates are sensitive to human activities, but the effect of off-road recreation, both motorized and nonmotorized, is poorly understood. We measured responses of elk (Cervus elaphus) to recreational disturbance in northeast Oregon, USA, from April to October, 2003 and 2004. We subjected elk to 4 types of recreational disturbance: all-terrain vehicle (ATV) riding, mountain biking, hiking, and horseback riding. Motion sensors inside radiocollars worn by 13 female elk recorded resting, feeding, and travel activities at 5-minute intervals throughout disturbance and control periods. Elk fed and rested during control periods, with little time spent traveling. Travel time increased in response to all 4 disturbances and was highest in mornings. Elk travel time was highest during ATV exposure, followed by exposure to mountain biking, hiking, and horseback riding. Feeding time decreased during ATV exposure and resting decreased when we subjected elk to mountain biking and hiking disturbance in 2003. Our results demonstrated that activities of elk can be substantially affected by off-road recreation. Mitigating these effects may be appropriate where elk are a management priority. Balancing management of species like elk with off-road recreation will become increasingly important as off-road recreational uses continue to increase on public lands in North America.
Large-field high-resolution mosaic movies
NASA Astrophysics Data System (ADS)
Hammerschlag, Robert H.; Sliepen, Guus; Bettonvil, Felix C. M.; Jägers, Aswin P. L.; Sütterlin, Peter; Martin, Sara F.
2012-09-01
Movies with fields-of-view larger than normal for high-resolution telescopes will give a better understanding of processes on the Sun, such as filament and active region developments and their possible interactions. New active regions can influence, by their emergence, their environment to the extent of possibly serving as an igniter of the eruption of a nearby filament. A method to create a large field-of-view is to join several fields-of-view into a mosaic. Fields are imaged quickly one after another using fast telescope-pointing. Such a pointing cycle has been automated at the Dutch Open Telescope (DOT), a high-resolution solar telescope located on the Canary Island La Palma. The observer can draw with the computer mouse the desired total field in the guider-telescope image of the whole Sun. The guider telescope is equipped with an H-alpha filter and electronic enhancement of contrast in the image for good visibility of filaments and prominences. The number and positions of the subfields are calculated automatically and represented by an array of bright points indicating the subfield centers inside the drawn rectangle of the total field on the computer screen with the whole-sun image. When the exposures start the telescope repeats automatically the sequence of subfields. Automatic production of flats is also programmed including defocusing and fast motion over the solar disk of the image field. For the first time mosaic movies were programmed from stored information on automated telescope motions from one field to the next. The mosaic movies fill the gap between whole-sun images with limited resolution of synoptic telescopes including space instruments and small-field high-cadence movies of high-resolution solar telescopes.
NASA Astrophysics Data System (ADS)
Wheeler, Thomas
2011-10-01
This proposal consists of the steps necessary for turning on and ramping up {in magnitude} the COS FUV high voltage and returning the FUV detector to science operations in a conservative manner after a HV anomalous or burst event {similar to what has been seen on FUSE} shutdown. HSTAR 13305 provides details and timeline of the present shutdown. The complete step-by-step procedure is detailed in the Observing Description, but in summary, the following is done: Groups of sequences with one dayâ??s activities with the QE grid off and one dayâ??s activities with the QE grid on alternate to progressively higher voltages with the QE off group leading by one sequence. The initial HV turn on {Day 1} occurs with the QE grid off; the initial transition from FUV Operate to HVLow is broken into two parts with a 1- hour wait between turning the HV on and ramping to HVLow {SAA}. The next Day 1 visit is 1 hour later, where the HV is turned off by returning the FUV Operate state. After another1-hour wait, the QE grid is turned on, the HV is turned on and the voltage is not ramped. After another 1-hour wait, the HV is turned off returning to FUV Operate. The Day 1 ends with the NSSC-1 COS flag 3 is set to prevent any FUV HV commanding. This is followed by 10 cycles {2 * 5 cycles - one set of cycles with the grid off and one set with the grid on} of HV ramp-ups and returns to FUV Operate {HV off} alternating between grid off and on with the QE off group leading by one HV setting. The HV Commanded Counts for each group of cycles are: 154/151, 160/157, 166/163, 172/169, HVNom {178/175}. {The formula to convert Command Counts to HV is: Volts = {Command Counts * -15.69V} -2500V.}The QE off and QE on cycles are similar except for the QE commanding. One typical QE off cycle is shown below:V14 QE off - Ramp to 166/163After V10 by 2D for analysis. Flag 3 must be cleared to execute. 1. QE off - Turn HV on 2. Ramp to HVLow {100/100} 3. Ramp HV to 166/163 4. DCE RAM dump 5. Dark exposure 6. Wave exposureV15 Return to OperateAfter V14 by 1hr 1. Dark exposure 2. Wave exposure 3. Return to HVLow {100/100} 4. Return to Operate {HV off} 5. DCE RAM Dump 6. Set flag 3In some later cycles with the QE grid on, ground system QasiStates are used to auto-schedule the Operate to HVNom transition. Visits 21 and 25 are going to HVNom {178/175} with the QE grid off and on, respectively. There will be a gap of 2days between grid-off cycles and 2 days between grid-on cycles, offset by 1 day. {See the proposal description for exact timing.}All HV ramp-up will be done at the nominal value of 3 seconds per HV "step" rather than 10 seconds per HV "step" used in SMOV. The concern during SMOV was that gas exposure during launch would allow gas to adsorb on the MCP pore surfaces, and that slower ramping would help to remove this excess gas. This concern no longer exists. The cycle voltage values {for Segments A and B} must be patched in FSW in each cycle prior to the HV ramp commanding. Memory monitors will be set on the patched memory locations. Immediately after obtaining the commanded voltage for that cycle and after return to FUV Operate {HV-off} commanding, the DCE memory will be dumped. After HV ramp-up commanding starting with HVLow and prior to returning to HV off, short DARK exposures {300 secs.} with Stim Rate = 2000 will be obtained and after HV ramp-up commanding starting with levels above HVLow and prior to returning to HV off, short WAVE exposures {60 secs.} will be obtained. After all visits that end with Return to Operate {HV off}, NSSC-1 COS event flag 3 will be set to inhibit any FUV commanding, a.k.a. a â??dead manâ??sâ?? switch. If the flag remains set, subsequent FUV commanding will be skipped. Thus, Operations Requests must be in place to clear the flag prior to those subsequent visits. Real-time monitoring of the telemetry will be used to guide the decisions whether or not to clear the flag. This is also required after the final visit.Throughout the proposal, different â??after byâ?? times, sequence containers, and new alignments are used to optimize flow, schedulability, telemetry and science data analyses, and the clearing of flag 3. The proposal is designed such that the visits and exposures MUST be executed in order.Additionally, all visits are compliant with CARD 3.4.12.8 - COS FUV Mandatory Dwell Time at HVLow {1 hour dwell at HVLow before ramping to a more negative voltage} and CARD 3.4.12.9 â?? COS FUV High Voltage QE Grid Operation {HV must be less negative or equal to the HVLow to switch grid on or off}.
Computer-automated silica aerosol generator and animal inhalation exposure system
McKinney, Walter; Chen, Bean; Schwegler-Berry, Diane; Frazer, Dave G.
2015-01-01
Inhalation exposure systems are necessary tools for determining the dose response relationship of inhaled toxicants under a variety of exposure conditions. The objective of this study was to develop an automated computer controlled system to expose small laboratory animals to precise concentrations of uniformly dispersed airborne silica particles. An acoustical aerosol generator was developed which was capable of re-suspending particles from bulk powder. The aerosolized silica output from the generator was introduced into the throat of a venturi tube. The turbulent high-velocity air stream within the venturi tube increased the dispersion of the re-suspended powder. That aerosol was then used to expose small laboratory animals to constant aerosol concentrations, up to 20mg/m3, for durations lasting up to 8h. Particle distribution and morphology of the silica aerosol delivered to the exposure chamber were characterized to verify that a fully dispersed and respirable aerosol was being produced. The inhalation exposure system utilized a combination of airflow controllers, particle monitors, data acquisition devices and custom software with automatic feedback control to achieve constant and repeatable exposure environments. The automatic control algorithm was capable of maintaining median aerosol concentrations to within ±0.2 mg/m3 of a user selected target concentration during exposures lasting from 2 to 8 h. The system was able to reach 95% of the desired target value in <10min during the beginning phase of an exposure. This exposure system provided a highly automated tool for conducting inhalation toxicology studies involving silica particles. PMID:23796015
ERIC Educational Resources Information Center
Choi, Jaehwa; Kim, HeeKyoung; Pak, Seohong
2018-01-01
The recent interests in research in the assessment field have been rapidly shifting from decision-maker-centered assessments to learner-centered assessments (i.e., diagnostic and/or formative assessments). In particular, it is a very important research topic in this field to analyze how these learner-centered assessments are developed more…
Assessment of Knowledge of Day-Care Center Workers in Basic Aspects of Child Care: A Pilot Study.
1980-06-01
to make a score of at least 70 percent on the multiple choice portion of the questionnaire used in this study . %~u CHAPTER II THE REVIEW OF LITERATURE...employees. These factors would automatically introduce a source of bias into the study . Of the centers contacted, one for-profit center, a franchise center...order to obtain consent. These centers were subsequently exclu- ded from the study leaving only three strata: operated for- profit centers (from her on
Fürbass, F; Ossenblok, P; Hartmann, M; Perko, H; Skupch, A M; Lindinger, G; Elezi, L; Pataraia, E; Colon, A J; Baumgartner, C; Kluge, T
2015-06-01
A method for automatic detection of epileptic seizures in long-term scalp-EEG recordings called EpiScan will be presented. EpiScan is used as alarm device to notify medical staff of epilepsy monitoring units (EMUs) in case of a seizure. A prospective multi-center study was performed in three EMUs including 205 patients. A comparison between EpiScan and the Persyst seizure detector on the prospective data will be presented. In addition, the detection results of EpiScan on retrospective EEG data of 310 patients and the public available CHB-MIT dataset will be shown. A detection sensitivity of 81% was reached for unequivocal electrographic seizures with false alarm rate of only 7 per day. No statistical significant differences in the detection sensitivities could be found between the centers. The comparison to the Persyst seizure detector showed a lower false alarm rate of EpiScan but the difference was not of statistical significance. The automatic seizure detection method EpiScan showed high sensitivity and low false alarm rate in a prospective multi-center study on a large number of patients. The application as seizure alarm device in EMUs becomes feasible and will raise the efficiency of video-EEG monitoring and the safety levels of patients. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Bees Algorithm for Construction of Multiple Test Forms in E-Testing
ERIC Educational Resources Information Center
Songmuang, Pokpong; Ueno, Maomi
2011-01-01
The purpose of this research is to automatically construct multiple equivalent test forms that have equivalent qualities indicated by test information functions based on item response theory. There has been a trade-off in previous studies between the computational costs and the equivalent qualities of test forms. To alleviate this problem, we…
14 CFR 23.812 - Emergency lighting.
Code of Federal Regulations, 2010 CFR
2010-01-01
... light that illuminates in the cockpit when power is on in the airplane and the emergency lighting... station and be provided with automatic activation. The cockpit control device must have “on,” “off,” and... “armed” or “on” positions. (e) The cockpit control device must have provisions to allow the emergency...
/Start technology conserves energy by shutting off the gasoline engine when the vehicle is at rest, such as at a traffic light, and automatically re-starting it when the driver pushes the gas pedal to go engine when pulling out from a stop and generating electricity which is stored in the battery. Main stage
Some Thermophysical Properties of Blood Components and Coolants for Frozen Blood Shipping Containers
1989-09-01
SP number by sending a DP reading. Subroutine : AutoControl Automatic control to set temperature. : Autodisplay Get ilL Thermocouple readings and...RETURN 133 AutoControl : Auto control Mode ON TIMER(ReportTime) GOSUB Autodisplay Update Screen in constant interval TIMER ON WHILE Success a 0 Turn off
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., United States of America Standard 300-pound standard minimum, fitted with suitable soft gasket material... shut-off valves located as close to the tank as possible. (d) Excess flow valves where required by this section shall close automatically at the rated flow of vapor or liquid as specified by the manufacturer...
40 CFR 59.653 - How do I test portable fuel containers?
Code of Federal Regulations, 2011 CFR
2011-07-01
... PRODUCTS Control of Evaporative Emissions From New and In-Use Portable Fuel Containers Certifying Emission... container must be tested in their open condition unless they close automatically and are unlikely to be left open by the user during typical storage. All manual closures such as caps must be left off the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, B; Kanal, K; Dickinson, R
2014-06-15
Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structuredmore » Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.« less
Nonlinear matching measure for the analysis of on-off type DNA microarray images
NASA Astrophysics Data System (ADS)
Kim, Jong D.; Park, Misun; Kim, Jongwon
2003-07-01
In this paper, we propose a new nonlinear matching measure for automatic analysis of the on-off type DNA microarray images in which the hybridized spots are detected by the template matching method. The targeting spots of HPV DNA chips are designed for genotyping the human papilloma virus(HPV). The proposed measure is obtained by binarythresholding over the whole template region and taking the number of white pixels inside the spotted area. This measure is evaluated in terms of the accuracy of the estimated marker location to show better performance than the normalized covariance.
Alternate avionics system study and phase B extension
NASA Technical Reports Server (NTRS)
1971-01-01
Results of alternate avionics system studies for the space shuttle are presented that reduce the cost of vehicle avionics without incurring major off-setting costs on the ground. A comprehensive summary is provided of all configurations defined since the completion of the basic Phase B contract and a complete description of the optimized avionics baseline is given. In the new baseline, inflight redundancy management is performed onboard without ground support; utilization of off-the-shelf hardware reduces the cost figure substantially less than for the Phase B baseline. The only functional capability sacrificed in the new approach is automatic landing.
A Not-So-Fundamental Limitation on Studying Complex Systems with Statistics: Comment on Rabin (2011)
NASA Astrophysics Data System (ADS)
Thomas, Drew M.
2012-12-01
Although living organisms are affected by many interrelated and unidentified variables, this complexity does not automatically impose a fundamental limitation on statistical inference. Nor need one invoke such complexity as an explanation of the "Truth Wears Off" or "decline" effect; similar "decline" effects occur with far simpler systems studied in physics. Selective reporting and publication bias, and scientists' biases in favor of reporting eye-catching results (in general) or conforming to others' results (in physics) better explain this feature of the "Truth Wears Off" effect than Rabin's suggested limitation on statistical inference.
Mesoscopic-microscopic spatial stochastic simulation with automatic system partitioning.
Hellander, Stefan; Hellander, Andreas; Petzold, Linda
2017-12-21
The reaction-diffusion master equation (RDME) is a model that allows for efficient on-lattice simulation of spatially resolved stochastic chemical kinetics. Compared to off-lattice hard-sphere simulations with Brownian dynamics or Green's function reaction dynamics, the RDME can be orders of magnitude faster if the lattice spacing can be chosen coarse enough. However, strongly diffusion-controlled reactions mandate a very fine mesh resolution for acceptable accuracy. It is common that reactions in the same model differ in their degree of diffusion control and therefore require different degrees of mesh resolution. This renders mesoscopic simulation inefficient for systems with multiscale properties. Mesoscopic-microscopic hybrid methods address this problem by resolving the most challenging reactions with a microscale, off-lattice simulation. However, all methods to date require manual partitioning of a system, effectively limiting their usefulness as "black-box" simulation codes. In this paper, we propose a hybrid simulation algorithm with automatic system partitioning based on indirect a priori error estimates. We demonstrate the accuracy and efficiency of the method on models of diffusion-controlled networks in 3D.
Space Shuttle Discovery Launch
2008-05-31
NASA Shuttle Launch Director Michael Leinbach, left, STS-124 Assistant Launch Director Ed Mango, center, and Flow Director for Space Shuttle Discovery Stephanie Stilson clap in the the Launch Control Center after the main engine cut off and successful launch of the Space Shuttle Discovery (STS-124) Saturday, May 31, 2008, at the Kennedy Space Center in Cape Canaveral, Fla. The Shuttle lifted off from launch pad 39A at 5:02 p.m. EDT. Photo Credit: (NASA/Bill Ingalls)
V/STOLAND digital avionics system for XV-15 tilt rotor
NASA Technical Reports Server (NTRS)
Liden, S.
1980-01-01
A digital flight control system for the tilt rotor research aircraft provides sophisticated navigation, guidance, control, display and data acquisition capabilities for performing terminal area navigation, guidance and control research. All functions of the XV-15 V/STOLAND system were demonstrated on the NASA-ARC S-19 simulation facility under a comprehensive dynamic acceptance test. The most noteworthy accomplishments of the system are: (1) automatic configuration control of a tilt-rotor aircraft over the total operating range; (2) total hands-off landing to touchdown on various selectable straight-in glide slopes and on a flight path that includes a two-revolution helix; (3) automatic guidance along a programmed three-dimensional reference flight path; (4) navigation data for the automatic guidance computed on board, based on VOR/DME, TACAN, or MLS navid data; and (5) integration of a large set of functions in a single computer, utilizing 16k words of storage for programs and data.
Trueblood, Amber B; Forrester, Mathias B; Han, Daikwon; Shipp, Eva M; Cizmas, Leslie H
2016-11-01
Although national poison center data show that pesticides were the 8th most commonly reported substance category (3.27%) for children aged ≤5 years in 2014, there is limited information on childhood and adolescent pesticide exposures. This study assessed pesticide-related poison center exposures in children and adolescents aged ≤19 years from 2000-2013 in Texas to characterize the potential burden of pesticides. Pesticide-related poison center exposures among children and adolescents aged ≤19 years reported to Texas poison centers were identified. The distribution of exposures was estimated by gender, age category, medical outcome, management site, exposure route, and pesticide category. From 2000 to 2013, there were 61,147 pesticide-related poison center exposures in children and adolescents aged ≤19 years. The prevalence was highest among males at 864.24 per 100,000 population. The prevalence of unintentional exposures was highest among children aged ≤5 years at 2310.69 per 100,000 population, whereas the prevalence of intentional exposures was highest among adolescents aged 13-19 years at 13.82 per 100,000 population. A majority of medical outcomes reported were classified as having no effect (30.24%) and not followed, but minimal clinical effects possible (42.74%). Of all the exposures, 81.24% were managed on site. However, 57% of intentional exposures were referred to or treated at a health-care facility. The most common routes of exposure were ingestion (80.83%) and dermal (17.21%). The most common pesticide categories included rodenticides (30.02%), pyrethrins/pyrethroids (20.69%), and other and unspecified insecticides (18.14%). The study found differences in the frequency of exposures by intent for sex and age categories, and identified the most common medical outcomes, management site, exposure route, and pesticide category. Through characterizing pesticide-related poison center exposures, future interventions can be designed to address groups with higher prevalence of exposure.
Suwalski, Grzegorz; Emery, Robert; Mróz, Jakub; Kaczejko, Kamil; Gryszko, Leszek; Cwetsch, Andrzej; Skrobowski, Andrzej
2017-06-01
Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Svedberg, Urban; Johanson, Gunnar
2017-03-01
Containerized cargo shipment makes up the backbone of international trade. The principal aim of this cross-sectional study was to establish a qualitative and quantitative description of gaseous fumigants and volatile off-gassing substances facing workers tasked with entering shipping containers. A total of 372 packed and 119 empty shipping containers were sampled in six ports and two distribution centers in Sweden. Fourier-transform infrared spectrometry (FTIR) and photoionization detection (PID) were the analytical methods applied to the bulk of samples. A small number of adsorbent samples were analyzed using gas chromatography-mass spectrometry (GC-MS). The results were compared to Swedish occupational exposure limits (OELs), the closest parallel to relevant work situations. Based on the FTIR analyses, 30 of 249 (12%) containers arrived with concentrations of fumigants and off-gassing substances above the 8-h OELs and close to 7% were above the short-term exposure limits. Eight detected chemicals were classified as carcinogens and 4% of the containers arrived with levels of carcinogens above the OELs, at a maximum 30 times the 8-h OEL. Considerable differences were observed between ports, ranging from 0 to 33% of containers arriving with concentrations above the OELs. It is believed that all observation results, apart from a single instance of a confirmed fumigant, phosphine, at 3 p.p.m., and possibly three instances of carbon dioxide, can be attributed to off-gassing substances. The FTIR methodology proved useful for quick preliminary checks and in-depth screening and identification. The PID method produced both false-negative and false-positive results where only 48% matched the FTIR observations. Adsorbent sampling with GC-MS analysis was useful for confirming volatile organic compounds but was deemed too slow for day-to-day screening. The high frequency of contaminated containers, the detection of several carcinogens, and the sporadic occurrences of high levels of fumigants are serious concerns that need to be properly recognized in order to protect the workers at risk. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
ERIC Educational Resources Information Center
Shih, Ching-Hsiang
2011-01-01
This study combines multi-mice technology (people with disabilities can use standard mice, instead of specialized alternative computer input devices, to achieve complete mouse operation) with an assistive pointing function (i.e. cursor-capturing, which enables the user to move the cursor to the target center automatically), to assess whether two…
[Automatic Sleep Stage Classification Based on an Improved K-means Clustering Algorithm].
Xiao, Shuyuan; Wang, Bei; Zhang, Jian; Zhang, Qunfeng; Zou, Junzhong
2016-10-01
Sleep stage scoring is a hotspot in the field of medicine and neuroscience.Visual inspection of sleep is laborious and the results may be subjective to different clinicians.Automatic sleep stage classification algorithm can be used to reduce the manual workload.However,there are still limitations when it encounters complicated and changeable clinical cases.The purpose of this paper is to develop an automatic sleep staging algorithm based on the characteristics of actual sleep data.In the proposed improved K-means clustering algorithm,points were selected as the initial centers by using a concept of density to avoid the randomness of the original K-means algorithm.Meanwhile,the cluster centers were updated according to the‘Three-Sigma Rule’during the iteration to abate the influence of the outliers.The proposed method was tested and analyzed on the overnight sleep data of the healthy persons and patients with sleep disorders after continuous positive airway pressure(CPAP)treatment.The automatic sleep stage classification results were compared with the visual inspection by qualified clinicians and the averaged accuracy reached 76%.With the analysis of morphological diversity of sleep data,it was proved that the proposed improved K-means algorithm was feasible and valid for clinical practice.
Bending and Torsion Load Alleviator With Automatic Reset
NASA Technical Reports Server (NTRS)
delaFuente, Horacio M. (Inventor); Eubanks, Michael C. (Inventor); Dao, Anthony X. (Inventor)
1996-01-01
A force transmitting load alleviator apparatus and method are provided for rotatably and pivotally driving a member to be protected against overload torsional and bending (moment) forces. The load alleviator includes at least one bias spring to resiliently bias cam followers and cam surfaces together and to maintain them in locked engagement unless a predetermined load is exceeded whereupon a center housing is pivotal or rotational with respect to a crown assembly. This pivotal and rotational movement results in frictional dissipation of the overload force by an energy dissipator. The energy dissipator can be provided to dissipate substantially more energy from the overload force than from the bias force that automatically resets the center housing and crown assembly to the normally fixed centered alignment. The torsional and bending (moment) overload levels can designed independently of each other.
Tolia, Veeral N; Desai, Sujata; Qin, Huanying; Rayburn, Polli D; Poon, Grace; Murthy, Karna; Ellsbury, Dan L; Chiruvolu, Arpitha
2017-01-01
Objective To evaluate if an antibiotic automatic stop order (ASO) changed early antibiotic exposure (use in the first 7 days of life) or clinical outcomes in very low birth weight (VLBW) infants. Study Design We compared birth characteristics, early antibiotic exposure, morbidity, and mortality data in VLBW infants (with birth weight <= 1500 g) born 2 years before (pre-ASO group, n = 313) to infants born in the 2 years after (post-ASO, n = 361) implementation of an ASO guideline. Early antibiotic exposure was quantified by days of therapy (DOT) and antibiotic use > 48 hours. Secondary outcomes included mortality, early mortality, early onset sepsis (EOS), and necrotizing enterocolitis. Results Birth characteristics were similar between the two groups. We observed reduced median antibiotic exposure (pre-ASO: 6.5 DOT vs. Post-ASO: 4 DOT; p < 0.001), and a lower percentage of infants with antibiotic use > 48 hours (63.4 vs. 41.3%; p < 0.001). There were no differences in mortality (12.1 vs 10.2%; p = 0.44), early mortality, or other reported morbidities. EOS accounted for less than 10% of early antibiotic use. Conclusion Early antibiotic exposure was reduced after the implementation of an ASO without changes in observed outcomes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Knaapen, Paul; de Mulder, Maarten; van der Zant, Friso M; Peels, Hans O; Twisk, Jos W R; van Rossum, Albert C; Cornel, Jan H; Umans, Victor A W M
2009-02-01
Primary percutaneous coronary intervention (PCI) performed in large community hospitals without cardiac surgery back-up facilities (off-site) reduces door-to-balloon time compared with emergency transferal to tertiary interventional centers (on-site). The present study was performed to explore whether off-site PCI for acute myocardial infarction results in reduced infarct size. One hundred twenty-eight patients with acute ST-segment elevation myocardial infarction were randomly assigned to undergo primary PCI at the off-site center (n = 68) or to transferal to an on-site center (n = 60). Three days after PCI, (99m)Tc-sestamibi SPECT was performed to estimate infarct size. Off-site PCI significantly reduced door-to-balloon time compared with on-site PCI (94 +/- 54 versus 125 +/- 59 min, respectively, p < 0.01), although symptoms-to-treatment time was only insignificantly reduced (257 +/- 211 versus 286 +/- 146 min, respectively, p = 0.39). Infarct size was comparable between treatment centers (16 +/- 15 versus 14 +/- 12%, respectively p = 0.35). Multivariate analysis revealed that TIMI 0/1 flow grade at initial coronary angiography (OR 3.125, 95% CI 1.17-8.33, p = 0.023), anterior wall localization of the myocardial infarction (OR 3.44, 95% CI 1.38-8.55, p < 0.01), and development of pathological Q-waves (OR 5.07, 95% CI 2.10-12.25, p < 0.01) were independent predictors of an infarct size > 12%. Off-site PCI reduces door-to-balloon time compared with transferal to a remote on-site interventional center but does not reduce infarct size. Instead, pre-PCI TIMI 0/1 flow, anterior wall infarct localization, and development of Q-waves are more important predictors of infarct size.
NASA Astrophysics Data System (ADS)
Cleve, Marianne; Krämer, Martin; Gussew, Alexander; Reichenbach, Jürgen R.
2017-06-01
Phase and frequency corrections of magnetic resonance spectroscopic data are of major importance to obtain reliable and unambiguous metabolite estimates as validated in recent research for single-shot scans with the same spectral fingerprint. However, when using the J-difference editing technique 1H MEGA-PRESS, misalignment between mean edited (ON ‾) and non-edited (OFF ‾) spectra that may remain even after correction of the corresponding individual single-shot scans results in subtraction artefacts compromising reliable GABA quantitation. We present a fully automatic routine that iteratively optimizes simultaneously relative frequencies and phases between the mean ON ‾ and OFF ‾ 1H MEGA-PRESS spectra while minimizing the sum of the magnitude of the difference spectrum (L1 norm). The proposed method was applied to simulated spectra at different SNR levels with deliberately preset frequency and phase errors. Difference optimization proved to be more sensitive to small signal fluctuations, as e.g. arising from subtraction artefacts, and outperformed the alternative spectral registration approach, that, in contrast to our proposed linear approach, uses a nonlinear least squares minimization (L2 norm), at all investigated levels of SNR. Moreover, the proposed method was applied to 47 MEGA-PRESS datasets acquired in vivo at 3 T. The results of the alignment between the mean OFF ‾ and ON ‾ spectra were compared by applying (a) no correction, (b) difference optimization or (c) spectral registration. Since the true frequency and phase errors are not known for in vivo data, manually corrected spectra were used as the gold standard reference (d). Automatically corrected data applying both, method (b) or method (c), showed distinct improvements of spectra quality as revealed by the mean Pearson correlation coefficient between corresponding real part mean DIFF ‾ spectra of Rbd = 0.997 ± 0.003 (method (b) vs. (d)), compared to Rad = 0.764 ± 0.220 (method (a) vs. (d)) with no alignment between OFF ‾ and ON ‾ . Method (c) revealed a slightly lower correlation coefficient of Rcd = 0.972 ± 0.028 compared to Rbd, that can be ascribed to small remaining subtraction artefacts in the final DIFF ‾ spectrum. In conclusion, difference optimization performs robustly with no restrictions regarding the input data range or user intervention and represents a complementary tool to optimize the final DIFF ‾ spectrum following the mandatory frequency and phase corrections of single ON and OFF scans prior to averaging.
Factors determining the exposure of dairy farmers to thoracic organic dust.
Pfister, Hugo; Madec, Laurent; Cann, Pierre Le; Costet, Nathalie; Chouvet, Martine; Jouneau, Stéphane; Vernhet, Laurent
2018-08-01
Bronchial respiratory diseases are more common in dairy farmers than in the general population, perhaps because the repeated inhalation of organic dust contributes to the development of these disorders. However, the factors determining the exposure of farmers to particles that can enter the lower bronchial tract and interact with it, i.e. the thoracic fraction of the inhalable dust, remain to be identified. We therefore measured the exposure of dairy farmers to thoracic organic dust and identified the farm features and tasks that increased exposure. We measured thoracic particles (n = 110) and farm characteristics and occupational tasks in 29 Brittany dairy farms. The mean (GM) (geometric standard deviation, GSD) concentration of thoracic dust in air inhaled by farmers was 0.24 mg/m 3 (2.8) and the concentrations of endotoxins, Gram-positive bacteria and fungi in the thoracic fraction were 128 EU/m 3 (4.0), 960 CFU/m 3 (6.3) and 690 CFU/m 3 (5.4), respectively. Model-based estimates of the association between exposure, farm features and tasks indicated that manual grain and feed handling and mechanical bedding spreading significantly increased exposure to thoracic dust, endotoxins, bacteria and fungi. Exposure to bacteria and fungi was reduced by cowsheds divided into cubicles, whereas using automatic muck scrappers in alleyway and automatic milking tended to increase exposure to bacteria and endotoxins. Finally, exposure to endotoxin and fungi were reduced by warmer farm buildings and well-ventilated buildings having walls with large openings. In conclusions, major occupational tasks and specific farm features determine the exposure of Breton dairy farmers to thoracic organic dust. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Choi, Jang-Hwan; Muller, Kerstin; Hsieh, Scott; Maier, Andreas; Gold, Garry; Levenston, Marc; Fahrig, Rebecca
2016-03-01
C-arm-based cone-beam CT (CBCT) systems with flat-panel detectors are suitable for diagnostic knee imaging due to their potentially flexible selection of CT trajectories and wide volumetric beam coverage. In knee CT imaging, over-exposure artifacts can occur because of limitations in the dynamic range of the flat panel detectors present on most CBCT systems. We developed a straightforward but effective method for correction and detection of over-exposure for an Automatic Exposure Control (AEC)-enabled standard knee scan incorporating a prior low dose scan. The radiation dose associated with the low dose scan was negligible (0.0042mSv, 2.8% increase) which was enabled by partially sampling the projection images considering the geometry of the knees and lowering the dose further to be able to just see the skin-air interface. We combined the line integrals from the AEC and low dose scans after detecting over-exposed regions by comparing the line profiles of the two scans detector row-wise. The combined line integrals were reconstructed into a volumetric image using filtered back projection. We evaluated our method using in vivo human subject knee data. The proposed method effectively corrected and detected over-exposure, and thus recovered the visibility of exterior tissues (e.g., the shape and density of the patella, and the patellar tendon), incorporating a prior low dose scan with a negligible increase in radiation exposure.
The Off-Campus Center: Extending the Reach of Higher Education. Organizational Issues.
ERIC Educational Resources Information Center
Gabor, Stanley C.; Heggan, Jon P.
Based on a study of basic organizational issues typically encountered in opening, managing, and closing an off-campus center (OCC), this monograph is designed for colleges and universities wishing to explore the possibility of creating or expanding an OCC for adult students. The definition of an OCC is provided. After a brief statistical overview…
An Assessment of a New Off-Campus Location.
ERIC Educational Resources Information Center
Cosgrove, John J.
A study was conducted at St. Louis Community College (SLCC) to obtain students' opinions of the Clarkson Education Center (CEC), a new off-campus educational center opened in summer, 1984. The study sought information on the students enrolled at CEC and how they differed from the SLCC student body as a whole; students' views of the quality of…
van Harmelen, Anne-Laura; de Jong, Peter J; Glashouwer, Klaske A; Spinhoven, Philip; Penninx, Brenda W J H; Elzinga, Bernet M
2010-06-01
Individuals reporting Childhood Abuse (CA) (i.e., emotional neglect, emotional-, physical- and sexual-abuse) are marked by increased explicit (i.e. self-reported) negative self-associations, and an increased risk to develop depression or anxiety disorders. Automatic self-associations might play an important role in the development and maintenance of affective disorders after exposure to CA, since automatic associations are assumed to be involved in uncontrolled (spontaneous) affective behavior. This study examined whether individuals reporting a history of CA show stronger automatic (and explicit) self-depression and/or self-anxiety associations than individuals who report no CA in a large cohort study (Netherlands Study of Depression and Anxiety (NESDA), n = 2981). The Implicit Association Test (IAT) was utilized to assess automatic self-depression and self-anxiety associations. We found that CA was associated with enhanced automatic (and explicit) self-depression and self-anxiety associations. Additionally, when compared to physical- and sexual-abuse, Childhood Emotional Maltreatment (CEM; emotional abuse and emotional neglect) had the strongest link with enhanced automatic (and explicit) self-depression and self-anxiety associations. In addition, automatic and explicit negative self-associations partially mediated the association between CEM and depressive or anxious symptomatology. Implications regarding the importance of CA, and CEM in particular will be discussed. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Wide acceptance angle, high concentration ratio, optical collector
NASA Technical Reports Server (NTRS)
Kruer, Mark Arthur (Inventor)
1990-01-01
The invention is directed to an optical collector requiring a wide acceptance angle, and a high concentration ratio. The invention is particularly adapted for use in solar collectors of cassegrain design. The optical collector system includes a parabolic circular concave primary mirror and a hyperbolic circular convex secondary mirror. The primary mirror includes a circular hole located at its center wherein a solar collector is located. The mirrored surface of the secondary mirror has three distinct zones: a center circle, an on-axis annulus, and an off-axis section. The parabolic shape of the primary mirror is chosen so that the primary mirror reflects light entering the system on-axis onto the on-axis annulus. A substantial amount of light entering the system off-axis is reflected by the primary mirror onto either the off-axis section or onto the center circle. Subsequently, the off-axis sections reflect the off-axis light toward the solar collector. Thus, off-axis light is captured which would otherwise be lost to the system. The novelty of the system appears to lie in the configuration of the primary mirror which focuses off-axis light onto an annular portion of the secondary mirror to enable capture thereof. This feature results in wide acceptance angle and a high concentration ratio, and also compensates for the effects of non-specular reflection, and enables a cassegrain configuration to be used where such characteristics are required.
NASA Scientific Data Purchase Project: From Collection to User
NASA Technical Reports Server (NTRS)
Nicholson, Lamar; Policelli, Fritz; Fletcher, Rose
2002-01-01
NASA's Scientific Data Purchase (SDP) project is currently a $70 million operation managed by the Earth Science Applications Directorate at Stennis Space Center. The SDP project was developed in 1997 to purchase scientific data from commercial sources for distribution to NASA Earth science researchers. Our current data holdings include 8TB of remote sensing imagery consisting of 18 products from 4 companies. Our anticipated data volume is 60 TB by 2004, and we will be receiving new data products from several additional companies. Our current system capacity is 24 TB, expandable to 89 TB. Operations include tasking of new data collections, archive ordering, shipment verification, data validation, distribution, metrics, finances, customer feedback, and technical support. The program has been included in the Stennis Space Center Commercial Remote Sensing ISO 9001 registration since its inception. Our operational system includes automatic quality control checks on data received (with MatLab analysis); internally developed, custom Web-based interfaces that tie into commercial-off-the-shelf software; and an integrated relational database that links and tracks all data through operations. We've distributed nearly 1500 datasets, and almost 18,000 data files have been downloaded from our public web site; on a 10-point scale, our customer satisfaction index is 8.32 at a 23% response level. More information about the SDP is available on our Web site.
Söderberg, Marcus
2016-06-01
Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
FPGA Based Adaptive Rate and Manifold Pattern Projection for Structured Light 3D Camera System †
Lee, Sukhan
2018-01-01
The quality of the captured point cloud and the scanning speed of a structured light 3D camera system depend upon their capability of handling the object surface of a large reflectance variation in the trade-off of the required number of patterns to be projected. In this paper, we propose and implement a flexible embedded framework that is capable of triggering the camera single or multiple times for capturing single or multiple projections within a single camera exposure setting. This allows the 3D camera system to synchronize the camera and projector even for miss-matched frame rates such that the system is capable of projecting different types of patterns for different scan speed applications. This makes the system capturing a high quality of 3D point cloud even for the surface of a large reflectance variation while achieving a high scan speed. The proposed framework is implemented on the Field Programmable Gate Array (FPGA), where the camera trigger is adaptively generated in such a way that the position and the number of triggers are automatically determined according to camera exposure settings. In other words, the projection frequency is adaptive to different scanning applications without altering the architecture. In addition, the proposed framework is unique as it does not require any external memory for storage because pattern pixels are generated in real-time, which minimizes the complexity and size of the application-specific integrated circuit (ASIC) design and implementation. PMID:29642506
1976-04-15
System, Dual-System, Single-Mode, and Dual-Mode configurations. Tests were conducted to determine the feasibility of incorporating modular hardware on a...and 11-1/2 feet OFF-CENTER with the BAK-12 configured in the Single and Dual Mode to determine the effect of engaging the aircraft arresting-hook...cable OFF-CENTER. 90,000- pound deadload arrestments were conducted ON-CENTER in the Dual Mode to determine system performance with high-energy
Work inside ocean freight containers--personal exposure to off-gassing chemicals.
Svedberg, Urban; Johanson, Gunnar
2013-11-01
More than 500 million ocean freight container units are shipped annually between countries and continents. Residual levels of fumigants, as well as naturally occurring off-gassing chemicals emanating from the goods, constitute safety risks, which may affect uniformed workers upon entering the container. The aim of this study was to assess workers' exposure during stripping of containers and is the first study of its kind. First, an experimental tracer gas method was investigated to determine its usefulness to approximate real exposures from gaseous fumigants and off-gassing volatile organic compounds (VOCs). Nitrous oxide was injected and left to distribute in the closed containers. The distribution of the tracer gas and initial (arrival) concentrations of off-gassing volatiles were measured prior to opening the containers. Second, personal exposure (breathing zone) and work zone air monitoring of both tracer gas and VOCs were carried out during stripping. Adsorbent tubes, bag samples, and direct-readings instruments (photoionization detector and Fourier transform infrared spectrometry) were used. The distribution studies with nitrous oxide, and the high correlation between the former and VOCs (r(2) ~ 0.8) during stripping, showed that the tracer gas method may well be used to approximate real exposures in containers. The average breathing zone and work zone concentrations during stripping of naturally ventilated 40-foot containers were 1-7% of the arrival concentrations; however, peaks up to 70% were seen during opening. Even if average exposures during stripping are significantly lower than arrival concentrations, they may still represent serious violations of occupational exposure limits in high-risk containers. The results from this and previous studies illustrate the need to establish practices for the safe handling of ocean freight containers. Until comprehensive recommendations are in place, personnel that need to enter such containers should, in addition to appropriate personal protective equipment, have access to equipment for measuring contaminants and for applying forced ventilation when necessary.
Work Inside Ocean Freight Containers—Personal Exposure to Off-Gassing Chemicals
Svedberg, Urban
2013-01-01
More than 500 million ocean freight container units are shipped annually between countries and continents. Residual levels of fumigants, as well as naturally occurring off-gassing chemicals emanating from the goods, constitute safety risks, which may affect uniformed workers upon entering the container. The aim of this study was to assess workers’ exposure during stripping of containers and is the first study of its kind. First, an experimental tracer gas method was investigated to determine its usefulness to approximate real exposures from gaseous fumigants and off-gassing volatile organic compounds (VOCs). Nitrous oxide was injected and left to distribute in the closed containers. The distribution of the tracer gas and initial (arrival) concentrations of off-gassing volatiles were measured prior to opening the containers. Second, personal exposure (breathing zone) and work zone air monitoring of both tracer gas and VOCs were carried out during stripping. Adsorbent tubes, bag samples, and direct-readings instruments (photoionization detector and Fourier transform infrared spectrometry) were used. The distribution studies with nitrous oxide, and the high correlation between the former and VOCs (r 2 ~ 0.8) during stripping, showed that the tracer gas method may well be used to approximate real exposures in containers. The average breathing zone and work zone concentrations during stripping of naturally ventilated 40-foot containers were 1–7% of the arrival concentrations; however, peaks up to 70% were seen during opening. Even if average exposures during stripping are significantly lower than arrival concentrations, they may still represent serious violations of occupational exposure limits in high-risk containers. The results from this and previous studies illustrate the need to establish practices for the safe handling of ocean freight containers. Until comprehensive recommendations are in place, personnel that need to enter such containers should, in addition to appropriate personal protective equipment, have access to equipment for measuring contaminants and for applying forced ventilation when necessary. PMID:23825354
NASA Astrophysics Data System (ADS)
Zheng, Yu; Dong, Lei; Gao, Yang; Dou, Jun-Rong; Li, Ze-yan
2016-10-01
Combined with the use of patch-clamp techniques, repetitive transcranial magnetic stimulation (rTMS) has proven to be a noninvasive neuromodulation tool that can inhibit or facilitate excitability of neurons after extensive research. The studies generally focused on the method: the neurons are first stimulated in an external standard magnetic exposure device, and then moved to the patch-clamp to record electrophysiological characteristics (off-line magnetic exposure). Despite its universality, real-time observation of the effects of magnetic stimulation on the neurons is more effective (on-line magnetic stimulation). In this study, we selected a standard exposure device for magnetic fields acting on mouse prefrontal cortex pyramidal neurons, and described a new method that a patch-clamp setup was modified to allow on-line magnetic stimulation. By comparing the off-line exposure and on-line stimulation of the same magnetic field intensity and frequency affecting the voltage-gated sodium channel currents, we succeeded in proving the feasibility of the new on-line stimulation device. We also demonstrated that the sodium channel currents of prefrontal cortex pyramidal neurons increased significantly under the 15 Hz sine 1 mT, and 2 mT off-line magnetic field exposure and under the 1 mT and 2 mT on-line magnetic stimulation, and the rate of acceleration was most significant on 2 mT on-line magnetic stimulation. This study described the development of a new on-line magnetic stimulator and successfully demonstrated its practicability for scientific stimulation of neurons.
Malcolm, Philippe; Quesada, Roberto E; Caputo, Joshua M; Collins, Steven H
2015-02-22
Robotic ankle-foot prostheses that provide net positive push-off work can reduce the metabolic rate of walking for individuals with amputation, but benefits might be sensitive to push-off timing. Simple walking models suggest that preemptive push-off reduces center-of-mass work, possibly reducing metabolic rate. Studies with bilateral exoskeletons have found that push-off beginning before leading leg contact minimizes metabolic rate, but timing was not varied independently from push-off work, and the effects of push-off timing on biomechanics were not measured. Most lower-limb amputations are unilateral, which could also affect optimal timing. The goal of this study was to vary the timing of positive prosthesis push-off work in isolation and measure the effects on energetics, mechanics and muscle activity. We tested 10 able-bodied participants walking on a treadmill at 1.25 m · s(-1). Participants wore a tethered ankle-foot prosthesis emulator on one leg using a rigid boot adapter. We programmed the prosthesis to apply torque bursts that began between 46% and 56% of stride in different conditions. We iteratively adjusted torque magnitude to maintain constant net positive push-off work. When push-off began at or after leading leg contact, metabolic rate was about 10% lower than in a condition with Spring-like prosthesis behavior. When push-off began before leading leg contact, metabolic rate was not different from the Spring-like condition. Early push-off led to increased prosthesis-side vastus medialis and biceps femoris activity during push-off and increased variability in step length and prosthesis loading during push-off. Prosthesis push-off timing had no influence on intact-side leg center-of-mass collision work. Prosthesis push-off timing, isolated from push-off work, strongly affected metabolic rate, with optimal timing at or after intact-side heel contact. Increased thigh muscle activation and increased human variability appear to have caused the lack of reduction in metabolic rate when push-off was provided too early. Optimal timing with respect to opposite heel contact was not different from normal walking, but the trends in metabolic rate and center-of-mass mechanics were not consistent with simple model predictions. Optimal push-off timing should also be characterized for individuals with amputation, since meaningful benefits might be realized with improved timing.
A study of lateral fall-off (penumbra) optimisation for pencil beam scanning (PBS) proton therapy
NASA Astrophysics Data System (ADS)
Winterhalter, C.; Lomax, A.; Oxley, D.; Weber, D. C.; Safai, S.
2018-01-01
The lateral fall-off is crucial for sparing organs at risk in proton therapy. It is therefore of high importance to minimize the penumbra for pencil beam scanning (PBS). Three optimisation approaches are investigated: edge-collimated uniformly weighted spots (collimation), pencil beam optimisation of uncollimated pencil beams (edge-enhancement) and the optimisation of edge collimated pencil beams (collimated edge-enhancement). To deliver energies below 70 MeV, these strategies are evaluated in combination with the following pre-absorber methods: field specific fixed thickness pre-absorption (fixed), range specific, fixed thickness pre-absorption (automatic) and range specific, variable thickness pre-absorption (variable). All techniques are evaluated by Monte Carlo simulated square fields in a water tank. For a typical air gap of 10 cm, without pre-absorber collimation reduces the penumbra only for water equivalent ranges between 4-11 cm by up to 2.2 mm. The sharpest lateral fall-off is achieved through collimated edge-enhancement, which lowers the penumbra down to 2.8 mm. When using a pre-absorber, the sharpest fall-offs are obtained when combining collimated edge-enhancement with a variable pre-absorber. For edge-enhancement and large air gaps, it is crucial to minimize the amount of material in the beam. For small air gaps however, the superior phase space of higher energetic beams can be employed when more material is used. In conclusion, collimated edge-enhancement combined with the variable pre-absorber is the recommended setting to minimize the lateral penumbra for PBS. Without collimator, it would be favourable to use a variable pre-absorber for large air gaps and an automatic pre-absorber for small air gaps.
The Breakthrough Listen Search for Intelligent Life: Data Calibration using Pulsars
NASA Astrophysics Data System (ADS)
Brinkman-Traverse, Casey Lynn; Gajjar, Vishal; BSRC
2018-01-01
The ability to distinguish ET signals requires a deep understanding of the radio telescopes with which we search; therefore, before we observe stars of interest, the Breathrough Listen scientists at Berkeley SETI Research Center first observe a Pulsar with well-documented flux and polarization properties. The process of calibrating the flux and polarization is a lengthy process by hand, so we produced a pipeline code that will automatically calibrate the pulsar in under an hour. Using PSRCHIVE the code coherently dedisperses the pulsed radio signals, and then calibrates the flux using observation files with a noise diode turning on and off. The code was developed using PSR B1937+ 21 and is primarily used on PSR B0329+54. This will expedite the process of assessing the quality of data collected from the Green Bank Telescope in West Virginia and will allow us to more efficiently find life beyond Planet Earth. Additionally, the stability of the B0329+54 calibration data will allow us to analyze data taken on FRB's with confidence of its cosmic origin.
Lead Exposure in Military Outdoor Firing Ranges.
Greenberg, Nili; Frimer, Ron; Meyer, Robert; Derazne, Estella; Chodick, Gabrial
2016-09-01
Several studies have reported significant airborne lead exposures during training at indoor firing ranges. Scarce attention has been given to airborne lead exposures in outdoor shooting ranges with automatic weapons. To assess the prevalence and magnitude of airborne and blood lead levels (BLL) among firing instructors and shooters in military outdoor ranges. Exposure assessment, for both trainees and instructors, included airborne and BLL during basic and advanced training at outdoor firing ranges. Personal airborne samples were collected in both day and night shooting during both training periods. During basic training, there is 95% likelihood that up to 25% of instructors and 99% likelihood that up to 5% of trainees might be exposed above the action level (AL) (25 μg/m(3)). During advanced training, there is 90% likelihood that 10% of instructors and 99% likelihood that up to 10% of trainees might be exposed above the AL. Military personnel participating in automatic weapon marksmanship training can be exposed to considerable levels of airborne lead during outdoor firing range training. As a result, the Israel Defense Force Medical Corp has classified firing range instructors as workers that require periodic medical examinations. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Automatic Blood Pressure Measurements During Exercise
NASA Technical Reports Server (NTRS)
Weaver, Charles S.
1985-01-01
Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.
Tranquart, F; Mercier, L; Frinking, P; Gaud, E; Arditi, M
2012-07-01
With contrast-enhanced ultrasound (CEUS) now established as a valuable imaging modality for many applications, a more specific demand has recently emerged for quantifying perfusion and using measured parameters as objective indicators for various disease states. However, CEUS perfusion quantification remains challenging and is not well integrated in daily clinical practice. The development of VueBox™ alleviates existing limitations and enables quantification in a standardized way. VueBox™ operates as an off-line software application, after dynamic contrast-enhanced ultrasound (DCE-US) is performed. It enables linearization of DICOM clips, assessment of perfusion using patented curve-fitting models, and generation of parametric images by synthesizing perfusion information at the pixel level using color coding. VueBox™ is compatible with most of the available ultrasound platforms (nonlinear contrast-enabled), has the ability to process both bolus and disruption-replenishment kinetics loops, allows analysis results and their context to be saved, and generates analysis reports automatically. Specific features have been added to VueBox™, such as fully automatic in-plane motion compensation and an easy-to-use clip editor. Processing time has been reduced as a result of parallel programming optimized for multi-core processors. A long list of perfusion parameters is available for each of the two administration modes to address all possible demands currently reported in the literature for diagnosis or treatment monitoring. In conclusion, VueBox™ is a valid and robust quantification tool to be used for standardizing perfusion quantification and to improve the reproducibility of results across centers. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Yokoyama, Y.; Yamane, M.; Miyairi, Y.; Suga, H.; Dunbar, R. B.; Ohkouchi, N.
2017-12-01
Timing of past ice sheet retreat of Antarctic continent has been debated with regards to the global sea level changes since the Last Glacial Maximum (LGM) centered at around 20 ka. Exposure dating using cosmogenic radio nuclide (CRN) for glacial deposits have been widely used to reconstruct the last deglacial history though this cannot apply where no-ice free coasts are existed. One such location is the Wilkes Land where the East Antarctic Ice Sheet (EAIS) is situated directory on seafloor. Sediment cores obtained off the Wilkes Land coast successfully retrieved cores during the Intergrated Ocean Drilling Program (IODP) Expedition 318 (Escuita et al., 2011). Major obstacle to obtain reliable chronology for marine cores around Antarctica is sparsity of carbonate materials such as foraminifera. Thus compound-specific radiocarbon analysis (CSRA) has been used and we applied CSRA to the sediments obtained off the Wilkes land coast. The CSRA targeted C16 and C16:1 fatty acid due to their high degradation rate. Hence low concentrations of these compounds are expected. We found major sedimentation occurred since the beginning of Holocene. The result is then compared to the previously reported dates from the land based CRN dates (eg., Mckintosh et al., 2013; Yamane et al., 2011) to discuss the timing of retreat of EAIS.
78 FR 57250 - Federal Credit Union Ownership of Fixed Assets
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-18
..., branch office, suboffice, service center, parking lot, facility, real estate where an FCU transacts or... waiver request and suggested that the automatic approval provision in the current rule should be... office, suboffice, service center, parking lot, other facility, or real estate where the federal credit...
NASA Astrophysics Data System (ADS)
Berukoff, Steven; Reardon, Kevin; Hays, Tony; Spiess, DJ; Watson, Fraser
2015-08-01
When construction is complete in 2019, the Daniel K. Inouye Solar Telescope will be the most-capable large aperture, high-resolution, multi-instrument solar physics facility in the world. The telescope is designed as a four-meter off-axis Gregorian, with a rotating Coude laboratory designed to simultaneously house and support five first-light imaging and spectropolarimetric instruments. At current design, the facility and its instruments will generate data volumes of 5 PB, produce 108 images, and 107-109 metadata elements annually. This data will not only forge new understanding of solar phenomena at high resolution, but enhance participation in solar physics and further grow a small but vibrant international community.The DKIST Data Center is being designed to store, curate, and process this flood of information, while augmenting its value by providing association of science data and metadata to its acquisition and processing provenance. In early Operations, the Data Center will produce, by autonomous, semi-automatic, and manual means, quality-controlled and -assured calibrated data sets, closely linked to facility and instrument performance during the Operations lifecycle. These data sets will be made available to the community openly and freely, and software and algorithms made available through community repositories like Github for further collaboration and improvement.We discuss the current design and approach of the DKIST Data Center, describing the development cycle, early technology analysis and prototyping, and the roadmap ahead. In this budget-conscious era, a key design criterion is elasticity, the ability of the built system to adapt to changing work volumes, types, and the shifting scientific landscape, without undue cost or operational impact. We discuss our deep iterative development approach, the underappreciated challenges of calibrating ground-based solar data, the crucial integration of the Data Center within the larger Operations lifecycle, and how software and hardware support, intelligently deployed, will enable high-caliber solar physics research and community growth for the DKIST's 40-year lifespan.
ACE Design Study and Experiments
1976-06-01
orthophoto on off-line printer o Automatically compute contours on UNIVAC 1108 and plot on CALCOMP o Manually trace planimetry and drainage from... orthophoto * o Manually edit and trace plotted contours to obtain completed contour manuscript* - Edit errors - Add missing contour detail - Combine...stereomodels - Contours adjusted to drainage chart and spot elevations - Referring to orthophoto , rectified photos, original photos o Normal
Technical Reliability Studies. EOS/ESD Technology Abstracts
1981-01-01
MECHANISMS MELAMINE MESFETS MICROWAVE MIS 15025 AUTOMATIC MACHINE PRECAUTIONS FOR HOS/OiOS 15006 INSTRUCTIONS FOR INSTALLATION AND...ELIMINATION OF EOS INDUCED SECONDARY FAILURE MECHANISMS 15000 USE OF MELAMINE WORK-SURFACE FOR ESD POTENTIAL BLEED OFF 16141 MICROWAVE NANOSECOND... microwave devices, optoelectronics, and selected nonelectronic parts employed in military, space and commercial applications. In addition, a System
ERIC Educational Resources Information Center
Main, Susan; O'Rourke, John
2011-01-01
This paper reports on a pilot study that compared the use of commercial off-the-shelf (COTS) handheld game consoles (HGCs) with traditional teaching methods to develop the automaticity of mathematical calculations and self-concept towards mathematics for year 4 students in two metropolitan schools. One class conducted daily sessions using the HGCs…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-11
..., business telephone number, e-mail address, port of landing, operation type (for catcher/processors.../processor, the at-sea operation type is pre-filled automatically. (3) If an SFP and crab delivery is... Registered Crab Receiver record in eLandings the region in which the stationary floating processor is located...
16 CFR 1212.3 - Requirements for multi-purpose lighters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... reset when or before the user lets go of the lighter. (5) The child-resistant mechanism of a multi... operation can occur; (ii) Have a manual mechanism for turning off the flame when the hands-free function is used; and either (iii) Automatically reset when or before the user lets go of the lighter when the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... section 1404(b) of the Act (``Drain Cover Standard''). In addition to the anti-entrapment devices or... system; gravity drainage system; automatic pump shut-off system or drain disablement. The Pool and Spa... the drain covers, anti-entrapment device/systems, sump or equalizer lines at the site; and report on...
Trunk, Attila; Stefanics, Gábor; Zentai, Norbert; Kovács-Bálint, Zsófia; Thuróczy, György; Hernádi, István
2013-01-01
Potential effects of a 30 min exposure to third generation (3G) Universal Mobile Telecommunications System (UMTS) mobile phone-like electromagnetic fields (EMFs) were investigated on human brain electrical activity in two experiments. In the first experiment, spontaneous electroencephalography (sEEG) was analyzed (n = 17); in the second experiment, auditory event-related potentials (ERPs) and automatic deviance detection processes reflected by mismatch negativity (MMN) were investigated in a passive oddball paradigm (n = 26). Both sEEG and ERP experiments followed a double-blind protocol where subjects were exposed to either genuine or sham irradiation in two separate sessions. In both experiments, electroencephalograms (EEG) were recorded at midline electrode sites before and after exposure while subjects were watching a silent documentary. Spectral power of sEEG data was analyzed in the delta, theta, alpha, and beta frequency bands. In the ERP experiment, subjects were presented with a random series of standard (90%) and frequency-deviant (10%) tones in a passive binaural oddball paradigm. The amplitude and latency of the P50, N100, P200, MMN, and P3a components were analyzed. We found no measurable effects of a 30 min 3G mobile phone irradiation on the EEG spectral power in any frequency band studied. Also, we found no significant effects of EMF irradiation on the amplitude and latency of any of the ERP components. In summary, the present results do not support the notion that a 30 min unilateral 3G EMF exposure interferes with human sEEG activity, auditory evoked potentials or automatic deviance detection indexed by MMN. Copyright © 2012 Wiley Periodicals, Inc.
76 FR 3636 - Ocean Transportation Intermediary License Applicants
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-20
..., Vice President, Application Type: New NVO & OFF License. CDS Global Logistics, Inc. (NVO & OFF), 1001... & Logistics LLC (NVO & OFF), Hoboken Business Center, 50 Harrison Street, Suite 204B, Hoboken, NJ 07030, Officers: Michelle L. Hasenauer, Manager (Qualifying Individual), Harbans S. Shrinkant, Manager...
Engineering studies related to Skylab program. [assessment of automatic gain control data
NASA Technical Reports Server (NTRS)
Hayne, G. S.
1973-01-01
The relationship between the S-193 Automatic Gain Control data and the magnitude of received signal power was studied in order to characterize performance parameters for Skylab equipment. The r-factor was used for the assessment and is defined to be less than unity, and a function of off-nadir angle, ocean surface roughness, and receiver signal to noise ratio. A digital computer simulation was also used to assess to additive receiver, or white noise. The system model for the digital simulation is described, along with intermediate frequency and video impulse response functions used, details of the input waveforms, and results to date. Specific discussion of the digital computer programs used is also provided.
Development report: Automatic System Test and Calibration (ASTAC) equipment
NASA Technical Reports Server (NTRS)
Thoren, R. J.
1981-01-01
A microcomputer based automatic test system was developed for the daily performance monitoring of wind energy system time domain (WEST) analyzer. The test system consists of a microprocessor based controller and hybrid interface unit which are used for inputing prescribed test signals into all WEST subsystems and for monitoring WEST responses to these signals. Performance is compared to theoretically correct performance levels calculated off line on a large general purpose digital computer. Results are displayed on a cathode ray tube or are available from a line printer. Excessive drift and/or lack of repeatability of the high speed analog sections within WEST is easily detected and the malfunctioning hardware identified using this system.
NASA Astrophysics Data System (ADS)
Gaddam, Vamsidhar Reddy; Griwodz, Carsten; Halvorsen, Pâl.
2014-02-01
One of the most common ways of capturing wide eld-of-view scenes is by recording panoramic videos. Using an array of cameras with limited overlapping in the corresponding images, one can generate good panorama images. Using the panorama, several immersive display options can be explored. There is a two fold synchronization problem associated to such a system. One is the temporal synchronization, but this challenge can easily be handled by using a common triggering solution to control the shutters of the cameras. The other synchronization challenge is the automatic exposure synchronization which does not have a straight forward solution, especially in a wide area scenario where the light conditions are uncontrolled like in the case of an open, outdoor football stadium. In this paper, we present the challenges and approaches for creating a completely automatic real-time panoramic capture system with a particular focus on the camera settings. One of the main challenges in building such a system is that there is not one common area of the pitch that is visible to all the cameras that can be used for metering the light in order to nd appropriate camera parameters. One approach we tested is to use the green color of the eld grass. Such an approach provided us with acceptable results only in limited light conditions.A second approach was devised where the overlapping areas between adjacent cameras are exploited, thus creating pairs of perfectly matched video streams. However, there still existed some disparity between di erent pairs. We nally developed an approach where the time between two temporal frames is exploited to communicate the exposures among the cameras where we achieve a perfectly synchronized array. An analysis of the system and some experimental results are presented in this paper. In summary, a pilot-camera approach running in auto-exposure mode and then distributing the used exposure values to the other cameras seems to give best visual results.
Review of LOGEX. Main Report and Appendixes A-I
1975-05-23
been developed on an RCA Spectra 70 machine located at the Army Logistics Management Center, Fort Lee, Virginia. This was undoubtedly an outstanding...Control Number ADP - Automatic Data Processing ACT - Active Duty for Training ALMC - US Army Logistics Management Center AMO - Ammunition AR - Amy...Directorate CPT McClellan, LOGEX Directorate CPT Weaver, LOGEX Directorate United States Army Logistics Management Center Mr. Loper Mr. Ross United States
Filmless Radiographic System for Field Use.
1988-02-12
electronic circuits. The receptor assembly contains the x-ray grid , cassette holder or EPID panel and the sensor panel for the automatic exposure control... Grid lines were still resolved. The appearance of fine details was altered but most of the diagnostic value was retained. The choice of the screens must...A 6:1, 60 lines per inch grid is mounted to the frame on the x-ray entrance side. II.F.4. Ion Chamber The ion chamber is used by the automatic
Method for the fabrication of three-dimensional microstructures by deep X-ray lithography
Sweatt, William C.; Christenson, Todd R.
2005-04-05
A method for the fabrication of three-dimensional microstructures by deep X-ray lithography (DXRL) comprises a masking process that uses a patterned mask with inclined mask holes and off-normal exposures with a DXRL beam aligned with the inclined mask holes. Microstructural features that are oriented in different directions can be obtained by using multiple off-normal exposures through additional mask holes having different orientations. Various methods can be used to block the non-aligned mask holes from the beam when using multiple exposures. A method for fabricating a precision 3D X-ray mask comprises forming an intermediate mask and a master mask on a common support membrane.
Automatic Estimation of Verified Floating-Point Round-Off Errors via Static Analysis
NASA Technical Reports Server (NTRS)
Moscato, Mariano; Titolo, Laura; Dutle, Aaron; Munoz, Cesar A.
2017-01-01
This paper introduces a static analysis technique for computing formally verified round-off error bounds of floating-point functional expressions. The technique is based on a denotational semantics that computes a symbolic estimation of floating-point round-o errors along with a proof certificate that ensures its correctness. The symbolic estimation can be evaluated on concrete inputs using rigorous enclosure methods to produce formally verified numerical error bounds. The proposed technique is implemented in the prototype research tool PRECiSA (Program Round-o Error Certifier via Static Analysis) and used in the verification of floating-point programs of interest to NASA.
77 FR 75162 - Ocean Transportation Intermediary License Applicants
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-19
... Cargo & Logistics, Inc. (NVO), 15606 S. Broadway Center Street, Gardner, CA 90248. Officer: Richard Y..., President (QI). Application Type: Add Trade Name Acco Terramar. DI Global Logistics, Inc. (NVO & OFF), 1730... Arenas, President. Application Type: New NVO & OFF License. Exclusive Global Logistics, Inc. (NVO & OFF...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The U.S. Department of Energy Weldon Spring Site Remedial Action Project (chemical plant site), is a former uranium processing facility located in eastern Missouri on the property of the former U.S. Army Weldon Spring Ordnance Works. Surface water, soil, sludge, sediment, and groundwater within the chemical plant site contain chemical and radioactive contaminants. The Agency for Toxic Substances and Disease Registry (ATSDR) reviewed on-site chemical exposure information and site conditions. ATSDR also prepared several Health Consultations on chemical and radioactive contaminants in areas on and off the DOE chemical plant site. ATSDR also reviewed on-site and off-site radiological exposure informationmore » and conditions. The exposure scenarios ATSDR evaluated include: trespassers swimming in quarry or raffinate pits; reservists performing field activities in the training area; anglers fishing, hunters haunting, and hikers hiking in the conservation areas; residents drinking from off-site private wells; staff and students attending the Francis Howell High School; and consumers of crops (e.g., corn) grown in conservation areas.« less
NASA Technical Reports Server (NTRS)
Calle, Luz Marina; Hintze, Paul E.; Parlier, Christopher R.; Curran, Jerome P.; Kolody, Mark; Perusich, Stephen; Whitten, Mary C.; Trejo, David; Zidek, Jason; Sampson, Jeffrey W.;
2009-01-01
Ceramics can be defmed as a material consisting of hard brittle properties produced from inorganic and nonmetallic minerals made by firing at high temperatures. These materials are compounds between metallic and nonmetallic elements and are either totally ionic, or predominately ionic but having some covalent character. This definition allows for a large range of materials, not all applicable to refractory applications. As this report is focused on potential ceramic materials for high temperature, aggressive exposure applications, the ceramics reviewed as part of this report will focus on refractory ceramics specifically designed and used for these applications. Ceramic materials consist of a wide variety of products. Callister (2000) 1 characterized ceramic materials into six classifications: glasses, clay products, refractories, cements, abrasives, and advanced ceramics. Figure 1 shows this classification system. This review will focus mainly on refractory ceramics and cements as in general, the other classifications are neither applicable nor economical for use in large structures such as the flame trench. Although much work has been done in advanced ceramics over the past decade or so, these materials are likely cost prohibitive and would have to be fabricated off-site, transported to the NASA facilities, and installed, which make these even less feasible. Although the authors reviewed the literature on advanced ceramic refractories 2 center dot 3 center dot 4 center dot 5 center dot 6 center dot 7 center dot 8 center dot 9 center dot 10 center dot 11 center dot 12 after the review it was concluded that these materials should not be ' the focus of this report. A review is in progress on materials and systems for prefabricated refractory ceramic panels, but this review is focusing more on typical refractory materials for prefabricated systems, which could make the system more economically feasible. Refractory ceramics are used for a wide variety of applications. Figure 2 shows many ofthese applications, their life expectancy or requirement, and the exposure temperature for the refractory ceramic. Note that the exposure temperatures for refractory ceramics are very similar to the exposure conditions for specialty ceramics (rocket nozzles, space vehicle re-entry fields, etc.) and yet the life expectancy or requirement is relatively low. Currently NASA is repairing the refractory lining in the flame trench after every launch - although this is not a direct indication of low life expectancy, it does indicate that the current system may not be sufficiently durable to maximize economy. Better performing refractory ceramics are needed to improve the performance, economy, and safety during and after launches at the flame trenches at Kennedy Space Center (KSC). To achieve this goal a current study is underway to assess different refractory systems for possible use in the flame trenches at KSC. This report will target the potential applicability of refractory ceramics for use in the flame trenches. An overview of the different refractory ceramics will be provided (see Figure I). This will be followed with a brief description of the structure of refractory products, the properties and characteristics of different systems, the methodology for selecting refractories, and then a general design methodology. Based on these sections, future challenges and opportunities will be identified with the objective of improving the durability, performance, economy, and safety of the launch complex. Refractory ceramics are used for a wide variety of applications. Figure 2 shows many ofthese applications, their life expectancy or requirement, and the exposure temperature for the refractory ceramic. Note that the exposure temperatures for refractory ceramics are very similar to the exposure conditions for specialty ceramics (rocket nozzles, space vehicle re-entry fields, etc.) and yet the life expectancy or requirement is relatively low. Currently NASA is repairing the refractory lining in the flame trench after every launch - although this is not a direct indication of low life expectancy, it does indicate that the current system may not be sufficiently durable to maximize economy. Better performing refractory ceramics are needed to improve the performance, economy, and safety during and after launches at the flame trenches at Kennedy Space Center (KSC). To achieve this goal a current study is underway to assess different refractory systems for possible use in the flame trenches at KSC. This report will target the potential applicability of refractory ceramics for use in the flame trenches. An overview of the different refractory ceramics will be provided (see Figure I). This will be followed with a brief description of the structure of refractory products, the properties and characteristics of different systems, the methodology for selecting refractories, and then a general design methodology. Based on these sections, future challenges and opportunities will be identified with the objective of improving the durability, performance, economy, and safety of the launch complex.
Neuronal nonlinearity explains greater visual spatial resolution for darks than lights.
Kremkow, Jens; Jin, Jianzhong; Komban, Stanley J; Wang, Yushi; Lashgari, Reza; Li, Xiaobing; Jansen, Michael; Zaidi, Qasim; Alonso, Jose-Manuel
2014-02-25
Astronomers and physicists noticed centuries ago that visual spatial resolution is higher for dark than light stimuli, but the neuronal mechanisms for this perceptual asymmetry remain unknown. Here we demonstrate that the asymmetry is caused by a neuronal nonlinearity in the early visual pathway. We show that neurons driven by darks (OFF neurons) increase their responses roughly linearly with luminance decrements, independent of the background luminance. However, neurons driven by lights (ON neurons) saturate their responses with small increases in luminance and need bright backgrounds to approach the linearity of OFF neurons. We show that, as a consequence of this difference in linearity, receptive fields are larger in ON than OFF thalamic neurons, and cortical neurons are more strongly driven by darks than lights at low spatial frequencies. This ON/OFF asymmetry in linearity could be demonstrated in the visual cortex of cats, monkeys, and humans and in the cat visual thalamus. Furthermore, in the cat visual thalamus, we show that the neuronal nonlinearity is present at the ON receptive field center of ON-center neurons and ON receptive field surround of OFF-center neurons, suggesting an origin at the level of the photoreceptor. These results demonstrate a fundamental difference in visual processing between ON and OFF channels and reveal a competitive advantage for OFF neurons over ON neurons at low spatial frequencies, which could be important during cortical development when retinal images are blurred by immature optics in infant eyes.
Design and realization of an AEC&AGC system for the CCD aerial camera
NASA Astrophysics Data System (ADS)
Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun
2015-08-01
An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.
Earth Resources Technology Satellite Operations Control Center (OCC). ERTS-B flight activation plan
NASA Technical Reports Server (NTRS)
1974-01-01
Included in this plan are general objectives through Day 7, operational guidelines and restraints. Following the activation of all subsystems (through Day 3), special series of payload operations were performed to obtain data samples for the different combinations of exposure/gain settings. This took place from Day 4 through Day 7. The Orbit Adjust was employed to perform vernier corrections after the orbit had been defined. The orbit data was collected through Day 3, with the corrections being made from Day 4 through Day 7. ERTS command auxiliary memory (ECAM) was turned on in Day 3 and the memory dumped to a narrow band tape recorder. A verification of memory was done in the off line mode. ECAM was not used in a payload support mode until Day 7.
Junhong, Huang; Renlai, Zhou; Senqi, Hu
2013-01-01
Two experiments were conducted to investigate the automatic processing of emotional facial expressions while performing low or high demand cognitive tasks under unattended conditions. In Experiment 1, 35 subjects performed low (judging the structure of Chinese words) and high (judging the tone of Chinese words) cognitive load tasks while exposed to unattended pictures of fearful, neutral, or happy faces. The results revealed that the reaction time was slower and the performance accuracy was higher while performing the low cognitive load task than while performing the high cognitive load task. Exposure to fearful faces resulted in significantly longer reaction times and lower accuracy than exposure to neutral faces on the low cognitive load task. In Experiment 2, 26 subjects performed the same word judgment tasks and their brain event-related potentials (ERPs) were measured for a period of 800 ms after the onset of the task stimulus. The amplitudes of the early component of ERP around 176 ms (P2) elicited by unattended fearful faces over frontal-central-parietal recording sites was significantly larger than those elicited by unattended neutral faces while performing the word structure judgment task. Together, the findings of the two experiments indicated that unattended fearful faces captured significantly more attention resources than unattended neutral faces on a low cognitive load task, but not on a high cognitive load task. It was concluded that fearful faces could automatically capture attention if residues of attention resources were available under the unattended condition.
Junhong, Huang; Renlai, Zhou; Senqi, Hu
2013-01-01
Two experiments were conducted to investigate the automatic processing of emotional facial expressions while performing low or high demand cognitive tasks under unattended conditions. In Experiment 1, 35 subjects performed low (judging the structure of Chinese words) and high (judging the tone of Chinese words) cognitive load tasks while exposed to unattended pictures of fearful, neutral, or happy faces. The results revealed that the reaction time was slower and the performance accuracy was higher while performing the low cognitive load task than while performing the high cognitive load task. Exposure to fearful faces resulted in significantly longer reaction times and lower accuracy than exposure to neutral faces on the low cognitive load task. In Experiment 2, 26 subjects performed the same word judgment tasks and their brain event-related potentials (ERPs) were measured for a period of 800 ms after the onset of the task stimulus. The amplitudes of the early component of ERP around 176 ms (P2) elicited by unattended fearful faces over frontal-central-parietal recording sites was significantly larger than those elicited by unattended neutral faces while performing the word structure judgment task. Together, the findings of the two experiments indicated that unattended fearful faces captured significantly more attention resources than unattended neutral faces on a low cognitive load task, but not on a high cognitive load task. It was concluded that fearful faces could automatically capture attention if residues of attention resources were available under the unattended condition. PMID:24124486
NASA Astrophysics Data System (ADS)
Patton, J.; Yeck, W.; Benz, H.
2017-12-01
The U.S. Geological Survey National Earthquake Information Center (USGS NEIC) is implementing and integrating new signal detection methods such as subspace correlation, continuous beamforming, multi-band picking and automatic phase identification into near-real-time monitoring operations. Leveraging the additional information from these techniques help the NEIC utilize a large and varied network on local to global scales. The NEIC is developing an ordered, rapid, robust, and decentralized framework for distributing seismic detection data as well as a set of formalized formatting standards. These frameworks and standards enable the NEIC to implement a seismic event detection framework that supports basic tasks, including automatic arrival time picking, social media based event detections, and automatic association of different seismic detection data into seismic earthquake events. In addition, this framework enables retrospective detection processing such as automated S-wave arrival time picking given a detected event, discrimination and classification of detected events by type, back-azimuth and slowness calculations, and ensuring aftershock and induced sequence detection completeness. These processes and infrastructure improve the NEIC's capabilities, accuracy, and speed of response. In addition, this same infrastructure provides an improved and convenient structure to support access to automatic detection data for both research and algorithmic development.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Chesapeake Bay off Fort Monroe, Virginia; restricted area, U.S. Naval Base and Naval Surface Weapon Center. 334.360 Section 334.360....S. Naval Base and Naval Surface Weapon Center. (a) The area. Beginning at latitude 37°01′03...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Chesapeake Bay off Fort Monroe, Virginia; restricted area, U.S. Naval Base and Naval Surface Weapon Center. 334.360 Section 334.360....S. Naval Base and Naval Surface Weapon Center. (a) The area. Beginning at latitude 37°01′03...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Chesapeake Bay off Fort Monroe, Virginia; restricted area, U.S. Naval Base and Naval Surface Weapon Center. 334.360 Section 334.360....S. Naval Base and Naval Surface Weapon Center. (a) The area. Beginning at latitude 37°01′03...
ERIC Educational Resources Information Center
McKnight, Carolyn P.
2012-01-01
This qualitative, multi-case study was designed to examine off-campus centers and their administrators in creating an effective learning environment for adult learners. Serving as the conceptual framework, invitational leadership theory is a holistic approach which nurtures the belief that everyone is intrinsically motivated and it is the leaders'…
ERIC Educational Resources Information Center
McKnight, Carolyn P.; Martin, Barbara N.
2015-01-01
This study was designed to examine off-campus centers and their administrators in creating an effective learning environment for adult learners using a new innovative leadership theory, invitational, which is a holistic approach that nurtures the belief everyone is intrinsically motivated and it is the leaders' responsibility to unleash their true…
Reinecke, Andrea; Waldenmaier, Lara; Cooper, Myra J; Harmer, Catherine J
2013-06-01
Cognitive behavioral therapy (CBT) is an effective treatment for emotional disorders such as anxiety or depression, but the mechanisms underlying successful intervention are far from understood. Although it has been a long-held view that psychopharmacological approaches work by directly targeting automatic emotional information processing in the brain, it is usually postulated that psychological treatments affect these processes only over time, through changes in more conscious thought cycles. This study explored the role of early changes in emotional information processing in CBT action. Twenty-eight untreated patients with panic disorder were randomized to a single session of exposure-based CBT or waiting group. Emotional information processing was measured on the day after intervention with an attentional visual probe task, and clinical symptoms were assessed on the day after intervention and at 4-week follow-up. Vigilance for threat information was decreased in the treated group, compared with the waiting group, the day after intervention, before reductions in clinical symptoms. The magnitude of this early effect on threat vigilance predicted therapeutic response after 4 weeks. Cognitive behavioral therapy rapidly affects automatic processing, and these early effects are predictive of later therapeutic change. Such results suggest very fast action on automatic processes mediating threat sensitivity, and they provide an early marker of treatment response. Furthermore, these findings challenge the notion that psychological treatments work directly on conscious thought processes before automatic information processing and imply a greater similarity between early effects of pharmacological and psychological treatments for anxiety than previously thought. Copyright © 2013 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, J; Liu, X
2016-06-15
Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. Wemore » investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.« less
Otake, Y.; Schafer, S.; Stayman, J. W.; Zbijewski, W.; Kleinszig, G.; Graumann, R.; Khanna, A. J.; Siewerdsen, J. H.
2012-01-01
Surgical targeting of the incorrect vertebral level (“wrong-level” surgery) is among the more common wrong-site surgical errors, attributed primarily to a lack of uniquely identifiable radiographic landmarks in the mid-thoracic spine. Conventional localization method involves manual counting of vertebral bodies under fluoroscopy, is prone to human error, and carries additional time and dose. We propose an image registration and visualization system (referred to as LevelCheck), for decision support in spine surgery by automatically labeling vertebral levels in fluoroscopy using a GPU-accelerated, intensity-based 3D-2D (viz., CT-to-fluoroscopy) registration. A gradient information (GI) similarity metric and CMA-ES optimizer were chosen due to their robustness and inherent suitability for parallelization. Simulation studies involved 10 patient CT datasets from which 50,000 simulated fluoroscopic images were generated from C-arm poses selected to approximate C-arm operator and positioning variability. Physical experiments used an anthropomorphic chest phantom imaged under real fluoroscopy. The registration accuracy was evaluated as the mean projection distance (mPD) between the estimated and true center of vertebral levels. Trials were defined as successful if the estimated position was within the projection of the vertebral body (viz., mPD < 5mm). Simulation studies showed a success rate of 99.998% (1 failure in 50,000 trials) and computation time of 4.7 sec on a midrange GPU. Analysis of failure modes identified cases of false local optima in the search space arising from longitudinal periodicity in vertebral structures. Physical experiments demonstrated robustness of the algorithm against quantum noise and x-ray scatter. The ability to automatically localize target anatomy in fluoroscopy in near-real-time could be valuable in reducing the occurrence of wrong-site surgery while helping to reduce radiation exposure. The method is applicable beyond the specific case of vertebral labeling, since any structure defined in pre-operative (or intra-operative) CT or cone-beam CT can be automatically registered to the fluoroscopic scene. PMID:22864366
Reevaluation of pollen quantitation by an automatic pollen counter.
Muradil, Mutarifu; Okamoto, Yoshitaka; Yonekura, Syuji; Chazono, Hideaki; Hisamitsu, Minako; Horiguchi, Shigetoshi; Hanazawa, Toyoyuki; Takahashi, Yukie; Yokota, Kunihiko; Okumura, Satoshi
2010-01-01
Accurate and detailed pollen monitoring is useful for selection of medication and for allergen avoidance in patients with allergic rhinitis. Burkard and Durham pollen samplers are commonly used, but are labor and time intensive. In contrast, automatic pollen counters allow simple real-time pollen counting; however, these instruments have difficulty in distinguishing pollen from small nonpollen airborne particles. Misidentification and underestimation rates for an automatic pollen counter were examined to improve the accuracy of the pollen count. The characteristics of the automatic pollen counter were determined in a chamber study with exposure to cedar pollens or soil grains. The cedar pollen counts were monitored in 2006 and 2007, and compared with those from a Durham sampler. The pollen counts from the automatic counter showed a good correlation (r > 0.7) with those from the Durham sampler when pollen dispersal was high, but a poor correlation (r < 0.5) when pollen dispersal was low. The new correction method, which took into account the misidentification and underestimation, improved this correlation to r > 0.7 during the pollen season. The accuracy of automatic pollen counting can be improved using a correction to include rates of underestimation and misidentification in a particular geographical area.
Kirschman, Lucas J; Crespi, Erica J; Warne, Robin W
2018-01-01
Ubiquitous environmental stressors are often thought to alter animal susceptibility to pathogens and contribute to disease emergence. However, duration of exposure to a stressor is likely critical, because while chronic stress is often immunosuppressive, acute stress can temporarily enhance immune function. Furthermore, host susceptibility to stress and disease often varies with ontogeny; increasing during critical developmental windows. How the duration and timing of exposure to stressors interact to shape critical windows and influence disease processes is not well tested. We used ranavirus and larval amphibians as a model system to investigate how physiological stress and pathogenic infection shape development and disease dynamics in vertebrates. Based on a resource allocation model, we designed experiments to test how exposure to stressors may induce resource trade-offs that shape critical windows and disease processes because the neuroendocrine stress axis coordinates developmental remodelling, immune function and energy allocation in larval amphibians. We used wood frog larvae (Lithobates sylvaticus) to investigate how chronic and acute exposure to corticosterone, the dominant amphibian glucocorticoid hormone, mediates development and immune function via splenocyte immunohistochemistry analysis in association with ranavirus infection. Corticosterone treatments affected immune function, as both chronic and acute exposure suppressed splenocyte proliferation, although viral replication rate increased only in the chronic corticosterone treatment. Time to metamorphosis and survival depended on both corticosterone treatment and infection status. In the control and chronic corticosterone treatments, ranavirus infection decreased survival and delayed metamorphosis, although chronic corticosterone exposure accelerated rate of metamorphosis in uninfected larvae. Acute corticosterone exposure accelerated metamorphosis increased survival in infected larvae. Interactions between stress exposure (via glucocorticoid actions) and infection impose resource trade-offs that shape optimal allocation between development and somatic function. As a result, critical disease windows are likely shaped by stress exposure because any conditions that induce changes in differentiation rates will alter the duration and susceptibility of organisms to stressors or disease. © 2017 The Authors. Journal of Animal Ecology © 2017 British Ecological Society.
Midline and off-midline infratentorial supracerebellar approaches to the pineal gland.
Matsuo, Satoshi; Baydin, Serhat; Güngör, Abuzer; Miki, Koichi; Komune, Noritaka; Kurogi, Ryota; Iihara, Koji; Rhoton, Albert L
2017-06-01
OBJECTIVE A common approach to lesions of the pineal region is along the midline below the torcula. However, reports of how shifting the approach off midline affects the surgical exposure and relationships between the tributaries of the vein of Galen are limited. The purpose of this study is to examine the microsurgical and endoscopic anatomy of the pineal region as seen through the supracerebellar infratentorial approaches, including midline, paramedian, lateral, and far-lateral routes. METHODS The quadrigeminal cisterns of 8 formalin-fixed adult cadaveric heads were dissected and examined with the aid of a surgical microscope and straight endoscope. Twenty CT angiograms were examined to measure the depth of the pineal gland, slope of the tentorial surface of the cerebellum, and angle of approach to the pineal gland in each approach. RESULTS The midline supracerebellar route is the shortest and provides direct exposure of the pineal gland, although the culmen and inferior and superior vermian tributaries of the vein of Galen frequently block this exposure. The off-midline routes provide a surgical exposure that, although slightly deeper, may reduce the need for venous sacrifice at both the level of the veins from the superior cerebellar surface entering the tentorial sinuses and at the level of the tributaries of the vein of Galen in the quadrigeminal cistern, and require less cerebellar retraction. Shifting from midline to off-midline exposure also provides a better view of the cerebellomesencephalic fissure, collicular plate, and trochlear nerve than the midline approaches. Endoscopic assistance may aid exposure of the pineal gland while preserving the bridging veins. CONCLUSIONS Understanding the characteristics of different infratentorial routes to the pineal gland will aid in gaining a better view of the pineal gland and cerebellomesencephalic fissure and may reduce the need for venous sacrifice at the level of the tentorial sinuses draining the upper cerebellar surface and the tributaries of the vein of Galen.
SIMULATING LOCAL DENSE AREAS USING PMMA TO ASSESS AUTOMATIC EXPOSURE CONTROL IN DIGITAL MAMMOGRAPHY.
Bouwman, R W; Binst, J; Dance, D R; Young, K C; Broeders, M J M; den Heeten, G J; Veldkamp, W J H; Bosmans, H; van Engen, R E
2016-06-01
Current digital mammography (DM) X-ray systems are equipped with advanced automatic exposure control (AEC) systems, which determine the exposure factors depending on breast composition. In the supplement of the European guidelines for quality assurance in breast cancer screening and diagnosis, a phantom-based test is included to evaluate the AEC response to local dense areas in terms of signal-to-noise ratio (SNR). This study evaluates the proposed test in terms of SNR and dose for four DM systems. The glandular fraction represented by the local dense area was assessed by analytic calculations. It was found that the proposed test simulates adipose to fully glandular breast compositions in attenuation. The doses associated with the phantoms were found to match well with the patient dose distribution. In conclusion, after some small adaptations, the test is valuable for the assessment of the AEC performance in terms of both SNR and dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2014 CFR
2014-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2013 CFR
2013-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2011 CFR
2011-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2012 CFR
2012-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
77 FR 15843 - Petition for Exemption From the Vehicle Theft Prevention Standard; Nissan
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
... vehicle and the vehicle itself from being stolen when the back door and all of the side doors are closed... automatically when the ignition key is turned to the ``OFF'' position and all the doors are closed and locked through the use of the key or the remote control mechanism. Deactivation occurs when all the doors are...
Datasets of Odontocete Sounds Annotated for Developing Automatic Detection Methods
2010-12-01
Passive acoustic detection of Minke whales (Balaenoptera acutorostrata) off the West Coast of Kauai, HI. Book of abstracts, Fourth International...Workshop on Detection , Classification and Localization of Marine Mammals using Passive Acoustics , Pavia, Italy, Sept. 10- 13, 2009, p. 57. Roch, M., Y...Mellinger, and D. Gillespie. 2010. Comparison of beaked whale detection algorithms. Applied Acoustics 71:1043-1049. 8 References
ERIC Educational Resources Information Center
Alfonseca, Enrique; Rodriguez, Pilar; Perez, Diana
2007-01-01
This work describes a framework that combines techniques from Adaptive Hypermedia and Natural Language processing in order to create, in a fully automated way, on-line information systems from linear texts in electronic format, such as textbooks. The process is divided into two steps: an "off-line" processing step, which analyses the source text,…
Peels, Hans O; de Swart, Hans; Ploeg, Tjeerd V D; Hautvast, Raymond W; Cornel, Jan H; Arnold, Alf E; Wharton, Thomas P; Umans, Victor A
2007-11-01
We investigated whether primary percutaneous coronary intervention (PCI) for patients admitted with an acute ST-segment elevation myocardial infarction could be performed more rapidly and with comparable outcomes in a community hospital versus a tertiary center with cardiac surgery. We started the first PCI with an off-site surgery program in The Netherlands in 2002 and report the results of 439 consecutive patients. In the safety phase, 199 patients presenting with ST-segment elevation myocardial infarction were randomly assigned to treatment at our off-site center versus a more distant cardiac surgery center. In the confirmation phase, 240 consecutive patients were treated in the off-site hospital. Safety and efficacy end points were the rate of an angiographically successful PCI procedure (diameter stenosis <50% and Thrombolysis In Myocardial Infarction grade 3 flow) in the absence of major adverse cardiac and cerebrovascular events at 30 days. The randomization phase showed a 37-minute decrease in door-to-balloon time (p <0.001) with comparable procedural and clinical successes (91% Thrombolysis In Myocardial Infarction grade 3 flow in the 2 groups). In the confirmation phase, the 30-day rate without major adverse cardiac and cerebrovascular events was 95%. None of the 439 patients in the study required emergency surgery for failed primary PCI. In conclusion, time to treatment with primary PCI can be significantly shortened when treating patients in a community hospital setting with off-site cardiac surgery backup compared with transport for PCI to a referral center with on-site surgery. PCI at hospitals with off-site cardiac surgery backup can be considered a needed strategy to improve access to primary PCI for a larger segment of the population and can be delivered with a very favorable safety profile.
de Groot, Stefan; de Winter, Joost C F; López García, José Manuel; Mulder, Max; Wieringa, Peter A
2011-02-01
The aim of this study was to investigate whether concurrent bandwidth feedback improves learning of the lane-keeping task in a driving simulator. Previous research suggests that bandwidth feedback improves learning and that off-target feedback is superior to on-target feedback. This study aimed to extend these findings for the lane-keeping task. Participants without a driver's license drove five 8-min lane-keeping sessions in a driver training simulator: three practice sessions, an immediate retention session, and a delayed retention session I day later. There were four experimental groups (n=15 per group): (a) on-target, receiving seat vibrations when the center of the car was within 0.5 m of the lane center; (b) off-target, receiving seat vibrations when the center of the car was more than 0.5 m away from the lane center; (c) control, receiving no vibrations; and (d) realistic, receiving seat vibrations depending on engine speed. During retention, all groups were provided with the realistic vibrations. During practice, on-target and off-target groups had better lane-keeping performance than the nonaugmented groups, but this difference diminished in the retention phase. Furthermore, during late practice and retention, the off-target group outperformed the on-target group.The off-target group had a higher rate of steering reversal and higher steering entropy than the nonaugmented groups, whereas no clear group differences were found regarding mean speed, mental workload, or self-reported measures. Off-target feedback is superior to on-target feedback for learning the lane-keeping task. This research provides knowledge to researchers and designers of training systems about the value of feedback in simulator-based training of vehicular control.
NASA Astrophysics Data System (ADS)
Sakkas, Georgios; Sakellariou, Nikolaos
2018-05-01
Strong motion recordings are the key in many earthquake engineering applications and are also fundamental for seismic design. The present study focuses on the automated correction of accelerograms, analog and digital. The main feature of the proposed algorithm is the automatic selection for the cut-off frequencies based on a minimum spectral value in a predefined frequency bandwidth, instead of the typical signal-to-noise approach. The algorithm follows the basic steps of the correction procedure (instrument correction, baseline correction and appropriate filtering). Besides the corrected time histories, Peak Ground Acceleration, Peak Ground Velocity, Peak Ground Displacement values and the corrected Fourier Spectra are also calculated as well as the response spectra. The algorithm is written in Matlab environment, is fast enough and can be used for batch processing or in real-time applications. In addition, the possibility to also perform a signal-to-noise ratio is added as well as to perform causal or acausal filtering. The algorithm has been tested in six significant earthquakes (Kozani-Grevena 1995, Aigio 1995, Athens 1999, Lefkada 2003 and Kefalonia 2014) of the Greek territory with analog and digital accelerograms.
Multistate metadynamics for automatic exploration of conical intersections
NASA Astrophysics Data System (ADS)
Lindner, Joachim O.; Röhr, Merle I. S.; Mitrić, Roland
2018-05-01
We introduce multistate metadynamics for automatic exploration of conical intersection seams between adiabatic Born-Oppenheimer potential energy surfaces in molecular systems. By choosing the energy gap between the electronic states as a collective variable the metadynamics drives the system from an arbitrary ground-state configuration toward the intersection seam. Upon reaching the seam, the multistate electronic Hamiltonian is extended by introducing biasing potentials into the off-diagonal elements, and the molecular dynamics is continued on a modified potential energy surface obtained by diagonalization of the latter. The off-diagonal bias serves to locally open the energy gap and push the system to the next intersection point. In this way, the conical intersection energy landscape can be explored, identifying minimum energy crossing points and the barriers separating them. We illustrate the method on the example of furan, a prototype organic molecule exhibiting rich photophysics. The multistate metadynamics reveals plateaus on the conical intersection energy landscape from which the minimum energy crossing points with characteristic geometries can be extracted. The method can be combined with the broad spectrum of electronic structure methods and represents a generally applicable tool for the exploration of photophysics and photochemistry in complex molecules and materials.
Automatic control study of the icing research tunnel refrigeration system
NASA Technical Reports Server (NTRS)
Kieffer, Arthur W.; Soeder, Ronald H.
1991-01-01
The Icing Research Tunnel (IRT) at the NASA Lewis Research Center is a subsonic, closed-return atmospheric tunnel. The tunnel includes a heat exchanger and a refrigeration plant to achieve the desired air temperature and a spray system to generate the type of icing conditions that would be encountered by aircraft. At the present time, the tunnel air temperature is controlled by manual adjustment of freon refrigerant flow control valves. An upgrade of this facility calls for these control valves to be adjusted by an automatic controller. The digital computer simulation of the IRT refrigeration plant and the automatic controller that was used in the simulation are discussed.
Sonic Booms in Atmospheric Turbulence (SonicBAT) Testing
2017-08-23
A motorized glider prepares to take off from the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. Flying with its engine off, the glider will be positioned above the 14,000-foot level to measure sonic booms created by agency F-18 jets to measure the effects of sonic booms. Several flights a day have been taking place the week of Aug. 21, 2017 as part of NASA's Sonic Booms in Atmospheric Turbulence, or SonicBAT II Program. NASA at Kennedy is partnering with the agency's Armstrong Flight Research Center in California, Langley Research Center in Virginia, and Space Florida for a program in which F-18 jets will take off from the Shuttle Landing Facility and fly at supersonic speeds while agency researchers measure the effects of low-altitude turbulence caused by sonic booms.
Sonic Booms in Atmospheric Turbulence (SonicBAT) Testing
2017-08-23
A motorized glider has taken off from the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. Flying with its engine off, the glider will be positioned above the 14,000-foot level to measure sonic booms created by agency F-18 jets to measure the effects of sonic booms. Several flights a day have been taking place the week of Aug. 21, 2017 as part of NASA's Sonic Booms in Atmospheric Turbulence, or SonicBAT II Program. NASA at Kennedy is partnering with the agency's Armstrong Flight Research Center in California, Langley Research Center in Virginia, and Space Florida for a program in which F-18 jets will take off from the Shuttle Landing Facility and fly at supersonic speeds while agency researchers measure the effects of low-altitude turbulence caused by sonic booms.
ERIC Educational Resources Information Center
Smith, William A., Ed.
The papers given at the May 17-19 forum on Management of Information Analysis Centers held at the National Bureau of Standards in Gaithersburg, Md. are presented in four sessions separated by topic. Besides the welcoming remarks and the keynote address session 1 contains three general papers on information analysis centers and automatic data…
Automatic blood pressure measuring system (M091)
NASA Technical Reports Server (NTRS)
1977-01-01
The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.
Mowry, James B.; Spyker, Daniel A.; Cantilena, Louis R.; McMillan, Naya; Ford, Marsha
2014-01-01
ABSTRACT Background: This is the 31st Annual Report of the American Association of Poison Control Centers’ (AAPCC) National Poison Data System (NPDS). As of January 1, 2013, 57 of the nation's poison centers (PCs) uploaded case data automatically to NPDS. The upload interval was 8.08 [7.10, 11.63] (median [25%, 75%]) minutes, creating a near real-time national exposure and information database and surveillance system. Methodology: We analyzed the case data tabulating specific indices from NPDS. The methodology was similar to that of previous years. Where changes were introduced, the differences are identified. Poison center (PC) cases with medical outcomes of death were evaluated by a team of 38 medical and clinical toxicologist reviewers using an ordinal scale of 1–6 to assess the Relative Contribution to Fatality (RCF) of the exposure to the death. Results: In 2013, 3,060,122 closed encounters were logged by NPDS: 2,188,013 human exposures, 59,496 animal exposures, 806,347 information calls, 6,116 human-confirmed nonexposures, and 150 animal-confirmed nonexposures. Total encounters showed a 9.3% decline from 2012, while health care facility human exposure calls were essentially flat, decreasing by 0.1%.All information calls decreased 21.4% and health care facility (HCF) information calls decreased 8.5%, medication identification requests (drug ID) decreased 26.8%, and human exposures reported to US PCs decreased 3.8%. Human exposures with less serious outcomes have decreased 3.7% per year since 2008 while those with more serious outcomes (moderate, major or death) have increased by 4.7% per year since 2000. The top five substance classes most frequently involved in all human exposures were analgesics (11.5%), cosmetics/personal care products (7.7%), household cleaning substances (7.6%), sedatives/hypnotics/antipsychotics (5.9%), and antidepressants (4.2%). Sedative/hypnotics/antipsychotics exposures as a class increased most rapidly (2,559 calls/year) over the last 13 years for cases showing more serious outcomes. The top five most common exposures in children of 5 years or less were cosmetics/personal care products (13.8%), household cleaning substances (10.4%), analgesics (9.8%), foreign bodies/toys/miscellaneous (6.9%), and topical preparations (6.1%). Drug identification requests comprised 50.7% of all information calls. NPDS documented 2,477 human exposures resulting in death with 2,113 human fatalities judged related (RCF of 1, undoubtedly responsible; 2, probably responsible; or 3, contributory). Conclusions: These data support the continued value of PC expertise and need for specialized medical toxicology information to manage the more severe exposures, despite a decrease in calls involving less severe exposures. Unintentional and intentional exposures continue to be a significant cause of morbidity and mortality in the United States. The near real-time, always current status of NPDS represents a national public health resource to collect and monitor US exposure cases and information calls. The continuing mission of NPDS is to provide a nationwide infrastructure for public health surveillance for all types of exposures, public health event identification, resilience response and situational awareness tracking. NPDS is a model system for the nation and global public health. PMID:25559822
The Use and Value of Defense Technical Information Center Products and Services.
ERIC Educational Resources Information Center
Roderer, Nancy K.; And Others
This study describes the use and value of the major information products and services provided by the Defense Technical Information Center (DTIC). These products and services include technical report distribution on an on-demand basis and through the Automatic Document Distribution (ADD) program; secondary information dissemination through online…
NASA Technical Reports Server (NTRS)
Surkis, Igor; Ken, Voitsekh; Melnikov, Alexey; Mishin, Vladimir; Sokolova, Nadezda; Shantyr, Violet; Zimovsky, Vladimir
2013-01-01
The activities of the six-station IAA RAS correlator include regular processing of national geodetic VLBI programs Ru-E, Ru-U, and Ru-F. The Ru-U sessions have been transferred in e-VLBI mode and correlated in the IAA Correlator Center automatically since 2011. The DiFX software correlator is used at the IAA in some astrophysical experiments.
NASA Technical Reports Server (NTRS)
Hammond, E. C., Jr.; Peters, K. A.; Atkinson, P. F.
1986-01-01
Three canisters of IIaO film were prepared along with packets of color film from the National Geographic Society, which were then placed on the Space Shuttle #3. The ultimate goal was to obtain reasonably accurate data concerning the background fogging effects on IIaO film as it relates to the film's total environmental experience. This includes: the ground based packing, and loading of the film from Goddard Space Flight Center to Cape Kennedy; the effects of the solar wind, humidity, and cosmic rays; the Van Allen Belt radiation exposure; various thermal effect; reentry and off-loading of the film during take off, and 8 day, 3 hour 15 minutes orbits. The total densitometric change caused by all of the above factors were examined. The results of these studies have implications for the utilization of IIaO spectroscopic film on the future shuttle and space lab missions. These responses to standard photonic energy sources will have immediate application for the uneven responses of the film photographing a star field in a terrestrial or extraterrestrial environment with associated digital imaging equipment.
2003-10-27
KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, Bill Prosser (left) and Eric Madaras, NASA-Langley Research Center, conduct impulse tests on the right wing leading edge (WLE) of Space Shuttle Endeavour. The tests monitor how sound impulses propagate through the WLE area. The data collected will be analyzed to explore the possibility of adding new instrumentation to the wing that could automatically detect debris or micrometeroid impacts on the Shuttle while in flight. The study is part of the initiative ongoing at KSC and around the agency to return the orbiter fleet to flight status.
Healthy people with nature in mind.
Annerstedt van den Bosch, Matilda; Depledge, Michael H
2015-12-11
The global disease burden resulting from climate change is likely to be substantial and will put further strain on public health systems that are already struggling to cope with demand. An up- stream solution, that of preventing climate change and associated adverse health effects, is a promising approach, which would create win-win-situations where both the environment and human health benefit. One such solution would be to apply methods of behaviour change to prompt pro-environmentalism, which in turn benefits health and wellbeing. Based on evidence from the behavioural sciences, we suggest that, like many social behaviours, pro- environmental behaviour can be automatically induced by internal or external stimuli. A potential trigger for such automatic pro-environmental behaviour would be natural environments themselves. Previous research has demonstrated that natural environments evoke specific psychological and physiological reactions, as demonstrated by self-reports, epidemiological studies, brain imaging techniques, and various biomarkers. This suggests that exposure to natural environments could have automatic behavioural effects, potentially in a pro-environmental direction, mediated by physiological reactions. Providing access and fostering exposure to natural environments could then serve as a public health tool, together with other measures, by mitigating climate change and achieving sustainable health in sustainable ecosystems. However, before such actions are implemented basic research is required to elucidate the mechanisms involved, and applied investigations are needed to explore real world impacts and effect magnitudes. As environmental research is still not sufficiently integrated within medical or public health studies there is an urgent need to promote interdisciplinary methods and investigations in this critical field. Health risks posed by anthropogenic climate change are large, unevenly distributed, and unpredictable. To ameliorate negative impacts, pro-environmental behaviours should be fostered. Potentially this could be achieved automatically through exposure to favourable natural environments, with an opportunity for cost-efficient nature-based solutions that provide benefits for both the environment and public health.
A biomechanical analysis of the long-jump technique of elite female amputee athletes.
Nolan, Lee; Patritti, Benjamin L; Simpson, Kathy J
2006-10-01
The purpose of this study was to investigate whether female lower-limb amputees conform to the established long-jump model and to compare the kinematics of the approach and take-off phases for elite female transfemoral and transtibial amputee long jumpers. Eight female transfemoral and nine female transtibial amputee athletes were videotaped (sagittal plane movements at 50 Hz) from third-to-last step to take-off during the 2004 Paralympic Games long-jump finals. After digitizing and reconstruction of 2D coordinates, key variables were calculated at each stride and during contact with the take-off board. Additionally, approach speed during the run-up of each jump was recorded (100 Hz) using a laser Doppler device (LDM 300 C Sport, Jenoptik Laser, Jena, Germany). The transfemoral amputees had a consistently higher center of mass height on the last three steps before take-off than the transtibial amputees. However, at touch-down onto the take-off board, they lowered their center of mass excessively so that from touch-down to take-off, they were actually lower than the transtibial amputees. This resulted in a greater negative vertical velocity at touch-down and may have inversely affected their jump performance. Female transtibial athletes conformed to the long-jump model, although adaptations to this technique were displayed. Female transfemoral athletes, however, exhibited no relationship between take-off speed and distance jumped, which may be attributable to their excessive lowering of their center-of-mass height at touch-down onto the take-off board. It is recommended that coaches and athletes proceed with caution when trying to replicate techniques used by able-bodied athletes because adaptations to the constraints of a prosthesis should be considered.
EPA CENTER FOR EXPOSURE ASSESSMENT MODELING (CEAM)
The EPA Center for Exposure Assessment Modeling (CEAM) supports the Agency and professional community in environmental, risk-based decision-making by expanding their applications expertise for quantitatively assessing pollutant exposure via aquatic, terrestrial, and multimedia pa...
2007-07-01
NASA's modified Boeing 747 Shuttle Carrier Aircraft with the Space Shuttle Atlantis on top lifts off from Edwards Air Force Base to begin its ferry flight back to the Kennedy Space Center in Florida. The cross-country journey will take approximately two days, with stops at several intermediate points for refueling.
Jones, Travis M; Drew, Richard H; Wilson, Dustin T; Sarubbi, Christina; Anderson, Deverick J
2017-12-01
The impact of automatic infectious diseases (ID) consultation for inpatients with fungemia at a large academic medical center was studied. In this single-center, retrospective study, the time to appropriate antifungal therapy before and after implementing a policy requiring automatic ID consultation for the management of fungemia for all patients with an inpatient positive blood culture for fungus was examined. The rates of ID consultation; the likelihood of receiving appropriate antifungal therapy; central venous catheter (CVC) removal rates; performance of ophthalmologic examinations; infection-related length of stay (LOS); rates of all-cause inhospital mortality, death, or transfer to an intensive care unit within 7 days of first culture; and inpatient cost of antifungals were also evaluated. A total of 173 unique episodes (94 and 79 in the control and intervention groups, respectively) were included. Candida species were the most frequently cultured organisms, isolated from over 90% of patients in both groups. No differences were observed between the control and intervention groups in time to appropriate therapy, infection-related LOS, or time to CVC removal. However, patients in the intervention group were more likely than those in the control group to receive appropriate antifungal therapy ( p = 0.0392), undergo ophthalmologic examination ( p = 0.003), have their CVC removed ( p = 0.0038), and receive ID consultation ( p = 0.0123). Inpatient antifungal costs were significantly higher in the intervention group ( p = 0.0177). While automatic ID consultation for inpatients with fungemia did not affect the time to administration of appropriate therapy, improvement was observed for several process indicators, including rates of appropriate antifungal therapy selection, time to removal of CVCs, and performance of ophthalmologic examinations. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Wu, Ping; Duarte, Cristiane S.; Mandell, Donald J.; Fan, Bin; Liu, Xinhua; Fuller, Cordelia J.; Musa, George; Cohen, Michael; Cohen, Patricia; Hoven, Christina W.
2006-01-01
We examined exposure to the World Trade Center attack and changes in cigarette smoking and drinking among 2731 New York City public high-school students evaluated 6 months after the attack. Increased drinking was associated with direct exposure to the World Trade Center attack (P < .05). Increased smoking was not directly associated with exposure to the World Trade Center attack but was marginally significantly associated with posttraumatic stress disorder (P= .06). Our findings suggest that targeted substance-use interventions for youths may be warranted after large-scale disasters. PMID:16571705
Attention and reach-to-grasp movements in Parkinson's disease.
Lu, Cathy; Bharmal, Aamir; Kiss, Zelma H; Suchowersky, Oksana; Haffenden, Angela M
2010-08-01
The role of attention in grasping movements directed at common objects has not been examined in Parkinson's disease (PD), though these movements are critical to activities of daily living. Our primary objective was to determine whether patients with PD demonstrate automaticity in grasping movements directed toward common objects. Automaticity is assumed when tasks can be performed with little or no interference from concurrent tasks. Grasping performance in three patient groups (newly diagnosed, moderate, and advanced/surgically treated PD) on and off of their medication or deep brain stimulation was compared to performance in an age-matched control group. Automaticity was demonstrated by the absence of a decrement in grasping performance when attention was consumed by a concurrent spatial-visualization task. Only the control group and newly diagnosed PD group demonstrated automaticity in their grasping movements. The moderate and advanced PD groups did not demonstrate automaticity. Furthermore, the well-known effects of pharmacotherapy and surgical intervention on movement speed and muscle activation patterns did not appear to reduce the impact of attention-demanding tasks on grasping movements in those with moderate to advanced PD. By the moderate stage of PD, grasping is an attention-demanding process; this change is not ameliorated by dopaminergic or surgical treatments. These findings have important implications for activities of daily living, as devoting attention to the simplest of daily tasks would interfere with complex activities and potentially exacerbate fatigue.
NASA Technical Reports Server (NTRS)
Pamadi, Bandu N.; Pei, Jing; Covell, Peter F.; Favaregh, Noah M.; Gumbert, Clyde R.; Hanke, Jeremy L.
2011-01-01
NASA Langley Research Center, in partnership with NASA Marshall Space Flight Center and NASA Ames Research Center, was involved in the aerodynamic analyses, testing, and database development for the Ares I A106 crew launch vehicle in support of the Ares Design and Analysis Cycle. This paper discusses the development of lift-off/transition and ascent databases. The lift-off/transition database was developed using data from tests on a 1.75% scale model of the A106 configuration in the NASA Langley 14x22 Subsonic Wind Tunnel. The power-off ascent database was developed using test data on a 1% A106 scale model from two different facilities, the Boeing Polysonic Wind Tunnel and the NASA Langley Unitary Plan Wind Tunnel. The ascent database was adjusted for differences in wind tunnel and flight Reynolds numbers using USM3D CFD code. The aerodynamic jet interaction effects due to first stage roll control system were modeled using USM3D and OVERFLOW CFD codes.
Recent and long-term occupational noise exposure and salivary cortisol level.
Stokholm, Zara Ann; Hansen, Åse Marie; Grynderup, Matias Brødsgaard; Bonde, Jens Peter; Christensen, Kent Lodberg; Frederiksen, Thomas Winther; Lund, Søren Peter; Vestergaard, Jesper Medom; Kolstad, Henrik Albert
2014-01-01
Environmental and occupational noise exposure have been related to increased risk of cardiovascular disease, hypothetically mediated by stress-activation of the hypothalamic-pituitary-adrenal (HPA) axis. The objective of this study was to investigate the relation between recent and long-term occupational noise exposure and cortisol level measured off work to assess a possible sustained HPA-axis effect. We included 501 industrial, finance, and service workers who were followed for 24h during work, leisure, and sleep. Ambient occupational noise exposure levels were recorded every 5s by personal dosimeters and we calculated the full-shift LAEq value and estimated duration and cumulative exposure based on their work histories since 1980. For 332 workers who kept a log-book on the use of hearing protection devices (HPD), we subtracted 10 dB from every noise recording obtained during HPD use and estimated the noise level at the ear. Salivary cortisol concentration was measured at 20.00 h, the following day at awakening, and 30 min after awakening on average 5, 14 and 14.5h after finishing work. The mean ambient noise exposure level was 79.9 dB(A) [range: 55.0-98.9] and the mean estimated level at the ear 77.7 dB(A) [range: 55.0-94.2]. In linear and mixed regression models that adjusted for age, sex, current smoking, heavy alcohol consumption, personal income, BMI, leisure-time noise exposure level, time since occupational noise exposure ceased, awakening time, and time of saliva sampling, we observed no statistically significant exposure response relation between recent, or long-term ambient occupational noise exposure level and any cortisol parameter off work. This was neither the case for recent noise level at the ear. To conclude, neither recent nor long-term occupational noise exposure levels were associated with increased cortisol level off work. Thus, our results do not indicate that a sustained activation of the HPA axis, as measured by cortisol, is involved in the causal pathway between occupational noise exposure and cardiovascular disease. Copyright © 2013 Elsevier Ltd. All rights reserved.
Study of smartphone suitability for mapping of skin chromophores
NASA Astrophysics Data System (ADS)
Kuzmina, Ilona; Lacis, Matiss; Spigulis, Janis; Berzina, Anna; Valeine, Lauma
2015-09-01
RGB (red-green-blue) technique for mapping skin chromophores by smartphones is proposed and studied. Three smartphones of different manufacturers were tested on skin phantoms and in vivo on benign skin lesions using a specially designed light source for illumination. Hemoglobin and melanin indices obtained by these smartphones showed differences in both tests. In vitro tests showed an increment of hemoglobin and melanin indices with the concentration of chromophores in phantoms. In vivo tests indicated higher hemoglobin index in hemangiomas than in nevi and healthy skin, and nevi showed higher melanin index compared to the healthy skin. Smartphones that allow switching off the automatic camera settings provided useful data, while those with "embedded" automatic settings appear to be useless for distant skin chromophore mapping.
Study of smartphone suitability for mapping of skin chromophores.
Kuzmina, Ilona; Lacis, Matiss; Spigulis, Janis; Berzina, Anna; Valeine, Lauma
2015-09-01
RGB (red-green-blue) technique for mapping skin chromophores by smartphones is proposed and studied. Three smartphones of different manufacturers were tested on skin phantoms and in vivo on benign skin lesions using a specially designed light source for illumination. Hemoglobin and melanin indices obtained by these smartphones showed differences in both tests. In vitro tests showed an increment of hemoglobin and melanin indices with the concentration of chromophores in phantoms. In vivo tests indicated higher hemoglobin index in hemangiomas than in nevi and healthy skin, and nevi showed higher melanin index compared to the healthy skin. Smartphones that allow switching off the automatic camera settings provided useful data, while those with “embedded” automatic settings appear to be useless for distant skin chromophore mapping.
Automatic readout for nuclear emulsions in muon radiography of volcanoes
NASA Astrophysics Data System (ADS)
Aleksandrov, A.; Bozza, C.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Di Marco, N.; Kose, U.; Lauria, A.; Medinaceli, E.; Miyamoto, S.; Montesi, C.; Pupilli, F.; Rescigno, R.; Russo, A.; Sirignano, C.; Stellacci, S. M.; Strolin, P.; Tioukov, V.
2012-04-01
Nuclear emulsions are an effective choice in many scenarios of volcano radiography by cosmic-ray muons. They are cheap and emulsion-based detectors require no on-site power supply. Nuclear emulsion films provide sub-micrometric tracking precision and intrinsic angular accuracy better than 1 mrad. Imaging the inner structure of a volcano requires that the cosmic-ray absorption map be measured on wide angular range. High-absorption directions can be probed by allowing for large statistics, which implies a large overall flux, i.e. wide surface for the detector. A total area of the order of a few m2 is nowadays typical, thanks to the automatic readout tools originally developed for high-energy physics experiments such as CHORUS, PEANUT, OPERA. The European Scanning System is now being used to read out nuclear emulsion films exposed to cosmic rays on the side of volcanoes. The structure of the system is described in detail with respect to both hardware and software. Its present scanning speed of 20 cm2/h/side/microscope is suitable to fulfil the needs of the current exposures of nuclear emulsion films for muon radiograph, but it is worth to notice that applications in volcano imaging are among the driving forces pushing to increase the performances of the system. Preliminary results for the Unzen volcano of a joint effort by research groups in Italy and Japan show that the current system is already able to provide signal/background ratio in the range 100÷10000:1, depending on the quality cuts set in the off-line data analysis. The size of the smallest detectable structures in that experimental setup is constrained by the available statistics in the region of highest absorption to about 50 mrad, or 22 m under the top of the mountain. Another exposure is currently taking data at the Stromboli volcano. Readout of the exposed films is expected to begin in March 2012, and preliminary results will be available soon after. An effort by several universities and INFN has already started to increase the scanning speed, to exceed 100 cm2/h and approach the order of magnitude of 1000 cm2/h. Muon radiography also demands high signal/background ratio to probe high absorption regions in volcanoes. A new camera, a new image acquisition device, an improved motion control board and extensive use of GPU-based processing are the keys to make a new leap in speed while even improving data quality. With most of the new hardware already finalised, software development is quickly progressing, and a stable, user-friendly and cheap prototype is expected to be ready to take data already this summer. The amount of raw data collected is typically of the order of 10 TB/m2. The operation of automatic microscopes is thus complemented with an automatic data management and processing system based on a distributed computing model. The processing power can be scaled up linearly by just increasing the number of available computers. An evolution is underway on this side too, and algorithms designed for GPU-based processing will soon help increase the available power while decreasing the overall cost of typical installations.
Rapid Chemical Exposure and Dose Research
EPA evaluates the potential risks of the manufacture and use of thousands of chemicals. To assist with this evaluation, EPA scientists developed a rapid, automated model using off the shelf technology that predicts exposures for thousands of chemicals.
Active noise reduction in aviation helmets during a military jet trainer test flight.
Pääkkönen, R; Kuronen, P; Korteoja, M
2001-01-01
Cockpit noise measurements were carried out in a two-seat jet trainer. For the continuous time and frequency analyses a two-channel tape-recording system was constructed of two miniature microphones connected through an amplifier to a digital tape-recorder. The analysed and averaged noise exposure including radio communication was 80-81 dB when the ANC system was on and 84-89 dB when the ANC system was off. For the conventional flight helmet the same noise exposure was 86 dB, and the noise exposure in the cockpit was 104-106 dB. The effect of the ANC system on the averaged noise exposure (L(Aeq8min)) was an improvement of 4-8 dB over the noise attenuation of the same helmets when the ANC system was off. Both ANC systems worked properly during the test flights. No severe ringing or voice circulation was found except during extreme vibration.
Fluor Hanford ALARA Center is a D and D Resource
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waggoner, L.O.
2008-01-15
The mission at the Hanford Nuclear Reservation changed when the last reactor plant was shut down in 1989 and work was started to place all the facilities in a safe condition and begin decontamination, deactivation, decommissioning, and demolition (D and D). These facilities consisted of old shutdown reactor plants, spent fuel pools, processing facilities, and 177 underground tanks containing 53 million gallons of highly radioactive and toxic liquids and sludge. New skills were needed by the workforce to accomplish this mission. By 1995, workers were in the process of getting the facilities in a safe condition and it became obviousmore » improvements were needed in their tools, equipment and work practices. The Hanford ALARA Program looked good on paper, but did little to help contractors that were working in the field. The Radiological Control Director decided that the ALARA program needed to be upgraded and a significant improvement could be made if workers had a place they could visit that had samples of the latest technology and could talk to experienced personnel who have had success doing D and D work. Two senior health physics personnel who had many years experience in doing radiological work were chosen to obtain tools and equipment from vendors and find a location centrally located on the Hanford site. Vendors were asked to loan their latest tools and equipment for display. Most vendors responded and the Hanford ALARA Center of Technology opened on October 1, 1996. Today, the ALARA Center includes a classroom for conducting training and a mockup area with gloveboxes. Two large rooms have a containment tent, several glove bags, samples of fixatives/expandable foam, coating displays, protective clothing, heat stress technology, cutting tools, HEPA filtered vacuums, ventilation units, pumps, hydraulic wrenches, communications equipment, shears, nibblers, shrouded tooling, and several examples of innovative tools developed by the Hanford facilities. See Figures I and II. The ALARA Center staff routinely researches and tests new technology, sponsor vendor demonstrations, and redistribute tools, equipment and temporary shielding that may not be needed at one facility to another facility that needs it. The ALARA Center staff learns about new technology in several ways. This includes past radiological work experience, interaction with vendors, lessons learned, networking with other DOE sites, visits to the Hanford Technical Library, attendance at off-site conferences and ALARA Workshops. Personnel that contact the ALARA Center for assistance report positive results when they implement the tools, equipment and work practices recommended by the ALARA Center staff. This has translated to reduced exposure for workers and reduced the risk of contamination spread. For example: using a hydraulic shear on one job saved 16 Rem of exposure that would have been received if workers had used saws-all tools to cut piping in twenty-nine locations. Currently, the ALARA Center staff is emphasizing D and D techniques on size-reducing materials, decontamination techniques, use of remote tools/video equipment, capture ventilation, fixatives, using containments and how to find lessons learned. The ALARA Center staff issues a weekly report that discusses their interaction with the workforce and any new work practices, tools and equipment being used by the Hanford contractors. Distribution of this weekly report is to about 130 personnel on site and 90 personnel off site. This effectively spreads the word about ALARA throughout the DOE Complex. DOE EM-23, in conjunction with the D and D and Environmental Restoration work group of the Energy Facility Contractors Organization (EFCOG) established the Hanford ALARA Center as the D and D Hotline for companies who have questions about how D and D work is accomplished. The ALARA Center has become a resource to the nuclear industry and routinely helps contractors at other DOE Sites, power reactors, DOD sites, and sites in England, Europe and Indonesia. Other ALARA Centers are located at the Savannah River Site and Los Alamos National Lab.« less
Automatic welding of stainless steel tubing
NASA Technical Reports Server (NTRS)
Clautice, W. E.
1978-01-01
The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.
Automatic discovery of the communication network topology for building a supercomputer model
NASA Astrophysics Data System (ADS)
Sobolev, Sergey; Stefanov, Konstantin; Voevodin, Vadim
2016-10-01
The Research Computing Center of Lomonosov Moscow State University is developing the Octotron software suite for automatic monitoring and mitigation of emergency situations in supercomputers so as to maximize hardware reliability. The suite is based on a software model of the supercomputer. The model uses a graph to describe the computing system components and their interconnections. One of the most complex components of a supercomputer that needs to be included in the model is its communication network. This work describes the proposed approach for automatically discovering the Ethernet communication network topology in a supercomputer and its description in terms of the Octotron model. This suite automatically detects computing nodes and switches, collects information about them and identifies their interconnections. The application of this approach is demonstrated on the "Lomonosov" and "Lomonosov-2" supercomputers.
Maslow, Carey B; Friedman, Stephen M; Pillai, Parul S; Reibman, Joan; Berger, Kenneth I; Goldring, Roberta; Stellman, Steven D; Farfel, Mark
2012-06-01
We assessed associations between new-onset (post-September 11, 2001 [9/11]) lower respiratory symptoms reported on 2 surveys, administered 3 years apart, and acute and chronic 9/11-related exposures among New York City World Trade Center-area residents and workers enrolled in the World Trade Center Health Registry. World Trade Center-area residents and workers were categorized as case participants or control participants on the basis of lower respiratory symptoms reported in surveys administered 2 to 3 and 5 to 6 years after 9/11. We created composite exposure scales after principal components analyses of detailed exposure histories obtained during face-to-face interviews. We used multivariate logistic regression models to determine associations between lower respiratory symptoms and composite exposure scales. Both acute and chronic exposures to the events of 9/11 were independently associated, often in a dose-dependent manner, with lower respiratory symptoms among individuals who lived and worked in the area of the World Trade Center. Study findings argue for detailed assessments of exposure during and after events in the future from which potentially toxic materials may be released and for rapid interventions to minimize exposures and screen for potential adverse health effects.
Visual perception system and method for a humanoid robot
NASA Technical Reports Server (NTRS)
Chelian, Suhas E. (Inventor); Linn, Douglas Martin (Inventor); Wampler, II, Charles W. (Inventor); Bridgwater, Lyndon (Inventor); Wells, James W. (Inventor); Mc Kay, Neil David (Inventor)
2012-01-01
A robotic system includes a humanoid robot with robotic joints each moveable using an actuator(s), and a distributed controller for controlling the movement of each of the robotic joints. The controller includes a visual perception module (VPM) for visually identifying and tracking an object in the field of view of the robot under threshold lighting conditions. The VPM includes optical devices for collecting an image of the object, a positional extraction device, and a host machine having an algorithm for processing the image and positional information. The algorithm visually identifies and tracks the object, and automatically adapts an exposure time of the optical devices to prevent feature data loss of the image under the threshold lighting conditions. A method of identifying and tracking the object includes collecting the image, extracting positional information of the object, and automatically adapting the exposure time to thereby prevent feature data loss of the image.
AN OFF-CENTERED ACTIVE GALACTIC NUCLEUS IN NGC 3115
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menezes, R. B.; Steiner, J. E.; Ricci, T. V., E-mail: robertobm@astro.iag.usp.br
2014-11-20
NGC 3115 is an S0 galaxy that has always been considered to have a pure absorption-line spectrum. Some recent studies have detected a compact radio-emitting nucleus in this object, coinciding with the photometric center and with a candidate for the X-ray nucleus. This is evidence of the existence of a low-luminosity active galactic nucleus (AGN) in the galaxy, although no emission line has ever been observed. We report the detection of an emission-line spectrum of a type 1 AGN in NGC 3115, with an Hα luminosity of L {sub Hα} = (4.2 ± 0.4) × 10{sup 37} erg s{sup –1}. Our analysismore » revealed that this AGN is located at a projected distance of ∼0.''29 ± 0.''05 (corresponding to ∼14.3 ± 2.5 pc) from the stellar bulge center, which is coincident with the kinematic center of this object's stellar velocity map. The black hole corresponding to the observed off-centered AGN may form a binary system with a black hole located at the stellar bulge center. However, it is also possible that the displaced black hole is the merged remnant of the binary system coalescence, after the ''kick'' caused by the asymmetric emission of gravitational waves. We propose that certain features in the stellar velocity dispersion map are the result of perturbations caused by the off-centered AGN.« less
Diversity of culturable filamentous Ascomycetes in the eastern South Pacific Ocean off Chile.
Vera, Jeanett; Gutiérrez, Marcelo H; Palfner, Götz; Pantoja, Silvio
2017-08-01
Our study reports the diversity of culturable mycoplankton in the eastern South Pacific Ocean off Chile to contribute with novel knowledge on taxonomy of filamentous fungi isolated from distinct physicochemical and biological marine environments. We characterized spatial distribution of isolates, evaluated their viability and assessed the influence of organic substrate availability on fungal development. Thirty-nine Operational Taxonomic Units were identified from 99 fungal strains isolated from coastal and oceanic waters by using Automatic Barcode Gap Discovery. All Operational Taxonomic Units belonged to phylum Ascomycota and orders Eurotiales, Dothideales, Sordariales and Hypocreales, mainly Penicillium sp. (82%); 11 sequences did not match existing species in GenBank, suggesting occurrence of novel fungal taxa. Our results suggest that fungal communities in the South Pacific Ocean off Chile appear to thrive in a wide range of environmental conditions in the ocean and that substrate availability may be a factor influencing fungal viability in the ocean.
A New Global Regression Analysis Method for the Prediction of Wind Tunnel Model Weight Corrections
NASA Technical Reports Server (NTRS)
Ulbrich, Norbert Manfred; Bridge, Thomas M.; Amaya, Max A.
2014-01-01
A new global regression analysis method is discussed that predicts wind tunnel model weight corrections for strain-gage balance loads during a wind tunnel test. The method determines corrections by combining "wind-on" model attitude measurements with least squares estimates of the model weight and center of gravity coordinates that are obtained from "wind-off" data points. The method treats the least squares fit of the model weight separate from the fit of the center of gravity coordinates. Therefore, it performs two fits of "wind- off" data points and uses the least squares estimator of the model weight as an input for the fit of the center of gravity coordinates. Explicit equations for the least squares estimators of the weight and center of gravity coordinates are derived that simplify the implementation of the method in the data system software of a wind tunnel. In addition, recommendations for sets of "wind-off" data points are made that take typical model support system constraints into account. Explicit equations of the confidence intervals on the model weight and center of gravity coordinates and two different error analyses of the model weight prediction are also discussed in the appendices of the paper.
ERIC Educational Resources Information Center
Jacob, Carol J., Comp.
This conference proceedings of off-campus library services includes 37 papers covering the following topics: ensuring excellence in distance library services; DePaul University's research consultation service; using videos to promote library service; a virtual academic library project in England; student-centered library instruction off campus;…
Pediatric Minoxidil Exposures Reported to Texas Poison Centers.
Forrester, Mathias B
2018-06-01
It has been suggested that ingestion of even small amounts of minoxidil by young children may result in serious adverse effects. The intent of this study was to describe pediatric minoxidil exposures reported to a statewide poison center system. Cases were minoxidil exposures among patients 5 years or younger reported to Texas poison centers during 2000 to 2014. The distribution by various demographic and clinical factors was determined. Of 125 total cases, 58% were male and 78% aged 1 to 2 years. Ingestion alone was reported in 92% of the exposures. Ninety-eight percent of the exposures were unintentional, and 94% occurred at the patient's own residence. Sixty-two percent of the patients were managed on site. The outcome was not serious (no effect, minor effect, not followed [nontoxic], not followed [minimal effects]) in 88% of the exposures. The most common adverse effect was vomiting, reported in 8% of the exposures. The most common treatments were dilution/irrigation/wash (53%), activated charcoal (18%), food/snack (17%), and intravenous fluids (8%). Few pediatric minoxidil exposures were reported to Texas poison centers. Of these exposures, most involved ingestion, were unintentional, and involved patients who were male and aged 1 to 2 years. Although it has been suggested that pediatric minoxidil ingestions might result in serious adverse effects, this study suggests that most pediatric minoxidil exposures reported to poison centers are not likely to have serious outcomes and may be managed at home.
Virtual Reality as a Medium for Sensorimotor Adaptation Training and Spaceflight Countermeasures
NASA Technical Reports Server (NTRS)
Madansingh, S.; Bloomberg, J. J.
2015-01-01
With the upcoming shift to extra-long duration missions (1 year) aboard the ISS, sensorimotor adaptations during transitory periods in-and-out of microgravity are more important to understand and prepare for. Advances in virtual reality technology enables everyday adoption of these tools for entertainment and use in training. Experiencing virtual environments (VE) allows for the manipulation of visual flow to elicit automatic motor behavior and produce sensorimotor adaptation (SA). Recently, the ability to train individuals using repeatable and varied exposures to SA challenges has shown success by improving performance during exposure to a novel environment (Batson 2011). This capacity to 'learn to learn' is referred to as sensorimotor adaptive generalizability and, through the use of treadmill training, represents an untapped potential for individualized countermeasures. The goal of this study is to determine the feasibility of present head mounted displays (HMDs) to produce compelling visual flow information and the expected adaptations for use in future SA treadmill-based countermeasures. Participants experience infinite hallways providing congruent (baseline) or incongruent visual information (half or double speed) via HMD while walking on an instrumented treadmill at 1.1m/s. As gait performance approaches baseline levels, an adaptation time constant is derived to establish individual time-to-adapt (TTA). It is hypothesized that decreasing the TTA through SA treadmill training will facilitate sensorimotor adaptation during gravitational transitions. In this way, HMD technology represents a novel platform for SA training using off-the-shelf consumer products for greater training flexibility in astronaut and terrestrial applications alike.
Real-time robot deliberation by compilation and monitoring of anytime algorithms
NASA Technical Reports Server (NTRS)
Zilberstein, Shlomo
1994-01-01
Anytime algorithms are algorithms whose quality of results improves gradually as computation time increases. Certainty, accuracy, and specificity are metrics useful in anytime algorighm construction. It is widely accepted that a successful robotic system must trade off between decision quality and the computational resources used to produce it. Anytime algorithms were designed to offer such a trade off. A model of compilation and monitoring mechanisms needed to build robots that can efficiently control their deliberation time is presented. This approach simplifies the design and implementation of complex intelligent robots, mechanizes the composition and monitoring processes, and provides independent real time robotic systems that automatically adjust resource allocation to yield optimum performance.
Enzor, Laura A; Hankins, Cheryl; Vivian, Deborah N; Fisher, William S; Barron, Mace G
2018-02-01
Projected increases in ocean p CO 2 levels are anticipated to affect calcifying organisms more rapidly and to a greater extent than other marine organisms. The effects of ocean acidification (OA) have been documented in numerous species of corals in laboratory studies, largely tested using flow-through exposure systems. We developed a recirculating ocean acidification exposure system that allows precise p CO 2 control using a combination of off-gassing measures including aeration, water retention devices, venturi injectors, and CO 2 scrubbing. We evaluated the recirculating system performance in off-gassing effectiveness and maintenance of target p CO 2 levels over an 84-day experiment. The system was used to identify changes in calcification and tissue growth in response to elevated p CO 2 (1000 μatm) in three reef-building corals of the Caribbean: Pseudodiploria clivosa , Montastraea cavernosa , and Orbicella faveolata . All three species displayed an overall increase in net calcification over the 84-day exposure period regardless of p CO 2 level (control +0.28- 1.12 g, elevated p CO 2 +0.18- 1.16 g), and the system was effective at both off-gassing acidified water to ambient p CO 2 levels, and maintaining target elevated p CO 2 levels over the 3-month experiment.
1944-08-31
Towing installations on P-51 and P-61 airplanes for propeller off tests on the P-51. Rear view of P-61 in towing position preparing for take off at NACA Ames Research Center, Moffett Field, California
Water electrolysis system refurbishment and testing
NASA Technical Reports Server (NTRS)
Greenough, B. M.
1972-01-01
The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.
Singh, Sarabjeet; Petrovic, Dean; Jamnik, Ethen; Aran, Shima; Pourjabbar, Sarvenaz; Kave, Maggie L; Bradley, Stephen E; Choy, Garry; Kalra, Mannudeep K
2014-01-01
To evaluate the effect of localizing radiograph on computed tomography (CT) radiation dose associated with automatic exposure control with a human cadaver and patient study. Institutional review board approved the study with a waiver of informed consent. Two chest CT image series with fixed tube current and combined longitudinal-angular automatic exposure control (AEC) were acquired in a human cadaver (64-year-old man) after each of the 8 combinations of localizer radiographs (anteroposterior [AP], AP lateral, AP-posteroanterior [PA], lateral AP, lateral PA, PA, PA-AP, and PA lateral). Applied effective milliampere second, volume CT dose index (CTDIvol) and image noise were recorded for all 24-image series. Volume CT dose indexes were also recorded in 20 patients undergoing chest and abdominal CT after PA and PA-lateral radiographs with the use of AEC. Data were analyzed using analysis of variance and linear correlation tests. With AEC, the CTDIvol fluctuates with the number and projection of localizer radiographs (P < 0.0001). Lowest CTDIvol values are seen when 2 orthogonal localizer radiographs are acquired, whereas highest values are seen when single PA or AP-PA projection localizer radiographs are acquired for planning (P < 0.0001). In 20 patients, CT scanning with AEC after acquisition of 2 orthogonal projection localizer radiographs was associated with significant reduction in radiation dose compared to PA projection radiographs alone (P < 0.0001). When scanning with AEC, acquisition of 2 orthogonal localizer radiographs is associated with lower CTDIvol compared to a single localizer radiograph.
Wood, T J; Moore, C S; Stephens, A; Saunderson, J R; Beavis, A W
2015-09-01
Given the increasing use of computed tomography (CT) in the UK over the last 30 years, it is essential to ensure that all imaging protocols are optimised to keep radiation doses as low as reasonably practicable, consistent with the intended clinical task. However, the complexity of modern CT equipment can make this task difficult to achieve in practice. Recent results of local patient dose audits have shown discrepancies between two Philips CT scanners that use the DoseRight 2.0 automatic exposure control (AEC) system in the 'automatic' mode of operation. The use of this system can result in drifting dose and image quality performance over time as it is designed to evolve based on operator technique. The purpose of this study was to develop a practical technique for configuring examination protocols on four CT scanners that use the DoseRight 2.0 AEC system in the 'manual' mode of operation. This method used a uniform phantom to generate reference images which form the basis for how the AEC system calculates exposure factors for any given patient. The results of this study have demonstrated excellent agreement in the configuration of the CT scanners in terms of average patient dose and image quality when using this technique. This work highlights the importance of CT protocol harmonisation in a modern Radiology department to ensure both consistent image quality and radiation dose. Following this study, the average radiation dose for a range of CT examinations has been reduced without any negative impact on clinical image quality.
Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H
2015-01-01
To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.
Chomiak, Taylor; Watts, Alexander; Meyer, Nicole; Pereira, Fernando V; Hu, Bin
2017-02-01
Deficits in motor movement automaticity in Parkinson's disease (PD), especially during multitasking, are early and consistent hallmarks of cognitive function decline, which increases fall risk and reduces quality of life. This study aimed to test the feasibility and potential efficacy of a wearable sensor-enabled technological platform designed for an in-home music-contingent stepping-in-place (SIP) training program to improve step automaticity during dual-tasking (DT). This was a 4-week prospective intervention pilot study. The intervention uses a sensor system and algorithm that runs off the iPod Touch which calculates step height (SH) in real-time. These measurements were then used to trigger auditory (treatment group, music; control group, radio podcast) playback in real-time through wireless headphones upon maintenance of repeated large amplitude stepping. With small steps or shuffling, auditory playback stops, thus allowing participants to use anticipatory motor control to regain positive feedback. Eleven participants were recruited from an ongoing trial (Trial Number: ISRCTN06023392). Fear of falling (FES-I), general cognitive functioning (MoCA), self-reported freezing of gait (FOG-Q), and DT step automaticity were evaluated. While we found no significant effect of training on FES-I, MoCA, or FOG-Q, we did observe a significant group (music vs podcast) by training interaction in DT step automaticity (P<0.01). Wearable device technology can be used to enable musically-contingent SIP training to increase motor automaticity for people living with PD. The training approach described here can be implemented at home to meet the growing demand for self-management of symptoms by patients.
Obesity markers associated to albuminuria in a primary care center in Lima, Perú.
Quintanilla, Alberto E; Taype-Rondan, Álvaro; Lazo-Porras, María; Herrera-Añazco, Percy
To evaluate the association between three obesity markers, body mass index (BMI), abdominal circumference (AC), waist to height ratio (WHtR), and albuminuria in adults seen in a primary health care center specialized in chronic diseases in Lima, Perú. A cross-sectional, descriptive, retrospective study in adults who attended a primary health care center specialized in chronic diseases in 2011. Patients were divided into four categories: healthy subjects and patients with high blood pressure, with type 2 diabetes mellitus (T2DM), and with both diseases (HBP+T2DM). The main outcome was presence of albuminuria, defined as urine albumin levels higher than 30mg/day. Exposure variables included the following obesity markers: body mass index (BMI), waist-to-height ratio (WHtR), and abdominal circumference (AC). Other covariates considered included sex and age. Crude and adjusted Poisson regressions were performed to estimate prevalence ratios (PRs) and their respective 95% confidence intervals (95% CIs). Areas under the curve were calculated for each indicator, stratified by sex. Data from 1,214 patients, 41% of them male, were analyzed, and albuminuria was found in 14.2%. Albuminuria was found to be associated to AC and WHtR, but not to BMI. All three parameters assessed had similar areas under the curve. The optimum cut-off points found for BMI and AC in females were higher than conventional (32.7kg/m 2 and 93cm respectively), while the values in males were lower than conventional (27.9kg/m 2 and 100cm respectively). For WHtR, however, the optimum cut-off point was higher in both sexes. The higher index in females was for BMI, followed by AC and WHtR. In males, the higher index was for WHtR, followed by AC and BMI. AC and WHtR were found to be directly associated to albuminuria, while BMI was not associated to albuminuria. Areas under the curve were similar for all three markers. The optimum cut-off points for BMI and AC were higher than the conventional ones in females and lower in males. Copyright © 2017 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.
Automatic centring and bonding of lenses
NASA Astrophysics Data System (ADS)
Krey, Stefan; Heinisch, J.; Dumitrescu, E.
2007-05-01
We present an automatic bonding station which is able to center and bond individual lenses or doublets to a barrel with sub micron centring accuracy. The complete manufacturing cycle includes the glue dispensing and UV curing. During the process the state of centring is continuously controlled by the vision software, and the final result is recorded to a file for process statistics. Simple pass or fail results are displayed to the operator at the end of the process.
Research on large spatial coordinate automatic measuring system based on multilateral method
NASA Astrophysics Data System (ADS)
Miao, Dongjing; Li, Jianshuan; Li, Lianfu; Jiang, Yuanlin; Kang, Yao; He, Mingzhao; Deng, Xiangrui
2015-10-01
To measure the spatial coordinate accurately and efficiently in large size range, a manipulator automatic measurement system which based on multilateral method is developed. This system is divided into two parts: The coordinate measurement subsystem is consists of four laser tracers, and the trajectory generation subsystem is composed by a manipulator and a rail. To ensure that there is no laser beam break during the measurement process, an optimization function is constructed by using the vectors between the laser tracers measuring center and the cat's eye reflector measuring center, then an orientation automatically adjust algorithm for the reflector is proposed, with this algorithm, the laser tracers are always been able to track the reflector during the entire measurement process. Finally, the proposed algorithm is validated by taking the calibration of laser tracker for instance: the actual experiment is conducted in 5m × 3m × 3.2m range, the algorithm is used to plan the orientations of the reflector corresponding to the given 24 points automatically. After improving orientations of some minority points with adverse angles, the final results are used to control the manipulator's motion. During the actual movement, there are no beam break occurs. The result shows that the proposed algorithm help the developed system to measure the spatial coordinates over a large range with efficiency.
Right pleuropericardial release: a useful technique in off-pump coronary surgery.
Velissaris, Theodore; Stuklis, Robert G; Hett, David A; Ohri, Sunil K
2003-06-01
We describe the use of right pleurotomy combined with right pericardial release during off-pump coronary surgery. The maneuver releases the compression exerted on the right cardiac chambers during cardiac verticalization and improves hemodynamic stability during exposure of the posterior or lateral coronary vessels.
Colorimetric calibration of wound photography with off-the-shelf devices
NASA Astrophysics Data System (ADS)
Bala, Subhankar; Sirazitdinova, Ekaterina; Deserno, Thomas M.
2017-03-01
Digital cameras are often used in recent days for photographic documentation in medical sciences. However, color reproducibility of same objects suffers from different illuminations and lighting conditions. This variation in color representation is problematic when the images are used for segmentation and measurements based on color thresholds. In this paper, motivated by photographic follow-up of chronic wounds, we assess the impact of (i) gamma correction, (ii) white balancing, (iii) background unification, and (iv) reference card-based color correction. Automatic gamma correction and white balancing are applied to support the calibration procedure, where gamma correction is a nonlinear color transform. For unevenly illuminated images, non- uniform illumination correction is applied. In the last step, we apply colorimetric calibration using a reference color card of 24 patches with known colors. A lattice detection algorithm is used for locating the card. The least squares algorithm is applied for affine color calibration in the RGB model. We have tested the algorithm on images with seven different types of illumination: with and without flash using three different off-the-shelf cameras including smartphones. We analyzed the spread of resulting color value of selected color patch before and after applying the calibration. Additionally, we checked the individual contribution of different steps of the whole calibration process. Using all steps, we were able to achieve a maximum of 81% reduction in standard deviation of color patch values in resulting images comparing to the original images. That supports manual as well as automatic quantitative wound assessments with off-the-shelf devices.
Sannino, Giovanna; De Falco, Ivanoe; De Pietro, Giuseppe
2014-06-01
Real-time Obstructive Sleep Apnea (OSA) episode detection and monitoring are important for society in terms of an improvement in the health of the general population and of a reduction in mortality and healthcare costs. Currently, to diagnose OSA patients undergo PolySomnoGraphy (PSG), a complicated and invasive test to be performed in a specialized center involving many sensors and wires. Accordingly, each patient is required to stay in the same position throughout the duration of one night, thus restricting their movements. This paper proposes an easy, cheap, and portable approach for the monitoring of patients with OSA, which collects single-channel ElectroCardioGram (ECG) data only. It is easy to perform from the patient's point of view because only one wearable sensor is required, so the patient is not restricted to keeping the same position all night long, and the detection and monitoring can be carried out in any place through the use of a mobile device. Our approach is based on the automatic extraction, from a database containing information about the monitored patient, of explicit knowledge in the form of a set of IF…THEN rules containing typical parameters derived from Heart Rate Variability (HRV) analysis. The extraction is carried out off-line by means of a Differential Evolution algorithm. This set of rules can then be exploited in the real-time mobile monitoring system developed at our Laboratory: the ECG data is gathered by a wearable sensor and sent to a mobile device, where it is processed in real time. Subsequently, HRV-related parameters are computed from this data, and, if their values activate some of the rules describing the occurrence of OSA, an alarm is automatically produced. This approach has been tested on a well-known literature database of OSA patients. The numerical results show its effectiveness in terms of accuracy, sensitivity, and specificity, and the achieved sets of rules evidence the user-friendliness of the approach. Furthermore, the method is compared against other well known classifiers, and its discrimination ability is shown to be higher. Copyright © 2014 Elsevier Inc. All rights reserved.
Faure, Elodie; Danjou, Aurélie M N; Clavel-Chapelon, Françoise; Boutron-Ruault, Marie-Christine; Dossus, Laure; Fervers, Béatrice
2017-02-24
Environmental exposure assessment based on Geographic Information Systems (GIS) and study participants' residential proximity to environmental exposure sources relies on the positional accuracy of subjects' residences to avoid misclassification bias. Our study compared the positional accuracy of two automatic geocoding methods to a manual reference method. We geocoded 4,247 address records representing the residential history (1990-2008) of 1,685 women from the French national E3N cohort living in the Rhône-Alpes region. We compared two automatic geocoding methods, a free-online geocoding service (method A) and an in-house geocoder (method B), to a reference layer created by manually relocating addresses from method A (method R). For each automatic geocoding method, positional accuracy levels were compared according to the urban/rural status of addresses and time-periods (1990-2000, 2001-2008), using Chi Square tests. Kappa statistics were performed to assess agreement of positional accuracy of both methods A and B with the reference method, overall, by time-periods and by urban/rural status of addresses. Respectively 81.4% and 84.4% of addresses were geocoded to the exact address (65.1% and 61.4%) or to the street segment (16.3% and 23.0%) with methods A and B. In the reference layer, geocoding accuracy was higher in urban areas compared to rural areas (74.4% vs. 10.5% addresses geocoded to the address or interpolated address level, p < 0.0001); no difference was observed according to the period of residence. Compared to the reference method, median positional errors were 0.0 m (IQR = 0.0-37.2 m) and 26.5 m (8.0-134.8 m), with positional errors <100 m for 82.5% and 71.3% of addresses, for method A and method B respectively. Positional agreement of method A and method B with method R was 'substantial' for both methods, with kappa coefficients of 0.60 and 0.61 for methods A and B, respectively. Our study demonstrates the feasibility of geocoding residential addresses in epidemiological studies not initially recorded for environmental exposure assessment, for both recent addresses and residence locations more than 20 years ago. Accuracy of the two automatic geocoding methods was comparable. The in-house method (B) allowed a better control of the geocoding process and was less time consuming.
The brain is the control center of the body. It controls thoughts, memory, speech, and movement. It regulates the function of many organs. When the brain is healthy, it works quickly and automatically. However, ...
Alkyl Glucosides in Contact Dermatitis.
Loranger, Camille; Alfalah, Maisa; Ferrier Le Bouedec, Marie-Christine; Sasseville, Denis
Ecologically sound because they are synthesized from natural and renewable sources, the mild surfactants alkyl glucosides are being rediscovered by the cosmetic industry. They are currently found in rinse-off products such as shampoos, liquid cleansers, and shower gels, but also in leave-on products that include moisturizers, deodorants, and sunscreens. During the past 15 years, numerous cases of allergic contact dermatitis have been published, mostly to lauryl and decyl glucosides, and these compounds are considered emergent allergens. Interestingly, the sunscreen Tinosorb M contains decyl glucoside as a hidden allergen, and most cases of allergic contact dermatitis reported to this sunscreen ingredient are probably due to sensitization to decyl glucoside. This article will review the chemistry of alkyl glucosides, their sources of exposure, as well as their cutaneous adverse effects reported in the literature and encountered in various patch testing centers.
Electronic Cigarette Exposure: Calls to Wisconsin Poison Control Centers, 2010–2015.
Weiss, Debora; Tomasallo, Carrie D; Meiman, Jon G; Creswell, Paul D; Melstrom, Paul C; Gummin, David D; Patel, Disa J; Michaud, Nancy T; Sebero, Heather A; Anderson, Henry A
2016-12-01
E-cigarettes are battery-powered devices that deliver nicotine and flavorings by aerosol and have been marketed in the United States since 2007. Because e-cigarettes have increased in popularity, toxicity potential from device misuse and malfunction also has increased. National data indicate that during 2010–2014, exposure calls to US poison control centers increased only 0.3% for conventional cigarette exposures, whereas calls increased 41.7% for e-cigarette exposures. We characterized cigarette and e-cigarette exposure calls to the Wisconsin Poison Center January 1, 2010 through October 10, 2015. We compared cigarette and e-cigarette exposure calls by exposure year, demographic characteristics, caller site, exposure site, exposure route, exposure reason, medical outcome, management site, and level of care at a health care facility. During January 2010 to October 2015, a total of 98 e-cigarette exposure calls were reported, and annual exposure calls increased approximately 17-fold, from 2 to 35. During the same period, 671 single-exposure cigarette calls with stable annual call volumes were reported. E-cigarette exposure calls were associated with children aged ≤5 years (57/98, 58.2%) and adults aged ≥20 years (30/98, 30.6%). Cigarette exposure calls predominated among children aged ≤5 years (643/671, 95.8%). The frequency of e-cigarette exposure calls to the Wisconsin Poison Center has increased and is highest among children aged ≤5 years and adults. Strategies are warranted to prevent future poisonings from these devices, including nicotine warning labels and public advisories to keep e-cigarettes away from children.
Alternative Fuels Data Center: Maps and Data
control systems and appliances with off-board sources of electricity, thereby reducing the need to idle trucks to power climate control systems and appliances with off-board sources of electricity, thereby
1944-08-31
Towing installations on P-51 and P-61 airplanes for propeller off tests on the P-51 Front view of P-51 & P-61 in towing position preparing for take off at NACA Ames Research Center, Moffett Field, California
1944-08-31
Towing installations on P-51 and P-61 airplanes for propeller off tests on the P-51 Front view of P-51 & P-61 in towing position preparing for take off at NACA Ames Research Center, Moffett Field, California
1944-08-31
Towing installations on P-51 airplane for propeller off tests on the P-51 Front view of P-51 in towing position with P-61A preparing for take off at NACA Ames Research Center, Moffett Field, California
2003-03-07
File name :DSC_0749.JPG File size :1.1MB(1174690Bytes) Date taken :2003/03/07 13:51:29 Image size :2000 x 1312 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D1H Quality mode :FINE Metering mode :Matrix Exposure mode :Shutter priority Speed light :No Focal length :20 mm Shutter speed :1/500second Aperture :F11.0 Exposure compensation :0 EV White Balance :Auto Lens :20 mm F 2.8 Flash sync mode :N/A Exposure difference :0.0 EV Flexible program :No Sensitivity :ISO200 Sharpening :Normal Image Type :Color Color Mode :Mode II(Adobe RGB) Hue adjustment :3 Saturation Control :N/A Tone compensation :Normal Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
2002-02-19
File name :DSC_0028.JPG File size :2.8MB(2950833Bytes) Date taken :2002/02/19 09:49:01 Image size :3008 x 2000 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D100 Quality mode :N/A Metering mode :Matrix Exposure mode :Shutter priority Speed light :Yes Focal length :24 mm Shutter speed :1/60second Aperture :F3.5 Exposure compensation :0 EV White Balance :N/A Lens :N/A Flash sync mode :N/A Exposure difference :N/A Flexible program :N/A Sensitivity :N/A Sharpening :N/A Image Type :Color Color Mode :N/A Hue adjustment :N/A Saturation Control :N/A Tone compensation :N/A Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
2002-02-24
File name :DSC_0047.JPG File size :2.8MB(2931574Bytes) Date taken :2002/02/24 10:06:57 Image size :3008 x 2000 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D100 Quality mode :N/A Metering mode :Matrix Exposure mode :Shutter priority Speed light :Yes Focal length :24 mm Shutter speed :1/180second Aperture :F20.0 Exposure compensation :+0.3 EV White Balance :N/A Lens :N/A Flash sync mode :N/A Exposure difference :N/A Flexible program :N/A Sensitivity :N/A Sharpening :N/A Image Type :Color Color Mode :N/A Hue adjustment :N/A Saturation Control :N/A Tone compensation :N/A Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A
Night work, light exposure and melatonin on work days and days off.
Daugaard, Stine; Garde, Anne Helene; Bonde, Jens Peter Ellekilde; Christoffersen, Jens; Hansen, Äse Marie; Markvart, Jakob; Schlünssen, Vivi; Skene, Debra J; Vistisen, Helene Tilma; Kolstad, Henrik A
2017-01-01
We aimed to examine the effects of night work on salivary melatonin concentration during and subsequent to night work and the mediating role of light. We included 254 day workers and 87 night workers who were followed during 322 work days and 301 days off work. Each day was defined as the 24 hour period starting from the beginning of a night shift or from waking in the mornings with day work and days off. Light levels were recorded and synchronized with diary information (start and end of sleep and work). On average, participants provided four saliva samples per day, and these were analyzed for melatonin concentration by liquid chromatography tandem mass spectrometry (LC-MS/MS). Differences between day and night workers on work days and days off were assessed with multilevel regression models with melatonin concentration as the primary outcome. All models were stratified or adjusted by time of day. For light exposure, we estimated the total, direct and indirect effects of night work on melatonin concentrations obtaining 95% confidence intervals through bootstrapping. On work days, night workers showed 15% lower salivary melatonin concentrations compared with day workers (-15.0%; 95% CI: -31.4%; 5.2%). During the night, light exposure mediated a melatonin suppression of approximately 6% (-5.9%, 95% CI: -10.2%; -1.5%). No mediating effect of light was seen during the day time. On days off, we observed no difference in melatonin concentrations between day and night workers. These findings are in accordance with a transient and partly light-mediated effect of night work on melatonin production.
Chung, Yi-Chieh; Cannella-Malone, Helen I
2010-11-01
This study examined the effects of presession exposure to attention, response blocking, attention with response blocking, and noninteraction conditions on subsequent engagement in automatically maintained challenging behavior and correct responding in four individuals with significant intellectual disabilities. Following a functional analysis, the effects of the four presession conditions were examined using multielement designs. Results varied across the 4 participants (e.g., presession noninteraction acted as an abolishing operation for 2 participants, but as an establishing operation for the other 2 participants). As such, both the results replicated and contradicted previous research examining the effects of motivating operations on automatically maintained challenging behavior. Although the results varied across participants, at least one condition resulting in a decrease in challenging behavior and an increase in correct responding were identified for each participant. These findings suggested that presession manipulations resulted in decreases in subsequent automatically maintained challenging behavior and simultaneous increases in correct responding might need to be individually identified when the maintaining contingencies cannot be identified.
FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector.
Schäfer, Dirk; Grass, Michael; van de Haar, Peter
2011-07-01
Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.
Facilities | Transportation Research | NREL
detailed chemical characterization, performance property measurements, and stability research. Photo of Technology Evaluation Center This off-network data center provides secure management, storage, and processing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-10
The Skinner Landfill is a former landfill in West Chester, Butler County, Ohio. On-site soil, groundwater, and surface water are contaminated with volatile organic compounds (VOCs), semivolatile organic compounds, pesticides, arsenic, and lead. Off-site contamination is minimal. The Skinner Landfill site poses an indeterminate public health hazard. Potential exposure pathways of concern are the ingestion of surface soils containing lead and the ingestion of VOCs in groundwater. Groundwater is a potential exposure pathway because there are uncertainties concerning the potential for contaminated groundwater to move off site.
Beauchamp, Gillian A; McKeown, Nathanael J; Rodriguez, Sergio; Spyker, Daniel A
2016-03-01
The Centers for Disease Control (CDC) monitors influenza like illness (ILI) and the National Poison Data System (NPDS) warehouses call data uploaded by US poison centers regarding reported exposures to medication. We examined the relationship between calls to poison centers regarding reported exposures to medications commonly used to treat ILI and weekly reports of ILI. The CDC reports ILI, by age group, for each of 10 Health and Human Services (HHS) regions. We examined NPDS summary data from calls reported to poison centers regarding reported exposures to acetaminophen, cough/cold medications, and promethazine, for the same weeks, age groups, and HHS regions for influenza seasons 2000-2013. ILI and NPDS exposures were examined using graphical plots, descriptive statistics, stepwise regression analysis, and Geographic Information Systems (GIS). About 5,101,841 influenza-like illness cases were reported to the CDC, and 2,122,940 calls regarding reported exposures to medications commonly used to treat ILI, were reported by poison centers to the NPDS over the 13 flu seasons. Analysis of stepwise models of the linear untransformed data involving 24 NPDS data groups and for 60 ILI measures, over the 13 influenza seasons, demonstrated that reported exposures to medications used to treat ILI correlated with reported cases of ILI with a median R(2 )=( )0.489 (min R(2 )=( )0.248, max R(2 )=( )0.717), with mean ± SD of R(2 )=( )0.494 ± 0.121. Median number of parameters used (degrees of freedom - 1) was 7. NPDS data regarding poison center calls for selected ILI medication exposures were highly correlated with CDC ILI data. Since NPDS data are available in real time, it provides complimentary ILI monitoring. This approach may provide public health value in predicting other illnesses which are not currently as thoroughly monitored.
Identifying energy constraints to parasite resistance.
Allen, D E; Little, T J
2011-01-01
Life-history theory suggests that energetically expensive traits may trade off against each other, resulting in costs associated with the development or maintenance of a particular phenotype. The deployment of resistance mechanisms during parasite exposure is one such trait, and thus their potential benefit in fighting off parasites may be offset by costs to other fitness-related traits. In this study, we used trade-off theory as a basis to test whether stimulating an increased development rate in juvenile Daphnia would reveal energetic constraints to its ability to resist infection upon subsequent exposure to the castrating parasite, Pasteuria ramosa. We show that the presumably energetically expensive process of increased development rate does result in more infected hosts, suggesting that parasite resistance requires the allocation of resources from a limited source, and thus has the potential to be costly.
Teaching torque with 5E learning strategy: an off-center disk case
NASA Astrophysics Data System (ADS)
Balta, Nuri
2018-01-01
In this paper, five simple demonstrations with an off-center disk that can be easily constructed and demonstrated in science class are described along with the 5E learning strategy. These demonstrations can be used to help students develop an understanding of the relationship between the centre of mass and torque. These STEM activities are appropriate for high school or first-year college physics, and are expected to engage students during physics courses.
The Centaur Director kicks off Environment and Energy Awareness Week
NASA Technical Reports Server (NTRS)
1999-01-01
The opening of Environmental and Energy Awareness Week at the Kennedy Space Center Visitor Complex kicked off with a visit by Center Director Roy Bridges and the Awareness team, who presented him with a t-shirt. Exhibits and displays by KSC and 45th Space Wing organizations detail accomplishments in minimizing environmental impacts and conserving resources. They are on view April 19 - 22 at various sites at KSC, Cape Canaveral Air Station and Patrick Air Force Base.
Photosynthetic Photovoltaic Cells
2007-06-21
OFF (T). B. SPR detection of the binding of Ni2+, RC, and cytochrome to NTA surface. The arrows indicate the periods of time ON (t) and OFF (1) when...photosynthesis. Structure and spectroscopy of reaction centers of purple bacteria . Physics Reports-Review Section of Physics Letters, 1997. 287(1-2): p. 2-247. 7...photosynthetic bacteria reaction centers. Journal of Photochemistry and Photobiology a-Chemistry, 1997. 111(1-3): p. 111-138. 27. Beratan, D.N., J.N. Betts, and
Image acquisition system for traffic monitoring applications
NASA Astrophysics Data System (ADS)
Auty, Glen; Corke, Peter I.; Dunn, Paul; Jensen, Murray; Macintyre, Ian B.; Mills, Dennis C.; Nguyen, Hao; Simons, Ben
1995-03-01
An imaging system for monitoring traffic on multilane highways is discussed. The system, named Safe-T-Cam, is capable of operating 24 hours per day in all but extreme weather conditions and can capture still images of vehicles traveling up to 160 km/hr. Systems operating at different remote locations are networked to allow transmission of images and data to a control center. A remote site facility comprises a vehicle detection and classification module (VCDM), an image acquisition module (IAM) and a license plate recognition module (LPRM). The remote site is connected to the central site by an ISDN communications network. The remote site system is discussed in this paper. The VCDM consists of a video camera, a specialized exposure control unit to maintain consistent image characteristics, and a 'real-time' image processing system that processes 50 images per second. The VCDM can detect and classify vehicles (e.g. cars from trucks). The vehicle class is used to determine what data should be recorded. The VCDM uses a vehicle tracking technique to allow optimum triggering of the high resolution camera of the IAM. The IAM camera combines the features necessary to operate consistently in the harsh environment encountered when imaging a vehicle 'head-on' in both day and night conditions. The image clarity obtained is ideally suited for automatic location and recognition of the vehicle license plate. This paper discusses the camera geometry, sensor characteristics and the image processing methods which permit consistent vehicle segmentation from a cluttered background allowing object oriented pattern recognition to be used for vehicle classification. The image capture of high resolution images and the image characteristics required for the LPRMs automatic reading of vehicle license plates, is also discussed. The results of field tests presented demonstrate that the vision based Safe-T-Cam system, currently installed on open highways, is capable of producing automatic classification of vehicle class and recording of vehicle numberplates with a success rate around 90 percent in a period of 24 hours.
Solar exposure of sunglasses: aging test display
NASA Astrophysics Data System (ADS)
Gomes, L. M.; Masili, M.; Momesso, G. A.; Silva, F. M.; Ventura, L.
2018-02-01
In previous studies conducted in our lab, we have been investigating the aging effects on sunglasses. Some preliminary results have been indicating changes on the UV protection on the lenses. Therefore, besides irradiating the samples with a proper sun simulator, we have also been concerned on exposing the sunglasses to natural sun for further investigation and comparisons. Thus, this project aims expose the lenses for 24 months using an automatic solar exposition station, which consists of a series of 5 panels, housing 60 lenses arranged in the vertical position to the ground, which will be irradiated by the sun from sunrise until sunset. A box structure moves along a rail, driven by a motor and then the lenses are exposed. Humidity, rain, temperature, dust and UV index sensors, as well as a video camera are part of the system. The exposure time and UV index will be recorded and automatic opening or closing the box system may also be controlled by a PC using a webserver. The system was tested in working conditions, i.e. exposed to the weather and being automatically controlled, for five months to certifying that the samples could be exposed without being damaged. The next step of the research is to start the exposition cycles and to measure the expected transmittance variations after each cycle.
Neophytou, Andreas M.; Noth, Elizabeth M.; Liu, Sa; Costello, Sadie; Hammond, S. Katharine; Cullen, Mark R.; Eisen, Ellen A.
2016-01-01
Ischemic heart disease (IHD) has been linked to exposures to airborne particles with an aerodynamic diameter <2.5 μm (PM2.5) in the ambient environment and in occupational settings. Routine industrial exposure monitoring, however, has traditionally focused on total particulate matter (TPM). To assess potential benefits of PM2.5 monitoring, we compared the exposure-response relationships between both PM2.5 and TPM and incidence of IHD in a cohort of active aluminum industry workers. To account for the presence of time varying confounding by health status we applied marginal structural Cox models in a cohort followed with medical claims data for IHD incidence from 1998 to 2012. Analyses were stratified by work process into smelters (n = 6,579) and fabrication (n = 7,432). Binary exposure was defined by the 10th-percentile cut-off from the respective TPM and PM2.5 exposure distributions for each work process. Hazard Ratios (HR) comparing always exposed above the exposure cut-off to always exposed below the cut-off were higher for PM2.5, with HRs of 1.70 (95% confidence interval (CI): 1.11–2.60) and 1.48 (95% CI: 1.02–2.13) in smelters and fabrication, respectively. For TPM, the HRs were 1.25 (95% CI: 0.89–1.77) and 1.25 (95% CI: 0.88–1.77) for smelters and fabrication respectively. Although TPM and PM2.5 were highly correlated in this work environment, results indicate that, consistent with biologic plausibility, PM2.5 is a stronger predictor of IHD risk than TPM. Cardiovascular risk management in the aluminum industry, and other similar work environments, could be better guided by exposure surveillance programs monitoring PM2.5. PMID:27249060
Partanen, Eino; Leminen, Alina; de Paoli, Stine; Bundgaard, Anette; Kingo, Osman Skjold; Krøjgaard, Peter; Shtyrov, Yury
2017-07-15
Children learn new words and word forms with ease, often acquiring a new word after very few repetitions. Recent neurophysiological research on word form acquisition in adults indicates that novel words can be acquired within minutes of repetitive exposure to them, regardless of the individual's focused attention on the speech input. Although it is well-known that children surpass adults in language acquisition, the developmental aspects of such rapid and automatic neural acquisition mechanisms remain unexplored. To address this open question, we used magnetoencephalography (MEG) to scrutinise brain dynamics elicited by spoken words and word-like sounds in healthy monolingual (Danish) children throughout a 20-min repetitive passive exposure session. We found rapid neural dynamics manifested as an enhancement of early (~100ms) brain activity over the short exposure session, with distinct spatiotemporal patterns for different novel sounds. For novel Danish word forms, signs of such enhancement were seen in the left temporal regions only, suggesting reliance on pre-existing language circuits for acquisition of novel word forms with native phonology. In contrast, exposure both to novel word forms with non-native phonology and to novel non-speech sounds led to activity enhancement in both left and right hemispheres, suggesting that more wide-spread cortical networks contribute to the build-up of memory traces for non-native and non-speech sounds. Similar studies in adults have previously reported more sluggish (~15-25min, as opposed to 4min in the present study) or non-existent neural dynamics for non-native sound acquisition, which might be indicative of a higher degree of plasticity in the children's brain. Overall, the results indicate a rapid and highly plastic mechanism for a dynamic build-up of memory traces for novel acoustic information in the children's brain that operates automatically and recruits bilateral temporal cortical circuits. Copyright © 2017 Elsevier Inc. All rights reserved.
A voice-input voice-output communication aid for people with severe speech impairment.
Hawley, Mark S; Cunningham, Stuart P; Green, Phil D; Enderby, Pam; Palmer, Rebecca; Sehgal, Siddharth; O'Neill, Peter
2013-01-01
A new form of augmentative and alternative communication (AAC) device for people with severe speech impairment-the voice-input voice-output communication aid (VIVOCA)-is described. The VIVOCA recognizes the disordered speech of the user and builds messages, which are converted into synthetic speech. System development was carried out employing user-centered design and development methods, which identified and refined key requirements for the device. A novel methodology for building small vocabulary, speaker-dependent automatic speech recognizers with reduced amounts of training data, was applied. Experiments showed that this method is successful in generating good recognition performance (mean accuracy 96%) on highly disordered speech, even when recognition perplexity is increased. The selected message-building technique traded off various factors including speed of message construction and range of available message outputs. The VIVOCA was evaluated in a field trial by individuals with moderate to severe dysarthria and confirmed that they can make use of the device to produce intelligible speech output from disordered speech input. The trial highlighted some issues which limit the performance and usability of the device when applied in real usage situations, with mean recognition accuracy of 67% in these circumstances. These limitations will be addressed in future work.
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
Schuurmann, R C L; Kuster, L; Slump, C H; Vahl, A; van den Heuvel, D A F; Ouriel, K; de Vries, J-P P M
2016-02-01
Supra- and infrarenal aortic neck angulation have been associated with complications after endovascular aortic aneurysm repair. However, a uniform angulation measurement method is lacking and the concept of angulation suggests a triangular oversimplification of the aortic anatomy. (Semi-)automated calculation of curvature along the center luminal line describes the actual trajectory of the aorta. This study proposes a methodology for calculating aortic (neck) curvature and suggests an additional method based on available tools in current workstations: curvature by digital calipers (CDC). Proprietary custom software was developed for automatic calculation of the severity and location of the largest supra- and infrarenal curvature over the center luminal line. Twenty-four patients with severe supra- or infrarenal angulations (≥45°) and 11 patients with small to moderate angulations (<45°) were included. Both CDC and angulation were measured by two independent observers on the pre- and postoperative computed tomographic angiography scans. The relationships between actual curvature and CDC and angulation were visualized and tested with Pearson's correlation coefficient. The CDC was also fully automatically calculated with proprietary custom software. The difference between manual and automatic determination of CDC was tested with a paired Student t test. A p-value was considered significant when two-tailed α < .05. The correlation between actual curvature and manual CDC is strong (.586-.962) and even stronger for automatic CDC (.865-.961). The correlation between actual curvature and angulation is much lower (.410-.737). Flow direction angulation values overestimate CDC measurements by 60%, with larger variance. No significant difference was found in automatically calculated CDC values and manually measured CDC values. Curvature calculation of the aortic neck improves determination of the true aortic trajectory. Automatic calculation of the actual curvature is preferable, but measurement or calculation of the curvature by digital calipers is a valid alternative if actual curvature is not at hand. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Effects of cell phone radiofrequency signal exposure on brain glucose metabolism.
Volkow, Nora D; Tomasi, Dardo; Wang, Gene-Jack; Vaska, Paul; Fowler, Joanna S; Telang, Frank; Alexoff, Dave; Logan, Jean; Wong, Christopher
2011-02-23
The dramatic increase in use of cellular telephones has generated concern about possible negative effects of radiofrequency signals delivered to the brain. However, whether acute cell phone exposure affects the human brain is unclear. To evaluate if acute cell phone exposure affects brain glucose metabolism, a marker of brain activity. Randomized crossover study conducted between January 1 and December 31, 2009, at a single US laboratory among 47 healthy participants recruited from the community. Cell phones were placed on the left and right ears and positron emission tomography with ((18)F)fluorodeoxyglucose injection was used to measure brain glucose metabolism twice, once with the right cell phone activated (sound muted) for 50 minutes ("on" condition) and once with both cell phones deactivated ("off" condition). Statistical parametric mapping was used to compare metabolism between on and off conditions using paired t tests, and Pearson linear correlations were used to verify the association of metabolism and estimated amplitude of radiofrequency-modulated electromagnetic waves emitted by the cell phone. Clusters with at least 1000 voxels (volume >8 cm(3)) and P < .05 (corrected for multiple comparisons) were considered significant. Brain glucose metabolism computed as absolute metabolism (μmol/100 g per minute) and as normalized metabolism (region/whole brain). Whole-brain metabolism did not differ between on and off conditions. In contrast, metabolism in the region closest to the antenna (orbitofrontal cortex and temporal pole) was significantly higher for on than off conditions (35.7 vs 33.3 μmol/100 g per minute; mean difference, 2.4 [95% confidence interval, 0.67-4.2]; P = .004). The increases were significantly correlated with the estimated electromagnetic field amplitudes both for absolute metabolism (R = 0.95, P < .001) and normalized metabolism (R = 0.89; P < .001). In healthy participants and compared with no exposure, 50-minute cell phone exposure was associated with increased brain glucose metabolism in the region closest to the antenna. This finding is of unknown clinical significance.
Impact of chiropractic services at an on-site health center.
Kindermann, Sylvia L; Hou, Qingjiang; Miller, Ross M
2014-09-01
To compare the influence of employer-sponsored, on-site chiropractic care against community-obtained care on health care utilization. This was a retrospective claims analysis of members of a single employee health plan receiving chiropractic care on-site or off-site from 2010 to 2012. Utilization differences were evaluated by having 1 health care event or more, including radiology or clinical visits. There were 876 on-site and 759 off-site participants. The off-site group received more radiology services overall (55.5% vs 38.2%; P < 0.001) including magnetic resonance imaging, ultrasound, and radiograph (all P < 0.0001); had higher outpatient (P < 0.0001) and emergency department (P = 0.022) utilization; and demonstrated greater use of chiropractic care and physical therapy (both P < 0.0001). Compared with off-site care, on-site chiropractic services are associated with lower health care utilization. These results support the value of chiropractic services offered at on-site health centers.
Automatic Strain-Rate Controller,
1976-12-01
D—AO37 9~e2 ROME AIR DEVELOPMENT CENTER GRIFFISS AFB N 1’ FIG 13/ 6AUTOMATIC STRAIN—RATE CONTROLLER, (U) DEC 76 R L HUNTSINGER. J A ADAMSK I...goes to zero. CONTROLLER, Leeds and Northrup Series 80 CAT with proportional band , rate , reset, and approach controls . Input from deviation output...8) through ( 16) . (8) Move the set-point slowl y up to 3 or 4. (9) If the recorder po inter hunts , adjust the func t ion controls on tine Ser
NASA Technical Reports Server (NTRS)
1994-01-01
An aerial color infrared (CIR) mapping system developed by Kennedy Space Center enables Florida's Charlotte County to accurately appraise its citrus groves while reducing appraisal costs. The technology was further advanced by development of a dual video system making it possible to simultaneously view images of the same area and detect changes. An image analysis system automatically surveys and photo interprets grove images as well as automatically counts trees and reports totals. The system, which saves both time and money, has potential beyond citrus grove valuation.
Hülsheger, Ute R; Lang, Jonas W B; Schewe, Anna F; Zijlstra, Fred R H
2015-03-01
We investigated the relationship between deep acting, automatic regulation and customer tips with 2 different study designs. The first study was a daily diary study using a sample of Dutch waiters and taxi-drivers and assessed the link of employees' daily self-reported levels of deep acting and automatic regulation with the amount of tips provided by customers (N = 166 measurement occasions nested in 34 persons). Whereas deep acting refers to deliberate attempts to modify felt emotions and involves conscious effort, automatic regulation refers to automated emotion regulatory processes that result in the natural experience of desired emotions and do not involve deliberate control and effort. Multilevel analyses revealed that both types of emotion regulation were positively associated with customer tips. The second study was an experimental field study using a sample of German hairdressers (N = 41). Emotion regulation in terms of both deep acting and automatic regulation was manipulated using a brief self-training intervention and daily instructions to use cognitive change and attentional deployment. Results revealed that participants in the intervention group received significantly more tips than participants in the control group. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Automatic learning rate adjustment for self-supervising autonomous robot control
NASA Technical Reports Server (NTRS)
Arras, Michael K.; Protzel, Peter W.; Palumbo, Daniel L.
1992-01-01
Described is an application in which an Artificial Neural Network (ANN) controls the positioning of a robot arm with five degrees of freedom by using visual feedback provided by two cameras. This application and the specific ANN model, local liner maps, are based on the work of Ritter, Martinetz, and Schulten. We extended their approach by generating a filtered, average positioning error from the continuous camera feedback and by coupling the learning rate to this error. When the network learns to position the arm, the positioning error decreases and so does the learning rate until the system stabilizes at a minimum error and learning rate. This abolishes the need for a predetermined cooling schedule. The automatic cooling procedure results in a closed loop control with no distinction between a learning phase and a production phase. If the positioning error suddenly starts to increase due to an internal failure such as a broken joint, or an environmental change such as a camera moving, the learning rate increases accordingly. Thus, learning is automatically activated and the network adapts to the new condition after which the error decreases again and learning is 'shut off'. The automatic cooling is therefore a prerequisite for the autonomy and the fault tolerance of the system.
Automated pharmaceutical tablet coating layer evaluation of optical coherence tomography images
NASA Astrophysics Data System (ADS)
Markl, Daniel; Hannesschläger, Günther; Sacher, Stephan; Leitner, Michael; Khinast, Johannes G.; Buchsbaum, Andreas
2015-03-01
Film coating of pharmaceutical tablets is often applied to influence the drug release behaviour. The coating characteristics such as thickness and uniformity are critical quality parameters, which need to be precisely controlled. Optical coherence tomography (OCT) shows not only high potential for off-line quality control of film-coated tablets but also for in-line monitoring of coating processes. However, an in-line quality control tool must be able to determine coating thickness measurements automatically and in real-time. This study proposes an automatic thickness evaluation algorithm for bi-convex tables, which provides about 1000 thickness measurements within 1 s. Beside the segmentation of the coating layer, optical distortions due to refraction of the beam by the air/coating interface are corrected. Moreover, during in-line monitoring the tablets might be in oblique orientation, which needs to be considered in the algorithm design. Experiments were conducted where the tablet was rotated to specified angles. Manual and automatic thickness measurements were compared for varying coating thicknesses, angles of rotations, and beam displacements (i.e. lateral displacement between successive depth scans). The automatic thickness determination algorithm provides highly accurate results up to an angle of rotation of 30°. The computation time was reduced to 0.53 s for 700 thickness measurements by introducing feasibility constraints in the algorithm.
Review of AIDS development. [airborne computers for reliability engineering
NASA Technical Reports Server (NTRS)
Vermeulen, H. C.; Danielsson, S. G.
1981-01-01
The operation and implementation of the aircraft integrated data system AIDS are described. The system is described as an engineering tool with strong emphasis on analysis of recorded information. The AIDS is primarily directed to the monitoring of parameters related to: the safety of the flight; the performance of the aircraft; the performance of the flight guidance system; and the performance and condition of the engines. The system provide short term trend analysis on a trend chart that is updated by the flight engineer on every flight that lasts more than 4 flight hours. Engine data prints are automatically presented during take-off and in the case of limit excedance, e.g., the print shows an automatically reported impending hotstarts on engine nr. 1. Other significant features are reported.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
... automatic shutoff system for the center and auxiliary tank fuel boost pumps, as applicable, and installing a placard in the airplane flight deck if necessary; replacing the P5-2 fuel system module assembly; and installing the un-commanded on (UCO) protection system for the center and auxiliary tank fuel boost pumps, as...
ERIC Educational Resources Information Center
Lifer, Charles W.; And Others
This report presents a study undertaken to evaluate the effectiveness of contacting previously unreached urban audiences through the use of films at automatic self-learning centers. To accomplish this, the study attempted to determine: (1) the extent to which people in an urban business (a large insurance company) would look at agricultural films…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... public comment period and thereby grants an automatic 30-day extension to the normal 45-day public... square-foot convention center; 28,100 square-foot entertainment center; 3,400 garage and surface parking... the exception of the hotel and parking garage which would have a height of up to five stories above...
2003-10-27
KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, Eric Madaras (left), NASA-Langley Research Center, and Jim McGee, The Boeing Company, Huntington Beach, Calif., conduct impulse tests on the right wing leading edge (WLE) of Space Shuttle Endeavour. The tests monitor how sound impulses propagate through the WLE area. The data collected will be analyzed to explore the possibility of adding new instrumentation to the wing that could automatically detect debris or micrometeroid impacts on the Shuttle while in flight. The study is part of the initiative ongoing at KSC and around the agency to return the orbiter fleet to flight status.
Gill, John S; Rose, Caren; Joffres, Yayuk; Landsberg, David; Gill, Jagbir
2018-05-01
The impact of dialysis exposure before nonpreemptive living donor kidney transplantation on allograft outcomes is uncertain. Retrospective cohort study. Adult first-time recipients of kidney-only living donor transplants in the United States who were recorded within the Scientific Registry of Transplant Recipients for 2000 to 2016. Duration of pretransplantation dialysis exposure. Kidney transplant failure from any cause including death, death-censored transplant failure, and death with allograft function. Among the 77,607 living donor transplant recipients studied, longer pretransplantation dialysis exposure was independently associated with progressively higher risk for transplant failure from any cause, including death beginning 6 months after transplantation. Compared with patients with 0.1 to 3.0 months of dialysis exposure, the HR for transplant failure from any cause including death increased from 1.16 (95% CI, 1.07-1.31) among patients with 6.1 to 9.0 months of dialysis exposure to 1.60 (95% CI, 1.43-1.79) among patients with more than 60.0 months of dialysis exposure. Pretransplantation dialysis exposure varied markedly among centers; median exposures were 11.0 and 18.9 months for centers in the 10th and 90th percentiles of dialysis exposure, respectively. Centers with the highest proportions of living donor transplantations had the shortest pretransplantation dialysis exposures. In multivariable analysis, patients of black race, with low income, with nonprivate insurance, with less than high school education, and not working for income had longer pretransplantation dialysis exposures. Dialysis exposure in patients with these characteristics also varied 2-fold between transplantation centers. Why longer dialysis exposure is associated with transplant failure could not be determined. Longer pretransplantation dialysis exposure in nonpreemptive living donor kidney transplantation is associated with increased risk for allograft failure. Pretransplantation dialysis exposure is associated with recipients' sociodemographic and transplantation centers' characteristics. Understanding whether limiting pretransplantation dialysis exposure could improve living donor transplant outcomes will require further study. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Van De Gucht, Tim; Saeys, Wouter; Van Meensel, Jef; Van Nuffel, Annelies; Vangeyte, Jurgen; Lauwers, Ludwig
2018-01-01
Although prototypes of automatic lameness detection systems for dairy cattle exist, information about their economic value is lacking. In this paper, a conceptual and operational framework for simulating the farm-specific economic value of automatic lameness detection systems was developed and tested on 4 system types: walkover pressure plates, walkover pressure mats, camera systems, and accelerometers. The conceptual framework maps essential factors that determine economic value (e.g., lameness prevalence, incidence and duration, lameness costs, detection performance, and their relationships). The operational simulation model links treatment costs and avoided losses with detection results and farm-specific information, such as herd size and lameness status. Results show that detection performance, herd size, discount rate, and system lifespan have a large influence on economic value. In addition, lameness prevalence influences the economic value, stressing the importance of an adequate prior estimation of the on-farm prevalence. The simulations provide first estimates for the upper limits for purchase prices of automatic detection systems. The framework allowed for identification of knowledge gaps obstructing more accurate economic value estimation. These include insights in cost reductions due to early detection and treatment, and links between specific lameness causes and their related losses. Because this model provides insight in the trade-offs between automatic detection systems' performance and investment price, it is a valuable tool to guide future research and developments. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Murakami, Michio; Ono, Kyoko; Tsubokura, Masaharu; Nomura, Shuhei; Oikawa, Tomoyoshi; Oka, Tosihiro; Kami, Masahiro; Oki, Taikan
2015-01-01
After the 2011 accident at the Fukushima Daiichi nuclear power plant, nursing-home residents and staff were evacuated voluntarily from damaged areas to avoid radiation exposure. Unfortunately, the evacuation resulted in increased mortalities among nursing home residents. We assessed the risk trade-off between evacuation and radiation for 191 residents and 184 staff at three nursing homes by using the same detriment indicator, namely loss of life expectancy (LLE), under four scenarios, i.e. "rapid evacuation (in accordance with the actual situation; i.e. evacuation on 22 March)," "deliberate evacuation (i.e. evacuation on 20 June)," "20-mSv exposure," and "100-mSv exposure." The LLE from evacuation-related mortality among nursing home residents was assessed with survival probability data from nursing homes in the city of Minamisoma and the city of Soma. The LLE from radiation mortality was calculated from the estimated age-specific mortality rates from leukemia and all solid cancers based on the additional effective doses and the survival probabilities. The total LLE of residents due to evacuation-related risks in rapid evacuation was 11,000 persons-d-much higher than the total LLEs of residents and staff due to radiation in the other scenarios (27, 1100, and 5800 persons-d for deliberate evacuation, 20 mSv-exposure, and 100 mSv-exposure, respectively). The latitude for reducing evacuation risks among nursing home residents is surprisingly large. Evacuation regulation and planning should therefore be well balanced with the trade-offs against radiation risks. This is the first quantitative assessment of the risk trade-off between radiation exposure and evacuation after a nuclear power plant accident.
Satellite freeze forecast system. Operating/troubleshooting manual
NASA Technical Reports Server (NTRS)
Martsolf, J. D. (Principal Investigator)
1983-01-01
Examples of operational procedures are given to assist users of the satellites freeze forecasting system (SFFS) in logging in on to the computer, executing the programs in the menu, logging off the computer, and setting up the automatic system. Directions are also given for displaying, acquiring, and listing satellite maps; for communicating via terminal and monitor displays; and for what to do when the SFFS doesn't work. Administrative procedures are included.
Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva
2017-06-01
The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.
Dermal exposure and urinary 1-hydroxypyrene among asphalt roofing workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClean, M.D.; Rinehart, R.D.; Sapkota, A.
2007-07-01
The primary objective of this study was to identify significant determinants of dermal exposure to polycyclic aromatic compounds (PACs) among asphalt roofing workers and use urinary 1-hydroxyprene (1-OHP) measurements to evaluate the effect of dermal exposure on total absorbed dose. The study population included 26 asphalt roofing workers who performed three primary tasks: tearing off old roofs, putting down new roofs, and operating the kettle at ground level. During multiple consecutive work shifts, dermal patch samples were collected from the underside of each worker's wrists and were analyzed for PACs, pyrene, and benzo(a)pyrene (BAP). During the same work week, urinemore » samples were collected at pre-shift, post-shift, and bedtime each day and were analyzed for 1-OHP (205 urine samples). Linear mixed effects models were used to evaluate the dermal measurements for the purpose of identifying important determinants of exposure, and to evaluate urinary 1-OHP measurements for the purpose of identifying important determinants of total absorbed dose. Dermal exposures to PAC, pyrene, and BAP were found to vary significantly by roofing task and by the presence of an old coal tar pitch roof. For each of the three analytes, the adjusted mean dermal exposures associated with tear-off were approximately four times higher than exposures associated with operating the kettle. Exposure to coal tar pitch was associated with a 6-fold increase in PAC exposure, an 8-fold increase in pyrene exposure and a 35-fold increase in BAP exposure. The presence of coal tar pitch was the primary determinant of dermal exposure, particularly for exposure to BAP. However, the task-based differences that were observed while controlling for pitch suggest that exposure to asphalt also contributes to dermal exposures.« less
Monteiro, Vaneska Barbosa; Silva, Vanessa Farias; Lima, Debora Barbosa; Guedes, Raul Narciso Carvalho; Gondim, Manoel Guedes Correa
2018-06-01
An understanding of the causes and consequences of dispersal is vital for managing populations. Environmental contaminants, such as pesticides, provide potential environmental context-dependent stimuli for dispersal of targeted and non-targeted species, which may occur not only for active but also for passive dispersal, although such a possibility is frequently neglected. Here, we assessed the potential of food deprivation and acaricides to interfere with the take-off for passive (wind) dispersal of the predatory mite Neoseiulus baraki. Wind tunnel bioassays indicated that starvation favoured the take-off for wind dispersal by the mite predator, which also varied with wind velocity, and dispersal increased at higher velocities within the 1-7 (m s -1 ) range tested. For the acaricides tested, particularly the biopesticide azadirachtin but also abamectin and fenpyroximate, the rate of predator take-off for dispersal increased, and further increased with wind velocity up to 7 m/s. Such responses were associated with changes in the predator behavioural preparation for wind-mediated passive dispersal, with a greater incidence of the standing posture that permitted take-off. The rate of take-off for passive dispersal by N. baraki increased with food deprivation and exposure to the residues of agricultural acaricides. Azadirachtin exposure resulted in a particularly strong response, although abamectin and fenpyroximate also stimulated dispersal. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Marin, Diego; Gegundez-Arias, Manuel E; Suero, Angel; Bravo, Jose M
2015-02-01
Development of automatic retinal disease diagnosis systems based on retinal image computer analysis can provide remarkably quicker screening programs for early detection. Such systems are mainly focused on the detection of the earliest ophthalmic signs of illness and require previous identification of fundal landmark features such as optic disc (OD), fovea or blood vessels. A methodology for accurate center-position location and OD retinal region segmentation on digital fundus images is presented in this paper. The methodology performs a set of iterative opening-closing morphological operations on the original retinography intensity channel to produce a bright region-enhanced image. Taking blood vessel confluence at the OD into account, a 2-step automatic thresholding procedure is then applied to obtain a reduced region of interest, where the center and the OD pixel region are finally obtained by performing the circular Hough transform on a set of OD boundary candidates generated through the application of the Prewitt edge detector. The methodology was evaluated on 1200 and 1748 fundus images from the publicly available MESSIDOR and MESSIDOR-2 databases, acquired from diabetic patients and thus being clinical cases of interest within the framework of automated diagnosis of retinal diseases associated to diabetes mellitus. This methodology proved highly accurate in OD-center location: average Euclidean distance between the methodology-provided and actual OD-center position was 6.08, 9.22 and 9.72 pixels for retinas of 910, 1380 and 1455 pixels in size, respectively. On the other hand, OD segmentation evaluation was performed in terms of Jaccard and Dice coefficients, as well as the mean average distance between estimated and actual OD boundaries. Comparison with the results reported by other reviewed OD segmentation methodologies shows our proposal renders better overall performance. Its effectiveness and robustness make this proposed automated OD location and segmentation method a suitable tool to be integrated into a complete prescreening system for early diagnosis of retinal diseases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
ERIC Educational Resources Information Center
Poitras, Adrian W., Ed.
1973-01-01
The following items are discussed: Digital Counters and Readout Devices, Automatic Burette Outfits, Noise Exposure System, Helium-Cadmium Laser, New pH Buffers and Flip-Top Dispenser, Voltage Calibrator Transfer Standard, Photomicrographic Stereo Zoom Microscope, Portable pH Meter, Micromanipulators, The Snuffer, Electronic Top-Loading Balances,…
Automatic calibration method for plenoptic camera
NASA Astrophysics Data System (ADS)
Luan, Yinsen; He, Xing; Xu, Bing; Yang, Ping; Tang, Guomao
2016-04-01
An automatic calibration method is proposed for a microlens-based plenoptic camera. First, all microlens images on the white image are searched and recognized automatically based on digital morphology. Then, the center points of microlens images are rearranged according to their relative position relationships. Consequently, the microlens images are located, i.e., the plenoptic camera is calibrated without the prior knowledge of camera parameters. Furthermore, this method is appropriate for all types of microlens-based plenoptic cameras, even the multifocus plenoptic camera, the plenoptic camera with arbitrarily arranged microlenses, or the plenoptic camera with different sizes of microlenses. Finally, we verify our method by the raw data of Lytro. The experiments show that our method has higher intelligence than the methods published before.
NASA Astrophysics Data System (ADS)
Goel, Anju; Kumar, Prashant
2015-04-01
Quantification of disproportionate contribution made by signalised traffic intersections (TIs) to overall daily commuting exposure is important but barely known. We carried out mobile measurements in a car for size-resolved particle number concentrations (PNCs) in the 5-560 nm range under five different ventilation settings on a 6 km long busy round route with 10 TIs. These ventilation settings were windows fully open and both outdoor air intake from fan and heating off (Set1), windows closed, fan 25% on and heating 50% on (Set2), windows closed, fan 100% on and heating off (Set3), windows closed, fan off and heating 100% on (Set4), and windows closed, fan and heating off (Set5). Measurements were taken sequentially inside and outside the car cabin at 10 Hz sampling rate using a solenoid switching system in conjunction with a fast response differential mobility spectrometer (DMS50). The objectives were to: (i) identify traffic conditions under which TIs becomes hot-spots of PNCs, (ii) assess the effect of ventilation settings in free-flow and delay conditions (waiting time at a TI when traffic signal is red) on in-cabin PNCs with respect to on-road PNCs at TIs, (iii) deriving the relationship between the PNCs and change in driving speed during delay time at the TIs, and (iv) quantify the contribution of exposure at TIs with respect to overall commuting exposure. Congested TIs were found to become hot-spots when vehicle accelerate from idling conditions. In-cabin peak PNCs followed similar temporal trend as for on-road peak PNCs. Reduction in in-cabin PNC with respect to outside PNC was highest (70%) during free-flow traffic conditions when both fan drawing outdoor air into the cabin and heating was switched off. Such a reduction in in-cabin PNCs at TIs was highest (88%) with respect to outside PNC during delay conditions when fan was drawing outside air at 25% on and heating was 50% on settings. PNCs and change in driving speed showed an exponential-fit relationship during the delay events at TIs. Short-term exposure for ∼2% of total commuting time in car corresponded to ∼25% of total respiratory doses. This study highlights a need for more studies covering diverse traffic and geographical conditions in urban environments so that the disparate contribution of exposure at TIs can be quantified.
NASA Technical Reports Server (NTRS)
Thompson, J. A.
1977-01-01
Lightweight device automatically alines stainless-steel tubing and fittings, regardless of differing diameters, prior to joining via induction brazing. Device is useful in remote areas where existing supports or walls cannot be used to anchor tubing holder.
Image/text automatic indexing and retrieval system using context vector approach
NASA Astrophysics Data System (ADS)
Qing, Kent P.; Caid, William R.; Ren, Clara Z.; McCabe, Patrick
1995-11-01
Thousands of documents and images are generated daily both on and off line on the information superhighway and other media. Storage technology has improved rapidly to handle these data but indexing this information is becoming very costly. HNC Software Inc. has developed a technology for automatic indexing and retrieval of free text and images. This technique is demonstrated and is based on the concept of `context vectors' which encode a succinct representation of the associated text and features of sub-image. In this paper, we will describe the Automated Librarian System which was designed for free text indexing and the Image Content Addressable Retrieval System (ICARS) which extends the technique from the text domain into the image domain. Both systems have the ability to automatically assign indices for a new document and/or image based on the content similarities in the database. ICARS also has the capability to retrieve images based on similarity of content using index terms, text description, and user-generated images as a query without performing segmentation or object recognition.
Pulse-Echo Ultrasonic Imaging Method for Eliminating Sample Thickness Variation Effects
NASA Technical Reports Server (NTRS)
Roth, Don J. (Inventor)
1997-01-01
A pulse-echo, immersion method for ultrasonic evaluation of a material which accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer and automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjustments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.
PHASEGO: A toolkit for automatic calculation and plot of phase diagram
NASA Astrophysics Data System (ADS)
Liu, Zhong-Li
2015-06-01
The PHASEGO package extracts the Helmholtz free energy from the phonon density of states obtained by the first-principles calculations. With the help of equation of states fitting, it reduces the Gibbs free energy as a function of pressure/temperature at fixed temperature/pressure. Based on the quasi-harmonic approximation (QHA), it calculates the possible phase boundaries among all the structures of interest and finally plots the phase diagram automatically. For the single phase analysis, PHASEGO can numerically derive many properties, such as the thermal expansion coefficients, the bulk moduli, the heat capacities, the thermal pressures, the Hugoniot pressure-volume-temperature relations, the Grüneisen parameters, and the Debye temperatures. In order to check its ability of phase transition analysis, I present here two examples: semiconductor GaN and metallic Fe. In the case of GaN, PHASEGO automatically determined and plotted the phase boundaries among the provided zinc blende (ZB), wurtzite (WZ) and rocksalt (RS) structures. In the case of Fe, the results indicate that at high temperature the electronic thermal excitation free energy corrections considerably alter the phase boundaries among the body-centered cubic (bcc), face-centered cubic (fcc) and hexagonal close-packed (hcp) structures.
Design of automatic startup and shutdown logic for a Brayton-cycle 2- to 15-kilowatt engine
NASA Technical Reports Server (NTRS)
Vrancik, J. E.; Bainbridge, R. C.
1975-01-01
The NASA Lewis Research Center is conducting a closed-Brayton-cycle power conversion system technology program in which a complete power system (engine) has been designed and demonstrated. This report discusses the design of automatic startup and shutdown logic circuits as a modification to the control system presently used in this demonstration engine. This modification was primarily intended to make starting the engine as simple and safe as possible and to allow the engine to be run unattended. In the modified configuration the engine is started by turning the control console power on and pushing the start button after preheating the gas loop. No other operator action is required to effect a complete startup. Shutdown, if one is required, is also effected by a simple stop button. The automatic startup and shutdown of the engine have been successfully and purposefully demonstrated more than 50 times at the Lewis Research Center during 10,000 hours of unattended operation. The net effect of this modification is an engine that can be safely started and stopped by relatively untrained personnel. The approach lends itself directly to remote unattended operation.
NASA Astrophysics Data System (ADS)
Erickson, M.; Olaguer, J.; Wijesinghe, A.; Colvin, J.; Neish, B.; Williams, J.
2014-12-01
It is becoming increasingly important to understand the emissions and health effects of industrial facilities. Many areas have no or limited sustained monitoring capabilities, making it difficult to quantify the major pollution sources affecting human health, especially in fence line communities. Developments in real-time monitoring and micro-scale modeling offer unique ways to tackle these complex issues. This presentation will demonstrate the capability of coupling real-time observations with micro-scale modeling to provide real-time information and near real-time source attribution. The Houston Advanced Research Center constructed the Mobile Acquisition of Real-time Concentrations (MARC) laboratory. MARC consists of a Ford E-350 passenger van outfitted with a Proton Transfer Reaction Mass Spectrometer (PTR-MS) and meteorological equipment. This allows for the fast measurement of various VOCs important to air quality. The data recorded from the van is uploaded to an off-site database and the information is broadcast to a website in real-time. This provides for off-site monitoring of MARC's observations, which allows off-site personnel to provide immediate input to the MARC operators on how to best achieve project objectives. The information stored in the database can also be used to provide near real-time source attribution. An inverse model has been used to ascertain the amount, location, and timing of emissions based on MARC measurements in the vicinity of industrial sites. The inverse model is based on a 3D micro-scale Eulerian forward and adjoint air quality model known as the HARC model. The HARC model uses output from the Quick Urban and Industrial Complex (QUIC) wind model and requires a 3D digital model of the monitored facility based on lidar or industrial permit data. MARC is one of the instrument platforms deployed during the 2014 Benzene and other Toxics Exposure Study (BEE-TEX) in Houston, TX. The main goal of the study is to quantify and explain the origin of ambient exposure to hazardous air pollutants in an industrial fence line community near the Houston Ship Channel. Preliminary results derived from analysis of MARC observations during the BEE-TEX experiment will be presented.
In situ control of cardiotomy suction reduces blood trauma.
Tevaearai, H T; Mueller, X M; Horisberger, J; Augstburger, M; Bock, H; Knorr, A; von Segesser, L K
1998-01-01
Cardiotomy suction is known for its deleterious effects on formed and unformed blood elements. The authors investigated an "intelligent" remote controlled automatic suction system. A suction cannula with an optic sensor at its tip was connected to a special closed cardiotomy reservoir. Contact with blood immediately generated a reservoir vacuum from 0 to -100 mmHg, permitting aspiration until the blood was no longer detected (automatic shut off). Blood trauma was evaluated in a bovine model, comparing the automatic suction system vs standard continuous aspiration (control) adjusted to -100 mmHg. After full systemic heparinization, five calves (weight, 62.5 +/- 4.4 kg) for the automatic suction system group, and four (weight, 62.8 +/- 5.1 kg) for the control group, were equipped with a jugular cannula connected via a roller pump to the cardiotomy reservoir. Through a small thoracotomy, a standardized hole was created in the right atrium, allowing for a blood loss of approximately 400 ml/min. The suction cannula was placed into the chest cavity in a fixed position. Blood samples were drawn at regular intervals for cell count and chemistry. Lactate dehydrogenase values, for the automatic suction system and the control groups, respectively, expressed as percent of baseline value, were 88 +/- 14 vs 116 +/- 22 after 1 hr; 94 +/- 16 vs 123 +/- 23 after 2 hr; and 97 +/- 19 vs 140 +/- 48 after 3 hr (p < 0.05). Values for free hemoglobin in plasma (percent of baseline value), for the automatic suction system and the control groups, respectively, were 102 +/- 18 vs 200 +/- 69 after 1 hr; 98 +/- 29 vs 163 +/- 37 after 2 hr; and 94 +/- 37 vs 179 +/- 42 after 3 hr (p < 0.05). Compared with a standard continuous aspiration system, in situ regulation of suction significantly reduces blood trauma.
A training approach to improve stepping automaticity while dual-tasking in Parkinson's disease
Chomiak, Taylor; Watts, Alexander; Meyer, Nicole; Pereira, Fernando V.; Hu, Bin
2017-01-01
Abstract Background: Deficits in motor movement automaticity in Parkinson's disease (PD), especially during multitasking, are early and consistent hallmarks of cognitive function decline, which increases fall risk and reduces quality of life. This study aimed to test the feasibility and potential efficacy of a wearable sensor-enabled technological platform designed for an in-home music-contingent stepping-in-place (SIP) training program to improve step automaticity during dual-tasking (DT). Methods: This was a 4-week prospective intervention pilot study. The intervention uses a sensor system and algorithm that runs off the iPod Touch which calculates step height (SH) in real-time. These measurements were then used to trigger auditory (treatment group, music; control group, radio podcast) playback in real-time through wireless headphones upon maintenance of repeated large amplitude stepping. With small steps or shuffling, auditory playback stops, thus allowing participants to use anticipatory motor control to regain positive feedback. Eleven participants were recruited from an ongoing trial (Trial Number: ISRCTN06023392). Fear of falling (FES-I), general cognitive functioning (MoCA), self-reported freezing of gait (FOG-Q), and DT step automaticity were evaluated. Results: While we found no significant effect of training on FES-I, MoCA, or FOG-Q, we did observe a significant group (music vs podcast) by training interaction in DT step automaticity (P<0.01). Conclusion: Wearable device technology can be used to enable musically-contingent SIP training to increase motor automaticity for people living with PD. The training approach described here can be implemented at home to meet the growing demand for self-management of symptoms by patients. PMID:28151878
Code of Federal Regulations, 2011 CFR
2011-01-01
... of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE CONDUCT ON U.S. MEAT ANIMAL RESEARCH CENTER, CLAY CENTER, NEBRASKA § 501.2 Admission. Admission to the Research Center during “off duty” hours shall be restricted to the main arteries and any deviation...
Code of Federal Regulations, 2014 CFR
2014-01-01
... of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE CONDUCT ON U.S. MEAT ANIMAL RESEARCH CENTER, CLAY CENTER, NEBRASKA § 501.2 Admission. Admission to the Research Center during “off duty” hours shall be restricted to the main arteries and any deviation...
Code of Federal Regulations, 2013 CFR
2013-01-01
... of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE CONDUCT ON U.S. MEAT ANIMAL RESEARCH CENTER, CLAY CENTER, NEBRASKA § 501.2 Admission. Admission to the Research Center during “off duty” hours shall be restricted to the main arteries and any deviation...
Code of Federal Regulations, 2012 CFR
2012-01-01
... of the Department of Agriculture (Continued) AGRICULTURAL RESEARCH SERVICE, DEPARTMENT OF AGRICULTURE CONDUCT ON U.S. MEAT ANIMAL RESEARCH CENTER, CLAY CENTER, NEBRASKA § 501.2 Admission. Admission to the Research Center during “off duty” hours shall be restricted to the main arteries and any deviation...
Intussusception reduction: Effect of air vs. liquid enema on radiation dose.
Kaplan, Summer L; Magill, Dennise; Felice, Marc A; Edgar, J Christopher; Anupindi, Sudha A; Zhu, Xiaowei
2017-10-01
Both air and radiopaque liquid contrast are used to reduce ileocolic intussusception under fluoroscopy. Some suggest air lowers radiation dose due to shorter procedure times. However, air enema likely lowers radiation dose regardless of fluoroscopy time due to less density over the automatic exposure control cells. We test the hypothesis that air enema reduction of ileocolic intussusception results in lower radiation dose than liquid contrast enema independent of fluoroscopy time. We describe a role for automatic exposure control in this dose difference. We retrospectively evaluated air and liquid intussusception reductions performed on a single digital fluoroscopic unit during a 26-month period. We compared patient age, weight, gender, exam time of day and year, performing radiologist(s), radiographic image acquisitions, grid and magnification use, fluoroscopy time and dose area product. We compared categorical and continuous variables statistically using chi-square and Mann-Whitney U tests, respectively. The mean dose area product was 2.7-fold lower for air enema, 1.3 ± 0.9 dGy·cm 2 , than for liquid, 3.5 ± 2.5 dGy·cm 2 (P<0.005). The mean fluoroscopy time was similar between techniques. The mean dose area product/min was 2.3-fold lower for air, 0.6 ± 0.2 dGy·cm 2 /min, than for liquid, 1.4 ± 0.5 dGy·cm 2 /min (P<0.001). No group differences were identified in other measured dose parameters. Fluoroscopic intussusception reduction using air enema uses less than half the radiation dose of liquid contrast enema. Dose savings are independent of fluoroscopy time and are likely due to automatic exposure control interaction.
Favazza, Christopher P.; Yu, Lifeng; Leng, Shuai; Kofler, James M.; McCollough, Cynthia H.
2015-01-01
Objective To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. Materials and Methods A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. Results For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise–based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Conclusions Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects. PMID:25938214